  1. Can envelope codes reduce electricity and CO2 emissions in different types of buildings in the hot climate of Bahrain?

    International Nuclear Information System (INIS)

    Radhi, H.

    2009-01-01

    The depletion of non-renewable resources and the environmental impact of energy consumption, particularly energy use in buildings, have awakened considerable interest in energy efficiency. Building energy codes have recently become effective techniques to achieve efficiency targets. The Electricity and Water Authority in Bahrain has set a target of 40% reduction of building electricity consumption and CO 2 emissions to be achieved by using envelope thermal insulation codes. This paper investigates the ability of the current codes to achieve such a benchmark and evaluates their impact on building energy consumption. The results of a simulation study are employed to investigate the impact of the Bahraini codes on the energy and environmental performance of buildings. The study focuses on air-conditioned commercial buildings and concludes that envelope codes, at best, are likely to reduce the energy use of the commercial sector by 25% if the building envelope is well-insulated and efficient glazing is used. Bahraini net CO 2 emissions could drop to around 7.1%. The simulation results show that the current energy codes alone are not sufficient to achieve a 40% reduction benchmark, and therefore, more effort should be spent on moving towards a more comprehensive approach

  2. Code of Ethics for Electrical Engineers

    Science.gov (United States)

    Matsuki, Junya

    The Institute of Electrical Engineers of Japan (IEEJ) has established the rules of practice for its members recently, based on its code of ethics enacted in 1998. In this paper, first, the characteristics of the IEEJ 1998 ethical code are explained in detail compared to the other ethical codes for other fields of engineering. Secondly, the contents which shall be included in the modern code of ethics for electrical engineers are discussed. Thirdly, the newly-established rules of practice and the modified code of ethics are presented. Finally, results of questionnaires on the new ethical code and rules which were answered on May 23, 2007, by 51 electrical and electronic students of the University of Fukui are shown.

  3. Electrical safety code manual a plan language guide to national electrical code, OSHA and NFPA 70E

    CERN Document Server

    Keller, Kimberley

    2010-01-01

    Safety in any workplace is extremely important. In the case of the electrical industry, safety is critical and the codes and regulations which determine safe practices are both diverse and complicated. Employers, electricians, electrical system designers, inspectors, engineers and architects must comply with safety standards listed in the National Electrical Code, OSHA and NFPA 70E. Unfortunately, the publications which list these safety requirements are written in very technically advanced terms and the average person has an extremely difficult time understanding exactly what they need to

  4. Electrical, instrumentation, and control codes and standards

    International Nuclear Information System (INIS)

    Kranning, A.N.

    1978-01-01

    During recent years numerous documents in the form of codes and standards have been developed and published to provide design, fabrication and construction rules and criteria applicable to instrumentation, control and power distribution facilities for nuclear power plants. The contents of this LTR were prepared by NUS Corporation under Subcontract K5108 and provide a consolidated index and listing of the documents selected for their application to procurement of materials and design of modifications and new construction at the LOFT facility. These codes and standards should be applied together with the National Electrical Code, the ID Engineering Standards and LOFT Specifications to all LOFT instrument and electrical design activities

  5. Italian electricity supply contracts optimization: ECO computer code

    International Nuclear Information System (INIS)

    Napoli, G.; Savelli, D.

    1993-01-01

    The ECO (Electrical Contract Optimization) code written in the Microsoft WINDOWS 3.1 language can be handled with a 286 PC and a minimum of RAM. It consists of four modules, one for the calculation of ENEL (Italian National Electricity Board) tariffs, one for contractual time-of-use tariffs optimization, a table of tariff coefficients, and a module for monthly power consumption calculations based on annual load diagrams. The optimization code was developed by ENEA (Italian Agency for New Technology, Energy and the Environment) to help Italian industrial firms comply with new and complex national electricity supply contractual regulations and tariffs. In addition to helping industrial firms determine optimum contractual arrangements, the code also assists them in optimizing their choice of equipment and production cycles

  6. DEVELOPMENT OF SALES APPLICATION OF PREPAID ELECTRICITY VOUCHER BASED ON ANFROID PLATFORM USING QUICK RESPONSE CODE (QR CODE

    Directory of Open Access Journals (Sweden)

    Ricky Akbar

    2017-09-01

    Full Text Available Perusahaan Listrik Negara (PLN has implemented a smart electricity system or prepaid electricity. The customers pay the electricity voucher first before use the electricity. The token contained in electricity voucher that has been purchased by the customer is inserted into the Meter Prabayar (MPB installed in the location of customers. When a customer purchases a voucher, it will get a receipt that contains all of the customer's identity and the 20-digit of voucher code (token to be entered into MPB as a substitute for electrical energy credit. Receipts obtained by the customer is certainly vulnerable to loss, or hijacked by unresponsible parties. In this study, authors designed and develop an android based application by utilizing QR code technology as a replacement for the receipt of prepaid electricity credit which contains the identity of the customer and the 20-digit voucher code. The application is developed by implemented waterfall methodology. The implementation process of the waterfall methods used, are (1 analysis of functional requirement of the system by conducting a preliminary study and data collection based on field studies and literature, (2 system design by using UML diagrams and Business Process Model Notation (BPMN and Entity Relationship diagram (ERD, (3 design implementation by using OOP (Object Oriented programming technique. Web application is developed by using laravel PHP framework and database MySQL while mobile application is developed by using B4A (4 developed system is tested by using blackbox method testing. Final result of this research is a Web and mobile applications for the sale of electricityvoucher by QR Code technology.

  7. Learning to REDUCE: A Reduced Electricity Consumption Prediction Ensemble

    Energy Technology Data Exchange (ETDEWEB)

    Aman, Saima; Chelmis, Charalampos; Prasanna, Viktor

    2016-02-12

    Utilities use Demand Response (DR) to balance supply and demand in the electric grid by involving customers in efforts to reduce electricity consumption during peak periods. To implement and adapt DR under dynamically changing conditions of the grid, reliable prediction of reduced consumption is critical. However, despite the wealth of research on electricity consumption prediction and DR being long in practice, the problem of reduced consumption prediction remains largely un-addressed. In this paper, we identify unique computational challenges associated with the prediction of reduced consumption and contrast this to that of normal consumption and DR baseline prediction.We propose a novel ensemble model that leverages different sequences of daily electricity consumption on DR event days as well as contextual attributes for reduced consumption prediction. We demonstrate the success of our model on a large, real-world, high resolution dataset from a university microgrid comprising of over 950 DR events across a diverse set of 32 buildings. Our model achieves an average error of 13.5%, an 8.8% improvement over the baseline. Our work is particularly relevant for buildings where electricity consumption is not tied to strict schedules. Our results and insights should prove useful to the researchers and practitioners working in the sustainable energy domain.

  8. A finite element code for electric motor design

    Science.gov (United States)

    Campbell, C. Warren

    1994-01-01

    FEMOT is a finite element program for solving the nonlinear magnetostatic problem. This version uses nonlinear, Newton first order elements. The code can be used for electric motor design and analysis. FEMOT can be embedded within an optimization code that will vary nodal coordinates to optimize the motor design. The output from FEMOT can be used to determine motor back EMF, torque, cogging, and magnet saturation. It will run on a PC and will be available to anyone who wants to use it.

  9. Comparison of the General Electric BWR/6 standard plant design to the IAEA NUSS codes and guides

    International Nuclear Information System (INIS)

    D'Ardenne, W.H.; Sherwood, G.G.

    1985-01-01

    The General Electric BWR/6 Mark III standard plant design meets or exceeds current requirements of published International Atomic Energy Agency (IAEA) Nuclear Safety Standards (NUSS) codes and guides. This conclusion is based on a review of the NUSS codes and guides by General Electric and by the co-ordinated US review of the NUSS codes and guides during their development. General Electric compared the published IAEA NUSS codes and guides with the General Electric design. The applicability of each code and guide to the BWR/6 Mark III standard plant design was determined. Each code or guide was reviewed by a General Electric engineer knowledgeable about the structures, systems and components addressed and the technical area covered by that code or guide. The results of this review show that the BWR/6 Mark III standard plant design meets or exceeds the applicable requirements of the published IAEA NUSS codes and guides. The co-ordinated US review of the IAEA NUSS codes and guides corroborates the General Electric review. In the co-ordinated US review, the USNRC and US industry organizations (including General Electric) review the NUSS codes and guides during their development. This review ensures that the NUSS codes and guides are consistent with the current US government regulations, guidance and regulatory practices, US voluntary industry codes and standards, and accepted US industry design, construction and operational practices. If any inconsistencies are identified, comments are submitted to the IAEA by the USNRC. All US concerns submitted to the IAEA have been resolved. General Electric design reviews and the Final Design Approval (FDA) issued by the USNRC have verified that the General Electric BWR/6 Mark III standard plant design meets or exceeds the current US requirements, guidance and practices. Since these requirements, guidance and practices meet or exceed those of the NUSS codes and guides, so does the General Electric design. (author)

  10. Section 60 revisited (The Ontario Electrical Safety Code)

    Energy Technology Data Exchange (ETDEWEB)

    Olechna, T.

    2003-06-01

    Recent changes to the Ontario Electrical Safety Code (OESC), specifically the deletion of Section 60, Electrical Communication Systems, are discussed in an effort to explain the history behind the decision and the time frame of the changes. Communication systems include telephone, telegraph, data communications, intercommunications, wired music and paging systems. In brief, the deletion of Section 60 occurred in 1983, and resulted from the fact that communication-type wiring was historically the property of the communications utility and under federal jurisdiction. Since such equipment was under federal jurisdiction, they were not inspected in Ontario, hence the deletion of Section 60 from the Ontario Code. It should be noted that although Section 60 is deleted, a number of rules applicable to communications circuits are spread throughout various sections of the Code, notably in Rule 1-032 dealing with damage and interference, Rule 4-022 involving harmonics issues, Rule 12-904(2) regulates the use of conductors that are of different sources of voltage, and Rule 10-708 which specifies the spacing and bonding requirements for communications systems. The end result is that even though Section 60 was deleted, there are these and other rules in the OESC that have direct impact on communications circuits and in effect help to protect the integrity of the system.

  11. RCC-E a Design Code for I and C and Electrical Systems

    International Nuclear Information System (INIS)

    Haure, J.M.

    2015-01-01

    The paper deals with the stakes and strength of the RCC-E code applicable to Electrical and Instrumentation and control systems and components as regards dealing with safety class functions. The document is interlacing specifications between Owners, safety authorities, designers, and suppliers IAEA safety guides and IEC standards. The code is periodically updated and published by French Society for Design and Construction rules for Nuclear Island Components (AFCEN). The code is compliant with third generation PWR nuclear islands and aims to suit with national regulations as needed in a companion document. The Feedback experience of Fukushima and the licensing of UKEPR in the framework of Generic Design Assessment are lessons learnt that should be considered in the upgrading of the code. The code gathers a set of requirements and relevant good practices of several PWR design and construction practices related to the electrical and I and C systems and components, and electrical engineering documents dealing with systems, equipment and layout designs. Comprehensive statement including some recent developments will be provided about: - Offsite and onsite sources requirements including sources dealing the total loss of off sites and main onsite sources. - Highlights of a relevant protection level against high frequencies disturbances emitted by lightning strokes, Interfaces data used by any supplier or designer such as site data, rooms temperature, equipment maximum design temperature, alternative current and direct current electrical network voltages and frequency variation ranges, environmental conditions decoupling data, - Environmental Qualification process including normal, mild (earthquake resistant), harsh and severe accident ambient conditions. A suit made approach based on families, which are defined as a combination of mission time, duration and abnormal conditions (pressure, temperature, radiation), enables to better cope with Environmental Qualifications

  12. Energy Code Enforcement Training Manual : Covering the Washington State Energy Code and the Ventilation and Indoor Air Quality Code.

    Energy Technology Data Exchange (ETDEWEB)

    Washington State Energy Code Program

    1992-05-01

    This manual is designed to provide building department personnel with specific inspection and plan review skills and information on provisions of the 1991 edition of the Washington State Energy Code (WSEC). It also provides information on provisions of the new stand-alone Ventilation and Indoor Air Quality (VIAQ) Code.The intent of the WSEC is to reduce the amount of energy used by requiring energy-efficient construction. Such conservation reduces energy requirements, and, as a result, reduces the use of finite resources, such as gas or oil. Lowering energy demand helps everyone by keeping electricity costs down. (It is less expensive to use existing electrical capacity efficiently than it is to develop new and additional capacity needed to heat or cool inefficient buildings.) The new VIAQ Code (effective July, 1991) is a natural companion to the energy code. Whether energy-efficient or not, an homes have potential indoor air quality problems. Studies have shown that indoor air is often more polluted than outdoor air. The VIAQ Code provides a means of exchanging stale air for fresh, without compromising energy savings, by setting standards for a controlled ventilation system. It also offers requirements meant to prevent indoor air pollution from building products or radon.

  13. Reducing Computational Overhead of Network Coding with Intrinsic Information Conveying

    DEFF Research Database (Denmark)

    Heide, Janus; Zhang, Qi; Pedersen, Morten V.

    is RLNC (Random Linear Network Coding) and the goal is to reduce the amount of coding operations both at the coding and decoding node, and at the same time remove the need for dedicated signaling messages. In a traditional RLNC system, coding operation takes up significant computational resources and adds...... the coding operations must be performed in a particular way, which we introduce. Finally we evaluate the suggested system and find that the amount of coding can be significantly reduced both at nodes that recode and decode.......This paper investigated the possibility of intrinsic information conveying in network coding systems. The information is embedded into the coding vector by constructing the vector based on a set of predefined rules. This information can subsequently be retrieved by any receiver. The starting point...

  14. Saving energy and reducing CO2 with electricity

    International Nuclear Information System (INIS)

    Yau, T.S.; Zaininger, H.W.

    1991-10-01

    Surprising potential exists for new and enhanced electric technologies to reduce energy use and CO 2 emission. Widespread deployment of these technologies could reduce energy use by up to 7 quads in 2010 and a corresponding reduction in carbon dioxide emission of up to 440 million tons. Electricity's unique high form value allows for efficiency at the point of end-use that is multiples of the efficiency possible in gas- or oil-fueled systems. The efficiency advantage at the point of end use more than offset the disadvantage of the high losses in the production of electricity. Hence, widespread deployment of many electric end uses will reduce the nation's total energy requirements. Major technologies which hold the greatest potential include electric process heating, industrial electrotechnologies, electric vehicles, information technologies that substitute electronic communication for transportation of people, and electric heat pumps for space heating, cooling and water heating. Wider use of these beneficial technologies in combination with the efficient use of electricity can reduce the nation's primary energy use and Co 2 emissions from electric generation by more than a quarter. 35 refs., 50 figs., 69 tabs

  15. Facial expression coding in children and adolescents with autism: Reduced adaptability but intact norm-based coding.

    Science.gov (United States)

    Rhodes, Gillian; Burton, Nichola; Jeffery, Linda; Read, Ainsley; Taylor, Libby; Ewing, Louise

    2018-05-01

    Individuals with autism spectrum disorder (ASD) can have difficulty recognizing emotional expressions. Here, we asked whether the underlying perceptual coding of expression is disrupted. Typical individuals code expression relative to a perceptual (average) norm that is continuously updated by experience. This adaptability of face-coding mechanisms has been linked to performance on various face tasks. We used an adaptation aftereffect paradigm to characterize expression coding in children and adolescents with autism. We asked whether face expression coding is less adaptable in autism and whether there is any fundamental disruption of norm-based coding. If expression coding is norm-based, then the face aftereffects should increase with adaptor expression strength (distance from the average expression). We observed this pattern in both autistic and typically developing participants, suggesting that norm-based coding is fundamentally intact in autism. Critically, however, expression aftereffects were reduced in the autism group, indicating that expression-coding mechanisms are less readily tuned by experience. Reduced adaptability has also been reported for coding of face identity and gaze direction. Thus, there appears to be a pervasive lack of adaptability in face-coding mechanisms in autism, which could contribute to face processing and broader social difficulties in the disorder. © 2017 The British Psychological Society.

  16. Environmental codes of practice for steam electric power generation

    International Nuclear Information System (INIS)

    1985-03-01

    The Design Phase Code is one of a series of documents being developed for the steam electric power generation industry. This industry includes fossil-fuelled stations (gas, oil and coal-fired boilers), and nuclear-powered stations (CANDU heavy water reactors). In this document, environmental concerns associated with water-related and solid waste activities of steam electric plants are discussed. Design recommendations are presented that will minimize the detrimental environmental effects of once-through cooling water systems, of wastewaters discharged to surface waters and groundwaters, and of solid waste disposal sites. Recommendations are also presented for the design of water-related monitoring systems and programs. Cost estimates associated with the implementation of these recommendations are included. These technical guides for new or modified steam electric stations are the result to consultation with a federal-provincial-industry task force

  17. Generalized rank weights of reducible codes, optimal cases and related properties

    DEFF Research Database (Denmark)

    Martinez Peñas, Umberto

    2018-01-01

    in network coding. In this paper, we study their security behavior against information leakage on networks when applied as coset coding schemes, giving the following main results: 1) we give lower and upper bounds on their generalized rank weights (GRWs), which measure worst case information leakage...... to the wire tapper; 2) we find new parameters for which these codes are MRD (meaning that their first GRW is optimal) and use the previous bounds to estimate their higher GRWs; 3) we show that all linear (over the extension field) codes, whose GRWs are all optimal for fixed packet and code sizes but varying...... length are reducible codes up to rank equivalence; and 4) we show that the information leaked to a wire tapper when using reducible codes is often much less than the worst case given by their (optimal in some cases) GRWs. We conclude with some secondary related properties: conditions to be rank...

  18. Photovoltaic Power Systems and the National Electrical Code: Suggested Practices

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-02-01

    This guide provides information on how the National Electrical Code (NEC) applies to photovoltaic systems. The guide is not intended to supplant or replace the NEC; it paraphrases the NEC where it pertains to photovoltaic systems and should be used with the full text of the NEC. Users of this guide should be thoroughly familiar with the NEC and know the engineering principles and hazards associated with electrical and photovoltaic power systems. The information in this guide is the best available at the time of publication and is believed to be technically accurate; it will be updated frequently.

  19. New electric technologies to reduce global warming impacts

    International Nuclear Information System (INIS)

    Courtright, H.A.

    1994-01-01

    Advanced electric technologies hold significant potential to reduce global warming impact through reduction of primary fuel needed to power end-use applications. These reductions can occur in two forms: (1) reduced kilowatt-hour usage and power plant emissions through efficiency improvements and technological enhancements of existing electrically-driven applications; (2) the development of new electric technologies to replace traditional fossil-fuel driven applications which can result in less overall primary energy consumption and lower overall emissions. Numerous new electric technologies are presently being developed by the Electric Power Research Institute. The technologies reviewed in this paper include: Microwave Fabric Dryer, Advanced Heat Pumps, Heat Pump Water Heater, Infrared Sand Reclaimer, Freeze Concentration, Membrane Water Recovery, Microwave Petrochemical Production, Infrared Drying, and Electric Vehicles. Full commercialization of these technologies can result in significant energy savings and CO 2 reductions, in addition to improving the competitiveness of businesses using these technologies

  20. Photovoltaic power systems and the National Electrical Code: Suggested practices

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.

    1996-12-01

    This guide provides information on how the National Electrical Code (NEC) applies to photovoltaic systems. The guide is not intended to supplant or replace the NEC; it paraphrases the NEC where it pertains to photovoltaic systems and should be used with the full text of the NEC. Users of this guide should be thoroughly familiar with the NEC and know the engineering principles and hazards associated with electrical and photovoltaic power systems. The information in this guide is the best available at the time of publication and is believed to be technically accurate; it will be updated frequently. Application of this information and results obtained are the responsibility of the user.

  1. Temporal code-driven stimulation: definition and application to electric fish signaling

    Directory of Open Access Journals (Sweden)

    Angel Lareo

    2016-10-01

    Full Text Available Closed-loop activity-dependent stimulation is a powerful methodology to assess information processing in biological systems. In this context, the development of novel protocols, their implementation in bioinformatics toolboxes and their application to different description levels open up a wide range of possibilities in the study of biological systems. We developed a methodology for studying biological signals representing them as temporal sequences of binary events. A specific sequence of these events (code is chosen to deliver a predefined stimulation in a closed-loop manner. The response to this code-driven stimulation can be used to characterize the system. This methodology was implemented in a real time toolbox and tested in the context of electric fish signaling. We show that while there are codes that evoke a response that cannot be distinguished from a control recording without stimulation, other codes evoke a characteristic distinct response. We also compare the code-driven response to open-loop stimulation. The discussed experiments validate the proposed methodology and the software toolbox.

  2. ADVANCED ELECTRIC AND MAGNETIC MATERIAL MODELS FOR FDTD ELECTROMAGNETIC CODES

    Energy Technology Data Exchange (ETDEWEB)

    Poole, B R; Nelson, S D; Langdon, S

    2005-05-05

    The modeling of dielectric and magnetic materials in the time domain is required for pulse power applications, pulsed induction accelerators, and advanced transmission lines. For example, most induction accelerator modules require the use of magnetic materials to provide adequate Volt-sec during the acceleration pulse. These models require hysteresis and saturation to simulate the saturation wavefront in a multipulse environment. In high voltage transmission line applications such as shock or soliton lines the dielectric is operating in a highly nonlinear regime, which require nonlinear models. Simple 1-D models are developed for fast parameterization of transmission line structures. In the case of nonlinear dielectrics, a simple analytic model describing the permittivity in terms of electric field is used in a 3-D finite difference time domain code (FDTD). In the case of magnetic materials, both rate independent and rate dependent Hodgdon magnetic material models have been implemented into 3-D FDTD codes and 1-D codes.

  3. ADVANCED ELECTRIC AND MAGNETIC MATERIAL MODELS FOR FDTD ELECTROMAGNETIC CODES

    International Nuclear Information System (INIS)

    Poole, B R; Nelson, S D; Langdon, S

    2005-01-01

    The modeling of dielectric and magnetic materials in the time domain is required for pulse power applications, pulsed induction accelerators, and advanced transmission lines. For example, most induction accelerator modules require the use of magnetic materials to provide adequate Volt-sec during the acceleration pulse. These models require hysteresis and saturation to simulate the saturation wavefront in a multipulse environment. In high voltage transmission line applications such as shock or soliton lines the dielectric is operating in a highly nonlinear regime, which require nonlinear models. Simple 1-D models are developed for fast parameterization of transmission line structures. In the case of nonlinear dielectrics, a simple analytic model describing the permittivity in terms of electric field is used in a 3-D finite difference time domain code (FDTD). In the case of magnetic materials, both rate independent and rate dependent Hodgdon magnetic material models have been implemented into 3-D FDTD codes and 1-D codes

  4. Building Energy Codes: Policy Overview and Good Practices

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Sadie [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-19

    Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

  5. A multi coding technique to reduce transition activity in VLSI circuits

    International Nuclear Information System (INIS)

    Vithyalakshmi, N.; Rajaram, M.

    2014-01-01

    Advances in VLSI technology have enabled the implementation of complex digital circuits in a single chip, reducing system size and power consumption. In deep submicron low power CMOS VLSI design, the main cause of energy dissipation is charging and discharging of internal node capacitances due to transition activity. Transition activity is one of the major factors that also affect the dynamic power dissipation. This paper proposes power reduction analyzed through algorithm and logic circuit levels. In algorithm level the key aspect of reducing power dissipation is by minimizing transition activity and is achieved by introducing a data coding technique. So a novel multi coding technique is introduced to improve the efficiency of transition activity up to 52.3% on the bus lines, which will automatically reduce the dynamic power dissipation. In addition, 1 bit full adders are introduced in the Hamming distance estimator block, which reduces the device count. This coding method is implemented using Verilog HDL. The overall performance is analyzed by using Modelsim and Xilinx Tools. In total 38.2% power saving capability is achieved compared to other existing methods. (semiconductor technology)

  6. Data and code for the exploratory data analysis of the electrical energy demand in the time domain in Greece.

    Science.gov (United States)

    Tyralis, Hristos; Karakatsanis, Georgios; Tzouka, Katerina; Mamassis, Nikos

    2017-08-01

    We present data and code for visualizing the electrical energy data and weather-, climate-related and socioeconomic variables in the time domain in Greece. The electrical energy data include hourly demand, weekly-ahead forecasted values of the demand provided by the Greek Independent Power Transmission Operator and pricing values in Greece. We also present the daily temperature in Athens and the Gross Domestic Product of Greece. The code combines the data to a single report, which includes all visualizations with combinations of all variables in multiple time scales. The data and code were used in Tyralis et al. (2017) [1].

  7. An Agent-Based Model for Zip-Code Level Diffusion of Electric Vehicles and Electricity Consumption in New York City

    Directory of Open Access Journals (Sweden)

    Azadeh Ahkamiraad

    2018-03-01

    Full Text Available Current power grids in many countries are not fully prepared for high electric vehicle (EV penetration, and there is evidence that the construction of additional grid capacity is constantly outpaced by EV diffusion. If this situation continues, then it will compromise grid reliability and cause problems such as system overload, voltage and frequency fluctuations, and power losses. This is especially true for densely populated areas where the grid capacity is already strained with existing old infrastructure. The objective of this research is to identify the zip-code level electricity consumption that is associated with large-scale EV adoption in New York City, one of the most densely populated areas in the United States (U.S.. We fuse the Fisher and Pry diffusion model and Rogers model within the agent-based simulation to forecast zip-code level EV diffusion and the required energy capacity to satisfy the charging demand. The research outcomes will assist policy makers and grid operators in making better planning decisions on the locations and timing of investments during the transition to smarter grids and greener transportation.

  8. Slag Evaluation to Reduce Energy Consumption and EAF Electrical Instability

    OpenAIRE

    Vieira,Deisi; Almeida,Rodolfo Arnaldo Montecinos de; Bielefeldt,Wagner Viana; Vilela,Antônio Cezar Faria

    2016-01-01

    In steel mills that operate with electric arc furnaces (EAF), it is interesting to ensure greater stability to the electric arc to aim at less distortion in the electrical system, with consequent reduction in electric power consumption. The slag foaming increases electric arc stability by reducing the total harmonic distortion (THD) between EAF phases. In this study, information about the chemical composition of the slag and electrical parameters of an EAF were collected. With the composition...

  9. Cost reducing code implementation strategies

    International Nuclear Information System (INIS)

    Kurtz, Randall L.; Griswold, Michael E.; Jones, Gary C.; Daley, Thomas J.

    1995-01-01

    Sargent and Lundy's Code consulting experience reveals a wide variety of approaches toward implementing the requirements of various nuclear Codes Standards. This paper will describe various Code implementation strategies which assure that Code requirements are fully met in a practical and cost-effective manner. Applications to be discussed includes the following: new construction; repair, replacement and modifications; assessments and life extensions. Lessons learned and illustrative examples will be included. Preferred strategies and specific recommendations will also be addressed. Sargent and Lundy appreciates the opportunity provided by the Korea Atomic Industrial Forum and Korean Nuclear Society to share our ideas and enhance global cooperation through the exchange of information and views on relevant topics

  10. Advanced Electric and Magnetic Material Models for FDTD Electromagnetic Codes

    CERN Document Server

    Poole, Brian R; Nelson, Scott D

    2005-01-01

    The modeling of dielectric and magnetic materials in the time domain is required for pulse power applications, pulsed induction accelerators, and advanced transmission lines. For example, most induction accelerator modules require the use of magnetic materials to provide adequate Volt-sec during the acceleration pulse. These models require hysteresis and saturation to simulate the saturation wavefront in a multipulse environment. In high voltage transmission line applications such as shock or soliton lines the dielectric is operating in a highly nonlinear regime, which requires nonlinear models. Simple 1-D models are developed for fast parameterization of transmission line structures. In the case of nonlinear dielectrics, a simple analytic model describing the permittivity in terms of electric field is used in a 3-D finite difference time domain code (FDTD). In the case of magnetic materials, both rate independent and rate dependent Hodgdon magnetic material models have been implemented into 3-D FDTD codes an...

  11. Coding conspecific identity and motion in the electric sense.

    Directory of Open Access Journals (Sweden)

    Na Yu

    Full Text Available Interactions among animals can result in complex sensory signals containing a variety of socially relevant information, including the number, identity, and relative motion of conspecifics. How the spatiotemporal properties of such evolving naturalistic signals are encoded is a key question in sensory neuroscience. Here, we present results from experiments and modeling that address this issue in the context of the electric sense, which combines the spatial aspects of vision and touch, with the temporal aspects of audition. Wave-type electric fish, such as the brown ghost knifefish, Apteronotus leptorhynchus, used in this study, are uniquely identified by the frequency of their electric organ discharge (EOD. Multiple beat frequencies arise from the superposition of the EODs of each fish. We record the natural electrical signals near the skin of a "receiving" fish that are produced by stationary and freely swimming conspecifics. Using spectral analysis, we find that the primary beats, and the secondary beats between them ("beats of beats", can be greatly influenced by fish swimming; the resulting motion produces low-frequency envelopes that broaden all the beat peaks and reshape the "noise floor". We assess the consequences of this motion on sensory coding using a model electroreceptor. We show that the primary and secondary beats are encoded in the afferent spike train, but that motion acts to degrade this encoding. We also simulate the response of a realistic population of receptors, and find that it can encode the motion envelope well, primarily due to the receptors with lower firing rates. We discuss the implications of our results for the identification of conspecifics through specific beat frequencies and its possible hindrance by active swimming.

  12. Reducing Carbon Dioxide Emissions from Electricity Sector Using Smart Electric Grid Applications

    Directory of Open Access Journals (Sweden)

    Lamiaa Abdallah

    2013-01-01

    Full Text Available Approximately 40% of global CO2 emissions are emitted from electricity generation through the combustion of fossil fuels to generate heat needed to power steam turbines. Burning these fuels results in the production of carbon dioxide (CO2—the primary heat-trapping, “greenhouse gas” responsible for global warming. Applying smart electric grid technologies can potentially reduce CO2 emissions. Electric grid comprises three major sectors: generation, transmission and distribution grid, and consumption. Smart generation includes the use of renewable energy sources (wind, solar, or hydropower. Smart transmission and distribution relies on optimizing the existing assets of overhead transmission lines, underground cables, transformers, and substations such that minimum generating capacities are required in the future. Smart consumption will depend on the use of more efficient equipment like energy-saving lighting lamps, enabling smart homes and hybrid plug-in electric vehicles technologies. A special interest is given to the Egyptian case study. Main opportunities for Egypt include generating electricity from wind and solar energy sources and its geographical location that makes it a perfect center for interconnecting electrical systems from the Nile basin, North Africa, Gulf, and Europe. Challenges include shortage of investments, absence of political will, aging of transmission and distribution infrastructure, and lack of consumer awareness for power utilization.

  13. A Novel Modified Algorithm with Reduced Complexity LDPC Code Decoder

    Directory of Open Access Journals (Sweden)

    Song Yang

    2014-10-01

    Full Text Available A novel efficient decoding algorithm reduced the sum-product algorithm (SPA Complexity with LPDC code is proposed. Base on the hyperbolic tangent rule, modified the Check node update with two horizontal process, which have similar calculation, Motivated by the finding that sun- min (MS algorithm reduce the complexity reducing the approximation error in the horizontal process, simplify the information weight small part. Compared with the exiting approximations, the proposed method is less computational complexity than SPA algorithm. Simulation results show that the author algorithm can achieve performance very close SPA.

  14. Applying Smart Grid Technology For Reducing Electric Energy Consumption

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Roy

    2010-09-15

    In recent years the term 'Smart Grid' has become a widely used buzz word with respect to the operation of Electric Power Systems. One analysis has suggested that a Smart Grid could potentially reduce annual energy consumption in the USA by 56 to 203 billion kWh in 2030, corresponding to a 1.2 to 4.3% reduction in projected retail electricity sales in 2030. This paper discusses some of the smart grid technologies pertaining to the operation of electric power distribution networks.

  15. Reduced dielectric response in spatially varying electric fields

    DEFF Research Database (Denmark)

    Hansen, Jesper Schmidt

    2015-01-01

    relations between the flux and the gradient of the polarization. Comparison between the theory and molecular dynamics simulations confirms this effect. The effect is significant for small length scale electric field variations and the inclusion of the flux is thus important in nanoscale modeling......In this paper, the dynamical equation for polarization is derived. From this the dielectric response to a spatially varying electric field is analyzed showing a reduced response due to flux of polarization in the material. This flux is modeled as a diffusive process through linear constitutive...

  16. MODELING CONTROLLED ASYNCHRONOUS ELECTRIC DRIVES WITH MATCHING REDUCERS AND TRANSFORMERS

    Directory of Open Access Journals (Sweden)

    V. S. Petrushin

    2015-04-01

    Full Text Available Purpose. Working out of mathematical models of the speed-controlled induction electric drives ensuring joint consideration of transformers, motors and loadings, and also matching reducers and transformers, both in static, and in dynamic regimes for the analysis of their operating characteristics. Methodology. At mathematical modelling are considered functional, mass, dimensional and cost indexes of reducers and transformers that allows observing engineering and economic aspects of speed-controlled induction electric drives. The mathematical models used for examination of the transitive electromagnetic and electromechanical processes, are grounded on systems of nonlinear differential equations with nonlinear coefficients (parameters of equivalent circuits of motors, varying in each operating point, including owing to appearances of saturation of magnetic system and current displacement in a winding of a rotor of an induction motor. For the purpose of raise of level of adequacy of models a magnetic circuit iron, additional and mechanical losses are considered. Results. Modelling of the several speed-controlled induction electric drives, different by components, but working on a loading equal on character, magnitude and a demanded control range is executed. At use of characteristic families including mechanical, at various parameters of regulating on which performances of the load mechanism are superimposed, the adjusting characteristics representing dependences of a modification of electrical, energy and thermal magnitudes from an angular speed of motors are gained. Originality. The offered complex models of speed-controlled induction electric drives with matching reducers and transformers, give the chance to realize well-founded sampling of components of drives. They also can be used as the design models by working out of speed-controlled induction motors. Practical value. Operating characteristics of various speed-controlled induction electric

  17. Assessing and Reducing Miscellaneous Electric Loads (MELs) in Lodging

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Emily M.

    2011-09-01

    Miscellaneous electric loads (MELs) are the loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. This report reviews methods to reduce MELs in lodging.

  18. An electrical method for the measurement of the thermal and electrical conductivity of reduced graphene oxide nanostructures.

    Science.gov (United States)

    Schwamb, Timo; Burg, Brian R; Schirmer, Niklas C; Poulikakos, Dimos

    2009-10-07

    This paper introduces an electrical four-point measurement method enabling thermal and electrical conductivity measurements of nanoscale materials. The method was applied to determine the thermal and electrical conductivity of reduced graphene oxide flakes. The dielectrophoretically deposited samples exhibited thermal conductivities in the range of 0.14-2.87 W m(-1) K(-1) and electrical conductivities in the range of 6.2 x 10(2)-6.2 x 10(3) Omega(-1) m(-1). The measured properties of each flake were found to be dependent on the duration of the thermal reduction and are in this sense controllable.

  19. Electromagnetic simulations of the ASDEX Upgrade ICRF Antenna with the TOPICA code

    International Nuclear Information System (INIS)

    Krivska, A.; Milanesio, D.; Bobkov, V.; Braun, F.; Noterdaeme, J.-M.

    2009-01-01

    Accurate and efficient simulation tools are necessary to optimize the ICRF antenna design for a set of operational conditions. The TOPICA code was developed for performance prediction and for the analysis of ICRF antenna systems in the presence of plasma, given realistic antenna geometries. Fully 3D antenna geometries can be adopted in TOPICA, just as in available commercial codes. But while those commercial codes cannot operate with a plasma loading, the TOPICA code correctly accounts for realistic plasma loading conditions, by means of the coupling with 1D FELICE code. This paper presents the evaluation of the electric current distribution on the structure, of the parallel electric field in the region between the straps and the plasma and the computation of sheaths driving RF potentials. Results of TOPICA simulations will help to optimize and re-design the ICRF ASDEX Upgrade antenna in order to reduce tungsten (W) sputtering attributed to the rectified sheath effect during ICRF operation.

  20. Data supporting the assessment of biomass based electricity and reduced GHG emissions in Cuba.

    Science.gov (United States)

    Sagastume Gutiérrez, Alexis; Cabello Eras, Juan J; Vandecasteele, Carlo; Hens, Luc

    2018-04-01

    Assessing the biomass based electricity potential of developing nations like Cuba can help to reduce the fossil fuels dependency and the greenhouse gas emissions. The data included in this study present the evolution of electricity production and greenhouse gas emissions in Cuba. Additionally, the potentialities to produce biomass based electricity by using the most significant biomass sources in Cuba are estimated. Furthermore, estimations of the potential reductions of greenhouse gas emissions, resulting from implementing the biomass based electricity potential of the different sources discussed in the study, are included. Results point to the most promising biomass sources for electricity generation and their potential to reduce GHG emissions.

  1. Potential for reducing global carbon emissions from electricity production-A benchmarking analysis

    International Nuclear Information System (INIS)

    Ang, B.W.; Zhou, P.; Tay, L.P.

    2011-01-01

    We present five performance indicators for electricity generation for 129 countries using the 2005 data. These indicators, measured at the national level, are the aggregate CO 2 intensity of electricity production, the efficiencies of coal, oil and gas generation and the share of electricity produced from non-fossil fuels. We conduct a study on the potential for reducing global energy-related CO 2 emissions from electricity production through simple benchmarking. This is performed based on the last four performance indicators and the construction of a cumulative curve for each of these indicators. It is found that global CO 2 emissions from electricity production would be reduced by 19% if all these indicators are benchmarked at the 50th percentile. Not surprisingly, the emission reduction potential measured in absolute terms is the highest for large countries such as China, India, Russia and the United States. When the potential is expressed as a percentage of a country's own emissions, few of these countries appear in the top-five list. - Research highlights: → We study variations in emissions per kWh of electricity generated among countries. → We analyze emissions from electricity production through benchmarking. → Estimates of reduction in emissions are made based on different assumptions.

  2. The development of the Nuclear Electric core performance and fault transient analysis code package in support of Sizewell B

    International Nuclear Information System (INIS)

    Hall, P.; Hutt, P.

    1994-01-01

    This paper describes Nuclear Electric's (NE) development of an integrated code package in support of all its reactors including Sizewell B, designed for the provision of fuel management design, core performance studies, operational support and fault transient analysis. The package uses the NE general purpose three-dimensional transient reactor physics code PANTHER with cross-sections derived in the PWR case from the LWRWIMS LWR lattice neutronics code. The package also includes ENIGMA a generic fuel performance code and for PWR application VIPRE-01 a subchannel thermal hydraulics code, RELAP5 the system thermal hydraulics transient code and SCORPIO an on-line surveillance system. The paper describes the capabilities and validation of the elements of this package for PWR, how they are coupled within the package and the way in which they are being applied for Sizewell B to on-line surveillance and fault transient analysis. (Author)

  3. Electrical current mediated interconversion between graphene oxide to reduced grapene oxide

    Science.gov (United States)

    Teoh, H. F.; Tao, Y.; Tok, E. S.; Ho, G. W.; Sow, C. H.

    2011-04-01

    In this work, we demonstrate that graphene oxide (GO) can be reversibly converted to reduced-graphene-oxide (rGO) through the use of electric current. Strong electric field could cause ionization of water molecules in air to generate H+ ions at cathode, causing GO to be reduced. When the bias is reversed, the same electrode becomes positive and OH- ions are produced. According to Le Chatelier Principle, it then favors the reverse reaction, converting rGO back to GO, GO+2H++2e-=>rGO+H2O. X-ray spectroscopy and Raman spectroscopy were carried to verify the conversion reversibility in the reversed process.

  4. Manchester Coding Option for SpaceWire: Providing Choices for System Level Design

    Science.gov (United States)

    Rakow, Glenn; Kisin, Alex

    2014-01-01

    This paper proposes an optional coding scheme for SpaceWire in lieu of the current Data Strobe scheme for three reasons. First reason is to provide a straightforward method for electrical isolation of the interface; secondly to provide ability to reduce the mass and bend radius of the SpaceWire cable; and thirdly to provide a means for a common physical layer over which multiple spacecraft onboard data link protocols could operate for a wide range of data rates. The intent is to accomplish these goals without significant change to existing SpaceWire design investments. The ability to optionally use Manchester coding in place of the current Data Strobe coding provides the ability to DC balanced the signal transitions unlike the SpaceWire Data Strobe coding; and therefore the ability to isolate the electrical interface without concern. Additionally, because the Manchester code has the clock and data encoded on the same signal, the number of wires of the existing SpaceWire cable could be optionally reduced by 50. This reduction could be an important consideration for many users of SpaceWire as indicated by the already existing effort underway by the SpaceWire working group to reduce the cable mass and bend radius by elimination of shields. However, reducing the signal count by half would provide even greater gains. It is proposed to restrict the data rate for the optional Manchester coding to a fixed data rate of 10 Megabits per second (Mbps) in order to make the necessary changes simple and still able to run in current radiation tolerant Field Programmable Gate Arrays (FPGAs). Even with this constraint, 10 Mbps will meet many applications where SpaceWire is used. These include command and control applications and many instruments applications with have moderate data rate. For most NASA flight implementations, SpaceWire designs are in rad-tolerant FPGAs, and the desire to preserve the heritage design investment is important for cost and risk considerations. The

  5. An electric mandate. The EU procedure for harmonising cross-border network codes for electricity

    Energy Technology Data Exchange (ETDEWEB)

    Jevnaker, Torbjoerg

    2012-07-01

    The research question addressed in this report is why the EU procedure for developing network codes for electricity was enacted in its particular form. Passed by the EU in 2009, European organisations partly outside of the formal EU structure were given a mandate to make rules that would apply across the EU. This was puzzling given the observed resistance on part of the member states to let go of national control over energy issues. Drawing on institutionalist perspectives, the analysis shows that the procedure would not have been passed without support from and compromise among the Commission, European Parliament and the member states in Council; that parts of the procedure imitated existing practices within related policy areas; that horizontal and vertical specialization within the nation-states along with a Commission actively promoting transnational cooperation changed the feedback mechanisms, which changed the direction of European energy market regulation; and finally, that the new actors played an active role vis-a-vis EU bodies as the latter were legislating on the procedure. (Author)

  6. Aspects of the design of the automated system for code generation of electrical items of technological equipment

    Directory of Open Access Journals (Sweden)

    Erokhin V.V.

    2017-09-01

    Full Text Available The article presents the aspects of designing an automated system for generating codes for electrical elements of process equipment using CASE-means. We propose our own technology of iterative development of such systems. The proposed methodology uses the tool to develop the ERwin Data Modeler databases of Computer Associates and the author's tool for the automatic generation of ERwin Class Builder code. The implemented design tool is a superstructure over the ERwin Data Modeler from Computer Associates, which extends its functionality. ERwin Data Modeler works with logical and physical data models and allows you to generate a description of the database and ddl-scripts.

  7. Tribal Green Building Administrative Code Example

    Science.gov (United States)

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  8. Using Geothermal Electric Power to Reduce Carbon Footprint

    Science.gov (United States)

    Crombie, George W.

    Human activities, including the burning of fossil fuels, increase carbon dioxide levels, which contributes to global warming. The research problem of the current study examined if geothermal electric power could adequately replace fossil fuel by 2050, thus reducing the emissions of carbon dioxide while avoiding potential problems with expanding nuclear generation. The purpose of this experimental research was to explore under what funding and business conditions geothermal power could be exploited to replace fossil fuels, chiefly coal. Complex systems theory, along with network theory, provided the theoretical foundation for the study. Research hypotheses focused on parameters, such as funding level, exploration type, and interfaces with the existing power grid that will bring the United States closest to the goal of phasing out fossil based power by 2050. The research was conducted by means of computer simulations, using agent-based modeling, wherein data were generated and analyzed. The simulations incorporated key information about the location of geothermal resources, exploitation methods, transmission grid limits and enhancements, and demand centers and growth. The simulation suggested that rapid and aggressive deployment of geothermal power plants in high potential areas, combined with a phase out of coal and nuclear plants, would produce minimal disruptions in the supply of electrical power in the United States. The implications for social change include reduced risk of global warming for all humans on the planet, reduced pollution due to reduction or elimination of coal and nuclear power, increased stability in energy supply and prices in the United States, and increased employment of United States citizens in jobs related to domestic energy production.

  9. Potential for reducing global carbon emissions from electricity production-A bench marking analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ang, B.W.; Zhou, P.; Tay, L.P. [National University of Singapore (Singapore). Department of Industrial and Systems Engineering

    2011-05-15

    We present five performance indicators for electricity generation for 129 countries using the 2005 data. These indicators, measured at the national level, are the aggregate CO{sub 2} intensity of electricity production, the efficiencies of coal, oil and gas generation and the share of electricity produced from non-fossil fuels. We conduct a study on the potential for reducing global energy-related CO{sub 2} emissions from electricity production through simple bench marking. This is performed based on the last four performance indicators and the construction of a cumulative curve for each of these indicators. It is found that global CO{sub 2} emissions from electricity production would be reduced by 19% if all these indicators are benchmarked at the 50th percentile. Not surprisingly, the emission reduction potential measured in absolute terms is the highest for large countries such as China, India, Russia and the United States. When the potential is expressed as a percentage of a country's own emissions, few of these countries appear in the top-five list. 14 refs., 8 figs., 4 tabs.

  10. Tokamak Systems Code

    International Nuclear Information System (INIS)

    Reid, R.L.; Barrett, R.J.; Brown, T.G.

    1985-03-01

    The FEDC Tokamak Systems Code calculates tokamak performance, cost, and configuration as a function of plasma engineering parameters. This version of the code models experimental tokamaks. It does not currently consider tokamak configurations that generate electrical power or incorporate breeding blankets. The code has a modular (or subroutine) structure to allow independent modeling for each major tokamak component or system. A primary benefit of modularization is that a component module may be updated without disturbing the remainder of the systems code as long as the imput to or output from the module remains unchanged

  11. Reducing CO2 emissions on the electric grid through a carbon disincentive policy

    International Nuclear Information System (INIS)

    Li, Chiao-Ting; Peng, Huei; Sun, Jing

    2013-01-01

    This paper studies the operation of an electric grid with renewable wind generation and plug-in electric vehicles (PEVs). In particular, PEVs will be the controllable demand that can mitigate the intermittency in wind generation and improve the capacity factors of the non-renewable generation assets on the grid. Optimization problems are formulated to minimize the costs of electricity generation, and two approaches are proposed to address the grid CO 2 emission in the optimization. The first approach directly penalizes CO 2 in the objective function, and the second approach adopts a carbon disincentive policy to alter the dispatch order of power plants, so that expensive low-CO 2 plants can replace cheap high-CO 2 plants. These two approaches result in very different outcomes: the first approach affects only the PEV charging demand on the grid and does not result in significant CO 2 reduction, whereas the second approach controls both the generation and load, and CO 2 can be reduced substantially. In addition, the carbon disincentive policy, unlike a carbon tax, does not collect any revenue; therefore, the increase in electricity cost is minimal. The effect of the proposed algorithms on the grid electricity cost and carbon emission is analyzed in details and reported. - Highlights: • We study the tradeoff between CO 2 emissions and generation cost on an electric grid. • The tradeoff was shown by Pareto fronts obtained from optimizations. • Pareto fronts shows that a carbon disincentive is effective in reducing emissions. • Controlling both supply and demand on the grid is necessary to reduce CO 2 and costs

  12. Controlling Electrical Hazards

    National Research Council Canada - National Science Library

    1997-01-01

    ...). In general, OSHA's electrical standards are based on the National Fire Protection Associations Standard NFPA 70E, Electrical Safety Requirements for Employee Workplaces, and in turn, from the National Electrical Code (NEC...

  13. One watt initiative: A global effort to reduce leaking electricity

    International Nuclear Information System (INIS)

    Meier, Alan K.; LeBot, Benoit

    1999-01-01

    Many domestic appliances and commercial equipment consume some electric power when they are switched off or not performing their primary purpose. The typical loss per appliance is low (from 1 to 25 W) but, when multiplied by the billions of appliances in houses and in commercial buildings, standby losses represent a significant fraction of total electricity use. Several initiatives to reduce standby losses have appeared in different parts of the world. One proposal, the 1-watt plan, seeks to harmonize these initiatives by establishing a single target for all appliances. This paper explains the background to the 1-watt plan, identifies some unresolved aspects, and gives some estimates of energy savings

  14. Efficient Use of Behavioral Tools to Reduce Electricity Demand of Domestic Consumers

    Directory of Open Access Journals (Sweden)

    Elbaz Shimon

    2016-12-01

    Full Text Available Purpose: The present study investigated the main literature on the subject of methods and policies for reducing the electricity demand of domestic consumers, in order to identify the place of behavioral tools. Methodology: We used secondary sources, performing a literature review, together with analysis and synthesis. Findings: Policy makers prefer to use tools offered by neoclassical economics, such as various forms of taxation, fines and financial incentives in order to make domestic electricity consumers save electricity, on the assumption that consumers will make rational decisions while maximizing their personal benefit. However, studies conducted in recent years in the field of behavioral economics, which are based on the assumption that consumers’ decisions are not rational and are affected by cognitive biases, showed that the use of behavioral tools, such as detailed online information (feedback,social comparison information, information on varying rates (dynamic pricing and general information (advertising campaign, are tools that are not less appropriate than the ones the neoclassical economics offers, mainly because electricity is an invisible product and consumers are unable to assess it by normal cognitive measures. Using an interdisciplinary combination of behavioral tools that come from a variety of approaches taken from a wide variety of different academic fields, it is possible to receive efficient results in the endeavor of reducing electricity demand. Implications: Although the neoclassical economics still remains the fundamental theory used by policymakers, it is recommended to consider behavioral economics as a complementary approach to the neoclassical economics, and combine behavioral tools in the policymakers’ toolbox, especially when those tools do not require a significant financial investment, thus efficiently maximizing the reduction of electricity demand among domestic consumers. These theoretical results will be

  15. Reducing consumption of electric current and energy carriers. [USSR

    Energy Technology Data Exchange (ETDEWEB)

    Ruppo, A.S.; Gruzdev, Yu.M.

    1985-01-01

    Evaluates the energy conservation program developed by the Giproshakht research institute is evaluated. The program was used in the Afanas'evo hydraulic mine in the Tulaugol association (with annual coal output of 2.1 Mt). Energy conservation program consisted of 2 groups of tasks: reducing energy consumption of the mine, and reducing energy consumption during the maximum demand hours in the morning and evening. The following methods were used: reducing idle running of chain and belt conveyors, separate draining of mine water free of dust and rock particles (reducing range of water cleaning), use of automatic control systems for mine blowers, automatic control of the system for coal drying, more efficient use of coal and materials transport in the mine. Energy demand of the mine during peak demand hours was reduced by adjusting fluctuations of energy consumption of the mine to fluctuations of energy demand in the power system of the area, e.g. by reducing mine draining in the morning and evening and operating at full capacity during the time of reduced energy demand. Using the energy conservation measures economized 4,324,300 kWh electric energy annually.

  16. Computer codes for designing proton linear accelerators

    International Nuclear Information System (INIS)

    Kato, Takao

    1992-01-01

    Computer codes for designing proton linear accelerators are discussed from the viewpoint of not only designing but also construction and operation of the linac. The codes are divided into three categories according to their purposes: 1) design code, 2) generation and simulation code, and 3) electric and magnetic fields calculation code. The role of each category is discussed on the basis of experience at KEK (the design of the 40-MeV proton linac and its construction and operation, and the design of the 1-GeV proton linac). We introduce our recent work relevant to three-dimensional calculation and supercomputer calculation: 1) tuning of MAFIA (three-dimensional electric and magnetic fields calculation code) for supercomputer, 2) examples of three-dimensional calculation of accelerating structures by MAFIA, 3) development of a beam transport code including space charge effects. (author)

  17. Reducing operating costs: A collaborative approach between industry and electric utilities

    International Nuclear Information System (INIS)

    Tyers, B.; Sibbald, L.

    1993-01-01

    The unit cost of electricity to industrial consumers is expected to increase at a rate of 5% annually in the 1990s. The partnership that has been created between Amoco Canada Petroleum Company and TransAlta Utilities to control the cost of electricity is described. To allow the company to receive lower rates for interruptible power, a number of measures have been taken. The Amoco Whitecourt plant has standby generators in reserve that can be used when utility power is not available. A Pembina compressor can be turned off for up to 12 hours, at 30 minutes notice, without affecting field pressure. At the East Crossfield plant sales gas can be compressed using electricity or a gas-driven engine. Spot market energy is used in a number of plants allowing electric drive alternatives to plant operators and offering short term energy markets. TransAlta invests in electrical equipment such as switchgear as well as transmission lines and transformers. New rate alternatives offered by TransAlta Utilities include review of the need for a demand ratchet, additional time of use rates, unbundling of rates allowing power purchase from alternative sources, rates that follow product costs, reduced rates for conversion of gas to electric drives certain circumstances, energy audits, and power factor credits. 5 figs

  18. Electrical characterization of reduced graphene oxide (rGO) on organic thin film transistor (OTFT)

    Science.gov (United States)

    Musa, Nurhazwani; Halim, Nurul Farhanah Ab.; Ahmad, Mohd Noor; Zakaria, Zulkhairi; Hashim, Uda

    2017-03-01

    A green method and eco-friendly solution were used to chemically reduce graphene oxide (GO) to graphene using green reductant. In this study, graphene oxide (GO) were prepared by using Tours method. Then, reduced graphene oxides (rGO) were prepared by using three typical reduction agents: L-ascorbic acid (L-AA), formamidinesulfinic acid (FAS) and sodium sulfite (Na2SO3). The reduced materials were characterized by Fourier transform infrared spectroscopy (FTIR), Thermo gravimetric analysis (TGA) and X-ray diffraction (XRD). Graphene based organic thin film transistor (G-OTFT) was prepared by a spin coating and thermal evaporation technique. The electrical characterization of G-OTFT was analyzed by using semiconductor parameter analyzer (SPA). The G-OTFT devices show p-type semiconducting behaviour. This article focuses on the synthesis and reduction of graphene oxide using three different reductants in order to maximise its electrical conductivity. The rGO product demonstrated a good electrical conductivity performance with highly sensitivity sensor.

  19. Ab initio theories of electric transport in solid systems with reduced dimensions

    International Nuclear Information System (INIS)

    Weinberger, Peter

    2003-01-01

    Ab initio theories of electric transport in solid systems with reduced dimensions, i.e., systems that at best are characterized by two-dimensional translational invariance, are reviewed in terms of a fully relativistic description of the Kubo-Greenwood equation. As the use of this equation requires concepts such as collinearity and non-collinearity in order to properly define resistivities or resistances corresponding to particular magnetic configurations, respective consequences of the (local) density functional theory are recalled in quite a detailed manner. Furthermore, since theoretical descriptions of solid systems with reduced dimensions require quantum mechanical methods different from bulk systems (three-dimensional periodicity), the so-called Screened Korringa-Kohn-Rostoker (SKKR-) method for layered systems is introduced together with a matching coherent potential approximation (inhomogeneous CPA). The applications shown are mainly meant to illustrate various aspects of electric transport in solid systems with reduced dimensions and comprise not only current-in-plane (CIP) experiments, but also current perpendicular to the planes of atoms geometries, consequences of tunneling, and finite nanostructures at or on metallic substrates. In order to give a more complete view of available ab initio methods also a non-relativistic approach based on the Tight Binding Linear Combination of muffin tin orbitals (TB-LMTO-) method and the so-called Kubo-Landauer equation in terms of transmission and reflection matrices is presented. A compilation of references with respect to ab-initio type approaches not explicitly discussed in here finally concludes the discussion of electric properties in solid systems with reduced dimensions

  20. Using Economic Incentives to Reduce Electricity Consumption: A field Experiment in Matsuyama, Japan

    Directory of Open Access Journals (Sweden)

    Kenichi Mizobuchi

    2012-01-01

    Full Text Available This study examines the effectiveness of economic incentives in promoting electricity-conservation behavior among Japanese households. Fifty-three Japanese households participated in a field experiment and were offered monetary rewards depending on their rate of reduction in electricity consumption. To avoid bias in sample selection, which is typically present in previous studies, we adopted a request-based approach for recruiting participants. Results showed that only 34% of the participants succeeded in reducing their electricity consumption, and the average reduction rate was –4.8%. Econometric analysis confirmed that monetary rewards had a positive influence on the electricity conservation behavior, especially of family members who typically stay at home on weekdays. Responses to the questionnaires administered before and after the experiment suggest that participants may have underestimated the marginal costs of the electricity conservation behavior. The efficacy of economic incentives, established in our study, offers a potential measure for encouraging electricity-conservation behavior among Japanese households.

  1. Alternative Fuels Data Center: Codes and Standards Resources

    Science.gov (United States)

    resources linked below help project developers and code officials prepare and review code-compliant projects , storage, and infrastructure. The following charts show the SDOs responsible for these alternative fuel codes and standards. Biodiesel Vehicle and Infrastructure Codes and Standards Chart Electric Vehicle and

  2. Low Complexity List Decoding for Polar Codes with Multiple CRC Codes

    Directory of Open Access Journals (Sweden)

    Jong-Hwan Kim

    2017-04-01

    Full Text Available Polar codes are the first family of error correcting codes that provably achieve the capacity of symmetric binary-input discrete memoryless channels with low complexity. Since the development of polar codes, there have been many studies to improve their finite-length performance. As a result, polar codes are now adopted as a channel code for the control channel of 5G new radio of the 3rd generation partnership project. However, the decoder implementation is one of the big practical problems and low complexity decoding has been studied. This paper addresses a low complexity successive cancellation list decoding for polar codes utilizing multiple cyclic redundancy check (CRC codes. While some research uses multiple CRC codes to reduce memory and time complexity, we consider the operational complexity of decoding, and reduce it by optimizing CRC positions in combination with a modified decoding operation. Resultingly, the proposed scheme obtains not only complexity reduction from early stopping of decoding, but also additional reduction from the reduced number of decoding paths.

  3. LDGM Codes for Channel Coding and Joint Source-Channel Coding of Correlated Sources

    Directory of Open Access Journals (Sweden)

    Javier Garcia-Frias

    2005-05-01

    Full Text Available We propose a coding scheme based on the use of systematic linear codes with low-density generator matrix (LDGM codes for channel coding and joint source-channel coding of multiterminal correlated binary sources. In both cases, the structures of the LDGM encoder and decoder are shown, and a concatenated scheme aimed at reducing the error floor is proposed. Several decoding possibilities are investigated, compared, and evaluated. For different types of noisy channels and correlation models, the resulting performance is very close to the theoretical limits.

  4. The impact of changing computing technology on EPRI [Electric Power Research Institute] nuclear analysis codes

    International Nuclear Information System (INIS)

    Breen, R.J.

