WorldWideScience

Sample records for cochlear amplification outer

  1. Progressive age-dependence and frequency difference in the effect of gap junctions on active cochlear amplification and hearing.

    Science.gov (United States)

    Zong, Liang; Chen, Jin; Zhu, Yan; Zhao, Hong-Bo

    2017-07-22

    Mutations of Connexin 26 (Cx26, GJB2), which is a predominant gap junction isoform in the cochlea, can induce high incidence of nonsyndromic hearing loss. We previously found that targeted-deletion of Cx26 in supporting Deiters cells and outer pillar cells in the cochlea can influence outer hair cell (OHC) electromotility and reduce active cochlear amplification leading to hearing loss, even though there are no gap junction connexin expressions in the auditory sensory hair cells. Here, we further report that hearing loss and the reduction of active amplification in the Cx26 targeted-deletion mice are progressive and different at high and low frequency regions, first occurring in the high frequency region and then progressively extending to the middle and low frequency regions with mouse age increased. The speed of hearing loss extending was fast in the basal high frequency region and slow in the apical low frequency region, showing a logarithmic function with mouse age. Before postnatal day 25, there were no significant hearing loss and the reduction of active cochlear amplification in the low frequency region. Hearing loss and the reduction of active cochlear amplification also had frequency difference, severe and large in the high frequency regions. These new data indicate that the effect of gap junction on active cochlear amplification is progressive, but, consistent with our previous report, exists in both high and low frequency regions in adulthood. These new data also suggest that cochlear gap junctions may have an important role in age-related hearing loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Artificial Cochlear Sensory Epithelium with Functions of Outer Hair Cells Mimicked Using Feedback Electrical Stimuli

    Directory of Open Access Journals (Sweden)

    Tetsuro Tsuji

    2018-05-01

    Full Text Available We report a novel vibration control technique of an artificial auditory cochlear epithelium that mimics the function of outer hair cells in the organ of Corti. The proposed piezoelectric and trapezoidal membrane not only has the acoustic/electric conversion and frequency selectivity of the previous device developed mainly by one of the authors and colleagues, but also has a function to control local vibration according to sound stimuli. Vibration control is achieved by applying local electrical stimuli to patterned electrodes on an epithelium made using micro-electro-mechanical system technology. By choosing appropriate phase differences between sound and electrical stimuli, it is shown that it is possible to both amplify and dampen membrane vibration, realizing better control of the response of the artificial cochlea. To be more specific, amplification and damping are achieved when the phase difference between the membrane vibration by sound stimuli and electrical stimuli is zero and π , respectively. We also demonstrate that the developed control system responds automatically to a change in sound frequency. The proposed technique can be applied to mimic the nonlinear response of the outer hair cells in a cochlea, and to realize a high-quality human auditory system.

  3. Static length changes of cochlear outer hair cells can tune low-frequency hearing.

    Directory of Open Access Journals (Sweden)

    Nikola Ciganović

    2018-01-01

    Full Text Available The cochlea not only transduces sound-induced vibration into neural spikes, it also amplifies weak sound to boost its detection. Actuators of this active process are sensory outer hair cells in the organ of Corti, whereas the inner hair cells transduce the resulting motion into electric signals that propagate via the auditory nerve to the brain. However, how the outer hair cells modulate the stimulus to the inner hair cells remains unclear. Here, we combine theoretical modeling and experimental measurements near the cochlear apex to study the way in which length changes of the outer hair cells deform the organ of Corti. We develop a geometry-based kinematic model of the apical organ of Corti that reproduces salient, yet counter-intuitive features of the organ's motion. Our analysis further uncovers a mechanism by which a static length change of the outer hair cells can sensitively tune the signal transmitted to the sensory inner hair cells. When the outer hair cells are in an elongated state, stimulation of inner hair cells is largely inhibited, whereas outer hair cell contraction leads to a substantial enhancement of sound-evoked motion near the hair bundles. This novel mechanism for regulating the sensitivity of the hearing organ applies to the low frequencies that are most important for the perception of speech and music. We suggest that the proposed mechanism might underlie frequency discrimination at low auditory frequencies, as well as our ability to selectively attend auditory signals in noisy surroundings.

  4. [Identification and analysis of the proteins interacted with Prestin in cochlear outer hair cells of guinea pig].

    Science.gov (United States)

    Luo, X; Wang, J Y; Zhang, F L; Xia, Y

    2018-01-07

    Objective: To explore the regulation and mechanism of Prestin protein by identifying the proteins interacted with Prestin in cochlear outer hair cell(OHC) and analyzing their biological function. Methods: Co-immunoprecipitation combined mass spectrometry technology was used to isolate and identify the proteins interacted with Prestin protein of OHC, bioinformatics was used to construct Prestin protein interaction network. The proteins interacted with Prestin in OHC of guinea pig were determined by matching primary interaction mass spectrometry with protein interaction network, and annotated their functions. Results: The results of co-immunoprecipitation combined with mass spectrometry showed that 116 kinds of credible proteins could interact with Prestin. By constructing Prestin protein interaction network, matching the results of mass spectrometry and analyzing of sub-cellular localization, eight kinds of proteins were confirmed that they interacted with Prestin directly, namely EEF2, HSP90AB1, FN1, FLNA, EEF1A1, HSP90B1, ATP5A1, and ERH, respectively, which were mainly involved in the synthesis and transportation, transmembrane folding and localization, structural stability and signal transduction of Prestin protein. Conclusion: EEF2, HSP90AB1, FN1, FLNA, EEF1A1, HSP90B1, ATP5A1 and ERH provide molecular basis for sensory amplification function of OHCs by participating in biotransformation, transmembrane folding and localization, signal transduction and other biological processes of Prestin protein.

  5. Gain and frequency tuning within the mouse cochlear apex

    Energy Technology Data Exchange (ETDEWEB)

    Oghalai, John S.; Raphael, Patrick D. [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Gao, Simon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Bioengineering, Rice University, Houston, Texas (United States); Lee, Hee Yoon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Electrical Engineering, Stanford University, Stanford, California (United States); Groves, Andrew K. [Department of Neuroscience, Department of Molecular and Human Genetics, and Program in Developmental Biology, Baylor College of Medicine, Houston, Texas (United States); Zuo, Jian [Department of Developmental Neurobiology, St. Jude Children’s Research Hospital, Memphis, Tennessee (United States); Applegate, Brian E. [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States)

    2015-12-31

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.

  6. Gain and frequency tuning within the mouse cochlear apex

    International Nuclear Information System (INIS)

    Oghalai, John S.; Raphael, Patrick D.; Gao, Simon; Lee, Hee Yoon; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.

    2015-01-01

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering

  7. miR-96 regulates the progression of differentiation in mammalian cochlear inner and outer hair cells.

    Science.gov (United States)

    Kuhn, Stephanie; Johnson, Stuart L; Furness, David N; Chen, Jing; Ingham, Neil; Hilton, Jennifer M; Steffes, Georg; Lewis, Morag A; Zampini, Valeria; Hackney, Carole M; Masetto, Sergio; Holley, Matthew C; Steel, Karen P; Marcotti, Walter

    2011-02-08

    MicroRNAs (miRNAs) are small noncoding RNAs able to regulate a broad range of protein-coding genes involved in many biological processes. miR-96 is a sensory organ-specific miRNA expressed in the mammalian cochlea during development. Mutations in miR-96 cause nonsyndromic progressive hearing loss in humans and mice. The mouse mutant diminuendo has a single base change in the seed region of the Mir96 gene leading to widespread changes in the expression of many genes. We have used this mutant to explore the role of miR-96 in the maturation of the auditory organ. We found that the physiological development of mutant sensory hair cells is arrested at around the day of birth, before their biophysical differentiation into inner and outer hair cells. Moreover, maturation of the hair cell stereocilia bundle and remodelling of auditory nerve connections within the cochlea fail to occur in miR-96 mutants. We conclude that miR-96 regulates the progression of the physiological and morphological differentiation of cochlear hair cells and, as such, coordinates one of the most distinctive functional refinements of the mammalian auditory system.

  8. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    Science.gov (United States)

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.

  9. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  10. The actin-binding proteins eps8 and gelsolin have complementary roles in regulating the growth and stability of mechanosensory hair bundles of mammalian cochlear outer hair cells.

    Directory of Open Access Journals (Sweden)

    Jennifer Olt

    Full Text Available Sound transduction depends upon mechanosensitive channels localized on the hair-like bundles that project from the apical surface of cochlear hair cells. Hair bundles show a stair-case structure composed of rows of stereocilia, and each stereocilium contains a core of tightly-packed and uniformly-polarized actin filaments. The growth and maintenance of the stereociliary actin core are dynamically regulated. Recently, it was shown that the actin-binding protein gelsolin is expressed in the stereocilia of outer hair cells (OHCs and in its absence they become long and straggly. Gelsolin is part of a whirlin scaffolding protein complex at the stereocilia tip, which has been shown to interact with other actin regulatory molecules such as Eps8. Here we investigated the physiological effects associated with the absence of gelsolin and its possible overlapping role with Eps8. We found that, in contrast to Eps8, gelsolin does not affect mechanoelectrical transduction during immature stages of development. Moreover, OHCs from gelsolin knockout mice were able to mature into fully functional sensory receptors as judged by the normal resting membrane potential and basolateral membrane currents. Mechanoelectrical transducer current in gelsolin-Eps8 double knockout mice showed a profile similar to that observed in the single mutants for Eps8. We propose that gelsolin has a non-overlapping role with Eps8. While Eps8 is mainly involved in the initial growth of stereocilia in both inner hair cells (IHCs and OHCs, gelsolin is required for the maintenance of mature hair bundles of low-frequency OHCs after the onset of hearing.

  11. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  12. Genomic DNA fingerprinting of clinical Haemophilus influenzae isolates by polymerase chain reaction amplification: comparison with major outer-membrane protein and restriction fragment length polymorphism analysis

    NARCIS (Netherlands)

    van Belkum, A.; Duim, B.; Regelink, A.; Möller, L.; Quint, W.; van Alphen, L.

    1994-01-01

    Non-capsulate strains of Haemophilus influenzae were genotyped by analysis of variable DNA segments obtained by amplification of genomic DNA with the polymerase chain reaction (PCR fingerprinting). Discrete fragments of 100-2000 bp were obtained. The reproducibility of the procedure was assessed by

  13. ILDR1 deficiency causes degeneration of cochlear outer hair cells and disrupts the structure of the organ of Corti: a mouse model for human DFNB42

    Directory of Open Access Journals (Sweden)

    Qing Sang

    2015-03-01

    Full Text Available Immunoglobulin-like domain containing receptor 1 (ILDR1 is a poorly characterized gene that was first identified in lymphoma cells. Mutations in ILDR1 are responsible for DFNB42, but the pathogenesis of hearing loss caused by ILDR1 mutations remains to be elucidated. To explore the role of ILDR1 in hearing, we created Ildr1 knockout mice. In heterozygous mice, ILDR1 expression was found in outer hair cells (OHCs and inner hair cells (IHCs of the organ of Corti. ILDR1-deficient mice are profoundly deaf by postnatal day 21 (P21. No significant difference was observed in the supporting cells and IHCs of ILDR1-deficient mice, but progressive degeneration of OHCs occurred at P15 and disruption of the tunnel running through the organ of Corti was noticeable at P21. By P28, there were no OHCs visible in any of the turns of the organ of Corti, and the tunnel of the organ of Corti was entirely destroyed. ILDR1 deficiency affects expression of tricellulin in vivo, and this provides a possible explanation to hearing loss. To further elucidate the mechanism of deafness related to ILDR1 deficiency, we pursued a differential proteomic approach to comprehensively assess differential protein expression in the cochleae of Ildr1+/− and Ildr1−/− mice at P21. Altogether, 708 proteins were up-regulated (fold change >1.5 and 114 proteins were down-regulated (fold change <0.5 in the Ildr1−/− mice compared with Ildr1+/− mice. Gene ontology classification indicated that a number of differentially expressed proteins are involved in cell adhesion, protein and vesicle-mediated transport, cell death, membrane organization, and cellular homeostasis. A few of these proteins are closely related to hearing development. Taken together, our data suggest that ILDR1 is important for the survival of OHCs and provide novel insights into the pathogenesis of human deafness DFNB42 deafness.

  14. Cochlear implant: what the radiologist should know

    International Nuclear Information System (INIS)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira

    2013-01-01

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  15. Cochlear implant: what the radiologist should know

    Directory of Open Access Journals (Sweden)

    Natalia Delage Gomes

    2013-06-01

    Full Text Available Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

  16. Mechanoelectrical transduction of adult outer hair cells studied in a gerbil hemicochlea.

    Science.gov (United States)

    He, David Z Z; Jia, Shuping; Dallos, Peter

    2004-06-17

    Sensory receptor cells of the mammalian cochlea are morphologically and functionally dichotomized. Inner hair cells transmit auditory information to the brain, whereas outer hair cells (OHC) amplify the mechanical signal, which is then transduced by inner hair cells. Amplification by OHCs is probably mediated by their somatic motility in a mechanical feedback process. OHC motility in vivo is thought to be driven by the cell's receptor potential. The first steps towards the generation of the receptor potential are the deflection of the stereociliary bundle, and the subsequent flow of transducer current through the mechanosensitive transducer channels located at their tips. Quantitative relations between transducer currents and basilar membrane displacements are lacking, as well as their variation along the cochlear length. To address this, we simultaneously recorded OHC transducer currents (or receptor potentials) and basilar membrane motion in an excised and bisected cochlea, the hemicochlea. This preparation permits recordings from adult OHCs at various cochlear locations while the basilar membrane is mechanically stimulated. Furthermore, the stereocilia are deflected by the same means of stimulation as in vivo. Here we show that asymmetrical transducer currents and receptor potentials are significantly larger than previously thought, they possess a highly restricted dynamic range and strongly depend on cochlear location.

  17. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  18. Chronic Conductive Hearing Loss Leads to Cochlear Degeneration.

    Science.gov (United States)

    Liberman, M Charles; Liberman, Leslie D; Maison, Stéphane F

    2015-01-01

    Synapses between cochlear nerve terminals and hair cells are the most vulnerable elements in the inner ear in both noise-induced and age-related hearing loss, and this neuropathy is exacerbated in the absence of efferent feedback from the olivocochlear bundle. If age-related loss is dominated by a lifetime of exposure to environmental sounds, reduction of acoustic drive to the inner ear might improve cochlear preservation throughout life. To test this, we removed the tympanic membrane unilaterally in one group of young adult mice, removed the olivocochlear bundle in another group and compared their cochlear function and innervation to age-matched controls one year later. Results showed that tympanic membrane removal, and the associated threshold elevation, was counterproductive: cochlear efferent innervation was dramatically reduced, especially the lateral olivocochlear terminals to the inner hair cell area, and there was a corresponding reduction in the number of cochlear nerve synapses. This loss led to a decrease in the amplitude of the suprathreshold cochlear neural responses. Similar results were seen in two cases with conductive hearing loss due to chronic otitis media. Outer hair cell death was increased only in ears lacking medial olivocochlear innervation following olivocochlear bundle cuts. Results suggest the novel ideas that 1) the olivocochlear efferent pathway has a dramatic use-dependent plasticity even in the adult ear and 2) a component of the lingering auditory processing disorder seen in humans after persistent middle-ear infections is cochlear in origin.

  19. Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral

    Science.gov (United States)

    Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.

    2012-01-01

    Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353

  20. Outer magnetosphere

    International Nuclear Information System (INIS)

    Schardt, A.W.; Behannon, K.W.; Lepping, R.P.; Carbary, J.F.; Eviatar, A.; Siscoe, G.L.

    1984-01-01

    Similarities between the Saturnian and terrestrial outer magnetosphere are examined. Saturn, like earth, has a fully developed magnetic tail, 80 to 100 RS in diameter. One major difference between the two outer magnetospheres is the hydrogen and nitrogen torus produced by Titan. This plasma is, in general, convected in the corotation direction at nearly the rigid corotation speed. Energies of magnetospheric particles extend to above 500 keV. In contrast, interplanetary protons and ions above 2 MeV have free access to the outer magnetosphere to distances well below the Stormer cutoff. This access presumably occurs through the magnetotail. In addition to the H+, H2+, and H3+ ions primarily of local origin, energetic He, C, N, and O ions are found with solar composition. Their flux can be substantially enhanced over that of interplanetary ions at energies of 0.2 to 0.4 MeV/nuc

  1. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  2. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  3. GENOMIC DNA-FINGERPRINTING OF CLINICAL HAEMOPHILUS-INFLUENZAE ISOLATES BY POLYMERASE CHAIN-REACTION AMPLIFICATION - COMPARISON WITH MAJOR OUTER-MEMBRANE PROTEIN AND RESTRICTION-FRAGMENT-LENGTH-POLYMORPHISM ANALYSIS

    NARCIS (Netherlands)

    VANBELKUM, A; DUIM, B; REGELINK, A; MOLLER, L; QUINT, W; VANALPHEN, L

    Non-capsulate strains of Haemophilus influenzae were genotyped by analysis of variable DNA segments obtained by amplification of genomic DNA with the polymerase chain reaction (PCR fingerprinting). Discrete fragments of 100-2000 bp were obtained. The reproducibility of the procedure was assessed by

  4. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  5. Protective role of hydrogen sulfide against noise-induced cochlear damage: a chronic intracochlear infusion model.

    Directory of Open Access Journals (Sweden)

    Xu Li

    Full Text Available BACKGROUND: A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL. The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2S has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2S in cochlear blood flow regulation and noise protection. METHODOLOGY/PRINCIPAL FINDINGS: The gene and protein expression of the H(2S synthetase cystathionine-γ-lyase (CSE in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP, NaHS or DL-propargylglycine (PPG were locally administered. Local sodium hydrosulfide (NaHS significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR, cochlear scanning electron microscope (SEM and outer hair cell (OHC count. The highest percentage of OHC loss occurred in the PPG group. CONCLUSIONS/SIGNIFICANCE: Our results suggest that H(2S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.

  6. The Effects of Urethane on Rat Outer Hair Cells

    Directory of Open Access Journals (Sweden)

    Mingyu Fu

    2016-01-01

    Full Text Available The cochlea converts sound vibration into electrical impulses and amplifies the low-level sound signal. Urethane, a widely used anesthetic in animal research, has been shown to reduce the neural responses to auditory stimuli. However, the effects of urethane on cochlea, especially on the function of outer hair cells, remain largely unknown. In the present study, we compared the cochlear microphonic responses between awake and urethane-anesthetized rats. The results revealed that the amplitude of the cochlear microphonic was decreased by urethane, resulting in an increase in the threshold at all of the sound frequencies examined. To deduce the possible mechanism underlying the urethane-induced decrease in cochlear sensitivity, we examined the electrical response properties of isolated outer hair cells using whole-cell patch-clamp recording. We found that urethane hyperpolarizes the outer hair cell membrane potential in a dose-dependent manner and elicits larger outward current. This urethane-induced outward current was blocked by strychnine, an antagonist of the α9 subunit of the nicotinic acetylcholine receptor. Meanwhile, the function of the outer hair cell motor protein, prestin, was not affected. These results suggest that urethane anesthesia is expected to decrease the responses of outer hair cells, whereas the frequency selectivity of cochlea remains unchanged.

  7. Effect of cochlear nerve electrocautery on the adult cochlear nucleus.

    Science.gov (United States)

    Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A

    2015-04-01

    Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.

  8. Cochlear implant: what the radiologist should know; Implante coclear: o que o radiologista precisa saber

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira, E-mail: nataliadelagegomes@gmail.com [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unidade de Radiologia e Diagnostico por Imagem

    2013-05-15

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  9. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  10. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  11. Modelling Cochlear Mechanics

    Directory of Open Access Journals (Sweden)

    Guangjian Ni

    2014-01-01

    Full Text Available The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM. Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling.

  12. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  13. A synthetic prestin reveals protein domains and molecular operation of outer hair cell piezoelectricity.

    Science.gov (United States)

    Schaechinger, Thorsten J; Gorbunov, Dmitry; Halaszovich, Christian R; Moser, Tobias; Kügler, Sebastian; Fakler, Bernd; Oliver, Dominik

    2011-06-24

    Prestin, a transporter-like protein of the SLC26A family, acts as a piezoelectric transducer that mediates the fast electromotility of outer hair cells required for cochlear amplification and auditory acuity in mammals. Non-mammalian prestin orthologues are anion transporters without piezoelectric activity. Here, we generated synthetic prestin (SynPres), a chimera of mammalian and non-mammalian prestin exhibiting both, piezoelectric properties and anion transport. SynPres delineates two distinct domains in the protein's transmembrane core that are necessary and sufficient for generating electromotility and associated non-linear charge movement (NLC). Functional analysis of SynPres showed that the amplitude of NLC and hence electromotility are determined by the transport of monovalent anions. Thus, prestin-mediated electromotility is a dual-step process: transport of anions by an alternate access cycle, followed by an anion-dependent transition generating electromotility. The findings define structural and functional determinants of prestin's piezoelectric activity and indicate that the electromechanical process evolved from the ancestral transport mechanism.

  14. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2007-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ; SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and

  15. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2010-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ;SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and can

  16. Cochlear changes in presbycusis with tinnitus.

    Science.gov (United States)

    Terao, Kyoichi; Cureoglu, Sebahattin; Schachern, Patricia A; Morita, Norimasa; Nomiya, Shigenobu; Deroee, Armin F; Doi, Katsumi; Mori, Kazunori; Murata, Kiyotaka; Paparella, Michael M

    2011-01-01

    The pathophysiology of tinnitus is obscure and its treatment is therefore elusive. Significant progress in this field can only be achieved by determining the mechanisms of tinnitus generation, and thus, histopathologic findings of the cochlea in presbycusis with tinnitus become crucial. We revealed the histopathologic findings of the cochlea in subjects with presbycusis and tinnitus. The subjects were divided into 2 groups, presbycusis with tinnitus (tinnitus) group and presbycusis without tinnitus (control) group, with each group comprising 8 temporal bones from 8 subjects. We quantitatively analyzed the number of spiral ganglion cells, loss of cochlear inner and outer hair cells, and areas of the stria vascularis and spiral ligament. There was a significantly greater loss of outer hair cells in the tinnitus group compared with the control group in the basal and upper middle turns. The stria vascularis was more atrophic in the tinnitus group compared with the control group in the basal turn. Tinnitus is more common in patients with presbycusis who have more severe degeneration of outer hair cells and stria vascularis. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  18. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  19. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  20. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  1. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  2. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  3. Localization of the cochlear amplifier in living sensitive ears.

    Directory of Open Access Journals (Sweden)

    Tianying Ren

    Full Text Available BACKGROUND: To detect soft sounds, the mammalian cochlea increases its sensitivity by amplifying incoming sounds up to one thousand times. Although the cochlear amplifier is thought to be a local cellular process at an area basal to the response peak on the spiral basilar membrane, its location has not been demonstrated experimentally. METHODOLOGY AND PRINCIPAL FINDINGS: Using a sensitive laser interferometer to measure sub-nanometer vibrations at two locations along the basilar membrane in sensitive gerbil cochleae, here we show that the cochlea can boost soft sound-induced vibrations as much as 50 dB/mm at an area proximal to the response peak on the basilar membrane. The observed amplification works maximally at low sound levels and at frequencies immediately below the peak-response frequency of the measured apical location. The amplification decreases more than 65 dB/mm as sound levels increases. CONCLUSIONS AND SIGNIFICANCE: We conclude that the cochlea amplifier resides at a small longitudinal region basal to the response peak in the sensitive cochlea. These data provides critical information for advancing our knowledge on cochlear mechanisms responsible for the remarkable hearing sensitivity, frequency selectivity and dynamic range.

  4. Influence of hearing age and understanding verbal instructions in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Đoković Sanja

    2013-01-01

    Full Text Available Hearing age is defined as a period of using any amplification. Most researches indicate that hearing age influences the developmental rate of auditory and speech-language abilities in deaf children, especially when cochlear implantation was performed before the age of three. This research is aimed at analyzing the influence of hearing age on understanding verbal instructions in children with cochlear implants. The sample consists of 23 children with cochlear implants and 21 children with normal hearing, aged between 4 and 10. Hearing age of children with cochlear implants was between 2 and 7 years. Token Test with toys, adapted for children with hearing impairments, was used to analyze understanding verbal instructions. The results indicate that there are statistically significant differences between children with cochlear implants and children with normal hearing, aged between 4 and 7, on all subtests and the total score regardless of the hearing age (sub1 p<0.001, sub2 p<0.000, sub3 p<0.001, total score p<0.000. No statistically significant differences were determined on any of the subtests in children aged between 7.1 and 10, regardless of the hearing age. Comparative results analysis within the experimental group of children with different hearing age indicates that the difference in understanding verbal instructions between these two groups is not statistically significant.

  5. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  6. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  8. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  9. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  10. Stria vascularis and cochlear hair cell changes in syphilis: A human temporal bone study.

    Science.gov (United States)

    Hızlı, Ömer; Kaya, Serdar; Hızlı, Pelin; Paparella, Michael M; Cureoglu, Sebahattin

    2016-12-01

    To observe any changes in stria vascularis and cochlear hair cells in patients with syphilis. We examined 13 human temporal bone samples from 8 patients with syphilis (our syphilis group), as well as 12 histopathologically normal samples from 9 age-matched patients without syphilis (our control group). We compared, between the two groups, the mean area of the stria vascularis (measured with conventional light microscopy connected to a personal computer) and the mean percentage of cochlear hair cell loss (obtained from cytocochleograms). In our syphilis group, only 1 (7.7%) of the 13 samples had precipitate in the endolymphatic or perilymphatic spaces; 8 (61.5%) of the samples revealed the presence of endolymphatic hydrops (4 cochlear, 4 saccular). The mean area of the stria vascularis did not significantly differ, in any turn of the cochlea, between the 2 groups (P>0.1). However, we did find significant differences between the 2 groups in the mean percentage of outer hair cells in the apical turn (Psyphilis group, we observed either complete loss of the organ of Corti or a flattened organ of Corti without any cells in addition to the absence of both outer and inner hair cells. In this study, syphilis led either to complete loss of the organ of Corti or to significant loss of cochlear hair cells, in addition to cochleosaccular hydrops. But the area of the stria vascularis did not change. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  12. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  13. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  14. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  15. Medial Olivocochlear Reflex Interneurons Are Located in the Posteroventral Cochlear Nucleus: A Kainic Acid Lesion Study in Guinea Pigs

    OpenAIRE

    De VENECIA, RONALD K.; LIBERMAN, M. CHARLES; GUINAN, JOHN J.; BROWN, M. CHRISTIAN

    2005-01-01

    The medial olivocochlear (MOC) reflex arc is probably a three-neuron pathway consisting of type I spiral ganglion neurons, reflex interneurons in the cochlear nucleus, and MOC neurons that project to the outer hair cells of the cochlea. We investigated the identity of MOC reflex interneurons in the cochlear nucleus by assaying their regional distribution using focal injections of kainic acid. Our reflex metric was the amount of change in the distortion product otoacoustic emission (at 2f1–f2)...

  16. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. The Outer Space Treaty

    Science.gov (United States)

    Johnson, Christopher Daniel

    2018-01-01

    Negotiated at the United Nations and in force since 1967, the Outer Space Treaty has been ratified by over 100 countries and is the most important and foundational source of space law. The treaty, whose full title is "Treaty on Principles Governing the Activities of States in the Exploration and Use of Outer Space, Including the Moon and Other Celestial Bodies," governs all of humankind's activities in outer space, including activities on other celestial bodies and many activities on Earth related to outer space. All space exploration and human spaceflight, planetary sciences, and commercial uses of space—such as the global telecommunications industry and the use of space technologies such as position, navigation, and timing (PNT), take place against the backdrop of the general regulatory framework established in the Outer Space Treaty. A treaty is an international legal instrument which balances rights and obligations between states, and exists as a kind of mutual contract of shared understandings, rights, and responsibilities between them. Negotiated and drafted during the Cold War era of heightened political tensions, the Outer Space Treaty is largely the product of efforts by the United States and the USSR to agree on certain minimum standards and obligations to govern their competition in "conquering" space. Additionally, the Outer Space Treaty is similar to other treaties, including treaties governing the high seas, international airspace, and the Antarctic, all of which govern the behavior of states outside of their national borders. The treaty is brief in nature and only contains 17 articles, and is not comprehensive in addressing and regulating every possible scenario. The negotiating states knew that the Outer Space Treaty could only establish certain foundational concepts such as freedom of access, state responsibility and liability, non-weaponization of space, the treatment of astronauts in distress, and the prohibition of non-appropriation of

  18. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  19. Saturn's outer magnetosphere

    Science.gov (United States)

    Schardt, A. W.; Behannon, K. W.; Carbary, J. F.; Eviatar, A.; Lepping, R. P.; Siscoe, G. L.

    1983-01-01

    Similarities between the Saturnian and terrestrial outer magnetosphere are examined. Saturn, like Earth, has a fully developed magnetic tail, 80 to 100 RS in diameter. One major difference between the two outer magnetospheres is the hydrogen and nitrogen torus produced by Titan. This plasma is, in general, convected in the corotation direction at nearly the rigid corotation speed. Energies of magnetospheric particles extend to above 500 keV. In contrast, interplanetary protons and ions above 2 MeV have free access to the outer magnetosphere to distances well below the Stormer cutoff. This access presumably occurs through the magnetotail. In addition to the H+, H2+, and H3+ ions primarily of local origin, energetic He, C, N, and O ions are found with solar composition. Their flux can be substantially enhanced over that of interplanetary ions at energies of 0.2 to 0.4 MeV/nuc.

  20. Microanatomy of the cochlear hook

    Science.gov (United States)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  1. Serotonin projection patterns to the cochlear nucleus.

    Science.gov (United States)

    Thompson, A M; Thompson, G C

    2001-07-13

    The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the

  2. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  3. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Gene amplification in carcinogenesis

    Directory of Open Access Journals (Sweden)

    Lucimari Bizari

    2006-01-01

    Full Text Available Gene amplification increases the number of genes in a genome and can give rise to karyotype abnormalities called double minutes (DM and homogeneously staining regions (HSR, both of which have been widely observed in human tumors but are also known to play a major role during embryonic development due to the fact that they are responsible for the programmed increase of gene expression. The etiology of gene amplification during carcinogenesis is not yet completely understood but can be considered a result of genetic instability. Gene amplification leads to an increase in protein expression and provides a selective advantage during cell growth. Oncogenes such as CCND1, c-MET, c-MYC, ERBB2, EGFR and MDM2 are amplified in human tumors and can be associated with increased expression of their respective proteins or not. In general, gene amplification is associated with more aggressive tumors, metastases, resistance to chemotherapy and a decrease in the period during which the patient stays free of the disease. This review discusses the major role of gene amplification in the progression of carcinomas, formation of genetic markers and as possible therapeutic targets for the development of drugs for the treatment of some types of tumors.

  5. The Influence of Cochlear Mechanical Dysfunction, Temporal Processing Deficits, and Age on the Intelligibility of Audible Speech in Noise for Hearing-Impaired Listeners

    Directory of Open Access Journals (Sweden)

    Peter T. Johannesen

    2016-05-01

    Full Text Available The aim of this study was to assess the relative importance of cochlear mechanical dysfunction, temporal processing deficits, and age on the ability of hearing-impaired listeners to understand speech in noisy backgrounds. Sixty-eight listeners took part in the study. They were provided with linear, frequency-specific amplification to compensate for their audiometric losses, and intelligibility was assessed for speech-shaped noise (SSN and a time-reversed two-talker masker (R2TM. Behavioral estimates of cochlear gain loss and residual compression were available from a previous study and were used as indicators of cochlear mechanical dysfunction. Temporal processing abilities were assessed using frequency modulation detection thresholds. Age, audiometric thresholds, and the difference between audiometric threshold and cochlear gain loss were also included in the analyses. Stepwise multiple linear regression models were used to assess the relative importance of the various factors for intelligibility. Results showed that (a cochlear gain loss was unrelated to intelligibility, (b residual cochlear compression was related to intelligibility in SSN but not in a R2TM, (c temporal processing was strongly related to intelligibility in a R2TM and much less so in SSN, and (d age per se impaired intelligibility. In summary, all factors affected intelligibility, but their relative importance varied across maskers.

  6. Social amplification of risk

    International Nuclear Information System (INIS)

    Kasperson, R.E.; Renn, O.; Slovic, P.; Kasperson, J.X.; Emani, S.

    1989-01-01

    The risks associated with radioactive and other hazardous waste disposal may be expected to interact with societal processes to enlarge or attenuate the consequences of risks and risk events. This article summarizes a conceptual framework that depicts the social amplification of risk. Using a data base of 128 hazard events that have occurred largely over the past ten years, the authors examine the role of physical consequences, media coverage, and public perceptions of risk in generating social and economic impacts. The analysis concludes that social amplification processes substantially shape the nature and magnitude of those impacts but also that such social amplification appears to be systematically related to characteristics of the risks and risk events

  7. Energy flow in passive and active 3D cochlear model

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanli; Steele, Charles [Department of Mechanical Engineering, Stanford University, Stanford, California (United States); Puria, Sunil [Department of Mechanical Engineering, Stanford University, Stanford, California (United States); Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, California (United States)

    2015-12-31

    Energy flow in the cochlea is an important characteristic of the cochlear traveling wave, and many investigators, such as von Békésy and Lighthill, have discussed this phenomenon. Particularly after the discovery of the motility of the outer hair cells (OHCs), the nature of the power gain of the cochlea has been a fundamental research question. In the present work, direct three-dimensional (3D) calculations of the power on cross sections of the cochlea and on the basilar membrane are performed based on a box model of the mouse cochlea. The distributions of the fluid pressure and fluid velocity in the scala vestibuli are presented. The power output from the OHCs and the power loss due to fluid viscous damping are calculated along the length of the cochlea. This work provides a basis for theoretical calculations of the power gain of the OHCs from mechanical considerations.

  8. Energy flow in passive and active 3D cochlear model

    International Nuclear Information System (INIS)

    Wang, Yanli; Steele, Charles; Puria, Sunil

    2015-01-01

    Energy flow in the cochlea is an important characteristic of the cochlear traveling wave, and many investigators, such as von Békésy and Lighthill, have discussed this phenomenon. Particularly after the discovery of the motility of the outer hair cells (OHCs), the nature of the power gain of the cochlea has been a fundamental research question. In the present work, direct three-dimensional (3D) calculations of the power on cross sections of the cochlea and on the basilar membrane are performed based on a box model of the mouse cochlea. The distributions of the fluid pressure and fluid velocity in the scala vestibuli are presented. The power output from the OHCs and the power loss due to fluid viscous damping are calculated along the length of the cochlea. This work provides a basis for theoretical calculations of the power gain of the OHCs from mechanical considerations

  9. A FPGA Implementation of the CAR-FAC Cochlear Model

    Directory of Open Access Journals (Sweden)

    Ying Xu

    2018-04-01

    Full Text Available This paper presents a digital implementation of the Cascade of Asymmetric Resonators with Fast-Acting Compression (CAR-FAC cochlear model. The CAR part simulates the basilar membrane's (BM response to sound. The FAC part models the outer hair cell (OHC, the inner hair cell (IHC, and the medial olivocochlear efferent system functions. The FAC feeds back to the CAR by moving the poles and zeros of the CAR resonators automatically. We have implemented a 70-section, 44.1 kHz sampling rate CAR-FAC system on an Altera Cyclone V Field Programmable Gate Array (FPGA with 18% ALM utilization by using time-multiplexing and pipeline parallelizing techniques and present measurement results here. The fully digital reconfigurable CAR-FAC system is stable, scalable, easy to use, and provides an excellent input stage to more complex machine hearing tasks such as sound localization, sound segregation, speech recognition, and so on.

  10. A FPGA Implementation of the CAR-FAC Cochlear Model.

    Science.gov (United States)

    Xu, Ying; Thakur, Chetan S; Singh, Ram K; Hamilton, Tara Julia; Wang, Runchun M; van Schaik, André

    2018-01-01

    This paper presents a digital implementation of the Cascade of Asymmetric Resonators with Fast-Acting Compression (CAR-FAC) cochlear model. The CAR part simulates the basilar membrane's (BM) response to sound. The FAC part models the outer hair cell (OHC), the inner hair cell (IHC), and the medial olivocochlear efferent system functions. The FAC feeds back to the CAR by moving the poles and zeros of the CAR resonators automatically. We have implemented a 70-section, 44.1 kHz sampling rate CAR-FAC system on an Altera Cyclone V Field Programmable Gate Array (FPGA) with 18% ALM utilization by using time-multiplexing and pipeline parallelizing techniques and present measurement results here. The fully digital reconfigurable CAR-FAC system is stable, scalable, easy to use, and provides an excellent input stage to more complex machine hearing tasks such as sound localization, sound segregation, speech recognition, and so on.

  11. TPS for Outer Planets

    Science.gov (United States)

    Venkatapathy, Ethiraj; Ellerby, D.; Gage, P.; Gasch, M.; Hwang, H.; Prabhu, D.; Stackpoole, M.; Wercinski, Paul

    2018-01-01

    This invited talk will provide an assessment of the TPS needs for Outer Planet In-situ missions to destinations with atmosphere. The talk will outline the drivers for TPS from destination, science, mission architecture and entry environment. An assessment of the readiness of the TPS, both currently available and under development, for Saturn, Titan, Uranus and Neptune are provided. The challenges related to sustainability of the TPS for future missions are discussed.

  12. Motion of organ of Corti structures in the gerbil cochlear apex, measured with a commercial optical coherence tomography (OCT) system

    Science.gov (United States)

    Ravicz, Michael E.; Cho, Nam-Hyun; Maftoon, Nima; Puria, Sunil

    2018-05-01

    Recent developments in Optical Coherence Tomography (OCT) allow measurements of cochlear motions through the bony cochlear wall without holes at spatial resolutions approaching about 10 µm. Measurements to date have been made with custom OCT systems with long development times. We present measurements made with a commercial OCT system driven by custom software (VibOCT) that facilitates near real-time frequency response measurements. The 905-nm wavelength laser and high-speed (100 kHz) camera provide higher axial resolution (3 µm in air) and temporal resolution than previous studies and a sub-nanometer noise floor in air. We gathered anatomical images of the gerbil cochlear apex in vivo at higher resolution than available previously, sufficient to resolve individual outer hair cells, pillar cells, tunnel of Corti and inner sulcus regions. Images from the 3rd apical turn show a bulging of Reissners membrane in vivo that flattened post-mortem with a concomitant reduction in the distance between the Henson cell border and the stria vascularis wall. Vibrometry of the organ of Corti shows a low-pass characteristic in-vivo and post-mortem with a traveling wave-like phase delay similar to a recent study rather than the sharp tuning seen more basally. This system can provide valuable information on cochlear function, which is also useful for the development of detailed cochlear models of the passive and active gerbil apex.

  13. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.

    Science.gov (United States)

    Chung, King; McKibben, Nicholas

    2011-10-01

    Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before

  14. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  15. Outer Continental Shelf Lands Act

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data represents geographic terms used within the Outer Continental Shelf Lands Act (OCSLA or Act). The Act defines the United States outer continental shelf...

  16. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

    OpenAIRE

    Dalbert, Adrian; Pfiffner, Flurin; Hoesli, Marco; Koka, Kanthaiah; Veraguth, Dorothe; Roosli, Christof; Huber, Alexander

    2018-01-01

    Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle elec...

