  1. Responses of commercial broiler chicks to 60Co gamma-rays

    International Nuclear Information System (INIS)

    Shebaita, M.K.; Kamar, G.A.R.; El-Barkouky, E.E.M.

    1981-01-01

    A total of 360 chicks of Nichols line at one-day old were used in this study. Within each sex, the chicks were divided into three exposure treatments (non-irradiated, 400 rads and 800 rads). The source of irradiation was 60 Co gamma-rays. The results can be summarized as follows: Of the 360 chicks used in this study, only 10 chicks died during the experimental period. Radiation induced a reduction in body weight in both sexes during the growth period. Gamma-rays reduce the feed intake in both sexes. Moreover, the feed conversion ratio for the irradiated chicks was higher than that the non-irradiated birds. While red blood cells and hemoglobin content were higher in the irradiated chicks, white blood cells count and especially lymphocytes did not affect by 60 Co gamma-rays. Gamma-rays had no effect on carcass, bone, meat and giblets as fractions of body weight in both sexes. Moreover, meat water content decreased and meat fat content increased in irradiated chicks. The total length and the total weight of the GI tract decreased due to 60 Co gamma-rays. The response of the different regions of the GI tract to this rays is different. Moreover, the effect of this radiation on the GI tract is dependent upon the body weight irrespective of the sex. (orig./MG) [de

  2. Responses of commercial broiler chicks to /sup 60/Co gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Shebaita, M.K.; Kamar, G.A.R.; El-Barkouky, E.E.M.

    1981-12-01

    A total of 360 chicks of Nichols line at one-day old were used in this study. Within each sex, the chicks were divided into three exposure treatments (non-irradiated, 400 rads and 800 rads). The source of irradiation was /sup 60/Co gamma rays. The results can be summarized as follows: Of the 360 chicks used in this study, only 10 chicks died during the experimental period. Radiation induced a reduction in body weight in both sexes during the growth period. Gamma rays reduce the feed intake in both sexes. Moreover, the feed conversion ratio for the irradiated chicks was higher than that the non-irradiated birds. While red blood cells and hemoglobin content were higher in the irradiated chicks, white blood cells count and especially lymphocytes were not affected by /sup 60/Co gamma rays. Gamma rays had no effect on carcass, bone, meat and giblets as fractions of body weight in both sexes. Moreover, meat water content decreased and meat fat content increased in irradiated chicks. The total length and the total weight of the GI tract decreased due to /sup 60/Co gamma rays. The response of the different regions of the GI tract to these rays is different. Moreover, the effect of this radiation on the GI tract is dependent upon the body weight irrespective of the sex.

  3. Effect of /sup 60/Co. gamma. -rays on polyphenyl methacrylate obtained by. gamma. -ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Raghunath, S.; Rao, M.H.; Rao, K.N. (Bhabha Atomic Research Centre, Bombay (India). Chemistry Div.)

    1983-01-01

    Polyphenyl methacrylate of different molecular weights Msub(n) 13000, 34500 and crosslinked polymer prepared by /sup 60/Co ..gamma..-irradiation has been irradiated with /sup 60/Co ..gamma..-rays at 300 K. G(scission) of the 13000 molecular weight polymer was 15. The crosslinked polymer undergoes both degradation and crosslinking. G(x) value determined for that polymer is approx. 9. The gaseous product consists largely of CO with some CO/sub 2/ and H/sub 2/. Hydrocarbon gases were not detected. The yield of H/sub 2/ is only to the extent of 2 to 5% of the total gas and it is assumed that majority of scission takes place at the ester linkage. On the basis of the estimation of phenol and benzene, a mechanism for degradation and crosslinking is proposed.

  4. A comparison of ionizing radiation damage in CMOS devices from 60Co gamma rays, electrons and protons

    International Nuclear Information System (INIS)

    He Baoping; Yao Zhibin; Zhang Fengqi

    2009-01-01

    Radiation hardened CC4007RH and non-radiation hardened CC4011 devices were irradiated using 60 Co gamma rays, 1 MeV electrons and 1-9 MeV protons to compare the ionizing radiation damage of the gamma rays with the charged particles. For all devices examined, with experimental uncertainty, the radiation induced threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays are equal to that of 1 MeV electron and 1-7 MeV proton radiation under 0 gate bias condition. Under 5 V gate bias condition, the distinction of threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays and 1 MeV electrons irradiation are not large, and the radiation damage for protons below 9 MeV is always less than that of 60 Co gamma rays. The lower energy the proton has, the less serious the radiation damage becomes. (authors)

  5. Different gamma ray (60 Co) dose effects on Sorghum genotype germination

    International Nuclear Information System (INIS)

    Tabosa, Jose Nildo; Gomes, Roberto Vicente; Reis, Odemar Vicente dos; Colaco, Waldeciro

    2004-01-01

    In agriculture, applying irradiation is a very valuable way of obtaining vegetable products for human and animal consumption. Cobalt-60, one of the main sources of gamma-rays, is considered an important tool in plant breeding programs, which have the objective of promoting genetic variability of cultivars with resistance to adverse environments. In this research, the effects of different 60 Co doses on germination vigor and seed germination velocity of forage sorghum genotypes were evaluated. The study was carried out at the IPA (Empresa Pernambucana de Pesquisa Agropecuaria) in Recife, Pernambuco, Brazil. The work was installed in germination boxes, following laboratory recommendations. Thus, a experiment involving three sorghum genotypes (IPA 467-4-2, IPA 02-03-01, and Sudan 4202), five 60 Co doses (Zero, 150, 300, 350, and 400 Gy), was set up. The sees were irradiated before the beginning of the experiment being exposed to gamma rays from a 60 Co-source (cobalt irradiator) at DEN (Nuclear Engineering Department) of the UFPE (Pernambuco Federal University), Brazil. The work also had the objective of evaluating the sorghum genotypes x 60 Co dose interaction. The main results obtained showed that the sorghum genotype IPA 02-03-01 presented the greatest values of germination and vigor percentages, and seed germination velocity, when compared to the others evaluated, on 350 and 400 Gy of 60 Co doses. (author)

  6. Functionalization and magnetization of carbon nanotubes using Co-60 gamma-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.Y.; Fu, M.J.; Tsai, C.Y. [Division of Isotope Application, Institute of Nuclear Energy Research, Atomic Energy Council, P.O. BOX 3-27 Longtan, Taoyuan County 32546, Taiwan (R.O.C.) (China); Lin, F.H. [Institute of Biomedical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan (R.O.C.) (China); Chen, K.Y., E-mail: chenky@iner.gov.tw [Division of Isotope Application, Institute of Nuclear Energy Research, Atomic Energy Council, P.O. BOX 3-27 Longtan, Taoyuan County 32546, Taiwan (R.O.C.) (China)

    2014-10-01

    Functionalized magnetic carbon nanotubes (CNTs) can be used in the biological and biomedical fields as biosensors, drug delivery systems, etc., which makes research into processes for manufacturing modified CNTs quite important. In this paper, Co-60 gamma irradiation is shown to be an effective tool for fabricating functionalized and magnetized CNTs. After the Co-60 gamma irradiation, the presence of carboxylic functional groups on the CNT walls was confirmed by their Fourier transform infrared spectra, and the presence of Fe{sub 3}O{sub 4} was verified by the X-ray diffraction patterns. The functionalized and magnetized CNTs produced using Co-60 gamma irradiation have excellent dispersion properties. The techniques for functionalizing and magnetizing CNTs are introduced in this paper, and applications of the modified CNTs will be reported after more data are gathered. - Highlights: Dispersion ability of carbon nanotubes (CNTs) was improved by functionalization. CNTs were easily manipulated by precipitation of magnetic nanoparticles. Our product can be used as versatile biosensor substrate for biomarker screening.

  7. Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

    International Nuclear Information System (INIS)

    Peimel-Stuglik, Z.

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

  8. Effect of spirit irradiation with 60Co gamma-rays

    International Nuclear Information System (INIS)

    Gwardys, S.

    1975-01-01

    A few sorts of spirit were irradiated with a dose of 1 or 5 Mrad of 60 Co gamma-rays. Then the chemical composition of spirits was investigated. It was found that as a result of irradiation the content of acids, esters, acetal aldehydes and methanol increases, while the strength of higher alcohols decreases slightly. The changes of compounds content in particular spirits are dependent on radiation doses and chemical composition before irradiation. It was also discovered that spirit irradiation causes decrease or even disappearance of characteristic - for given spirits - maxima of UV absorption. (Z.M.)

  9. Radiation quality of tritium: a comparison with 60Co gamma rays.

    Science.gov (United States)

    Chen, Jing

    2013-09-01

    In a previous study, microdosimetric simulations were performed for tritium uniformly distributed in a medium, and for tritium bound to biologically critical sites of dimensions from 10 nm to 2 µm. Results of local energy density, i.e. energy deposition in microscopic regions, are different for these two cases. Based on the spatial distribution of energy deposition, dose mean lineal energies are calculated for tritium in the forms of tritiated water (HTO) and organically bound tritium (OBT). The dose mean lineal energies of OBT are about a factor of 1.7 higher than those of HTO in a wide range of target dimensions of biological interest. The results are consistent with radiobiological findings that OBT is about twice as effective as HTO. In this study, the same calculations were performed for (60)Co gamma rays in a wide range of target dimensions of biological interest (10 nm to 2 µm). Compared with (60)Co gamma rays, the estimated relative biological effectiveness could vary from 1.3 to 3.5 for HTO, and 2.3 to 5.6 for OBT. The results are consistent with radiobiological findings for various biological endpoints in different biological systems that OBT is about twice as effective as HTO.

  10. A study on the effect of 60Co gamma ray irradiation on the abrasion of dental polymethylmethacrylate, (3)

    International Nuclear Information System (INIS)

    Kimura, Hiroshi

    1981-01-01

    This report intends to clarify the relationship between the total exposure dose and scratch resistance to the specimens SF, SH, MF and MH, giving coating treatments to P.M.M.A. (dental polymethylmethacrylate) and exposing to the irradiation of 60 Co gamma ray at each dose rate. And based on the results, it is intended to develop coated P.M.M.A. with excellent scratch resistance give by irradiation of radioactive ray. From this study, the following results have been obtained. Irradiation of 60 Co gamma ray would give the best results at the exposure at 1 x 10 6 R. The SF and SH specimens in wet condition exposed to 60 Co gamma ray irradiation at 1 x 10 6 R showed a quantity of abrasion of only 17% that of untreated P.M.M.A. and the barrel test revealed outstanding abrasion and scratch resistance. Abrasion and scratch resistance of coated specimens are better utilized in wet conditions performing three times better than those in dry conditions. (author)

  11. Electrical characteristics of {sup 60}Co {gamma}-ray irradiated MIS Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)]. E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)

    2006-11-15

    In order to interpret the effect of {sup 60}Co {gamma}-ray irradiation dose on the electrical characteristics of MIS Schottky diodes, they were stressed with a zero bias at 1 MHz in dark and room temperature during {gamma}-ray irradiation and the total dose range was 0-450 kGy. The effect of {gamma}-ray exposure on the electrical characteristics of MIS Schottky diodes has been investigated using C-V and G/{omega}-V measurements at room temperature. Experimental results show that {gamma}-ray irradiation induces a decrease in the barrier height {phi} {sub B} and series resistance R {sub s}, decreasing with increasing dose rate. Also, the acceptor concentration N {sub A} increases with increasing radiation dose. The C-V characteristics prove that there is a reaction for extra recombination centers in case of MIS Schottky diodes exposed to {gamma}-ray radiation. Furthermore, the density of interface states N {sub ss} by Hill-Coleman method increases with increasing radiation dose. Experimental results indicate that the interface-trap formation at high irradiation dose is reduced due to positive charge build-up in the Si/SiO{sub 2} interface (due to the trapping of holes) that reduces the flow rate of subsequent holes and protons from the bulk of the insulator to the Si/SiO{sub 2} interface.

  12. Radiosensitivity of California Wonder pepper variety to Co-60 gamma rays

    International Nuclear Information System (INIS)

    Puertas Arias, Ana Leonor; Gonzalez Nunez, Luis Manuel; Ramirez Fernandez, Ramiro

    1998-01-01

    Seeds of California wonder pepper variety were irradiated with dosages among 100-800 Gy, to intervals of 100 Gy, in a source of Co 60 gamma rays, with the objective of determining its radiosensitivity and to establish the adequate interval of dosage for the mutation breeding. A decrease of the growing indicators, productivity and plant fertility was observed with the increasing of irradiation dosages and the interval among 130-460 Gy was established as the most adequate

  13. Multistep process of neoplastic transformation of normal human fibroblasts by 60Co gamma rays and Harvey sarcoma viruses

    Energy Technology Data Exchange (ETDEWEB)

    Namba, M.; Nishitani, K.; Fukushima, F.; Kimoto, T.; Nose, K.

    1986-03-15

    As reported previously (Namba et al., 1985), normal human fibroblasts were transformed by 60Co gamma-ray irradiation into immortal cells with abnormal karyotypes. These transformed cells (KMST-6), however, showed a low cloning efficiency in soft agar and no transplantability. However, upon treatment with Harvey murine sarcoma virus (Ha-MSV), the cells acquired elevated clonability in soft agar and transplantability in nude mice. Ha-MSV alone, however, did not convert normal human fibroblasts into either immortal or tumorigenic cells. The Ha-MSV-transformed KMST-6 cells showed an enhanced expression of the ras oncogene, but normal and 60Co gamma-ray-transformed cells did not. Our current data suggest that gamma rays worked against normal human cells as an initiator, giving rise to chromosome aberrations and immortality, and that Ha-MSV, probably through its ras oncogene, played a role in the progression of the malignant cell population to a more malignant one showing enhanced colony formation in soft agar and tumorigenicity in nude mice.

  14. The effects of Co60 gamma rays on the absorption of salicylic natrium orally given to white rats

    International Nuclear Information System (INIS)

    Wiharto, Kunto; Kamal, Zainul; Mulyanto; Muryono, H.

    1982-01-01

    The effects of Co 60 gamma rays on the absorption of salicylic natrium orally taken by white rats after being irradiated were studied. Patients treated with radiation used to be given analgesic drugs to elicit pain. Effects of radiation on the physiology of gastrointestinal tracts of such patients are to be studied. Based on this perception some white rats were irradiated with Co 60 gamma rays at the cumulative doses of 500, 750, and 1000 rads which were fractionated to 5 daily doses of 100, 150, and 200 rads. Salicylate concentration in the rat's blood was measured with spectrophotometer. It was found that the greater the radiation dose was given, the less salicylic natrium was absorbed and at a certain dose saturation point happened. (RUW)

  15. Micronuclei induced by fast neutrons versus 60Co gamma-rays in human peripheral blood lymphocytes.

    Science.gov (United States)

    Vral, A; Verhaegen, F; Thierens, H; De Ridder, L

    1994-03-01

    Here we compared the effectiveness of neutrons ( = 5.5 MeV) versus 60Co gamma-rays in producing micronuclei (MN) in human lymphocytes. To obtain dose-response data, blood samples of six donors were irradiated with doses ranging from 0.1 to 5 Gy for gamma-rays and 0.1-3 Gy for neutrons. A linear dependence of MN yield with dose was found for fast neutrons while for gamma-rays a nonlinear dependence existed. For both radiation qualities no significant interindividual differences were found. Derived relative biological effectiveness values decreased with increasing dose. The MN frequency distributions were overdispersed with respect to the Poisson distribution, with neutrons showing higher dispersion values than with gamma-rays. To compare the repair kinetics of both radiation qualities split-dose experiments were performed. A dose of 4 Gy gamma-rays (3 Gy neutrons) was delivered either as a single exposure or in two equal fractions separated by time intervals ranging from 30 min to 10 h (30 min to 7 h for neutrons). The data showed for gamma-rays a significant decline (30% +/- 10%) in MN yield with interfraction time due to repair of DNA damage. This repair is a continuous process starting almost immediately after the first of the two doses and lasting 3-5 h. For fast neutrons no decline was observed indicating irreparable damage.

  16. The role of {sup 60}Co gamma-ray irradiation on the interface states and series resistance in MIS structures

    Energy Technology Data Exchange (ETDEWEB)

    Tascioglu, Ilke [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey); Tataroglu, Adem, E-mail: ademt@gazi.edu.t [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey); Ozbay, Akif; Altindal, Semsettin [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey)

    2010-04-15

    The effect of gamma-ray exposure on the metal-insulator-semiconductor (MIS) structures has been investigated using the electrical characteristics at room temperature. The MIS structures are irradiated with {sup 60}Co gamma-ray source. The energy distribution of interface states was determined from the forward bias I-V characteristics by taking into account the bias dependence of the effective barrier height and ideality factor. The value of series resistance decreases with increasing dose. Experimental results confirmed that gamma-ray irradiation have a significant effect on electrical characteristics of MIS structures.

  17. Teratogenic effects of 60Co gamma rays irradiation on rat embryos

    International Nuclear Information System (INIS)

    Lee, Juing-Yi; Okuda, Hiroe; Tutimoto, Sigeo; Satow, Yukio

    1987-01-01

    The teratogenicity of 60 Co gamma rays was evaluated in Donryu rats. The results were compared with those of triterated water (HTO) for determining relative biological effectiveness (RBE) for incidence of malformations and LD 50 in rats. Pregnant rats were irradiated with a 60 Co source at a dose-rate of 0.5 Gy/min or 0.01 Gy/min on day 7, 8, 9, 10 or 11 of gestation with 0.8, 1.0, 1.2, 1.5, 2.0, 2.3, 2.5, 2.8 or 3.0 Gy. HTO was administered intraperitoneal injection to pregnant rats at various doses on day 7, 8, 9, 10 and 11 of gestation. The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Mortality, teratogenicity and effects on fetal growth were day-and dosage-dependent in both radiation groups. Congenital malformations were found most frequently in the 9-day irradiated group and followed by the 8, 11, 10 and 7-day irradiated groups. The incidence of cardiovascular anomalies was highest, especially in the day 9 of gestation group, followed by malformations in the central nervous system, craniofacial system, respiratory system, hind limbs and tail. Beta rays from HTO were found to be more effective than γ rays in inducing congenital malformations. The RBE for incidence of malformations and LD 50 was between 1.3 and 1.5. These studies suggest that simulator of tritium irradiation is urgently needed to investigate the biological effects on rats to estimate the human risks, with respect to RBE of tritium beta rays. (author)

  18. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  19. Study on shelf life extension of papayas irradiated by /sup 60/Co gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Chang, M.S.; Chen, M.D.; Lin, C.T.; Fu, Y.K.

    1984-11-01

    Papayas are one of the main fresh fruits in Taiwan area. Papaya fruits were treated with hot water to pasteurize peels followed by /sup 60/Co gamma-ray irradiation to extend the ripening time. The purpose of synergetic methods is to extend the shelf life of papaya fruits. This experiment was carried out by seven treatments, which were: (1) control group, (2) hot water treatment only, (3) hot water treatment with a 25 krad ..gamma..-irradiation, (4) hot water treatment with a 50 krad ..gamma..-irradiation, (5) hot water treatment with a 75 krad ..gamma..-irradiation, (6) 75 krad ..gamma..-irradiation only, and (7) hot water treatment with a 100 krad ..gamma..-irradiation. The items of observation were: surface yellowing, surface decaying, quality of texture, and length of period lasted after irradiation for 50% marketable papayas. The results of this study showed that a shelf-life extension of six days could be obtained for papayas subjected to hot water (50 to 55/sup 0/C) treatment and a 100 krad irradiation. 3 refs., 2 figs., 2 tabs.

  20. Measurement of Cerenkov Radiation Induced by the Gamma-Rays of Co-60 Therapy Units Using Wavelength Shifting Fiber

    Directory of Open Access Journals (Sweden)

    Kyoung Won Jang

    2014-04-01

    Full Text Available In this study, a wavelength shifting fiber that shifts ultra-violet and blue light to green light was employed as a sensor probe of a fiber-optic Cerenkov radiation sensor. In order to characterize Cerenkov radiation generated in the developed wavelength shifting fiber and a plastic optical fiber, spectra and intensities of Cerenkov radiation were measured with a spectrometer. The spectral peaks of light outputs from the wavelength shifting fiber and the plastic optical fiber were measured at wavelengths of 500 and 510 nm, respectively, and the intensity of transmitted light output of the wavelength shifting fiber was 22.2 times higher than that of the plastic optical fiber. Also, electron fluxes and total energy depositions of gamma-ray beams generated from a Co-60 therapy unit were calculated according to water depths using the Monte Carlo N-particle transport code. The relationship between the fluxes of electrons over the Cerenkov threshold energy and the energy depositions of gamma-ray beams from the Co-60 unit is a near-identity function. Finally, percentage depth doses for the gamma-ray beams were obtained using the fiber-optic Cerenkov radiation sensor, and the results were compared with those obtained by an ionization chamber. The average dose difference between the results of the fiber-optic Cerenkov radiation sensor and those of the ionization chamber was about 2.09%.

  1. Perna perna (LINNAEUS, 1758) mussels irradiated by 60CO gamma rays cytotoxicity evaluation

    International Nuclear Information System (INIS)

    Martini, Gisela A.; Pusceddu, Fabio H.; Rogero, Sizue O.; Rogero, Jose Roberto

    2013-01-01

    The aim of the present work was the study of ionizing radiation effects on aquatic biota regarding the location of nuclear facilities nearby coastal areas assuming the risk of leaks and nuclear accidents. Bivalve mollusks have been widely used in the monitoring of aquatic environment studies mainly for their sessile habit and pollutants bioconcentration ability. So marine mussel Perna perna (Bivalvia: Mytilidae) was used as organism test in this study. The study of radioactive toxicity was performed by cytotoxicity test exposing the organisms to 11Gy gamma radiation dose. After radiation the neutral red retention assay evaluated the lysosomal membrane integrity in the mussel hemocytes. 50% lethal dose assay (LD50) of gamma radiation on Perna perna mussels was carried out by exposure the organisms to 60 Co gamma rays at doses ranging from 0 to 3000 Gy. The result of gamma radiation LD50 for these mussels was 1068 Gy and the neutral red retention time of irradiated organisms was about 47% lower than the control, non irradiated organisms. With the obtained results is expected to contribute in the study to identify the range of ionizing radiation doses which can cause toxic effects in marine invertebrates. (author)

  2. Effect of 60Co gamma-ray irradiation on dilute aqueous solutions of surfactants

    International Nuclear Information System (INIS)

    Sawai, Teruko; Shimokawa, Toshinari; Miki, Yasushi; Oseko, Koichi; Sawai, Takeshi

    1978-01-01

    Present work deals with the effects of gamma irradiation from 60 Co γ-ray source upon aqueous solutions of three kinds of surfactants. When dilute aqueous solutions of sodium dodecyl sulfate (SDS, anionic), cethyl trimethyl ammonium chloride (CTAC, cationic), and polyoxyethylene lauryl ether (POE, non-ionic) were irradiated with γ-rays at a room temperature, the residual concentration, products, surface tension, and forming power were examined by colorimetric method, IR spectrophotometric method, gaschromatography, Ross-Miles method, and Traube's stalagmometer etc. These surfactants were decomposed by the irradiation and thus the surface tension increased and the forming power, on the contrary, decreased with dose. Radiation chemical yields (G-value) of the degradation were about 1 for the solutions of SDS and CTAC, and about 0.3 for the POE solution. From the experimental results, it was found that following chemical reactions seem to occur followed by the radiolysis of water: a) bond cleavage of ester for SDS, of CN for CTAC, and of oxyethylene for POE, b) hydrogen abstraction from the surfactants, c) production of CO bond in the presence of dissolved oxygen. (auth.)

  3. Effect of Zi Gui decoction on immune function in {sup 60}Co {gamma}-ray irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Qiujun, Lu; Shafei, Huang; Xipeng, Zhou; Jiayun, Song; Zhongxiong, Tang [Dept. of Pharmacology, Institute of Radiation Medicine, Beijing (China)

    1995-02-01

    Zi Gui decoction (ZG), a complex preparation of traditional Chinese herbal medicine, mainly consists of Radix Angelicae and Radix Astragali. The effects of ZG on mitogen induced proliferation IL-1 and -2 production, natural killer (NK) cell activity in {sup 60}Co {gamma}-ray irradiated mice is investigated. After 5 Gy whole body irradiation. mice were treated i.g. with ZG (1.2, 1.8 g/kg/day) for 20 days. An enhancement in Con A- and LPS-induced proliferations of splenocytes from the two dosage groups were observed. There were marked increases in IL-1 activity in peritoneal macrophage culturesa and IL-2 activity in splenocyte cultures from irradiated mice treated with ZG. The two dosage groups also showed significant potentiation of NK cell activity against YAC-1 target cells. The above results indicated that ZG could promote the recovery of immune functions in {gamma}-ray irradiated mice.

  4. Perna perna (LINNAEUS, 1758) mussels irradiated by {sup 60}CO gamma rays cytotoxicity evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Martini, Gisela A.; Pusceddu, Fabio H.; Rogero, Sizue O.; Rogero, Jose Roberto, E-mail: gisela.martini@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The aim of the present work was the study of ionizing radiation effects on aquatic biota regarding the location of nuclear facilities nearby coastal areas assuming the risk of leaks and nuclear accidents. Bivalve mollusks have been widely used in the monitoring of aquatic environment studies mainly for their sessile habit and pollutants bioconcentration ability. So marine mussel Perna perna (Bivalvia: Mytilidae) was used as organism test in this study. The study of radioactive toxicity was performed by cytotoxicity test exposing the organisms to 11Gy gamma radiation dose. After radiation the neutral red retention assay evaluated the lysosomal membrane integrity in the mussel hemocytes. 50% lethal dose assay (LD50) of gamma radiation on Perna perna mussels was carried out by exposure the organisms to {sup 60}Co gamma rays at doses ranging from 0 to 3000 Gy. The result of gamma radiation LD50 for these mussels was 1068 Gy and the neutral red retention time of irradiated organisms was about 47% lower than the control, non irradiated organisms. With the obtained results is expected to contribute in the study to identify the range of ionizing radiation doses which can cause toxic effects in marine invertebrates. (author)

  5. The relative biological effectiveness (RBE) of high-energy electrons, x-rays and Co-60 gamma-rays

    International Nuclear Information System (INIS)

    Kiyono, Kunihiro

    1974-01-01

    Linac (Mitsubishi-Shimizu 15 MeV medical linear accelerator) electron beams with actual generated energies of 8, 10, 12 and 15 MeV were compared with X-ray beams having energies of 8 and 10 MV. The RBE values were calculated from 50 percent hatch-ability (LD 50 ) in silk-worm embryos, 30-days lethality (LDsub(50/30)) in ddY mice, and mean lethal dose (Do) in cultured mouse YL cells or human FL cells. To estimate the RBE in clinical experiments, LRD (leukocyte reduction dose) value was calculated for each patient irradiated on the chest or lumbar vertebrae. It was concluded that there is little difference in practical significance between 8 to 10 MV X-rays and 8 to 15 MeV electrons, and that the biological effects of Linac radiations are about 90 to 100 percent of the effect of 60 Co gamma rays. The RBE values gradually decreased, contrary to the elevation of energy between 8 and 15 MeV for electrons and between 8 and 10 MV for X-rays. These values were compared with those of earlier reviews of work in this field, and were briefly discussed. (Evans, J.)

  6. Comparative effects of 60Co gamma-rays and neon and helium ions on cycle duration and division probability of EMT 6 cells. A time-lapse cinematography study.

    Science.gov (United States)

    Collyn-d'Hooghe, M; Hemon, D; Gilet, R; Curtis, S B; Valleron, A J; Malaise, E P

    1981-03-01

    Exponentially growing cultures of EMT 6 cells were irradiated in vitro with neon ions, helium ions or 60Co gamma-rays. Time-lapse cinematography allowed the determination, for individual cells, of cycle duration, success of the mitotic division and the age of the cell at the moment of irradiation. Irradiation induced a significant mitotic delay increasing proportionally with the delivered dose. Using mitotic delay as an endpoint, the r.b.e. for neon ions with respect to 60Co gamma-rays was 3.3 +/- 0.2 while for helium ions it was 1.2 +/- 0.1. Mitotic delay was greatest in those cells that had progressed furthest in their cycle at the time of irradiation. No significant mitotic delay was observed in the post-irradiation generation. Division probability was significantly reduced by irradiation both in the irradiated and in the post-irradiated generation. The reduction in division probability obtained with 3 Gy of neon ions was similar to that obtained after irradiation with 6 Gy of helium ions or 60Co gamma-rays.

  7. Adhesion of thymus lymphocytes to aortic endothelial cells in rats irradiated with sup 60 Co-. gamma. -rays

    Energy Technology Data Exchange (ETDEWEB)

    Yongjian, Geng; Zijun, Mao; Zhiwei, Yin [Suzhou Medical Coll., JS (China)

    1990-03-01

    Adhesion of thymus lymphocytes to aortic endothelial cells in Wistar rats irradiated with {sup 60}Co-{gamma}-rays was preliminarily investigated with a stereological method. The results of experiments suggest that the number of lymphocytes of thymus which adhered to aortic endothelial cells significantly (p < 0.01) decreased after irradiation at doses of 2 and 8 Gy. However, when both thymus and aorta were irradiated, there were more lymphocytes adhering to endothelial cells than that when only thymus was irradiated.

  8. Studies on cannabis. III. Young plants from the seed irradiated with /sup 60/Co gamma rays for inhibiting their development after seeding

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, H; Kuriyama, E; Tomizawa, A [Tokyo Coll. of Pharmacy (Japan)

    1976-01-01

    The seedlings from Cannabis sativa L. seeds irradiated with different doses of ..gamma..-rays were examined, in order to determine the dose sufficient to kill the young plants naturally, before their hallucinnogenic component increases. The seeds of ''Minamioshihara No. 1'', which were harvested in 1972 in Tochigi Prefecture, were irradiated with eight different doses of /sup 60/Co ..gamma..-rays in January 17, 1973, and the seedlings were examined several times during the subsequent 9 months, from March to November 1973, and their morphological and histological effects were examined, and the results are summarized as follows: Samples irradiated with 1500 and 1000 krads developed radicles about 3 mm in length. Samples irradiated with 500, 200, and 50 krads grew into young plants with the first set of leaves, without lateral roots. Samples irradiated with 30 krads grew to about 10 cm high with a few lateral roots, and the epicotyls about 1 cm in length. These young plants from the irradiated seeds stayed in the same condition and then died. Samples irradiated with 15 and 5 krads grew in the same way as the controls until the stage of flowering. Samples irradiated with 500, 200, 50, and 30 krads showerd the cell membranes of endodermis and pericycle to be partially lignified and suberized. The degree of change was related to the dose of ..gamma..-rays. Samples irradiated with 30 krads showed withered cells near the end of the lateral nerves on the first and second set of leaves. The economical dose of /sup 60/Co ..gamma..-rays for inhibiting young plants from developing into adult ones was a minimum of 30 krads which made the young plants die. Irradiation with 50 krads of ..gamma..-rays will be required to kill the young plants completely before they develop the hallucinogenic component.

  9. Mechanical Property Of Zeolite-PVA Composite Mixture Irradiated By Gamma Ray Of Co-60

    International Nuclear Information System (INIS)

    Darsono; Danu, Sugiarto; Las, Tamzil

    2000-01-01

    Experiment on preparation of zeolite-polyvinyl alcohol composite for absorbance materials have been done by curring using Gamma γ-ray of Co-60. Zeolite with the particles size of 60 mesh was mixed with polyvinyl alcohol (PVA) at the concentration of the mixture were 6,9, and 12% by weight, than they were poured into glass tube (length = 100 mm; diameter = 10 mm) and irradiated at the doses of 10, 20, 30 dan 40 kGy with the dose rate of 7,5 kGy/ hr. Parameters observed were density, compressive strength, and hardness. Experimental results showed that polyvinyl alcohol in the mixture was significant effect to density and compressive strength, where as the irradiation dose was highly significant effect to compressive strength. The effect interaction between dose and polyvinyl alcohol concentration factors had significant effect to density or compressive strength. Almost all samples have pencil hardness of 4 - 5 H, for composite containing 6 % PVA, has pencil hardness of 2 - 3 H

  10. Effects of 60Co gamma-rays on some biological characteristics of Chinese hamster lung cells

    International Nuclear Information System (INIS)

    Tang Pei; Wang Shoufang; Zhang Shuxian

    1988-01-01

    The proliferation of cells and the relationship between survival and dose were investigated in Chinese hamster lung (CHL) cells grown at stationary phase and irradiated with 60 Co gamma-rays. The ultrastructural changes and chromosome aberration in the cells after irradiation were also observed. The frequency of chromosome aberrations increased linearly with dose and the yields of dicentrics plus rings were best fitted to a linear-quadratic model. The 50% growth-inhibited dose was found to be 4.0Gy. Electron microscopy observation revealed swelling and vacuolation of mitochodria and indistinct cristae at lower doses. The alterations in nucleus at higher doses appeared to be depression of nuclear membrane and disappearance of chromatin

  11. Fricke dosimetry: the difference between G(Fe3+) for 60Co gamma-rays and high-energy x-rays.

    Science.gov (United States)

    Klassen, N V; Shortt, K R; Seuntjens, J; Ross, C K

    1999-07-01

    A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, which has been calibrated for one particular low-LET beam quality, is used to measure the absorbed dose for another low-LET beam quality, the accuracy of the absorbed dose measurement is limited by the uncertainty in the value of G(Fe3+). The ratio of G(Fe3+) for high-energy x-rays (20 and 30 MV) to G(Fe3+) for 60Co gamma-rays, G(Fe3+)MV(Co), was measured to be 1.007(+/-0.003) (confidence level of 68%) using two different types of water calorimeter, a stirred-water calorimeter (20 MV) and a sealed-water calorimeter (20, 30 MV). This value is consistent with our calculations based on the LET dependence of G(primary products) and, as well, with published measurements and theoretical treatments of G(Fe3+).

  12. Evaluation through comet assay of DNA damage induced in human lymphocytes by alpha particles. Comparison with protons and Co-60 gamma rays

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Kreiner, A. J.; Schuff, J. A.; Vallerga, M. B.; Taja, M. R.; Lopez, F. O.; Alvarez, D. E.; Saint Martin, G.; Burton, A.; Debray, M. E.; Kesque, J. M.; Somacal, H.; Stoliar, P.; Valda, A.; Davidson, J.; Davidson, M.; Ozafran, M. J.; Vazquez, M. E.

    2004-01-01

    Several techniques with different sensitivity to single-strand breaks and/or double strand breaks were applied to detect DNA breaks generated by high LET particles. Tests that assess DNA damage in single cells might be the appropriate tool to estimate damage induced by particles, facilitating the assessment of heterogeneity of damage in a cell population. The microgel electrophoresis (comet) assay is a sensitive method for measuring DNA damage in single cells. The objective of this work was to evaluate the proficiency of comet assay to assess the effect of high LET radiation on peripheral blood lymphocytes, compared to protons and Co-60 gamma rays. Materials and methods: Irradiations of blood samples were performed at TANDAR laboratory (Argentina). Thin samples of human peripheral blood were irradiated with different doses (0-2.5 Gy) of 20.2 MeV helium-4 particles in the track segment mode, at nearly constant LET. Data obtained were compared with the effect induced by a MeV protons and Co-60 gamma rays. Alkaline comet assay was applied. Comets were quantified by the Olive tail moment. Distribution of the helium-4 particle and protons were evaluated considering Poisson distribution in lymphocyte nuclei. The mean dose per nucleus per particle result 0.053 Gy for protons and 0.178 Gy for helium-4 particles. When cells are exposed to a dose of 0.1 Gy, the hit probability model predicts that 43% of the nuclei should have experienced and alpha traversal while with protons, 85% of the nuclei should be hit. The experimental results show a biphasic response for helium-4 particles (0.1 Gy), indicating the existence of two subpopulations: unhit and hit. Distributions of tail moment as a function of fluence and experimental dose for comets induced by helium-4 particles, protons and Co-60 gamma rays were analyzed. With helium-4 irradiations, lymphocyte nuclei show an Olive tail moment distribution flattened to higher tail moments a dose increase. However, for irradiations with

  13. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 gamma-ray beams. Either the Klein-Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source-surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  14. Elimination of N-nitrosamines and their precusors in some foods by /sup 60/Co. gamma. -ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Jifan, Hu; Yingqiang, He; Puju, Song

    1987-10-01

    N-Dimethylnitrosamine (NDMA) in some marine foods, such as dried shrimp, fish meal and salted fish, was drastically reduced by ..gamma..-ray irradiation with /sup 60/Co. The shrimp contained 54.6 ppb NDMA, but only 29.3, 8.8, 11.4, and 1.9 ppb were detected after irradiation with doses of 5, 10, 15 and 20 kGy. The corresponding reduction was 46.3%, 83.9%, 79.1%, and 96.6%, respectively. Similar results were also obtained in other two kinds of foods. NDMA could be completely eliminated by the irradiation in aqueous solution, which was much more markable than that in food samples. The major irradiated products of NDMA were dimethylamine and nitrous acid, but no re-formation of nitrosamines took place. /sup 60/Co irradiation also significantly decreased the content of nitrite in salted fish and in aqueous solution. No effect on nitrate could be observed.

  15. Biochemical and pharmacological characterization of irradiated crotamine by gamma rays of 60Co

    International Nuclear Information System (INIS)

    Oliveira, Karina Corleto

    2014-01-01

    The serum production in Brazil, the only effective treatment in cases of snakebites, uses horses that although large size, have reduced l lifespan compared with horses not immunized. Ionizing radiation has been shown as an excellent tool in reducing the toxicity of venoms and toxins isolated, and promote the achievement of better immunogens for serum production, and contributing to the welfare of serum-producing animals. It is known, however, that the effects of ionizing radiation on protein are characterized by various chemical modifications, such as fragmentation, cross-linking due to aggregation and oxidation products generated by water radiolysis. However, the action of gamma radiation on toxins is not yet fully understood structurally and pharmacologically, a fact that prevents the application of this methodology in the serum production process. So we proposed in this paper the characterization of crotamine, an important protein from the venom of Crotalus durissus terrificus species, irradiated with 60 Co gamma rays. After isolating the toxin by chromatographic techniques and testing to prove the obtaining of pure crotamine, it was irradiated with gamma rays and subjected to structural analysis, Fluorescence and Circular Dichroism. Using high hydrostatic pressure tests were also conducted in order to verify that the conformational changes caused by radiation suffer modifications under high pressures. From the pharmacological point of view, muscle contraction tests were conducted with the objective of limiting the action of crotamine in smooth muscle as well as the change in the action of toxin caused structural changes to the front. Analysis of Circular Dichroism and Fluorescence showed changes in structural conformation of crotamine when subjected to gamma radiation and that such changes possibly occurring in the secondary and tertiary structure of the protein. The observed in pharmacological tests showed that the irradiated crotamine was less effective in

  16. Attenuation of 60Co gamma rays by barium acrylic resin composite shields

    International Nuclear Information System (INIS)

    Abdulla, Riaz; Fidha, Mariyam; Sripathi Rao, B.H.; Kudkuli, Jagadish; Rekha, P.D.; Sharma, S.D.

    2015-01-01

    Oral squamous cell carcinoma is the sixth most common cancer reported globally, with an annual incidence of over 300,000 cases, of which 62% arise in developing countries. Radiation therapy is a treatment modality that uses ionizing radiation as a therapeutic agent. It is widely employed in the treatment of head and neck cancer, as a primary therapy coupled with surgical procedure and chemotherapy or as a palliative treatment for advanced tumors. However, radiotherapy can cause a series of complications such as xerostomia, mucositis, osteoradionecrosis, and radiation caries. Composite circular disc containing different ratios of acrylic and barium sulfate (BaSO 4 ) were made in-house. The purpose of this study was to evaluate the percentage attenuation from these composite shields in 60 Co gamma rays. A maximum of 8% radiation attenuation was achieved using 1:4 ratio of acrylic-BaSO 4 composite shields. The study proposes BaSO 4 as one of the compounds in combination with acrylic resin or any other thermoplastic substances for making biocompatible radiation attenuating devices. (author)

  17. INCASoy-36: soybean variety obtained in Cuba after the induction of mutations with 60Co gamma rays

    International Nuclear Information System (INIS)

    Ortiz, R; FeII, C de la; Ponce M

    2008-01-01

    INCASoy-36 variety was obtained after irradiating seeds from INCASoy-15 at doses of 240 Gy 60 Co gamma rays. This variety is adapted to summer and winter seedings; however, it can also be used in spring. Besides, its yields can reach up to 3,5-4,0 t.ha-1 grains in summer and spring seedings. It is tolerant to the main pests and diseases; it is especially resistant to Meloidogyne incognita attacks. During the adverse spring season, seeds have been damage tolerant. It can assure high productions with low inputs; therefore, it is feasible to Cuban agriculture. (Author)

  18. Accumulation and dissipation of positive charges induced on a PMMA build-up cap of an ionisation chamber by 60Co gamma-ray irradiation

    International Nuclear Information System (INIS)

    Morishita, Y.; Takata, N.

    2013-01-01

    The signal current from an ionisation chamber with a PMMA build-up cap decreases with irradiation time due to electric fields produced by positive charges induced on the cap. In the present study, it was confirmed that the signal current decreases faster for irradiation using narrower 60 Co gamma-ray beams. This is because the number of secondary electrons that are emitted from surrounding materials and penetrate the build-up cap is smaller in a narrower gamma-ray beam, so that fewer positive charges are neutralised. The ionisation chamber was first subjected to continuous gamma-ray irradiation for 24 h, following which it was irradiated with shorter periodic gamma-ray bursts while measuring the current signal. This allowed the coefficients of positive charge accumulation and dissipation to be determined. It was found that the dissipation coefficient has a large constant value during gamma-ray irradiation and decreases asymptotically to a small value after irradiation is stopped. From the coefficients, the minimum signal current was calculated, which is the value when accumulation and dissipation balance each other under continuous irradiation. The time required for the signal current to recover following irradiation was also calculated. (authors)

  19. Analysis of interface states and series resistance at MIS structure irradiated under {sup 60}Co {gamma}-rays

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)], E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)

    2007-10-11

    In this research, we investigated the effect of {sup 60}Co {gamma}-ray exposure on the electrical properties of Au/SnO{sub 2}/n-Si (MIS) structures using current-voltage (I-V) measurements. The fabricated devices were exposed to {gamma}-ray doses ranging from 0 to 300 kGy at a dose rate of 2.12 kGy h{sup -1} in water at room temperature. The density of interface states N{sub ss} as a function of E{sub c}-E{sub ss} is deduced from the forward bias I-V data for each dose by taking into account the bias dependence effective barrier height and series resistance of device at room temperature. Experimental results show that the {gamma}-irradiation gives rise to an increase in the zero bias barrier height {phi}{sub BO}, as the ideality factor n and N{sub ss} decrease with increasing radiation dose. In addition, the values of series resistance were determined using Cheung's method. The R{sub s} increases with increasing radiation dose. The results show that the main effect of the radiation is the generation of interface states with energy level within the forbidden band gap at the insulator/semiconductor interface.

  20. Investigations of immunoglobulins, circulating immune complexes and plasma free hemoglobin in cancer patients on 60Co gamma-ray therapy

    International Nuclear Information System (INIS)

    Horvath, M.; Rode, I.L.; Fekete, B.; Kiss, B.; Ringwald, G.

    1981-01-01

    32 patients with different tumours were irradiated by 60 Co gamma-rays. During therapy lasting for several weeks, changes in the content of immunoglobulin and of some other serum proteins, circulating immune complexes and plasma free hemoglobin were determined. Immunosuppression according to immunoglobulin content in serum was not produced by this type of radiation. Decrease in immune complex levels was a good prognostic sign. Low values of plasma hemoglobin content during treatment indicated that no erythrocyte membrane damage had been effected. (orig.) [de

  1. [Effect of 60Co gamma-irradiation on dilute aqueous solutions of surfactants].

    Science.gov (United States)

    Sawai, T; Shimokowa, T; Miki, Y; Oseko, K; Sawai, T

    1978-01-01

    Present work deals with the effects of gamma irradiation from 60Co gamma-ray source upon aqueous solutions of three kinds of surfactants. When dilute aqueous solutions of sodium dodecyl sulfate (SDS, anionic), cethyl trimethyl ammonium chloride (CTAC, cationic), and polyoxyethylene lauryl ether (POE, non-ionic) were irradiated with gamma-rays at a room remperature, the residual concentration, products, surface tension, and forming power were examined by colorimetric method, IR spectrophotometric method, gaschromatography, Ross-Miles method, and Traube's stalagnometer etc.. These surfactants were decomposed by the irradiation and thus the surface tension increased and the forming power, on the contrary, decreased with dose. Radiation chemical yields (G-value) of the degradation were about 1 for the solutions of SDS and CTAC, and about 0.3 for the POE solution. From the experimental results, it was found that following chemical reactions seem to occur followed by the radiolysis of water; a) bond cleavage of ester for SDS, of CN for CTAC, and of oxyethylene for POE, b) hydrogen abstraction from the surfactants, c) production of CO bond in the presence of dissolved oxygen.

  2. Effects of 2. 0 Gy of /sup 60/Co gamma rays irradiation on rat embryos

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body /sup 60/Co ..gamma.. ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by /sup 60/Co ..gamma.. ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.).

  3. Evaluation of myotoxic activity of Bothropstoxin-1 irradiated with 60Co gamma rays

    International Nuclear Information System (INIS)

    Mirco, Jessica; Baptista, Janaina A.; Caproni, Priscila; Yoshito, Daniele; Nascimento, Nanci do

    2009-01-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules and has been proven to be a powerful tool to attenuate snake venoms toxicity without affecting their immunogenic properties. Snake venoms and their isolated toxins showed structural modifications after gamma radiation process, in aqueous solution, mainly by water radiolysis sub products. Free radical scavengers, such as NaNO 3 and t-butanol, present selective effects on specific radical from water radiolysis. The NaNO 3 has affinity by aqueous electron, while the t-butanol has affinity by hydroxyl radical. At the present work, we have investigated the myotoxic activity of Bothropstoxin-1 (BTHX-1), a K49 phospholipase, present in Bothrops jararacussu crude venom, before and after irradiation process, with or without scavenger substances presence. BTHX-1 was irradiated with 2 kGy of 60 Co gamma rays, in aqueous solution and in the presence of oxygen. BALB/c mice were inoculated with either native or irradiated toxin, with or without scavenger substances. After 3 hours, blood samples were collected and the myotoxic activity was evaluated by LDH (lactate dehydrogenase) release. The muscular tissue damage was directly related to the LDH amounts released. Irradiated Bothropstoxin-1, with or without NaNO 3 substance, caused less damage than their native counterpart. But irradiated toxin, in the presence of t-butanol, was so myotoxic as the native BTHX-1. These results indicate that irradiation of toxic proteins can promote significant modifications on their structures, but still retaining many of the original biological properties of their native counterparts. Additionally, some scavengers substances can change these gamma radiation effects. (author)

  4. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  5. Radiation inactivation of Paenibacillus larvae and sterilization of American Foul Brood (AFB) infected hives using Co-60 gamma rays

    International Nuclear Information System (INIS)

    De Guzman, Zenaida M.; Cervancia, Cleofas R.; Dimasuay, Kris Genelyn B.; Tolentino, Mitos M.; Abrera, Gina B.; Cobar, Ma. Lucia C.; Fajardo, Alejandro C.; Sabino, Noel G.; Manila-Fajardo, Analinda C.; Feliciano, Chitho P.

    2011-01-01

    The effectiveness of gamma radiation in inactivating the Philippine isolate of Paenibacillus larvae was investigated. Spores of P. larvae were irradiated at incremental doses (0.1, 0.2, 0.4, 0.8 and 1.6 kGy) of gamma radiation emitted by a 60 Co source. Surviving spores were counted and used to estimate the decimal reduction (D 10 ) value. A dose of 0.2 kGy was sufficient to inactivate 90% of the total recoverable spores from an initial count of 10 5 -9x10 3 spores per glass plate. The sterilizing effect of high doses of gamma radiation on the spores of P. larvae in infected hives was determined. In this study, a minimum dose (D min ) of 15 kGy was tested. Beehives with sub-clinical infections of AFB were irradiated and examined for sterility. All the materials were found to be free of P. larvae indicating its susceptibility to γ-rays. After irradiation, there were no visible changes in the physical appearance of the hives' body, wax and frames. Thus, a dose of 15 kGy is effective enough for sterilization of AFB-infected materials. - Highlights: → We characterized Paenibacillus larvae and determined its radiation sensitivity. → We investigated the effectiveness of gamma rays in inactivating P. larvae. → Gamma radiation inactivates P. larvae. → 15 kGy is effective for the sterilization of P. larvae-infected hives. → Irradiation produces no visible changes in the hives' body, waxes and frames.

  6. Radiation inactivation of Paenibacillus larvae and sterilization of American Foul Brood (AFB) infected hives using Co-60 gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    De Guzman, Zenaida M. [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Cervancia, Cleofas R. [Institute of Biological Sciences, College of Arts and Sciences, University of the Philippines, Los Banos, Laguna (Philippines); Dimasuay, Kris Genelyn B.; Tolentino, Mitos M.; Abrera, Gina B.; Cobar, Ma. Lucia C. [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Fajardo, Alejandro C.; Sabino, Noel G.; Manila-Fajardo, Analinda C. [Institute of Biological Sciences, College of Arts and Sciences, University of the Philippines, Los Banos, Laguna (Philippines); Feliciano, Chitho P., E-mail: cpfeliciano@pnri.dost.gov.ph [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Institute of Biology, College of Science, University of the Philippines, Diliman, Quezon City (Philippines)

    2011-10-15

    The effectiveness of gamma radiation in inactivating the Philippine isolate of Paenibacillus larvae was investigated. Spores of P. larvae were irradiated at incremental doses (0.1, 0.2, 0.4, 0.8 and 1.6 kGy) of gamma radiation emitted by a {sup 60}Co source. Surviving spores were counted and used to estimate the decimal reduction (D{sub 10}) value. A dose of 0.2 kGy was sufficient to inactivate 90% of the total recoverable spores from an initial count of 10{sup 5}-9x10{sup 3} spores per glass plate. The sterilizing effect of high doses of gamma radiation on the spores of P. larvae in infected hives was determined. In this study, a minimum dose (D{sub min}) of 15 kGy was tested. Beehives with sub-clinical infections of AFB were irradiated and examined for sterility. All the materials were found to be free of P. larvae indicating its susceptibility to {gamma}-rays. After irradiation, there were no visible changes in the physical appearance of the hives' body, wax and frames. Thus, a dose of 15 kGy is effective enough for sterilization of AFB-infected materials. - Highlights: > We characterized Paenibacillus larvae and determined its radiation sensitivity. > We investigated the effectiveness of gamma rays in inactivating P. larvae. > Gamma radiation inactivates P. larvae. > 15 kGy is effective for the sterilization of P. larvae-infected hives. > Irradiation produces no visible changes in the hives' body, waxes and frames.

  7. Nutritional balance of pigs irradiated on the hind part with 1100 rd of 60Co gamma rays

    International Nuclear Information System (INIS)

    Daburon, F.; Tricaud, Y.; Bourhoven, D.; Marion, C.

    1978-01-01

    The hind part of 10 adult miniature pigs was irradiated with 1100 rd of 60 Co gamma rays. The dietary mineral (Na, K, Ca, P), nitrogen and lipid balances of the animals were studied before and 1, 3 and 5 months after irradiation. While the classical early lesion of the intestinal mucosa recovered quite satisfactorily within one or two months, a pancreatic atrophy process developed progressively which might play a major role in the nutritional state of the pigs and thus in their survival. Concerning nutritional balance, nitrogen and sodium retention were perturbed until 5 months post-irradiation; cyanocobalamin absorption remained very low. Dry and organic matter utilization recovered nearly normal values in the 3rd ou 5th month [fr

  8. Qualities of Patin Fishball Irradiated by Gamma Rays (60Co)

    International Nuclear Information System (INIS)

    Yarosita FS; Bustami I; Winarti Z; Rindy PT

    2004-01-01

    An experiment on patin fishball quality using gamma irradiation ( 60 Co) has been conducted. Samples were irradiated at 0, 1, 3 and 5 kGy and stored in refrigerator at temperature 10 o C for sixty days. Samples were analysed every fifteen days, except content of fat and protein that analysed only at the beginning and the end of storage. The purpose of this experiment is to know the quality changes of patin fishball irradiated during storage, by measuring of chemical (content of fat, protein, water, TVB value, pH value) and microbiology (TPC aerobic and anaerobic bacteria) changes. The results showed that irradiation did not affect macro nutrient contents (content of fat, protein and water) of patin fishball during storage but irradiation can affect TVB and pH values. Irradiation at 1 kGy can reduce one logarithmic cycle of total aerobic and anaerobic bacteria. The storage life of irradiated patin fishball treated at 1, 3 and 5 kGy could be extended up to 15, 30 and 60 days, respectively. Control samples the storage life could be extended less than 15 days. (author)

  9. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  10. Development of the 60Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water (ND,W)

    International Nuclear Information System (INIS)

    Fukumura, Akifumi; Mizuno, Hideyuki; Fukahori, Mai; Sakata, Suoh

    2013-01-01

    A primary standard for the absorbed dose rate to water in a 60 Co gamma-ray field was established at National Metrology Institute of Japan (NMIJ) in fiscal year 2011. Then, a 60 Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water was developed at National Institute of Radiological Sciences (NIRS) as a secondary standard dosimetry laboratory (SSDL). The results of an International Atomic Energy Agency (IAEA)/World Health Organization (WHO) TLD SSDL audit demonstrated that there was good agreement between NIRS stated absorbed dose to water and IAEA measurements. The IAEA guide based on the International Organization for Standardization (ISO) standard was used to estimate the relative expanded uncertainty of the calibration factor for a therapy-level Farmer type ionization chamber in terms of absorbed dose to water (N D,W ) with the new field. The uncertainty of N D,W was estimated to be 1.1% (k=2), which corresponds to approximately one third of the value determined in the existing air kerma field. The dissemination of traceability of the calibration factor determined in the new field is expected to diminish the uncertainty of dose delivered to patients significantly. (author)

  11. Simulating 60 Co gamma irradiation systems

    International Nuclear Information System (INIS)

    Omi, Nelson M.; Rela, Paulo R.