    1988-01-01

    The Nuclear Reload Management Program of the Nuclear Power Division (NPD) of the Electric Power Research Institute (EPRI) has the responsibility for initiating and managing applied research in selected nuclear engineering analysis functions for nuclear utilities. The computer systems that result from the research projects consist of large FORTRAN programs containing elaborate computational algorithms used to access such areas as core physics, fuel performance, thermal hydraulics, and transient analysis. This paper summarizes a study of computing technology trends sponsored by the NPD. The approach taken was to interview hardware and software vendors, industry observers, and utility personnel focusing on expected changes that will occur in the computing industry over the next 3 to 5 yr. Particular emphasis was placed on how these changes will impact engineering/scientific computer code development, maintenance, and use. In addition to the interviews, a workshop was held with attendees from EPRI, Power Computing Company, industry, and utilities. The workshop provided a forum for discussing issues and providing input into EPRI's long-term computer code planning process

  5. Air quality enhancement by reducing emissions from electric power industry

    International Nuclear Information System (INIS)

    Hamzeh, Ali

    2006-01-01

    The electric power industry is responsible for electricity generations, transmission and distribution. The system is dominated by thermal electricity generation (in Syria its share is about 80%). The fossil fuels used in te thermal power plants are a major stationary source of greenhouse gases (GHG) in addition to other pollutant. The primary GHG are CO 2 , NO x , SO 2 , CO, and VOC, of which CO 2 is believed to account for about half of the global warming. There are many approaches to reduce the amount of pollutants emitted from power systems. The best measures as given mainly by Intergovernmental Panel on Climate Change (IPCC), 1996 are presented in the paper. From the efficiency and sustainability side of view, the implementation of these approaches cannot be done optimally without an integrated environmental management program (EMP). The paper proposes an EMP as a conceptual strategy using a set of evaluation criteria to be applied on the power system on concern. As a final item, a case study of the Syrian power system is presented. The energy system in Syria emitted about 115 million tons of CO 2 in the year 2000. The electric power system alone consumes approximately 36% of the total consumed fossil fuels in the country, and is responsible of about 35-40% of the CO 2 emissions. The Syrian power system has three major problems (like many systems in the region) which need to be resolved in order to improve its operation and consequently to reduce the emission of green house gases. First, the technical electrical losses are about 25-30% of net generated electricity. Second, the power factor has reached alarming levels in various parts of the power system. Third, the efficiencies in all power plant units are very low and still decreasing rapidly. The paper gives an overview of the energy sector in Syria showing a significant potential for energy efficiency and environmental protection projects. The main outcome of the case study is a comprehensive program

  6. A New Contribution in Reducing Electric Field Distribution Within/Around Medium Voltage Underground Cable Terminations

    Directory of Open Access Journals (Sweden)

    S. S. Desouky

    2017-10-01

    Full Text Available Ιn medium voltage cables, the stress control layers play an important part in controlling the electric field distribution around the medium voltage underground cable terminations. Underground cable accessories, used in medium voltage cable systems, need a stress control tube in order to maintain and control the insulation level which is designed for long life times. The term “electrical stress control” refers to the cable termination analysis of optimizing the electrical stress in the area of insulation shield cutback to reduce the electrical field concentration at this point in order to reduce breakdown in the cable insulation. This paper presents the effect of some materials of different relative permittivities and geometrical regulation with the curved shape stress relief cones on the electric field distribution of cable termination. The optimization was done by comparing the results of eight materials used. Also, the effect of the change in the thickness of the stress control tube is presented. The modeling design is very important for engineers to find the optimal solution of terminator design of medium voltage cables. This paper also describes the evolution of stress control systems and their benefits. A developed program using Finite Element Method (FEM has calculated a numerical study to the stress control layering electric field distribution.

  7. Reducing Electrical Consumption in the Forest Products Industry Using Lean Thinking

    Directory of Open Access Journals (Sweden)

    Scott William Lyon

    2014-01-01

    Full Text Available The forest products industry has an opportunity to reduce energy costs using energy management practices, thereby boosting its global competitiveness. Increasing manufacturing costs have contributed significantly to the decline of the forest products manufacturing industries in the U.S.; these increasing costs limit manufacturers’ abilities to compete with their global competitors. U.S. companies are continually improving their products, processes, finances, and business practices to better compete with global marketplaces; however, they may not be seizing all of the opportunities available through more efficient energy consumption practices. By eliminating non-valued added activities, lean thinking is an example of one tool that may improve performance and reduce costs. A case study was conducted at a cabinet manufacturer in Virginia to examine the impact of lean thinking on the consumption of electricity in the manufacturing process. An energy management system was used to provide rapid feedback on electrical energy consumption for production operations. Significant changes were observed after implementing energy reduction practices identified by lean thinking tools.

  8. Autistic traits are linked to reduced adaptive coding of face identity and selectively poorer face recognition in men but not women.

    Science.gov (United States)

    Rhodes, Gillian; Jeffery, Linda; Taylor, Libby; Ewing, Louise

    2013-11-01

    Our ability to discriminate and recognize thousands of faces despite their similarity as visual patterns relies on adaptive, norm-based, coding mechanisms that are continuously updated by experience. Reduced adaptive coding of face identity has been proposed as a neurocognitive endophenotype for autism, because it is found in autism and in relatives of individuals with autism. Autistic traits can also extend continuously into the general population, raising the possibility that reduced adaptive coding of face identity may be more generally associated with autistic traits. In the present study, we investigated whether adaptive coding of face identity decreases as autistic traits increase in an undergraduate population. Adaptive coding was measured using face identity aftereffects, and autistic traits were measured using the Autism-Spectrum Quotient (AQ) and its subscales. We also measured face and car recognition ability to determine whether autistic traits are selectively related to face recognition difficulties. We found that men who scored higher on levels of autistic traits related to social interaction had reduced adaptive coding of face identity. This result is consistent with the idea that atypical adaptive face-coding mechanisms are an endophenotype for autism. Autistic traits were also linked with face-selective recognition difficulties in men. However, there were some unexpected sex differences. In women, autistic traits were linked positively, rather than negatively, with adaptive coding of identity, and were unrelated to face-selective recognition difficulties. These sex differences indicate that autistic traits can have different neurocognitive correlates in men and women and raise the intriguing possibility that endophenotypes of autism can differ in males and females. © 2013 Elsevier Ltd. All rights reserved.

  9. Finite element based electric motor design optimization

    Science.gov (United States)

    Campbell, C. Warren

    1993-01-01

    The purpose of this effort was to develop a finite element code for the analysis and design of permanent magnet electric motors. These motors would drive electromechanical actuators in advanced rocket engines. The actuators would control fuel valves and thrust vector control systems. Refurbishing the hydraulic systems of the Space Shuttle after each flight is costly and time consuming. Electromechanical actuators could replace hydraulics, improve system reliability, and reduce down time.

  10. The status of Korean nuclear codes and standards

    International Nuclear Information System (INIS)

    Namha Kim; Jong-Hae Kim

    2005-01-01

    Korea Electric Power Industry Code (KEPIC), a set of integrated standards applicable to the design, construction and operation of electric power facilities including nuclear power plants, has been developed on the basis of referring to the prevailing U.S. codes and standards which had been applied to the electric power facilities in Korea. Being the developing and managing organization of KEPIC, Korea Electric Association (KEA) published its first edition in 1995, the second in 200,0 and is expected to publish the 2005 edition. KEPIC was applied to the construction of Ulchin Nuclear Units 5 and 6 in 1997, and will be applicable to the construction of forthcoming nuclear power plants in Korea. Along with the effectuation of the Agreement on Technical Barriers to Trade (TBT) in 1995, the international trend related to codes and standards is changing rapidly. The KEA is, therefore, making its utmost efforts so as for KEPIC to keep abreast with the changing environment in international arena. KEA notified ISO/IEC Information Centre of its acceptance of the Code of Good Practice in the Agreement on TBT. The 2005 KEPIC edition will be retrofitted according to the ISO/IEC Guide 21- Adoption of International Standards as regional or national standards. KEA's efforts will help KEPIC correspond with international standards such as ISO/IEC standards, and internationally recognized standards such as ASME codes and standards. (authors)

  11. Bursts generate a non-reducible spike-pattern code

    Directory of Open Access Journals (Sweden)

    Hugo G Eyherabide

    2009-05-01

    Full Text Available On the single-neuron level, precisely timed spikes can either constitute firing-rate codes or spike-pattern codes that utilize the relative timing between consecutive spikes. There has been little experimental support for the hypothesis that such temporal patterns contribute substantially to information transmission. Using grasshopper auditory receptors as a model system, we show that correlations between spikes can be used to represent behaviorally relevant stimuli. The correlations reflect the inner structure of the spike train: a succession of burst-like patterns. We demonstrate that bursts with different spike counts encode different stimulus features, such that about 20% of the transmitted information corresponds to discriminating between different features, and the remaining 80% is used to allocate these features in time. In this spike-pattern code, the "what" and the "when" of the stimuli are encoded in the duration of each burst and the time of burst onset, respectively. Given the ubiquity of burst firing, we expect similar findings also for other neural systems.

  12. Fast Coding Unit Encoding Mechanism for Low Complexity Video Coding

    OpenAIRE

    Gao, Yuan; Liu, Pengyu; Wu, Yueying; Jia, Kebin; Gao, Guandong

    2016-01-01

    In high efficiency video coding (HEVC), coding tree contributes to excellent compression performance. However, coding tree brings extremely high computational complexity. Innovative works for improving coding tree to further reduce encoding time are stated in this paper. A novel low complexity coding tree mechanism is proposed for HEVC fast coding unit (CU) encoding. Firstly, this paper makes an in-depth study of the relationship among CU distribution, quantization parameter (QP) and content ...

  13. Assessing and Reducing Miscellaneous Electric Loads (MELs) in Banks

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Emily M.

    2012-09-01

    Miscellaneous electric loads (MELs) are loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. MELs are a large percentage of total building energy loads. This report reviews methods for reducing MELs in Banks. Reducing MELs in a bank setting requires both local and corporate action. Corporate action centers on activities to prioritize and allocate the right resources to correct procurement and central control issues. Local action includes branch assessment or audits to identify specific loads and needs. The worksheet at the end of this guide can help with cataloging needed information and estimating savings potential. The following steps provide a guide to MEL reductions in Bank Branches. The general process has been adapted from a process developed for office buildings the National Renewable Energy Laboratory (NREL, 2011).

  14. SAFIRE: A systems analysis code for ICF [inertial confinement fusion] reactor economics

    International Nuclear Information System (INIS)

    McCarville, T.J.; Meier, W.R.; Carson, C.F.; Glasgow, B.B.

    1987-01-01

    The SAFIRE (Systems Analysis for ICF Reactor Economics) code incorporates analytical models for scaling the cost and performance of several inertial confinement fusion reactor concepts for electric power. The code allows us to vary design parameters (e.g., driver energy, chamber pulse rate, net electric power) and evaluate the resulting change in capital cost of power plant and the busbar cost of electricity. The SAFIRE code can be used to identify the most attractive operating space and to identify those design parameters with the greatest leverage for improving the economics of inertial confinement fusion electric power plants

  15. Simulation of the thermal behaviour of electric industrial resistance furnaces using the I-DEAS/TMG code; Simulation du comportement thermique des fours electriques industriels a resistances a l`aide du code I-DEAS/TMG

    Energy Technology Data Exchange (ETDEWEB)

    Plard, Ch; Branchu, K; Le Cloirec, B [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches

    1997-12-31

    In order to answer the modeling needs of manufacturers and users of electrical resistance furnaces, Electricite de France (EdF) has been appealed to search for a numerical simulation tool for the modeling of thermal phenomena and to carry out its qualification. The TNG software has been retained according to its modeling characteristics of radiant heat transfers and to the coupling with thermal conduction. After a description of the main characteristics of this code, two examples of application to electrical furnaces are presented. The first example illustrates how it can be possible to accurately reproduce the behaviour of a big industrial furnace. The second example is an illustration of numerical simulation possibilities for the optimization of processes performed with an electric furnace. (J.S.)

  16. Simulation of the thermal behaviour of electric industrial resistance furnaces using the I-DEAS/TMG code; Simulation du comportement thermique des fours electriques industriels a resistances a l`aide du code I-DEAS/TMG

    Energy Technology Data Exchange (ETDEWEB)

    Plard, Ch.; Branchu, K.; Le Cloirec, B. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches

    1996-12-31

    In order to answer the modeling needs of manufacturers and users of electrical resistance furnaces, Electricite de France (EdF) has been appealed to search for a numerical simulation tool for the modeling of thermal phenomena and to carry out its qualification. The TNG software has been retained according to its modeling characteristics of radiant heat transfers and to the coupling with thermal conduction. After a description of the main characteristics of this code, two examples of application to electrical furnaces are presented. The first example illustrates how it can be possible to accurately reproduce the behaviour of a big industrial furnace. The second example is an illustration of numerical simulation possibilities for the optimization of processes performed with an electric furnace. (J.S.)

  17. Application of low bitrate image coding to surveillance of electric power facilities. Part 1. Proposal of low bitrate coding for surveillance of electric power facilities and examination of facilities region extraction method; Denryoku setsubi kanshi eno tei rate fugoka hoshiki no tekiyo. 1. Setsubi kanshiyo fugoka hoshiki no teian to setsubi ryoiki chushutsuho no kento

    Energy Technology Data Exchange (ETDEWEB)

    Murata, H.; Ishino, R. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-03-01

    Current status of low bitrate image coding has been investigated, and a low bitrate coding suitable for the surveillance of electric power facilities has been proposed, to extract its problems to be solved. For the conventional image coding, the waveform coding has been used by which the images are processed as signals. While, for the MPEG-4, a coding method with considering the image information has been proposed. For these coding methods, however, image information lacks details primarily, when lowering the bitrate. Accordingly, these methods can not be applied when the details in the images are important, such as in the case of surveillance of facilities. Then, the coding method has been proposed by expanding the partially detailed coding, and by separating constituent images of facilities, such as power cables and steel towers, designated by operators. It is the special feature of this method that the method can easily respond to the low bitrate and the detailed information can be conserved by using the structure extraction coding for the designated partial image which is generally processed by the low bitrate waveform coding. 29 refs., 17 figs., 1 tab.

  18. A lot left over: Reducing CO2 emissions in the United States’ electric power sector through the use of natural gas

    International Nuclear Information System (INIS)

    Lafrancois, Becky A.

    2012-01-01

    As the leading contributor of greenhouse gas emissions, the electricity sector stands to be impacted by policies seeking to curtail emissions. Instead of increasing electricity from renewable resources or nuclear power facilities, an alternative approach to reducing emissions in the electric power sector is changing the dispatch order of fossil fuels. Important differences between fossil fuels, and in the technologies used to burn them, make it possible to substantially reduce emissions from the sector. On average, each gigawatt-year of electricity generation switched from coal to natural gas reduces CO 2 emissions by 59 percent. As a result of significant investments in natural gas fired power plants in the United States between 1998 and 2005, there is an opportunity for electricity producers to take advantage of underutilized capacity. This is the first study to closely examine the new capital additions and analyze the technical potential for reductions in emissions. The analysis finds that 188 GW of capacity may be available to replace coal-fired baseload electricity generation. Utilizing this excess gas-fired capacity will reduce the sector's CO 2 emissions by 23 to 42 percent and reduce overall U.S. CO 2 emissions between 9 percent and 17 percent. - Highlights: ► Utilizing recently built natural gas fired power plants can significantly reduce CO 2 emissions in the United States. ► CO 2 emissions from electricity production can be reduced by 23–42 percent. ► U.S. overall CO 2 emissions reduced by 9–17 percent.

  19. The reduced basis method for the electric field integral equation

    International Nuclear Information System (INIS)

    Fares, M.; Hesthaven, J.S.; Maday, Y.; Stamm, B.

    2011-01-01

    We introduce the reduced basis method (RBM) as an efficient tool for parametrized scattering problems in computational electromagnetics for problems where field solutions are computed using a standard Boundary Element Method (BEM) for the parametrized electric field integral equation (EFIE). This combination enables an algorithmic cooperation which results in a two step procedure. The first step consists of a computationally intense assembling of the reduced basis, that needs to be effected only once. In the second step, we compute output functionals of the solution, such as the Radar Cross Section (RCS), independently of the dimension of the discretization space, for many different parameter values in a many-query context at very little cost. Parameters include the wavenumber, the angle of the incident plane wave and its polarization.

  20. Reducing lighting electricity use in underground metro stations

    International Nuclear Information System (INIS)

    Casals, Miquel; Gangolells, Marta; Forcada, Núria; Macarulla, Marcel

    2016-01-01

    Highlights: • Lighting systems are big energy consumers in underground metro stations. • An adaptive lighting system strategy is developed for underground stations. • Dimming controls are based on station occupancy levels and maintenance cycles. • The k-means clustering technique is used to identify stations’ occupancy patterns. • Savings were found to amount to 255.47 MW h in 2 years for a case study metro network. - Abstract: Lighting systems are usually one of the largest electrical end-uses in underground metro stations. Taking into account that budget restrictions in publicly owned companies hinder energy efficiency retrofit projects that require high initial investments, affordable energy saving strategies are needed. This paper presents a low-cost approach for reducing lighting electricity use in underground stations, without affecting passengers’ comfort or the metro operator’s service. For this purpose, an adaptive lighting strategy of dimming the illuminance levels of artificial light sources has been developed. Dimming controls are based on the occupancy of the station, and the preventive maintenance and cleaning cycles of the luminaires. The stations’ monthly occupancy patterns are defined through the k-means clustering technique. To illustrate its effectiveness, the method was applied to 115 underground stations of the Barcelona metro network. The results revealed overall electricity savings of 255.47 MW h on a biannual basis, which represents 36.22% of the stations’ baseline lighting consumption. Individual energy savings were found to range from 25 to 87.5 MW h/year in the stations of the Barcelona metro network, depending on the number and profile of station users. The research findings will undoubtedly be useful for the future energy efficiency project plans of worldwide metro operators and managers of other underground spaces.

  1. Electromagnetic reprogrammable coding-metasurface holograms.

    Science.gov (United States)

    Li, Lianlin; Jun Cui, Tie; Ji, Wei; Liu, Shuo; Ding, Jun; Wan, Xiang; Bo Li, Yun; Jiang, Menghua; Qiu, Cheng-Wei; Zhang, Shuang

    2017-08-04

    Metasurfaces have enabled a plethora of emerging functions within an ultrathin dimension, paving way towards flat and highly integrated photonic devices. Despite the rapid progress in this area, simultaneous realization of reconfigurability, high efficiency, and full control over the phase and amplitude of scattered light is posing a great challenge. Here, we try to tackle this challenge by introducing the concept of a reprogrammable hologram based on 1-bit coding metasurfaces. The state of each unit cell of the coding metasurface can be switched between '1' and '0' by electrically controlling the loaded diodes. Our proof-of-concept experiments show that multiple desired holographic images can be realized in real time with only a single coding metasurface. The proposed reprogrammable hologram may be a key in enabling future intelligent devices with reconfigurable and programmable functionalities that may lead to advances in a variety of applications such as microscopy, display, security, data storage, and information processing.Realizing metasurfaces with reconfigurability, high efficiency, and control over phase and amplitude is a challenge. Here, Li et al. introduce a reprogrammable hologram based on a 1-bit coding metasurface, where the state of each unit cell of the coding metasurface can be switched electrically.

  2. An Optimal Domestic Electric Vehicle Charging Strategy for Reducing Network Transmission Loss While Taking Seasonal Factors into Consideration

    Directory of Open Access Journals (Sweden)

    Yuancheng Zhao

    2018-01-01

    Full Text Available With the rapid growth of domestic electric vehicle charging loads, the peak-valley gap and power fluctuation rate of power systems increase sharply, which can lead to the increase of network losses and energy efficiency reduction. This paper tries to regulate network loads and reduce power system transmission loss by optimizing domestic electric vehicle charging loads. In this paper, a domestic electric vehicle charging loads model is first developed by analyzing the key factors that can affect users’ charging behavior. Subsequently, the Monte Carlo method is proposed to simulate the power consumption of a cluster of domestic electric vehicles. After that, an optimal electric vehicle charging strategy based on the 0-1 integer programming is presented to regulate network daily loads. Finally, by taking the IEEE33 distributed power system as an example, this paper tries to verify the efficacy of the proposed optimal charging strategy and the necessity for considering seasonal factors when scheduling electric vehicle charging loads. Simulation results show that the proposed 0-1 integer programming method does have good performance in reducing the network peak-valley gap, voltage fluctuation rate, and transmission loss. Moreover, it has some potential to further reduce power system transmission loss when seasonal factors are considered.

  3. Electrical Properties of Conductive Cotton Yarn Coated with Eosin Y Functionalized Reduced Graphene Oxide.

    Science.gov (United States)

    Kim, Eunju; Arul, Narayanasamy Sabari; Han, Jeong In

    2016-06-01

    This study reports the fabrication and investigation of the electrical properties of two types of conductive cotton yarns coated with eosin Y or eosin B functionalized reduced graphene (RGO) and bare graphene oxide (GO) using dip-coating method. The surface morphology of the conductive cotton yarn coated with reduced graphene oxide was observed by Scanning Electron Microscope (SEM). Due to the strong electrostatic attractive forces, the negatively charged surface such as the eosin Y functionalized reduced graphene oxide or bare GO can be easily coated to the positively charged polyethyleneimine (PEI) treated cotton yarn. The maximum current for the conductive cotton yarn coated with eosin Y functionalized RGO and bare GO with 20 cycles repetition of (5D + R) process was found to be 793.8 μA and 3482.8 μA. Our results showed that the electrical conductivity of bare GO coated conductive cotton yarn increased by approximately four orders of magnitude with the increase in the dipping cycle of (5D+R) process.

  4. Development of Nuclear Renewable Oil Shale Systems for Flexible Electricity and Reduced Fossil Fuel Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Curtis; Charles Forsberg; Humberto Garcia

    2015-05-01

    We propose the development of Nuclear Renewable Oil Shale Systems (NROSS) in northern Europe, China, and the western United States to provide large supplies of flexible, dispatchable, very-low-carbon electricity and fossil fuel production with reduced CO2 emissions. NROSS are a class of large hybrid energy systems in which base-load nuclear reactors provide the primary energy used to produce shale oil from kerogen deposits and simultaneously provide flexible, dispatchable, very-low-carbon electricity to the grid. Kerogen is solid organic matter trapped in sedimentary shale, and large reserves of this resource, called oil shale, are found in northern Europe, China, and the western United States. NROSS couples electricity generation and transportation fuel production in a single operation, reduces lifecycle carbon emissions from the fuel produced, improves revenue for the nuclear plant, and enables a major shift toward a very-low-carbon electricity grid. NROSS will require a significant development effort in the United States, where kerogen resources have never been developed on a large scale. In Europe, however, nuclear plants have been used for process heat delivery (district heating), and kerogen use is familiar in certain countries. Europe, China, and the United States all have the opportunity to use large scale NROSS development to enable major growth in renewable generation and either substantially reduce or eliminate their dependence on foreign fossil fuel supplies, accelerating their transitions to cleaner, more efficient, and more reliable energy systems.

  5. Reducing Energy Demand Using Wheel-Individual Electric Drives to Substitute EPS-Systems

    Directory of Open Access Journals (Sweden)

    Jürgen Römer

    2018-01-01

    Full Text Available The energy demand of vehicles is influenced, not only by the drive systems, but also by a number of add-on systems. Electric vehicles must satisfy this energy demand completely from the battery. Hence, the use of power steering systems directly result in a range reduction. The “e2-Lenk” joint project funded by the German Federal Ministry of Education and Research (BMBF involves a novel steering concept for electric vehicles to integrate the function of steering assistance into the drive-train. Specific distribution of driving torque at the steered axle allows the steering wheel torque to be influenced to support the steering force. This provides a potential for complete substitution of conventional power steering systems and reduces the vehicle’s energy demand. This paper shows the potential of wheel-individual drives influencing the driver’s steering torque using a control technique based on classical EPS control plans. Compared to conventional power-assisted steering systems, a reduced energy demand becomes evident over a wide range of operating conditions.

  6. Interface Control Document for the EMPACT Module that Estimates Electric Power Transmission System Response to EMP-Caused Damage

    Energy Technology Data Exchange (ETDEWEB)

    Werley, Kenneth Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mccown, Andrew William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)ory

    2016-06-26

    The EPREP code is designed to evaluate the effects of an Electro-Magnetic Pulse (EMP) on the electric power transmission system. The EPREP code embodies an umbrella framework that allows a user to set up analysis conditions and to examine analysis results. The code links to three major physics/engineering modules. The first module describes the EM wave in space and time. The second module evaluates the damage caused by the wave on specific electric power (EP) transmission system components. The third module evaluates the consequence of the damaged network on its (reduced) ability to provide electric power to meet demand. This third module is the focus of the present paper. The EMPACT code serves as the third module. The EMPACT name denotes EMP effects on Alternating Current Transmission systems. The EMPACT algorithms compute electric power transmission network flow solutions under severely damaged network conditions. Initial solutions are often characterized by unacceptible network conditions including line overloads and bad voltages. The EMPACT code contains algorithms to adjust optimally network parameters to eliminate network problems while minimizing outages. System adjustments include automatically adjusting control equipment (generator V control, variable transformers, and variable shunts), as well as non-automatic control of generator power settings and minimal load shedding. The goal is to evaluate the minimal loss of customer load under equilibrium (steady-state) conditions during peak demand.

  7. Energetic audit at the Hotel Punta Leona and solutions to reduce the spend in electricity

    International Nuclear Information System (INIS)

    Hernandez Madrigal, Tattiana; Gamboa Iglesias, Francisco Javier; Saenz Roldan, Esteban

    2013-01-01

    An energy audit is realized at the Hotel Punta Leona to determine the solutions in the reducing of the spend in electricity. The energy conservation opportunities are pointed in the rooms of Selvamar, Torremar, Arenas and Chalets. A system that stores, warms and distributes is identified in a optimal area to take advantage the solar energy. A storage system and food refrigeration are designed in the Restaurante Carabelas. Electricity consumption in different areas of the hotel and spend of potency of the household appliances of the rooms selected were measured with high technology equipment. Thermals leakages are analyzed by an infrared camera. The solar incidence taken advantage in the hotel facilities is determined. Topics such as energy audit, heat transfer, the sun and refrigeration systems are developed. Recommendations to reduce the electricity consumption in the areas studied are mentioned. An economic analysis is developed to justify the replacement of some equipment and the project profitability [es

  8. Signal processing methods for reducing artifacts in microelectrode brain recordings caused by functional electrical stimulation

    Science.gov (United States)

    Young, D.; Willett, F.; Memberg, W. D.; Murphy, B.; Walter, B.; Sweet, J.; Miller, J.; Hochberg, L. R.; Kirsch, R. F.; Ajiboye, A. B.

    2018-04-01

    Objective. Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain-computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. Approach. One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. Main results. Electrical artifacts resulting from surface stimulation were 175  ×  larger than baseline neural recordings (which were 110 µV peak-to-peak), while intramuscular stimulation artifacts were only 4  ×  larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µV and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. Significance. The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and

  9. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  10. Lost opportunities: Modeling commercial building energy code adoption in the United States

    International Nuclear Information System (INIS)

    Nelson, Hal T.

    2012-01-01

    This paper models the adoption of commercial building energy codes in the US between 1977 and 2006. Energy code adoption typically results in an increase in aggregate social welfare by cost effectively reducing energy expenditures. Using a Cox proportional hazards model, I test if relative state funding, a new, objective, multivariate regression-derived measure of government capacity, as well as a vector of control variables commonly used in comparative state research, predict commercial building energy code adoption. The research shows little political influence over historical commercial building energy code adoption in the sample. Colder climates and higher electricity prices also do not predict more frequent code adoptions. I do find evidence of high government capacity states being 60 percent more likely than low capacity states to adopt commercial building energy codes in the following year. Wealthier states are also more likely to adopt commercial codes. Policy recommendations to increase building code adoption include increasing access to low cost capital for the private sector and providing noncompetitive block grants to the states from the federal government. - Highlights: ► Model the adoption of commercial building energy codes from 1977–2006 in the US. ► Little political influence over historical building energy code adoption. ► High capacity states are over 60 percent more likely than low capacity states to adopt codes. ► Wealthier states are more likely to adopt commercial codes. ► Access to capital and technical assistance is critical to increase code adoption.

  11. Simulation of the preliminary General Electric SP-100 space reactor concept using the ATHENA computer code

    International Nuclear Information System (INIS)

    Fletcher, C.D.

    1986-01-01

    The capability to perform thermal-hydraulic analyses of a space reactor using the ATHENA computer code is demonstrated. The fast reactor, liquid-lithium coolant loops, and lithium-filled heat pipes of the preliminary General electric SP-100 design were modeled with ATHENA. Two demonstration transient calculations were performed simulating accident conditions. Calculated results are available for display using the Nuclear Plant Analyzer color graphics analysis tool in addition to traditional plots. ATHENA-calculated results appear reasonable, both for steady state full power conditions, and for the two transients. This analysis represents the first known transient thermal-hydraulic simulation using an integral space reactor system model incorporating heat pipes. 6 refs., 17 figs., 1 tab

  12. Multiple LDPC decoding for distributed source coding and video coding

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Luong, Huynh Van; Huang, Xin

    2011-01-01

    Distributed source coding (DSC) is a coding paradigm for systems which fully or partly exploit the source statistics at the decoder to reduce the computational burden at the encoder. Distributed video coding (DVC) is one example. This paper considers the use of Low Density Parity Check Accumulate...... (LDPCA) codes in a DSC scheme with feed-back. To improve the LDPC coding performance in the context of DSC and DVC, while retaining short encoder blocks, this paper proposes multiple parallel LDPC decoding. The proposed scheme passes soft information between decoders to enhance performance. Experimental...

  13. TRAC development at General Electric

    International Nuclear Information System (INIS)

    Andersen, J.G.M.; Shaug, J.C.; Shiralkar, B.S.

    1987-01-01

    TRAC is a computer code for transient analysis of light water reactors. The BWR version of TRAC has been developed as a result of a close cooperation between General Electric Company and Idaho National Engineering Laboratory. Up through 1985 the development work at General Electric was jointly funded by General Electric, the Nuclear Regulatory Commission and Electric Power Research Institute under the Refill-Reflood and FIST programs. At INEL (which has the main responsibility for the NRC version of TRAC-BWR) this work has led to the development of TRACBD1 and TRACBF1, while at GE, TRACB04 was the final product of the Refill-Reflood and FIST programs. TRAC development has continued at General Electric after the completion of these programs with the evolution of the TRACG code. The purpose of the paper is to describe this work. The TRAC development at General Electric can be divided into two main categories: extended benchmark capability and improved user convenience

  14. Public health benefits of strategies to reduce greenhouse-gas emissions: low-carbon electricity generation.

    Science.gov (United States)

    Markandya, Anil; Armstrong, Ben G; Hales, Simon; Chiabai, Aline; Criqui, Patrick; Mima, Silvana; Tonne, Cathryn; Wilkinson, Paul

    2009-12-12

    In this report, the third in this Series on health and climate change, we assess the changes in particle air pollution emissions and consequent effects on health that are likely to result from greenhouse-gas mitigation measures in the electricity generation sector in the European Union (EU), China, and India. We model the effect in 2030 of policies that aim to reduce total carbon dioxide (CO(2)) emissions by 50% by 2050 globally compared with the effect of emissions in 1990. We use three models: the POLES model, which identifies the distribution of production modes that give the desired CO(2) reductions and associated costs; the GAINS model, which estimates fine particulate matter with aerodynamic diameter 2.5 microm or less (PM(2.5)) concentrations; and a model to estimate the effect of PM(2.5) on mortality on the basis of the WHO's Comparative Risk Assessment methods. Changes in modes of production of electricity to reduce CO(2) emissions would, in all regions, reduce PM(2.5) and deaths caused by it, with the greatest effect in India and the smallest in the EU. Health benefits greatly offset costs of greenhouse-gas mitigation, especially in India where pollution is high and costs of mitigation are low. Our estimates are approximations but suggest clear health gains (co-benefits) through decarbonising electricity production, and provide additional information about the extent of such gains.

  15. A PIC-MCC code for simulation of streamer propagation in air

    DEFF Research Database (Denmark)

    Chanrion, Olivier Arnaud; Neubert, Torsten

    2008-01-01

    A particle code has been developed to study the distribution and acceleration of electrons in electric discharges in air. The code can follow the evolution of a discharge from the initial stage of a single free electron in a background electric field to the formation of an electron avalanche...... and its transition into a streamer. The code is in 2D axi-symmetric coordinates, allowing quasi 3D simulations during the initial stages of streamer formation. This is important for realistic simulations of problems where space charge fields are essential such as in streamer formation. The charged...... particles are followed in a Cartesian mesh and the electric field is updated with Poisson's equation from the charged particle densities. Collisional processes between electrons and air molecules are simulated with a Monte Carlo technique, according to cross section probabilities. The code also includes...

  16. Utility Sector Impacts of Reduced Electricity Demand

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, Katie

    2014-12-01

    This report presents a new approach to estimating the marginal utility sector impacts associated with electricity demand reductions. The method uses publicly available data and provides results in the form of time series of impact factors. The input data are taken from the Energy Information Agency's Annual Energy Outlook (AEO) projections of how the electric system might evolve in the reference case, and in a number of side cases that incorporate different effciency and other policy assumptions. The data published with the AEO are used to define quantitative relationships between demand-side electricity reductions by end use and supply-side changes to capacity by plant type, generation by fuel type and emissions of CO2, Hg, NOx and SO2. The impact factors define the change in each of these quantities per unit reduction in site electricity demand. We find that the relative variation in these impacts by end use is small, but the time variation can be significant.

  17. CONCEPT computer code

    International Nuclear Information System (INIS)

    Delene, J.

    1984-01-01

    CONCEPT is a computer code that will provide conceptual capital investment cost estimates for nuclear and coal-fired power plants. The code can develop an estimate for construction at any point in time. Any unit size within the range of about 400 to 1300 MW electric may be selected. Any of 23 reference site locations across the United States and Canada may be selected. PWR, BWR, and coal-fired plants burning high-sulfur and low-sulfur coal can be estimated. Multiple-unit plants can be estimated. Costs due to escalation/inflation and interest during construction are calculated

  18. Cellular and circuit properties supporting different sensory coding strategies in electric fish and other systems.

    Science.gov (United States)

    Marsat, Gary; Longtin, André; Maler, Leonard

    2012-08-01

    Neural codes often seem tailored to the type of information they must carry. Here we contrast the encoding strategies for two different communication signals in electric fish and describe the underlying cellular and network properties that implement them. We compare an aggressive signal that needs to be quickly detected, to a courtship signal whose quality needs to be evaluated. The aggressive signal is encoded by synchronized bursts and a predictive feedback input is crucial in separating background noise from the communication signal. The courtship signal is accurately encoded through a heterogenous population response allowing the discrimination of signal differences. Most importantly we show that the same strategies are used in other systems arguing that they evolved similar solutions because they faced similar tasks. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Electric fans for reducing adverse health impacts in heatwaves.

    Science.gov (United States)

    Gupta, Saurabh; Carmichael, Catriona; Simpson, Christina; Clarke, Mike J; Allen, Claire; Gao, Yang; Chan, Emily Y Y; Murray, Virginia

    2012-07-11

    Heatwaves are hot weather events, which breach regional or national thresholds, that last for several days. They are likely to occur with increasing frequency in some parts of the world. The potential consequences were illustrated in Europe in August 2003 when there were an estimated 30,000 excess deaths due to a heatwave. Electric fans might be used with the intention of reducing the adverse health effects of a heatwave. Fans do not cool the ambient air but can be used to draw in cooler air from outside when placed at an open window. The aim of the fans would be to increase heat loss by increasing the efficiency of all normal methods of heat loss, but particularly by evaporation and convection methods. However, it should be noted that increased sweating can lead to dehydration and electrolyte imbalances if these fluids and electrolytes are not replaced quickly enough. Research has also identified important gaps in knowledge about the use of fans, which might lead to their inappropriate use. To determine whether the use of electric fans contributes to, or impedes, heat loss at high ambient temperatures during a heatwave, and to contribute to the evidence base for the public health impacts of heatwaves. We sought unpublished and published studies that had been published in any language. The review team were able to assess studies reported in English, Chinese, Dutch, French and German; and reports in other languages would have been translated into English as necessary. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, the Indian biomedical literature (IndMED and MedIND) and databases of Chinese literature (Chinese Journal Net and Digital Periodical of WanFang Data). The most recent electronic searches were done in April 2012. We also checked the reference lists of relevant articles and the websites of relevant national and international organisations, and consulted with researchers and policy makers with experience in

  20. SYSTEM FOR AUTOMATIC SELECTION OF THE SPEED RATE OF ELECTRIC VEHICLES FOR REDUCING THE POWER CONSUMPTION

    Directory of Open Access Journals (Sweden)

    K. O. Soroka

    2017-06-01

    Full Text Available Purpose. The work is aimed to design a system for automatic selection of the optimal traffic modes and automatic monitoring of the electric energy consumption by electric transport. This automatic system should provide for the minimum energy expenses. Methodology. Current methodologies: 1 mathematical modeling of traffic modes of ground electric vehicles; 2 comparison of modelling results with the statistical monitoring; 3 system development for automatic choice of traffic modes of electric transport with minimal electrical energy consumptions taking into account the given route schedules and the limitations imposed by the general traffic rules. Findings. The authors obtained a mathematical dependency of the energy consumption by electric transport enterprises on the monthly averaged environment temperature was obtained. A system which allows for an automatic selection of the speed limit and provides automatic monitoring of the electrical energy consumption by electric vehicles was proposed in the form of local network, which works together with existing GPS system. Originality. A mathematical model for calculating the motion curves and energy consumption of electric vehicles has been developed. This model takes into account the characteristic values of the motor engine and the steering system, the change of the mass when loading or unloading passengers, the slopes and radii of the roads, the limitations given by the general traffic rules, and other factors. The dependency of the energy consumption on the averaged monthly environment temperature for public electric transport companies has been calculated. Practical value. The developed mathematical model simplifies the calculations of the traffic dynamics and energy consumption. It can be used for calculating the routing maps, for design and upgrade of the power networks, for development of the electricity saving measures. The system simplifies the work of the vehicle driver and allows reducing

  1. Fulcrum Network Codes

    DEFF Research Database (Denmark)

    2015-01-01

    Fulcrum network codes, which are a network coding framework, achieve three objectives: (i) to reduce the overhead per coded packet to almost 1 bit per source packet; (ii) to operate the network using only low field size operations at intermediate nodes, dramatically reducing complexity...... in the network; and (iii) to deliver an end-to-end performance that is close to that of a high field size network coding system for high-end receivers while simultaneously catering to low-end ones that can only decode in a lower field size. Sources may encode using a high field size expansion to increase...... the number of dimensions seen by the network using a linear mapping. Receivers can tradeoff computational effort with network delay, decoding in the high field size, the low field size, or a combination thereof....

  2. Accelerated electricity conservation in Juneau, Alaska: A study of household activities that reduced demand 25%

    International Nuclear Information System (INIS)

    Leighty, Wayne; Meier, Alan

    2011-01-01

    An avalanche destroyed the main hydroelectric transmission line to Juneau, Alaska in April, 2008. Diesel-generated electricity was substituted, causing electricity prices to increase 500% for 45 days. Electricity demand fell by 25% during the supply disruption. Most of the reduction occurred before the higher rates were implemented. Some conservation - about 8% of historic consumption - persisted after the transmission line was repaired and prices returned to normal. Consumers reduced energy use through a combination of new habits and technical improvements. A survey of residential consumers indicated that the average household undertook 10 conservation actions, with major changes in lighting, space heating, fuel switching, and water and appliance use. We propose a method for prioritizing conservation actions for promotion according to their impact in electricity savings (as a function of popularity, effectiveness, and persistence) and a dynamic framework for electricity use before, during, and after a supply disruption (i.e., both the magnitude and rates of change in electricity conservation). - Research highlights: → An electricity supply disruption caused prices to increase 500% for 45 days. → Electricity conservation of 25% occurred in a matter of days. → Electricity conservation of 8% persisted after the supply disruption was repaired. → Conservation occurred through behavior change and technology adoption. → The disruption induced consumers to try new behaviors that became new habits.

  3. Evaluation of electrical energy production patterns

    International Nuclear Information System (INIS)

    Conti, F.; Graziani, G.; Zanantoni, C.

    1975-06-01

    The main features and typical applications of the code TOTEM, developed by the CCR under request of DG XVII are described. The code is used to evaluate the physical and economical consequences of electrical power station installation policies. The input data are: the time-dependent electrical energy demand and its load duration curve, the physical and economical characteristics of the power stations, and the splitting of the energy between the various types of stations, apart from the energy produced by a plutonium burner and plutonium producer, which is calculated by the code. The output includes; costs, fuel consumption, separative work requirements

  4. Treatment and electricity harvesting from sulfate/sulfide-containing wastewaters using microbial fuel cell with enriched sulfate-reducing mixed culture

    International Nuclear Information System (INIS)

    Lee, Duu-Jong; Lee, Chin-Yu; Chang, Jo-Shu

    2012-01-01

    Highlights: ► We started up microbial fuel cell (MFC) using enriched sulfate-reducing mixed culture. ► Sulfate-reducing bacteria and anode-respiring bacteria were enriched in anodic biofilms. ► The MFC effectively remove sulfate to elementary sulfur in the presence of lactate. ► The present device can treat sulfate laden wastewaters with electricity harvesting. - Abstract: Anaerobic treatment of sulfate-laden wastewaters can produce excess sulfide, which is corrosive to pipelines and is toxic to incorporated microorganisms. This work started up microbial fuel cell (MFC) using enriched sulfate-reducing mixed culture as anodic biofilms and applied the so yielded MFC for treating sulfate or sulfide-laden wastewaters. The sulfate-reducing bacteria in anodic biofilm effectively reduced sulfate to sulfide, which was then used by neighboring anode respiring bacteria (ARB) as electron donor for electricity production. The presence of organic carbons enhanced MFC performance since the biofilm ARB were mixotrophs that need organic carbon to grow. The present device introduces a route for treating sulfate laden wastewaters with electricity harvesting.

  5. Treatment and electricity harvesting from sulfate/sulfide-containing wastewaters using microbial fuel cell with enriched sulfate-reducing mixed culture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Duu-Jong, E-mail: cedean@mail.ntust.edu.tw [Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan (China); Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan (China); Lee, Chin-Yu [Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan (China); Chang, Jo-Shu [Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan (China); Center for Bioscience and Biotechnology, National Cheng Kung University, Tainan, Taiwan (China); Research Center for Energy Technology and Strategy, National Cheng Kung University, Tainan, Taiwan (China)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We started up microbial fuel cell (MFC) using enriched sulfate-reducing mixed culture. Black-Right-Pointing-Pointer Sulfate-reducing bacteria and anode-respiring bacteria were enriched in anodic biofilms. Black-Right-Pointing-Pointer The MFC effectively remove sulfate to elementary sulfur in the presence of lactate. Black-Right-Pointing-Pointer The present device can treat sulfate laden wastewaters with electricity harvesting. - Abstract: Anaerobic treatment of sulfate-laden wastewaters can produce excess sulfide, which is corrosive to pipelines and is toxic to incorporated microorganisms. This work started up microbial fuel cell (MFC) using enriched sulfate-reducing mixed culture as anodic biofilms and applied the so yielded MFC for treating sulfate or sulfide-laden wastewaters. The sulfate-reducing bacteria in anodic biofilm effectively reduced sulfate to sulfide, which was then used by neighboring anode respiring bacteria (ARB) as electron donor for electricity production. The presence of organic carbons enhanced MFC performance since the biofilm ARB were mixotrophs that need organic carbon to grow. The present device introduces a route for treating sulfate laden wastewaters with electricity harvesting.

  6. Fast code for Monte Carlo simulations

    International Nuclear Information System (INIS)

    Oliveira, P.M.C. de; Penna, T.J.P.

    1988-01-01

    A computer code to generate the dynamic evolution of the Ising model on a square lattice, following the Metropolis algorithm is presented. The computer time consumption is reduced by a factor of 8 when one compares our code with traditional multiple spin codes. The memory allocation size is also reduced by a factor of 4. The code is easily generalizable for other lattices and models. (author) [pt

  7. Induction technology optimization code

    International Nuclear Information System (INIS)

    Caporaso, G.J.; Brooks, A.L.; Kirbie, H.C.

    1992-01-01

    A code has been developed to evaluate relative costs of induction accelerator driver systems for relativistic klystrons. The code incorporates beam generation, transport and pulsed power system constraints to provide an integrated design tool. The code generates an injector/accelerator combination which satisfies the top level requirements and all system constraints once a small number of design choices have been specified (rise time of the injector voltage and aspect ratio of the ferrite induction cores, for example). The code calculates dimensions of accelerator mechanical assemblies and values of all electrical components. Cost factors for machined parts, raw materials and components are applied to yield a total system cost. These costs are then plotted as a function of the two design choices to enable selection of an optimum design based on various criteria. (Author) 11 refs., 3 figs

  8. Technical and operational organisation of the 'Swiss Marketplace': GridCode CH

    International Nuclear Information System (INIS)

    Imhof, K.; Baumann, R.

    2001-01-01

    This article describes the minimum requirements placed on the operators of electricity grids by the planned Swiss Electricity Market Law. These are compiled in the Swiss Grid Code - GridCode CH. The various players in an open electricity market such as generating companies, power brokers, those responsible for balance groups, grid operators, system co-ordinators, the operators of fine distribution networks and the final consumer and the roles they play are examined. The history of the development of the Grid Code, which contains technical and operational regulations for the successful co-operation of the market players, is reviewed. The contractual obligations of the partners involved and, in particular, regulations concerning metering, measured value designation and the provision of data are discussed

  9. Code Recognition Device for Automobile, a Panacea for Automobiles Theft

    Directory of Open Access Journals (Sweden)

    Ozomata David AHMED

    2011-06-01

    Full Text Available Code Recognition Device is a security device for automobiles. It responds only to the right sequence of codes that are keyed from the key pad. This closes the electrical circuitry of the automobile and enables it to start. If a wrong key is touched, it resets the device which disengages the electrical circuit of the automobile from the power supply. The device works properly on closing all the doors of the automobile, otherwise it cannot start. Also, once the automobile is in operation, opening of any door will disengage the device and the engine will stop. To restart the engine, the doors must be closed and the codes rendered sequentially-in this case the codes are 1974.

  10. Energy Management Systems to Reduce Electrical Energy Consumption

    OpenAIRE

    Oriti, Giovanna

    2015-01-01

    EXECUTIVE SUMMARY An energy management system comprises an electrical energy storage element such as a battery, renewable electrical energy sources such as solar and wind, a digital signal processing controller and a solid state power converter to interface the elements together. This hardware demonstration in the lab at the Naval Postgraduate School will focus on solid state power conversion methods to improve the reliability and efficiency of electrical energy consumption by Navy facilit...

  11. High current density, cryogenically cooled sliding electrical joint development

    International Nuclear Information System (INIS)

    Murray, H.

    1986-09-01

    In the past two years, conceptual designs for fusion energy research devices have focussed on compact, high magnetic field configurations. The concept of sliding electrical joints in the large magnets allows a number of technical advantages including enhanced mechanical integrity, remote maintainability, and reduced project cost. The rationale for sliding electrical joints is presented. The conceptual configuration for this generation of experimental devices is highlghted by an ∼ 20 T toroidal field magnet with a flat top conductor current of ∼ 300 kA and a sliding electrical joint with a gross current density of ∼ 0.6 kA/cm 2 . A numerical model was used to map the conductor current distribution as a function of time and position in the conductor. A series of electrical joint arrangements were produced against the system code envelope constraints for a specific version of the Ignition Studies Project (ISP) which is designated as 1025

  12. Dexter - A one-dimensional code for calculating thermionic performance of long converters.

    Science.gov (United States)

    Sawyer, C. D.

    1971-01-01

    This paper describes a versatile code for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are given.

  13. Approaches for Reduced Order Modeling of Electrically Actuated von Karman Microplates

    KAUST Repository

    Saghir, Shahid

    2016-07-25

    This article presents and compares different approaches to develop reduced order models for the nonlinear von Karman rectangular microplates actuated by nonlinear electrostatic forces. The reduced-order models aim to investigate the static and dynamic behavior of the plate under small and large actuation forces. A fully clamped microplate is considered. Different types of basis functions are used in conjunction with the Galerkin method to discretize the governing equations. First we investigate the convergence with the number of modes retained in the model. Then for validation purpose, a comparison of the static results is made with the results calculated by a nonlinear finite element model. The linear eigenvalue problem for the plate under the electrostatic force is solved for a wide range of voltages up to pull-in. Results among the various reduced-order modes are compared and are also validated by comparing to results of the finite-element model. Further, the reduced order models are employed to capture the forced dynamic response of the microplate under small and large vibration amplitudes. Comparison of the different approaches are made for this case. Keywords: electrically actuated microplates, static analysis, dynamics of microplates, diaphragm vibration, large amplitude vibrations, nonlinear dynamics

  14. Tax barriers to four renewable electric generation technologies

    International Nuclear Information System (INIS)

    Jenkins, A.F.; Chapman, R.A.; Reilly, H.E.

    1996-01-01

    The tax loads associated with constructing and owning current and advanced solar central receiver, biomass-electric, and flash and binary cycle geothermal projects are compared to the tax loads incurred by natural gas-fired generation matched in size, hours of operation, and technology status. All but one of the eight renewable projects carry higher tax burdens under current tax codes. These higher tax loads proportionately reduce the competitiveness of renewables. Three tax neutralizing policies are applied to the renewable projects, each restoring competitiveness for some of the projects. The results show that RD and D must be accompanied with such public initiatives as tax neutrality in order for the majority of renewable projects to compete with advanced gas turbines in the emerging electric services market

  15. Color Coding of Circuit Quantities in Introductory Circuit Analysis Instruction

    Science.gov (United States)

    Reisslein, Jana; Johnson, Amy M.; Reisslein, Martin

    2015-01-01

    Learning the analysis of electrical circuits represented by circuit diagrams is often challenging for novice students. An open research question in electrical circuit analysis instruction is whether color coding of the mathematical symbols (variables) that denote electrical quantities can improve circuit analysis learning. The present study…

  16. Benchmark test of drift-kinetic and gyrokinetic codes through neoclassical transport simulations

    International Nuclear Information System (INIS)

    Satake, S.; Sugama, H.; Watanabe, T.-H.; Idomura, Yasuhiro

    2009-09-01

    Two simulation codes that solve the drift-kinetic or gyrokinetic equation in toroidal plasmas are benchmarked by comparing the simulation results of neoclassical transport. The two codes are the drift-kinetic δf Monte Carlo code (FORTEC-3D) and the gyrokinetic full- f Vlasov code (GT5D), both of which solve radially-global, five-dimensional kinetic equation with including the linear Fokker-Planck collision operator. In a tokamak configuration, neoclassical radial heat flux and the force balance relation, which relates the parallel mean flow with radial electric field and temperature gradient, are compared between these two codes, and their results are also compared with the local neoclassical transport theory. It is found that the simulation results of the two codes coincide very well in a wide rage of plasma collisionality parameter ν * = 0.01 - 10 and also agree with the theoretical estimations. The time evolution of radial electric field and particle flux, and the radial profile of the geodesic acoustic mode frequency also coincide very well. These facts guarantee the capability of GT5D to simulate plasma turbulence transport with including proper neoclassical effects of collisional diffusion and equilibrium radial electric field. (author)

  17. Method of imaging the electrical conductivity distribution of a subsurface

    Science.gov (United States)

    Johnson, Timothy C.

    2017-09-26

    A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

  18. Use of computer codes for system reliability analysis

    International Nuclear Information System (INIS)

    Sabek, M.; Gaafar, M.; Poucet, A.

    1989-01-01

    This paper gives a summary of studies performed at the JRC, ISPRA on the use of computer codes for complex systems analysis. The computer codes dealt with are: CAFTS-SALP software package, FRACTIC, FTAP, computer code package RALLY, and BOUNDS. Two reference case studies were executed by each code. The probabilistic results obtained, as well as the computation times are compared. The two cases studied are the auxiliary feedwater system of a 1300 MW PWR reactor and the emergency electrical power supply system. (author)

  19. Use of computer codes for system reliability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sabek, M.; Gaafar, M. (Nuclear Regulatory and Safety Centre, Atomic Energy Authority, Cairo (Egypt)); Poucet, A. (Commission of the European Communities, Ispra (Italy). Joint Research Centre)

    1989-01-01

    This paper gives a summary of studies performed at the JRC, ISPRA on the use of computer codes for complex systems analysis. The computer codes dealt with are: CAFTS-SALP software package, FRACTIC, FTAP, computer code package RALLY, and BOUNDS. Two reference case studies were executed by each code. The probabilistic results obtained, as well as the computation times are compared. The two cases studied are the auxiliary feedwater system of a 1300 MW PWR reactor and the emergency electrical power supply system. (author).

  20. DEXTER: A one-dimensional code for calculating thermionic performance of long converters

    Science.gov (United States)

    Sawyer, C. D.

    1971-01-01

    A versatile code is described for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are included along with a user's manual.

  1. 'BACO' code: Cogeneration cycles heat balance

    International Nuclear Information System (INIS)

    Huelamo Martinez, E.; Conesa Lopez, P.; Garcia Kilroy, P.

    1993-01-01

    This paper presents a code, developed by Empresarios Agrupados, sponsored by OCIDE, CSE and ENHER, that, with Electrical Utilities as final users, allows to make combined and cogeneration cycles technical-economical studies. (author)

  2. Enhanced ordering reduces electric susceptibility of liquids confined to graphene slit pores

    Science.gov (United States)

    Terrones, Jeronimo; Kiley, Patrick J.; Elliott, James A.

    2016-01-01

    The behaviours of a range of polar and non-polar organic liquids (acetone, ethanol, methanol, N-methyl-2-pyrrolidone (NMP), carbon tetrachloride and water) confined to 2D graphene nanochannels with thicknesses in the range of 4.5 Å to 40 Å were studied using classical molecular dynamics and hybrid density functional theory. All liquids were found to organise spontaneously into ordered layers parallel to the confining surfaces, with those containing polar molecules having their electric dipoles aligned parallel to such surfaces. In particular, monolayers of NMP showed remarkable in-plane ordering and low molecular mobility, suggesting the existence of a previously unknown 2D solid-like phase. Calculations for polar liquids showed dramatically reduced static permittivities normal to the confining surfaces; these changes are expected to improve electron tunnelling across the liquid films, modifying the DC electrical properties of immersed assemblies of carbon nanomaterials. PMID:27265098

  3. Additional extensions to the NASCAP computer code, volume 3

    Science.gov (United States)

    Mandell, M. J.; Cooke, D. L.

    1981-01-01

    The ION computer code is designed to calculate charge exchange ion densities, electric potentials, plasma temperatures, and current densities external to a neutralized ion engine in R-Z geometry. The present version assumes the beam ion current and density to be known and specified, and the neutralizing electrons to originate from a hot-wire ring surrounding the beam orifice. The plasma is treated as being resistive, with an electron relaxation time comparable to the plasma frequency. Together with the thermal and electrical boundary conditions described below and other straightforward engine parameters, these assumptions suffice to determine the required quantities. The ION code, written in ASCII FORTRAN for UNIVAC 1100 series computers, is designed to be run interactively, although it can also be run in batch mode. The input is free-format, and the output is mainly graphical, using the machine-independent graphics developed for the NASCAP code. The executive routine calls the code's major subroutines in user-specified order, and the code allows great latitude for restart and parameter change.

  4. Incorporation of polydimethylsiloxane with reduced graphene oxide and zinc oxide for tensile and electrical properties

    Science.gov (United States)

    Danial, N. S.; Ramli, Muhammad. M.; Halin, D. S. C.; Hong, H. C.; Isa, S. Salwa M.; Abdullah, M. M. A. B.; Anhar, N. A. M.; Talip, L. F. A.; Mazlan, N. S.

    2017-09-01

    Polydimethylsiloxane (PDMS) is an organosilicon polymer that is commonly used to incorporate with other fillers. PDMS in high viscous liquid form is mechanically stirred with reduced graphene oxide (rGO) and mixed with zinc oxide (ZnO) with specific ratio, thus rendering into two types of samples. The mechanical and electrical properties of both samples are characterized. The result shows that PDMS sample with 50 mg rGO has the highest tensile strength with the value of 9.1 MPa. For electrical properties, sample with the lowest resistance is PDMS with 50 mg rGO and ZnO with the value of l.67×l05 Ω. This experiment shows the significant role of conductive fillers like rGO and ZnO incorporated in polymeric material such as PDMS to improve its electrical properties.

  5. Does electrical stimulation reduce spasticity after stroke? A randomized controlled study.

    Science.gov (United States)

    Bakhtiary, Amir H; Fatemy, Elham

    2008-05-01

    To investigate the therapeutic effect of electrical stimulation on plantarflexor spasticity in stroke patients. A randomized controlled clinical trial study. Rehabilitation clinic of Semnan University of Medical Sciences. Forty stroke patients (aged from 42 to 65 years) with ankle plantarflexor spasticity. Fifteen minutes of inhibitory Bobath techniques were applied to one experimental group and a combination of 9 minutes of electrical stimulation on the dorsiflexor muscles and inhibitory Bobath techniques was applied to another group for 20 sessions daily. Passive ankle joint dorsiflexion range of motion, dorsiflexion strength test, plantarflexor muscle tone by Modified Ashworth Scale and soleus muscle H-reflex. The mean change of passive ankle joint dorsiflexion in the combination therapy group was 11.4 (SD 4.79) degrees versus 6.1 (SD 3.09) degrees, which was significantly higher (P = 0.001). The mean change of plantarflexor muscle tonicity measured by the Modified Ashworth Scale in the combination therapy group was -1.6 (SD 0.5) versus -1.1 (SD 0.31) in the Bobath group (P = 0.001). Dorsiflexor muscle strength was also increased significantly (P = 0.04) in the combination therapy group (0.7 +/- 0.37) compared with the Bobath group (0.4 +/- 0.23). However, no significant change in the amplitude of H-reflex was found between combination therapy (-0.41 +/- 0.29) and Bobath (-0.3 +/- 0.28) groups. Therapy combining Bobath inhibitory technique and electrical stimulation may help to reduce spasticity effectively in stroke patients.

  6. Structure, temperature and frequency dependent electrical conductivity of oxidized and reduced electrochemically exfoliated graphite

    Science.gov (United States)

    Radoń, Adrian; Włodarczyk, Patryk; Łukowiec, Dariusz

    2018-05-01

    The article presents the influence of reduction by hydrogen in statu nascendi and modification by hydrogen peroxide on the structure and electrical conductivity of electrochemically exfoliated graphite. It was confirmed that the electrochemical exfoliation can be used to produce oxidized nanographite with an average number of 25 graphene layers. The modified electrochemical exfoliated graphite and reduced electrochemical exfoliated graphite were characterized by high thermal stability, what was associated with removing of labile oxygen-containing groups. The presence of oxygen-containing groups was confirmed using Fourier-transform infrared spectroscopy. Influence of chemical modification by hydrogen and hydrogen peroxide on the electrical conductivity was determined in wide frequency (0.1 Hz-10 kHz) and temperature range (-50 °C-100 °C). Material modified by hydrogen peroxide (0.29 mS/cm at 0 °C) had the lowest electrical conductivity. This can be associated with oxidation of unstable functional groups and was also confirmed by analysis of Raman spectra. The removal of oxygen-containing functional groups by hydrogen in statu nascendi resulted in a 1000-fold increase in the electrical conductivity compared to the electrochemical exfoliated graphite.

  7. Finite element methods in a simulation code for offshore wind turbines

    Science.gov (United States)

    Kurz, Wolfgang

    1994-06-01

    Offshore installation of wind turbines will become important for electricity supply in future. Wind conditions above sea are more favorable than on land and appropriate locations on land are limited and restricted. The dynamic behavior of advanced wind turbines is investigated with digital simulations to reduce time and cost in development and design phase. A wind turbine can be described and simulated as a multi-body system containing rigid and flexible bodies. Simulation of the non-linear motion of such a mechanical system using a multi-body system code is much faster than using a finite element code. However, a modal representation of the deformation field has to be incorporated in the multi-body system approach. The equations of motion of flexible bodies due to deformation are generated by finite element calculations. At Delft University of Technology the simulation code DUWECS has been developed which simulates the non-linear behavior of wind turbines in time domain. The wind turbine is divided in subcomponents which are represented by modules (e.g. rotor, tower etc.).