  17. Biomaterials in light amplification

    Science.gov (United States)

    Mysliwiec, Jaroslaw; Cyprych, Konrad; Sznitko, Lech; Miniewicz, Andrzej

    2017-03-01

    Biologically produced or inspired materials can serve as optical gain media, i.e. they can exhibit the phenomenon of light amplification. Some of these materials, under suitable dye-doping and optical pumping conditions, show lasing phenomena. The emerging branch of research focused on obtaining lasing action in highly disordered and highly light scattering materials, i.e. research on random lasing, is perfectly suited for biological materials. The use of biomaterials in light amplification has been extensively reported in the literature. In this review we attempt to report on progress in the development of biologically derived systems able to show the phenomena of light amplification and random lasing together with the contribution of our group to this field. The rich world of biopolymers modified with molecular aggregates and nanocrystals, and self-organized at the nanoscale, offers a multitude of possibilities for tailoring luminescent and light scattering properties that are not easily replicated in conventional organic or inorganic materials. Of particular importance and interest are light amplification and lasing, or random lasing studies in biological cells and tissues. In this review we will describe nucleic acids and their complexes employed as gain media due to their favorable optical properties and ease of manipulation. We will report on research conducted on various biomaterials showing structural analogy to nucleic acids such as fluorescent proteins, gelatins in which the first distributed feedback laser was realized, and also amyloids or silks, which, due to their dye-doped fiber-like structure, allow for light amplification. Other materials that were investigated in that respect include polysaccharides, like starch exhibiting favorable photostability in comparison to other biomaterials, and chitosan, which forms photonic crystals or cellulose. Light amplification and random lasing was not only observed in processed biomaterials but also in living

  18. Predicting effects of impaired cochlear processing on consonant discrimination in stationary noise

    DEFF Research Database (Denmark)

    Jepsen, Morten Løve; Dau, Torsten; Ghitza, Oded

    Cochlear hearing loss is typically associated with reduced sensitivity due to inner hair-cell (IHC) and outer hair-cell (OHC) dysfunction. OHC dysfunction also leads to supra-threshold deficits, such as reduced basilar-membrane (BM) compression as well as reduced frequency selectivity and temporal...... patterns from a Diagnostic Rhyme Test (DRT) were measured and analyzed in terms of acoustic-phonetic features. This was done for three listeners with cochlear hearing loss and at two signal-to-noise ratios. It is shown that the predicted errors patterns matched the measured patterns in most conditions......, such as the evaluation of hearing-instrument signal processing, where the effects of specific processing strategies can be simulated for individual hearing losses....

  19. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  20. Peroxynitrite induces apoptosis of mouse cochlear hair cells via a Caspase-independent pathway in vitro.

    Science.gov (United States)

    Cao, Zhixin; Yang, Qianqian; Yin, Haiyan; Qi, Qi; Li, Hongrui; Sun, Gaoying; Wang, Hongliang; Liu, Wenwen; Li, Jianfeng

    2017-11-01

    Peroxynitrite (ONOO - ) is a potent and versatile oxidant implicated in a number of pathophysiological processes. The present study was designed to investigate the effect of ONOO - on the cultured cochlear hair cells (HCs) of C57BL/6 mice in vitro as well as the possible mechanism underlying the action of such an oxidative stress. The in vitro primary cultured cochlear HCs were subjected to different concentrations of ONOO - , then, the cell survival and morphological changes were examined by immunofluorescence and transmission electron microscopy (TEM), the apoptosis was determined by Terminal deoxynucleotidyl transferase dUNT nick end labeling (TUNEL) assay, the mRNA expressions of Caspase-3, Caspase-8, Caspase-9, Apaf1, Bcl-2, and Bax were analyzed by RT-PCR, and the protein expressions of Caspase-3 and AIF were assessed by immunofluorescence. This work demonstrated that direct exposure of primary cultured cochlear HCs to ONOO - could result in a base-to-apex gradient injury of HCs in a concentration-dependent manner. Furthermore, ONOO - led to much more losses of outer hair cells than inner hair cells mainly through the induction of apoptosis of HCs as evidenced by TEM and TUNEL assays. The mRNA expressions of Caspase-8, Caspase-9, Apaf1, and Bax were increased and, meanwhile, the mRNA expression of Bcl-2 was decreased in response to ONOO - treatment. Of interesting, the expression of Caspase-3 had no significant change, whereas, the expression alteration of AIF was observed. These results suggested that ONOO - can effectively damage the survival of cochlear HCs via triggering the apoptotic pathway. The findings from this work suggest that ONOO - -induced apoptosis is mediated, at least in part, via a Caspase-independent pathway in cochlear HCs.

  1. Is All Human Hearing Cochlear?

    Directory of Open Access Journals (Sweden)

    Seyede Faranak Emami

    2013-01-01

    Full Text Available The objective of this cross-sectional study was to investigate the possibility that the saccule may contribute to human hearing. The forty participants included twenty healthy people and twenty other subjects selected from patients who presented with benign paroxysmal positional vertigo to Audiology Department of Hazrat Rasoul Akram hospital (Tehran, Iran. Assessments comprised of audiological evaluations, cervical vestibular evoked myogenic potentials (cVEMPs, recognition of spoken phonemes in white noise (Rsp in wn, and auditory brainstem response to 500 Hz tone burst (ABR500 HZ. Twenty affected ears with decreased vestibular excitability as detected by abnormal cVEMPs revealed decreased scores of Rsp in wn and abnormal findings of ABR500 HZ. Both unaffected and normal ears had normal results. Multiple comparisons of mean values of cVEMPs and ABR500 HZ between three groups were significant (P<0.05, ANOVA. The correlation between RSP in wn and p13 latencies was significant. The peak-to-peak amplitudes showed significant correlation to RSP in wn. The correlation between RSP in wn and the latencies of n23 was significant. In high-level of noisy competing situations, healthy human saccular sensation can mediate the detection of low frequencies and possibly help in cochlear hearing for frequency and intensity discrimination. So, all human hearing is not cochlear.

  2. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  3. Management of outer space

    Science.gov (United States)

    Perek, Lubos

    1993-10-01

    Various aspects of space-environment management are discussed. Attention is called to the fact that, while space radio communications are already under an adequate management by the International Communications Union, the use of nuclear power sources is regulated by the recently adopted set of principles, and space debris will be discussed in the near future at the UN COPUOS, other aspects of management of outer space received little or no attention of the international community. These include the competency of crews and technical equipment of spacecraft launched by newcomers to space exploration; monitoring of locations and motions of space objects (now in national hands), with relevant data made accessible through a computer network; and the requirement to use space only for beneficial purposes and not for promoting narrow and debatable interests damaging the outer space environment and impeding on astronomical observations. It is suggested that some of these tasks would be best performed by an international space agency within the UN system of organizations.

  4. Current amplification models of sensorineurall and conductive hearing loss

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2012-01-01

    Full Text Available The main function of a hearing aid is to improve auditory and language abilities of hearing impaired users. The amplification model has to be adapted according to age, degree and type of hearing loss. The goal of this paper is to analyze the current amplification models of sensorineural and conductive hearing loss which can provide a high quality of speech perception and sounds at any degree of hearing loss. The BAHA is a surgically implantable system for treatment of conductive hearing loss that works through direct bone conduction. BAHA is used to help people with chronic ear infections, congenital external auditory canal atresia and single sided deafness who cannot benefit from conventional hearing aids. The last generation of hearing aid for sensorineural hearing loss is cochlear implant. Bimodal amplification improves binaural hearing. Hearing aids alone do not make listening easier in all situations. The things that can interfere with listening are background noises, distance from a sound and reverberation or echo. The device used most often today is the Frequency Modulated (FM system.

  5. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  6. Outer atmospheric research

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1988-01-01

    The region above the earth from about 90 km to 150 km is a major part of the upper or outer atmosphere. It is relatively unexplored, being too high for balloons or aircraft and too low for persistent orbiting spacecraft. However, the concept of a tethered subsatellite, deployed downward from an orbiting, more massive craft such as the Space Shuttle, opens the possibility of a research capability that could provide global mapping of this region. The need for research in this thick spherical shell above the earth falls into two major categories: (1) scientific data for understanding and modeling the global atmosphere and thereby determining its role in the earth system, and (2) engineering data for the design of future aerospace vehicles that will operate there. This paper presents an overview and synthesis of the currently perceived research needs and the state-of-the-art of the proposed tethered research capability. 16 references

  7. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  8. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  9. Music enjoyment with cochlear implantation.

    Science.gov (United States)

    Prevoteau, Charlotte; Chen, Stephanie Y; Lalwani, Anil K

    2018-10-01

    Since the advent of cochlear implant (CI) surgery in the 1960s, there have been remarkable technological and surgical advances enabling excellent speech perception in quiet with many CI users able to use the telephone. However, many CI users struggle with music perception, particularly with the pitch-based and melodic elements of music. Yet remarkably, despite poor music perception, many CI users enjoy listening to music based on self-report questionnaires, and prospective studies have suggested a disassociation between music perception and enjoyment. Music enjoyment is arguably a more functional measure of one's listening experience, and thus enhancing one's listening experience is a worthy goal. Recent studies have shown that re-engineering music to reduce its complexity may enhance enjoyment in CI users and also delineate differences in musical preferences from normal hearing listeners. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. The Human Cochlear Mechanical Nonlinearity Inferred via Psychometric Functions

    Directory of Open Access Journals (Sweden)

    Nizami Lance

    2013-12-01

    Extension of the model of Schairer and colleagues results in credible cochlear nonlinearities in man, suggesting that forward-masking provides a non-invasive way to infer the human mechanical cochlear nonlinearity.

  11. Effects of NSAIDs on the Inner Ear: Possible Involvement in Cochlear Protection

    Directory of Open Access Journals (Sweden)

    Akira Hara

    2010-04-01

    Full Text Available Cyclooxygenase and lipoxygenase, two important enzymes involved in arachidonic acid metabolism, are major targets of non-steroidal anti-inflammatory drugs (NSAIDs. Recent investigations suggest that arachidonic cascades and their metabolites may be involved in maintaining inner ear functions. The excessive use of aspirin may cause tinnitus in humans and impairment of the outer hair cell functions in experimental animals. On the other hand, NSAIDs reportedly exhibit protective effects against various kinds of inner ear disorder. The present review summarizes the effects of NSAIDs on cochlear pathophysiology. NSAIDs are a useful ameliorative adjunct in the management of inner ear disorders.

  12. In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Science.gov (United States)

    2012-01-01

    Background Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI100 cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system. Methods In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode. Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference. Results Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments. Conclusions The recording system implemented in the MED-EL PULSARCI100 cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system. PMID:22531599

  13. Vacuum Outer-Gap Structure in Pulsar Outer Magnetospheres

    International Nuclear Information System (INIS)

    Gui-Fang, Lin; Li, Zhang

    2009-01-01

    We study the vacuum outer-gap structure in the outer magnetosphere of rotation-powered pulsars by considering the limit of trans-field height through a pair production process. In this case, the trans-field height is limited by the photon-photon pair production process and the outer boundary of the outer gap can be extended outside the light cylinder. By solving self-consistently the Poisson equation for electrical potential and the Boltzmann equations of electrons/positrons and γ-rays in a vacuum outer gap for the parameters of Vela pulsar, we obtain an approximate geometry of the outer gap, i.e. the trans-field height is limited by the pair-production process and increases with the radial distance to the star and the width of the outer gap starts at the inner boundary (near the null charge surface) and ends at the outer boundary which locates inside or outside the light cylinder depending on the inclination angle. (geophysics, astronomy, and astrophysics)

  14. Energy Flux in the Cochlea: Evidence Against Power Amplification of the Traveling Wave.

    Science.gov (United States)

    van der Heijden, Marcel; Versteegh, Corstiaen P C

    2015-10-01

    Traveling waves in the inner ear exhibit an amplitude peak that shifts with frequency. The peaking is commonly believed to rely on motile processes that amplify the wave by inserting energy. We recorded the vibrations at adjacent positions on the basilar membrane in sensitive gerbil cochleae and tested the putative power amplification in two ways. First, we determined the energy flux of the traveling wave at its peak and compared it to the acoustic power entering the ear, thereby obtaining the net cochlear power gain. For soft sounds, the energy flux at the peak was 1 ± 0.6 dB less than the middle ear input power. For more intense sounds, increasingly smaller fractions of the acoustic power actually reached the peak region. Thus, we found no net power amplification of soft sounds and a strong net attenuation of intense sounds. Second, we analyzed local wave propagation on the basilar membrane. We found that the waves slowed down abruptly when approaching their peak, causing an energy densification that quantitatively matched the amplitude peaking, similar to the growth of sea waves approaching the beach. Thus, we found no local power amplification of soft sounds and strong local attenuation of intense sounds. The most parsimonious interpretation of these findings is that cochlear sensitivity is not realized by amplifying acoustic energy, but by spatially focusing it, and that dynamic compression is realized by adjusting the amount of dissipation to sound intensity.

  15. Low-frequency sound exposure causes reversible long-term changes of cochlear transfer characteristics.

    Science.gov (United States)

    Drexl, Markus; Otto, Larissa; Wiegrebe, Lutz; Marquardt, Torsten; Gürkov, Robert; Krause, Eike

    2016-02-01

    Intense, low-frequency sound presented to the mammalian cochlea induces temporary changes of cochlear sensitivity, for which the term 'Bounce' phenomenon has been coined. Typical manifestations are slow oscillations of hearing thresholds or the level of otoacoustic emissions. It has been suggested that these alterations are caused by changes of the mechano-electrical transducer transfer function of outer hair cells (OHCs). Shape estimates of this transfer function can be derived from low-frequency-biased distortion product otoacoustic emissions (DPOAE). Here, we tracked the transfer function estimates before and after triggering a cochlear Bounce. Specifically, cubic DPOAEs, modulated by a low-frequency biasing tone, were followed over time before and after induction of the cochlear Bounce. Most subjects showed slow, biphasic changes of the transfer function estimates after low-frequency sound exposure relative to the preceding control period. Our data show that the operating point changes biphasically on the transfer function with an initial shift away from the inflection point followed by a shift towards the inflection point before returning to baseline values. Changes in transfer function and operating point lasted for about 180 s. Our results are consistent with the hypothesis that intense, low-frequency sound disturbs regulatory mechanisms in OHCs. The homeostatic readjustment of these mechanisms after low-frequency offset is reflected in slow oscillations of the estimated transfer functions. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. The effect of BAPTA and 4AP in scala media on transduction and cochlear gain.

    Science.gov (United States)

    Sellick, P M; Robertson, D; Patuzzi, R

    2006-01-01

    We have injected by iontophoresis 4-amino-pyridine, a K+ channel blocker and BAPTA, (a Ca++ chelator), into scala media of the first three turns of the guinea pig cochlea. We measured the reduction in outer hair cell (OHC) receptor current, as indicated by cochlear microphonic measured in scala media evoked by a 207 Hz tone, and compared this with the elevation of the cochlear action potential (CAP) threshold. We found that in the basal turn, for frequencies between 12 and 21 kHz, CAP threshold was elevated by about 30 dB, while in the second turn, at the 3 kHz place, the maximum elevation was 15 dB. In the third turn, iontophoresis of 4AP and BAPTA reduced CM by similar amounts to that in the basal and second turn, but caused negligible elevation of CAP threshold. We conclude that the gain of the cochlear amplifier is maximal for basal turn frequencies, is halved at 3 kHz, and is reduced to close to one for frequencies below 1 kHz (no active gain). The effect of 4AP and BAPTA on neural threshold and the receptor current represented by CM may be explained by their action on OHC transduction without the involvement of IHCs.

  17. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  18. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  19. Evidence of high-elevation amplification versus Arctic amplification.

    Science.gov (United States)

    Wang, Qixiang; Fan, Xiaohui; Wang, Mengben

    2016-01-12

    Elevation-dependent warming in high-elevation regions and Arctic amplification are of tremendous interest to many scientists who are engaged in studies in climate change. Here, using annual mean temperatures from 2781 global stations for the 1961-2010 period, we find that the warming for the world's high-elevation stations (>500 m above sea level) is clearly stronger than their low-elevation counterparts; and the high-elevation amplification consists of not only an altitudinal amplification but also a latitudinal amplification. The warming for the high-elevation stations is linearly proportional to the temperature lapse rates along altitudinal and latitudinal gradients, as a result of the functional shape of Stefan-Boltzmann law in both vertical and latitudinal directions. In contrast, neither altitudinal amplification nor latitudinal amplification is found within the Arctic region despite its greater warming than lower latitudes. Further analysis shows that the Arctic amplification is an integrated part of the latitudinal amplification trend for the low-elevation stations (≤500 m above sea level) across the entire low- to high-latitude Northern Hemisphere, also a result of the mathematical shape of Stefan-Boltzmann law but only in latitudinal direction.

  20. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  1. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  2. The group delay and suppression pattern of the cochlear microphonic potential recorded at the round window.

    Directory of Open Access Journals (Sweden)

    Wenxuan He

    Full Text Available BACKGROUND: It is commonly assumed that the cochlear microphonic potential (CM recorded from the round window (RW is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. METHODOLOGY/PRINCIPAL FINDINGS: This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. CONCLUSIONS/SIGNIFICANCE: We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases.

  3. Effects of piracetam supplementation on cochlear damage occuring in guinea pigs exposed to irradiation

    International Nuclear Information System (INIS)

    Altas, E.; Ertekin, M.V.; Kuduban, O.; Gundogdu, C.; Demirci, E.; Sutbeyaz, Y.

    2006-01-01

    In this study we aimed to determine the role of piracetam (PIR) in preventing radiation induced cochlear damage after total-cranium irradiation (radiotherapy; RT). Male albino guinea pigs used in the study were randomly divided into three groups. Group 1 (Control group) (n=11) received neither PIR nor irradiation, but received saline solution intraperitoneally (i.p.) and received sham irradiation. Group 2 (RT group) (n=32) was exposed to total cranium irradiation of 33 Gy in 5 fractions of 6.6 Gy/d for five successive days, with a calculated (α/β=3.5) biological effective dose of fractionated irradiation equal to 60 Gy conventional fractionation, then received saline solution for five successive days i.p. Group 3 (PIR+RT group) (n=33) received total cranium irradiation, plus 350 mg/kg per day PIR for five successive days i.p. After the last dose of RT, the guinea pigs were all sacrificed at the 4th, 24th and 96th hours, respectively. Their cochleas were enucleated for histopathologic examination. It was observed that total cranium irradiation (RT group) promoted degeneration in stria vascularis (SV), spiral ganglion cells (SG), outer hair cells (OHC) and inner hair cell (IHC) of cochleas at these times (p 0.05) and IHC at 4th, 24th hours (p>0.05), there was a significant difference on radiation-induced cochlear degeneration in SV and OHC at 24th and 96th hours (p<0.05), IHC at 96th hour (p<0.05) and SG at 4th, 24th and 96th hours (p<0.05). There was no any cochlear degeneration in the control group. Piracetam might reduce radiation-induced cochlear damage in the guinea pig. These results are pioneer to studies that will be performed with PIR for radiation toxicity protection. (author)

  4. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  5. Efficient Audio Power Amplification - Challenges

    DEFF Research Database (Denmark)

    Andersen, Michael Andreas E.

    2005-01-01

    For more than a decade efficient audio power amplification has evolved and today switch-mode audio power amplification in various forms are the state-of-the-art. The technical steps that lead to this evolution are described and in addition many of the challenges still to be faced and where...

  6. Efficient audio power amplification - challenges

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Michael A.E.

    2005-07-01

    For more than a decade efficient audio power amplification has evolved and today switch-mode audio power amplification in various forms are the state-of-the-art. The technical steps that lead to this evolution are described and in addition many of the challenges still to be faced and where extensive research and development are needed is covered. (au)

  7. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  8. Music Therapy for Preschool Cochlear Implant Recipients

    Science.gov (United States)

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  9. Turbine airfoil with outer wall thickness indicators

    Science.gov (United States)

    Marra, John J; James, Allister W; Merrill, Gary B

    2013-08-06

    A turbine airfoil usable in a turbine engine and including a depth indicator for determining outer wall blade thickness. The airfoil may include an outer wall having a plurality of grooves in the outer surface of the outer wall. The grooves may have a depth that represents a desired outer surface and wall thickness of the outer wall. The material forming an outer surface of the outer wall may be removed to be flush with an innermost point in each groove, thereby reducing the wall thickness and increasing efficiency. The plurality of grooves may be positioned in a radially outer region of the airfoil proximate to the tip.

  10. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  11. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  12. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  13. Environmental Sound Training in Cochlear Implant Users

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  14. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  15. Gender Categorization in Cochlear Implant Users

    Science.gov (United States)

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  16. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  17. Listening Effort With Cochlear Implant Simulations

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; Başkent, Deniz

    2013-01-01

    Purpose: Fitting a cochlear implant (CI) for optimal speech perception does not necessarily optimize listening effort. This study aimed to show that listening effort may change between CI processing conditions for which speech intelligibility remains constant. Method: Nineteen normal-hearing

  18. DNAzyme Feedback Amplification: Relaying Molecular Recognition to Exponential DNA Amplification.

    Science.gov (United States)

    Liu, Meng; Yin, Qingxin; McConnell, Erin M; Chang, Yangyang; Brennan, John D; Li, Yingfu

    2018-03-26

    Technologies capable of linking DNA amplification to molecular recognition are very desirable for ultrasensitive biosensing applications. We have developed a simple but powerful isothermal DNA amplification method, termed DNAzyme feedback amplification (DFA), that is capable of relaying molecular recognition to exponential DNA amplification. The method incorporates both an RNA-cleaving DNAzyme (RCD) and rolling circle amplification (RCA) carried out by a special DNA polymerase using a circular DNA template. DFA begins with a stimulus-dependent RCA reaction, producing tandemly linked RCDs in long-chain DNA products. These RCDs cleave an RNA-containing DNA sequence to form additional primers that hybridize to the circular DNA molecule, giving rise to DNA assemblies that act as the new inputs for RCA. The RCA reaction and the cleavage event keep on feeding each other autonomously, resulting in exponential growth of repetitive DNA sequences that can be easily detected. This method can be used for the detection of both nucleic acid based targets and non-nucleic acid analytes. In this article, we discuss the conceptual framework of the feedback amplification approach, the essential features of this method as well as remaining challenges and possible solutions. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Efficient estimates of cochlear hearing loss parameters in individual listeners

    DEFF Research Database (Denmark)

    Fereczkowski, Michal; Jepsen, Morten Løve; Dau, Torsten

    2013-01-01

    It has been suggested that the level corresponding to the knee-point of the basilar membrane (BM) input/output (I/O) function can be used to estimate the amount of inner- and outer hair-cell loss (IHL, OHL) in listeners with a moderate cochlear hearing impairment Plack et al. (2004). According...... to Jepsen and Dau (2011) IHL + OHL = HLT [dB], where HLT stands for total hearing loss. Hence having estimates of the total hearing loss and OHC loss, one can estimate the IHL. In the present study, results from forward masking experiments based on temporal masking curves (TMC; Nelson et al., 2001...... estimates of the knee-point level. Further, it is explored whether it is possible to estimate the compression ratio using only on-frequency TMCs. 10 normal-hearing and 10 hearing-impaired listeners (with mild-to-moderate sensorineural hearing loss) were tested at 1, 2 and 4 kHz. The results showed...

  20. Anomalous facial nerve canal with cochlear malformations.

    Science.gov (United States)

    Romo, L V; Curtin, H D

    2001-05-01

    Anteromedial "migration" of the first segment of the facial nerve canal has been previously identified in a patient with a non-Mondini-type cochlear malformation. In this study, several patients with the same facial nerve canal anomaly were reviewed to assess for the association and type of cochlear malformation. CT scans of the temporal bone of 15 patients with anteromedial migration of the first segment of the facial nerve canal were collected from routine departmental examinations. In seven patients, the anomalous course was bilateral, for a total of 22 cases. The migration was graded relative to normal as either mild/moderate or pronounced. The cochlea in each of these cases was examined for the presence and size of the basilar, second, and apical turns. The turns were either absent, small, normal, or enlarged. The CT scans of five patients with eight Mondini malformations were examined for comparison. The degree of the facial nerve migration was pronounced in nine cases and mild/moderate in 13. All 22 of these cases had associated cochlear abnormalities of the non-Mondini variety. These included common cavity anomalies with lack of definition between the cochlea and vestibule (five cases), cochleae with enlarged basilar turns and absent second or third turns (five cases), and cochleae with small or normal basilar turns with small or absent second or third turns (12 cases). None of the patients with Mondini-type cochlear malformations had anteromedial migration of the facial nerve canal. Anteromedial migration of the facial nerve canal occurs in association with some cochlear malformations. It did not occur in association with the Mondini malformations. A cochlea with a Mondini malformation, being similar in size to a normal cochlea, may physically prohibit such a deviation in course.

  1. Next generation Chirped Pulse Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nees, J; Biswal, S; Mourou, G [Univ. Michigan, Center for Ultrafast Optical Science, Ann Arbor, MI (United States); Nishimura, Akihiko; Takuma, Hiroshi

    1998-03-01

    The limiting factors of Chirped Pulse Amplification (CPA) are discussed and experimental results of CPA in Yb:glass regenerative amplifier are given. Scaling of Yb:glass to the petawatt level is briefly discussed. (author)

  2. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  3. Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of fasciolosis in sheep and its application under field conditions

    OpenAIRE

    Mart?nez-Valladares, Mar?a; Rojo-V?zquez, Francisco Antonio

    2016-01-01

    Background Loop-mediated isothermal amplification (LAMP) is a very specific, efficient, and rapid gene amplification procedure in which the reaction can run at a constant temperature. In the current study we have developed a LAMP assay to improve the diagnosis of Fasciola spp. in the faeces of sheep. Findings After the optimisation of the LAMP assay we have shown similar results between this technique and the standard PCR using the outer primers of the LAMP reaction. In both cases the limit o...

  4. Progression of changes in the sensorial elements of the cochlear and peripheral vestibular systems: The otitis media continuum.

    Science.gov (United States)

    Monsanto, Rafael da Costa; Schachern, Patricia; Paparella, Michael M; Cureoglu, Sebahattin; Penido, Norma de Oliveira

    2017-08-01

    Our study aimed to evaluate pathologic changes in the cochlear (inner and outer hair cells and stria vascularis) and vestibular (vestibular hair cells, dark, and transitional cells) sensorial elements in temporal bones from donors who had otitis media. We studied 40 temporal bones from such donors, which were categorized in serous otitis media (SOM), serous-purulent otitis media (SPOM), mucoid/mucoid-purulent otitis media (MOM/MPOM), and chronic otitis media (COM); control group comprised 10 nondiseased temporal bones. We found significant loss of inner and outer cochlear hair cells in the basal turn of the SPOM, MOM/MPOM and COM groups; significant loss of vestibular hair cells was observed in the MOM/MPOM and COM groups. All otitis media groups had smaller mean area of the stria vascularis in the basal turn of the cochlea when compared to controls. In conclusion, our study demonstrated more severe pathologic changes in the later stages of the continuum of otitis media (MOM/MPOM and COM). Those changes seem to progress from the basal turn of the cochlea (stria vascularis, then inner and outer hair cells) to the middle turn of the cochlea and to the saccule and utricle in the MOM/MPOM and COM stages. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  6. The CMS Outer Hadron Calorimeter

    CERN Document Server

    Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Bawa, Harinder Singh; Beri, Suman Bala; Bhandari, Virender; Bhatnagar, Vipin; Chendvankar, Sanjay; Deshpande, Pandurang Vishnu; Dugad, Shashikant; Ganguli, Som N; Guchait, Monoranjan; Gurtu, Atul; Kalmani, Suresh Devendrappa; Kaur, Manjit; Kohli, Jatinder Mohan; Krishnaswamy, Marthi Ramaswamy; Kumar, Arun; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Narasimham, Vemuri Syamala; Patil, Mandakini Ravindra; Reddy, L V; Satyanarayana, B; Sharma, Seema; Singh, B; Singh, Jas Bir; Sudhakar, Katta; Tonwar, Suresh C; Verma, Piyush

    2006-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with a outer calorimeter to ensure high energy shower containment in CMS and thus working as a tail catcher. Fabrication, testing and calibrations of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter has a very good signal to background ratio even for a minimum ionising particle and can hence be used in coincidence with the Resistive Plate Chambers of the CMS detector for the muon trigger.

  7. Origin of Outer Solar System

    Science.gov (United States)

    Holman, Matthew J.; Lindstrom, David (Technical Monitor)

    2005-01-01

    Our ongoing research program combines extensive deep and wide-field observations using a variety of observational platforms with numerical studies of the dynamics of small bodies in the outer solar system in order to advance the main scientific goals of the community studying the Kuiper belt and the outer solar system. These include: (1) determining the relative populations of the known classes of KBOs as well as other possible classes; ( 2 ) determining the size distributions or luminosity function of the individual populations or the Kuiper belt as a whole; (3) determining the inclinations distributions of these populations; (4) establishing the radial extent of the Kuiper belt; ( 5 ) measuring and relating the physical properties of different types of KBOs to those of other solar system bodies; and, (6) completing our systematic inventory of the satellites of the outer planets.

  8. Nuclear fuel grid outer strap

    International Nuclear Information System (INIS)

    Duncan, R.; Craver, J.E.

    1989-01-01

    This patent describes a nuclear reactor fuel assembly grid. It comprises a first outer grip strap segment end. The first end having a first tab arranged in substantially the same plane as the plane defined by the first end; a second outer grip strap end. The second end having a second slot arranged in substantially the same plane as the plane defined by the second end, with the tab being substantially disposed in the slot, defining a socket therebetween; and a fort tine interposed substantially perpendicularly in the socket

  9. [The development of musicality in children after cochlear implantation].

    Science.gov (United States)

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (Pmusicality also showed significant improvements with time for control group (P0.05). Significant difference was noted between the two groups at 24 months (Pmusicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  10. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  11. Getting Sloshed in Outer Space

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 12. Getting Sloshed in Outer Space - Liquid Behavior in Microgravity. N Ananthkrishnan. General Article Volume 12 Issue 12 December 2007 pp 40-45. Fulltext. Click here to view fulltext PDF. Permanent link:

  12. Outer space structure and development

    International Nuclear Information System (INIS)

    Zeldovich, J.; Novikov, I.

    1975-01-01

    A brief account is presented answering the question of what in fact the outer space we observe consists of. The principle of spatial homogeneity of the universe and the idea of non-stationary cosmology are discussed. The origin and the future development of the universe are explained using the two above mentioned and some other hypotheses. (J.K.)

  13. Outer space structure and development

    Energy Technology Data Exchange (ETDEWEB)

    Zeldovich, J; Novikov, I

    1975-10-01

    A brief account is presented answering the question of what in fact the outer space we observe consists of. The principle of spatial homogeneity of the universe and the idea of non-stationary cosmology are discussed. The origin and the future development of the universe are explained using the two above mentioned and some other hypotheses.

  14. Plasmas in the outer heliosphere

    Science.gov (United States)

    Belcher, J. W.; Richardson, J. D.; Lazarus, A. J.; Gazis, P. R.; Barnes, A.

    1995-01-01

    We review the observed properties of the solar wind in the outer heliosphere, including observations from Voyager and the Pioneers, as well as from inner heliospheric probes as appropriate. These observations are crucial to modeling of the heliosphere and its interactions with the interstellar medium, since the wind ram pressure and its temporal variations are important in understanding the distance to the termination shock and heliopause and how those boundaries might vary in time. We focus on results since Solar Wind 7. Among the issues we will discuss are: (1) the time scales for and statistical properties of variations in the ram pressure in the outer heliosphere, and how those variations might affect the morphology of the heliospheric/interstellar medium interface; (2) the question of possible solar wind slowing in the outer heliosphere due to the pick-up of interstellar ions; (3) the issue of whether there is bulk heating of the solar wind associated either with interstellar ion pick-up or with continued heating due to stream-stream interactions; (4) evidence for latitudinal variations in solar wind properties; and (5) the 1.3 year periodicities apparent in the outer heliosphere, and the close correspondence with similar variations seen with inner heliospheric probes.

  15. Outer Synchronization of Complex Networks by Impulse

    International Nuclear Information System (INIS)

    Sun Wen; Yan Zizong; Chen Shihua; Lü Jinhu

    2011-01-01

    This paper investigates outer synchronization of complex networks, especially, outer complete synchronization and outer anti-synchronization between the driving network and the response network. Employing the impulsive control method which is uncontinuous, simple, efficient, low-cost and easy to implement in practical applications, we obtain some sufficient conditions of outer complete synchronization and outer anti-synchronization between two complex networks. Numerical simulations demonstrate the effectiveness of the proposed impulsive control scheme. (general)

  16. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  17. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  18. Prevention of Noise Damage to Cochlear Synapses

    Science.gov (United States)

    2017-10-01

    Assessment of synapse regeneration : Twelve week old CBA/CaJ mice are exposed to a moderate noise that destroys synapses on inner hair cells (IHCs) but spares...result of excitotoxic trauma to cochlear synapses due to glutamate released from the hair cells . Excitotoxic trauma damages the postsynaptic cell by...components ............................................. 12 d) Quantitative analysis of effects of neurotrophic factors on synapse regeneration in vitro

  19. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  20. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  1. Cochlear pathology in chronic suppurative otitis media.

    Science.gov (United States)

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  2. Medial olivocochlear reflex interneurons are located in the posteroventral cochlear nucleus: a kainic acid lesion study in guinea pigs.

    Science.gov (United States)

    de Venecia, Ronald K; Liberman, M Charles; Guinan, John J; Brown, M Christian

    2005-07-11

    The medial olivocochlear (MOC) reflex arc is probably a three-neuron pathway consisting of type I spiral ganglion neurons, reflex interneurons in the cochlear nucleus, and MOC neurons that project to the outer hair cells of the cochlea. We investigated the identity of MOC reflex interneurons in the cochlear nucleus by assaying their regional distribution using focal injections of kainic acid. Our reflex metric was the amount of change in the distortion product otoacoustic emission (at 2f(1)-f(2)) just after onset of the primary tones. This metric for MOC reflex strength has been shown to depend on an intact reflex pathway. Lesions involving the posteroventral cochlear nucleus (PVCN), but not the other subdivisions, produced long-term decreases in MOC reflex strength. The degree of cell loss within the dorsal part of the PVCN was a predictor of whether the lesion affected MOC reflex strength. We suggest that multipolar cells within the PVCN have the distribution and response characteristics appropriate to be the MOC reflex interneurons. (c) 2005 Wiley-Liss, Inc.

  3. Turbine airfoil with a compliant outer wall

    Science.gov (United States)

    Campbell, Christian X [Oviedo, FL; Morrison, Jay A [Oviedo, FL

    2012-04-03

    A turbine airfoil usable in a turbine engine with a cooling system and a compliant dual wall configuration configured to enable thermal expansion between inner and outer layers while eliminating stress formation in the outer layer is disclosed. The compliant dual wall configuration may be formed a dual wall formed from inner and outer layers separated by a support structure. The outer layer may be a compliant layer configured such that the outer layer may thermally expand and thereby reduce the stress within the outer layer. The outer layer may be formed from a nonplanar surface configured to thermally expand. In another embodiment, the outer layer may be planar and include a plurality of slots enabling unrestricted thermal expansion in a direction aligned with the outer layer.

  4. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    Background. Cochlear implantation aims to provide an effective means of spoken communication for prelingually deaf children. However, studies in this field are mostly clinically orientated, with little focus on the experiences and long-term concerns of families post cochlear implantation (CI). Objective. To describe the ...

  5. Emotion Understanding in Deaf Children with a Cochlear Implant

    Science.gov (United States)

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  6. Remote programming of cochlear implants: a telecommunications model.

    Science.gov (United States)

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  7. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  8. Verbal Working Memory in Children with Cochlear Implants

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  9. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  10. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    Science.gov (United States)

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  11. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  12. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  13. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  14. Paraquat initially damages cochlear support cells leading to anoikis-like hair cell death.

    Science.gov (United States)

    Zhang, Jianhui; Sun, Hong; Salvi, Richard; Ding, Dalian

    2018-07-01

    Paraquat (PQ), one of the most widely used herbicides, is extremely dangerous because it generates the highly toxic superoxide radical. When paraquat was applied to cochlear organotypic cultures, it not only damaged the outer hair cells (OHCs) and inner hair cells (IHCs), but also caused dislocation of the hair cell rows. We hypothesized that the dislocation arose from damage to the support cells (SCs) that anchors hair cells within the epithelium. To test this hypothesis, rat postnatal cochlear cultures were treated with PQ. Shortly after PQ treatment, the rows of OHCs separated from one another and migrated radially away from IHCs suggesting loss of cell-cell adhesion that hold the hair cells in proper alignment. Hair cells dislocation was associated with extensive loss of SCs in the organ of Corti, loss of tympanic border cells (TBCs) beneath the basilar membrane, the early appearance of superoxide staining and caspase-8 labeling in SCs below the OHCs and disintegration of E-cadherin and β-catenin in the organ of Corti. Damage to the TBCs and SCs occurred prior to loss of OHC or IHC loss suggesting a form of detachment-induced apoptosis referred to as anoikis. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Genome position and gene amplification

    Czech Academy of Sciences Publication Activity Database

    Jirsová, Pavla; Snijders, A.M.; Kwek, S.; Roydasgupta, R.; Fridlyand, J.; Tokuyasu, T.; Pinkel, D.; Albertson, D. G.

    2007-01-01

    Roč. 8, č. 6 (2007), r120 ISSN 1474-760X Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : gene amplification * array comparative genomic hybridization * oncogene Subject RIV: BO - Biophysics Impact factor: 6.589, year: 2007

  16. Facial nerve stimulation outcomes after cochlear implantation with cochlear-facial dehiscence

    Directory of Open Access Journals (Sweden)

    Christina H. Fang, MD

    2017-06-01

    Conclusion: Cochlear-facial dehiscence can predispose patients to post-implant FNS. Prior temporal bone irradiation may carry a higher risk of FNS. We recommend scrutiny for CFD in CTs of CI candidates and appropriate risk counseling for FNS if CFD is discovered and more frequent monitoring for FNS by audiology.

  17. Mitochondrial dysfunction underlying outer retinal diseases

    DEFF Research Database (Denmark)

    Lefevere, Evy; Toft-Kehler, Anne Katrine; Vohra, Rupali

    2017-01-01

    Dysfunction of photoreceptors, retinal pigment epithelium (RPE) or both contribute to the initiation and progression of several outer retinal disorders. Disrupted Müller glia function might additionally subsidize to these diseases. Mitochondrial malfunctioning is importantly associated with outer...

  18. Miniaturized isothermal nucleic acid amplification, a review.

    Science.gov (United States)

    Asiello, Peter J; Baeumner, Antje J

    2011-04-21

    Micro-Total Analysis Systems (µTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.

  19. WORKSHOP: Inner space - outer space

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    During the first week of May, the Fermilab theoretical astrophysics group hosted an international conference on science at the interface of particle physics and cosmology/astrophysics. The conference (Inner Space-Outer Space) was attended by a very diverse group of more than 200 physical scientists, including astronomers, astrophysicists, cosmologists, low-temperature physicists, and elementary particle theorists and experimentalists. The common interest which brought this diverse group to gether is the connection between physics on the smallest scale probed by man - the realm of elementary particle physics - and physics on the largest scale imaginable (the entire Universe) - the realm of cosmology

  20. WORKSHOP: Inner space - outer space

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-09-15

    During the first week of May, the Fermilab theoretical astrophysics group hosted an international conference on science at the interface of particle physics and cosmology/astrophysics. The conference (Inner Space-Outer Space) was attended by a very diverse group of more than 200 physical scientists, including astronomers, astrophysicists, cosmologists, low-temperature physicists, and elementary particle theorists and experimentalists. The common interest which brought this diverse group to gether is the connection between physics on the smallest scale probed by man - the realm of elementary particle physics - and physics on the largest scale imaginable (the entire Universe) - the realm of cosmology.

  1. Outer scale of atmospheric turbulence

    Science.gov (United States)

    Lukin, Vladimir P.