    2000-01-01

    The use of Cadgamma, a software dedicated to simulate 60 Co gamma irradiation systems, can lead to an optimized process and simulating, in a few hours, many configurations setups for the irradiation elements. The software can also simulate changes in the path of the product and the influence of any steady body like the support of the product support and source shoulders. These simulations minimize the number of dose mapping tests in industrial applications and allow the study of unusual setups. Cadgamma was developed at IPEN to simulate it is multipurpose 60 Co irradiation system, under construction and planned to be operating by the second half of 2001. The software was used on project stage and will help to optimize the irradiation process for each product to be treated. (author)

  12. Evaluation of myotoxic activity of Bothropstoxin-1 irradiated with {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Mirco, Jessica; Baptista, Janaina A.; Caproni, Priscila; Yoshito, Daniele; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: jessica.mirco@yahoo.com.br, e-mail: janabap@gmail.com, e-mail: pricaproni@hotmail.com, e-mail: daniyoshito@uol.com.br, e-mail: nnascime@ipen.br

    2009-07-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules and has been proven to be a powerful tool to attenuate snake venoms toxicity without affecting their immunogenic properties. Snake venoms and their isolated toxins showed structural modifications after gamma radiation process, in aqueous solution, mainly by water radiolysis sub products. Free radical scavengers, such as NaNO{sub 3} and t-butanol, present selective effects on specific radical from water radiolysis. The NaNO{sub 3} has affinity by aqueous electron, while the t-butanol has affinity by hydroxyl radical. At the present work, we have investigated the myotoxic activity of Bothropstoxin-1 (BTHX-1), a K49 phospholipase, present in Bothrops jararacussu crude venom, before and after irradiation process, with or without scavenger substances presence. BTHX-1 was irradiated with 2 kGy of {sup 60}Co gamma rays, in aqueous solution and in the presence of oxygen. BALB/c mice were inoculated with either native or irradiated toxin, with or without scavenger substances. After 3 hours, blood samples were collected and the myotoxic activity was evaluated by LDH (lactate dehydrogenase) release. The muscular tissue damage was directly related to the LDH amounts released. Irradiated Bothropstoxin-1, with or without NaNO{sub 3} substance, caused less damage than their native counterpart. But irradiated toxin, in the presence of t-butanol, was so myotoxic as the native BTHX-1. These results indicate that irradiation of toxic proteins can promote significant modifications on their structures, but still retaining many of the original biological properties of their native counterparts. Additionally, some scavengers substances can change these gamma radiation effects. (author)

  13. Resveratrol effects on life span and fertility of caenorhabditis elegans subject to 60Co gamma ray irradiation

    International Nuclear Information System (INIS)

    Ye Kai; Ji Chenbo; Guo Xirong; Gu Guixiong

    2011-01-01

    Caennorhabditis elegans was used as experimental model to investigate radiation effect of resveratrol on caenorhabditis elegans irradiated by 60 Co γ ray. Treatment with resveratrol can increase average life span and spawning rate, improve the survival rate of eggs, and protect their mitochondrion function of caenorhabditis elegans exposure to 60 Co γ ray. The results indicate that resveratrol has radiation protection effects, which might be related to its action on ROS decrease and mitochondrial defend. (authors)

  14. Comparative nephrotoxicity of native or Co-60 gamma rays irradiated crotoxin in mice

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Andre Moreira; Alves, Glaucie J.; Aires, Raquel da Silva; Turibio, Thompson O.; Thomazi, Gabriela O. Coelho; Spencer, Patrick J.; Nascimento, Nanci do, E-mail: andrerocha@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Nascimento-Rocha, Josefa M.; Magalhaes Filho, Asterio Souza, E-mail: 0304@prof.itpacporto.com.br [Instituto Tocantinense Presidente Antonio Carlos Porto (ITPAC), Porto Nacional, TO (Brazil)

    2015-07-01

    Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is the crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with {sup 60}Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of those animals employed on antivenom production. At the present work, we have compared the effects of native and irradiated crotoxin on the mice renal function. Tubular lesions were observed in all the samples from the animal group injected with native crotoxin. Animals injected with the irradiated toxin presented alteration only after 30 minutes and 1 hour after injection. These data suggest that the onset of the renal lesions is delayed and that the severity of the lesions might be lower when using irradiated crotoxin. (author)

  15. Comparative nephrotoxicity of native or Co-60 gamma rays irradiated crotoxin in mice

    International Nuclear Information System (INIS)

    Rocha, Andre Moreira; Alves, Glaucie J.; Aires, Raquel da Silva; Turibio, Thompson O.; Thomazi, Gabriela O. Coelho; Spencer, Patrick J.; Nascimento, Nanci do; Nascimento-Rocha, Josefa M.; Magalhaes Filho, Asterio Souza

    2015-01-01

    Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is the crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with 60 Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of those animals employed on antivenom production. At the present work, we have compared the effects of native and irradiated crotoxin on the mice renal function. Tubular lesions were observed in all the samples from the animal group injected with native crotoxin. Animals injected with the irradiated toxin presented alteration only after 30 minutes and 1 hour after injection. These data suggest that the onset of the renal lesions is delayed and that the severity of the lesions might be lower when using irradiated crotoxin. (author)

  16. X-ray and gamma radiography devices

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    When we are using this technique, we also must familiar with the device and instrument that used such as gamma projector, crawler, x-ray tubes and others. So this chapter discussed detailed on device used for radiography work. For the x-ray and gamma, their characteristics are same but the source to produce is a big different. X-ray produced from the machine meanwhile, gamma produce from the source such as Co-60 and IR-192. Both are electromagnetic waves. So, the reader can have some knowledge on what is x-ray tube, discrete x-ray and characteristic x-ray, how the machine works and how to control a machine, what is source for gamma emitter, how to handle the projector and lastly difference between x-ray and gamma. Of course this cannot be with the theory only, so detailed must be learned practically.

  17. Decoloration Kinetics of Waste Cooking Oil by 60Co γ-ray/H2O2

    Science.gov (United States)

    Xiang, Yulin; Xiang, Yuxiu; Wang, Lipeng

    2016-03-01

    In order to decolorize, waste cooking oil, a dark red close to black solution from homes and restaurants, was subjected to 60Co γ-ray/H2O2 treatment. By virtue of UV/Vis spectrophotometric method, the influence of Gamma irradiation to decoloration kinetics and rate constants of the waste cooking oil in the presence of H2O2 was researched. In addition, the influence of different factors such as H2O2 concentration and irradiation dose on the decoloration rate of waste cooking oil was investigated. Results indicated that the decoloration kinetics of waste cooking oil conformed to the first-order reaction. The decoloration rate increased with the increase of irradiation dose and H2O2 concentration. Saponification analysis and sensory evaluation showed that the sample by 60Co γ-ray/H2O2 treatment presented better saponification performance and sensory score. Furthermore, according to cost estimate, the cost of the 60Co γ-ray/H2O2 was lower and more feasible than the H2O2 alone for decoloration of waste cooking oil.

  18. Cytogenetic comparison of the responses of mouse and human peripheral blood lymphocytes to 60Co gamma radiation

    International Nuclear Information System (INIS)

    Kligerman, A.D.; Halperin, E.C.; Erexson, G.L.; Honore, G.; Westbrook-Collins, B.; Allen, J.W.

    1988-01-01

    Experiments were conducted to compare the chromosome damaging effects of 60 Co gamma radiation on mouse and human peripheral blood lymphocytes (PBLs). Either whole blood or isolated and pelleted mononuclear leucocytes (MNLs) were irradiated with a 60 Co unit to yield exposures of 1, 2, 3, or 4 Gy. In addition, mice were whole-body irradiated in vivo with the same doses so that an in vitro-in vivo comparison could be made. The results indicate that mouse PBLs irradiated in whole blood, whether in vivo or in vitro, respond similarly to 60 Co gamma rays as measured by dicentric chromosome formation. In addition, mouse and human PBLs showed a similar radiosensitivity, but because the mouse PBL data were best fitted to an exponential function and the human PBL data to a quadratic function, direct comparisons were difficult to make. Pelleted MNLs from mice were much less sensitive to the clastogenic effects of gamma radiation than whole blood. This is believed to be due to hypoxic conditions that developed during irradiation and transport. Human PBLs did not show a marked difference whether irradiated in whole blood or as pelleted MNLs in tissue culture medium

  19. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1980-04-01

    Relative intensities and intensities per decay of gamma rays were evaluated for 16 nuclides, 22 Na, 24 Na, 46 Sc, 54 Mn, 60 Co, 85 Sr, 88 Y, 95 Nb, sup(108m)Ag, 134 Cs, 133 Ba, 139 Ce, sup(180m)Hf, 198 Au, 203 Hg and 207 Bi. For most of these nuclides disintegration rates can be determined by means of β-γ or X-γ coincidence method. Since decay schemes of these nuclides are established, intensities per decay of strong gamma rays were accurately evaluated by using weak beta-ray branching ratios, relative gamma-ray intensities and internal conversion coefficients. Half-lives of the nuclides were also evaluated. Use of the nuclides, therefore, are recommended for precision intensity calibration of the detectors. (author)

  20. Relative Biological Effectiveness of 14-MeV Fast Neutrons to Co{sup 60} Gamma-Rays in Einkorn Wheat; Efficacite Biologique Relative des Neutrons Rapides de 14 MeV par Rapport aux Rayons Gamma de {sup 60}Co sur l'Engrain; Otnositel'naya biologicheskaya ehffektivnost' bystrykh nejtronov s ehnergiej 14 MeV i gamma-luchej CO{sup 60} pri ikh dejstvii na pshenitsu odnozernyanku; EBR de los Neutrones Rapidos de 14 MeV y de los Rayos Gamma del {sup 60}Co en el Trigo Escanda Menor

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Institute of Genetics, Misima (Japan)

    1964-05-15

    The author investigated the RBE of 14 MeV neutrons to Co{sup 60} gamma-rays by using the specific locus method in Einkorn wheat. F{sub 1} seeds from the cross between the original strain and a chlorina mutant were used in this study (chlorina mutant was obtained as a single recessive mutant from X-irradiation; it was uniformly light green from seedling stage to maturity with relatively high survival rate and fertility). The F{sub 1} plants showed normal green colour and normal growth habit. Dormant F{sub 1} seeds were irradiated at 0.5 , 1.0 and 1.4 krad of fast neutrons ami 4.3 , 8.6 and 12.9 krad of gamma-rays. Mutations from dominant normal green to chlorina occurred by both irradiations and appeared in the leaves and stems of the heterozygotic Xi plants as longitudinal stripes. Around 80% of seeds germinated in the control lot and in the lowest dosage lots from both neutron and gamma-ray irradiations, and germination percentages were gradually decreased with increasing dosage of both kinds of radiation. Moreover, a similar tendency was observed at the early stage as to seedling growth which was gradually inhibited with increasing dosage. According to these results, neutron irradiation was about 13 times more effective than that of gamma-rays. Survival rate in the non-irradiated control was about 90% and about 60-80% of germinated seedlings survived in 0.5 and 1.0 krad lots from neutron irradiation and all lots irradiated by gamma-rays. On the other hand, only about 4% of germinated seedlings survived in the highest neutron lot. No mutation was observed in the control lot, and the number of plants which contained striped tillers increased with increasing dosage of both kinds of radiation. Mutated tillers were observed in about 15% of surviving plants obtained at the lowest dosage of neutron irradiation and a similar frequency was observed from the highest dosage of gamma-rays. RBE of 14 MeV neutrons to Co{sup 60} gamma-rays seemed to be at least 20 for the

  1. The effect of {sup 60}Co ({gamma}-ray) irradiation on the electrical characteristics of Au/SnO{sub 2}/n-Si (MIS) structures

    Energy Technology Data Exchange (ETDEWEB)

    Goekcen, M. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey); Tataroglu, A. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey)], E-mail: ademt@gazi.edu.tr; Altindal, S.; Buelbuel, M.M. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey)

    2008-01-15

    The effect of {sup 60}Co ({gamma}-ray) irradiation on the electrical properties of Au/SnO{sub 2}/n-Si (MIS) structures has been investigated using the capacitance-voltage (C-V) and conductance-voltage (G/{omega}-V) measurements in the frequency range 1 kHz to 1 MHz at room temperature. The MIS structures were exposed to {gamma}-rays at a dose rate of 2.12 kGy/h in water and the range of total dose was 0-500 kGy. It was found that the C-V and G/{omega}-V curves were strongly influenced with both frequency and the presence of the dominant radiation-induced defects, and the series resistance was increased with increasing dose. Also, the radiation-induced threshold voltage shift ({delta}V{sub T}) strongly depended on radiation dose and frequency, and the density of interface states N{sub ss} by Hill-Coleman method decreases with increasing radiation dose.

  2. Disturbed tooth formation by 60Co-gamma-ray radiation

    International Nuclear Information System (INIS)

    Doh, Akio

    1982-01-01

    The molar of guinea pigs was irradiated with 60 Co-#betta# ray for daily observations of the manifestation of disturbed tooth formation by microradiography and the time registration by tetracycline-labelling. Irradiation first injured young blast cells of the dentin in the growth phase, dental pulp cells, and cells of the enamel. The portion composed of injured cells formed a depressed ''constriction'' from the dental pulp side toward the border between the enamel and dentin. The cells of the enamel injured by irradiation in the growth phase later formed a very thin irregular stroma. In contrast, cells in the differentiation or subsequent phase at the time of irradiation and cells probably having started to grow after irradiation proceeded with formation of a normal stroma and calcification. No uniform relation was obtained between the histological staining of the organic stroma of normal or abnormal dentin and calcification. Labelling with tetracycline revealed that the irradiation conditions in the present study provoked hardly any changes in the speed of tooth eruption. (Chiba, N.)

  3. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  4. Oxygen enhancement ratio (OER) to Neutron and Co-60 γ ray

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Ji, Young Hoon; Lee, Yong Min; Kim Kyeoung Jung

    1997-01-01

    Experiments in vitro, using human cell lines was carried out in order to establish whether or not there was a difference between oxygen enhancement ratio (OER) of neutron and Co-60 γ-ray and to determine OER dependence on radiation dose. MG-63 cell line and H-460 cell line were defined as the most sensitive cell line to neutron among our laboratory holding cell lines through preliminary study. Anoxia as was produced in glove box. The box was flushed for one hour with a mixture of 5 % CO 2 in ultrapure N 2 (total oxygen concentration < 10 ppm) and irradiated with neutron and Co-60 γ-ray. Oxic condition was same as anoxic condition except being irradiated in general air condition. The lower OER was observed in neutron than in Co-60 γ-ray. The dose dependence of OER was observed in neutron and Co-60 γ-ray all. But the dose dependence of the OER is somewhat larger for Co-60 γ-ray than for neutron. In the range of 1 to 8 Gy, the OER for photon and neutron range from 1.54 to 1.94 and 1.23 to 1.26 in MG-63 cell line. In case of H-460 the OER for Co-60 γ-ray and neutron range from 1.24 to 1.60 and 1.06 to 1.07 respectively. (author). 19 refs., 5 tabs., 5 figs

  5. Dosimetric properties of dysprosium doped calcium magnesium borate glass subjected to Co-60 gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Omar, R. S., E-mail: ratnasuffhiyanni@gmail.com; Wagiran, H., E-mail: husin@utm.my; Saeed, M. A. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2016-01-22

    Thermoluminescence (TL) dosimetric properties of dysprosium doped calcium magnesium borate (CMB:Dy) glass are presented. This study is deemed to understand the application of calcium as the modifier in magnesium borate glass with the presence of dysprosium as the activator to be performed as TL dosimeter (TLD). The study provides fundamental knowledge of a glass system that may lead to perform new TL glass dosimetry application in future research. Calcium magnesium borate glass systems of (70-y) B{sub 2}O{sub 3} − 20 CaO – 10 MgO-(y) Dy{sub 2}O{sub 3} with 0.05  mol % ≤ y ≤ 0.7  mol % of dyprosium were prepared by melt-quenching technique. The amorphous structure and TL properties of the prepared samples were determined using powder X-ray diffraction (XRD) and TL reader; model Harshaw 4500 respectively. The samples were irradiated to Co-60 gamma source at a dose of 50 Gy. Dosimetric properties such as annealing procedure, time temperature profile (TTP) setting, optimization of Dy{sub 2}O{sub 3} concentration of 0.5 mol % were determined for thermoluminescence dosimeter (TLD) reader used.

  6. DNA damage and γH2AX expression in EJ cells induced by 60Co gamma-rays

    International Nuclear Information System (INIS)

    Pan Yan; Tian Mei; Liu Jianxiang; Ruan Jianlei; Su Xu

    2009-01-01

    Objective: To investigate 60 Co γ-rays induced DNA damage of human bladder cancer cell line EJ cells and the relationship between different doses of 60 Co γ-rays, γH2AX foci number and γH2AX expression level. Methods: EJ cells were exposed to different doses of 60 Co γ-rays and the oliver tail moment (TM) of EJ cells were analyzed with single cell gel electrophoresis (SCGE) . Immunofluorescent microscopy was used to analysis γH2AX foci formation in EJ cells after exposure to different doses of γ-ray irradiation and time-course after exposure to 2 Gy γ-ray irradiation. FACSAria was used to detect the changes of γH2AX protein expression in EJ cells. Results: The TMs of EJ cells were increased with the irradiation dose. The TM of 0 Gy group and 4 Gy group was 0.24 and 5.26, respectively. Immunofluorescent analysis demonstrated that γH2AX foci could be induced by γ-ray irradiation in dose-dependent and time-dependent manners. The foci number and size in nuclei of EJ cells was significantly increased after exposed to different doses of γ-ray irradiation and the foci remained detectable at 24 h after exposed to irradiation. The dose range in which foci could be clearly detected was from 0.1 to 4 Gy. FACSDiva showed that γH2AX protein expression was increased after exposure to different doses of γ-ray irradiation. γH2AX protein expression level of 0.1 Gy group and 4 Gy group was 7.4% and 29.2% , respectively. Conclusions: γH2AX foci could be the most sensitive indicator for DNA damage and repair in mammalian cells, and it might be a new biomarker for radiological emergency. (authors)

  7. The effect of gamma radiation from sources "6"0Co of soybean for shade tolerant

    International Nuclear Information System (INIS)

    Lilik Harsanti; Yulidar

    2016-01-01

    Gamma rays are electromagnetic waves that have a very strong penetrating power. One of the sources of gamma rays is from "6"0Co. The gamma rays have strong penetration power can be used of plant breeding to create new genetic diversity in the make of high-yielding varieties. Irradiation of gamma rays at a dose of 300 gray and 400 gray on soybean Denna 1 seed varieties has been done, then it was planted as M.1 the plants look healthy and robust and strong stems. The parameters observed plant height, sum book leaf, sum seed, sum pod and Percentage plant to live shade tolerant. The parameters observed were good: plant height doze 300 Gy (37.76 cm) and 400 gray (33.03 cm) The number of branches with doze 300 Gy (1.75) and 400 Gy (1.95), number of pod with doze 300 Gy (26.25) and 400 Gy (24.72), number of seed with doze 300 Gy (35.55 kg) and 400 Gy (33.65 kg), number of Naut with doze 300 Gy (9.28) and 400 Gy (8.53) and the percentage of plants capable of shade tolerant with doze 300 Gy (85) and 400 Gy(75). In conclusion, selection mutant lines of soybeans shade tolerant at generation M1 and next generation. (author)

  8. Effect of Co-60 single escape peak on detection of Cs-137 in analysis of radionuclide from research reactor

    International Nuclear Information System (INIS)

    Kim, M. S.; Park, S. J.

    2006-01-01

    The effect of the single escape peak of 1173 keV gamma-rays from Co-60 on the detection of Cs-137 activity is analyzed. The single escape peak of 1173 keV gamma-rays from Co-60 is located at the 662 keV, which is very close to the energy of gamma-rays from Cs-137. This single escape peak may be mistaken for the gamma-ray peak from Cs-137 activity in the case of large area of 1173 keV peak. The detection of Cs-137 is very important to the judgment of the contamination or the leakage of the material containing the fission product like reactor pool water and in the several experiments for reactor physics such as burn-up estimation. In this work, the areas of the single escape peak of the 1173 keV gamma-rays from Co-60 are measured with several full energy peak areas by using the HPGe detector. The critical limit by which we can decide whether the net count of 662 keV peak due to Co-60 would be significant or not is deduced. For this detection system, when the area of full energy peak is larger than 4.5 million, the single escape peak of 1173 keV gamma-rays from Co-60 can be regarded as the single significant peak. Therefore, it is confirmed that the detection of the Cs-137 activity is affected by the Co-60 in this case. Conservatively, for this detection system, it is recommended that the area of 1173 keV peak of Co-60 would be less than 2 million for neglecting the effect of Co-60. (authors)

  9. Calculation of direct effects of {sup 60}Co gamma rays on the different DNA structural levels: A simulation study using the Geant4-DNA toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Tajik, Marjan; Rozatian, Amir S.H. [Department of Physics, University of Isfahan, Hezar Jarib Street, Isfahan 81746-73441 (Iran, Islamic Republic of); Semsarha, Farid, E-mail: Semsarha@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box: 13145-1384, Tehran (Iran, Islamic Republic of)

    2015-03-01

    In this study, simple single strand breaks (SSB) and double strand breaks (DSB) due to direct effects of the secondary electron spectrum of {sup 60}Co gamma rays on different organizational levels of a volume model of the B-DNA conformation have been calculated using the Geant4-DNA toolkit. Result of this study for the direct DSB yield shows a good agreement with other theoretical and experimental results obtained by both photons and their secondary electrons; however, in the case of SSB a noticeable difference can be observed. Moreover, regarding the almost constant yields of the direct strand breaks in the different structural levels of the DNA, calculated in this work, and compared with some theoretical studies, it can be deduced that the direct strand breaks yields depend mainly on the primary double helix structure of the DNA and the higher-order structures cannot have a noticeable effect on the direct DNA damage inductions by {sup 60}Co gamma rays. In contrast, a direct dependency between the direct SSB and DSB yields and the volume of the DNA structure has been found. Also, a further study on the histone proteins showed that they can play an important role in the trapping of low energy electrons without any significant effect on the direct DNA strand breaks inductions, at least in the range of energies used in the current study.

  10. Induction of mutation, through gamma rays, in sugarcane

    International Nuclear Information System (INIS)

    Vieira, M.A.S.; Matsuoka, S.; Ruschel, R.

    1984-01-01

    Variety buds Co-740 of sugar cane were irradiated with gamma rays 60 Co at 0.0, 3.0, 4.0, 5.0, 6.0 and 7.0 kR to study changes in the obtained progeny. Evaluation of the germination capacity, height of plants and morphological changes were studied in the different treatments. (M.A.C.) [pt

  11. Comparative effectiveness of gamma-rays and electron beams in food irradiation

    International Nuclear Information System (INIS)

    Hayashi, Toru

    1991-01-01

    Ionizing radiations which can be used for the treatment of foods are gamma-rays from Co-60 and Cs-137, accelerated electrons from a machine at an energy of 10 MeV or lower and X-rays from a machine at an energy of 5 MeV or lower. The Joint FAO/IAEA/WHO Expert Committee on the Wholesomeness of Irradiated Food held in 1980 concluded that the foods irradiated at overall average doses up to 10 kGy with the radiation listed above are wholesome for human consumption. While most of the commercial food irradiations are conducted with gamma-rays from Co-60, accelerated electrons are increasingly utilized for treating foods. An important difference between gamma-rays and accelerated electrons is the penetration capacity in materials. The penetration capacity of gamma-rays is much higher than that of accelerated electrons. Another important difference is the dose rate. The dose rates of gamma-rays from commercial Co-60 sources are 1-100 Gy/min, while those of electron beams from electron accelerators are 10 3 -10 6 Gy/s. Ideally a comparison of the effect of different types of ionizing radiation should be carried out at the same dose rate but this has been difficult due to the design of irradiators. It is very difficult to draw a definite conclusion on the difference in the effectiveness in food irradiation between gamma-rays and electron beams based on published data. This chapter deals with as many reports as possible on the comparative effectiveness of gamma-rays and electron beams and on the effect of dose rate on chemical reactions and living organisms, whether or not they demonstrate any dependency of the effect of irradiation on dose rate and type of radiation. (author)

  12. (60)Co in cast steel matrix: A European interlaboratory comparison for the characterisation of new activity standards for calibration of gamma-ray spectrometers in metallurgy.

    Science.gov (United States)

    Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe

    2016-08-01

    Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Biochemical and pharmacological characterization of irradiated crotamine by gamma rays of {sup 60}Co; Caracterizacao bioquimica e farmacologica da crotamina irradiada por raios gama de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Karina Corleto

    2014-07-01

    The serum production in Brazil, the only effective treatment in cases of snakebites, uses horses that although large size, have reduced l lifespan compared with horses not immunized. Ionizing radiation has been shown as an excellent tool in reducing the toxicity of venoms and toxins isolated, and promote the achievement of better immunogens for serum production, and contributing to the welfare of serum-producing animals. It is known, however, that the effects of ionizing radiation on protein are characterized by various chemical modifications, such as fragmentation, cross-linking due to aggregation and oxidation products generated by water radiolysis. However, the action of gamma radiation on toxins is not yet fully understood structurally and pharmacologically, a fact that prevents the application of this methodology in the serum production process. So we proposed in this paper the characterization of crotamine, an important protein from the venom of Crotalus durissus terrificus species, irradiated with {sup 60}Co gamma rays. After isolating the toxin by chromatographic techniques and testing to prove the obtaining of pure crotamine, it was irradiated with gamma rays and subjected to structural analysis, Fluorescence and Circular Dichroism. Using high hydrostatic pressure tests were also conducted in order to verify that the conformational changes caused by radiation suffer modifications under high pressures. From the pharmacological point of view, muscle contraction tests were conducted with the objective of limiting the action of crotamine in smooth muscle as well as the change in the action of toxin caused structural changes to the front. Analysis of Circular Dichroism and Fluorescence showed changes in structural conformation of crotamine when subjected to gamma radiation and that such changes possibly occurring in the secondary and tertiary structure of the protein. The observed in pharmacological tests showed that the irradiated crotamine was less effective

  14. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  15. Recent status on cobalt-60 gamma ray radiation sources production and its application in China

    International Nuclear Information System (INIS)

    Cao Zhijian; Song Yunjiang; Zhang Chunhua; Li Maoling

    1993-01-01

    This paper describes the status of Co-60 γ ray radiation sources and their application in China. At present, the production capacity of Co-60 γ ray radiation sources in China is about 11.1 PBq (0.3 MCi) per year. 5 years later, it is increased to 37 PBq (1 MCi) per year. The radioactivity of each source is 370 TBq - 740 TBq (1000-2000 Ci). There are over 150 Co-60 γ ray radiation facilities with total design capacity of over 370 PBq (10 MCi) and practical capacity of about 92.5 PBq (2.5 MCi) in operation. The number of Co-60 γ ray radiation facilities with practical capacity of over 3.7 PBq (0.1 MCi) is 14. The main applications of the Co-60 γ ray sources are radiation crosslinking, radiation sterilization of disposable medical supplies and food irradiation. The prospects for Co-60 γ ray radiation source application in China are good. (author)

  16. Gamma ray induced fruit quality variations in banana variety Nendran (Musa Paradasiaca L.)

    International Nuclear Information System (INIS)

    Radha Devi, D.S.; Nayer, N.K.

    1992-01-01

    Gamma ray induced fruit quality variation was envisaged to analyse the direct effect of Co 60 gamma rays in banana variety Nendran. Fruit quality analysis showed that the total soluble solids and acidity decreased and total sugar and sugar acid ratio increased with increase in dose of gamma ray exposures. (author). 5 refs., 1 tab

  17. Effects of 60Co γ-ray irradiation on human platelets

    International Nuclear Information System (INIS)

    Wu Guoxin; Zhao Yiming; Ruan Changgeng

    1991-02-01

    Human platelet-rich plasma was irradiated with various doses (0,1.25,2.5,5.0,10,20,40Gy) of 60 Co γ-ray so as to observing the changes of metabolites and releasing substances of platelets. Alpha-granule membrane protein (GMP-140) molecules on the surface of platelet was expressed significantly increasing when the dosage of 60 Co γ-ray was 5 Gy; however, the glycoprotein (GP) I b and III a was not changed significantly; thromboxane B 2 production in plasma was significantly elevated while the γ-ray was only 2.5 Gy; the concentration of von Willebrand factor was increased when the γ-ray was over 5 Gy, this is in accordance with the GMP-140 molecules. These results indicate that platelets could be activated in vitro when the dosage of 60 Co γ was over 5 Gy

  18. Application of the alanine detector to gamma-ray, X-ray and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Hansen, J.W.; Byrski, E.

    1987-01-01

    A dosimeter based on alanine has been developed at the INP in Krakow and at Risoe National Laboratory. Due to its near tissue-equivalence and stability of signal, measured using ESR spectrometry at room temperature, this free-radical amino-acid dosimetric system is particularly suitable for measuring X-ray, gamma-ray and fast neutron doses in the range 10-10 5 Gy. The relative effectiveness (with respect to 60 Co γ-rays) of the alanine dosimeter to 250 kVp X-rays and to cyclotron-produced fast neutrons (mean neutron energy 5.6 MeV) is measured to be 0.76± 0.06 and 0.60±0.05, respectively. The suitability of the alanine dosimeter for intercomparison gamma-ray dosimetry is also shown. The estimated absolute difference between 60 Co dosimetry at Risoe National Laboratory and at the Centre of Oncology in Krakow is about 5%, somewhat more than the experimental uncertainty. These results are based on ESR measurements performed in Krakow on about 25% of the exposed detectors. 28 refs., 2 figs., 3 tabs. (author)

  19. Meiosis and ISSR analysis on genetic variation of {sup 60}Co {gamma}-rays irradiated variants of cut chrysanthemum

    Energy Technology Data Exchange (ETDEWEB)

    Lili, Xing; Fadi, Chen; Hengbin, Miao [College of Horticulture, Nanjing Agricultural University, Nanjing, Jiangsu (China)

    2009-08-15

    Cytology and ISSR technology were used to analyze genetic variations of {sup 60}Co {gamma}-rays induced variants of cut chrysanthemum 'Changzi', for further exploring the mechanism of irradiation and providing theoretical basis for breeding of chrysanthemum. The results showed that, meiotic abnormality ratio of lagging chromosome and chromosome bridge in variants were significantly higher than those in the control at anaphase I and II. The abnormality ratio was also raised with irradiation doses increasing. The highest ratio of two abnormal phenomena at anaphase I was 9.0%, 11.3%, and at anaphase II 15.5%, 8.6%, respectively. Polymorphic bands of 112 were amplified by 21 ISSR primers and the polymorphism rate was 71.3%, which proved that DNA changed in different degrees. These variants were divided into 5 groups by UPGMA based on Jaccard coefficient. It was observed that the clustering result related to their characters of flower shape and color variations. (authors)

  20. Study of irradiated bothropstoxin-1 with 60Co gamma rays: immune system behavior

    International Nuclear Information System (INIS)

    Caproni, P.; Baptista, J.A.; Almeida, T.L. de; Nascimento, N.; Passos, L.A.C.

    2009-01-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules. Very promising results were obtained when crude animal venoms, as well as isolated toxins, were treated with 60Co gamma rays, yielding toxoids with good immunogenicity. The achievement of modified antigens with lower toxicity and preserved or improved immunogenicity can be very useful. Ionizing radiation has already been proven to be a powerful tool to attenuate snake venom toxicity without affecting, and even increasing, their immunogenic properties. However, little is known about the modifications that irradiated molecules undergo and even less about the immunological response that such antigens elicit. In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase, before and after irradiation. Structural modifications of the toxin were analyzed by SDS-PAGE. Isogenic mice were immunized with either the native or the irradiated toxin. The circulating antibodies were isotyped and titrated by ELISA. According to our data, irradiation promoted structural modifications in the toxin characterized by higher molecular weight forms of proteins (aggregates and oligomers). The results also indicated that irradiated toxins were immunogenic and antibodies elicited by them were able to recognize the native toxin in ELISA. These findings suggest that irradiation of toxic proteins can promote significant modifications in their structures; however they still retain many of the original antigenic and immunological properties of native proteins. Also, our data indicate that irradiated proteins induce higher titers of IgG2a and IgG2b, suggesting that Th1 cells are predominantly involved in the immune response. (author)

  1. Mutant in tobacco anther culture induced by 60Co γ-rays

    International Nuclear Information System (INIS)

    Tong Daoru; Jia Xinghua

    1991-01-01

    The tobacco anthers at uninucleate eccentric stage were irradiated by 60 Co γ-rays for the purpose of inducing desirable mutants. The results showed that the induction frequency of plantlets increased following 1kR of 60 Co γ-rays treatment. However, the time of plantlet induction was delayed and the percentage of responding anthers as well as the number of plantlets induced per anther significantly decreased after 3kR of 60 Co γ-ray radiation which was considered as a semilethal exposure. The plantlet numbers induced per anther were extremely low following 6kR of 60 Co γ-ray radiation. A white flower mutant appeared in the induced progenies. The tobacco leaf quality of this mutant were significantly improved as compared with its parental line. The mutant line has been tested and proved to have commercial value though the resistance to the black shank of tobacco slightly decreased as compared with the parental line

  2. Evaluation of gamma-ray intensities

    International Nuclear Information System (INIS)

    Yoshizawa, Yasukazu; Inoue, Hikaru; Hoshi, Masaharu; Shizuma, Kiyoshi; Iwata, Yosei.

    1978-03-01

    Results of literature survey and evaluation of relative intensities and intensities per decay of gamma rays are presented. Evaluations were made for 22 Na, 24 Na, 46 Sc, 48 Sc, 48 V, 54 Mn, 57 Co, 60 Co, 85 Sr, 88 Y, 95 Nb, 95 Zr, sup(108m)Ag, 134 Cs, 137 Cs, 144 Ce, 144 Pr, 203 Hg, and 207 Bi. For eight of the nuclides, the half-lives were also evaluated. (auth.)

  3. Co-60 gamma radiation assisted diffusion of iodine in polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, N.L.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ernet.i [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India)

    2010-09-15

    Thin films of polypropylene having dimensions 50 mm x 15 mm x 350 {mu}m were immersed in 1 N iodine solution and then irradiated with Co-60 gamma radiation for the periods of 48, 96 and 144 h at the doses varying from 14.4 to 43.2 kGy. The films were also kept immersed in iodine solution for similar periods but without irradiation. Furthermore, the films were also directly-irradiated with Co-60 gamma radiation for similar periods and doses. The radiation-iodinated, plain-iodinated and directly-irradiated samples were characterized by using various techniques such as weight gain EDS, SEM, FTIR, UV-visible spectroscopy, contact angle and XRD. Weight gain, EDS and SEM collectively reveal that gamma irradiation enhances iodine intake in polypropylene. FTIR, EDS and contact angle measurements indicate that presence of iodine during irradiation resists radiation induced carbonylation of polypropylene. FTIR also shows presence of HOI (Hypoiodous acid) species instead of expected C-I bonds. UV-visible analysis unambiguously shows that presence of iodine enhances radiation induced band gap reduction process of polypropylene. XRD indicates that iodine decreases the crystallinity of polypropylene.

  4. Immune response against antigens irradiated with 60Co gamma-rays

    International Nuclear Information System (INIS)

    Baptista, J.A.; Spencer, P.J.; Oliveira, J.E.; Casare, M.S.; Nascimento, N.

    2006-01-01

    In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase from Bothrops jararacussu, and of ovalbumin before and after irradiation with 60 Co γ-rays. Isogenic mice were immunized with either native or irradiated proteins. The circulating antibodies were isotyped and titrated by ELISA. Results indicate that irradiated proteins were immunogenic and the antibodies elicited by them were able to recognize the native proteins in ELISA. Data also indicate that the irradiated protein induced higher titers of IgG2a and IgG2b, suggesting that Th1 cells were predominantly involved in the immune response. Structural modifications of the proteins were investigated by SDSPAGE, mass spectrometry and size exclusion chromatography. According to our data, irradiation promoted structural modifications on both proteins, characterized by higher molecular weight forms (aggregates and oligomers). When analyzed by mass spectrometry, the irradiated bothropstoxin appeared in several oxidized forms. These results indicate that irradiation of toxic proteins can promote significant modifications in their structures, but still retain many of the original antigenic and immunological properties of native form. (author)

  5. The induction mutation effects of "6"0Co gamma radiation on physiological growth of tomato

    International Nuclear Information System (INIS)

    Gusti Ngurah Sutapa; I Gde Antha Kasmawan

    2016-01-01

    Almost all types of cuisine in Indonesia are using tomatoes as the base material of manufacture. The nutritional value contained in tomatoes is also quite high, because there is a number of vitamin content required by the human body. In addition, the tomatoes in plants featured national horticultural commodity and priority on a number of provinces in Indonesia. So many benefits of tomatoes indicates that the productivity of tomatoes should be improved. One improvement in terms of quality can be done by means of mutation induction with gamma radiation of Co-60. Induction of mutations are genetic changes caused by human effort, one of them is by using radioactive materials. Gamma rays of Co-60 from the IRPASENA facility was exposed to tomato seeds at doses of 50, 100, 150, 200 and 250 Gy. And then measurements were conducted on the physiological growth of leaf width, plant height, number of fruit and wet weight of tomatoes from week 1 until harvest. The results showed a growth curve of tomato is in accordance with sigmoidal plant physiological growth curve. Optimal physiological growth of tomato plants was obtained at dose of gamma radiation of 100 Gy. At this optimal dose physiological growth of tomato plants is the best (superior) than in doses below and above 100 Gy and control. (author)

  6. Effects on artificial blood substitute (Fluosol-DA) by 60Co gamma-ray irradiation

    International Nuclear Information System (INIS)

    Hishikawa-Itoh, Youko; Ayakawa, Yoshio; Miyata, Nobuki

    1982-01-01

    It had been demonstrated the high oxygen solubility of perfluorochemical emulsion (Fluosol-DA), and Fluosol-DA is going to apply as an oxygen carrier, namely artificial blood substitutes for clinical application. There have been many reports on physical, chemical and biological aspects of Fluosol-DA, but not have been reported on irradiation effects. In this paper, we investigated the effects on Fluosol-DA by 60 Co γ-ray irradiation. 1. pH of Fluosol-DA was increased apparently, this effect was not by irradiation, but by thermal effect. 2. Optical density of Fluosol-DA at 620 nm which meaned an effect on particles of Fluosol-DA was not changed by γ-irradiation. 3. F - ion concentration of Fluosol-DA which meaned an effect on structure of perfluorochemical was not changed merkedly. 4. The solubility of oxygen of Fluosol-DA was slightly increased by γ-irradiation at 25 0 C and 11 0 C, but this effect was disregarded. These results suggested that 60 Co γ-irradiation did not effect on pH, size or aggregation of particles, release of F - ion from Fluosol-DA and solubility of oxygen of Fluosol-DA. (author)

  7. [Raman spectra study on radiation damage in EC9706 cells by 60Cogamma-rays].

    Science.gov (United States)

    Qi, Jian; Guo, Zheng-Yuan; Zhang, Guang-Shui; Wu, Dian-Yong; Tang, Wei-Yue

    2009-07-01

    Raman spectrum was used to study the structure and content of protein, nucleic acid and fat, while EC9706 cells irradiated by 60Co gamma-ray were cultivated for 24 h. The results showed that for spectrum intensity and frequency deviation, there were big differences between each exposure group and control group. For the 1 244 cm(-1) peak of amide III, beta folder changed to disordered conformations in the middle dose (4, 5Gy) groups. The 1 341 cm(-1) peak of v (the indole ring of Trp) was red-shifted in every dose group. There was a 2-3 cm(-1) red shift at the 782 cm(-1) peak in the big dose groups (7, 8Gy). It was showed that the non-hydrogenation of v(s)(PO2-) was strengthened due to big dose gamma-rays radiation. There was a 4 cm(-1) blue shift at the 1 446 cm(-1) peak of delta (CH2, CH3). It maybe resulted from 60Co gamma-rays' damage to the film of EC9706 cells. The preferable dose of 60Co gamma-rays may be found by analyzing the variety of the above-mentioned peaks in some dose groups.

  8. Differential production of proteolytic enzymes by normal human fibroblasts and their counterparts transformed by treatment with 60Co gamma rays

    International Nuclear Information System (INIS)

    Nishitani, Koji; Namba, Masayoshi; Ohkubo, Shigeki; Kimoto, Tetsuo

    1985-01-01

    Production of proteolytic enzymes by human fibroblasts in the process of transformation was investigated. The cells used were normal human fibroblasts (KSM-6) and their in vitro counterparts transformed by treatment with 60 Co gamma rays (KMST-6). Cells seeded by treatment with EDTA were cultured in a serum free medium. Proteolytic enzymes in the culture medium of cells were assayed using a synthetic substrate, N-α-(p-tosyl)-L-arginine ( 3 H) methyl ester hydrochloride. The transformed cells (KMST-6) produced a larger amount of enzymes than normal cells (KMS-6). The enzyme production in both cell lines was high in the exponential growth stage and then decreased as the cells reached confluency. The proteolytic enzymes produced by these cells were trypsin- and thrombin-like enzymes. Cell growth of KMST-6 or KMS-6 was not inhibited by the addition of protease inhibitors to the culture medium. (author)

  9. Study of irradiated bothropstoxin-1 with {sup 60}Co gamma rays: immune system behavior

    Energy Technology Data Exchange (ETDEWEB)

    Caproni, P.; Baptista, J.A.; Almeida, T.L. de; Nascimento, N. [Nuclear and Energy Research Institute (IPEN/CNEN-SP), SP (Brazil). Biotechnology Center; Passos, L.A.C. [State University of Campinas (UNICAMP), SP (Brazil). Lab. of Genetics and Embryo Cryopreservation

    2009-07-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules. Very promising results were obtained when crude animal venoms, as well as isolated toxins, were treated with 60Co gamma rays, yielding toxoids with good immunogenicity. The achievement of modified antigens with lower toxicity and preserved or improved immunogenicity can be very useful. Ionizing radiation has already been proven to be a powerful tool to attenuate snake venom toxicity without affecting, and even increasing, their immunogenic properties. However, little is known about the modifications that irradiated molecules undergo and even less about the immunological response that such antigens elicit. In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase, before and after irradiation. Structural modifications of the toxin were analyzed by SDS-PAGE. Isogenic mice were immunized with either the native or the irradiated toxin. The circulating antibodies were isotyped and titrated by ELISA. According to our data, irradiation promoted structural modifications in the toxin characterized by higher molecular weight forms of proteins (aggregates and oligomers). The results also indicated that irradiated toxins were immunogenic and antibodies elicited by them were able to recognize the native toxin in ELISA. These findings suggest that irradiation of toxic proteins can promote significant modifications in their structures; however they still retain many of the original antigenic and immunological properties of native proteins. Also, our data indicate that irradiated proteins induce higher titers of IgG2a and IgG2b, suggesting that Th1 cells are predominantly involved in the immune response. (author)

  10. Effect of 60Co gamma irradiation on cochlea function and structure in guinea pigs

    International Nuclear Information System (INIS)

    Wang Zhonghe; Cai Yilin; Hu Haisen

    1994-01-01

    In the experiment inner ears of guinea pigs were irradiated with 60 Co gamma rays using the method of simulated clinical routine irradiation in order to find the effects of ionizing radiation on the cochlea function and structure and to explore the mechanism and protective measure that lead to hearing impairment following radiotherapy to the head and neck of cancer patients. Ten weeks after irradiation it was found that ABR threshold increased with increasing dose of radiation. The mean values of ABR thresholds in 70 Gy and 90 Gy groups were 10 dB and 28 dB respectively. The number of inner and outer hair cell and pillar cell loss was counted under microscope. The number of lost cells increased with increasing dose of radiation. The severity of damage in morphology of inner, outer hair cells and pillar cells reduced progressively. The groups of 70 Gy and 90 Gy lost significantly more than groups of control and 50 Gy(P<0.05). It is concluded that the damage of hair cells of cochlea is the direct result of gamma ray irradiation of the inner ear and is the main cause of hearing impairment following irradiation

  11. Determination of the displacement cross-section in C-60 fullerene exposed to the gamma rays

    International Nuclear Information System (INIS)

    Leyva, A.; Pinnera, I.; Leyva, D.; Cruz, C.; Abreu, Y.

    2011-01-01

    Using the threshold energy values reported in literature for spherical fullerene C-60 molecules and taking into account the McKinley-Feshbach approach, the effective atomic displacement cross-section in C-60 nanostructures exposed to the gamma rays was estimated. The Kinchin-Pease approximation for the damage function was also considered. These calculations were performed using MCCM code system developed by the authors for the study of gamma radiation damage in solid materials. (Author)

  12. The effect of gamma ray on growth and anatomy structure of garlic leaf (A. sativum L.)

    International Nuclear Information System (INIS)

    Sumiyarsih, S.; Aliudin

    1990-01-01

    This experiment was conducted in Experimental Garden Banaran, East Java. This experiment used Complete Randomized Design with 10 replications and 7 treatments as followed: garlic seeds were radiated by gamma Co 60, with dosage 0, 2, 4, 6, 8, 10, and 12 krad. The result of this experiment showed that radiated treatment of gamma Co 60 ray decreased growth percentage, plants became dwarf, root growth was short, and dosage 10 and 12 krad resulted in rotten root. Also radiation of gamma Co 60 decreased number of stomata and diameter of trachea became smaller

  13. Effect of {gamma}-ray irradiation on the magnetic properties of NdFeB and Fe-Cr-Co permanent magnets

    Energy Technology Data Exchange (ETDEWEB)

    Gao, R.S. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Zhen, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)]. E-mail: zhenl@hit.edu.cn; Li, G.A. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Xu, C.Y. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Shao, W.Z. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2006-07-15

    The effect of {gamma}-ray irradiation on the magnetic properties of NdFeB and Fe-Cr-Co permanent magnets has been investigated. The magnetic flux loss of two kinds of magnets before and after irradiation was measured. Results show that the effect of {gamma}-ray irradiation on the magnetic properties of sintered NdFeB is not so obvious as that on Fe-Cr-Co magnet. Irradiation-induced damage from {gamma}-ray for the Fe-Cr-Co magnets was characterized for the first time. The decline of permanent magnetic properties of Fe-Cr-Co magnet induced by {gamma}-ray irradiation is reversible except for the maximum energy product (BH){sub max}. The difference of coercivity mechanism between these two kinds of permanent magnets is responsible for the different dependence of magnetic properties loss induced by {gamma}-ray irradiation.

  14. [Chinese medicinal monomer and compound for 60Co-gamma-induced spermatogenic disturbance in mice].

    Science.gov (United States)

    Zhang, Wei-xing; Wang, Hua-li; Wang, Rui; Li, Rui; He, Wei; Zhang, Tian-biao

    2010-05-01

    To explore the effects of the monomer and compound of the Chinese herbal drugs resveratrol, lycium barbarum polysaccharide (LBP) and icariin on 60Co-gamma-induced spermatogenic disturbance in mice based on the theory of modern Chinese medicine. A total of 105 male Kunming mice were randomly divided into seven groups, with 15 in each. Group A were normally raised and Groups B, C, D, E, F and G irradiated by 60Co-gamma 6 Gy followed by 60Co-gamma 4 Gy at the interval of 7 days. A week later, Groups C, D, E, F and G received intragastrically the suspension of resveratrol, resveratrol + LBP, resveratrol + icariin, resveratrol + LBP + icariin and resveratrol + LBP + icariin + L-carnitine, respectively, at the dose of 80 mg/(kg x d) for 60 days. The general condition, physical signs and body weight changes of the mice were recorded, and 24 hours after the intragastric medication, their testes were harvested to obtain the testicular weight and indexes, the levels of FSH, LH, T and E2 determined by ELISA, the T/E2 ratio calculated, and the histology of the testis tissues observed under the microscope. The testicular indexes of the mice were decreased by radiation-induced damage, but restored to some extent after intragastric medication, especially in Groups E, F and G. The levels of FSH, LH and T were obviously improved by LBP. The T level and testis weight were increased by Icariin. The level of T/E2 was elevated in Groups E, F and G. The best results were achieved in Group F, which exhibited almost complete recovery from reproductive endocrine disorder and spermatogenic damage. The Chinese medicinal monomer is effective for 60Co-gamma-induced spermatogenic disturbance in mice, and the compound suspension of resveratrol + LBP + icariin produces the best result.

  15. A novel comprehensive utilization of vanadium slag: As gamma ray shielding material

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Mengge [School of Metallurgy, Northeastern University, Shenyang 110004 (China); Liaoning Key Laboratory of Metallurgical Resources Recycling Science, Shenyang 110004 (China); Xue, Xiangxin, E-mail: xuexx@mail.neu.edu.cn [School of Metallurgy, Northeastern University, Shenyang 110004 (China); Liaoning Key Laboratory of Metallurgical Resources Recycling Science, Shenyang 110004 (China); Yang, He; Liu, Dong [School of Metallurgy, Northeastern University, Shenyang 110004 (China); Liaoning Key Laboratory of Metallurgical Resources Recycling Science, Shenyang 110004 (China); Wang, Chao [Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Li, Zhefu [Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2016-11-15

    Highlights: • A novel comprehensive utilization method for vanadium slag is proposed. • Shielding properties of vanadium slag are better than ordinary concrete. • HVL of vanadium slag is between Lead and concrete to shield {sup 60}Co gamma ray. • HVL of composite is higher than concrete when adding amount of vanadium slag is 900. • Composite can be used as injecting mortar for cracks developed in concrete shields. - Abstract: New exploration of vanadium slag as gamma ray shielding material was proposed, the shielding properties of vanadium slag was higher than concrete when the energy of photons was in 0.0001 MeV–100000 MeV. Vanadium slag/epoxy resin composites were prepared, shielding and material properties of materials were tested by {sup 60}Co gamma ray, simultaneous DSC-TGA, electronic universal testing machine and scanning electron microscopy, respectively. The results showed that the shielding properties of composite would be better with the increase of vanadium slag addition amount. The HVL (half value layer thickness) of vanadium slag was between Lead and concrete while composite was higher than concrete when the addition amount of vanadium slag was 900 used as material to shield {sup 60}Co gamma ray, also the resistance temperature of composite was about 215 °C and the bending strength was over 10 MPa. The composites could be used as injecting mortar for cracks developed in biological concrete shields, coating for the floor of the nuclear facilities, and shielding materials by itself.

  16. Study on effects of gamma-ray irradiation on TlBr semiconductor detectors

    International Nuclear Information System (INIS)

    Matsumura, Motohiro; Watanabe, Kenichi; Yamazaki, Atsushi; Uritani, Akira; Kimura, Norihisa; Nagano, Nobumichi; Hitomi, Keitaro

    2016-01-01

    Radiation hardness of thallium bromide (TlBr) semiconductor detectors to 60 Co gamma-ray irradiation was evaluated. The energy spectra and μτ products of electrons were measured to evaluate the irradiation effects. No significant degradation of spectroscopic performance of the TlBr detector for 137 Cs gamma-rays was observed up to 45 kGy irradiation. Although the μτ products of electrons in the TlBr detector slightly decreased, position of the photo-peak was stable without significant degradation after the gamma-ray irradiation. We confirmed that the TlBr semiconductor detector has a high tolerance for gamma-ray irradiation at least up to 45 kGy. (author)

  17. Detection of gamma rays using scintillation optical fibers

    International Nuclear Information System (INIS)

    Park, J. W.; Hong, S. B.