  8. Lattices applied to coding for reliable and secure communications

    CERN Document Server

    Costa, Sueli I R; Campello, Antonio; Belfiore, Jean-Claude; Viterbo, Emanuele

    2017-01-01

    This book provides a first course on lattices – mathematical objects pertaining to the realm of discrete geometry, which are of interest to mathematicians for their structure and, at the same time, are used by electrical and computer engineers working on coding theory and cryptography. The book presents both fundamental concepts and a wealth of applications, including coding and transmission over Gaussian channels, techniques for obtaining lattices from finite prime fields and quadratic fields, constructions of spherical codes, and hard lattice problems used in cryptography. The topics selected are covered in a level of detail not usually found in reference books. As the range of applications of lattices continues to grow, this work will appeal to mathematicians, electrical and computer engineers, and graduate or advanced undergraduate in these fields.

  9. A reduced complexity highly power/bandwidth efficient coded FQPSK system with iterative decoding

    Science.gov (United States)

    Simon, M. K.; Divsalar, D.

    2001-01-01

    Based on a representation of FQPSK as a trellis-coded modulation, this paper investigates the potential improvement in power efficiency obtained from the application of simple outer codes to form a concatenated coding arrangement with iterative decoding.

  10. Reducing the electricity consumption of small ventilation installations; Reduktion des Elektrizitaetsverbrauchs von Klein-Lueftungsanlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Furter, R.; Casartelli, E.; Lang, M.

    2010-03-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at how the electricity consumption of small ventilation installations can be reduced. Residential ventilation systems - also known as comfort ventilation systems - have to fulfil demands placed on energy efficiency, comfort and hygiene. The results of exemplary measurements of the electrical power consumption that have been made in order to estimate the current situation of ventilation systems and of air handling units in apartments and single family houses are presented and discussed. Air networks were simulated at nominal air flow with different pressure losses for nine different ventilation units. The most important conclusion of this work is quoted as being that the internal pressure losses of the ventilation units have to be reduced and the design recommendation for the air network has to be reconsidered. Also the authors are of the opinion that hygiene requirements must be more rigorously respected.

  11. The UK core performance code package

    International Nuclear Information System (INIS)

    Hutt, P.K.; Gaines, N.; McEllin, M.; White, R.J.; Halsall, M.J.

    1991-01-01

    Over the last few years work has been co-ordinated by Nuclear Electric, originally part of the Central Electricity Generating Board, with contributions from the United Kingdom Atomic Energy Authority and British Nuclear Fuels Limited, to produce a generic, easy-to-use and integrated package of core performance codes able to perform a comprehensive range of calculations for fuel cycle design, safety analysis and on-line operational support for Light Water Reactor and Advanced Gas Cooled Reactor plant. The package consists of modern rationalized generic codes for lattice physics (WIMS), whole reactor calculations (PANTHER), thermal hydraulics (VIPRE) and fuel performance (ENIGMA). These codes, written in FORTRAN77, are highly portable and new developments have followed modern quality assurance standards. These codes can all be run ''stand-alone'' but they are also being integrated within a new UNIX-based interactive system called the Reactor Physics Workbench (RPW). The RPW provides an interactive user interface and a sophisticated data management system. It offers quality assurance features to the user and has facilities for defining complex calculational sequences. The Paper reviews the current capabilities of these components, their integration within the package and outlines future developments underway. Finally, the Paper describes the development of an on-line version of this package which is now being commissioned on UK AGR stations. (author)

  12. Coding for Electronic Mail

    Science.gov (United States)

    Rice, R. F.; Lee, J. J.

    1986-01-01

    Scheme for coding facsimile messages promises to reduce data transmission requirements to one-tenth current level. Coding scheme paves way for true electronic mail in which handwritten, typed, or printed messages or diagrams sent virtually instantaneously - between buildings or between continents. Scheme, called Universal System for Efficient Electronic Mail (USEEM), uses unsupervised character recognition and adaptive noiseless coding of text. Image quality of resulting delivered messages improved over messages transmitted by conventional coding. Coding scheme compatible with direct-entry electronic mail as well as facsimile reproduction. Text transmitted in this scheme automatically translated to word-processor form.

  13. The Architecture Design of Detection and Calibration System for High-voltage Electrical Equipment

    Science.gov (United States)

    Ma, Y.; Lin, Y.; Yang, Y.; Gu, Ch; Yang, F.; Zou, L. D.

    2018-01-01

    With the construction of Material Quality Inspection Center of Shandong electric power company, Electric Power Research Institute takes on more jobs on quality analysis and laboratory calibration for high-voltage electrical equipment, and informationization construction becomes urgent. In the paper we design a consolidated system, which implements the electronic management and online automation process for material sampling, test apparatus detection and field test. In the three jobs we use QR code scanning, online Word editing and electronic signature. These techniques simplify the complex process of warehouse management and testing report transferring, and largely reduce the manual procedure. The construction of the standardized detection information platform realizes the integrated management of high-voltage electrical equipment from their networking, running to periodic detection. According to system operation evaluation, the speed of transferring report is doubled, and querying data is also easier and faster.

  14. On decoding of multi-level MPSK modulation codes

    Science.gov (United States)

    Lin, Shu; Gupta, Alok Kumar

    1990-01-01

    The decoding problem of multi-level block modulation codes is investigated. The hardware design of soft-decision Viterbi decoder for some short length 8-PSK block modulation codes is presented. An effective way to reduce the hardware complexity of the decoder by reducing the branch metric and path metric, using a non-uniform floating-point to integer mapping scheme, is proposed and discussed. The simulation results of the design are presented. The multi-stage decoding (MSD) of multi-level modulation codes is also investigated. The cases of soft-decision and hard-decision MSD are considered and their performance are evaluated for several codes of different lengths and different minimum squared Euclidean distances. It is shown that the soft-decision MSD reduces the decoding complexity drastically and it is suboptimum. The hard-decision MSD further simplifies the decoding while still maintaining a reasonable coding gain over the uncoded system, if the component codes are chosen properly. Finally, some basic 3-level 8-PSK modulation codes using BCH codes as component codes are constructed and their coding gains are found for hard decision multistage decoding.

  15. A simple in-surge pressure analysis using the SPACE code

    International Nuclear Information System (INIS)

    Youn, Bum Soo; Kim, Yo Han; Lee, Dong Hyuk; Yang, Chang Keun; Kim, Se Yun; Ha, Sang Jun

    2010-01-01

    Currently, nuclear safety analysis codes used in Korea are developed by all the overseas. These codes are paying huge fee and permission must be obtained for use in the country. In addition, orders for nuclear power plants must ensure the safety analysis code for independent domestic technology. Therefore, Korea Electric Power Research Institute(KEPRI) is developing the domestic nuclear power safety analysis, SPACE(Safety and Performance Analysis Code for nuclear power plants). To determine the computational power of pressurizer model in development SPACE code, it was compared with existing commercial nuclear power safety analysis code, RETRAN

  16. Quick response codes in Orthodontics

    Directory of Open Access Journals (Sweden)

    Moidin Shakil

    2015-01-01

    Full Text Available Quick response (QR code codes are two-dimensional barcodes, which encodes for a large amount of information. QR codes in Orthodontics are an innovative approach in which patient details, radiographic interpretation, and treatment plan can be encoded. Implementing QR code in Orthodontics will save time, reduces paperwork, and minimizes manual efforts in storage and retrieval of patient information during subsequent stages of treatment.

  17. Design of convolutional tornado code

    Science.gov (United States)

    Zhou, Hui; Yang, Yao; Gao, Hongmin; Tan, Lu

    2017-09-01

    As a linear block code, the traditional tornado (tTN) code is inefficient in burst-erasure environment and its multi-level structure may lead to high encoding/decoding complexity. This paper presents a convolutional tornado (cTN) code which is able to improve the burst-erasure protection capability by applying the convolution property to the tTN code, and reduce computational complexity by abrogating the multi-level structure. The simulation results show that cTN code can provide a better packet loss protection performance with lower computation complexity than tTN code.

  18. Recent activities on nuclear codes and standards

    International Nuclear Information System (INIS)

    Minematsu, Akiyoshi; Ishimoto, Shozaburo; Honjin, Masao

    2000-01-01

    The technical codes and standards relating to the nuclear power stations in Japan are prepared by shapes of laws (ministerial ordinances and bulletins) issued by the government and obliged to comply with by 'the Law concerning the Regulations of Nuclear Material Substances, Nuclear Fuel Substances and Nuclear Reactors' and 'the Electricity Business Act' and of guides defined by the Nuclear Safety Commission, and further some private standards have been issued at a shape of complement of these laws and guides by receiving national recommendation. On the other hand, in the fields of electricity and heat facilities except atomic energy, simplification and feature stipulation of the national technical codes and standards was recently carried out, by which a system usable for the private standards in and out of Japan were prepared through approval of the private Japan Electrotechnical Standards and Codes Committee (JESC). As the nuclear field was now excepted from simultaneous transfer to the private standard and the standard application system, it is expected in future to realize similar transfer if possible and preparation of the private standards is now being advanced. Here were introduced on present state on technical codes and standards relating to the nuclear power generation facilities and recent trends on their private standardization. (G.K.)

  19. Studies on synthesis of reduced graphene oxide (RGO) via green route and its electrical property

    Energy Technology Data Exchange (ETDEWEB)

    Sadhukhan, Sourav [Department of Polymer Science and Technology, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India); Department of Chemistry, Budge Budge Institute of Technology, Nischintapur, Budge Budge, Kolkata 700137 (India); Ghosh, Tapas Kumar [Department of Polymer Science and Technology, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India); Department of Chemistry, West Bengal State University, Barasat, Kolkata 700126 (India); Rana, Dipak [Department of Chemical and Biological Engineering, Industrial Membrane Research Institute, University of Ottawa, 161 Louis Pasteur St., Ottawa, Ontario K1 N 6N5 (Canada); Roy, Indranil; Bhattacharyya, Amartya; Sarkar, Gunjan [Department of Polymer Science and Technology, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India); Chakraborty, Mukut [Department of Chemistry, West Bengal State University, Barasat, Kolkata 700126 (India); Chattopadhyay, Dipankar, E-mail: dipankar.chattopadhyay@gmail.com [Department of Polymer Science and Technology, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India)

    2016-07-15

    Highlights: • RGO-1 and RGO-2 were synthesized by green method using different phytoextracts. • M. indica L., S. tuberosum L. phytoextracts act as reducing and stabilizing agents. • Conjugated structure of graphene is established following partial reduction of GO. • Electrical conductivities of RGO-1 and RGO-2 are higher than GO. - Abstract: An environmentally friendly method has been applied for the preparation of reduced graphene oxide (RGO). This method was developed by using polyphenols that contained a phytoextract of Mangifera indica L. along with Solanum tuberosum L. as reducing agents since they are non-toxic and naturally available. The phytoextracts used in the production of RGO was set between 60 and 70 °C. Graphene oxide (GO) was prepared by modified Hummer’s method as reported in earlier findings. Structural and morphological studies demonstrate that the part of the oxygen functionalities in GO can be removed by following green reduction. Characterizations of the resulting product have been done by X-ray diffraction, FTIR, UV–vis and Raman spectroscopy. FESEM, TEM, EDX spectrum, TGA, DLS and Zeta potential measurements of the samples have also been carried out to study the morphological, thermal and surface charge characteristics. Electrical conductivity was also measured to check the extent of reduction of GO to RGO.

  20. Studies on synthesis of reduced graphene oxide (RGO) via green route and its electrical property

    International Nuclear Information System (INIS)

    Sadhukhan, Sourav; Ghosh, Tapas Kumar; Rana, Dipak; Roy, Indranil; Bhattacharyya, Amartya; Sarkar, Gunjan; Chakraborty, Mukut; Chattopadhyay, Dipankar

    2016-01-01

    Highlights: • RGO-1 and RGO-2 were synthesized by green method using different phytoextracts. • M. indica L., S. tuberosum L. phytoextracts act as reducing and stabilizing agents. • Conjugated structure of graphene is established following partial reduction of GO. • Electrical conductivities of RGO-1 and RGO-2 are higher than GO. - Abstract: An environmentally friendly method has been applied for the preparation of reduced graphene oxide (RGO). This method was developed by using polyphenols that contained a phytoextract of Mangifera indica L. along with Solanum tuberosum L. as reducing agents since they are non-toxic and naturally available. The phytoextracts used in the production of RGO was set between 60 and 70 °C. Graphene oxide (GO) was prepared by modified Hummer’s method as reported in earlier findings. Structural and morphological studies demonstrate that the part of the oxygen functionalities in GO can be removed by following green reduction. Characterizations of the resulting product have been done by X-ray diffraction, FTIR, UV–vis and Raman spectroscopy. FESEM, TEM, EDX spectrum, TGA, DLS and Zeta potential measurements of the samples have also been carried out to study the morphological, thermal and surface charge characteristics. Electrical conductivity was also measured to check the extent of reduction of GO to RGO.

  1. Bar codes for nuclear safeguards

    International Nuclear Information System (INIS)

    Keswani, A.N.; Bieber, A.M. Jr.

    1983-01-01

    Bar codes similar to those used in supermarkets can be used to reduce the effort and cost of collecting nuclear materials accountability data. A wide range of equipment is now commercially available for printing and reading bar-coded information. Several examples of each of the major types of commercially available equipment are given, and considerations are discussed both for planning systems using bar codes and for choosing suitable bar code equipment

  2. Bar codes for nuclear safeguards

    International Nuclear Information System (INIS)

    Keswani, A.N.; Bieber, A.M.

    1983-01-01

    Bar codes similar to those used in supermarkets can be used to reduce the effort and cost of collecting nuclear materials accountability data. A wide range of equipment is now commercially available for printing and reading bar-coded information. Several examples of each of the major types of commercially-available equipment are given, and considerations are discussed both for planning systems using bar codes and for choosing suitable bar code equipment

  3. An economic analysis code used for PWR fuel cycle

    International Nuclear Information System (INIS)

    Liu Dingqin

    1989-01-01

    An economic analysis code used for PWR fuel cycle is developed. This economic code includes 12 subroutines representing vavious processes for entire PWR fuel cycle, and indicates the influence of the fuel cost on the cost of the electricity generation and the influence of individual process on the sensitivity of the fuel cycle cost

  4. Evaluation of practicality of ASME code, Section XI

    International Nuclear Information System (INIS)

    Mattu, R.K.; Lauderdale, J.R.; Liu, S.N.; Lance, J.J.

    2004-01-01

    Many nuclear power plants have found that it is impractical or unduly burdensome to comply with some ASME Boiler and Pressure Code provisions and have sought relief from those provisions from the Nuclear Regulatory Commission. An Electric Power Research Institute (EPRI) project is evaluating such Code provisions and alternatives to them that will meet the safety intent of the Code with less burden on utilities. The methodology is to extract data from an on-line data base of relief requests since 1980, analyse the data to identify burdensome provisions for which there are satisfactory alternatives, and recommend changes in the Code to the ASME. (author)

  5. A decision support model for reducing electric energy consumption in elementary school facilities

    International Nuclear Information System (INIS)

    Hong, Taehoon; Koo, Choongwan; Jeong, Kwangbok

    2012-01-01

    Highlights: ► Decision support model is developed to reduce CO 2 emission in elementary schools. ► The model can select the school to be the most effective in energy savings. ► Decision tree improved the prediction accuracy by 1.83–3.88%. ► Using the model, decision-maker can save the electric-energy consumption by 16.58%. ► The model can make the educational-facility improvement program more effective. -- Abstract: The South Korean government has been actively promoting an educational-facility improvement program as part of its energy-saving efforts. This research seeks to develop a decision support model for selecting the facility expected to be effective in generating energy savings and making the facility improvement program more effective. In this research, project characteristics and electric-energy consumption data for the year 2009 were collected from 6282 elementary schools located in seven metropolitan cities in South Korea. In this research, the following were carried out: (i) a group of educational facilities was established based on electric-energy consumption, using a decision tree; (ii) a number of similar projects were retrieved from the same group of facilities, using case-based reasoning; and (iii) the accuracy of prediction was improved, using the combination of genetic algorithms, the artificial neural network, and multiple regression analysis. The results of this research can be useful for the following purposes: (i) preliminary research on the systematic and continuous management of educational facilities’ electric-energy consumption; (ii) basic research on electric-energy consumption prediction based on the project characteristics; and (iii) practical research for selecting an optimum facility that can more effectively apply an educational-facility improvement program as a decision support model.

  6. DYMEL code for prediction of dynamic stability limits in boilers

    International Nuclear Information System (INIS)

    Deam, R.T.

    1980-01-01

    Theoretical and experimental studies of Hydrodynamic Instability in boilers were undertaken to resolve the uncertainties of the existing predictive methods at the time the first Advanced Gas Cooled Reactor (AGR) plant was commissioned. The experiments were conducted on a full scale electrical simulation of an AGR boiler and revealed inadequacies in existing methods. As a result a new computer code called DYMEL was developed based on linearisation and Fourier/Laplace Transformation of the one-dimensional boiler equations in both time and space. Beside giving good agreement with local experimental data, the DYMEL code has since shown agreement with stability data from the plant, sodium heated helical tubes, a gas heated helical tube and an electrically heated U-tube. The code is now used widely within the U.K. (author)

  7. Reducing deuterium-tritium ice roughness by electrical heating of the saturated vapor

    International Nuclear Information System (INIS)

    Mapoles, E.R.; Sater, J.D.; Monsler, E.; Pipes, J.

    1996-01-01

    High gain targets for inertial confinement fusion (ICF) contain a layer of deuterium-tritium (DT) ice which surrounds a volume of DT gas in thermal equilibrium with the solid. The roughness of the cryogenic fuel layer inside of ICF targets is one of the sources of imperfections which cause implosions to deviate from perfect one dimensional performance. Experiments at Lawrence Livermore National Laboratory have shown that applying a heat flux across the inner surface of a hydrogen layer such as that inside an ICF target reduces the intrinsic roughness of the surface. We have developed a technique to generate this heat flux by applying and electric field to the DT vapor in the center of these shells. This vapor has a small but significant conductivity due to ionization caused by beta decay of tritium in the vapor and the solid. We describe here experiments using a 1.15 GHz cavity to apply an electric field to frozen DT inside of a sapphire test cell. The cell and cavity geometry allows visual observation of the frozen layers

  8. Vehicle Codes and Standards: Overview and Gap Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blake, C.; Buttner, W.; Rivkin, C.

    2010-02-01

    This report identifies gaps in vehicle codes and standards and recommends ways to fill the gaps, focusing on six alternative fuels: biodiesel, natural gas, electricity, ethanol, hydrogen, and propane.

  9. Materials and electricity

    International Nuclear Information System (INIS)

    Jaffee, R.I.

    1986-01-01

    Despite an increase in the intensity of electricity usage, electricity has been reversing its historical trend of reduced cost since 1970 to the point where costs are increasing faster than inflation. Designers and operators on both sides of the meter and the developers of materials from which the electric system is constructed must contribute to the lowering of costs and an increase in reliability for the generation, transmission and distribution, and utilization of electricity. Four specific cases illustrate the role of materials/process improvements to this end. The examples highlight the use of forged or welded integral rotors, improvements in the heat rate of coal-fired plants through higher steam conditions and reduced heat losses, reduced losses through amorphous steel cores for transformers, and reduced ac electric motor losses through silicon variable speed drives. 37 references, 27 figures, 9 tables

  10. High-Surface-Area Nitrogen-Doped Reduced Graphene Oxide for Electric Double-Layer Capacitors.

    Science.gov (United States)

    Youn, Hee-Chang; Bak, Seong-Min; Kim, Myeong-Seong; Jaye, Cherno; Fischer, Daniel A; Lee, Chang-Wook; Yang, Xiao-Qing; Roh, Kwang Chul; Kim, Kwang-Bum

    2015-06-08

    A two-step method consisting of solid-state microwave irradiation and heat treatment under NH3 gas was used to prepare nitrogen-doped reduced graphene oxide (N-RGO) with a high specific surface area (1007 m(2)  g(-1) ), high electrical conductivity (1532 S m(-1) ), and low oxygen content (1.5 wt %) for electrical double-layer capacitor applications. The specific capacitance of N-RGO was 291 F g(-1) at a current density of 1 A g(-1) , and a capacitance of 261 F g(-1) was retained at 50 A g(-1) , which indicated a very good rate capability. N-RGO also showed excellent cycling stability and preserved 96 % of the initial specific capacitance after 100 000 cycles. Near-edge X-ray absorption fine-structure spectroscopy results provided evidenced for the recovery of π conjugation in the carbon networks with the removal of oxygenated groups and revealed chemical bonding of the nitrogen atoms in N-RGO. The good electrochemical performance of N-RGO is attributed to its high surface area, high electrical conductivity, and low oxygen content. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Energy and exergy analysis of electricity generation from natural gas pressure reducing stations

    International Nuclear Information System (INIS)

    Neseli, Mehmet Alparslan; Ozgener, Onder; Ozgener, Leyla

    2015-01-01

    Highlights: • Forecasting the recoverable energy from natural gas pressure reduction stations. • Electricity generation through pressure reduction stations via turboexpanders. • A thermodynamics analysis of PRS. - Abstract: Electricity generation or power recovery through pressure reduction stations (PRS) for general use has not been realized in Izmir. The main objective of the present study was to do a case study for calculating electricity to be recovered in one natural gas pressure reduction stations in Izmir. It is the first forecasting study to obtain energy from natural gas pressure-reducing stations in Izmir. Energy can be obtained from natural gas PRS with turbo-expanders instead of using throttle valves or regulators from the PRS. The exergy performance of PRS with TE is evaluated in this study. Exergetic efficiencies of the system and components are determined to assess their individual performances. Based upon pressure change and volumetric flow rate, it can be obtained by recovering average estimated installed capacity and annual energy 494.24 kW, 4113.03 MW h, respectively. In terms of estimated installed capacity power and annual energy, the highest level is 764.88 kW, approximately 6365.34 MW h, in Aliaga PRS. Also it can be seen that CO 2 emission factor average value is 295.45 kg/MW h

  12. Development of the CRIPTE Code for Electromagnetic Coupling

    National Research Council Canada - National Science Library

    Parmantier, Jean-Philippe

    2005-01-01

    .... This code was originally developed as part of an experiment performed under the joint US-France international data exchange program on the atmospheric electricity/aircraft interactions, DEA-AF-79-7336...

  13. Investigating the burning characteristics of electric cables used in the nuclear power plant by way of 3-D transient FDS code

    Energy Technology Data Exchange (ETDEWEB)

    Ferng, Y.M., E-mail: ymferng@ess.nthu.edu.t [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, C.H. [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-01-15

    Burning characteristics of electrical cables are one of the key parameters for the fire hazard assessment of nuclear power plants (NPPs) since the cables are the essential sources of fire in the plants. A three-dimensional (3-D) transient computational fluid dynamics (CFD) code{sub F}DS is adopted in this paper to simulate these characteristics related to the cable burning. Being one of the NRC licensing fire codes, the FDS includes the thermal-hydraulic equations, the turbulence model and the chemical combustion model, etc. In order to assess the CFD fire models used in this code, a burning test using the control cable with the outer jacket of polyvinylchloride (PVC) and the inner insulation of cross-linked polyethylene (XLPE) is conducted. The measured parameters associated with the burning characteristics include the heat release rate (HRR), O{sub 2} depletion, and CO and CO{sub 2} production, etc. Except the amount of O{sub 2} consumption, the predicted transient behaviors of other parameters can reproduce the measured data. Based on the chemical combustion model in the FDS code, this discrepancy may be essentially resulted from the default value of hydrogen fraction (H{sub frac}) contained in the soot since the soot yield for the burning of PVC material is high enough that the uncertainty in the H{sub frac} value has a prominent effect on the amount of O{sub 2} consumption. This explanation can be confirmed by a benchmark calculation for simulating a burning test with the polymethylmethacrylate (PMMA) fuel of low-soot yield. The present simulation works can provide the useful information for the plant staff or the researcher as they would perform the fire hazard analysis in the NPPs using the FDS code.

  14. Permanent magnetic field, direct electric field, and infrared to reduce blood glucose level and hepatic function in mus musculus with diabetic mellitus

    Science.gov (United States)

    Suhariningsih; Basuki Notobroto, Hari; Winarni, Dwi; Achmad Hussein, Saikhu; Anggono Prijo, Tri

    2017-05-01

    Blood contains several electrolytes with positive (cation) and negative (anion) ion load. Both electrolytes deliver impulse synergistically adjusting body needs. Those electrolytes give specific effect to external disturbance such as electric, magnetic, even infrared field. A study has been conducted to reduce blood glucose level and liver function, in type 2 Diabetes Mellitus patients, using Biophysics concept which uses combination therapy of permanent magnetic field, electric field, and infrared. This study used 48 healthy mice (mus musculus), male, age 3-4 weeks, with approximately 25-30 g in weight. Mice was fed with lard as high fat diet orally, before Streptozotocin (STZ) induction become diabetic mice. Therapy was conducted by putting mice in a chamber that emits the combination of permanent magnetic field, electric field, and infrared, every day for 1 hour for 28 days. There were 4 combinations of therapy/treatment, namely: (1) permanent magnetic field, direct electric field, and infrared; (2) permanent magnetic field, direct electric field, without infrared; (3) permanent magnetic field, alternating electric field, and infrared; and (4) permanent magnetic field, alternating electric field, without infrared. The results of therapy show that every combination is able to reduce blood glucose level, AST, and ALT. However, the best result is by using combination of permanent magnetic field, direct electric field, and infrared.

  15. A 2D forward and inverse code for streaming potential problems

    Science.gov (United States)

    Soueid Ahmed, A.; Jardani, A.; Revil, A.

    2013-12-01

    The self-potential method corresponds to the passive measurement of the electrical field in response to the occurrence of natural sources of current in the ground. One of these sources corresponds to the streaming current associated with the flow of the groundwater. We can therefore apply the self- potential method to recover non-intrusively some information regarding the groundwater flow. We first solve the forward problem starting with the solution of the groundwater flow problem, then computing the source current density, and finally solving a Poisson equation for the electrical potential. We use the finite-element method to solve the relevant partial differential equations. In order to reduce the number of (petrophysical) model parameters required to solve the forward problem, we introduced an effective charge density tensor of the pore water, which can be determined directly from the permeability tensor for neutral pore waters. The second aspect of our work concerns the inversion of the self-potential data using Tikhonov regularization with smoothness and weighting depth constraints. This approach accounts for the distribution of the electrical resistivity, which can be independently and approximately determined from electrical resistivity tomography. A numerical code, SP2DINV, has been implemented in Matlab to perform both the forward and inverse modeling. Three synthetic case studies are discussed.

  16. Pricing electricity for sustainability : climate change and Canada's electricity sector

    International Nuclear Information System (INIS)

    2010-01-01

    The electricity sector is Canada's largest single source of greenhouse gas (GHG) emissions. This paper discussed electricity and carbon pricing approaches to reducing GHG emissions in the electricity sector. An overview of the links between electricity pricing and climate change was presented, and current and emerging trends in electricity pricing related to encouraging energy conservation were reviewed. Market prices and failures were discussed. Approaches to pricing electricity included an increase in block prices; time-of-use prices; demand-side management and energy efficiency; and carbon pricing in Canada and electricity pricing signals. The study showed that several provincial utilities in Canada are experimenting with market-based pricing approaches for electricity and carbon that may help to reduce GHG emissions over time. Concerns over electricity supply and the negative environmental impacts of electricity production may lead to the full social pricing of electricity in some regions of Canada. 46 refs., 3 tabs., 5 figs.

  17. Speech coding

    Energy Technology Data Exchange (ETDEWEB)

    Ravishankar, C., Hughes Network Systems, Germantown, MD

    1998-05-08

    coding techniques are equally applicable to any voice signal whether or not it carries any intelligible information, as the term speech implies. Other terms that are commonly used are speech compression and voice compression since the fundamental idea behind speech coding is to reduce (compress) the transmission rate (or equivalently the bandwidth) And/or reduce storage requirements In this document the terms speech and voice shall be used interchangeably.

  18. Interleaved Product LDPC Codes

    OpenAIRE

    Baldi, Marco; Cancellieri, Giovanni; Chiaraluce, Franco

    2011-01-01

    Product LDPC codes take advantage of LDPC decoding algorithms and the high minimum distance of product codes. We propose to add suitable interleavers to improve the waterfall performance of LDPC decoding. Interleaving also reduces the number of low weight codewords, that gives a further advantage in the error floor region.

  19. Decoding Algorithms for Random Linear Network Codes

    DEFF Research Database (Denmark)

    Heide, Janus; Pedersen, Morten Videbæk; Fitzek, Frank

    2011-01-01

    We consider the problem of efficient decoding of a random linear code over a finite field. In particular we are interested in the case where the code is random, relatively sparse, and use the binary finite field as an example. The goal is to decode the data using fewer operations to potentially...... achieve a high coding throughput, and reduce energy consumption.We use an on-the-fly version of the Gauss-Jordan algorithm as a baseline, and provide several simple improvements to reduce the number of operations needed to perform decoding. Our tests show that the improvements can reduce the number...

  20. Altered long non-coding RNA expression profile in rabbit atria with atrial fibrillation: TCONS_00075467 modulates atrial electrical remodeling by sponging miR-328 to regulate CACNA1C.

    Science.gov (United States)

    Li, Zhan; Wang, Ximin; Wang, Weizong; Du, Juanjuan; Wei, Jinqiu; Zhang, Yong; Wang, Jiangrong; Hou, Yinglong

    2017-07-01

    Electrical remodeling has been reported to play a major role in the initiation and maintenance of atrial fibrillation (AF). Long non-coding RNAs (lncRNAs) have been increasingly recognized as contributors to the pathology of heart diseases. However, the roles and mechanisms of lncRNAs in electrical remodeling during AF remain unknown. In this study, the lncRNA expression profiles of right atria were investigated in AF and non-AF rabbit models by using RNA sequencing technique and validated using quantitative real-time polymerase chain reaction (qRT-PCR). A total of 99,843 putative new lncRNAs were identified, in which 1220 differentially expressed transcripts exhibited >2-fold change. Bioinformatics analysis was conducted to predict the functions and interactions of the aberrantly expressed genes. On the basis of a series of filtering pipelines, one lncRNA, TCONS_00075467, was selected to explore its effects and mechanisms on electrical remodeling. The atrial effective refractory period was shortened in vivo and the L-type calcium current and action potential duration were decreased in vitro by silencing of TCONS_00075467 with lentiviruses. Besides, the expression of miRNA-328 was negatively correlated with TCONS_00075467. We further demonstrated that TCONS_00075467 could sponge miRNA-328 in vitro and in vivo to regulate the downstream protein coding gene CACNA1C. In addition, miRNA-328 could partly reverse the effects of TCONS_00075467 on electrical remodeling. In summary, dysregulated lncRNAs may play important roles in modulating electrical remodeling during AF. Our study may facilitate the mechanism studies of lncRNAs in AF pathogenesis and provide potential therapeutic targets for AF. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High-fidelity plasma codes for burn physics

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Graziani, Frank [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marinak, Marty [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Murillo, Michael [Michigan State Univ., East Lansing, MI (United States)

    2016-10-19

    Accurate predictions of equation of state (EOS), ionic and electronic transport properties are of critical importance for high-energy-density plasma science. Transport coefficients inform radiation-hydrodynamic codes and impact diagnostic interpretation, which in turn impacts our understanding of the development of instabilities, the overall energy balance of burning plasmas, and the efficacy of self-heating from charged-particle stopping. Important processes include thermal and electrical conduction, electron-ion coupling, inter-diffusion, ion viscosity, and charged particle stopping. However, uncertainties in these coefficients are not well established. Fundamental plasma science codes, also called high-fidelity plasma codes, are a relatively recent computational tool that augments both experimental data and theoretical foundations of transport coefficients. This paper addresses the current status of HFPC codes and their future development, and the potential impact they play in improving the predictive capability of the multi-physics hydrodynamic codes used in HED design.

  2. High Performance Electrical Modeling and Simulation Verification Test Suite - Tier I; TOPICAL

    International Nuclear Information System (INIS)

    SCHELLS, REGINA L.; BOGDAN, CAROLYN W.; WIX, STEVEN D.

    2001-01-01

    This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases

  3. Reducing BER of spectral-amplitude coding optical code-division multiple-access systems by single photodiode detection technique

    Science.gov (United States)

    Al-Khafaji, H. M. R.; Aljunid, S. A.; Amphawan, A.; Fadhil, H. A.; Safar, A. M.

    2013-03-01

    In this paper, we present a single photodiode detection (SPD) technique for spectral-amplitude coding optical code-division multiple-access (SAC-OCDMA) systems. The proposed technique eliminates both phase-induced intensity noise (PIIN) and multiple-access interference (MAI) in the optical domain. Analytical results show that for 35 simultaneous users transmitting at data rate of 622 Mbps, the bit-error rate (BER) = 1.4x10^-28 for SPD technique is much better compared to 9.3x10^-6 and 9.6x10^-3 for the modified-AND as well as the AND detection techniques, respectively. Moreover, we verified the improved performance afforded by the proposed technique using data transmission simulations.

  4. Multiple application coded switch development report

    International Nuclear Information System (INIS)

    Bernal, E.L.; Kestly, J.D.

    1979-03-01

    The development of the Multiple Application Coded Switch (MACS) and its related controller are documented; the functional and electrical characteristics are described; the interface requirements defined, and a troubleshooting guide provided. The system was designed for the Safe Secure Trailer System used for secure transportation of nuclear material

  5. Securing optical code-division multiple-access networks with a postswitching coding scheme of signature reconfiguration

    Science.gov (United States)

    Huang, Jen-Fa; Meng, Sheng-Hui; Lin, Ying-Chen

    2014-11-01

    The optical code-division multiple-access (OCDMA) technique is considered a good candidate for providing optical layer security. An enhanced OCDMA network security mechanism with a pseudonoise (PN) random digital signals type of maximal-length sequence (M-sequence) code switching to protect against eavesdropping is presented. Signature codes unique to individual OCDMA-network users are reconfigured according to the register state of the controlling electrical shift registers. Examples of signature reconfiguration following state switching of the controlling shift register for both the network user and the eavesdropper are numerically illustrated. Dynamically changing the PN state of the shift register to reconfigure the user signature sequence is shown; this hinders eavesdroppers' efforts to decode correct data sequences. The proposed scheme increases the probability of eavesdroppers committing errors in decoding and thereby substantially enhances the degree of an OCDMA network's confidentiality.

  6. Spike Code Flow in Cultured Neuronal Networks.

    Science.gov (United States)

    Tamura, Shinichi; Nishitani, Yoshi; Hosokawa, Chie; Miyoshi, Tomomitsu; Sawai, Hajime; Kamimura, Takuya; Yagi, Yasushi; Mizuno-Matsumoto, Yuko; Chen, Yen-Wei

    2016-01-01

    We observed spike trains produced by one-shot electrical stimulation with 8 × 8 multielectrodes in cultured neuronal networks. Each electrode accepted spikes from several neurons. We extracted the short codes from spike trains and obtained a code spectrum with a nominal time accuracy of 1%. We then constructed code flow maps as movies of the electrode array to observe the code flow of "1101" and "1011," which are typical pseudorandom sequence such as that we often encountered in a literature and our experiments. They seemed to flow from one electrode to the neighboring one and maintained their shape to some extent. To quantify the flow, we calculated the "maximum cross-correlations" among neighboring electrodes, to find the direction of maximum flow of the codes with lengths less than 8. Normalized maximum cross-correlations were almost constant irrespective of code. Furthermore, if the spike trains were shuffled in interval orders or in electrodes, they became significantly small. Thus, the analysis suggested that local codes of approximately constant shape propagated and conveyed information across the network. Hence, the codes can serve as visible and trackable marks of propagating spike waves as well as evaluating information flow in the neuronal network.

  7. A 10 Gbit/s OCDMA system based on electric encoding and optical transmission

    Science.gov (United States)

    Li, Chuan-qi; Hu, Jin-lin; He, Dong-dong; Chen, Mei-juan; Wang, Da-chi; Chen, Yan

    2013-11-01

    An electric encoded/optical transmission system of code division multiple access (CDMA) is proposed. It encodes the user signal in electric domain, and transfers the different code slice signals via the different wavelengths of light. This electric domain encoder/decoder is compared with current traditional encoder/decoder. Four-user modulation/demodulation optical CDMA (OCDMA) system with rate of 2.5 Gbit/s is simulated, which is based on the optical orthogonal code (OCC) designed in our laboratory. The results show that the structure of electric encoding/optical transmission can encode/decode signal correctly, and can achieve the chip rate equal to the user data rate. It can overcome the rate limitation of electronic bottleneck, and bring some potential applications in the electro-optical OCDMA system.

  8. Permanent magnetic field, direct electric field, and infrared to reduce blood glucose level and hepatic function in mus musculus with diabetic mellitus

    International Nuclear Information System (INIS)

    Suhariningsih; Prijo, Tri Anggono; Notobroto, Hari Basuki; Winarni, Dwi; Hussein, Saikhu Achmad

    2017-01-01

    Blood contains several electrolytes with positive (cation) and negative (anion) ion load. Both electrolytes deliver impulse synergistically adjusting body needs. Those electrolytes give specific effect to external disturbance such as electric, magnetic, even infrared field. A study has been conducted to reduce blood glucose level and liver function, in type 2 Diabetes Mellitus patients, using Biophysics concept which uses combination therapy of permanent magnetic field, electric field, and infrared. This study used 48 healthy mice ( mus musculus ), male, age 3-4 weeks, with approximately 25-30 g in weight. Mice was fed with lard as high fat diet orally, before Streptozotocin (STZ) induction become diabetic mice. Therapy was conducted by putting mice in a chamber that emits the combination of permanent magnetic field, electric field, and infrared, every day for 1 hour for 28 days. There were 4 combinations of therapy/treatment, namely: (1) permanent magnetic field, direct electric field, and infrared; (2) permanent magnetic field, direct electric field, without infrared; (3) permanent magnetic field, alternating electric field, and infrared; and (4) permanent magnetic field, alternating electric field, without infrared. The results of therapy show that every combination is able to reduce blood glucose level, AST, and ALT. However, the best result is by using combination of permanent magnetic field, direct electric field, and infrared. (paper)

  9. ComboCoding: Combined intra-/inter-flow network coding for TCP over disruptive MANETs

    Directory of Open Access Journals (Sweden)

    Chien-Chia Chen

    2011-07-01

    Full Text Available TCP over wireless networks is challenging due to random losses and ACK interference. Although network coding schemes have been proposed to improve TCP robustness against extreme random losses, a critical problem still remains of DATA–ACK interference. To address this issue, we use inter-flow coding between DATA and ACK to reduce the number of transmissions among nodes. In addition, we also utilize a “pipeline” random linear coding scheme with adaptive redundancy to overcome high packet loss over unreliable links. The resulting coding scheme, ComboCoding, combines intra-flow and inter-flow coding to provide robust TCP transmission in disruptive wireless networks. The main contributions of our scheme are twofold; the efficient combination of random linear coding and XOR coding on bi-directional streams (DATA and ACK, and the novel redundancy control scheme that adapts to time-varying and space-varying link loss. The adaptive ComboCoding was tested on a variable hop string topology with unstable links and on a multipath MANET with dynamic topology. Simulation results show that TCP with ComboCoding delivers higher throughput than with other coding options in high loss and mobile scenarios, while introducing minimal overhead in normal operation.

  10. Effect of AC electric fields on flame spread over electrical wire

    KAUST Repository

    Kim, Minkuk

    2011-01-01

    The effect of electric fields on the characteristics of flame spread over insulated electrical wire has been investigated experimentally by varying AC voltage and frequency applied to the wire in the normal gravity condition. The polyethylene (PE) insulated electrical wire was placed horizontally on electrically non-conducting posts and one end of the wire was connected to the high voltage terminal. Thus, the electrical system is the single electrode configuration. The wire was ignited at one end and the flame spread rate along the wire has been measured from the images using a video camera. Two distinct regimes existed depending on the applied AC frequency. In the low frequency regime, the flame spread rate decreased with the frequency and voltage. While in the high frequency regime, it decreased initially with voltage and then increased. At high frequency, the spread rate was even over that without applying electric fields. This result implies that fire safety codes developed without considering the effect of electric fields may require modifications. © 2010 Published by Elsevier Inc. on behalf of The Combustion Institute. All rights reserved.

  11. Performance Analysis of CRC Codes for Systematic and Nonsystematic Polar Codes with List Decoding

    Directory of Open Access Journals (Sweden)

    Takumi Murata

    2018-01-01

    Full Text Available Successive cancellation list (SCL decoding of polar codes is an effective approach that can significantly outperform the original successive cancellation (SC decoding, provided that proper cyclic redundancy-check (CRC codes are employed at the stage of candidate selection. Previous studies on CRC-assisted polar codes mostly focus on improvement of the decoding algorithms as well as their implementation, and little attention has been paid to the CRC code structure itself. For the CRC-concatenated polar codes with CRC code as their outer code, the use of longer CRC code leads to reduction of information rate, whereas the use of shorter CRC code may reduce the error detection probability, thus degrading the frame error rate (FER performance. Therefore, CRC codes of proper length should be employed in order to optimize the FER performance for a given signal-to-noise ratio (SNR per information bit. In this paper, we investigate the effect of CRC codes on the FER performance of polar codes with list decoding in terms of the CRC code length as well as its generator polynomials. Both the original nonsystematic and systematic polar codes are considered, and we also demonstrate that different behaviors of CRC codes should be observed depending on whether the inner polar code is systematic or not.

  12. State-of-the-art of wind turbine design codes: main features overview for cost-effective generation

    Energy Technology Data Exchange (ETDEWEB)

    Molenaar, D-P.; Dijkstra, S. [Delft University of Technology (Netherlands). Mechanical Engineering Systems and Control Group

    1999-07-01

    For successful large-scale application of wind energy, the price of electricity generated by wind turbines should decrease. Model-based control can be important since it has the potential to reduce fatigue loads, while simultaneously maintaining a desired amount of energy production. The controller synthesis, however, requires a mathematical model describing the most important dynamics of the complete wind turbine. In the wind energy community there is a wide variety in codes used to model a wind turbine's dynamic behaviour or to carry out design calculations. In this paper, the main features of the state-of-the-art wind turbine design codes have been investigated in order to judge the appropriateness of using one of these for the modeling, identification and control of flexible, variable speed wind turbines. It can be concluded that, although the sophistication of the design codes has increased enormously over the last two decades, they are, in general, not suitable for the design, and easy implementation of optimal operating strategies.

  13. Information-Measuring System to Control the Electrical and Mechanical Motor Parameters

    Directory of Open Access Journals (Sweden)

    K. S. Ermakov

    2015-01-01

    Full Text Available The article considers the issue of creating an information-measuring system for an asynchronous motor. The presented system allows ensuring the failure-free protection of electromotor, considerably reducing costs of its unplanned repair, and reduced economical loss from idle time of the electric motor.The developed system comprises a mathematical model and two subsystems to measure electrical and mechanical parameters of the asynchronous motor.The electrical subsystem comprises a FLUKE company recording multi-meter a signal from which passes through the block of intervals and coding and comes to PC.The mechanical subsystem uses technical tools of phase-chronometric method. This method developed at the department of Metrology and Interchangeability allows an increasing efficiency of developed informative-measuring system. Mathematical modeling is used to link information from subsystems (electrical and mechanical to electromotor construction.The work conducted mathematical modeling of some defects of electric motor, namely: rupture of rotor winding and line surge.The mathematical model in Mathcad was based on a modified formula of Kloss. It allows us to tie the average current value of the torque of the induction motor with shaft speed and take into account the effect of the frequency and voltage.The Matlab Simulink (the package for visual programming environment was used to simulate a rupture of the rotor winding. Simulation results showed how the phase currents of the electric motor changed with the winding rupture.The developed information-measuring system has a number of advantages over traditional systems used in this field (vibration-based diagnostics systems. It will allow an increasing efficiency of the system for diagnostics of electrical machines created on the basis of this information-measuring system.

  14. The electric vehicles as a mean to reduce CO2 emissions and energy costs in isolated regions. The São Miguel (Azores) case study

    International Nuclear Information System (INIS)

    Camus, Cristina; Farias, Tiago

    2012-01-01

    Most of small islands around the world today, are dependent on imported fossil fuels for the majority of their energy needs especially for transport activities and electricity production. The use of locally renewable energy resources and the implementation of energy efficiency measures could make a significant contribution to their economic development by reducing fossil fuel imports. An electrification of vehicles has been suggested as a way to both reduce pollutant emissions and increase security of supply of the transportation sector by reducing the dependence on oil products imports and facilitate the accommodation of renewable electricity generation, such as wind and, in the case of volcanic islands like São Miguel (Azores) of the geothermal energy whose penetration has been limited by the valley electricity consumption level. In this research, three scenarios of EV penetration were studied and it was verified that, for a 15% LD fleet replacement by EVs with 90% of all energy needs occurring during the night, the accommodation of 10 MW of new geothermal capacity becomes viable. Under this scenario, reductions of 8% in electricity costs, 14% in energy, 23% in fossil fuels use and CO 2 emissions for the transportation and electricity production sectors could be expected. - Highlights: ► EVs impacts on the electric system in energy and power profiles, costs and emissions. ► At least an EV penetration of 15% is needed to allow new geothermal power production. ► Reductions in energy, fossil fuels use and CO 2 emissions of 9%, 16% and 17% respectively. ► Electricity production with more % of renewable technologies reduces unit costs.

  15. Plasma burn-through simulations using the DYON code and predictions for ITER

    International Nuclear Information System (INIS)

    Kim, Hyun-Tae; Sips, A C C; De Vries, P C

    2013-01-01

    This paper will discuss simulations of the full ionization process (i.e. plasma burn-through), fundamental to creating high temperature plasma. By means of an applied electric field, the gas is partially ionized by the electron avalanche process. In order for the electron temperature to increase, the remaining neutrals need to be fully ionized in the plasma burn-through phase, as radiation is the main contribution to the electron power loss. The radiated power loss can be significantly affected by impurities resulting from interaction with the plasma facing components. The DYON code is a plasma burn-through simulator developed at Joint European Torus (JET) (Kim et al and EFDA-JET Contributors 2012 Nucl. Fusion 52 103016, Kim, Sips and EFDA-JET Contributors 2013 Nucl. Fusion 53 083024). The dynamic evolution of the plasma temperature and plasma densities including the impurity content is calculated in a self-consistent way using plasma wall interaction models. The recent installation of a beryllium wall at JET enabled validation of the plasma burn-through model in the presence of new, metallic plasma facing components. The simulation results of the plasma burn-through phase show a consistent good agreement against experiments at JET, and explain differences observed during plasma initiation with the old carbon plasma facing components. In the International Thermonuclear Experimental Reactor (ITER), the allowable toroidal electric field is restricted to 0.35 (V m −1 ), which is significantly lower compared to the typical value (∼1 (V m −1 )) used in the present devices. The limitation on toroidal electric field also reduces the range of other operation parameters during plasma formation in ITER. Thus, predictive simulations of plasma burn-through in ITER using validated model is of crucial importance. This paper provides an overview of the DYON code and the validation, together with new predictive simulations for ITER using the DYON code. (paper)

  16. Transplantation and application of RADTRAN 4.0 Code in China

    International Nuclear Information System (INIS)

    Wang Jiaming; Li Jikai; Li Shouping; Qian Zhong

    1994-01-01

    The authors present the work of transplanting RADTRAN 4.0 Code from a DEC VAX System to a MICRO VAX-II/VMS System and LX-386 SX PC in the Institute. Through repeated tests, running example cases and analyzing calculation results, it has been proved that the transplantation of the RADTRAN 4.0 Code is successful. The transplanted RADTRAN 4.0 has been taken in nuclear electricity software product library. At present, several institutions in China has started to use the Code

  17. Code portability and data management considerations in the SAS3D LMFBR accident-analysis code

    International Nuclear Information System (INIS)

    Dunn, F.E.

    1981-01-01

    The SAS3D code was produced from a predecessor in order to reduce or eliminate interrelated problems in the areas of code portability, the large size of the code, inflexibility in the use of memory and the size of cases that can be run, code maintenance, and running speed. Many conventional solutions, such as variable dimensioning, disk storage, virtual memory, and existing code-maintenance utilities were not feasible or did not help in this case. A new data management scheme was developed, coding standards and procedures were adopted, special machine-dependent routines were written, and a portable source code processing code was written. The resulting code is quite portable, quite flexible in the use of memory and the size of cases that can be run, much easier to maintain, and faster running. SAS3D is still a large, long running code that only runs well if sufficient main memory is available

  18. MAGNETOHYDRODYNAMIC EQUATIONS (MHD GENERATION CODE

    Directory of Open Access Journals (Sweden)

    Francisco Frutos Alfaro

    2017-04-01

    Full Text Available A program to generate codes in Fortran and C of the full magnetohydrodynamic equations is shown. The program uses the free computer algebra system software REDUCE. This software has a package called EXCALC, which is an exterior calculus program. The advantage of this program is that it can be modified to include another complex metric or spacetime. The output of this program is modified by means of a LINUX script which creates a new REDUCE program to manipulate the magnetohydrodynamic equations to obtain a code that can be used as a seed for a magnetohydrodynamic code for numerical applications. As an example, we present part of the output of our programs for Cartesian coordinates and how to do the discretization.

  19. Governance codes: facts or fictions? a study of governance codes in colombia1,2

    Directory of Open Access Journals (Sweden)

    Julián Benavides Franco

    2010-10-01

    Full Text Available This article studies the effects on accounting performance and financing decisions of Colombian firms after issuing a corporate governance code. We assemble a database of Colombian issuers and test the hypotheses of improved performance and higher leverage after issuing a code. The results show that the firms’ return on assets after the code introduction improves in excess of 1%; the effect is amplified by the code quality. Additionally, the firms leverage increased, in excess of 5%, when the code quality was factored into the analysis. These results suggest that controlling parties commitment to self restrain, by reducing their private benefits and/or the expropriation of non controlling parties, through the code introduction, is indeed an effective measure and that the financial markets agree, increasing the supply of funds to the firms.

  20. Utility experience in code updating of equipment built to 1974 code, Section 3, Subsection NF

    International Nuclear Information System (INIS)

    Rao, K.R.; Deshpande, N.

    1990-01-01

    This paper addresses changes to ASME Code Subsection NF and reconciles the differences between the updated codes and the as built construction code, of ASME Section III, 1974 to which several nuclear plants have been built. Since Section III is revised every three years and replacement parts complying with the construction code are invariably not available from the plant stock inventory, parts must be procured from vendors who comply with the requirements of the latest codes. Aspects of the ASME code which reflect Subsection NF are identified and compared with the later Code editions and addenda, especially up to and including the 1974 ASME code used as the basis for the plant qualification. The concern of the regulatory agencies is that if later code allowables and provisions are adopted it is possible to reduce the safety margins of the construction code. Areas of concern are highlighted and the specific changes of later codes are discerned; adoption of which, would not sacrifice the intended safety margins of the codes to which plants are licensed

  1. The role of advanced nuclear plants in reducing the environmental and economic impact of greenhouse emissions on electrical generation

    International Nuclear Information System (INIS)

    Redding, J.; Veitch, C.

    1995-01-01

    The paper discusses the potential impact of imposing economic penalties (externalities) in an effort to reduce emission levels and environmental effect of existing and newly constructed electric facilities, on the selection of generation technology and fuel type, and how the nuclear industry's efforts to develop the next generation of nuclear power facilities will provide an economic, low emission generating option to meet the expanding global electrical needs. The efforts of the US nuclear industry to improve the performance and economics of the existing and next generation facilities are presented, focusing on General Electric's Advanced Boiling Water Reactor and Simplified Boiling Water Reactor. 5 refs., 4 figs., 2 tabs

  2. ITS Version 6 : the integrated TIGER series of coupled electron/photon Monte Carlo transport codes.

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Brian Claude; Kensek, Ronald Patrick; Laub, Thomas William

    2008-04-01

    ITS is a powerful and user-friendly software package permitting state-of-the-art Monte Carlo solution of lineartime-independent coupled electron/photon radiation transport problems, with or without the presence of macroscopic electric and magnetic fields of arbitrary spatial dependence. Our goal has been to simultaneously maximize operational simplicity and physical accuracy. Through a set of preprocessor directives, the user selects one of the many ITS codes. The ease with which the makefile system is applied combines with an input scheme based on order-independent descriptive keywords that makes maximum use of defaults and internal error checking to provide experimentalists and theorists alike with a method for the routine but rigorous solution of sophisticated radiation transport problems. Physical rigor is provided by employing accurate cross sections, sampling distributions, and physical models for describing the production and transport of the electron/photon cascade from 1.0 GeV down to 1.0 keV. The availability of source code permits the more sophisticated user to tailor the codes to specific applications and to extend the capabilities of the codes to more complex applications. Version 6, the latest version of ITS, contains (1) improvements to the ITS 5.0 codes, and (2) conversion to Fortran 90. The general user friendliness of the software has been enhanced through memory allocation to reduce the need for users to modify and recompile the code.

  3. SunShot solar power reduces costs and uncertainty in future low-carbon electricity systems.

    Science.gov (United States)

    Mileva, Ana; Nelson, James H; Johnston, Josiah; Kammen, Daniel M

    2013-08-20

    The United States Department of Energy's SunShot Initiative has set cost-reduction targets of $1/watt for central-station solar technologies. We use SWITCH, a high-resolution electricity system planning model, to study the implications of achieving these targets for technology deployment and electricity costs in western North America, focusing on scenarios limiting carbon emissions to 80% below 1990 levels by 2050. We find that achieving the SunShot target for solar photovoltaics would allow this technology to provide more than a third of electric power in the region, displacing natural gas in the medium term and reducing the need for nuclear and carbon capture and sequestration (CCS) technologies, which face technological and cost uncertainties, by 2050. We demonstrate that a diverse portfolio of technological options can help integrate high levels of solar generation successfully and cost-effectively. The deployment of GW-scale storage plays a central role in facilitating solar deployment and the availability of flexible loads could increase the solar penetration level further. In the scenarios investigated, achieving the SunShot target can substantially mitigate the cost of implementing a carbon cap, decreasing power costs by up to 14% and saving up to $20 billion ($2010) annually by 2050 relative to scenarios with Reference solar costs.

  4. PV installations, protection and the code

    Energy Technology Data Exchange (ETDEWEB)

    Silecky, L. [Mersen, Toronto, ON (Canada)

    2010-12-15

    This article discussed the need for improved standards in Ontario's solar industry to ensure safety for the systems and also safety for the workers. Photovoltaic cells used in solar arrays can now deliver between 50 vDC to 600 vDC. The workings of such a high voltage photocell must be understood in order to understand its protection needs. Since PVs are semiconductors and susceptible to damage from short circuits and overloads, a fast-acting overcurrent protective device (OCPD) should be used. Combiner boxes are also needed to provide a clean method of safely connecting all the wires that are needed in the system, including surge protection and a means of isolation between the PV array and the inverter. Section 50 of the Canadian Electrical Code outlines the requirements for solar PV systems, but it does not mention the protection of DC circuits, including DC fuse protectors which are manufactured to provide a high degree of protection for the PV array. As the photovoltaic (PV) market continues to grow in Ontario, the PV industry also has a responsibility to ensure it is in compliance with codes and standards related to photovoltaic systems. This author suggested that Article 690 of the National Electric Code (NEC) is a good document to use when determining the requirements for PV systems. 3 figs.

  5. Optimal Charging of Electric Vehicles with Trading on the Intraday Electricity Market

    Directory of Open Access Journals (Sweden)

    Ilham Naharudinsyah

    2018-06-01

    Full Text Available Trading on the energy market is a possible way to reduce the electricity costs of charging electric vehicles at public charging stations. In many European countries, it is possible to trade electricity until shortly before the period of delivery on so called intraday electricity markets. In the present work, the potential for reducing the electricity costs by trading on the intraday market is investigated using the example of the German market. Based on simulations, the authors reveal that by optimizing the charging schedule together with the trading on the intraday electricity market, the costs can be reduced by around 8% compared to purchasing all the required energy from the energy supplier. By allowing the charging station operator to resell the energy to the intraday electricity market, an additional cost reduction of around 1% can be achieved. Besides the potential cost savings, the impacts of the trading unit and of the lead time of the intraday electricity market on the costs are investigated. The authors reveal that the achievable electricity costs can be strongly affected by the lead time, while the trading unit has only a minor effect on the costs.

  6. Static electricity: A literature review

    Science.gov (United States)

    Crow, Rita M.

    1991-11-01

    The major concern with static electricity is its discharging in a flammable atmosphere which can explode and cause a fire. Textile materials can have their electrical resistivity decreased by the addition of antistatic finishes, imbedding conductive particles into the fibres or by adding metal fibers to the yarns. The test methods used in the studies of static electricity include measuring the static properties of materials, of clothed persons, and of the ignition energy of flammable gases. Surveys have shown that there is sparse evidence for fires definitively being caused by static electricity. However, the 'worst-case' philosophy has been adopted and a static electricity safety code is described, including correct grounding procedures and the wearing of anti-static clothing and footwear.

  7. Spike Code Flow in Cultured Neuronal Networks

    Directory of Open Access Journals (Sweden)

    Shinichi Tamura

    2016-01-01

    Full Text Available We observed spike trains produced by one-shot electrical stimulation with 8 × 8 multielectrodes in cultured neuronal networks. Each electrode accepted spikes from several neurons. We extracted the short codes from spike trains and obtained a code spectrum with a nominal time accuracy of 1%. We then constructed code flow maps as movies of the electrode array to observe the code flow of “1101” and “1011,” which are typical pseudorandom sequence such as that we often encountered in a literature and our experiments. They seemed to flow from one electrode to the neighboring one and maintained their shape to some extent. To quantify the flow, we calculated the “maximum cross-correlations” among neighboring electrodes, to find the direction of maximum flow of the codes with lengths less than 8. Normalized maximum cross-correlations were almost constant irrespective of code. Furthermore, if the spike trains were shuffled in interval orders or in electrodes, they became significantly small. Thus, the analysis suggested that local codes of approximately constant shape propagated and conveyed information across the network. Hence, the codes can serve as visible and trackable marks of propagating spike waves as well as evaluating information flow in the neuronal network.

  8. 3D electrical conductivity tomography of volcanoes

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.; Byrdina, S.; Coperey, A.; Gailler, L.; Grobbe, N.; Viveiros, F.; Silva, C.; Jougnot, D.; Ghorbani, A.; Hogg, C.; Kiyan, D.; Rath, V.; Heap, M. J.; Grandis, H.; Humaida, H.

    2018-05-01

    Electrical conductivity tomography is a well-established galvanometric method for imaging the subsurface electrical conductivity distribution. We characterize the conductivity distribution of a set of volcanic structures that are different in terms of activity and morphology. For that purpose, we developed a large-scale inversion code named ECT-3D aimed at handling complex topographical effects like those encountered in volcanic areas. In addition, ECT-3D offers the possibility of using as input data the two components of the electrical field recorded at independent stations. Without prior information, a Gauss-Newton method with roughness constraints is used to solve the inverse problem. The roughening operator used to impose constraints is computed on unstructured tetrahedral elements to map complex geometries. We first benchmark ECT-3D on two synthetic tests. A first test using the topography of Mt. St Helens volcano (Washington, USA) demonstrates that we can successfully reconstruct the electrical conductivity field of an edifice marked by a strong topography and strong variations in the resistivity distribution. A second case study is used to demonstrate the versatility of the code in using the two components of the electrical field recorded on independent stations along the ground surface. Then, we apply our code to real data sets recorded at (i) a thermally active area of Yellowstone caldera (Wyoming, USA), (ii) a monogenetic dome on Furnas volcano (the Azores, Portugal), and (iii) the upper portion of the caldera of Kīlauea (Hawai'i, USA). The tomographies reveal some of the major structures of these volcanoes as well as identifying alteration associated with high surface conductivities. We also review the petrophysics underlying the interpretation of the electrical conductivity of fresh and altered volcanic rocks and molten rocks to show that electrical conductivity tomography cannot be used as a stand-alone technique due to the non-uniqueness in

  9. Cut Electric Bills by Controlling Demand

    Science.gov (United States)

    Grumman, David L.