    2005-10-01

    In the early 70's, the scientists in Italy (A.Consortini, M.Bertolotti, L.Ronchi), USA (R.Buser, Ochs, S.Clifford) and USSR (V.Pokasov, V.Lukin) almost simultaneously discovered the phenomenon of deviation from the power law and the effect of saturation for the structure phase function. During a period of 35 years we have performed successively the investigations of the effect of low-frequency spectral range of atmospheric turbulence on the optical characteristics. The influence of the turbulence models as well as a outer scale of turbulence on the characteristics of telescopes and systems of laser beam formations has been determined too.

  2. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  3. Racemic alkaloids from the fungus Ganoderma cochlear.

    Science.gov (United States)

    Wang, Xin-Long; Dou, Man; Luo, Qi; Cheng, Li-Zhi; Yan, Yong-Ming; Li, Rong-Tao; Cheng, Yong-Xian

    2017-01-01

    Seven pairs of new alkaloid enantiomers, ganocochlearines C-I (1, 3-8), and three pairs of known alkaloids were isolated from the fruiting bodies of Ganoderma cochlear. The chemical structures of new compounds were elucidated on the basis of 1D and 2D NMR data. The absolute configurations of compounds 1, 3-10 were assigned by ECD calculations. Biological activities of these isolates against renal fibrosis were accessed in rat normal or diseased renal interstitial fibroblast cells. Importantly, the plausible biosynthetic pathway for this class of alkaloids was originally proposed. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  5. Coherent correlation enhancement of outer shell photoionization cross sections of alkali-like ions

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Avdonina, B.; Pratt, R.H.

    1995-01-01

    An alkali-like ion interaction with inner electrons of an alkali-like ion leads to a significant increase in the photoionization cross section of the outer s electron. This occurs not only for ground-state ions with one s electron in the outer shell, but also when the outer s electron is in an excited state. The reason for this amplification, in addition to coherent enhancement in summing of the correlation amplitudes, is that the zero in the direct amplitude occurs below threshold. This leads to a constructive interference with the correlation amplitude above the photoionization threshold, in contrast to a destructive interference in the case of a neutral atom with the same electronic configuration, for which the zero occurs above threshold. Results of this research were published

  6. Laser amplification in excited dielectrics

    Science.gov (United States)

    Winkler, Thomas; Haahr-Lillevang, Lasse; Sarpe, Cristian; Zielinski, Bastian; Götte, Nadine; Senftleben, Arne; Balling, Peter; Baumert, Thomas

    2018-01-01

    Wide-bandgap dielectrics such as glasses or water are transparent at visible and infrared wavelengths. This changes when they are exposed to ultrashort and highly intense laser pulses. Different interaction mechanisms lead to the appearance of various transient nonlinear optical phenomena. Using these, the optical properties of dielectrics can be controlled from the transparent to the metal-like state. Here we expand this range by a yet unexplored mechanism in excited dielectrics: amplification. In a two-colour pump-probe experiment, we show that a 400 nm femtosecond laser pulse is coherently amplified inside an excited sapphire sample on a scale of a few micrometres. Simulations strongly support the proposed two-photon stimulated emission process, which is temporally and spatially controllable. Consequently, we expect applications in all fields that demand strongly localized amplification.

  7. Measuring the amplification of attention

    OpenAIRE

    Blaser, Erik; Sperling, George; Lu, Zhong-Lin

    1999-01-01

    An ambiguous motion paradigm, in which the direction of apparent motion is determined by salience (i.e., the extent to which an area is perceived as figure versus ground), is used to assay the amplification of color by attention to color. In the red–green colored gratings used in these experiments, without attention instructions, salience depends on the chromaticity difference between colored stripes embedded in the motion sequence and the yellow background. Selective attention to red (or to ...

  8. Spheromak Impedance and Current Amplification

    International Nuclear Information System (INIS)

    Fowler, T K; Hua, D D; Stallard, B W

    2002-01-01

    It is shown that high current amplification can be achieved only by injecting helicity on the timescale for reconnection, τ REC , which determines the effective impedance of the spheromak. An approximate equation for current amplification is: dI TOR 2 /dt ∼ I 2 /τ REC - I TOR 2 /τ closed where I is the gun current, I TOR is the spheromak toroidal current and τ CLOSED is the ohmic decay time of the spheromak. Achieving high current amplification, I TOR >> I, requires τ REC CLOSED . For resistive reconnection, this requires reconnection in a cold zone feeding helicity into a hot zone. Here we propose an impedance model based on these ideas in a form that can be implemented in the Corsica-based helicity transport code. The most important feature of the model is the possibility that τ REC actually increases as the spheromak temperature increases, perhaps accounting for the ''voltage sag'' observed in some experiments, and a tendency toward a constant ratio of field to current, B ∝ I, or I TOR ∼ I. Program implications are discussed

  9. Deletion of PDZD7 disrupts the Usher syndrome type 2 protein complex in cochlear hair cells and causes hearing loss in mice.

    Science.gov (United States)

    Zou, Junhuang; Zheng, Tihua; Ren, Chongyu; Askew, Charles; Liu, Xiao-Ping; Pan, Bifeng; Holt, Jeffrey R; Wang, Yong; Yang, Jun

    2014-05-01

    Usher syndrome type 2 (USH2) is the predominant form of USH, a leading genetic cause of combined deafness and blindness. PDZD7, a paralog of two USH causative genes, USH1C and USH2D (WHRN), was recently reported to be implicated in USH2 and non-syndromic deafness. It encodes a protein with multiple PDZ domains. To understand the biological function of PDZD7 and the pathogenic mechanism caused by PDZD7 mutations, we generated and thoroughly characterized a Pdzd7 knockout mouse model. The Pdzd7 knockout mice exhibit congenital profound deafness, as assessed by auditory brainstem response, distortion product otoacoustic emission and cochlear microphonics tests, and normal vestibular function, as assessed by their behaviors. Lack of PDZD7 leads to the disorganization of stereocilia bundles and a reduction in mechanotransduction currents and sensitivity in cochlear outer hair cells. At the molecular level, PDZD7 determines the localization of the USH2 protein complex, composed of USH2A, GPR98 and WHRN, to ankle links in developing cochlear hair cells, likely through its direct interactions with these three proteins. The localization of PDZD7 to the ankle links of cochlear hair bundles also relies on USH2 proteins. In photoreceptors of Pdzd7 knockout mice, the three USH2 proteins largely remain unchanged at the periciliary membrane complex. The electroretinogram responses of both rod and cone photoreceptors are normal in knockout mice at 1 month of age. Therefore, although the organization of the USH2 complex appears different in photoreceptors, it is clear that PDZD7 plays an essential role in organizing the USH2 complex at ankle links in developing cochlear hair cells. GenBank accession numbers: KF041446, KF041447, KF041448, KF041449, KF041450, KF041451.

  10. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  11. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  12. Conditional deletion of pejvakin in adult outer hair cells causes progressive hearing loss in mice.

    Science.gov (United States)

    Harris, Suzan L; Kazmierczak, Marcin; Pangršič, Tina; Shah, Prahar; Chuchvara, Nadiya; Barrantes-Freer, Alonso; Moser, Tobias; Schwander, Martin

    2017-03-06

    Mutations in the Pejvakin (Pjvk) gene cause autosomal recessive hearing loss DFNB59 with audiological features of auditory neuropathy spectrum disorder (ANSD) or cochlear dysfunction. The precise mechanisms underlying the variable clinical phenotypes of DFNB59 remain unclear. Here, we demonstrate that mice with conditional ablation of the Pjvk gene in all sensory hair cells or only in outer hair cells (OHCs) show similar auditory phenotypes with early-onset profound hearing loss. By contrast, loss of Pjvk in adult OHCs causes a slowly progressive hearing loss associated with OHC degeneration and delayed loss of inner hair cells (IHCs), indicating a primary role for pejvakin in regulating OHC function and survival. Consistent with this model, synaptic transmission at the IHC ribbon synapse is largely unaffected in sirtaki mice that carry a C-terminal deletion mutation in Pjvk. Using the C-terminal domain of pejvakin as bait, we identified in a cochlear cDNA library ROCK2, an effector for the small GTPase Rho, and the scaffold protein IQGAP1, involved in modulating actin dynamics. Both ROCK2 and IQGAP1 associate via their coiled-coil domains with pejvakin. We conclude that pejvakin is required to sustain OHC activity and survival in a cell-autonomous manner likely involving regulation of Rho signaling. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  13. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    Science.gov (United States)

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Reciprocal synapses between outer hair cells and their afferent terminals: evidence for a local neural network in the mammalian cochlea.

    Science.gov (United States)

    Thiers, Fabio A; Nadol, Joseph B; Liberman, M Charles

    2008-12-01

    Cochlear outer hair cells (OHCs) serve both as sensory receptors and biological motors. Their sensory function is poorly understood because their afferent innervation, the type-II spiral ganglion cell, has small unmyelinated axons and constitutes only 5% of the cochlear nerve. Reciprocal synapses between OHCs and their type-II terminals, consisting of paired afferent and efferent specialization, have been described in the primate cochlea. Here, we use serial and semi-serial-section transmission electron microscopy to quantify the nature and number of synaptic interactions in the OHC area of adult cats. Reciprocal synapses were found in all OHC rows and all cochlear frequency regions. They were more common among third-row OHCs and in the apical half of the cochlea, where 86% of synapses were reciprocal. The relative frequency of reciprocal synapses was unchanged following surgical transection of the olivocochlear bundle in one cat, confirming that reciprocal synapses were not formed by efferent fibers. In the normal ear, axo-dendritic synapses between olivocochlear terminals and type-II terminals and/or dendrites were as common as synapses between olivocochlear terminals and OHCs, especially in the first row, where, on average, almost 30 such synapses were seen in the region under a single OHC. The results suggest that a complex local neuronal circuitry in the OHC area, formed by the dendrites of type-II neurons and modulated by the olivocochlear system, may be a fundamental property of the mammalian cochlea, rather than a curiosity of the primate ear. This network may mediate local feedback control of, and bidirectional communication among, OHCs throughout the cochlear spiral.

  15. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    quality of life of families with children who have a hearing loss or who are fitted with cochlear implants. .... term going into the work force with a severe disability will he be .... balance between professional caution and urgency of treatment.

  16. Cochlear Implants Keep Twin Sisters Learning, Discovering Together

    Science.gov (United States)

    ... Current Issue Past Issues Special Section: Focus on Communication Cochlear Implants Past Issues / Fall 2008 Table of ... in noisy environments—a critical ability in a classroom. Before the second implant, Mia was pulling back ...

  17. COCHLEAR IMPLANTATION IN A PATIENT WITH USHER'S SYNDROME

    OpenAIRE

    Derinsu, Ufuk; Ciprut, Ayca

    2016-01-01

    Usher's Syndrome is an autosomal recessive disorder characterized by congenital hearing loss and retinitis pigmentosa. Usher’s Syndrome patients with severe to profound sensorineural hearing loss can be considered as candidates for cochlear implantation.This case study reports a deaf-blind with Usher's Syndrome who received a cochlear implant, the audiological evaluation is presented and the therapy sessions are discussed. The patient demonstrated good performance overtime after the...

  18. Language understanding and vocabulary of early cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, L; Busch, GW; Sandahl, M

    2013-01-01

    The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level.......The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level....

  19. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  20. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  1. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  2. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    OpenAIRE

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. F...

  3. Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant

    Directory of Open Access Journals (Sweden)

    T. A. K. Nguyen

    2017-11-01

    Full Text Available The peripheral vestibular system is critical for the execution of activities of daily life as it provides movement and orientation information to motor and sensory systems. Patients with bilateral vestibular hypofunction experience a significant decrease in quality of life and have currently no viable treatment option. Vestibular implants could eventually restore vestibular function. Most vestibular implant prototypes to date are modified cochlear implants to fast-track development. These use various objective measurements, such as the electrically evoked compound action potential (eCAP, to supplement behavioral information. We investigated whether eCAPs could be recorded in patients with a vestibulo-cochlear implant. Specifically, eCAPs were successfully recorded for cochlear and vestibular setups, as well as for mixed cochlear-vestibular setups. Similarities and slight differences were found for the recordings of the three setups. These findings demonstrated the feasibility of eCAP recording with a vestibulo-cochlear implant. They could be used in the short term to reduce current spread and avoid activation of non-targeted neurons. More research is warranted to better understand the neural origin of vestibular eCAPs and to utilize them for clinical applications.

  4. Modelling three-dimensional cochlear micromechanics within the guinea pig organ of Corti

    Science.gov (United States)

    Ni, Guangjian; Elliott, Stephen J.

    2018-05-01

    The active amplification process in the mammalian cochlea depends on a complex interaction between cells within the organ of Corti. A three-dimensional (3D) model was developed using the finite element method based on anatomy for the apical end in the guinea pig cochlea, which is comprised of 3D discrete hair cells, 3D continuous membranes and fluid. The basilar membrane, tectorial membrane and the reticular lamina are modelled with orthotropic materials. The Y-shape structures formed by the outer hair cell (OHC), the Deiters' cell and Deiters' cell phalangeal process are also included to account for the structural longitudinal coupling. The motion within the organ of Corti was first simulated in response to a pressure difference loading on the basilar membrane, in order to calculate the passive vibration pattern. Then, the outer hair cells somatic electromotility was implemented by applying a voltage across the OHC walls to investigate its contribution to membranes motion.

  5. Bilateral Cochlear Implants: Maximizing Expected Outcomes.

    Science.gov (United States)

    Wallis, Kate E; Blum, Nathan J; Waryasz, Stephanie A; Augustyn, Marilyn

    Sonia is a 4 years 1 month-year-old girl with Waardenburg syndrome and bilateral sensorineural hearing loss who had bilateral cochlear implants at 2 years 7 months years of age. She is referred to Developmental-Behavioral Pediatrics by her speech/language pathologist because of concerns that her language skills are not progressing as expected after the cochlear implant. At the time of the implant, she communicated using approximately 20 signs and 1 spoken word (mama). At the time of the evaluation (18 months after the implant) she had approximately 70 spoken words (English and Spanish) and innumerable signs that she used to communicate. She could follow 1-step directions in English but had more difficulty after 2-step directions.Sonia was born in Puerto Rico at 40 weeks gestation after an uncomplicated pregnancy. She failed her newborn hearing test and was given hearing aids that did not seem to help.At age 2 years, Sonia, her mother, and younger sister moved to the United States where she was diagnosed with bilateral severe-to-profound hearing loss. Genetic testing led to a diagnosis of Waardenburg syndrome (group of genetic conditions that can cause hearing loss and changes in coloring [pigmentation] of the hair, skin, and eyes). She received bilateral cochlear implants 6 months later.Sonia's mother is primarily Spanish-speaking and mostly communicates with her in Spanish or with gestures but has recently begun to learn American Sign Language (ASL). In a preschool program at a specialized school for the deaf, Sonia is learning both English and ASL. Sonia seems to prefer to use ASL to communicate.Sonia receives speech and language therapy (SLT) 3 times per week (90 minutes total) individually in school and once per week within a group. She is also receiving outpatient SLT once per week. Therapy sessions are completed in English, with the aid of an ASL interpreter. Sonia's language scores remain low, with her receptive skills in the first percentile, and her

  6. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  7. Production of verb tenses in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Sokolovac Ivana

    2016-01-01

    Full Text Available The production of verb tenses leads to better language development of children with cochlear implants. The aim of this study was to assess the acquisition of verb tenses in children with cochlear implants. The sample included 60 children, aged from 9 to 15, with average intellectual abilities. The study group consisted of 30 patients with cochlear implants, with no additional disabilities. The control group consisted of 30 subjects with typical speech - language development and preserved hearing. The acquisition of basic tenses was assessed by 'Corpus for the Assessment of the Use of Tenses' (Dimić, 2003. Significant statistical differences were found in the use of the present tense in children with cochlear implants and hearing children (t=-4.385; p<0.001 as well as in the use of the past tense (t=-4.650; p<0.001, and the future tense (t=-4.269; p<0.001. There was also a significant difference in the use of irregular verb 'go' (t=-3.958; p<0.001, as well as in the combination of the present and the past tense (t=-5.806; p<0.001. The present tense was used correctly by most children with cochlear implants (70%, followed by the past tense (53%, and finally the future tense (23%. Children with cochlear implants, even after several years of re/habilitation, do not reach the grammatical development of children with normal hearing.

  8. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  9. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  10. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Noise-Induced Loss of Hair Cells and Cochlear Synaptopathy Are Mediated by the Activation of AMPK

    Science.gov (United States)

    Hill, Kayla; Yuan, Hu; Wang, Xianren

    2016-01-01

    Noise-induced hearing loss (NIHL) is a major unresolved public health problem. Here, we investigate pathomechanisms of sensory hair cell death and suggest a novel target for protective intervention. Cellular survival depends upon maintenance of energy homeostasis, largely by AMP-activated protein kinase (AMPK). In response to a noise exposure in CBA/J mice, the levels of phosphorylated AMPKα increased in hair cells in a noise intensity-dependent manner. Inhibition of AMPK via siRNA or the pharmacological inhibitor compound C attenuated noise-induced loss of outer hair cells (OHCs) and synaptic ribbons, and preserved auditory function. Additionally, noise exposure increased the activity of the upstream AMPK kinase liver kinase B1 (LKB1) in cochlear tissues. The inhibition of LKB1 by siRNA attenuated the noise-increased phosphorylation of AMPKα in OHCs, reduced the loss of inner hair cell synaptic ribbons and OHCs, and protected against NIHL. These results indicate that noise exposure induces hair cell death and synaptopathy by activating AMPK via LKB1-mediated pathways. Targeting these pathways may provide a novel route to prevent NIHL. SIGNIFICANCE STATEMENT Our results demonstrate for the first time that the activation of AMP-activated protein kinase (AMPK) α in sensory hair cells is noise intensity dependent and contributes to noise-induced hearing loss by mediating the loss of inner hair cell synaptic ribbons and outer hair cells. Noise induces the phosphorylation of AMPKα1 by liver kinase B1 (LKB1), triggered by changes in intracellular ATP levels. The inhibition of AMPK activation by silencing AMPK or LKB1, or with the pharmacological inhibitor compound C, reduced outer hair cell and synaptic ribbon loss as well as noise-induced hearing loss. This study provides new insights into mechanisms of noise-induced hearing loss and suggests novel interventions for the prevention of the loss of sensory hair cells and cochlear synaptopathy. PMID:27413159

  12. Laser amplification in excited dielectrics

    DEFF Research Database (Denmark)

    Winkler, Thomas; Haahr-Lillevang, Lasse; Sarpe, Cristian

    2018-01-01

    Wide-bandgap dielectrics such as glasses or water are transparent at visible and infrared wavelengths. This changes when they are exposed to ultrashort and highly intense laser pulses. Different interaction mechanisms lead to the appearance of various transient nonlinear optical phenomena. Using...... these, the optical properties of dielectrics can be controlled from the transparent to the metal-like state. Here we expand this range by a yet unexplored mechanism in excited dielectrics: amplification. In a two-colour pump-probe experiment, we show that a 400nm femtosecond laser pulse is coherently...

  13. Telomerase Repeated Amplification Protocol (TRAP).

    Science.gov (United States)

    Mender, Ilgen; Shay, Jerry W

    2015-11-20

    Telomeres are found at the end of eukaryotic linear chromosomes, and proteins that bind to telomeres protect DNA from being recognized as double-strand breaks thus preventing end-to-end fusions (Griffith et al. , 1999). However, due to the end replication problem and other factors such as oxidative damage, the limited life span of cultured cells (Hayflick limit) results in progressive shortening of these protective structures (Hayflick and Moorhead, 1961; Olovnikov, 1973). The ribonucleoprotein enzyme complex telomerase-consisting of a protein catalytic component hTERT and a functional RNA component hTR or hTERC - counteracts telomere shortening by adding telomeric repeats to the end of chromosomes in ~90% of primary human tumors and in some transiently proliferating stem-like cells (Shay and Wright, 1996; Shay and Wright, 2001). This results in continuous proliferation of cells which is a hallmark of cancer. Therefore, telomere biology has a central role in aging, cancer progression/metastasis as well as targeted cancer therapies. There are commonly used methods in telomere biology such as Telomere Restriction Fragment (TRF) (Mender and Shay, 2015b), Telomere Repeat Amplification Protocol (TRAP) and Telomere dysfunction Induced Foci (TIF) analysis (Mender and Shay, 2015a). In this detailed protocol we describe Telomere Repeat Amplification Protocol (TRAP). The TRAP assay is a popular method to determine telomerase activity in mammalian cells and tissue samples (Kim et al. , 1994). The TRAP assay includes three steps: extension, amplification, and detection of telomerase products. In the extension step, telomeric repeats are added to the telomerase substrate (which is actually a non telomeric oligonucleotide, TS) by telomerase. In the amplification step, the extension products are amplified by the polymerase chain reaction (PCR) using specific primers (TS upstream primer and ACX downstream primer) and in the detection step, the presence or absence of telomerase is

  14. Resonant primordial gravitational waves amplification

    Directory of Open Access Journals (Sweden)

    Chunshan Lin

    2016-01-01

    Full Text Available We propose a mechanism to evade the Lyth bound in models of inflation. We minimally extend the conventional single-field inflation model in general relativity (GR to a theory with non-vanishing graviton mass in the very early universe. The modification primarily affects the tensor perturbation, while the scalar and vector perturbations are the same as the ones in GR with a single scalar field at least at the level of linear perturbation theory. During the reheating stage, the graviton mass oscillates coherently and leads to resonant amplification of the primordial tensor perturbation. After reheating the graviton mass vanishes and we recover GR.

  15. Noise-induced nitrotyrosine increase and outer hair cell death in guinea pig cochlea.

    Science.gov (United States)

    Han, Wei-ju; Shi, Xiao-rui; Nuttall, Alfred

    2013-01-01

    Modern research has provided new insights into the biological mechanisms of noise-induced hearing loss, and a number of studies showed the appearance of increased reactive oxygen species (ROS) and reactive nitrogen species (RNS) during and after noise exposure. This study was designed to investigate the noise exposure induced nitrotyrosine change and the mechanism of outer hair cells death in guinea pig cochlea. Thirty guinea pigs were used in this study. The experimental animals were either exposed for 4 hours per day to broadband noise at 122 dB SPL (A-weighted) for 2 consecutive days or perfused cochleae with 5 mg/ml of the SIN1 solutions, an exogenous NO and superoxide donor, for 30 minutes. Then the cochleae of the animals were dissected. Propidium iodide (PI), a DNA intercalating fluorescent probe, was used to trace morphological changes in OHC nuclei. The distribution of nitrotyrosine (NT) in the organ of Corti and the cochlear lateral wall tissue from the guinea pigs were examined using fluorescence immunohistochemistry method. Whole mounts of organ of Corti were prepared. Morphological and fluorescent changes were examined under a confocal microscope. Either after noise exposure or after SIN1 perfusion, outer hair cells (OHCs) death with characteristics of both apoptotic and necrotic degradation appeared. Nitrotyrosine immunolabeling could be observed in the OHCs from the control animals. After noise exposure, NT immunostaining became much greater than the control animals in OHCs. The apoptotic OHC has significant increase of nitrotyrosine in and around the nucleus following noise exposure. In the normal later wall of cochleae, relatively weak nitrotyrosine immunolabeling could be observed. After noise exposure, nitrotyrosine immunoactivity became stronger in stria vascularis. Noise exposure induced increase of nitrotyrosine production is associated with OHCs death suggesting reactive nitrogen species participation in the cochlear pathophysiology of noise

  16. Outer grid strap protruding spring repair apparatus

    International Nuclear Information System (INIS)

    Widener, W.H.

    1987-01-01

    This patent describes a nuclear fuel assembly grid spring repair apparatus for repairing a spring formed on an outer strap of a fuel assembly grid and having a portion protruding outwardly beyond the strap, the apparatus comprising: (a) a support frame defining an opening and having means defining a guide channel extending along the opening in a first direction; (b) means mounted on the frame and being adjustable for attaching the frame to the outer strap of the support grid so that the frame opening is aligned with the outwardly protruding spring on the outer strap; (c) an outer slide having a passageway defined therethrough and being mounted in the guide channel for reciprocable movement along the frame opening in the first direction for aligning the passageway with the outwardly protruding portion of the spring on the outer strap. The outer slide also has means defining a guide way extending along the passageway in a second direction generally orthogonal to the first direction; (d) a spring reset mechanism being operable for resetting the protruding spring to a nonprotruding position relative to the outer strap when the mechanism is aligned with the protruding portion of the spring; and (e) an inner slide supporting the spring reset mechanism and being mounted to the guide way for reciprocable movement along the passageway of the outer slide in the second direction for aligning the spring reset mechanism with the protruding portion of the spring on the outer strap

  17. Binaural enhancement for bilateral cochlear implant users.

    Science.gov (United States)

    Brown, Christopher A

    2014-01-01

    Bilateral cochlear implant (BCI) users receive limited binaural cues and, thus, show little improvement to speech intelligibility from spatial cues. The feasibility of a method for enhancing the binaural cues available to BCI users is investigated. This involved extending interaural differences of levels, which typically are restricted to high frequencies, into the low-frequency region. Speech intelligibility was measured in BCI users listening over headphones and with direct stimulation, with a target talker presented to one side of the head in the presence of a masker talker on the other side. Spatial separation was achieved by applying either naturally occurring binaural cues or enhanced cues. In this listening configuration, BCI patients showed greater speech intelligibility with the enhanced binaural cues than with naturally occurring binaural cues. In some situations, it is possible for BCI users to achieve greater speech intelligibility when binaural cues are enhanced by applying interaural differences of levels in the low-frequency region.

  18. Accurate guitar tuning by cochlear implant musicians.

    Directory of Open Access Journals (Sweden)

    Thomas Lu

    Full Text Available Modern cochlear implant (CI users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task.

  19. Ultra-Wideband Transceivers for Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Reisenzahn Alexander

    2005-01-01

    Full Text Available Ultra-wideband (UWB radio offers low power consumption, low power spectral density, high immunity against interference, and other benefits, not only for consumer electronics, but also for medical devices. A cochlear implant (CI is an electronic hearing apparatus, requiring a wireless link through human tissue. In this paper we propose an UWB link for a data rate of Mbps and a propagation distance up to 500 mm. Transmitters with step recovery diode and transistor pulse generators are proposed. Two types of antennas and their filter characteristics in the UWB spectrum will be discussed. An ultra-low-power back tunnel diode receiver prototype is described and compared with conventional detector receivers.

  20. Cochlear vertebral entrapment syndrome: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Liu Chinghsiung; Lin Shinnkuang E-mail: sk1943@adm.cgmh.org.tw; Chang Yeujhy

    2001-11-01

    The authors describe a patient with isolated involvement of vestibulocochlear nerve by a huge vascular loop from vertebral dolichoectasia. No other neurological deficit was found except for unilateral hearing loss. Abnormal brainstem auditory evoked potential study indicated a retrocochlear lesion. The brain computed tomography (CT) and magnetic resonance imaging (MRI) studies demonstrated an abnormally enhanced vascular lesion impinged on the left porus acusticus with a displacement of the brainstem to the right. There was no infarction in the brainstem. A cerebral angiography demonstrated a megadolichoectatic horizontal loop at the intracranial portion of the left vertebral artery. There was no thrombus or atherosclerosis in the vertebrobasilar system. A mechanical compression by a vascular loop is the only possible pathogenesis for hearing loss. The authors diagnose this condition as cochlear vertebral entrapment syndrome.

  1. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang [Dept. of Radiology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)], e-mail: cjr.wzhch@vip.163.com; Mo, Lingyan [Dept. of Otorhinolaryngology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)

    2013-04-15

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.

  2. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    International Nuclear Information System (INIS)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang; Mo, Lingyan

    2013-01-01

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was 2.0 mm in 11 ears (20.4%). The IAC diameter was 3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC

  3. [Cochlear implants in the social courts].

    Science.gov (United States)

    Lottner, A; Iro, H; Schützenberger, A; Hoppe, U

    2018-02-01

    Since the indication for receiving a cochlear implant (CI) has widened (single-sided deafness [SSD], electric acoustic stimulation [EAS], bilateral CI, CI for long-term deafness), more and more patients come into consideration for such a treatment. Hence, disputes increasingly arise between patients and their insurance companies concerning the question of whether surgery and follow-up treatment have to be paid for by statutory health insurance. This work provides an overview of judgments rendered by the German social courts. We investigated whether and in which cases it is advisable for a patient to go to court, and how long the proceedings may take. We looked for judgments in the two biggest commercial legal databases and in the database of the German social courts, using combinations of the search parameters "Cochlear," "Cochlea," "Implant," and "Implantat." Three verdicts were attained by directly contacting the court; another one was mentioned in an article. The reviewed judgements were issued between 2003 and 2017. A total of 12 judgments were found. The patients won in all but one of the main proceedings. The case that was lost concerned exceptional circumstances. One patient didn't get the desired interim measure, but won in the main proceedings. The proceedings took between 1 year and 8 months, and 9 years and 5 months. Despite the amount of time the patient has to invest, taking legal action is worthwhile. The proceedings at the social courts are generally exempt from charges. In most cases, the statutory health insurance is ordered to pay for a CI.

  4. Parental perspectives of children using cochlear implant.

    Science.gov (United States)

    Stefanini, Marcela Roselin; Morettin, Marina; Zabeu, Julia Speranza; Bevilacqua, Maria Cecília; Moret, Adriane Lima Mortari

    2014-01-01

    To evaluate the parents' perspective with regard to evolution of their child with cochlear implant (CI). This was a cross-sectional prospective study conducted at the Centro de Pesquisas Audiológicas of Hospital de Reabilitação de Anomalias Craniofaciais of Universidade de São Paulo. The selection of the sample was performed from the spontaneous demand, among the months from July to December 2011. The final sample comprised 50 parents or guardians of children using CI, with minimum 1 year and maximum of 3 years of device use. The translated and adapted to Brazilian Portuguese version of the questionnaire "Perspectives of parents of children with cochlear implants" was applied. This instrument consists of 74 questions and allows quantification of the parents' perspective on subscales that illustrate the situation of the child and family. Each question has five options scored from one to five responses. The Spearman test for comparison of results between the subscales was applied. The social relationships, self-sufficiency, and communication subscales showed the highest mean score, whereas the worst score was for child support subscale, reflecting the independence and autonomy of the patients. The correlation between the child subscales was realized, and the results showed themselves significant and positive for communication subscale of communication with all others subscales. The family subscales also had a positive correlation with the communication, education, and self-sufficiency. These results demonstrate that parents have good expectations regarding communication, independence, and social participation of children after CI surgery, and this questionnaire is a useful tool for use in clinical practice.

  5. Effect of unilateral and simultaneous bilateral cochlear implantation on tinnitus : A Prospective Study

    NARCIS (Netherlands)

    van Zon, Alice; Smulders, Yvette E.; Ramakers, Geerte G. J.; Stegeman, Inge; Smit, Adriana L.; Van Zanten, Gijsbert A.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H. M.; Mylanus, Emmanuel A. M.; Huinck, Wendy J.; Topsakal, Vedat; Tange, Rinze A.; Grolman, Wilko

    Objectives/HypothesisTo determine the effect of cochlear implantation on tinnitus perception in patients with severe bilateral postlingual sensorineural hearing loss and to demonstrate possible differences between unilateral and bilateral cochlear implantation. Study DesignProspective study.

  6. Risk Perception and Social Amplification

    International Nuclear Information System (INIS)

    Smith, R.E.

    2001-01-01

    This paper seeks to consider social amplification as it applies to risk perception. Perceptions of the magnitude of a risk are conditioned by issues such as the degree of uncertainty in probability and consequences, the nature of the consequences and the relative weightings placed on probability and consequences. Risk perceptions are also influenced by factors such as confidence in the operator of an industrial process, trust in the regulator and the perceived fairness of regulatory decision-making. Different people may hold different views about these issues and there may also be difficulties in communication. The paper identifies and discusses self-reinforcing mechanisms, which will be labelled 'lock-in' here. They appear to apply in many situations where social amplification is observed. Historically, the term 'lock-in' has been applied mainly in the technological context but, in this paper, four types of lock-in are identified, namely scientific/technological, economic, social and institutional lock-in. One type of lock-in tends to lead to the next and all are buttressed by people's general acceptance of the familiar, fear of the unknown and resistance to change. The regulator seeks to make decisions which achieve the common good rather than supporting or perpetuating any set of vested interests. In this regard the locked-in positions of stakeholders, whether organisations, interest groups, or individual members of the public, are obstacles and challenges. Existing methods of consultation are unsatisfactory in terms of achieving a proper and productive level of dialogue with stakeholders

  7. Improved method of measurement for outer leak

    International Nuclear Information System (INIS)

    Xu Guang

    2012-01-01

    Pneumatic pipeline is installed for the airborne radioactivity measurement equipment, air tightness and outer leak rate are essential for the testing of the characteristics, both in the national criteria and ISO standards, an improved practical method is available for the measurement of the outer air leak rate based on the engineering experiences for the equipment acceptance and testing procedure. (authors)

  8. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    Science.gov (United States)

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  10. Image Registration of Cochlear µCT Data Using Heat Distribution Similarity

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Vera, Sergio; Fagertun, Jens

    2015-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Good non-rigid alignment of high-resolution cochlear μCT data is a challenging task. In this paper we study the use of heat distribution similarity between sampl...

  11. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  12. Distinct roles of Eps8 in the maturation of cochlear and vestibular hair cells.

    Science.gov (United States)

    Tavazzani, Elisa; Spaiardi, Paolo; Zampini, Valeria; Contini, Donatella; Manca, Marco; Russo, Giancarlo; Prigioni, Ivo; Marcotti, Walter; Masetto, Sergio

    2016-07-22

    Several genetic mutations affecting the development and function of mammalian hair cells have been shown to cause deafness but not vestibular defects, most likely because vestibular deficits are sometimes centrally compensated. The study of hair cell physiology is thus a powerful direct approach to ascertain the functional status of the vestibular end organs. Deletion of Epidermal growth factor receptor pathway substrate 8 (Eps8), a gene involved in actin remodeling, has been shown to cause deafness in mice. While both inner and outer hair cells from Eps8 knockout (KO) mice showed abnormally short stereocilia, inner hair cells (IHCs) also failed to acquire mature-type ion channels. Despite the fact that Eps8 is also expressed in vestibular hair cells, Eps8 KO mice show no vestibular deficits. In the present study we have investigated the properties of vestibular Type I and Type II hair cells in Eps8-KO mice and compared them to those of cochlear IHCs. In the absence of Eps8, vestibular hair cells show normally long kinocilia, significantly shorter stereocilia and a normal pattern of basolateral voltage-dependent ion channels. We have also found that while vestibular hair cells from Eps8 KO mice show normal voltage responses to injected sinusoidal currents, which were used to mimic the mechanoelectrical transducer current, IHCs lose their ability to synchronize their responses to the stimulus. We conclude that the absence of Eps8 produces a weaker phenotype in vestibular hair cells compared to cochlear IHCs, since it affects the hair bundle morphology but not the basolateral membrane currents. This difference is likely to explain the absence of obvious vestibular dysfunction in Eps8 KO mice. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  13. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

    Science.gov (United States)

    Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C

    1995-03-01

    The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or

  14. Direct testing of the biasing effect of manipulations of endolymphatic pressure on cochlear mechanical function

    Science.gov (United States)

    LePage, Eric; Avan, Paul

    2015-12-01

    The history of cochlear mechanical investigations has been carried out in two largely separate sets of endeavours; those interested in auditory processing in animal models and those interested in the origin of adverse vestibular symptoms in humans. In respect of the first, mechanical vibratory data is considered pathological and not representative of pristine behaviour if it departs from the reigning model of sharp tuning and high hearing sensitivity. Conversely, when the description of the pathological behaviour is the focus, fluid movements responsible for hearing loss and vestibular symptoms dominate. Yet both extensive sets of data possess a common factor now being reconsidered for its potential to shed light on the mechanisms in general. The common factor is a mechanical bias — the departure of cochlear epithelial membranes from their usual resting position. In both cases the bias modulates hearing sensitivity and distorts tuning characteristics. Indeed several early sets of guinea pig mechanical data were dismissed as "pathological" when in hindsight, the primary effect influencing the data was not loss of outer hair cell function per se, but a mechanical bias unknowingly introduced in process of making the measurement. Such biases in the displacement of the basilar membrane from its position are common, and may be caused by low-frequency sounds (topically including infrasound) or by variations in fluid volume in the chambers particularly applying the case of endolymphatic hydrops. Most biases are quantified in terms of visualisation of fluid volume change, electric potential changes and otoacoustic emissions. Notably many previous studies have also searched for raised pressures with negative results. Yet these repeated findings are contrary to the widespread notion that, at least when homeostasis is lost, it is a rise in endolymphatic pressure which is responsible for membrane rupture and Meniere's attacks. This current investigation in Mongolian gerbils

  15. Establishment of a model of cochlear lesions in rats to study potential gene therapy for sensorineural hearing loss.

    Science.gov (United States)

    Wang, Ye; Qiao, Li; Chen, Yang; Wen, Liting; Yue, Bo; Qiu, Jianhua; Wu, Shengxi

    2015-12-01

    Sensorineural hearing loss seriously influences a patient's daily life, and no effective treatments exist to date. Gene therapy is a potential treatment for regenerating hair cells to restore hearing. In this study, we established a cochlear lesions model to study hair cell regeneration by co-administration of kanamycin and furosemide. After the injections, we assessed the survival of outer hair cells (OHC), inner hair cells (IHC), supporting cells (SC), spiral ganglion neurons (SGN) and peripheral axons. Moreover, we used two viral vectors to detect the transgene distribution. Our results showed at 12h post-treatment, numerous OHC were missing in the basal turn. At 24h post-treatment, all OHCs in basal half of the cochlea were lost, and by 48h, OHC loss had spread to the apical coil. Four days after the injections, all OHCs were absent. At 1mo post-treatment, the organ of Corti had collapsed. In contrast, most of the SC remained 4d after the injections. The loss of SGN and peripheral axons was consistent with this time course post-treatment. The results of transgene distribution suggested the correlative gene can be transferred into the organ of Corti using adenoviruses (AdV) vectors and lentiviruses (LV) vectors in our cochlear lesion model. We assessed the details of HC death at more time point and chosen the time point for gene transfer in this model. We conclude that this cochlear lesion model would be suitable for the study of hair cell regeneration. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Stronger efferent suppression of cochlear neural potentials by contralateral acoustic stimulation in awake than in anesthetized chinchilla

    Directory of Open Access Journals (Sweden)

    Cristian eAedo

    2015-03-01

    Full Text Available There are two types of sensory cells in the mammalian cochlea, inner hair cells, which make synaptic contact with auditory-nerve afferent fibers, and outer hair cells that are innervated by crossed and uncrossed medial olivocochlear (MOC efferent fibers. Contralateral acoustic stimulation activates the uncrossed efferent MOC fibers reducing cochlear neural responses, thus modifying the input to the central auditory system. The chinchilla, among all studied mammals, displays the lowest percentage of uncrossed MOC fibers raising questions about the strength and frequency distribution of the contralateral-sound effect in this species. On the other hand, MOC effects on cochlear sensitivity have been mainly studied in anesthetized animals and since the MOC-neuron activity depends on the level of anesthesia, it is important to assess the influence of anesthesia in the strength of efferent effects. Seven adult chinchillas (Chinchilla laniger were chronically implanted with round-window electrodes in both cochleae. We compared the effect of contralateral sound in awake and anesthetized condition. Compound action potentials (CAP and cochlear microphonics (CM were measured in the ipsilateral cochlea in response to tones in absence and presence of contralateral sound. Control measurements performed after middle-ear muscles section in one animal discarded any possible middle-ear reflex activation. Contralateral sound produced CAP amplitude reductions in all chinchillas, with suppression effects greater by about 1-3 dB in awake than in anesthetized animals. In contrast, CM amplitude increases of up to 1.9 dB were found in only three awake chinchillas. In both conditions the strongest efferent effects were produced by contralateral tones at frequencies equal or close to those of ipsilateral tones. Contralateral CAP suppressions for 1-6 kHz ipsilateral tones corresponded to a span of uncrossed MOC fiber innervation reaching at least the central third of the

  17. Stronger efferent suppression of cochlear neural potentials by contralateral acoustic stimulation in awake than in anesthetized chinchilla.