    2002-01-01

    Scintillating optical fibers have several advantages over other conventional materials used for radiation detection. We have used glass and plastic scintillating fibers to detect gamma rays emitted from 60 Co and 137 Cs, and beta rays from 90 Sr. The sensors are constructed of single strand or multi-strand fibers of 1 mm diameter. The glass scintillating fiber used contains cerium-activated lithium-silicate as scintillating material and the plastic scintillating fiber used is Bicron model BCF-12. In this paper, we report the pulse-height spectra obtained by both sensor types, and analyze them in the aspect of their usability for radiation detectors. Our investigation suggests that the glass fiber can be used to develop gamma ray detectors which will function in high and low gamma ray flux environments. Use of the sensor for the beta ray detection was not satisfactory. The plastic fiber sensor did not work satisfactorily for the weak gamma sources, but did produce somewhat promising results. The scintillating plastic fiber offers some feasibility as beta ray sensor material

  18. Analysis of the microbial growth in 60Co gamma-irradiated foods by calorimetry

    International Nuclear Information System (INIS)

    Furuta, M.; Hamasaki, K.; Wirkner, S.; Constantinoiu, E.; Takahashi, K.; Hayashi, T.

    2002-01-01

    Using a heat conduction calorimeter equipped with 24 sample units the heat evolutions from growing 60Co gamma-irradiated bioburden of black pepper seeds and frozen beef were detected in the form of growth thermograms. 60Co gamma-irradiation affected the growth pattern in which a dose-dependent reduction of the growth rate constant was observed together with the retardation in growth, indicating a combination of bactericidal and bacteriostatic effects. We successfully determined the minimal inactivation doses for the two food samples using the relationship between the irradiation dose and the retardation in growth talpha, or the growth rate constant mu obtained from the growth thermograms. These results strongly suggested the possibility of calorimetry as a measure of predictive microbiology in food irradiation

  19. The effect of build-up cap materials on the response of an ionization chamber to 60Co gamma rays

    International Nuclear Information System (INIS)

    Rocha, M.P.O.; Almeida, C.E. de

    1993-01-01

    Knowledge of the effect of wall and build-up cap materials on ionization chamber response is necessary to determine absorbed dose in a medium using a calibration factor based on exposure or kerma in air. Attenuation and scattering effects of 60 Co gamma rays in the ionization chamber wall and build-up cap, as well as their non-equivalence to air, were studied with an OFS ionization chamber (Delrin wall) and a set of build-up caps specially built for this purpose. Results for a specific material were plotted as functions of wall and cap total thickness, extrapolated to zero wall thickness, then corrected for mean centre of electron production in the wall (= 0.136 g cm -2 ). Correction factors for a specific thickness were analysed in relation to cap material, and to relative responses compared with values calculated by using AAPM, SEFM and IAEA formalisms for cap effects. A Monte Carlo calculation was performed to compare the experimental and theoretical values. Calculations showed an agreement within 0.1% with experimental values and a wall effect of approximately 1.6%. (Author)

  20. Mantle treatment of Hodkin's disease with 60Co gamma rays

    International Nuclear Information System (INIS)

    Svahn-Tapper, G.

    1979-01-01

    60 Co mantle beams were used in the radiation treatment of patients| with Hodgkin's disease. A technique using beam-flattening filters is described. The dosimetry was based on dose plans drawn up manually for each patient. The good dosimetric accuracy of the method was verified by in vivo measurements of absorbed dose at the oesophagi of 60 patients. Split-course treatment with 40 Gy was given in 27 fractions over 71 days. Results and side-effects in 90 patients are analyzed. The local recurrence rate was 3 %. (author)

  1. Simulation study on unfolding methods for diagnostic X-rays and mixed gamma rays

    International Nuclear Information System (INIS)

    Hashimoto, Makoto; Ohtaka, Masahiko; Ara, Kuniaki; Kanno, Ikuo; Imamura, Ryo; Mikami, Kenta; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    A photon detector operating in current mode that can sense X-ray energy distribution has been reported. This detector consists of a row of several segment detectors. The energy distribution is derived using an unfolding technique. In this paper, comparisons of the unfolding techniques among error reduction, spectrum surveillance, and neural network methods are discussed through simulation studies on the detection of diagnostic X-rays and gamma rays emitted by a mixture of 137 Cs and 60 Co. For diagnostic X-ray measurement, the spectrum surveillance and neural network methods appeared promising, while the error reduction method yielded poor results. However, in the case of measuring mixtures of gamma rays, the error reduction method was both sufficient and effective. (author)

  2. Genomic instability induced by 60Co γ ray radiation in normal human liver cells

    International Nuclear Information System (INIS)

    Gen Xiaohua; Guo Xianhua; Zuo Yahui; Wang Xiaoli; Wang Zhongwen

    2007-01-01

    Objective: To explore the genomic instability induced by 60 Co γ rays. Methods: The cloning efficiency and micronucleus efficiency of normal human liver cell irradiated by 60 Co γ rays were detected, and the method of single cell gel electrophoresis (SCGE) was carried out to measure DNA chains damage. The fast-growing cells were divided into different dose-groups and then irradiated by 60 Co γ rays. After 40 populations doubling, the progenies were secondly irradiated with 2 Gy 60 Co γ rays. Results: The cloning efficiency decreased with the increase of doses after the initial irradiation. After the survival cells were given second irradiation, both results of SCGE and micronucleus frequency showed that the second damage was correlated with the original irradiation doses. Conclusions: 60 Co γ rays can not only induce the immediate biological effects in liver cells, but also lead to the genomic instability in the descendants that leads to an enhanced frequency of genetic changes occurring among the progeny of the original irradiated cell. The expanding effect of second event helps to study the genomic instability. (authors)

  3. Effect of (/sup 60/cobalt) gamma rays on growth and root rot diseases in mungbean (vigna radiata L.)

    International Nuclear Information System (INIS)

    Ikram, N.; Dawar, S.; Zaki, M.J.; Abass, Z.

    2010-01-01

    Present investigation showed that gamma rays influences suppressive effect on root rot fungi such as Macrophomina phaseolina (Tassi) Goid, Rhizoctonia solani Kuhn and Fusarium spp., and inducive effect on growth parameters of mung bean (Vigna radiata L.). Seeds of mung bean were treated with gamma rays (/sup 60/Cobalt) at time periods of 0 and 4 minutes and stored for 90 days at room temperature to determine its effect on growth parameters and infection of root infecting fungi. All treatments of gamma rays enhanced the growth parameters as compared to untreated plants. Infection of M. phaseolina, R. solani and Fusarium spp., were significantly decreased on mung bean seeds treated with gamma rays. Gamma rays significantly increased the growth parameters and controlled the root rot fungi up to 90 days of storage of seeds. (author)

  4. Effect of Co-60 irradiation on hyperimmune antimeningococcus globulins-gamma

    International Nuclear Information System (INIS)

    Galguera, M.; Le Riverand, E.; Padron, S.

    1990-01-01

    Globulins-gamma from voluntary blood donors immunized with the Cuban BC antimeningococcus vaccine is now being used in our country for the treatment of the meningococcus disease. This study of the effect of Co-60 irradiation on antimeningococcus globulins-gamma was carried out to try to eliminate the inconvenience shown by the traditionally used sterilization procedures (losses in the filter and persistence of viral contamination). globulins-gamma was obtained by ethanol fractionation and was irradiated at a different dose in solution with different stabilizers and it was also lyophilized. Results of the chemical controls carried out lead to the conclusion that it is possible to use radiosterilization on this product in a lyophilized form. The preservation of bactericidal activity, even after the highest irradiation doses, confirms the above mentioned. 13 refs

  5. Effect of Co-60 gamma radiation on optical, dielectric and mechanical properties of strontium L-ascorbate hexahydrate NLO crystal

    Science.gov (United States)

    Dileep, M. S.; Suresh Kumar, H. M.

    2018-04-01

    A potentially useful nonlinear optical semi-organic single crystal of strontium L-ascorbate hexahydrate (SLAH) was grown by solution growth slow evaporation technique at room temperature. The grown crystal is semi transparent, yellowish in color with monoclinic crystal system having space group P21 and is stable up to 198 °C. Further, SLAH crystals were irradiated with gamma rays produced by 60Co with different doses of 10 KGy, 30 KGy and 50 KGy at room temperature and then studied the effect of gamma-rays on dielectric properties, optical absorption, microhardness and SHG efficiency. The absorption study reveals that the absorbance of the grown crystal is appeared to be low throughout the visible region with a lower cutoff wavelength of 277 nm and these parameters are not affected upon gamma irradiation. The luminescence intensity of the crystal is also not affected by the irradiation. There is noticeable changes were observed in dielectric properties and hardness of the materials for different doses of gamma irradiation. The second harmonic generation (SHG) efficiency of the grown crystal is 0.54 times that of the KDP crystal and is decreased moderately by increasing the dosage of gamma irradiation.

  6. Re-evaluation of structural shielding designs of X-ray and CO-60 gamma-ray scanners at the Port of Tema, Ghana

    International Nuclear Information System (INIS)

    Ofori, K.

    2011-07-01

    This research work was conducted to re-evaluate the shielding designs of the 6 MeV x-ray and the 1.253 MeV Co-60 gamma ray scanners used for cargo-containerized scanning at the Port of Tema. These scanners utilize ionizing radiation, therefore adequate shielding must be provided to reduce the radiation exposure of persons in and around the facilities to acceptable levels. The purpose of radiation shielding is to protect workers and the general public from the harmful effects of ionizing radiation. Investigations on the facilities indicated that after commissioning, no work had been carried out to re-evaluate the shielding designs. However, workloads have increased over time neccessitating review of the installed shielding. There has been introduction of scanner units with higher radiation energy (as in the case of the x-ray scanner) posibily increasing dose rates at various location requiring review of the shielding. New structures have been dotted around the facilities without particular attention to their distances and locations with respect to the radiation source. Measurements of distances from the source axes to the points of concern for primary and leakage barrier shielding; source to container and container to the points of concern for scattered radiation shielding were taken. The primary and secondary thicknesses required for both scanners were determined based on current operational parameters and compared with the thickness constituted during the construction of the facilities. Calculated and measured dose rate beyond the shielding barriers were used to established the adequacy or otherwise of the shielding employed by the shielding designers. Values obtained fell below the 20 µSv/hr specified by NCRP 151 (2005) which showed that the primary and secondary shields of both facilities were adequate requiring no additional shielding. (author)

  7. Study on the resistance of haloferax radiotolerans, an extreme Halophilic archaebacterium from Uromia lake against ultraviolet (UV) light and 60Co gamma-rays

    International Nuclear Information System (INIS)

    Asgarni, E.; Shirzad, M.; Soudi, M. R.; Shahmohammadi, H. R.; Falsafi, T.

    2006-01-01

    In this work, the capacity of an extreme halophilic archaebacterium, isolated from Uromia lake, Haloferax radiotolerans to withstand the lethal effects of ultraviolet light (UV),and 60 Co r-rays has been studied. The resistibility of this organism against the DNA-damaging agents was evaluated by calculating of the survival fractions at different dose rates of W and 60 Co r-rays radiations and compared with those of Escherichia coli B/r (a radioresistant strain of E. coli). D 37 values for Haloferax radiotolerans and E. coli B/r were 23 1, and 9 J/m 2 , respectively, by exposure to the UV light. They were 645, and 99 Gy, respectively, by exposure to 60 Co r-rays. Against these agents, Haloferax radiotolerans shows much more resistance compare to that of E. coli B/r. This is categorized as the first report of resistibility in the member of Archaea

  8. Gamma rays from the interstellar medium

    International Nuclear Information System (INIS)

    Bloemen, J.B.G.M.

    1985-01-01

    This thesis describes new gamma-ray views on cosmic rays and the interstellar medium. The author describes the COS-B data base and the pre-launch and in-flight calibration data used for all analyses. Diffuse galactic gamma radiation (> 50 MeV) may be either a result of cosmic-ray-matter interactions, or of the cosmic-ray electrons with the interstellar radiation field (mainly at optical and infrared wavelengths), through the inverse-Compton process. A detailed comparison between the gamma-ray observations of the large complex of interstellar clouds in Orion and Monoceros and the CO and HI surveys of this region is given. It gives insight into the cloud penetration of cosmic rays and in the relation between CO detections and molecular hydrogen column densities. Next, the radial distribution of gamma rays in the Galaxy is studied, as well as the galactic centre (more precisely, the central 400 pc), which contains a large concentration of CO molecules. The H 2 /CO abundance and the cosmic-ray density in the galactic centre are discussed and compared to the findings for the galactic disk. In various analyses in this thesis a likelihood-ratio method is applied for parameter estimation and hypothesis testing. A general description of this method is added as an appendix. (Auth.)

  9. Effects of Co60 gamma radiation on the immunogenic and antigenic properties of Bothrops jararacussu venom

    International Nuclear Information System (INIS)

    Spencer, Patrick J.; Nascimento, Nanci do; Rogero, Jose R.

    1997-01-01

    Ionizing radiation has been successfully employed to attenuate animals toxins and venoms for immunizing antisera producing animals. However, the radiation effects on antigenicity and immunogenecity have not yet been elucidated. In the present work, we investigated the effects of gamma rays on the antigenic and immunogenicity have not yet been elucidated. In the present work, we investigated the effects of gamma rays on the antigenic and immunogenic behaviour of Bothrops jararacussu venon. Venom samples (2mg/ml in 150 mM NaCl) were irradiated with 500, 1000 and 2000 Gy of 60 Co gamma rays. These samples were submitted to antigen capture ELISA on plates coated with commercial bothropic antiserum. Results suggest a loss of reactivity of the 1000 and 2000 Gy irradiated samples. Antibodies against native and 2000 Gy irradiated venoms were produced in rabbits. Both sera able to bind native venom with a slightly higher titer for anti-irradiated serum. These data suggest that radiation promoted structural modification on the antigen molecules. However since the antibodies produced against irradiated antivenom were able to recognize native venom, there must have been preservation of some antigenic determinants. It has already been demosntrated that irradiation of proteins leads to structural modifications and unfolding of the molecules. Our data suggest that irradiation led to conformational epitopes destruction with preservation of linear epitopes and that the response against irradiated venom may be attributed to these linear antigenic determinants. (author). 8 refs., 3 figs

  10. Lunar based gamma ray astronomy

    International Nuclear Information System (INIS)

    Haymes, R.C.

    1985-01-01

    Gamma ray astronomy represents the study of the universe on the basis of the electromagnetic radiation with the highest energy. Gamma ray astronomy provides a crucial tool for the understanding of astronomical phenomena, taking into account nucleosynthesis in supernovae, black holes, active galaxies, quasars, the sources of cosmic rays, neutron stars, and matter-antimatter annihilation. Difficulties concerning the conduction of studies by gamma ray astronomy are related to the necessity to perform such studies far from earth because the atmosphere is a source of gamma rays. Studies involving the use of gamma ray instruments in earth orbit have been conducted, and more gamma ray astronomy observations are planned for the future. Imperfections of studies conducted in low earth orbit could be overcome by estalishing an observatory on the moon which represents a satellite orbiting at 60 earth radii. Details concerning such an observatory are discussed. 5 references

  11. Action of minute dosis of gamma rays on gestation of mice

    International Nuclear Information System (INIS)

    Templier, J.; Maudouyt, M.A.; Charpenteau, M.; Bonnet, J.

    1978-01-01

    Female mice were irradiated with 10 rads of 60 Co gamma ray, 7 hours after mating. This low dose induces a decrease in implantation number, and alive foetus number and is followed by a lower number of corpora lutea. These results to seem to show an effect of gamma irradiation on ovary and embryonic development [fr

  12. Thermoluminescence of Simulated Interstellar Matter after Gamma-ray Irradiation

    OpenAIRE

    Koike, K.; Nakagawa, M.; Koike, C.; Okada, M.; Chihara, H.

    2002-01-01

    Interstellar matter is known to be strongly irradiated by radiation and several types of cosmic ray particles. Simulated interstellar matter, such as forsterite $\\rm Mg_{2}SiO_{4}$, enstatite $\\rm MgSiO_{3}$ and magnesite $\\rm MgCO_{3}$ has been irradiated with the $\\rm ^{60}Co$ gamma-rays in liquid nitrogen, and also irradiated with fast neutrons at 10 K and 70 K by making use of the low-temperature irradiation facility of Kyoto University Reactor (KUR-LTL. Maximum fast neutron dose is $10^{...

  13. Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Bernhard [National Institute of Technology, Rio de Janeiro (Brazil)

    1960-06-15

    The Compton current produced by X-rays and {gamma}-rays in the 0.3 to 3 MeV range is proportional to the radiant energy flux. Therefore the intensity of the current can be used as a measure of radiation dose. The present paper describes a radiation receiver and electrical measuring system suitable for Compton current measurements and results obtained with this device under irradiation from a 2000 curie Co{sup 60} source. (author) [French] Le courant de Compton produit par des rayons X et {gamma} dans le domaine d'energies compris entre 0,3 et 3 MeV est proportionnel au flux d'energie rayonnante. C'est pourquoi l'intensite du courant peut servir de mesure de la dose de rayonnements. Le memoire decrit un ensemble, appareil recepteur de rayonnements et appareil de mesure electrique, permettant de mesurer le courant de Compton et il expose les resultats obtenus, au moyen de ce dispositif, sous irradiation par une source de Co{sup 60} de 2000 curies. (author) [Spanish] La corriente de Compton producida por rayos X y rayos {gamma} de energia comprendida entre 0,3 y 3 MeV es proporcional al flujo de energia radiante. Por consiguiente, la intensidad de la corriente puede servir para medir la dosis de radiacion. En este trabajo se describen un receptor de radiaciones y un sistema de medicion electrica apropiados para determinar la intensidad de la corriente de Compton, asi como los resultados obtenidos mediante este dis- positivo cuando se irradia con una fuente de Co{sup 60} de 2000 curies. (author) [Russian] Komptonovskij potok, obrazuemyj rentgenovskim i luchami i {gamma}-luchami v predelakh ot 0,3 do 3 mehv, proportsionale n potoku luchistoj ehnergii. Poehtomu intensivnost' potoka mozhet byt' ispol'zovana dlya izmereniya dozy radiatsii. V nastoyashchem dokumente opisyvayutsya radiatsionny j priemnik i ehlektricheskaya izmeritel'naya sistema, prigodnye dlya izmerenij s pomoshch'yu komptonovskog o potoka, i rezul'taty, poluchennye s pomoshch'yu ehtogo ustrojstva v khode

  14. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  15. Multi-isotopic gamma-ray assay system for alpha-contaminated waste

    International Nuclear Information System (INIS)

    Close, D.A.; Pratt, J.C.; Caldwell, J.T.; Kunz, W.E.; Schultz, F.J.; Haff, K.W.

    1983-01-01

    The capability of an existing segmented gamma-ray system is being expanded for the analysis of alpha-contaminated waste drums. A cursory assay of 114 transuranic waste drums of 208-l capacity has been made. Analysis of these data indicates a detection limit better than 100 nCi/g of waste for 237 Np/ 233 Pa, 239 Pu, 241 Am, 243 Am/ 239 Np, 60 Co, 125 Sb, 134 137 Cs, and 154 Eu. A pending Code of Federal Regulation (10CFR61) stipulates that the nuclear industry quantify not only its transuranic waste, but also certain beta- and gamma-ray-emitting fission products. An assay system based on gamma-ray spectroscopy is the only system that can meet this requirement for the fission products

  16. Mutagenesis of the somaclones in vitro of cut roses by 60Co γ-rays irradiation

    International Nuclear Information System (INIS)

    Qu Suping; Su Yan; Wang Lihua; Tang Kaixue; Wang Jihua; Zhang Hao

    2009-01-01

    Mutagenesis of cut rose in vitro irradiated by 60 Co γ-rays was studied. The callus of leaves and regenerations adventitious bud was used as the explants for mutagenesis. Effect of 60 Co γ-rays irradiation on the callus's regeneration rate, adventitious bud's multiplication rate and vegetal status were studied. The results showed that the regeneration frequency of callus was decreased by 60 Co γ-rays irradiation. The regenerations adventitious bud was the better experimental materials compared with the callus of leaves. The lethal dose was 122 Gy and the semi-lethal dose was 76 Gy according to the regression equation. The appropriate dose on adventitious bud by irradiation rays was 50-60 Gy. (authors)

  17. Effects of 60Co gamma radiation on crotamine

    Directory of Open Access Journals (Sweden)

    Boni-Mitake M.

    2001-01-01

    Full Text Available Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (pI 10.3 from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (LD50. Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it.

  18. Displacement correction factor versus effective point of measurement in depth dose curve measurements at {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Bruna, A [Universidad Nacional, Cordoba (Argentina). Facultad de Matematica, Astronomia y Fisica; Velez, G R [Hospital San Roque, Cordoba (Argentina). Dept. de Radioterapia; Brunetto, M [Centro Medico Rivado Dean Funes, Cordoba (Argentina)

    1996-08-01

    The discrepancies in data sets of values of the Displacement Factor p{sub d} recommended by different codes of practices for calibration purpose still demand further investigation to clarify this point. In this paper, we propose an experimental method to determine the displacement factor for cylindrical ionization chambers (thimble chambers) in photon beams. Measurements of p{sub d} for several depths were performed for {sup 60}Co gamma rays. From these results we calculated the shift of the effective point of measurement (z-z{sub eff}) for different depths. The results obtained in this work shown: (a) there is no significant change in p{sub d} from 2 cm to 17 cm of depth in water; (b) the value of p{sub d} for a ion-chamber Farmer type (inner radius r = 3.15 cm) is p{sub d} 0.988; (c) the shift of the effective point of measurement has a smooth variation with depth; (d) the value of (z-z{sub eff}) at the recommended calibration depth for {sup 60}Co beams (5 cm) is 0.6r (with r: inner radius of the chamber). The result (b) confirms the value of p{sub d} suggested by the SEFM and NACP protocols and differs with that of the AAPM. The value obtained for (z - z{sub eff}) (d) is very closed to that recommended by the IAEA TRS-277. Finally, the results (a) and (c) suggest that it should be preferable to use the displacement factor instead of effective point of measurement to perform measurements of depth dose curves, since the use of z{sub eff} should take into account its dependence on depth. (author). 7 refs, 4 figs.

  19. Study on the viability of peach and apple pollen treated with gamma rays 60Co

    International Nuclear Information System (INIS)

    Filev, K.; Angelov, A.

    1976-01-01

    Pollen from Marygold peach and from Golden Delicious apple varieties was treated with gamma-rays at rates of 0.5, 1.5, 10.0, 50.0, 100, 200, 300, 400 and 500 kR, the irradiation intensity being 1350 r/min. Results point to a different influence of gamma-rays irradiation on the pollen germination. Apple pollen proved more radiosensitive. Least dose of o.5 kR exerted a stimulative effect in the pollen germination. As the irradiation dose rcse, the germination percentage declined. Doses of over 400 kR destroyed completely pollen viability in both fruit species. A linear semi-logarithmical dependence was ascertained between the irradiation rate and pollen germination. 5 and 10 kR proved most suitable for the purposes of the experimental mutagenesis at peach and apple pollen irradiation. (author)

  20. Effects of 2.0 Gy of 60Co gamma rays irradiation on rat embryos

    International Nuclear Information System (INIS)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body 60 Co γ ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by 60 Co γ ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.)

  1. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J; Mijares O, P; Garcia A, J M [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  2. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J.; Mijares O, P.; Garcia A, J.M. [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  3. Dose response curve for prematurely condensed chromosome fragments of human lymphocytes after 60Coray exposure

    International Nuclear Information System (INIS)

    Gao Jinsheng; Zheng Siying; Bao Hong

    1992-06-01

    The dose-effect relationship of premature condensed chromosome fragments in human lymphocytes irradiated by 60 Co gamma ray was studied by PCC method (premature condensed chromosomes). In addition, The conventional cellular genetics method was also used in the study. The response curve of both methods can represented by two linear equations. The ratio of two slopes, K PCC /K M1 , is about 28. Comparing with conventional method, the PCC method has many advantages such as faster, simpler, more sensitive and accurate. The PCC method used in the studying of radiation damage is also discussed

  4. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 γ-ray beams. Either the Klein--Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source--surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  5. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  6. Study of uptake and endocytosis of gamma rays-irradiated crotoxin by mice peritoneal macrophages

    International Nuclear Information System (INIS)

    Cardi, Bruno Andrade

    1999-01-01

    The purpose was to investigate the uptake and endocytosis of 2000 Gy 60 Co irradiated crotoxin through mouse peritoneal macrophages, correlating with native one and another non related protein, the ovalbumin. Native (CTXN) or 2000 Gy 60 Co γ-rays (dose rate 540 Gy/hour) irradiated crotoxin (CTXI) or ovalbumin processed of same manner (OVAN - OVAI) were offered to mouse peritoneal macrophages and their uptake was evaluated by immunohistochemistry and quantitative in situ ELISA. The involvement of scavenger receptors (ScvR) was evaluated by using blockers drugs (Probuco-PBC or Dextran Sulfate - SD) or with nonspecific blocking using fetal calf serum (FBS). The morphology and viability of macrophages were preserved during the experiments. CTXI showed irradiation-induced aggregates and formation of oxidative changing were observed on this protein after gamma rays treatment. By immunohistochemistry we could observe heavy stained phagocytic vacuole on macrophages incubated with CTXI, as compared with CTXN. Quantitatively by in situ ELISA, the sema pattern was observed, displaying a 2-fold CTXI incorporation. In presence of PBC or SD we could find a significant decrease of CTXI uptake but not of CTXN. However the CTXN uptake was depressed by FBS, not observed with CTXI. OVA, after gamma rays treatment, underwent a high degradation suffering a potent incorporation and metabolism by macrophages, with a major uptake of OVAI in longer incubation (120 minutes). Gamma rays ( 60 Co) produced oxidative changes on CTX molecule, leading to a uptake by ScvR-mice peritoneal macrophages, suggesting that the relation antigen-presenting cells and gamma rays-modified proteins are responsible for the better immune response presented by irradiated antigens. (author)

  7. Assessment of shielding integrity of Co-60 gamma irradiation-ray scanner at Aflao Border, Ghana

    International Nuclear Information System (INIS)

    Agbemafo, Edwin Capacity

    2016-07-01

    This study examines the current state of the shielding integrity of the 38.7 TBq Co-60 gamma ray scanner with an average energy of 1.25 MeV operated by NICK TC Scan Limited, which has been in use for destination inspection at Aflao Border of Ghana, for the past six years, (2010-2016). The facility uses a high energy ionizing radiation in its operation; therefore continuous adequacy of the installed biological shielding is critical to the protection and safety of the workers and the general public. The workload of the facility has increased since its commissioning, requiring the review of the status of the installed shielding. Theoretical calculations for dose rates and barrier thicknesses based on tenth – value layer (TVL) concept and NCRP 151, 2005 recommendations, were done around the scanning facility using the current operational data. The results were then compared with the measured dose rates and the shielding thickness constituted during the commissioning stage, and international standards. Calculated dose rate at commissioning state ranges from 0.6μSv/hr to 2.4μSv/hr with an average dose rate of 1.43μSv/hr and that of the current operational state ranges from 1.1μSv/hr to 2.6μSv/hr with an average dose rate of 1.54μSv/hr, indicating an increase of 7.9%. Even though the dose rates were all below the recommended dose limit of 20μSvh"-"1 by NCRP, there has been an increase in dose to the staff and the general public. It has been observed that, the workload has increased three-fold from the commissioning stage to current operational state over the past six years. The assessment done on the installed shielding using the current operational data indicates that the shielding is inadequate in providing protection for the general public and the workers against X-ray radiation source of energy of at least 6MeV, and therefore the facility in its current state cannot be used to house a linear accelerator of energy up to 10MeV. (au)

  8. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H.; Jaervinen, H.; Grimbergen, T.W.M.; Grindborg, J.E.; Chauvenet, B.; Czap, L.; Ennow, K.; Moretti, C.; Rocha, P.

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use. (author)

  9. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H; Jaervinen, H; Grimbergen, T W M; Grindborg, J-E; Chauvenet, B; Czap, L; Ennow, K; Moretti, C; Rocha, P

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use

  10. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.

    Science.gov (United States)

    Jaradat, Adnan K; Biggs, Peter J

    2007-05-01

    The calculation of shielding barrier thicknesses for radiation therapy facilities according to the NCRP formalism is based on the use of broad beams (that is, the maximum possible field sizes). However, in practice, treatment fields used in radiation therapy are, on average, less than half the maximum size. Indeed, many contemporary treatment techniques call for reduced field sizes to reduce co-morbidity and the risk of second cancers. Therefore, published tenth value layers (TVLs) for shielding materials do not apply to these very small fields. There is, hence, a need to determine the TVLs for various beam modalities as a function of field size. The attenuation of (60)Co gamma rays and photons of 4, 6, 10, 15, and 18 MV bremsstrahlung x ray beams by concrete has been studied using the Monte Carlo technique (MCNP version 4C2) for beams of half-opening angles of 0 degrees , 3 degrees , 6 degrees , 9 degrees , 12 degrees , and 14 degrees . The distance between the x-ray source and the distal surface of the shielding wall was fixed at 600 cm, a distance that is typical for modern radiation therapy rooms. The maximum concrete thickness varied between 76.5 cm and 151.5 cm for (60)Co and 18 MV x rays, respectively. Detectors were placed at 630 cm, 700 cm, and 800 cm from the source. TVLs have been determined down to the third TVL. Energy spectra for 4, 6, 10, 15, and 18 MV x rays for 10 x 10 cm(2) and 40 x 40 cm(2) field sizes were used to generate depth dose curves in water that were compared with experimentally measured values.

  11. Evaluation of fruit productivity and quality in Hass avocado submitted to 60Co gamma radiation

    International Nuclear Information System (INIS)

    Cruz T, E. De la; Ibanez P, J.; Mijares O, P.; Garcia A, J.M.

    1999-01-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with 60 Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO 2 /kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  12. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  13. Gamma-ray emission spectra from spheres with 14 MeV neutron source

    International Nuclear Information System (INIS)

    Yamamoto, Junji; Kanaoka, Takeshi; Murata, Isao; Takahashi, Akito; Sumita, Kenji

    1989-01-01

    Energy spectra of neutron-induced gamma-rays emitted from spherical samples were measured using a 14 MeV neutron source. The samples in use were LiF, Teflon:(CF 2 ) n , Si, Cr, Mn, Co, Cu, Nb, Mo, W and Pb. A diameter of the sphere was either 40 or 60 cm. The gamma-ray energy in the emission spectra covered the range from 500 keV to 10 MeV. Measured spectra were compared with transport calculations using the nuclear data files of JENDL-3T and ENDF/B-IV. The agreements between the measurements and the JENDL-3T calculations were good in the emission spectra for the low energy gamma-rays from inelastic scattering. (author)

  14. The optimal dosage of 60 co gamma irradiation for obtaining salt gland mutants of exo-recretohalophyte limonium bicolor (bunge) o. kuntze

    International Nuclear Information System (INIS)

    Yuan, F.; Chen, M.; Yang, J.; Wang, B.

    2015-01-01

    Limonium bicolor (Bunge) O. Kuntze is a typical exo-recretohalophyte with multi-cellular salt glands. It is often used to improve saline-alkali soil. Seeds of L. bicolor were treated with different doses of 60 Co gamma irradiation to determine the LD50 for 60 Co gamma irradiation; the goal was to produce a relatively high number of mutants in salt gland development and salt secretion with a relatively low level of mortality. 60 Co gamma irradiation did not greatly affect germination, but an increase in gamma dose prevented the development of true leaves and reduced the percentage of seedlings that emerged from soil. The LD50 for 60 Co gamma irradiation was 120 Gy. Two mutants (few and many) were obtained under the LD50 using the screening methods - differential interference contrast microscope and leaf discs excretion model. Compared with the wild type, few and many had mutation in salt gland development, and many showed lower salt secretion rate per single salt gland than WT. These mutants would provide insight into the molecular mechanisms of salt gland development and salt secretion and into the development of salt-tolerant crop plants. (author)

  15. {sup 60}Co {gamma} irradiation effects on the current-voltage (I-V) characteristics of Al/SiO{sub 2}/p-Si (MIS) Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey)]. E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey); Buelbuel, M.M. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey)

    2006-12-01

    It is well known that the exposure of any semiconductor surfaces to the {sup 60}Co {gamma}-ray irradiation causes electrically active defects. To investigate the effect of {gamma}-ray irradiation dose on the electrical characteristics of metal-insulator-semiconductor (MIS) Schottky diodes, the fabricated devices were exposed to {gamma} radiation at a dose of 2.12 kGy/h. The total dose range was from 0 to 450 kGy at room temperature. The density of interface states N {sub ss} as a function of E {sub ss}-E {sub v}, the values of series resistance R {sub s} and the bias dependence of the effective barrier height {phi} {sub e} for each dose were obtained from the forward bias I-V characteristics. Experimental results show that the {gamma}-irradiation gives rise to an increase in the zero bias barrier height {phi} {sub BO}, as the ideality factor n, R {sub s} and N {sub ss} decreases with increasing radiation dose.

  16. Effect of 60Co γ-ray irradiation on human platelets

    International Nuclear Information System (INIS)

    Wu Guoxin; Zhao Yiming; Ruan Changgeng

    1992-01-01

    Human platelet-rich plasma was irradiated with various doses (0, 1.25, 2.5, 5, 10, 20, 40 Gy) of 60 Co γ-rays in order to observe the changes of metabolites and the release of internal substance of platelets. At the dose of 5 Gy, alpha-granule membrane protein (GMP-140) molecules expressed on the surface of platelets increased significantly, while glycoproteins (GP) Ib and IIIa did not change apparently; at the dose as low as of 2.5 Gy, thromboxane B 2 production in plasma was remarkably increased; and, at the dose of over 5 Gy, the concentration of von Willebrand factor increased with increasing doses as in the case of GMP-140 molecules. These results indicate that platelets can be activated in vitro when the dose of 60 Co γ-rays exceeds 5 Gy

  17. Effect of acute sup(60)Co-gamma-irradiation on the in vivo lipid peroxidation in experimental animals

    International Nuclear Information System (INIS)

    Ronai, Eva; Benkoe, Gy.

    1984-01-01

    The effect of sublethal (6.0 Gy) and LDsub(50/30) (9.0 Gy) doses of sup(60)Co-gamma-irradiation on malondialdehyde (MDA) level was studied in rats. The findings suggest that in the organs investigated (brain, liver, spleen, kidneys, testicles, stomach, small intestines) acute sup(60)Co gamma-irradiation increased the formation of MDA, the main product of lipid peroxidation, in a time-related manner to an extent characteristic of the organ investigated. Differences in the degree and temporal development of the changes allow some conclusions as to the radiosensitivity of individual organs. On this basis it can be assumed that the increase in MDA level caused by irradiation considerably contributes to the development of certain symptoms of radiation sickness. (author)

  18. Application of 60Co γ-ray irradiated polystyrene microplate for anti-HCV ELISA

    International Nuclear Information System (INIS)

    Feng Bo; Zeng Hongyan; Tang Yufang; Wang Lu

    2005-01-01

    In order to explore the effect of 60 Co γ-ray irradiation on minor polypeptides absorption of polystyrene microplate, an indirect ELISA detection of anti-HCV was established, 60 Co γ-ray irradiated polystyrene microplates and the controls (without irradiation or UV-irradiated) were applied to absorb recombinant HCV antigens respectively. Cooperated with Bovine antihuman IgG labelled HRP, their related indices of sensitivity, specificity, homogeneity and stability were determinate. The results indicated that, optimum dose of the γ-ray irradiation is 8 kGy, and compared with the controls, detection sensitivity and homogeneity of the polystyrene microplate irradiated to 8 kGy could be improved markedly. (authors)

  19. Study of the ionization of alkane-electron scavenger reactant mixtures irradiated by 60Co gamma rays

    International Nuclear Information System (INIS)

    Bonnet, Jacques.

    1977-01-01

    This study deals with ionization of alkane-electron scavenger reactant mixtures, irradiated by 60 Co γ-rays. It is shown that the extrapolated free-ion yields (extrapolated yield method) decrease with the reactant concentration. On the basis of ONSAGER model and theoretical treatment of MOZUMDER, the cross sections of epithermal electron attachment in hexane, cyclohexane, 2,2-dimethylbutane, cyclopentane, 2,2,4-trimethylpentane for CCl 4 , C 7 F 14 , C 6 H 5 Br, C 6 H 5 Cl, C 6 F 14 , (C 6 H 5 ) 2 are determined. A comparison between gas-phase and liquid-phase cross sections is established [fr

  20. Determination of high level absorbed dose in a 60Co gamma ray field with ionization chambers

    International Nuclear Information System (INIS)

    Zhongying Li; Benjiang Mao; Lu Zhang

    1995-01-01

    This paper relates to the principles and methods for determining the absorbed dose of high energy photons radiation with ionization chambers, and its shows the doserate results of high level 60 Co γ-rays in water measured with Farmer chambers. The results with two kinds of chambers at a same point are consistent within 0.3%, and the total uncertainty is less than ± 4%. In the domestic intercomparison on determining high level absorbed dose in which 12 laboratories participated, the deviation of our result from the mean result of the intercomparison is -0.04% [Chen Yundong (1992). Summing up report on a high level absorbed dose intercomparison (in Chinese)]. (author)

  1. Determination of radionuclides for river sediment CRM with HPGe gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Tan Jinbo; Hao Runlong; Tang Zhenxin

    1994-01-01

    The authors described the method and results for determination of seven radionuclides: 238 U, 235 U, 226 Ra, 232 Th, 40 K, 60 Co and 137 Cs in the river sediment Certified Reference Material (CRM) using a HPGe gamma-ray spectrometer. The accuracy and reliability of measurement results were improved through varieties of techniques, which include: precise calibration of the gamma-ray spectrometer, coincidence summing correction and interference peak correction, two kinds of peak analysis methods (TPA and function fit), and utilization of as many as possible characteristic gamma-rays. Present measurement results for the seven radionuclides were in agreement with the verification results of the CRM with 1 σ or 2σ uncertainty, and its relative deviation were in the range of +1.0%--6.5%

  2. Effects of {sup 60} Co gamma radiation on crotamine

    Energy Technology Data Exchange (ETDEWEB)

    Boni-Mitake, M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Radioprotecao Ocupacional; Costa, H.; Spencer, P.J. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Bioengenharia; Rogero, J.R [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Diretoria de Materiais; Vassilieff, V.S. [UNESP, Botucatu, SP (Brazil). Instituto de Biociencias. Ceatox - Centro de Assistencia Toxicologica]. E-mail: mbmitake@net.ipen.br

    2001-12-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (p I 10.3) from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60 Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (Ld50). Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it. (author)

  3. Degradation Of α-Chitosan By Combined Treatment With Hydroperoxide And Gamma 60Co Radiation

    International Nuclear Information System (INIS)

    Nguyen Quoc Hien; Dang Van Phu; Bui Phuoc Phuc; Ha Thuc Huy

    2008-01-01

    Chitosan samples prepared from shrimp shell (α-chitosan) with degree of deacetylation (DD) of 70, 84 and 94% were treated with H 2 O 2 1.5% at room temperature for degradation. The oxidative chitosan was irradiated by gamma 60 Co radiation for further reduction of molecular weight. Viscosity-average molecular weight of chitosan was measured by capillary viscometer. Results showed that H 2 O 2 was an effective reagent for chitosan degradation. Radiation degradation yield (G s ) increased for chitosan with higher DD. Interestingly Gs-values for oxidative degraded chitosan were found out of 0.96, 5.73 and 7.80 scissions/100 eV that were remarkably higher compared to 0.20, 1.05 and 1.69 scissions/100 eV for initial chitosan with DD 70, 84 and 94%, respectively. Based on results obtained it can be concluded that combined treatment with hydroperoxide and gamma 60 Co radiation was remarkably effective for degradation of chitosan. (author)

  4. Comparative experiments for tube agglutination test of pullorum antiserum with gamma ray Co/sup 60/ irradiated salmonella pullorum

    Energy Technology Data Exchange (ETDEWEB)

    Seo, B K [City Univ. of Seoul, Seoul (Republic of Korea)

    1976-01-01

    An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmunized rabbit antiserum was compared. And the following results were obtained and summarized. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was better than another both formalized and heated antigen. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at 37/sup 0/C. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320 approximately 640x.

  5. SU-E-T-94: An Advanced Rotating Gamma Ray System for Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Chibani, O; Li, J; Chen, L [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: Co-60 beams have unique dosimetric properties that are ideally suited for cranial treatments. Co-60 sources with cone-shaped collimators provide conformal dose distributions allowing for ablative treatments with rapid dose falloff to spare nearby critical structures. This work investigates a novel, image-guided, rotational Gamma ray system that provides both superior dose conformity/gradient and accurate stereotaxy for stereotactic radiosurgery (SRS). Methods: The SupeRay system (Cyber Medical Corp., China) consists of a rotating source chamber containing 30 gamma sources focusing at the isocenter with 4 collimators measuring 3, 4, 8 and 16mm in diameter. A novel switch design enables the 30 Gamma sources to be turned off at any arbitrarily selected 60° interval in order to avoid critical structures. The 3D treatment couch provides automatic treatment positioning between individual shots and the kV imaging system provides orthogonal images with a spatial resolution of 0.24mm to facilitate target localization. Monte Carlo simulations were used to compute dose distributions and compare with measurements and other Gamma ray SRS systems. Results: Monte Carlo results confirmed the SupeRay design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient is similar to or slightly better than that of the Elekta Gamma Knife. The penumbra in the (x,y,z) direction was (7.38mm,7.38mm,3.86mm) for the 16mm collimator, (4.83mm,4.83mm,3.12mm) for the 8mm collimator, and (3.03mm,3.03mm,2.38mm) for the 4mm collimator, respectively, on the SupeRay system while it was (9.5mm,10.0mm,2.9mm), (4.3mm,4.3mm,2.9mm) and (3.2mm,3.2mm,1.9mm) for the same collimator sizes, respectively, on the Perfexion system. The kV imaging system together with a non-invasive relocatable frame provides accurate target localization (<0.5mm) for cases requiring multiple treatment fractions. Conclusion: Because of the unique dosimetric properties of Co-60 sources

  6. Effect of 60Co γ-rays on polyphenyl methacrylate obtained by γ-ray irradiation

    International Nuclear Information System (INIS)

    Raghunath, S.; Rao, M.H.; Rao, K.N.

    1983-01-01

    Polyphenyl methacrylate of different molecular weights Msub(n) 13000, 34500 and crosslinked polymer prepared by 60 Co γ-irradiation has been irradiated with 60 Co γ-rays at 300 K. G(scission) of the 13000 molecular weight polymer was 15. The crosslinked polymer undergoes both degradation and crosslinking. G(x) value determined for that polymer is approx. 9. The gaseous product consists largely of CO with some CO 2 and H 2 . Hydrocarbon gases were not detected. The yield of H 2 is only to the extent of 2 to 5% of the total gas and it is assumed that majority of scission takes place at the ester linkage. On the basis of the estimation of phenol and benzene, a mechanism for degradation and crosslinking is proposed. (author)

  7. Behavior of the dynamic magnetic susceptibility in ybco bula ceramics irradiated with gamma rays

    International Nuclear Information System (INIS)

    Leyva Fabelo, A.; Bouza Dominguez, J.; Cruz Inclan, Carlos M.

    2001-01-01

    Using measurements of the ac susceptibility, the behavior with the irradiation dose of YBa2Cu3O7- bulk ceramics synthesized by the classic reaction method in solid state, was studied. A Co60 gamma chamber model MPX-G-25M and a Cs137 source were employed as gamma ray sources. The behavior of the beginning temperature of the normal - superconducting state transition with the exposition dose show, independently of the incident gamma energy, a monotonous growth until reaching a threshold dose, after which, observe a fall, more abrupt in the case of the Co60. This behavior can be explained using the model that postulates the ability of the gamma radiation, in certain dose intervals, to stimulate the structural reordering in the oxygen sublattice. When the irradiation process takes place in the Co60 gamma chamber, the behavior of the superconducting volume fraction of the sample characterizes by the initial sharp fall with the dose, followed with an attenuation of the decrement. In the case of Cs137 irradiation, the behavior of the superconducting volume fraction is similar to the behavior of the Ton with the dose

  8. Effect of gamma-ray and electron irradiation on the response of solid-state track detectors

    International Nuclear Information System (INIS)

    Fukuda, Kyue

    1980-01-01

    Specimens of muscovite mica were first exposed to fission fragments and then to various gamma-ray fields from a 60 Co source ranging from 1.9 x 10 3 to 1.6 x 10 4 Mrad dose. The results show that the average etched width of fission-fragment tracks decreases with increasing gamma-ray dose. Shallow pits were observed in etched specimens when the gamma-ray dose exceeded 5 x 10 3 Mrad. Numerous shallow etch pits caused by the gamma-ray irradiation interfered with the observation of fission tracks in the specimens. No shallow etch pits were observed in the specimen annealed for 100 min at 600 0 C before the gamma-ray irradiation. Pre-annealing extends the ''safety limits'' of gamma background below which muscovite mica can be used to observe fission tracks without any gamma-ray interference. Gamma-ray and electron irradiation caused significant increase of the resistance to thermal decomposition of muscovite mica. The resistance increased markedly in the dose range from 5 x 10 3 to 8 x 10 3 Mrad. These phenomena suggest the use of mica to assess radiation doses of gamma rays and electrons up to several thousand megarads. (author)

  9. Gamma-ray relative energy response of Ce: YAG crystal

    International Nuclear Information System (INIS)

    Zhang Jianhua; Zhang Chuanfei; Hu Mengchun; Peng Taiping; Wang Zhentong; Tang Dengpan; Zhao Guangjun

    2010-01-01

    Gamma-ray relative energy response of Ce: YAG crystal, which is important for pulsed γ-ray measurement, was studied in this work.The Ce: YAG crystal, which was developed at Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, was aligned point by point with γ-rays scattered from an industrial 60 Co line source. The γ-ray relative energy response was calculated using the mass attenuation coefficient. The results show that the numerical calculation method of γ-ray relative energy response is reliable, and the experimental method with multi-energy point γ-ray by Compton scattering is also feasible, that can be used for checking up correctness of the numerical calculation results. (authors)

  10. Comparison of W-VC-C composites against Co-60, Se-75 and Sb-125 for gamma radioisotope sources

    Science.gov (United States)

    Demir, Ertugrul; Tugrul, A. Beril; Buyuk, Bulent; Yilmaz, Ozan; Ovecoglu, Lutfi

    2018-02-01

    Tungsten based materials are considered to be the promising materials for nuclear applications due to the good properties. The tungsten composite materials have so many advantages in nuclear technological applications especially fusion reactor systems. In this paper, Tungsten-Vanadium carbide-Graphite (W-VC-C) which include 93% tungsten (W), 6% vanadium carbide (VC) and 1% graphite (C) also which has three different alloying time (6-12-24 hours) were produced by mechanical alloying method. Co-60, Se-75 and Sb-125 gamma radioisotopeswere used as a gamma sources in order to determine behavior of gamma attenuation properties of the composite materials. The experimental results were compared with each other to clarify effects of varying gamma energies on the tungsten based composite materials. The mass attenuation coefficients of the samples were obtained by using XCOM computer code and compared with experimental data. The gamma linear attenuation, the mass attenuation coefficients and half value thickness (HVL) of the samples were evaluated and compared with Co-60, Se-75 and Sb-125 for gamma radioisotopes. Results showed that gamma attenuation coefficients of the samples depend on gamma energies and mechanical alloying time has negatively effect on the gamma shielding properties for the all studied W-VC-C.

  11. Effect of 60Coray irradiation on green coffee beans, 1

    International Nuclear Information System (INIS)

    Tomoda, Goro; Matsuyama, Jun; Hiramoto, Keiko; Izu, Kumie

    1977-01-01

    Green coffee beans were irradiated with 60 Corays at doses of 0, 0.05, 0.5, 5.0 and 10.0 Mrad and the changes of general components in green and roast coffee beans were investigated together with those of the organoleptic properties of roast beans during storage according to the cup testing. In case of Brazil santos beans, irradiation of some 0.05 Mrad 60 Coray gave rather favourable mild flavour and no harmful influence on the quality of coffee, and moreover, would tend to extend the shelf life of roast beans. But influence of irradiation on the quality of coffee differed somewhat between two cultivars, Brazil santos and Colombia. (auth.)

  12. Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier

    Science.gov (United States)

    Israelashvili, I.; Coimbra, A. E. C.; Vartsky, D.; Arazi, L.; Shchemelinin, S.; Caspi, E. N.; Breskin, A.

    2017-09-01

    Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 at cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPM's segmented anode. The localization properties of 60Co gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12± 2 mm and 10± 2 mm (FWHM) were reached with 60Co and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~ 2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.

  13. Efect of Gamma 60Co Irradiation on The Growth, Lipid Content and Fatty Acid Composition of Botryococcus sp. Microalgae

    Directory of Open Access Journals (Sweden)

    Dini Ermavitalini

    2017-04-01

    Full Text Available Botryococcus sp. is one of microalgae species that has a high lipid content as much as 75% of their dry weight. But, lipid production by microalgae is regulated by their environmental condition (pH, light, temperature, nutrition, etc. Mutagenesis induced by Gamma 60Co irradiation can be utilized to alter the Botryococcus sp. genetic to get microalgae mutant strain that can produce a higher lipid content than the wild strain. Botryococcus sp. was irradiated with different doses of gamma ray of 60Co  (0, 2, 4, 6, and 10 Gy,  and the effect  on the growth, lipid content, and fatty acid composition of microalgae were observed. Research design used is random complete (RAL with 95 %  confident level for quantitive analysis based on the biomass and lipid contents. More over fatty acid composition was analyzed by Gas Cromatography-Mass Spectrometry (GC-MS. Results showed that Gamma irradiated gave an effect on growth and lipid content of Botryococcus sp. But between the control treatment (0 Gy with microalgae irradiated dose of 2 Gy, 4 Gy and 6 Gy were not significantly different. Whereas between the control with 10 Gy irradiated was significantly different. The highest biomassa and lipid content are found in 10 Gy irradiated microalgae with 0.833 gram biomass and 41% lipid content. Fatty acid profile of Botryococcus sp. control has 6 fatty acids while 10 Gy irradiated microalgae has 12 fatty acids, with the long-chain fatty acids increased, whereas short-chain fatty acids decreased.

  14. Study on the energy dependence of gamma radiation detectors for 137Cs and 60Co

    International Nuclear Information System (INIS)

    Nonato, Fernanda B.C.; Diniz, Raphael E.; Carvalho, Valdir S.; Vivolo, Vitor; Caldas, Linda V.E.

    2009-01-01

    38 Geiger-Mueller radiation detectors and 9 ionization chambers were calibrated, viewing to study the energy dependence of the monitor response for gamma radiation fields ( 137 Cs and 60 Co). The results were considered satisfactory only for ionization chambers and for some Geiger-Mueller detectors

  15. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  16. The gamma-ray radiation preservation technology for files and books

    International Nuclear Information System (INIS)

    Fan Chengfa; Tian Kaizen; Zhang Yunlu; Gan Saohan; Wang Zhengfu; Xiang Jiafang

    1988-01-01

    In this paper, a radiation appliance using CO-60 Gamma-ray to preserve the files and books is introduced. The lump and transport radiation techniques for processing files and books with this radiation appliance is described. The cost of preserving files and books with this method has been estimated. Comparison of this method with other processing techniques has been taken. (author)

  17. Crosslinking of electrospun poly (VDF-co-HFP) nanofibrous membranes by gamma-ray irradiation

    International Nuclear Information System (INIS)

    Kim, Yun Hye; Lim, Youn Mook; Choi, Jae Hak; An, Sung Jun; Park, Jong Seok; Nho, Young Chang

    2008-01-01

    Poly (VDF-co-HFP)/PEGDMA nanofibrous membranes (NFMs) have been prepared by an electrospinning process. Since electrospun NFMs have a nanoporous structure, they have a potential application for a polymer electrolyte or a separator. Poly (VDF-co-HFP) is a polymer electrolyte binder. In order to improve their mechanical properties, poly (VDF-co-HFP)/PEGDMA NFMs were crosslinked by a gamma-ray irradiation. Then the crosslinked NFMs were characterized through an electrolyte uptake, IR structural analysis, and SEM morphological investigation

  18. Gamma-ray spectral determinations with a portable analyzer

    International Nuclear Information System (INIS)

    Eldridge, J.S.; Oakes, T.W.

    1978-01-01

    A portable sodium iodide spectrometer was used in a variety of field applications. The spectrometer is a battery-operated system complete with a 5 x 5 cm NaI(Tl) detector, 1024 channel memory divisible into four quadrants, special summation and calibration circuits, and a telemeter output for data transmittals. The portable spectrometer has been used to make in situ measurements around a radioactive waste burial ground. Typical spectra of 137 Cs and 60 Co were easily discernible at one such site. Uptake in vegetation near a sealed trench could be observed by placing the NaI(Tl) probe in the foliage. The extent of the spread of low-level contamination of 60 Co was determined in an area that had previously been decontaminated. The unique response of the two 60 Co gamma-rays could be obtained by subtracting the local background response within the computing spectrometer. The ability to perform qualitative identification and to assess hazards in emergency situations has been demonstrated

  19. Multistep carcinogenesis of normal human fibroblasts. Human fibroblasts immortalized by repeated treatment with Co-60 gamma rays were transformed into tumorigenic cells with Ha-ras oncogenes.