    1974-01-01

    Electric bills can be reduced by lowering electric consumption and by controlling demand -- the amount of electricity used at a certain point in time. Gives tips to help reduce electric demand at peak power periods. (Author/DN)

  10. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2012-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  11. ASME Code Efforts Supporting HTGRs

    Energy Technology Data Exchange (ETDEWEB)

    D.K. Morton

    2011-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This report discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.

  12. Comparison of High-Fidelity Computational Tools for Wing Design of a Distributed Electric Propulsion Aircraft

    Science.gov (United States)

    Deere, Karen A.; Viken, Sally A.; Carter, Melissa B.; Viken, Jeffrey K.; Derlaga, Joseph M.; Stoll, Alex M.

    2017-01-01

    A variety of tools, from fundamental to high order, have been used to better understand applications of distributed electric propulsion to aid the wing and propulsion system design of the Leading Edge Asynchronous Propulsion Technology (LEAPTech) project and the X-57 Maxwell airplane. Three high-fidelity, Navier-Stokes computational fluid dynamics codes used during the project with results presented here are FUN3D, STAR-CCM+, and OVERFLOW. These codes employ various turbulence models to predict fully turbulent and transitional flow. Results from these codes are compared for two distributed electric propulsion configurations: the wing tested at NASA Armstrong on the Hybrid-Electric Integrated Systems Testbed truck, and the wing designed for the X-57 Maxwell airplane. Results from these computational tools for the high-lift wing tested on the Hybrid-Electric Integrated Systems Testbed truck and the X-57 high-lift wing presented compare reasonably well. The goal of the X-57 wing and distributed electric propulsion system design achieving or exceeding the required ?? (sub L) = 3.95 for stall speed was confirmed with all of the computational codes.

  13. Climate change and peak demand for electricity: Evaluating policies for reducing peak demand under different climate change scenarios

    Science.gov (United States)

    Anthony, Abigail Walker

    This research focuses on the relative advantages and disadvantages of using price-based and quantity-based controls for electricity markets. It also presents a detailed analysis of one specific approach to quantity based controls: the SmartAC program implemented in Stockton, California. Finally, the research forecasts electricity demand under various climate scenarios, and estimates potential cost savings that could result from a direct quantity control program over the next 50 years in each scenario. The traditional approach to dealing with the problem of peak demand for electricity is to invest in a large stock of excess capital that is rarely used, thereby greatly increasing production costs. Because this approach has proved so expensive, there has been a focus on identifying alternative approaches for dealing with peak demand problems. This research focuses on two approaches: price based approaches, such as real time pricing, and quantity based approaches, whereby the utility directly controls at least some elements of electricity used by consumers. This research suggests that well-designed policies for reducing peak demand might include both price and quantity controls. In theory, sufficiently high peak prices occurring during periods of peak demand and/or low supply can cause the quantity of electricity demanded to decline until demand is in balance with system capacity, potentially reducing the total amount of generation capacity needed to meet demand and helping meet electricity demand at the lowest cost. However, consumers need to be well informed about real-time prices for the pricing strategy to work as well as theory suggests. While this might be an appropriate assumption for large industrial and commercial users who have potentially large economic incentives, there is not yet enough research on whether households will fully understand and respond to real-time prices. Thus, while real-time pricing can be an effective tool for addressing the peak load

  14. Current and anticipated uses of thermal-hydraulic codes in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Teschendorff, V.; Sommer, F.; Depisch, F.

    1997-07-01

    In Germany, one third of the electrical power is generated by nuclear plants. ATHLET and S-RELAP5 are successfully applied for safety analyses of the existing PWR and BWR reactors and possible future reactors, e.g. EPR. Continuous development and assessment of thermal-hydraulic codes are necessary in order to meet present and future needs of licensing organizations, utilities, and vendors. Desired improvements include thermal-hydraulic models, multi-dimensional simulation, computational speed, interfaces to coupled codes, and code architecture. Real-time capability will be essential for application in full-scope simulators. Comprehensive code validation and quantification of uncertainties are prerequisites for future best-estimate analyses.

  15. Current and anticipated uses of thermal-hydraulic codes in Germany

    International Nuclear Information System (INIS)

    Teschendorff, V.; Sommer, F.; Depisch, F.

    1997-01-01

    In Germany, one third of the electrical power is generated by nuclear plants. ATHLET and S-RELAP5 are successfully applied for safety analyses of the existing PWR and BWR reactors and possible future reactors, e.g. EPR. Continuous development and assessment of thermal-hydraulic codes are necessary in order to meet present and future needs of licensing organizations, utilities, and vendors. Desired improvements include thermal-hydraulic models, multi-dimensional simulation, computational speed, interfaces to coupled codes, and code architecture. Real-time capability will be essential for application in full-scope simulators. Comprehensive code validation and quantification of uncertainties are prerequisites for future best-estimate analyses

  16. Reducing Electricity Demand Peaks by Scheduling Home Appliances Usage

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2011-01-01

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users’ appliances...... should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power...... consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions...

  17. Computation of Thermodynamic Equilibria Pertinent to Nuclear Materials in Multi-Physics Codes

    Science.gov (United States)

    Piro, Markus Hans Alexander

    Nuclear energy plays a vital role in supporting electrical needs and fulfilling commitments to reduce greenhouse gas emissions. Research is a continuing necessity to improve the predictive capabilities of fuel behaviour in order to reduce costs and to meet increasingly stringent safety requirements by the regulator. Moreover, a renewed interest in nuclear energy has given rise to a "nuclear renaissance" and the necessity to design the next generation of reactors. In support of this goal, significant research efforts have been dedicated to the advancement of numerical modelling and computational tools in simulating various physical and chemical phenomena associated with nuclear fuel behaviour. This undertaking in effect is collecting the experience and observations of a past generation of nuclear engineers and scientists in a meaningful way for future design purposes. There is an increasing desire to integrate thermodynamic computations directly into multi-physics nuclear fuel performance and safety codes. A new equilibrium thermodynamic solver is being developed with this matter as a primary objective. This solver is intended to provide thermodynamic material properties and boundary conditions for continuum transport calculations. There are several concerns with the use of existing commercial thermodynamic codes: computational performance; limited capabilities in handling large multi-component systems of interest to the nuclear industry; convenient incorporation into other codes with quality assurance considerations; and, licensing entanglements associated with code distribution. The development of this software in this research is aimed at addressing all of these concerns. The approach taken in this work exploits fundamental principles of equilibrium thermodynamics to simplify the numerical optimization equations. In brief, the chemical potentials of all species and phases in the system are constrained by estimates of the chemical potentials of the system

  18. Near-optimal order-reduced control for A/C (air-conditioning) system of EVs (electric vehicles)

    International Nuclear Information System (INIS)

    Chiu, Chien-Chin; Tsai, Nan-Chyuan; Lin, Chun-Chi

    2014-01-01

    This work is aimed to investigate the regulation problem for thermal comfortableness and propose control strategies for cabin environment of EVs (electric vehicles) by constructing a reduced-scale A/C (air-conditioning) system which mainly consists of two modules: ECB (environmental control box) and AHU (air-handling unit). Temperature and humidity in the ECB can be regulated by AHU via cooling, heating, mixing air streams and adjusting speed of fans. To synthesize the near-optimal controllers, the mathematical model for the system thermodynamics is developed by employing the equivalent lumped heat capacity approach, energy/mass conservation principle and the heat transfer theories. In addition, from the clustering pattern of system eigenvalues, the thermodynamics of the interested system can evidently be characterized by two-time-scale property. That is, the studied system can be decoupled into two subsystems, slow mode and fast mode, by singular perturbation technique. As to the optimal control strategies for EVs, by taking thermal comfortableness, humidity and energy consumption all into account, a series of optimal controllers is synthesized on the base of the order-reduced thermodynamic model. The feedback control loop for the experimental test rig is examined and realized by the aid of the control system development kit dSPACE DS1104 and the commercial software MATLAB/Simulink. To sum up, the intensive computer simulations and experimental results verify that the performance of the near-optimal order-reduced control law is almost as superior as that of standard LQR (Linear-Quadratic Regulator). - Highlights: • A reduced-scale test rig for A/C (air-conditioning) system to imitate the temperature/humidity of cabin in EV (electric vehicle) is constructed. • The non-linear thermodynamic model of A/C system can be decoupled by singular perturbation technique. • The temperature/humidity in cabin is regulated to the desired values by proposed optimal

  19. Strategic Sustainable Electric Power Energy for Ethiopia:- Electric ...

    African Journals Online (AJOL)

    Mengesha

    Present trend in electrical engineering education; ... (EERS) USA plans to reduce its electric energy ... at the distribution center, step-down to low voltage. (400 V .... Ethiopian market and in use [13]. .... involved in the teaching EEPCo students.

  20. Neoclassical simulation of tokamak plasmas using the continuum gyrokinetic code TEMPEST.

    Science.gov (United States)

    Xu, X Q

    2008-07-01

    We present gyrokinetic neoclassical simulations of tokamak plasmas with a self-consistent electric field using a fully nonlinear (full- f ) continuum code TEMPEST in a circular geometry. A set of gyrokinetic equations are discretized on a five-dimensional computational grid in phase space. The present implementation is a method of lines approach where the phase-space derivatives are discretized with finite differences, and implicit backward differencing formulas are used to advance the system in time. The fully nonlinear Boltzmann model is used for electrons. The neoclassical electric field is obtained by solving the gyrokinetic Poisson equation with self-consistent poloidal variation. With a four-dimensional (psi,theta,micro) version of the TEMPEST code, we compute the radial particle and heat fluxes, the geodesic-acoustic mode, and the development of the neoclassical electric field, which we compare with neoclassical theory using a Lorentz collision model. The present work provides a numerical scheme for self-consistently studying important dynamical aspects of neoclassical transport and electric field in toroidal magnetic fusion devices.

  1. Residential demand response reduces air pollutant emissions on peak electricity demand days in New York City

    International Nuclear Information System (INIS)

    Gilbraith, Nathaniel; Powers, Susan E.

    2013-01-01

    Many urban areas in the United States have experienced difficulty meeting the National Ambient Air Quality Standards (NAAQS), partially due to pollution from electricity generating units. We evaluated the potential for residential demand response to reduce pollutant emissions on days with above average pollutant emissions and a high potential for poor air quality. The study focused on New York City (NYC) due to non-attainment with NAAQS standards, large exposed populations, and the existing goal of reducing pollutant emissions. The baseline demand response scenario simulated a 1.8% average reduction in NYC peak demand on 49 days throughout the summer. Nitrogen oxide and particulate matter less than 2.5 μm in diameter emission reductions were predicted to occur (−70, −1.1 metric tons (MT) annually), although, these were not likely to be sufficient for NYC to meet the NAAQS. Air pollution mediated damages were predicted to decrease by $100,000–$300,000 annually. A sensitivity analysis predicted that substantially larger pollutant emission reductions would occur if electricity demand was shifted from daytime hours to nighttime hours, or the total consumption decreased. Policies which incentivize shifting electricity consumption away from periods of high human and environmental impacts should be implemented, including policies directed toward residential consumers. - Highlights: • The impact of residential demand response on air emissions was modeled. • Residential demand response will decrease pollutant emissions in NYC. • Emissions reductions occur during periods with high potential for poor air quality. • Shifting demand to nighttime hours was more beneficial than to off-peak daytime hours

  2. Hydrogen burn assessment with the CONTAIN code

    International Nuclear Information System (INIS)

    van Rij, H.M.

    1986-01-01

    The CONTAIN computer code was developed at Sandia National Laboratories, under contract to the US Nuclear Regulatory Commission (NRC). The code is intended for calculations of containment loads during severe accidents and for prediction of the radioactive source term in the event that the containment leaks or fails. A strong point of the CONTAIN code is the continuous interaction of the thermal-hydraulics phenomena, aerosol behavior and fission product behavior. The CONTAIN code can be used for Light Water Reactors as well as Liquid Metal Reactors. In order to evaluate the CONTAIN code on its merits, comparisons between the code and experiments must be made. In this paper, CONTAIN calculations for the hydrogen burn experiments, carried out at the Nevada Test Site (NTS), are presented and compared with the experimental data. In the Large-Scale Hydrogen Combustion Facility at the NTS, 21 tests have been carried out. These tests were sponsored by the NRC and the Electric Power Research Institute (EPRI). The tests, carried out by EG and G, were performed in a spherical vessel 16 m in diameter with a design pressure of 700 kPa, substantially higher than that of most commercial nuclear containment buildings

  3. Performance of Different OCDMA Codes with FWM and XPM Nonlinear Effects

    Science.gov (United States)

    Rana, Shivani; Gupta, Amit

    2017-08-01

    In this paper, 1 Gb/s non-linear optical code division multiple access system have been simulated and modeled. To reduce multiple user interference multi-diagonal (MD) code which possesses the property of having zero cross-correlation have been deployed. The MD code shows better results than Walsh-Hadamard and multi-weight code under the nonlinear effect of four-wave mixing (FWM) and cross-phase modulation (XPM). The simulation results reveal that effect of FWM reduces when MD codes are employed as compared to other codes.

  4. Rapid installation of numerical models in multiple parent codes

    Energy Technology Data Exchange (ETDEWEB)

    Brannon, R.M.; Wong, M.K.

    1996-10-01

    A set of``model interface guidelines``, called MIG, is offered as a means to more rapidly install numerical models (such as stress-strain laws) into any parent code (hydrocode, finite element code, etc.) without having to modify the model subroutines. The model developer (who creates the model package in compliance with the guidelines) specifies the model`s input and storage requirements in a standardized way. For portability, database management (such as saving user inputs and field variables) is handled by the parent code. To date, NUG has proved viable in beta installations of several diverse models in vectorized and parallel codes written in different computer languages. A NUG-compliant model can be installed in different codes without modifying the model`s subroutines. By maintaining one model for many codes, MIG facilitates code-to-code comparisons and reduces duplication of effort potentially reducing the cost of installing and sharing models.

  5. Industrial Electricity. In-Plant Distribution. Vocational Trade and Industrial Education.

    Science.gov (United States)

    Teague, Cash; Pewewardy, Garner

    This curriculum guide, part of a series of industrial electricity curriculum guides, consists of materials for use in teaching a course on the in-plant distribution of electricity. Discussed in the introductory lessons are the National Electrical Code, power equipment, and blueprint reading. The next section, a series of units on branch-circuit…

  6. Towards advanced code simulators

    International Nuclear Information System (INIS)

    Scriven, A.H.

    1990-01-01

    The Central Electricity Generating Board (CEGB) uses advanced thermohydraulic codes extensively to support PWR safety analyses. A system has been developed to allow fully interactive execution of any code with graphical simulation of the operator desk and mimic display. The system operates in a virtual machine environment, with the thermohydraulic code executing in one virtual machine, communicating via interrupts with any number of other virtual machines each running other programs and graphics drivers. The driver code itself does not have to be modified from its normal batch form. Shortly following the release of RELAP5 MOD1 in IBM compatible form in 1983, this code was used as the driver for this system. When RELAP5 MOD2 became available, it was adopted with no changes needed in the basic system. Overall the system has been used for some 5 years for the analysis of LOBI tests, full scale plant studies and for simple what-if studies. For gaining rapid understanding of system dependencies it has proved invaluable. The graphical mimic system, being independent of the driver code, has also been used with other codes to study core rewetting, to replay results obtained from batch jobs on a CRAY2 computer system and to display suitably processed experimental results from the LOBI facility to aid interpretation. For the above work real-time execution was not necessary. Current work now centers on implementing the RELAP 5 code on a true parallel architecture machine. Marconi Simulation have been contracted to investigate the feasibility of using upwards of 100 processors, each capable of a peak of 30 MIPS to run a highly detailed RELAP5 model in real time, complete with specially written 3D core neutronics and balance of plant models. This paper describes the experience of using RELAP5 as an analyzer/simulator, and outlines the proposed methods and problems associated with parallel execution of RELAP5

  7. Stability analysis by ERATO code

    International Nuclear Information System (INIS)

    Tsunematsu, Toshihide; Takeda, Tatsuoki; Matsuura, Toshihiko; Azumi, Masafumi; Kurita, Gen-ichi

    1979-12-01

    Problems in MHD stability calculations by ERATO code are described; which concern convergence property of results, equilibrium codes, and machine optimization of ERATO code. It is concluded that irregularity on a convergence curve is not due to a fault of the ERATO code itself but due to inappropriate choice of the equilibrium calculation meshes. Also described are a code to calculate an equilibrium as a quasi-inverse problem and a code to calculate an equilibrium as a result of a transport process. Optimization of the code with respect to I/O operations reduced both CPU time and I/O time considerably. With the FACOM230-75 APU/CPU multiprocessor system, the performance is about 6 times as high as with the FACOM230-75 CPU, showing the effectiveness of a vector processing computer for the kind of MHD computations. This report is a summary of the material presented at the ERATO workshop 1979(ORNL), supplemented with some details. (author)

  8. CAT: a computer code for the automated construction of fault trees

    International Nuclear Information System (INIS)

    Apostolakis, G.E.; Salem, S.L.; Wu, J.S.

    1978-03-01

    A computer code, CAT (Computer Automated Tree, is presented which applies decision table methods to model the behavior of components for systematic construction of fault trees. The decision tables for some commonly encountered mechanical and electrical components are developed; two nuclear subsystems, a Containment Spray Recirculation System and a Consequence Limiting Control System, are analyzed to demonstrate the applications of CAT code

  9. Optimal patch code design via device characterization

    Science.gov (United States)

    Wu, Wencheng; Dalal, Edul N.

    2012-01-01

    In many color measurement applications, such as those for color calibration and profiling, "patch code" has been used successfully for job identification and automation to reduce operator errors. A patch code is similar to a barcode, but is intended primarily for use in measurement devices that cannot read barcodes due to limited spatial resolution, such as spectrophotometers. There is an inherent tradeoff between decoding robustness and the number of code levels available for encoding. Previous methods have attempted to address this tradeoff, but those solutions have been sub-optimal. In this paper, we propose a method to design optimal patch codes via device characterization. The tradeoff between decoding robustness and the number of available code levels is optimized in terms of printing and measurement efforts, and decoding robustness against noises from the printing and measurement devices. Effort is drastically reduced relative to previous methods because print-and-measure is minimized through modeling and the use of existing printer profiles. Decoding robustness is improved by distributing the code levels in CIE Lab space rather than in CMYK space.

  10. Electricity Recovery from Municipal Sewage Wastewater Using a Hydrogel Complex Composed of Microbially Reduced Graphene Oxide and Sludge

    Directory of Open Access Journals (Sweden)

    Naoko Yoshida

    2016-08-01

    Full Text Available Graphene oxide (GO has recently been shown to be an excellent anode substrate for exoelectrogens. This study demonstrates the applicability of GO in recovering electricity from sewage wastewater. Anaerobic incubation of sludge with GO formed a hydrogel complex that embeds microbial cells via π-π stacking of microbially reduced GO. The rGO complex was electrically conductive (23 mS·cm−1 and immediately produced electricity in sewage wastewater under polarization at +200 mV vs. Ag/AgCl. Higher and more stable production of electricity was observed with rGO complexes (179–310 μA·cm−3 than with graphite felt (GF; 79–95 μA·cm−3. Electrochemical analyses revealed that this finding was attributable to the greater capacitance and smaller internal resistance of the rGO complex. Microbial community analysis showed abundances of Geobacter species in both rGO and GF complexes, whereas more diverse candidate exoelectrogens in the Desulfarculaceae family and Geothrix genus were particularly prominent in the rGO complex.

  11. Driving with electrical power

    International Nuclear Information System (INIS)

    Ursin, M.; Hoeckel, M.

    2008-01-01

    This article takes a look at the chances offered to the electricity supply industry by the increasing use of battery-driven vehicles - and the advantages thus offered to the environment. The use of the vehicles' batteries to form a distributed electricity storage scheme is discussed. The authors comment that, although electrically-driven vehicles consume more power, the total primary energy consumption and pollutant emissions will be reduced. The actual electricity consumption of electric vehicles and the source of this power are examined. Power saved by the reduced use of electrical heating systems and boilers could, according to the authors, be used to charge the batteries of electric vehicles. The use of these batteries as a storage system to help regulate electricity supplies is discussed and the steps to be taken for the implementation of such a system are listed

  12. Impact of roof integrated PV orientation on the residential electricity peak demand

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Atallah, Fady; Boehm, Robert F.

    2012-01-01

    Highlights: ► A study to demonstrate peak load reductions at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 38% through energy efficiency. ► Orientation of roof integrated PV has less influence on the summer peak demand. ► Increasing thermostat temperature during peak by 1 °C can significantly reduce peaks. -- Abstract: Peak electricity demand has been an issue in the Desert Southwest region of the US, due to extreme summer temperatures. To address this issue, a consortium was formed between the University of Nevada, Las Vegas, Pulte Homes, and NV Energy. An energy efficient residential community was developed by the team in Las Vegas with approximately 200 homes to study substation-level peak reduction strategies. A summer peak reduction of more than 65%, between 1:00 PM and 7:00 PM, compared to code standard housing developments is the targeted goal of the project. Approximately 50 homes are already built and some are occupied. The energy performances of the homes have been monitored and are presented in this paper. Several peak electric load reduction strategies such as energy efficiency in buildings, roof integrated photovoltaics (PV) and direct load control have been applied. Though all the homes in the developed community are installed with 1.8 kW p PV systems, the orientation of the PV system depends on the building orientation. Focus of this paper is to find the impact of PV orientation on the peak load from a building. In addition, different time-of-use (TOU) energy pricing options are offered by the local electrical utility company. Hence it is important to find an optimal pricing option for each building. A computer model has been developed for one of the homes in the new development using building energy simulation code, ENERGY-10. Calculations on the PV orientations have shown that a south and 220° (i.e. 40° west of due south

  13. Chronic Electrical Stimulation at Acupoints Reduces Body Weight and Improves Blood Glucose in Obese Rats via Autonomic Pathway.

    Science.gov (United States)

    Liu, Jiemin; Jin, Haifeng; Foreman, Robert D; Lei, Yong; Xu, Xiaohong; Li, Shiying; Yin, Jieyun; Chen, Jiande D Z

    2015-07-01

    The aim of this study was to investigate effects and mechanisms of chronic electrical stimulation at acupoints (CEA) using surgically implanted electrodes on food intake, body weight, and metabolisms in diet-induced obese (DIO) rats. Thirty-six DIO rats were chronically implanted with electrodes at acupoints ST-36 (Zusanli). Three sets of parameters were tested: electrical acupuncture (EA) 1 (2-s on, 3-s off, 0.5 ms, 15 Hz, 6 mA), EA2 (same as EA1 but continuous pulses), and EA3 (same as EA2 but 10 mA). A chronic study was then performed to investigate the effects of CEA on body weight and mechanisms involving gastrointestinal hormones and autonomic functions. EA2 significantly reduced food intake without uncomfortable behaviors. CEA at EA2 reduced body weight and epididymal fat pad weight (P fasting plasma level of glucagon-like peptide-1 (GLP-1) and peptide YY (P < 0.05); the increase of GLP-1 was inversely correlated with postprandial blood glucose (R (2) = 0.89, P < 0.05); and the plasma ghrelin level remained unchanged. EA increased sympathetic activity (P < 0.01) and reduced vagal activity (P < 0.01). CEA at ST-36 reduces body weight and improves blood glucose possibly attributed to multiple mechanisms involving gastrointestinal motility and hormones via the autonomic pathway.

  14. Triboelectric-Based Transparent Secret Code.

    Science.gov (United States)

    Yuan, Zuqing; Du, Xinyu; Li, Nianwu; Yin, Yingying; Cao, Ran; Zhang, Xiuling; Zhao, Shuyu; Niu, Huidan; Jiang, Tao; Xu, Weihua; Wang, Zhong Lin; Li, Congju

    2018-04-01

    Private and security information for personal identification requires an encrypted tool to extend communication channels between human and machine through a convenient and secure method. Here, a triboelectric-based transparent secret code (TSC) that enables self-powered sensing and information identification simultaneously in a rapid process method is reported. The transparent and hydrophobic TSC can be conformed to any cambered surface due to its high flexibility, which extends the application scenarios greatly. Independent of the power source, the TSC can induce obvious electric signals only by surface contact. This TSC is velocity-dependent and capable of achieving a peak voltage of ≈4 V at a resistance load of 10 MΩ and a sliding speed of 0.1 m s -1 , according to a 2 mm × 20 mm rectangular stripe. The fabricated TSC can maintain its performance after reciprocating rolling for about 5000 times. The applications of TSC as a self-powered code device are demonstrated, and the ordered signals can be recognized through the height of the electric peaks, which can be further transferred into specific information by the processing program. The designed TSC has great potential in personal identification, commodity circulation, valuables management, and security defense applications.

  15. Adaptive distributed source coding.

    Science.gov (United States)

    Varodayan, David; Lin, Yao-Chung; Girod, Bernd

    2012-05-01

    We consider distributed source coding in the presence of hidden variables that parameterize the statistical dependence among sources. We derive the Slepian-Wolf bound and devise coding algorithms for a block-candidate model of this problem. The encoder sends, in addition to syndrome bits, a portion of the source to the decoder uncoded as doping bits. The decoder uses the sum-product algorithm to simultaneously recover the source symbols and the hidden statistical dependence variables. We also develop novel techniques based on density evolution (DE) to analyze the coding algorithms. We experimentally confirm that our DE analysis closely approximates practical performance. This result allows us to efficiently optimize parameters of the algorithms. In particular, we show that the system performs close to the Slepian-Wolf bound when an appropriate doping rate is selected. We then apply our coding and analysis techniques to a reduced-reference video quality monitoring system and show a bit rate saving of about 75% compared with fixed-length coding.

  16. Study of asymmetrical electric discharges using particle simulation

    International Nuclear Information System (INIS)

    Alves, M.V.

    1990-11-01

    Asymmetrical electric discharges are been widely used in the microelectronic industry. The asymmetry in the electrode areas determines the magnitude of the plasma-to-electrode voltage, V sub(a), at the powered electrode, which determines the ion bombarding energy, a critical plasma processing parameter. Two many-particle simulation codes, called P D C 1 and P D S 1, were developed. These codes are electrostatic, one-dimensional (radial) and model (a bounded plasma between two infinite cylinders or two concentric spheres that can be connected to a RLC external circuit. Both codes consider asymmetrical electrodes areas. In order to simulate electrical discharges, Monte-Carlo simulation of electron-neutral and ion-neutral collisions were included. These codes were used to study the relationship between the voltage area ratio across the sheaths, V sub(a) / V sub(b), and the electrode area ratio A sub(b) / A sub(a). Simulation results agree with experimental results and also with the analytical model that includes local ionization near the electrodes, observed to occur in almost all our simulations. (author)

  17. The benefits and costs of reducing emissions from the electricity sector.

    Science.gov (United States)

    Palmer, Karen; Burtraw, Dallas; Shih, Jhih-Shyang

    2007-04-01

    Recent federal policy proposals to reduce emissions of sulfur dioxide (SO(2)), nitrogen oxides (NO(x)), and mercury from the US electricity sector promise important improvements in air quality and reductions in acid deposition. The cost of achieving these reductions depends on the form and stringency of the regulation. In this research, we analyze the economic benefits and costs of the US Environmental Protection Agency's (EPA's) Clean Air Interstate Rule (CAIR) as characterized in the supplemental rule proposed in June 2004, and the Clean Air Mercury Rule (CAMR) as proposed in February 2004. The assessment integrates a model of the electricity sector, two models of atmospheric transport of air pollutants, and a model of environmental and public health endpoints affected by pollution. We model explicitly the emissions of SO(2), NO(x), mercury and carbon dioxide (CO(2)) and the effects of changes in emissions of SO(2) and NO(x) on environmental and public health. The manner in which mercury emissions are regulated will have important implications not only for the cost of the regulation, but also for emission levels for SO(2) and NO(x) and where those emissions are located. We find the economic benefits of CAIR and CAMR are far greater than the costs. Recent estimates of benefits of reductions in mercury and acidification indicate that our model captures the lion's share of quantifiable benefits. We also find that the EPA would have been justified on economic grounds in pursuing additional SO(2) emissions reductions beyond the requirements of CAIR.

  18. Consequences of reduced production of electricity in nuclear power plants

    International Nuclear Information System (INIS)

    The Swedish Power Administration has assessed the possibilities of expanding electric power sources other than nuclear power plants for the years 1980 and 1985. Reports on costs in the form of loss of capital and increased operating costs involved in the dismantling of nuclear power plants are made in Supplement 1. The economics division of the Finance Department, starting with a long-range study model of the Swedish economy, has calculated the consequences of a cutback in electric power up to 1980 for Sweden's economy and employment in that year. The consequences of reduction of electricity supplies up to 1985 are summarized in Supplement 2 in this report. It is concluded that in order to be able to manage the problem of supplying electricity by 1985, it will be necessary to increase oil power above what was assumed in the energy policy program. There will have to be new oil-based power as well. According to the Power Administration, oil-power facilities can be expanded to varying degrees, depending upon when the decision is made. The Power Administration's calculations show that 125 TWh is possible in 1985 without nuclear power only if a decision for discontinuation is made in the fall of 1976. This is based on very optimistic assumptions about the time of execution of a program for oil-steam operation, and also on the assumption that extreme measures will be initiated to force expansion of both district-heating distribution and power + heat facilities. Oil consumption for production of electricity in such an electric power system would be about 9 million m 3 , which is about 5 times more than at present and about one-third of the present total consumption of petroleum products in Sweden

  19. Data processing codes for fatigue and tensile tests

    International Nuclear Information System (INIS)

    Sanchez Sarmiento, Gustavo; Iorio, A.F.; Crespi, J.C.

    1981-01-01

    The processing of fatigue and tensile tests data in order to obtain several parameters of engineering interest requires a considerable effort of numerical calculus. In order to reduce the time spent in this work and to establish standard data processing from a set of similar type tests, it is very advantageous to have a calculation code for running in a computer. Two codes have been developed in FORTRAN language; one of them predicts cyclic properties of materials from the monotonic and incremental or multiple cyclic step tests (ENSPRED CODE), and the other one reduces data coming from strain controlled low cycle fatigue tests (ENSDET CODE). Two examples are included using Zircaloy-4 material from different manufacturers. (author) [es

  20. Reducing electricity demand peaks by scheduling home appliances usage

    Energy Technology Data Exchange (ETDEWEB)

    Rossello-Busquet, A.; Kardaras, G.; Baek Iversen, V.; Soler, J.; Dittmann, L.

    2011-05-15

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users' appliances should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions. On the contrary, the low priority devices have to pause their operation, when the algorithm dictates it, and resume it in the future. This can become beneficial for both energy companies and users. The electricity suppliers companies will be capable of regulating power generation during demand peaks periods. Moreover, users can be granted lower electricity bill rates for accepting delaying the operation of some of their appliances. In order to analyze this scenario, teletraffic engineering theory, which is used in evaluating the performance of telecommunication networks, is used. A reversible fair scheduling (RFS) algorithm, which was originally developed for telecommunication networks, is applied. The purpose is to analyze how a power consumption limit and priorities for home appliances will affect the demand peak and the users' everyday life. Verification of the effectiveness of the RFS algorithm is done by means of simulation and by using real data for power consumption and operation hours. The defined maximum power limit of 750 and 1000 Watt was not exceeded during

  1. Asheville, North Carolina: Reducing Electricity Demand through Building Programs & Policies (City Energy: From Data to Decisions)

    Energy Technology Data Exchange (ETDEWEB)

    Office of Strategic Programs, Strategic Priorities and Impact Analysis Team

    2017-09-29

    This fact sheet "Asheville, North Carolina: Reducing Electricity Demand through Building Programs & Policies" explains how the City of Asheville used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.

  2. NSPEC - A neutron spectrum code for beam-heated fusion plasmas

    International Nuclear Information System (INIS)

    Scheffel, J.

    1983-06-01

    A 3-dimensional computer code is described, which computes neutron spectra due to beam heating of fusion plasmas. Three types of interactions are considered; thermonuclear of plasma-plasma, beam-plasma and beam-beam interactions. Beam deposition is modelled by the NFREYA code. The applied steady state beam distribution as a function of pitch angle and velocity contains the effects of energy diffusion, friction, angular scattering, charge exchange, electric field and source pitch angle distribution. The neutron spectra, generated by Monte-Carlo methods, are computed with respect to given lines of sight. This enables the code to be used for neutron diagnostics. (author)

  3. Low Computational Complexity Network Coding For Mobile Networks

    DEFF Research Database (Denmark)

    Heide, Janus

    2012-01-01

    Network Coding (NC) is a technique that can provide benefits in many types of networks, some examples from wireless networks are: In relay networks, either the physical or the data link layer, to reduce the number of transmissions. In reliable multicast, to reduce the amount of signaling and enable......-flow coding technique. One of the key challenges of this technique is its inherent computational complexity which can lead to high computational load and energy consumption in particular on the mobile platforms that are the target platform in this work. To increase the coding throughput several...

  4. Interface requirements for coupling a containment code to a reactor system thermal hydraulic codes

    International Nuclear Information System (INIS)

    Baratta, A.J.

    1997-01-01

    To perform a complete analysis of a reactor transient, not only the primary system response but the containment response must also be accounted for. Such transients and accidents as a loss of coolant accident in both pressurized water and boiling water reactors and inadvertent operation of safety relief valves all challenge the containment and may influence flows because of containment feedback. More recently, the advanced reactor designs put forth by General Electric and Westinghouse in the US and by Framatome and Seimens in Europe rely on the containment to act as the ultimate heat sink. Techniques used by analysts and engineers to analyze the interaction of the containment and the primary system were usually iterative in nature. Codes such as RELAP or RETRAN were used to analyze the primary system response and CONTAIN or CONTEMPT the containment response. The analysis was performed by first running the system code and representing the containment as a fixed pressure boundary condition. The flows were usually from the primary system to the containment initially and generally under choked conditions. Once the mass flows and timing are determined from the system codes, these conditions were input into the containment code. The resulting pressures and temperatures were then calculated and the containment performance analyzed. The disadvantage of this approach becomes evident when one performs an analysis of a rapid depressurization or a long term accident sequence in which feedback from the containment can occur. For example, in a BWR main steam line break transient, the containment heats up and becomes a source of energy for the primary system. Recent advances in programming and computer technology are available to provide an alternative approach. The author and other researchers have developed linkage codes capable of transferring data between codes at each time step allowing discrete codes to be coupled together

  5. Interface requirements for coupling a containment code to a reactor system thermal hydraulic codes

    Energy Technology Data Exchange (ETDEWEB)

    Baratta, A.J.

    1997-07-01

    To perform a complete analysis of a reactor transient, not only the primary system response but the containment response must also be accounted for. Such transients and accidents as a loss of coolant accident in both pressurized water and boiling water reactors and inadvertent operation of safety relief valves all challenge the containment and may influence flows because of containment feedback. More recently, the advanced reactor designs put forth by General Electric and Westinghouse in the US and by Framatome and Seimens in Europe rely on the containment to act as the ultimate heat sink. Techniques used by analysts and engineers to analyze the interaction of the containment and the primary system were usually iterative in nature. Codes such as RELAP or RETRAN were used to analyze the primary system response and CONTAIN or CONTEMPT the containment response. The analysis was performed by first running the system code and representing the containment as a fixed pressure boundary condition. The flows were usually from the primary system to the containment initially and generally under choked conditions. Once the mass flows and timing are determined from the system codes, these conditions were input into the containment code. The resulting pressures and temperatures were then calculated and the containment performance analyzed. The disadvantage of this approach becomes evident when one performs an analysis of a rapid depressurization or a long term accident sequence in which feedback from the containment can occur. For example, in a BWR main steam line break transient, the containment heats up and becomes a source of energy for the primary system. Recent advances in programming and computer technology are available to provide an alternative approach. The author and other researchers have developed linkage codes capable of transferring data between codes at each time step allowing discrete codes to be coupled together.

  6. Experimental Evaluation of Simple Thermal Storage Control Strategies in Low-Energy Solar Houses to Reduce Electricity Consumption during Grid On-Peak Periods

    Directory of Open Access Journals (Sweden)

    Kyoung-Ho Lee

    2015-08-01

    Full Text Available There is growing interest in zero-energy and low-energy buildings, which have a net energy consumption (on an annual basis of almost zero. Because they can generate both electricity and thermal energy through the use of solar photovoltaic (PV and solar thermal collectors, and with the help of reduced building thermal demand, low-energy buildings can not only make a significant contribution to energy conservation on an annual basis, but also reduce energy consumption and peak demand. This study focused on electricity consumption during the on-peak period in a low-energy residential solar building and considers the use of a building’s thermal mass and thermal storage to reduce electricity consumption in summer and winter by modulation of temperature setpoints for heat pump and indoor thermostats in summer and additional use of a solar heating loop in winter. Experiments were performed at a low-energy solar demonstration house that has solar collectors, hot water storage, a ground-coupled heat pump, and a thermal storage tank. It was assumed that the on-peak periods were from 2 pm to 5 pm on hot summer days and from 5 pm to 8 pm on cold winter days. To evaluate the potential for utilizing the building’s thermal storage capacity in space cooling and heating, the use of simple control strategies on three test days in summer and two test days in the early spring were compared in terms of net electricity consumption and peak demand, which also considered the electricity generation from solar PV modules on the roof of the house.

  7. DART: A simulation code for charged particle beams

    International Nuclear Information System (INIS)

    White, R.C.; Barr, W.L.; Moir, R.W.

    1989-01-01

    This paper presents a recently modified version of the 2-D code, DART, which can simulate the behavior of a beam of charged particles whose trajectories are determined by electric and magnetic fields. This code was originally used to design laboratory-scale and full-scale beam direct converters. Since then, its utility has been expanded to allow more general applications. The simulation includes space charge, secondary electrons, and the ionization of neutral gas. A beam can contain up to nine superimposed beamlets of different energy and species. The calculation of energy conversion efficiency and the method of specifying the electrode geometry are described. Basic procedures for using the code are given, and sample input and output fields are shown. 7 refs., 18 figs

  8. Neoclassical Simulation of Tokamak Plasmas using Continuum Gyrokinetc Code TEMPEST

    International Nuclear Information System (INIS)

    Xu, X Q

    2007-01-01

    We present gyrokinetic neoclassical simulations of tokamak plasmas with self-consistent electric field for the first time using a fully nonlinear (full-f) continuum code TEMPEST in a circular geometry. A set of gyrokinetic equations are discretized on a five dimensional computational grid in phase space. The present implementation is a Method of Lines approach where the phase-space derivatives are discretized with finite differences and implicit backwards differencing formulas are used to advance the system in time. The fully nonlinear Boltzmann model is used for electrons. The neoclassical electric field is obtained by solving gyrokinetic Poisson equation with self-consistent poloidal variation. With our 4D (ψ, θ, ε, μ) version of the TEMPEST code we compute radial particle and heat flux, the Geodesic-Acoustic Mode (GAM), and the development of neoclassical electric field, which we compare with neoclassical theory with a Lorentz collision model. The present work provides a numerical scheme and a new capability for self-consistently studying important aspects of neoclassical transport and rotations in toroidal magnetic fusion devices

  9. Fuel management and core design code systems for pressurized water reactor neutronic calculations

    International Nuclear Information System (INIS)

    Ahnert, C.; Arayones, J.M.

    1985-01-01

    A package of connected code systems for the neutronic calculations relevant in fuel management and core design has been developed and applied for validation to the startup tests and first operating cycle of a 900MW (electric) PWR. The package includes the MARIA code system for the modeling of the different types of PWR fuel assemblies, the CARMEN code system for detailed few group diffusion calculations for PWR cores at operating and burnup conditions, and the LOLA code system for core simulation using onegroup nodal theory parameters explicitly calculated from the detailed solutions

  10. ITS - The integrated TIGER series of coupled electron/photon Monte Carlo transport codes

    International Nuclear Information System (INIS)

    Halbleib, J.A.; Mehlhorn, T.A.

    1985-01-01

    The TIGER series of time-independent coupled electron/photon Monte Carlo transport codes is a group of multimaterial, multidimensional codes designed to provide a state-of-the-art description of the production and transport of the electron/photon cascade. The codes follow both electrons and photons from 1.0 GeV down to 1.0 keV, and the user has the option of combining the collisional transport with transport in macroscopic electric and magnetic fields of arbitrary spatial dependence. Source particles can be either electrons or photons. The most important output data are (a) charge and energy deposition profiles, (b) integral and differential escape coefficients for both electrons and photons, (c) differential electron and photon flux, and (d) pulse-height distributions for selected regions of the problem geometry. The base codes of the series differ from one another primarily in their dimensionality and geometric modeling. They include (a) a one-dimensional multilayer code, (b) a code that describes the transport in two-dimensional axisymmetric cylindrical material geometries with a fully three-dimensional description of particle trajectories, and (c) a general three-dimensional transport code which employs a combinatorial geometry scheme. These base codes were designed primarily for describing radiation transport for those situations in which the detailed atomic structure of the transport medium is not important. For some applications, it is desirable to have a more detailed model of the low energy transport. The system includes three additional codes that contain a more elaborate ionization/relaxation model than the base codes. Finally, the system includes two codes that combine the collisional transport of the multidimensional base codes with transport in macroscopic electric and magnetic fields of arbitrary spatial dependence

  11. Formation of electron-root radial electric field and its effect on thermal transport in LHD high Te plasma

    International Nuclear Information System (INIS)

    Matsuoka, Seikichi; Satake, Shinsuke; Takahashi, Hiromi; Yokoyama, Masayuki; Ido, Takeshi; Shimizu, Akihiro; Shimozuma, Takashi; Wakasa, Arimitsu; Murakami, Sadayoshi

    2013-01-01

    Neoclassical transport analyses have been performed for a high electron temperature LHD plasma with steep temperature gradient using a neoclassical transport simulation code, FORTEC-3D. It is shown that the large positive radial electric field is spontaneously formed at the core along with the increase in the electron temperature, while the neoclassical heat diffusivity remains almost unchanged. This indicates that the 1/ν-type increase expected in the neoclassical transport in helical plasmas can be avoided by the spontaneous formation of the radial electric field. At the same time, it is found that the experimentally estimated heat diffusivity is significantly reduced. This suggests that the formation process of the transport barrier in the high electron temperature plasma can be caused by the spontaneous formation of the radial electric field. (author)

  12. Bounded-Angle Iterative Decoding of LDPC Codes

    Science.gov (United States)

    Dolinar, Samuel; Andrews, Kenneth; Pollara, Fabrizio; Divsalar, Dariush

    2009-01-01

    Bounded-angle iterative decoding is a modified version of conventional iterative decoding, conceived as a means of reducing undetected-error rates for short low-density parity-check (LDPC) codes. For a given code, bounded-angle iterative decoding can be implemented by means of a simple modification of the decoder algorithm, without redesigning the code. Bounded-angle iterative decoding is based on a representation of received words and code words as vectors in an n-dimensional Euclidean space (where n is an integer).

  13. 2-Step scalar deadzone quantization for bitplane image coding.

    Science.gov (United States)

    Auli-Llinas, Francesc

    2013-12-01

    Modern lossy image coding systems generate a quality progressive codestream that, truncated at increasing rates, produces an image with decreasing distortion. Quality progressivity is commonly provided by an embedded quantizer that employs uniform scalar deadzone quantization (USDQ) together with a bitplane coding strategy. This paper introduces a 2-step scalar deadzone quantization (2SDQ) scheme that achieves same coding performance as that of USDQ while reducing the coding passes and the emitted symbols of the bitplane coding engine. This serves to reduce the computational costs of the codec and/or to code high dynamic range images. The main insights behind 2SDQ are the use of two quantization step sizes that approximate wavelet coefficients with more or less precision depending on their density, and a rate-distortion optimization technique that adjusts the distortion decreases produced when coding 2SDQ indexes. The integration of 2SDQ in current codecs is straightforward. The applicability and efficiency of 2SDQ are demonstrated within the framework of JPEG2000.

  14. Code of safety for nuclear merchant ships

    International Nuclear Information System (INIS)

    1982-01-01

    The Code is in chapters, entitled: general (including general safety principles and principles of risk acceptance); design criteria and conditions; ship design, construction and equipment; nuclear steam supply system; machinery and electrical installations; radiation safety (including radiological protection design; protection of persons; dosimetry; radioactive waste management); operation (including emergency operation procedures); surveys. Appendices cover: sinking velocity calculations; seaway loads depending on service periods; safety assessment; limiting dose-equivalent rates for different areas and spaces; quality assurance programme; application of single failure criterion. Initial application of the Code is restricted to conventional types of ships propelled by nuclear propulsion plants with pressurized light water type reactors. (U.K.)

  15. Optimal codes as Tanner codes with cyclic component codes

    DEFF Research Database (Denmark)

    Høholdt, Tom; Pinero, Fernando; Zeng, Peng

    2014-01-01

    In this article we study a class of graph codes with cyclic code component codes as affine variety codes. Within this class of Tanner codes we find some optimal binary codes. We use a particular subgraph of the point-line incidence plane of A(2,q) as the Tanner graph, and we are able to describe ...

  16. Content layer progressive coding of digital maps

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Jensen, Ole Riis

    2000-01-01

    A new lossless context based method is presented for content progressive coding of limited bits/pixel images, such as maps, company logos, etc., common on the WWW. Progressive encoding is achieved by separating the image into content layers based on other predefined information. Information from...... already coded layers are used when coding subsequent layers. This approach is combined with efficient template based context bi-level coding, context collapsing methods for multi-level images and arithmetic coding. Relative pixel patterns are used to collapse contexts. The number of contexts are analyzed....... The new methods outperform existing coding schemes coding digital maps and in addition provide progressive coding. Compared to the state-of-the-art PWC coder, the compressed size is reduced to 60-70% on our layered test images....

  17. Nuclear electricity generation a sustainable energy resource for Romania along the next two decades

    International Nuclear Information System (INIS)

    Prodea, Iosif; Margeanu, Cristina Alice; Aioanei, Corina; Prisecaru, Ilie; Danila, Nicolae

    2008-01-01

    The main goal of the paper is to evaluate different electricity generation costs inside of the National Romanian energy sector along the next two decades. The IAEA -MESSAGE code (Model for Energy Supply Strategy Alternatives and their General Environmental Impacts) will be used to accomplish these assessments. Due to the natural gas crisis started at the beginning of 2006, Romania has adopted a courageous energy policy based on increasing nuclear electricity share. Since then, the second nuclear Unit was commissioned at Cernavoda in 2007 and the other two CANDU-6 (700 MWe) were scheduled to be operational in 2015. On the other side the European integration of Romania asks for doubling the indigenous gas price during this year, 2008, and also for reducing the atmospheric gaseous emissions from the fossil fuel technologies. Therefore, we evaluated the economical competition between all electricity technologies in the Romanian energy sector in the next two decades for which our MESSAGE model was developed. We focused on coal, gas and, of course, nuclear electricity technologies. Some representative energy scenarios centered on nuclear share electricity growing were considered and MESSAGE results were analyzed from the energetic sustainable point of view. (authors)

  18. Decentralized Electric Vehicle Charging Strategies for Reduced Load Variation and Guaranteed Charge Completion in Regional Distribution Grids

    Directory of Open Access Journals (Sweden)

    Weige Zhang

    2017-01-01

    Full Text Available A novel, fully decentralized strategy to coordinate charge operation of electric vehicles is proposed in this paper. Based on stochastic switching control of on-board chargers, this strategy ensures high-efficiency charging, reduces load variations to the grid during charging periods, achieves charge completion with high probability, and accomplishes approximate “valley-filling”. Further improvements on the core strategy, including individualized power management, adaptive strategies, and battery support systems, are introduced to further reduce power fluctuation variances and to guarantee charge completion. Stochastic analysis is performed to establish the main properties of the strategies and to quantitatively show the performance improvements. Compared with the existing decentralized charging strategies, the strategies proposed in this paper can be implemented without any information exchange between grid operators and electric vehicles (EVs, resulting in a communications cost reduction. Additionally, it is shown that by using stochastic charging rules, a grid-supporting battery system with a very small energy capacity can achieve substantial reduction of EV load fluctuations with high confidence. An extensive set of simulations and case studies with real-world data are used to demonstrate the benefits of the proposed strategies.

  19. The electricity prices in the European Union. The role of renewable energies and regulatory electric market reforms

    International Nuclear Information System (INIS)

    Moreno, Blanca; López, Ana J.; García-Álvarez, María Teresa

    2012-01-01

    The European Union electricity market has been gradually liberalized since 1990s. Theoretically, competitive markets should lead to efficiency gains in the economy thus reducing electricity prices. However, there is a controversial debate about the real effects of the electricity liberalization on electricity prices. Moreover, the increased generation of electricity from renewable energies RES-E (Electricity from Renewable Energy Sources) is also integrated in wholesale market reducing wholesale prices, but the final effect over household prices is not clear. In order to contribute to this debate, this paper provides an empirical investigation into the electricity prices determinants. In fact we develop econometric panel models to explore the relationship between the household electricity prices and variables related to the renewable energy sources and the competition in generation electricity market. More specifically we use a panel data set provided by Eurostat and covering 27 European Union countries during the period 1998–2009. Our results suggest that electricity prices increase with the deployment of RES-E and with the expansion of greenhouse gas emissions produced by energy industries- as a European Union CO 2 emission trading scheme exists. Results also reveal that country's characteristics can affect household electricity prices. -- Highlights: ► Electricity liberalized markets should lead to reduce electricity prices. ► The use of renewable energies (RES) reduce wholesale electricity prices. ► However, household electricity prices are increasing in European Union. ► Panel data models are developed to investigate the effect of RES and electricity competition on household electricity prices. ► We find that the deployment of RES increases prices paid by consumers in a liberalized market.

  20. Verification of three dimensional triangular prismatic discrete ordinates transport code ENSEMBLE-TRIZ by comparison with Monte Carlo code GMVP

    International Nuclear Information System (INIS)

    Homma, Y.; Moriwaki, H.; Ikeda, K.; Ohdi, S.

    2013-01-01

    This paper deals with the verification of the 3 dimensional triangular prismatic discrete ordinates transport calculation code ENSEMBLE-TRIZ by comparison with the multi-group Monte Carlo calculation code GMVP in a large fast breeder reactor. The reactor is a 750 MWe electric power sodium cooled reactor. Nuclear characteristics are calculated at the beginning of cycle of an initial core and at the beginning and the end of cycle of an equilibrium core. According to the calculations, the differences between the two methodologies are smaller than 0.0002 Δk in the multiplication factor, relatively about 1% in the control rod reactivity, and 1% in the sodium void reactivity. (authors)

  1. Performance optimization of spectral amplitude coding OCDMA system using new enhanced multi diagonal code

    Science.gov (United States)

    Imtiaz, Waqas A.; Ilyas, M.; Khan, Yousaf

    2016-11-01

    This paper propose a new code to optimize the performance of spectral amplitude coding-optical code division multiple access (SAC-OCDMA) system. The unique two-matrix structure of the proposed enhanced multi diagonal (EMD) code and effective correlation properties, between intended and interfering subscribers, significantly elevates the performance of SAC-OCDMA system by negating multiple access interference (MAI) and associated phase induce intensity noise (PIIN). Performance of SAC-OCDMA system based on the proposed code is thoroughly analyzed for two detection techniques through analytic and simulation analysis by referring to bit error rate (BER), signal to noise ratio (SNR) and eye patterns at the receiving end. It is shown that EMD code while using SDD technique provides high transmission capacity, reduces the receiver complexity, and provides better performance as compared to complementary subtraction detection (CSD) technique. Furthermore, analysis shows that, for a minimum acceptable BER of 10-9 , the proposed system supports 64 subscribers at data rates of up to 2 Gbps for both up-down link transmission.

  2. Coding chaotic billiards. Pt. 3

    International Nuclear Information System (INIS)

    Ullmo, D.; Giannoni, M.J.

    1993-01-01

    Non-tiling compact billiard defined on the pseudosphere is studied 'a la Morse coding'. As for most bounded systems, the coding is non exact. However, two sets of approximate grammar rules can be obtained, one specifying forbidden codes, and the other allowed ones. In-between some sequences remain in the 'unknown' zone, but their relative amount can be reduced to zero if one lets the length of the approximate grammar rules goes to infinity. The relationship between these approximate grammar rules and the 'pruning front' introduced by Cvitanovic et al. is discussed. (authors). 13 refs., 10 figs., 1 tab

  3. Development of the computer code system for the analyses of PWR core

    International Nuclear Information System (INIS)

    Tsujimoto, Iwao; Naito, Yoshitaka.

    1992-11-01

    This report is one of the materials for the work titled 'Development of the computer code system for the analyses of PWR core phenomena', which is performed under contracts between Shikoku Electric Power Company and JAERI. In this report, the numerical method adopted in our computer code system are described, that is, 'The basic course and the summary of the analysing method', 'Numerical method for solving the Boltzmann equation', 'Numerical method for solving the thermo-hydraulic equations' and 'Description on the computer code system'. (author)

  4. Electrical charging characteristics of the hetero layer film for reducing water-borne paint contamination in electrostatic rotary atomizers

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y.; Imanishi, T.; Yoshida, O.; Mizuno, A. [ABB Japan, Tokyo (Japan)

    2010-07-01

    The electrostatic rotary atomizer is the most efficient of all liquid spray painting methods. Its use minimizes the waste of paint and reduces emissions of volatile organic compounds (VOCs). Water-borne painting processes which use water-soluble paint also reduce VOC emissions, but the atomizer body is easily contaminated by the paint mists. The Institute of Electrical and Electronics Engineers (IEEE) considered the causes of water-borne paint contamination and presented the experimental results of a contamination proof system in which the atomizer is surrounded by the repelling film that is charged and repels the incoming paint droplets. Among the key factors for repelling film were electrical properties, such as low capacitance and high insulation to keep high surface potential. Charging uniformity was found to be among the most important characteristic to avoid contamination. The pulse electro-acoustic (PEA) method was used to check these features using space charge measurements inside the repelling film. It was concluded that hetero layer films have more uniform charging characteristics than single layer films.

  5. DART: a simulation code for charged particle beams

    International Nuclear Information System (INIS)

    White, R.C.; Barr, W.L.; Moir, R.W.

    1988-01-01

    This paper presents a recently modified verion of the 2-D DART code designed to simulate the behavior of a beam of charged particles whose paths are affected by electric and magnetic fields. This code was originally used to design laboratory-scale and full-scale beam direct converters. Since then, its utility has been expanded to allow more general applications. The simulation technique includes space charge, secondary electron effects, and neutral gas ionization. Calculations of electrode placement and energy conversion efficiency are described. Basic operation procedures are given including sample input files and output. 7 refs., 18 figs

  6. MCTP, a code for the thermo-mechanical analysis of a fuel rod of BWR type reactors (Neutron part)

    International Nuclear Information System (INIS)

    Hernandez L, H.; Ortiz V, J.

    2003-01-01

    In the National Institute of Nuclear Research of Mexico a code for the thermo-mechanical analysis of the fuel rods of the BWR type reactors of the Nucleo electric Central of Laguna Verde is developed. The code solves the diffusion equation in cylindrical coordinates with several energy groups. The code, likewise, calculates the temperature distribution and power distribution in those fuel rods. The code is denominated Multi groups With Temperatures and Power (MCTP). In the code, the energy with which the fission neutrons are emitted it is divided in six groups. They are also considered the produced perturbations by the changes in the temperatures of the materials that constitute the fuel rods, the content of fission products, the uranium consumption and in its case the gadolinium, as well as the plutonium production. In this work there are present preliminary results obtained with the code, using data of operation of the Nucleo electric Central of Laguna Verde. (Author)

  7. 3D electric field calculation with surface charge method

    International Nuclear Information System (INIS)

    Yamada, S.

    1992-01-01

    This paper describes an outline and some examples of three dimensional electric field calculations with a computer code developed at NIRS. In the code, a surface charge method is adopted because of it's simplicity in the mesh establishing procedure. The charge density in a triangular mesh is assumed to distribute with a linear function of the position. The electric field distribution is calculated for a pair of drift tubes with the focusing fingers on the opposing surfaces. The field distribution in an acceleration gap is analyzed with a Fourier-Bessel series expansion method. The calculated results excellently reproduces the measured data with a magnetic model. (author)

  8. Electrical safety in flammable gas/vapor laden atmospheres

    CERN Document Server

    Korver, WOE

    1992-01-01

    This book provides comprehensive coverage of electrical system installation within areas where flammable gases and liquids are handled and processed. The accurate hazard evaluation of flammability risks associated with chemical and petrochemical locations is critical in determining the point at which the costs of electrical equipment and installation are balanced with explosion safety requirements. The book offers the most current code requirements along with tables and illustrations as analytic tools. Environmental characteristics are covered in Section 1 along with recommended electrical ins

  9. Transcutaneous electrical nerve stimulation reduces acute low back pain during emergency transport.

    Science.gov (United States)

    Bertalanffy, Alexander; Kober, Alexander; Bertalanffy, Petra; Gustorff, Burkhard; Gore, Odette; Adel, Sharam; Hoerauf, Klaus

    2005-07-01

    Patients with acute low back pain may require emergency transport because of pain and immobilization. Transcutaneous electrical nerve stimulation (TENS) is a nonpharmaceutical therapy for patients with low back pain. To evaluate the efficacy of paramedic-administered TENS in patients with acute low back pain during emergency transport. This was a prospective, randomized study involving 74 patients transported to hospital. The patients were randomly assigned to two groups: group 1 (n = 36) was treated with true TENS, while group 2 (n = 36) was treated with sham TENS. The authors recorded pain and anxiety as the main outcome variables using a visual analog scale (VAS). The authors recorded a significant (p pain reduction (mean +/- standard deviation) during transport in group 1 (79.2 +/- 6.5 mm VAS to 48.9 +/- 8.2 mm VAS), whereas pain scores remained unchanged in group 2 (75.9 +/- 16.4 mm VAS and 77.1 +/- 11.2 mm VAS). Similarly, the scores for anxiety were significantly reduced (p TENS was found to be effective and rapid in reducing pain during emergency transport of patients with acute low back pain and should be considered due to its ease of use and lack of side effects in the study population.

  10. Content Layer progressive Coding of Digital Maps

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Jensen, Ole Riis

    2002-01-01

    A new lossless context based method is presented for content progressive coding of limited bits/pixel images, such as maps, company logos, etc., common on the World Wide Web. Progressive encoding is achieved by encoding the image in content layers based on color level or other predefined...... information. Information from already coded layers are used when coding subsequent layers. This approach is combined with efficient template based context bilevel coding, context collapsing methods for multilevel images and arithmetic coding. Relative pixel patterns are used to collapse contexts. Expressions...... for calculating the resulting number of contexts are given. The new methods outperform existing schemes coding digital maps and in addition provide progressive coding. Compared to the state-of-the-art PWC coder, the compressed size is reduced to 50-70% on our layered map test images....