    Science.gov (United States)

    Aedo, Cristian; Tapia, Eduardo; Pavez, Elizabeth; Elgueda, Diego; Delano, Paul H; Robles, Luis

    2015-01-01

    There are two types of sensory cells in the mammalian cochlea, inner hair cells, which make synaptic contact with auditory-nerve afferent fibers, and outer hair cells that are innervated by crossed and uncrossed medial olivocochlear (MOC) efferent fibers. Contralateral acoustic stimulation activates the uncrossed efferent MOC fibers reducing cochlear neural responses, thus modifying the input to the central auditory system. The chinchilla, among all studied mammals, displays the lowest percentage of uncrossed MOC fibers raising questions about the strength and frequency distribution of the contralateral-sound effect in this species. On the other hand, MOC effects on cochlear sensitivity have been mainly studied in anesthetized animals and since the MOC-neuron activity depends on the level of anesthesia, it is important to assess the influence of anesthesia in the strength of efferent effects. Seven adult chinchillas (Chinchilla laniger) were chronically implanted with round-window electrodes in both cochleae. We compared the effect of contralateral sound in awake and anesthetized condition. Compound action potentials (CAP) and cochlear microphonics (CM) were measured in the ipsilateral cochlea in response to tones in absence and presence of contralateral sound. Control measurements performed after middle-ear muscles section in one animal discarded any possible middle-ear reflex activation. Contralateral sound produced CAP amplitude reductions in all chinchillas, with suppression effects greater by about 1-3 dB in awake than in anesthetized animals. In contrast, CM amplitude increases of up to 1.9 dB were found in only three awake chinchillas. In both conditions the strongest efferent effects were produced by contralateral tones at frequencies equal or close to those of ipsilateral tones. Contralateral CAP suppressions for 1-6 kHz ipsilateral tones corresponded to a span of uncrossed MOC fiber innervation reaching at least the central third of the chinchilla cochlea.

  18. Multiscale image contrast amplification (MUSICA)

    Science.gov (United States)

    Vuylsteke, Pieter; Schoeters, Emile P.

    1994-05-01

    This article presents a novel approach to the problem of detail contrast enhancement, based on multiresolution representation of the original image. The image is decomposed into a weighted sum of smooth, localized, 2D basis functions at multiple scales. Each transform coefficient represents the amount of local detail at some specific scale and at a specific position in the image. Detail contrast is enhanced by non-linear amplification of the transform coefficients. An inverse transform is then applied to the modified coefficients. This yields a uniformly contrast- enhanced image without artefacts. The MUSICA-algorithm is being applied routinely to computed radiography images of chest, skull, spine, shoulder, pelvis, extremities, and abdomen examinations, with excellent acceptance. It is useful for a wide range of applications in the medical, graphical, and industrial area.

  19. Measuring the amplification of attention.

    Science.gov (United States)

    Blaser, E; Sperling, G; Lu, Z L

    1999-09-28

    An ambiguous motion paradigm, in which the direction of apparent motion is determined by salience (i.e., the extent to which an area is perceived as figure versus ground), is used to assay the amplification of color by attention to color. In the red-green colored gratings used in these experiments, without attention instructions, salience depends on the chromaticity difference between colored stripes embedded in the motion sequence and the yellow background. Selective attention to red (or to green) alters the perceived direction of motion and is found to be equivalent to increasing the physical redness (or greenness) by 25-117%, depending on the observer and color. Whereas attention to a color drastically alters the salience of that color, it leaves color appearance unchanged. A computational model, which embodies separate, parallel pathways for object perception and for salience, accounts for 99% of the variance of the experimental data.

  20. Risk Perception and Social Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.E. [Environment Agency (United Kingdom)

    2001-07-01

    This paper seeks to consider social amplification as it applies to risk perception. Perceptions of the magnitude of a risk are conditioned by issues such as the degree of uncertainty in probability and consequences, the nature of the consequences and the relative weightings placed on probability and consequences. Risk perceptions are also influenced by factors such as confidence in the operator of an industrial process, trust in the regulator and the perceived fairness of regulatory decision-making. Different people may hold different views about these issues and there may also be difficulties in communication. The paper identifies and discusses self-reinforcing mechanisms, which will be labelled 'lock-in' here. They appear to apply in many situations where social amplification is observed. Historically, the term 'lock-in' has been applied mainly in the technological context but, in this paper, four types of lock-in are identified, namely scientific/technological, economic, social and institutional lock-in. One type of lock-in tends to lead to the next and all are buttressed by people's general acceptance of the familiar, fear of the unknown and resistance to change. The regulator seeks to make decisions which achieve the common good rather than supporting or perpetuating any set of vested interests. In this regard the locked-in positions of stakeholders, whether organisations, interest groups, or individual members of the public, are obstacles and challenges. Existing methods of consultation are unsatisfactory in terms of achieving a proper and productive level of dialogue with stakeholders.

  1. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  2. Hyperbaric oxygen upregulates cochlear constitutive nitric oxide synthase

    Directory of Open Access Journals (Sweden)

    Kao Ming-Ching

    2011-02-01

    Full Text Available Abstract Background Hyperbaric oxygen therapy (HBOT is a known adjuvant for treating ischemia-related inner ear diseases. Controversies still exist in the role of HBOT in cochlear diseases. Few studies to date have investigated the cellular changes that occur in inner ears after HBOT. Nitric oxide, which is synthesized by nitric oxide synthase (NOS, is an important signaling molecule in cochlear physiology and pathology. Here we investigated the effects of hyperbaric oxygen on eardrum morphology, cochlear function and expression of NOS isoforms in cochlear substructures after repetitive HBOT in guinea pigs. Results Minor changes in the eardrum were observed after repetitive HBOT, which did not result in a significant hearing threshold shift by tone burst auditory brainstem responses. A differential effect of HBOT on the expression of NOS isoforms was identified. Upregulation of constitutive NOS (nNOS and eNOS was found in the substructures of the cochlea after HBOT, but inducible NOS was not found in normal or HBOT animals, as shown by immunohistochemistry. There was no obvious DNA fragmentation present in this HBOT animal model. Conclusions The present evidence indicates that the customary HBOT protocol may increase constitutive NOS expression but such upregulation did not cause cell death in the treated cochlea. The cochlear morphology and auditory function are consequently not changed through the protocol.

  3. Verbal Working Memory in Children With Cochlear Implants

    Science.gov (United States)

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  4. Exploring the experiences of teenagers with cochlear implants.

    Science.gov (United States)

    Watson, Victoria; Verschuur, Carl; Lathlean, Judith

    2016-11-01

    Teenage cochlear implant users' perceptions of deafness, surgery, fitting of the device and life as a cochlear implant wearer were explored in order to gain a more comprehensive understanding of teenagers' experiences of living with the device. Semi-structured in-depth interviews were undertaken and analysed using thematic analysis. Ten teenagers aged 14-16 years with at least one cochlear implant were interviewed. Seven teenagers experienced great pre-operative anxiety and two reported significant post-operative pain. Four of the teenagers described a mismatch between their expectations and the disappointing reality of adjusting to the device. However, all the teenagers reported an enhanced sense of well-being as a result of being able to interact more easily with their world around them. The teenagers differed in the extent to which they identified with the hearing and deaf world. Despite the early challenges, over time the teenagers experienced many functional and psychosocial benefits. Most felt their lives were now easier as a result of the cochlear implant(s). They described complex, flexible identities. By giving prominence to the teenagers' voices this study has added new knowledge concerning their experience of surgery. The findings also more fully revealed the challenges of adjusting to the device and the impact of having a cochlear implant on the teenagers' identities. Clinical recommendations are made to address the gaps in service highlighted by these findings.

  5. Prevalence of inner ear anomalies among cochlear implant candidates.

    Science.gov (United States)

    Aldhafeeri, Ahmad M; Alsanosi, Abdulrahman A

    2016-10-01

    To determine the prevalence of inner ear anomalies and the frequency of different anomaly types among cochlear implant recipients. This study included a retrospective chart review of all patients who received cochlear implants between January 2009 and January 2013 in King Abdulaziz University Hospital cochlear implant program in Riyadh, Saudi Arabia. All subjects underwent thin-cut CT of the temporal bone and MRI. The collected data included age, gender, and CT and MRI findings regarding temporal bone anomalies. Patients with any identified congenital inner ear anomalies were included in the study.  In total, 316 patients' cases were reviewed. Inner ear malformations were identified in 24 patients, which represented a prevalence of 7.5%. Among these 24 patients, 8 (33.3%) presented with a large vestibular aqueduct (LVA), 8 (33.3%) semicircular canal (SCC) dysplasia, 7 (29.1%) classical Mondini deformity, and one (4.1%) cochlear hypoplasia. The prevalence of inner ear anomalies among cochlear implant recipients was 7.5%. This result is consistent with findings worldwide. The most common anomalies were LVA and SCC hypoplasia; by contrast, in other regions, the most common anomaly is either the Mondini deformity, or LVA.

  6. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  7. Cochlear injury and adaptive plasticity of the auditory cortex

    Directory of Open Access Journals (Sweden)

    ANNA R. eFETONI

    2015-02-01

    Full Text Available Growing evidence suggests that cochlear stressors as noise exposure and aging can induce homeostatic/maladaptive changes in the central auditory system from the brainstem to the cortex. Studies centered on such changes have revealed several mechanisms that operate in the context of sensory disruption after insult (noise trauma, drug- or age-related injury. The oxidative stress is central to current theories of induced sensory neural hearing loss and aging, and interventions to attenuate the hearing loss are based on antioxidant agent. The present review addresses the recent literature on the alterations in hair cells and spiral ganglion neurons due to noise-induced oxidative stress in the cochlea, as well on the impact of cochlear damage on the auditory cortex neurons. The emerging image emphasizes that noise-induced deafferentation and upward spread of cochlear damage is associated with the altered dendritic architecture of auditory pyramidal neurons. The cortical modifications may be reversed by treatment with antioxidants counteracting the cochlear redox imbalance. These findings open new therapeutic approaches to treat the functional consequences of the cortical reorganization following cochlear damage.

  8. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  9. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  10. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    Science.gov (United States)

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  11. Incorporation of squalene into rod outer segments

    International Nuclear Information System (INIS)

    Keller, R.K.; Fliesler, S.J.

    1990-01-01

    We have reported previously that squalene is the major radiolabeled nonsaponifiable lipid product derived from [ 3 H]acetate in short term incubations of frog retinas. In the present study, we demonstrate that newly synthesized squalene is incorporated into rod outer segments under similar in vitro conditions. We show further that squalene is an endogenous constituent of frog rod outer segment membranes; its concentration is approximately 9.5 nmol/mumol of phospholipid or about 9% of the level of cholesterol. Pulse-chase experiments with radiolabeled precursors revealed no metabolism of outer segment squalene to sterols in up to 20 h of chase. Taken together with our previous absolute rate studies, these results suggest that most, if not all, of the squalene synthesized by the frog retina is transported to rod outer segments. Synthesis of protein is not required for squalene transport since puromycin had no effect on squalene incorporation into outer segments. Conversely, inhibition of isoprenoid synthesis with mevinolin had no effect on the incorporation of opsin into the outer segment. These latter results support the conclusion that the de novo synthesis and subsequent intracellular trafficking of opsin and isoprenoid lipids destined for the outer segment occur via independent mechanisms

  12. Small RNAs controlling outer membrane porins

    DEFF Research Database (Denmark)

    Valentin-Hansen, Poul; Johansen, Jesper; Rasmussen, Anders A

    2007-01-01

    are key regulators of environmental stress. Recent work has revealed an intimate interplay between small RNA regulation of outer membrane proteins and the stress-induced sigmaE-signalling system, which has an essential role in the maintenance of the integrity of the outer membrane.......Gene regulation by small non-coding RNAs has been recognized as an important post-transcriptional regulatory mechanism for several years. In Gram-negative bacteria such as Escherichia coli and Salmonella, these RNAs control stress response and translation of outer membrane proteins and therefore...

  13. Effects of chronic furosemide on central neural hyperactivity and cochlear thresholds after cochlear trauma in guinea pig

    Directory of Open Access Journals (Sweden)

    Wilhelmina eMulders

    2014-08-01

    Full Text Available Increased neuronal spontaneous firing rates have been observed throughout the central auditory system after trauma to the cochlea and this hyperactivity is believed to be associated with the phantom perception of tinnitus. Previously we have shown in an animal model of hearing loss, that an acute injection with furosemide can significantly decrease hyperactivity after cochlear trauma and eliminate behavioural evidence of tinnitus of early onset. However, furosemide also has the potential to affect cochlear thresholds. In this paper we measured the effects of a chronic (daily injections for 7 days furosemide treatment on the spontaneous firing rate of inferior colliculus neurons and on cochlear thresholds in order to establish whether a beneficial effect on hyperactivity can be obtained without causing additional hearing loss. Guinea pigs were exposed to a 10 kHz, 124dB, 2 hour acoustic trauma, and after 5 days of recovery, were given daily i.p. injections of 80mg/kg furosemide or an equivalent amount of saline. The activity of single IC neurons was recorded 24 hours following the last injection. The furosemide treatment had no effect on cochlear thresholds compared to saline injections but did result in significant reductions in spontaneous firing rates recorded in inferior colliculus. These results that suggest a long term beneficial effect of furosemide on hyperactivity after cochlear trauma may be achievable without detrimental effects on hearing, which is important when considering therapeutic potential.

  14. 4-aminopyridine in scala media reversibly alters the cochlear potentials and suppresses electrically evoked oto-acoustic emissions.

    Science.gov (United States)

    Kirk, D L; Yates, G K

    1998-01-01

    Iontophoresis of 4-aminopyridine into scala media of the guinea pig cochlea caused elevation of the thresholds of the compound action potential of the auditory nerve, loss of amplitude of the extracellular cochlear microphonic response (CM), increase in the endocochlear potential (EP) and reduction in the amplitude of electrically evoked oto-acoustic emissions (EEOAEs). These changes were reversible over 10-20 min. The reciprocity of the changes in the CM and the EP was consistent with an interruption of both DC and AC currents through outer hair cells (OHCs), probably by blockade of mechano-electrical transduction (MET) channels in OHCs. Reductions in EEOAEs were consistent with the extrinsically applied generating current entering the OHC via the MET channels. Implications for the activation of OHC electromotility in vivo are discussed.

  15. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  16. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  17. Probing the Electrode–Neuron Interface With Focused Cochlear Implant Stimulation

    Science.gov (United States)

    Bierer, Julie Arenberg

    2010-01-01

    Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode–neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode–neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception. PMID:20724356

  18. Migration of cochlear lateral wall cells.

    Science.gov (United States)

    Dunaway, George; Mhaskar, Yashanad; Armour, Gary; Whitworth, Craig; Rybak, Leonard

    2003-03-01

    The role of apoptosis and proliferation in maintenance of cochlear lateral wall cells was examined. The methods employed for detection of apoptosis were the Hoechst fluorescence stain and TUNEL (TdT-mediated dUTP-biotin nick-end-labeling) assay, and proliferations were 5-bromo-2'-deoxyuridine (BrdU) incorporation and presence of the proliferating cell nuclear antigen. The incidence of apoptosis in the strial marginal cell was 50% greater (32.9+/-3.7%) than strial intermediate and basal cells but similar to spiral ligament cells. Although division of marginal strial cells was rarely detected, a significant number of proliferating cells in the remaining stria vascularis and spiral ligament were observed. These data implied that replacement of marginal cells arose elsewhere and could be followed by a BrdU-deoxythymidine pulse-chase study. At 2 h post injection, nuclear BrdU in marginal cells was not detected; however, by 24 h post injection, 20-25% of marginal cell nuclei were BrdU-positive. These observations are consistent with the hypothesis that marginal cells were replaced by underlying cells. Cell migration appears to be an important mechanism for preserving the function and structure of the stria vascularis.

  19. Cochlear implant users' spectral ripple resolution.

    Science.gov (United States)

    Jeon, Eun Kyung; Turner, Christopher W; Karsten, Sue A; Henry, Belinda A; Gantz, Bruce J

    2015-10-01

    This study revisits the issue of the spectral ripple resolution abilities of cochlear implant (CI) users. The spectral ripple resolution of recently implanted CI recipients (implanted during the last 10 years) were compared to those of CI recipients implanted 15 to 20 years ago, as well as those of normal-hearing and hearing-impaired listeners from previously published data from Henry, Turner, and Behrens [J. Acoust. Soc. Am. 118, 1111-1121 (2005)]. More recently, implanted CI recipients showed significantly better spectral ripple resolution. There is no significant difference in spectral ripple resolution for these recently implanted subjects compared to hearing-impaired (acoustic) listeners. The more recently implanted CI users had significantly better pre-operative speech perception than previously reported CI users. These better pre-operative speech perception scores in CI users from the current study may be related to better performance on the spectral ripple discrimination task; however, other possible factors such as improvements in internal and external devices cannot be excluded.

  20. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  1. Cochlear nucleus neuron analysis in individuals with presbycusis.

    Science.gov (United States)

    Hinojosa, Raul; Nelson, Erik G

    2011-12-01

    The aim of this study was to analyze the cochlear nucleus neuron population in individuals with normal hearing and presbycusis. Retrospective study of archival human temporal bone and brain stem tissues. Using strict inclusion criteria, the temporal bones and cochlear nuclei from six normal hearing individuals and four individuals with presbycusis were selected for analysis. The spiral ganglion cell population, the cochlear nucleus neuron population, and the cell body size of the neurons were quantified in these cases. A relationship was not observed between age and the spiral ganglion cell population in the normal hearing group. Presbycusis subjects exhibited a reduced spiral ganglion cell population. The mean cochlear nucleus neuron population was observed to be significantly higher in the presbycusis group (mean ± standard deviation: 114,170 ± 10,570) compared to the normal hearing group (91,470 ± 9,510) (P = .019). This difference was predominantly the result of greater multipolar and granule cell neuron populations. Only the fusiform neuron type exhibited a significantly different mean cell body cross-sectional area between the normal hearing group (242 ± 27) and the presbycusis group (300 ± 37) (P = .033). This investigation is the first time, to our knowledge, that the populations of the eight neuron types in the cochlear nucleus have been quantified in both normal hearing individuals and individuals with presbycusis. The data support the concept that presbycusis is not an effect of aging alone but instead may be a condition that predisposes one to hearing loss with advancing age and is characterized by a congenitally elevated cochlear nucleus neuron population. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  3. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  4. Staphylococcus lugdunensis: novel organism causing cochlear implant infection

    Directory of Open Access Journals (Sweden)

    Samina Bhumbra

    2014-06-01

    Full Text Available A majority of cochlear implant infections are caused by Staphylococcus aureus or Pseudomonas aeruginosa. Reported here is a pediatric patient with a cochlear implant infection caused by methicillin-resistant Staphylococcus lugdunensis, a coagulase-negative Staphylococcus that has only recently been determined to be clinically relevant (1988. Unlike other coagulase-negative Staphylococcus, it is more aggressive, carrying a greater potential for tissue destruction. In pediatrics, the organism is uncommon, poorly described, and generally pan-susceptible. Described herein is the presentation and management of this unusual organism in a pediatric setting.

  5. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  6. Diagnostic Devices for Isothermal Nucleic Acid Amplification

    Directory of Open Access Journals (Sweden)

    Chia-Chen Chang

    2012-06-01

    Full Text Available Since the development of the polymerase chain reaction (PCR technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.

  7. Diagnostic devices for isothermal nucleic acid amplification.

    Science.gov (United States)

    Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann

    2012-01-01

    Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.

  8. Diverse Roles of Axonemal Dyneins in Drosophila Auditory Neuron Function and Mechanical Amplification in Hearing.

    Science.gov (United States)

    Karak, Somdatta; Jacobs, Julie S; Kittelmann, Maike; Spalthoff, Christian; Katana, Radoslaw; Sivan-Loukianova, Elena; Schon, Michael A; Kernan, Maurice J; Eberl, Daniel F; Göpfert, Martin C

    2015-11-26

    Much like vertebrate hair cells, the chordotonal sensory neurons that mediate hearing in Drosophila are motile and amplify the mechanical input of the ear. Because the neurons bear mechanosensory primary cilia whose microtubule axonemes display dynein arms, we hypothesized that their motility is powered by dyneins. Here, we describe two axonemal dynein proteins that are required for Drosophila auditory neuron function, localize to their primary cilia, and differently contribute to mechanical amplification in hearing. Promoter fusions revealed that the two axonemal dynein genes Dmdnah3 (=CG17150) and Dmdnai2 (=CG6053) are expressed in chordotonal neurons, including the auditory ones in the fly's ear. Null alleles of both dyneins equally abolished electrical auditory neuron responses, yet whereas mutations in Dmdnah3 facilitated mechanical amplification, amplification was abolished by mutations in Dmdnai2. Epistasis analysis revealed that Dmdnah3 acts downstream of Nan-Iav channels in controlling the amplificatory gain. Dmdnai2, in addition to being required for amplification, was essential for outer dynein arms in auditory neuron cilia. This establishes diverse roles of axonemal dyneins in Drosophila auditory neuron function and links auditory neuron motility to primary cilia and axonemal dyneins. Mutant defects in sperm competition suggest that both dyneins also function in sperm motility.

  9. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    Science.gov (United States)

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  10. Privacy amplification for quantum key distribution

    International Nuclear Information System (INIS)

    Watanabe, Yodai

    2007-01-01

    This paper examines classical privacy amplification using a universal family of hash functions. In quantum key distribution, the adversary's measurement can wait until the choice of hash functions is announced, and so the adversary's information may depend on the choice. Therefore the existing result on classical privacy amplification, which assumes the independence of the choice from the other random variables, is not applicable to this case. This paper provides a security proof of privacy amplification which is valid even when the adversary's information may depend on the choice of hash functions. The compression rate of the proposed privacy amplification can be taken to be the same as that of the existing one with an exponentially small loss in secrecy of a final key. (fast track communication)

  11. Oscillations of the Outer Boundary of the Outer Radiation Belt During Sawtooth Oscillations

    Directory of Open Access Journals (Sweden)

    Jae-Hun Kim

    2006-09-01

    Full Text Available We report three sawtooth oscillation events observed at geosynchronous orbit where we find quasi-periodic (every 2-3 hours sudden flux increases followed by slow flux decreases at the energy levels of ˜50-400 keV. For these three sawtooth events, we have examined variations of the outer boundary of the outer radiation belt. In order to determine L values of the outer boundary, we have used data of relativistic electron flux observed by the SAMPEX satellite. We find that the outer boundary of the outer radiation belt oscillates periodically being consistent with sawtooth oscillation phases. Specifically, the outer boundary of the outer radiation belt expands (namely, the boundary L value increases following the sawtooth particle flux enhancement of each tooth, and then contracts (namely, the boundary L value decreases while the sawtooth flux decreases gradually until the next flux enhancement. On the other hand, it is repeatedly seen that the asymmetry of the magnetic field intensity between dayside and nightside decreases (increases due to the dipolarization (the stretching on the nightside as the sawtooth flux increases (decreases. This implies that the periodic magnetic field variations during the sawtooth oscillations are likely responsible for the expansion-contraction oscillations of the outer boundary of the outer radiation belt.

  12. Rolling circle amplification of metazoan mitochondrialgenomes

    Energy Technology Data Exchange (ETDEWEB)

    Simison, W. Brian; Lindberg, D.R.; Boore, J.L.

    2005-07-31

    Here we report the successful use of rolling circle amplification (RCA) for the amplification of complete metazoan mt genomes to make a product that is amenable to high-throughput genome sequencing techniques. The benefits of RCA over PCR are many and with further development and refinement of RCA, the sequencing of organellar genomics will require far less time and effort than current long PCR approaches.

  13. Multisensory Integration in Cochlear Implant Recipients.

    Science.gov (United States)

    Stevenson, Ryan A; Sheffield, Sterling W; Butera, Iliza M; Gifford, René H; Wallace, Mark T

    Speech perception is inherently a multisensory process involving integration of auditory and visual cues. Multisensory integration in cochlear implant (CI) recipients is a unique circumstance in that the integration occurs after auditory deprivation and the provision of hearing via the CI. Despite the clear importance of multisensory cues for perception, in general, and for speech intelligibility, specifically, the topic of multisensory perceptual benefits in CI users has only recently begun to emerge as an area of inquiry. We review the research that has been conducted on multisensory integration in CI users to date and suggest a number of areas needing further research. The overall pattern of results indicates that many CI recipients show at least some perceptual gain that can be attributable to multisensory integration. The extent of this gain, however, varies based on a number of factors, including age of implantation and specific task being assessed (e.g., stimulus detection, phoneme perception, word recognition). Although both children and adults with CIs obtain audiovisual benefits for phoneme, word, and sentence stimuli, neither group shows demonstrable gain for suprasegmental feature perception. Additionally, only early-implanted children and the highest performing adults obtain audiovisual integration benefits similar to individuals with normal hearing. Increasing age of implantation in children is associated with poorer gains resultant from audiovisual integration, suggesting a sensitive period in development for the brain networks that subserve these integrative functions, as well as length of auditory experience. This finding highlights the need for early detection of and intervention for hearing loss, not only in terms of auditory perception, but also in terms of the behavioral and perceptual benefits of audiovisual processing. Importantly, patterns of auditory, visual, and audiovisual responses suggest that underlying integrative processes may be

  14. Local Mechanisms for Loud Sound-Enhanced Aminoglycoside Entry into Outer Hair Cells

    Directory of Open Access Journals (Sweden)

    Hongzhe eLi

    2015-04-01

    Full Text Available Loud sound exposure exacerbates aminoglycoside ototoxicity, increasing the risk of permanent hearing loss and degrading the quality of life in affected individuals. We previously reported that loud sound exposure induces temporary threshold shifts (TTS and enhances uptake of aminoglycosides, like gentamicin, by cochlear outer hair cells (OHCs. Here, we explore mechanisms by which loud sound exposure and TTS could increase aminoglycoside uptake by OHCs that may underlie this form of ototoxic synergy.Mice were exposed to loud sound levels to induce TTS, and received fluorescently-tagged gentamicin (GTTR for 30 minutes prior to fixation. The degree of TTS was assessed by comparing auditory brainstem responses before and after loud sound exposure. The number of tip links, which gate the GTTR-permeant mechanoelectrical transducer (MET channels, was determined in OHC bundles, with or without exposure to loud sound, using scanning electron microscopy.We found wide-band noise (WBN levels that induce TTS also enhance OHC uptake of GTTR compared to OHCs in control cochleae. In cochlear regions with TTS, the increase in OHC uptake of GTTR was significantly greater than in adjacent pillar cells. In control mice, we identified stereociliary tip links at ~50% of potential positions in OHC bundles. However, the number of OHC tip links was significantly reduced in mice that received WBN at levels capable of inducing TTS.These data suggest that GTTR uptake by OHCs during TTS occurs by increased permeation of surviving, mechanically-gated MET channels, and/or non-MET aminoglycoside-permeant channels activated following loud sound exposure. Loss of tip links would hyperpolarize hair cells and potentially increase drug uptake via aminoglycoside-permeant channels expressed by hair cells. The effect of TTS on aminoglycoside-permeant channel kinetics will shed new light on the mechanisms of loud sound-enhanced aminoglycoside uptake, and consequently on ototoxic

  15. The Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School

    Directory of Open Access Journals (Sweden)

    Aliakbar Dashtelei

    2015-12-01

    Full Text Available Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to sixth grades of primary school and 30 children with normal hearing who were matched in age with cochlear implant group. All of children were between 6 to 11 years old. Children with cochlear implant had at least 1 to 2 years of implant experience and they were over 5 years when they receive implantation. Children with cochlear implant were selected from Special education centers in Tehran and children with normal hearing were recruited from primary schools in Tehran. The phonemic awareness skills were assessed in both groups. Results: The results showed that the Mean scores of phonemic awareness skills in cochlear implant children were significantly lower than children with normal hearing (P<.0001. Discussion: children with cochlear implant, despite Cochlear implantation prosthesis, had lower performance in phonemic awareness when compared with normal hearing children. Therefore, due to importance of phonemic awareness skills in learning of literacy skills, and defects of these skills in children with cochlear implant, these skills should be assessed carefully in children with cochlear implant and rehabilitative interventions should be considered.

  16. ATP-gamma-S shifts the operating point of outer hair cell transduction towards scala tympani.

    Science.gov (United States)

    Bobbin, Richard P; Salt, Alec N

    2005-07-01

    ATP receptor agonists and antagonists alter cochlear mechanics as measured by changes in distortion product otoacoustic emissions (DPOAE). Some of the effects on DPOAEs are consistent with the hypothesis that ATP affects mechano-electrical transduction and the operating point of the outer hair cells (OHCs). This hypothesis was tested by monitoring the effect of ATP-gamma-S on the operating point of the OHCs. Guinea pigs anesthetized with urethane and with sectioned middle ear muscles were used. The cochlear microphonic (CM) was recorded differentially (scala vestibuli referenced to scala tympani) across the basal turn before and after perfusion (20 min) of the perilymph compartment with artificial perilymph (AP) and ATP-gamma-S dissolved in AP. The operating point was derived from the cochlear microphonics (CM) recorded in response low frequency (200 Hz) tones at high level (106, 112 and 118 dB SPL). The analysis procedure used a Boltzmann function to simulate the CM waveform and the Boltzmann parameters were adjusted to best-fit the calculated waveform to the CM. Compared to the initial perfusion with AP, ATP-gamma-S (333 microM) enhanced peak clipping of the positive peak of the CM (that occurs during organ of Corti displacements towards scala tympani), which was in keeping with ATP-induced displacement of the transducer towards scala tympani. CM waveform analysis quantified the degree of displacement and showed that the changes were consistent with the stimulus being centered on a different region of the transducer curve. The change of operating point meant that the stimulus was applied to a region of the transducer curve where there was greater saturation of the output on excursions towards scala tympani and less saturation towards scala vestibuli. A significant degree of recovery of the operating point was observed after washing with AP. Dose response curves generated by perfusing ATP-gamma-S (333 microM) in a cumulative manner yielded an EC(50) of 19.8 micro

  17. Strategies for Working with Children with Cochlear Implants

    Science.gov (United States)

    Schraer-Joiner, Lyn; Prause-Weber, Manuela

    2009-01-01

    According to the National Institute on Deafness and Other Communication Disorders, 23,000 individuals in the United States, including 10,000 children, have a cochlear implant. This biomedical electronic device has been a breakthrough in the auditory rehabilitation of individuals diagnosed with severe or profound sensorineural hearing losses who…

  18. Cochlear implantation and change in quality of life

    DEFF Research Database (Denmark)

    Faber, Christian; Grøntved, Ågot Møller

    2000-01-01

    The aim of this study was to assess the benefits of cochlear implantation (CI) in adults and to evaluate the average implant usage per day. Ten profoundly deaf adults were implanted during the period April 1994 to September 1997. The patients answered questionnaires 1 year or more after receiving...

  19. The influence of cochlear implant electrode position on performance

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Verbist, B.M.; Muurling, T.J.; Frijns, J.H.M.

    2015-01-01

    To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics.

  20. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  1. Identification and Multiplicity of Double Vowels in Cochlear Implant Users

    Science.gov (United States)

    Kwon, Bomjun J.; Perry, Trevor T.

    2014-01-01

    Purpose: The present study examined cochlear implant (CI) users' perception of vowels presented concurrently (i.e., "double vowels") to further our understanding of auditory grouping in electric hearing. Method: Identification of double vowels and single vowels was measured with 10 CI subjects. Fundamental frequencies (F0s) of…

  2. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  3. Speech Recognition and Cognitive Skills in Bimodal Cochlear Implant Users

    Science.gov (United States)

    Hua, Håkan; Johansson, Björn; Magnusson, Lennart; Lyxell, Björn; Ellis, Rachel J.

    2017-01-01

    Purpose: To examine the relation between speech recognition and cognitive skills in bimodal cochlear implant (CI) and hearing aid users. Method: Seventeen bimodal CI users (28-74 years) were recruited to the study. Speech recognition tests were carried out in quiet and in noise. The cognitive tests employed included the Reading Span Test and the…

  4. Libyan cochlear implant programme: achievements, difficulties, and future goals

    Directory of Open Access Journals (Sweden)

    Samya El-Ogbi

    2011-05-01

    Full Text Available Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI 100 devices. Thirty-four (91.9% of these patients were children, whilst three (8.1% were adults. Combined, congenital hearing loss (56.8% and perinatal/neonatal (29.7% were the two main aetiological factors in children. Seventeen patients (45.9% had a positive family history of deafness. Sixteen patients (43.2% were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  5. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    Science.gov (United States)

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  6. Modulation of cochlear tuning by low-frequency sound

    NARCIS (Netherlands)

    Klis, J.F.L.; Prijs, V.F.; Latour, J.B.; Smoorenburg, G.F.

    1988-01-01

    An intense, low-frequency tone (about 30 Hz) modulates the sensitivity of the inner ear to high-frequency stimulation. This modulation is correlated with the displacement of the basilar membrane. The findings suggest that the modulation may also affect cochlear tuning. We have investigated

  7. The Acceptance of Background Noise in Adult Cochlear Implant Users

    Science.gov (United States)

    Plyler, Patrick N.; Bahng, Junghwa; von Hapsburg, Deborah

    2008-01-01

    Purpose: The purpose of this study was to determine (a) if acceptable noise levels (ANLs) are different in cochlear implant (CI) users than in listeners with normal hearing, (b) if ANLs are related to sentence reception thresholds in noise in CI users, and (c) if ANLs and subjective outcome measures are related in CI users. Method: ANLs and the…

  8. A software tool for analyzing multichannel cochlear implant signals.

    Science.gov (United States)

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  9. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  10. Predictors of Spoken Language Development Following Pediatric Cochlear Implantation

    NARCIS (Netherlands)

    Johan Frijns; prof. Dr. Louis Peeraer; van Wieringen; Ingeborg Dhooge; Vermeulen; Jan Brokx; Tinne Boons; Wouters

    2012-01-01

    Objectives: Although deaf children with cochlear implants (CIs) are able to develop good language skills, the large variability in outcomes remains a significant concern. The first aim of this study was to evaluate language skills in children with CIs to establish benchmarks. The second aim was to

  11. Imaging of acquired non-traumatic cochlear lesions: iconographic essay

    International Nuclear Information System (INIS)

    Garcia, Marcelo de Mattos; Gonzaga, Juliana Gontijo

    2006-01-01

    Different non-traumatic acquired cochlear lesions are shown in this article with imaging methods. They may be responsible for neuro sensorial hearing loss or vertigo. The method of choice is computed tomography when evaluating the osseous labyrinth whereas magnetic resonance imaging has superior resolution in the studies of the membranaceous labyrinth. (author)

  12. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  13. Theory of Mind and Language in Children with Cochlear Implants

    Science.gov (United States)

    Remmel, Ethan; Peters, Kimberly

    2009-01-01

    Thirty children with cochlear implants (CI children), age range 3-12 years, and 30 children with normal hearing (NH children), age range 4-6 years, were tested on theory of mind and language measures. The CI children showed little to no delay on either theory of mind, relative to the NH children, or spoken language, relative to hearing norms. The…

  14. Reading comprehension of deaf children with cochlear implants

    NARCIS (Netherlands)

    Vermeulen, A.M.; Bon, W.H.J. van; Schreuder, R.; Knoors, H.E.T.; Snik, A.F.M.

    2007-01-01

    The reading comprehension and visual word recognition in 50 deaf children and adolescents with at least 3 years of cochlear implant (0) use were evaluated. Their skills were contrasted with reference data of 500 deaf children without CIs. The reading comprehension level in children with CIs was

  15. The Relationship Between Cochlear Implants and Deaf Identity

    DEFF Research Database (Denmark)

    Chapman, Madeleine; Dammeyer, Jesper

    2017-01-01

    from a Danish national survey of deaf adults, the authors examined the significance of having (or not having) a CI in regard to identity (categorized as deaf, hearing, bicultural, and marginal) and various related factors concerning social participation and experiences of being deaf. Cochlear...

  16. Motor Development of Deaf Children with and without Cochlear Implants

    Science.gov (United States)

    Gheysen, Freja; Loots, Gerrit; Van Waelvelde, Hilde

    2008-01-01

    The purpose of this study was to investigate the impact of a cochlear implant (CI) on the motor development of deaf children. The study involved 36 mainstreamed deaf children (15 boys, 21 girls; 4- to 12-years old) without any developmental problems. Of these children, 20 had been implanted. Forty-three hearing children constituted a comparison…

  17. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  18. Mismatch Negativity Based Neurofeedback for Cochlear Implant Users

    NARCIS (Netherlands)

    Luckmann, Annika; Başkent, Deniz; Jolij, Jacob

    2015-01-01

    Cochlear implant (CI) users experience great difficulty when it comes to pitch discrimination. This leads to problems during daily interactions, due to poor speech perception, but also a very low pleasure ratings for music. Improving pitch perception and discrimination in CI users would improve

  19. Cochlear Damage Affects Neurotransmitter Chemistry in the Central Auditory System

    Directory of Open Access Journals (Sweden)

    Donald Albert Godfrey

    2014-11-01

    Full Text Available Tinnitus, the perception of a monotonous sound not actually present in the environment, affects nearly 20% of the population of the United States. Although there has been great progress in tinnitus research over the past 25 years, the neurochemical basis of tinnitus is still poorly understood. We review current research about the effects of various types of cochlear damage on the neurotransmitter chemistry in the central auditory system and document evidence that different changes in this chemistry can underlie similar behaviorally measured tinnitus symptoms. Most available data have been obtained from rodents following cochlear damage produced by cochlear ablation, loud sound, or ototoxic drugs. Effects on neurotransmitter systems have been measured as changes in neurotransmitter level, synthesis, release, uptake, and receptors. In this review, magnitudes of changes are presented for neurotransmitter-related amino acids, acetylcholine, and serotonin. A variety of effects have been found in these studies that may be related to animal model, survival time, type of cochlear damage, or methodology. The overall impression from the evidence presented is that any imbalance of neurotransmitter-related chemistry could disrupt auditory processing in such a way as to produce tinnitus.

  20. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  1. Classroom performance of children with cochlear implants in mainstream education.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Oever-Goltstein, M.H. van den; Langereis, M.C.; Chute, P.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: We compared classroom performance of children with a cochlear implant (CI) with that of their normal-hearing peers in mainstream education. METHODS: Thirty-two CI children in mainstream education, congenitally or prelingually deaf, participated in this study, as did 37 hearing

  2. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  3. Simultaneous Communication and Cochlear Implants in the Classroom?

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.

    2015-01-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users

  4. Simultaneous communication supports learning in noise by cochlear implant users

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.; Machmer, E.

    2017-01-01

    Objectives: This study sought to evaluate the potential of using spoken language and signing together (simultaneous communication, SimCom, sign-supported speech) as a means of improving speech recognition, comprehension, and learning by cochlear implant (CI) users in noisy contexts.Methods: Forty

  5. Perception of Cantonese Lexical Tones by Pediatric Cochlear Implant Users

    Science.gov (United States)

    Holt, Colleen M.; Lee, Kathy Y. S.; Dowell, Richard C.; Vogel, Adam P.

    2018-01-01

    Purpose: The purpose of this study is to assess Cantonese word recognition and the discrimination of Cantonese tones with manipulated contours by child and adolescent cochlear implant (CI) users and a group of peers with normal hearing (NH). It was hypothesized that the CI users would perform more poorly than their counterparts with NH in both…

  6. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  7. Effects of neuroactive steroids on cochlear hair cell death induced by gentamicin.