    Science.gov (United States)

    Namba, M; Nishitani, K; Fukushima, F; Kimoto, T

    1988-01-01

    Two normal mortal human fibroblast cell strains were transformed into immortal cell lines, SUSM-1 and KMST-6, by treatment with 4-nitroquinoline 1-oxide (4NQO) and Co-60 gamma rays, respectively. These immortalized cell lines showed morphological changes of cells and remarkable chromosome aberrations, but neither of them grew in soft agar or formed tumors in nude mice. The immortal cell line, KMST-6, was then converted into neoplastic cells by treatment with Harvey murine sarcoma virus (Ha-MSV) or the c-Ha-ras oncogene derived from a human lung carcinoma. These neoplastically transformed cells acquired anchorage-independent growth potential and developed tumors when transplanted into nude mice. All the tumors grew progressively without regression until the animals died of tumors. In addition, the tumors were transplantable into other nude mice. Normal human fibroblasts, on the other hand, were not transformed into either immortal or tumorigenic cells by treatment with Ha-MSV or c-Ha-ras alone. Our present data indicate that (1) the chemical carcinogen, 4NQO, or gamma rays worked as an initiator of carcinogenesis in normal human cells, giving rise to immortality, and (2) the ras gene played a role in the progression of the immortally transformed cells to more malignant cells showing anchorage-independent growth and tumorigenicity. In other words, the immortalization process of human cells seems to be a pivotal or rate-limiting step in the carcinogenesis of human cells.

  20. Co60 and Cs137 gamma radiation effects on textured bscco Superconducting fibers

    International Nuclear Information System (INIS)

    Leyva Fabelo, A.; Bouza Dominguez, J.; Cruz Inclan, Crlos M.

    2001-01-01

    Bi2Sr2CaCu2Ox superconducting fibers synthesized by solid state reaction and textured by the method of zonal laser ablation were irradiated with gamma rays of 1.25 MeV and 662 keV and studied the behavior of some of its properties with the exposition dose. The measurements of dynamic magnetic susceptibility were used for the characterization of the samples. It was observed that for the dose of up to 600 kGy in the case of the Co60 and until 500 mGy for the Cs137, the fibers preserve its superconducting intragrain properties. It is an evidence of the high resistance of the material to the radiacional damage. In all the cases were verified that with the increase of the dose the Ton of the transition grows. Two possible mechanisms that play the most important role in this effect are explained in the text. The ac measurements allowed to verified the increasing behavior of the superconducting volume fraction in the sample with the exposition dose

  1. Effect of Gamma Rays on Fast Neutron Registration in CR-39

    CERN Document Server

    Kobzev, A P; El-Halem, A A; Abdul-Ghaphar, U S; Salama, T A

    2002-01-01

    A set of CR-39 plastic detectors with front PE radiator was exposed to Am-Be neutron source, which has an emission rate of 0.86\\cdot 10^{7} sec^{-1}, and the neutron dose equivalent rate 1 m apart from the source is equal to 11 mrem/hr. Another set of samples was irradiated by a neutron dose of 4 rem, then exposed to different gamma-ray doses using ^{60}Co source. It was found that the track density grows with the increase of neutron dose and etching time. It was also found that the bulk etching rate V_{B}, the track diameter and the sensitivity of the CR-39 plastic detector with respect to the neutron irradiation increased with increasing gamma-ray dose in the range 1?10 Mrad. These results show that CR-39 can be considered as a promising fast neutron dosimeter and gamma-ray dosimeter.

  2. Very high-energy gamma rays from gamma-ray bursts.

    Science.gov (United States)

    Chadwick, Paula M

    2007-05-15

    Very high-energy (VHE) gamma-ray astronomy has undergone a transformation in the last few years, with telescopes of unprecedented sensitivity having greatly expanded the source catalogue. Such progress makes the detection of a gamma-ray burst at the highest energies much more likely than previously. This paper describes the facilities currently operating and their chances for detecting gamma-ray bursts, and reviews predictions for VHE gamma-ray emission from gamma-ray bursts. Results to date are summarized.

  3. Scanning of Cargo Containers by Gamma-Ray and Fast Neutron Radiography

    International Nuclear Information System (INIS)

    Yousri, A.M.; Bashter, I.I.; Megahid, M.R.; Osman, A.M.; Kansouh, W.A.; Reda, A.M.

    2011-01-01

    This paper describes the combined systems which were installed and tested to detect contraband smuggled in cargo containers. These combined systems are based on radiographers work by gamma-rays emitted from point source 60 Co with 0.5 Ci activity and neutrons emitted from point isotopic sources of Pu-α-Be as well as 14 MeV neutrons emitted from sealed tube neutron generator. The transmitted gamma ray through the inspected object was measured by gamma detection system with NaI(Tl) detector while the transmitted fast neutron beam was measured by a neutron gamma detection system with stilbene organic scintillator. The later possess the capability of discrimination between between gamma and neutron pulses using a discrimination system based on pulse shape discrimination method. The measured intensities of primary incident and transmitted beams of gamma-rays and fast neutrons were used to construct 2D cross-sectional images of the inspected objects hidden directly within benign materials of the container and for object screened by high dense material to stop object detection by gamma or X-rays. The constructed images for the inspected objects show the good capability and effectiveness of the installed gamma and neutron radiographers to detect illicit materials hidden in air cargo containers and sea containers of med size. They have also indicated that the developed scanning systems possess the ease of mobility and low cost of scanning

  4. Protective effects of vitamin C against gamma-ray induced wholly damage and genetic damage

    International Nuclear Information System (INIS)

    Fu Chunling; Jiang Weiwei; Zhang Ping; Chen Xiang; Zhu Shengtao

    2000-01-01

    Objective: Protective effects of supplemental vitamin C against 60 Co-gamma-ray induced wholly damage and genetic damage was investigated in mice. Method: Mice were divided into normal control group, irradiation control group and vitamin C experimental group 1,2,3 (which were orally given vitamin C 15, 30, 45 mg/kg.bw for 10 successive days respectively prior to gamma-ray irradiation). Micronuclei in the bone marrow polychromatophilic erythrocytes in each group of mice were examined and the 30 day survival rate of mice following whole-body 5.0 Gy γ irradiation were also determined. Results: Supplemental vitamin C prior to gamma-rays irradiation can significantly decrease bone marrow PECMN rate of mice and increase 30 day survival rate and prolong average survival time. The protection factor is 2.09. Conclusion: Vitamin C has potent protective effects against gamma irradiation induced damage in mice. In certain dose range, vitamin C can absolutely suppress the gamma-rays induced genetic damage in vivo

  5. Radiation effects of protons and 60Co γ rays on CMOS operational amplifier

    International Nuclear Information System (INIS)

    Lu Wu; Ren Diyuan; Guo Qi; Yu Xuefeng; Yan Rongliang

    1997-01-01

    Radiation effects of 60 Co γ ray and 4,7 and 30 MeV protons on LF 7650 CMOS operational amplifier were investigated. The damage mechanism of LF7650 was discussed. It is indicated that the mobility reduction of major carrier caused by ionizing and displacement damage is the chief mechanism causing the failure of CMOS operational amplifier irradiated by protons, and that is why the degradation of LF 7650 caused by protons is much more serious than that caused by 60 Co γ ray. In addition, a comparison of proton radiation effects on CMOS operational amplifier and MOSFET showed a significant difference in mechanism

  6. Therapeutic effects of gingerol on hematopoietic and antioxidative damage of 60Co γ-rays irradiated mice

    International Nuclear Information System (INIS)

    Geng Yanyan; Xie Zhenfei; Zhou Yu; Zeng Xianyin

    2012-01-01

    18 female Kunming mice were chosen and randomly divided into three groups, and the therapeutic effects of gingerol on hemopoietic and antioxidative system in liver of 60 Co γ-rays irradiated mice were developed in this study. Control group was given distilled water intragastrically once a day for five days. Mice in the irradiated group and irradiated + gingerol group were both irradiated at 3 Gy of 60 Co γ-rays and were given distilled water and gingerol intragastrically within 30 min after irradiation respectively, once a day for five days. The mice were sacrificed and sampled in 48 hours after intragastric administration. Compared with control group, the relative spleen index and WBC numbers significantly decreased (P 60 Co γ-rays irradiated mice. (authors)

  7. Screening of strains with the high activity and thermostability nattokinase by {sup 60}Co γ-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shuying, Li; Ying, Nie; Huan, Du; Xuanming, Tang [Institute of Agro-products Processing Science and Technology, Chinese Academy of Agricultural Sciences, Beijing (China); Zhonglin, Zhao [College of Sciences, Henan Agricultural University, Zhengzhou (China); Xin, Ma [Agricultural Information Institute, Chinese Academic of Agricultural Sciences, Beijing (China); Yan, Li [School of Food and Biological Engineering, Zhengzhou University of Light Industry, Zhengzhou (China)

    2013-06-15

    In this study, Bacillus natto was irradiated by {sup 60}Co γ-ray, and activity was determined by Casein plate method in order to get high activity and thermostability strains. 60 strains with high activity were obtained through irradiation by 800 Gy {sup 60}Co γ-ray. In this dose, the positive mutation rate was 45%. Then 60 strains was treated by different tempreture and 11 strains showed thermostability at 65℃. (authors)

  8. Screening of strains with the high activity and thermostability nattokinase by "6"0Co γ-ray irradiation

    International Nuclear Information System (INIS)

    Li Shuying; Nie Ying; Du Huan; Tang Xuanming; Zhao Zhonglin; Ma Xin; Li Yan

    2013-01-01

    In this study, Bacillus natto was irradiated by "6"0Co γ-ray, and activity was determined by Casein plate method in order to get high activity and thermostability strains. 60 strains with high activity were obtained through irradiation by 800 Gy "6"0Co γ-ray. In this dose, the positive mutation rate was 45%. Then 60 strains was treated by different tempreture and 11 strains showed thermostability at 65℃. (authors)

  9. Effect of sup 60 Co-gamma radiation on the properties of furs

    Energy Technology Data Exchange (ETDEWEB)

    Raina, R.K.; Wali, B.K. (Regional Research Lab., Srinagar (India)); Wani, A.M. (Nuclear Research Lab., Srinagar (India))

    1990-01-01

    Furs pretanned with various combinations of vegetable tanning agents and retanned with alum have been irradiated with {sup 60}Co {gamma}-radiation in the dose range 5.0-114.0 kGy. The physico-chemical modifications induced by the radiation have been assessed by measuring changes in tensile strength, absorption of water, elongation and shrinkage temperature. For investigations, samples have been taken from the same topographic region of the rabbit furs, belonging to the same age and sex. The results are discussed. (author).

  10. Sensitivity of watermelon variety Bojura to mutant agents 60Co and EMS

    Directory of Open Access Journals (Sweden)

    Nikolay Velkov

    2016-04-01

    Full Text Available A study on the sensitivity of watermelon variety Bojura to mutagenic agents was carried out in 2013-2014. The goal was to establish effective doses for mutagenic treatment of dry seeds with 60Co gamma rays (80, 100, 200, 250, 350 and 450 Gy and swollen seeds with water for 24 hours were treated with ethyl methanesulfonate (EMS at a concentration of 2%. Dominant mutations were not observed in the M1 generation. Morphological changes in 14 of 1395 M2 plants were observed. Phenotypic variations changes were the colour of the seed coat, chlorophyll disorders of cotyledons, leaves, petals, and alterations of the location of the fruit set in the central stem. Visible changes of the morphological characteristics of the fruit were not observed. The doses induced certain morphological changes, however, higher doses or combined gamma rays 60Co and EMS treatments would induce mutations more efficiently. Subsequent experiments are required to obtain mutants with changes that affect flowers and fruits. The results are important for increasing mutation efficiency in watermelon breeding.

  11. Effect of gamma ray on poly(lactic acid)/poly(vinyl acetate-co-vinyl alcohol) blends as biodegradable food packaging films

    International Nuclear Information System (INIS)

    Razavi, Seyed Mohammad; Dadbin, Susan; Frounchi, Masoud

    2014-01-01

    Poly(lactic acid) (PLA)/poly(vinyl acetate-co-vinyl alcohol) [P(VAc-co-VA)] blends as new transparent film packaging materials were prepared at various blend compositions and different vinyl alcohol contents. The blends and pure PLA were irradiated by gamma rays to investigate the extent of changes in the packaging material during gamma ray sterilization process. The miscibility of the blends was dependent on the blend composition and vinyl alcohol content; gamma irradiation had little effect on the extent of miscibility. The glass transition temperature of pure PLA and PLA/P(VAc-co-VA) miscible blends reduced after irradiation. On the other hand in PLA/P(VAc-co-VA) immiscible blends, while the glass transition temperature of the PLA phase decreased; that of the copolymer phase slightly increased. The reduction in the glass transition was about 10 percent for samples irradiated with 50 kGy indicating dominance of chain scission of PLA molecules at high irradiation dose. The latter was verified by drop in mechanical properties of pure PLA after exposing to gamma irradiation at 50 kGy. Blending of PLA with the copolymer P(VAc-co-VA) compensated greatly the adverse effects of irradiation on PLA. The oxygen-barrier property of the blend was superior to the neat PLA and remained almost intact with irradiation. The un-irradiated and irradiated blends had excellent transparency. Gamma ray doses used for sterilization purposes are usually less than 20 kGy. It was shown that gamma irradiation at 20 kGy had no or little adverse effects on PLA/P(VAc-co-VA) blends mechanical and gas barrier properties. - Highlights: • Poly(lactic acid)/poly(vinyl acetate-co-vinyl alcohol) blends were prepared as new packaging film. • The blends are superior to PLA in oxygen gas barrier property. • The blends are suitable for gamma ray sterilization and maintain useful mechanical properties. • The blends are perfectly transparent

  12. The possibility of gamma ray sterilization by using ITU TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Bilge, A.N.; Tugrul, B.; Yavuz, H.

    1988-01-01

    Gamma rays are one of the effective method for sterilization which is preferred for a long time. Generally Co-60 radioisotope sources betatrons or accelerators are used for the sterilization. In this work, it was aimed to find the possibilities of the sterilization by gamma rays obtained in ITU TRIGA Mark-II radial tube. Radiation dosages are measured in the radial tube and several medical products are irradiated. Irradiation is arranged according to the desired dosages. Irradiated sterilized goods (mainly medical products) tested and checked at the Governmental Medical Health Center and results compared with literature. It can be seen that this kind of irradiation is a good tool for sterilization. Unfortunately, because of the stability of the radial tube and impracticality of the system it is rather difficult to compete with industrial system using Co-60 and accelerators. Nevertheless, this type of irradiation is also applicable for the purpose of the sterilization by using ITU TRIGA Mark II. (author)

  13. About cosmic gamma ray lines

    Science.gov (United States)

    Diehl, Roland

    2017-06-01

    Gamma ray lines from cosmic sources convey the action of nuclear reactions in cosmic sites and their impacts on astrophysical objects. Gamma rays at characteristic energies result from nuclear transitions following radioactive decays or high-energy collisions with excitation of nuclei. The gamma-ray line from the annihilation of positrons at 511 keV falls into the same energy window, although of different origin. We present here the concepts of cosmic gamma ray spectrometry and the corresponding instruments and missions, followed by a discussion of recent results and the challenges and open issues for the future. Among the lessons learned are the diffuse radioactive afterglow of massive-star nucleosynthesis in 26Al and 60Fe gamma rays, which is now being exploited towards the cycle of matter driven by massive stars and their supernovae; large interstellar cavities and superbubbles have been recognised to be of key importance here. Also, constraints on the complex processes making stars explode as either thermonuclear or core-collapse supernovae are being illuminated by gamma-ray lines, in this case from shortlived radioactivities from 56Ni and 44Ti decays. In particular, the three-dimensionality and asphericities that have recently been recognised as important are enlightened in different ways through such gamma-ray line spectroscopy. Finally, the distribution of positron annihilation gamma ray emission with its puzzling bulge-dominated intensity disctribution is measured through spatially-resolved spectra, which indicate that annihilation conditions may differ in different parts of our Galaxy. But it is now understood that a variety of sources may feed positrons into the interstellar medium, and their characteristics largely get lost during slowing down and propagation of positrons before annihilation; a recent microquasar flare was caught as an opportunity to see positrons annihilate at a source.

  14. Calibration of intense 60Co gamma ray sources at the Savannah River Plant

    International Nuclear Information System (INIS)

    Bibler, N.E.

    1976-05-01

    Three different dosimeters were used to calibrate Savannah River Plant 60 Co sources having intensities greater than 10 7 rads/hr. These dosimeters are (a) ceric sulfate dissolved in 0.4M H 2 SO 4 , (b) oxalic acid dissolved in water, and (c) a commercially available nylon film containing a radiochromic dye. Response per unit dose to these dosimeters is independent of radiation intensity at 10 4 to 10 11 rads/hr. The dosimeters were calibrated at 6.0 x 10 5 rads/hr with a 60 Co source whose intensity was determined with the standard Fricke dosimeter. For the sources at 10 7 rads/hr or greater, intensities were calculated from slopes of linear plots of dosimeter response versus irradiation time. Individual dose rates varied from 1.0 x 10 7 to 4.6 x 10 7 rads/hr. Each source was calibrated with at least two different dosimeters. Relative standard deviations varied from 2 to 9 percent. A conservative estimate of the uncertainty in the accuracy of these dosimeters is 10 percent. Of the three dosimeters, the nylon film is easiest to use and is therefore recommended for future calibrations

  15. Some gamma radiation (60Co) effects on Chrysomya megacephala (Fabricius, 1794) (Diptira-Calliphoridae)

    International Nuclear Information System (INIS)

    Garcia, C.R.

    1987-03-01

    The effect of different gama radiation ( 60 Co) doses on Chrysomya megcephala (Fabricius) have been studied under laboratory conditions, in the Entomology Section of Centro de Energia Nuclear na Agricultura (CENA-USP), Piracicaba, SP, Brasil. The insects were collected close to sucking animals brooding areas, identified and reared on artificial diet, being kept in a temperature (26 +- 2 0 C) and humidity (66 +- 9%) controlled room, with 12L:12D photopheriod. A Gammabeam type 650 Cobalt-60 gamma irradiation source was used, with 28, 196x10 10 Bq activity at the beginning of the experiment. The pupae were submitted to increasing gamma radiation doses. To determine lethal doses, treatments were carried out at four different ages and to determine the sterilizing doses two-three day pupae were used. It was noted pupae radiosensitivity decreased with age, LD 50 varying from 14 - 513 Gy. The sterilizing dose for males was 40 Gy and for females 30 Gy. During the individuals life cycle, it was noted that there was a decrease in life expectancy (e x o ) of adults when the gamma radiation dose was increased. Treated males were more sensitive than females (Crossed with ''normals''), there occurring a marked reduction in the number of eggs and their viability when the used gamma radiation dose was increased. (author) [pt

  16. Studies of natural and 60Co gamma radio-induced conduction in metaphosphate glasses and silica

    International Nuclear Information System (INIS)

    Mengual Gil, M.A.

    1977-01-01

    A study of natural and 60 Co gamma radio-induced conduction in metaphosphate glasses and silica is presented. The experimental study of natural conduction current in metaphosphate glasses in function of temperature enables to observe two different values of the activation energies in the respective temperature ranges T>223K and T [fr

  17. Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

    Energy Technology Data Exchange (ETDEWEB)

    Ninh, Giang Nguyen; Phongphaeth, Pengvanich, E-mail: phongphaeth.p@chula.ac.th; Nares, Chankow [Nuclear Engineering Department, Faculty of Engineering, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330 (Thailand); Hao, Quang Nguyen [Vietnam Atomic Energy Institute, Ministry of Science and Technology, Hanoi (Viet Nam)

    2016-01-22

    Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

  18. Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

    International Nuclear Information System (INIS)

    Ninh, Giang Nguyen; Phongphaeth, Pengvanich; Nares, Chankow; Hao, Quang Nguyen

    2016-01-01

    Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method

  19. 60Co gamma irradiation effects on the the capacitance and conductance characteristics of Au/PMI/n-Si Schottky diodes

    Science.gov (United States)

    Tuğluoğlu, N.; Karadeniz, S.; Yüksel, Ö. F.; Şafak, H.; Kuş, M.

    2015-08-01

    In this work, the perylene-monoimide/n-Si (100) Schottky structures have been fabricated by spin coating process. We have studied the capacitance-voltage ( C- V) and conductance-voltage ( G- V) characteristics of the Au/perylene-monoimide/n-Si diodes at 500 kHz before and after 60Co γ-ray irradiation. The effects of 60Co γ -ray irradiation on the electrical characteristics of a perylene-monoimide/n-Si Schottky diode have been investigated. A decrease both in the capacitance and conductance has been observed after 60Co γ -ray irradiation. This has been attributed to a decrease in the net ionized dopant concentration that occurred as a result of 60Co γ-ray irradiation. Some contact parameters such as barrier height (Φ B ) interface state density ( N ss ) and series resistance ( R s ) have been calculated from the C- V and G- V characteristics of the diode before and after irradiation. It has been observed that the Φ B and N ss values are decreased after the applied radiation, while the R s value is increased.

  20. A comparison of 4 MeV Proton and Co-60 gamma irradiation induced degradation in the electrical characteristics of N-channel MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Anjum, Arshiya; Vinayakprasanna, N.H.; Pradeep, T.M. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore 570025 (India); Krishna, J.B.M. [IUC-DAE CSR, Kolkota 700098 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India)

    2016-07-15

    N-channel depletion MOSFETs were irradiated with 4 MeV Proton and Co-60 gamma radiation in the dose range of 100 krad(Si) to 100 Mrad(Si). The electrical characteristics of MOSFET such as threshold voltage (V{sub th}), density of interface trapped charges (ΔN{sub it}), density of oxide trapped charges (ΔN{sub ot}), transconductance (g{sub m}), mobility (μ), leakage current (I{sub L}) and drain saturation current (I{sub D} {sub Sat}) were studied as a function of dose. A considerable increase in ΔN{sub it} and ΔN{sub ot} and decrease in V{sub th,}g{sub m}, μ, and I{sub D} {sub Sat} was observed after irradiation. The results of 4 MeV Proton irradiation were compared with that of Co-60 gamma radiation and it is found that the degradation is more for the devices irradiated with 4 MeV Protons when compared with the Co-60 gamma radiation. This indicates that Protons induce more trapped charges in the field oxide region when compared to the gamma radiation.

  1. Effect of gamma ray on poly(lactic acid)/poly(vinyl acetate-co-vinyl alcohol) blends as biodegradable food packaging films

    Science.gov (United States)

    Razavi, Seyed Mohammad; Dadbin, Susan; Frounchi, Masoud

    2014-03-01

    Poly(lactic acid) (PLA)/poly(vinyl acetate-co-vinyl alcohol) [P(VAc-co-VA)] blends as new transparent film packaging materials were prepared at various blend compositions and different vinyl alcohol contents. The blends and pure PLA were irradiated by gamma rays to investigate the extent of changes in the packaging material during gamma ray sterilization process. The miscibility of the blends was dependent on the blend composition and vinyl alcohol content; gamma irradiation had little effect on the extent of miscibility. The glass transition temperature of pure PLA and PLA/P(VAc-co-VA) miscible blends reduced after irradiation. On the other hand in PLA/P(VAc-co-VA) immiscible blends, while the glass transition temperature of the PLA phase decreased; that of the copolymer phase slightly increased. The reduction in the glass transition was about 10 percent for samples irradiated with 50 kGy indicating dominance of chain scission of PLA molecules at high irradiation dose. The latter was verified by drop in mechanical properties of pure PLA after exposing to gamma irradiation at 50 kGy. Blending of PLA with the copolymer P(VAc-co-VA) compensated greatly the adverse effects of irradiation on PLA. The oxygen-barrier property of the blend was superior to the neat PLA and remained almost intact with irradiation. The un-irradiated and irradiated blends had excellent transparency. Gamma ray doses used for sterilization purposes are usually less than 20 kGy. It was shown that gamma irradiation at 20 kGy had no or little adverse effects on PLA/P(VAc-co-VA) blends mechanical and gas barrier properties.

  2. A nonlinear wavelet method for data smoothing of low-level gamma-ray spectra

    International Nuclear Information System (INIS)

    Gang Xiao; Li Deng; Benai Zhang; Jianshi Zhu

    2004-01-01

    A nonlinear wavelet method was designed for smoothing low-level gamma-ray spectra. The spectra of a 60 Co graduated radioactive source and a mixed soil sample were smoothed respectively according to this method and a 5 point smoothing method. The FWHM of 1,332 keV peak of 60 Co source and the absolute activities of 238 U of soil sample were calculated. The results show that the nonlinear wavelet method is better than the traditional method, with less loss of spectral peak and a more complete reduction of statistical fluctuation. (author)

  3. Effect of 60Co γ-rays irradiation on plant regeneration from callus of sea dallisgrass (paspalum vaginatum Sw.)

    International Nuclear Information System (INIS)

    Ye Xiaoqing; She Jianming; Wang Songfeng; Zhang Xu; Liang Liufang; Dong Mingqiang; Wu Yingying

    2010-01-01

    The pellet embryonic calli of Paspalum vagiantum Sw. cv. Adalay were used for 60 Co γ-rays irradiation. In the callus subculture medium with 2, 4-D 2.0 mg /L and BAP 0.05 mg /L, calli were irradiated at the dose rate 1 Gy /min of 60 Co γ-rays. Results showed that the rate of shoot regeneration was from 94% to 85% when calli irradiated with 20 ∼ 50 Gy; the rate of shoot regeneration was from 76% to 30%, and the rate of plant regeneration was from 44.5% to 8.7% between 60 ∼ 80 Gy. By 60 Gy of 60 Co γ-rays irradiation, the rate of shoot regeneration was about 76% in the differentiation medium with BAP 2.0 mg /L, and the relative rate of plant regeneration was 44.5% in the rooting medium with NAA 0.5 mg /L. The result of sequence-related amplified polymorphism (SRAP) markers analysis showed that the specific SRAP markers were associated with the somatic mutants. The mutation technique of 60 Co γ-rays has been established in the somatic cell of Paspalum vaginatum Sw. (authors)

  4. Effect of 60Co γ-rays on PWM and LPS induced lymphocytes

    International Nuclear Information System (INIS)

    Su Liaoyuan; Liu Keliang; Liu Fenju

    1987-01-01

    The relationship between lymphocytes induced by PWM (pokeweed mitogen) and LPS (lipopolysaccharide) was investigated by means of 3 H-TdR incorporation. The study showed that, in vitro, PWM-induced cells were able to promote the stimulating effect of LPS to B lymphocytes. The stimulating effect of PWM-induced cells was obviously weakened after PWM cells being irradiated with γ-rays. When PWM-induced cells and LPS-induced cells were incubated together, with one kind of cells exposed to 60 Co γ-ray, incorporation value of 3 H-TdR became much smaller and the synergetic function disappeared, especially, when PWM-induced cells were irradiated. For patients suffering from carcinoma of nasopharynx, while treated with 60 Co γ-rays, the incorporation value in LPS-induced cells approached normal level, meanwhile, the incorporation value in PEM-induced cells reduced significantly and the stimulating effect of PWM-induced cells on LPS-induced cells became much weaker. The facts described above demonstrated that PWM-induced cells have the function of T-helper cells and play more important role in the synergy than LPS-induced cells

  5. Sensitivity of P-Channel MOSFET to X- and Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    Milić Pejović

    2013-01-01

    Full Text Available Investigation of Al-gate p-channel MOSFETs sensitivity following irradiation using 200 and 280 kV X-ray beams as well as gamma-ray irradiation of 60Co in the dose range from 1 to 5 Gy was performed in this paper. The response followed on the basis of threshold voltage shift and was studied as a function of absorbed dose. It was shown that the most significant change in threshold voltage was in the case of MOSFET irradiation in X-ray fields of 200 kV and when the gate voltage was +5 V. For practical applications in dosimetry, the sensitivity of the investigated MOSFETs was also satisfactory for X-ray tube voltage of 280 kV and for gamma rays. Possible processes in gate oxide caused by radiation and its impact on the response of MOSFETs were also analyzed in this paper.

  6. Chemical changes in the chloroform-paraffin system irradiated by 60Co gamma-rays, 1

    International Nuclear Information System (INIS)

    Yoshino, Tomio; Sakaue, Muneko; Shimizu, Yasuko; Kawamura, Fumio.

    1979-01-01

    It has been reported that the chloroform-paraffin-dye system have excellent sensitivity for radiation as a solid chemical dosimeter or a phantom. However, the chemical changes in the irradiated system are not examined in detail. In the present study, the effect of paraffin on changes in the above system of a liquid state irradiated by 60 Co γ-rays was examined by using various normal paraffin, and the other variable factors on the changes were done. When the chloroform solution and the solution containing 25 per cent of paraffin by volume with 5.0 x 15 -5 mol/liter of Methyl Yellow as a dye were irradiated by 2000 R, G values for the formation of hydrogen chloride in the both solutions were 8.4 and 10.8, respectively, and were little affected by the kind of those, from C 6 (hexane) to C 36 (hexatria-contane). These results suggest that chlorine radical formed by radiolysis of chloroform may react with hydrogen atom from paraffin, thereby increasing the amount of hydrogen chloride. Presence of oxygen increased G value of the chloroform solution from 7.6 to 8.4, but did little that of the solution containing paraffin. (author)

  7. Protective effect of gingerol on leucocyte and bone marrow DNA of 60Co γ-rays irradiated mice

    International Nuclear Information System (INIS)

    Xie Zhenfei; Zhou Yu; Geng Yanyan; Zeng Xianyin

    2012-01-01

    In this article, the effect of gingerol on peripheral leucocyte and bone marrow DNA of 60 Co γ-rays irradiated mice was developed., Twenty-four healthy healthy female Kunming mice were randomly divided into 4 groups: control, gingerol, irradiation and gingerol + irradiation group. Gingerol group and gingerol + irradiation group were given gingerol intragastrically once a day for five days. Irradiation group and gingerol + irradiation group were suffered from 5 Gy 60 Co γ-rays irradiation at the rate of 1.2 Gy/min on the 6 th day. Blood samples, spleens, livers and thigh bones were collected to be measured after 48 h. The results showed that, compared with irradiation group, gingerol + irradiation group had significantly higher spleen index (p 60 Co γ-rays irradiated mice. (authors)

  8. Comparison of the standards of absorbed dose to water of the VNIIFTRI, Russia and the BIPM for {sup 60}Co {gamma} rays

    Energy Technology Data Exchange (ETDEWEB)

    Allisy-Roberts, P.J.; Burns, D.T. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Berlyand, V.; Bregadze, Y.; Korostin, S. [All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements, Moscow (Russian Federation)

    2003-09-15

    A comparison of the standards of absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radio-technical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in {sup 60}Co gamma radiation. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9967 for the calibration factors of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. (authors)

  9. TL detectors for gamma-ray dose measurements in critically accidents

    International Nuclear Information System (INIS)

    Miljanic, S.; Knezevic, Z.; Zorko, B.; Gregori, B.

    2005-01-01

    Full text: Determination of gamma-ray dose in mixed neutron + gamma-ray fields is still a challenging task. Dosemeters used for gamma-ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e. on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosimeter responses to gamma-rays. To reduce all these influences, design of dosemeter holders is of special importance. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma-ray dose determination in mixed fields were examined. Dosemeters were from three different institutions: Ruder Boscovic Institute (RBI), Croatia, Jozef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. At that exercise three accidental scenarios were reproduced: bare reactor, free evolution; lead shielded reactor, steady state; and lead shielded reactor, free evolution. In each irradiation dosemeters were exposed placed on the front of phantom and 'free-in-air'. Also, dosemeters were irradiated in a pure gamma ray field of 60 Co source. Following types of TLDs were used: 7 LiF (TLD-700), CaF 2 :Mn and AI 2 O 3 :Mg,Y - all from RBI; CaF 2 :Mn from JSI and 7 LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the mean participants' values. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed. (author)

  10. Gamma ray generator

    Science.gov (United States)

    Firestone, Richard B; Reijonen, Jani

    2014-05-27

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  11. Molecular level analyses of mechanical properties of PTFE sterilized by Co-60 γ-ray irradiation for clinical use

    Science.gov (United States)

    Furuta, Masakazu; Matsugaki, Aira; Nakano, Takayoshi; Hirata, Isao; Kato, Koichi; Oda, Takashi; Sato, Mamoru; Okazaki, Masayuki

    2017-10-01

    Recently, Co-60 gamma-ray irradiation has become markedly popular for the sterilization of biomedical materials, including expanded PTFE. However, its effect on the properties of PTFE has not been thoroughly examined. In this study, changes in the properties of PTFE before and after irradiation were analyzed physicochemically and discussed crystallographically. The tensile breaking strengths of PTFE decreased markedly on irradiation at 1 kGy, and were maintained at almost one fourth of the original value (44.3±2.5 N/mm2) ranging from 5 to 100 kGy. XPS analysis indicated that the atomic concentrations of carbon (C) and fluorine (F) of PTFE were not different among samples irradiated at various dosages. Raman spectra of PTFE showed a slight increase of the absorption peak intensity at 735 cm-1 in an irradiation dosage-dependent manner. X-ray diffraction showed that the crystal size of PTFE (56.7±1.0 nm) became smaller after radiation at 100 kGy (48.5±0.6 nm). These results are consistent with the above results of Raman analysis. It is suggested that the observed changes in the mechanical properties of PTFE may be due to nano-scale C-C bond scission by gamma ray irradiation, and not due to the formation of micro-scale cracks.

  12. Induced mitotic gynogenesis in common carp (Cyprinus carpio L.), optimizing irradiation dose of X- and gamma-ray

    International Nuclear Information System (INIS)

    Yousefian, M.; Amirinia, C.; Bercsenyi, M.; Horvath, L.

    1997-01-01

    Mitotic gynogenesis was induced in common carp, Cyprinus carpio L., in hatchery and laboratory conditions, using 60Co gamma-ray and X-ray for inactivation of sperm DNA and a subsequent heat shock for inducing endomitosis. The parameter examined was the dose of irradiation in the range of 70-140 Krad. Carp spermatozoa irradiated by 70-100 Krad doses showed higher motility and fertilization ability than the ones irradiated by 110-140 Krad. Sperm treated with doses of 70-90 Krad showed the same fertility rate, but lower survival rate at embryo stage compared with 100 Krad. The shock temperature and duration applied in these experiments for restoration of diploidy level were 40 degrees C plus/minus 0.1 and 2 min., respectively. The highest frequency of mitotic gynogenetic larvae was achieved by 100 Krad 60Co gamma ray at 34 min. after fertilization, - up to 12.2 percent (at 23 degrees C incubating temperature)

  13. Crystal glass used for X ray and gamma radiation shielding - Part two

    International Nuclear Information System (INIS)

    Antonio Filho, Joao

    2007-01-01

    Crystal glass has been widely used as shielding material in gamma radiation sources as well as x-ray generating equipment to replace the plumbiferous glass, in order to minimize exposure to individuals. However, properties of the radiation attenuation of crystal glass commercially available in Brazil, for the different types of energy are not known. For this reason, this work was carried out aiming to determine the radiation attenuation, transmission curves and Half Value Layer. In this work, ten plates of crystal glass, with dimensions of 20 cm x 20 cm and range of thicknesses from 0.5 to 2.0 cm, were used. The plates were X-ray irradiated with potential constants of 60, 80, 110, 150 kV and gamma radiation of 60 Co. Analysis in the properties of the 60 Co radiation attenuation of barite plaster and barite concrete commercially available in Brazil were also carried out. The curves of attenuation and of transmission were obtained for crystal glass, barite plaster and barite concrete (mGy/mA.min) at 1 meter as a function of thickness. The thickness equivalent of a half value layer and deci value layer of crystal glass for all types of radiation and energies studied was also determined. (author)

  14. Specialized software utilities for gamma ray spectrometry. Final report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2002-03-01

    A Co-ordinated Research Project (CRP) on Software Utilities for Gamma Ray Spectrometry was initiated by the International Atomic Energy Agency in 1996 for a three year period. In the CRP several basic applications of nuclear data handling were assayed which also dealt with the development of PC computer codes for various spectrometric purposes. The CRP produced several software packages: for the analysis of low level NaI spectra; user controlled analysis of gamma ray spectra from HPGe detectors; a set of routines for the definition of the detector resolution function and for the unfolding of experimental annihilation spectra; a program for the generation of gamma ray libraries for specific applications; a program to calculate true coincidence corrections; a program to calculate full-energy peak efficiency calibration curve for homogenous cylindrical sample geometries including self-attenuation correction; and a program for the library driven analysis of gamma ray spectra and for the quantification of radionuclide content in samples. In addition, the CRP addressed problems of the analysis of naturally occurring radioactive soil material gamma ray spectra, questions of quality assurance and quality control in gamma ray spectrometry, and verification of the expert system SHAMAN for the analysis of air filter spectra obtained within the framework of the Comprehensive Nuclear Test Ban Treaty. This TECDOC contains 10 presentations delivered at the meeting with the description of the software developed. Each of the papers has been indexed separately

  15. 60Co gamma radiation effect on AlGaN//AlN/GaN HEMT devices

    International Nuclear Information System (INIS)

    Wang Yanping; Luo Yinhong; Wang Wei; Zhang Keying; Guo Hongxia; Guo Xiaoqiang; Wang Yuanming

    2013-01-01

    The testing techniques and experimental methods of the 60 Co gamma irradiation effect on AlGaN/AlN/GaN high electron mobility transistors (HEMTs) are established. The degradation of the electrical properties of the device under the actual radiation environment are analyzed theoretically, and studies of the total dose effects of gamma radiation on AlGaN/AlN/GaN HEMTs at three different radiation bias conditions are carried out. The degradation patterns of the main parameters of the AlGaN/AlN/GaN HEMTs at different doses are then investigated, and the device parameters that were sensitive to the gamma radiation induced damage and the total dose level induced device damage are obtained. (authors)

  16. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  17. Constraints on the galactic distribution of cosmic rays from the COS-B gamma-ray data

    International Nuclear Information System (INIS)

    1985-08-01

    The velocity information of the HI and CO observations is used as a distance indicator to ascertain the spatial distribution of the interstellar gas. Using this distance information, the galacto-centric distribution of the gamma-ray emissivity (the production rate per H atom) is determined for three gamma-ray energy ranges from a correlation study of the gamma-ray intensity maps and the gas-tracer maps for selected galacto-centric distance intervals, taking into account the expected IC contribution and pointlike gamma-ray sources. On the assumption that unresolved gamma-ray point sources do not contribute significantly to the observed gamma-ray emission, the gamma-ray emissivity is proportional to the Cosmic ray density and, more specifically, the energy dependence can be used to study separately the distribution of Cosmic ray electrons and nuclei: whereas the emission for the 300 MeV - 5 GeV range is dominated by π 0 -decay, the 70 MeV - 150 MeV range has a large electron bremsstrahlung contribution

  18. Investigations on Pasteurization of Cold Marinades by {sup 60}Co Gamma Rays; Recherches sur la Pasteurisation a Froid De Marinades par les Rayons Gamma du {sup 60}Co; Issledovaniya pasterizatsii kholodnykh marinadov gamma-luchami; Investigaciones Sobre la Pasteurizacion de Escabeches Frios por Irradiacion Gamma con {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Schoenborn, W.; Kinkel, R J.; Hafferl, W. [Battelle Institut e.V., Frankfurt/Main, Federal Republic of Germany (Germany)

    1966-11-15

    Marinated herring fillets are a fish product matured under the action of acetic acid and salt and marketed in a spiced brine containing about 3% salt and acetic acid (pH 4). Since the usual addition of the preservative hexamethylene-tetramine has been restricted to a limited period of time by the new German food law, investigations were made on pasteurization by means of ionizing rays, as a new method of preservation without the addition of other preservatives. Decay of this food product was caused by heterofermentative lactic-acid bacteria, which decarboxy- lated the amino acids set free from the protein; the decay was a result of carbon dioxide bombardment. The marinades were packed into flat tins holding about 125 g, and exposed to {sup 60}Co gamma rays from an under-water source, while being cooled. The shelf life of the tinned marinades was extended by the irradiation. The period up to bombardment at 15 Degree-Sign C was three times as long as usual in cases of irradiation with 155 krad. The critical number of 1 million germs per ml at 15 Degree-Sign C was also reached after a period three times as long as usual upon irradiation with 160 krad. The LD{sub 99} of three isolated strains of lactic-acid bacteria irradiated in a salt-peptone solution was 113, 165 and 144 krad, respectively. Since at 15 Degree-Sign C the growth of the germs is retarded, while at 20 Degree-Sign C it is practically unrestrained, the period of durability at a storage temperature of 18 Degree-Sign C could only be doubled by irradiation with 280 krad. The organoleptic tests were based on preference analyses by means of the nine-step Hedonic scale, and on difference tests (triangle test) and were performed by a paneli At 70 krad the taste is still acceptable at 140 krad there is a distinct taste of rays and at 280 krad the taste is disagreeable. A distinct improvement in taste is achieved by irradiation at low temperatures (-30 Degree-Sign C) and by the addition of ascorbic acid, sorbitol

  19. Hypodontia in the beagle after perinatal whole-body 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Lee, A.C.; Angleton, G.M.; Benjamin, S.A.

    1989-01-01

    As part of a long-term study to evaluate health effects of pre- and postnatal irradiation, dental development was examined. Beagles were irradiated in utero at 8, 28, or 55 days postcoitus or postnatally at 2, 70, or 365 days postpartum. Whole-body 60 Co gamma radiation doses ranged from 0 to 3.8 Gy. There was an age-dependent dose-related increase in premolar hypodontia for animals irradiated at 55 days postcoitus or 2 days postpartum with doses of 0.83 Gy or higher and for those irradiated at 28 days postcoitus with 1.2 Gy or higher

  20. Effect of 60Co-gamma radiation on the binding properties in furs

    International Nuclear Information System (INIS)

    Raina, R.K.

    1992-01-01

    New Zealand white rabbit pelts were pickled by the usual procedure and were tanned with basic aluminium sulphate, basic chromium sulphate and their combinations. Tanned furs were irradiated with 60 Co-gamma radiations in the dose range of 5.0-114.0 kGy. The effect of radiation on the binding properties of various added substances like mineral tannins, fats, moisture and shrinkage temperature has been assessed by their comparison with the control samples. The results of these investigations show that radiation on furs causes detannage, increases the moisture and bound fat content and decreases the shrinkage temperature of the furs. (author)

  1. Measurement of concentrations of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Akira; Kawasaki, Katsuya; Kikuchi, Masamitsu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Harada, Yasunori

    1997-07-01

    Measurement has been made to study distributions of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility. Core boring was carried out at seven positions to take samples from the concrete shield, and {gamma}-ray counting rates and {gamma}-ray spectra of these samples were measured with a NaI(Tl) detector and a Ge semiconductor detector, respectively. The following radionuclides were detected in the concrete samples: {sup 60}Co, {sup 134}Cs, {sup 152}Eu and {sup 154}Eu generated through thermal neutron capture reaction, and {sup 22}Na and {sup 54}Mn generated through nuclear reactions by bremsstrahlung and fast neutrons. The relation between the distributions of {gamma}-ray emitters, as a function of the depth of concrete, and the positions of core boring is discussed. (author)

  2. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.; Lee, Y.J.

    1984-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-power detectors, a new type of self-powered detectors was designed and fabricated by the author,and experiments have carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the total signal is negligibly small. The results are 1)sensitivity is depended primarily on the materials of the insulator, 2)output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author)

  3. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.

    1983-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-powered detectors, a new type of self-powered detectors was designed and fabricated by the author, and experiments have been carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the totel signal is negligibly small. The results are 1) sensitivity is depended primarily on the materials of the insulator, 2) output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author) πT

  4. Decontamination of salmonella from the coastal fish meals by 60Co γ ray irradiation

    International Nuclear Information System (INIS)

    Saheki, Kazuaki; Konno, Kenjiro; Sato, Takae; Kawabata, Toshiharu.

    1988-01-01

    The decontamination fo salmonellae from fish meal samples by irradiation which 60 Co γ ray was examined. Sixteen strains of Salmonella were used. A composite fish meal sample was prepared by mixing with different coastal meals, and after radiation sterilization at a dose of 20 kGy 60 Co γ ray, which was employed as the salmonella-free meal sample. D 10 values of test strains determined in buffered saline were found to range from 0.08 to 0.36 kGy, and inactivation factors at a dose of 1 kGy ranged from 10 2.8 to 10 13 . D 10 values of test strains determined in the salmonella-free meal sample ranged from 0.59 to 1.64 kGy, and the inactivation factors at a dose of 10 kGy were found to range from 10 6.1 to 10 17 . Interestingly the D 10 values of salmonellae determined in fish meal samples were 10 times as much compared with those determined in buffered saline. From the commercial aspects of coastal fish meal production, destruction of salmonellae in fish meals by 60 Co γ ray irradiation was found to be much more practical than other methods such as dry heating and ethylene oxide fumigation. (author)

  5. Effects if 60Co γ rays radiation on seed vigor and young seedling growth of phyllostachys edulis

    International Nuclear Information System (INIS)

    Cai Chunju; Gao Jian; Mu Shaohua

    2007-01-01

    The dry seeds of Phyllostachys edulis were irradiated by different doses of 60 Co γ rays, the effects of the radiation on seed vigor and seedling growth characters were investigated by four testing methods, i.e. germination testing indoor, electrical conductivity, TTC vigor testing and growth classification of saddling. Results showed that the germination process and germination rate could be accelerated by doses of 60 Co γ rays (≤100 Gy), and higher doses of 60 Co γ rays (>100 Gy) could obviously inhibit the germination process and reduce seed vigor, while induce seed embryo broken, cell division, growth restrained, the height of young seedling and length of root decreasing. The inhibition effects were significantly increased with radiation dose increase. The optimal range of radiation dose for radiation breeding of Phyllostachys edulis dry seeds was 100 to 175 Gy. Linear relationships were existed in electrical conductivity after dipping in water for 24h in germination rate (G), germination index (GI), vigor index (VI), height of seedlings and length of root. EC after 24h and height of seedlings were chosen to test the change of seeds vigor and the effect of the radiation of 60 Co γ rays on Phyllostachys edulis. (authors)

  6. Deep underground measurements of 60Co in steel exposed to the Hiroshima atomic bomb explosion.

    Science.gov (United States)

    Hult, Mikael; Gasparro, Joël; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-01-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure 60Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure 60Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations.

  7. Deep underground measurements of 60Co in steel exposed to the Hiroshima atomic bomb explosion

    International Nuclear Information System (INIS)

    Hult, Mikael; Gasparro, J.Joeel; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-01-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure 60 Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure 60 Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations

  8. Observations of the highest energy gamma-rays from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dingus, Brenda L.

    2001-01-01

    EGRET has extended the highest energy observations of gamma-ray bursts to GeV gamma rays. Such high energies imply the fireball that is radiating the gamma-rays has a bulk Lorentz factor of several hundred. However, EGRET only detected a few gamma-ray bursts. GLAST will likely detect several hundred bursts and may extend the maximum energy to a few 100 GeV. Meanwhile new ground based detectors with sensitivity to gamma-ray bursts are beginning operation, and one recently reported evidence for TeV emission from a burst

  9. Gamma ray irradiation characteristics of SM fibers

    International Nuclear Information System (INIS)

    Ito, Ryuichi; Okano, Hiroaki; Hashiba, Keichi; Nakai, Hisanori

    1987-01-01

    1.3 μm range single mode (SM) optical fibers have been used for wide application of mainly long distance communication. At present, in order to realize the larger capacity and longer distance between relay points, the development of 1.5 μm range SM fibers of low dispersion and small loss has been actively promoted. As for the radiation withstanding property of SM fibers, report is scarce. The authors reported on the gamma ray irradiation characteristics of 1.3 μm range SM fibers, but since 1.5 μm range SM fibers are designed with the different structure from that of 1.3 μm fibers, it is necessary to evaluate from new viewpoint. In this report, mainly on the structure having triangular distribution, the effect that the manufacturing condition and the structural defects of glass exert on the gamma ray irradiation characteristics is described. The specimens were mainly dispersion shift type fibers (DSF), and for comparison, single window, double window and 1.3 μm SM fibers were examined. Co-60 gamma ray was irradiated, and the optical loss and electron spin resonance were measured. By low temperature and low speed drawing, the good result in the optical loss was obtained. The presence of oxygen at the time of sintering materials had no effect. The dependence of the ESR on the drawing condition was not very remarkable. (Kako, I.)

  10. Half-lives of isomeric levels of 107mAg, 109mAg and 103mRh photoactivated by 60Co γ-ray irradiation

    International Nuclear Information System (INIS)

    Yoshida, Eiji; Kobayashi, Takashige; Kojima, Yasuaki; Shizuma, Kiyoshi

    2000-01-01

    Photoactivation by γ-rays from 60 Co of 10 kCi has been performed for isomers of 107m Ag, 109m Ag and 103m Rh and half-lives of these isomers were determined. Gamma-rays emitted from 107m Ag and 109m Ag were measured with a low-background Ge detector and internal conversion electrons from 103m Rh were measured with a 2π gas flow counter. The half-lives obtained are: 107m Ag: 44.5±0.8 s, 109m Ag: 38.0±1.2 s and 103m Rh: 54.8±3.8 min. The results are in agreement with previous values obtained by different excitation methods

  11. Contribution to the study of the behaviour of silicon planar transistors exposed to the {sup 60}Co {gamma} rays; Contribution a l'etude du comportement des transistors silicium a structure plane soumis aux rayons {gamma} du {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Le Ber, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-05-15

    This report gives an account of studies carried out on bipolar silicon planar transistors irradiated by {sup 60}Co {gamma} rays. The author describes the interactions on the matter of the different types of particles and he gives a brief bibliographical recall of foreign studies. The technological structure of the planar transistors is then described in order to help the understanding of the phenomena, general comments are made about the choice of measured parameters and on the statistical interpretation of results. An automatic instrument for the measurement of the gain is described and the reproducibility of the results is stated The complexity of the problem and the difficulty to predict the behaviour of the semiconductors components are clearly shown. It is stated that the observed dispersions depend on: - the electrical bias during irradiation - the injection level in the emitter-base junction during the measurement - the manufacturer for a given type - the instantaneous dose rate - the geometry used The problem is then examined from the reliability point of view and methods are given to evaluate the reliability for a given dose - 'Worst case' method - moment method - Monte Carlo method. (author) [French] Ce rapport rend compte du travail effectue sur les transistors bipolaires au silicium irradies au rayons {gamma} du cobalt 60. On passe en revue les mecanismes d'interaction des differents rayonnements avec la matiere et on fait un bref rappel bibliographique des etudes effectuees a l'etranger. On decrit ensuite la structure technologique du transistor pour aider a la comprehension des phenomenes, puis on donne des generalites sur le choix des parametres mesures et l'interpretation statistique des resultats. On decrit l'ensemble du systeme de mesure de gain et on s'attache a montrer la reproductibilite des mesures. Les resultats experimentaux mentionnes etablissent clairement la complexite du probleme et la difficulte qu'il y a de faire des previsions. On

  12. Developments in gamma-ray spectrometry: systems, software, and methods-II. 3. Low-Energy Gamma-Ray Spectrometry Using a Compton-Suppressed Telescope Detector

    International Nuclear Information System (INIS)

    Sigg, R.A.; DiPrete, D.P.

    2001-01-01

    the new detector system has an ambient background count rate in the 30- to 600-keV region that is only 1/20 that of an earlier large area, low-energy photon spectrometer. For low-activity samples, whose counting backgrounds are dominated by natural background, minimum detectable activities are improved by a factor of ∼4. This improvement is attributable to a combination of factors including fabrication from low-background materials, cryostat geometry, passive and active shielding, and a lower ambient background location. Measurements using the newer system with and without gating reveal that most of this background reduction can be credited to active vetoing provided by guard detectors. Further improvements are anticipated as a nitrogen purge capability (to exclude radon from the shield) is implemented. An earlier paper (Ref. 2) described radiochemical separations and counting for 129 I, a long-lived fission product of interest at SRS because of the site's processing of spent nuclear fuels. While such radiochemical separations are necessary for many low-level analyses of 129 I, some low-density samples contain sufficient activity to allow 129 I analysis without chemistry if Compton-scattered interferences from other radionuclides are removed electronically. Tests on such a sample show that the sodium iodide and rear germanium anti-coincident guard detectors suppress the Compton continuum in the region near 129 I's 39-keV peak by a factor of ∼4. Interfering activities in the sample included 60 Co, 152 Eu, 154 Eu, and 241 Am. The Compton-suppression ratio is a function of gamma-ray energy; it improves as gamma ray energy increases until the best suppression (a factor of ∼10 for the sample discussed) is achieved at ∼1 MeV. (authors)

  13. Gamma ray irradiation induced optical band gap variations in silica sol-gel doped sucrose

    International Nuclear Information System (INIS)

    Marzouki, F.; Farah, K.; Hamzaoui, A.H; Ben Ouada, H

    2015-01-01

    The silica xerogels doped sucrose was prepared via sol-gel process and exposed at room temperature to different doses of high energy ("6"0Co) gamma irradiation. Changes in the UV-visible and FTIR spectra of pristine and irradiated xerogels with varying of gamma doses rays show variation in the gap energy. It was found that energy gap of the investigated silica xerogels decreases with increasing the gamma irradiation doses. Thereby the irradiated samples reveal behaviour changes, from an insulator (Eg ∼5,8 eV) towards a semiconductor with (Eg ∼ 3.5 eV).