  11. A Novel Arc Fault Detector for Early Detection of Electrical Fires.

    Science.gov (United States)

    Yang, Kai; Zhang, Rencheng; Yang, Jianhong; Liu, Canhua; Chen, Shouhong; Zhang, Fujiang

    2016-04-09

    Arc faults can produce very high temperatures and can easily ignite combustible materials; thus, they represent one of the most important causes of electrical fires. The application of arc fault detection, as an emerging early fire detection technology, is required by the National Electrical Code to reduce the occurrence of electrical fires. However, the concealment, randomness and diversity of arc faults make them difficult to detect. To improve the accuracy of arc fault detection, a novel arc fault detector (AFD) is developed in this study. First, an experimental arc fault platform is built to study electrical fires. A high-frequency transducer and a current transducer are used to measure typical load signals of arc faults and normal states. After the common features of these signals are studied, high-frequency energy and current variations are extracted as an input eigenvector for use by an arc fault detection algorithm. Then, the detection algorithm based on a weighted least squares support vector machine is designed and successfully applied in a microprocessor. Finally, an AFD is developed. The test results show that the AFD can detect arc faults in a timely manner and interrupt the circuit power supply before electrical fires can occur. The AFD is not influenced by cross talk or transient processes, and the detection accuracy is very high. Hence, the AFD can be installed in low-voltage circuits to monitor circuit states in real-time to facilitate the early detection of electrical fires.

  12. A Novel Arc Fault Detector for Early Detection of Electrical Fires

    Science.gov (United States)

    Yang, Kai; Zhang, Rencheng; Yang, Jianhong; Liu, Canhua; Chen, Shouhong; Zhang, Fujiang

    2016-01-01

    Arc faults can produce very high temperatures and can easily ignite combustible materials; thus, they represent one of the most important causes of electrical fires. The application of arc fault detection, as an emerging early fire detection technology, is required by the National Electrical Code to reduce the occurrence of electrical fires. However, the concealment, randomness and diversity of arc faults make them difficult to detect. To improve the accuracy of arc fault detection, a novel arc fault detector (AFD) is developed in this study. First, an experimental arc fault platform is built to study electrical fires. A high-frequency transducer and a current transducer are used to measure typical load signals of arc faults and normal states. After the common features of these signals are studied, high-frequency energy and current variations are extracted as an input eigenvector for use by an arc fault detection algorithm. Then, the detection algorithm based on a weighted least squares support vector machine is designed and successfully applied in a microprocessor. Finally, an AFD is developed. The test results show that the AFD can detect arc faults in a timely manner and interrupt the circuit power supply before electrical fires can occur. The AFD is not influenced by cross talk or transient processes, and the detection accuracy is very high. Hence, the AFD can be installed in low-voltage circuits to monitor circuit states in real-time to facilitate the early detection of electrical fires. PMID:27070618

  13. Electricity prices and generator behaviour in gross pool electricity markets

    International Nuclear Information System (INIS)

    O'Mahoney, Amy; Denny, Eleanor

    2013-01-01

    Electricity market liberalisation has become common practice internationally. The justification for this process has been to enhance competition in a market traditionally characterised by statutory monopolies in an attempt to reduce costs to end-users. This paper endeavours to see whether a pool market achieves this goal of increasing competition and reducing electricity prices. Here the electricity market is set up as a sealed bid second price auction. Theory predicts that such markets should result with firms bidding their marginal cost, thereby resulting in an efficient outcome and lower costs to consumers. The Irish electricity system with a gross pool market experiences among the highest electricity prices in Europe. Thus, we analyse the Irish pool system econometrically in order to test if the high electricity prices seen there are due to participants bidding outside of market rules or out of line with theory. Overall we do not find any evidence that the interaction between generator and the pool in the Irish electricity market is not efficient. Thus, the pool element of the market structure does not explain the high electricity prices experienced in Ireland. - Highlights: • We consider whether a gross pool achieves competitive behaviour. • We analyse the Irish pool system econometrically. • Results indicate the Irish pool system appears to work efficiently. • Generators appear to be bidding appropriately

  14. Improving performance and reducing costs of cooling towers

    International Nuclear Information System (INIS)

    Bartz, J.A.

    1992-01-01

    Cooling towers represent a significant capital investment at a steam electric power station. In addition, deficiencies in thermal performance can result in major operating penalties of fuel cost, replacement energy, and capacity addition. This paper summarizes two recent EPRI research projects aimed at reducing thermal performance deficiencies and decreasing installed costs of evaporative cooling towers. First, EPRI Research Project 2113, Cooling Tower Performance Prediction and Improvement, is summarized. This project has resulted in published data sets on the measured thermal performance characteristics of a variety of cooling tower packings, computer codes to predict tower performance, and computer code validation through large-scale tower performance measurements. Principal results are contained in an EPRIGEMS software module, Cooling Tower Advisor. This PC- based software contains a tutorial plus codes to predict tower thermal performance, arranged in a user-friendly format. The second EPRI effort, Research Project 2819-10/11, Fabric Structures for Power Plant Applications, has resulted in designs and costs of large structures with shells constructed of recently-developed fabrics. Primary power plant applications for such structures are the shells of natural draft cooling towers and coal-pile covers. Fabric structures offer low initial cost, acceptable life, and seismic superiority, among other advantages. Detailed conceptual designs and installed cost data are reviewed. 8 refs., 9 figs., 3 tabs

  15. Benchmarking of FA2D/PARCS Code Package

    International Nuclear Information System (INIS)

    Grgic, D.; Jecmenica, R.; Pevec, D.

    2006-01-01

    FA2D/PARCS code package is used at Faculty of Electrical Engineering and Computing (FER), University of Zagreb, for static and dynamic reactor core analyses. It consists of two codes: FA2D and PARCS. FA2D is a multigroup two dimensional transport theory code for burn-up calculations based on collision probability method, developed at FER. It generates homogenised cross sections both of single pins and entire fuel assemblies. PARCS is an advanced nodal code developed at Purdue University for US NRC and it is based on neutron diffusion theory for three dimensional whole core static and dynamic calculations. It is modified at FER to enable internal 3D depletion calculation and usage of neutron cross section data in a format produced by FA2D and interface codes. The FA2D/PARCS code system has been validated on NPP Krsko operational data (Cycles 1 and 21). As we intend to use this code package for development of IRIS reactor loading patterns the first logical step was to validate the FA2D/PARCS code package on a set of IRIS benchmarks, starting from simple unit fuel cell, via fuel assembly, to full core benchmark. The IRIS 17x17 fuel with erbium burnable absorber was used in last full core benchmark. The results of modelling the IRIS full core benchmark using FA2D/PARCS code package have been compared with reference data showing the adequacy of FA2D/PARCS code package model for IRIS reactor core design.(author)

  16. Adaptive decoding of convolutional codes

    Science.gov (United States)

    Hueske, K.; Geldmacher, J.; Götze, J.

    2007-06-01

    Convolutional codes, which are frequently used as error correction codes in digital transmission systems, are generally decoded using the Viterbi Decoder. On the one hand the Viterbi Decoder is an optimum maximum likelihood decoder, i.e. the most probable transmitted code sequence is obtained. On the other hand the mathematical complexity of the algorithm only depends on the used code, not on the number of transmission errors. To reduce the complexity of the decoding process for good transmission conditions, an alternative syndrome based decoder is presented. The reduction of complexity is realized by two different approaches, the syndrome zero sequence deactivation and the path metric equalization. The two approaches enable an easy adaptation of the decoding complexity for different transmission conditions, which results in a trade-off between decoding complexity and error correction performance.

  17. A parallel code named NEPTUNE for 3D fully electromagnetic and pic simulations

    International Nuclear Information System (INIS)

    Dong Ye; Yang Wenyuan; Chen Jun; Zhao Qiang; Xia Fang; Ma Yan; Xiao Li; Sun Huifang; Chen Hong; Zhou Haijing; Mao Zeyao; Dong Zhiwei

    2010-01-01

    A parallel code named NEPTUNE for 3D fully electromagnetic and particle-in-cell (PIC) simulations is introduced, which could run on the Linux system with hundreds to thousand CPUs. NEPTUNE is suitable to simulate entire 3D HPM devices; many HPM devices are simulated and designed by using it. In NEPTUNE code, the electromagnetic fields are updated by using the finite-difference in time domain (FDTD) method of solving Maxwell equations and the particles are moved by using Buneman-Boris advance method of solving relativistic Newton-Lorentz equation. Electromagnetic fields and particles are coupled by using liner weighing interpolation PIC method, and the electric filed components are corrected by using Boris method of solve Poisson equation in order to ensure charge-conservation. NEPTUNE code could construct many complicated geometric structures, such as arbitrary axial-symmetric structures, plane transforming structures, slow-wave-structures, coupling holes, foils, and so on. The boundary conditions used in NEPTUNE code are introduced in brief, including perfectly electric conductor boundary, external wave boundary, and particle boundary. Finally, some typical HPM devices are simulated and test by using NEPTUNE code, including MILO, RBWO, VCO, and RKA. The simulation results are with correct and credible physical images, and the parallel efficiencies are also given. (authors)

  18. Purifying selection acts on coding and non-coding sequences of paralogous genes in Arabidopsis thaliana.

    Science.gov (United States)

    Hoffmann, Robert D; Palmgren, Michael

    2016-06-13

    Whole-genome duplications in the ancestors of many diverse species provided the genetic material for evolutionary novelty. Several models explain the retention of paralogous genes. However, how these models are reflected in the evolution of coding and non-coding sequences of paralogous genes is unknown. Here, we analyzed the coding and non-coding sequences of paralogous genes in Arabidopsis thaliana and compared these sequences with those of orthologous genes in Arabidopsis lyrata. Paralogs with lower expression than their duplicate had more nonsynonymous substitutions, were more likely to fractionate, and exhibited less similar expression patterns with their orthologs in the other species. Also, lower-expressed genes had greater tissue specificity. Orthologous conserved non-coding sequences in the promoters, introns, and 3' untranslated regions were less abundant at lower-expressed genes compared to their higher-expressed paralogs. A gene ontology (GO) term enrichment analysis showed that paralogs with similar expression levels were enriched in GO terms related to ribosomes, whereas paralogs with different expression levels were enriched in terms associated with stress responses. Loss of conserved non-coding sequences in one gene of a paralogous gene pair correlates with reduced expression levels that are more tissue specific. Together with increased mutation rates in the coding sequences, this suggests that similar forces of purifying selection act on coding and non-coding sequences. We propose that coding and non-coding sequences evolve concurrently following gene duplication.

  19. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  20. Pulsed electric field processing reduces the oxalate content of oca (Oxalis tuberosa) tubers while retaining starch grains and the general structural integrity of tubers.

    Science.gov (United States)

    Liu, Tingting; Burritt, David John; Eyres, Graham T; Oey, Indrawati

    2018-04-15

    The aims of this research were to investigate if pulsed electric field (PEF) treatments caused cellular/structural alterations in Oxalis tuberosa (oca) tubers and if PEF treatment could reduce tuber oxalate levels. Whole oca tubers were treated with PEF at different electric field strengths up to 1.2 kV/cm. PEF treatments above 0.5 kV/cm caused tubers to soften, but differences in the electrical properties of the tuber tissues led to an uneven PEF effect with the tuber inner cores softening more than the middle regions. Cell viability tests confirmed the unevenness of the PEF effect, however PEF caused no changes in overall tuber/tissue structure. Even at high electric field strengths the cell remained largely intact and most starch grains were retained within the cells. Despite the retention of starch, PEF treatment reduced tuber oxalate contents by almost 50% in some tissues and could potentially aid the development of low oxalate oca-based foods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Frankfurt Local Court: Decision of April 24, 1980 - legally binding - on the boycotting of electricity rate payment

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    With regard to payments due for electric energy supplied, electricity rate boycotters cannot derive the right fo refusal to pay from Art. 4 (1) of the Basic Law or from Sect. 242 of the German Civil code. Just a littel have electricity rate boycotters the right to withhold payments according to Sect. 273 of the German Civil Code. If electricity rate boycotters consistently withhold parts of the payments which are due, this refusal to pay rates will empower the electricity supply utility to cancel corresponding supply contracts without notice. This is also applicable if, in the individual case, it is a matter of small amounts. (orig.) [de

  2. Inhibition of xanthine oxidase reduces oxidative stress and improves skeletal muscle function in response to electrically stimulated isometric contractions in aged mice

    Science.gov (United States)

    Ryan, Michael J.; Jackson, Janna R.; Hao, Yanlei; Leonard, Stephen S.; Alway, Stephen E.

    2012-01-01

    Oxidative stress is a putative factor responsible for reducing function and increasing apoptotic signaling in skeletal muscle with aging. This study examined the contribution and functional significance of the xanthine oxidase enzyme as a potential source of oxidant production in aged skeletal muscle during repetitive in situ electrically stimulated isometric contractions. Xanthine oxidase activity was inhibited in young adult and aged mice via a subcutaneously placed time release (2.5 mg/day) allopurinol pellet, 7 days prior to the start of in situ electrically stimulated isometric contractions. Gastrocnemius muscles were electrically activated with 20 maximal contractions for three consecutive days. Xanthine oxidase activity was 65% greater in the gastrocnemius muscle of aged mice compared to young mice. Xanthine oxidase activity also increased after in situ electrically stimulated isometric contractions in muscles from both young (33%) and aged (28%) mice, relative to contralateral non-contracted muscles. Allopurinol attenuated the exercise-induced increase in oxidative stress, but it did not affect the elevated basal levels of oxidative stress that was associated with aging. In addition, inhibition of xanthine oxidase activity decreased caspase 3 activity, but it had no effect on other markers of mitochondrial associated apoptosis. Our results show that compared to control conditions, suppression of xanthine oxidase activity by allopurinol reduced xanthine oxidase activity, H2O2 levels, lipid peroxidation and caspase-3 activity, prevented the in situ electrically stimulated isometric contraction-induced loss of glutathione, prevented the increase of catalase and copper-zinc superoxide dismutase activities, and increased maximal isometric force in the plantar flexor muscles of aged mice after repetitive electrically evoked contractions. PMID:21530649

  3. Secure Coding for Safety I and C Systems on Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Y. M.; Park, H. S.; Kim, T. H.

    2015-01-01

    This paper addresses secure coding technologies which can reduce the software vulnerabilities and provides secure coding application guidelines for nuclear safety I and C systems. The use of digital equipment may improve their reliability and reduce maintenance costs. But, the design characteristics of nuclear I and C systems are becoming more complex and the possibility of cyber-attacks using software vulnerabilities has been increased. Software defects, bugs and logic flaws have been consistently the primary causes of software vulnerabilities which can introduce security vulnerabilities. In this study, we described a applying methods for secure coding which can reduce the software vulnerabilities. Software defects lists, countermeasures for each defect and coding rules can be applied properly depending on target system's condition. We expect that the results of this study can help developing the secure coding guidelines and significantly reducing or eliminating vulnerabilities in nuclear safety I and C software

  4. Secure Coding for Safety I and C Systems on Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. M.; Park, H. S. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, T. H. [Formal Works Inc., Seoul (Korea, Republic of)

    2015-10-15

    This paper addresses secure coding technologies which can reduce the software vulnerabilities and provides secure coding application guidelines for nuclear safety I and C systems. The use of digital equipment may improve their reliability and reduce maintenance costs. But, the design characteristics of nuclear I and C systems are becoming more complex and the possibility of cyber-attacks using software vulnerabilities has been increased. Software defects, bugs and logic flaws have been consistently the primary causes of software vulnerabilities which can introduce security vulnerabilities. In this study, we described a applying methods for secure coding which can reduce the software vulnerabilities. Software defects lists, countermeasures for each defect and coding rules can be applied properly depending on target system's condition. We expect that the results of this study can help developing the secure coding guidelines and significantly reducing or eliminating vulnerabilities in nuclear safety I and C software.

  5. Electricity consumption and electricity saving in the Swedish households

    Energy Technology Data Exchange (ETDEWEB)

    Bernstroem, B M; Eklund, Y; Sjoeberg, L

    1997-03-01

    The objective of the present study is to determine which factors influence electricity consumption behavior of Swedish households, the level of knowledge about electricity use and the willingness to pay for the use of electricity. In Sweden, as in many other developed countries, the need for electric power is constantly increasing. The major reason for this increase in electricity consumption is the lifestyle of a modern society. A feature in the nuclear power discussion is that the government in Sweden is having a hard time to establish how to phase-out all nuclear power plants by 2010. An additional major change in Swedish energy policy is the deregulation of the electricity market, which started in the beginning of 1996. There is an increased demand for strategies to save electricity among households. The results of this study stress the difficulties in reducing electricity consumption and to develop new electricity saving strategies in Sweden 125 refs, 6 figs, 21 tabs

  6. Multi-stage decoding of multi-level modulation codes

    Science.gov (United States)

    Lin, Shu; Kasami, Tadao; Costello, Daniel J., Jr.

    1991-01-01

    Various types of multi-stage decoding for multi-level modulation codes are investigated. It is shown that if the component codes of a multi-level modulation code and types of decoding at various stages are chosen properly, high spectral efficiency and large coding gain can be achieved with reduced decoding complexity. Particularly, it is shown that the difference in performance between the suboptimum multi-stage soft-decision maximum likelihood decoding of a modulation code and the single-stage optimum soft-decision decoding of the code is very small, only a fraction of dB loss in signal to noise ratio at a bit error rate (BER) of 10(exp -6).

  7. COSINE software development based on code generation technology

    International Nuclear Information System (INIS)

    Ren Hao; Mo Wentao; Liu Shuo; Zhao Guang

    2013-01-01

    The code generation technology can significantly improve the quality and productivity of software development and reduce software development risk. At present, the code generator is usually based on UML model-driven technology, which can not satisfy the development demand of nuclear power calculation software. The feature of scientific computing program was analyzed and the FORTRAN code generator (FCG) based on C# was developed in this paper. FCG can generate module variable definition FORTRAN code automatically according to input metadata. FCG also can generate memory allocation interface for dynamic variables as well as data access interface. FCG was applied to the core and system integrated engine for design and analysis (COSINE) software development. The result shows that FCG can greatly improve the development efficiency of nuclear power calculation software, and reduce the defect rate of software development. (authors)

  8. Annual report on compliance with the codes of good conduct and independence of electricity grid and natural gas network operators. November 2005

    International Nuclear Information System (INIS)

    2005-11-01

    In France, system operators belong to groups that also conduct business in the energy sector, in fields governed by competition rules. They could therefore be tempted to use their privileged position to their group's benefit, which would disadvantage end consumers. Non-discriminatory access to electricity and gas transmission and distribution networks is at the core of the market opening to competition approach implemented by the European Union since the end of the 1990's. EU and national enactments in force highlight two tools to ensure nondiscrimination: compliance programmes and independence of system operators with regard to their parent companies. Firstly, compliance programs contain measures taken to ensure that discrimination is completely excluded and that their application is subject to appropriate monitoring. Secondly, system operator independence plays a part in preventing discrimination against competitors with other business activities (generation, supply, etc.) within the same group. In application of these enactments, every electricity or natural gas transmission or distribution system operator serving more than 100,000 customers provided CRE, the Energy Regulatory Commission, with their annual reports on the application of their compliance programs. This document is CRE's November 2005 report about compliance programmes and independence of electricity and natural gas system operators. It has been prepared using the codes of good conduct and the annual reports supplied by network operators. CRE also launched a public consultation of the market players in October 2005 and listened to what the network operators had to say. Moreover, it carried out a certain number of checks on operators' practices

  9. Coded aperture optimization using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Martineau, A.; Rocchisani, J.M.; Moretti, J.L.

    2010-01-01

    Coded apertures using Uniformly Redundant Arrays (URA) have been unsuccessfully evaluated for two-dimensional and three-dimensional imaging in Nuclear Medicine. The images reconstructed from coded projections contain artifacts and suffer from poor spatial resolution in the longitudinal direction. We introduce a Maximum-Likelihood Expectation-Maximization (MLEM) algorithm for three-dimensional coded aperture imaging which uses a projection matrix calculated by Monte Carlo simulations. The aim of the algorithm is to reduce artifacts and improve the three-dimensional spatial resolution in the reconstructed images. Firstly, we present the validation of GATE (Geant4 Application for Emission Tomography) for Monte Carlo simulations of a coded mask installed on a clinical gamma camera. The coded mask modelling was validated by comparison between experimental and simulated data in terms of energy spectra, sensitivity and spatial resolution. In the second part of the study, we use the validated model to calculate the projection matrix with Monte Carlo simulations. A three-dimensional thyroid phantom study was performed to compare the performance of the three-dimensional MLEM reconstruction with conventional correlation method. The results indicate that the artifacts are reduced and three-dimensional spatial resolution is improved with the Monte Carlo-based MLEM reconstruction.

  10. Increasing electric vehicle policy efficiency and effectiveness by reducing mainstream market bias

    International Nuclear Information System (INIS)

    Green, Erin H.; Skerlos, Steven J.; Winebrake, James J.

    2014-01-01

    Plug-in electric vehicles (PEVs) provide an opportunity for reducing energy use and emissions in the transportation sector. Currently, a number of federal policies are in place to incentivize deployment of PEVs to mainstream consumers with demographics and vehicle attribute preferences most common to today's new vehicle purchasers. This article argues that policies intending to give PEVs a foothold in the market should not focus on mainstream consumers and should instead focus on niche markets—specifically carsharing and postal fleets—and early adopters including green consumers. Two arguments can be made in support of eliminating the mainstream market bias of current policies toward a policy of cultivating niche markets. The first is efficiency: so far PEV policies featuring a mainstream market bias have proven to be inefficient and costly. The second is effectiveness: it is becoming increasingly evident that PEV policies would be more effective in achieving potential societal benefits if they focused on early adopters and niche markets using such approaches as strategic niche management, accessible loans and financing, and appropriately targeted incentives. PEV policies focused on early adopters and niche markets would create complementary system effects that will lead to increased PEV market penetration and realization of intended societal benefits. - Highlights: • We argue that U.S. electric vehicle policies are inefficient and ineffective. • We introduce “mainstream consumer bias” as an explanation for policy deficiencies. • We propose an alternative policy agenda to address some of these policy problems. • Proposed policy options include strategic niche management, targeted R and D and incentives, and loans

  11. Sizing of the thermal and electrical systems for an FED bundle divertor design with MgO insulation

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The high-order dependence of toroidal ripple from a bundle divertor on the magnet shield thickness increases the desirability of a magnet technology with minimal shielding requirements. A jacketed conductor with MgO powder insulation has been used successfully in highly irradiated environments. Its properties and limitations are described. A thermal and electrical sizing code has been developed for magnet design with this technology. Two design examples for ETF and FED missions show reduced recirculating power from previously reported designs

  12. Battery-Powered Electric and Hybrid Electric Vehicle Projects to Reduce Greenhouse Gas Emissions: A Resource for Project Development

    Energy Technology Data Exchange (ETDEWEB)

    National Energy Technology Laboratory

    2002-07-31

    The transportation sector accounts for a large and growing share of global greenhouse gas (GHG) emissions. Worldwide, motor vehicles emit well over 900 million metric tons of carbon dioxide (CO2) each year, accounting for more than 15 percent of global fossil fuel-derived CO2 emissions.1 In the industrialized world alone, 20-25 percent of GHG emissions come from the transportation sector. The share of transport-related emissions is growing rapidly due to the continued increase in transportation activity.2 In 1950, there were only 70 million cars, trucks, and buses on the world’s roads. By 1994, there were about nine times that number, or 630 million vehicles. Since the early 1970s, the global fleet has been growing at a rate of 16 million vehicles per year. This expansion has been accompanied by a similar growth in fuel consumption.3 If this kind of linear growth continues, by the year 2025 there will be well over one billion vehicles on the world’s roads.4 In a response to the significant growth in transportation-related GHG emissions, governments and policy makers worldwide are considering methods to reverse this trend. However, due to the particular make-up of the transportation sector, regulating and reducing emissions from this sector poses a significant challenge. Unlike stationary fuel combustion, transportation-related emissions come from dispersed sources. Only a few point-source emitters, such as oil/natural gas wells, refineries, or compressor stations, contribute to emissions from the transportation sector. The majority of transport-related emissions come from the millions of vehicles traveling the world’s roads. As a result, successful GHG mitigation policies must find ways to target all of these small, non-point source emitters, either through regulatory means or through various incentive programs. To increase their effectiveness, policies to control emissions from the transportation sector often utilize indirect means to reduce emissions, such

  13. Stuttgart Local Court: Decision of February 15, 1980 - legally binding - on the boycotting of electricity rate payments

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    With regard to payments due for electric energy supplies, electricity rate payment boycotters have neither the right to withhold payments according to Sect. 273 of the German Civil Code, nor the right of refusal to pay rates with reference to provisions of the Basic Law. A declaratory action against electricity rate payment boycotters, aiming at the judgment that they have no right of refusal to pay and no right to withhold payment, if the energy supplied is - in whole or in part - generated by licenced nuclear power stations, or if the electricity supply utility has a share in nuclear power stations, takes the conditions applicable to the admissibility of Sect. 256 (1) of the Code of Civil Procedure into account and is founded, too. To stay proceedings between the electricity supply utility and on the payment of electricity rates withheld electricity rate payment boycotters according to Sect. 148 of the Code of Civil Procedure - because of proceedings pending at administrative courts on the legality of operating licences issued for nuclear power stations - must not be considered since decisions made by administrative courts are irrelevant in this respect. (orig.) [de

  14. Anomalous electrical signals associated with microbial activity: Results from Iron and Nitrate-Reducing Columns

    Science.gov (United States)

    Aaron, R. B.; Zheng, Q.; Flynn, P.; Singha, K.; Brantley, S.

    2008-12-01

    Three flow-through columns outfitted with Ag/AgCl electrodes were constructed to test the effects of different microbial processes on the geophysical measurements of self potential (SP), bulk electrical conductivity (σ b), and induced polarization (IP). The columns were filled with sieved, Fe-bearing subsurface sediment from the Delmarva Peninsula near Oyster, VA, inoculated (9:1 ratio) with a freshly-collected, shallow subsurface sediment from a wetland floodplain (Dorn Creek) near Madison, WI. Each of the columns was fed anoxic and sterile PIPES buffered artificial groundwater (PBAGW) containing different concentrations of acetate and nitrate. The medium fed to Column 1 (nitrate-reducing) was amended with 100 μM acetate and 2 mM nitrate. Column 2 (iron-reducing) was run with PBAGW containing 1.0 mM acetate and 0 mM nitrate. Column 3 (alternating redox state) was operated under conditions designed to alternately stimulate nitrate-reducing and iron-reducing populations to provide conditions, i.e., the presence of both nitrate and microbially-produced Fe(II), that would allow growth of nitrate-dependent Fe(II)-oxidizing populations. We operated Column 3 with a cycling strategy of 14-18 days of high C medium (1 mM acetate and 100 μ M nitrate) followed by 14-18 days of low C medium (100 μ M acetate and 2 mM nitrate). Effluent chemistry (NO3-, NO2-, NH4+, acetate, and Fe2+) was sampled daily for four months so as to be concurrent with the electrical measurements. We observed chemical evidence of iron reduction (dissolved [Fe(II)] = 0.2mM) in the effluent from the iron reduction and alternating redox columns. Chemical depletion of NO3- ([NO3-] ranged from 1 to 0.02mM), the production of NO2-, and possible production of NH4+ (0.2 mM) was observed in the nitrate reducing column as well as the alternating redox column. All three columns displayed loss of acetate as microbial activity progressed. σ b remained constant in the alternating redox column (~0.15 S

  15. Impacts of Model Building Energy Codes

    Energy Technology Data Exchange (ETDEWEB)

    Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sivaraman, Deepak [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elliott, Douglas B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bartlett, Rosemarie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO2 emissions at the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.

  16. Performance analysis of multiple interference suppression over asynchronous/synchronous optical code-division multiple-access system based on complementary/prime/shifted coding scheme

    Science.gov (United States)

    Nieh, Ta-Chun; Yang, Chao-Chin; Huang, Jen-Fa

    2011-08-01

    A complete complementary/prime/shifted prime (CPS) code family for the optical code-division multiple-access (OCDMA) system is proposed. Based on the ability of complete complementary (CC) code, the multiple-access interference (MAI) can be suppressed and eliminated via spectral amplitude coding (SAC) OCDMA system under asynchronous/synchronous transmission. By utilizing the shifted prime (SP) code in the SAC scheme, the hardware implementation of encoder/decoder can be simplified with a reduced number of optical components, such as arrayed waveguide grating (AWG) and fiber Bragg grating (FBG). This system has a superior performance as compared to previous bipolar-bipolar coding OCDMA systems.

  17. Adaptive decoding of convolutional codes

    Directory of Open Access Journals (Sweden)

    K. Hueske

    2007-06-01

    Full Text Available Convolutional codes, which are frequently used as error correction codes in digital transmission systems, are generally decoded using the Viterbi Decoder. On the one hand the Viterbi Decoder is an optimum maximum likelihood decoder, i.e. the most probable transmitted code sequence is obtained. On the other hand the mathematical complexity of the algorithm only depends on the used code, not on the number of transmission errors. To reduce the complexity of the decoding process for good transmission conditions, an alternative syndrome based decoder is presented. The reduction of complexity is realized by two different approaches, the syndrome zero sequence deactivation and the path metric equalization. The two approaches enable an easy adaptation of the decoding complexity for different transmission conditions, which results in a trade-off between decoding complexity and error correction performance.

  18. Cooling the Campus: Experiences from a Pilot Study to Reduce Electricity Use at Tufts University, USA, Using Social Marketing Methods

    Science.gov (United States)

    Marcell, Kristin; Agyeman, Julian; Rappaport, Ann

    2004-01-01

    A community-based social marketing (CBSM) campaign to reduce student electricity use and greenhouse gas emissions was undertaken at Tufts University in Medford, Massachusetts. Social marketing methods follow a commercial marketing model and involve market research into the planning, pricing, communication, distribution, and evaluation of methods…

  19. Gap conductance model validation in the TASS/SMR-S code

    International Nuclear Information System (INIS)

    Ahn, Sang-Jun; Yang, Soo-Hyung; Chung, Young-Jong; Bae, Kyoo-Hwan; Lee, Won-Jae

    2011-01-01

    An advanced integral pressurized water reactor, SMART (System-Integrated Modular Advanced ReacTor) has been developed by KAERI (Korea Atomic Energy Research and Institute). The purposes of the SMART are sea water desalination and an electricity generation. For the safety evaluation and performance analysis of the SMART, TASS/SMR-S (Transient And Setpoint Simulation/System-integrated Modular Reactor) code, has been developed. In this paper, the gap conductance model for the calculation of gap conductance has been validated by using another system code, MARS code, and experimental results. In the validation, the behaviors of fuel temperature and gap width are selected as the major parameters. According to the evaluation results, the TASS/SMR-S code predicts well the behaviors of fuel temperatures and gap width variation, compared to the MARS calculation results and experimental data. (author)

  20. Wind power within European grid codes: Evolution, status and outlook

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Flynn, Damian; Gomez-Lazaro, Emilio

    2018-01-01

    Grid codes are technical specifications that define the requirements for any facility connected to electricity grids. Wind power plants are increasingly facing system stability support requirements similar to conventional power stations, which is to some extent unavoidable, as the share of wind...... power in the generation mix is growing. The adaptation process of grid codes for wind power plants is not yet complete, and grid codes are expected to evolve further in the future. ENTSO-E is the umbrella organization for European TSOs, seen by many as a leader in terms of requirements sophistication...... is largely based on the definitions and provisions set out by ENTSO-E. The main European grid code requirements are outlined here, including also HVDC connections and DC-connected power park modules. The focus is on requirements that are considered particularly relevant for large wind power plants...

  1. BLAKE - A Thermodynamics Code Based on TIGER: Users' Guide to the Revised Program

    National Research Council Canada - National Science Library

    Freedman, Eli

    1998-01-01

    .... This code, which was derived from the original version of SRI's TIGER program, is intended primarily for making calculations on the combustion products from conventional military and electrically...

  2. Global and kinetic MHD simulation by the Gpic-MHD code

    International Nuclear Information System (INIS)

    Naitou, Hiroshi; Yamada, Yusuke; Kajiwara, Kenji; Lee, Wei-li; Tokuda, Shinji; Yagi, Masatoshi

    2011-01-01

    In order to implement large-scale and high-beta tokamak simulation, a new algorithm of the electromagnetic gyrokinetic PIC (particle-in-cell) code was proposed and installed on the Gpic-MHD code [Gyrokinetic PIC code for magnetohydrodynamic (MHD) simulation]. In the new algorithm, the vortex equation and the generalized ohm's law along the magnetic field are derived from the basic equations of the gyrokinetic Vlasov, Poisson, and Ampere system and are used to describe the spatio-temporal evolution of the field quantities of the electrostatic potential φ and the longitudinal component of the vector potential A z . Particle information is mainly used to estimate second order moments in the generalized ohm's law. Because the lower order moments of the charge density and the longitudinal current density are not used explicitly to determine φ and A z , the numerical noise induced by the discreteness of particle quantities reduces drastically. Another advantage of the algorithm is that the longitudinal induced electric field, E Tz =-∂A z /∂t, is explicitly estimated by the generalized ohm's law and used in the equations of motion. The particle velocities along the magnetic field are used (v z -formulation) instead of generalized momentums (p z -formulation), hence there is no problem of 'cancellation', which appear when estimating A z from the Ampere's law in the p z -formulation. The successful simulation of the collisionless internal kink mode by new Gpic-MHD with the realistic values of the large-scale and high-beta, revealed the usefulness of the new algorithm. (author)

  3. Improvement of system code importing evaluation of Life Cycle Analysis of tokamak fusion power reactors

    International Nuclear Information System (INIS)

    Kobori, Hikaru; Kasada, Ryuta; Hiwatari, Ryoji; Konishi, Satoshi

    2016-01-01

    Highlights: • We incorporated the Life Cycle Analysis (LCA) of tokamak type DEMO reactor and following commercial reactors as an extension of a system code. • We calculated CO_2 emissions from reactor construction, operation and decommissioning that is considered as a major environmental cost. • We found that the objective of conceptual design of the tokamak fusion power reactor is moved by changing evaluation index. • The tokamak fusion reactor can reduce CO_2 emissions in the life cycle effectively by reduction of the amount involved in the replacement of internal components. • The tokamak fusion reactor achieves under 0.174$/kWh electricity cost, the tokamak fusion reactor is contestable with 1500 degrees-class LNG-fired combined cycle power plant. - Abstract: This study incorporate the Life Cycle Analysis (LCA) of tokamak type DEMO reactor and following commercial reactors as an extension of a system code to calculate CO_2 emissions from reactor construction, operation and decommissioning that is considered as a major environmental cost. Competitiveness of tokamak fusion power reactors is expected to be evaluated by the cost and environmental impact represented by the CO_2 emissions, compared with present and future power generating systems such as fossil, nuclear and renewables. Result indicated that (1) The objective of conceptual design of the tokamak fusion power reactor is moved by changing evaluation index. (2) The tokamak fusion reactor can reduce CO_2 emissions in the life cycle effectively by reduction of the amount involved in the replacement of internal components. (3) The tokamak fusion reactor achieves under 0.174$/kWh electricity cost, the tokamak fusion reactor is contestable with 1500 degrees-class LNG-fired combined cycle power plant.

  4. Improvement of system code importing evaluation of Life Cycle Analysis of tokamak fusion power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kobori, Hikaru [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Kasada, Ryuta, E-mail: r-kasada@iae.kyoto-u.ac.jp [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Hiwatari, Ryoji [Central Research Institute of Electric Power Industry, Tokyo (Japan); Konishi, Satoshi [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan)

    2016-11-01

    Highlights: • We incorporated the Life Cycle Analysis (LCA) of tokamak type DEMO reactor and following commercial reactors as an extension of a system code. • We calculated CO{sub 2} emissions from reactor construction, operation and decommissioning that is considered as a major environmental cost. • We found that the objective of conceptual design of the tokamak fusion power reactor is moved by changing evaluation index. • The tokamak fusion reactor can reduce CO{sub 2} emissions in the life cycle effectively by reduction of the amount involved in the replacement of internal components. • The tokamak fusion reactor achieves under 0.174$/kWh electricity cost, the tokamak fusion reactor is contestable with 1500 degrees-class LNG-fired combined cycle power plant. - Abstract: This study incorporate the Life Cycle Analysis (LCA) of tokamak type DEMO reactor and following commercial reactors as an extension of a system code to calculate CO{sub 2} emissions from reactor construction, operation and decommissioning that is considered as a major environmental cost. Competitiveness of tokamak fusion power reactors is expected to be evaluated by the cost and environmental impact represented by the CO{sub 2} emissions, compared with present and future power generating systems such as fossil, nuclear and renewables. Result indicated that (1) The objective of conceptual design of the tokamak fusion power reactor is moved by changing evaluation index. (2) The tokamak fusion reactor can reduce CO{sub 2} emissions in the life cycle effectively by reduction of the amount involved in the replacement of internal components. (3) The tokamak fusion reactor achieves under 0.174$/kWh electricity cost, the tokamak fusion reactor is contestable with 1500 degrees-class LNG-fired combined cycle power plant.

  5. Electric cars as buffers in an electricity network

    NARCIS (Netherlands)

    Vleugel, J.M.; Bal, Frans; Brebbia, Carlos; Miralles i Garcia, Jose

    2016-01-01

    Producing more electricity from alternative sources may help to reach four goals: reduce CO2- and other emissions, compensate for depleting resources, reduce political dependency and replace an ageing and inefficient infrastructure. Billions of Euros have to be spent in ‘grey’ or ‘green technology

  6. Update on the supplier certification and the status of the retail electric market

    International Nuclear Information System (INIS)

    Dingwall, B.A.

    1999-01-01

    The issue of rulemaking and code of conduct for energy marketers in Ontario is discussed. As the Ontario government is deregulating the electric power industry, it seems as though it is creating more rules, regulations and codes of conduct than in the previous regulated market. This paper presents an overview of the existing Consumer Protection Legislation, including the Consumer Protection Act, the Business Practices Act, and the Competition Act. Some of the major issues facing the electric retail market are reviewed. These are: (1) alternate contracting methods, (2) rebundling other products and services, (3) green power disclosure, (4) standard supply, (5) unbundling of competitive functions from monopoly providers, (6) exemptions for different utilities, and (7) disconnection of service. Text of the Ontario Energy Board's papers entitled 'Code of conduct for gas marketers', and the 'Code of conduct for energy marketers' are attached

  7. A Method for Improving the Progressive Image Coding Algorithms

    Directory of Open Access Journals (Sweden)

    Ovidiu COSMA

    2014-12-01

    Full Text Available This article presents a method for increasing the performance of the progressive coding algorithms for the subbands of images, by representing the coefficients with a code that reduces the truncation error.

  8. Scoping calculations of power sources for nuclear electric propulsion

    International Nuclear Information System (INIS)

    Difilippo, F.C.

    1994-05-01

    This technical memorandum describes models and calculational procedures to fully characterize the nuclear island of power sources for nuclear electric propulsion. Two computer codes were written: one for the gas-cooled NERVA derivative reactor and the other for liquid metal-cooled fuel pin reactors. These codes are going to be interfaced by NASA with the balance of plant in order to making scoping calculations for mission analysis

  9. European Model Code of safe practice in the storage and handling of petroleum products. Part I. Operations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    This safe practice code was prepared by a working group consisting of experts from 10 Western European countries. It consists of short guidelines and technical advice on general precautions, injuries and medical services, permits to work, fire prevention and fighting, jetties, pipework, storage tanks, static electricity, electrical equipment, road vehicles, tank cars, handling of bitumen products, liquefied petroleum gases, packed products and training of personnel. The code is supplemented by 10 appendices, including a suggested syllabus for a 2-day course on fire prevention and emergency action for managers of oil installations.

  10. Computer-assisted Particle-in-Cell code development

    International Nuclear Information System (INIS)

    Kawata, S.; Boonmee, C.; Teramoto, T.; Drska, L.; Limpouch, J.; Liska, R.; Sinor, M.

    1997-12-01

    This report presents a new approach for an electromagnetic Particle-in-Cell (PIC) code development by a computer: in general PIC codes have a common structure, and consist of a particle pusher, a field solver, charge and current density collections, and a field interpolation. Because of the common feature, the main part of the PIC code can be mechanically developed on a computer. In this report we use the packages FIDE and GENTRAN of the REDUCE computer algebra system for discretizations of field equations and a particle equation, and for an automatic generation of Fortran codes. The approach proposed is successfully applied to the development of 1.5-dimensional PIC code. By using the generated PIC code the Weibel instability in a plasma is simulated. The obtained growth rate agrees well with the theoretical value. (author)

  11. Novel MSVPWM to reduce the inductor current ripple for Z-source inverter in electric vehicle applications.

    Science.gov (United States)

    Zhang, Qianfan; Dong, Shuai; Xue, Ping; Zhou, Chaowei; Cheng, ShuKang

    2014-01-01

    A novel modified space vector pulse width modulation (MSVPWM) strategy for Z-Source inverter is presented. By rearranging the position of shoot-through states, the frequency of inductor current ripple is kept constant. Compared with existing MSVPWM strategies, the proposed approach can reduce the maximum inductor current ripple. So the volume of Z-source network inductor can be designed smaller, which brings the beneficial effect on the miniaturization of the electric vehicle controller. Theoretical findings in the novel MSVPWM for Z-Source inverter have been verified by experiment results.

  12. Energy-Efficient Cluster Based Routing Protocol in Mobile Ad Hoc Networks Using Network Coding

    Directory of Open Access Journals (Sweden)

    Srinivas Kanakala

    2014-01-01

    Full Text Available In mobile ad hoc networks, all nodes are energy constrained. In such situations, it is important to reduce energy consumption. In this paper, we consider the issues of energy efficient communication in MANETs using network coding. Network coding is an effective method to improve the performance of wireless networks. COPE protocol implements network coding concept to reduce number of transmissions by mixing the packets at intermediate nodes. We incorporate COPE into cluster based routing protocol to further reduce the energy consumption. The proposed energy-efficient coding-aware cluster based routing protocol (ECCRP scheme applies network coding at cluster heads to reduce number of transmissions. We also modify the queue management procedure of COPE protocol to further improve coding opportunities. We also use an energy efficient scheme while selecting the cluster head. It helps to increase the life time of the network. We evaluate the performance of proposed energy efficient cluster based protocol using simulation. Simulation results show that the proposed ECCRP algorithm reduces energy consumption and increases life time of the network.

  13. Noise Residual Learning for Noise Modeling in Distributed Video Coding

    DEFF Research Database (Denmark)

    Luong, Huynh Van; Forchhammer, Søren

    2012-01-01

    Distributed video coding (DVC) is a coding paradigm which exploits the source statistics at the decoder side to reduce the complexity at the encoder. The noise model is one of the inherently difficult challenges in DVC. This paper considers Transform Domain Wyner-Ziv (TDWZ) coding and proposes...

  14. Renewable Energy and Energy Efficiency Technologies in Residential Building Codes: June 15, 1998 to September 15, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Wortman, D.; Echo-Hawk, L.

    2005-02-01

    This report is an attempt to describe the building code requirements and impediments to the application of EE and RE technologies in residential buildings. Several modern model building codes were reviewed. These are representative of the codes that will be adopted by most locations in the coming years. The codes reviewed for this report include: International Residential Code, First Draft, April 1998; International Energy Conservation Code, 1998; International Mechanical Code, 1998; International Plumbing Code, 1997; International Fuel Gas Code, 1997; National Electrical Code, 1996. These codes were reviewed as to their application to (1) PV systems in buildings and building-integrated PV systems and (2) active solar domestic hot water and space-heating systems. A discussion of general code issues that impact these technologies is also included. Examples of this are solar access and sustainability.

  15. Fast H.264/AVC FRExt intra coding using belief propagation.

    Science.gov (United States)

    Milani, Simone

    2011-01-01

    In the H.264/AVC FRExt coder, the coding performance of Intra coding significantly overcomes the previous still image coding standards, like JPEG2000, thanks to a massive use of spatial prediction. Unfortunately, the adoption of an extensive set of predictors induces a significant increase of the computational complexity required by the rate-distortion optimization routine. The paper presents a complexity reduction strategy that aims at reducing the computational load of the Intra coding with a small loss in the compression performance. The proposed algorithm relies on selecting a reduced set of prediction modes according to their probabilities, which are estimated adopting a belief-propagation procedure. Experimental results show that the proposed method permits saving up to 60 % of the coding time required by an exhaustive rate-distortion optimization method with a negligible loss in performance. Moreover, it permits an accurate control of the computational complexity unlike other methods where the computational complexity depends upon the coded sequence.

  16. Improved side information generation for distributed video coding

    DEFF Research Database (Denmark)

    Huang, Xin; Forchhammer, Søren

    2008-01-01

    As a new coding paradigm, distributed video coding (DVC) deals with lossy source coding using side information to exploit the statistics at the decoder to reduce computational demands at the encoder. The performance of DVC highly depends on the quality of side information. With a better side...... information generation method, fewer bits will be requested from the encoder and more reliable decoded frames will be obtained. In this paper, a side information generation method is introduced to further improve the rate-distortion (RD) performance of transform domain distributed video coding. This algorithm...

  17. Fast neutron fluence evaluation of the smart reactor pressure vessel by using the GEOSHIELD code

    International Nuclear Information System (INIS)

    Kim, K.Y.; Kim, K.S.; Kim, H.Y.; Lee, C.C.; Zee, S.Q.

    2007-01-01

    In Korea, the design of an advanced integral reactor system called SMART has been developed by KAERI to supply energy for seawater desalination as well as an electricity generation. A fast neutron fluence distribution at the SMART reactor pressure vessel was evaluated to confirm the integrity of the vessel by using the GEOSHIELD code. The GEOSHIELD code was developed by KAERI in order to prepare an input list including a geometry modeling of the DORT code and to process results from the DORT code output list. Results by a GEOSHIELD code processing and by a manual processing of the DORT show a good agreement. (author)

  18. Electrical Components Library for HAWC2

    DEFF Research Database (Denmark)

    Cutululis, Nicolaos A.; Larsen, Torben J.; Sørensen, Poul

    and Aalborg University. In this project, the focus is on the development of a simulation platform for wind turbine systems using different simulation tools. This report presents the electric component library developed for use in the aeroelastic code HAWC2. The developed library includes both steady state...... was developed. The model includes the dynamics of the rotor fluxes. The model is suitable for a more detailed investigation of the mechanical - electrical interaction, both under normal and fault operation. For the variable speed wind turbine, a steadystate model, typically used in aeroelastic design...

  19. The linear and nonlinear response of infinite periodic systems to static and/or dynamic electric fields. Implementation in CRYSTAL code

    Energy Technology Data Exchange (ETDEWEB)

    Kirtman, Bernard [Department of Chemistry and Biochemistry, University of California, Santa Barbara, California 93106 (United States); Springborg, Michael [Physical and Theoretical Chemistry, University of Saarland, 66123 Saarbrücken (Germany); Rérat, Michel [Equipe de Chimie Physique, IPREM UMR5254, Université de Pau et des Pays de l' Adour, 64000 Pau (France); Ferrero, Mauro; Lacivita, Valentina; Dovesi, Roberto [Departimeno di Chimica, IFM, Università di Torino and NIS - Nanostructure Interfaces and Surfaces - Centre of Excellence, Via P. Giuria 7, 10125 Torino (Italy); Orlando, Roberto [Departimento di Scienze e Tecnologie Avanzati, Università del Piemonte Orientale, Viale T. Michel 11, 15121 Alessandria (Italy)

    2015-01-22

    An implementation of the vector potential approach (VPA) for treating the response of infinite periodic systems to static and dynamic electric fields has been initiated within the CRYSTAL code. The VPA method is based on the solution of a time-dependent Hartree-Fock or Kohn-Sham equation for the crystal orbitals wherein the usual scalar potential, that describes interaction with the field, is replaced by the vector potential. This equation may be solved either by perturbation theory or by finite field methods. With some modification all the computational procedures of molecular ab initio quantum chemistry can be adapted for periodic systems. Accessible properties include the linear and nonlinear responses of both the nuclei and the electrons. The programming of static field pure electronic (hyper)polarizabilities has been successfully tested. Dynamic electronic (hyper)polarizabilities, as well as infrared and Raman intensities, are in progress while the addition of finite fields for calculation of vibrational (hyper)polarizabilities, through nuclear relaxation procedures, will begin shortly.

  20. An implicit Smooth Particle Hydrodynamic code

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, Charles E. [Univ. of New Mexico, Albuquerque, NM (United States)

    2000-05-01

    An implicit version of the Smooth Particle Hydrodynamic (SPH) code SPHINX has been written and is working. In conjunction with the SPHINX code the new implicit code models fluids and solids under a wide range of conditions. SPH codes are Lagrangian, meshless and use particles to model the fluids and solids. The implicit code makes use of the Krylov iterative techniques for solving large linear-systems and a Newton-Raphson method for non-linear corrections. It uses numerical derivatives to construct the Jacobian matrix. It uses sparse techniques to save on memory storage and to reduce the amount of computation. It is believed that this is the first implicit SPH code to use Newton-Krylov techniques, and is also the first implicit SPH code to model solids. A description of SPH and the techniques used in the implicit code are presented. Then, the results of a number of tests cases are discussed, which include a shock tube problem, a Rayleigh-Taylor problem, a breaking dam problem, and a single jet of gas problem. The results are shown to be in very good agreement with analytic solutions, experimental results, and the explicit SPHINX code. In the case of the single jet of gas case it has been demonstrated that the implicit code can do a problem in much shorter time than the explicit code. The problem was, however, very unphysical, but it does demonstrate the potential of the implicit code. It is a first step toward a useful implicit SPH code.

  1. PEAK-TO-AVERAGE POWER RATIO REDUCTION USING CODING AND HYBRID TECHNIQUES FOR OFDM SYSTEM

    OpenAIRE

    Bahubali K. Shiragapur; Uday Wali

    2016-01-01

    In this article, the research work investigated is based on an error correction coding techniques are used to reduce the undesirable Peak-to-Average Power Ratio (PAPR) quantity. The Golay Code (24, 12), Reed-Muller code (16, 11), Hamming code (7, 4) and Hybrid technique (Combination of Signal Scrambling and Signal Distortion) proposed by us are used as proposed coding techniques, the simulation results shows that performance of Hybrid technique, reduces PAPR significantly as compared to Conve...

  2. Sustainable Federal Fleets: Deploying Electric Vehicles and Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) helps federal agencies reduce petroleum consumption and increase alternative fuel use through its resources for Sustainable Federal Fleets. To assist agencies with the transition to plug-in electric vehicles (PEVs), including battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), FEMP offers technical guidance on electric vehicle supply equipment (EVSE) installations and site-specific planning through partnerships with the National Renewable Energy Laboratory's (NREL's) EVSE Tiger Teams.

  3. Assessing incentive contracts for reducing residential electricity consumption: new experimental methods for new results

    International Nuclear Information System (INIS)

    Frachet, Laure

    2013-01-01

    Facing economic, political and environmental stakes, electricity providers are nowadays developing incentive tools, in order to reduce consumer's demand, particularly during peak demand periods. For residential customers, these tools can be tariffs (dynamic pricing of time-of-use tariffs), or informative devices or services (feedbacks on historical or real-time consumption, given on various media). They might go along with automation systems that can help cutting of some electric devices when needed. In order to evaluate the capacity of these settings among their customers, electricity utilities are developing quite a few studies, which are mainly field experiment often called pilots. During these pilots, demand response tools are implemented on a population sample. These long and expensive studies lid to quantitative and qualitative analysis. We have compiled about 40 of them and extract from this survey some generalizable teachings. We have shown what these results were and highlighted pilot programs' methodological limits. In order to propose a substitute to these heavy experimentations, we assessed the capacity or experimental economics. This relatively new discipline's objective is to evaluation the efficiency of institutions, like markets, but also to study what animate economic agents' behaviour, e.g. preferences, beliefs, cognitive biases, willingness to pay... We were also able to elaborate an experimental protocol dedicated to the evaluation of some demand response contracts' acceptability. The results collected during 14 experimental sessions gave us some innovative clues and insight on these contracts acceptability. But, beyond these results, we have demonstrated that even if experimental economics can't obviously be a substitute for field experiments, it can represent an interesting exploratory methodology. To sum up the experimental economics can take part of residential customers' behaviour understanding, performing

  4. Electrical stimulation reduces smokers' craving by modulating the coupling between dorsal lateral prefrontal cortex and parahippocampal gyrus.

    Science.gov (United States)

    Yang, Li-Zhuang; Shi, Bin; Li, Hai; Zhang, Wei; Liu, Ying; Wang, Hongzhi; Zhou, Yanfei; Wang, Ying; Lv, Wanwan; Ji, Xuebing; Hudak, Justin; Zhou, Yifeng; Fallgatter, Andreas J; Zhang, Xiaochu

    2017-08-01

    Applying electrical stimulation over the prefrontal cortex can help nicotine dependents reduce cigarette craving. However, the underlying mechanism remains ambiguous. This study investigates this issue with functional magnetic resonance imaging. Thirty-two male chronic smokers received real and sham stimulation over dorsal lateral prefrontal cortex (DLPFC) separated by 1 week. The neuroimaging data of the resting state, the smoking cue-reactivity task and the emotion task after stimulation were collected. The craving across the cue-reactivity task was diminished during real stimulation as compared with sham stimulation. The whole-brain analysis on the cue-reactivity task revealed a significant interaction between the stimulation condition (real vs sham) and the cue type (smoking vs neutral) in the left superior frontal gyrus and the left middle frontal gyrus. The functional connectivity between the left DLPFC and the right parahippocampal gyrus, as revealed by both psychophysical interaction analysis and the resting state functional connectivity, is altered by electrical stimulation. Moreover, the craving change across the real and sham condition is predicted by alteration of functional connectivity revealed by psychophysical interaction analysis. The local and long-distance coupling, altered by the electrical stimulation, might be the underlying neural mechanism of craving regulation. © The Author (2017). Published by Oxford University Press.

  5. Guidelines for gloveboxes. Section 5.14: Electrical

    International Nuclear Information System (INIS)

    Tollner, R.L.

    1995-07-01

    This is the electric portion of the design guidelines for gloveboxes developed by the American Glovebox Society. The topics include applicable codes/industry standards, penetrations/feedthroughs, wireways, junction boxes, receptacles, derating factors, conductors, conductor insulation and grounding. References for the guidelines are provided

  6. Pretest aerosol code comparisons for LWR aerosol containment tests LA1 and LA2

    International Nuclear Information System (INIS)

    Wright, A.L.; Wilson, J.H.; Arwood, P.C.

    1986-01-01

    The Light-Water-Reactor (LWR) Aerosol Containment Experiments (LACE) are being performed in Richland, Washington, at the Hanford Engineering Development Laboratory (HEDL) under the leadership of an international project board and the Electric Power Research Institute. These tests have two objectives: (1) to investigate, at large scale, the inherent aerosol retention behavior in LWR containments under simulated severe accident conditions, and (2) to provide an experimental data base for validating aerosol behavior and thermal-hydraulic computer codes. Aerosol computer-code comparison activities are being coordinated at the Oak Ridge National Laboratory. For each of the six LACE tests, ''pretest'' calculations (for code-to-code comparisons) and ''posttest'' calculations (for code-to-test data comparisons) are being performed. The overall goals of the comparison effort are (1) to provide code users with experience in applying their codes to LWR accident-sequence conditions and (2) to evaluate and improve the code models

  7. Electricity and Sustainability

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    This invited presentation first deals with the potentials and environmantal advantages of reducing electricity demand. The policies for implementing these savings are dicussed and proposal for future strategies are suggested. The mephasis is on the conflicts between a free European trade with ele......This invited presentation first deals with the potentials and environmantal advantages of reducing electricity demand. The policies for implementing these savings are dicussed and proposal for future strategies are suggested. The mephasis is on the conflicts between a free European trade...

  8. Acceleration of a Monte Carlo radiation transport code

    International Nuclear Information System (INIS)

    Hochstedler, R.D.; Smith, L.M.

    1996-01-01

    Execution time for the Integrated TIGER Series (ITS) Monte Carlo radiation transport code has been reduced by careful re-coding of computationally intensive subroutines. Three test cases for the TIGER (1-D slab geometry), CYLTRAN (2-D cylindrical geometry), and ACCEPT (3-D arbitrary geometry) codes were identified and used to benchmark and profile program execution. Based upon these results, sixteen top time-consuming subroutines were examined and nine of them modified to accelerate computations with equivalent numerical output to the original. The results obtained via this study indicate that speedup factors of 1.90 for the TIGER code, 1.67 for the CYLTRAN code, and 1.11 for the ACCEPT code are achievable. copyright 1996 American Institute of Physics

  9. Electric transmission technology

    International Nuclear Information System (INIS)

    Shah, K.R.

    1990-01-01

    Electric transmission technology has matured and can transmit bulk power more reliably and economically than the technology 10 years ago.In 1882, Marcel Depres transmitted 15 kW electric power at 2 kV, using a constant direct current; present transmission voltages have risen to ± 600 kV direct current (DC) and 765 kV alternating current (AC), and it is now possible to transmit bulk electric power at voltages as high as ± 1000 kV DC and 1500 kV AC. Affordable computer systems are now available to optimize transmission reliably. New materials have reduced the bulk of insulation for lines and equipment. New conducting materials and configurations have reduced losses in transmission. Advances in line structures and conductor motion, understanding of flashover characteristics of insulators and air-gaps and electrical performance of lines have resulted in more compact urban transmission lines. (author). 15 refs., 7 tabs., 11 figs

  10. Development of a multi-grid FDTD code for three-dimensional simulation of large microwave sintering experiments

    Energy Technology Data Exchange (ETDEWEB)

    White, M.J.; Iskander, M.F. [Univ. of Utah, Salt Lake City, UT (United States). Electrical Engineering Dept.; Kimrey, H.D. [Oak Ridge National Lab., TN (United States)

    1996-12-31

    The Finite-Difference Time-Domain (FDTD) code available at the University of Utah has been used to simulate sintering of ceramics in single and multimode cavities, and many useful results have been reported in literature. More detailed and accurate results, specifically around and including the ceramic sample, are often desired to help evaluate the adequacy of the heating procedure. In electrically large multimode cavities, however, computer memory requirements limit the number of the mathematical cells, and the desired resolution is impractical to achieve due to limited computer resources. Therefore, an FDTD algorithm which incorporates multiple-grid regions with variable-grid sizes is required to adequately perform the desired simulations. In this paper the authors describe the development of a three-dimensional multi-grid FDTD code to help focus a large number of cells around the desired region. Test geometries were solved using a uniform-grid and the developed multi-grid code to help validate the results from the developed code. Results from these comparisons, as well as the results of comparisons between the developed FDTD code and other available variable-grid codes are presented. In addition, results from the simulation of realistic microwave sintering experiments showed improved resolution in critical sites inside the three-dimensional sintering cavity. With the validation of the FDTD code, simulations were performed for electrically large, multimode, microwave sintering cavities to fully demonstrate the advantages of the developed multi-grid FDTD code.

  11. VFDs: Are They Electrical Parasites?

    Science.gov (United States)

    Frank, Ned

    2013-01-01

    Variable Frequency Drives (VFDs) are electronic speed controllers used mainly to modulate and reduce the overall speed and power consumption of an electrical motor. They can be used as soft starters for equipment that has a large rotational mass, thus reducing belt ware and large electrical peaks when starting large pieces of equipment. VFDs have…

  12. From concatenated codes to graph codes

    DEFF Research Database (Denmark)

    Justesen, Jørn; Høholdt, Tom

    2004-01-01

    We consider codes based on simple bipartite expander graphs. These codes may be seen as the first step leading from product type concatenated codes to more complex graph codes. We emphasize constructions of specific codes of realistic lengths, and study the details of decoding by message passing...