    Science.gov (United States)

    Nakamagoe, Mariko; Tabuchi, Keiji; Nishimura, Bungo; Hara, Akira

    2011-12-11

    As neuroactive steroids, sex steroid hormones have non-reproductive effects. We previously reported that 17β-estradiol (βE2) had protective effects against gentamicin (GM) ototoxicity in the cochlea. In the present study, we examined whether the protective action of βE2 on GM ototoxicity is mediated by the estrogen receptor (ER) and whether other estrogens (17α-estradiol (αE2), estrone (E1), and estriol (E3)) and other neuroactive steroids, dehydroepiandrosterone (DHEA) and progesterone (P), have similar protective effects. The basal turn of the organ of Corti was dissected from Sprague-Dawley rats and cultured in a medium containing 100 μM GM for 48h. The effects of βE2 and ICI 182,780, a selective ER antagonist, were examined. In addition, the effects of other estrogens, DHEA and P were tested using this culture system. Loss of outer hair cells induced by GM exposure was compared among groups. βE2 exhibited a protective effect against GM ototoxicity, but its protective effect was antagonized by ICI 182,780. αE2, E1, and E3 also protected hair cells against gentamicin ototoxicity. DHEA showed a protective effect; however, the addition of ICI 182,780 did not affect hair cell loss. P did not have any effect on GM-induced outer hair cell death. The present findings suggest that estrogens and DHEA are protective agents against GM ototoxicity. The results of the ER antagonist study also suggest that the protective action of βE2 is mediated via ER but that of DHEA is not related to its conversion to estrogen and binding to ER. Further studies on neuroactive steroids may lead to new insights regarding cochlear protection. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Evaluation of cochlear involvement by distortion product otoacoustic emission in Behçet's disease.

    Science.gov (United States)

    Dagli, Muharrem; Eryilmaz, Adil; Tanrikulu, Salih; Aydin, Acar; Gonul, Muzeyyen; Gul, Ulker; Gocer, Celil

    2008-09-01

    The aim of this study was to investigate cochlear involvement in patients with Behçet's disease. Twenty-six Behçet's disease patients (52 ears) and 24 sex and age-matched healthy control subjects (48 ears) were included in the study. Pure-tone audiometry at frequencies 250, 500, 1000, 2000, 4000, 6000 Hz, immittance measures including tympanometry and acoustic reflex testing and DPOAE (distortion product otoacoustic emission) testing were performed in the patients and controls. A sensorineural hearing loss was found in eight patients (30.7%) as it was bilateral in five and unilateral in three patients. Although no typical audiometric configuration was found, one patient had a flat type audiogram, and the others had a high frequency hearing loss. The DPOAE responses of the patients and controls were significantly different in all frequencies (p<0.05). These results indicate that cochlea is affected by damage of outer hair cells in Behçet's disease.

  9. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  10. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  11. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  12. Factors contributing to communication skills development in cochlear implanted children.

    Science.gov (United States)

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  13. Barriers to pediatric cochlear implantation: A parental survey.

    Science.gov (United States)

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  14. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    Science.gov (United States)

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  15. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  16. Outer planet probe cost estimates: First impressions

    Science.gov (United States)

    Niehoff, J.

    1974-01-01

    An examination was made of early estimates of outer planetary atmospheric probe cost by comparing the estimates with past planetary projects. Of particular interest is identification of project elements which are likely cost drivers for future probe missions. Data are divided into two parts: first, the description of a cost model developed by SAI for the Planetary Programs Office of NASA, and second, use of this model and its data base to evaluate estimates of probe costs. Several observations are offered in conclusion regarding the credibility of current estimates and specific areas of the outer planet probe concept most vulnerable to cost escalation.

  17. [Investigation of RNA viral genome amplification by multiple displacement amplification technique].

    Science.gov (United States)

    Pang, Zheng; Li, Jian-Dong; Li, Chuan; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    In order to facilitate the detection of newly emerging or rare viral infectious diseases, a negative-strand RNA virus-severe fever with thrombocytopenia syndrome bunyavirus, and a positive-strand RNA virus-dengue virus, were used to investigate RNA viral genome unspecific amplification by multiple displacement amplification technique from clinical samples. Series of 10-fold diluted purified viral RNA were utilized as analog samples with different pathogen loads, after a series of reactions were sequentially processed, single-strand cDNA, double-strand cDNA, double-strand cDNA treated with ligation without or with supplemental RNA were generated, then a Phi29 DNA polymerase depended isothermal amplification was employed, and finally the target gene copies were detected by real time PCR assays to evaluate the amplification efficiencies of various methods. The results showed that multiple displacement amplification effects of single-strand or double-strand cDNA templates were limited, while the fold increases of double-strand cDNA templates treated with ligation could be up to 6 X 10(3), even 2 X 10(5) when supplemental RNA existed, and better results were obtained when viral RNA loads were lower. A RNA viral genome amplification system using multiple displacement amplification technique was established in this study and effective amplification of RNA viral genome with low load was achieved, which could provide a tool to synthesize adequate viral genome for multiplex pathogens detection.

  18. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    Science.gov (United States)

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  19. Reactive neurogenesis and down-regulation of the potassium-chloride cotransporter KCC2 in the cochlear nuclei after cochlear deafferentation

    Directory of Open Access Journals (Sweden)

    Brahim Tighilet

    2016-08-01

    Full Text Available While many studies have been devoted to investigating the homeostatic plasticity triggered by cochlear hearing loss, the cellular and molecular mechanisms involved in these central changes remain elusive. In the present study, we investigated the possibility of reactive neurogenesis after unilateral cochlear nerve section in the cochlear nucleus of cats. We found a strong cell proliferation in all the cochlear nucleus sub-divisions ipsilateral to the lesion. Most of the newly generated cells survive up to one month after cochlear deafferentation in all cochlear nuclei (except the dorsal cochlear nucleus and give rise to a variety of cell types, i.e. microglial cells, astrocytes and neurons. Interestingly, many of the newborn neurons had an inhibitory (GABAergic phenotype. This result is intriguing since sensory deafferentation is usually accompanied by enhanced excitation, consistent with a reduction in central inhibition. The membrane potential effect of GABA depends, however, on the intra-cellular chloride concentration, which is maintained at low levels in adults by the potassium chloride co-transporter KCC2. The KCC2 density on the plasma membrane of neurons was then assessed after cochlear deafferentation in the cochlear nuclei ipsilateral and contralateral to the lesion. Cochlear deafferentation is accompanied by a strong down-regulation of KCC2 ipsilateral to the lesion at 3 and 30 days post-lesion. This study suggests that reactive neurogenesis and downregulation of KCC2 is part of the vast repertoire involved in homeostatic plasticity triggered by hearing loss. These central changes may also play a role in the generation of tinnitus and hyperacusis.

  20. 27 CFR 9.207 - Outer Coastal Plain.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Outer Coastal Plain. 9.207... Outer Coastal Plain. (a) Name. The name of the viticultural area described in this section is “Outer Coastal Plain”. For purposes of part 4 of this chapter, “Outer Coastal Plain” is a term of viticultural...

  1. Helicase-dependent amplification of nucleic acids.

    Science.gov (United States)

    Cao, Yun; Kim, Hyun-Jin; Li, Ying; Kong, Huimin; Lemieux, Bertrand

    2013-10-11

    Helicase-dependent amplification (HDA) is a novel method for the isothermal in vitro amplification of nucleic acids. The HDA reaction selectively amplifies a target sequence by extension of two oligonucleotide primers. Unlike the polymerase chain reaction (PCR), HDA uses a helicase enzyme to separate the deoxyribonucleic acid (DNA) strands, rather than heat denaturation. This allows DNA amplification without the need for thermal cycling. The helicase used in HDA is a helicase super family II protein obtained from a thermophilic organism, Thermoanaerobacter tengcongensis (TteUvrD). This thermostable helicase is capable of unwinding blunt-end nucleic acid substrates at elevated temperatures (60° to 65°C). The HDA reaction can also be coupled with reverse transcription for ribonucleic acid (RNA) amplification. The products of this reaction can be detected during the reaction using fluorescent probes when incubations are conducted in a fluorimeter. Alternatively, products can be detected after amplification using a disposable amplicon containment device that contains an embedded lateral flow strip. Copyright © 2013 John Wiley & Sons, Inc.

  2. STEREOLOGICAL ANALYSIS OF THE COCHLEAR NUCLEI OF MONKEY (MACACA FASCICULARIS AFTER DEAFFERENTATION

    Directory of Open Access Journals (Sweden)

    Ana M Insausti

    2011-05-01

    Full Text Available The cochlear nuclei (CN in the brainstem receive the input signals from the inner ear through the cochlear nerve, and transmit these signals to higher auditory centres. A variety of lesions of the cochlear nerve cause deafness. As reported in the literature, artificial removal of auditive input, or 'deafferentation', induces structural alterations in the CN. The purpose of this study was to estimate a number of relevant stereological parameters of the CN in control and deafferented Macaca fascicularis monkeys.

  3. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  4. Outer-2-independent domination in graphs

    Indian Academy of Sciences (India)

    independent dominating set of a graph is a set of vertices of such that every vertex of ()\\ has a neighbor in and the maximum vertex degree of the subgraph induced by ()\\ is at most one. The outer-2-independent domination ...

  5. Intershell correlations in photoionization of outer shells

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M.Ya. [The Racah Institute of Physics, The Hebrew University of Jerusalem, Jerusalem 91904 (Israel); A.F. Ioffe Physical-Technical Institute, St. Petersburg 194021 (Russian Federation); Chernysheva, L.V. [A.F. Ioffe Physical-Technical Institute, St. Petersburg 194021 (Russian Federation); Drukarev, E.G. [National Research Center “Kurchatov Institute”, Konstantinov Petersburg Nuclear Physics Institute, St. Petersburg 188300 (Russian Federation)

    2016-02-15

    We demonstrate that the cross sections for photoionization of the outer shells are noticeably modified at the photon energies close to the thresholds of ionization of the inner shells due to correlations with the latter. The correlations may lead to increase or to decrease of the cross sections just above the ionization thresholds.

  6. Outer-2-independent domination in graphs

    Indian Academy of Sciences (India)

    Outer-2-independent domination in graphs. MARCIN KRZYWKOWSKI1,2,∗, DOOST ALI MOJDEH3 and MARYEM RAOOFI4. 1Department of Pure and Applied Mathematics, University of Johannesburg,. Johannesburg, South Africa. 2Faculty of Electronics, Telecommunications and Informatics, Gdansk University.

  7. Intershell correlations in photoionization of outer shells

    International Nuclear Information System (INIS)

    Amusia, M.Ya.; Chernysheva, L.V.; Drukarev, E.G.

    2016-01-01

    We demonstrate that the cross sections for photoionization of the outer shells are noticeably modified at the photon energies close to the thresholds of ionization of the inner shells due to correlations with the latter. The correlations may lead to increase or to decrease of the cross sections just above the ionization thresholds.

  8. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  10. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  11. Noise-Induced Loss of Hair Cells and Cochlear Synaptopathy Are Mediated by the Activation of AMPK.

    Science.gov (United States)

    Hill, Kayla; Yuan, Hu; Wang, Xianren; Sha, Su-Hua

    2016-07-13

    Noise-induced hearing loss (NIHL) is a major unresolved public health problem. Here, we investigate pathomechanisms of sensory hair cell death and suggest a novel target for protective intervention. Cellular survival depends upon maintenance of energy homeostasis, largely by AMP-activated protein kinase (AMPK). In response to a noise exposure in CBA/J mice, the levels of phosphorylated AMPKα increased in hair cells in a noise intensity-dependent manner. Inhibition of AMPK via siRNA or the pharmacological inhibitor compound C attenuated noise-induced loss of outer hair cells (OHCs) and synaptic ribbons, and preserved auditory function. Additionally, noise exposure increased the activity of the upstream AMPK kinase liver kinase B1 (LKB1) in cochlear tissues. The inhibition of LKB1 by siRNA attenuated the noise-increased phosphorylation of AMPKα in OHCs, reduced the loss of inner hair cell synaptic ribbons and OHCs, and protected against NIHL. These results indicate that noise exposure induces hair cell death and synaptopathy by activating AMPK via LKB1-mediated pathways. Targeting these pathways may provide a novel route to prevent NIHL. Our results demonstrate for the first time that the activation of AMP-activated protein kinase (AMPK) α in sensory hair cells is noise intensity dependent and contributes to noise-induced hearing loss by mediating the loss of inner hair cell synaptic ribbons and outer hair cells. Noise induces the phosphorylation of AMPKα1 by liver kinase B1 (LKB1), triggered by changes in intracellular ATP levels. The inhibition of AMPK activation by silencing AMPK or LKB1, or with the pharmacological inhibitor compound C, reduced outer hair cell and synaptic ribbon loss as well as noise-induced hearing loss. This study provides new insights into mechanisms of noise-induced hearing loss and suggests novel interventions for the prevention of the loss of sensory hair cells and cochlear synaptopathy. Copyright © 2016 the authors 0270-6474/16/367497-14$15.00/0.

  12. Music perception and appraisal: cochlear implant users and simulated cochlear implant listening.

    Science.gov (United States)

    Wright, Rose; Uchanski, Rosalie M

    2012-05-01

    The inability to hear music well may contribute to decreased quality of life for cochlear implant (CI) users. Researchers have reported recently on the generally poor ability of CI users to perceive music, and a few researchers have reported on the enjoyment of music by CI users. However, the relation between music perception skills and music enjoyment is much less explored. Only one study has attempted to predict CI users' enjoyment and perception of music from the users' demographic variables and other perceptual skills (Gfeller et al, 2008). Gfeller's results yielded different predictive relationships for music perception and music enjoyment, and the relationships were weak, at best. The first goal of this study is to clarify the nature and relationship between music perception skills and musical enjoyment for CI users, by employing a battery of music tests. The second goal is to determine whether normal hearing (NH) subjects, listening with a CI simulation, can be used as a model to represent actual CI users for either music enjoyment ratings or music perception tasks. A prospective, cross-sectional observational study. Original music stimuli (unprocessed) were presented to CI users, and music stimuli processed with CI-simulation software were presented to 20 NH listeners (CIsim). As a control, original music stimuli were also presented to five other NH listeners. All listeners appraised 24 musical excerpts, performed music perception tests, and filled out a musical background questionnaire. Music perception tests were the Appreciation of Music in Cochlear Implantees (AMICI), Montreal Battery for Evaluation of Amusia (MBEA), Melodic Contour Identification (MCI), and University of Washington Clinical Assessment of Music Perception (UW-CAMP). Twenty-five NH adults (22-56 yr old), recruited from the local and research communities, participated in the study. Ten adult CI users (46-80 yr old), recruited from the patient population of the local adult cochlear implant

  13. ESTIMATION OF AMPLIFICATION FACTOR IN EARTHQUAKE ENGINEERING

    Directory of Open Access Journals (Sweden)

    Nazarov Yuriy Pavlovich

    2015-03-01

    Full Text Available The authors are the developers of Odyssey Software (Eurosoft Co. for the analysis of seismological data and computing of seismic loads and their parameters. While communicating with the users of the software, the authors have revealed some uncertainty about both understanding of the term "amplification factor (AF" and calculation of the amplification factor using various methods. In this article, a simple example shows that the determination of the amplification factor as the ratio of the acceleration’s spectrum to the maximal acceleration is derived from the classical definition of AF in the form of the ratio of maximal dynamic displacement to the displacement by the action of static load. Deterministic and probabilistic ap-proaches for the calculating of the AF were discussed. There was an example of AFs calculation and their envelopes for translational and rotational components of seismic impact by using Odyssey Software.

  14. Amplification of hofmeister effect by alcohols.

    Science.gov (United States)

    Xu, Yun; Liu, Guangming

    2014-07-03

    We have demonstrated that Hofmeister effect can be amplified by adding alcohols to aqueous solutions. The lower critical solution temperature behavior of poly(N-isopropylacrylamide) has been employed as the model system to study the amplification of Hofmeister effect. The alcohols can more effectively amplify the Hofmeister effect following the series methanol alcohols and following the series d-sorbitol ≈ xylitol ≈ meso-erythritol alcohols. Our study reveals that the relative extent of amplification of Hofmeister effect is determined by the stability of the water/alcohol complex, which is strongly dependent on the chemical structure of alcohols. The more stable solvent complex formed via stronger hydrogen bonds can more effectively differentiate the anions through the anion-solvent complex interactions, resulting in a stronger amplification of Hofmeister effect. This study provides an alternative method to tune the relative strength of Hofmeister effect besides salt concentration.

  15. Lidar using the backscatter amplification effect

    Science.gov (United States)

    Razenkov, Igor A.; Banakh, Victor A.

    2018-04-01

    Experimental data proving the possibility of lidar measurement of the refractive turbulence strength based on the effect of backscatter amplification (BSA) are reported. It is shown that the values of the amplification factor correlate with the variance of random jitter of optical image of an incoherent light source depending on the value of the structure constant of the air refractive index turbulent fluctuations averaged over the probing path. This paper presents the results of measurements of the BSA factor in comparison with the simultaneous measurements of the BSA peak, which is very narrow and only occurs on the laser beam axis. It is constructed the range-time images of the derivative of the amplification factor gives a comprehensive picture of the location of turbulent zones and their temporal dynamics.

  16. Turbulent amplification of magnetic fields in laboratory laser-produced shock waves

    International Nuclear Information System (INIS)

    Meinecke, J.; Doyle, H.W.; Bell, A.R.; Schekochihin, A.A.; Miniati, F.; Bingham, R.; Koenig, M.; Pelka, A.; Ravasio, A.; Yurchak, R.

    2014-01-01

    X-ray and radio observations of the supernova remnant Cassiopeia A reveal the presence of magnetic fields about 100 times stronger than those in the surrounding interstellar medium. Field coincident with the outer shock probably arises through a nonlinear feedback process involving cosmic rays. The origin of the large magnetic field in the interior of the remnant is less clear but it is presumably stretched and amplified by turbulent motions. Turbulence may be generated by hydrodynamic instability at the contact discontinuity between the supernova ejecta and the circumstellar gas. However, optical observations of Cassiopeia A indicate that the ejecta are interacting with a highly inhomogeneous, dense circumstellar cloud bank formed before the supernova explosion. Here we investigate the possibility that turbulent amplification is induced when the outer shock overtakes dense clumps in the ambient medium. We report laboratory experiments that indicate the magnetic field is amplified when the shock interacts with a plastic grid. We show that our experimental results can explain the observed synchrotron emission in the interior of the remnant. The experiment also provides a laboratory example of magnetic field amplification by turbulence in plasmas, a physical process thought to occur in many astrophysical phenomena. (authors)

  17. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation

    DEFF Research Database (Denmark)

    Mangado Lopez, Nerea; Ceresa, Mario; Duchateau, Nicolas

    2016-01-01

    . To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient......'s CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns......Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging...

  18. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  19. Piezoelectric materials mimic the function of the cochlear sensory epithelium.

    Science.gov (United States)

    Inaoka, Takatoshi; Shintaku, Hirofumi; Nakagawa, Takayuki; Kawano, Satoyuki; Ogita, Hideaki; Sakamoto, Tatsunori; Hamanishi, Shinji; Wada, Hiroshi; Ito, Juichi

    2011-11-08

    Cochlear hair cells convert sound vibration into electrical potential, and loss of these cells diminishes auditory function. In response to mechanical stimuli, piezoelectric materials generate electricity, suggesting that they could be used in place of hair cells to create an artificial cochlear epithelium. Here, we report that a piezoelectric membrane generated electrical potentials in response to sound stimuli that were able to induce auditory brainstem responses in deafened guinea pigs, indicating its capacity to mimic basilar membrane function. In addition, sound stimuli were transmitted through the external auditory canal to a piezoelectric membrane implanted in the cochlea, inducing it to vibrate. The application of sound to the middle ear ossicle induced voltage output from the implanted piezoelectric membrane. These findings establish the fundamental principles for the development of hearing devices using piezoelectric materials, although there are many problems to be overcome before practical application.

  20. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  1. Acute Zonal Cone Photoreceptor Outer Segment Loss.

    Science.gov (United States)

    Aleman, Tomas S; Sandhu, Harpal S; Serrano, Leona W; Traband, Anastasia; Lau, Marisa K; Adamus, Grazyna; Avery, Robert A

    2017-05-01

    The diagnostic path presented narrows down the cause of acute vision loss to the cone photoreceptor outer segment and will refocus the search for the cause of similar currently idiopathic conditions. To describe the structural and functional associations found in a patient with acute zonal occult photoreceptor loss. A case report of an adolescent boy with acute visual field loss despite a normal fundus examination performed at a university teaching hospital. Results of a complete ophthalmic examination, full-field flash electroretinography (ERG) and multifocal ERG, light-adapted achromatic and 2-color dark-adapted perimetry, and microperimetry. Imaging was performed with spectral-domain optical coherence tomography (SD-OCT), near-infrared (NIR) and short-wavelength (SW) fundus autofluorescence (FAF), and NIR reflectance (REF). The patient was evaluated within a week of the onset of a scotoma in the nasal field of his left eye. Visual acuity was 20/20 OU, and color vision was normal in both eyes. Results of the fundus examination and of SW-FAF and NIR-FAF imaging were normal in both eyes, whereas NIR-REF imaging showed a region of hyporeflectance temporal to the fovea that corresponded with a dense relative scotoma noted on light-adapted static perimetry in the left eye. Loss in the photoreceptor outer segment detected by SD-OCT co-localized with an area of dense cone dysfunction detected on light-adapted perimetry and multifocal ERG but with near-normal rod-mediated vision according to results of 2-color dark-adapted perimetry. Full-field flash ERG findings were normal in both eyes. The outer nuclear layer and inner retinal thicknesses were normal. Localized, isolated cone dysfunction may represent the earliest photoreceptor abnormality or a distinct entity within the acute zonal occult outer retinopathy complex. Acute zonal occult outer retinopathy should be considered in patients with acute vision loss and abnormalities on NIR-REF imaging, especially if

  2. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  3. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  4. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  5. Cochlear implantation in children and adults in Switzerland

    OpenAIRE

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H. J.

    2014-01-01

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has...

  6. Concept Formation Skills in Long-Term Cochlear Implant Users

    OpenAIRE

    Castellanos, Irina; Kronenberger, William G.; Beer, Jessica; Colson, Bethany G.; Henning, Shirley C.; Ditmars, Allison; Pisoni, David B.

    2014-01-01

    This study investigated if a period of auditory sensory deprivation followed by degraded auditory input and related language delays affects visual concept formation skills in long-term prelingually deaf cochlear implant (CI) users. We also examined if concept formation skills are mediated or moderated by other neurocognitive domains (i.e., language, working memory, and executive control). Relative to normally hearing (NH) peers, CI users displayed significantly poorer performance in several s...

  7. Prevalence of Contralateral Hearing Aid Use in Adults with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Yamaguchi, Cintia Tizue

    2013-09-01

    Full Text Available Introduction: The exclusive use of a cochlear implant (CI in one ear allows patients to effectively hear speech in a quiet environment. However, in environments with competing noise, the processing of multiple sounds becomes complex. In an attempt to promote binaural hearing in a noninvasive manner, the use of a hearing aid in the nonimplanted ear is suggested for patients with a unilateral CI. Aims: To identify the prevalence of hearing aid use in the contralateral ear in adults who already have a CI; to determine the reasons why some patients do not use contralateral hearing aids (CHAs; and to analyze the effects of residual hearing in CHA users. Materials and Methods: This is a clinical study in 82 adult patients with CI implants who responded to a questionnaire designed to determine current use of CHA. Results: In our patient sample, 70 CHA nonusers were identified. The prevalence of CHA users was determined to be 12% with a 95% confidence interval of 11 to 13%. About 58.2% of the CHA nonusers reported a lack of noticeable benefit even after wearing hearing aids, and 23.6% reported not having received the option to use a CHA. CHA users had a pure tone average of 107-dB hearing level, whereas CHA nonusers had a pure tone average of 117-dB hearing level. Conclusion: The prevalence of the use of a CHA is low in our study. We attribute the low use of a CHA to either a lack of residual hearing or to a lack of benefit from the amplification.

  8. Rapid detection of microbial DNA by a novel isothermal genome exponential amplification reaction (GEAR) assay.

    Science.gov (United States)

    Prithiviraj, Jothikumar; Hill, Vincent; Jothikumar, Narayanan

    2012-04-20

    In this study we report the development of a simple target-specific isothermal nucleic acid amplification technique, termed genome exponential amplification reaction (GEAR). Escherichia coli was selected as the microbial target to demonstrate the GEAR technique as a proof of concept. The GEAR technique uses a set of four primers; in the present study these primers targeted 5 regions on the 16S rRNA gene of E. coli. The outer forward and reverse Tab primer sequences are complementary to each other at their 5' end, whereas their 3' end sequences are complementary to their respective target nucleic acid sequences. The GEAR assay was performed at a constant temperature 60 °C and monitored continuously in a real-time PCR instrument in the presence of an intercalating dye (SYTO 9). The GEAR assay enabled amplification of as few as one colony forming units of E. coli per reaction within 30 min. We also evaluated the GEAR assay for rapid identification of bacterial colonies cultured on agar media directly in the reaction without DNA extraction. Cells from E. coli colonies were picked and added directly to GEAR assay mastermix without prior DNA extraction. DNA in the cells could be amplified, yielding positive results within 15 min. Published by Elsevier Inc.

  9. Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Fagertun, Jens; Vera, Sergio

    2016-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Proper non-rigid alignment of high-resolution cochlear μCT data is a challenge for the typical cubic B-spline registration model. In this paper we study one way ...

  10. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  11. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    Science.gov (United States)

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  12. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  13. Development of micro-electromechanical system (MEMS) cochlear biomodel

    Energy Technology Data Exchange (ETDEWEB)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira [Faculty of Electronic and Computer Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  14. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  15. Development of micro-electromechanical system (MEMS) cochlear biomodel

    International Nuclear Information System (INIS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-01-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane

  16. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  17. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  18. Amplification in Technical Manuals: Theory and Practice.

    Science.gov (United States)

    Killingsworth, M. Jimmie; And Others

    1989-01-01

    Examines how amplification (rhetorical techniques by which discourse is extended to enhance its appeal and information value) tends to increase and improve the coverage, rationale, warnings, behavioral alternatives, examples, previews, and general emphasis of technical manuals. Shows how classical and modern rhetorical theories can be applied to…

  19. Intelligence amplification framework for enhancing scheduling processes

    NARCIS (Netherlands)

    Dobrkovic, Andrej; Liu, Luyao; Iacob, Maria Eugenia; van Hillegersberg, Jos

    2016-01-01

    The scheduling process in a typical business environment consists of predominantly repetitive tasks that have to be completed in limited time and often containing some form of uncertainty. The intelligence amplification is a symbiotic relationship between a human and an intelligent agent. This

  20. Social amplification of risk: a conceptual framework

    International Nuclear Information System (INIS)

    Kasperson, R.E.; Renn, O.; Slovic, P.; Brown, H.S.; Emel, J.; Goble, R.; Kasperson, J.X.; Ratick, S.

    1988-01-01

    One of the most perplexing problems in risk analysis is why some relatively minor risks or risk events, as assessed by technical experts, often elicit strong public concerns and result in substantial impacts upon society and economy. This article sets forth a conceptual framework that seeks to link systematically the technical assessment of risk with psychological, sociological, and cultural perspectives of risk perception and risk-related behavior. The main thesis is that hazards interact with psychological, social, institutional, and cultural processes in ways that may amplify or attenuate public responses to the risk or risk event. A structural description of the social amplification of risk is now possible. Amplification occurs at two stages: in the transfer of information about the risk, and in the response mechanisms of society. Signals about risk are processed by individual and social amplification stations, including the scientist who communicates the risk assessment, the news media, cultural groups, interpersonal networks, and others. Key steps of amplifications can be identified at each stage. The amplified risk leads to behavioral responses, which, in turn, result in secondary impacts. Models are presented that portray the elements and linkages in the proposed conceptual framework

  1. Performance of the LHCb Outer Tracker

    CERN Document Server

    Arink, R; Bachmann, S.; Bagaturia, Y.; Band, H.; Bauer, Th.; Berkien, A.; Farber, Ch.; Bien, A.; Blouw, J.; Ceelie, L.; Coco, V.; Deckenhoff, M.; Deng, Z.; Dettori, F.; van Eijk, D.; Ekelhof, R.; Gersabeck, E.; Grillo, L.; Hulsbergen, W.D.; Karbach, T.M.; Koopman, R.; Kozlinskiy, A.; Langenbruch, Ch.; Lavrentyev, V.; Linn, Ch.; Merk, M.; Merkel, J.; Meissner, M.; Michalowski, J.; Morawski, P.; Nawrot, A.; Nedos, M.; Pellegrino, A.; Polok, G.; van Petten, O.; Rovekamp, J.; Schimmel, F.; Schuylenburg, H.; Schwemmer, R.; Seyfert, P.; Serra, N.; Sluijk, T.; Spaan, B.; Spelt, J.; Storaci, B.; Szczekowski, M.; Swientek, S.; Tolk, S.; Tuning, N.; Uwer, U.; Wiedner, D.; Witek, M.; Zeng, M.; Zwart, A.

    2014-01-01

    The LHCb Outer Tracker is a gaseous detector covering an area of 5x6 m2 with 12 double layers of straw tubes. The detector with its services are described together with the commissioning and calibration procedures. Based on data of the first LHC running period from 2010 to 2012, the performance of the readout electronics and the single hit resolution and efficiency are presented. The efficiency to detect a hit in the central half of the straw is estimated to be 99.2%, and the position resolution is determined to be approximately 200 um. The Outer Tracker received a dose in the hottest region corresponding to 0.12 C/cm, and no signs of gain deterioration or other ageing effects are observed.

  2. The Outer Space as an Educational Motivation

    Science.gov (United States)

    Pérez-Pérez, Melquíades; Hernández-López, Montserrat

    2017-06-01

    STEAM is an educational approach to learning that uses Science, Technology, Engineering, the Arts and Mathematics as access points for guiding student inquiry, dialogue, and critical thinking. The end results are students who take thoughtful risks, engage in experiential learning, persist in problem-solving, embrace collaboration, and work through the creative process. The Outer Space is a window to the past and the future of our travel around the history of the Universe and can be used as a educational tool in primary and secondary education. This paper talks about the integration of the resources of European Space Agency, Space Awareness, Nuclio, Scientix and Schoolnet as motivation to integrate STEAM methodology in secondary education. Keywords: STEAM, outer space, motivation, methodology

  3. The Outer Banks of North Carolina

    Science.gov (United States)

    Dolan, Robert; Lins, Harry F.; Smith, Jodi Jones

    2016-12-27

    The Outer Banks of North Carolina are excellent examples of the nearly 300 barrier islands rimming the Atlantic and Gulf coasts of the United States. These low, sandy islands are among the most dynamic natural landscapes occupied by man. Beach sands move offshore, onshore, and along the shore in the direction of the prevailing longshore currents. In this way, sandy coasts continuously adjust to different tide, wave, and current conditions and to rising sea level that causes the islands to migrate landward.Despite such changes, barrier islands are of considerable environmental importance. The Outer Banks are home to diverse natural ecosystems that are adapted to the harsh coastal environment. Native species tend to be robust and many are specifically adapted to withstand salt spray, periodic saltwater flooding, and the islands’ well-drained sandy soil. The Outer Banks provide an important stopover for birds on the Atlantic flyway, and many species inhabit the islands year round. In addition, Outer Banks beaches provide an important nesting habitat for five endangered or threatened sea turtle species.European explorers discovered North Carolina’s barrier islands in the 16th century, although the islands were not permanently settled until the middle 17th century. By the early 19th century, shipbuilding and lumber industries were among the most successful, until forest resources were depleted. Commercial fishing eventually followed, and it expanded considerably after the Civil War. By the Great Depression, however, little industry existed on the Outer Banks. In response to the effects of a severe hurricane in 1933, the National Park Service and the Civilian Conservation Corps proposed a massive sand-fixation program to stabilize the moving sand and prevent storm waves from sweeping across the entire width of some sections of the islands. Between 1933 and 1940, this program constructed sand fencing on 185 kilometers (115 miles) of beach and planted grass seedlings

  4. Cryovolcanism in the outer solar system

    Science.gov (United States)

    Geissler, Paul E.

    2015-01-01

    Cryovolcanism is defined as the extrusion of liquids and vapors of materials that would be frozen solid at the planetary surface temperatures of the icy bodies of the outer solar system. Active cryovolcanism is now known to occur on Saturn's moon Enceladus and on Neptune's moon Triton and is suspected on Jupiter's moon Europa, while evidence for past cryovolcanic activity is widespread throughout the outer solar system. This chapter examines the mechanisms and manifestations of cryovolcanism, beginning with a review of the materials that make up these unusual ‘‘magmas’’ and the means by which they might erupt and concluding with a volcanologist's tour of the farthest reaches of the solar system.

  5. Protection of nuclear facilities against outer aggressions

    International Nuclear Information System (INIS)

    Aussourd, P.; Candes, P.; Le Quinio, R.

    1976-01-01

    The various types of outer aggressions envisaged in safety analysis for nuclear facilities are reviewed. These outer aggressions are classified as natural and non-natural phenomena, the latter depending on the human activities in the vicinity of nuclear sites. The principal natural phenomena able to constitute aggressions are atmospheric phenomena (strong winds, snow storms, hail, frosting mists), hydrologie phenomena such as tides, surges, flood, low waters, and geologic phenomena such as earthquakes. Artificial phenomena are concerned with aircraft crashes, projectiles, fire, possible ruptures of dams, and intentional human aggressions. The protection against intentional human aggressions is of two sorts: first, the possibility of access to the installations mostly sensitive to sabotage are to be prevented or reduced, secondly redundant circuits and functions must be separated for preventing their simultaneous destruction in the case when sabotage actors have reach the core of the facility [fr

  6. Outer crust of nonaccreting cold neutron stars

    International Nuclear Information System (INIS)

    Ruester, Stefan B.; Hempel, Matthias; Schaffner-Bielich, Juergen

    2006-01-01

    The properties of the outer crust of nonaccreting cold neutron stars are studied by using modern nuclear data and theoretical mass tables, updating in particular the classic work of Baym, Pethick, and Sutherland. Experimental data from the atomic mass table from Audi, Wapstra, and Thibault of 2003 are used and a thorough comparison of many modern theoretical nuclear models, both relativistic and nonrelativistic, is performed for the first time. In addition, the influences of pairing and deformation are investigated. State-of-the-art theoretical nuclear mass tables are compared to check their differences concerning the neutron drip line, magic neutron numbers, the equation of state, and the sequence of neutron-rich nuclei up to the drip line in the outer crust of nonaccreting cold neutron stars

  7. Boundary layers of the earth's outer magnetosphere

    Science.gov (United States)

    Eastman, T. E.; Frank, L. A.

    1984-01-01

    The magnetospheric boundary layer and the plasma-sheet boundary layer are the primary boundary layers of the earth's outer magnetosphere. Recent satellite observations indicate that they provide for more than 50 percent of the plasma and energy transport in the outer magnetosphere although they constitute less than 5 percent by volume. Relative to the energy density in the source regions, plasma in the magnetospheric boundary layer is predominantly deenergized whereas plasma in the plasma-sheet boundary layer has been accelerated. The reconnection hypothesis continues to provide a useful framework for comparing data sampled in the highly dynamic magnetospheric environment. Observations of 'flux transfer events' and other detailed features near the boundaries have been recently interpreted in terms of nonsteady-state reconnection. Alternative hypotheses are also being investigated. More work needs to be done, both in theory and observation, to determine whether reconnection actually occurs in the magnetosphere and, if so, whether it is important for overall magnetospheric dynamics.

  8. Boundary layers of the earth's outer magnetosphere

    International Nuclear Information System (INIS)

    Eastman, T.E.; Frank, L.A.

    1984-01-01

    The magnetospheric boundary layer and the plasma-sheet boundary layer are the primary boundary layers of the earth's outer magnetosphere. Recent satellite observations indicate that they provide for more than 50 percent of the plasma and energy transport in the outer magnetosphere although they constitute less than 5 percent by volume. Relative to the energy density in the source regions, plasma in the magnetospheric boundary layer is predominantly deenergized whereas plasma in the plasma-sheet boundary layer has been accelerated. The reconnection hypothesis continues to provide a useful framework for comparing data sampled in the highly dynamic magnetospheric environment. Observations of flux transfer events and other detailed features near the boundaries have been recently interpreted in terms of nonsteady-state reconnection. Alternative hypotheses are also being investigated. More work needs to be done, both in theory and observation, to determine whether reconnection actually occurs in the magnetosphere and, if so, whether it is important for overall magnetospheric dynamics. 30 references

  9. Differential Rotation within the Earth's Outer Core

    Science.gov (United States)

    Hide, R.; Boggs, D. H.; Dickey, J. O.

    1998-01-01

    Non-steady differential rotation drive by bouyancy forces within the Earth's liquid outer core (OC) plays a key role not only in the generation of the main geomagnetic field by the magnetohydrodynamic (MHD) dynamo process but also in the excitation of irregular fluctuations in the angular speed of rotation of the overlying solid mantle, as evidenced by changes in the length of the day (LOD) on decadal and longer timescales (1-8).

  10. Fluxgate magnetometers for outer planets exploration

    Science.gov (United States)

    Acuna, M. H.

    1974-01-01

    The exploration of the interplanetary medium and the magnetospheres of the outer planets requires the implementation of magnetic field measuring instrumentation with wide dynamic range, high stability, and reliability. The fluxgate magnetometers developed for the Pioneer 11 and Mariner-Jupiter-Saturn missions are presented. These instruments cover the range of .01 nT to 2 million nT with optimum performance characteristics and low power consumption.

  11. Outer Limits of Biotechnologies: A Jewish Perspective

    Directory of Open Access Journals (Sweden)

    John D. Loike

    2018-01-01

    Full Text Available A great deal of biomedical research focuses on new biotechnologies such as gene editing, stem cell biology, and reproductive medicine, which have created a scientific revolution. While the potential medical benefits of this research may be far-reaching, ethical issues related to non-medical applications of these technologies are demanding. We analyze, from a Jewish legal perspective, some of the ethical conundrums that society faces in pushing the outer limits in researching these new biotechnologies.

  12. Aspects of Music with Cochlear Implants – Music Listening Habits and Appreciation in Danish Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hansen, Mads; Sørensen, Stine Derdau

    Cochlear implant users differ significantly from their normal hearing peers when it comes to perception of music. Several studies have shown that structural features – such as rhythm, timbre, and pitch – are transmitted less accurately through an implant. However, we cannot predict personal...... music less post-implantation than prior to their hearing loss. Nevertheless, a large majority of CI listeners either prefer music over not hearing music at all or find music as pleasant as they recall it before their hearing loss, or more so....... enjoyment of music solely as a function of accuracy of perception. But can music be pleasant with a cochlear implant at all? Our aim here was to gather information of both music enjoyment and listening habits before the onset of hearing loss and post-operation from a large, representative sample of Danish...

  13. Evaluation of temporal bone pneumatization on high resolution CT (HRCT) measurements of the temporal bone in normal and otitis media group and their correlation to measurements of internal auditory meatus, vestibular or cochlear aqueduct

    International Nuclear Information System (INIS)

    Nakamura, Miyako

    1988-01-01

    High resolution CT axial scans were made at the three levels of the temoral bone 91 cases. These cases consisted of 109 sides of normal pneumatization (NR group) and 73 of poor pneumatization resulted by chronic otitis (OM group). NR group included sensorineural hearing loss cases and/or sudden deafness on the side. Three levels of continuous slicing were chosen at the internal auditory meatus, the vestibular and the cochlear aqueduct, respectively. In each slice two sagittal and two horizontal measurements were done on the outer contour of the temporal bone. At the proper level, diameter as well as length of the internal acoustic meatus, the vestibular or the cochlear aqueduct were measured. Measurements of the temporal bone showed statistically significant difference between NR and OM groups. Correlation of both diameter and length of the internal auditory meatus to the temporal bone measurements were statistically significant. Neither of measurements on the vestibular or the cochlear aqueduct showed any significant correlation to that of the temporal bone. (author)

  14. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    Science.gov (United States)

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  15. Effect of outer hair cell piezoelectricity on high-frequency receptor potentials.