  14. 60Co-labeling in 59Co(n,γ)60Co reaction and γ-ray irradiation of [Co(dien)2]3+ and [Co(en)3]3+ in crystals and/or in polyvinyl alcohol

    International Nuclear Information System (INIS)

    Sasaki, K.; Iiyoshi, N.; Watanabe, J.; Yamatera, H.

    1982-01-01

    Three isomers (sym-fac, unsym-fac, and mer forms) of [Co(dien) 2 ]Cl 3 were irradiated in a reactor in the form of crystals and in amorphous solids, where the ions were dissolved in polyvinyl alcohol (PVA) or adsorbed on an SP-Sephadex ion exchanger. The distribution of produced 60 Co among the isomers of the Co(III) complex and the Co(II) species was determined. The preferential labeling on the parent isomer was observed in crystals but not in PVA. In the Sephadex, no marked labeling occurred. For comparison with reactor-irradiated samples, mixed solutions of [Co(dien) 2 ]Cl 3 and 60 Co-labeled cobalt (II) chloride dissolved in PVA films ([Co(III)]/[Co(II)] = 2 - 3) were irradiated by γ-rays. Significant labeling was observed after the irradiation. Comparison of the results from the above experiments showed that the labeling was enhanced by radiation chemical reactions, and that the preferential labeling on the parent isomer of crystal samples resulted from the stiffness of the crystal matrix. (orig.)

  15. Effects of CO-60 gamma radiation on the embryonary development of Biomphalaria Glabrata (Say, 1818)

    International Nuclear Information System (INIS)

    Okazaki, K.

    1988-01-01

    Some aspects of the effects of the ionizing radiation on the embryo and on the genetical material of Biomphalaria glabrata (Mollusca: Gastropoda) are presented. The embryos weresubmitted at various stages of development to doses of 5,10,15,20 and 25 Gy of Co-60 gamma radiation. As a criteia of evaluation of the embryos radiosensitivity, four biological parameters were used: mortality, malformation, hatching and chromossomal aberrations. (M.A.C.) [pt

  16. Influence of 60Co gamma radiation on Zabrotes subfasciatus (Bohemann, 1833) (Coleoptera, Curculionidae) and beams Phaseolus vulgaris

    International Nuclear Information System (INIS)

    Moraes Rego, A.F. de; Rodrigues, Z.A.; Oliveira, M.L. de; Santana, M.D.

    1986-01-01

    Influence of gamma radiation on Zabrotes subfasciatus (Boh, 1833) (Coleoptera Bruchidae) and the beans Phaseolus vulgaris (L.). The effects of 60 CO gamma radiation, 50 Gy, on both Phaseolus vulgaris (L.) seedbeans and adults of Zabrotes subfasciatus were studied using the no free choise method. Radiation decreased insect fertility hence insect population and it damage loss of weight and germination of seedbeans. However, radiation resulted in abnamal seedlings, showing various degrees of morphological malformation, although there was no effect on germination rates or seedling vigor. (Author) [pt

  17. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  18. Grafting study of polysulfone polymeric membranes by gamma ray irradiation

    International Nuclear Information System (INIS)

    Furtado Filho, Acacio A.M.; Gomes, Ailton de S.

    2011-01-01

    Radiation-induced grafting of styrene poli sulfone films were investigated by simultaneous method in solution using gamma-ray from a radio nuclide 60 Co source. The gamma-ray energy of high intensity induced breaking of chemical bonds leading to free radical formation. The radical start a conventional polymerization sequence comparable with that obtained with a chemical catalyst acting as initiator. The effects of grafting conditions such as irradiation total dose, dose rate and addition of cross linking agent, were studied by means of morphology analysis, thermal degradation and crystallinity. After the grafting reaction, the membranes were submitted to an exhaustive extraction with solvent to remove the polystyrene homopolymer formed. The degree of grafting (DOG) was analyzed by percentage of weight increase. As a result, the reaction always follows the same pattern: DOG increases rapidly initially whilst propagation is the main reaction, then more slowly as termination becomes more frequent. (author)

  19. Deep underground measurements of {sup 60}Co in steel exposed to the Hiroshima atomic bomb explosion

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Mikael E-mail: mikael.hult@cec.eu.int; Gasparro, J.Joeel; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-09-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure {sup 60}Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure {sup 60}Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations.

  20. Studies of radiation gamma effects of 60 Co on fecundity, fertility and survival of Biomphalaria straminea (Dunker, 1848)

    International Nuclear Information System (INIS)

    Albuquerque Melo, Ana M.M. de; Motta, Mauricy A. da

    1997-01-01

    The effects of gamma 60 Co radiation on fecundity, fertility and survival of Biomphalaria straminea was carried out with these mollusks kept in totality reproductive isolation and grouped, for their possible utilization in the study of radiation effect in biological system. Biomphalaria straminea species are disseminated in Brazil, specially in Northeast region. The snails were exposed to the following doses of gamma radiation: 2.5; 5.0; 7.5; 10; 15; 20; 25; 30; 35; 40; 45; 55; 60; 80; 160; 320; and 640 gy source was a Gamma Cell Co model RL (rate dose = 0,31 Gy/min). The fecundity was observed through the count of the spawing abd eggs number/snail/day; the fecundity and fertility when the radiation dose increased; it was evidenced that the grouped mollusks presented a better performance in respectivity when compared with the isolated ones. After the statistical analysis was observed that fercundity and fertility were closely related. The survival, presented higher levels of resistence in isolated mollusks than in grouped ones. The DL50/30 obtained for the isolated mollusks submitted the radiation was about 90 Gy and for the grouped ones 70 Gy. (author). 29 refs., 3 figs., 2 tabs

  1. Operating experience with gamma ray irradiators

    International Nuclear Information System (INIS)

    Fraser, F.M.; Ouwerkerk, T.

    1980-01-01

    The experience of Atomic Energy of Canada, Limited (AECL) with radioisotopes dates back to the mid-1940s when radium was marketed for medical purposes. Cobalt-60 came on the scene in 1949 and within a few years a thriving business in cancer teletherapy machines and research irradiators was developed. AECL's first full-scale cobalt-60 gamma ray sterilizer for medical products was installed in 1964. AECL now has over 50 plants and 30 million curies in service around the world. Sixteen years of design experience in cobalt-60 sources, radiation shielding, safety interlock systems, and source pass mechanisms have made gamma irradiators safe, reliable, and easy to operate. This proven technology is being applied in promising new fields such as sludge treatment and food preservation. Cesium-137 is expected to be extensively utilized as the gamma radiation source for these applications

  2. Gamma ray energy spectrum of a buried radioactive source

    Energy Technology Data Exchange (ETDEWEB)

    Massey, N B

    1957-07-01

    Because of current attempts to utilize airborne gamma-ray scintillation spectrometers as a means of detecting and identifying buried radioactive mineral deposits, it has become important to study the effects of multiple scattering on the gamma-ray energy spectrum of a source buried in a semi-infinite medium. A series of ten experiments was made. First a scintillation detector was located in air at a fixed distance above a 250 microcurie cobalt-60 source suspended in a large tank. The level of water was raised from 25 cm below the source to 50 cm above, and the gamma-ray energy spectrum was observed. It was found that the high energy portion of the cobalt-60 spectrum remained identifiable even when the source was submerged more than five half-lengths. Further, the ratio of the counting rate of the total incident gamma radiation to the counting rate of the primary 1.33 MeV radiation was found to be very nearly linearly proportional to the depth of water cover. This leads to an empirical method for determining the depth of burial of a cobalt-60 point source. (author)

  3. Thermoluminescence of simulated interstellar matter after gamma-ray irradiation. Forsterite, enstatite and carbonates

    Science.gov (United States)

    Koike, K.; Nakagawa, M.; Koike, C.; Okada, M.; Chihara, H.

    2002-08-01

    Interstellar matter is known to be strongly irradiated by cosmic radiation and several types of cosmic ray particles. Simulated interstellar matter, such as synthesized forsterite (Mg2SiO4), enstatite (MgSiO3) and magnesite (MgCO3), has been irradiated with 60Co gamma-rays in liquid nitrogen, and also irradiated with fast neutrons at 10 K and 70 K by making use of the low-temperature irradiation facility of the Kyoto University Reactor (KUR-LTL. Maximum fast neutron dose is 1017nf /cm2). After irradiation, samples are stored in liquid nitrogen for several months to allow the decay of induced radioactivity. We measured the luminescence spectra of the gamma ray irradiated samples during warming to 370 K using a spectrophotometer. For the forsterite and magnesite, the spectra exhibit a rather intense peak at about 645-655 nm and 660 nm respectively, whereas luminescence scarcely appeared in the natural olivine sample. The spectra of forsterite is very similar to the ERE of the Red Rectangle.

  4. Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.

  5. Effects of gamma radiation from 60Co on dilute aqueous solutions of Linear Alkyl Sulfonate Surfactants and other organic pollutants

    International Nuclear Information System (INIS)

    Rohrer, D.M.

    1975-01-01

    This study is the result of research findings and operational experiences gained by the author in over four years of work associated with the use of 60 Co for the treatment of waste-water. The effects of 60 Co are discussed with regard to radiochemical destruction of specific organic pollutant species. The study deals specifically with the effects of gamma radiation from a 30,000 Ci 60 Co source upon aqueous solutions of Linear Alkyl Sulfonate Surfactants. The new Linear Alkyl Sulfonate (LAS) Surfactants, the major surfactant produced in the United States of America since June 1965, was developed to replace the old Alkyl Benzene Sulfonate (ABS) Surfactants. The reason for the removal of Alkyl Benzene Sulfonate Surfactants was their extreme environmental stability and the associated appearance of foam in waste-water treatment plants and receiving streams. Although the Linear Alkyl Sulfonate Surfactants are considered 'bio-degradable', the time required for 'bio-degradation' is impractical within the present environmental guidelines. This led to research into alternate techniques of treatment for the destruction of Linear Alkyl Sulfonate Surfactants. Consideration is also given to similar effects of gamma radiation upon pesticides and to the practical aspects of the use of gamma radiation for the treatment of waste-water. Included are discussions of the general experimental procedures used, the sources and their calibration, and sampling techniques to ensure the accuracy of the data. (author)

  6. Effect of [sup 60]Co-gamma radiation on the binding properties in furs

    Energy Technology Data Exchange (ETDEWEB)

    Raina, R K [Regional Research Lab., Srinagar (India)

    1992-09-01

    New Zealand white rabbit pelts were pickled by the usual procedure and were tanned with basic aluminium sulphate, basic chromium sulphate and their combinations. Tanned furs were irradiated with [sup 60]Co-gamma radiations in the dose range of 5.0-114.0 kGy. The effect of radiation on the binding properties of various added substances like mineral tannins, fats, moisture and shrinkage temperature has been assessed by their comparison with the control samples. The results of these investigations show that radiation on furs causes detannage, increases the moisture and bound fat content and decreases the shrinkage temperature of the furs. (author).

  7. Deep defect levels in standard and oxygen enriched silicon detectors before and after **6**0Co-gamma-irradiation

    CERN Document Server

    Stahl, J; Lindström, G; Pintilie, I

    2003-01-01

    Capacitance Deep Level Transient Spectroscopy (C-DLTS) measurements have been performed on standard and oxygen-doped silicon detectors manufactured from high-resistivity n-type float zone material with left angle bracket 111 right angle bracket and left angle bracket 100 right angle bracket orientation. Three different oxygen concentrations were achieved by the so-called diffusion oxygenated float zone (DOFZ) process initiated by the CERN-RD48 (ROSE) collaboration. Before the irradiation a material characterization has been performed. In contrast to radiation damage by neutrons or high- energy charged hadrons, were the bulk damage is dominated by a mixture of clusters and point defects, the bulk damage caused by **6**0Co-gamma-radiation is only due to the introduction of point defects. The dominant electrically active defects which have been detected after **6**0Co-gamma-irradiation by C-DLTS are the electron traps VO//i, C//iC//s, V//2( = /-), V //2(-/0) and the hole trap C//i O//i. The main difference betwe...

  8. Gamma-ray effect on sweet potato

    International Nuclear Information System (INIS)

    Ferdes, O.; Ciofu, R.; Stroia, L.; Ghering, A.; Ferdes, M.

    1994-01-01

    The paper presents the results on modification occurred in biochemical properties of sweet potato (Ipomea batatus L.) after gamma irradiation. Two varieties, named Victoria Ianb (a white variety) and Portocaliu (a red variety), were selected and acclimatized for the agrometeorological conditions of Romania. The samples consist of roots from both usual and experimental crops. They were irradiated in batch, one week after harvesting, with a ICPR Co-60 gamma-ray source by approx. 370 TBq, dose range 100-500 Gy, dose rate 100±5 Gy/hour, dose uniformity ±5%, temperature 10 o C, 80±5% relative humidity (rh). The irradiation doses received were checked using the Fricke ferrous sulphate dosimeter procedure. The roots were kept two months at relative darkness, 6-11 o C, 60-75% rh and analyzed from time to time (initial, 5, 7, 14, 30 and 60 days). The following parameters are analyzed by conventional methods: total and reducing sugars (in De equivalent, %, on dry weight basis), starch content and the activities of sugar metabolizing enzymes. The red variety had a better behaviour towards irradiation that the white one. The sugar contents (both total and reducing), as well as starch, varied more in the white variety. The sugar metabolizing enzyme activities were influenced by both irradiation and storage conditions. Their activities were maximal at 200 and 300 Gy, and decreased significantly at higher doses. The activities also decreased in time, their variations being higher at lower doses (100 and 200 Gy). The results showed no significant influence of gamma irradiation on storage life. The modifications induced in sugar contents and enzyme activities had maximal effects at 200-300 Gy. (author)

  9. Gamma ray imager on the DIII-D tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Pace, D. C., E-mail: pacedc@fusion.gat.com; Taussig, D.; Eidietis, N. W.; Van Zeeland, M. A.; Watkins, M. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Cooper, C. M. [Oak Ridge Associated Universities, Oak Ridge, Tennessee 37830 (United States); Hollmann, E. M. [University of California-San Diego, 9500 Gilman Dr., La Jolla, California 92093-0417 (United States); Riso, V. [State University of New York-Buffalo, 12 Capen Hall, Buffalo, New York 14260-1660 (United States)

    2016-04-15

    A gamma ray camera is built for the DIII-D tokamak [J. Luxon, Nucl. Fusion 42, 614 (2002)] that provides spatial localization and energy resolution of gamma flux by combining a lead pinhole camera with custom-built detectors and optimized viewing geometry. This diagnostic system is installed on the outer midplane of the tokamak such that its 123 collimated sightlines extend across the tokamak radius while also covering most of the vertical extent of the plasma volume. A set of 30 bismuth germanate detectors can be secured in any of the available sightlines, allowing for customizable coverage in experiments with runaway electrons in the energy range of 1–60 MeV. Commissioning of the gamma ray imager includes the quantification of electromagnetic noise sources in the tokamak machine hall and a measurement of the energy spectrum of background gamma radiation. First measurements of gamma rays coming from the plasma provide a suitable testbed for implementing pulse height analysis that provides the energy of detected gamma photons.

  10. Experimental determination of gamma radiation effect from cobalt 60 on the viscosity of SSBR-B polymer

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1989-01-01

    Samples of the polymer known as SSBR-B (Solution Styrenne Butadiene Rubber-Blockade) were irradiated with gamma rays from a 60 Co source. Viscosity analysis performed by using the method of Ostwald Showed that the viscosity remains about constant for doses in the range of zero to 11560 Gray (Gy). For doses greater than 11560 Gy the viscosity increases. This result characterizes an irradiation induced hardening of the polymer. (author) [pt

  11. Response of human lymphocytes to low gamma ray doses

    International Nuclear Information System (INIS)

    Vega Carrillo, HR; Banuelos Valenzuela, R; Manzanares Acuna, E; Sanchez-Rodriguez, S.H

    2001-01-01

    Radiation and non-radiation workers lymphocytes were exposed to a low strength gamma-ray field to determine heat shock protein expression in function of radiation dose. Protein identification was carried out using mAb raised against Hsp25, Hsp60, Hsp70 and Hsp90; from these, only Hsp70 protein was detected before and after lymphocyte irradiation. In all cases, an increasing trend of relative amounts of Hsp70 in function to irradiation time was observed. After 70.5 mGy gamma-ray dose, radiation worker's lymphocytes expressed more Hsp70 protein, than non-radiation workers' lymphocytes, indicating a larger tolerance to gamma rays (gamma tolerance), due to an adaptation process developed by their labor condition (Au)

  12. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator

    International Nuclear Information System (INIS)

    2002-01-01

    This practice outlines dosimetric procedures to be followed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibration and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry storage 137 Cs or 60 Co irradiators (shielded free-standing irradiators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 5 Gy, depending on the application. The absorbed-dose rate range typically is from 10 -2 to 10 3 Gy/min. This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For procedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radiation hardness testing, see ASTM Practice E 1249. For procedures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation

  13. The effects of 60Co γ-ray irradiation on the sterilization of ready-made traditional Chinese medicine cardiac pill

    International Nuclear Information System (INIS)

    Zou Weimin; Li Lizhu; Li Xuejun

    1989-01-01

    60 Co γ-ray irradiation and epoxy-ethane treatment were used to sterilize the cardiac pill. The results showed that 60 Co γ-ray irradiation with the dosage of 4350-13050 Gy was more effective, while the epoxy-ethane treatment was not. By analyzing the sample, the bacterial number in cardiac pill treated with epoxy-ethane was more than 10,000 cells/g. The cardiac pill, however, sterilized by 60 Co γ-ray was only 0-600 cells/g, which completely correspond to the national bacteral inspect standard. In this treatment, the pharmacological analysis was done with white mice and rabbits raised with irradiated cardiac pill. The results showed that there was no abnormality in the persistence of the cardiac muscle to anemia and resistance to abnormal rhythm of the heart

  14. Pocket PC-based portable gamma-ray spectrometer

    Directory of Open Access Journals (Sweden)

    Kamontip Ploykrachang

    2011-04-01

    Full Text Available A portable gamma-ray spectrometer based on a Pocket PC has been developed. A 12-bit pipeline analog-to-digitalconverter (ADC associated with an implemented pulse height histogram function on field programmable gate array (FPGAoperating at 15 MHz is employed for pulse height analysis from built-in pulse amplifier. The system, which interfaces withthe Pocket PC via an enhanced RS-232 serial port under the microcontroller facilitation, is utilized for spectrum acquisition,display and analysis. The pulse height analysis capability of the system was tested and it was found that the ADC integralnonlinearity of ±0.45% was obtained with the throughput rate at 160 kcps. The overall system performance was tested usinga PIN photodiode-CsI(Tl crystal coupled scintillation detector and gamma standard radioactive sources of Cs-137 andCo-60. Low cost and the compact system size as a result of the implemented logical function are also discussed.

  15. Investigation of LaBr3:Ce probe for gamma-ray spectroscopy and dosimetry

    Science.gov (United States)

    Maghraby, Ahmed M.; Alzimami, K. S.; Alkhorayef, M. A.; Alsafi, K. G.; Ma, A.; Alfuraih, A. A.; Alghamdi, A. A.; Spyrou, N. M.

    2014-02-01

    The main thrust of this work is the investigation of performance of relatively new commercial LaBr3:Ce probe (Inspector 1000™ with LaBr3:Ce crystal) for gamma-ray spectroscopy and dosimetry measurements in comparison to LaCl3:Ce and NaI:Tl scintillators. The crystals were irradiated by a wide range of energies (57Co, 22Na, 18F, 137Cs and 60Co). The study involved recording of detected spectra and measurement of energy resolution, photopeak efficiency, internal radioactivity measurements as well as dose rate. The Monte Carlo package, Geant4 Application for Tomographic Emission (GATE) was used to validate the experiments. Overall results showed very good agreement between the measurements and the simulations. The LaBr3:Ce crystal has excellent energy resolution, energy resolutions of (3.37±0.05)% and (2.98±0.07)% for a 137Cs 662 keV and a 60Co 1332 keV gamma-ray point sources respectively, were recorded. The disadvantage of the lanthanum halide scintillators is their internal radioactivity. Inspector 1000™ with LaBr3:Ce scintillator has shown an accurate and quick dose measurements at Positron Emission Tomography (PET) Units which allows accurate assessment of the radiation dose received by staff members compared to the use of electronic personal dosimeters (EPD).

  16. Effect of mixed 60Co γ-rays and rare earth elements on sugar content and yield of beet

    International Nuclear Information System (INIS)

    Ma Jianzhong; Yi Huying; Yu Hongbin; Hao Yuhuai; Ma Dongyan

    2004-01-01

    The effect on sugar content and yield of beet was studied by using 60 Co γ-ray and rare earth elements (REE) to treat seeds of beet. The results indicated that 60 Co γ-ray of 50 Gy and seed-soaking in 750 g/hm 2 of farm REE could improve the root growth of beet, raise the sugar content of beetroot by 11.9% and yield by 13.5% compared to that of CK. The differences reached the significant level. (authors)

  17. Effect of mixed 60Co γ-rays and rare earth elements on sugar content and yield of beet

    International Nuclear Information System (INIS)

    Ma Jianzhong; Yi Huying; Yu Hongbin; Hao Yuhuai

    2004-01-01

    The effect on sugar content and yield of beet was studied by using 60 Co γ-ray and rare earth elements (REE) to treat seeds of beet. The results indicated that 60 Co γ-ray of 50 Gy and seed-soaking in 750 g/hm 2 of farm REE could improve the root growth of beet, raise the sugar content of beetroot by 11.9% and yield by 13.5% compared to that of CK. The differences reached the significant level

  18. Effect of Co-60 gamma irradiated chitosan and phosphorus fertilizer on growth, yield and trigonelline content of Trigonella foenum-graecum L.

    Directory of Open Access Journals (Sweden)

    Tariq Ahmad Dar

    2015-07-01

    Full Text Available Natural marine polysaccharides such as chitosan, sodium alginate and carrageenan; after depolymerization by different techniques, have shown promising plant growth promoting and other biological activities. Chitosan after irradiation with Co-60 gamma-rays have proven to be a miraculous plant growth promoter in different plants. Trigonelline; an anti-diabetic compound is obtained mainly from the seeds of Fenugreek (Trigonella foenum-graecum L.. Trigonelline counteracts diabetes mellitus (DM through the operation of the mechanisms of insulin secretion, modulation of β-cell regeneration and stimulation of activity of glucose metabolism related enzymes. Considering the medicinal importance a pot experiment was conducted to investigate the effect of foliar application of Co-60 gamma irradiated chitosan (IC with soil applied phosphorus supplement on growth, biochemical and quality attributes of fenugreek. Four concentrations of irradiated chitosan were used (0, 40, 80 and 120 mg L−1 individually as well as in combination with single dose of phosphorus 40 kg ha−1. Un-irradiated chitosan (UN 40 mg L−1 and de-ionized water were used as control. IC significantly affected almost all the parameters including seed yield, trigonelline content and trigonelline yield. There were 10 treatments and among all, P40 + IC 40 mg L−1 proved to be the best, which increased total alkaloid content by 34.9%, seed yield by 125.4%, and trigonelline content by 17.8%. Contents of photosynthetic pigments and activity of nitrate reductase, carbonic anhydrase enzymes were also significantly enhanced.

  19. Morphological and histological studies on freshwater prawn Macrobrachium rosenbergii (de man) irradiated with {sup 60}Co gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Stalin, A.; Broos, K.V. [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Sadiq Bukhari, A., E-mail: abjmc@yahoo.in [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Syed Mohamed, H.E. [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Singhal, R.K. [Analytical Spectroscopy Section, Analytical Chemistry Division, Bhabha Atomic Research Center, Trombay, Mumbai 4000085 (India); Venu-Babu, P. [Nuclear Agriculture and Biotechnology Division, Bhabha Atomic Research Center, Trombay, Mumbai 4000085 (India)

    2013-11-15

    Graphical abstract: -- Highlights: •Analyzing the impact of {sup 60}Co gamma radiation (low doses) in M. rosenbergii. •LD{sub 50} identified in 30 Gy; Irradiated exhibits morphological changes than control. •Significantly decreased HSI and histological changes in irradiated groups. •Aberration severities increased as increased of dose level. •Biomonitoring tool in determining low dose radiation pollution in aquatic ecosystem. -- Abstract: This study was framed to investigate the {sup 60}Co gamma radiation induced morphological and histological variations in freshwater prawn Macrobrachium rosenbergii. The LD{sub 50} value of {sup 60}Co gamma irradiated M. rosenbergii observed (by probit analysis) at 30 Gy. Prawns were irradiated to four different dose levels (3 mGy, 30 mGy, 300 mGy and 3000 mGy) using Theratron Phoenix TeleCobalt Unit [P-33] and one control group (without irradiation) maintained separately. Irradiated groups exhibited several morphological variations such as discoloration; damaged rostrum; opaque coloration in cephalothorax; black bands and dot formation in abdomen; deformed uropods and telson in tail regions when compared with control group. The Hepato Somatic Index reflected the severity of radiation on hepatopancreas. Histological variations in gills, hepatopancreas and muscles of irradiated groups were observed. In gills, structural changes such as swollen and fused lamellae, abnormal gill tips, hyperplasic, necrotic and clavate-globate lamellae were observed in gamma irradiated prawns. Accumulation of hemocytes in hemocoelic space, interstitial sinuses filled with abnormal infiltrated hemocytes, the tubular epithelium with ruptured basal laminae, abnormal and coagulated lumen, necrotic tubules, thickened basal laminae, tissue debris, necrotic hepatocytes were observed in irradiated prawn hepatopancreas. In muscle, shrinkage of muscular fiber and necrotic musculature were observed in irradiated prawns. These structural alterations of

  20. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  1. The Co-60 gamma-ray irradiation effects on the Al/HfSiO4/p-Si/Al MOS capacitors

    Science.gov (United States)

    Lok, R.; Kaya, S.; Karacali, H.; Yilmaz, E.

    2017-12-01

    In this work, the initial interface trap density (Nit) to examine device compability for microelectronics and then the Co-60 gamma irradiation responses of Al/HfSiO4/p-Si/Al (MOS) capacitors were investigated in various dose ranges up to 70 Gy. Pre-irradiation response of the devices was evaluated from high frequency (HF) and low frequency (LF) capacitance method and the Nit was calculated as 9.91 × 1011 cm-2 which shows that the HfSiO4/p-Si interface quality is convenient for microelectronics applications. The irradiation responses of the devices were carried out from flat-band and mid-gap voltage shifts obtained from stretch of capacitance characteristics prior to and after irradiation. The results show that the flat band voltages very slightly shifted to positive voltage values demonstrating the enhancement of negative charge trapping in device structure. The sensitivity of the Al/HfSiO4/p-Si/Al MOS capacitors was found to be 4.41 mV/Gy for 300 nm-thick HfSiO4 gate dielectrics. This value approximately 6.5 times smaller compared to the same thickness conventional SiO2 based MOS devices. Therefore, HfSiO4 exhibits crucial irradiation tolerance in gamma irradiation environment. Consequently, HfSiO4 dielectrics may have significant usage for microelectronic technology as a radiation hard material where radiation field exists such as in space applications.

  2. Upgrade of the JET gamma-ray cameras

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Anghel, M.; Constantin, M.; David, E.; Craciunescu, T.; Falie, D.; Pantea, A.; Tiseanu, I.; Kiptily, V.; Prior, P.; Edlington, T.; Griph, S.; Krivchenkov, Y.; Loughlin, M.; Popovichev, S.; Riccardo, V; Syme, B.; Thompson, V.; Lengar, I.; Murari, A.; Bonheure, G.; Le Guern, F.

    2007-01-01

    Full text: The JET gamma-ray camera diagnostics have already provided valuable information on the gamma-ray imaging of fast ion in JET plasmas. The applicability of gamma-ray imaging to high performance deuterium and deuterium-tritium JET discharges is strongly dependent on the fulfilment of rather strict requirements for the characterisation of the neutron and gamma-ray radiation fields. These requirements have to be satisfied within very stringent boundary conditions for the design, such as the requirement of minimum impact on the co-existing neutron camera diagnostics. The JET Gamma-Ray Cameras (GRC) upgrade project deals with these issues with particular emphasis on the design of appropriate neutron/gamma-ray filters ('neutron attenuators'). Several design versions have been developed and evaluated for the JET GRC neutron attenuators at the conceptual design level. The main design parameter was the neutron attenuation factor. The two design solutions, that have been finally chosen and developed at the level of scheme design, consist of: a) one quasi-crescent shaped neutron attenuator (for the horizontal camera) and b) two quasi-trapezoid shaped neutron attenuators (for the vertical one). The second design solution has different attenuation lengths: a short version, to be used together with the horizontal attenuator for deuterium discharges, and a long version to be used for high performance deuterium and DT discharges. Various neutron-attenuating materials have been considered (lithium hydride with natural isotopic composition and 6 Li enriched, light and heavy water, polyethylene). Pure light water was finally chosen as the attenuating material for the JET gamma-ray cameras. The neutron attenuators will be steered in and out of the detector line-of-sight by means of an electro-pneumatic steering and control system. The MCNP code was used for neutron and gamma ray transport in order to evaluate the effect of the neutron attenuators on the neutron field of the

  3. Basics of Gamma Ray Detection

    Energy Technology Data Exchange (ETDEWEB)

    Stinnett, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Venkataraman, Ram [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-13

    The objective of this training is to explain the origin of x-rays and gamma rays, gamma ray interactions with matter, detectors and electronics used in gamma ray-spectrometry, and features of a gamma-ray spectrum for nuclear material that is safeguarded.

  4. Delignification of Sawdust White Teak (Gmelina arborea Roxb. by Fungi Phanerochaete chrysosporium Irradiated Gamma Ray

    Directory of Open Access Journals (Sweden)

    Nurhasni Nurhasni

    2016-12-01

    , pretreatment of substrate wood white teak (Gmelina arborea Roxb. Using a solution of NaOH 1% and H2SO4 1% and gamma-ray irradiation Co-60, have the power of ionization is small, high penetrating power, and Co-60 which can emit gamma rays a short half-life time. This research was conducted in two stages, the first stage of determining the optimum dose gamma irradiation for fungi Phanerochaete chrysosphorium (0 Gy, 200 Gy, 400 Gy, 600 Gy, 800 Gy, and 1000 Gy and the second stage of the analysis of the characteristics of the substrate wood white teak has been in pretreatment by methode Solid State Fermentation (SSF for 21 days. The results showed that the optimum dose administration of gamma irradiation on fungi Phanerochaete chrysosphorium is a dose of 600 Gy which can increase the activity of enzymes lignin peroxidase (LiP amounted to 22.18 U / mL. Chemical pretreatment process using H2SO4 1% biodelignification can accelerate the process of lignin degradation that produces the highest efficiency of 25.65%.   Keywords: Lignocellulose, delignification, Solid State Fermentation (SSF, Phanerochaete chrysosporium, gamma irradiation. DOI: http://dx.doi.org/10.15408/jkv.v0i0.3079

  5. Method of incident low-energy gamma-ray direction reconstruction in the GAMMA-400 gamma-ray space telescope

    International Nuclear Information System (INIS)

    Kheymits, M D; Leonov, A A; Zverev, V G; Galper, A M; Arkhangelskaya, I V; Arkhangelskiy, A I; Yurkin, Yu T; Bakaldin, A V; Suchkov, S I; Topchiev, N P; Dalkarov, O D

    2016-01-01

    The GAMMA-400 gamma-ray space-based telescope has as its main goals to measure cosmic γ-ray fluxes and the electron-positron cosmic-ray component produced, theoretically, in dark-matter-particles decay or annihilation processes, to search for discrete γ-ray sources and study them in detail, to examine the energy spectra of diffuse γ-rays — both galactic and extragalactic — and to study gamma-ray bursts (GRBs) and γ-rays from the active Sun. Scientific goals of GAMMA-400 telescope require fine angular resolution. The telescope is of a pair-production type. In the converter-tracker, the incident gamma-ray photon converts into electron-positron pair in the tungsten layer and then the tracks are detected by silicon- strip position-sensitive detectors. Multiple scattering processes become a significant obstacle in the incident-gamma direction reconstruction for energies below several gigaelectronvolts. The method of utilising this process to improve the resolution is proposed in the presented work. (paper)

  6. Influence of 60Co gamma radiation on fluorine plasma treated enhancement-mode high-electron-mobility transistor

    International Nuclear Information System (INIS)

    Quan Si; Hao Yue; Ma Xiao-Hua; Yu Hui-You

    2011-01-01

    AlGaN/GaN depletion-mode high-electron-mobility transistor (D-HEMT) and fluorine (F) plasma treated enhancement-mode high-electron-mobility transistor (E-HEMT) are exposed to 60 Co gamma radiation with a dose of 1.6 Mrad (Si). No degradation is observed in the performance of D-HEMT. However, the maximum transconductance of E-HEMT is increased after radiation. The 2DEG density and the mobility are calculated from the results of capacitance-voltage measurement. The electron mobility decreases after fluorine plasma treatment and recovers after radiation. Conductance measurements in a frequency range from 10 kHz to 1 MHz are used to characterize the trapping effects in the devices. A new type of trap is observed in the F plasma treated E-HEMT compared with the D-HEMT, but the density of the trap decreases by radiation. Fitting of G p /ω data yields the trap densities D T = (1 − 3) × 10 12 cm −2 · eV −1 and D T = (0.2 − 0.8) × 10 12 cm −2 · eV −1 before and after radiation, respectively. The time constant is 0.5 ms-6 ms. With F plasma treatment, the trap is introduced by etch damage and degrades the electronic mobility. After 60 Co gamma radiation, the etch damage decreases and the electron mobility is improved. The gamma radiation can recover the etch damage caused by F plasma treatment. (interdisciplinary physics and related areas of science and technology)

  7. Egg weight and gamma-rays effects. Pt. 1

    International Nuclear Information System (INIS)

    Shebaita, M.K.; Ezzat, I.E.; Kamar, G.A.R.

    1979-01-01

    Two groups of egg weight from Egyptian Fayoumi breed were used in this study. The first group ranged in weight from 36-43 grams (group A) and the second group ranged from 44-50 grams (group B). Each egg weight group was divided to 6 exposure treatments to 60 Co gamma rays (non-irradiated, 150 rads, 300 rads, 450 rads, 600 rads and 750 rads). The data showed that embryonic mortality was 75% higher in irradiated treatments compared with the non-irradiated, and 50% of the mortality occurred during the first 5 days after the exposure. Moreover, mortality was 18% higher in group A than in group B. However, the abnormality was 6.4% in group A and 10.8% in group B. A delay in hatching time was observed and the hatching percent decreased due to the exposure to gamma rays. The relationship between hatching % (Y) and the dose level (X) was Y = 86.6 esup(-0.00041x) in group A and Y = 85.5 esup(-0.00028x) in group B. On the other hand, the hatching weight in irradiated treatments was higher (P [de

  8. Natural background gamma-ray spectrum. List of gamma-rays ordered in energy from natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Ichimiya, Tsutomu [Japan Radioisotope Association, Tokyo (Japan); Narita, Tsutomu; Kitao, Kensuke

    1998-03-01

    A quick index to {gamma}-rays and X-rays from natural radionuclides is presented. In the list, {gamma}-rays are arranged in order of increasing energy. The list also contains {gamma}-rays from radioactive nuclides produced in a germanium detector and its surrounding materials by interaction with cosmic neutrons, as well as direct {gamma}-rays from interaction with the neutrons. Artificial radioactive nuclides emitting {gamma}-rays with same or near energy value as that of the natural {gamma}-rays and X-rays are also listed. In appendix, {gamma}-ray spectra from a rock, uranium ore, thorium, monazite and uraninite and also background spectra obtained with germanium detectors placed in iron or lead shield have been given. The list is designed for use in {gamma}-ray spectroscopy under the conditions of highly natural background, such as in-situ environmental radiation monitoring or low-level activity measurements, with a germanium detector. (author)

  9. Effect of 60Co γ-rays irradiation on rice straw fibre structure and enzyme hydrolyzation

    International Nuclear Information System (INIS)

    Chen Jingping; Li Wenge; Peng Ling; Wang Keqin; Xiong Xingyao

    2008-01-01

    The effect of improving enzyme hydrolyze of rice straw was estimated with treating dry rice straw and raw fiber by 60 Co γ-rays irradiation. the water-soluble deoxidize carbohydrate and total carbohydrate of 60 Co γ-rays irradiated rice straw and raw fibres were measured by DNS method and vitrol-phenol method. The changes of deoxidize carbohydrate groups of irradiated hydrolyzing rice straw were analyzed by gas chromatography. The organism structures of irradiated rice straw were scanned by electron microscope, the results showed that 1000-1500 kGy 60 Co γ-irradiation doses effectively destroyed rice straw's organism structures, especially the silicon crystal structures, and along with irradiation doses increased the breakage degree enlarged significantly. The contents of the water-soluble deoxidize carbohydrate and total carbohydrate of rice straw increased significantly. treated by both irradiation and enzyme, the cellulose transform rate of rice straw was 88.7%, which is better than that only treated by 60 Co γ-irradiation or enzyme. The content of water-solubility deoxidize carbohydrate of the treated rice straw was 214.4 mg/g and the total carbohydrate of straw was 758.5 mg/g. The contents of mannose, galactose, glucose, arabinose and xylose increased significantly, among those carbohydrate, the glucose's increment was the largest and account for 62.64%, and mannose's increments was the second. The contents of lignin of the rice straw were not influenced obviously by irradiation treatment. (authors)

  10. Gamma radiation (Co60) effects on active substances and microbe burden of medicinal plants

    International Nuclear Information System (INIS)

    Dall'Agnol, L.

    2001-01-01

    In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co 60 ). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific analytical methods are recommended to verify possible structural alterations in active vegetal molecules. (author)

  11. Effect of γ-rays Co60 on the fermentation activity of Saccharomyces Vini

    International Nuclear Information System (INIS)

    Talipova, Sh.; Gulyamova, N.; Balasanyan, I.A.

    1978-01-01

    The fermentation activity of the local strains of yeast Saccharomyces vini, irradiated with the doses of 150-200 Krad of Co gamma-rays is studied. The strains effective for viniculture have been selected. It is noted that in irradiated yeast at the dose of 200 krad fermentation activity is enhanced, i.e. the rate and the energy of fermentation are increased. It has been found that irradiated yeast strains will completely ferment grape 24 hours earlier than in the control group. Wine prepared with irradiated strains by organoleptic indices is better than wine made with the Rkatsiteli-6 control industrial race

  12. Acción protectora de la melatonina sobre células mononucleares de sangre periférica humana sometidas a radiación gamma Co60

    Directory of Open Access Journals (Sweden)

    Martha Mesa-Villanueva

    2009-04-01

    Full Text Available Protective action of melatonin on human peripheral blood mononuclear cells exposed to gamma radiation Co60. Objective: toevaluate the protective effect of melatonin on peripheral blood mononuclear cells (PBMCs exposed in vitro to ionizing radiation. Materialsand methods: PBMCs drawn from healthy volunteers were incubated with 0, 1x10-5, 1x10-6 y 1x10-7 M melatonin for 10 minutes beforebeing exposed to gamma radiation (300 cGy; Co60 source. Afterwards, DNA damage was evaluated with the comet assay. Results:PBMCs pretreated with melatonin showed comet tails shorter than those without the hormone treatment, as well as a lower percentage ofcells with severe DNA damage. Conclusion: melatonin doses of 1x10-5, 1x10-6 and 1x10-7 M provide in vitro protection to PBMCs fromDNA damage (single strand breaks and alkali-labile sites induced by gamma radiation (300 cGy; Co60 source.

  13. The teratogenic effects of low dose 60Co γ-rays on the early pregnant rats

    International Nuclear Information System (INIS)

    Lu Chunlin

    1991-01-01

    The pregnant Wistar rats were exposed to 0.5 Gy and 1.0 Gy 60 Co γ-rays at the 9th day after conception. The results: 60 Co γ-rays at dose of 1.0 Gy could induced many defects: excenphaly, hydrocephalus, gastroschisis, cleft palate and cleft lip, anophthalmia, microphthalmia, shorten tail and absent tail in surviving fetuses. The growth retardation was found from the parameters of fetal weight, height, head circle and development of skeleton. In the group of radiation dose 0.5 Gy, only hydrocephalus, absent tail and growth retardation of skeleton appeared. The results suggest that low-dose exposure in the early pregnant rats can induce fetal defects and growth retardation. The probable mechanism of teratogen and growth retardation was discussed. The cAMP levels of brain and liver of rat fetuses were reported

  14. Study on the energy dependence of gamma radiation detectors for {sup 137}Cs and {sup 60}Co; Estudo da dependencia energetica de detectores de radiacao gama para {sup 137}Cs e {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda B.C.; Diniz, Raphael E.; Carvalho, Valdir S.; Vivolo, Vitor; Caldas, Linda V.E., E-mail: fbnonato@ipen.b, E-mail: rediniz@ipen.b, E-mail: vcsouza@ipen.b, E-mail: vivolo@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    38 Geiger-Mueller radiation detectors and 9 ionization chambers were calibrated, viewing to study the energy dependence of the monitor response for gamma radiation fields ({sup 137}Cs and {sup 60}Co). The results were considered satisfactory only for ionization chambers and for some Geiger-Mueller detectors

  15. Effect of 60Co γ-ray irradiation on salmonella in high immunity egg yolk

    International Nuclear Information System (INIS)

    Ma Haili; Han Keguang; Zheng Mingxue; Li Guozhu

    2002-01-01

    Salmonella were inoculated into the yolk and irradiated with different dose of 60 Co γ-ray. The results show that 3 kGy irradiation dose can kill all Salmonella in the yolk and D 10 value of Salmonella in the yolk is 0.36-0.46 kGy

  16. The effects of 60Co γ-ray irradiation on cytoplasmic microtubules of mouse macrophages and lymphocytes

    International Nuclear Information System (INIS)

    Li Qianqian; Mao Zijun; Yin Zhiwei; Hu Yumin

    1989-05-01

    The effects of 60 Co γ-ray irradiation on cytoplasmic microtubules of mouse macrophages and lymphocytes were investigated by immunofluorescence microscopy and scanning electron microscope. The results indicated. (1) microtubule organization of the irradiated cells remarkably differed from that of the control since the doses over 4 Gy; (2) 144 hours after irradiation the alterations of microtubules have been shown to be basically r epaired ; (3) the cytoplasmic microtubules and centrioles disappeared under transmission electron microscope, the membranes irradiated and microvilli showed changes under scanning electron microscope too. From these observations and those of other workers who studied the radiation effect on extracted microtubule proteins in vitro, the authors support that 60 Co γ-ray irradiation can inhabits cytoplasmic microtubule assembling

  17. Effect of 60Co γ-rays irradiation pretreatment on callus inductivity and differentiation of strawberry anther

    International Nuclear Information System (INIS)

    Zhang Huiqin; Xie Ming; Jiang Guihua; Sun Congbo; Huang Pule; Wu Yanjun; Wu Qing

    2007-01-01

    Strawberry buds, in which a majority of pollen had single nuclear keeping to the side, were pretreated by 60 Co γ-rays irradiation at different doses. The irradiation effect on the callus inductivity and plant differentiation rate of strawberry anther were studied. The results indicated that the pretreatment by 60 Co γ-rays could increase the anther callus inductivity and plant differentiation rate significantly, and 20 Gy was the best dose. The callus inductivity of Akihime and Toyonoka increased by 39.09% and 35.68%, respectively, compared with the no-pretreatment materials. On the same media, the plant differentiation rate of Akihime and Toyonoka were also increased by 6.67%-6.72% and 4.73%-6.45%, respectively, compared with the two varieties of no-pretreatment. (authors)

  18. Influence of beta radiation from tritium and gamma radiation from 60Co on the biological half-times of organically bound tritium

    International Nuclear Information System (INIS)

    Radwan, I.

    1981-01-01

    The influence of beta radiation from tritium on the biological half-times of organically bound tritium in particular tissues of the rat is compred with the influence of fractionated gamma radiation from 60 Co. (M.F.W.)

  19. Relative biological effectiveness measurements using murine lethality and survival of intestinal and hematopoietic stem cells after Fermilab neutrons compared to JANUS reactor neutrons and 60Co gamma rays

    International Nuclear Information System (INIS)

    Hanson, W.R.; Crouse, D.A.; Fry, R.J.M.; Ainsworth, E.J.

    1984-01-01

    The relative biological effectiveness (RBE) of the 25-MeV (average energy) neutron beam at the Fermi National Accelerator Laboratory was measured using murine bone marrow (LD/sub 50/30/) and gut (LD/sub 50/6/) lethality and killing of hematopoietic colony forming units (CFU-S) or intestinal clonogenic cells (ICC). The LD/sub 50/30/ and LD/sub 50/6/ for mice exposed to the Fermilab neutron beam were 6.6 and 8.7 Gy, respectively, intermediate between those of JANUS neutrons and 60 Co γ rays. The D 0 values for CFU-S and ICC were 47 cGy and 1.05 Gy, respectively, also intermediate between the lowest values found for JANUS neutrons and the highest values found after 60 Co γ rays. The split-dose survival ratios for CFU-S at intervals of 1-6 hr between doses were essentially 1.0 for both neutron sources. The 3-hr split-dose survival ratios for ICC were 1.0 for JANUS neutrons, 1.85 for Fermilab neutrons, and 6.5 for 60 Co γ rays. The RBE estimates for LD/sub 50/30/ were 1.5 and 2.3 for Fermilab and JANUS neutrons, respectively. Based on LD/sub 50/6/, the RBEs were 1.9 (Fermilab) and 3.0 (JANUS). The RBEs for CFU-S D 0 were 1.4 (Fermilab) and 1.9 (JANUS) and for jejunal microcolony D 0 1.4 (Fermilab) and 2.8 (JANUS)

  20. X-ray and gamma-ray standards for detector calibration

    International Nuclear Information System (INIS)

    1991-09-01

    The IAEA established a Co-ordinated Research Programme (CRP) on the Measurements and Evaluation of X- and Gamma-Ray Standards for Detector Efficiency Calibration in 1986 with the aim of alleviating the generation of such discrepancies. Within the framework of this CRP, representatives of nine research groups from six Member States and one international organization performed a number of precise measurements and systematic in-depth evaluations of the required decay data. They have also contributed to the development of evaluation methodology and measurement techniques, and stimulated a number of such studies at laboratories not directly involved in the IAEA project. The results of the work of the CRP, which was finished in 1990, are presented in this report. Recommended values of half-lives and photon emission probabilities are given for a carefully selected set of radionuclides that are suitable for detector efficiency calibration (X-rays from 5 to 90 keV and gamma-rays from 30 to about 3000 keV). Detector efficiency calibration for higher gamma-ray energies (up to 14 MeV) is also considered. The evaluation procedures used to obtain the recommended values and their estimated uncertainties are reported, and a summary of the remaining discrepancies is given. Refs and tabs

  1. X-ray echoes from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dermer, C.D.; Hurley, K.C.; Hartmann, D.H.

    1991-01-01

    The identification of an echo of reflected radiation in time histories of gamma-ray burst spectra can provide important information about the existence of binary companions or accretion disks in gamma-ray burst systems. Because of the nature of Compton scattering, the spectrum of the echo will be attenuated at gamma-ray energies compared with the spectrum of the primary burst emission. The expected temporal and spectral signatures of the echo and a search for such echoes are described, and implications for gamma-ray burst models are discussed. 35 refs

  2. Cosmic and solar gamma-ray x-ray and particle measurements from high altitude balloons in Antarctica

    International Nuclear Information System (INIS)

    Lin, R.P.

    1990-01-01

    For measurements of cosmic and solar gamma-rays, hard X-rays, and particles, Antarctica offers the potential for very long, 10--20 day, continuous, twenty-four-hour-a-day observations, with balloon flights circling the South Pole during austral summer. For X-ray/gamma-ray sources at high south latitude the overlying atmosphere is minimized, and for cosmic ray measurements the low geomagnetic cutoff permits entry of low rigidity particles. The first Antarctic flight of a heavy (∼2400 lb.) payload on a large (11.6x10 6 cu. ft.) balloon took place in January, 1988, to search for the gamma-ray lines of 56 Co produced in the new supernova SN 1987A in the Large Magellanic Cloud. The long duration balloon flights presently planned from Antarctica include those for further gamma-ray/hard X-ray studies of SN 1987A and for the NASA Max '91 program for solar flare studies

  3. Computer program SCAP-BR for gamma-ray streaming through multi-legged ducts

    International Nuclear Information System (INIS)

    Byoun, T.Y.; Babel, P.J.; Dajani, A.T.

    1977-01-01

    A computer program, SCAP-BR, has been developed at Burns and Roe for the gamma-ray streaming analysis through multi-legged ducts. SCAP-BR is a modified version of the single scattering code, SCAP, incorporating capabilities of handling multiple scattering and volumetric source geometries. It utilizes the point kernel integration method to calculate both the line-of-sight and scattered gamma dose rates by employing the ray tracing technique through complex shield geometries. The multiple scattering is handled by a repeated process of the single scatter method through each successive scatter region and collapsed pseudo source meshes constructed on the relative coordinate systems. The SCAP-BR results have been compared with experimental data for a Z-type (three-legged) concrete duct with a Co-60 source placed at the duct entrance point. The SCAP-BR dose rate predictions along the duct axis demonstrate an excellent agreement with the measured values

  4. The Gamma-ray Sky with Fermi

    Science.gov (United States)

    Thompson, David

    2012-01-01

    Gamma rays reveal extreme, nonthermal conditions in the Universe. The Fermi Gamma-ray Space Telescope has been exploring the gamma-ray sky for more than four years, enabling a search for powerful transients like gamma-ray bursts, novae, solar flares, and flaring active galactic nuclei, as well as long-term studies including pulsars, binary systems, supernova remnants, and searches for predicted sources of gamma rays such as dark matter annihilation. Some results include a stringent limit on Lorentz invariance derived from a gamma-ray burst, unexpected gamma-ray variability from the Crab Nebula, a huge gamma-ray structure associated with the center of our galaxy, surprising behavior from some gamma-ray binary systems, and a possible constraint on some WIMP models for dark matter.

  5. The effect of 60Co γ-rays on con A and LPS induced lymphocytes

    International Nuclear Information System (INIS)

    Su Liaoyuan; Liu Keliang; Ma Xiangrui

    1987-01-01

    The effect of 60 Co γ-rays on lymphocytes induced by Con A and LPS and the relationship between these two groups of cells were investigated by means of 3 H-TdR incorporation. The study showed that in vitro, Con A cells were able to promote the inducing effect of LPS to B cells. When Con A cells were irradiated by 10 Gy γ-rays, the 3 H-TdR incorporation value reduced significantly and the stimulating effect of Con A cells on LPS cells disappeared. Having been irradiated by γ-rays, LPS cells were not be able to be stimulated by normal Con A cells. When the groups of cells were incubated together after irradiation, the synergistic function disappeared, furthermore the suppressive effect of Con A cells on LPS cells emerged. When these two groups of cells were investigated by means of agar culture, the suppressive effect of 10 Gy γ-rays on lymphocytes colony formation was more obvious. Tests on 7 patients who were suffering from carcinoma of nasoparynx showed that after a course of treatment with 60 Co γ-rays, the incorporation value in Con A cells became much smaller, the stimulating effect of Con A cells on LPS cells disappeared. LPS cells could not be stimulated by normal Con A cells. The study demonstrated that the radiosensitivity of Con A cells is higher than that of LPS cells

  6. Measurement of high dose rates of 60Co by gamma activation of115In and 111Cd foils

    International Nuclear Information System (INIS)

    Haddad, Kh; Qattan, M.; Taleb, A.