  13. Coded communications with nonideal interleaving

    Science.gov (United States)

    Laufer, Shaul

    1991-02-01

    Burst error channels - a type of block interference channels - feature increasing capacity but decreasing cutoff rate as the memory rate increases. Despite the large capacity, there is degradation in the performance of practical coding schemes when the memory length is excessive. A short-coding error parameter (SCEP) was introduced, which expresses a bound on the average decoding-error probability for codes shorter than the block interference length. The performance of a coded slow frequency-hopping communication channel is analyzed for worst-case partial band jamming and nonideal interleaving, by deriving expressions for the capacity and cutoff rate. The capacity and cutoff rate, respectively, are shown to approach and depart from those of a memoryless channel corresponding to the transmission of a single code letter per hop. For multiaccess communications over a slot-synchronized collision channel without feedback, the channel was considered as a block interference channel with memory length equal to the number of letters transmitted in each slot. The effects of an asymmetrical background noise and a reduced collision error rate were studied, as aspects of real communications. The performance of specific convolutional and Reed-Solomon codes was examined for slow frequency-hopping systems with nonideal interleaving. An upper bound is presented for the performance of a Viterbi decoder for a convolutional code with nonideal interleaving, and a soft decision diversity combining technique is introduced.

  14. Turbine model for the Laguna Verde nucleo electric central based in the RELAP code

    International Nuclear Information System (INIS)

    Cortes M, F.S.; Ramos P, J.C.; Salazar S, E.; Chavez M, C.

    2003-01-01

    The Nuclear Power stations as Laguna Verde occupy at the present time a place every time but important as non pollutant alternative, economic and trusty to generate electricity. It is for it that the Group of Nuclear Engineering of the Engineering Faculty (GrlNFI) of the National Autonomous University of Mexico (UNAM) it develops investigation projects applied to Nuclear Centrals. One of the projects in process is the development of a Classroom simulator, which it can configures to consent to diverse models of nuclear systems with training purposes in normal operation, or, to consent to specialized nuclear codes for the analysis of transitory events and have a severe accident. This work describes the development, implementation and it proves of a simplified model of the Main turbine to be integrated to the group of models of the Classroom simulator. It is part of the current effort of GrlNFI guided to obtain a representation of all the dynamic models necessary to simulate the Plant Balance of the Laguna Verde Central. It is included the development of the unfolding graphic which represent the modeling of the Main turbine, and of the control interface that allows the user to manipulate in simple way, direct and interactive this device during the training or the analysis. With this work it is wanted to contribute to the training of new technicians and to support the operation personnel of the Centrals. Also, the developed infrastructure is guided to contribute in the design and analysis of new Nuclear Power stations with the contribution of new computational tools for the visualization, simulation and process control. (Author)

  15. Enhancement of the electrical characteristics of MOS capacitors by reducing the organic content of H2O-diluted Spin-On-Glass based oxides

    International Nuclear Information System (INIS)

    Molina, Joel; Munoz, Ana; Torres, Alfonso; Landa, Mauro; Alarcon, Pablo; Escobar, Manuel

    2011-01-01

    In this work, the physical, chemical and electrical properties of Metal-Oxide-Semiconductor (MOS) capacitors with Spin-On-Glass (SOG)-based thin films as gate dielectric have been investigated. Experiments of SOG diluted with two different solvents (2-propanol and deionized water) were done in order to reduce the viscosity of the SOG solution so that thinner films (down to ∼20 nm) could be obtained and their general characteristics compared. Thin films of SOG were deposited on silicon by the sol-gel technique and they were thermally annealed using conventional oxidation furnace and Rapid Thermal Processing (RTP) systems within N 2 ambient after deposition. SOG dilution using non-organic solvents like deionized water and further annealing (at relatively high temperatures ≥450 deg. C) are important processes intended to reduce the organic content of the films. Fourier-Transform Infrared (FTIR) Spectroscopy results have shown that water-diluted SOG films have a significant reduction in their organic content after increasing annealing temperature and/or dilution percentage when compared to those of undiluted SOG films. Both current-voltage (I-V) and capacitance-voltage (C-V) measurements show better electrical characteristics for SOG-films diluted in deionized water compared to those diluted in 2-propanol (which is an organic solvent). The electrical characteristics of H 2 O-diluted SOG thin films are very similar to those obtained from high quality thermal oxides so that their application as gate dielectrics in MOS devices is promising. Finally, it has been demonstrated that by reducing the organic content of SOG-based thin films, it is possible to obtain MOS devices with better electrical properties.

  16. Electricity theft: a comparative analysis

    International Nuclear Information System (INIS)

    Smith, T.B.

    2004-01-01

    Electricity theft can be in the form of fraud (meter tampering), stealing (illegal connections), billing irregularities, and unpaid bills. Estimates of the extent of electricity theft in a sample of 102 countries for 1980 and 2000 are undertaken. The evidence shows that theft is increasing in most regions of the world. The financial impacts of theft are reduced income from the sale of electricity and the necessity to charge more to consumers. Electricity theft is closely related to governance indicators, with higher levels of theft in countries without effective accountability, political instability, low government effectiveness and high levels of corruption. Electricity theft can be reduced by applying technical solutions such as tamper-proof meters, managerial methods such as inspection and monitoring, and in some cases restructuring power systems ownership and regulation

  17. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  18. Reduction of momentum transfer rates by parallel electric fields: A two-fluid demonstration

    International Nuclear Information System (INIS)

    Delamere, P.A.; Stenbaek-Nielsen, H.C.; Otto, A.

    2002-01-01

    Momentum transfer between an ionized gas cloud moving relative to an ambient magnetized plasma is a general problem in space plasma physics. Obvious examples include the Io-Jupiter interaction, comets, and coronal mass ejections. Active plasma experiments have demonstrated that momentum transfer rates associated with Alfven wave propagation are poorly understood. Barium injection experiments from the Combined Release and Radiation Effects Satellite (CRRES) have shown that dense ionized clouds are capable of ExB drifting over large distances perpendicular to the magnetic field. The CRRES 'skidding' distances were much larger than predicted by magnetohydrodynamic theory and it has been proposed that parallel electric fields were a key component in the skidding phenomenon. A two-fluid code was used to demonstrate the role of parallel electric fields in reducing momentum transfer between two distinct plasma populations. In this study, a dense plasma was initialized moving relative to an ambient plasma and perpendicular to B. Parallel electric fields were introduced via a friction term in the electron momentum equation and the collision frequency was scaled in proportion to the field-aligned current density. The simulation results showed that parallel electric fields decreased the decelerating magnetic tension force on the plasma cloud through a magnetic diffusion/reconnection process

  19. Decoding LDPC Convolutional Codes on Markov Channels

    Directory of Open Access Journals (Sweden)

    Kashyap Manohar

    2008-01-01

    Full Text Available Abstract This paper describes a pipelined iterative technique for joint decoding and channel state estimation of LDPC convolutional codes over Markov channels. Example designs are presented for the Gilbert-Elliott discrete channel model. We also compare the performance and complexity of our algorithm against joint decoding and state estimation of conventional LDPC block codes. Complexity analysis reveals that our pipelined algorithm reduces the number of operations per time step compared to LDPC block codes, at the expense of increased memory and latency. This tradeoff is favorable for low-power applications.

  20. Decoding LDPC Convolutional Codes on Markov Channels

    Directory of Open Access Journals (Sweden)

    Chris Winstead

    2008-04-01

    Full Text Available This paper describes a pipelined iterative technique for joint decoding and channel state estimation of LDPC convolutional codes over Markov channels. Example designs are presented for the Gilbert-Elliott discrete channel model. We also compare the performance and complexity of our algorithm against joint decoding and state estimation of conventional LDPC block codes. Complexity analysis reveals that our pipelined algorithm reduces the number of operations per time step compared to LDPC block codes, at the expense of increased memory and latency. This tradeoff is favorable for low-power applications.

  1. Performance of FSO-OFDM based on BCH code

    Directory of Open Access Journals (Sweden)

    Jiao Xiao-lu

    2016-01-01

    Full Text Available As contrasted with the traditional OOK (on-off key system, FSO-OFDM system can resist the atmospheric scattering and improve the spectrum utilization rate effectively. Due to the instability of the atmospheric channel, the system will be affected by various factors, and resulting in a high BER. BCH code has a good error correcting ability, particularly in the short-length and medium-length code, and its performance is close to the theoretical value. It not only can check the burst errors but also can correct the random errors. Therefore, the BCH code is applied to the system to reduce the system BER. At last, the semi-physical simulation has been conducted with MATLAB. The simulation results show that when the BER is 10-2, the performance of OFDM is superior 4dB compared with OOK. In different weather conditions (extension rain, advection fog, dust days, when the BER is 10-5, the performance of BCH (255,191 channel coding is superior 4~5dB compared with uncoded system. All in all, OFDM technology and BCH code can reduce the system BER.

  2. Reduced-Rank Chip-Level MMSE Equalization for the 3G CDMA Forward Link with Code-Multiplexed Pilot

    Directory of Open Access Journals (Sweden)

    Goldstein J Scott

    2002-01-01

    Full Text Available This paper deals with synchronous direct-sequence code-division multiple access (CDMA transmission using orthogonal channel codes in frequency selective multipath, motivated by the forward link in 3G CDMA systems. The chip-level minimum mean square error (MMSE estimate of the (multiuser synchronous sum signal transmitted by the base, followed by a correlate and sum, has been shown to perform very well in saturated systems compared to a Rake receiver. In this paper, we present the reduced-rank, chip-level MMSE estimation based on the multistage nested Wiener filter (MSNWF. We show that, for the case of a known channel, only a small number of stages of the MSNWF is needed to achieve near full-rank MSE performance over a practical single-to-noise ratio (SNR range. This holds true even for an edge-of-cell scenario, where two base stations are contributing near equal-power signals, as well as for the single base station case. We then utilize the code-multiplexed pilot channel to train the MSNWF coefficients and show that adaptive MSNWF operating in a very low rank subspace performs slightly better than full-rank recursive least square (RLS and significantly better than least mean square (LMS. An important advantage of the MSNWF is that it can be implemented in a lattice structure, which involves significantly less computation than RLS. We also present structured MMSE equalizers that exploit the estimate of the multipath arrival times and the underlying channel structure to project the data vector onto a much lower dimensional subspace. Specifically, due to the sparseness of high-speed CDMA multipath channels, the channel vector lies in the subspace spanned by a small number of columns of the pulse shaping filter convolution matrix. We demonstrate that the performance of these structured low-rank equalizers is much superior to unstructured equalizers in terms of convergence speed and error rates.

  3. Static Code Analysis with Gitlab-CI

    CERN Document Server

    Datko, Szymon Tomasz

    2016-01-01

    Static Code Analysis is a simple but efficient way to ensure that application’s source code is free from known flaws and security vulnerabilities. Although such analysis tools are often coming with more advanced code editors, there are a lot of people who prefer less complicated environments. The easiest solution would involve education – where to get and how to use the aforementioned tools. However, counting on the manual usage of such tools still does not guarantee their actual usage. On the other hand, reducing the required effort, according to the idea “setup once, use anytime without sweat” seems like a more promising approach. In this paper, the approach to automate code scanning, within the existing CERN’s Gitlab installation, is described. For realization of that project, the Gitlab-CI service (the “CI” stands for "Continuous Integration"), with Docker assistance, was employed to provide a variety of static code analysers for different programming languages. This document covers the gene...

  4. Fast QC-LDPC code for free space optical communication

    Science.gov (United States)

    Wang, Jin; Zhang, Qi; Udeh, Chinonso Paschal; Wu, Rangzhong

    2017-02-01

    Free Space Optical (FSO) Communication systems use the atmosphere as a propagation medium. Hence the atmospheric turbulence effects lead to multiplicative noise related with signal intensity. In order to suppress the signal fading induced by multiplicative noise, we propose a fast Quasi-Cyclic (QC) Low-Density Parity-Check (LDPC) code for FSO Communication systems. As a linear block code based on sparse matrix, the performances of QC-LDPC is extremely near to the Shannon limit. Currently, the studies on LDPC code in FSO Communications is mainly focused on Gauss-channel and Rayleigh-channel, respectively. In this study, the LDPC code design over atmospheric turbulence channel which is nether Gauss-channel nor Rayleigh-channel is closer to the practical situation. Based on the characteristics of atmospheric channel, which is modeled as logarithmic-normal distribution and K-distribution, we designed a special QC-LDPC code, and deduced the log-likelihood ratio (LLR). An irregular QC-LDPC code for fast coding, of which the rates are variable, is proposed in this paper. The proposed code achieves excellent performance of LDPC codes and can present the characteristics of high efficiency in low rate, stable in high rate and less number of iteration. The result of belief propagation (BP) decoding shows that the bit error rate (BER) obviously reduced as the Signal-to-Noise Ratio (SNR) increased. Therefore, the LDPC channel coding technology can effectively improve the performance of FSO. At the same time, the BER, after decoding reduces with the increase of SNR arbitrarily, and not having error limitation platform phenomenon with error rate slowing down.

  5. Fixed capacity and variable member grouping assignment of orthogonal variable spreading factor code tree for code division multiple access networks

    Directory of Open Access Journals (Sweden)

    Vipin Balyan

    2014-08-01

    Full Text Available Orthogonal variable spreading factor codes are used in the downlink to maintain the orthogonality between different channels and are used to handle new calls arriving in the system. A period of operation leads to fragmentation of vacant codes. This leads to code blocking problem. The assignment scheme proposed in this paper is not affected by fragmentation, as the fragmentation is generated by the scheme itself. In this scheme, the code tree is divided into groups whose capacity is fixed and numbers of members (codes are variable. A group with maximum number of busy members is used for assignment, this leads to fragmentation of busy groups around code tree and compactness within group. The proposed scheme is well evaluated and compared with other schemes using parameters like code blocking probability and call establishment delay. Through simulations it has been demonstrated that the proposed scheme not only adequately reduces code blocking probability, but also requires significantly less time before assignment to locate a vacant code for assignment, which makes it suitable for the real-time calls.

  6. The SWAN coupling code: user's guide

    International Nuclear Information System (INIS)

    Litaudon, X.; Moreau, D.

    1988-11-01

    Coupling of slow waves in a plasma near the lower hybrid frequency is well known and linear theory with density step followed by a constant gradient can be used with some confidence. With the aid of the computer code SWAN, which stands for 'Slow Wave Antenna', the following parameters can be numerically calculated: n parallel power spectrum, directivity (weighted by the current drive efficiency), reflection coefficients (amplitude and phase) both before and after the E-plane junctions, scattering matrix at the plasma interface, scattering matrix at the E-plane junctions, maximum electric fields in secondary waveguides and location where it occurs, effect of passive waveguides on each side of the antenna, and the effect of a finite magnetic field in front of the antenna (for homogeneous plasma). This manual gives the basic information on the main assumptions of the coupling theory and on the use and general structure of the code itself. It answers the questions what are the main assumptions of the physical model? how to execute a job? what are the input parameters of the code? and what are the output results and where are they written? (author)

  7. General conditions for electric power supply

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    If it is uncertain whether future power bills will be paid fully, it is admissible to take an action claiming a declaration which states that the electricity rate payment boycotter has no right to non-payment nor a right to withhold payment towards the electricity supply utility, and that the electricity supply utility has the right to stop energy supply because of reduced electricity rate payments effected and/or announced, and to denounce the contract without observing any term of notice. If the electricity buyer reduces a power bill to be paid without any legal grounds, the electricity supply utility has the right to stop power supplies and to denounce the power supply contract without observing any term of notice. The freedom of thought and the freedom of opinion must not be expressed by reducing power bills to be paid. Basic rights discontinue to be effective as soon as a contract or law is broken. A weighing of protected interests is not effected if the exercise of a basic law is unlawful. (orig./HP) [de

  8. Performance Analysis of Optical Code Division Multiplex System

    Science.gov (United States)

    Kaur, Sandeep; Bhatia, Kamaljit Singh

    2013-12-01

    This paper presents the Pseudo-Orthogonal Code generator for Optical Code Division Multiple Access (OCDMA) system which helps to reduce the need of bandwidth expansion and improve spectral efficiency. In this paper we investigate the performance of multi-user OCDMA system to achieve data rate more than 1 Tbit/s.

  9. Relationship between various pressure vessel and piping codes

    International Nuclear Information System (INIS)

    Canonico, D.A.

    1976-01-01

    Section VIII of the ASME Code provides stress allowable values for material specifications that are provided in Section II Parts A and B. Since the adoption of the ASME Code over 60 years ago the incidence of failure has been greatly reduced. The Codes are currently based on strength criteria and advancements in the technology of fracture toughness and fracture mechanics should permit an even greater degree of reliability and safety. This lecture discusses the various Sections of the Code. It describes the basis for the establishment of design stress allowables and promotes the idea of the use of fracture mechanics

  10. A hybrid self-adaptive Particle Swarm Optimization–Genetic Algorithm–Radial Basis Function model for annual electricity demand prediction

    International Nuclear Information System (INIS)

    Yu, Shiwei; Wang, Ke; Wei, Yi-Ming

    2015-01-01

    Highlights: • A hybrid self-adaptive PSO–GA-RBF model is proposed for electricity demand prediction. • Each mixed-coding particle is composed by two coding parts of binary and real. • Five independent variables have been selected to predict future electricity consumption in Wuhan. • The proposed model has a simpler structure or higher estimating precision than other ANN models. • No matter what the scenario, the electricity consumption of Wuhan will grow rapidly. - Abstract: The present study proposes a hybrid Particle Swarm Optimization and Genetic Algorithm optimized Radial Basis Function (PSO–GA-RBF) neural network for prediction of annual electricity demand. In the model, each mixed-coding particle (or chromosome) is composed of two coding parts, binary and real, which optimizes the structure of the RBF by GA operation and the parameters of the basis and weights by a PSO–GA implementation. Five independent variables have been selected to predict future electricity consumption in Wuhan by using optimized networks. The results shows that (1) the proposed PSO–GA-RBF model has a simpler network structure (fewer hidden neurons) or higher estimation precision than other selected ANN models; and (2) no matter what the scenario, the electricity consumption of Wuhan will grow rapidly at average annual growth rates of about 9.7–11.5%. By 2020, the electricity demand in the planning scenario, the highest among the scenarios, will be 95.85 billion kW h. The lowest demand is estimated for the business-as-usual scenario, and will be 88.45 billion kW h

  11. C++ Coding Standards 101 Rules, Guidelines, and Best Practices

    CERN Document Server

    Sutter, Herb

    2005-01-01

    Consistent, high-quality coding standards improve software quality, reduce time-to-market, promote teamwork, eliminate time wasted on inconsequential matters, and simplify maintenance. Now, two of the world's most respected C++ experts distill the rich collective experience of the global C++ community into a set of coding standards that every developer and development team can understand and use as a basis for their own coding standards.

  12. Toric Varieties and Codes, Error-correcting Codes, Quantum Codes, Secret Sharing and Decoding

    DEFF Research Database (Denmark)

    Hansen, Johan Peder

    We present toric varieties and associated toric codes and their decoding. Toric codes are applied to construct Linear Secret Sharing Schemes (LSSS) with strong multiplication by the Massey construction. Asymmetric Quantum Codes are obtained from toric codes by the A.R. Calderbank P.W. Shor and A.......M. Steane construction of stabilizer codes (CSS) from linear codes containing their dual codes....

  13. Computer code for quantitative ALARA evaluations

    International Nuclear Information System (INIS)

    Voilleque, P.G.

    1984-01-01

    A FORTRAN computer code has been developed to simplify the determination of whether dose reduction actions meet the as low as is reasonably achievable (ALARA) criterion. The calculations are based on the methodology developed for the Atomic Industrial Forum. The code is used for analyses of eight types of dose reduction actions, characterized as follows: reduce dose rate, reduce job frequency, reduce productive working time, reduce crew size, increase administrative dose limit for the task, and increase the workers' time utilization and dose utilization through (a) improved working conditions, (b) basic skill training, or (c) refresher training for special skills. For each type of action, two analysis modes are available. The first is a generic analysis in which the program computes potential benefits (in dollars) for a range of possible improvements, e.g., for a range of lower dose rates. Generic analyses are most useful in the planning stage and for evaluating the general feasibility of alternative approaches. The second is a specific analysis in which the potential annual benefits of a specific level of improvement and the annual implementation cost are compared. The potential benefits reflect savings in operational and societal costs that can be realized if occupational radiation doses are reduced. Because the potential benefits depend upon many variables which characterize the job, the workplace, and the workers, there is no unique relationship between the potential dollar savings and the dose savings. The computer code permits rapid quantitative analyses of alternatives and is a tool that supplements the health physicist's professional judgment. The program output provides a rational basis for decision-making and a record of the assumptions employed

  14. Encoding of QC-LDPC Codes of Rank Deficient Parity Matrix

    Directory of Open Access Journals (Sweden)

    Mohammed Kasim Mohammed Al-Haddad

    2016-05-01

    Full Text Available the encoding of long low density parity check (LDPC codes presents a challenge compared to its decoding. The Quasi Cyclic (QC LDPC codes offer the advantage for reducing the complexity for both encoding and decoding due to its QC structure. Most QC-LDPC codes have rank deficient parity matrix and this introduces extra complexity over the codes with full rank parity matrix. In this paper an encoding scheme of QC-LDPC codes is presented that is suitable for codes with full rank parity matrix and rank deficient parity matrx. The extra effort required by the codes with rank deficient parity matrix over the codes of full rank parity matrix is investigated.

  15. Future electricity: The challenge of reducing both carbon and water footprint.

    Science.gov (United States)

    Mekonnen, Mesfin M; Gerbens-Leenes, P W; Hoekstra, Arjen Y

    2016-11-01

    We estimate the consumptive water footprint (WF) of electricity and heat in 2035 for the four energy scenarios of the International Energy Agency (IEA) and a fifth scenario with a larger percentage of solar energy. Counter-intuitively, the 'greenest' IEA scenario (with the smallest carbon footprint) shows the largest WF increase over time: an increase by a factor four over the period 2010-2035. In 2010, electricity from solar, wind, and geothermal contributed 1.8% to the total. The increase of this contribution to 19.6% in IEA's '450 scenario' contributes significantly to the decrease of the WF of the global electricity and heat sector, but is offset by the simultaneous increase of the use of firewood and hydropower. Only substantial growth in the fractions of energy sources with small WFs - solar, wind, and geothermal energy - can contribute to a lowering of the WF of the electricity and heat sector in the coming decades. The fifth energy scenario - adapted from the IEA 450 scenario but based on a quick transition to solar, wind and geothermal energy and a minimum in bio-energy - is the only scenario that shows a strong decline in both carbon footprint (-66%) and consumptive WF (-12%) in 2035 compared to the reference year 2010. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Wavelet-based information filtering for fault diagnosis of electric drive systems in electric ships.

    Science.gov (United States)

    Silva, Andre A; Gupta, Shalabh; Bazzi, Ali M; Ulatowski, Arthur

    2017-09-22

    Electric machines and drives have enjoyed extensive applications in the field of electric vehicles (e.g., electric ships, boats, cars, and underwater vessels) due to their ease of scalability and wide range of operating conditions. This stems from their ability to generate the desired torque and power levels for propulsion under various external load conditions. However, as with the most electrical systems, the electric drives are prone to component failures that can degrade their performance, reduce the efficiency, and require expensive maintenance. Therefore, for safe and reliable operation of electric vehicles, there is a need for automated early diagnostics of critical failures such as broken rotor bars and electrical phase failures. In this regard, this paper presents a fault diagnosis methodology for electric drives in electric ships. This methodology utilizes the two-dimensional, i.e. scale-shift, wavelet transform of the sensor data to filter optimal information-rich regions which can enhance the diagnosis accuracy as well as reduce the computational complexity of the classifier. The methodology was tested on sensor data generated from an experimentally validated simulation model of electric drives under various cruising speed conditions. The results in comparison with other existing techniques show a high correct classification rate with low false alarm and miss detection rates. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Improved lossless intra coding for H.264/MPEG-4 AVC.

    Science.gov (United States)

    Lee, Yung-Lyul; Han, Ki-Hun; Sullivan, Gary J

    2006-09-01

    A new lossless intra coding method based on sample-by-sample differential pulse code modulation (DPCM) is presented as an enhancement of the H.264/MPEG-4 AVC standard. The H.264/AVC design includes a multidirectional spatial prediction method to reduce spatial redundancy by using neighboring samples as a prediction for the samples in a block of data to be encoded. In the new lossless intra coding method, the spatial prediction is performed based on samplewise DPCM instead of in the block-based manner used in the current H.264/AVC standard, while the block structure is retained for the residual difference entropy coding process. We show that the new method, based on samplewise DPCM, does not have a major complexity penalty, despite its apparent pipeline dependencies. Experiments show that the new lossless intra coding method reduces the bit rate by approximately 12% in comparison with the lossless intra coding method previously included in the H.264/AVC standard. As a result, the new method is currently being adopted into the H.264/AVC standard in a new enhancement project.

  18. Container code recognition in information auto collection system of container inspection

    International Nuclear Information System (INIS)

    Su Jianping; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2003-01-01

    Now custom needs electrical application and automatic detection. Container inspection should not only give the image of the goods, but also auto-attain container's code and weight. Its function and track control, information transfer make up the Information Auto Collection system of Container Inspection. Code Recognition is the point. The article is based on model match, the close property of character, and uses it to recognize. Base on checkout rule, design the adjustment arithmetic, form the whole recognition strategy. This strategy can achieve high recognition ratio and robust property

  19. Development of a new EMP code at LANL

    Science.gov (United States)

    Colman, J. J.; Roussel-Dupré, R. A.; Symbalisty, E. M.; Triplett, L. A.; Travis, B. J.

    2006-05-01

    A new code for modeling the generation of an electromagnetic pulse (EMP) by a nuclear explosion in the atmosphere is being developed. The source of the EMP is the Compton current produced by the prompt radiation (γ-rays, X-rays, and neutrons) of the detonation. As a first step in building a multi- dimensional EMP code we have written three kinetic codes, Plume, Swarm, and Rad. Plume models the transport of energetic electrons in air. The Plume code solves the relativistic Fokker-Planck equation over a specified energy range that can include ~ 3 keV to 50 MeV and computes the resulting electron distribution function at each cell in a two dimensional spatial grid. The energetic electrons are allowed to transport, scatter, and experience Coulombic drag. Swarm models the transport of lower energy electrons in air, spanning 0.005 eV to 30 keV. The swarm code performs a full 2-D solution to the Boltzmann equation for electrons in the presence of an applied electric field. Over this energy range the relevant processes to be tracked are elastic scattering, three body attachment, two body attachment, rotational excitation, vibrational excitation, electronic excitation, and ionization. All of these occur due to collisions between the electrons and neutral bodies in air. The Rad code solves the full radiation transfer equation in the energy range of 1 keV to 100 MeV. It includes effects of photo-absorption, Compton scattering, and pair-production. All of these codes employ a spherical coordinate system in momentum space and a cylindrical coordinate system in configuration space. The "z" axis of the momentum and configuration spaces is assumed to be parallel and we are currently also assuming complete spatial symmetry around the "z" axis. Benchmarking for each of these codes will be discussed as well as the way forward towards an integrated modern EMP code.

  20. Development of a NSSS T/H Module for the YGN 1/2 NPP Simulator Using a Best-Estimate Code, RETRAN

    International Nuclear Information System (INIS)

    Seo, I. Y.; Lee, Y. K.; Jeun, G. D.; Suh, J. S.

    2005-01-01

    KEPRI(Korea Electric Power Research Institute) developed a realistic nuclear steam supply system thermal-hydraulic module, named ARTS code, based on the best-estimate code RETRAN for the improvement of the KNPEC(Korea Nuclear Plant Education Center) unit 2 full-scope simulator. In this work, we make a nuclear steam supply system thermal-hydraulic module for the YGN 1/2 nuclear power plant simulator using a practical application of a experience of ARTS code development. The ARTS code was developed based on RETRAN, which is a best estimate code developed by EPRI(Electric Power Research Institute) for various transient analyses of NPP(Nuclear Power Plants). Robustness and the real time calculation capability have been improved by simplifications, removing of discontinuities of the physical correlations of the RETRAN code and some other modifications. And its scope for the simulation has been extended by supplementation of new calculation modules such as a dedicated pressurizer relief tank model and a backup model. The supplement is developed so that users cannot recognize the model change from the main ARTS module

  1. Automatic coding method of the ACR Code

    International Nuclear Information System (INIS)

    Park, Kwi Ae; Ihm, Jong Sool; Ahn, Woo Hyun; Baik, Seung Kook; Choi, Han Yong; Kim, Bong Gi

    1993-01-01

    The authors developed a computer program for automatic coding of ACR(American College of Radiology) code. The automatic coding of the ACR code is essential for computerization of the data in the department of radiology. This program was written in foxbase language and has been used for automatic coding of diagnosis in the Department of Radiology, Wallace Memorial Baptist since May 1992. The ACR dictionary files consisted of 11 files, one for the organ code and the others for the pathology code. The organ code was obtained by typing organ name or code number itself among the upper and lower level codes of the selected one that were simultaneous displayed on the screen. According to the first number of the selected organ code, the corresponding pathology code file was chosen automatically. By the similar fashion of organ code selection, the proper pathologic dode was obtained. An example of obtained ACR code is '131.3661'. This procedure was reproducible regardless of the number of fields of data. Because this program was written in 'User's Defined Function' from, decoding of the stored ACR code was achieved by this same program and incorporation of this program into program in to another data processing was possible. This program had merits of simple operation, accurate and detail coding, and easy adjustment for another program. Therefore, this program can be used for automation of routine work in the department of radiology

  2. Analysis of electricity price in Danish competitive electricity market

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2012-01-01

    electricity markets in some ways, is chosen as the studied power system. 10 year actual data from the Danish competitive electricity market are collected and analyzed. The relationship among the electricity price (both the spot price and the regulation price), the consumption and the wind power generation...... in an electricity market is investigated in this paper. The spot price and the regulation price generally decrease when the wind power penetration in the power system increases or the consumption of the power system decreases. The statistical characteristics of the spot price and the regulation price for different...... consumption periods and wind power penetration are analyzed. Simulation results show that the findings of this paper are useful for wind power generation companies to make the optimal bidding strategy so that the imbalance cost of trading wind power on the electricity market could be reduced....

  3. Advanced Imaging Optics Utilizing Wavefront Coding.

    Energy Technology Data Exchange (ETDEWEB)

    Scrymgeour, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Boye, Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Adelsberger, Kathleen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    Image processing offers a potential to simplify an optical system by shifting some of the imaging burden from lenses to the more cost effective electronics. Wavefront coding using a cubic phase plate combined with image processing can extend the system's depth of focus, reducing many of the focus-related aberrations as well as material related chromatic aberrations. However, the optimal design process and physical limitations of wavefront coding systems with respect to first-order optical parameters and noise are not well documented. We examined image quality of simulated and experimental wavefront coded images before and after reconstruction in the presence of noise. Challenges in the implementation of cubic phase in an optical system are discussed. In particular, we found that limitations must be placed on system noise, aperture, field of view and bandwidth to develop a robust wavefront coded system.

  4. Cost-effectiveness of plug-in hybrid electric vehicle battery capacity and charging infrastructure investment for reducing US gasoline consumption

    International Nuclear Information System (INIS)

    Peterson, Scott B.; Michalek, Jeremy J.

    2013-01-01

    Federal electric vehicle (EV) policies in the United States currently include vehicle purchase subsidies linked to EV battery capacity and subsidies for installing charging stations. We assess the cost-effectiveness of increased battery capacity vs. nondomestic charging infrastructure installation for plug-in hybrid electric vehicles as alternate methods to reduce gasoline consumption for cars, trucks, and SUVs in the US. We find across a wide range of scenarios that the least-cost solution is for more drivers to switch to low-capacity plug-in hybrid electric vehicles (short electric range with gasoline backup for long trips) or gasoline-powered hybrid electric vehicles. If more gasoline savings are needed per vehicle, nondomestic charging infrastructure installation is substantially more expensive than increased battery capacity per gallon saved, and both approaches have higher costs than US oil premium estimates. Cost effectiveness of all subsidies are lower under a binding fuel economy standard. Comparison of results to the structure of current federal subsidies shows that policy is not aligned with fuel savings potential, and we discuss issues and alternatives. - Highlights: ► We compare cost of PHEV batteries vs. charging infrastructure per gallon of gasoline saved. ► The lowest cost solution is to switch more drivers to low-capacity PHEVs and HEVs. ► If more gasoline savings is needed, batteries offer a better value than chargers. ► Extra batteries and chargers are both more costly per gal than oil premium estimates. ► Current subsidies are misaligned with fuel savings. We discuss alternatives.

  5. EBQ code: Transport of space-charge beams in axially symmetric devices

    Science.gov (United States)

    Paul, A. C.

    1982-11-01

    Such general-purpose space charge codes as EGUN, BATES, WODF, and TRANSPORT do not gracefully accommodate the simulation of relativistic space-charged beams propagating a long distance in axially symmetric devices where a high degree of cancellation has occurred between the self-magnetic and self-electric forces of the beam. The EBQ code was written specifically to follow high current beam particles where space charge is important in long distance flight in axially symmetric machines possessing external electric and magnetic field. EBQ simultaneously tracks all trajectories so as to allow procedures for charge deposition based on inter-ray separations. The orbits are treated in Cartesian geometry (position and momentum) with z as the independent variable. Poisson's equation is solved in cylindrical geometry on an orthogonal rectangular mesh. EBQ can also handle problems involving multiple ion species where the space charge from each must be included. Such problems arise in the design of ion sources where different charge and mass states are present.

  6. EBQ code: transport of space-charge beams in axially symmetric devices

    International Nuclear Information System (INIS)

    Paul, A.C.

    1982-11-01

    Such general-purpose space charge codes as EGUN, BATES, WOLF, and TRANSPORT do not gracefully accommodate the simulation of relativistic space-charged beams propagating a long distance in axially symmetric devices where a high degree of cancellation has occurred between the self-magnetic and self-electric forces of the beam. The EBQ code was written specifically to follow high current beam particles where space charge is important in long distance flight in axially symmetric machines possessing external electric and magnetic field. EBQ simultaneously tracks all trajectories so as to allow procedures for charge deposition based on inter-ray separations. The orbits are treated in Cartesian geometry (position and momentum) with z as the independent variable. Poisson's equation is solved in cylindrical geometry on an orthogonal rectangular mesh. EBQ can also handle problems involving multiple ion species where the space charge from each must be included. Such problems arise in the design of ion sources where different charge and mass states are present

  7. Effects of regulatory reforms in the electricity supply industry on electricity prices in developing countries

    International Nuclear Information System (INIS)

    Nagayama, Hiroaki

    2007-01-01

    Electric power sector reforms in the electricity supply industry have had an impact on industrial and household prices in developing countries in Latin America, the former Soviet Union, and Eastern Europe. Using original panel data for 83 countries during the period from 1985 to 2002, we examine how each policy instrument of the reform measures influenced electricity prices for countries in the above regions. We found that variables such as entry of independent power producers (IPP), unbundling of generation and transmission, establishment of a regulatory agency, and the introduction of a wholesale spot market have had a variety of impacts on electricity prices, some of which were not always consistent with expected results. The research findings suggest that neither unbundling nor introduction of a wholesale pool market on their own necessarily reduces the electric power price. In fact, contrary to expectations, there was a tendency for the price to rise. However, coexistent with an independent regulator, unbundling may work to reduce electricity prices. Privatization and the introduction of foreign IPP and retail competition lower electricity prices in some regions, but not all

  8. Sequence Coding and Search System for licensee event reports: code listings. Volume 2

    International Nuclear Information System (INIS)

    Gallaher, R.B.; Guymon, R.H.; Mays, G.T.; Poore, W.P.; Cagle, R.J.; Harrington, K.H.; Johnson, M.P.

    1985-04-01

    Operating experience data from nuclear power plants are essential for safety and reliability analyses, especially analyses of trends and patterns. The licensee event reports (LERs) that are submitted to the Nuclear Regulatory Commission (NRC) by the nuclear power plant utilities contain much of this data. The NRC's Office for Analysis and Evaluation of Operational Data (AEOD) has developed, under contract with NSIC, a system for codifying the events reported in the LERs. The primary objective of the Sequence Coding and Search System (SCSS) is to reduce the descriptive text of the LERs to coded sequences that are both computer-readable and computer-searchable. This system provides a structured format for detailed coding of component, system, and unit effects as well as personnel errors. The database contains all current LERs submitted by nuclear power plant utilities for events occurring since 1981 and is updated on a continual basis. Volume 2 contains all valid and acceptable codes used for searching and encoding the LER data. This volume contains updated material through amendment 1 to revision 1 of the working version of ORNL/NSIC-223, Vol. 2

  9. Saving electricity in a hurry. Dealing with temporary shortfalls in electricity supplies

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Blackouts are normally the result of imbalances in electricity supply and demand. A brief blackout is mostly an inconvenience. But persistent shortfalls ? those lasting days, weeks, or months ? can cause economic disruption and danger to human life in our technology-rich societies. Saving Electricity in a Hurry describes some of the recent power shortfalls, from Norway to New Zealand, from Tokyo to Arizona and the policies these regions used to quickly reduce their power consumption. How did the whole country of Sweden cut its power consumption by 4% in only three days? How did California save 14% in only a few months? While the temporary shortfalls in electricity supplies described in this book are relatively rare events, they disproportionately shape future energy policies. Saving Electricity in a Hurry shows that countries can quickly reduce electricity consumption without harming the economy as much as blackouts or unplanned curtailments. The strategies are diverse, unique and often surprisingly cheap. They include mass media campaigns ? where a good joke can save a Megawatt ? improvements in equipment efficiency and quickly adjusting electricity prices. This book explains how California replaced a million traffic signals with energy-saving models, how millions of Tokyo residents raised their thermostat settings, and how New Zealanders took shorter showers, all quickly enough to help avoid imminent blackouts. Finally, it connects these policies to the traditional goal of ?saving electricity slowly?.

  10. Objectivity in Grading: The Promise of Bar Codes

    Science.gov (United States)

    Jae, Haeran; Cowling, John

    2009-01-01

    This article proposes the use of a new technology to assure student anonymity and reduce bias hazards: identifying students by using bar codes. The limited finding suggests that the use of bar codes for assuring student anonymity could potentially cause students to perceive that grades are assigned more fairly and reassure teachers that they are…

  11. [A comparison of time resolution among auditory, tactile and promontory electrical stimulation--superiority of cochlear implants as human communication aids].

    Science.gov (United States)

    Matsushima, J; Kumagai, M; Harada, C; Takahashi, K; Inuyama, Y; Ifukube, T

    1992-09-01

    Our previous reports showed that second formant information, using a speech coding method, could be transmitted through an electrode on the promontory. However, second formant information can also be transmitted by tactile stimulation. Therefore, to find out whether electrical stimulation of the auditory nerve would be superior to tactile stimulation for our speech coding method, the time resolutions of the two modes of stimulation were compared. The results showed that the time resolution of electrical promontory stimulation was three times better than the time resolution of tactile stimulation of the finger. This indicates that electrical stimulation of the auditory nerve is much better for our speech coding method than tactile stimulation of the finger.

  12. New electromagnetic particle simulation code for the analysis of spacecraft-plasma interactions

    International Nuclear Information System (INIS)

    Miyake, Yohei; Usui, Hideyuki

    2009-01-01

    A novel particle simulation code, the electromagnetic spacecraft environment simulator (EMSES), has been developed for the self-consistent analysis of spacecraft-plasma interactions on the full electromagnetic (EM) basis. EMSES includes several boundary treatments carefully coded for both longitudinal and transverse electric fields to satisfy perfect conductive surface conditions. For the longitudinal component, the following are considered: (1) the surface charge accumulation caused by impinging or emitted particles and (2) the surface charge redistribution, such that the surface becomes an equipotential. For item (1), a special treatment has been adopted for the current density calculated around the spacecraft surface, so that the charge accumulation occurs exactly on the surface. As a result, (1) is realized automatically in the updates of the charge density and the electric field through the current density. Item (2) is achieved by applying the capacity matrix method. Meanwhile, the transverse electric field is simply set to zero for components defined inside and tangential to the spacecraft surfaces. This paper also presents the validation of EMSES by performing test simulations for spacecraft charging and peculiar EM wave modes in a plasma sheath.

  13. COSY 5.0 - the fifth order code for corpuscular optical systems

    International Nuclear Information System (INIS)

    Berz, M.; Hoffmann, H.C.; Wollnik, H.

    1987-01-01

    COSY 5.0 is a new computer code for the design of corpuscular optical systems based on the principle of transfer matrices. The particle optical calculations include all image aberrations through fifth order. COSY 5.0 uses canonical coordinates and exploits the symplectic condition to increase the speed of computation. COSY 5.0 contains a library for the computation of matrix elements of all commonly used corpuscular optical elements such as electric and magnetic multipoles and sector fields. The corresponding formulas were generated algebraically by the computer code HAMILTON. Care was taken that the optimization of optical elements is achieved with minimal numerical effort. Finally COSY 5.0 has a very general mnemonic input code resembling a higher programming language. (orig.)

  14. Coding in pigeons: Multiple-coding versus single-code/default strategies.

    Science.gov (United States)

    Pinto, Carlos; Machado, Armando

    2015-05-01

    To investigate the coding strategies that pigeons may use in a temporal discrimination tasks, pigeons were trained on a matching-to-sample procedure with three sample durations (2s, 6s and 18s) and two comparisons (red and green hues). One comparison was correct following 2-s samples and the other was correct following both 6-s and 18-s samples. Tests were then run to contrast the predictions of two hypotheses concerning the pigeons' coding strategies, the multiple-coding and the single-code/default. According to the multiple-coding hypothesis, three response rules are acquired, one for each sample. According to the single-code/default hypothesis, only two response rules are acquired, one for the 2-s sample and a "default" rule for any other duration. In retention interval tests, pigeons preferred the "default" key, a result predicted by the single-code/default hypothesis. In no-sample tests, pigeons preferred the key associated with the 2-s sample, a result predicted by multiple-coding. Finally, in generalization tests, when the sample duration equaled 3.5s, the geometric mean of 2s and 6s, pigeons preferred the key associated with the 6-s and 18-s samples, a result predicted by the single-code/default hypothesis. The pattern of results suggests the need for models that take into account multiple sources of stimulus control. © Society for the Experimental Analysis of Behavior.

  15. Row Reduction Applied to Decoding of Rank Metric and Subspace Codes

    DEFF Research Database (Denmark)

    Puchinger, Sven; Nielsen, Johan Sebastian Rosenkilde; Li, Wenhui

    2017-01-01

    We show that decoding of ℓ-Interleaved Gabidulin codes, as well as list-ℓ decoding of Mahdavifar–Vardy (MV) codes can be performed by row reducing skew polynomial matrices. Inspired by row reduction of F[x] matrices, we develop a general and flexible approach of transforming matrices over skew...... polynomial rings into a certain reduced form. We apply this to solve generalised shift register problems over skew polynomial rings which occur in decoding ℓ-Interleaved Gabidulin codes. We obtain an algorithm with complexity O(ℓμ2) where μ measures the size of the input problem and is proportional...... to the code length n in the case of decoding. Further, we show how to perform the interpolation step of list-ℓ-decoding MV codes in complexity O(ℓn2), where n is the number of interpolation constraints....

  16. EPR-technical codes - a common basis for the EPR

    International Nuclear Information System (INIS)

    Zaiss, W.; Appell, B.

    1997-01-01

    The design and construction of Nuclear Power Plants implies a full set of codes and standards to define the construction rules of components and equipment. Rules are existing and are currently implemented, respectively in France and Germany (mainly RCCs and KTA safety standards). In the frame of the EPR-project, the common objective requires an essential industrial work programme between engineers from both countries to elaborate a common set of codes and regulations. These new industrial rules are called the ETCs (EPR Technical Codes). In the hierarchy the ETCs are - in case of France - on the common level of basic safety rules (RFS), design and construction rules (RCC) and - in Germany - belonging to RSK guidelines and KTA safety standards. A set of six ETCs will be elaborated to cover: safety and process, mechanical components, electrical equipment, instrumentation and control, civil works, fire protection. (orig.)

  17. Utilizing GPUs to Accelerate Turbomachinery CFD Codes

    Science.gov (United States)

    MacCalla, Weylin; Kulkarni, Sameer

    2016-01-01

    GPU computing has established itself as a way to accelerate parallel codes in the high performance computing world. This work focuses on speeding up APNASA, a legacy CFD code used at NASA Glenn Research Center, while also drawing conclusions about the nature of GPU computing and the requirements to make GPGPU worthwhile on legacy codes. Rewriting and restructuring of the source code was avoided to limit the introduction of new bugs. The code was profiled and investigated for parallelization potential, then OpenACC directives were used to indicate parallel parts of the code. The use of OpenACC directives was not able to reduce the runtime of APNASA on either the NVIDIA Tesla discrete graphics card, or the AMD accelerated processing unit. Additionally, it was found that in order to justify the use of GPGPU, the amount of parallel work being done within a kernel would have to greatly exceed the work being done by any one portion of the APNASA code. It was determined that in order for an application like APNASA to be accelerated on the GPU, it should not be modular in nature, and the parallel portions of the code must contain a large portion of the code's computation time.

  18. Safety, codes and standards for hydrogen installations. Metrics development and benchmarking

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Aaron P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dedrick, Daniel E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Angela Christine [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); San Marchi, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-04-01

    Automakers and fuel providers have made public commitments to commercialize light duty fuel cell electric vehicles and fueling infrastructure in select US regions beginning in 2014. The development, implementation, and advancement of meaningful codes and standards is critical to enable the effective deployment of clean and efficient fuel cell and hydrogen solutions in the energy technology marketplace. Metrics pertaining to the development and implementation of safety knowledge, codes, and standards are important to communicate progress and inform future R&D investments. This document describes the development and benchmarking of metrics specific to the development of hydrogen specific codes relevant for hydrogen refueling stations. These metrics will be most useful as the hydrogen fuel market transitions from pre-commercial to early-commercial phases. The target regions in California will serve as benchmarking case studies to quantify the success of past investments in research and development supporting safety codes and standards R&D.

  19. Code Cactus; Code Cactus

    Energy Technology Data Exchange (ETDEWEB)

    Fajeau, M; Nguyen, L T; Saunier, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-09-01

    This code handles the following problems: -1) Analysis of thermal experiments on a water loop at high or low pressure; steady state or transient behavior; -2) Analysis of thermal and hydrodynamic behavior of water-cooled and moderated reactors, at either high or low pressure, with boiling permitted; fuel elements are assumed to be flat plates: - Flowrate in parallel channels coupled or not by conduction across plates, with conditions of pressure drops or flowrate, variable or not with respect to time is given; the power can be coupled to reactor kinetics calculation or supplied by the code user. The code, containing a schematic representation of safety rod behavior, is a one dimensional, multi-channel code, and has as its complement (FLID), a one-channel, two-dimensional code. (authors) [French] Ce code permet de traiter les problemes ci-dessous: 1. Depouillement d'essais thermiques sur boucle a eau, haute ou basse pression, en regime permanent ou transitoire; 2. Etudes thermiques et hydrauliques de reacteurs a eau, a plaques, a haute ou basse pression, ebullition permise: - repartition entre canaux paralleles, couples on non par conduction a travers plaques, pour des conditions de debit ou de pertes de charge imposees, variables ou non dans le temps; - la puissance peut etre couplee a la neutronique et une representation schematique des actions de securite est prevue. Ce code (Cactus) a une dimension d'espace et plusieurs canaux, a pour complement Flid qui traite l'etude d'un seul canal a deux dimensions. (auteurs)

  20. PEAK-TO-AVERAGE POWER RATIO REDUCTION USING CODING AND HYBRID TECHNIQUES FOR OFDM SYSTEM

    Directory of Open Access Journals (Sweden)

    Bahubali K. Shiragapur

    2016-03-01

    Full Text Available In this article, the research work investigated is based on an error correction coding techniques are used to reduce the undesirable Peak-to-Average Power Ratio (PAPR quantity. The Golay Code (24, 12, Reed-Muller code (16, 11, Hamming code (7, 4 and Hybrid technique (Combination of Signal Scrambling and Signal Distortion proposed by us are used as proposed coding techniques, the simulation results shows that performance of Hybrid technique, reduces PAPR significantly as compared to Conventional and Modified Selective mapping techniques. The simulation results are validated through statistical properties, for proposed technique’s autocorrelation value is maximum shows reduction in PAPR. The symbol preference is the key idea to reduce PAPR based on Hamming distance. The simulation results are discussed in detail, in this article.

  1. Lossless Image Compression Based on Multiple-Tables Arithmetic Coding

    Directory of Open Access Journals (Sweden)

    Rung-Ching Chen

    2009-01-01

    Full Text Available This paper is intended to present a lossless image compression method based on multiple-tables arithmetic coding (MTAC method to encode a gray-level image f. First, the MTAC method employs a median edge detector (MED to reduce the entropy rate of f. The gray levels of two adjacent pixels in an image are usually similar. A base-switching transformation approach is then used to reduce the spatial redundancy of the image. The gray levels of some pixels in an image are more common than those of others. Finally, the arithmetic encoding method is applied to reduce the coding redundancy of the image. To promote high performance of the arithmetic encoding method, the MTAC method first classifies the data and then encodes each cluster of data using a distinct code table. The experimental results show that, in most cases, the MTAC method provides a higher efficiency in use of storage space than the lossless JPEG2000 does.

  2. Numerical simulation of a short RFQ resonator using the MAFIA codes

    International Nuclear Information System (INIS)

    Wang, H.; Ben-Zvi, I.; Jain, A.; Paul, P.; Lombardi, A.

    1991-01-01

    The electrical characteristics of a short (2βλ=0.4 m) resonator with large modulation (m=4) have been studied using the three dimensional codes, MAFIA. The complete resonator, including the modulated electrodes and a complex support structure, has been simulated using ∼ 350,000 mesh points. Important characteristics studied include the resonant frequency, electric and magnetic fields distributions, quality factor and stored energy. The results of the numerical simulations are compared with the measurements of an actual resonator and analytical approximations. 7 refs., 3 figs., 1 tab

  3. A code to compute borehole fluid conductivity profiles with multiple feed points

    International Nuclear Information System (INIS)

    Hale, F.V.; Tsang, C.F.

    1988-03-01

    It is of much current interest to determine the flow characteristics of fractures intersecting a wellbore in order to understand the hydrologic behavior of fractured rocks. Often inflow from these fractures into the wellbore is at very low rates. A new procedure has been proposed and a corresponding method of analysis developed to obtain fracture inflow parameters from a time sequence of electric conductivity logs of the borehole fluid. The present report is a companion document to NTB--88-13 giving the details of equations and computer code used to compute borehole fluid conductivity distributions. Verification of the code used and a listing of the code are also given. (author) 9 refs., 5 figs., 7 tabs

  4. 'BACO' code: Cogeneration cycles heat balance; El programa BACO (Balance de Ciclos de Cogeneracion)

    Energy Technology Data Exchange (ETDEWEB)

    Huelamo Martinez, E; Conesa Lopez, P; Garcia Kilroy, P [Empresarios Agrupados, A.I.E., Madrid (Spain)

    1993-12-15

    This paper presents a code, developed by Empresarios Agrupados, sponsored by OCIDE, CSE and ENHER, that, with Electrical Utilities as final users, allows to make combined and cogeneration cycles technical-economical studies. (author)

  5. POPCYCLE: a computer code for calculating nuclear and fossil plant levelized life-cycle power costs

    International Nuclear Information System (INIS)

    Hardie, R.W.

    1982-02-01

    POPCYCLE, a computer code designed to calculate levelized life-cycle power costs for nuclear and fossil electrical generating plants is described. Included are (1) derivations of the equations and a discussion of the methodology used by POPCYCLE, (2) a description of the input required by the code, (3) a listing of the input for a sample case, and (4) the output for a sample case

  6. NeuCode Proteomics Reveals Bap1 Regulation of Metabolism

    Directory of Open Access Journals (Sweden)

    Joshua M. Baughman

    2016-07-01

    Full Text Available We introduce neutron-encoded (NeuCode amino acid labeling of mice as a strategy for multiplexed proteomic analysis in vivo. Using NeuCode, we characterize an inducible knockout mouse model of Bap1, a tumor suppressor and deubiquitinase whose in vivo roles outside of cancer are not well established. NeuCode proteomics revealed altered metabolic pathways following Bap1 deletion, including profound elevation of cholesterol biosynthetic machinery coincident with reduced expression of gluconeogenic and lipid homeostasis proteins in liver. Bap1 loss increased pancreatitis biomarkers and reduced expression of mitochondrial proteins. These alterations accompany a metabolic remodeling with hypoglycemia, hypercholesterolemia, hepatic lipid loss, and acinar cell degeneration. Liver-specific Bap1 null mice present with fully penetrant perinatal lethality, severe hypoglycemia, and hepatic lipid deficiency. This work reveals Bap1 as a metabolic regulator in liver and pancreas, and it establishes NeuCode as a reliable proteomic method for deciphering in vivo biology.

  7. Does photovoltaics reduce the environmental intensity of Swiss electrical power?

    International Nuclear Information System (INIS)

    Stucki, M.; Frischknecht, R.

    2010-01-01

    This article presents and discusses knowledge gained from current eco-balances made concerning electricity from solar cells. The use of photovoltaic systems in Switzerland, especially in the light of climate warming, as well as discussions on appropriate locations for the disposal of nuclear wastes are examined. The authors are of the opinion that current eco-balances can provide an objective basis for the development of qualified answers to such questions. The eco-balances for electricity generated by solar cells is discussed in detail. The development of photovoltaic technologies since 1992 is examined and scenarios for the period up to 2050 are discussed. Comparisons are made concerning solar power in Switzerland and Europe and the advantages of using solar power in Switzerland as a replacement for power from non-renewable resources in Europe are discussed

  8. The analysis of Taiwan's residential electricity demand under the electricity tariff policy

    Science.gov (United States)

    Chen, Po-Jui

    In October 2013, the Taiwan Power Company (Taipower), the monopolized state utility service in Taiwan, implemented an electricity tariff adjustment policy to reduce residential electricity demand. Using bi-monthly billing data from 6,932 electricity consumers, this study examine how consumers respond to an increase in electricity prices. This study employs an empirical approach that takes advantage of quasi-random variation over a period of time when household bills were affected by a change in electricity price. The study found that this price increase caused a 1.78% decline in residential electricity consumption, implying a price elasticity of -0.19 for summer-season months and -0.15 for non-summer-season months. The demand for electricity is therefore relatively inelastic, likely because it is hard for people to change their electricity consumption behavior in the short-term. The results of this study highlight that demand-side management cannot be the only lever used to address Taiwan's forecasted decrease in electricity supply.

  9. Application of startup/core management code system to YGN 3 startup testing

    International Nuclear Information System (INIS)

    Chi, Sung Goo; Hah, Yung Joon; Doo, Jin Yong; Kim, Dae Kyum

    1995-01-01

    YGN 3 is the first nuclear power plant in Korea to use the fixed incore detector system for startup testing and core management. The startup/core management code system was developed from existing ABB-C-E codes and applied for YGN 3 startup testing, especially for physics and CPC(Core Protection Calculator)/COLSS (Core Operating Limit Supervisory System) related testing. The startup/core management code system consists of startup codes which include the CEBASE, CECOR, CEFAST and CEDOPS, and startup data reduction codes which include FLOWRATE, COREPERF, CALMET, and VARTAV. These codes were implemented on an HP/Apollo model 9000 series 400 workstation at the YGN 3 site and successfully applied to startup testing and core management. The startup codes made a great contribution in upgrading the reliability of test results and reducing the test period by taking and analyzing core data automatically. The data reduction code saved the manpower and time for test data reduction and decreased the chance for error in the analysis. It is expected that this code system will make similar contributions for reducing the startup testing duration of YGN 4 and UCN3,4

  10. Current lead thermal analysis code 'CURRENT'

    International Nuclear Information System (INIS)

    Yamaguchi, Masahito; Tada, Eisuke; Shimamoto, Susumu; Hata, Kenichiro.

    1985-08-01

    Large gas-cooled current lead with the capacity more than 30 kA and 22 kV is required for superconducting toroidal and poloidal coils for fusion application. The current lead is used to carry electrical current from the power supply system at room temperature to the superconducting coil at 4 K. Accordingly, the thermal performance of the current lead is significantly important to determine the heat load requirements of the coil system at 4 K. Japan Atomic Energy Research Institute (JAERI) has being developed the large gas-cooled current leads with the optimum condition in which the heat load is around 1 W per 1 kA at 4 K. In order to design the current lead with the optimum thermal performances, JAERI developed thermal analysis code named as ''CURRENT'' which can theoretically calculate the optimum geometric shape and cooling conditions of the current lead. The basic equations and the instruction manual of the analysis code are described in this report. (author)

  11. High-Penetration Photovoltaics Standards and Codes Workshop, Denver, Colorado, May 20, 2010: Workshop Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Kroposki, B.; Basso, T.; Lynn, K.; Herig, C.; Bower, W.

    2010-09-01

    Effectively interconnecting high-level penetration of photovoltaic (PV) systems requires careful technical attention to ensuring compatibility with electric power systems. Standards, codes, and implementation have been cited as major impediments to widespread use of PV within electric power systems. On May 20, 2010, in Denver, Colorado, the National Renewable Energy Laboratory, in conjunction with the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), held a workshop to examine the key technical issues and barriers associated with high PV penetration levels with an emphasis on codes and standards. This workshop included building upon results of the High Penetration of Photovoltaic (PV) Systems into the Distribution Grid workshop held in Ontario California on February 24-25, 2009, and upon the stimulating presentations of the diverse stakeholder presentations.

  12. Evaluation Codes from an Affine Veriety Code Perspective

    DEFF Research Database (Denmark)

    Geil, Hans Olav

    2008-01-01

    Evaluation codes (also called order domain codes) are traditionally introduced as generalized one-point geometric Goppa codes. In the present paper we will give a new point of view on evaluation codes by introducing them instead as particular nice examples of affine variety codes. Our study...... includes a reformulation of the usual methods to estimate the minimum distances of evaluation codes into the setting of affine variety codes. Finally we describe the connection to the theory of one-pointgeometric Goppa codes. Contents 4.1 Introduction...... . . . . . . . . . . . . . . . . . . . . . . . 171 4.9 Codes form order domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 4.10 One-point geometric Goppa codes . . . . . . . . . . . . . . . . . . . . . . . . 176 4.11 Bibliographical Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 References...

  13. The NIMROD Code

    Science.gov (United States)

    Schnack, D. D.; Glasser, A. H.

    1996-11-01

    NIMROD is a new code system that is being developed for the analysis of modern fusion experiments. It is being designed from the beginning to make the maximum use of massively parallel computer architectures and computer graphics. The NIMROD physics kernel solves the three-dimensional, time-dependent two-fluid equations with neo-classical effects in toroidal geometry of arbitrary poloidal cross section. The NIMROD system also includes a pre-processor, a grid generator, and a post processor. User interaction with NIMROD is facilitated by a modern graphical user interface (GUI). The NIMROD project is using Quality Function Deployment (QFD) team management techniques to minimize re-engineering and reduce code development time. This paper gives an overview of the NIMROD project. Operation of the GUI is demonstrated, and the first results from the physics kernel are given.

  14. Modular Modeling System (MMS) code: a versatile power plant analysis package

    International Nuclear Information System (INIS)

    Divakaruni, S.M.; Wong, F.K.L.