    Science.gov (United States)

    Spector, Alexander A; Brownell, William E; Popel, Aleksander S

    2003-01-01

    The low-pass voltage response of outer hair cells predicted by conventional equivalent circuit analysis would preclude the active force production at high frequencies. We have found that the band pass characteristics can be improved by introducing the piezoelectric properties of the cell wall. In contrast to the conventional analysis, the receptor potential does not tend to zero and at any frequency is greater than a limiting value. In addition, the phase shift between the transduction current and receptor potential tends to zero. The piezoelectric properties cause an additional, strain-dependent, displacement current in the cell wall. The wall strain is estimated on the basis of a model of the cell deformation in the organ of Corti. The limiting value of the receptor potential depends on the ratio of a parameter determined by the piezoelectric coefficients and the strain to the membrane capacitance. In short cells, we have found that for the low-frequency value of about 2-3 mV and the strain level of 0.1% the receptor potential can reach 0.4 mV throughout the whole frequency range. In long cells, we have found that the effect of the piezoelectric properties is much weaker. These results are consistent with major features of the cochlear amplifier.

  16. Effect of inner and outer hair cell lesions on electrically evoked otoacoustic emissions.

    Science.gov (United States)

    Reyes, S; Ding, D; Sun, W; Salvi, R

    2001-08-01

    When the cochlea is stimulated by a sinusoidal current, the inner ear emits an acoustic signal at the stimulus frequency, termed the electrically evoked otoacoustic emission (EEOAE). Recent studies have found EEOAEs in birds lacking outer hair cells (OHCs), raising the possibility that other types of hair cells, including inner hair cells (IHCs), may generate EEOAEs. To determine the relative contribution of IHCs and OHCs to the generation of the EEOAE, we measured the amplitude of EEOAEs, distortion product otoacoustic emissions (DPOAEs), the cochlear microphonic (CM) and the compound action potential (CAP) in normal chinchillas and chinchillas with IHC lesions or IHC plus OHC lesions induced by carboplatin. Selective IHC loss had little or no effect on CM amplitude and caused a slight reduction in mean DPOAE amplitude. However, IHC loss resulted in a massive reduction in CAP amplitude. Importantly, selective IHC lesions did not reduce EEOAE amplitude, but instead, EEOAE amplitude increased at high frequencies. When both IHCs and OHCs were destroyed, the amplitude of the CM, DPOAE and EEOAE all decreased. The increase in EEOAE amplitude seen with IHC loss may be due to (1) loss of tonic efferent activity to the OHCs, (2) change in the mechanical properties of the cochlea or (3) elimination of EEOAEs produced by IHCs in phase opposition to those from OHCs.

  17. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  18. Parental mode of communication is essential for speech and language outcomes in cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, Lone; Cayé-Thomasen, Per; Breinegaard, Nina

    2010-01-01

    The present study demonstrates a very strong effect of the parental communication mode on the auditory capabilities and speech/language outcome for cochlear implanted children. The children exposed to spoken language had higher odds of scoring high in all tests applied and the findings suggest...... a very clear benefit of spoken language communication with a cochlear implanted child....

  19. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    Science.gov (United States)

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  20. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    Science.gov (United States)

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Spelling in Written Stories by School-Age Children with Cochlear Implants

    Science.gov (United States)

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  2. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    NARCIS (Netherlands)

    Sparreboom, M.; Leeuw, A.R.; Snik, A.F.M.; Mylanus, E.A.M.

    2012-01-01

    OBJECTIVE: The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral

  3. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  4. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  5. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    Science.gov (United States)

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  6. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  7. Identification of intracellular phospholipases A2 in the human eye: involvement in phagocytosis of photoreceptor outer segments

    DEFF Research Database (Denmark)

    Kolko, Miriam; Wang, Jinmei; Zhan, Chen

    2007-01-01

    PURPOSE: To identify intracellular phospholipases A(2) (PLA(2)) in the human retina and to explore the role of these enzymes in human retinal pigment epithelium (RPE) phagocytosis of photoreceptor outer segments (POS). METHODS: PCR amplification and Western blot analysis were used to identify m......)-VIA activity was found to be specifically increased 12 hours after ARPE-19 cells were fed with POS. Finally, RPE phagocytosis was inhibited by the iPLA(2)-VIA inhibitor bromoenol lactone. CONCLUSIONS: Various intracellular PLA(2) subtypes are present in the human retina. iPLA(2)-VIA may play...

  8. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  9. 75 FR 1076 - Outer Continental Shelf Civil Penalties

    Science.gov (United States)

    2010-01-08

    ... initiate civil penalty proceedings; however, violations that cause injury, death, or environmental damage... DEPARTMENT OF THE INTERIOR Minerals Management Service Outer Continental Shelf Civil Penalties... daily civil penalty assessment. SUMMARY: The Outer Continental Shelf Lands Act requires the MMS to...

  10. Comparison of the Soil Dynamic Amplification Factor and Soil Amplification by Using Microtremor and MASW Methods Respectively

    Science.gov (United States)

    Tuncel, Aykut; Cevdet Özdag, Özkan; Pamuk, Eren; Akgün, Mustafa

    2017-12-01

    Single Station Microtremor method, which is widely used nowadays, is an effective and easy applicable method. In this study, dynamic amplification factor distributions of the study area were obtained using scenario earthquake parameters with single station microtremor data gathered at 112 points. In addition, a surface wave active method, which is known as MASW (Multichannel Analysis of Surface Waves), was applied at 43 profiles to calculate the soil amplification values. Dynamic amplification factor (DAF), soil amplification, the predominant soil period (PSP), geology and topography data of the study area were analysed together. Dynamic amplification factor and soil amplification values were obtained 2 or higher at about sea level parts of the study area which are generally composed of alluvial units. Additionally, in high altitude regions that are composed of volcanic rocks, relatively lower dynamic amplification factor and soil amplification values were obtained. The minimum amplification value in the study area was 1.15, while the maximum amplification value was 3.05 according to the dynamic amplification results and the soil amplification values were between 1.16 and 3.85 in harmony. It is seen that the obtained DAF values and the soil amplification values calculated from the seismic velocities are very similar to each other numerically and regionally. Because of this, it is concluded that the values of the soil amplification obtained by the MASW method and the calculated DAF values in this study are in harmony with each other. Although the depths of research in these two calculation methods are different from each other, the similarity of the results allows us to arrive at the result of how effective the ground layer is on the amplification. It has a great importance to calculate the amplification values and other dynamic parameters by in situ measurements for a planned plot because geological units can vary even at very short distances in heterogeneously

  11. RNA amplification for successful gene profiling analysis

    Directory of Open Access Journals (Sweden)

    Wang Ena

    2005-07-01

    Full Text Available Abstract The study of clinical samples is often limited by the amount of material available to study. While proteins cannot be multiplied in their natural form, DNA and RNA can be amplified from small specimens and used for high-throughput analyses. Therefore, genetic studies offer the best opportunity to screen for novel insights of human pathology when little material is available. Precise estimates of DNA copy numbers in a given specimen are necessary. However, most studies investigate static variables such as the genetic background of patients or mutations within pathological specimens without a need to assess proportionality of expression among different genes throughout the genome. Comparative genomic hybridization of DNA samples represents a crude exception to this rule since genomic amplification or deletion is compared among different specimens directly. For gene expression analysis, however, it is critical to accurately estimate the proportional expression of distinct RNA transcripts since such proportions directly govern cell function by modulating protein expression. Furthermore, comparative estimates of relative RNA expression at different time points portray the response of cells to environmental stimuli, indirectly informing about broader biological events affecting a particular tissue in physiological or pathological conditions. This cognitive reaction of cells is similar to the detection of electroencephalographic patterns which inform about the status of the brain in response to external stimuli. As our need to understand human pathophysiology at the global level increases, the development and refinement of technologies for high fidelity messenger RNA amplification have become the focus of increasing interest during the past decade. The need to increase the abundance of RNA has been met not only for gene specific amplification, but, most importantly for global transcriptome wide, unbiased amplification. Now gene

  12. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  13. Issues concerning outer space investments in international law ...

    African Journals Online (AJOL)

    Issues concerning outer space investments in international law. ... Recent improvements in technology have in essence increased the viability of outer space as the next frontier for international investment and development. In addition to ... Key words: Outer Space, Investments, International Law, International Space Station ...

  14. Digital Microfluidics for Nucleic Acid Amplification

    Directory of Open Access Journals (Sweden)

    Beatriz Coelho

    2017-06-01

    Full Text Available Digital Microfluidics (DMF has emerged as a disruptive methodology for the control and manipulation of low volume droplets. In DMF, each droplet acts as a single reactor, which allows for extensive multiparallelization of biological and chemical reactions at a much smaller scale. DMF devices open entirely new and promising pathways for multiplex analysis and reaction occurring in a miniaturized format, thus allowing for healthcare decentralization from major laboratories to point-of-care with accurate, robust and inexpensive molecular diagnostics. Here, we shall focus on DMF platforms specifically designed for nucleic acid amplification, which is key for molecular diagnostics of several diseases and conditions, from pathogen identification to cancer mutations detection. Particular attention will be given to the device architecture, materials and nucleic acid amplification applications in validated settings.

  15. Light amplification by seeded Kerr instability

    Science.gov (United States)

    Vampa, G.; Hammond, T. J.; Nesrallah, M.; Naumov, A. Yu.; Corkum, P. B.; Brabec, T.

    2018-02-01

    Amplification of femtosecond laser pulses typically requires a lasing medium or a nonlinear crystal. In either case, the chemical properties of the lasing medium or the momentum conservation in the nonlinear crystal constrain the frequency and the bandwidth of the amplified pulses. We demonstrate high gain amplification (greater than 1000) of widely tunable (0.5 to 2.2 micrometers) and short (less than 60 femtosecond) laser pulses, up to intensities of 1 terawatt per square centimeter, by seeding the modulation instability in an Y3Al5O12 crystal pumped by femtosecond near-infrared pulses. Our method avoids constraints related to doping and phase matching and therefore can occur in a wider pool of glasses and crystals even at far-infrared frequencies and for single-cycle pulses. Such amplified pulses are ideal to study strong-field processes in solids and highly excited states in gases.

  16. Parametric nanomechanical amplification at very high frequency.

    Science.gov (United States)

    Karabalin, R B; Feng, X L; Roukes, M L

    2009-09-01

    Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS). Compound mechanical nanostructures patterned by multilayer, top-down nanofabrication are read out by a novel scheme that parametrically modulates longitudinal stress in doubly clamped beam NEMS resonators. Parametric pumping and signal amplification are demonstrated for VHF resonators up to approximately 130 MHz and provide useful enhancement of both resonance signal amplitude and quality factor. We find that Joule heating and reduced thermal conductance in these nanostructures ultimately impose an upper limit to device performance. We develop a theoretical model to account for both the parametric response and nonequilibrium thermal transport in these composite nanostructures. The results closely conform to our experimental observations, elucidate the frequency and threshold-voltage scaling in parametric VHF NEMS resonators and sensors, and establish the ultimate sensitivity limits of this approach.

  17. Dark matter in the outer solar system

    Science.gov (United States)

    Owen, T.; Cruikshank, D.; De Bergh, C.; Geballe, T.

    1994-01-01

    There are now a large number of small bodies in the outer solar system that are known to be covered with dark material. Attempts to identify that material have been thwarted by the absence of discrete absorption features in the reflection spectra of these planetesimals. An absorption at 2.2 micrometers that appeared to be present in several objects has not been confirmed by new observations. Three absorptions in the spectrum of the unusually red planetesimal 5145 Pholus are well-established, but their identity remains a mystery.

  18. Inner and Outer Life at Work

    DEFF Research Database (Denmark)

    Lundgaard Andersen, Linda

    2012-01-01

    involving people to people interactions offered by psychodynamic theories and methods take up a pivotal position. Psychoanalytic organisational and work life research explores how work, organisations and individuals are affected by psychic dynamics, the influence of the unconscious in the forms of human...... development and interaction situated in a societal context. Based on this substantial work I draw upon two influential psychoanalytical positions—the British Tavistock position and German psychoanalytic social psychology in order to situate and identify how to understand the inner and outer life at work...

  19. The urgency of outer territories anthropology

    Directory of Open Access Journals (Sweden)

    Miloš Milenković

    2016-02-01

    Full Text Available In the context of transforming a part of Serbian anthropology into social theoretic management of identity, I suggest both comparative historiographic and ethnographic learning from societies with similar post-colonial experience, with the aim to include the discipline into an urgent defense of Serbia and Belgrade from further ethno-profiteering interests of elites in/from outer territories, left over on the ruins of our ill judged, resource incompatible, exaggerated or immoral twentieth century adventures. Serbian anthropology, written by anthropologists to whom Serbia and Belgrade are "homeland" by origin or civilized choice, should play the key role in the defense of Serbian citizens from the interest of elites in/from the outer "homelands", particularly by revealing the processes for which it is, as a discipline, most expert at – the professionalization of ethnicity, interactive and hybrid nature of identity, instrumental nature of tradition and the identity politics in general. Having in mind the latest attempt, a particularly successful one, conducted by the end of the 20th and the beginning of the 21st century that the lives, health, well-being, dignity and future of persons born in and loyal to the interest of Serbia and Belgrade, in large scale, thoroughly and long term be sacrificed and dedicated to the interests of ethno-profiteering elites in/from outer territories, in this article I point to the possibility to, along with the comparative learning from the above mentioned post-colonial experiences, delicate experiences of urgent anthropology be applied as well as the rich tradition of collective research. This text analyzes the results of first such research, that represenst the initial, praiseworthy and a brave step in the wise striving to engage social sciences and humanities in a search of expert and not mythical/daily-political solutions of the key problem of the Serbian nation – that of how to settle the interests of the

  20. Hormonal Involvement in Breast Cancer Gene Amplification

    Science.gov (United States)

    2010-10-01

    been shown to induce DN A amplification in yeast (Gopalakrishnan et al., 2001; Nguy en et al., 2001; Green et al., 2006) an d increased Cdt1 results in...re-replication in human cells (Dorn et al., 2008). The N- terminus of Cdt1 is important for re-replication, perhaps through interactions with PCNA...evolution of a cancer genome. Genome Res. (Epub. Dec. 3, 2008). Harris TD, Buzby PR, Babcock H, Beer E, Bowers J, Bras lavsky I, Causey M

  1. Fast amplification system for gamma spectroscopy

    International Nuclear Information System (INIS)

    Jesus, E.F.O.; Lopes, R.T.

    1992-01-01

    An amplification system for gamma spectroscopy with high counting rates was developed. The system was constructed with operational amplifiers, and tested and compared with ORTEC conventional system, using Iridium-192 as source of 9,25 x 10 1 0 Bq of activity and NaI (Tl) detector. The constructed system showed a better performance in relation to efficiency and resolution parameters, tested before. (C.G.C.)

  2. Optimized thermal amplification in a radiative transistor

    Energy Technology Data Exchange (ETDEWEB)

    Prod' homme, Hugo; Ordonez-Miranda, Jose; Ezzahri, Younes, E-mail: younes.ezzahri@univ-poitiers.fr; Drevillon, Jeremie; Joulain, Karl [Institut Pprime, CNRS, Université de Poitiers, ISAE-ENSMA, F-86962 Futuroscope Chasseneuil (France)

    2016-05-21

    The thermal performance of a far-field radiative transistor made up of a VO{sub 2} base in between a blackbody collector and a blackbody emitter is theoretically studied and optimized. This is done by using the grey approximation on the emissivity of VO{sub 2} and deriving analytical expressions for the involved heat fluxes and transistor amplification factor. It is shown that this amplification factor can be maximized by tuning the base temperature close to its critical one, which is determined by the temperature derivative of the VO{sub 2} emissivity and the equilibrium temperatures of the collector and emitter. This maximization is the result of the presence of two bi-stable temperatures appearing during the heating and cooling processes of the VO{sub 2} base and enables a thermal switching (temperature jump) characterized by a sizeable variation of the collector-to-base and base-to-emitter heat fluxes associated with a slight change of the applied power to the base. This switching effect leads to the optimization of the amplification factor and therefore it could be used for thermal modulation purposes.

  3. HER-2 amplification in tubular carcinoma of the breast.

    Science.gov (United States)

    Oakley, Gerard J; Tubbs, Raymond R; Crowe, Joseph; Sebek, Bruce; Budd, G Thomas; Patrick, Rebecca J; Procop, Gary W

    2006-07-01

    The prognostic and therapeutic implications of HER-2 gene amplification and estrogen and progesterone receptor status in breast cancer are well described. To address the relative paucity of information concerning HER-2 amplification for tubular carcinomas, we assessed the frequency of gene amplification in 55 tubular carcinomas of the breast from 54 patients, 5 of which had axillary node metastases. The HER-2 gene copy number was assessed by fluorescence in situ hybridization for the majority of tumors analyzed, whereas estrogen and progesterone receptor status was achieved by immunohistochemical analysis. HER-2 gene amplification was not observed in any of the tumors examined, and most were estrogen receptor-positive. This HER-2 gene amplification frequency was significantly lower than the frequency of gene amplification previously reported for all invasive ductal carcinoma of no special type (P < .01). HER-2 gene amplification likely occurs infrequently, or not at all, in tubular carcinomas of the breast, whereas most express estrogen receptors.

  4. Noise alters guinea pig's blood-labyrinth barrier ultrastructure and permeability along with a decrease of cochlear Claudin-5 and Occludin.

    Science.gov (United States)

    Wu, Yong-Xiang; Zhu, Guo-Xia; Liu, Xin-Qin; Sun, Fei; Zhou, Ke; Wang, Shuang; Wang, Chun-Mei; Jia, Jin-Wen; Song, Jian-Tao; Lu, Lian-Jun

    2014-12-24

    Noise exposure (NE) is a severe modern health hazard that induces hearing impairment. However, the noise-induced ultrastructural changes of blood-labyrinth barrier (BLB) and the potential involvements of tight junction proteins (TJP) remain inconclusive. We investigated the effects of NE on not only the ultrastructure of cochlea and permeability of BLB but also the expression of TJP within the guinea pig cochlea. Male albino guinea pigs were exposed to white noise for 4 h or 2 consecutive days (115 dB sound pressure level, 6 hours per day) and the hearing impairments and light microscopic change of BLB were evaluated with auditory brainstem responses (ABR) and the cochlear sensory epithelia surface preparation, respectively. The cochlear ultrastructure and BLB permeability after NE 2d were revealed with transmission electron microscope (TEM) and lanthanum nitrate-tracing techniques, respectively. The potential alterations of TJPs Claudin-5 and Occludin were quantified with immunohistochemistry and western blot. NE induced significant hearing impairment and NE 2d contributed to significant outer hair cell (OHC) loss that is most severe in the first row of outer hair cells. Furthermore, the loosen TJ and an obvious leakage of lanthanum nitrate particles beneath the basal lamina were revealed with TEM. Moreover, a dose-dependent decrease of Claudin-5 and Occludin was observed in the cochlea after NE. All these findings suggest that both decrease of Claudin-5 and Occludin and increased BLB permeability are involved in the pathologic process of noise-induced hearing impairment; however, the causal relationship and underlying mechanisms should be further investigated.

  5. The goya mouse mutant reveals distinct newly identified roles for MAP3K1 in the development and survival of cochlear sensory hair cells

    Directory of Open Access Journals (Sweden)

    Andrew Parker

    2015-12-01

    Full Text Available Mitogen-activated protein kinase, MAP3K1, plays an important role in a number of cellular processes, including epithelial migration during eye organogenesis. In addition, studies in keratinocytes indicate that MAP3K1 signalling through JNK is important for actin stress fibre formation and cell migration. However, MAP3K1 can also act independently of JNK in the regulation of cell proliferation and apoptosis. We have identified a mouse mutant, goya, which exhibits the eyes-open-at-birth and microphthalmia phenotypes. In addition, these mice also have hearing loss. The goya mice carry a splice site mutation in the Map3k1 gene. We show that goya and kinase-deficient Map3k1 homozygotes initially develop supernumerary cochlear outer hair cells (OHCs that subsequently degenerate, and a progressive profound hearing loss is observed by 9 weeks of age. Heterozygote mice also develop supernumerary OHCs, but no cellular degeneration or hearing loss is observed. MAP3K1 is expressed in a number of inner-ear cell types, including outer and inner hair cells, stria vascularis and spiral ganglion. Investigation of targets downstream of MAP3K1 identified an increase in p38 phosphorylation (Thr180/Tyr182 in multiple cochlear tissues. We also show that the extra OHCs do not arise from aberrant control of proliferation via p27KIP1. The identification of the goya mutant reveals a signalling molecule involved with hair-cell development and survival. Mammalian hair cells do not have the ability to regenerate after damage, which can lead to irreversible sensorineural hearing loss. Given the observed goya phenotype, and the many diverse cellular processes that MAP3K1 is known to act upon, further investigation of this model might help to elaborate upon the mechanisms underlying sensory hair cell specification, and pathways important for their survival. In addition, MAP3K1 is revealed as a new candidate gene for human sensorineural hearing loss.

  6. Heating of the outer solar atmosphere

    International Nuclear Information System (INIS)

    Parker, E.N.

    1983-01-01

    The author discusses the idea that there must be a source of magnetic fields somewhere below the solar surface. He starts by considering present day ideas about the sun's internal structure. The sun has a radius of approximately 700,000 km, of which the outer 100,000 km or so is the convective zone, according to mixing-length models. The dynamo is believed to operate in the convective zone, across which there may be a 5-10% variation in the angular velocity. There are the stretched east-west fields similar to the ones in the earth's core. Associated with these are poloidal fields which contribute to a net dipole moment of the sun and are generated by a dynamo. The author shows that essentially no magnetic field configuration has an equilibrium; they dissipate quickly in spite of the high conductivity in fluid motions and heating. This is probably the major part of the heating of the sun's outer atmosphere. (Auth.)

  7. Cosmics in the LHCb Outer Tracker

    CERN Document Server

    Aaij, Roel

    2010-01-01

    The LHCb experiment at the Large Hadron Collider studies the decay of B mesons to test the description of CP violation in the Standard Model and to search for new physics. The decay $B_s \\to \\mu^+ \\mu^-$ has been identified as very promising in the search for new physics. An excellent invariant mass resolution is required to suppress backgrounds to this decay. This in turn requires a momentum resolution of dp/p = 0.4%. The Outer Tracker is part of the LHCb tracking system and has been commissioned with cosmic muons. The noise in the Outer Tracker is shown to be less than 0.05%. To use drift time information in the reconstruction of cosmic tracks, the event time must be known. Four methods to obtain the event time are studied and compared. It is shown that the event time can be obtained with a resolution better than 2.6 ns. Using drift time information, tracks are reconstructed with a resolution of 344 $\\mu$m. Knowledge of the event time enables the calibration of electronic time offsets and the r(t)– relati...

  8. Gamma rays from pulsar outer gaps

    International Nuclear Information System (INIS)

    Chiang, J.; Romani, R.W.; Cheng Ho

    1993-01-01

    We describe a gamma ray pulsar code which computes the high energy photon emissivities from vacuum gaps in the outer magnetosphere, after the model outlined by Cheng, Ho and Ruderman (1986) and Ho (1989). Pair-production due to photon-photon interactions and radiation processes including curvature, synchrotron and inverse Compton processes are computed with an iterative scheme which converges to self-consistent photon and particle distributions for a sampling of locations in the outer magnetosphere. We follow the photons from these distributions as they propagate through the pulsar magnetosphere toward a distant observer. We include the effects of relativistic aberration, time-of-flight delays and reabsorption by photon-photon pair-production to determine an intensity map of the high energy pulsar emission on the sky. Using data from radio and optical observations to constrain the geometry of the magnetosphere as well as the possible observer viewing angles, we derive light curves and phase dependent spectra which can be directly compared to data from the Compton Observatory. Observations for Crab, Vela and the recently identified gamma ray pulsars Geminga, PSR1706-44 aNd PSR 1509-58 will provide important tests of our model calculations, help us to improve our picture of the relevant physics at work in pulsar magnetospheres and allow us to comment on the implications for future pulsar discoveries

  9. Residual Stress Testing of Outer 3013 Containers

    International Nuclear Information System (INIS)

    Dunn, K.

    2004-01-01

    A Gas Tungsten Arc Welded (GTAW) outer 3013 container and a laser welded outer 3013 container have been tested for residual stresses according to the American Society for Testing Materials (ASTM) Standard G-36-94 [1]. This ASTM standard describes a procedure for conducting stress-corrosion cracking tests in boiling magnesium chloride (MgCl2) solution. Container sections in both the as-fabricated condition as well as the closure welded condition were evaluated. Significantly large residual stresses were observed in the bottom half of the as-fabricated container, a result of the base to can fabrication weld because through wall cracks were observed perpendicular to the weld. This observation indicates that regardless of the closure weld technique, sufficient residual stresses exist in the as-fabricated container to provide the stress necessary for stress corrosion cracking of the container, at the base fabrication weld. Additionally, sufficiently high residual stresses were observed in both the lid and the body of the GTAW as well as the laser closure welded containers. The stresses are oriented perpendicular to the closure weld in both the container lid and the container body. Although the boiling MgCl2 test is not a quantitative test, a comparison of the test results from the closure welds shows that there are noticeably more through wall cracks in the laser closure welded container than in the GTAW closure welded container

  10. Radioiodination of an outer membrane protein in intact Rickettsia prowazekii

    International Nuclear Information System (INIS)

    Smith, D.K.; Winkler, H.H.

    1980-01-01

    Intact Rickettsia prowazekii was radiolabeled with the glucose oxidase-lactoperoxidase method of iodination. Separation of the rickettsial extract into cytoplasmic, outer and inner membrane fractions demonstrated that the outer membrane was preferentially labeled. Analysis of the polypeptides of these fractions on high-resolution slab polyacrylamide gels showed that most of the 125 I was in polypeptide T49, an outer membrane constituent. Additional outer membrane polypeptides were iodinated in broken envelope preparations, demonstrating that T49 is uniquely accessible to the external environment and the asymmetric polypeptide organization of the outer membrane

  11. A large ungated TPC with GEM amplification

    Science.gov (United States)

    Berger, M.; Ball, M.; Fabbietti, L.; Ketzer, B.; Arora, R.; Beck, R.; Böhmer, F. V.; Chen, J.-C.; Cusanno, F.; Dørheim, S.; García, F.; Hehner, J.; Herrmann, N.; Höppner, C.; Kaiser, D.; Kis̆, M.; Kleipa, V.; Konorov, I.; Kunkel, J.; Kurz, N.; Leifels, Y.; Müllner, P.; Münzer, R.; Neubert, S.; Rauch, J.; Schmidt, C. J.; Schmitz, R.; Soyk, D.; Vandenbroucke, M.; Voss, B.; Walther, D.; Zmeskal, J.

    2017-10-01

    A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost 4 π. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC). The design requirements have driven innovations in the construction of a light-weight field-cage, a supporting media flange, the GEM amplification and the readout system, which are

  12. Ototoxicity of paclitaxel in rat cochlear organotypic cultures

    International Nuclear Information System (INIS)

    Dong, Yang; Ding, Dalian; Jiang, Haiyan; Shi, Jian-rong; Salvi, Richard; Roth, Jerome A.

    2014-01-01

    Paclitaxel (taxol) is a widely used antineoplastic drug employed alone or in combination to treat many forms of cancer. Paclitaxel blocks microtubule depolymerization thereby stabilizing microtubules and suppressing cell proliferation and other cellular processes. Previous reports indicate that paclitaxel can cause mild to moderate sensorineural hearing loss and some histopathologic changes in the mouse cochlea; however, damage to the neurons and the underlying cell death mechanisms are poorly understood. To evaluate the ototoxicity of paclitaxel in more detail, cochlear organotypic cultures from postnatal day 3 rats were treated with paclitaxel for 24 or 48 h with doses ranging from 1 to 30 μM. No obvious histopathologies were observed after 24 h treatment with any of the paclitaxel doses employed, but with 48 h treatment, paclitaxel damaged cochlear hair cells in a dose-dependent manner and also damaged auditory nerve fibers and spiral ganglion neurons (SGN) near the base of the cochlea. TUNEL labeling was negative in the organ of Corti, but positive in SGN with karyorrhexis 48 h after 30 μM paclitaxel treatment. In addition, caspase-6, caspase-8 and caspase-9 labeling was present in SGN treated with 30 μM paclitaxel for 48 h. These results suggest that caspase-dependent apoptotic pathways are involved in paclitaxel-induced damage of SGN, but not hair cells in cochlea. - Highlights: • Paclitaxel was toxic to cochlear hair cells and spiral ganglion neurons. • Paclitaxel-induced spiral ganglion degeneration was apoptotic. • Paclitaxel activated caspase-6, -8 and -8 in spiral ganglion neurons

  13. Cochlear implant rehabilitation outcomes in Waardenburg syndrome children.

    Science.gov (United States)

    de Sousa Andrade, Susana Margarida; Monteiro, Ana Rita Tomé; Martins, Jorge Humberto Ferreira; Alves, Marisa Costa; Santos Silva, Luis Filipe; Quadros, Jorge Manuel Cardoso; Ribeiro, Carlos Alberto Reis

    2012-09-01

    The purpose of this study was to review the outcomes of children with documented Waardenburg syndrome implanted in the ENT Department of Centro Hospitalar de Coimbra, concerning postoperative speech perception and production, in comparison to the rest of non-syndromic implanted children. A retrospective chart review was performed for children congenitally deaf who had undergone cochlear implantation with multichannel implants, diagnosed as having Waardenburg syndrome, between 1992 and 2011. Postoperative performance outcomes were assessed and confronted with results obtained by children with non-syndromic congenital deafness also implanted in our department. Open-set auditory perception skills were evaluated by using European Portuguese speech discrimination tests (vowels test, monosyllabic word test, number word test and words in sentence test). Meaningful auditory integration scales (MAIS) and categories of auditory performance (CAP) were also measured. Speech production was further assessed and included results on meaningful use of speech Scale (MUSS) and speech intelligibility rating (SIR). To date, 6 implanted children were clinically identified as having WS type I, and one met the diagnosis of type II. All WS children received multichannel cochlear implants, with a mean age at implantation of 30.6±9.7months (ranging from 19 to 42months). Postoperative outcomes in WS children were similar to other nonsyndromic children. In addition, in number word and vowels discrimination test WS group showed slightly better performances, as well as in MUSS and MAIS assessment. Our study has shown that cochlear implantation should be considered a rehabilitative option for Waardenburg syndrome children with profound deafness, enabling the development and improvement of speech perception and production abilities in this group of patients, reinforcing their candidacy for this audio-oral rehabilitation method. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Cochlear Implant Spatial Selectivity with Monopolar, Bipolar and Tripolar Stimulation

    Science.gov (United States)

    Zhu, Ziyan; Tang, Qing; Zeng, Fan-Gang; Guan, Tian; Ye, Datian

    2011-01-01

    Sharp spatial selectivity is critical to auditory performance, particularly in pitch related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear implant performance. PMID:22138630

  15. Short-term risk of falling after cochlear implantation.

    Science.gov (United States)

    Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E

    2014-01-01

    Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.

  16. Ototoxicity of paclitaxel in rat cochlear organotypic cultures

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yang [Shanghai University of Traditional Chinese Medicine, Shanghai 201203 (China); Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Ding, Dalian; Jiang, Haiyan [Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Shi, Jian-rong [Shanghai University of Traditional Chinese Medicine, Shanghai 201203 (China); Salvi, Richard [Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Roth, Jerome A., E-mail: jaroth@buffalo.edu [Department of Pharmacology and Toxicology, University at Buffalo, NY 14214 (United States)

    2014-11-01

    Paclitaxel (taxol) is a widely used antineoplastic drug employed alone or in combination to treat many forms of cancer. Paclitaxel blocks microtubule depolymerization thereby stabilizing microtubules and suppressing cell proliferation and other cellular processes. Previous reports indicate that paclitaxel can cause mild to moderate sensorineural hearing loss and some histopathologic changes in the mouse cochlea; however, damage to the neurons and the underlying cell death mechanisms are poorly understood. To evaluate the ototoxicity of paclitaxel in more detail, cochlear organotypic cultures from postnatal day 3 rats were treated with paclitaxel for 24 or 48 h with doses ranging from 1 to 30 μM. No obvious histopathologies were observed after 24 h treatment with any of the paclitaxel doses employed, but with 48 h treatment, paclitaxel damaged cochlear hair cells in a dose-dependent manner and also damaged auditory nerve fibers and spiral ganglion neurons (SGN) near the base of the cochlea. TUNEL labeling was negative in the organ of Corti, but positive in SGN with karyorrhexis 48 h after 30 μM paclitaxel treatment. In addition, caspase-6, caspase-8 and caspase-9 labeling was present in SGN treated with 30 μM paclitaxel for 48 h. These results suggest that caspase-dependent apoptotic pathways are involved in paclitaxel-induced damage of SGN, but not hair cells in cochlea. - Highlights: • Paclitaxel was toxic to cochlear hair cells and spiral ganglion neurons. • Paclitaxel-induced spiral ganglion degeneration was apoptotic. • Paclitaxel activated caspase-6, -8 and -8 in spiral ganglion neurons.

  17. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  18. Safety of Monopolar Electrocautery in Patients With Cochlear Implants.

    Science.gov (United States)

    Tien, Duc A; Woodson, Erika A; Anne, Samantha

    2016-09-01

    The outcomes of 2 patients with cochlear implants (CIs) who underwent adenotonsillectomy (AT) with inadvertent use of monopolar cautery are presented. The safety data regarding monopolar cautery use in CI recipients is also reviewed. This is a retrospective case series of 2 CI recipients that underwent AT with monopolar cautery and literature review of electrocautery safety in the setting of CI. Two patients with CIs underwent AT with use of monopolar cautery inadvertently by surgeons that do not routinely perform cochlear implants as part of his or her clinical practice. Patient 1 was a 9-year-old female who had AT for obstructive sleep apnea (OSA) after undergoing unilateral CI for profound congenital sensorineural hearing loss (SNHL) 8 years ago. Patient 2 was a 7-year-old female who underwent AT for OSA 4 months after undergoing unilateral CI for congenital SNHL. Both patients had no immediate signs of complications with their CI use postoperatively. Both patients demonstrated unchanged postoperative neural response telemetry and behavioral audiometric testing. Patient 1 continues to have no CI-related complications 3.5 years after the procedure. Patient 2 has been followed for at least 3 months by audiometric testing and 10 months by otolaryngologist with no CI-related complications. Although animal and cadaveric studies suggest that monopolar cautery may be safely used in patients with cochlear implants, there have been no in vivo human studies that have evaluated the risk to the patient or implant. This is a report of a small, unintended experience with 2 patients, both of whom exhibit no complications or changes to CI function thus far. © The Author(s) 2016.

  19. [Responses of bat cochlear nucleus neurons to ultrasonic stimuli].

    Science.gov (United States)

    Vasil'ev, A G; Grigor'eva, T I

    1977-01-01

    The responses of cochlear nuclei single units in Vespertilionidae and Rhinolophidae were studied by means of ultrasound stimuli of different frequencies. Most neurons were found to have one or two complementary response areas with best frequencies equal to 1/2 and 1/3 of the highest one (which we regard as the basic best frequency). In Vespertilionidae which emit frequency-modulated signals some neurons have complementary areas with upper thresholds. The latency of responses do not correlate with the stimulus frequency. This suggests that there is no correlative reception of echosignals at this level of auditory system in bats.

  20. Perceptual Interactions Between Electrodes Using Focused and Monopolar Cochlear Stimulation

    DEFF Research Database (Denmark)

    Marozeau, Jeremy; McDermott, Hugh J.; Swanson, Brett A.

    2015-01-01

    -matched sequential and simultaneous stimuli composed of 2 spatially separated pulse trains was measured as function of the electrode separation. Results indicated a strong current-summation interaction for simultaneous stimuli in the MP mode for separations up to at least 4.8 mm. No significant interaction was found......In today’s cochlear implant (CI) systems, the monopolar (MP) electrode configuration is the most commonly used stimulation mode, requiring only a single current source. However, with an implant that will allow simultaneous activation of multiple independent current sources, it is possible...

  1. Cochlear implantation for severe sensorineural hearing loss caused by lightning.

    Science.gov (United States)

    Myung, Nam-Suk; Lee, Il-Woo; Goh, Eui-Kyung; Kong, Soo-Keun

    2012-01-01

    Lightning strike can produce an array of clinical symptoms and injuries. It may damage multiple organs and cause auditory injuries ranging from transient hearing loss and vertigo to complete disruption of the auditory system. Tympanic-membrane rupture is relatively common in patients with lightning injury. The exact pathogenetic mechanisms of auditory lesions in lightning survivors have not been fully elucidated. We report the case of a 45-year-old woman with bilateral profound sensorineural hearing loss caused by a lightning strike, who was successfully rehabilitated after a cochlear implantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Development of Mandarin spoken language after pediatric cochlear implantation.

    Science.gov (United States)

    Li, Bei; Soli, Sigfrid D; Zheng, Yun; Li, Gang; Meng, Zhaoli

    2014-07-01

    The purpose of this study was to evaluate early spoken language development in young Mandarin-speaking children during the first 24 months after cochlear implantation, as measured by receptive and expressive vocabulary growth rates. Growth rates were compared with those of normally hearing children and with growth rates for English-speaking children with cochlear implants. Receptive and expressive vocabularies were measured with the simplified short form (SSF) version of the Mandarin Communicative Development Inventory (MCDI) in a sample of 112 pediatric implant recipients at baseline, 3, 6, 12, and 24 months after implantation. Implant ages ranged from 1 to 5 years. Scores were expressed in terms of normal equivalent ages, allowing normalized vocabulary growth rates to be determined. Scores for English-speaking children were re-expressed in these terms, allowing direct comparisons of Mandarin and English early spoken language development. Vocabulary growth rates during the first 12 months after implantation were similar to those for normally hearing children less than 16 months of age. Comparisons with growth rates for normally hearing children 16-30 months of age showed that the youngest implant age group (1-2 years) had an average growth rate of 0.68 that of normally hearing children; while the middle implant age group (2-3 years) had an average growth rate of 0.65; and the oldest implant age group (>3 years) had an average growth rate of 0.56, significantly less than the other two rates. Growth rates for English-speaking children with cochlear implants were 0.68 in the youngest group, 0.54 in the middle group, and 0.57 in the oldest group. Growth rates in the middle implant age groups for the two languages differed significantly. The SSF version of the MCDI is suitable for assessment of Mandarin language development during the first 24 months after cochlear implantation. Effects of implant age and duration of implantation can be compared directly across

  3. Dual Coding of Frequency Modulation in the Ventral Cochlear Nucleus.

    Science.gov (United States)

    Paraouty, Nihaad; Stasiak, Arkadiusz; Lorenzi, Christian; Varnet, Léo; Winter, Ian M

    2018-04-25

    Frequency modulation (FM) is a common acoustic feature of natural sounds and is known to play a role in robust sound source recognition. Auditory neurons show precise stimulus-synchronized discharge patterns that may be used for the representation of low-rate FM. However, it remains unclear whether this representation is based on synchronization to slow temporal envelope (ENV) cues resulting from cochlear filtering or phase locking to faster temporal fine structure (TFS) cues. To investigate the plausibility of those encoding schemes, single units of the ventral cochlear nucleus of guinea pigs of either sex were recorded in response to sine FM tones centered at the unit's best frequency (BF). The results show that, in contrast to high-BF units, for modulation depths within the receptive field, low-BF units (modulation depths extending beyond the receptive field, the discharge patterns follow the ENV and fluctuate at the modulation rate. The receptive field proved to be a good predictor of the ENV responses for most primary-like and chopper units. The current in vivo data also reveal a high level of diversity in responses across unit types. TFS cues are mainly conveyed by low-frequency and primary-like units and ENV cues by chopper and onset units. The diversity of responses exhibited by cochlear nucleus neurons provides a neural basis for a dual-coding scheme of FM in the brainstem based on both ENV and TFS cues. SIGNIFICANCE STATEMENT Natural sounds, including speech, convey informative temporal modulations in frequency. Understanding how the auditory system represents those frequency modulations (FM) has important implications as robust sound source recognition depends crucially on the reception of low-rate FM cues. Here, we recorded 115 single-unit responses from the ventral cochlear nucleus in response to FM and provide the first physiological evidence of a dual-coding mechanism of FM via synchronization to temporal envelope cues and phase locking to temporal

  4. Use of CT in the evaluation of cochlear otosclerosis

    International Nuclear Information System (INIS)

    Mafee, M.F.; Valvassori, G.E.; Deitch, R.L.; Norouzi, P.; Henrikson, G.C.; Capek, V.; Applebaum, E.L.