    2009-12-01

    The high gamma dose rate measurement technique using nuclear reaction (γ,(γ ' ') was introduced in this work. This technique is cheap, easy, reliable, and independent of chemical and physical factors, which affect other techniques. The response to the absorbed dose in this technique is linear and can be used for high dose. Cd and In foils were irradiated using 60 Co source and the resulted isomer activities were measured using gamma spectrometer. These foils were calibrated to be used as dosemeter and its results were compared with conventional one. The dose distribution in the irradiation field was determined using In foils. (authors)

  7. Applied gamma-ray spectrometry

    CERN Document Server

    Dams, R; Crouthamel, Carl E

    1970-01-01

    Applied Gamma-Ray Spectrometry covers real life application of the gamma-ray and the devices used in their experimental studies. This book is organized into 9 chapters, and starts with discussions of the various decay processes, the possible interaction mechanisms of gamma radiation with matter, and the intrinsic and extrinsic variables, which affect the observed gamma-ray and X-ray spectra. The subsequent chapters deal with the properties and fabrication of scintillation detectors, semiconductor detectors, and proportional gas counters. These chapters present some of the most widely utilized

  8. Measurement of the G-value for 1. 5 keV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, J.P.; Schillaci, M.E.; Raju, M.R. (Los Alamos National Lab., NM (USA))

    1989-12-01

    Using a ferrous sulfate solution modified by the addition of benzoic acid, the authors measured relative G-values for Al{sub k} characteristic X-rays (1.5keV), {sup 238}Pu {alpha}-particles (3.7MeV), {sup 60}Co (1.17 MeV) and {sup 137}Cs (0.66 MeV){gamma}-rays. Relative ferrous-to-ferric conversions as a function of dose were similar for the two {gamma}-ray energies, yielding G-values of 1.62 and 1.59 {mu}mol J{sup -1} for the {sup 60}Co and {sup 137}Cs radiations. The {alpha}-particle G-value was 0.52 {mu}mol J{sup -1}, or 31% of that for {sup 60}Co {gamma}-rays. The Al{sub k} X-rays had a G-value of 0.92 {mu}mol J{sup -1} or 57% of that of the {sup 60}Co radiation. This G-value for 1.5 keV X-rays is within 20% of values predicted by current theories, and theoretical values are within the error range of the authors' measurements. (author).

  9. Use of 60Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    International Nuclear Information System (INIS)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A.

    2013-01-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from 60 Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from 60 Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  10. Effects of combination treatment of 60Co γ-rays irradiation and no on alkaloid production and plbs growth of hybrid dendrobium

    International Nuclear Information System (INIS)

    Jin Qing; Cai Yongping; Lin Yi; Lu Ruihong

    2010-01-01

    The effects of 60 Co γ-rays irradiation, SNP (sodium nitroprusside, used as the donor) alone and their combination treatments on the alkaloids production and protocorm-like bodies (PLBs) growth were investigated in suspension cultures of Hybrid dendrobium. The results showed that either 60 Co γ-rays or SNP, and their combined treatments could enhance the accumulation of alkaloids, but restricted the PLBs growth, especially the combined treatments had the accumulative effect on the alkaloids production. The alkaloids content achieved 0.0676% with the optimum combined treatment of 0.1 mmol/L sodium nitroprusside and 10 Gy 60 Co γ-rays irradiation. The alkaloids production of unit medium was 6.35-fold higher than that in untreated PLBs cultures and was significantly different from the treatment of 60 Co γ-rays or SNP at P < 0.01 level. Both Nw-Nitro-L-arginine methl ester hydrochloride and carboxy 2-phenyl-4, 4, 5, 5-tetramethylimidazoline-1-oxyl 3-oxide inhibitors could inhibit the accumulation of alkaloids. With the combined treatment, the activities of POD, SOD and CAT were changed, which perhaps mediated the alkaloids production and PLBs growth. (authors)

  11. Collimatorless imaging of gamma rays with help of gamma-ray tracking

    CERN Document Server

    Marel, J V D

    2001-01-01

    In many gamma-ray detector systems that are built for imaging purposes Compton scattered photons are suppressed as much as possible. However, the information from photons that scattered inside a detector system can be used to reconstruct the tracks of the photons with help of gamma-ray tracking. Estimates of the incident directions of the photons can be made and an image can be created. Examples of potential applications for this technique are the use as a gamma-camera in medical imaging (e.g. SPECT) or as a detector for PET. Due to the omission of collimators, much higher detection efficiencies can be achieved, reducing the doses required for an image. A gamma-ray tracking method, called backtracking, has been developed for nuclear spectroscopy. The method tracks gamma-rays originating from a point source in the center of a spherical detector system consisting of position-sensitive germanium detectors. This method can also be used as a tracking technique for imaging of an unknown source distribution. With he...

  12. A gamma-ray tracking detector for molecular imaging

    International Nuclear Information System (INIS)

    Hall, C.J.; Lewis, R.A.; Helsby, W.I.; Nolan, P.; Boston, A.

    2003-01-01

    A design for a gamma-ray detector for molecular imaging is presented. The system is based on solid-state strip detector technology. The advantages of position sensitivity coupled with fine spectral resolution are exploited to produce a tracking detector for use with a variety of isotopes in nuclear medicine. Current design concepts employ both silicon and germanium layers to provide an energy range from 60 keV to >1 MeV. This allows a reference X-ray image to be collected simultaneously with the gamma-ray image providing accurate anatomical registration. The tracking ability of the gamma-ray detector allows ambiguities in the data set to be resolved which would otherwise cause events to be rejected in standard non-tracking system. Efficiency improvements that high solid angle coverage and the use of a higher proportion of events make time resolved imaging and multi-isotope work possible. A modular detector system, designed for viewing small animals has been accepted for funding

  13. Aspects of the immune response against proteic antigens submitted to the effects of 60Co gamma radiation

    International Nuclear Information System (INIS)

    Alves, Janaina Baptista.

    2004-01-01

    Considering the effects of gamma radiation on proteins and the capacity of the immune system to recognize modified macromolecules, we decided to evaluate some immunological aspects of B10.PL mice exposed to native or irradiated ovalbumin and bothrops toxin-1 (BthTx-1). In order to evaluate possible structural modifications of the molecules after being irradiated ( 60 Co gamma rays), bothrops toxin-1 was analysed by electrophoresis, while ovalbumin was submitted to analytical size exclusion chromatography. The toxin was also analysed by ESI-mass spectrometry. Our results indicate that radiation promoted modifications on both the molecules. Aiming to compare the toxicity of the native and irradiated forms of the toxin, an in vitro cytotoxicity assay, using CHO cells, was performed. According to our results, the modified toxin was 5 folds less toxic than its native counterpart. Sera of animals immunized with the native and irradiated proteins were analyzed in order to evaluate levels of IgG, as well as to quantify specific isotopes. While the native proteins induced a predominant Th2 response, the irradiated molecules apparently promoted a switch towards a Th1 pattern. We also performed a cell proliferation assay with splenocytes from mice immunized with either the native or the irradiated proteins, cultured in the presence of the antigens. Our results indicate that both the forms of the proteins induced a similar proliferative response. These data indicate a potential use of detoxified proteins as antigens for immunization. (author)

  14. Optical observations of Gamma-Ray Bursts

    International Nuclear Information System (INIS)

    Hjorth, J.; Pian, E.; Fynbo, J.P.U.

    2004-01-01

    We briefly review the status and recent progress in the field of optical observations of gamma-ray burst afterglows. We will focus on the fundamental observational evidence for the relationship between gamma-ray bursts and the final evolutionary phases of massive stars. In particular, we will address (i) gamma-ray burst host galaxies, (ii) optically dark gamma-ray burst afterglows, (iii) the gamma-ray burst-supernova connection, and (iv) the relation between X-ray flashes, gamma-ray bursts, and supernovae

  15. Synthesis of gold nano particles with enlargement size by gamma Co-60 irradiation and investigation of anti oxidation effect

    International Nuclear Information System (INIS)

    Nguyen Ngoc Duy; Dang Van Phu; Le Anh Quoc; Nguyen Quoc Hien

    2014-01-01

    Gold nanoparticles (AuNPs) with size in the range of 10-53 nm were synthesized by gamma Co-60 irradiation using water-soluble chitosan (WSC) as stabilizer and size enlargement by seed approach. Absorption wavelength (λ max ) was measured by UV-Vis spectroscopy and particle size was determined from TEM images. Results showed that value of λ max increased from 523 nm (seed particles) to 525, 537 and 549 nm and the size of AuNPs increased from 10 nm (seed particles) to 20, 38 and 53 nm, respectively, for concentration ratio of Au 3+ /Au 0 (seed) of 2.5, 5 and 10. Antioxidant effect of AuNPs with size of 10, 20, 38 and 53 nm was investigated using free radical 2, 2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) (ABTS .+ ). Results indicated that the smaller the particle size was (10 nm) the stronger the antioxidant effect attained. Thus, AuNPs/WSC synthesis by gamma Co-60 irradiation are promising for applications as antioxidants in cosmetics and in other fields as well. (author)

  16. The Gamma-ray Universe through Fermi

    Science.gov (United States)

    Thompson, David J.

    2012-01-01

    Gamma rays, the most powerful form of light, reveal extreme conditions in the Universe. The Fermi Gamma-ray Space Telescope and its smaller cousin AGILE have been exploring the gamma-ray sky for several years, enabling a search for powerful transients like gamma-ray bursts, novae, solar flares, and flaring active galactic nuclei, as well as long-term studies including pulsars, binary systems, supernova remnants, and searches for predicted sources of gamma rays such as dark matter annihilation. Some results include a stringent limit on Lorentz invariance derived from a gamma-ray burst, unexpected gamma-ray variability from the Crab Nebula, a huge ga.nuna-ray structure associated with the center of our galaxy, surprising behavior from some gamma-ray binary systems, and a possible constraint on some WIMP models for dark matter.

  17. The resistance changes of carbon and metal oxide film resistors by irradiation of 60Co γ rays

    International Nuclear Information System (INIS)

    Okamoto, Shinichi; Fujino, Takahiro; Furuta, Junichiro; Yoshida, Toshio

    1979-01-01

    The resistance changes of glass-sealed deposited-carbon-film and carbon-coated-film resitors and metal oxide glazed resistors made in USA were studied by gamma-ray irradiation. (1) The resistances of deposited-carbon-film resistors of 50, 100 and 200 megohm did not change by irradiation of gamma rays up to 1.9 x 10 9 R. (2) The carbon-coated-film resistors of 100, 1000, 10000 and 100000 megohm had negative resistance changes by irradiation of gamma rays up to 9.9 x 10 8 R. (3) The resistances of metal oxide glazed resistors of 100, 1000 and 10000 megohm did not change by irradiation of gamma rays up to 8.8 x 10 8 R. When radiation monitoring instruments with hi-meg resistors are used in a gamma field with high intensity, the resistors must not be exposed to gamma rays with high doses, or the resistors which do not change by gamma-ray irradiation must be selected. (author)

  18. Status of development of the Gamma Ray Energy Tracking Array (GRETA)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, I.Y.; Schmid, G.J.; Vetter, K. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1996-12-31

    The current generation of large gamma-ray detector arrays, Gammasphere, Eurogam and GASP, are based on modules of Compton suppressed Ge detectors. Due to the solid angle occupied by the Compton shields and to gamma rays escaping the detector, the total peak efficiency of such a design is limited to about 20% for a 1.3 MeV gamma ray. A shell consisting of closely packed Ge detectors has been suggested as the solution to the efficiency limitation. In this case, the entire solid angle is covered by Ge detectors, and by adding the signal from neighboring detectors, the escaped energy is recovered and much higher efficiency can be achieved (e.g. 60% for a 1.3 MeV gamma ray). However, for high multiplicity cascades, the summing of two gamma rays hitting neighboring detectors reduces the efficiency and increases the background. In order to reduce this summing, a large number of detectors is required. For example, with a multiplicity of 25, one needs about 1500 detectors to keep the probability of false summing below 10% and the cost of such a detector array will be prohibitive. Rather than such an approach, the authors are developing a new concept for a gamma-ray array; a shell of closely-packed Ge detectors consisting of 100-200 highly-segmented elements. The high granularity of the segmented Ge detector enables the authors to resolve each of the scattering interactions and determine its position and energy. A tracking algorithm, using the position and energy information, will then identify the interactions belonging to a particular gamma ray and its energy is obtained by summing only these interactions. Such an array can reach a total efficiency about 60%, with a resolving power 1000 times higher than that of current arrays.

  19. On the Preparation of Working Standards for Gamma-Ray Spectrometry

    International Nuclear Information System (INIS)

    Durasevic, M.; Kandic, A.; Milosevic, Z.; Seslak, B.; Vukanac, I.

    2013-01-01

    In the Laboratory for Radionuclide Metrology at Vinca Institute, activity concentration measurements are routinely performed and numerous calibration standards are required. Thus, a variety of calibration standards whose measurement geometry and chemical composition and density are similar to those of the measured samples were prepared. The standardized solutions of a common mixture of gamma-emitting radionuclides (241Am, 109Cd, 139Ce, 57Co, 60Co,137Cs, 203Hg, 113Sn, 85Sr, 88Y and 210Pb) purchased at the Czech Metrological Institute were used to prepare working standards for efficiency and energy calibration of gamma-ray semiconductor HPGe spectrometer in accordance with the IAEA recommendations. Calibration standards were prepared in different geometries (PVC cylindrical boxes, Marinelly beakers and PVC cylindrical bottles) and with various matrices (mineralized grass, activated carbon, surface soil, water, sand and ached filter paper). The matrix materials were spiked by using the activated carbon as the activity carrier, and homogenized mechanically. A comprehensive review of the procedures and techniques used for working standard preparation is presented in this paper.(author)

  20. Influence of source configuration on spectral composition of gamma-ray beams from 60Co teletherapy units

    International Nuclear Information System (INIS)

    Ehrlich, M.; Soares, C.G.; Jackson, B.; Lanoue, P.

    1978-01-01

    Measurements were made of the photon spectra of simulated 60 Co teletherapy beams. Various source configurations and source environments of practical interest were employed for this purpose. The sources consisted of activated cobalt pellets packed into steel capsules. Several combinations of capsule diameters and heights of pellet layers were used. The spacer materials filling the remaining capsule volume were chosen to be of high, intermediate, or low atomic number. The capsules could be inserted, one at a time, into a compartment of either tungsten or brass, simulating the central section of popular commercial 60 Co teletherapy units. There also was some choice in the atomic number of the structural elements holding the capsules in place in the compartment. The largest contribution of scattered photons was found to occur when the materials close to the source pellets had atomic numbers in the vicinity of 30. (author)

  1. Effects of 60Co γ-rays irradiation on seed growth of ground-cover chrysanthemum

    International Nuclear Information System (INIS)

    Ge Weiya; Wang Tiantian; Yang Shuhua; Zhao Ying; Ge Hong; Chen Lin

    2011-01-01

    The seeds of ground-cover chrysanthemum were used to study the effects of different doses of 60 Co γ-rays irradiation(10-50 Gy) on seed germination and physiological characteristics. The results showed that the rate of seed germination and seedling survival decreased significantly with the irradiation doses. With the increase of irradiation dose to above 20 Gy, the content of malondialdehyde (MDA) and activity of peroxidase (POD) in seedlings significantly increased. The similar trends were found in the activities of superoxide dismutase (SOD) and glutathione reductase (GR). Catalase (CAT) activity increased at doses lower than 20 Gy, and then decreased at the higher doses, whereas ascorbate peroxidase (APX) activity did not alter except for 40 Gy. It is concluded that the suitable irradiation dose of mutation breeding is 20 Gy for the seeds of ground-cover chrysanthemum. Although 60 Co γ-rays irradiation resulted in damage of membrane lipid peroxidation in the survival seedlings, the increased activity of CAT and POD could protect them against the damage. (authors)

  2. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni Andreas

    2010-01-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5 th leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  3. Thermal, tensile and rheological properties of low density polyethylene (LDPE) processed irradiated by gamma-ray

    International Nuclear Information System (INIS)

    Ferreto, Helio F.R.; Oliveira, Ana C.F. de; Parra, Duclerc F.; Lugao, Ademar B.

    2013-01-01

    The aim of this paper is to investigate structural changes of low density polyethylene (LDPE) modified by ionizing radiation (gamma rays). The gamma radiation process for modification of commercial polymers is a widely applied technique to promote new physical-chemical and mechanical properties. Gamma irradiation originates free radicals which can induce chain scission or recombination, providing its annihilation, branching or crosslinking. The samples were prepare in hydraulic press in temperature 180 deg C after was irradiated with gamma source of 60 Co at doses of 5, 10, 20, 50 or 100 kGy at a dose rate of 5 kGy/h in inert atmosphere. The changes in molecular structure of LDPE, after gamma irradiations were evaluated using thermogravimetric analysis (TGA) and tensile machine and oscillatory rheology. The results showed the variations of the properties depending on the dose at each atmosphere. (author)

  4. Effect of low-dose 60Co gamma irradiation on the photosynthetic activity of maize seedlings

    International Nuclear Information System (INIS)

    Turcsanyi, G.

    1979-01-01

    Photosynthesis investigations were carried out on maize seedlings treated with 1000 rad of 60 Co gamma irradiation prior to sowing. The aim of the work was to find out, to what degree the individual processes of photosynthesis are affected by small doses of irradiation. The increase in weight, the chlorophyll a, chlorophyll b and carotinoid content as well as the photosynthetic O 2 -evolution and 14 CO 2 -fixation of the seedlings were measured. The results indicate that, in contradiction to the data given in the literature, the occasional increase in weight caused by small-dose irradiation is not in connection with the membrane-bound part of the photosynthetic apparatus, but it is the consequence of the increased activity of the Calvin-cycle enzymes in the stroma of the chloroplasts. (author)

  5. Effect of cobalt-60 gamma-ray irradiation on beans (Phaseolus vulgaris L.) of huasteco variety

    International Nuclear Information System (INIS)

    Navarro A, W.

    1984-01-01

    Bean seeds, Huasteco variety, were irradiated at 10, 20, 30 and 40 kR in a cobalt-60 gamma-ray source. Non-irradiated seeds were used as control. Irradiated and non-irradiated seeds were planted under greenhouse conditions using a random design and a population of 200 plants per treatment for both first and second generations (M 1 and M 2 ). The characters studied were; germination, survival, morphological changes of leaves and stem, change in seed coat colour, flowering, height, stem diameter, number of internodes, number of pods and number of seeds per pod. General plant behaviour was also observed to detect changes on a genic or chromosomic level. (M.A.C.) [pt

  6. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  7. Effects of "6"0Corays seed irradiation on the germination characteristic and flowering traits of Clivia miniata

    International Nuclear Information System (INIS)

    Bao Jianzhong; Li Fengtong; Sun Ye; Liu Chungui; Ma Hui; Zhang Tian; Chen Xiulan

    2013-01-01

    Seeds of 6 cultivars of Clivia miniata were irradiated under different irradation doses, 0, 2, 4, 6, and 8 Gy of "6"0Corays to investigate the effects on the germination characteristic and flowering traits. Results indicated that the seeds of Clivia miniata were sensitive to the irradiation of "6"0Corays and the germination characteristic could be affected by low dosage. The half lethal dosage of 'Gefulan' and 'Foguang' was 2-4 Gy, and 4-6 Gy in other 4 cultivars, respectively. The higher dosages, the higher variation rate below 6 Gy. Significant impacts were observed on delaying flowering, reducing peduncle height and reducing inflorescence diameter by the irradiation treatment at each dosage. However, the number of floret was not obviously affected. In conclusion, 4 Gy was considered the most favorable dosage afte treatment of "6"0Corays irradiation on the seeds of Clivia miniata, which was able to guarantee a high seed germination rate and a high variation rate, so as to screen new germplasm more effectively. (authors)

  8. Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Allisy-Roberts, P.J.; Kessler, C.; Burns, D.T. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Berlyand, V.; Berlyand, A. [All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements, Moscow (Russian Federation)

    2010-02-15

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radio-technical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in {sup 60}Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. (authors)

  9. Compton Gamma-Ray Observatory

    Science.gov (United States)

    1991-01-01

    This photograph shows the Compton Gamma-Ray Observatory (GRO) being deployed by the Remote Manipulator System (RMS) arm aboard the Space Shuttle Atlantis during the STS-37 mission in April 1991. The GRO reentered Earth atmosphere and ended its successful mission in June 2000. For nearly 9 years, the GRO Burst and Transient Source Experiment (BATSE), designed and built by the Marshall Space Flight Center (MSFC), kept an unblinking watch on the universe to alert scientists to the invisible, mysterious gamma-ray bursts that had puzzled them for decades. By studying gamma-rays from objects like black holes, pulsars, quasars, neutron stars, and other exotic objects, scientists could discover clues to the birth, evolution, and death of stars, galaxies, and the universe. The gamma-ray instrument was one of four major science instruments aboard the Compton. It consisted of eight detectors, or modules, located at each corner of the rectangular satellite to simultaneously scan the entire universe for bursts of gamma-rays ranging in duration from fractions of a second to minutes. In January 1999, the instrument, via the Internet, cued a computer-controlled telescope at Las Alamos National Laboratory in Los Alamos, New Mexico, within 20 seconds of registering a burst. With this capability, the gamma-ray experiment came to serve as a gamma-ray burst alert for the Hubble Space Telescope, the Chandra X-Ray Observatory, and major gound-based observatories around the world. Thirty-seven universities, observatories, and NASA centers in 19 states, and 11 more institutions in Europe and Russia, participated in the BATSE science program.

  10. X-Ray-Driven Gamma Emission

    International Nuclear Information System (INIS)

    Carroll, J. J.; Karamian, S. A.; Rivlin, L. A.; Zadernovsky, A. A.

    2001-01-01

    X-ray-driven gamma emission describes processes that may release nuclear energy in a 'clean' way, as bursts of incoherent or coherent gamma rays without the production of radioactive by-products. Over the past decade, studies in this area, as a part of the larger field of quantum nucleonics, have gained tremendous momentum. Since 1987 it has been established that photons could trigger gamma emission from a long-lived metastable nuclear excited state of one nuclide and it appears likely that triggering in other isotopes will be demonstrated conclusively in the near future. With these experimental results have come new proposals for the creation of collective and avalanche-like incoherent gamma-ray bursts and even for the ultimate light source, a gamma-ray laser. Obviously, many applications would benefit from controlled bursts of gamma radiation, whether coherent or not. This paper reviews the experimental results and concepts for the production of gamma rays, driven by externally produced X-rays

  11. Thermoluminescence response of K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3} nanophosphor Co-doped with Eu and Ce for gamma ray dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Patil, B. J. [Dept. of Physics, Abasaheb Garware College, Pune-411004 (India); Bhadane, Mahesh S.; Dahiwale, S. S.; Bhoraskar, V. N.; Dhole, S. D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India); Mandlik, N. T. [Dept. of Physics, Fergusson College, Pune-411004 (India); Kulkarni, M. S. [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Bhatt, B. C. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2015-06-24

    K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3} nanophosphors co-doped with Eu and Ce were synthesized by the chemical co-precipitation method. These samples were further annealed at 700 °C structural reformation. The structural and morphological characteristics were studied using XRD and TEM techniques. The particle size calculated from XRD spectra was around 35 nm. The as synthesized sample shows cubic structure annealed at 700 °C. The as synthesized and annealed sample of K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}: EuCe were irradiated with Co{sup 60} gamma rays for the doses from 2Gy to 1kGy. The TL characteristic sample of co-doped were studied for the dosimetric application by gamma radiation. The TL spectrum of annealed sample has single peaked at 160 °C. The Eu doped sample has a high TL sensitivity than Ce doped sample. But after co-doping with Eu and Ce, TL intensity observed to be decreased. The decrees in TL peak intensity of the phosphor on co-doping of Eu and Ce gives an insight into the emission mechanism of the phosphor which involves energy transfer from Eu to Ce. The TL response of all the samples were found to be linear for the dose from 2 Gy to 1 KGy. Therefore, K{sub 2}Ca{sub 2}(SO{sub 4}){sub 3}: EuCe nanophosphor can be used for the measurement of high dose of gamma radiation.

  12. DOMI: mutant of tomato of double purpose obtained by means of the induction of mutations with rays gamma of 60Co

    International Nuclear Information System (INIS)

    Gonzalez, Maria C; Mukandama, JP; Ali, MM; Trujillo Delfina

    2010-01-01

    DOMI is a tomato mutant obtained at the National Institute of Agricultural Sciences (INCA) after irradiating seeds from Amalia variety with 500 Gy gamma rays. This variety has a high productive potential and an appropriate quality for fresh consumption and industrial purposes

  13. Extragalactic Gamma-Ray Astrophysics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    During the last decades, various classes of radio-loud active galactic nuclei have been established as sources of high-energy radiation extending over a very broad range from soft gamma-rays (photon energies E~MeV) up to very-high-energy gamma-rays (E>100 GeV). These include blazars of different types, as well as young and evolved radio galaxies. The observed gamma-ray emission from such implies efficient particle acceleration processes taking place in highly magnetized and relativistic jets produced by supermassive black holes, processes that have yet to be identified and properly understood. In addition, nearby starforming and starburst galaxies, some of which host radio-quiet Seyfert-type nuclei, have been detected in the gamma-ray range as well. In their cases, the observed gamma-ray emission is due to non-thermal activity in the interstellar medium, possibly including also a contribution from accretion disks and nuclear outflows. Finally, the high-energy emission from clusters of galaxies remains elusive...

  14. Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

    Science.gov (United States)

    Shridhar, Ravi; Estabrook, William; Yudelev, Mark; Rakowski, Joseph; Burmeister, Jay; Wilson, George D; Joiner, Michael C

    2010-03-01

    Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

  15. Prospecting effect of the combined gamma-ray survey in the hydrochemical reconnaissance

    International Nuclear Information System (INIS)

    Hu Zheng'an.

    1991-01-01

    Gamma-ray survey is characterized by economies, rapidness, portability and continuous measurement in uranium reconnaissance. Combined gamma-ray survey can be conducted in hydrochemical reconnaissance with less investment and faster results, and prospects for detailed prospecting and exposing can be directly found by the survey. The arrangements in the field operation is suited to hydrochemical reconnaissance. By working for one time two sets of data with different characteristics could be obtained. In data interpretation and application, both data can be mutually complementary. It is a blank area for the non-water section in hydrochemical reconnaissance in which gamma-ray survey can be supplemented. Gamma-ray survey can provide data for the interpretation of hydrochemical anomalies and the size and concentration of hydrochemical anomalies are the basis for the inference of the mineralization at depth. The statistical results confirm that as compared with the conventional gamma-ray survey (at 1:10000 scale), the discovery rate of anomalies from the combined gamma-ray survey (at 1: 25000 scale) may reach 60%. It is thus that the data from the combined gamma-ray survey can be applied by lowering one grade in measurement accuracy which can meet the demand for accuracy

  16. Gravitational Waves versus X and Gamma Ray Emission in a Short Gamma-Ray Burst

    OpenAIRE

    Oliveira, F. G.; Rueda, Jorge A.; Ruffini, Remo

    2012-01-01

    The recent progress in the understanding the physical nature of neutron star equilibrium configurations and the first observational evidence of a genuinely short gamma-ray burst, GRB 090227B, allows to give an estimate of the gravitational waves versus the X and Gamma-ray emission in a short gamma-ray burst.

  17. Gamma-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1980-01-01

    Results are presented from an analysis of the celestial gamma-ray fine-scale structure based on over half of the data which may ultimately be available from the COS-B satellite. A catalogue consisting of 25 gamma-ray sources measured at energies above 100 MeV is presented. (Auth.)

  18. Use of {sup 60}Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A., E-mail: santosghf@hotmail.com, E-mail: edvborges@yahoo.com, E-mail: amdemelo@hotmail.com, E-mail: claudia.salima@gmail.com, E-mail: ricardo.yara@gmail.com, E-mail: tadeu1903@yahoo.com.br, E-mail: elba@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2013-07-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from {sup 60}Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from {sup 60}Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  19. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  20. Dose Rate and Mass Attenuation Coefficients of Gamma Ray for Concretes

    CERN Document Server

    Abdel-Latif, A A; Kansouh, W A; El-Sayed, F H

    2003-01-01

    This work is concerned with the study of the leakage gamma ray dose and mass attenuation coefficients for ordinary, basalt and dolomite concretes made from local ores. Concretes under investigation were constructed from gravel, basalt and dolomite ores, and then reconstructed with the addition of 3% steel fibers by weight. Measurements were carried out using a collimated beam from sup 6 sup 0 Co gamma ray source and sodium iodide (3x3) crystal with the genie 2000 gamma spectrometer. The obtained fluxes were transformed to gamma ray doses and displayed in the form of gamma ray dose rates distribution. The displayed curves were used to estimate the linear attenuation coefficients (mu), the relaxation lengths (lambda), half value layer (t sub 1 /2) and tenth value layer (t sub 1 /10). Also, The total mass attenuation coefficients of gamma ray have been calculated to the concerned concretes using XCOM (version 3.1) program and database elements cross sections from Z=1 to 100 at energies from 10 keV to 100 MeV. In...

  1. Biochemical and pharmacological studies of native and irradiated crotamine with gamma radiation of 60Co

    International Nuclear Information System (INIS)

    Mitake, Malvina Boni

    2000-01-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide from the South American rattlesnake venom, composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of this thesis was carry out biochemical and pharmacological studies of native and irradiated crotamine with 60 Co. Crotamine was purified from Crotalus durissus terrificus venom by Sephadex G-100 gel filtration followed by ion exchange chromatography, using a Fast Performance Liquid Chromatography (FPLC) system. It was irradiated at 2 mg/ml in 0.15 M Na Cl with 2.0 kGy gamma radiation emitted by a 60 Co source. The native and irradiated crotamine were evaluated by biochemical characterization, toxic activity (LD 50 and biodistribution. The native and irradiated crotamine were labelled with 29.6 MBq of 125 I using chloramine T method, and separated in a Sephadex G-50 column. Male Swiss mice (35± 5 g), were injected i.p. with o.1 mL (2.4 x 10 6 cpm/mouse) of 125 I native crotamine or with 0.4 mL (1.3 x 10 6 cpm/mouse) of 125 I irradiated crotamine. At 0.08; 0.25; 0.5; 1; 2; 4; 8; 12 and 24 hours the animal were killed by ether inhalation. Blood, spleen, liver, kidneys, brain, lungs, heart, and skeletal muscle were collected in order to determine radioactivity content. The results showed that gamma radiation did not change the protein concentration, the electroforetic profile or the primary structure of the protein, although differences were shown by spectroscopic techniques. The gamma radiation diminished the toxicity of crotamine, but it did not abolish bioactivity. Biodistribution studies showed that native and irradiated crotamine have hepatic metabolism and renal elimination. The native and irradiated crotamine have affinity by skeletal muscle and they did not pass the blood - brain

  2. Crystal glass and barite used for x ray and gamma radiation shielding

    International Nuclear Information System (INIS)

    Antonio Filho, Joao

    2008-01-01

    Full text: Crystal glass, barite plaster and barite concrete has been widely used as shielding material in gamma radiation sources as well as x-ray generating equipment to replace the plumbiferous glass and in the wall covering, in order to minimize exposure to individuals. However, properties of the radiation attenuation of crystal glass commercially available in Brazil, for the different types of energy are not known. For this reason, this work was carried out aiming to determine the radiation attenuation, transmission curves and Half Value Layer. In this work, ten plates of crystal glass, with dimensions of 20 cm x 20 cm and range of thicknesses from 0.5 to 2.0 cm, and ten plates of barite plaster and five plates of barite concrete, with dimensions of 20 x 20 cm 2 and range of thicknesses from 1,0 to 5,0 cm, were used. The plates were X-ray irradiated with potential constants of 60, 80, 110, 150 kV and gamma radiation of 60 Co. Analysis in the properties of the 60 Co radiation attenuation of barite plaster and barite concrete commercially available in Brazil were also carried out. The curves of attenuation and of transmission were obtained for crystal glass, barite plaster and barite concrete (mGy/m A.min) at 1 meter as a function of thickness. The thickness equivalent of a half value layer and deci value layer of crystal glass for all types of radiation and energies studied was also determined. Although their use permits the dimensioning of the armor covering for external x-radiation whit precision and safety without elevating the cost of protection. (author)

  3. Gamma-ray burst polarimeter (GAP)

    International Nuclear Information System (INIS)

    Mihara, Tatehiro; Murakami, Toshio; Yonetoku, Daisuke; Gunji, Shuichi; Kubo, Shin

    2013-01-01

    The gamma-ray burst polarimeter (GAP: GAmma-ray burst Polarimeter), which had been almost handcrafted by scientists, has succeeded in working normally in interplanetary space, and in detecting the polarization of the gamma-ray from a mysterious astronomical object 'gamma-ray burst'. It is the first result of the detectors in the world exclusively aiming at detecting gamma-ray polarization. We mainly describe the hardware of our GAP equipment and show the method of preparing equipment to work in the cosmic space with a tight budget. The mechanical structure, the electronic circuits, the software on the equipment, the data analysis on the earth, and the scientific results gained by the observation just over one year, are presented after explaining the principle of gamma-ray polarization detection. Our design to protect equipment against mechanical shock and cosmic radiation may provide useful information for future preparation of compact satellite. (J.P.N.)

  4. The development of 60Co γ knife therapy sources

    International Nuclear Information System (INIS)

    Wu Rihua; Li Xingyi; Wu Guihua; Xia Bing; Zhang Jirong; Chen Tieguang

    2001-01-01

    60 Co γ gamma knife source is a kernel unit of γ knife therapy equipment. It has small active core, high specific activity, narrow half dark area, best focus form, long use period. The research of 60 Co γ knife sources are presented. Specifications of γ knife sources, technical parameters, safety performance, structure feature, procedure and quality control during research are discussed. 60 Co γ source consists of high specific activity cobalt pellets and double stainless steel sealed by argon arc welding. Its safety performance, surface contamination and leakage testing meet the requirements of GB 4075 and GB 4076

  5. Imaging phase holdup distribution of three phase flow systems using dual source gamma ray tomography

    International Nuclear Information System (INIS)

    Varma, Rajneesh; Al-Dahhan, Muthanna; O'Sullivan, Joseph

    2008-01-01

    Full text: Multiphase reaction and process systems are used in abundance in the chemical and biochemical industry. Tomography has been successfully employed to visualize the hydrodynamics of multiphase systems. Most of the tomography methods (gamma ray, x-ray and electrical capacitance and resistance) have been successfully implemented for two phase dynamic systems. However, a significant number of chemical and biochemical systems consists of dynamic three phases. Research effort directed towards the development of tomography techniques to image such dynamic system has met with partial successes for specific systems with applicability to limited operating conditions. A dual source tomography scanner has been developed that uses the 661 keV and 1332 keV photo peaks from the 137 Cs and 60 Co for imaging three phase systems. A new approach has been developed and applied that uses the polyenergetic Alternating Minimization (A-M) algorithm, developed by O'Sullivan and Benac (2007), for imaging the holdup distribution in three phases' dynamic systems. The new approach avoids the traditional post image processing approach used to determine the holdup distribution where the attenuation images of the mixed flow obtained from gamma ray photons of two different energies are used to determine the holdup of three phases. In this approach the holdup images are directly reconstructed from the gamma ray transmission data. The dual source gamma ray tomography scanner and the algorithm were validated using a three phase phantom. Based in the validation, three phase holdup studies we carried out in slurry bubble column containing gas liquid and solid phases in a dynamic state using the dual energy gamma ray tomography. The key results of the holdup distribution studies in the slurry bubble column along with the validation of the dual source gamma ray tomography system would be presented and discussed

  6. Morphological and histological studies on freshwater prawn Macrobrachium rosenbergii (de man) irradiated with (60)Co gamma radiation.

    Science.gov (United States)

    Stalin, A; Broos, K V; Sadiq Bukhari, A; Syed Mohamed, H E; Singhal, R K; Venu-Babu, P

    2013-11-15

    This study was framed to investigate the (60)Co gamma radiation induced morphological and histological variations in freshwater prawn Macrobrachium rosenbergii. The LD50 value of (60)Co gamma irradiated M. rosenbergii observed (by probit analysis) at 30 Gy. Prawns were irradiated to four different dose levels (3 mGy, 30 mGy, 300 mGy and 3,000 mGy) using Theratron Phoenix TeleCobalt Unit [P-33] and one control group (without irradiation) maintained separately. Irradiated groups exhibited several morphological variations such as discoloration; damaged rostrum; opaque coloration in cephalothorax; black bands and dot formation in abdomen; deformed uropods and telson in tail regions when compared with control group. The Hepato Somatic Index reflected the severity of radiation on hepatopancreas. Histological variations in gills, hepatopancreas and muscles of irradiated groups were observed. In gills, structural changes such as swollen and fused lamellae, abnormal gill tips, hyperplasic, necrotic and clavate-globate lamellae were observed in gamma irradiated prawns. Accumulation of hemocytes in hemocoelic space, interstitial sinuses filled with abnormal infiltrated hemocytes, the tubular epithelium with ruptured basal laminae, abnormal and coagulated lumen, necrotic tubules, thickened basal laminae, tissue debris, necrotic hepatocytes were observed in irradiated prawn hepatopancreas. In muscle, shrinkage of muscular fiber and necrotic musculature were observed in irradiated prawns. These structural alterations of the organs it is felt could affect the vital physiological functions such as respiration, osmotic and ionic regulation in gills and muscles; absorption, storage and secretion of the hepatopancreas which in turn could adversely affect the growth and survival of freshwater prawn M. rosenbergii. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Hillier, R.

    1984-01-01

    The book reviews the development of gamma ray astronomy over the past twenty five years. A large section of the book is devoted to the problems of background radiation and the design of detectors. Gamma rays from the sun, the galactic disc, the galaxy, and extra galactic sources; are also discussed. (U.K.)

  8. Effect of intermediate zone during gamma-gamma and X-ray spectrum logging of quarry wells with inversive probes

    International Nuclear Information System (INIS)

    Artsybashev, V.A.; Volkov, A.A.

    1981-01-01

    Experimental and calculated data on the effect of intermediate zone on results of gamma-gamma and X-ray spectrum logging of quarry wells at chalcopyrite deposits are presented. The measurements have been carried out using 57 Co and 109 Cd sources for intermediate zone represented by water, air and mud. Requirements for technical conditions of wells have been formulated. According to the requirements the application of gamma- gamma method is possible when the thickness of the intermediate zone does not exceed several millimetres and that of X-ray spectrum method - when the thickness does not exceed several hundredths of a millimetre [ru

  9. Real-time airborne gamma-ray background estimation using NASVD with MLE and radiation transport for calibration

    Energy Technology Data Exchange (ETDEWEB)

    Kulisek, J.A., E-mail: Jonathan.Kulisek@pnnl.gov; Schweppe, J.E.; Stave, S.C.; Bernacki, B.E.; Jordan, D.V.; Stewart, T.N.; Seifert, C.E.; Kernan, W.J.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this challenge, we have developed a new technique for real-time estimation of background gamma radiation from aerial measurements without the need for human analyst intervention. The method can be calibrated using radiation transport simulations along with data from previous flights over areas for which the isotopic composition need not be known. Over the examined measured and simulated data sets, the method generated accurate background estimates even in the presence of a strong, {sup 60}Co source. The potential to track large and abrupt changes in background spectral shape and magnitude was demonstrated. The method can be implemented fairly easily in most modern computing languages and environments.

  10. Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999.

    Science.gov (United States)

    Gasparro, J; Hult, M; Komura, K; Arnold, D; Holmes, L; Johnston, P N; Laubenstein, M; Neumaier, S; Reyss, J-L; Schillebeeckx, P; Tagziria, H; Van Britsom, G; Vasselli, R

    2004-01-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes gamma-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring (60)Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from (60)Co activity is in agreement with previous measurements using the short-lived radionuclides (51)Cr and (59)Fe. Limits on contamination of the samples with (60)Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using (60)Co activation.

  11. Effect of the irradiation on Salmonella enteretidis var. typhimurium with gamma rays from 60Co

    International Nuclear Information System (INIS)

    Maliska, C.; Norberg, A.N.; Norberg, J.B.M.; Santos Souza, R.C. dos; Silva Tavares, P.R. da

    1988-01-01

    The use of ionizinf radiation to the destruction of microrganisms responsible for food deterioration, and productive of feeding toxinfections constitute their usefulness for actually peaceful goals of nuclear energy. The feeding toxinfections are, among us, produced in their most part by Salmonella enteritidis var. typhimurim. One hundred nineteen samples of milk containing about 150.000 bacteria per ml, by means doses ranging from 100 to 1.100 gy, two samples of surviving bacteria were again irradiated by doses up to 2.5000 Gy. The bacteria not previously irradiated were throughly killed by means of doses of 1.100 Gy. Salmonella enteritidis var. typhimurium was inactivated by means of 1.200 and 1.900 Gy doses. It was concluded that 60-Cobalt gamma radiation minimal lethal dose to Salmonella enteritidis var. typhimurium is 1.200 Gy; the re-irradiation to the survivors prompts the forthcoming of more resistant germs. (author) [pt

  12. Programs and procedures for assessing quality of spectral gamma-ray borehole data for the UGTA

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1998-01-01

    This report describes the procedures and computer programs used to process spectral gamma-ray borehole logging data in the UGTA (UnderGround Test Area) program at the NTS (Nevada Test Site) to assess data quality. These programs and procedures were used to analyze data from five boreholes in the UGTA program. Development of these computer programs and procedures required considerable effort and the primary purpose of this report is to provide continuity with future activities related to spectral gamma-ray borehole logging in the UGTA program. This is especially important because of the long time interval between cessation of logging in April, 1996 and the next round of activity, which has not yet occurred. This report should also be useful if any quality control issues arise regarding past or forthcoming spectral gamma-ray log analyses. In the characterization work underway at the Nevada Test Site Underground Test Area, the logging contractor, Western Atlas, agreed to identify five artificial nuclides based on their gamma-ray signatures. Those nuclides are 60 Co, 106 Ru, 125 Sb, 134 Cs, and 137 Cs. In the case of 106 Ru, which is not a gamma emitter, any detected gamma rays come from the daughter nuclide 106 Rh which has a half-life of 30 s. With such a short half-life, 106 Rh can be considered to be in equilibrium with 106 Ru under most conditions so the result is the same as if the gamma rays were emitted by the 106 Ru. The Western Atlas spectral gamma-ray curve plots from a given borehole present detailed qualitative information on the apparent distribution of natural and artificial nuclides with depth in the borehole. The computer programs and procedures described in this report were used to provide a quality analysis of the contractor's processed data and to work with the contractor to validate and/or refine their existing automatic processing. This was done using a procedure that was developed and tested successfully in earlier work at the NTS; the revised

  13. Space instrumentation for gamma-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Teegarden, B.J

    1999-02-11

    The decade of the 1990s has witnessed a renaissance in the field of gamma-ray astronomy. The seminal event was the launch of the Compton Gamma-Ray Observatory (CGRO) in April 1991. There have been a flood of major discoveries from CGRO including breakthroughs in gamma-ray bursts, annihilation radiation, and blazars. The Italian SAX satellite was launched in April 1996. Although not primarily a gamma-ray mission, it has added a new dimension to our understanding of gamma-ray bursts. Along with these new discoveries a firm groundwork has been laid for missions and new technology development that should maintain a healthy and vigorous field throughout most of the next decade. These include the ESA INTEGRAL mission (INTErnational Gamma-Ray Astrophysics Laboratory, to be launched in mid-2001) and the NASA GLAST mission (Gamma-Ray Large Area Space Telescope) with a likely launch in the middle of the next decade. These two missions will extend the observational capabilities well beyond those of CGRO. New technologies (to gamma-ray astronomy), such as cooled germanium detectors, silicon strip detectors, and CdTe detectors are planned for these new missions. Additional promising new technologies such as CdZnTe strip detectors, scintillator fibers, and a gamma-ray lens for future gamma-ray astronomy missions are under development in laboratories around the world.

  14. Space instrumentation for gamma-ray astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.

    1999-01-01

    The decade of the 1990s has witnessed a renaissance in the field of gamma-ray astronomy. The seminal event was the launch of the Compton Gamma-Ray Observatory (CGRO) in April 1991. There have been a flood of major discoveries from CGRO including breakthroughs in gamma-ray bursts, annihilation radiation, and blazars. The Italian SAX satellite was launched in April 1996. Although not primarily a gamma-ray mission, it has added a new dimension to our understanding of gamma-ray bursts. Along with these new discoveries a firm groundwork has been laid for missions and new technology development that should maintain a healthy and vigorous field throughout most of the next decade. These include the ESA INTEGRAL mission (INTErnational Gamma-Ray Astrophysics Laboratory, to be launched in mid-2001) and the NASA GLAST mission (Gamma-Ray Large Area Space Telescope) with a likely launch in the middle of the next decade. These two missions will extend the observational capabilities well beyond those of CGRO. New technologies (to gamma-ray astronomy), such as cooled germanium detectors, silicon strip detectors, and CdTe detectors are planned for these new missions. Additional promising new technologies such as CdZnTe strip detectors, scintillator fibers, and a gamma-ray lens for future gamma-ray astronomy missions are under development in laboratories around the world

  15. Microstructural characterization of industrial foams by gamma ray transmission and X-ray microtomography

    International Nuclear Information System (INIS)

    Rodrigues, Luiz Eduardo

    2004-01-01

    This work presents the total porosity measurements of the aluminum and silicon carbide (SiC) foams samples. For porosity determination the gamma ray transmission and X-ray microtomography with conic beam techniques were used. These methods have more advantage than conventional ones, because they are non destructive and provide more details of the analyzed material porous structure. The aluminum foam samples with 10, 20, 30, 40 and 45 ppi (pores per inch) and SiC ceramic foam samples with 20, 30, 45, 60, 75, 80 and 90 ppi were analysed by gamma transmission. The SiC 60, 75 and 90 ppi samples were also analyzed by X-ray microtomography. For the gamma ray transmission measurements it was used an 241 Am source (59.53 keV), a NaI(Tl) scintillation detector, collimators, a XYZ micrometric table and standard gamma spectrometry electronics connected to a multichannel analyzer, at the LFNA/UEL. For the X-ray microtomographic measurements, the Fein Focus X-ray system of the Nuclear Instrumentation Laboratory of the COPPE, located at the Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, was used. This equipment provide us images with micrometric resolution (53.48 μm) using a conic X-ray beam and bidimensional detection. The microtomographic images were pre-processed and analyzed by the Imago software, developed at Porous Media and Materials Thermophysical Properties Laboratory (LMPT) of the Mechanical Engineering Department, located at Universidade Federal de Santa Catarina, Florianopolis, SC. Employing the The Imago software it was calculated the total porosity, pore size distribution and autocorrelation function C(u) of the binarized microtomographic images of the each sample. The microtomographic 3-D image of each sample was compared with 3-D image reconstructed by the Gaussian truncated method. This method generates a periodic 3-D porous structure by using of the autocorrelation function of one 2-D cross sectional image of the sample. (author)

  16. Effect of Irradiation of 60CO Gamma Rays on Growth of Garlic (Allium Sativum L) Plants Cv. Lumbu Hijau at Low Land Area

    International Nuclear Information System (INIS)

    Ismiyati Sutarto; Kumala Dewi; Arwin; Nurrohma

    2004-01-01

    Garlic originally come from the sub tropical area. In Indonesia, garlic is grown generally in high land area with an altitude between 1000 - 1600 m above sea level. Therefore, the area for growing and producing garlic is limited. Besides, genetic variation of garlic is very narrow since garlic belongs to vegetatively propagated crops. An effort for increasing genetic variation of garlic was done by exposing garlic cloves to gamma rays in order to obtain garlic mutant lines adapted to low land area. Garlic cloves were exposed to different doses of gamma rays 0 (untreated) 2, 4, 6, 8 and 10 Gy at the Centre for Research and Development of Isotope and Radiation Technology. Each dose consisted of 150 garlic cloves. Untreated and irradiated garlic cloves were grown at Bandar Buat Experimental Station (50 m above sea level), Padang, West Sumatera. The experiment was arranged in a randomized block design with three replication. The parameter observed were percentage of grown plants and survival harvested plants, plant height, leaf number, chlorophyll content, number of stomata, plant age, number of cloves per bulbs, fresh, dry weight and diameter of bulbs. The result indicated that the dose of gamma rays 6 Gy is an advantage dose for obtaining well adapted garlic mutant lines in the low land area. (author)

  17. Results of 1999 Spectral Gamma-Ray and Neutron Moisture Monitoring of Boreholes at Specific Retention Facilities in the 200 East Area, Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    DG Horton; RR Randall

    2000-01-18

    Twenty-eight wells and boreholes in the 200 East Are% Hanford Site, Washington were monitored in 1999. The monitored facilities were past-practice liquid waste disposal facilities and consisted of six cribs and nineteen ''specific retention'' cribs and trenches. Monitoring consisted of spectral gamma-ray and neutron moisture logging. All data are included in Appendix B. The isotopes {sup 137}Cs, {sup 60}Co, {sup 235}U, {sup 238}U, and {sup 154}Eu were identified on spectral gamma logs from boreholes monitoring the PUREX specific retention facilities; the isotopes {sup 137}Cs, {sup 60}Co, {sup 125}Sb, and {sup 154}Eu were identified on the logs from boreholes at the BC Controlled Area cribs and trenches; and {sup 137}Cs, {sup 60}Co, and {sup 125}Sb were, identified on the logs from boreholes at the BX specific retention trenches. Three boreholes in the BC Controlled Area and one at the BX trenches had previous spectral gamma logs available for comparison with 1999 logs. Two of those logs showed that changes in the subsurface distribution of {sup 137}CS and/or {sup 60}Co had occurred since 1992. Although the changes are not great, they do point to continued movement of contaminants in the vadose zone. The logs obtained in 1999 create a larger baseline for comparison with future logs. Numerous historical gross gamma logs exist from most of the boreholes logged. Qualitative comparison of those logs with the 1999 logs show many substantial changes, most of which reflect the decay of deeper short-lived isotopes, such as {sup 106}Ru and {sup 125}Sb, and the much slower decay of shallower and longer-lived isotopes such as {sup 137}Cs. The radionuclides {sup 137}Cs and {sup 60}Co have moved in two boreholes since 1992. Given the amount of movement and the half-lives of the isotopes, it is expected that they will decay to insignificant amounts before reaching groundwater. However, gamma ray logging cannot detect many of the contaminants of interest such

  18. Optimization of foaming properties of sludge protein solution by 60Co γ-ray/H2O2 using response surface methodology

    International Nuclear Information System (INIS)

    Xiang, Yulin; Xiang, Yuxiu; Wang, Lipeng; Zhang, Zhifang

    2016-01-01

    Response surface methodology and Box-Behnken experimental design were used to model and optimize the operational parameters of foaming properties of the sludge protein solution by 60 Co γ-ray/H 2 O 2 treatment. The four variables involved in this research were the protein solution concentration, H 2 O 2 , pH and dose. In the range studied, statistical analysis of the results showed that selected variables had a significant effect on protein foaming properties. The optimized conditions contained: protein solution concentration 26.50% (v/v), H 2 O 2 concentration 0.30% (v/v), pH value 9.0, and dose 4.81 kGy. Under optimal conditions, the foamability and foam stability approached 23.3 cm and 21.3 cm, respectively. Regression analysis with R 2 value of 0.9923 (foamability) and 0.9922 (foam stability) indicated a satisfactory correlation between the experimental data and predicted values (response). In addition, based on a feasibility analysis, the 60 Co γ-ray/H 2 O 2 method can improve odor and color of the protein foaming solution. - Highlights: • Effects of 60 Co γ-ray/H 2 O 2 on foaming properties of sludge protein were studied. • Response surface methodology and Box-Behnken experimental design were applied. • 60 Co γ-ray/H 2 O 2 method can improve foaming properties of protein solution.

  19. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  20. Relative biological effectiveness (RBE) of fission neutrons and gamma rays at occupational exposure levels: Volume 1, Studies on the genetic effects in mice of 60 equal once-weekly exposures to fission neutrons and gamma rays

    International Nuclear Information System (INIS)

    Grahn, D.; Carnes, B.A.