    1987-01-01

    The basic version of the Modular Modeling System (MMS-01), a power plant systems analysis computer code jointly developed by the Nuclear Power and the Coal Combustion Systems Divisions of the Electric Power Research Institute (EPRI), has been released to the utility power industry in April 1983 at a code release workshop held in Charlotte, North Carolina. Since then, additional modules have been developed to analyze the Pressurized Water Reactors (PWRs) and the Boiling Water Reactors (BWRs) when the safety systems are activated. Also, a selected number of modules in the MMS-01 library have been modified to allow the code users more flexibility in constructing plant specific systems for analysis. These new PWR and BWR modules constitute the new MMS library, and it includes the modifications to the MMS-01 library. A year and half long extensive code qualification program of this new version of the MMS code at EPRI and the contractor sites, back by further code testing in an user group environment is culminating in the MMS-02 code release announcement seminar. At this seminar, the results of user group efforts and the code qualification program will be presented in a series of technical sessions. A total of forty-nine papers will be presented to describe the new code features and the code qualification efforts. For the sake of completion, an overview of the code is presented to include the history of the code development, description of the MMS code and its structure, utility engineers involvement in MMS-01 and MMS-02 validations, the enhancements made in the last 18 months to the code, and finally the perspective on the code future in the fossil and nuclear industry

  15. An Optimal Linear Coding for Index Coding Problem

    OpenAIRE

    Pezeshkpour, Pouya

    2015-01-01

    An optimal linear coding solution for index coding problem is established. Instead of network coding approach by focus on graph theoric and algebraic methods a linear coding program for solving both unicast and groupcast index coding problem is presented. The coding is proved to be the optimal solution from the linear perspective and can be easily utilize for any number of messages. The importance of this work is lying mostly on the usage of the presented coding in the groupcast index coding ...

  16. C code generation applied to nonlinear model predictive control for an artificial pancreas

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Jørgensen, John Bagterp

    2017-01-01

    This paper presents a method to generate C code from MATLAB code applied to a nonlinear model predictive control (NMPC) algorithm. The C code generation uses the MATLAB Coder Toolbox. It can drastically reduce the time required for development compared to a manual porting of code from MATLAB to C...

  17. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  18. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  19. Electric field simulation and measurement of a pulse line ion accelerator

    International Nuclear Information System (INIS)

    Shen Xiaokang; Zhang Zimin; Cao Shuchun; Zhao Hongwei; Zhao Quantang; Liu Ming; Jing Yi; Wang Bo; Shen Xiaoli

    2012-01-01

    An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix. (authors)

  20. The amendment of the Labour Code

    Directory of Open Access Journals (Sweden)

    Jana Mervartová

    2012-01-01

    Full Text Available The amendment of the Labour Code, No. 365/2011 Coll., effective as from 1st January 2012, brings some of fundamental changes in labour law. The amendment regulates relation between the Labour Code and the Civil Code; and is also formulates principles of labour law relations newly. The basic period by fixed-term contract of employment is extended and also frequency its conclusion is limited. The length of trial period and the amount of redundancy payment are graduated. An earlier legislative regulation which an employee is temporarily assign to work for different employer has been returned. The number of hours by agreement to perform work is increased. The monetary compensation by competitive clause is reduced. The other changes are realised in part of collective labour law. The authoress of article notifies of the most important changes. She compares new changes of the Labour Code and former legal system and she also evaluates their advantages and disadvantages. The main objective of changes ensures labour law relations to be more flexible. And it should motivate creation of new jobs opening by employers. Amended provisions are aimed to reduction expenses of employers under the reform of the public finances. Also changes are expected in the Labour Code in connection with the further new Civil Code.

  1. RCC-E: Design and construction rules for electrical equipment of PWR nuclear islands

    International Nuclear Information System (INIS)

    2016-01-01

    RCC-E describes the rules for designing, building and installing electrical and I and C systems and equipment for pressurized water reactors. The code was drafted in partnership with industry, engineering firms, manufacturers, building control firms and operators, and represents a collection of best practices in accordance with IAEA requirements and IEC standards. The code's scope covers: architecture and the associated systems, materials engineering and the qualification procedure for normal and accidental environmental conditions, facility engineering and management of common cause failures (electrical and I and C) and electromagnetic interference, testing and inspecting electrical characteristics, quality assurance requirements supplementing ISO 9001 and activity monitoring. Use: RCC-E has been used to build the following power plants: France's last 12 nuclear units (1,300 MWe (8) and 1,450 MWe (4)), 2 M310 reactors in Korea (2), 44 M310 (4), CPR-1000 (28), CPR-600 (6), HPR-1000 (4) and EPR (2) reactors in service or undergoing construction in China, 1 EPR reactor in France. RCC-E is used for maintenance operations in French power plants (58 units) and Chinese M310 and CPR-1000 power plants. RCC-E has been chosen for the construction of the EPR plants in Hinkley Point, UK. Contents of the 2016 edition of the RCC-E code: Volume 1 - General requirements and quality assurance; Volume 2 - Specification of requirements; Volume 3 - I and C systems; Volume 4 - Electrical systems; Volume 5 - Materials engineering; Volume 6 - Installation of electrical and I and C systems; Volume 7 - Inspection and test methods

  2. SUN-RAH: a nucleoelectric BWR university simulator based in reduced order models

    International Nuclear Information System (INIS)

    Morales S, J.B.; Lopez R, A.; Sanchez B, A.; Sanchez S, R.; Hernandez S, A.

    2003-01-01

    The development of a simulator that allows to represent the dynamics of a nucleo electric central, with nuclear reactor of the BWR type, using reduced order models is presented. These models present the characteristics defined by the dominant poles of the system (1) and most of those premature operation transitories in a power station can be reproduced with considerable fidelity if the models are identified with data of plant or references of a code of better estimate like RAMONA, TRAC (2) or RELAP. The models of the simulator are developments or own simplifications starting from the physical laws and retaining the main terms. This work describes the objective of the project and the general specifications of the University student of Nucleo electric simulator with Boiling Water Reactor type (SUN-RAH) as well as the finished parts that fundamentally are the nuclear reactor, the one of steam supply (NSSS), the plant balance (BOP), the main controllers of the plant and the implemented graphic interfaces. The pendent goals as well as the future developments and applications of SUN-RAH are described. (Author)

  3. Analysis of LH Launcher Arrays (Like the ITER One) Using the TOPLHA Code

    International Nuclear Information System (INIS)

    Maggiora, R.; Milanesio, D.; Vecchi, G.

    2009-01-01

    TOPLHA (Torino Polytechnic Lower Hybrid Antenna) code is an innovative tool for the 3D/1D simulation of Lower Hybrid (LH) antennas, i.e. accounting for realistic 3D waveguides geometry and for accurate 1D plasma models, and without restrictions on waveguide shape, including curvature. This tool provides a detailed performances prediction of any LH launcher, by computing the antenna scattering parameters, the current distribution, electric field maps and power spectra for any user-specified waveguide excitation. In addition, a fully parallelized and multi-cavity version of TOPLHA permits the analysis of large and complex waveguide arrays in a reasonable simulation time. A detailed analysis of the performances of the proposed ITER LH antenna geometry has been carried out, underlining the strong dependence of the antenna input parameters with respect to plasma conditions. A preliminary optimization of the antenna dimensions has also been accomplished. Electric current distribution on conductors, electric field distribution at the interface with plasma, and power spectra have been calculated as well. The analysis shows the strong capabilities of the TOPLHA code as a predictive tool and its usefulness to LH launcher arrays detailed design.

  4. A robust flexible-probabilistic programming method for planning municipal energy system with considering peak-electricity price and electric vehicle

    International Nuclear Information System (INIS)

    Yu, L.; Li, Y.P.; Huang, G.H.; An, C.J.

    2017-01-01

    Highlights: • A robust flexible probabilistic programming method is developed for planning MES. • Multiple uncertainties with various violations and satisfaction levels are examined. • Solutions of considering peak electricity prices and electric vehicles are analyzed. • RFPP-MES can better improve energy system reliability and abate pollutant emission. - Abstract: Effective electric power systems (EPS) planning with considering electricity price of 24-h time is indispensable in terms of load shifting, pollutant mitigation and energy demand-supply reliability as well as reducing electricity expense of end-users. In this study, a robust flexible probabilistic programming (RFPP) method is developed for planning municipal energy system (MES) with considering peak electricity prices (PEPs) and electric vehicles (EVs), where multiple uncertainties regarded as intervals, probability distributions and flexibilities as well as their combinations can be effectively reflected. The RFPP-MES model is then applied to planning Qingdao’s MES, where electrical load of 24-h time is simulated based on Monte Carlo. Results reveal that: (a) different time intervals lead to changes of energy supply patterns, the energy supply patterns would tend to the transition from self-supporting dominated (i.e. in valley hours) to outsourcing-dominated (i.e. in peak hours); (b) 15.9% of total imported electricity expense would be reduced compared to that without considering PEPs; (c) with considering EVs, the CO_2 emissions of Qingdao’s transportation could be reduced directly and the reduction rate would be 2.5%. Results can help decision makers improve energy supply patterns, reduce energy system costs and abate pollutant emissions as well as adjust end-users’ consumptions.

  5. Enabling Cognitive Load-Aware AR with Rateless Coding on a Wearable Network

    Directory of Open Access Journals (Sweden)

    R. Razavi

    2008-01-01

    Full Text Available Augmented reality (AR on a head-mounted display is conveniently supported by a wearable wireless network. If, in addition, the AR display is moderated to take account of the cognitive load of the wearer, then additional biosensors form part of the network. In this paper, the impact of these additional traffic sources is assessed. Rateless coding is proposed to not only protect the fragile encoded video stream from wireless noise and interference but also to reduce coding overhead. The paper proposes a block-based form of rateless channel coding in which the unit of coding is a block within a packet. The contribution of this paper is that it minimizes energy consumption by reducing the overhead from forward error correction (FEC, while error correction properties are conserved. Compared to simple packet-based rateless coding, with this form of block-based coding, data loss is reduced and energy efficiency is improved. Cross-layer organization of piggy-backed response blocks must take place in response to feedback, as detailed in the paper. Compared also to variants of its default FEC scheme, results from a Bluetooth (IEEE 802.15.1 wireless network show a consistent improvement in energy consumption, packet arrival latency, and video quality at the AR display.

  6. Electric treatment for hydrophilic ink deinking.

    Science.gov (United States)

    Du, Xiaotang; Hsieh, Jeffery S

    2017-09-01

    Hydrophilic inks have been widely used due to higher printing speed, competitive cost and being healthy non-organic solvents. However, they cause problems in both product quality and process runnability due to their hydrophilic surface wettability, strong negative surface charge and sub-micron size. Electric treatment was shown to be able to increase the ink sizes from 60 nm to 700 nm through electrocoagulation and electrophoresis. In addition, electric treatment assisted flotation could reduce effective residual ink concentration (ERIC) by 90 ppm, compared with only 20 ppm by traditional flotation. Furthermore, the effect of electric treatment alone on ink separation was investigated by two anode materials, graphite and stainless steel. Both of them could remove hydrophilic inks with less than 1% yield loss via electroflotation and electrophoresis. But graphite is a better material as the anode because graphite reduced ERIC by an additional 100 ppm. The yield loss of flotation following electric treatment was also lower by 17% if graphite was the anode material. The difference between the two electrode materials resulted from electrocoagulation and ink redeposition during electric treatment. An electric pretreatment-flotation-hyperwashing process was conducted to understand the deinking performance in conditions similar to a paper mill, and the ERIC was reduced from 950 ppm to less than 400 ppm.

  7. Noise-enhanced coding in phasic neuron spike trains.

    Science.gov (United States)

    Ly, Cheng; Doiron, Brent

    2017-01-01

    The stochastic nature of neuronal response has lead to conjectures about the impact of input fluctuations on the neural coding. For the most part, low pass membrane integration and spike threshold dynamics have been the primary features assumed in the transfer from synaptic input to output spiking. Phasic neurons are a common, but understudied, neuron class that are characterized by a subthreshold negative feedback that suppresses spike train responses to low frequency signals. Past work has shown that when a low frequency signal is accompanied by moderate intensity broadband noise, phasic neurons spike trains are well locked to the signal. We extend these results with a simple, reduced model of phasic activity that demonstrates that a non-Markovian spike train structure caused by the negative feedback produces a noise-enhanced coding. Further, this enhancement is sensitive to the timescales, as opposed to the intensity, of a driving signal. Reduced hazard function models show that noise-enhanced phasic codes are both novel and separate from classical stochastic resonance reported in non-phasic neurons. The general features of our theory suggest that noise-enhanced codes in excitable systems with subthreshold negative feedback are a particularly rich framework to study.

  8. Application of additive tariffs in the electricity sector

    International Nuclear Information System (INIS)

    Apolinario, I.; Felizardo, N.; Leite Garcia, A.; Oliveira, P.; Trindade, A.; Vasconcelos, J.; Verdelho, P.

    2004-01-01

    This paper presents and discusses a methodology for the calculation and application of tariffs in the electricity sector based on the principle of tariff additivity. It shows how such tariffs can reflect costs and assure the absence of cross subsidies between clients. The methodology presented was adopted in the Portuguese Tariff Code for electricity by the Portuguese Energy Regulator (ERSE). The work presented in this article reflects the experience acquired by ERSE during the preparation, discussion and implementation of that Code. Allowed revenues are determined separately for every regulated activity, assuring that there are no cross subsidies between activities. Additionally, the application of the tariff additivity principle assures the nonexistence of cross subsidies between consumers. Regulated tariffs applicable to end users of electricity are determined by summation, variable by variable, of the different activity tariffs in accordance with the services the costumer uses and in the proportion of that use. The corollary is that if the different activity tariffs are cost reflective and promote efficiency in resource allocation, the tariffs applicable to consumers (access tariffs or integral tariffs) will also reflect costs in the same manner. Therefore, besides economic efficiency, equity between non binding system consumers and binding system consumers is promoted. The examples presented in the article intend to show how additive tariffs reflect costs giving adequate economic price signals for the rational use of the networks and electric energy consumption

  9. Heat-electrical regeneration way to intensive energy saving in an electric arc furnaces

    Science.gov (United States)

    Kartavtcev, S.; Matveev, S.; Neshporenko, E.

    2018-03-01

    Energy saving in steel production is of great significance for its large economical scale of 1500 mil t/year and high-energy consumption. Steady trend of last years is an increase of steel production in electric arc furnaces (EAF) with a very high consumption of electricity up to 750 kWh/ton. The intention to reduce so much energy consumption they can reach by many ways. One of such way is a transforming heat energy of liquid steel to electricity and destine it to steel electric arc process. Under certain conditions, it may lead to “zero” consumption of electric power in the process. The development of these conditions leads to the formation of energy-efficient heat schemes, with a minimum electricity consumption from the external network.

  10. Electrical stimulation of paralyzed vibrissal muscles reduces endplate reinnervation and does not promote motor recovery after facial nerve repair in rats.

    Science.gov (United States)

    Sinis, Nektarios; Horn, Frauke; Genchev, Borislav; Skouras, Emmanouil; Merkel, Daniel; Angelova, Srebrina K; Kaidoglou, Katerina; Michael, Joern; Pavlov, Stoyan; Igelmund, Peter; Schaller, Hans-Eberhard; Irintchev, Andrey; Dunlop, Sarah A; Angelov, Doychin N

    2009-10-01

    The outcome of peripheral nerve injuries requiring surgical repair is poor. Recent work has suggested that electrical stimulation (ES) of denervated muscles could be beneficial. Here we tested whether ES has a positive influence on functional recovery after injury and surgical repair of the facial nerve. Outcomes at 2 months were compared to animals receiving sham stimulation (SS). Starting on the first day after end-to-end suture (facial-facial anastomosis), electrical stimulation (square 0.1 ms pulses at 5 Hz at an ex tempore established threshold amplitude of between 3.0 and 5.0V) was delivered to the vibrissal muscles for 5 min a day, 3 times a week. Restoration of vibrissal motor performance following ES or SS was evaluated using the video-based motion analysis and correlated with the degree of collateral axonal branching at the lesion site, the number of motor endplates in the target musculature and the quality of their reinnervation, i.e. the degree of mono- versus poly-innervation. Neither protocol reduced collateral branching. ES did not improve functional outcome, but rather reduced the number of innervated motor endplates to approximately one-fifth of normal values and failed to reduce the proportion of poly-innervated motor endplates. We conclude that ES is not beneficial for recovery of whisker function after facial nerve repair in rats.

  11. A Simultaneous and Continuous Excitation Method for High-Speed Electrical Impedance Tomography with Reduced Transients and Noise Sensitivity

    Directory of Open Access Journals (Sweden)

    Antoine Dupré

    2018-03-01

    Full Text Available This paper presents a concept for soft field tomographic scan of all the projections of electromagnetic waves emanating from an array of electrodes. Instead of the sequential excitation of all pairs of electrodes in the list of all projections, the new method present here consists of a single and continuous excitation. This excitation signal is the linear combination of the excitation signals in the projection set at different AC frequencies. The response to a given projection is discriminated by selecting the corresponding AC frequency component in the signal spectra of the digitally demodulated signals. The main advantage of this method is the suppression of transients after each projection, which is particularly problematic in electrical impedance tomography due to contact impedance phenomena and skin effect. The second benefit over the sequential scan method is the increased number of samples for each measurement for reduced noise sensitivity with digital demodulation. The third benefit is the increased temporal resolution in high-speed applications. The main drawback is the increased number of signal sources required (one per electrode. This paper focuses on electrical impedance tomography, based on earlier work by the authors. An experimental proof-of-concept using a simple 4-electrodes electrical impedance tomographic system is presented using simulations and laboratory data. The method presented here may be extended to other modalities (ultrasonic, microwave, optical, etc..

  12. Focus Group Research on the Implications of Adopting the Unified English Braille Code

    Science.gov (United States)

    Wetzel, Robin; Knowlton, Marie

    2006-01-01

    Five focus groups explored concerns about adopting the Unified English Braille Code. The consensus was that while the proposed changes to the literary braille code would be minor, those to the mathematics braille code would be much more extensive. The participants emphasized that "any code that reduces the number of individuals who can access…

  13. Evaluation of the Trac-PF1 code for simulating the Neptun reflooding experiment

    International Nuclear Information System (INIS)

    Pontedeiro, A.C.; Galetti, M.R.S.

    1991-01-01

    The present work presents an assessment of the TRAC-BF1 code using the results of the NEPTUN experiment which simulates the reflooding in a loss-of-coolant accident (LOCA) in a PWR. The NEPTUN experiment is composed of an array of electrically-heated tubes where the reflooding condition can be tested. Two types of tests results are presented and compared with the values obtained with the TRAC-BF1 code. From this comparison it is concluded that TRAC is suitable for verifying accident analysis. (author)

  14. UAV Mission Optimization through Hybrid-Electric Propulsion

    Science.gov (United States)

    Blackwelder, Philip Scott

    Hybrid-electric powertrain leverages the superior range of petrol based systems with the quiet and emission free benefits of electric propulsion. The major caveat to hybrid-electric powertrain in an airplane is that it is inherently heavier than conventional petroleum powertrain due mostly to the low energy density of battery technology. The first goal of this research is to develop mission planning code to match powertrain components for a small-scale unmanned aerial vehicle (UAV) to complete a standard surveillance mission within a set of user input parameters. The second goal is to promote low acoustic profile loitering through mid-flight engine starting. The two means by which midmission engine starting will be addressed is through reverse thrust from the propeller and a servo actuated gear to couple and decouple the engine and motor. The mission planning code calculates the power required to complete a mission and assists the user in sourcing powertrain components including the propeller, motor, battery, motor controller, engine and fuel. Reverse thrust engine starting involves characterizing an off the shelf variable pitch propeller and using its torque coefficient to calculate the advance ratio required to provide sufficient torque and speed to start an engine. Geared engine starting works like the starter in a conventional automobile. A servo actuated gear will couple the motor to the engine to start it and decouple once the engine has started. Reverse thrust engine starting was unsuccessful due to limitations of available off the shelf variable pitch propellers. However, reverse thrust engine starting could be realized through a custom larger diameter propeller. Geared engine starting was a success, though the system was unable to run fully as intended. Due to counter-clockwise crank rotation of the engine and the right-hand threads on the crankshaft, cranking the engine resulted in the nut securing the engine starter gear to back off as the engine cranked

  15. Fast decoding algorithms for geometric coded apertures

    International Nuclear Information System (INIS)

    Byard, Kevin

    2015-01-01

    Fast decoding algorithms are described for the class of coded aperture designs known as geometric coded apertures which were introduced by Gourlay and Stephen. When compared to the direct decoding method, the algorithms significantly reduce the number of calculations required when performing the decoding for these apertures and hence speed up the decoding process. Experimental tests confirm the efficacy of these fast algorithms, demonstrating a speed up of approximately two to three orders of magnitude over direct decoding.

  16. Intraoperative hemidiaphragm electrical stimulation reduces oxidative stress and upregulates autophagy in surgery patients undergoing mechanical ventilation: exploratory study

    Directory of Open Access Journals (Sweden)

    Robert T. Mankowski

    2016-10-01

    Full Text Available Abstract Background Mechanical ventilation (MV during a cardio-thoracic surgery contributes to diaphragm muscle dysfunction that impairs weaning and can lead to the ventilator- induced diaphragm dysfunction. Especially, it is critical in older adults who have lower muscle reparative capacity following MV. Reports have shown that the intraoperative intermittent hemidiaphragm electrical stimulation can maintain and/or improve post-surgery diaphragm function. In particular, from a molecular point of view, intermittent electrical stimulation (ES may reduce oxidative stress and increase regulatory autophagy levels, and therefore improve diaphragm function in animal studies. We have recently shown in humans that intraoperative ES attenuates mitochondrial dysfunction and force decline in single diaphragm muscle fibers. The aim of this study was to investigate an effect of ES on oxidative stress, antioxidant status and autophagy biomarker levels in the human diaphragm during surgery. Methods One phrenic nerve was simulated with an external cardiac pacer in operated older subjects (62.4 ± 12.9 years (n = 8 during the surgery. The patients received 30 pulses per min every 30 min. The muscle biopsy was collected from both hemidiaphragms and frozen for further analyses. 4-hydroxynonenal (4-HNE, an oxidative stress marker, and autophagy marker levels (Beclin-1 and the ratio of microtubule-associated protein light chain 3, I and II-LC3 II/I protein concentrations were detected by the Western Blot technique. Antioxidant enzymatic activity copper-zinc (CuZnSOD and manganese (MnSOD superoxide dismutase were analyzed. Results Levels of lipid peroxidation (4-HNE were significantly lower in the stimulated side (p  0.05. Additionally, the protein concentrations of Beclin-1 and the LC3 II/I ratio were higher in the stimulated side (p < 0.05. Conclusion These results suggest that the intraoperative electrical stimulation decreases oxidative stress levels

  17. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  18. A long-term, integrated impact assessment of alternative building energy code scenarios in China

    International Nuclear Information System (INIS)

    Yu, Sha; Eom, Jiyong; Evans, Meredydd; Clarke, Leon

    2014-01-01

    China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO 2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, is developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13–22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement. - Highlights: • We assessed long-term impacts of building codes and climate policy using GCAM. • Building energy codes would reduce Chinese building energy use by 13–22%. • The impacts of codes on building energy use vary by climate region and sub-sector

  19. Systematic Luby Transform codes as incremental redundancy scheme

    CSIR Research Space (South Africa)

    Grobler, TL

    2011-09-01

    Full Text Available Transform Codes as Incremental Redundancy Scheme T. L. Grobler y, E. R. Ackermann y, J. C. Olivier y and A. J. van Zylz Department of Electrical, Electronic and Computer Engineering University of Pretoria, Pretoria 0002, South Africa Email: trienkog...@gmail.com, etienne.ackermann@ieee.org yDefence, Peace, Safety and Security (DPSS) Council for Scientific and Industrial Research (CSIR), Pretoria 0001, South Africa zDepartment of Mathematics and Applied Mathematics University of Pretoria, Pretoria 0002, South...

  20. Energy-Efficient Cluster Based Routing Protocol in Mobile Ad Hoc Networks Using Network Coding

    OpenAIRE

    Srinivas Kanakala; Venugopal Reddy Ananthula; Prashanthi Vempaty

    2014-01-01

    In mobile ad hoc networks, all nodes are energy constrained. In such situations, it is important to reduce energy consumption. In this paper, we consider the issues of energy efficient communication in MANETs using network coding. Network coding is an effective method to improve the performance of wireless networks. COPE protocol implements network coding concept to reduce number of transmissions by mixing the packets at intermediate nodes. We incorporate COPE into cluster based routing proto...

  1. Improved Intra-coding Methods for H.264/AVC

    Directory of Open Access Journals (Sweden)

    Li Song

    2009-01-01

    Full Text Available The H.264/AVC design adopts a multidirectional spatial prediction model to reduce spatial redundancy, where neighboring pixels are used as a prediction for the samples in a data block to be encoded. In this paper, a recursive prediction scheme and an enhanced (block-matching algorithm BMA prediction scheme are designed and integrated into the state-of-the-art H.264/AVC framework to provide a new intra coding model. Extensive experiments demonstrate that the coding efficiency can be on average increased by 0.27 dB with comparison to the performance of the conventional H.264 coding model.

  2. Endocannabinoid release modulates electrical coupling between CCK cells connected via chemical and electrical synapses in CA1

    Directory of Open Access Journals (Sweden)

    Jonathan eIball

    2011-11-01

    Full Text Available Electrical coupling between some subclasses of interneurons is thought to promote coordinated firing that generates rhythmic synchronous activity in cortical regions. Synaptic activity of cholesystokinin (CCK interneurons which co-express cannbinoid type-1 (CB1 receptors are powerful modulators of network activity via the actions of endocannabinoids. We investigated the modulatory actions of endocannabinoids between chemically and electrically connected synapses of CCK cells using paired whole-cell recordings combined with biocytin and double immunofluorescence labelling in acute slices of rat hippocampus at P18-20 days. CA1 stratum radiatum CCK Schaffer collateral associated (SCA cells were coupled electrically with each other as well as CCK basket cells and CCK cells with axonal projections expanding to dentate gyrus. Approximately 50% of electrically coupled cells received facilitating, asynchronously released IPSPs that curtailed the steady-state coupling coefficient by 57%. Tonic CB1 receptor activity which reduces inhibition enhanced electrical coupling between cells that were connected via chemical and electrical synapses. Blocking CB1 receptors with antagonist, AM-251 (5M resulted in the synchronized release of larger IPSPs and this enhanced inhibition further reduced the steady-state coupling coefficient by 85%. Depolarization induced suppression of inhibition (DSI, maintained the asynchronicity of IPSP latency, but reduced IPSP amplitudes by 95% and enhanced the steady-state coupling coefficient by 104% and IPSP duration by 200%. However, DSI did not did not enhance electrical coupling at purely electrical synapses. These data suggest that different morphological subclasses of CCK interneurons are interconnected via gap junctions. The synergy between the chemical and electrical coupling between CCK cells probably plays a role in activity-dependent endocannabinoid modulation of rhythmic synchronization.

  3. Terahertz wave manipulation based on multi-bit coding artificial electromagnetic surfaces

    Science.gov (United States)

    Li, Jiu-Sheng; Zhao, Ze-Jiang; Yao, Jian-Quan

    2018-05-01

    A polarization insensitive multi-bit coding artificial electromagnetic surface is proposed for terahertz wave manipulation. The coding artificial electromagnetic surfaces composed of four-arrow-shaped particles with certain coding sequences can generate multi-bit coding in the terahertz frequencies and manipulate the reflected terahertz waves to the numerous directions by using of different coding distributions. Furthermore, we demonstrate that our coding artificial electromagnetic surfaces have strong abilities to reduce the radar cross section with polarization insensitive for TE and TM incident terahertz waves as well as linear-polarized and circular-polarized terahertz waves. This work offers an effectively strategy to realize more powerful manipulation of terahertz wave.

  4. Locally Minimum Storage Regenerating Codes in Distributed Cloud Storage Systems

    Institute of Scientific and Technical Information of China (English)

    Jing Wang; Wei Luo; Wei Liang; Xiangyang Liu; Xiaodai Dong

    2017-01-01

    In distributed cloud storage sys-tems, inevitably there exist multiple node fail-ures at the same time. The existing methods of regenerating codes, including minimum storage regenerating (MSR) codes and mini-mum bandwidth regenerating (MBR) codes, are mainly to repair one single or several failed nodes, unable to meet the repair need of distributed cloud storage systems. In this paper, we present locally minimum storage re-generating (LMSR) codes to recover multiple failed nodes at the same time. Specifically, the nodes in distributed cloud storage systems are divided into multiple local groups, and in each local group (4, 2) or (5, 3) MSR codes are constructed. Moreover, the grouping method of storage nodes and the repairing process of failed nodes in local groups are studied. The-oretical analysis shows that LMSR codes can achieve the same storage overhead as MSR codes. Furthermore, we verify by means of simulation that, compared with MSR codes, LMSR codes can reduce the repair bandwidth and disk I/O overhead effectively.

  5. Grid requirements applicable to future NPPs in the new European Electricity Framework

    International Nuclear Information System (INIS)

    Beato Castro, D.; Padill, C. M.

    2000-01-01

    With a view to keeping nuclear energy as an option for future power generation in a competitive market and taking advantage of the current operating experience, a group of European electric utilities have come together to define common requirements for the design and supply of future Light Water Reactor (LWR) plants connected to the electrical system. These requirements, defined with the aim of standardizing and adapting design to the conditions of the new electricity framework, are being included in the European Utility Requirements (EUR) document. Although there are different types of power plants operating appropriately in large electrical systems, the idea is to find the minimum requirements that will allow growth of this type of energy in the European electricity industry without reducing quality, safety and reliability of interconnected electrical systems. It is therefore necessary to take into account the features of the existing power systems and the operating characteristics and design of nuclear power plants so as to harmonize their respective technical peculiarities in the framework of the deregulated electricity sector. The definition of these grid requirements is based primarily on the operating conditions of the Union pour la Coordination de la Production et le Transport de L'Electricite (UCPTE) grid and takes into account the current Grid Code of the main European countries, for the forthcoming Issue C. This paper sets outs the most relevant aspects of the grid requirements, included in Chapter 2.3 of the EUR document Grid Requirements, Issue B, for the connection of future nuclear power plants in the European electricity system, and others that are being considered in the preparation of the new issue of the document that will take into account the deregulated electricity market situation and deal with the following aspects: General characteristics. Operation of a plant under normal grid conditions. Operation of a plant under disturbed grid

  6. Rate-adaptive BCH codes for distributed source coding

    DEFF Research Database (Denmark)

    Salmistraro, Matteo; Larsen, Knud J.; Forchhammer, Søren

    2013-01-01

    This paper considers Bose-Chaudhuri-Hocquenghem (BCH) codes for distributed source coding. A feedback channel is employed to adapt the rate of the code during the decoding process. The focus is on codes with short block lengths for independently coding a binary source X and decoding it given its...... strategies for improving the reliability of the decoded result are analyzed, and methods for estimating the performance are proposed. In the analysis, noiseless feedback and noiseless communication are assumed. Simulation results show that rate-adaptive BCH codes achieve better performance than low...... correlated side information Y. The proposed codes have been analyzed in a high-correlation scenario, where the marginal probability of each symbol, Xi in X, given Y is highly skewed (unbalanced). Rate-adaptive BCH codes are presented and applied to distributed source coding. Adaptive and fixed checking...

  7. Self-complementary circular codes in coding theory.

    Science.gov (United States)

    Fimmel, Elena; Michel, Christian J; Starman, Martin; Strüngmann, Lutz

    2018-04-01

    Self-complementary circular codes are involved in pairing genetic processes. A maximal [Formula: see text] self-complementary circular code X of trinucleotides was identified in genes of bacteria, archaea, eukaryotes, plasmids and viruses (Michel in Life 7(20):1-16 2017, J Theor Biol 380:156-177, 2015; Arquès and Michel in J Theor Biol 182:45-58 1996). In this paper, self-complementary circular codes are investigated using the graph theory approach recently formulated in Fimmel et al. (Philos Trans R Soc A 374:20150058, 2016). A directed graph [Formula: see text] associated with any code X mirrors the properties of the code. In the present paper, we demonstrate a necessary condition for the self-complementarity of an arbitrary code X in terms of the graph theory. The same condition has been proven to be sufficient for codes which are circular and of large size [Formula: see text] trinucleotides, in particular for maximal circular codes ([Formula: see text] trinucleotides). For codes of small-size [Formula: see text] trinucleotides, some very rare counterexamples have been constructed. Furthermore, the length and the structure of the longest paths in the graphs associated with the self-complementary circular codes are investigated. It has been proven that the longest paths in such graphs determine the reading frame for the self-complementary circular codes. By applying this result, the reading frame in any arbitrary sequence of trinucleotides is retrieved after at most 15 nucleotides, i.e., 5 consecutive trinucleotides, from the circular code X identified in genes. Thus, an X motif of a length of at least 15 nucleotides in an arbitrary sequence of trinucleotides (not necessarily all of them belonging to X) uniquely defines the reading (correct) frame, an important criterion for analyzing the X motifs in genes in the future.

  8. Diagonal Eigenvalue Unity (DEU) code for spectral amplitude coding-optical code division multiple access

    Science.gov (United States)

    Ahmed, Hassan Yousif; Nisar, K. S.

    2013-08-01

    Code with ideal in-phase cross correlation (CC) and practical code length to support high number of users are required in spectral amplitude coding-optical code division multiple access (SAC-OCDMA) systems. SAC systems are getting more attractive in the field of OCDMA because of its ability to eliminate the influence of multiple access interference (MAI) and also suppress the effect of phase induced intensity noise (PIIN). In this paper, we have proposed new Diagonal Eigenvalue Unity (DEU) code families with ideal in-phase CC based on Jordan block matrix with simple algebraic ways. Four sets of DEU code families based on the code weight W and number of users N for the combination (even, even), (even, odd), (odd, odd) and (odd, even) are constructed. This combination gives DEU code more flexibility in selection of code weight and number of users. These features made this code a compelling candidate for future optical communication systems. Numerical results show that the proposed DEU system outperforms reported codes. In addition, simulation results taken from a commercial optical systems simulator, Virtual Photonic Instrument (VPI™) shown that, using point to multipoint transmission in passive optical network (PON), DEU has better performance and could support long span with high data rate.

  9. Model Design on Emergency Power Supply of Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Yuanliang Zhao

    2017-01-01

    Full Text Available According to the mobile storage characteristic of electric vehicles, an emergency power supply model about the electric vehicles is presented through analyzing its storage characteristic. The model can ensure important consumer loss minimization during power failure or emergency and can make electric vehicles cost minimization about running, scheduling, and vindicating. In view of the random dispersion feature in one area, an emergency power supply scheme using the electric vehicles is designed based on the K-means algorithm. The purpose is to improve the electric vehicles initiative gathering ability and reduce the electric vehicles gathering time. The study can reduce the number of other emergency power supply equipment and improve the urban electricity reliability.

  10. List Decoding of Matrix-Product Codes from nested codes: an application to Quasi-Cyclic codes

    DEFF Research Database (Denmark)

    Hernando, Fernando; Høholdt, Tom; Ruano, Diego

    2012-01-01

    A list decoding algorithm for matrix-product codes is provided when $C_1,..., C_s$ are nested linear codes and $A$ is a non-singular by columns matrix. We estimate the probability of getting more than one codeword as output when the constituent codes are Reed-Solomon codes. We extend this list...... decoding algorithm for matrix-product codes with polynomial units, which are quasi-cyclic codes. Furthermore, it allows us to consider unique decoding for matrix-product codes with polynomial units....

  11. Lightning protection design of nuclear power plants. KTA safety code, version 6/99

    International Nuclear Information System (INIS)

    1999-06-01

    This KTA safety code does not cover calculation methods for determination of lightning-induced voltage inputs to control room systems within the reactor building, as the literature presents a variety of applicable methods, which however cannot be directly applied to any power plant, due to the great diversity of geometries of the electrical systems and control room systems in nuclear power plants. Compliance with the design requirements of this safety code for shielding of buildings, and installation and shielding of cables, can be considered to offer the appropriate protection. (orig./CB) [de

  12. Electrically Conductive Anodized Aluminum Surfaces

    Science.gov (United States)

    Nguyen, Trung Hung

    2006-01-01

    Anodized aluminum components can be treated to make them sufficiently electrically conductive to suppress discharges of static electricity. The treatment was conceived as a means of preventing static electric discharges on exterior satin-anodized aluminum (SAA) surfaces of spacecraft without adversely affecting the thermal-control/optical properties of the SAA and without need to apply electrically conductive paints, which eventually peel off in the harsh environment of outer space. The treatment can also be used to impart electrical conductivity to anodized housings of computers, medical electronic instruments, telephoneexchange equipment, and other terrestrial electronic equipment vulnerable to electrostatic discharge. The electrical resistivity of a typical anodized aluminum surface layer lies between 10(exp 11) and 10(exp 13) Omega-cm. To suppress electrostatic discharge, it is necessary to reduce the electrical resistivity significantly - preferably to anodized surface becomes covered and the pores in the surface filled with a transparent, electrically conductive metal oxide nanocomposite. Filling the pores with the nanocomposite reduces the transverse electrical resistivity and, in the original intended outer-space application, the exterior covering portion of the nanocomposite would afford the requisite electrical contact with the outer-space plasma. The electrical resistivity of the nanocomposite can be tailored to a value between 10(exp 7) and 10(exp 12) Omega-cm. Unlike electrically conductive paint, the nanocomposite becomes an integral part of the anodized aluminum substrate, without need for adhesive bonding material and without risk of subsequent peeling. The electrodeposition process is compatible with commercial anodizing production lines. At present, the electronics industry uses expensive, exotic, electrostaticdischarge- suppressing finishes: examples include silver impregnated anodized, black electroless nickel, black chrome, and black copper. In

  13. Coding Partitions

    Directory of Open Access Journals (Sweden)

    Fabio Burderi

    2007-05-01

    Full Text Available Motivated by the study of decipherability conditions for codes weaker than Unique Decipherability (UD, we introduce the notion of coding partition. Such a notion generalizes that of UD code and, for codes that are not UD, allows to recover the ``unique decipherability" at the level of the classes of the partition. By tacking into account the natural order between the partitions, we define the characteristic partition of a code X as the finest coding partition of X. This leads to introduce the canonical decomposition of a code in at most one unambiguouscomponent and other (if any totally ambiguouscomponents. In the case the code is finite, we give an algorithm for computing its canonical partition. This, in particular, allows to decide whether a given partition of a finite code X is a coding partition. This last problem is then approached in the case the code is a rational set. We prove its decidability under the hypothesis that the partition contains a finite number of classes and each class is a rational set. Moreover we conjecture that the canonical partition satisfies such a hypothesis. Finally we consider also some relationships between coding partitions and varieties of codes.

  14. Implementing particle-in-cell plasma simulation code on the BBN TC2000

    International Nuclear Information System (INIS)

    Sturtevant, J.E.; Maccabe, A.B.

    1990-01-01

    The BBN TC2000 is a multiple instruction, multiple data (MIMD) machine that combines a physically distributed memory with a logically shared memory programming environment using the unique Butterfly switch. Particle-In-Cell (PIC) plasma simulations model the interaction of charged particles with electric and magnetic fields. This paper describes the implementation of both a 1-D electrostatic and a 2 1/2-D electromagnetic PIC (particle-in-cell) plasma simulation code on a BBN TC2000. Performance is compared to implementations of the same code on the shared memory Sequent Balance and distributed memory Intel iPSC hypercube

  15. Etiology of work-related electrical injuries: a narrative analysis of workers' compensation claims.

    Science.gov (United States)

    Lombardi, David A; Matz, Simon; Brennan, Melanye J; Smith, Gordon S; Courtney, Theodore K

    2009-10-01

    The purpose of this study was to provide new insight into the etiology of primarily nonfatal, work-related electrical injuries. We developed a multistage, case-selection algorithm to identify electrical-related injuries from workers' compensation claims and a customized coding taxonomy to identify pre-injury circumstances. Workers' compensation claims routinely collected over a 1-year period from a large U.S. insurance provider were used to identify electrical-related injuries using an algorithm that evaluated: coded injury cause information, nature of injury, "accident" description, and injury description narratives. Concurrently, a customized coding taxonomy for these narratives was developed to abstract the activity, source, initiating process, mechanism, vector, and voltage. Among the 586,567 reported claims during 2002, electrical-related injuries accounted for 1283 (0.22%) of nonfatal claims and 15 fatalities (1.2% of electrical). Most (72.3%) were male, average age of 36, working in services (33.4%), manufacturing (24.7%), retail trade (17.3%), and construction (7.2%). Body part(s) injured most often were the hands, fingers, or wrist (34.9%); multiple body parts/systems (25.0%); lower/upper arm; elbow; shoulder, and upper extremities (19.2%). The leading activities were conducting manual tasks (55.1%); working with machinery, appliances, or equipment; working with electrical wire; and operating powered or nonpowered hand tools. Primary injury sources were appliances and office equipment (24.4%); wires, cables/cords (18.0%); machines and other equipment (11.8%); fixtures, bulbs, and switches (10.4%); and lightning (4.3%). No vector was identified in 85% of cases. and the work process was initiated by others in less than 1% of cases. Injury narratives provide valuable information to overcome some of the limitations of precoded data, more specially for identifying additional injury cases and in supplementing traditional epidemiologic data for further

  16. Combinatorial neural codes from a mathematical coding theory perspective.

    Science.gov (United States)

    Curto, Carina; Itskov, Vladimir; Morrison, Katherine; Roth, Zachary; Walker, Judy L

    2013-07-01

    Shannon's seminal 1948 work gave rise to two distinct areas of research: information theory and mathematical coding theory. While information theory has had a strong influence on theoretical neuroscience, ideas from mathematical coding theory have received considerably less attention. Here we take a new look at combinatorial neural codes from a mathematical coding theory perspective, examining the error correction capabilities of familiar receptive field codes (RF codes). We find, perhaps surprisingly, that the high levels of redundancy present in these codes do not support accurate error correction, although the error-correcting performance of receptive field codes catches up to that of random comparison codes when a small tolerance to error is introduced. However, receptive field codes are good at reflecting distances between represented stimuli, while the random comparison codes are not. We suggest that a compromise in error-correcting capability may be a necessary price to pay for a neural code whose structure serves not only error correction, but must also reflect relationships between stimuli.

  17. The Ontario Energy Board`s draft standard supply service code: effects on air quality

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J.; Bjorkquist, S. [Ontario Clean Air Alliance, Toronto, ON (Canada)

    1999-06-29

    The Ontario Clean Air Alliance (OCAA), a coalition of 67 organizations, takes issue with the Ontario Energy Board`s draft document `Standard Supply Service Code`, particularly sections 2.2.2. and 2.5.2 which they claim are not in the public interest unless the Ontario government implements the OCAA`s recommended emission caps. The alliance is of the view that without strict new environmental regulations the proposed Code would encourage the use of coal for electricity generation. Public health, the environment, consumer interests, job creation and promotion of a competitive electricity market would all be jeopardized by this development, the alliance states. The argument is supported by extensive reference to the Final Report of the Ontario Market Design Committee (MDC) which also emphasized the importance of combining the introduction of competition with appropriate environmental regulations, singling out the emission cap and trade program, and recommending that it be launched concurrently with the electricity market opening for competition. The view of the MDC was that public support for restructuring would not be forthcoming in the absence of regulatory measures to control power plant emissions. 25 refs.

  18. An overview of the major changes in the 2002 APA Ethics Code.

    Science.gov (United States)

    Knapp, Samuel; VandeCreek, Leon

    2003-06-01

    This article summarizes the major changes that were made to the 2002 Ethical Principles and Code of Conduct of the American Psychological Association. The 2002 Ethics Code retains the general format of the 1992 Ethics Code and does not radically alter the obligations of psychologists. One goal of the Ethics Committee Task Force was to reduce the potential of the Ethics Code to be used to unnecessarily punish psychologists. In addition, the revised Ethics Code expresses greater sensitivity to the needs of cultural and linguistic minorities and students. Shortcomings of the 2002 Ethics Code are discussed.

  19. Generation of Efficient High-Level Hardware Code from Dataflow Programs

    OpenAIRE

    Siret , Nicolas; Wipliez , Matthieu; Nezan , Jean François; Palumbo , Francesca

    2012-01-01

    High-level synthesis (HLS) aims at reducing the time-to-market by providing an automated design process that interprets and compiles high-level abstraction programs into hardware. However, HLS tools still face limitations regarding the performance of the generated code, due to the difficulties of compiling input imperative languages into efficient hardware code. Moreover the hardware code generated by the HLS tools is usually target-dependant and at a low level of abstraction (i.e. gate-level...

  20. Coding efficiency of AVS 2.0 for CBAC and CABAC engines

    Science.gov (United States)

    Cui, Jing; Choi, Youngkyu; Chae, Soo-Ik

    2015-12-01

    In this paper we compare the coding efficiency of AVS 2.0[1] for engines of the Context-based Binary Arithmetic Coding (CBAC)[2] in the AVS 2.0 and the Context-Adaptive Binary Arithmetic Coder (CABAC)[3] in the HEVC[4]. For fair comparison, the CABAC is embedded in the reference code RD10.1 because the CBAC is in the HEVC in our previous work[5]. The rate estimation table is employed only for RDOQ in the RD code. To reduce the computation complexity of the video encoder, therefore we modified the RD code so that the rate estimation table is employed for all RDO decision. Furthermore, we also simplify the complexity of rate estimation table by reducing the bit depth of its fractional part to 2 from 8. The simulation result shows that the CABAC has the BD-rate loss of about 0.7% compared to the CBAC. It seems that the CBAC is a little more efficient than that the CABAC in the AVS 2.0.

  1. Optimization of the particle pusher in a diode simulation code

    International Nuclear Information System (INIS)

    Theimer, M.M.; Quintenz, J.P.

    1979-09-01

    The particle pusher in Sandia's particle-in-cell diode simulation code has been rewritten to reduce the required run time of a typical simulation. The resulting new version of the code has been found to run up to three times as fast as the original with comparable accuracy. The cost of this optimization was an increase in storage requirements of about 15%. The new version has also been written to run efficiently on a CRAY-1 computing system. Steps taken to affect this reduced run time are described. Various test cases are detailed

  2. The role of nuclear energy meeting electricity needs in Africa

    International Nuclear Information System (INIS)

    Rising, R.

    2017-01-01

    Demand for electricity has risen dramatically regardless of economic shocks while accelerating rise in world electricity consumption. Decarbonizing electricity generation - need for low life cycle emissions: Nuclear energy is among the best and makes quick, lasting decarbonization possible. Harmonized regulatory processes: Enhance standardization, harmonize and update global codes and standards. Nuclear is regulated, financed and managed outside of normal protocols without an expansion of nuclear, many economies will fall short of their net mid-century carbon dioxide emission goal and society will fall short of the 2-degree scenario. Timely licensing of new technologies. In effective safety paradigm it good to embrace a holistic approach to society risks from electricity generation so that health and environmental benefits of all sources are maximized

  3. Software Certification - Coding, Code, and Coders

    Science.gov (United States)

    Havelund, Klaus; Holzmann, Gerard J.

    2011-01-01

    We describe a certification approach for software development that has been adopted at our organization. JPL develops robotic spacecraft for the exploration of the solar system. The flight software that controls these spacecraft is considered to be mission critical. We argue that the goal of a software certification process cannot be the development of "perfect" software, i.e., software that can be formally proven to be correct under all imaginable and unimaginable circumstances. More realistically, the goal is to guarantee a software development process that is conducted by knowledgeable engineers, who follow generally accepted procedures to control known risks, while meeting agreed upon standards of workmanship. We target three specific issues that must be addressed in such a certification procedure: the coding process, the code that is developed, and the skills of the coders. The coding process is driven by standards (e.g., a coding standard) and tools. The code is mechanically checked against the standard with the help of state-of-the-art static source code analyzers. The coders, finally, are certified in on-site training courses that include formal exams.

  4. Endocannabinoid Release Modulates Electrical Coupling between CCK Cells Connected via Chemical and Electrical Synapses in CA1

    Science.gov (United States)

    Iball, Jonathan; Ali, Afia B.

    2011-01-01

    Electrical coupling between some subclasses of interneurons is thought to promote coordinated firing that generates rhythmic synchronous activity in cortical regions. Synaptic activity of cholecystokinin (CCK) interneurons which co-express cannabinoid type-1 (CB1) receptors are powerful modulators of network activity via the actions of endocannabinoids. We investigated the modulatory actions of endocannabinoids between chemically and electrically connected synapses of CCK cells using paired whole-cell recordings combined with biocytin and double immunofluorescence labeling in acute slices of rat hippocampus at P18–20 days. CA1 stratum radiatum CCK Schaffer collateral-associated cells were coupled electrically with each other as well as CCK basket cells and CCK cells with axonal projections expanding to dentate gyrus. Approximately 50% of electrically coupled cells received facilitating, asynchronously released inhibitory postsynaptic potential (IPSPs) that curtailed the steady-state coupling coefficient by 57%. Tonic CB1 receptor activity which reduces inhibition enhanced electrical coupling between cells that were connected via chemical and electrical synapses. Blocking CB1 receptors with antagonist, AM-251 (5 μM) resulted in the synchronized release of larger IPSPs and this enhanced inhibition further reduced the steady-state coupling coefficient by 85%. Depolarization induced suppression of inhibition (DSI), maintained the asynchronicity of IPSP latency, but reduced IPSP amplitudes by 95% and enhanced the steady-state coupling coefficient by 104% and IPSP duration by 200%. However, DSI did not did not enhance electrical coupling at purely electrical synapses. These data suggest that different morphological subclasses of CCK interneurons are interconnected via gap junctions. The synergy between the chemical and electrical coupling between CCK cells probably plays a role in activity-dependent endocannabinoid modulation of rhythmic synchronization. PMID

  5. Development of an integrated thermal-hydraulics capability incorporating RELAP5 and PANTHER neutronics code

    Energy Technology Data Exchange (ETDEWEB)

    Page, R.; Jones, J.R.

    1997-07-01

    Ensuring that safety analysis needs are met in the future is likely to lead to the development of new codes and the further development of existing codes. It is therefore advantageous to define standards for data interfaces and to develop software interfacing techniques which can readily accommodate changes when they are made. Defining interface standards is beneficial but is necessarily restricted in application if future requirements are not known in detail. Code interfacing methods are of particular relevance with the move towards automatic grid frequency response operation where the integration of plant dynamic, core follow and fault study calculation tools is considered advantageous. This paper describes the background and features of a new code TALINK (Transient Analysis code LINKage program) used to provide a flexible interface to link the RELAP5 thermal hydraulics code with the PANTHER neutron kinetics and the SIBDYM whole plant dynamic modelling codes used by Nuclear Electric. The complete package enables the codes to be executed in parallel and provides an integrated whole plant thermal-hydraulics and neutron kinetics model. In addition the paper discusses the capabilities and pedigree of the component codes used to form the integrated transient analysis package and the details of the calculation of a postulated Sizewell `B` Loss of offsite power fault transient.

  6. Development of an integrated thermal-hydraulics capability incorporating RELAP5 and PANTHER neutronics code

    International Nuclear Information System (INIS)

    Page, R.; Jones, J.R.

    1997-01-01

    Ensuring that safety analysis needs are met in the future is likely to lead to the development of new codes and the further development of existing codes. It is therefore advantageous to define standards for data interfaces and to develop software interfacing techniques which can readily accommodate changes when they are made. Defining interface standards is beneficial but is necessarily restricted in application if future requirements are not known in detail. Code interfacing methods are of particular relevance with the move towards automatic grid frequency response operation where the integration of plant dynamic, core follow and fault study calculation tools is considered advantageous. This paper describes the background and features of a new code TALINK (Transient Analysis code LINKage program) used to provide a flexible interface to link the RELAP5 thermal hydraulics code with the PANTHER neutron kinetics and the SIBDYM whole plant dynamic modelling codes used by Nuclear Electric. The complete package enables the codes to be executed in parallel and provides an integrated whole plant thermal-hydraulics and neutron kinetics model. In addition the paper discusses the capabilities and pedigree of the component codes used to form the integrated transient analysis package and the details of the calculation of a postulated Sizewell 'B' Loss of offsite power fault transient

  7. Discussion on LDPC Codes and Uplink Coding

    Science.gov (United States)

    Andrews, Ken; Divsalar, Dariush; Dolinar, Sam; Moision, Bruce; Hamkins, Jon; Pollara, Fabrizio

    2007-01-01

    This slide presentation reviews the progress that the workgroup on Low-Density Parity-Check (LDPC) for space link coding. The workgroup is tasked with developing and recommending new error correcting codes for near-Earth, Lunar, and deep space applications. Included in the presentation is a summary of the technical progress of the workgroup. Charts that show the LDPC decoder sensitivity to symbol scaling errors are reviewed, as well as a chart showing the performance of several frame synchronizer algorithms compared to that of some good codes and LDPC decoder tests at ESTL. Also reviewed is a study on Coding, Modulation, and Link Protocol (CMLP), and the recommended codes. A design for the Pseudo-Randomizer with LDPC Decoder and CRC is also reviewed. A chart that summarizes the three proposed coding systems is also presented.

  8. Parallelization characteristics of the DeCART code

    International Nuclear Information System (INIS)

    Cho, J. Y.; Joo, H. G.; Kim, H. Y.; Lee, C. C.; Chang, M. H.; Zee, S. Q.

    2003-12-01

    This report is to describe the parallelization characteristics of the DeCART code and also examine its parallel performance. Parallel computing algorithms are implemented to DeCART to reduce the tremendous computational burden and memory requirement involved in the three-dimensional whole core transport calculation. In the parallelization of the DeCART code, the axial domain decomposition is first realized by using MPI (Message Passing Interface), and then the azimuthal angle domain decomposition by using either MPI or OpenMP. When using the MPI for both the axial and the angle domain decomposition, the concept of MPI grouping is employed for convenient communication in each communication world. For the parallel computation, most of all the computing modules except for the thermal hydraulic module are parallelized. These parallelized computing modules include the MOC ray tracing, CMFD, NEM, region-wise cross section preparation and cell homogenization modules. For the distributed allocation, most of all the MOC and CMFD/NEM variables are allocated only for the assigned planes, which reduces the required memory by a ratio of the number of the assigned planes to the number of all planes. The parallel performance of the DeCART code is evaluated by solving two problems, a rodded variation of the C5G7 MOX three-dimensional benchmark problem and a simplified three-dimensional SMART PWR core problem. In the aspect of parallel performance, the DeCART code shows a good speedup of about 40.1 and 22.4 in the ray tracing module and about 37.3 and 20.2 in the total computing time when using 48 CPUs on the IBM Regatta and 24 CPUs on the LINUX cluster, respectively. In the comparison between the MPI and OpenMP, OpenMP shows a somewhat better performance than MPI. Therefore, it is concluded that the first priority in the parallel computation of the DeCART code is in the axial domain decomposition by using MPI, and then in the angular domain using OpenMP, and finally the angular

  9. Coding visual features extracted from video sequences.

    Science.gov (United States)

    Baroffio, Luca; Cesana, Matteo; Redondi, Alessandro; Tagliasacchi, Marco; Tubaro, Stefano

    2014-05-01

    Visual features are successfully exploited in several applications (e.g., visual search, object recognition and tracking, etc.) due to their ability to efficiently represent image content. Several visual analysis tasks require features to be transmitted over a bandwidth-limited network, thus calling for coding techniques to reduce the required bit budget, while attaining a target level of efficiency. In this paper, we propose, for the first time, a coding architecture designed for local features (e.g., SIFT, SURF) extracted from video sequences. To achieve high coding efficiency, we exploit both spatial and temporal redundancy by means of intraframe and interframe coding modes. In addition, we propose a coding mode decision based on rate-distortion optimization. The proposed coding scheme can be conveniently adopted to implement the analyze-then-compress (ATC) paradigm in the context of visual sensor networks. That is, sets of visual features are extracted from video frames, encoded at remote nodes, and finally transmitted to a central controller that performs visual analysis. This is in contrast to the traditional compress-then-analyze (CTA) paradigm, in which video sequences acquired at a node are compressed and then sent to a central unit for further processing. In this paper, we compare these coding paradigms using metrics that are routinely adopted to evaluate the suitability of visual features in the context of content-based retrieval, object recognition, and tracking. Experimental results demonstrate that, thanks to the significant coding gains achieved by the proposed coding scheme, ATC outperforms CTA with respect to all evaluation metrics.

  10. Pilotless Frame Synchronization Using LDPC Code Constraints

    Science.gov (United States)

    Jones, Christopher; Vissasenor, John

    2009-01-01

    A method of pilotless frame synchronization has been devised for low- density parity-check (LDPC) codes. In pilotless frame synchronization , there are no pilot symbols; instead, the offset is estimated by ex ploiting selected aspects of the structure of the code. The advantag e of pilotless frame synchronization is that the bandwidth of the sig nal is reduced by an amount associated with elimination of the pilot symbols. The disadvantage is an increase in the amount of receiver data processing needed for frame synchronization.

  11. Measurements of electrically exploded tubes

    International Nuclear Information System (INIS)

    Shearer, J.W.; Hartman, C.W.; Munger, R.H.; Gullickson, R.L.; Trimble, D.O.; Cheng, D.Y.

    1975-01-01

    The dynamics of electrically exploded tubes were investigated, principally by means of current measurements and flash x-ray pictures. The pinch effect was observed on the tube motion. Pileup of the imploding tube metal was seen on axis. An approximate analytical model can be roughly fitted to the data, but a more complete fit can be obtained with detailed numerical codes. Application of the results to the planning of future gas-embedded Z-pinch experiments is discussed. (U.S.)

  12. Lightening protection, techniques, applied codes and standards. Vol. 4

    International Nuclear Information System (INIS)

    Mahmoud, M.; Shaaban, H.; Lamey, S.

    1996-01-01

    Lightening is the only natural disaster that protection against is highly effective. Therefore for the safety of critical installations specifically nuclear, an effective lightening protection system (LPS) is required. The design and installation of LPS's have been addressed by many international codes and standards. In this paper, the various LPS's are discussed and compared, including radioactive air terminals, ionizing air terminals, and terminals equipped with electrical trigging devices. Also, the so-called dissipation array systems are discussed and compared to other systems technically and economically. Moreover, the available international codes and standards related to the lightening protection are discussed. such standards include those published by the national fire protection association (NFPA), lightening protection institute (LPI), underwriters laboratories (UL), and british standards Finally, the possibility of developing an egyptian national standards is discussed

  13. Increasing the maximally random jammed density with electric field to reduce the fat level in chocolate

    Science.gov (United States)

    Tao, R.; Tang, H.

    Chocolate is one of the most popular food types and flavors in the world. Unfortunately, at present, chocolate products contain too much fat, leading to obesity. For example, a typical molding chocolate has various fat up to 40% in total and chocolate for covering ice cream has fat 50 -60%. Especially, as children are the leading chocolate consumers, reducing the fat level in chocolate products to make them healthier is important and urgent. While this issue was called into attention and elaborated in articles and books decades ago and led to some patent applications, no actual solution was found unfortunately. Why is reducing fat in chocolate so difficult? What is the underlying physical mechanism? We have found that this issue is deeply related to the basic science of soft matters, especially to their viscosity and maximally random jammed (MRJ) density φx. All chocolate productions are handling liquid chocolate, a suspension with cocoa solid particles in melted fat, mainly cocoa butter. The fat level cannot be lower than 1-φxin order to have liquid chocolate to flow. Here we show that that with application of an electric field to liquid chocolate, we can aggregate the suspended particles into prolate spheroids. This microstructure change reduces liquid chocolate's viscosity along the flow direction and increases its MRJ density significantly. Hence the fat level in chocolate can be effectively reduced. We are looking forward to a new class of healthier and tasteful chocolate coming to the market soon. Dept. of Physics, Temple Univ, Philadelphia, PA 19122.