    1985-01-01

    Otosclerosis (otospongiosis) occurs when the hard endochondral bone of the otic capsule is replaced by spongy vascular foci of haversian bone. Using computed tomography (CT), the authors studied the ears of 32 selected patients with mixed or sensorineural hearing loss; 24 were suspected of having otosclerosis. CT proved valuable in detecting cochlear otosclerosis, foci of demineralization, and changes in bony texture and enables the easy recognition of subtle radiographic findings. This paper also reports the CT findings of temporal bones in osteogenesis imperfecta and Paget disease

  5. [Strategy for minimally invasive cochlear implantation and residual hearing preservation].

    Science.gov (United States)

    Huang, Y Y; Chen, J Y; Shen, M; Yang, J

    2018-01-07

    In the past few decades, considerable development was achieved in the cochlear implantation following the emergence of innovative electrode array and advances in minimally invasive surgery. Minimally invasive technique led to a better preservation of residual low-frequency hearing. The loss of residual hearing was caused by complicated factors. According to previous studies, a slower and stable speed of electrode insertion and the use of perioperative steroids were demonstrated to have a positive impact on hearing preservation. The selection of electrode array or its insertion approaches didn't show any distinctive benefits in hearing preservation.

  6. Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2007-04-01

    The study goals were to examine whether cochlear implantation increases the risk of meningitis in the absence of other risk factors and to understand the pathogenesis of pneumococcal meningitis post cochlear implantation. Four weeks following surgery, 54 rats (18 of which received a cochleostomy alone, 18 of which received a cochleostomy and acute cochlear implantation using standard surgical techniques, and 18 of which received a cochlear implant) were infected with Streptococcus pneumoniae via three different routes of bacterial inoculation (middle ear, inner ear, and intraperitoneal) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges. The presence of a cochlear implant reduced the threshold of bacteria required to cause pneumococcal meningitis from all routes of infection in healthy animals. The presence of a cochlear implant increases the risk of pneumococcal meningitis regardless of the route of bacterial infection. Early detection and treatment of pneumococcal infection such as otitis media may be required, as cochlear implantation may lead to a reduction of infectious threshold for meningitis.

  7. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  8. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    Science.gov (United States)

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  9. Loop mediated isothermal amplification: An innovative gene amplification technique for animal diseases

    Directory of Open Access Journals (Sweden)

    Pravas Ranjan Sahoo

    2016-05-01

    Full Text Available India being a developing country mainly depends on livestock sector for its economy. However, nowadays, there is emergence and reemergence of more transboundary animal diseases. The existing diagnostic techniques are not so quick and with less specificity. To reduce the economy loss, there should be a development of rapid, reliable, robust diagnostic technique, which can work with high degree of sensitivity and specificity. Loop mediated isothermal amplification assay is a rapid gene amplification technique that amplifies nucleic acid under an isothermal condition with a set of designed primers spanning eight distinct sequences of the target. This assay can be used as an emerging powerful, innovative gene amplification diagnostic tool against various pathogens of livestock diseases. This review is to highlight the basic concept and methodology of this assay in livestock disease.

  10. Loop mediated isothermal amplification: An innovative gene amplification technique for animal diseases.

    Science.gov (United States)

    Sahoo, Pravas Ranjan; Sethy, Kamadev; Mohapatra, Swagat; Panda, Debasis

    2016-05-01

    India being a developing country mainly depends on livestock sector for its economy. However, nowadays, there is emergence and reemergence of more transboundary animal diseases. The existing diagnostic techniques are not so quick and with less specificity. To reduce the economy loss, there should be a development of rapid, reliable, robust diagnostic technique, which can work with high degree of sensitivity and specificity. Loop mediated isothermal amplification assay is a rapid gene amplification technique that amplifies nucleic acid under an isothermal condition with a set of designed primers spanning eight distinct sequences of the target. This assay can be used as an emerging powerful, innovative gene amplification diagnostic tool against various pathogens of livestock diseases. This review is to highlight the basic concept and methodology of this assay in livestock disease.

  11. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    Science.gov (United States)

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  12. Speech Perception Outcomes after Cochlear Implantation in Children with GJB2/DFNB1 associated Deafness

    Directory of Open Access Journals (Sweden)

    Marina Davcheva-Chakar

    2014-03-01

    Full Text Available Background: Cochlear implants (CI for the rehabilitation of patients with profound or total bilateral sensorineural hypoacusis represent the initial use of electrical fields to provide audibility in cases where the use of sound amplifiers does not provide satisfactory results. Aims: To compare speech perception performance after cochlear implantation in children with connexin 26-associated deafness with that of a control group of children with deafness of unknown etiology. Study Design: Retrospective comparative study. Methods: During the period from 2006 to , cochlear implantation was performed on 26 children. Eighteen of these children had undergone genetic tests for mutation of the Gap Junction Protein Beta 2 (GJB2 gene. Bi-allelic GJB2 mutations were confirmed in 7 out of 18 examined children. In order to confirm whether genetic factors have influence on speech perception after cochlear implantation, we compared the post-implantation speech performance of seven children with mutations of the GBJ2 (connexin 26 gene with seven other children who had the wild type version of this particular gene. The latter were carefully matched according to the age at cochlear implantation. Speech perception performance was measured before cochlear implantation, and one and two years after implantation. All the patients were arranged in line with the appropriate speech perception category (SPC. Non-parametric tests, Friedman ANOVA and Mann-Whitney’s U test were used for statistical analysis. Results: Both groups showed similar improvements in speech perception scores after cochlear implantation. Statistical analysis did not confirm significant differences between the groups 12 and 24 months after cochlear implantation. Conclusion: The results obtained in this study showed an absence of apparent distinctions in the scores of speech perception between the two examined groups and therefore might have significant implications in selecting prognostic indicators

  13. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  14. CT study of 17 cases of congenital cochlear abnormality. Embryologic and anatomo-functional relationship

    OpenAIRE

    Maurício, JC; Biscoito, L; Branco, G

    1993-01-01

    In this review of cochlear malformations, 17 cases were studied by CT scan (high resolution-target program) including 10 males and 7 females. The anomaly was bilateral in 12 cases and unilateral in 7 (the latter included 2 Mondini type aplasias and one Michel). The cochlear malformation (whose most frequent expression was the cochlear hypoplasia with 1 or 1 1/2 spires-65% of the cases) was associated to semicircular canals and/or vestibular aqueduct anomaly in 82% of the patients; it was excl...

  15. Simultaneous Bilateral Cochlear Implantation for a 6-Month Child with a History of Meningitis

    Directory of Open Access Journals (Sweden)

    Kh. M. Diab

    2015-01-01

    Full Text Available The article presents the first case of simultaneous bilateral cochlear implantation for a 6-month child with IV degree sensorineural hearing loss after meningocephalitis in Russia. Despite partial ossification of the cochlear basal turns, the early timing of implantation allowed to fully implant active electrodes to both ears. The simultaneous bilateral cochlear implantation in young children, who had meningitis, is a minimally invasive and highly efficient procedure with good long-term results of oral-aural after-care.

  16. Central transport and distribution of labelled glutamic and aspartic acids to the cochlear nucleus in cats

    International Nuclear Information System (INIS)

    Kane, E.S.

    1979-01-01

    Tritiated L-glutamic acid or L-aspartic acid was injected unilaterally into the cochleas of adult cats, and 4 h-7 days later the localization of label was studied by light-microscopic autoradiography in sections of the brain stem. Consistent differences in labelling after glutamate and after aspartate suggest differences in their uptake, metabolic conversion and/or transport to the cochlear nucleus by cochlear fibers. The morphological differences shown here agree with the distribution of those two amino acids in the cat cochlear nucleus as shown by microchemical analyses. (author)

  17. Recurrent Neural Network for Computing Outer Inverse.

    Science.gov (United States)

    Živković, Ivan S; Stanimirović, Predrag S; Wei, Yimin

    2016-05-01

    Two linear recurrent neural networks for generating outer inverses with prescribed range and null space are defined. Each of the proposed recurrent neural networks is based on the matrix-valued differential equation, a generalization of dynamic equations proposed earlier for the nonsingular matrix inversion, the Moore-Penrose inversion, as well as the Drazin inversion, under the condition of zero initial state. The application of the first approach is conditioned by the properties of the spectrum of a certain matrix; the second approach eliminates this drawback, though at the cost of increasing the number of matrix operations. The cases corresponding to the most common generalized inverses are defined. The conditions that ensure stability of the proposed neural network are presented. Illustrative examples present the results of numerical simulations.

  18. Ageing of the LHCb outer tracker

    CERN Document Server

    Blom, M R; Tuning, N

    2009-01-01

    The modules of the LHCb outer tracker have shown to suffer severe gain loss under moderate irradiation. This process is called ageing. Ageing of the modules results from contamination of the gas system by glue, araldite AY 103-1, used in their construction. In this thesis the ageing process will be shown. The schemes known to reduce, reverse, or prevent ageing have been investigated to determine their effect on the detector performance. The addition of O2 to the gas mixture lowers the detector response by an acceptable amount and does not affect the gas transport properties significantly. The ageing rate is decreased after extensive flushing and HV training could eventually repair the irradiation damage. The risks of HV training have been assessed. Furthermore, several gaseous and aquatic additions have been tested for their capability to prevent, or moderate ageing, but none showed significant improvement.

  19. The fate of the outer plasmasphere

    International Nuclear Information System (INIS)

    Elphic, R.C.; Thomsen, M.F.; Borovsky, J.E.

    1997-01-01

    Both the solar wind and the ionosphere contribute to Earth close-quote s magnetospheric plasma environment. However, it is not widely appreciated that the plasmasphere is a large reservoir of ionospheric ions that can be tapped to populate the plasma sheet. We employ empirical models of high-latitude ionospheric convection and the geomagnetic field to describe the transport of outer plasmasphere flux tubes from the dayside, over the polar cap and into the magnetotail during the early phases of a geomagnetic storm. We calculate that this process can give rise to high densities of cold plasma in the magnetotail lobes and in the near-Earth plasma sheet during times of enhanced geomagnetic activity, and especially during storms. This model can help explain both polar cap ionization patches and the presence of cold flowing ions downtail.copyright 1997 American Geophysical Union

  20. Impulsive ion acceleration in earth's outer magnetosphere

    International Nuclear Information System (INIS)

    Baker, D.N.; Belian, R.D.

    1985-01-01

    Considerable observational evidence is found that ions are accelerated to high energies in the outer magnetosphere during geomagnetic disturbances. The acceleration often appears to be quite impulsive causing temporally brief (10's of seconds), very intense bursts of ions in the distant plasma sheet as well as in the near-tail region. These ion bursts extend in energy from 10's of keV to over 1 MeV and are closely associated with substorm expansive phase onsets. Although the very energetic ions are not of dominant importance for magnetotail plasma dynamics, they serve as an important tracer population. Their absolute intensity and brief temporal appearance bespeaks a strong and rapid acceleration process in the near-tail, very probably involving large induced electric fields substantially greater than those associated with cross-tail potential drops. Subsequent to their impulsive acceleration, these ions are injected into the outer trapping regions forming ion ''drift echo'' events, as well as streaming tailward away from their acceleration site in the near-earth plasma sheet. Most auroral ion acceleration processes occur (or are greatly enhanced) during the time that these global magnetospheric events are occurring in the magnetotail. A qualitative model relating energetic ion populations to near-tail magnetic reconnection at substorm onset followed by global redistribution is quite successful in explaining the primary observational features. Recent measurements of the elemental composition and charge-states have proven valuable for showing the source (solar wind or ionosphere) of the original plasma population from which the ions were accelerated

  1. Involving young people in decision making about sequential cochlear implantation.

    Science.gov (United States)

    Ion, Rebecca; Cropper, Jenny; Walters, Hazel

    2013-11-01

    The National Institute for Health and Clinical Excellence guidelines recommended young people who currently have one cochlear implant be offered assessment for a second, sequential implant, due to the reported improvements in sound localization and speech perception in noise. The possibility and benefits of group information and counselling assessments were considered. Previous research has shown advantages of group sessions involving young people and their families and such groups which also allow young people opportunity to discuss their concerns separately to their parents/guardians are found to be 'hugely important'. Such research highlights the importance of involving children in decision-making processes. Families considering a sequential cochlear implant were invited to a group information/counselling session, which included time for parents and children to meet separately. Fourteen groups were held with approximately four to five families in each session, totalling 62 patients. The sessions were facilitated by the multi-disciplinary team, with a particular psychological focus in the young people's session. Feedback from families has demonstrated positive support for this format. Questionnaire feedback, to which nine families responded, indicated that seven preferred the group session to an individual session and all approved of separate groups for the child and parents/guardians. Overall the group format and psychological focus were well received in this typically surgical setting and emphasized the importance of involving the young person in the decision-making process. This positive feedback also opens up the opportunity to use a group format in other assessment processes.

  2. Fluid coupling in a discrete model of cochlear mechanics.

    Science.gov (United States)

    Elliott, Stephen J; Lineton, Ben; Ni, Guangjian

    2011-09-01

    A discrete model of cochlear mechanics is introduced that includes a full, three-dimensional, description of fluid coupling. This formulation allows the fluid coupling and basilar membrane dynamics to be analyzed separately and then coupled together with a simple piece of linear algebra. The fluid coupling is initially analyzed using a wavenumber formulation and is separated into one component due to one-dimensional fluid coupling and one comprising all the other contributions. Using the theory of acoustic waves in a duct, however, these two components of the pressure can also be associated with a far field, due to the plane wave, and a near field, due to the evanescent, higher order, modes. The near field components are then seen as one of a number of sources of additional longitudinal coupling in the cochlea. The effects of non-uniformity and asymmetry in the fluid chamber areas can also be taken into account, to predict both the pressure difference between the chambers and the mean pressure. This allows the calculation, for example, of the effect of a short cochlear implant on the coupled response of the cochlea. © 2011 Acoustical Society of America

  3. Cochlear implantation in children and adults in Switzerland.

    Science.gov (United States)

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H J

    2014-02-04

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

  4. Surgical treatment of vertigo in cochlear implantees by electrode resealing.

    Science.gov (United States)

    Karimi, Dania; Mittmann, Philipp; Ernst, Arneborg; Todt, Ingo

    2017-10-01

    Our present findings demonstrate that resealing to cover the electrode is an effective method to treat vertigo after CI. An insufficient cochleostomy sealing can be regarded as a cause of postoperatively newly occuring vertigo after CI. A transtympanic revision is a promising treatment option in cases of post-operative dizziness. Intoduction: A well-known and frequently reported complication after cochlear implantation is the appearance of postoperative vertigo symptoms. The aim of the present study was to observe if the postoperatively new occurrence of vertigo can be treated by resealing of the round window patch after cochlear implantation. A retrospective analysis revealed that 10 patients underwent revision surgery transtympanally. Vertigo was assessed preoperatively and directly postoperatively and after 6 month after revision surgery by using the Dizziness Handycap Inventory (DHI). The most common symptom was rotating vertigo. A spontanous nystagmus was seen in four cases. No nystagmus was found after the revision surgery. In three cases, the onset of dizziness was associated with an event (sneezing, otitis media, climbing a mountain). A preoperative CT showed insuspectible results in seven patients but revealed pathologies two patients. Vertigo was improved significantly in six patients, and three of them were symptom-free.

  5. Speech feature discrimination in deaf children following cochlear implantation

    Science.gov (United States)

    Bergeson, Tonya R.; Pisoni, David B.; Kirk, Karen Iler

    2002-05-01

    Speech feature discrimination is a fundamental perceptual skill that is often assumed to underlie word recognition and sentence comprehension performance. To investigate the development of speech feature discrimination in deaf children with cochlear implants, we conducted a retrospective analysis of results from the Minimal Pairs Test (Robbins et al., 1988) selected from patients enrolled in a longitudinal study of speech perception and language development. The MP test uses a 2AFC procedure in which children hear a word and select one of two pictures (bat-pat). All 43 children were prelingually deafened, received a cochlear implant before 6 years of age or between ages 6 and 9, and used either oral or total communication. Children were tested once every 6 months to 1 year for 7 years; not all children were tested at each interval. By 2 years postimplant, the majority of these children achieved near-ceiling levels of discrimination performance for vowel height, vowel place, and consonant manner. Most of the children also achieved plateaus but did not reach ceiling performance for consonant place and voicing. The relationship between speech feature discrimination, spoken word recognition, and sentence comprehension will be discussed. [Work supported by NIH/NIDCD Research Grant No. R01DC00064 and NIH/NIDCD Training Grant No. T32DC00012.

  6. PCB exposure and cochlear function at age 6 years.

    Science.gov (United States)

    Palkovičová Murínová, Ľubica; Moleti, Arturo; Sisto, Renata; Wimmerová, Soňa; Jusko, Todd A; Tihányi, Juraj; Jurečková, Dana; Kováč, Ján; Koštiaková, Vladimíra; Drobná, Beata; Trnovec, Tomáš

    2016-11-01

    Epidemiological studies have documented adverse associations between exposure to polychlorinated biphenyls (PCBs) and otological outcomes. Previously, we documented decreased distortion product otoacoustic emission (DPOAE) levels in children exposed to PCBs, up to the age of 45 months, amongst a cohort of children in eastern Slovakia. The objective of the present study is to evaluate cochlear dysfunction at 72 months of age in 214 children from this same cohort and to compare the otoacoustic test sensitivity to that of pure tone audiometry (PTA). The association between DPOAE, PTA, and PCBs was estimated by means of multivariate ANOVA (MANOVA) and linear regression models. ROC curves were computed to estimate the DPOAE-test power in children. The DPOAE level at 72 months was related to PCB-153 serum levels. The DPOAE Input/Output function test at mid-frequency (2kHz) has shown instead nonmonotonic dependence on PCB exposure, for the left ears of children, over the whole growth curve. No significant association was found between PTA hearing levels and PCB-153 concentration. High diagnostic power of the DPOAE-test was found in children, similar to that found by the same authors in adults. In conclusions the DPOAE-PCB correlation obtained at 72 months is similar to that at 45 months suggesting a permanent and stable ototoxic effect of the PCB exposure. The lack of statistical significance of the PCB-PTA correlation suggests that DPOAEs are sensitive biomarkers of cochlear damage. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Implicit sequence learning in deaf children with cochlear implants.

    Science.gov (United States)

    Conway, Christopher M; Pisoni, David B; Anaya, Esperanza M; Karpicke, Jennifer; Henning, Shirley C

    2011-01-01

    Deaf children with cochlear implants (CIs) represent an intriguing opportunity to study neurocognitive plasticity and reorganization when sound is introduced following a period of auditory deprivation early in development. Although it is common to consider deafness as affecting hearing alone, it may be the case that auditory deprivation leads to more global changes in neurocognitive function. In this paper, we investigate implicit sequence learning abilities in deaf children with CIs using a novel task that measured learning through improvement to immediate serial recall for statistically consistent visual sequences. The results demonstrated two key findings. First, the deaf children with CIs showed disturbances in their visual sequence learning abilities relative to the typically developing normal-hearing children. Second, sequence learning was significantly correlated with a standardized measure of language outcome in the CI children. These findings suggest that a period of auditory deprivation has secondary effects related to general sequencing deficits, and that disturbances in sequence learning may at least partially explain why some deaf children still struggle with language following cochlear implantation. © 2010 Blackwell Publishing Ltd.

  8. Social amplification of risk: An empirical study

    International Nuclear Information System (INIS)

    Burns, W.; Slovic, P.; Kasperson, R.; Kasperson, J.; Renn, O.; Emani, S.

    1990-09-01

    The social amplification of risk is a theoretical framework that addresses an important deficiency of formal risk assessment methods and procedures. Typically assessments of risk from technological mishaps have been based upon the expected number of people who could be killed or injured or the amount of property that might be damaged. The diverse and consequential impacts that followed in the aftermath of the Three Mile Island accident make it clear that risk assessments that exclude the role of public perceptions of risk will greatly underestimate the potential costs of certain types of hazards. The accident at Three Mile Island produced no direct fatalities and few, if any, expected deaths due to cancer, yet few other accidents in history have had such costly societal impacts. The experience of amplified impacts argues for the development of a broadened theoretical and methodological perspective capable of integrating technical assessment of risk with public perceptions. This report presents the results to date in an ongoing research effort to better understand the complex processes by which adverse events produce impacts. In particular this research attempts to construct a framework that can account for those events that have produced, or are capable of producing, greater societal impacts than would be forecast by traditional risk assessment methods. This study demonstrates that the social amplification of risk involves interactions between sophisticated technological hazards, public and private institutions, and subtle individual and public perceptions and behaviors. These factors, and the variables underlying the intricate processes of social amplification that occur in modern society, are not fully defined and clarified in this report. 19 refs., 9 figs., 10 tabs

  9. Multistage Force Amplification of Piezoelectric Stacks

    Science.gov (United States)

    Xu, Tian-Bing (Inventor); Siochi, Emilie J. (Inventor); Zuo, Lei (Inventor); Jiang, Xiaoning (Inventor); Kang, Jin Ho (Inventor)

    2015-01-01

    Embodiments of the disclosure include an apparatus and methods for using a piezoelectric device, that includes an outer flextensional casing, a first cell and a last cell serially coupled to each other and coupled to the outer flextensional casing such that each cell having a flextensional cell structure and each cell receives an input force and provides an output force that is amplified based on the input force. The apparatus further includes a piezoelectric stack coupled to each cell such that the piezoelectric stack of each cell provides piezoelectric energy based on the output force for each cell. Further, the last cell receives an input force that is the output force from the first cell and the last cell provides an output apparatus force In addition, the piezoelectric energy harvested is based on the output apparatus force. Moreover, the apparatus provides displacement based on the output apparatus force.

  10. Gas amplification properties of GEM foils

    International Nuclear Information System (INIS)

    Beck, Jeannine

    2009-01-01

    In the framework of the detector concept International Linear Detector for the future accelerator project International Linear Collider, in which electrons and positrons at c. m. energies of 500 GeV are brought to collision, a time projection chamber shall be applied as central track detector. By the application of such a chamber as track detector a three-dimensional reconstruction of the track points is possible. If a particle passes the gas volume within the chamber it ionizises single gas atoms and the arising electrons move after the amplification in the GEM arrangement to the anode, so that a two-dimensional projection of the particle track is possible. The third dimension is calculated from the drift time of the electrons. The advances of this readout system consist therein that a better position resolution than by a multiwire proportional chamber is reached and the back-drifting ions can be strongly suppressed. Aim of this thesis are studies for a GEM module, which shall be used in a large TPC prototype. Concerning different requirements it is valid to compare different GEMs in order to can meet an optimal choice. In a small prototype present at DESY measurements for the acquisition of GEM-describing parameters were performed. The taking into operation of the test TPC was part of this thesis. Tracks were generated by a radioactive source, by means of which the gas amplification was determined. With the measurement arrangement gas-amplifier foils of different kind were compared in view of their amplification properties and their energy resolution power and systematically studied. Five different GEM performances were studied in the test TPC. These foils differ in their geometrical classification parameters, the fabrication process, or the materials. The GEMs produced at CERN possess in comparison with GEMs of the Japanese firm SciEnergy and a GEM of the US-American firm Tech-Etch the best amplification and resolution properties. Furthermore a new GEM framing

  11. Amplification Effects and Unconventional Monetary Policies

    Directory of Open Access Journals (Sweden)

    Cécile BASTIDON GILLES

    2012-02-01

    Full Text Available Global financial crises trigger off amplification effects, which allow relatively small shocks to propagate through the whole financial system. For this reason, the range of Central banks policies is now widening beyond conventional monetary policies and lending of last resort. The aim of this paper is to establish a rule for this practice. The model is based on the formalization of funding conditions in various types of markets. We conduct a comprehensive analysis of the “unconventional monetary policies”, and especially quantify government bonds purchases by the Central bank.

  12. Amplification of curvature perturbations in cyclic cosmology

    International Nuclear Information System (INIS)

    Zhang Jun; Liu Zhiguo; Piao Yunsong

    2010-01-01

    We analytically and numerically show that through the cycles with nonsingular bounce, the amplitude of curvature perturbation on a large scale will be amplified and the power spectrum will redden. In some sense, this amplification will eventually destroy the homogeneity of the background, which will lead to the ultimate end of cycles of the global universe. We argue that for the model with increasing cycles, it might be possible that a fissiparous multiverse will emerge after one or several cycles, in which the cycles will continue only at corresponding local regions.

  13. Parametric Amplification of Gravitational Fluctuations during Reheating

    International Nuclear Information System (INIS)

    Finelli, F.; Brandenberger, R.; Finelli, F.

    1999-01-01

    Cosmological perturbations can undergo amplification by parametric resonance during preheating even on scales larger than the Hubble radius, without violating causality. A unified description of gravitational and matter fluctuations is crucial to determine the strength of the instability. To extract specific signatures of the oscillating inflaton field during reheating, it is essential to focus on a variable describing metric fluctuations which is constant in the standard analyses of inflation. For a massive inflaton without self-coupling, we find no additional growth of superhorizon modes during reheating beyond the usual predictions. For a massless self-coupled inflaton, there is a sub-Hubble scale resonance. copyright 1999 The American Physical Society

  14. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25.

    Science.gov (United States)

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-11-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.

  15. An aptasensor for staphylococcus aureus based on nicking enzyme amplification reaction and rolling circle amplification.

    Science.gov (United States)

    Xu, Jingguo; Guo, Jia; Maina, Sarah Wanjiku; Yang, Yumeng; Hu, Yimin; Li, Xuanxuan; Qiu, Jiarong; Xin, Zhihong

    2018-05-15

    An ultra-sensitive aptamer-based biosensor for the detection of staphylococcus aureus was established by adopting the nicking enzyme amplification reaction (NEAR) and the rolling circle amplification (RCA) technologies. Aptamer-probe (AP), containing an aptamer and a probe sequence, was developed to act as the recognition unit of the biosensor, which was specifically bound to S. aureus. The probe was released from AP and initiated into the subsequent DNA amplification reactions where S. aureus was present, converting the detection of S. aureus to the investigation of probe oligonucleotide. The RCA amplification products contained a G-quadruplex motif and formed a three dimensional structure in presence of hemin. The G4/hemin complex showed horseradish peroxidase (HRP)-mimic activity and catalyzed the chemiluminescence reaction of luminol mediated by H 2 O 2 . The results showed that the established biosensor could detect S. aureus specifically with a good linear correlation at 5-10 4  CFU/mL. The signal values based on NEAR-RCA two-step cycle were boosted acutely, much higher than that relied on one-cycle magnification. The limit of detection (LoD) was determined to be as low as 5 CFU/mL. The established aptasensor exhibited a good discrimination of living against dead S. aureus, and can be applied to detect S. aureus in the food industry. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Communication between cochlear perilymph and cerebrospinal fluid through the cochlear modiolus visualized after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Iwano, Shingo; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Intratympanic injection of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) has been reported as a procedure to visualize endolymphatic hydrops of Meniere's disease. We frequently noted that cerebrospinal fluid (CSF) in the internal auditory canal (IAC) was also enhanced after this procedure. The purpose of this study was to evaluate how frequently this occurs and to investigate the specific features of patients who lack this communication. A total of 25 patients with clinically suspected endolymphatic hydrops underwent the procedure. After 24 h, three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) and 3D constructive interference in steady state (3D-CISS) were performed. The presence of contrast enhancement in the CSF space of the fundus of the IAC was evaluated. The contrast ratio between CSF of the IAC fundus and cerebellar white matter on the injected side was 1.49±0.65, and that of the noninjected side was 0.32±0.16 (P<0.01). Enhancement of the CSF space in the IAC fundus was seen in all but two subjects: one had enlarged endolymphatic duct and sac syndrome (EEDS), and the other had cochlear nerve agenesis. In these two patients, the cochlear modiolus seemed to be normal. Intratympanic Gd-DTPA administration can reveal permeability of the modiolus and might facilitate evaluation of functional abnormalities of the modiolus not detected by conventional imaging tests. (author)

  17. C-MET overexpression and amplification in gliomas.

    Science.gov (United States)

    Kwak, Yoonjin; Kim, Seong-Ik; Park, Chul-Kee; Paek, Sun Ha; Lee, Soon-Tae; Park, Sung-Hye

    2015-01-01

    We investigated c-Met overexpression and MET gene amplification in gliomas to determine their incidence and prognostic significance. c-Met immunohistochemistry and MET gene fluorescence in situ hybridization were carried out on tissue microarrays from 250 patients with gliomas (137 grade IV GBMs and 113 grade II and III diffuse gliomas). Clinicopathological features of these cases were reviewed. c-Met overexpression and MET gene amplification were detected in 13.1% and 5.1% of the GBMs, respectively. All the MET-amplified cases showed c-Met overexpression, but MET amplification was not always concordant with c-Met overexpression. None of grade II and III gliomas demonstrated c-Met overexpression or MET gene amplification. Mean survival of the GBM patients with MET amplification was not significantly different from patients without MET amplification (P=0.155). However, GBM patients with c-Met overexpression survived longer than patients without c-Met overexpression (P=0.035). Although MET amplification was not related to poor GBM prognosis, it is partially associated with the aggressiveness of gliomas, as MET amplification was found only in grade IV, not in grade II and III gliomas. We suggest that MET inhibitor therapy may be beneficial in about 5% GBMs, which was the incidence of MET gene amplification found in the patients included in this study.

  18. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  19. Systematic review of compound action potentials as predictors for cochlear implant performance

    NARCIS (Netherlands)

    van Eijl, Ruben H M; Buitenhuis, Patrick J.; Stegeman, Inge; Klis, Sjaak F L; Grolman, Wilko

    2017-01-01

    Objectives/Hypothesis: The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically

  20. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  1. Significant regional differences in Denmark in outcome after cochlear implants in children

    DEFF Research Database (Denmark)

    Percy-Smith, Lone; Busch, Georg Walter; Sandahl, Minna

    2012-01-01

    The objectives of the present study were to study regional differences in outcome for a paediatric cochlear implant (CI) population after the introduction of universal neonatal hearing screening (UNHS) and bilateral implantation in Denmark....

  2. MRI of the labyrinth with volume rendering for cochlear implants candidates

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Harada, Kuniaki; Shirase, Ryuji; Suzuki, Junpei; Nagahama, Hiroshi

    2009-01-01

    We demonstrated three-dimensional models of the labyrinth by volume rendering (VR) in preoperative assessment for cochlear implantation. MRI data sets were acquired in selected subjects using three-dimensional-fast spin echo sequences (3D-FSE). We produced the three-dimensional models of the labyrinth from axial heavily T2-weighted images. The three-dimensional models distinguished the scala tympani and scala vestibuli and provided multidirectional images. The optimal threshold three-dimensional models clearly showed the focal region of signal loss in the cochlear turns (47.1%) and the presence of inner ear anomalies (17.3%) in our series of patients. This study was concluded that these three-dimensional models by VR provide the oto-surgeon with precise, detailed, and easily interpreted information about the cochlear turns for cochlear implants candidates. (author)

  3. Correlation between subjective and objective hearing tests after unilateral and bilateral cochlear implantation

    NARCIS (Netherlands)

    Ramakers, Geerte G.J.; Smulders, Yvette E.; Van Zon, Alice; van Zanten, Gijsbert A.; Grolman, Wilko; Stegeman, Inge

    2017-01-01

    Background: There are many methods for assessing hearing performance after cochlear implantation. Standard evaluations often encompass objective hearing tests only, while patients' subjective experiences gain importance in today's healthcare. The aim of the current study was to analyze the

  4. Cochlear Implantation and Single-sided Deafness: A Systematic Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cabral Junior, Francisco

    2015-07-01

    Full Text Available Introduction Current data show that binaural hearing is superior to unilateral hearing, specifically in the understanding of speech in noisy environments. Furthermore, unilateral hearing reduce onés ability to localize sound. Objectives This study provides a systematic review of recent studies to evaluate the outcomes of cochlear implantation in patients with single-sided deafness (SSD with regards to speech discrimination, sound localization and tinnitus suppression. Data Synthesis We performed a search in the PubMed, Cochrane Library and Lilacs databases to assess studies related to cochlear implantation in patients with unilateral deafness. After critical appraisal, eleven studies were selected for data extraction and analysis of demographic, study design and outcome data. Conclusion Although some studies have shown encouraging results on cochlear implantation and SSD, all fail to provide a high level of evidence. Larger studies are necessary to define the tangible benefits of cochlear implantation in patients with SSD.

  5. The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2014-01-01

    Full Text Available Introduction. We introduce a rating tool that objectively evaluates the skills of surgical trainees performing cochlear implant surgery. Methods. Seven residents and seven experts performed cochlear implant surgery sessions from mastoidectomy to cochleostomy on a standardized virtual reality temporal bone. A total of twenty-eight assessment videos were recorded and two consultant otolaryngologists evaluated the performance of each participant using these videos. Results. Interrater reliability was calculated using the intraclass correlation coefficient for both the global and checklist components of the assessment instrument. The overall agreement was high. The construct validity of this instrument was strongly supported by the significantly higher scores in the expert group for both components. Conclusion. Our results indicate that the proposed assessment tool for cochlear implant surgery is reliable, accurate, and easy to use. This instrument can thus be used to provide objective feedback on overall and task-specific competency in cochlear implantation.

  6. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  7. Use of Vaccines to Prevent Meningitis in Persons with Cochlear Implants

    Science.gov (United States)

    ... Before Traveling Related Links Vaccines & Immunizations Use of Vaccines to Prevent Meningitis in Persons with Cochlear Implants ... For More Information References One of the Recommended Vaccines by Disease What You Should Know People with ...

  8. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  9. Analysis of Changes in Auditory Nerve Signals Following Simulated Tinnitus for the Verification of Cochlear Model

    National Research Council Canada - National Science Library

    Yi, Y

    2001-01-01

    For an interpretation of the tinnitus phenomenon, reticular lamina which transmits energy in a cochlear was assumed as a mass and the components for the stiffness and control were added to the model...

  10. Deriving cochlear delays in humans using otoacoustic emissions and auditory evoked potentials

    DEFF Research Database (Denmark)

    Pigasse, Gilles

    A great deal of the processing of incoming sounds to the auditory system occurs within the cochlear. The organ of Corti within the cochlea has differing mechanical properties along its length that broadly gives rise to frequency selectivity. Its stiffness is at maximum at the base and decreases...... relation between frequency and travel time in the cochlea defines the cochlear delay. This delay is directly associated with the signal analysis occurring in the inner ear and is therefore of primary interest to get a better knowledge of this organ. It is possible to estimate the cochlear delay by direct...... and invasive techniques, but these disrupt the normal functioning of the cochlea and are usually conducted in animals. In order to obtain an estimate of the cochlear delay that is closer to the normally functioning human cochlea, the present project investigates non-invasive methods in normal hearing adults...

  11. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, Evi; Langereis, Margreet C.; Frijns, Johan H. M.; Free, Rolien H.; Goedegebure, Andre; Smits, Cas; Stokroos, Robert J.; Ariens-Meijer, Saskia A. M.; Mylanus, Emmanuel A. M.; Vermeulen, Anneke M.

    2016-01-01

    Background: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (Cl) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  12. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, E.; Langereis, M.C.; Frijns, J.H.; Free, R.H.; Goedegebure, A.; Smits, C.; Stokroos, R.J.; Ariens-Meijer, S.A.; Mylanus, E.A.M.; Vermeulen, A.M.J.

    2016-01-01

    BACKGROUND: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (CI) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  13. Will Outer Tropical Cyclone Size Change due to Anthropogenic Warming?

    Science.gov (United States)

    Schenkel, B. A.; Lin, N.; Chavas, D. R.; Vecchi, G. A.; Knutson, T. R.; Oppenheimer, M.

    2017-12-01

    Prior research has shown significant interbasin and intrabasin variability in outer tropical cyclone (TC) size. Moreover, outer TC size has even been shown to vary substantially over the lifetime of the majority of TCs. However, the factors responsible for both setting initial outer TC size and determining its evolution throughout the TC lifetime remain uncertain. Given these gaps in our physical understanding, there remains uncertainty in how outer TC size will change, if at all, due to anthropogenic warming. The present study seeks to quantify whether outer TC size will change significantly in response to anthropogenic warming using data from a high-resolution global climate model and a regional hurricane model. Similar to prior work, the outer TC size metric used in this study is the radius in which the azimuthal-mean surface azimuthal wind equals 8 m/s. The initial results from the high-resolution global climate model data suggest that the distribution of outer TC size shifts significantly towards larger values in each global TC basin during future climates, as revealed by 1) statistically significant increase of the median outer TC size by 5-10% (p<0.05) according to a 1,000-sample bootstrap resampling approach with replacement and 2) statistically significant differences between distributions of outer TC size from current and future climate simulations as shown using two-sample Kolmogorov Smirnov testing (p<<0.01). Additional analysis of the high-resolution global climate model data reveals that outer TC size does not uniformly increase within each basin in future climates, but rather shows substantial locational dependence. Future work will incorporate the regional mesoscale hurricane model data to help focus on identifying the source of the spatial variability in outer TC size increases within each basin during future climates and, more importantly, why outer TC size changes in response to anthropogenic warming.

  14. Quantum tomography enhanced through parametric amplification

    Science.gov (United States)

    Knyazev, E.; Spasibko, K. Yu; Chekhova, M. V.; Khalili, F. Ya

    2018-01-01

    Quantum tomography is the standard method of reconstructing the Wigner function of quantum states of light by means of balanced homodyne detection. The reconstruction quality strongly depends on the photodetectors quantum efficiency and other losses in the measurement setup. In this article we analyze in detail a protocol of enhanced quantum tomography, proposed by Leonhardt and Paul [1] which allows one to reduce the degrading effect of detection losses. It is based on phase-sensitive parametric amplification, with the phase of the amplified quadrature being scanned synchronously with the local oscillator phase. Although with sufficiently strong amplification the protocol enables overcoming any detection inefficiency, it was so far not implemented in the experiment, probably due to the losses in the amplifier. Here we discuss a possible proof-of-principle experiment with a traveling-wave parametric amplifier. We show that with the state-of-the-art optical elements, the protocol enables high fidelity tomographic reconstruction of bright non-classical states of light. We consider two examples: bright squeezed vacuum and squeezed single-photon state, with the latter being a non-Gaussian state and both strongly affected by the losses.

  15. Electronic cyclotron radiation amplification in thermonuclear plasmas

    International Nuclear Information System (INIS)

    Ziebell, L.F.