    1987-10-01

    The relative biological effectiveness (RBE) values for low doses of fission neutrons compared to 60 Co gamma rays were determined with four separate assessments of genetic damage induced in young hybrid male mice. Both radiations were delivered at low dose levels over about one-half the adult lifetime as 60 once-weekly exposures. Genetic damage assessed included both transient and residual injury. The latter is more critical, as residual genetic injury can be transmitted to subsequent generations long after the radiation exposures have ceased. Assays were performed periodically during the 60-week exposure period and at 10 or more weeks after the irradiations had terminated. RBE values, with few exceptions, ranged between 5 and 15 for transient injury and between 25 and 50 for different types of residual genetic injury. The most important form of residual genetic damage in this study was the balanced reciprocal chromosome translocation. These translocations continue to be transmitted throughout reproductive life and can lead to reduced fertility and increased prenatal mortality. The best estimate of the RBE value for translocations was 45 +- 10. Implications and recommendations with regard to the neutron quality factor will be presented conjointly with the findings from the data obtained in this same project on life shortening and on the risks of incidence or death from neoplastic disease. 64 refs., 23 tabs

  1. Calculation of reasonable exemption levels for surface contamination by measuring overall gamma ray

    International Nuclear Information System (INIS)

    Ogino, Haruyuki; Hattori, Takatoshi

    2008-01-01

    The present regulation on surface contamination [Bq/cm 2 ] is determined from a simple radiological model for the most hazardous radionuclides (Pu-239 for alpha emitters and Sr-90 for beta emitters) and its extremely conservative model is applied for all other alpha and beta emitters. In this study, reasonable exemption levels for surface contamination are calculated for each radionuclide by adopting an original radiological dose evaluation method for surface contamination that can be applied in radiation safety, transport safety and waste safety. Furthermore, a new concept of judging the exemption by estimating the overall contamination [Bq] on the objects from the measurement of gamma ray has been designed and a reasonable value was derived. We conclude that the overall exemption levels obtained by gamma ray measurement can be one order smaller than those obtained by the conventional method for some radionuclides, such as Mn-54, Co-60, Nb-94, Cs-134, Cs-137, Eu-152 and Eu-154. (author)

  2. Study of uptake and endocytosis of gamma rays-irradiated crotoxin by mice peritoneal macrophages; Avaliacao do mecanismo de captacao e endocitose de crotoxina submetida a acao da radiacao, por macrofagos peritoneais de camundongos

    Energy Technology Data Exchange (ETDEWEB)

    Cardi, Bruno Andrade

    1999-07-01

    The purpose was to investigate the uptake and endocytosis of 2000 Gy {sup 60}Co irradiated crotoxin through mouse peritoneal macrophages, correlating with native one and another non related protein, the ovalbumin. Native (CTXN) or 2000 Gy {sup 60} Co {gamma}-rays (dose rate 540 Gy/hour) irradiated crotoxin (CTXI) or ovalbumin processed of same manner (OVAN - OVAI) were offered to mouse peritoneal macrophages and their uptake was evaluated by immunohistochemistry and quantitative in situ ELISA. The involvement of scavenger receptors (ScvR) was evaluated by using blockers drugs (Probuco-PBC or Dextran Sulfate - SD) or with nonspecific blocking using fetal calf serum (FBS). The morphology and viability of macrophages were preserved during the experiments. CTXI showed irradiation-induced aggregates and formation of oxidative changing were observed on this protein after gamma rays treatment. By immunohistochemistry we could observe heavy stained phagocytic vacuole on macrophages incubated with CTXI, as compared with CTXN. Quantitatively by in situ ELISA, the sema pattern was observed, displaying a 2-fold CTXI incorporation. In presence of PBC or SD we could find a significant decrease of CTXI uptake but not of CTXN. However the CTXN uptake was depressed by FBS, not observed with CTXI. OVA, after gamma rays treatment, underwent a high degradation suffering a potent incorporation and metabolism by macrophages, with a major uptake of OVAI in longer incubation (120 minutes). Gamma rays ({sup 60} Co) produced oxidative changes on CTX molecule, leading to a uptake by ScvR-mice peritoneal macrophages, suggesting that the relation antigen-presenting cells and gamma rays-modified proteins are responsible for the better immune response presented by irradiated antigens. (author)

  3. In situ gamma-ray spectrometric analysis of radionuclide distributions at a commercial shallow land burial site

    International Nuclear Information System (INIS)

    Kirby, L.J.; Campbell, R.M.

    1984-10-01

    Gamma-ray spectrometric analysis conducted at the Maxey Flats, Kentucky (USA) shallow land burial site confirmed that the waste radionuclides have been retained largely within the restricted area of the burial site. Concentrations of 137 Cs and 60 Co were comparable with those originating from global fallout and lower than concentrations measured in several other areas having similar rainfall. In-situ spectrometric analyses, corroborated by soil sample and vegetation analyses, indicate that the site has influenced 60 Co levels slightly in the west drainage channel, but 137 Cs did not originate from the site. Concentrations of 60 Co, 90 Sr and 137 Cs determined in subsurface soils by well logging techniques confirmed that subsurface migration of waste-derived radionuclides to points outside the restricted area has not been a significant source of contamination of the environs adjacent to the site. 8 references, 8 figures

  4. DNA double-strand break and apoptosis induction in human lymphocytes in different cycle cell phases by 60Co gamma rays and Bragg peak protons of a medical beam

    International Nuclear Information System (INIS)

    Khachenkova, A.A.; Boreyko, A.V.; Mozhaeva, A.V.; Chausov, V.N.; Ravnachka, I.I.; Amov, I.; Tiunchik, S.I.

    2009-01-01

    A comparative analysis is made of the regularities in the formation of DNA double-strand break and apoptosis induction in peripheral human blood lymphocytes in different cell cycle phases after 60 Co gamma and extended Bragg peak proton irradiation. It is shown that the formation of apoptotic cells in a lymphocyte population increases linearly in all the cell cycle stages after proton irradiation. The maximal DNA double-strand break and apoptosis yield in lymphocytes is observed in the S phase of the cell cycle

  5. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  6. Screening of mutant strains producing phytase from A. niger by 60Co γ-ray irradiation

    International Nuclear Information System (INIS)

    Yang Pingping; Wang Yan; Tao Wenyi

    2004-01-01

    60 Co γ-ray was used to irradiate Aspergillus niger 447-92 for screening the mutant strain of producing phytase, and the effects of mutation induction were determined and analyzed. A mutant strain A. niger 496-1 with high level of phytase was selected, the phytase properties of A. niger 496-1 were analyzed

  7. Application of INAA complementary gamma ray photopeaks to homogeneity study of candidate reference materials

    International Nuclear Information System (INIS)

    Moreira, Edson G.; Vasconcellos, Marina B.A.; Lima, Ana P.S.; Catharino, Marilia G.M.; Maihara, Vera A.; Saiki, Mitiko

    2009-01-01

    Characterization and certification of reference materials, RMs, is a complex task involving many steps. One of them is the homogeneity testing to assure that key property values will not present variation among RM bottles. Good precision is the most important figure of merit of an analytical technique to allow it to be used in the homogeneity testing of candidate RMs. Due to its inherent characteristics, Instrumental Neutron Activation Analysis, INAA, is an analytical technique of choice for homogeneity testing. Problems with sample digestion and contamination from reagents are not an issue in INAA, as solid samples are analyzed directly. For element determination via INAA, the activity of a suitable gamma ray decay photopeak for an element is chosen and it is compared to the activity of a standard of the element. An interesting possibility is the use of complementary gamma ray photopeaks (for the elements that present them) to confirm the homogeneity test results for an element. In this study, an investigation of the use of the complementary gamma ray photopeaks of 110 mAg, 82 Br, 60 Co, 134 Cs, 152 Eu, 59 Fe, 140 La, 233 Pa (for Th determination), 46 Sc and 75 Se radionuclides was undertaken in the between bottle homogeneity study of a mussel candidate RM under preparation at IPEN - CNEN/SP. Although some photopeaks led to biased element content results, the use of complementary gamma ray photopeaks proved to be helpful in supporting homogeneity study conclusions of new RMs. (author)

  8. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Broomhead, Laurent.

    1980-01-01

    The nuclear gamma astronomy is presented, in particular the Gamma Ray Observatory, an enormous eight tonnes machine fitted with gamma telescopes, scheduled for launching around 1985. It is thereby hoped to study the natural nuclear reactions which occur when stars explode [fr

  9. Cosmic ray-dark matter scattering: a new signature of (asymmetric) dark matter in the gamma ray sky

    International Nuclear Information System (INIS)

    Profumo, Stefano; Ubaldi, Lorenzo

    2011-01-01

    We consider the process of scattering of Galactic cosmic-ray electrons and protons off of dark matter with the radiation of a final-state photon. This process provides a novel way to search for Galactic dark matter with gamma rays. We argue that for a generic weakly interacting massive particle, barring effects such as co-annihilation or a velocity-dependent cross section, the gamma-ray emission from cosmic-ray scattering off of dark matter is typically smaller than that from dark matter pair-annihilation. However, if dark matter particles cannot pair-annihilate, as is the case for example in asymmetric dark matter scenarios, cosmic-ray scattering with final state photon emission provides a unique window to detect a signal from dark matter with gamma rays. We estimate the expected flux level and its spectral features for a generic supersymmetric setup, and we also discuss dipolar and luminous dark matter. We show that in some cases the gamma-ray emission might be large enough to be detectable with the Fermi Large Area Telescope

  10. Effect of large dose gamma-ray irradiation on polyimide

    International Nuclear Information System (INIS)

    Morita, Yohsuke; Watanabe, Kiyoshi; Yagyu, Hideki.

    1988-01-01

    In the radiation environment of atomic energy, space and so on, with the heightening of the performance of equipment, the organic materials having the radiation resistance up to several hundreds MGy have been demanded. Polyimide is one of a small number of the polymers which are considered to be applicable to such environment. However, actually the characteristics as the insulator for such large dose radiation environment have not been sufficiently verified. In this study, the gamma-ray of as large dose as 100 MGy was irradiated on the polyimides having different chemical structure in the air and in nitrogen, and the change of their mechanical and electrical characteristics was elucidated, at the same time, the structural change was examined. The four kinds of polyimides used for the experiment were three kinds of thermosetting type and thermoplastic polyether imide. Co-60 gamma-ray was irradiated at the dose rate of 17 kGy/h at room temperature. The tensile properties, volume resistivity, dielectric tangent, gel fraction, glass transition temperature and IR spectra were examined. In the air, the characteristics lowered by large dose irradiation due to the severance of main chains. In nitrogen, the deterioration was extremely slight, and cross-linking occurred. (K.I.)

  11. Gamma-Ray Instrument for Polarimetry, Spectroscopy and Imaging (GIPSI)

    National Research Council Canada - National Science Library

    Kroeger, R. A; Johnson, W. N; Kinzer, R. L; Kurfess, J. D; Inderhees, S. E; Phlips, B. F; Graham, B. L

    1996-01-01

    .... Gamma-ray polarimetry in the energy band around 60-300 keV is an interesting area of high energy astrophysics where observations have not been possible with the technologies employed in current and past space missions...

  12. On-line interrogation of pebble bed reactor fuel using passive gamma-ray spectrometry

    Science.gov (United States)

    Chen, Jianwei

    with the relative activities of Cs-134/Co-60 (Co-60 is introduced as a dopant) to yield the burnup and enrichment for each pebble. Furthermore, a direct consequence of the relative approach is the ability to apply a self-calibration scheme using the multiple gamma lines of Ba-La-140 to establish the relative efficiency curve of the HPGe detector. An assessment of the expected uncertainty components in this approach showed that a maximum uncertainty of less than 5% should be feasible. To confirm the above findings, gamma-ray scans were performed on irradiated PULSTAR reactor fuel assemblies at North Carolina Sate University. The measurements used a 40% efficient n-type coaxial HPGe detector connected to an ORTEC DSPEC plus digital Gamma-Ray Spectrometer, and a data acquisition computer. The obtained results showed consistency with the predictions of the simulations including the observation of the I-132, Cs-134, Np-239 uncontaminated gamma lines. In addition, the Ba-La-140 lines were clearly observed confirming the ability to perform relative calibration of the spectrometer.

  13. Cosmic gamma-ray burst

    International Nuclear Information System (INIS)

    Yamagami, Takamasa

    1985-01-01

    Ballon experiments for searching gamma-ray burst were carried out by employing rotating-cross modulation collimators. From a very long observation of total 315 hours during 1975 to 1979, three gamma-ray intensity anomalies were observed which were speculated as a gamma-ray burst. As for the first gamma-ray intensity anomaly observed in 1975, the burst source could be located precisely but the source, heavenly body, could not be specified. Gamma-ray burst source estimation was made by analyzing distribution of burst source in the celestial sphere, burst size distribution, and burst peak. Using the above-mentioned data together with previously published ones, apparent inconsistency was found between the observed results and the adopted theory that the source was in the Galaxy, and this inconsistency was found due to the different time profiles of the burst observed with instruments of different efficiency. It was concluded by these analysis results that employment of logN - logP (relation between burst frequency and burst count) was better than that of logN - logS (burst size) in the examination of gamma-ray burst because the former was less uncertain than the latter. Analyzing the author's observed gamma-ray burst data and the related published data, it was clarified that the burst distribution was almost P -312 for the burst peak value larger than 10 -6 erg/cm 2 .sec. The author could indicate that the calculated celestial distribution of burst source was consistent with the observed results by the derivation using the logN - logP relationship and that the burst larger than 10 -6 erg/cm 2 .sec happens about one thousand times a year, about ten times of the previous value. (Takagi, S.)

  14. Gamma-ray observations of the Orion Molecular Clouds with the Fermi Large Area Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, M.; Ajello, M.; Allafort, A.; Antolini, E.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bottacini, E.; Brandt, T. J.; Bregeon, J.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Cecchi, C.; Chekhtman, A.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Conrad, J.; D' Ammando, F.; de Angelis, A.; de Palma, F.; Dermer, C. D.; do Couto e Silva, E.; Drell, P. S.; Drlica-Wagner, A.; Enoto, T.; Falletti, L.; Favuzzi, C.; Fegan, S. J.; Ferrara, E. C.; Focke, W. B.; Fukazawa, Y.; Fukui, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Germani, S.; Giglietto, N.; Giordano, F.; Giroletti, M.; Glanzman, T.; Godfrey, G.; Guiriec, S.; Hadasch, D.; Hanabata, Y.; Harding, A. K.; Hayashida, M.; Hayashi, K.; Horan, D.; Hou, X.; Hughes, R. E.; Jackson, M. S.; Jóhannesson, G.; Johnson, A. S.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kerr, M.; Knödlseder, J.; Kuss, M.; Lande, J.; Larsson, S.; Lee, S. -H.; Longo, F.; Loparco, F.; Lovellette, M. N.; Lubrano, P.; Makishima, K.; Mazziotta, M. N.; Mehault, J.; Mitthumsiri, W.; Moiseev, A. A.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nakamori, T.; Naumann-Godo, M.; Nishino, S.; Norris, J. P.; Nuss, E.; Ohno, M.; Ohsugi, T.; Okumura, A.; Orienti, M.; Orlando, E.; Ormes, J. F.; Ozaki, M.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pesce-Rollins, M.; Pierbattista, M.; Piron, F.; Pivato, G.; Porter, T. A.; Rainò, S.; Razzano, M.; Reimer, A.; Reimer, O.; Roth, M.; Sadrozinski, H. F. -W.; Sgrò, C.; Siskind, E. J.; Spandre, G.; Spinelli, P.; Strong, A. W.; Takahashi, H.; Takahashi, T.; Tanaka, T.; Thayer, J. G.; Thayer, J. B.; Tibolla, O.; Tinivella, M.; Torres, D. F.; Tramacere, A.; Troja, E.; Uchiyama, Y.; Usher, T. L.; Vandenbroucke, J.; Vasileiou, V.; Vianello, G.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Yang, Z.; Zimmer, S.

    2012-08-08

    We report on the gamma-ray observations of giant molecular clouds Orion A and B with the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. The gamma-ray emission in the energy band between ~100 MeV and ~100 GeV is predicted to trace the gas mass distribution in the clouds through nuclear interactions between the Galactic cosmic rays (CRs) and interstellar gas. The gamma-ray production cross-section for the nuclear interaction is known to ~10% precision which makes the LAT a powerful tool to measure the gas mass column density distribution of molecular clouds for a known CR intensity. We present here such distributions for Orion A and B, and correlate them with those of the velocity-integrated CO intensity (W CO) at a 1° × 1° pixel level. The correlation is found to be linear over a W CO range of ~10-fold when divided in three regions, suggesting penetration of nuclear CRs to most of the cloud volumes. The W CO-to-mass conversion factor, X CO, is found to be ~2.3 × 1020 cm-2(K km s–1)–1 for the high-longitude part of Orion A (l > 212°), ~1.7 times higher than ~1.3 × 1020 found for the rest of Orion A and B. We interpret the apparent high X CO in the high-longitude region of Orion A in the light of recent works proposing a nonlinear relation between H2 and CO densities in the diffuse molecular gas. W CO decreases faster than the H2 column density in the region making the gas "darker" to W CO.

  15. Measurements of {sup 60}Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999

    Energy Technology Data Exchange (ETDEWEB)

    Gasparro, J.; Hult, M. E-mail: mikael.hult@irmm.jrc.be; Komura, K.; Arnold, D.; Holmes, L.; Johnston, P.N.; Laubenstein, M.; Neumaier, S.; Reyss, J.-L.; Schillebeeckx, P.; Tagziria, H.; Van Britsom, G.; Vasselli, R

    2004-07-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes {gamma}-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring {sup 60}Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from {sup 60}Co activity is in agreement with previous measurements using the short-lived radionuclides {sup 51}Cr and {sup 59}Fe. Limits on contamination of the samples with {sup 60}Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using {sup 60}Co activation.

  16. Gamma-Ray Astronomy Technology Needs

    Science.gov (United States)

    Gehrels, N.; Cannizzo, J. K.

    2012-01-01

    In recent decades gamma-ray observations have become a valuable tool for studying the universe. Progress made in diverse 8re1lS such as gamma-ray bursts (GRBs), nucleosynthesis, and active galactic nuclei (AGNs) has complimented and enriched our astrophysical understanding in many ways. We present an overview of current and future planned space y-ray missions and discussion technology needs for- the next generation of space gamma-ray instruments.

  17. GRAP, Gamma-Ray Level-Scheme Assignment

    International Nuclear Information System (INIS)

    Franklyn, C.B.

    2002-01-01

    1 - Description of program or function: An interactive program for allocating gamma-rays to an energy level scheme. Procedure allows for searching for new candidate levels of the form: 1) L1 + G(A) + G(B) = L2; 2) G(A) + G(B) = G(C); 3) G(A) + G(B) = C (C is a user defined number); 4) L1 + G(A) + G(B) + G(C) = L2. Procedure indicates intensity balance of feed and decay of each energy level. Provides for optimization of a level energy (and associated error). Overall procedure allows for pre-defining of certain gamma-rays as belonging to particular regions of the level scheme, for example, high energy transition levels, or due to beta- decay. 2 - Method of solution: Search for cases in which the energy difference between two energy levels is equal to a gamma-ray energy within user-defined limits. 3 - Restrictions on the complexity of the problem: Maximum number of gamma-rays: 999; Maximum gamma ray energy: 32000 units; Minimum gamma ray energy: 10 units; Maximum gamma-ray intensity: 32000 units; Minimum gamma-ray intensity: 0.001 units; Maximum number of levels: 255; Maximum level energy: 32000 units; Minimum level energy: 10 units; Maximum error on energy, intensity: 32 units; Minimum error on energy, intensity: 0.001 units; Maximum number of combinations: 6400 (ca); Maximum number of gamma-ray types : 127

  18. Observation of solar gamma-ray by Hinotori

    International Nuclear Information System (INIS)

    Yoshimori, Masato; Okudaira, Kiyoaki; Hirashima, Yo; Kondo, Ichiro.

    1982-01-01

    The solar gamma-ray emitted by solar flare was observed. The gamma-ray is the electromagnetic radiation with the energy more than 300 keV. The line gamma-ray intensity and the time profile were observed. The gamma-ray detector CsI (Tl) was loaded on Hinotori, and the observed gamma-ray was analyzed by a multi-channel analyzer. The observed line gamma-ray was the radiation from Fe-56 and Ne-20. The line gamma-ray from C-12 and O-16 was also seen. These gamma-ray is the direct evidence of the nuclear reaction on the sun. The observed spectrum suggested the existence of the lines from Mg-24 and Si-28. The intensity of the 2.22 MeV gamma-line was small. This fact showed that the origin of this line was different from other nuclear gamma-ray. Two kinds of hard X-ray bursts were detected. The one was impulsive burst, and the other was gradual burst. There was no time difference between the hard X-ray and the gamma-ray of the impulsive burst. The impulsive burst may be explained by the beam model. The delay of time profile in the high energy gamma-ray of the gradual burst was observed. This means that the time when accelerated electrons cause bremsstrahlung depends on the electron energy. The long trapping of electrons at the top of magnetic loop is suggested. (Kato, T.)

  19. X-ray emission from open star clusters with Spectrum-Rontgen-Gamma

    DEFF Research Database (Denmark)

    Singh, K.P.; Ojha, D.K.; Schnopper, H.W.

    1998-01-01

    The study of X-ray emission from co-evolving populations of stars in open dusters is extremely important for understanding the dynamo activity among the stars. With this objective, we propose to observe a number of open clusters in the X-ray and UV bands using SPECTRUM-Rontgen-Gamma. The high...... throughput of SPECTRUM-Rontgen-Gamma will help detect main sequence stars like Sun in middle-aged and old clusters. We will study the relationships between various parameters - age, rotation, abundance, UBV colors, X-ray luminosity, coronal temperature etc. X-ray spectra of younger and brighter populations...

  20. Gamma ray sensitivity of superheated liquid

    International Nuclear Information System (INIS)

    Sawamura, Teruko; Sugiyama, Noriyuki; Narita, Masakuni

    2000-01-01

    }=exp{-(K γ Vφ γ +λ 0 )τ} (2). In the present experiment the superheated drop of trans-2-butene(C 4 H 8 , boiling temperature=0.8degC) was exposed to γ-rays and its life time was measured. The trans-2-butene becomes sensitive to γ-rays at higher temperatures and then the experiment was carried out at 80degC. The probability distribution of the life time X(τ') was obtained by 50 experiments with and without 60 Co γ-ray irradiation. From the results, the sensitivity per unit fluence K γ '[cm 2 ]=K γ V was estimated to be 1.32 x 10 -7 ±4.59 x 10 -8 [cm 2 ]. The life-time data were divided into three groups depending on the decompressed pressure. There was an increase in K γ ' with the decompressed pressure as was predicted from the theory of vaporization. (author)

  1. Low background gamma ray spectrometer using the anticoincidence shield technique at KAERI

    International Nuclear Information System (INIS)

    Byun, Jong In; Choi, Yun Ho; Kwak, Seung Im; Hwang, Han Yull; Chung, Kun Ho; Choi, Geun Sik; Park, Doo Won; Lee, Chang Woo

    2002-01-01

    We develop a ultra-low background gamma ray spectrometer, using active and passive shielding technique at the same time. Cosmic ray induced background is suppressed by means of active shield devices consisting of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shield is made of 150 mm thick walls of very low activity lead, especially 20 mm with activity of -1 and 0.36 s -1 with and without active shield, respectively, on the regions from 50 keV to 3 MeV. The detection efficiency curve has been precisely measured for regions from 80 keV to 2 MeV with a 10 3 ml marinelli beaker sample, made with calibrated mixed-sources consists of 109 Cd, 57 Co, 139 Ce, 203 Hg, 113 Sn, 85 Sr, 137 Cs, 60 Co and 88 Y. The virtues of the method are demonstrated by applying on experiment that requires the lowest detection limit

  2. Inverse dose-rate effect for the induction of 6-thioguanine-resistant mutants in Chinese hamster V79-S cells by 60Co gamma rays

    International Nuclear Information System (INIS)

    Crompton, N.E.; Barth, B.; Kiefer, J.

    1990-01-01

    Chinese hamster V79-S cells capable of growing in suspension culture were exposed to 60Co gamma rays at a high dose rate (84 Gy/h), low dose rates (200, 50, and 39 mGy/h), and a spectrum of very low dose rates (between 29 and 4.5 mGy/h). Following time for appropriate expression the cultures were assayed for the induction of 6-thioguanine-resistant mutants. For a given dose, a decrease in mutation induction occurred as the dose rate was reduced from high dose rates to low dose rates. However, further reduction in dose rate resulted in a reverse dose-rate effect, and an increase in the frequency of mutants was observed. The contribution of background mutation frequency to this reverse dose-rate effect was studied, both by examining fluctuations of mutation frequency in nonirradiated culture and by its impact upon the dose-rate-independent nature of the reversed effect, and it was found to be negligible. The physiological state of the suspension culture under periods of protracted exposure to very low dose rates was also investigated. The effect of doubling time, plating efficiency, cell cycle distribution, and sensitivity on survival and mutation were examined. In no case was a change apparent during the very low-dose-rate exposures. The results are discussed in terms of the possible expression of cryptic radiation damage after prolonged culture times and/or the involvement of an error-free repair system which requires a certain amount of radiation damage to become active

  3. Determination of {sup 60}Co sorption in natural clinoptilolite; Determinacion de la sorcion de {sup 60}Co en clinoptilolita natural

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez B, E.; Granados C, F. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    It was studied the clinoptilolite behavior coming from a deposit in Taxco, Guerrero in hydration and stabilization conditions with sodium for determining its sorption properties. The ion exchange process was carried out through gamma spectrometry using a CoCl{sub 2} solution marked with {sup 60} Co at p H 6.5 in different contact times. It was observed a maximum sorption of 0.408 m eq Co{sup +2}/g mineral, from 0.314 m eq Co{sup +2}/g mineral correspond at ion exchange. (Author)

  4. Relativistic motion in gamma-ray bursts

    International Nuclear Information System (INIS)

    Krolik, J.H.; Pier, E.A.

    1991-01-01

    Three fundamental problems affect models of gamma-ray bursts, i.e., the energy source, the ability of high-energy photons to escape the radiation region, and the comparative weakness of X-ray emission. It is indicated that relativistic bulk motion of the gamma-ray-emitting plasma generically provides a solution to all three of these problems. Results show that, if the plasma that produces gamma-ray bursts has a bulk relativistic velocity with Lorentz factor gamma of about 10, several of the most troubling problems having to do with gamma-ray bursts are solved. 42 refs

  5. Determination of 60Co sorption in natural clinoptilolite

    International Nuclear Information System (INIS)

    Hernandez B, E.; Granados C, F.

    1997-01-01

    It was studied the clinoptilolite behavior coming from a deposit in Taxco, Guerrero in hydration and stabilization conditions with sodium for determining its sorption properties. The ion exchange process was carried out through gamma spectrometry using a CoCl 2 solution marked with 60 Co at p H 6.5 in different contact times. It was observed a maximum sorption of 0.408 m eq Co +2 /g mineral, from 0.314 m eq Co +2 /g mineral correspond at ion exchange. (Author)

  6. Different gene expression of Normal lymphobloastoid cells which exposure to different dose of 60Co γ-ray

    International Nuclear Information System (INIS)

    Xiao Yao; Yang Jian; Gao Xian; Qin Yanghua; Sun Ding; Hai Ling

    2008-01-01

    Objective: To study on the gene expression of normal lymphoblastoid cells(AHH-1) which exposure to difference dose of 60 Co γ-ray, analyses the essential different biological effect.. Methods Human AHH-1 normal line was irradiated by 60 Co γ-rays. Used human cDNA microarray to develop the transcriptional levels of the genes by hybridizing the mRNA of cells 8 h after exposured in different dose and the control cells. Cluster analysis, discrimination and bolting were used to filter the effective genes of differential expression. Results The results of data analysis showed 23 genes of differential expression closely related to biological effect of 2.0 Gy radiation, 5 genes express changed only by 0.5 Gy radiation, 5 genes express apparently both in 2.0 Gy and 0.5 Gy radiation. Conclusion: The different dose γ-rays radiation-induced significant changes in gene expression, such as PAPLN, TP53INP1, PTENP1, FOS and TPR seem to be some important components of cellular radioresponse. (authors)

  7. Effect of Gamma Ray Energies and Steel Fiber addition by Weight on some Shielding Properties of Limestone Concrete

    International Nuclear Information System (INIS)

    Abd El-Latifa, A.A.; Ikraiam, F.A.; Abd El-Latifa, A.A.; Abd Elazziz, A.; Abd Elazziz, A.

    2010-01-01

    The mass attenuation coefficient , the build up factor , the half value thickness X 1/2 , and tenth value thickness X 1/10 of fiber concrete , 0% , 1% , 2%, 3%, and 4% by weight fiber content were measured at different gamma ray energies in MeV, 0.511,1.274 from Na-22 ,1.17 ,1.33 from Co-60 and 0.662 from Cs-137 . Appreciable variations were noted in the former nuclear parameters, due to the changes in the fiber content and gamma ray energies .A comparison of shielding properties of concrete with fiber content and reference sample(concrete without fiber ) have proven that the addition of steel fibers by weight to concrete have a potential application as a radiation shielding

  8. Mutagenic effects of gamma rays on the frequency and spectrum of chlorophyll and viable macro mutations in chilli (Capsicum annuum L.)

    International Nuclear Information System (INIS)

    Rangaiah, S.; Manjunath, A.; Puttaramanaik

    2004-01-01

    In the present study, uniform dry and healthy seeds of two cultivars of chilli namely Ceylon and Byadagi were exposed to 60 Co gamma rays at 5, 10, 15, 20, 25, 30, 35 and 40 krad doses at BARC, Mumbai. Thus there were total 18 treatments, eight different doses of gamma rays and one control in each cultivar. The M2 populations were compared with the respective control populations for chlorophyll and viable mutations. The treated populations were compared with the respective control populations for chlorophyll mutations (M2 and M3) and viable mutations (M2)' The results of the study are presented

  9. Highlights of GeV Gamma-Ray Astronomy

    Science.gov (United States)

    Thompson, David J.

    2010-01-01

    Because high-energy gamma rays are primarily produced by high-energy particle interactions, the gamma-ray survey of the sky by the Fermi Gamma-ray Space Telescope offers a view of sites of cosmic ray production and interactions. Gamma-ray bursts, pulsars, pulsar wind nebulae, binary sources, and Active Galactic Nuclei are all phenomena that reveal particle acceleration through their gamma-ray emission. Diffuse Galactic gamma radiation, Solar System gamma-ray sources, and energetic radiation from supernova remnants are likely tracers of high-energy particle interactions with matter and photon fields. This paper will present a broad overview of the constantly changing sky seen with the Large Area Telescope (LAT) on the Fermi spacecraft.

  10. Effects of gamma-rays irradiation on tracking resistance of organic insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Du, Boxue; Suzuki, Akio; Kobayashi, Shigeo [Tokyo Univ. of Agriculture and Technology, Koganei (Japan). Faculty of Technology

    1996-04-01

    This paper describes the influence of gamma-rays irradiation on tracking failure of organic insulating materials by use of the IEC Publ.112 method. Tracking resistance of organic insulating materials under wet polluted condition has been studied by many investigators with a test method of the IEC Publ.112. The investigations on irradiation effects on tracking resistance should be enhanced due to the increasing usage of organic insulating materials in the radiation environments. The tracking resistance seems to be affected by gamma-irradiation, but the knowledge on the influence of gamma-irradiation is quite a few and systematic studies are needed. In this paper, modified polyphenylene oxide, polybutylene naphthalate, modified polycarbonate and polybutylene terephthalate which were irradiated in air until 1x10{sup 7}R and 1x10{sup 8}R with dose rate of 10{sup 6}R/hr using {sup 60}Co gamma-source have been employed. The total dose effects on the number of drops to tracking failure, contact angle and charges of scintillation have been studied. As the total doses are increased, the number of drops to tracking failure decreases with polybutylene terephthalate. On the other hand, the number of drops to tracking failure increases with polybutylene naphthalate and modified polycarbonate when the total doses are increased. The effects of gamma-rays irradiation on tracking failure are due to radiation-induced degradation or cross-linking of organic insulating materials. When the organic insulating materials are degraded by gamma-irradiation, the tracking resistance decreases, but for cross-linking type materials, the tracking resistance increases. (author)

  11. Localization of Gamma-Ray Bursts Using the Fermi Gamma-Ray Burst Monitor

    NARCIS (Netherlands)

    Connaughton, V.; Briggs, M.S.; Goldstein, A.; Meegan, C.A.; Paciesas, W.S.; Preece, R.D.; Wilson-Hodge, C.A.; Gibby, M.H.; Greiner, J.; Gruber, D.; Jenke, P.; Kippen, R.M.; Pelassa, V.; Xiong, S.; Yu, H-F.; Bhat, P.N.; Burgess, J.M.; Byrne, D.; Fitzpatrick, G.; Foley, S.; Giles, M.M.; Guiriec, S.; van der Horst, A.J.; von Kienlin, A.; McBreen, S.; McGlynn, S.; Tierney, D.; Zhang, B..B.

    2015-01-01

    The Fermi Gamma-ray Burst Monitor (GBM) has detected over 1400 gamma-ray bursts (GRBs) since it began science operations in 2008 July. We use a subset of over 300 GRBs localized by instruments such as Swift, the Fermi Large Area Telescope, INTEGRAL, and MAXI, or through triangulations from the

  12. Gamma-Ray Lenses for Astrophysics-and the Gamma-Ray Imager Mission GRI

    DEFF Research Database (Denmark)

    Wunderer, C. B.; Ballmoos, P. V.; Barriere, N.

    2009-01-01

    Observations of the gamma-ray sky reveal the most powerful sources and the most violent events in the Universe. While at lower wavebands the observed emission is generally dominated by thermal processes, the gamma-ray sky provides us with a view on the non-thermal Universe. Here particles are acc...

  13. Characterization of barite and crystal glass as attenuators in X-ray and gamma radiation shieldings

    International Nuclear Information System (INIS)

    Almeida Junior, Airton Tavares de

    2005-03-01

    Aiming to determine the barium sulphate (BaSO 4 ) ore and crystal glass attenuation features, both utilized as shieldings against ionizing X and gamma radiations in radiographic installations, a study of attenuation using barite plaster and barite concrete was carried out, which are used, respectively, on wall coverings and in block buildings. The crystal glass is utilized in screens and in windows. To do so, ten plates of barite plaster and three of barite concrete with 900 cm 2 and with an average thickness ranging from 1 to 5 cm, and three plates of crystal glass with 323 cm 2 and with thicknesses of 1, 2 and 4 cm were analyzed. The samples were irradiated with X-rays with potentials of 60, 80, 110 and 150 kilovolts, and also with 60 Co gamma rays. Curves of attenuation were obtained for barite plaster and barite concrete (mGy/mA.min) and (mGy/h), both at 1 meter, as a function of thickness and curve of transmission through barite plaster and barite concrete as a function of the thickness. The equivalent thicknesses of half and tenth value layers for barite plaster, barite concrete and crystal glass for all X-Ray energies were also determined. (author)

  14. Method of separation of celestial gamma-ray bursts from solar flares

    International Nuclear Information System (INIS)

    Chuang, K.W.; White, R.S.; Klebesadel, R.W.; Laros, J.G.

    1991-01-01

    We recently discovered 217 ''new'' celestial gamma-ray burst candidates from the ''new'' burst search of the PVO real time data base. 1 The burst search covered the time period from September 1978 to July 1988. Sixty were confirmed by at lest on other spacecraft, e.g., ISEE-3, V-11, V-12, etc. None triggered the PVO high time resolution memory. In this paper we describe a new algorithm based ont eh relationship between time width T w and hardness ratio HR, to distinguish cosmic gamma-ray bursts from solar flares without knowing the directions of the events. The criteria for identification as a gamma-ray burst candidate are: If T ww ≤a then HR≥bT w , or T w >a then HR>c. Otherwise, the event is a solar flare candidate. Here, a, b, and c are parameter which differ for different gamma-ray burst detectors. For PVO, a=18.8 s, b=(1.38/18.8) s -1 , and c=1.38. This algorithm was tested with 83 triggered and 60 nontriggered confirmed gamma-ray burst and 30 confirmed solar flares from PVO

  15. Influence Of Dilution Factor For Activity Measurement Of 60CO

    International Nuclear Information System (INIS)

    Hermawan-Candra; Nazaroh; Ermi-Juita

    2003-01-01

    Influence of dilution factor for activity measurement of 60 Co has been studied. The aim of this research is to determine influence between activity measurement result of 60 Co before and after diluted. Measurement were done by using ionization chamber detectors system and gamma spectrometry system with NaI(TI) detector. Discrepancy within three ionization chambers measurements were 0.2% - 2.1% and NaI(Tl) were 3.5% - 6%. (author)

  16. Gamma ray astronomy with COS-B

    International Nuclear Information System (INIS)

    Swanenburg, B.N.

    1981-01-01

    Observational results in the field of gamma-ray astronomy that have been obtained to date with the COS-B satellite are discussed and questions raised by these observations are summarized. Following a brief review of the instrumental characteristics of COS-B and the extent of COS-B gamma-ray coverage of the sky, particular attention is given to the questions raised by the discovery of many unidentified gamma-ray sources with no apparent optical, X-ray or radio counterparts and the detection of high-energy gamma radiation from the quasar 3C 273, which suggests the role of gamma-ray emission in the creation of other radiation

  17. Inverse Compton gamma-rays from pulsars

    International Nuclear Information System (INIS)

    Morini, M.

    1983-01-01

    A model is proposed for pulsar optical and gamma-ray emission where relativistic electrons beams: (i) scatter the blackbody photons from the polar cap surface giving inverse Compton gamma-rays and (ii) produce synchrotron optical photons in the light cylinder region which are then inverse Compton scattered giving other gamma-rays. The model is applied to the Vela pulsar, explaining the first gamma-ray pulse by inverse Compton scattering of synchrotron photons near the light cylinder and the second gamma-ray pulse partly by inverse Compton scattering of synchrotron photons and partly by inverse Compton scattering of the thermal blackbody photons near the star surface. (author)

  18. Air kerma national standard of Russian Federation for x-ray and gamma radiation. Activity SSDL/VNIIM in medical radiation dosimetry field

    International Nuclear Information System (INIS)

    Kharitonov, I.A.; Villevalde, N.D.; Oborin, A.V.; Fominykh, V.I.

    2002-01-01

    Primary standard of unities air kerma and air kerma rate X-ray and gamma radiation, placed at VNIIM, consists of: plate-parallel free-air ionization chamber IK 10-60 for low-energy X-ray in the generating potential range from 10 to 50 kV; plate-parallel free-air ionization chamber IK 50-400 for medium-energy X-ray in the generating potential range from 50 to 300 kV; cavity cylindrical graphite chambers C1 and C30 with volumes 1 cm 3 and 30 cm 3 for reproduction and transmission the dimensions gamma radiation unities using Cs-137 and Co-60 sources. The next irradiation facilities are used at VNIIM: in low-energy X-ray range: a constant-potential high-voltage generator and a tungsten-anode Xray tube with inherent filtration of around 1 mm Be; in medium-energy X-ray range: set on the basis of an industrial X-ray apparatus Isovolt-400 and a tungsten-anode X-ray tube with inherent filtration of around 3,5 mm Al; in gamma radiations field: units with a radioactive sources Cs-137 with activity 140 and 1200 GBq and Co-60 with activity 120 GBq and irradiation set with a source from Co-60 (activity 3200 GBq). The last one belongs to Central Research Institute for Radiology and Roentgenology (CNIRRI). For measuring currents and charges of standard chambers we use electrometers such as Keithley of model 6517A and B7-45 manufactured by 'Belvar' (Republic Belarus). The reference radiation qualities L, N, H series according to ISO 4037 and the radiation qualities RQR, RQA and RQF according to IEC 61267 for calibration and verification of the therapeutic, diagnostic measurement means are realized in the low-energy and medium-energy X-ray standards. The VNIIM air kerma primary standard of has been participated in the international comparisons: key comparison BIPM.R1(I)-K1 for gamma radiation of Co-60 in 1997; supplementary comparisons BIPM.R1(I)-S10 for gamma radiation of Cs-137 in 1997; key comparison BIPM.R1(I)-K2 for low-energy X-ray range in 1998; key comparison BIPM.R1(I)-K3

  19. Planetary gamma-ray spectroscopy: the effects of hydrogen absorption cross-section of the gamma-ray spectrum

    International Nuclear Information System (INIS)

    Lapides, J.R.

    1981-01-01

    The gamma-ray spectroscopy of planet surfaces is one of several possible methods that are useful in determining the elemental composition of planet surfaces from orbiting spacecraft. This has been demonstrated on the Apollos 15 and 16 missions as well as the Soviet Mars-5 mission. Planetary gamma-ray emission is primarily the result of natural radioactive decay and cosmic-ray and solar-flare-induced nuclear reactions. Secondary neutron reactions play a large role in the more intense gamma-ray emission. The technique provides information on the elemental composition of the top few tens of centimeters of the planet surface. Varying concentrations of hydrogen and compositional variations that alter the macroscopic thermal-neutron absorption cross section have a significant effect on the neutron flux in the planet surface and therefore also on the gamma-ray emission from the surface. These effects have been systematically studied for a wide range of possible planetary compositions that include Mercury, the moon, Mars, the comets, and the asteroids. The problem of the Martian atmosphere was also investigated. The results of these calculations, in which both surface neutron fluxes and gamma-ray emission fluxes were determined, were used to develop general procedures for obtaining planet compositions from the gamma-ray spectrum. Several changes have been suggested for reanalyzing the Apollos 15 and 16 gamma-ray results. In addition, procedures have been suggested that can be applied to neutron-gamma techniques in mineral and oil exploration

  20. 60Co γ-ray attenuation coefficient of barite concrete

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Bayat, T.; Dashti, M. H.; Ghisari, J.; Abdoli, N.

    2006-01-01

    Recently, the use of medium and high energy X-rays has increased in Iran, and radiotherapy centers along with a variety of accelerators have been installed in some provinces. Hence, there is not sufficient skill in designing and installing radiotherapy treatment rooms. This study was conducted to evaluate the efficacy of different mixtures of barite concrete for shielding the radiotherapy rooms. This way, we have emphasized on determining the size and amount of barite aggregations to achieve the maximum radiation attenuation which leads to minimizing wall thickness in treatment room. Materials and Methods: To increase concrete density, the barite aggregation was added to concrete. Different size variations of barite aggregates mixed with different water/cement ratio were examined. The dimension of cubic concrete specimens for compression strength test was 15*15*15 cm. The rectangular barite concrete blocks with different compressions as used for strength test with cross section of 10*10 cm, and thicknesses from 5 to 40 cm were used for radiation attenuation test. To do so, concrete specimens were irradiated by gamma beam of 60 Co (Phoenix Theratron). The transmission radiation through the blocks was measured by a Farmer ionization chamber (Fc 65 P). Results: Our findings showed that in all specimens the highest mean compression strength was related to the specimens with equal ratio of fine to coarse barite aggregates, but the lowest half value layer was obtained from mixtures with fine to coarse ratio of 35/65. The concrete sample with a 0.45 water/cement ratio, 350 kg/m3 cement and equal amounts of fine and coarse barite sands had nearly minimum half value layer (half value layer), and maximum compression strength, so the sample was considered as the best barite concrete sample. Conclusion: Since half value layer of the barite concrete specimens with the same compression strength is markedly lower than the conventional concrete, and that there are quite a number

  1. Gamma Ray Bursts-Afterglows and Counterparts

    Science.gov (United States)

    Fishman, Gerald J

    1998-01-01

    Several breakthrough discoveries were made last year of x-ray, optical and radio afterglows and counterparts to gamma-ray bursts, and a redshift has been associated with at least one of these. These discoveries were made possible by the fast, accurate gamma-ray burst locations of the BeppoSAX satellite. It is now generally believed that the burst sources are at cosmological distances and that they represent the most powerful explosions in the Universe. These observations also open new possibilities for the study of early star formation, the physics of extreme conditions and perhaps even cosmology. This session will concentrate on recent x-ray, optical and radio afterglow observations of gamma-ray bursts, associated redshift measurements, and counterpart observations. Several review and theory talks will also be presented, along with a summary of the astrophysical implications of the observations. There will be additional poster contributions on observations of gamma-ray burst source locations at wavelengths other than gamma rays. Posters are also solicited that describe new observational capabilities for rapid follow-up observations of gamma-ray bursts.

  2. Monte Carlo investigation of design aspects of indigenously developed 120 Ci 60Co based industrial radiography device

    International Nuclear Information System (INIS)

    Palam Selvam, T.; Vishwakarma, R.S.; Sahoo, Dhiren K.; Sharma, Manoj K.; Srivastava, Piyush

    2016-01-01

    Industrial Radiography is an indispensable, versatile and well-established non destructive testing (NDT). Industrial radiography is carried out by using industrial radiography gamma exposure devices (IGRED) housing 60 Co and 192 Ir radioactive sources, and Industrial X-ray machines/accelerators. IGRED is an assembly of components which includes source housing, exposure mechanism, source drive system, pig tail, and source conduit. In the present study, we investigated the shielding design aspects of 120 Ci 60 Co-based IRGED using the Monte Carlo methods (MCNP version 3.1). The design details were provided by Board of Radiation and Isotope Technology (BRIT). As the objective is to finalize the suitable design of the device, we also included additional designs. The work also included measurements around the device using TLDs

  3. Decomposition of ρ-nonylphenols in water by 60Co γ-ray irradiation

    International Nuclear Information System (INIS)

    Kimura, Atsushi; Taguchi, Mitsumasa; Kojima, Takuji; Namba, Hideki

    2005-01-01

    ρ-Nonylphenols (NPs), one of endocrine disrupting chemicals, are used as plastic flexibilizers or nonionic surfactants, and widely released into the water environment. Hydroxyl radicals produced from water molecules by γ-ray irradiation have high oxidation reactivity. Recently, treatments with the hydroxyl radicals have drawn much attention to conserve the water environment. In this study, decompositions of NPs in water were investigated using hydroxyl radicals by 60 Co γ-rays irradiation. The concentrations of the NPs at initial concentration from 45 to 1000 nM were decomposed by γ-ray irradiation. Qualitative and quantitative analyses of NPs were carried out by high performance liquid chromatography. The decomposition curves of NPs at each initial concentration were analyzed as single exponential functions. Alkylphenol activity of aqueous NPs solution, which was estimated by enzyme-linked immunosorbent assay, implies the irradiation products have alkylphenol activity. Two products having molecular weight of 236 were investigated by liquid chromatography-mass spectrometry, and were considered to be ρ-nonylcatechol and 1-(ρ-hydroxyphenyl)-1-nonanol on the basis of the oxidation mechanisms of ρ-cresol and 4-ethylphenol. (author)

  4. Delayed K562 cell apoptosis promoted by cleaved LyGDI after 60Co γ-rays irradiation

    International Nuclear Information System (INIS)

    Sun Huali; Duan Weiming; Shao Yanyan; Xiao Hainan; Zhou Xinwen

    2010-01-01

    Objective: To elucidate the function and regulatory mechanism of LyGDI involved delayed cell death in the human K562 cells and HL-60 cells induced by 60 Co γ-rays. Methods: Erythrosine B cells staining was used to count the apoptosis rate. PI staining and flow cytometry were applied to check the cell cycle. The expression of LYGDI and Rac1 was resolved by Western blot by using monoclonal antibody of LyGDI and Rac1. The distribution of Rac1 protein in cells was observed with immunofluorescence by using the confocal microscope. Results: The K562 cells showed G 2 /M phase arrest and the percent age was 71.3%. The apoptosis rate was very low at early post-irradiation stage in the K562 cells. The apoptosis rate was 14% in the K562 cells at 24 h post-irradiation with 8 Gy of γ-rays, and delayed cell apoptosis was present. LyGDI was cleaved in the K562 cells irradiated by 4 Gy 60 Co γ-rays after 24 hours post-irradiation. The expression of Rac1 protein was not altered at all, but the distribution was changed in the irradiated cells while the Rac1 protein moved to cell membrane and a little in cell nucleus. The Rac1 was activated with the losing the binding affinity with the LyGDI. Conclusion: LyGDI could promote the delayed cell apoptosis, which is through the activation of the Rac1. (authors)

  5. RBE [relative biological effectiveness] of tritium beta radiation to gamma radiation and x-rays analyzed by both molecular and genetic methods

    International Nuclear Information System (INIS)

    Lee, W.R.

    1988-01-01

    The relative biological effectiveness (RBE) of tritium beta radiation to 60 Co gamma radiation was determined using sex-linked recessive lethals (SLRL) induced in Drosophila melanogaster spermatozoa as the biological effect. The SLRL test, a measure of mutations induced in germ cells transmitted through successive generations, yields a linear dose-response curve in the range used in these experiments. From these ratios of the slopes of the 3 H beta and the 60 Co gamma radiation linear dose response curves, an RBE of 2.7 is observed. When sources of error are considered, this observation suggests that the tritium beta particle is 2.7 ± 0.3 times more effective per unit of energy absorbed in inducing gene mutations transmitted to successive generation than 60 Co gamma radiation. Ion tracks with a high density of ions (high LET) are more efficient than tracks with a low ion density (low LET) in inducing transmissible mutations, suggesting interaction among products of ionization. Molecular analysis of x-ray induced mutations shows that most mutations are deletions ranging from a few base pairs as determined from sequence data to multi locus deletions as determined from complementation tests and Southern blots. 14 refs., 1 fig

  6. Effects of gamma rays on non-vascular smooth muscles contractions (rat small intestine)

    International Nuclear Information System (INIS)

    Azroony, R.; Ksies, F.; Alya, G.

    2003-03-01

    In this experiment, the contractile response evoked by activating the membranous cholinergic and adrenergic receptors in the smooth muscular fibres isolated from jejunum in rat small intestine is studied. Also the effect of gamma rays on regulating this contractile response after exposing the whole body of the animals to different doses of gamma rays (3, 5 and 7 Gy) emitted from 60 Co source is studied. Results show that irradiation lessens the sensitivity of muscarinic cholinergic receptors to their agonists in a dose dependent manner. And there is an important shift on irradiated rats where the maximum effect of acetylcholine (E max) can be obtained in higher concentrations of acetylcholine. Concerning the effects of gamma rays on adrenergic receptors, our results show that irradiation, also, decreases the sensitivity of α1 adrenergic receptors to their agonists, and this decrease is represented in a decrease of the irradiated muscular fibers response to the inhibitory effect of phenylephrine (more specific to α1 adrenergic receptors than α2 adrenergic receptors) in a dose dependent manner. While we have found that α2 adrenergic receptors have no important effect on regulating the contractile response of the smooth muscular fibers in the rat jejunum neither in smooth muscular fibers isolated from control animals nor in those fibers which where isolated from irradiated animals. (author)

  7. Lunar occultations for gamma-ray source measurements

    Science.gov (United States)

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  8. Future prospects for. gamma. -ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Fichtel, C [National Aeronautics and Space Administration, Greenbelt, MD (USA). Goddard Space Flight Center

    1981-06-30

    As ..gamma..-ray astronomy moves from the discovery to the exploratory phase, the promise of ..gamma..-ray astrophysics noted by theorists in the late 1940s and 1950s is beginning to be realized. In the future, satellites should carry instruments that will have over an order of magnitude greater sensitivity than those flown thus far, and, for at least some portions of the ..gamma..-ray energy range, these detectors will also have substantially improved energy and angular resolution. The information to be obtained from these experiments should greatly enhance our knowledge of several astrophysical phenomena including the very energetic and nuclear processes associated with compact objects, astrophysical nucleosynthesis, solar particle acceleration, the chemical composition of the planets and other bodies of the Solar System, the structure of our Galaxy, the origin and dynamic pressure effects of the cosmic rays, high energy particles and energetic processes in other galaxies especially active ones, and the degree of matter-antimatter symmetry of the Universe. The ..gamma..-ray results of the forthcoming programs such as Gamma-I, the Gamma Ray Observatory, the ..gamma..-ray burst network, Solar Polar, and very high energy ..gamma..-ray telescopes on the ground will almost certainly provide justification for more sophisticated telescopes. These advanced instruments might be placed on the Space Platform currently under study by N.A.S.A.

  9. The relative biological effectiveness of 60Co γ-rays, 55 kVp X-rays, 250 kVp X-rays, and 11 MeV electrons at low doses

    International Nuclear Information System (INIS)

    Spadinger, I.; Palcic, B.

    1992-01-01

    The RBE of selected low-LET radiation modalities (55 kVp X- rays, 250 kVp X-rays, 60 Co γ-rays, and 11 MeV electrons) was investigated for survival of two cell lines (V79 and CHO). Detailed measurements were made in the 0 to 3 Gy dose range using an image cytometry device to accurately determine the number of cells assayed at each dose point. Data were also collected in the high dose range (0 to 10 Gy) using conventional counting and plating techniques. RBE values (#+- #1 SE) varied from 1.0±0.07 (V79 cells) and 1.2± 0.05 (CHO cells) at high doses to 1.3±0.07 (V79) and 1.4±0.1 (CHO) at low doses for 55 kVp X-rays, from 1.1±0.05 (V79) and 1.1±0.04 (CHO) at high doses to 1.1±0.06 (V79) and 1.2±0.2 (CHO) at low doses for 250 kVp X-rays, and from 1.1±0.08 (V79) and 1.0±0.04 (CHO) at high doses to 1.0±0.06 (V79) and 0.9±0.1 (CHO) at low doses for 11 MeV electrons. Only the low and high dose RBEs for 55 kVp X-rays relative to 60 Co γ-rays were significantly different. (author)

  10. Radio Observations of Gamma-ray Novae

    Science.gov (United States)

    Linford, Justin D.; Chomiuk, L.; Ribeiro, V.; project, E.-Nova

    2014-01-01

    Recent detection of gamma-ray emission from classical novae by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope surprised many in the astronomical community. We present results from radio observations, obtained using the Karl G. Jansky Very Large Array (VLA), of three gamma-ray novae: Mon2012, Sco2012, and Del2013. Radio observations allow for the calculation of ejecta masses, place limits on the distances, and provide information about the gamma-ray emission mechanism for these sources.