  14. Hybrid Video Coding Based on Bidimensional Matching Pursuit

    Directory of Open Access Journals (Sweden)

    Lorenzo Granai

    2004-12-01

    Full Text Available Hybrid video coding combines together two stages: first, motion estimation and compensation predict each frame from the neighboring frames, then the prediction error is coded, reducing the correlation in the spatial domain. In this work, we focus on the latter stage, presenting a scheme that profits from some of the features introduced by the standard H.264/AVC for motion estimation and replaces the transform in the spatial domain. The prediction error is so coded using the matching pursuit algorithm which decomposes the signal over an appositely designed bidimensional, anisotropic, redundant dictionary. Comparisons are made among the proposed technique, H.264, and a DCT-based coding scheme. Moreover, we introduce fast techniques for atom selection, which exploit the spatial localization of the atoms. An adaptive coding scheme aimed at optimizing the resource allocation is also presented, together with a rate-distortion study for the matching pursuit algorithm. Results show that the proposed scheme outperforms the standard DCT, especially at very low bit rates.

  15. Multi-stage decoding for multi-level block modulation codes

    Science.gov (United States)

    Lin, Shu

    1991-01-01

    In this paper, we investigate various types of multi-stage decoding for multi-level block modulation codes, in which the decoding of a component code at each stage can be either soft-decision or hard-decision, maximum likelihood or bounded-distance. Error performance of codes is analyzed for a memoryless additive channel based on various types of multi-stage decoding, and upper bounds on the probability of an incorrect decoding are derived. Based on our study and computation results, we find that, if component codes of a multi-level modulation code and types of decoding at various stages are chosen properly, high spectral efficiency and large coding gain can be achieved with reduced decoding complexity. In particular, we find that the difference in performance between the suboptimum multi-stage soft-decision maximum likelihood decoding of a modulation code and the single-stage optimum decoding of the overall code is very small: only a fraction of dB loss in SNR at the probability of an incorrect decoding for a block of 10(exp -6). Multi-stage decoding of multi-level modulation codes really offers a way to achieve the best of three worlds, bandwidth efficiency, coding gain, and decoding complexity.

  16. Measurements and simulations for peak electrical load reduction in cooling dominated climate

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Boehm, Robert F.

    2012-01-01

    Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home. -- Highlights: ► A study to demonstrate peak load reductions of 65% at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 37% through energy efficiency. ► A 1.8 kWp system along with energy efficiency measures decreased peak by 46%.

  17. Operating characteristics and modeling of the LLNL 100-kV electric gun

    International Nuclear Information System (INIS)

    Osher, J.E.; Barnes, G.; Chau, H.H.; Lee, R.S.; Lee, C.; Speer, R.; Weingart, R.C.

    1989-01-01

    In the electric gun, the explosion of an electrically heated metal foil and the accompanying magnetic forces drive a thin flyer plate up a short barrel. Flyer velocities of up to 18 km/s make the gun useful for hypervelocity impact studies. The authors briefly review the technological evolution of the exploding-metal circuit elements that power the gun, describe the 100-kV electric gun designed at Lawrence Livermore National Laboratory (LLNL) in some detail, and present the general principles of electric gun operation. They compare the experimental performance of the LLNL gun with a simple model and with predictions of a magnetohydrodynamics code

  18. Pulsed and streamer discharges in air above breakdown electric field

    NARCIS (Netherlands)

    A.B. Sun (Anbang); H.J. Teunissen (Jannis); U. M. Ebert (Ute)

    2013-01-01

    htmlabstractA 3D particle model is developed to investigate the streamer formation in electric fields above the breakdown threshold, in atmospheric air (1bar, 300 Kelvin). Adaptive particle management, adaptive mesh refinement and parallel computing techniques are used in the code. Photoionization

  19. Utilizing Physiological Principles of Motor Unit Recruitment to Reduce Fatigability of Electrically-Evoked Contractions: A Narrative Review.

    Science.gov (United States)

    Barss, Trevor S; Ainsley, Emily N; Claveria-Gonzalez, Francisca C; Luu, M John; Miller, Dylan J; Wiest, Matheus J; Collins, David F

    2018-04-01

    Neuromuscular electrical stimulation (NMES) is used to produce contractions to restore movement and reduce secondary complications for individuals experiencing motor impairment. NMES is conventionally delivered through a single pair of electrodes over a muscle belly or nerve trunk using short pulse durations and frequencies between 20 and 40Hz (conventional NMES). Unfortunately, the benefits and widespread use of conventional NMES are limited by contraction fatigability, which is in large part because of the nonphysiological way that contractions are generated. This review provides a summary of approaches designed to reduce fatigability during NMES, by using physiological principles that help minimize fatigability of voluntary contractions. First, relevant principles of the recruitment and discharge of motor units (MUs) inherent to voluntary contractions and conventional NMES are introduced, and the main mechanisms of fatigability for each contraction type are briefly discussed. A variety of NMES approaches are then described that were designed to reduce fatigability by generating contractions that more closely mimic voluntary contractions. These approaches include altering stimulation parameters, to recruit MUs in their physiological order, and stimulating through multiple electrodes, to reduce MU discharge rates. Although each approach has unique advantages and disadvantages, approaches that minimize MU discharge rates hold the most promise for imminent translation into rehabilitation practice. The way that NMES is currently delivered limits its utility as a rehabilitative tool. Reducing fatigability by delivering NMES in ways that better mimic voluntary contractions holds promise for optimizing the benefits and widespread use of NMES-based programs. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. A Semantic Analysis Method for Scientific and Engineering Code

    Science.gov (United States)

    Stewart, Mark E. M.

    1998-01-01

    This paper develops a procedure to statically analyze aspects of the meaning or semantics of scientific and engineering code. The analysis involves adding semantic declarations to a user's code and parsing this semantic knowledge with the original code using multiple expert parsers. These semantic parsers are designed to recognize formulae in different disciplines including physical and mathematical formulae and geometrical position in a numerical scheme. In practice, a user would submit code with semantic declarations of primitive variables to the analysis procedure, and its semantic parsers would automatically recognize and document some static, semantic concepts and locate some program semantic errors. A prototype implementation of this analysis procedure is demonstrated. Further, the relationship between the fundamental algebraic manipulations of equations and the parsing of expressions is explained. This ability to locate some semantic errors and document semantic concepts in scientific and engineering code should reduce the time, risk, and effort of developing and using these codes.

  1. Improved diffusion coefficients generated from Monte Carlo codes

    International Nuclear Information System (INIS)

    Herman, B. R.; Forget, B.; Smith, K.; Aviles, B. N.

    2013-01-01

    Monte Carlo codes are becoming more widely used for reactor analysis. Some of these applications involve the generation of diffusion theory parameters including macroscopic cross sections and diffusion coefficients. Two approximations used to generate diffusion coefficients are assessed using the Monte Carlo code MC21. The first is the method of homogenization; whether to weight either fine-group transport cross sections or fine-group diffusion coefficients when collapsing to few-group diffusion coefficients. The second is a fundamental approximation made to the energy-dependent P1 equations to derive the energy-dependent diffusion equations. Standard Monte Carlo codes usually generate a flux-weighted transport cross section with no correction to the diffusion approximation. Results indicate that this causes noticeable tilting in reconstructed pin powers in simple test lattices with L2 norm error of 3.6%. This error is reduced significantly to 0.27% when weighting fine-group diffusion coefficients by the flux and applying a correction to the diffusion approximation. Noticeable tilting in reconstructed fluxes and pin powers was reduced when applying these corrections. (authors)

  2. New quantum codes constructed from quaternary BCH codes

    Science.gov (United States)

    Xu, Gen; Li, Ruihu; Guo, Luobin; Ma, Yuena

    2016-10-01

    In this paper, we firstly study construction of new quantum error-correcting codes (QECCs) from three classes of quaternary imprimitive BCH codes. As a result, the improved maximal designed distance of these narrow-sense imprimitive Hermitian dual-containing quaternary BCH codes are determined to be much larger than the result given according to Aly et al. (IEEE Trans Inf Theory 53:1183-1188, 2007) for each different code length. Thus, families of new QECCs are newly obtained, and the constructed QECCs have larger distance than those in the previous literature. Secondly, we apply a combinatorial construction to the imprimitive BCH codes with their corresponding primitive counterpart and construct many new linear quantum codes with good parameters, some of which have parameters exceeding the finite Gilbert-Varshamov bound for linear quantum codes.

  3. Application and analysis of performance of dqpsk advanced modulation format in spectral amplitude coding ocdma

    International Nuclear Information System (INIS)

    Memon, A.

    2015-01-01

    SAC (Spectral Amplitude Coding) is a technique of OCDMA (Optical Code Division Multiple Access) to encode and decode data bits by utilizing spectral components of the broadband source. Usually OOK (ON-Off-Keying) modulation format is used in this encoding scheme. To make SAC OCDMA network spectrally efficient, advanced modulation format of DQPSK (Differential Quaternary Phase Shift Keying) is applied, simulated and analyzed, m-sequence code is encoded in the simulated setup. Performance regarding various lengths of m-sequence code is also analyzed and displayed in the pictorial form. The results of the simulation are evaluated with the help of electrical constellation diagram, eye diagram and bit error rate graph. All the graphs indicate better transmission quality in case of advanced modulation format of DQPSK used in SAC OCDMA network as compared with OOK. (author)

  4. Hybrid electric vehicles energy management strategies

    CERN Document Server

    Onori, Simona; Rizzoni, Giorgio

    2016-01-01

    This SpringerBrief deals with the control and optimization problem in hybrid electric vehicles. Given that there are two (or more) energy sources (i.e., battery and fuel) in hybrid vehicles, it shows the reader how to implement an energy-management strategy that decides how much of the vehicle’s power is provided by each source instant by instant. Hybrid Electric Vehicles: •introduces methods for modeling energy flow in hybrid electric vehicles; •presents a standard mathematical formulation of the optimal control problem; •discusses different optimization and control strategies for energy management, integrating the most recent research results; and •carries out an overall comparison of the different control strategies presented. Chapter by chapter, a case study is thoroughly developed, providing illustrative numerical examples that show the basic principles applied to real-world situations. In addition to the examples, simulation code is provided via a website, so that readers can work on the actua...

  5. The FORTRAN NALAP code adapted to a microcomputer compiler

    International Nuclear Information System (INIS)

    Lobo, Paulo David de Castro; Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso

    2010-01-01

    The Nuclear Energy Division of the Institute for Advanced Studies (IEAv) is conducting the TERRA project (TEcnologia de Reatores Rapidos Avancados), Technology for Advanced Fast Reactors project, aimed at a space reactor application. In this work, to attend the TERRA project, the NALAP code adapted to a microcomputer compiler called Compaq Visual Fortran (Version 6.6) is presented. This code, adapted from the light water reactor transient code RELAP 3B, simulates thermal-hydraulic responses for sodium cooled fast reactors. The strategy to run the code in a PC was divided in some steps mainly to remove unnecessary routines, to eliminate old statements, to introduce new ones and also to include extension precision mode. The source program was able to solve three sample cases under conditions of protected transients suggested in literature: the normal reactor shutdown, with a delay of 200 ms to start the control rod movement and a delay of 500 ms to stop the pumps; reactor scram after transient of loss of flow; and transients protected from overpower. Comparisons were made with results from the time when the NALAP code was acquired by the IEAv, back in the 80's. All the responses for these three simulations reproduced the calculations performed with the CDC compiler in 1985. Further modifications will include the usage of gas as coolant for the nuclear reactor to allow a Closed Brayton Cycle Loop - CBCL - to be used as a heat/electric converter. (author)

  6. The FORTRAN NALAP code adapted to a microcomputer compiler

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Paulo David de Castro; Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso, E-mail: plobo.a@uol.com.b, E-mail: eduardo@ieav.cta.b, E-mail: fbraz@ieav.cta.b, E-mail: guimarae@ieav.cta.b [Instituto de Estudos Avancados (IEAv/CTA), Sao Jose dos Campos, SP (Brazil)

    2010-07-01

    The Nuclear Energy Division of the Institute for Advanced Studies (IEAv) is conducting the TERRA project (TEcnologia de Reatores Rapidos Avancados), Technology for Advanced Fast Reactors project, aimed at a space reactor application. In this work, to attend the TERRA project, the NALAP code adapted to a microcomputer compiler called Compaq Visual Fortran (Version 6.6) is presented. This code, adapted from the light water reactor transient code RELAP 3B, simulates thermal-hydraulic responses for sodium cooled fast reactors. The strategy to run the code in a PC was divided in some steps mainly to remove unnecessary routines, to eliminate old statements, to introduce new ones and also to include extension precision mode. The source program was able to solve three sample cases under conditions of protected transients suggested in literature: the normal reactor shutdown, with a delay of 200 ms to start the control rod movement and a delay of 500 ms to stop the pumps; reactor scram after transient of loss of flow; and transients protected from overpower. Comparisons were made with results from the time when the NALAP code was acquired by the IEAv, back in the 80's. All the responses for these three simulations reproduced the calculations performed with the CDC compiler in 1985. Further modifications will include the usage of gas as coolant for the nuclear reactor to allow a Closed Brayton Cycle Loop - CBCL - to be used as a heat/electric converter. (author)

  7. Recent development of non-oriented electrical steel sheet for automobile electrical devices

    International Nuclear Information System (INIS)

    Oda, Yoshihiko; Kohno, Masaaki; Honda, Atsuhito

    2008-01-01

    This paper describes non-oriented electrical steel sheet for automobile motors and reactors. Electrical steel sheets for energy efficient motors show high magnetic flux density and low iron loss. They are suitable for HEV traction motors and EPS motors. A thin-gauge electrical steel sheet and a gradient Si steel sheet show low iron loss in the high-frequency range. Therefore, the efficiency of high-frequency devices can be greatly improved. Since a 6.5% Si steel sheet possesses low iron loss and zero magnetostriction, it contributes to reduce the core loss and audible noise of high-frequency reactors

  8. Possibilities for Automatic Control of Hydro-Mechanical Transmission and Birotating Electric Machine

    Directory of Open Access Journals (Sweden)

    V. V. Mikhailov

    2014-01-01

    Full Text Available The paper presents mathematical models and results of virtual investigations pertaining to the selected motion parameters of a mobile machine equipped with hydro mechanical and modernized transmissions. The machine has been tested in similar technological cycles and it has been equipped with a universal automatic control system. Changes in structure and type of power transmission have been obtained with the help of a control algorithm including an extra reversible electric machine which is switched in at some operational modes.Implementation of the proposed  concept makes it possible to obtain and check the improved C-code of the control system and enhance operational parameters of the transmission and machine efficiency, reduce slippage and tire wear while using braking energy for its later beneficial use which is usually considered as a consumable element.

  9. Entanglement-assisted quantum MDS codes from negacyclic codes

    Science.gov (United States)

    Lu, Liangdong; Li, Ruihu; Guo, Luobin; Ma, Yuena; Liu, Yang

    2018-03-01

    The entanglement-assisted formalism generalizes the standard stabilizer formalism, which can transform arbitrary classical linear codes into entanglement-assisted quantum error-correcting codes (EAQECCs) by using pre-shared entanglement between the sender and the receiver. In this work, we construct six classes of q-ary entanglement-assisted quantum MDS (EAQMDS) codes based on classical negacyclic MDS codes by exploiting two or more pre-shared maximally entangled states. We show that two of these six classes q-ary EAQMDS have minimum distance more larger than q+1. Most of these q-ary EAQMDS codes are new in the sense that their parameters are not covered by the codes available in the literature.

  10. Visualizing code and coverage changes for code review

    NARCIS (Netherlands)

    Oosterwaal, Sebastiaan; van Deursen, A.; De Souza Coelho, R.; Sawant, A.A.; Bacchelli, A.

    2016-01-01

    One of the tasks of reviewers is to verify that code modifications are well tested. However, current tools offer little support in understanding precisely how changes to the code relate to changes to the tests. In particular, it is hard to see whether (modified) test code covers the changed code.

  11. Homological stabilizer codes

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Jonas T., E-mail: jonastyleranderson@gmail.com

    2013-03-15

    In this paper we define homological stabilizer codes on qubits which encompass codes such as Kitaev's toric code and the topological color codes. These codes are defined solely by the graphs they reside on. This feature allows us to use properties of topological graph theory to determine the graphs which are suitable as homological stabilizer codes. We then show that all toric codes are equivalent to homological stabilizer codes on 4-valent graphs. We show that the topological color codes and toric codes correspond to two distinct classes of graphs. We define the notion of label set equivalencies and show that under a small set of constraints the only homological stabilizer codes without local logical operators are equivalent to Kitaev's toric code or to the topological color codes. - Highlights: Black-Right-Pointing-Pointer We show that Kitaev's toric codes are equivalent to homological stabilizer codes on 4-valent graphs. Black-Right-Pointing-Pointer We show that toric codes and color codes correspond to homological stabilizer codes on distinct graphs. Black-Right-Pointing-Pointer We find and classify all 2D homological stabilizer codes. Black-Right-Pointing-Pointer We find optimal codes among the homological stabilizer codes.

  12. Coding Transparency in Object-Based Video

    DEFF Research Database (Denmark)

    Aghito, Shankar Manuel; Forchhammer, Søren

    2006-01-01

    A novel algorithm for coding gray level alpha planes in object-based video is presented. The scheme is based on segmentation in multiple layers. Different coders are specifically designed for each layer. In order to reduce the bit rate, cross-layer redundancies as well as temporal correlation are...

  13. A Spanish version for the new ERA-EDTA coding system for primary renal disease

    Directory of Open Access Journals (Sweden)

    Óscar Zurriaga

    2015-07-01

    Conclusions: Translation and adaptation into Spanish represent an improvement that will help to introduce and use the new coding system for PKD, as it can help reducing the time devoted to coding and also the period of adaptation of health workers to the new codes.

  14. Using Economic Incentives to Reduce Electricity Consumption: A field Experiment in Matsuyama, Japan

    OpenAIRE

    Kenichi Mizobuchi; Kenji Takeuchi

    2012-01-01

    This study examines the effectiveness of economic incentives in promoting electricity-conservation behavior among Japanese households. Fifty-three Japanese households participated in a field experiment and were offered monetary rewards depending on their rate of reduction in electricity consumption. To avoid bias in sample selection, which is typically present in previous studies, we adopted a request-based approach for recruiting participants. Results showed that only 34% of the participants...

  15. Two-phase computer codes for zero-gravity applications

    International Nuclear Information System (INIS)

    Krotiuk, W.J.

    1986-10-01

    This paper discusses the problems existing in the development of computer codes which can analyze the thermal-hydraulic behavior of two-phase fluids especially in low gravity nuclear reactors. The important phenomenon affecting fluid flow and heat transfer in reduced gravity is discussed. The applicability of using existing computer codes for space applications is assessed. Recommendations regarding the use of existing earth based fluid flow and heat transfer correlations are made and deficiencies in these correlations are identified

  16. SPECTRAL AMPLITUDE CODING OCDMA SYSTEMS USING ENHANCED DOUBLE WEIGHT CODE

    Directory of Open Access Journals (Sweden)

    F.N. HASOON

    2006-12-01

    Full Text Available A new code structure for spectral amplitude coding optical code division multiple access systems based on double weight (DW code families is proposed. The DW has a fixed weight of two. Enhanced double-weight (EDW code is another variation of a DW code family that can has a variable weight greater than one. The EDW code possesses ideal cross-correlation properties and exists for every natural number n. A much better performance can be provided by using the EDW code compared to the existing code such as Hadamard and Modified Frequency-Hopping (MFH codes. It has been observed that theoretical analysis and simulation for EDW is much better performance compared to Hadamard and Modified Frequency-Hopping (MFH codes.

  17. State Waste Discharge Permit Application: Electric resistance tomography testing

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This permit application documentation is for a State Waste Discharge Permit issued in accordance with requirements of Washington Administrative Code 173-216. The activity being permitted is a technology test using electrical resistance tomography. The electrical resistance tomography technology was developed at Lawrence Livermore National Laboratory and has been used at other waste sites to track underground contamination plumes. The electrical resistance tomography technology measures soil electrical resistance between two electrodes. If a fluid contaminated with electrolytes is introduced into the soil, the soil resistance is expected to drop. By using an array of measurement electrodes in several boreholes, the areal extent of contamination can be estimated. At the Hanford Site, the purpose of the testing is to determine if the electrical resistance tomography technology can be used in the vicinity of large underground metal tanks without the metal tank interfering with the test. It is anticipated that the electrical resistance tomography technology will provide a method for accurately detecting leaks from the bottom of underground tanks, such as the Hanford Site single-shell tanks.

  18. Spiking patterns of a hippocampus model in electric fields

    International Nuclear Information System (INIS)

    Men Cong; Wang Jiang; Qin Ying-Mei; Wei Xi-Le; Deng Bin; Che Yan-Qiu

    2011-01-01

    We develop a model of CA3 neurons embedded in a resistive array to mimic the effects of electric fields from a new perspective. Effects of DC and sinusoidal electric fields on firing patterns in CA3 neurons are investigated in this study. The firing patterns can be switched from no firing pattern to burst or from burst to fast periodic firing pattern with the increase of DC electric field intensity. It is also found that the firing activities are sensitive to the frequency and amplitude of the sinusoidal electric field. Different phase-locking states and chaotic firing regions are observed in the parameter space of frequency and amplitude. These findings are qualitatively in accordance with the results of relevant experimental and numerical studies. It is implied that the external or endogenous electric field can modulate the neural code in the brain. Furthermore, it is helpful to develop control strategies based on electric fields to control neural diseases such as epilepsy. (interdisciplinary physics and related areas of science and technology)

  19. State Waste Discharge Permit Application: Electric resistance tomography testing

    International Nuclear Information System (INIS)

    1994-04-01

    This permit application documentation is for a State Waste Discharge Permit issued in accordance with requirements of Washington Administrative Code 173-216. The activity being permitted is a technology test using electrical resistance tomography. The electrical resistance tomography technology was developed at Lawrence Livermore National Laboratory and has been used at other waste sites to track underground contamination plumes. The electrical resistance tomography technology measures soil electrical resistance between two electrodes. If a fluid contaminated with electrolytes is introduced into the soil, the soil resistance is expected to drop. By using an array of measurement electrodes in several boreholes, the areal extent of contamination can be estimated. At the Hanford Site, the purpose of the testing is to determine if the electrical resistance tomography technology can be used in the vicinity of large underground metal tanks without the metal tank interfering with the test. It is anticipated that the electrical resistance tomography technology will provide a method for accurately detecting leaks from the bottom of underground tanks, such as the Hanford Site single-shell tanks

  20. Novel Area Optimization in FPGA Implementation Using Efficient VHDL Code

    Directory of Open Access Journals (Sweden)

    . Zulfikar

    2012-10-01

    Full Text Available A new novel method for area efficiency in FPGA implementation is presented. The method is realized through flexibility and wide capability of VHDL coding. This method exposes the arithmetic operations such as addition, subtraction and others. The design technique aim to reduce occupies area for multi stages circuits by selecting suitable range of all value involved in every step of calculations. Conventional and efficient VHDL coding methods are presented and the synthesis result is compared. The VHDL code which limits range of integer values is occupies less area than the one which is not. This VHDL coding method is suitable for multi stage circuits.

  1. Novel Area Optimization in FPGA Implementation Using Efficient VHDL Code

    Directory of Open Access Journals (Sweden)

    Zulfikar .

    2015-05-01

    Full Text Available A new novel method for area efficiency in FPGA implementation is presented. The method is realized through flexibility and wide capability of VHDL coding. This method exposes the arithmetic operations such as addition, subtraction and others. The design technique aim to reduce occupies area for multi stages circuits by selecting suitable range of all value involved in every step of calculations. Conventional and efficient VHDL coding methods are presented and the synthesis result is compared. The VHDL code which limits range of integer values is occupies less area than the one which is not. This VHDL coding method is suitable for multi stage circuits.

  2. Numerical code to determine the particle trapping region in the LISA machine

    International Nuclear Information System (INIS)

    Azevedo, M.T. de; Raposo, C.C. de; Tomimura, A.

    1984-01-01

    A numerical code is constructed to determine the trapping region in machine like LISA. The variable magnetic field is two deimensional and is coupled to the Runge-Kutta through the Tchebichev polynomial. Various particle orbits including particle interactions were analysed. Beside this, a strong electric field is introduced to see the possible effects happening inside the plasma. (Author) [pt

  3. Channel coding for underwater acoustic single-carrier CDMA communication system

    Science.gov (United States)

    Liu, Lanjun; Zhang, Yonglei; Zhang, Pengcheng; Zhou, Lin; Niu, Jiong

    2017-01-01

    CDMA is an effective multiple access protocol for underwater acoustic networks, and channel coding can effectively reduce the bit error rate (BER) of the underwater acoustic communication system. For the requirements of underwater acoustic mobile networks based on CDMA, an underwater acoustic single-carrier CDMA communication system (UWA/SCCDMA) based on the direct-sequence spread spectrum is proposed, and its channel coding scheme is studied based on convolution, RA, Turbo and LDPC coding respectively. The implementation steps of the Viterbi algorithm of convolutional coding, BP and minimum sum algorithms of RA coding, Log-MAP and SOVA algorithms of Turbo coding, and sum-product algorithm of LDPC coding are given. An UWA/SCCDMA simulation system based on Matlab is designed. Simulation results show that the UWA/SCCDMA based on RA, Turbo and LDPC coding have good performance such that the communication BER is all less than 10-6 in the underwater acoustic channel with low signal to noise ratio (SNR) from -12 dB to -10dB, which is about 2 orders of magnitude lower than that of the convolutional coding. The system based on Turbo coding with Log-MAP algorithm has the best performance.

  4. The potential of electric vehicles

    International Nuclear Information System (INIS)

    2016-04-01

    Electric vehicles can help reduce the dependence of road transport on imported oil, cut the country's energy bill, reduce greenhouse gas emissions, improve air quality in cities through zero exhaust emissions and reduce noise pollution. The economic costs and environmental impacts of electric vehicles are mostly concentrated at the manufacturing stage, whereas the costs and impacts of internal combustion vehicles are predominantly felt during usage. So we cannot simply compare vehicles as objects, we must see how they are used, which means taking a fresh look at the full potential of electric vehicles which must be used intensely to be economically and environmentally viable. The main advantage of internal combustion vehicles is their ability to carry a very large amount of energy giving them a very large range and significant versatility. However, the consequences of the use of fossil fuels on the climate and the environment today require us to look for other solutions for vehicles and mobility systems. Electric vehicles are among these: its lack of versatility, due to its still limited range, is offset by being more adaptable and optimised for the usage sought. Electric vehicles are particularly suitable for new mobility services offerings and allow the transition to new ways of travelling to be speeded up optimising the use of the vehicle and no longer requiring ownership of it. The use of digital, facilitated by the electrical engine, opens up numerous opportunities for innovations and new services (such as the autonomous vehicle for example). In addition, electric vehicles can do more than just transport. Their batteries provide useful energy storage capabilities that can help regulate the power grid and the development of renewable energy. The marketing of electric vehicles may be accompanied by energy services that can be economically viable and used to structure the electro-mobility offer in return. To minimise the impact on the electrical grid, it is

  5. Canadian consumer issues in accurate and fair electricity metering

    International Nuclear Information System (INIS)

    2000-07-01

    The Public Interest Advocacy Centre (PIAC), located in Ottawa, participates in regulatory proceedings concerning electricity and natural gas to support public and consumer interest. PIAC provides legal representation, research and policy support and public advocacy. A study aimed toward the determination of the issues at stake for residential electricity consumers in the provision of fair and accurate electricity metering, was commissioned by Measurement Canada in consultation with Industry Canada's Consumer Affairs. The metering of electricity must be carried out in a fair and efficient manner for all residential consumers. The Electricity, Gas and Inspection Act was developed to ensure compliance with standards for measuring instrumentation. The accurate metering of electricity through the distribution systems for electricity in Canada represents the main focus of this study and report. The role played by Measurement Canada and the increased efficiencies of service delivery by Measurement Canada or the changing of electricity market conditions are of special interest. The role of Measurement Canada was explained, as were the concerns of residential consumers. A comparison was then made between the interests of residential consumers and those of commercial and industrial electricity consumers in electricity metering. Selected American and Commonwealth jurisdictions were reviewed in light of their electricity metering practices. A section on compliance and conflict resolution was included, in addition to a section on the use of voluntary codes for compliance and conflict resolution

  6. The plant for co-production of synfuel and electricity with reduced CO{sub 2} emissions

    Energy Technology Data Exchange (ETDEWEB)

    Kler, A.M.; Tyurina, E.A.; Mednikov, A.S. [Russian Academy of Sciences, Irkutsk (Russian Federation). Energy Systems Inst.

    2013-07-01

    Consideration is given to the prospective technologies for combined production of synthetic fuel (SF) and electricity. The mathematical models of plant for co-production of synfuel and electricity (PCSE) intended for combined production of electricity and synthesis of methanol and dimethyl ether or membrane-based hydrogen production from coal were developed. They were used in the optimization studies on the installations. As a result of the studies, the design characteristics for the plant elements, the relationships between the SF and electricity productions, etc. were determined. These data were used to identify the ranges of SF price for various prices of fuel, electricity and equipment, and estimate the profitability of SF production. Special attention is paid to modeling of CO{sub 2} removal system as part of PCSE and studies on PCSE optimization. The account is taken of additional capital investments and power consumption in the systems.

  7. A unified form of exact-MSR codes via product-matrix frameworks

    KAUST Repository

    Lin, Sian Jheng

    2015-02-01

    Regenerating codes represent a class of block codes applicable for distributed storage systems. The [n, k, d] regenerating code has data recovery capability while possessing arbitrary k out of n code fragments, and supports the capability for code fragment regeneration through the use of other arbitrary d fragments, for k ≤ d ≤ n - 1. Minimum storage regenerating (MSR) codes are a subset of regenerating codes containing the minimal size of each code fragment. The first explicit construction of MSR codes that can perform exact regeneration (named exact-MSR codes) for d ≥ 2k - 2 has been presented via a product-matrix framework. This paper addresses some of the practical issues on the construction of exact-MSR codes. The major contributions of this paper include as follows. A new product-matrix framework is proposed to directly include all feasible exact-MSR codes for d ≥ 2k - 2. The mechanism for a systematic version of exact-MSR code is proposed to minimize the computational complexities for the process of message-symbol remapping. Two practical forms of encoding matrices are presented to reduce the size of the finite field.

  8. A unified form of exact-MSR codes via product-matrix frameworks

    KAUST Repository

    Lin, Sian Jheng; Chung, Weiho; Han, Yunghsiangsam; Al-Naffouri, Tareq Y.

    2015-01-01

    Regenerating codes represent a class of block codes applicable for distributed storage systems. The [n, k, d] regenerating code has data recovery capability while possessing arbitrary k out of n code fragments, and supports the capability for code fragment regeneration through the use of other arbitrary d fragments, for k ≤ d ≤ n - 1. Minimum storage regenerating (MSR) codes are a subset of regenerating codes containing the minimal size of each code fragment. The first explicit construction of MSR codes that can perform exact regeneration (named exact-MSR codes) for d ≥ 2k - 2 has been presented via a product-matrix framework. This paper addresses some of the practical issues on the construction of exact-MSR codes. The major contributions of this paper include as follows. A new product-matrix framework is proposed to directly include all feasible exact-MSR codes for d ≥ 2k - 2. The mechanism for a systematic version of exact-MSR code is proposed to minimize the computational complexities for the process of message-symbol remapping. Two practical forms of encoding matrices are presented to reduce the size of the finite field.

  9. Particle tracing code for multispecies gas

    International Nuclear Information System (INIS)

    Eaton, R.R.; Fox, R.L.; Vandevender, W.H.

    1979-06-01

    Details are presented for the development of a computer code designed to calculate the flow of a multispecies gas mixture using particle tracing techniques. The current technique eliminates the need for a full simulation by utilizing local time averaged velocity distribution functions to obtain the dynamic properties for probable collision partners. The development of this concept reduces statistical scatter experienced in conventional Monte Carlo simulations. The technique is applicable to flow problems involving gas mixtures with disparate masses and trace constituents in the Knudsen number, Kn, range from 1.0 to less than 0.01. The resulting code has previously been used to analyze several aerodynamic isotope enrichment devices

  10. 76 FR 22381 - National Fire Codes: Request for Comments on NFPA Technical Committee Reports

    Science.gov (United States)

    2011-04-21

    ... Stored Electrical P Energy Emergency and Standby Power Systems. NFPA 291 Recommended Practice for Fire P.... NFPA 400 Hazardous Materials Code....... P NFPA 402 Guide for Aircraft Rescue and P Fire-Fighting... Installation, P Maintenance, and Use of Emergency Services Communications Systems. NFPA 1500 Standard on Fire...

  11. 78 FR 69286 - Electric System Construction Policies and Procedures

    Science.gov (United States)

    2013-11-19

    ... DEPARTMENT OF AGRICULTURE Rural Utilities Service 7 CFR Part 1726 Electric System Construction Policies and Procedures CFR Correction In Title 7 of the Code of Federal Regulations, Parts 1600 to 1759, revised as of January 1, 2013, on page 246, in Sec. 1726.14, the second definition of Minor modification...

  12. 3D equilibrium codes for mirror machines

    International Nuclear Information System (INIS)

    Kaiser, T.B.

    1983-01-01

    The codes developed for cumputing three-dimensional guiding center equilibria for quadrupole tandem mirrors are discussed. TEBASCO (Tandem equilibrium and ballooning stability code) is a code developed at LLNL that uses a further expansion of the paraxial equilibrium equation in powers of β (plasma pressure/magnetic pressure). It has been used to guide the design of the TMX-U and MFTF-B experiments at Livermore. Its principal weakness is its perturbative nature, which renders its validity for high-β calculation open to question. In order to compute high-β equilibria, the reduced MHD technique that has been proven useful for determining toroidal equilibria was adapted to the tandem mirror geometry. In this approach, the paraxial expansion of the MHD equations yields a set of coupled nonlinear equations of motion valid for arbitrary β, that are solved as an initial-value problem. Two particular formulations have been implemented in computer codes developed at NYU/Kyoto U and LLNL. They differ primarily in the type of grid, the location of the lateral boundary and the damping techniques employed, and in the method of calculating pressure-balance equilibrium. Discussions on these codes are presented in this paper. (Kato, T.)

  13. The role of rotational mechanisms in electron swarm parameters at low reduced electric field in N2, O2 and H2

    International Nuclear Information System (INIS)

    Ridenti, M A; Amorim, J; Alves, L L; Guerra, V

    2015-01-01

    The homogeneous Boltzmann equation for electrons in N 2 , O 2 and H 2 is solved under the classical two-term approximation, for reduced electric fields in the interval 10   −  4   −10 Td where the electron-neutral encounters are limited to elastic, rotational and vibrational collisions. Rotational excitations/de-excitations are described using the following three different approaches: the discrete inelastic/superelastic collisional operator, written for a number of rotational levels that depends on the molecular gas and the specific rotational cross sections considered; the continuous approximation for rotations; a modified version of the continuous approximation for rotations, including a Chapman–Cowling corrective term proportional to the gas temperature. The expression of the rotational collision operator for this latter approach is deduced here and the results show that it bridges the gap between the discrete and the continuous descriptions at low/intermediate reduced electric fields. The calculations are compared with the measurements for the available swarm parameters to assess the validity of the different approaches and cross sections adopted to describe the rotational mechanisms. (paper)

  14. Simulation and energy analysis of distributed electric heating system

    Science.gov (United States)

    Yu, Bo; Han, Shenchao; Yang, Yanchun; Liu, Mingyuan

    2018-02-01

    Distributed electric heating system assistssolar heating systemby using air-source heat pump. Air-source heat pump as auxiliary heat sourcecan make up the defects of the conventional solar thermal system can provide a 24 - hour high - efficiency work. It has certain practical value and practical significance to reduce emissions and promote building energy efficiency. Using Polysun software the system is simulated and compared with ordinary electric boiler heating system. The simulation results show that upon energy request, 5844.5kW energy is saved and 3135kg carbon - dioxide emissions are reduced and5844.5 kWhfuel and energy consumption is decreased with distributed electric heating system. Theeffect of conserving energy and reducing emissions using distributed electric heating systemis very obvious.

  15. The use of HANDIDET reg-sign non-electric detonator assemblies to reduce blast-induced overpressure at AECL's Underground Research Laboratory

    International Nuclear Information System (INIS)

    Onagi, D.P.; Keith, S.G.; Kuzyk, G.W.

    1996-01-01

    A number of aspects of the Canadian concept for nuclear fuel waste disposal are being assessed by Atomic Energy of Canada Limited (AECL) in a series of experiments at its Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba, Canada. One of the major objectives of the work being carried out at the URL is to develop and evaluate the methods and technology to ensure safe, permanent disposal of Canada's nuclear fuel waste. In 1994, AECL excavated access tunnels and a laboratory room for the Quarried Block Fracture Migration Experiment (QBFME) at the 240 Level of the URL. This facility will be used to study the transport of radionuclides in natural fractures in quarried blocks of granite under in-situ groundwater conditions. The experiment is being carried out under a cooperative agreement with the Japan Atomic Energy Research Institute. The excavation of the QBFME access tunnels and laboratory was carried out using controlled blasting techniques that minimized blast-induced overpressure which could have damaged or interrupted other ongoing experiments in the vicinity. The majority of the blasts used conventional long delay non-electric detonators but a number of blasts were carried out using HANDIDET 250/6000 non-electric long delay detonator assemblies and HTD reg-sign non-electric short delay trunkline detonator assemblies. The tunnel and laboratory excavation was monitored to determine the levels of blast-induced overpressure. This paper describes the blasting and monitoring results of the blasts using HANDIDET non-electric detonator assemblies and the effectiveness of these detonators in reducing blast-induced overpressure

  16. Code-modulated interferometric imaging system using phased arrays

    Science.gov (United States)

    Chauhan, Vikas; Greene, Kevin; Floyd, Brian

    2016-05-01

    Millimeter-wave (mm-wave) imaging provides compelling capabilities for security screening, navigation, and bio- medical applications. Traditional scanned or focal-plane mm-wave imagers are bulky and costly. In contrast, phased-array hardware developed for mass-market wireless communications and automotive radar promise to be extremely low cost. In this work, we present techniques which can allow low-cost phased-array receivers to be reconfigured or re-purposed as interferometric imagers, removing the need for custom hardware and thereby reducing cost. Since traditional phased arrays power combine incoming signals prior to digitization, orthogonal code-modulation is applied to each incoming signal using phase shifters within each front-end and two-bit codes. These code-modulated signals can then be combined and processed coherently through a shared hardware path. Once digitized, visibility functions can be recovered through squaring and code-demultiplexing operations. Pro- vided that codes are selected such that the product of two orthogonal codes is a third unique and orthogonal code, it is possible to demultiplex complex visibility functions directly. As such, the proposed system modulates incoming signals but demodulates desired correlations. In this work, we present the operation of the system, a validation of its operation using behavioral models of a traditional phased array, and a benchmarking of the code-modulated interferometer against traditional interferometer and focal-plane arrays.

  17. Current and anticipated use of thermal-hydraulic codes for BWR transient and accident analyses in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Kenji; Ebata, Shigeo [Toshiba Corp., Yokohama (Japan)

    1997-07-01

    This paper summarizes the current and anticipated use of the thermal-hydraulic and neutronic codes for the BWR transient and accident analyses in Japan. The codes may be categorized into the licensing codes and the best estimate codes for the BWR transient and accident analyses. Most of the licensing codes have been originally developed by General Electric. Some codes have been updated based on the technical knowledge obtained in the thermal hydraulic study in Japan, and according to the BWR design changes. The best estimates codes have been used to support the licensing calculations and to obtain the phenomenological understanding of the thermal hydraulic phenomena during a BWR transient or accident. The best estimate codes can be also applied to a design study for a next generation BWR to which the current licensing model may not be directly applied. In order to rationalize the margin included in the current BWR design and develop a next generation reactor with appropriate design margin, it will be required to improve the accuracy of the thermal-hydraulic and neutronic model. In addition, regarding the current best estimate codes, the improvement in the user interface and the numerics will be needed.

  18. Performance of asynchronous fiber-optic code division multiple access system based on three-dimensional wavelength/time/space codes and its link analysis.

    Science.gov (United States)

    Singh, Jaswinder

    2010-03-10

    A novel family of three-dimensional (3-D) wavelength/time/space codes for asynchronous optical code-division-multiple-access (CDMA) systems with "zero" off-peak autocorrelation and "unity" cross correlation is reported. Antipodal signaling and differential detection is employed in the system. A maximum of [(W x T+1) x W] codes are generated for unity cross correlation, where W and T are the number of wavelengths and time chips used in the code and are prime. The conditions for violation of the cross-correlation constraint are discussed. The expressions for number of generated codes are determined for various code dimensions. It is found that the maximum number of codes are generated for S systems. The codes have a code-set-size to code-size ratio greater than W/S. For instance, with a code size of 2065 (59 x 7 x 5), a total of 12,213 users can be supported, and 130 simultaneous users at a bit-error rate (BER) of 10(-9). An arrayed-waveguide-grating-based reconfigurable encoder/decoder design for 2-D implementation for the 3-D codes is presented so that the need for multiple star couplers and fiber ribbons is eliminated. The hardware requirements of the coders used for various modulation/detection schemes are given. The effect of insertion loss in the coders is shown to be significantly reduced with loss compensation by using an amplifier after encoding. An optical CDMA system for four users is simulated and the results presented show the improvement in performance with the use of loss compensation.

  19. Building codes: An often overlooked determinant of health.

    Science.gov (United States)

    Chauvin, James; Pauls, Jake; Strobl, Linda

    2016-05-01

    Although the vast majority of the world's population spends most of their time in buildings, building codes are not often thought of as 'determinants of health'. The standards that govern the design, construction, and use of buildings affect our health, security, safety, and well-being. This is true for dwellings, schools, and universities, shopping centers, places of recreation, places of worship, health-care facilities, and workplaces. We urge proactive engagement by the global public health community in developing these codes, and in the design and implementation of health protection and health promotion activities intended to reduce the risk of injury, disability, and death, particularly when due to poor building code adoption/adaption, application, and enforcement.

  20. General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K. Volume II

    International Nuclear Information System (INIS)

    1976-01-01

    Documentation for the General Electric Evaluation Model is presented. Computer codes and numerical methods common to the codes are described. It is shown how GE BWR's conform to the Acceptance Criteria of 10CFR50.46

  1. Electric power transmission pricing regulations and efficiency

    International Nuclear Information System (INIS)

    Goldoni, G.

    1999-01-01

    An efficient-price mechanism for electricity transmission is very hard to find, essentially because of the natural monopoly condition of the grid and its peculiar interactions with generation. The use of Optimal Power Flow Models is difficult to implement and could be easily distorted by strategical behaviour of generators. These models, however, could became a valuable efficiency-test for actual transmission charges and codes [it

  2. Experience gained in running the EPRI MMS code with an in-house simulation language

    International Nuclear Information System (INIS)

    Weber, D.S.

    1987-01-01

    The EPRI Modular Modeling System (MMS) code represents a collection of component models and a steam/water properties package. This code has undergone extensive verification and validation testing. Currently, the code requires a commercially available simulation language to run. The Philadelphia Electric Company (PECO) has been modeling power plant systems for over the past sixteen years. As a result, an extensive number of models have been developed. In addition, an extensive amount of experience has been developed and gained using an in-house simulation language. The objective of this study was to explore the possibility of developing an MMS pre-processor which would allow the use of the MMS package with other simulation languages such as the PECO in-house simulation language

  3. Investigating the Simulink Auto-Coding Process

    Science.gov (United States)

    Gualdoni, Matthew J.

    2016-01-01

    Model based program design is the most clear and direct way to develop algorithms and programs for interfacing with hardware. While coding "by hand" results in a more tailored product, the ever-growing size and complexity of modern-day applications can cause the project work load to quickly become unreasonable for one programmer. This has generally been addressed by splitting the product into separate modules to allow multiple developers to work in parallel on the same project, however this introduces new potentials for errors in the process. The fluidity, reliability and robustness of the code relies on the abilities of the programmers to communicate their methods to one another; furthermore, multiple programmers invites multiple potentially differing coding styles into the same product, which can cause a loss of readability or even module incompatibility. Fortunately, Mathworks has implemented an auto-coding feature that allows programmers to design their algorithms through the use of models and diagrams in the graphical programming environment Simulink, allowing the designer to visually determine what the hardware is to do. From here, the auto-coding feature handles converting the project into another programming language. This type of approach allows the designer to clearly see how the software will be directing the hardware without the need to try and interpret large amounts of code. In addition, it speeds up the programming process, minimizing the amount of man-hours spent on a single project, thus reducing the chance of human error as well as project turnover time. One such project that has benefited from the auto-coding procedure is Ramses, a portion of the GNC flight software on-board Orion that has been implemented primarily in Simulink. Currently, however, auto-coding Ramses into C++ requires 5 hours of code generation time. This causes issues if the tool ever needs to be debugged, as this code generation will need to occur with each edit to any part of

  4. An Implementation of Error Minimization Data Transmission in OFDM using Modified Convolutional Code

    Directory of Open Access Journals (Sweden)

    Hendy Briantoro

    2016-04-01

    Full Text Available This paper presents about error minimization in OFDM system. In conventional system, usually using channel coding such as BCH Code or Convolutional Code. But, performance BCH Code or Convolutional Code is not good in implementation of OFDM System. Error bits of OFDM system without channel coding is 5.77%. Then, we used convolutional code with code rate 1/2, it can reduce error bitsonly up to 3.85%. So, we proposed OFDM system with Modified Convolutional Code. In this implementation, we used Software Define Radio (SDR, namely Universal Software Radio Peripheral (USRP NI 2920 as the transmitter and receiver. The result of OFDM system using Modified Convolutional Code with code rate is able recover all character received so can decrease until 0% error bit. Increasing performance of Modified Convolutional Code is about 1 dB in BER of 10-4 from BCH Code and Convolutional Code. So, performance of Modified Convolutional better than BCH Code or Convolutional Code. Keywords: OFDM, BCH Code, Convolutional Code, Modified Convolutional Code, SDR, USRP

  5. Summary of aerosol code-comparison results for LWR aerosol containment tests LA1, LA2, and LA3

    International Nuclear Information System (INIS)

    Wright, A.L.; Wilson, J.H.; Arwood, P.C.

    1987-01-01

    The light-water reactor (LWR) aerosol containment experiments (LACE) are being performed in Richland, Washington, at the Hanford Engineering Development Laboratory under the leadership of an international project board and the Electric Power Research Institute. These tests have two objectives: (1) to investigate, at large scale, the inherent aerosol retention behavior in LWR containments under simulated severe accident conditions, and (2) to provide an experimental data base for validating aerosol behavior and thermal-hydraulic computer codes. Aerosol computer-code comparison activities for the LACE tests are being coordinated at the Oak Ridge National Laboratory. For each of the six experiments, pretest calculations (for code-to-code comparisons) and blind post-test calculations (for code-to-test data comparisons) are being performed. This paper presents a summary of the pretest aerosol-code results for tests LA1, LA2, and LA3

  6. Modeling auditory-nerve responses to electrical stimulation

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Dau, Torsten; Epp, Bastian

    2014-01-01

    μs, which is large enough to affect the temporal coding of sounds and hence, potentially, the communication abilities of the CI listener. In the present study, two recently proposed models of electric stimulation of the AN [1,2] were considered in terms of their efficacy to predict the spike timing...... for anodic and cathodic stimulation of the AN of cat [3]. The models’ responses to the electrical pulses of various shapes [4,5,6] were also analyzed. It was found that, while the models can account for the firing rates in response to various biphasic pulse shapes, they fail to correctly describe the timing......Cochlear implants (CI) directly stimulate the auditory nerve (AN), bypassing the mechano-electrical transduction in the inner ear. Trains of biphasic, charge balanced pulses (anodic and cathodic) are used as stimuli to avoid damage of the tissue. The pulses of either polarity are capable...

  7. DLLExternalCode

    Energy Technology Data Exchange (ETDEWEB)

    2014-05-14

    DLLExternalCode is the a general dynamic-link library (DLL) interface for linking GoldSim (www.goldsim.com) with external codes. The overall concept is to use GoldSim as top level modeling software with interfaces to external codes for specific calculations. The DLLExternalCode DLL that performs the linking function is designed to take a list of code inputs from GoldSim, create an input file for the external application, run the external code, and return a list of outputs, read from files created by the external application, back to GoldSim. Instructions for creating the input file, running the external code, and reading the output are contained in an instructions file that is read and interpreted by the DLL.

  8. High efficiency video coding coding tools and specification

    CERN Document Server

    Wien, Mathias

    2015-01-01

    The video coding standard High Efficiency Video Coding (HEVC) targets at improved compression performance for video resolutions of HD and beyond, providing Ultra HD video at similar compressed bit rates as for HD video encoded with the well-established video coding standard H.264 | AVC. Based on known concepts, new coding structures and improved coding tools have been developed and specified in HEVC. The standard is expected to be taken up easily by established industry as well as new endeavors, answering the needs of todays connected and ever-evolving online world. This book presents the High Efficiency Video Coding standard and explains it in a clear and coherent language. It provides a comprehensive and consistently written description, all of a piece. The book targets at both, newbies to video coding as well as experts in the field. While providing sections with introductory text for the beginner, it suits as a well-arranged reference book for the expert. The book provides a comprehensive reference for th...

  9. Methodology for bus layout for topological quantum error correcting codes

    Energy Technology Data Exchange (ETDEWEB)

    Wosnitzka, Martin; Pedrocchi, Fabio L.; DiVincenzo, David P. [RWTH Aachen University, JARA Institute for Quantum Information, Aachen (Germany)

    2016-12-15

    Most quantum computing architectures can be realized as two-dimensional lattices of qubits that interact with each other. We take transmon qubits and transmission line resonators as promising candidates for qubits and couplers; we use them as basic building elements of a quantum code. We then propose a simple framework to determine the optimal experimental layout to realize quantum codes. We show that this engineering optimization problem can be reduced to the solution of standard binary linear programs. While solving such programs is a NP-hard problem, we propose a way to find scalable optimal architectures that require solving the linear program for a restricted number of qubits and couplers. We apply our methods to two celebrated quantum codes, namely the surface code and the Fibonacci code. (orig.)

  10. Min-Max decoding for non binary LDPC codes

    OpenAIRE

    Savin, Valentin

    2008-01-01

    Iterative decoding of non-binary LDPC codes is currently performed using either the Sum-Product or the Min-Sum algorithms or slightly different versions of them. In this paper, several low-complexity quasi-optimal iterative algorithms are proposed for decoding non-binary codes. The Min-Max algorithm is one of them and it has the benefit of two possible LLR domain implementations: a standard implementation, whose complexity scales as the square of the Galois field's cardinality and a reduced c...

  11. Acceleration of the MCNP branch of the OCTOPUS depletion code system

    Energy Technology Data Exchange (ETDEWEB)

    Pijlgroms, B.J.; Hogenbirk, A.; Oppe, J. [Section Nuclear and Reactor Physics, ECN Nuclear Research, Petten (Netherlands)

    1998-09-01

    OCTOPUS depletion calculations using the 3D Monte Carlo spectrum code MCNP (Monte Carlo Code for Neutron and Photon Transport) require much computing time. In a former implementation, the time required by OCTOPUS to perform multi-zone calculations, increased roughly proportional to the number of burnable zones. By using a different method the situation has improved considerably. In the new implementation described here, the dependence of the computing time on the number of zones has been moved from the MCNP code to a faster postprocessing code. By this, the overall computing time will reduce substantially. 11 refs.

  12. Acceleration of the MCNP branch of the OCTOPUS depletion code system

    International Nuclear Information System (INIS)

    Pijlgroms, B.J.; Hogenbirk, A.; Oppe, J.

    1998-09-01

    OCTOPUS depletion calculations using the 3D Monte Carlo spectrum code MCNP (Monte Carlo Code for Neutron and Photon Transport) require much computing time. In a former implementation, the time required by OCTOPUS to perform multi-zone calculations, increased roughly proportional to the number of burnable zones. By using a different method the situation has improved considerably. In the new implementation described here, the dependence of the computing time on the number of zones has been moved from the MCNP code to a faster postprocessing code. By this, the overall computing time will reduce substantially. 11 refs

  13. Temporal code in the vibrissal system-Part II: Roughness surface discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, F D [Departamento de BioingenierIa, FACET, Universidad Nacional de Tucuman, INSIBIO - CONICET, CC 327, Postal Code CP 4000 (Argentina); AlbarracIn, A L [Catedra de Neurociencias, Facultad de Medicina, Universidad Nacional de Tucuman (Argentina); Felice, C J [Departamento de BioingenierIa, FACET, Universidad Nacional de Tucuman, INSIBIO - CONICET, CC 327, Postal Code CP 4000 (Argentina)

    2007-11-15

    Previous works have purposed hypotheses about the neural code of the tactile system in the rat. One of them is based on the physical characteristics of vibrissae, such as frequency of resonance; another is based on discharge patterns on the trigeminal ganglion. In this work, the purpose is to find a temporal code analyzing the afferent signals of two vibrissal nerves while vibrissae sweep surfaces of different roughness. Two levels of pressure were used between the vibrissa and the contact surface. We analyzed the afferent discharge of DELTA and GAMMA vibrissal nerves. The vibrissae movements were produced using electrical stimulation of the facial nerve. The afferent signals were analyzed using an event detection algorithm based on Continuous Wavelet Transform (CWT). The algorithm was able to detect events of different duration. The inter-event times detected were calculated for each situation and represented in box plot. This work allowed establishing the existence of a temporal code at peripheral level.

  14. Temporal code in the vibrissal system-Part II: Roughness surface discrimination

    International Nuclear Information System (INIS)

    Farfan, F D; AlbarracIn, A L; Felice, C J

    2007-01-01

    Previous works have purposed hypotheses about the neural code of the tactile system in the rat. One of them is based on the physical characteristics of vibrissae, such as frequency of resonance; another is based on discharge patterns on the trigeminal ganglion. In this work, the purpose is to find a temporal code analyzing the afferent signals of two vibrissal nerves while vibrissae sweep surfaces of different roughness. Two levels of pressure were used between the vibrissa and the contact surface. We analyzed the afferent discharge of DELTA and GAMMA vibrissal nerves. The vibrissae movements were produced using electrical stimulation of the facial nerve. The afferent signals were analyzed using an event detection algorithm based on Continuous Wavelet Transform (CWT). The algorithm was able to detect events of different duration. The inter-event times detected were calculated for each situation and represented in box plot. This work allowed establishing the existence of a temporal code at peripheral level

  15. Efficient convolutional sparse coding

    Science.gov (United States)

    Wohlberg, Brendt

    2017-06-20

    Computationally efficient algorithms may be applied for fast dictionary learning solving the convolutional sparse coding problem in the Fourier domain. More specifically, efficient convolutional sparse coding may be derived within an alternating direction method of multipliers (ADMM) framework that utilizes fast Fourier transforms (FFT) to solve the main linear system in the frequency domain. Such algorithms may enable a significant reduction in computational cost over conventional approaches by implementing a linear solver for the most critical and computationally expensive component of the conventional iterative algorithm. The theoretical computational cost of the algorithm may be reduced from O(M.sup.3N) to O(MN log N), where N is the dimensionality of the data and M is the number of elements in the dictionary. This significant improvement in efficiency may greatly increase the range of problems that can practically be addressed via convolutional sparse representations.

  16. Converter of a continuous code into the Grey code

    International Nuclear Information System (INIS)

    Gonchar, A.I.; TrUbnikov, V.R.

    1979-01-01

    Described is a converter of a continuous code into the Grey code used in a 12-charged precision amplitude-to-digital converter to decrease the digital component of spectrometer differential nonlinearity to +0.7% in the 98% range of the measured band. To construct the converter of a continuous code corresponding to the input signal amplitude into the Grey code used is the regularity in recycling of units and zeroes in each discharge of the Grey code in the case of a continuous change of the number of pulses of a continuous code. The converter is constructed on the elements of 155 series, the frequency of continuous code pulse passing at the converter input is 25 MHz

  17. Advance of technological innovations of electric power in 2012

    International Nuclear Information System (INIS)

    Mayumi, Akihiko; Tanaka, Masanori; Takebe, Toshiro

    2013-01-01

    Twelve companies in Japan reported on the technological innovations in 2012. The Japan Atomic Power Company mainly studied five projects; (1) control of wall thinning of the secondary system in PWR by injection of molybdic acid, (2) application of pipe test method using electromagnetic acoustic resonance to existing equipment, (3) developed high performance Co-60 crud removal resin for Tsuruga Power Station Unit 2, (4) improvement of technology for safety of core in FBR, and (5) improvement of technology for coolant of FBR by dispersing nano-particles in liquid sodium metal. Tokyo Electric Power Company developed mainly three projects; (1) the support for the mental health care activities by industry protection staff at the Fukushima Daiichi and Daini Nuclear Power Plant, (2) laboratory test method using non-radioactive cesium for performance of decontamination reagent, and (3) decontamination effects estimation code (DeConEP). Hokuriku Electric Power Company reported the operations management measures in accordance with the safety enhancement measures to Shika nuclear power station. Other nine reports are published by Hokkaido Electric Power Co., Inc. Tohoku Electric Power Co., Inc. Chubu Electric Power Co., Inc., The Kansai Electric Power Co., Inc., The Chugoku Electric Power Co., Inc., Shikoku Electric Power Co., Inc., Kyushu Electric Power Co., Inc., Okinawa Electric Power Company Inc. and J-Power. (S.Y.)

  18. Determination of the costs of the nuclear desalination using the DEEP code from IAEA

    International Nuclear Information System (INIS)

    Ramirez S, J.R.; Palacios H, J.C.; Alonso V, G.

    2005-01-01

    The desalination of seawater is being an important solution to satisfy the demands of drinking water to population's centers that have hydric resources very limited, like it is the case of some Arab countries and arid regions of the planet, in where they have settled desalination plants that use as energy source to those fossil fuels or nuclear energy plants. Taking into account that the desalination of seawater is a process that consumes a lot of thermal and/or electric energy, it is necessary to quantify the costs of the supply and that of the desalination plant for different options and technologies, looking for this way the but appropriate for the specific conditions of the region where it has planned the desalination of seawater. In this report the three technologies but promising for the desalination are described and by means of the DEEP code the costs of production of water and energy are evaluated, using as thermal source different types of power nuclear reactors. It was obtained according to DEEP that the costs of the electricity generation for the considered reactors are around 40 USD/MWh. With these costs of electric power generation and using the DEEP code is obtained that the costs of production of drinking water are around 1 USD/m 3 . (Author)

  19. Dynamics of electricity efficiency in commercial air-distribution systems in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Christiansson, Lena

    1996-04-01

    This paper illustrates the long-term potential for reducing future electricity demand for air-distribution in commercial buildings in Sweden. The objective has been to develop a general quantitative scenario-based framework to describe some possible paths for electricity demand for air distribution and to analyze how governmental and utility-sponsored policy measures can affect electricity demand. The focus is on improved electricity efficiency, i.e. a reduction of electricity demand for the same level of services. The results suggest that higher electricity prices will not be very effective in reducing electricity demand, whereas significant electricity savings can be reached by implementing various policy programs, particularly standards. 56 refs, 4 figs, 5 tabs

  20. Crosstalk eliminating and low-density parity-check codes for photochromic dual-wavelength storage

    Science.gov (United States)

    Wang, Meicong; Xiong, Jianping; Jian, Jiqi; Jia, Huibo

    2005-01-01

    Multi-wavelength storage is an approach to increase the memory density with the problem of crosstalk to be deal with. We apply Low Density Parity Check (LDPC) codes as error-correcting codes in photochromic dual-wavelength optical storage based on the investigation of LDPC codes in optical data storage. A proper method is applied to reduce the crosstalk and simulation results show that this operation is useful to improve Bit Error Rate (BER) performance. At the same time we can conclude that LDPC codes outperform RS codes in crosstalk channel.