    1983-01-01

    The amplified emission of electron cyclotron radiation near the fundamental frequency from an inhomogeneous, anisotropic plasma slab is investigated in a linear theory. Plasma polarization effects are consistently included. Expressions are developed in the WKB approximation for emission in the ordinary and the extraordinary modes, for propagation perpendicular to the magnetic field. Numerical results are given for the extraordinary mode, for which effects are strongest. For the case of a loss-cone-type electron momentum distribution, it is shown that the amplification is sensitively dependent on the ratio of parallel-to-perpendicular temperature and on inhomogeneities in the magnetic field. The dependence of the amplification on the distribution is further investigated by considering superpositions of loss-cone and Maxwellian components. It is show that the presence of a Maxwellian component in general reduces the emission relative to the pure loss-cone case, and situations occur in which a layer in the slab very effectively absorbs all the radiation amplified elsewhere. A peculiar behaviour of the refractive index, which occurs in the transition from the pure loss-cone to the pure Maxwellian case, is discussed. (author)

  16. Detection of Bar Transgenic Sugarcane with a Rapid and Visual Loop-Mediated Isothermal Amplification Assay.

    Science.gov (United States)

    Zhou, Dinggang; Wang, Chunfeng; Li, Zhu; Chen, Yun; Gao, Shiwu; Guo, Jinlong; Lu, Wenying; Su, Yachun; Xu, Liping; Que, Youxiong

    2016-01-01

    Genetic engineering offers an attractive alternative in sugarcane breeding for increasing cane and sugar yields as well as disease and insect resistance. Bar transgenic sugarcane employing the herbicide tolerance is a useful agronomical trait in weed control. In this study, a loop-mediated isothermal amplification (LAMP) assay for rapid detection of the bar gene in transgenic sugarcane has been developed and evaluated. A set of six primers was designed for LAMP-based amplification of the bar gene. The LAMP reaction conditions were optimized as follows: 5.25 mM of Mg(2+), 6:1 ratio of inner vs. outer primer, and 6.0 U of Bst DNA polymerase in a reaction volume of 25.0 μL. The detection limit of the recombinant plasmid 1Ac0229 was as low as 10 copies in the developed LAMP, which was 10-fold higher sensitive than that of conventional PCR. In 100 putative transgenic lines, the bar gene was detected in 100/100 cases (100%) by LAMP and 97/100 cases (97%) by conventional PCR, respectively. In conclusion, the developed LAMP assay is visual, rapid, sensitive, reliable, and cost-effective for detection of the bar specific transgenic sugarcane.

  17. Detection of bar transgenic sugarcane with a rapid and visual loop-mediated isothermal amplification assay

    Directory of Open Access Journals (Sweden)

    Dinggang eZhou

    2016-03-01

    Full Text Available Genetic engineering offers an attractive alternative in sugarcane breeding for increasing cane and sugar yields as well as disease and insect resistance. Bar transgenic sugarcane employing the herbicide tolerance is a useful agronomical trait in weed control. In this study, a loop-mediated isothermal amplification (LAMP assay for rapid detection of the bar gene in transgenic sugarcane has been developed and evaluated. A set of six primers was designed for LAMP-based amplification of the bar gene. The LAMP reaction conditions were optimized as follows: 5.25 mM of Mg2+, 6:1 ratio of inner vs outer primer, and 6.0 U of Bst DNA polymerase in a reaction volume of 25.0 μL. The detection limit of the recombinant plasmid 1Ac0229 was as low as 10 copies in the developed LAMP, which was ten-fold higher sensitive than that of conventional PCR. In 100 putative transgenic lines, the bar gene was detected in 100/100 cases (100% by LAMP and 97/100 cases (97% by conventional PCR, respectively. In conclusion, the developed LAMP assay is visual, rapid, sensitive, reliable and cost-effective for detection of the bar specific transgenic sugarcane.

  18. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    Science.gov (United States)

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Cochlear ossification in patients with profound hearing loss following bacterial meningitis

    DEFF Research Database (Denmark)

    Caye-Thomasen, Per; Dam, Mikkel Seidelin; Omland, Silje Haukali

    2012-01-01

    Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification.......Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification....

  20. Surgical complications following cochlear implantation in adults based on a proposed reporting consensus

    DEFF Research Database (Denmark)

    Jeppesen, Jonas; Faber, Christian Emil

    2013-01-01

    Abstract Conclusion: The rate of severe complications was low and cochlear implantation is a relatively safe procedure. Standardization is crucial when reporting on cochlear implant complications to ensure comparability between studies. A consensus on the reporting of complications proposed by a ...... occurred following one implantation (0.3%). Transient chorda tympani syndrome (30.8%), vertigo/dizziness (29.5%) and tinnitus (4.9%) were the most frequent minor complications....

  1. Study of dynamic amplification factor of DEMO blanket caused by a gap at the supporting key

    International Nuclear Information System (INIS)

    Frosi, Paolo; Mazzone, Giuseppe

    2015-01-01

    Highlights: • With the preliminary hypothesis established, the dynamic displacements are not so high and the state of stress (not reported) does not exhibit large region with plastic strain. • The dynamic displacements show a certain dependency from the mesh adopted, and the geometry chosen. • The energy (kinetic or strain) of the whole structure gives useful information about the key behavior during impact. • In order to better understand the overall phenomenon other details (non-linear material, better evaluation of damping, other disruption rise-times and so on. - Abstract: Among the design activities of the in vessel components for DEMO promoted by European Fusion Development Agreement (EFDA) organization, this work deals with the gap required at the supporting keys of the blanket. Due to its higher operating temperatures compared to the vacuum vessel (VV) ones, this gap will increase during operation. The electro magnetic (EM) loads due to fast disruptions occur on a short time and might accelerate the blanket significantly before it touches the supporting keys, causing an impact of the blanket itself onto the keys. Depending on their stiffness, the EM loads with their short time scale could excite the structure's natural frequencies, causing dynamic amplification. Both phenomena (impact and dynamic amplification) can cause stresses in the structure significantly higher than the static ones. This work develops a finite element model of DEMO blanket to study its non-linear transient dynamic behavior under impact loadings. A VV sector, the ribs between the inner and outer VV, the backward manifolds and the supporting keys of the blanket have been modeled. The analyses have been performed with Abaqus [1] and Ansys [2] FEM codes focused on the displacements of the keys in their housing on the blanket. The dynamic amplification factor has been evaluated as the ratio of dynamic to static displacements in meaningful points of the structure for a growing gap

  2. Study of dynamic amplification factor of DEMO blanket caused by a gap at the supporting key

    Energy Technology Data Exchange (ETDEWEB)

    Frosi, Paolo, E-mail: paolo.frosi@enea.it; Mazzone, Giuseppe

    2015-10-15

    Highlights: • With the preliminary hypothesis established, the dynamic displacements are not so high and the state of stress (not reported) does not exhibit large region with plastic strain. • The dynamic displacements show a certain dependency from the mesh adopted, and the geometry chosen. • The energy (kinetic or strain) of the whole structure gives useful information about the key behavior during impact. • In order to better understand the overall phenomenon other details (non-linear material, better evaluation of damping, other disruption rise-times and so on. - Abstract: Among the design activities of the in vessel components for DEMO promoted by European Fusion Development Agreement (EFDA) organization, this work deals with the gap required at the supporting keys of the blanket. Due to its higher operating temperatures compared to the vacuum vessel (VV) ones, this gap will increase during operation. The electro magnetic (EM) loads due to fast disruptions occur on a short time and might accelerate the blanket significantly before it touches the supporting keys, causing an impact of the blanket itself onto the keys. Depending on their stiffness, the EM loads with their short time scale could excite the structure's natural frequencies, causing dynamic amplification. Both phenomena (impact and dynamic amplification) can cause stresses in the structure significantly higher than the static ones. This work develops a finite element model of DEMO blanket to study its non-linear transient dynamic behavior under impact loadings. A VV sector, the ribs between the inner and outer VV, the backward manifolds and the supporting keys of the blanket have been modeled. The analyses have been performed with Abaqus [1] and Ansys [2] FEM codes focused on the displacements of the keys in their housing on the blanket. The dynamic amplification factor has been evaluated as the ratio of dynamic to static displacements in meaningful points of the structure for a growing

  3. Three challenges for future research on cochlear implants

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2017-12-01

    Full Text Available Cochlear implants (CIs often work very well for many children and adults with profound sensorineural (SNHL hearing loss. Unfortunately, while many CI patients display substantial benefits in recognizing speech and understanding spoken language following cochlear implantation, a large number of patients achieve poor outcomes. Understanding and explaining the reasons for poor outcomes following implantation is a very challenging research problem that has received little attention despite the pressing clinical significance. In this paper, we discuss three challenges for future research on CIs. First, we consider the issue of individual differences and variability in outcomes following implantation. At the present time, we still do not have a complete and satisfactory account of the causal underlying factors that are responsible for the enormous individual differences and variability in outcomes. Second, we discuss issues related to the lack of preimplant predictors of outcomes. Very little prospective research has been carried out on the development of preimplant predictors that can be used to reliably identify CI candidates who may be at high risk for a poor outcome following implantation. Other than conventional demographics and hearing history, there are no prognostic tools available to predict speech recognition outcomes after implantation. Finally, we discuss the third challenge — what to do with a CI-user who has a poor outcome. We suggest that new research efforts need to be devoted to studying this neglected clinical population in greater depth to find out why they are doing poorly with their CI and what novel interventions and treatments can be developed to improve their speech recognition outcomes. Using these three challenges as objectives for future research on CIs, we suggest that the field needs to adopt a new narrative grounded in theory and methods from Cognitive Hearing Science and information processing theory. Without knowing

  4. Coding strategies for cochlear implants under adverse environments

    Science.gov (United States)

    Tahmina, Qudsia

    Cochlear implants are electronic prosthetic devices that restores partial hearing in patients with severe to profound hearing loss. Although most coding strategies have significantly improved the perception of speech in quite listening conditions, there remains limitations on speech perception under adverse environments such as in background noise, reverberation and band-limited channels, and we propose strategies that improve the intelligibility of speech transmitted over the telephone networks, reverberated speech and speech in the presence of background noise. For telephone processed speech, we propose to examine the effects of adding low-frequency and high- frequency information to the band-limited telephone speech. Four listening conditions were designed to simulate the receiving frequency characteristics of telephone handsets. Results indicated improvement in cochlear implant and bimodal listening when telephone speech was augmented with high frequency information and therefore this study provides support for design of algorithms to extend the bandwidth towards higher frequencies. The results also indicated added benefit from hearing aids for bimodal listeners in all four types of listening conditions. Speech understanding in acoustically reverberant environments is always a difficult task for hearing impaired listeners. Reverberated sounds consists of direct sound, early reflections and late reflections. Late reflections are known to be detrimental to speech intelligibility. In this study, we propose a reverberation suppression strategy based on spectral subtraction to suppress the reverberant energies from late reflections. Results from listening tests for two reverberant conditions (RT60 = 0.3s and 1.0s) indicated significant improvement when stimuli was processed with SS strategy. The proposed strategy operates with little to no prior information on the signal and the room characteristics and therefore, can potentially be implemented in real-time CI

  5. Impact of socioeconomic factors on paediatric cochlear implant outcomes.

    Science.gov (United States)

    Sharma, Shalabh; Bhatia, Khyati; Singh, Satinder; Lahiri, Asish Kumar; Aggarwal, Asha

    2017-11-01

    The study was aimed at evaluating the impact of certain socioeconomic factors such as family income, level of parents' education, distance between the child's home and auditory verbal therapy clinic, and age of the child at implantation on postoperative cochlear implant outcomes. Children suffering from congenital bilateral profound sensorineural hearing loss and a chronologic age of 4 years or younger at the time of implantation were included in the study. Children who were able to complete a prescribed period of a 1-year follow-up were included in the study. These children underwent cochlear implantation surgery, and their postoperative outcomes were measured and documented using categories of auditory perception (CAP), meaningful auditory integration (MAIS), and speech intelligibility rating (SIR) scores. Children were divided into three groups based on the level of parental education, family income, and distance of their home from the rehabilitation-- auditory verbal therapy clinic. A total of 180 children were studied. The age at implantation had a significant impact on the postoperative outcomes, with an inverse correlation. The younger the child's age at the time of implantation, the better were the postoperative outcomes. However, there were no significant differences among the CAP, MAIS, and SIR scores and each of the three subgroups. Children from families with an annual income of less than $7,500, between $7,500 and $15,000, and more than $15,000 performed equally well, except for significantly higher SIR scores in children with family incomes more than $15,000. Children with of parents who had attended high school or possessed a bachelor's or Master's master's degree had similar scores, with no significant difference. Also, distance from the auditory verbal therapy clinic failed to have any significantimpact on a child's performance. These results have been variable, similar to those of previously published studies. A few of the earlier studies

  6. Learning and Memory Processes Following Cochlear Implantation:The Missing Piece of the Puzzle

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2016-04-01

    Full Text Available At the present time, there is no question that cochlear implants work and often work very well in quiet listening conditions for many profoundly deaf children and adults. The speech and language outcomes data published over the last two decades document quite extensively the clinically significant benefits of cochlear implants. Although there now is a large body of evidence supporting the efficacy of cochlear implants as a medical intervention for profound hearing loss in both children and adults, there still remain a number of challenging unresolved clinical and theoretical issues that deal with the effectiveness of cochlear implants in individual patients that have not yet been successfully resolved. In this paper, we review recent findings on learning and memory, two central topics in the field of cognition that have been seriously neglected in research on cochlear implants. Our research findings on sequence learning, memory and organization processes, and retrieval strategies used in verbal learning and memory of categorized word lists suggests that basic domain-general learning abilities may be the missing piece of the puzzle in terms of understanding the cognitive factors that underlie the enormous individual differences and variability routinely observed in speech and language outcomes following cochlear implantation.

  7. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Kawai, Hisashi; Naganawa, Shinji; Ishihara, Shunichi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement. We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above. The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09±1.23, and that on the non-injected side was -0.48±0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually. Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy. (author)

  8. Phonological working memory and its relationship with language abilities in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Fatemeh Haresabadi

    2014-12-01

    Full Text Available Background and Aim: Many studies have demonstrated a close relationship between phonological working memory and language abilities in normal children and children with language developmental disorders, such as those with cochlear implants. A review of these studies would clarify communication and learning in such children and provide more comprehensive information regarding their education and treatment. In this study, the characteristics of phonological working memory and its relationship with language abilities in children with cochlear implants was examined.Recent Findings: In this study, the authors studied the characteristics of phonological working memory and its relationship with language abilities of children with cochlear implants. These studies showed that in addition to demographic variables, phonological working memory is a factor that affects language development in children with cochlear implants. Children with cochlear implants typically have a shorter memory span.Conclusion: It is thought that the deficiency in primary auditory sensory input and language stimulation caused by difficulties in the processing and rehearsal of auditory information in phonological working memory is the main cause of the short memory span in such children. Conversely, phonological working memory problems may have adverse effects on the language abilities in such children. Therefore, to provide comprehensive and appropriate treatment for children with cochlear implants, the reciprocal relationship between language abilities and phonological working memory should be considered.

  9. Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2011-10-01

    Full Text Available Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf child's language development, this study evaluates the effect of different variables on child's language performance. Methods: 45 cochlear implanted children were tested, all of whom had used the device for at least 2 years. In order to evaluate the children, the NEWSHA test which is fitted for Persian speaking children was performed and language development of the children was compared through stepwise discriminant analysis. Results: After evaluation of the effect of different variables like child's age of implantation, participating in rehabilitation classes, parent's cooperation and their level of education, we came to a conclusion that the child's age of implantation and rehabilitation program significantly develop the child's language performance. Discussion: The value of cochlear implant in improvement of deaf children in speech, language perception, production and comprehension is confirmed by different studies which have been done on cochlear implanted children. Also, the present study indicates that language development in cochlear implanted children is highly related to their age of implantation and rehabilitation program.

  10. Electrophysiological evidence for altered visual, but not auditory, selective attention in adolescent cochlear implant users.

    Science.gov (United States)

    Harris, Jill; Kamke, Marc R

    2014-11-01

    Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Conductive component after cochlear implantation in patients with residual hearing conservation.

    Science.gov (United States)

    Chole, Richard A; Hullar, Timothy E; Potts, Lisa G

    2014-12-01

    Changes in auditory thresholds following cochlear implantation are generally assumed to be due to damage to neural elements. Theoretical studies have suggested that placement of a cochlear implant can cause a conductive hearing loss. Identification of a conductive component following cochlear implantation could guide improvements in surgical techniques or device designs. The purpose of this study is to characterize new-onset conductive hearing losses after cochlear implantation. In a prospective study, air- and bone-conduction audiometric testing were completed on cochlear implant recipients. An air-bone gap equal to or greater than 15 dB HL at 2 frequencies determined the presence of a conductive component. Of the 32 patients with preoperative bone-conduction hearing, 4 patients had a new-onset conductive component resulting in a mixed hearing loss, with air-conduction thresholds ranging from moderate to profound and an average air-bone gap of 30 dB HL. One had been implanted through the round window, 2 had an extended round window, and 1 had a separate cochleostomy. Loss of residual hearing following cochlear implantation may be due in part to a conductive component. Identifying the mechanism for this conductive component may help minimize hearing loss. Postoperative hearing evaluation should measure both air- and bone-conduction thresholds.

  12. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  13. Hair Barrette Induced Cochlear Implant Receiver Stimulator Site Infection with Extrusion

    Directory of Open Access Journals (Sweden)

    Trung N. Le

    2015-01-01

    Full Text Available Background. Cochlear implant infections and extrusion are uncommon but potentially devastating complications. Recent literature suggests conservative management can be employed. Local measures inclusive of aggressive surgical debridement with vascularized flaps and parenteral antibiotics represent a viable option and often permit device salvage. However, explantation should be considered if there is evidence of systemic, intracranial, or intractable infection. Method. A Case report and literature review. Case Report. This case illustrates a complicated local wound infection associated with cochlear implantation due to transcutaneous adherence of a ferrous hair barrette to a cochlear implant magnet. Reconstruction of computed tomography (CT data with 3D volume rendering significantly improved the value of the images and facilitated patient counseling as well as operative planning. Conclusion. Cochlear implant infections can be associated with foreign bodies. CT images are beneficial in the evaluation of cochlear implant complications. 3D CT images provide a comprehensive view of the site of interest, displaying the relationship of the hardware to the skull and soft tissues, while minimizing associated artifacts. Cochlear implant patients should consider use of nonmetallic hair devices.

  14. Is there a best side for cochlear implants in post-lingual patients?

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Statistics of the outer radiation belt

    International Nuclear Information System (INIS)

    Rodgers, D.J.; Johnstone, A.D.

    1996-01-01

    The highly variable electron flux levels in the outer radiation belt come about by competition between time-dependent source and loss mechanisms. In order to identify some of the different mechanisms involved, we examine the statistics of the variability of fluxes at geostationary orbit. Data from the SEM-2 analyzer on Meteosat-3 and from GOES-7 are used. Correlation analysis is used to find time-delays between changes in flux at different energies. We see that low energy flux is added to this region during sub-storms and that higher energy fluxes appear after 2 or 3 days. Whilst the timescale for this process is brief compared to a complete cycle of the open-quote Recirculation close-quote energization process, it is consistent with the timescale of its final step endash outward radial diffusion. By isolating periods when no new injection of plasma occurs, we make an assessment of flux loss rates in a quiet magnetosphere. copyright 1996 American Institute of Physics

  16. Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of fasciolosis in sheep and its application under field conditions.

    Science.gov (United States)

    Martínez-Valladares, María; Rojo-Vázquez, Francisco Antonio

    2016-02-05

    Loop-mediated isothermal amplification (LAMP) is a very specific, efficient, and rapid gene amplification procedure in which the reaction can run at a constant temperature. In the current study we have developed a LAMP assay to improve the diagnosis of Fasciola spp. in the faeces of sheep. After the optimisation of the LAMP assay we have shown similar results between this technique and the standard PCR using the outer primers of the LAMP reaction. In both cases the limit of detection was 10 pg; also, the diagnosis of fasciolosis was confirmed during the first week post-infection in experimental infected sheep by both techniques. In eight naturally infected sheep, the infection with F. hepatica was confirmed in all animals before a treatment with triclabendazole and on day 30 post treatment in two sheep using the LAMP assay; however, when we carried out the standard PCR with the outer primers, the results before treatment were the same but on day 30 post-treatment the infection was only confirmed in one out of the two sheep. On the other hand, the standard PCR took around 3 h to obtain a result, comparing with 1 h and 10 min for the LAMP assay. The LAMP assay described here could be a good alternative to conventional diagnostic methods to detect F. hepatica in faeces since it solves the drawbacks of the standard PCR.

  17. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  18. Rate modulation detection thresholds for cochlear implant users.

    Science.gov (United States)

    Brochier, Tim; McKay, Colette; McDermott, Hugh

    2018-02-01

    The perception of temporal amplitude modulations is critical for speech understanding by cochlear implant (CI) users. The present study compared the ability of CI users to detect sinusoidal modulations of the electrical stimulation rate and current level, at different presentation levels (80% and 40% of the dynamic range) and modulation frequencies (10 and 100 Hz). Rate modulation detection thresholds (RMDTs) and amplitude modulation detection thresholds (AMDTs) were measured and compared to assess whether there was a perceptual advantage to either modulation method. Both RMDTs and AMDTs improved with increasing presentation level and decreasing modulation frequency. RMDTs and AMDTs were correlated, indicating that a common processing mechanism may underlie the perception of rate modulation and amplitude modulation, or that some subject-dependent factors affect both types of modulation detection.

  19. The rolling circle amplification and next generation sequencing ...

    African Journals Online (AJOL)

    Rolling circle amplification is a simple approach of enriching populations of single-stranded DNA plant begomovirus genomes (genus, Begomovirus; family, Geminiviridae). This is an innovative approach that utilizes the robustness of the bacteriophage phi29 DNA polymerase used in circle amplification, together with deep ...

  20. Amplification of Chirality in Hydrogen-Bonded Tetrarosette Helices

    NARCIS (Netherlands)

    Mateos timoneda, Miguel; Crego Calama, Mercedes; Reinhoudt, David

    2006-01-01

    The amplification of chirality in hydrogen-bonded tetrarosette assemblies under thermodynamic equilibrium is described. The extent of the chiral amplification obtained by means of “sergeants-and-soldiers” experiments depends only on the structure of the assembly and it is independent of the

  1. Centrosome Amplification Is Sufficient to Promote Spontaneous Tumorigenesis in Mammals

    NARCIS (Netherlands)

    Levine, Michelle S.; Bakker, Bjorn; Boeckx, Bram; Moyett, Julia; Lu, James; Vitre, Benjamin; Spierings, Diana C.; Lansdorp, Peter M.; Cleveland, Don W.; Lambrechts, Diether; Foijer, Floris; Holland, Andrew J.

    2017-01-01

    Centrosome amplification is a common feature of human tumors, but whether this is a cause or a consequence of cancer remains unclear. Here, we test the consequence of centrosome amplification by creating mice in which centrosome number can be chronically increased in the absence of additional

  2. Explanatory Model for Sound Amplification in a Stethoscope

    Science.gov (United States)

    Eshach, H.; Volfson, A.

    2015-01-01

    In the present paper we suggest an original physical explanatory model that explains the mechanism of the sound amplification process in a stethoscope. We discuss the amplification of a single pulse, a continuous wave of certain frequency, and finally we address the resonant frequencies. It is our belief that this model may provide students with…

  3. An enzymatic signal amplification system for calorimetric studies of cellobiohydrolases

    DEFF Research Database (Denmark)

    Murphy, Leigh; Baumann, Martin Johannes; Borch, Kim

    2010-01-01

    amplification method has been developed to measure even slow hydrolytically active enzymes such as cellobiohydrolases. This method is explained in detail for the amplification of the heat signal by more than 130 times by using glucose oxidase and catalase. The kinetics of this complex coupled reaction system...

  4. Chirped pulse amplification: Present and future

    International Nuclear Information System (INIS)

    Maine, P.; Strickland, D.; Pessot, M.; Squier, J.; Bado, P.; Mourou, G.; Harter, D.

    1988-01-01

    Short pulses with ultrahigh peak powers have been generated in Nd: glass and Alexandrite using the Chirped Pulse Amplification (CPA) technique. This technique has been successful in producing picosecond terawatt pulses with a table-top laser system. In the near future, CPA will be applied to large laser systems such as NOVA to produce petawatt pulses (1 kJ in a 1 ps pulse) with focused intensities exceeding 10/sup /plus/21/ W/cm 2 . These pulses will be associated with electric fields in excess of 100 e/a/sub o/ 2 and blackbody energy densities equivalent to 3 /times/ 10 10 J/cm 3 . This petawatt source will have important applications in x-ray laser research and will lead to fundamentally new experiments in atomic, nuclear, solid-state, plasma, and high-energy density physics. A review of present and future designs are discussed. 17 refs., 5 figs

  5. Raman amplification in optical communication systems

    DEFF Research Database (Denmark)

    Kjær, Rasmus

    2008-01-01

    Fiber Raman amplifiers are investigated with the purpose of identifying new applications and limitations for their use in optical communication systems. Three main topics are investigated, namely: New applications of dispersion compensating Raman amplifiers, the use Raman amplification to increase...... fiberbaserede Raman-forstærkere med henblik på at identificere både deres begrænsninger og nye anvendelsesmuligheder i optiske kommunikationssystemer. En numerisk forstærkermodel er blevet udviklet for bedre at forstå forstærkerens dynamik, dens gain- og støjbegrænsninger. Modellen bruges til at forudsige...... forstærkerens statiske og dynamiske egenskaber, og det eftervises at dens resultater er i god overensstemmelse med eksperimentelle forstærkermålinger. Dispersions-kompenserende fiber er på grund af sin store udbredelse og fiberens høje Raman gain effektivitet et meget velegnet Raman gain-medium. Tre nye...

  6. Pain Amplification Syndrome: A Biopsychosocial Approach.

    Science.gov (United States)

    Namerow, Lisa B; Kutner, Emily C; Wakefield, Emily C; Rzepski, Barbara R; Sahl, Robert A

    2016-08-01

    Pediatric neurologists frequently encounter patients who present with significant musculoskeletal pain that cannot be attributed to a specific injury or illness, which can often be defined as pain amplification syndrome (PAS). PAS in children and adolescents is the result of a heightened pain sensitivity pathway, which is intensified by significant biological, psychological, and social contributors. Appropriate assessment and multimodal intervention of PAS are crucial to treatment success, including neurology and behavioral health collaborative treatment plans to restore patient function and reduce pain perception. Pediatric neurologists are imperative in the identification of patients with PAS, providing the family assurance in diagnosis and validation of pain, and directing patients to the appropriate multidisciplinary treatment pathway. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Whole genome amplification in preimplantation genetic diagnosis*

    Science.gov (United States)

    Zheng, Ying-ming; Wang, Ning; Li, Lei; Jin, Fan

    2011-01-01

    Preimplantation genetic diagnosis (PGD) refers to a procedure for genetically analyzing embryos prior to implantation, improving the chance of conception for patients at high risk of transmitting specific inherited disorders. This method has been widely used for a large number of genetic disorders since the first successful application in the early 1990s. Polymerase chain reaction (PCR) and fluorescent in situ hybridization (FISH) are the two main methods in PGD, but there are some inevitable shortcomings limiting the scope of genetic diagnosis. Fortunately, different whole genome amplification (WGA) techniques have been developed to overcome these problems. Sufficient DNA can be amplified and multiple tasks which need abundant DNA can be performed. Moreover, WGA products can be analyzed as a template for multi-loci and multi-gene during the subsequent DNA analysis. In this review, we will focus on the currently available WGA techniques and their applications, as well as the new technical trends from WGA products. PMID:21194180

  8. Controlled Microwave Heating Accelerates Rolling Circle Amplification.

    Science.gov (United States)

    Yoshimura, Takeo; Suzuki, Takamasa; Mineki, Shigeru; Ohuchi, Shokichi

    2015-01-01

    Rolling circle amplification (RCA) generates single-stranded DNAs or RNA, and the diverse applications of this isothermal technique range from the sensitive detection of nucleic acids to analysis of single nucleotide polymorphisms. Microwave chemistry is widely applied to increase reaction rate as well as product yield and purity. The objectives of the present research were to apply microwave heating to RCA and indicate factors that contribute to the microwave selective heating effect. The microwave reaction temperature was strictly controlled using a microwave applicator optimized for enzymatic-scale reactions. Here, we showed that microwave-assisted RCA reactions catalyzed by either of the four thermostable DNA polymerases were accelerated over 4-folds compared with conventional RCA. Furthermore, the temperatures of the individual buffer components were specifically influenced by microwave heating. We concluded that microwave heating accelerated isothermal RCA of DNA because of the differential heating mechanisms of microwaves on the temperatures of reaction components, although the overall reaction temperatures were the same.

  9. Social and political amplification of technological hazards

    International Nuclear Information System (INIS)

    Ibitayo, Olurominiyi O.; Mushkatel, Alvin; Pijawka, K. David

    2004-01-01

    Using an industrial explosion in Henderson, Nevada, as a case study, this paper examines three main issues: the efficacy of a technological hazard event in amplifying otherwise latent issues, the extent to which the hazard event can serve as a focusing event for substantive local and state policy initiatives, and the effect of fragmentation of political authority in managing technological hazards. The findings indicate that the explosion amplified several public safety issues and galvanized the public into pressing for major policy initiatives. However, notwithstanding the amplification of several otherwise latent issues, and the flurry of activities by the state and local governments, the hazard event did not seem to be an effective focusing event or trigger mechanism for substantive state and local policy initiatives. In addition, the study provides evidence of the need for a stronger nexus between political authority, land-use planning and technological hazard management

  10. Resistive wall modes and error field amplification

    International Nuclear Information System (INIS)

    Boozer, Allen H.

    2003-01-01

    Resistive wall modes and the rapid damping of plasma rotation by the amplification of magnetic field errors are related physical phenomena that affect the performance of the advanced tokamak and spherical torus plasma confinement devices. Elements of our understanding of these phenomena and the code that is used to design the major experimental facilities are based on the electrical circuit representation of the response of the plasma to perturbations. Although the circuit representation of the plasma may seem heuristic, this representation can be rigorously obtained using Maxwell's equations and linearity for plasmas that evolve on a disparate time scale from that of external currents. These and related results are derived. In addition methods are given for finding the plasma information that the circuit representation requires using post-processors for codes that calculate perturbed plasma equilibria

  11. Scintillation light detectors with Neganov Luke amplification

    Science.gov (United States)

    Isaila, C.; Boslau, O.; Coppi, C.; Feilitzsch, F. v.; Goldstraß, P.; Jagemann, T.; Jochum, J.; Kemmer, J.; Lachenmaier, T.; Lanfranchi, J.-C.; Pahlke, A.; Potzel, W.; Rau, W.; Stark, M.; Wernicke, D.; Westphal, W.

    2006-04-01

    For an active suppression of the gamma and electron background in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST) dark matter experiment both phonons and scintillation light generated in a CaWO 4 crystal are detected simultaneously. The phonon signal is read out by a transition edge sensor (TES) on the CaWO 4 crystal. For light detection a silicon absorber equipped with a TES is employed. An efficient background discrimination requires very sensitive light detectors. The threshold can be improved by applying an electric field to the silicon crystal leading to an amplification of the thermal signal due to the Neganov-Luke effect. Measurements showing the improved sensitivity of the light detectors as well as future steps for reducing the observed extra noise will be presented.

  12. Raman Amplification with a Flying Focus

    Science.gov (United States)

    Turnbull, D.; Bucht, S.; Davies, A.; Haberberger, D.; Kessler, T.; Shaw, J. L.; Froula, D. H.

    2018-01-01

    We propose a new laser amplifier scheme utilizing stimulated Raman scattering in plasma in conjunction with a "flying focus"—a chromatic focusing system combined with a chirped pump beam that provides spatiotemporal control over the pump's focal spot. Pump intensity isosurfaces are made to propagate at v =-c so as to be in sync with the injected counterpropagating seed pulse. By setting the pump intensity in the interaction region to be just above the ionization threshold of the background gas, an ionization wave is produced that travels at a fixed distance ahead of the seed. Simulations show that this will make it possible to optimize the plasma temperature and mitigate many of the issues that are known to have impacted previous Raman amplification experiments, in particular, the growth of precursors.

  13. Protein Misfolding Cyclic Amplification of Infectious Prions.

    Science.gov (United States)

    Moda, Fabio

    2017-01-01

    Transmissible spongiform encephalopathies, or prion diseases, are a group of incurable disorders caused by the accumulation of an abnormally folded prion protein (PrP Sc ) in the brain. According to the "protein-only" hypothesis, PrP Sc is the infectious agent able to propagate the disease by acting as a template for the conversion of the correctly folded prion protein (PrP C ) into the pathological isoform. Recently, the mechanism of PrP C conversion has been mimicked in vitro using an innovative technique named protein misfolding cyclic amplification (PMCA). This technology represents a great tool for studying diverse aspects of prion biology in the field of basic research and diagnosis. Moreover, PMCA can be expanded for the study of the misfolding process associated to other neurodegenerative diseases, including Alzheimer's disease, Parkinson's disease, and frontotemporal lobar degeneration. © 2017 Elsevier Inc. All rights reserved.

  14. COCHLEAR IMPLANT AND AUTISM SPECTRUM DISORDER: THE EXPERIENCE OF MOTHERS

    Directory of Open Access Journals (Sweden)

    Carolina Ruiz Longato-Morais

    2017-12-01

    Full Text Available Cochlear implant (CI, a device surgically implanted in the ear, may be indicated for people with severe or profound hearing loss (HI. A significant number of children are affected by HI and other comorbidities, including Autism Spectrum Disorder (ASD. The objective of this study was to understand the experience of mothers of children with CI and diagnosis of ASD. The study had qualitative nature and the method used was phenomenological investigation, which consists in the apprehension of the phenomenon as it manifests itself to the person who experiences it. Six mothers of children with CI and diagnosis of ASD were interviewed. The statements were submitted to the process of phenomenological analysis and were unveiled in seven thematic categories: The impact of multiple disabilities; Exclusive dedication to the children; "Twenty-four hours running after it"; "The cochlear implant was a blessing in the life of both of us"; "It is as if he were speaking"; Need for psychosocial support; How they feel now. The mothers revealed how they are subjectively affected in their relationship with the child with CI and diagnosis of ASD, indicating negative impact on the quality of their life. The CI meant the possibility of the child to participate in the audible world and of they, as mother, to have more access to their world. Hope in the development of their child's speech becomes the inspiration to continue the trajectory. The need for supporting services aimed at parents, the importance of interdisciplinary teamwork and the encouragement of the support network are highlighted in the study.

  15. Current steering with partial tripolar stimulation mode in cochlear implants.

    Science.gov (United States)

    Wu, Ching-Chih; Luo, Xin

    2013-04-01

    The large spread of excitation is a major cause of poor spectral resolution for cochlear implant (CI) users. Partial tripolar (pTP) mode has been proposed to reduce current spread by returning an equally distributed fraction (0.5 × σ) of current to two flanking electrodes and the rest to an extra-cochlear ground. This study tested the efficacy of incorporating current steering into pTP mode to add spectral channels. Different proportions of current [α × σ and (1 - α) × σ] were returned to the basal and apical flanking electrodes respectively to shape the electric field. Loudness and pitch perception with α from 0 to 1 in steps of 0.1 was simulated with a computational model of CI stimulation and tested on the apical, middle, and basal electrodes of six CI subjects. The highest σ allowing for full loudness growth within the implant compliance limit was chosen for each main electrode. Pitch ranking was measured between pairs of loudness-balanced steered pTP stimuli with an α interval of 0.1 at the most comfortable level. Results demonstrated that steered pTP stimuli with α around 0.5 required more current to achieve equal loudness than those with α around 0 or 1, maybe due to more focused excitation patterns. Subjects usually perceived decreasing pitches as α increased from 0 to 1, somewhat consistent with the apical shift of the center of gravity of excitation pattern in the model. Pitch discrimination was not better with α around 0.5 than with α around 0 or 1, except for some subjects and electrodes. For three subjects with better pitch discrimination, about half of the pitch ranges of two adjacent main electrodes overlapped with each other in steered pTP mode. These results suggest that current steering with focused pTP mode may improve spectral resolution and pitch perception with CIs.

  16. Assessment and improvement of sound quality in cochlear implant users.

    Science.gov (United States)

    Caldwell, Meredith T; Jiam, Nicole T; Limb, Charles J

    2017-06-01

    Cochlear implants (CIs) have successfully provided speech perception to individuals with sensorineural hearing loss. Recent research has focused on more challenging acoustic stimuli such as music and voice emotion. The purpose of this review is to evaluate and describe sound quality in CI users with the purposes of summarizing novel findings and crucial information about how CI users experience complex sounds. Here we review the existing literature on PubMed and Scopus to present what is known about perceptual sound quality in CI users, discuss existing measures of sound quality, explore how sound quality may be effectively studied, and examine potential strategies of improving sound quality in the CI population. Sound quality, defined here as the perceived richness of an auditory stimulus, is an attribute of implant-mediated listening that remains poorly studied. Sound quality is distinct from appraisal, which is generally defined as the subjective likability or pleasantness of a sound. Existing studies suggest that sound quality perception in the CI population is limited by a range of factors, most notably pitch distortion and dynamic range compression. Although there are currently very few objective measures of sound quality, the CI-MUSHRA has been used as a means of evaluating sound quality. There exist a number of promising strategies to improve sound quality perception in the CI population including apical cochlear stimulation, pitch tuning, and noise reduction processing strategies. In the published literature, sound quality perception is severely limited among CI users. Future research should focus on developing systematic, objective, and quantitative sound quality metrics and designing therapies to mitigate poor sound quality perception in CI users. NA.

  17. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    Science.gov (United States)

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work

  18. Activity patterns of cochlear ganglion neurones in the starling.

    Science.gov (United States)

    Manley, G A; Gleich, O; Leppelsack, H J; Oeckinghaus, H

    1985-09-01

    Spontaneous activity and responses to simple tonal stimuli were studied in cochlear ganglion neurones of the starling. Both regular and irregular spontaneous activity were recorded. Non-auditory cells have their origin in the macula lagenae. Mean spontaneous rate for auditory cells (all irregularly spiking) was 45 spikes s-1. In half the units having characteristic frequencies (CFs) less than 1.5 kHz, time-interval histograms (TIHs) of spontaneous activity showed regularly-spaced peaks or 'preferred' intervals. The spacing of the peak intervals was, on average, 15% greater than the CF-period interval of the respective units. In TIH of lower-frequency cells without preferred intervals, the modal interval was also on average about 15% longer than the CF-period interval. Apparently, the resting oscillation frequency of these cells lies below their CF. Tuning curves (TCs) of neurones to short tone bursts show no systematic asymmetry as in mammals. Below CF 1 kHz, the low-frequency flanks of the TCs are, on average, steeper than the high-frequency flanks. Above CF 1 kHz, the reverse is true. The cochlear ganglion and nerve are tonotopically organized. Low-frequency fibres arise apically in the papilla basilaris and are found near non-auditory (lagenar) fibres. Discharge rates to short tones were monotonically related to sound pressure level. Saturation rates often exceeded 300 spikes s-1. 'On-off' responses and primary suppression of spontaneous activity were observed. A direct comparison of spontaneous activity and tuning-curve symmetry revealed that, apart from quantitative differences, fundamental qualitative differences exist between starling and guinea-pig primary afferents.

  19. 46 CFR 154.170 - Outer hull steel plating.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Outer hull steel plating. 154.170 Section 154.170... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Hull Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the...

  20. Outer space and nuclear deterrence: problems and prospects

    International Nuclear Information System (INIS)

    Gasparini Alves, P.

    1993-01-01

    The presentation deals with the role of outer-space applications and prospects for near future developments in nuclear deterrence. Outer space capabilities of United Sates, Russian Federation, Belarus, Kazakhstan, Ukraine, China, and United Kingdom as well as other states are analyzed. Conceptual problems of offensive and defensive doctrines are reviewed together with legal implications