  11. The Gamma-Ray Imager GRI

    Science.gov (United States)

    Wunderer, Cornelia B.; GRI Collaboration

    2008-03-01

    Observations of the gamma-ray sky reveal the most powerful sources and the most violent events in the Universe. While at lower wavebands the observed emission is generally dominated by thermal processes, the gamma-ray sky provides us with a view on the non-thermal Universe. Here particles are accelerated to extreme relativistic energies by mechanisms which are still poorly understood, and nuclear reactions are synthesizing the basic constituents of our world. Cosmic accelerators and cosmic explosions are major science themes that are addressed in the gamma-ray regime. ESA's INTEGRAL observatory currently provides the astronomical community with a unique tool to investigate the sky up to MeV energies and hundreds of sources, new classes of objects, extraordinary views of antimatter annihilation in our Galaxy, and fingerprints of recent nucleosynthesis processes have been discovered. NASA's GLAST mission will similarly take the next step in surveying the high-energy ( GeV) sky, and NuSTAR will pioneer focusing observations at hard X-ray energies (to 80 keV). There will be clearly a growing need to perform deeper, more focused investigations of gamma-ray sources in the 100-keV to MeV regime. Recent technological advances in the domain of gamma-ray focusing using Laue diffraction and multilayer-coated mirror techniques have paved the way towards a gamma-ray mission, providing major improvements compared to past missions regarding sensitivity and angular resolution. Such a future Gamma-Ray Imager will allow the study of particle acceleration processes and explosion physics in unprecedented detail, providing essential clues on the innermost nature of the most violent and most energetic processes in the Universe.

  12. Thermal, tensile and rheological properties of high density polyethylene (HDPE) processed and irradiated by gamma-ray in different atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Ferreto, H. F. R., E-mail: hferreto@ipen.br, E-mail: ana-feitoza@yahoo.com.br; Oliveira, A. C. F., E-mail: hferreto@ipen.br, E-mail: ana-feitoza@yahoo.com.br; Parra, D. F., E-mail: dfparra@ipen.br, E-mail: ablugao@ipen.br; Lugão, A. B., E-mail: dfparra@ipen.br, E-mail: ablugao@ipen.br [Center of Chemistry and Environment, Institute of Energy and Nuclear Research - IPEN (Brazil); Gaia, R., E-mail: renan-gaia7@hotmail.com [Faculdades Oswaldo Cruz (Brazil)

    2014-05-15

    The aim of this paper is to investigate structural changes of high density polyethylene (HDPE) modified by ionizing radiation (gamma rays) in different atmospheres. The gamma radiation process for modification of commercial polymers is a widely applied technique to promote new physical-chemical and mechanical properties. Gamma irradiation originates free radicals which can induce chain scission or recombination, providing its annihilation, branching or crosslinking. This polymer was irradiated with gamma source of {sup 60}Co at doses of 5, 10, 20, 50 or 100 kGy at a dose rate of 5 kGy/h. The changes in molecular structure of HDPE, after gamma irradiations were evaluated using thermogravimetric analysis (TGA) and tensile machine and oscillatory rheology. The results showed the variations of the properties depending on the dose at each atmosphere.

  13. Storage behavior of an early garlic (Allium sativum L.) subject to gamma-ray radioinhibition

    International Nuclear Information System (INIS)

    Croci, C.A.; Curzio, O.A.; Arguello, J.A.

    1990-01-01

    Garlic bulbs of an early cultivar (Rosado Paraguayo) were irradiated with a dose of 50 Gy of Co-60 gamma rays at 30 days after harvest. Experimental lots were stored up to 300 days in a commercial warehouse (6-32 degrees C; R.H. 40-50%). The treatment reduced the weight loss of the bulbs and increased the percentage of both marketable bulbs and cloves without affecting organoleptic properties. The results show that both the raw/fresh market for this early cultivar and the garlic processing industry would profit from the radioinhibition process

  14. Observation of gamma-ray bursts with GINGA

    International Nuclear Information System (INIS)

    Murakami, Toshio; Fujii, Masami; Nishimura, Jun

    1989-01-01

    Gamma-ray Burst Detector System (GBD) on board the scientific satellite 'GINGA' which was launched on Feb. 5, 1987, was realized as an international cooperation between ISAS and LANL. It has recorded more than 40 Gamma-Ray Burst candidates during 20 months observation. Although many observational evidences were accumulated in past 20 years after the discovery of gamma-ray burst by LANL scientists, there are not enough evidence to determine the origin and the production mechanism of the gamma-ray burst. GBD consists of a proportional counter and a NaI scintillation counter so that it became possible to observe energy spectrum of the gamma-ray burst with high energy resolution over wide range of energy (1.5-380 keV) together with high time resolution. As the result of observation, the following facts are obtained: (1) A large fraction of observed gamma-ray bursts has a long X-ray tail after the harder part of gamma-ray emission has terminated. (2) Clear spectral absorption features with harmonic in energy was observed in some of the energy spectrum of gamma-ray bursts. These evidences support the hypothesis that the strongly magnetized neutron star is the origin of gamma-ray burst. (author)

  15. Study on changes of the plasma cytokines in 60Co γ-ray irradiated blood and leukocyte reduction of whole blood

    International Nuclear Information System (INIS)

    Li Zhiqiang; Le Jiayi; Qu Yihua; Xu Wenhao

    2006-01-01

    Objective: To study the changes of IL-2, IL-6, IFN-γ and TNF-α in 60 Co γ-ray irradiated and leukocyte reduction of whole blood, and to understand the fever phenomenon in patients received blood transfusion. Methods: ELISA method was used to measure changes of the cytokines. Results: The plasma levels of IL-2, IL-6, IFN-γ and TNF-α did not change significantly with extending the conservation period both in 60 Co-irradiated and leukocyte reduction of whole blood. The frequency of fever decreaed obviously with transfusion of 60 Co-irradiated and leukocyte reduction of whole blood. Conclusion: 60 Co-irradiated blood can not only prevent transfusion associated graft-versus-host disease (TA-GVHD), but also decrease non-hemolytic febrile transfusion reactions (NHFTR) effectively. (authors)

  16. Gamma ray astronomy from satellites and balloons

    International Nuclear Information System (INIS)

    Schoenfelder, V.

    1986-01-01

    A survey is given of gamma ray astronomy topics presented at the Cosmic Ray Conference. The major conclusions at the Cosmic Ray Conference in the field of gamma ray astronomy are given. (1) MeV-emission of gamma-ray bursts is a common feature. Variations in duration and energy spectra from burst to burst may explain the discrepancy between the measured log N - log S dependence and the observed isotropy of bursts. (2) The gamma-ray line at 1.809 MeV from Al(26) is the first detected line from a radioactive nucleosynthesis product. In order to understand its origin it will be necessary to measure its longitude distribution in the Milky Way. (3) The indications of a gamma-ray excess found from the direction of Loop I is consistent with the picture that the bulk of cosmic rays below 100 GeV is produced in galactic supernova remnants. (4) The interpretation of the large scale distribution of gamma rays in the Milky Way is controversial. At present an extragalactic origin of the cosmic ray nuclei in the GeV-range cannot be excluded from the gamma ray data. (5) The detection of MeV-emission from Cen A is a promising step towards the interesting field of extragalactic gamma ray astronomy

  17. Radiation hardness of GaAs sensors against gamma-rays, neutrons and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Šagátová, Andrea, E-mail: andrea.sagatova@stuba.sk [Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19 Bratislava (Slovakia); University Centre of Electron Accelerators, Slovak Medical University, Ku kyselke 497, 911 06 Trenčín (Slovakia); Zaťko, Bohumír; Dubecký, František [Institute of Electrical Engineering, Slovak Academy of Sciences, Dúbravská cesta 9, 841 04 Bratislava (Slovakia); Ly Anh, Tu [Faculty of Applied Science, University of Technology VNU HCM, 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City (Viet Nam); Nečas, Vladimír; Sedlačková, Katarína; Pavlovič, Márius [Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19 Bratislava (Slovakia); Fülöp, Marko [University Centre of Electron Accelerators, Slovak Medical University, Ku kyselke 497, 911 06 Trenčín (Slovakia)

    2017-02-15

    Highlights: • Radiation hardness of SI GaAs detectors against gamma-rays, neutrons and electrons was compared. • Good agreement was achieved between the experimental results and displacement damage factor of different types of radiation. • CCE and FWHM first slightly improved (by 1–8%) and just then degraded with the cumulative dose. • An increase of detection efficiency with cumulative dose was observed. - Abstract: Radiation hardness of semi-insulating GaAs detectors against {sup 60}Co gamma-rays, fast neutrons and 5 MeV electrons was compared. Slight improvements in charge collection efficiency (CCE) and energy resolution in FWHM (Full Width at Half Maximum) were observed at low doses with all kinds of radiation followed by their degradation. The effect occurred at a dose of about 10 Gy of neutrons (CCE improved by 1%, FWHM by 5% on average), at 1 kGy of electrons (FWHM decreased by 3% on average) and at 10 kGy of gamma-rays (CCE raised by 5% and FWHM dropped by 8% on average), which is in agreement with the relative displacement damage of the used types of radiation. Gamma-rays of MeV energies are 1000-times less damaging than similar neutrons and electrons about 10-times more damaging than photons. On irradiating the detectors with neutrons and electrons, we observed a global increase in their detection efficiency, which was caused probably by enlargement of the active detector area as a consequence of created radiation defects in the base material. Detectors were still functional after a dose of 1140 kGy of ∼1 MeV photons, 104 kGy of 5 MeV electrons but only up to 0.576 kGy of fast (∼2 to 30 MeV) neutrons.

  18. Gamma ray doses proceeding from natural occurring radionuclides in closed environments

    International Nuclear Information System (INIS)

    Aguiar, Vitor Angelo P. de; Medina, Nilberto H.; Silveira, Marcilei A. Guazzelli da; Moreira, Ramon H.

    2009-01-01

    In this work we report on the application of gamma-ray spectrometry in the study of the effective dose coming from terrestrial natural elements present in building materials such as sand, cement, lime (CaO) and milled granitic stones. The major contribution to annual gamma-ray radiation effective dose is due to the natural occurring radionuclides 40 K, 232 Th and 238 U. Two spectrometry systems were employed to measure the gamma radiation: one with a 60% efficient GeHP detector and the second one with a 2''x2'' NaI(Tl) scintillator. The estimated effective dose coming from the three reference rooms assumed is 0.63 mSv/yr, proceeding from terrestrial natural elements. The principal gamma radiation sources are cement, sand and bricks. (author)

  19. NEW FERMI-LAT EVENT RECONSTRUCTION REVEALS MORE HIGH-ENERGY GAMMA RAYS FROM GAMMA-RAY BURSTS

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, W. B. [Santa Cruz Institute for Particle Physics, Department of Physics and Department of Astronomy and Astrophysics, University of California at Santa Cruz, Santa Cruz, CA 95064 (United States); Baldini, L. [Universita di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bregeon, J.; Pesce-Rollins, M.; Sgro, C.; Tinivella, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bruel, P. [Laboratoire Leprince-Ringuet, Ecole polytechnique, CNRS/IN2P3, Palaiseau (France); Chekhtman, A. [Center for Earth Observing and Space Research, College of Science, George Mason University, Fairfax, VA 22030 (United States); Cohen-Tanugi, J. [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS/IN2P3, F-34095 Montpellier (France); Drlica-Wagner, A.; Omodei, N.; Rochester, L. S.; Usher, T. L. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Granot, J. [Department of Natural Sciences, The Open University of Israel, 1 University Road, P.O. Box 808, Ra' anana 43537 (Israel); Longo, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, I-34127 Trieste (Italy); Razzaque, S. [Department of Physics, University of Johannesburg, Auckland Park 2006 (South Africa); Zimmer, S., E-mail: melissa.pesce.rollins@pi.infn.it, E-mail: nicola.omodei@stanford.edu, E-mail: granot@openu.ac.il [Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm (Sweden)

    2013-09-01

    Based on the experience gained during the four and a half years of the mission, the Fermi-LAT Collaboration has undertaken a comprehensive revision of the event-level analysis going under the name of Pass 8. Although it is not yet finalized, we can test the improvements in the new event reconstruction with the special case of the prompt phase of bright gamma-ray bursts (GRBs), where the signal-to-noise ratio is large enough that loose selection cuts are sufficient to identify gamma rays associated with the source. Using the new event reconstruction, we have re-analyzed 10 GRBs previously detected by the Large Area Telescope (LAT) for which an X-ray/optical follow-up was possible and found four new gamma rays with energies greater than 10 GeV in addition to the seven previously known. Among these four is a 27.4 GeV gamma ray from GRB 080916C, which has a redshift of 4.35, thus making it the gamma ray with the highest intrinsic energy ({approx}147 GeV) detected from a GRB. We present here the salient aspects of the new event reconstruction and discuss the scientific implications of these new high-energy gamma rays, such as constraining extragalactic background light models, Lorentz invariance violation tests, the prompt emission mechanism, and the bulk Lorentz factor of the emitting region.

  20. Relative biological efficiency of intermediate energy neutrons and 60Co rays for induction of chromosomal aberrations in Chinese hamster fibroblasts

    International Nuclear Information System (INIS)

    Sturelid, S.; Bergman, R.

    1976-01-01

    Intermediate energy neutrons are unique in that a considerable fraction of critical interactions and of dose absorbed is not associated with ionization but with atomic collision. It is still unknown to what extent the qualitative difference in primary damage after atomic collision compared to that of ionization and excitation becomes expressed at biological levels. Chromosomal aberrations were studied in Chinese hamster fibroblasts exposed for 5-8 hours at 22 degree C to intermediate energy neutrons, mean energy 8.5 keV, or to 60 Co-gamma rays. RBE at the 10 per cent aberration frequency level in S-phase were 2.2+-0.6 for total aberrations, 2.1+-0.6 for chromatid breaks and 1.8+-0.5 for exchanges. For each chromatid aberration observed after recovery, about 200 bondbreaking atomic collisions besides 3000 primary iniozations should have occured in DNA. However, the extent to which the aberration response is due to atomic collisions is not clear. (author)

  1. A comparison of the survival (LD/sub 50/30/) of a number of inbred mouse strains after X and 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Vacha, J.; Znojil, V.; Hola, J.; Sikulova, J.

    1984-01-01

    The value of LD/sub 50/30/ for X and 60 Co gamma radiation was ascertained for several inbred mouse strains and the significance of interstrain differences in these parameters determined. The rank order of strains according to LD/sub 50/30/ differs as between the two types of radiation with the exception of the strains BALB/c and B10.LP/Ph, which are the least resistant to radiation-induced lethality with both types of radiation. The strain C57BL/10ScSnPh is highly resistant to X irradiation. The relative biological effectiveness of 60 Co gamma radiation as compared with X-radiation from the point of view of lethality fluctuates between 0.748 and 0.952 in individual strains, with a mean value of 0.866 +- 0.033. The RBE values do not correlate with the radiosensitivity of the strain, but they do correlate with the relative contribution to erythropoiesis of the spleen. (author)

  2. Comparison of the survival (LD/sub 50/30/) of a number of inbred mouse strains after X and /sup 60/Co gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Vacha, J.; Znojil, V.; Hola, J.; Sikulova, J. (Ceskoslovenska Akademie Ved, Brno. Biofysikalni Ustav)

    1984-01-01

    The value of LD/sub 50/30/ for X and /sup 60/Co gamma radiation was ascertained for several inbred mouse strains and the significance of interstrain differences in these parameters determined. The rank order of strains according to LD/sub 50/30/ differs as between the two types of radiation with the exception of the strains BALB/c and B10.LP/Ph, which are the least resistant to radiation-induced lethality with both types of radiation. The strain C57BL/10ScSnPh is highly resistant to X irradiation. The relative biological effectiveness of /sup 60/Co gamma radiation as compared with X-radiation from the point of view of lethality fluctuates between 0.748 and 0.952 in individual strains, with a mean value of 0.866 +- 0.033. The RBE values do not correlate with the radiosensitivity of the strain, but they do correlate with the relative contribution to erythropoiesis of the spleen.

  3. Radiolysis of titanium potassium oxalate in aqueous solution. [. gamma. rays

    Energy Technology Data Exchange (ETDEWEB)

    Bundo, Y; Ono, I [Industrial Research Inst. of Kanagawa Prefecture, Yokohama (Japan); Ogawa, T

    1975-01-01

    The dissolution state of titanium potassium oxalate in aqueous solution is different according to the pH. The yellowish brown titanium complex produced by the reaction of titanium potassium oxalate and hydrogen peroxide seems to be different in its structure according to the pH. Considering these points, gamma-ray irradiation was carried out on the sample by dissolving titanium potassium oxalate in purified water under the conditions of oxygen saturation and nitrogen saturation, and the relation between irradiation dose and the production of titanium complex was determined. On the basis of the experimental result, the mechanism of forming hydrogen peroxide was presumed. The radiation source used was 2,000 Ci of /sup 60/Co. For photometric analysis, a 139 type photoelectric spectrophotometer of Hitachi Ltd. was used. From the experimental results, in neutral water, titanium potassium oxalate exists in the state that two oxalic acid ions are coordinated to titanyl ion, while in case of the pH lowered by the addition of sulfuric acid, it can exist in the state that one oxalic acid ion is coordinated to titanyl ion. The yield of hydrogen peroxide produced by irradiating titanium potassium oxalate aqueous solution with gamma-ray is the sum of the molecular product from water and the radiolysis product from titanium potassium oxalate.

  4. Effects of 60Co γ-rays irradiation on cell growth and alkaloid accumulation of protocorm-like bodies in suspension cultures from Dendrobium huoshanense

    International Nuclear Information System (INIS)

    Hong Sali; Jin Qing; Huang Bei; Cai Yongping; Lin Yi

    2009-01-01

    Protocorm-like bodies (PLBs) in suspension cultures from Dendrobium huoshanense were irradiated by 60 Co γ-rays at doses of 5, 10, 20 and 30Gy, and alkaloid accumulation of PLBs was studied. The results showed that 60 Co γ-rays irradiation could improve the alkaloid content of PLBs, and the suitable dose was 10Gy. The fresh weight of 10Gy irradiated PLBs was 26.54g/flask, and the alkaloid content was 0.035% on the 36th day. The medium pH and electric conductivity of 10Gy irradiated PLBs changed slightly during the suspension culture period. The results suggested such cultural environment was suitable for PLBs growth continuely. Results also showed that 60 Co γ-rays irradiation could increase the activities of POD, SOD, CAT, PAL and decrease the activity of PPO, these were responsible for the improvement of cell growth and alkaloid accumulation in PLBs. (authors)

  5. Processing of gamma-ray spectrometric logs

    International Nuclear Information System (INIS)

    Umiastowski, K.; Dumesnil, P.

    1984-10-01

    CEA (Commissariat a l'Energie Atomique) has developped a gamma-ray spectrometric tool, containing an analog-to-digital converter. This new tool permits to perform very precise uranium logs (natural gamma-ray spectrometry), neutron activation logs and litho-density logs (gamma-gamma spectrometric logs). Specific processing methods were developped to treate the particular problems of down-hole gamma-ray spectrometry. Extraction of the characteristic gamma-ray peak, even if they are superposed on the background radiation of very high intensity, is possible. This processing methode enables also to obtain geological informations contained in the continuous background of the spectrum. Computer programs are written in high level language for SIRIUS (VICTOR) and APOLLO computers. Exemples of uranium and neutron activation logs treatment are presented [fr

  6. A link between prompt optical and prompt gamma-ray emission in gamma-ray bursts.

    Science.gov (United States)

    Vestrand, W T; Wozniak, P R; Wren, J A; Fenimore, E E; Sakamoto, T; White, R R; Casperson, D; Davis, H; Evans, S; Galassi, M; McGowan, K E; Schier, J A; Asa, J W; Barthelmy, S D; Cummings, J R; Gehrels, N; Hullinger, D; Krimm, H A; Markwardt, C B; McLean, K; Palmer, D; Parsons, A; Tueller, J

    2005-05-12

    The prompt optical emission that arrives with the gamma-rays from a cosmic gamma-ray burst (GRB) is a signature of the engine powering the burst, the properties of the ultra-relativistic ejecta of the explosion, and the ejecta's interactions with the surroundings. Until now, only GRB 990123 had been detected at optical wavelengths during the burst phase. Its prompt optical emission was variable and uncorrelated with the prompt gamma-ray emission, suggesting that the optical emission was generated by a reverse shock arising from the ejecta's collision with surrounding material. Here we report prompt optical emission from GRB 041219a. It is variable and correlated with the prompt gamma-rays, indicating a common origin for the optical light and the gamma-rays. Within the context of the standard fireball model of GRBs, we attribute this new optical component to internal shocks driven into the burst ejecta by variations of the inner engine. The correlated optical emission is a direct probe of the jet isolated from the medium. The timing of the uncorrelated optical emission is strongly dependent on the nature of the medium.

  7. Stellar Sources of Gamma-ray Bursts

    OpenAIRE

    Luchkov, B. I.

    2011-01-01

    Correlation analysis of Swift gamma-ray burst coordinates and nearby star locations (catalog Gliese) reveals 4 coincidences with good angular accuracy. The random probability is 4\\times 10^{-5}, so evidencing that coincident stars are indeed gamma-ray burst sources. Some additional search of stellar gamma-ray bursts is discussed.

  8. Ambient-temperature diffusion and gettering of Pt atoms in GaN with surface defect region under 60Co gamma or MeV electron irradiation

    Science.gov (United States)

    Hou, Ruixiang; Li, Lei; Fang, Xin; Xie, Ziang; Li, Shuti; Song, Weidong; Huang, Rong; Zhang, Jicai; Huang, Zengli; Li, Qiangjie; Xu, Wanjing; Fu, Engang; Qin, G. G.

    2018-01-01

    Generally, the diffusion and gettering of impurities in GaN needs high temperature. Calculated with the ambient-temperature extrapolation value of the high temperature diffusivity of Pt atoms in GaN reported in literature, the time required for Pt atoms diffusing 1 nm in GaN at ambient temperature is about 19 years. Therefore, the ambient-temperature diffusion and gettering of Pt atoms in GaN can hardly be observed. In this work, the ambient-temperature diffusion and gettering of Pt atoms in GaN is reported for the first time. It is demonstrated by use of secondary ion mass spectroscopy that in the condition of introducing a defect region on the GaN film surface by plasma, and subsequently, irradiated by 60Co gamma-ray or 3 MeV electrons, the ambient-temperature diffusion and gettering of Pt atoms in GaN can be detected. It is more obvious with larger irradiation dose and higher plasma power. With a similar surface defect region, the ambient-temperature diffusion and gettering of Pt atoms in GaN stimulated by 3 MeV electron irradiation is more marked than that stimulated by gamma irradiation. The physical mechanism of ambient-temperature diffusion and gettering of Pt atoms in a GaN film with a surface defect region stimulated by gamma or MeV electron irradiation is discussed.

  9. Resposta de sementes de amendoim a diferentes doses de radiação gama (60Co Response of peanut seeds to different levels of gamma radiation (60Co

    Directory of Open Access Journals (Sweden)

    Tatiana da S. Santos

    2010-10-01

    Full Text Available A radiação gama, proveniente da fonte de 60Co, é bastante utilizada para esterilização, visando a prevenção da decomposição e a toxidez de origem microbiana em diversos produtos. O grau de radiossensibilidade de um embrião vegetal depende da espécie, do estágio de seu desenvolvimento durante a radiação, da dose empregada e do critério usado para medir o efeito biológico, sendo comumente utilizado o teste de germinação. Objetivou-se, com este trabalho, estudar a sensibilidade do amendoim a radiação gama e seus efeitos na germinação, no vigor e na micoflora das sementes da cultivar BRS Havana, irradiadas com uma fonte de 60Co, tipo gammacell, com taxa de dosagem de 12,5 kGy h-1. As doses testadas em kGy foram as seguintes: 0; 0,5; 1,0; 1,5; 2,0; 2,5; 3,0; 6,0; 9,0; 12,0; 15,0; 18,0; 21,0 e 24,0. Com os resultados obtidos, concluiu-se que as doses acima de 3,0 kGy prejudicaram a viabilidade das sementes e as doses acima de 12 kGy comprometeram totalmente o vigor e a germinação das sementes de amendoim. A radiação a partir da dose 2,0 kGy eliminou os fungos Aspergillus flavus e Aspergillus niger e, a partir da dose 3,0 kGy, eliminou o Aspergillus glaucus. O Penicilium spp. permaneceu em mais de 30% das sementes em todos os tratamentos com radiação, não sendo eliminado até a dose de 24 kGy.The gamma radiation from 60Co source is widely used for sterilization aiming at preventing decomposition and toxicity from microbes in several products. The degree of radiosensitvity of a plant embryo depends on the species, the development stage during radiation, doses used and the criteria used to measure the biological effect, the germination test, being commonly used.This work aimed to study the peanut sensitivity to gamma radiation and its effects in the germination, in the vigour and seeds microflora of cultivar BRS Havana, irradiated with 60Co source, type gammacell with rate of dosage of 12.5 kGy h-1. The tested doses were the

  10. Efficiency and effectiveness of gamma rays and sodium azide in Sesbania cannabina Poir

    International Nuclear Information System (INIS)

    Kumar, G.; Srivastava, N.

    2013-01-01

    Mutagenic effectiveness and efficiency is an important factor for the selection of a mutagen for a mutation breeding program. Mutagenic effectiveness is a measure of the frequency of mutations induced by a unit mutagen dose, while mutagenic efficiency is a measure of the proportion of mutations in relation to undesirable changes such as lethality, sterility, meiotic aberrations etc. The present study envisages the mutagenic effectiveness and efficiency of individual and combined treatments of chemical and physical mutagens i.e. sodium azide (individual), gamma rays (individual) and sodium azide + gamma ray (combined). For the individual treatment of sodium azide, the seeds of the Sesbania cannabina variety ND-1 were treated with 0.5% solution of sodium azide (SA) for four different time durations, i.e. 3, 5, 7, and 9 h, and for the individual treatment of gamma rays, dry and healthy seeds were treated with 20, 40, 60, and 80 Kr doses of gamma rays. For the combined treatment, the seeds were exposed to four different doses of gamma rays (20, 40, 60, and 80 Kr) and after irradiation seeds were treated with 0.5% solution of sodium azide for 3 h. After treatment, seeds subjected to individual and combined treatment were sown in randomized block design to raise the M 1 generation and a study was conducted on germination percentage, survival percentage, pollen fertility percentage, and chromosomal aberrations at different doses of the individual and combined treatments. (author)

  11. Effects of gamma rays on rat vascular smooth muscle fibers

    Energy Technology Data Exchange (ETDEWEB)

    Ghassan, A [Radio-Biology and Health Dept. Syrian Atomic Energy Commission, (Syrian Arab Republic)

    1995-10-01

    Modifications of the Vasomotoricity induced by gamma rays have been investigated. Vascular smooth muscle fibres (VSMF) of rat portal vein have been used in this study. Irradiation procedures using a {sup 60} Co source have been carried out as follows: - Whole body irradiation. - Irradiation of isolated portal vein and isolated VSMF. Our results show that : 1-irradiation reduces the functional competition between Mg{sup 2+} and Ca{sup 2+}, thus hyper magnetic Krebs solutions have a negligible effect on irradiated VSMF. 2- irradiation activates Ca{sup 2+} influx into the VSMF. Thus the effect of hypocalcemic solutions on irradiated VSMF is minor compared with control. 3- Hyperpotassic solutions provoke titanic contractions with high amplitude on the irradiated VSMF compared with control. 5 figs.

  12. Physical constraints on models of gamma-ray bursters

    International Nuclear Information System (INIS)

    Epstein, R.I.

    1985-01-01

    This report deals with the constraints that can be placed on models of gamma-ray burst sources based on only the well-established observational facts and physical principles. The premise is developed that the very hard x-ray and gamma-ray continua spectra are well-established aspects of gamma-ray bursts. Recent theoretical work on gamma-ray bursts are summarized with emphasis on the geometrical properties of the models. Constraints on the source models which are implied by the x-ray and gamma-ray spectra are described. The allowed ranges for the luminosity and characteristic dimension for gamma-ray burst sources are shown. Some of the deductions and inferences about the nature of the gamma-ray burst sources are summarized. 67 refs., 3 figs

  13. EGRET observations of diffuse gamma-ray emission in taurus and perseus

    International Nuclear Information System (INIS)

    Digel, Seth W.; Grenier, Isabelle A.

    2001-01-01

    We present an analysis of the interstellar gamma-ray emission observed toward the extensive molecular cloud complexes in Taurus and Perseus by the Energetic Gamma-Ray Experiment Telescope (EGRET). The region's large size (more than 300 square degrees) and location below the plane in the anticenter are advantageous for straightforward interpretation of the interstellar emission. The complex of clouds in Taurus has a distance of ∼140 pc and is near the center of the Gould Belt. The complex in Perseus, adjacent to Taurus on the sky, is near the rim of the Belt at a distance of ∼300 pc. The findings for the cosmic-ray density and the molecular mass-calibrating ratio N(H 2 )/W CO in Taurus and Perseus are compared with results for other nearby cloud complexes resolved by EGRET. The local clouds that now have been studied in gamma rays can be used to trace the distribution of high-energy cosmic rays within 1 kpc of the sun

  14. Microwave-gamma ray water in crude monitor

    International Nuclear Information System (INIS)

    Paap, H.J.

    1984-01-01

    A microwave-gamma ray water-in-crude monitoring system measures the percent quantity of fresh water or salt water in crude oil flowing in a pipe line. The system includes a measuring cell arranged with the pipe line so that the crude oil flows through the measuring cell. A microwave transmitter subsystem and a gamma ray source are arranged with the measuring cell so that microwave energy and gamma rays are transmitted through the measuring cell. A microwave receiving subsystem and a gamma ray detector provide signals corresponding to received microwave energy and to the received gamma rays, respectively. Apparatus connected to the microwave receiver and to the gamma ray detector provides an indication of the percentage of water in the crude oil

  15. Remote planetary geochemical exploration with the NEAR X-ray/gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Trombka, J.I.; Boynton, W.V.; Brueckner, J.; Squyres, S.; Clark, P.E.; Starr, R.; Evans, L.G.; Floyd, S.R.; McClanahan, T.P.; Goldsten, J.; Mcnutt, R.; Schweitzer, J.S.

    1999-01-01

    The X-ray/gamma-ray spectrometer (XGRS) instrument onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft will map asteroid 433 Eros in the 0.2 keV to 10 MeV energy region. Measurements of the discrete line X-ray and gamma-ray emissions in this energy domain can be used to obtain both qualitative and quantitative elemental composition maps of the asteroid surface. The NEAR X-ray/gamma-ray spectrometer (XGRS) was turned on for the first time during the week of 7 April 1996. Rendezvous with Eros 433 is expected during December 1998. Observations of solar X-ray spectra during both quiescent and active periods have been made. A gamma-ray transient detection system has been implemented and about three gamma-ray transient events a week have been observed which are associated with either gamma-ray bursts or solar flares

  16. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  17. Recent results on celestial gamma radiation from SMM

    Science.gov (United States)

    Share, Gerald H.

    1991-01-01

    Observations made by the Gamma Ray Spectrometer on board the SMM are described. Recent results reported include observations and analyses of gamma-ray lines from Co-56 produced in supernovae, observations of the temporal variation of the 511 keV line observed during Galactic center transits, and measurements of the diffuse Galactic spectrum from 0.3 to 8.5 MeV. The work in progress includes measurements of the distribution of Galactic Al-26, observations to place limits on Galactic Ti-44 and Fe-60 and on Be-7 produced in novae, and searches for a characteristic gamma-ray emission from pair plasmas, a 2.223 MeV line emission, limits on deexcitation lines from interstellar C and O, and gamma-ray bursts.

  18. Multifrequency Observations of Gamma-Ray Burst

    OpenAIRE

    Greiner, J.

    1995-01-01

    Neither a flaring nor a quiescent counterpart to a gamma-ray burst has yet been convincingly identified at any wavelength region. The present status of the search for counterparts of classical gamma-ray bursts is given. Particular emphasis is put on the search for flaring counterparts, i.e. emission during or shortly after the gamma-ray emission.

  19. Gamma-rays from deep inelastic collisions

    International Nuclear Information System (INIS)

    Stephens, F.S.

    1981-01-01

    My objective in this talk is to consider the question: 'What can be learned about deep inelastic collisions (DIC) from studying the associated gamma-rays'. First, I discuss the origin and nature of the gamma-rays from DIC, then the kinds of information gamma-ray spectra contain, and finally come to the combination of these two subjects. (orig./HSI)

  20. Soft x-ray emission from gamma-ray bursts observed with ginga

    International Nuclear Information System (INIS)

    Yoshida, Atsumasa; Murakami, Toshio; Itoh, Masayuki

    1989-01-01

    The soft X-ray emission of gamma-ray bursts below 10 keV provides information about size, location, and emission mechanism. The Gamma-ray Burst Detector (GBD) on board Ginga, which consists of a proportional counter and a scintillation detector, covers an energy range down to 1.5 keV with 63 cm 2 effective area. In several of the observed gamma-ray bursts, the intensity of the soft X-ray emission showed a longer decay time of 50 to 100s after the higher energy gamma-ray emission had ended. Although we cannot rule out other models, such as bremsstrahlung and thermal cyclotron types, due to poor statistics, the soft X-ray spectra are consistent with a blackbody of 1 to 2 keV in the late phase of the gamma-ray bursts. This enables us to estimate the size of the blackbody responsible for the X-ray emission. (author)

  1. Effect of single and combined treatment with gamma rays and some chemical mutagens in rice

    International Nuclear Information System (INIS)

    Lyong Van Hin; Mekhandzhiev, A.; Murzova, P.; Chilikov, I.

    1991-01-01

    Dry rice seeds of 3 cvs and 2 lines have been irradiated (Co 60 , 10 krad) and treated with 0.0012% sodium azide (NaN 3 ) and 0.2% ethylmethanesulfonate (EMS) in definite combinations. It is found that chlorophyll mutations are less frequent after single gamma irradiation. Sodium azide produces a higher percentage of mutations than EMS. Highest mutation frequency has been observed following combined treatment with gamma rays and chemical mutagens. The combined treatment has resulted in a considerably higher mutation effect than the theoretically expected one in the lines Nora and Mega, and in cv. Krasnodarski 424. Highest mutation spectrum has been found in cv. Krasnodarski 424 and in Nora line following combined treatment. 1 tab., 5 figs., 20 refs

  2. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  3. Solid state structural investigations of the bis(chalcone) compound with single crystal X-ray crystallography, DFT, gamma-ray spectroscopy and chemical spectroscopy methods

    Science.gov (United States)

    Yakalı, Gül; Biçer, Abdullah; Eke, Canel; Cin, Günseli Turgut

    2018-04-01

    A bis(chalcone), (2E,6E)-2,6-bis((E)-3phenylallidene)cyclohexanone, was characterized by 1H NMR, 13C NMR, FTIR, UV-Vis spectroscopy, gamma-ray spectroscopy and single crystal X- ray structural analysis. The optimized molecular structure of the compound is calculated using DFT/B3LYP with 6-31G (d,p) level. The calculated geometrical parameters are in good agreement with the experimental data obtained from our reported X-ray structure. The powder and single crystal compounds were gama-irradiated using clinical electron linear accelerator and 60Co gamma-ray source, respectively. Spectral studies (1H NMR, 13C NMR, FTIR and UV-Vis) of powder chalcone compound were also investigated before and after irradiation. Depending on the irradiation notable changes were observed in spectral features powder sample. Single crystal X-ray diffraction investigation shows that both unirradiated and irradiated single crystal samples crystallizes in a orthorhombic crystal system in the centrosymmetric space group Pbcn and exhibits an C-H..O intramolecular and intermolecular hydrogen bonds. The crystal packing is stabilised by strong intermolecular bifurcate C-H..O hydrogen bonds and π…π stacking interactions. The asymmetric unit of the title compound contains one-half of a molecule. The other half of the molecule is generated with (1-x,y,-3/2-z) symmetry operator. The molecule is almost planar due to having π conjugated system of chalcones. However, irradiated single crystal compound showed significant changes lattice parameters, crystal volume and density. According to results of gamma-ray spectroscopy, radioactive elements of powder compound which are 123Sb(n,g),124Sb,57Fe(g,p),56Mn, 55Mn(g,n), and 54Mn were determined using photoactivation analysis. However, the most intensive gamma-ray energy signals are 124Sb.

  4. Gamma-ray Output Spectra from 239 Pu Fission

    International Nuclear Information System (INIS)

    Ullmann, John

    2015-01-01

    Gamma-ray multiplicities, individual gamma-ray energy spectra, and total gamma energy spectra following neutron-induced fission of 239 Pu were measured using the DANCE detector at Los Alamos. Corrections for detector response were made using a forward-modeling technique based on propagating sets of gamma rays generated from a paramaterized model through a GEANT model of the DANCE array and adjusting the parameters for best fit to the measured spectra. The results for the gamma-ray spectrum and multiplicity are in general agreement with previous results, but the measured total gamma-ray energy is about 10% higher. A dependence of the gamma-ray spectrum on the gamma-ray multplicity was also observed. Global model calculations of the multiplicity and gamma energy distributions are in good agreement with the data, but predict a slightly softer total-energy distribution

  5. Effects of different premature chromosome condensation method on dose-curve of 60Co γ-ray

    International Nuclear Information System (INIS)

    Guo Yicao; Yang Haoxian; Yang Yuhua; Li Xi'na; Huang Weixu; Zheng Qiaoling

    2012-01-01

    Objective: To study the effect of traditional method and improved method of the premature chromosome condensation (PCC) on the dose-effect curve of 60 Co γ ray, for choosing the rapid and accurate biological dose estimating method for the accident emergency. Methods: Collected 3 healthy male cubits venous blood (23 to 28 years old), and irradiated by 0, 1.0, 5.0, 10.0, 15.0, 20.0 Gy 60 Co γ ray (absorbed dose rate: 0.635 Gy/min). Observed the relation of dose-effect curve in the 2 incubation time (50 hours and 60 hours) of the traditional method and improved method. Used the dose-effect curve to verify the exposure of 10.0 Gy (absorbed dose rate: 0.670 Gy/min). Results: (1) In the traditional method of 50-hour culture, the PCC cell count in 15.0 Gy and 20.0 Gy was of no statistical significance. But there were statistical significance in the traditional method of 60-hours culture and improved method (50-hour culture and 60-hour culture). Used the last 3 culture methods to make dose curve. (2) In the above 3 culture methods, the related coefficient between PCC ring and exposure dose was quite close (all of more than 0.996, P 0.05), the morphology of regression straight lines almost overlap. (3) Used the above 3 dose-effect curves to estimate the irradiation results (10.0 Gy), the error was less than or equal to 8%, all of them were within the allowable range of the biological experiment (15%). Conclusion: The 3 dose-effect curves of the above 3 culture methods can apply to biological dose estimating of large doses of ionizing radiation damage. Especially the improved method of 50-hour culture,it is much faster to estimate and it should be regarded as the first choice in accident emergency. (authors)

  6. X-ray and. gamma. -ray sources: a comparison of their characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Freund, A K [Institut Max von Laue - Paul Langevin, 38 - Grenoble (France)

    1979-11-01

    A comparison of the various source characteristics, in particular the available fluxes of radiation in the X-ray/..gamma..-ray region from (1) high power rotary anode X-ray generators, (2) radioactive ..gamma..-ray sources and (3) high energy electron storage rings is presented. Some of the specific characteristics and possible applications of synchrotron radiation as a source are discussed in detail, together with problems associated with the monochromatization of the continuous radiation in the X-ray/..gamma..-ray region. The new high energy machines PEP at Stanford, the 8 GeV storage ring CESR at Cornell and the PETRA storage ring in Hamburg, which will soon come into operation provide a spectrum of high intensity radiation reaching well above h..gamma..sub(photon)=100 keV. The possibilities of using ondulators (wigglers), and laser-electron scattering for constructing high repetition rate tunable ..gamma..-ray sources are also discussed. Finally the potentials of using the powerful spontaneous emission of ..gamma..-quanta by relativistic channeled particles are mentioned.

  7. A DETAILED STUDY OF THE MOLECULAR AND ATOMIC GAS TOWARD THE {gamma}-RAY SUPERNOVA REMNANT RX J1713.7-3946: SPATIAL TeV {gamma}-RAY AND INTERSTELLAR MEDIUM GAS CORRESPONDENCE

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Y.; Sano, H.; Sato, J.; Torii, K.; Horachi, H.; Hayakawa, T.; Inutsuka, S.; Kawamura, A.; Yamamoto, H.; Okuda, T.; Mizuno, N.; Onishi, T. [Department of Physics and Astrophysics, Nagoya University, Nagoya, Aichi 464-8601 (Japan); McClure-Griffiths, N. M. [CSIRO Astronomy and Space Science, Epping NSW 1710 (Australia); Rowell, G. [School of Chemistry and Physics, University of Adelaide, Adelaide 5005 (Australia); Inoue, T. [Department of Physics and Mathematics, Aoyama Gakuin University, Sagamihara, Kanagawa 252-5258 (Japan); Mizuno, A. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya, Aichi 464-8601 (Japan); Ogawa, H., E-mail: fukui@a.phys.nagoya-u.ac.jp [Department of Astrophysics, Graduate School of Science, Osaka Prefecture University, Sakai, Osaka 599-8531 (Japan)

    2012-02-10

    RX J1713.7-3946 is the most remarkable TeV {gamma}-ray supernova remnant (SNR) that emits {gamma}-rays in the highest energy range. We have made a new combined analysis of CO and H I in the SNR and derived the total protons in the interstellar medium (ISM). We have found that the inclusion of the H I gas provides a significantly better spatial match between the TeV {gamma}-rays and ISM protons than the H{sub 2} gas alone. In particular, the southeastern rim of the {gamma}-ray shell has a counterpart only in the H I. The finding shows that the ISM proton distribution is consistent with the hadronic scenario that cosmic-ray (CR) protons react with ISM protons to produce the {gamma}-rays. This provides another step forward for the hadronic origin of the {gamma}-rays by offering one of the necessary conditions missing in the previous hadronic interpretations. We argue that the highly inhomogeneous distribution of the ISM protons is crucial in the origin of the {gamma}-rays. Most of the neutral gas was likely swept up by the stellar wind of an OB star prior to the supernova (SN) explosion to form a low-density cavity and a swept-up dense wall. The cavity explains the low-density site where the diffusive shock acceleration of charged particles takes place with suppressed thermal X-rays, whereas the CR protons can reach the target protons in the wall to produce the {gamma}-rays. The present finding allows us to estimate the total CR proton energy to be {approx}10{sup 48} erg, 0.1% of the total energy of the SN explosion.

  8. Correlation between Co-60 and X-ray exposures on radiation-induced charge buildup in silicon-on-insulator buried oxides

    International Nuclear Information System (INIS)

    Schwank, James R.; Shaneyfelt, Marty R.; Loemker, Rhonda Ann; Draper, Bruce L.; Dodd, Paul E.; Witczak, StevenN C.; Riewe, Leonard Charles; Ferlet-Cavrois, V.; Paillet, P.; Leray, J.-L.; Fleetwood, D.M.

    2000-01-01

    Large differences in charge buildup in SOI buried oxides can result between x-ray and Co-60 irradiations. The effects of bias configuration and substrate type on charge buildup and hardness assurance issues are explored

  9. Gamma-Ray Bursts

    Science.gov (United States)

    Pellizza, L. J.

    Gamma-ray bursts are the brightest transient sources in the gamma-ray sky. Since their discovery in the late 1960s, the investigation of the astrophysical sys- tems in which these phenomena take place, and the physical mechanisms that drive them, has become a vast and prolific area of modern astrophysics. In this work I will briefly describe the most relevant observations of these sources, and the models that describe their nature, emphasizing on the in- vestigations about the progenitor astrophysical systems. FULL TEXT IN SPANISH

  10. Establishing the estimation model on radiation level at the ambience of 60Co radiotherapy treatment room based on NCRP REPORT No.151

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Yu Shui

    2009-01-01

    Objective: To establish the estimation model to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. Methods: The estimation model derives from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities b y making appropriate adjustment, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The application scope of estimation model from NCRP REPORT No.151 is extended to γ-radiotherapy facilities, and it can be regarded as a new model for calculating the radiation level at the ambience of 60 Co radiotherapy treatment room. Conclusion: The estimation model has certain reference value to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. (authors)

  11. Design and Performance of the GAMMA-400 Gamma-Ray Telescope for Dark Matter Searches

    Science.gov (United States)

    Galper, A. M.; Adriani, O.; Aptekar, R. L.; Arkhangelskaja, I. V.; Arkhangelskiy, A. I.; Boezio, M.; Bonvicini, V.; Boyarchuk, K. A.; Fradkin, M. I.; Gusakov, Yu V.; hide

    2012-01-01

    The GAMMA-400 gamma-ray telescope is designed to measure the fluxes of gamma-rays and cosmic-ray electrons (+) positrons, which can be produced by annihilation or decay of the dark matter particles, as well as to survey the celestial sphere in order to study point and extended sources of gamma-rays, measure energy spectra of Galactic and extragalactic diffuse gamma-ray emission, gamma-ray bursts, and gamma-ray emission from the Sun. GAMMA-400 covers the energy range from 100 MeV to 3000 GeV. Its angular resolution is approximately 0.01deg (E(sub gamma) greater than 100 GeV), the energy resolution approximately 1% (E(sub gamma) greater than 10 GeV), and the proton rejection factor approximately 10(exp 6). GAMMA-400 will be installed on the Russian space platform Navigator. The beginning of observations is planned for 2018.

  12. Gamma rays, tracers of the interstellar medium and messengers of pulsars and other energetic objects

    International Nuclear Information System (INIS)

    Grenier, I.

    1988-03-01

    Gamma radiation observed in our Galaxy by the COS-B satellite was studied. The interstellar medium was studied at large scale using the fact that diffuse gamma rays are created by the interaction of cosmic rays with any interstellar matter and comparisons with different tracers and star and galaxy counts. Ground-based maps of molecular clouds were also used. Bright compact gamma sources were also analyzed. Results include the detection in Co of a distant spiral arm of the Galaxy (15kpc) and an important molecular complex nearby (300pc); the first Co survey of the Galaxy; measurement of the NH2/WCo ratio and week galactic gradients of cosmic rays; the high energy behavior of the Vela pulsar; the detection of a gamma source; and the discovery of a large supernova remnant which exploded 300pc from the Sun 40,000 years ago [fr

  13. Thermal neutron capture gamma-rays

    International Nuclear Information System (INIS)

    Tuli, J.K.

    1983-01-01

    The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,α), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,#betta#) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide

  14. Temperature dependence of luminescence from silica glasses under in-reactor and 60Co gamma-ray irradiation

    Science.gov (United States)

    Takahara, Shogo; Yoshida, Tomoko; Tanabe, Tetuo; , Tatuya, Ii; Hirano, Masahiro; Okada, Moritami

    2004-06-01

    In order to investigate the temperature effects on the dynamic radiation damaging process, we have carried out in situ measurements of in-reactor luminescence (IRL) and gamma-ray induced luminescence (GIL) of a silica glass at temperatures ranging from 70 K to 370 K. Both luminescence spectra were found to consist of two broad emission centers at 3.1 eV and 4.1 eV with an additional temperature independent emission around 2.5 eV. The 2.5 eV emission different from the other two showed long tail to the lower energy side and was attributed to the Cherenkov radiation. The 3.1 eV band was attributed to a B 2 β oxygen deficient center on the basis of our photoluminescence measurement. The intensity of the 3.1 eV IRL increased with increasing temperature up to ca. 200 K and saturated above 200 K, which is clearly different from the reported temperature dependence of 3.1 eV photoluminescence, suggesting the existence of some different relaxation mechanism of excited electron under ionizing radiations.

  15. The Animated Gamma-ray Sky Revealed by the Fermi Gamma-ray Space Telescope

    International Nuclear Information System (INIS)

    Grenier, Isabelle

    2009-01-01

    The Fermi Gamma-ray Space Telescope has been observing the sky in gamma-rays since August 2008. In addition to breakthrough capabilities in energy coverage (20 MeV-300 GeV) and angular resolution, the wide field of view of the Large Area Telescope enables observations of 20% of the sky at any instant, and of the whole sky every three hours. It has revealed a very animated sky with bright gamma-ray bursts flashing and vanishing in minutes, powerful active galactic nuclei flaring over hours and days, many pulsars twinkling in the Milky Way, and X-ray binaries shimmering along their orbit. Most of these variable sources had not been seen by the Fermi predecessor, EGRET, and the wealth of new data already brings important clues to the origin of the high-energy emission and particles powered by the compact objects. The telescope also brings crisp images of the bright gamma-ray emission produced by cosmic-ray interactions in the interstellar medium, thus allowing to measure the cosmic nuclei and electron spectra across the Galaxy, to weigh interstellar clouds, in particular in the dark-gas phase. The telescope sensitivity at high energy will soon provide useful constraints on dark-matter annihilations in a variety of environments. I will review the current results and future prospects of the Fermi mission.

  16. Eradication of sweet potato weevil using Co-60 gamma radiation

    International Nuclear Information System (INIS)

    Tokunaga, Taizo

    2007-01-01

    Sweet potato weevil which is a harmful insect injuring sweet potatoes was found out at Yoron Island in 1915 for the first time in Kagoshima prefecture, Japan. Here the eradication of sweet potato weevils using cobalt 60 irradiation achieved at Kikai Island is described. The mass-reared male weevils in potatoes are in pasture after sterilized by gamma irradiation. If the sexually sterile male copulates with a wild female, the egg does not incubate. By the repeated sterilization during several generations, the eradication of sweet potato weevils was accomplished. (M.H.)

  17. GEM gas detectors for soft X-ray imaging in fusion devices with neutron–gamma background

    Energy Technology Data Exchange (ETDEWEB)

    Pacella, Danilo, E-mail: danilo.pacella@enea.it [Associazione EURATOM-ENEA, C.R. Frascati, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Romano, Afra; Gabellieri, Lori [Associazione EURATOM-ENEA, C.R. Frascati, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Murtas, Fabrizio [Istituto Nazionale di Fisica Nucleare, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Mazon, Didier [Association EURATOM-CEA, CEA Cadarache, DSM/IRFM, 13108 St. Paul Lez Durance Cedex (France)

    2013-08-21

    A triple gas electron multiplier (GEM) detector has been built and characterized in a collaboration between ENEA, INFN and CEA to develop a soft X-ray imaging diagnostic for magnetic fusion plasmas. It has an active area of 5×5 cm{sup 2}, 128 pixels and electronics in counting mode. Since burning plasma experiments will have a very large background of radiation, this prototype has been tested with contemporary X-ray, neutron and gamma irradiation, to study the detection efficiencies, and the discrimination capabilities. The detector has been preliminarily characterized under DD neutron irradiation (2.45 MeV) up to 2.2×10{sup 6} n/s on the detector active area, showing a detection efficiency of about 10{sup −4}, while the detection efficiency of X-rays is more than three orders of magnitude higher. The detector has been also tested under DT neutron flux (14 MeV) up to 2.8×10{sup 8} n/s on the whole detector, with a detection efficiency of about 10{sup −5}. The calibration of the γ-rays detection has been done by means of a source of {sup 60}Co (gamma rays of energy 1.17 MeV and 1.33 MeV) and the detection efficiency was found of the order of 10{sup −4}. Thanks to the adjustable gain of the detector and the discrimination threshold of the electronics, it is possible to minimize the sensitivity to neutrons and gamma, and discriminate the X-ray signals even with very high radiative background.

  18. Study of recombination processes for 'electron-hole' pairs in germanium irradiated by {gamma} rays from {sup 60}Co using the photovoltaic effect in P-N junctions; Etude du processus de recombinaison des paires ''electron-trou'' dans le germanium irradie par les rayons {gamma} du cobalt 60 a l'aide de l'effet photovoltaique dans les jonctions P-N

    Energy Technology Data Exchange (ETDEWEB)

    Zahedi-Mochadam, A A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-10-01

    Using the photo-voltaic effect in p-n junctions, we have studied, during bombardment, the mechanism of the recombination of 'electron-hole' pairs in the presence of structure defects produced in germanium of the N and P types by {gamma} rays from a Co{sup 60} source. At 310 K the level of the recombination centres is situated 0.25 eV above the conduction band and the capture cross-sections of the holes and of the electrons have the respective values of: {sigma}{sub p} = 4 X 10{sup -15} cm{sup 2} and {sigma}{sub n} = 3 X 10{sup -15} cm{sup 2}. The value of {sigma}{sub n} appears to be under-estimated because the number of defects in P-type samples appears to be lower than that in N-type samples. These results lead to the conclusion that the interstitials are responsible for the recombination. At 80 K it has been found that in N-type samples, a shallow level exists at O.05 eV below the conduction band with a capture cross-section for the holes of {sigma}{sub p} {>=} 10{sup -14} cm{sup 2}. We believe that in this case the recombination of charge carriers is controlled by the neighbouring 'defect-interstitial' pairs. In P-type samples at low temperature, the life-time is practically constant during irradiation. This fact is attributed to a spontaneous annealing of defects ol purely electrical origin. In the last part of the work the study of the photo-voltaic effect applied to the problem of gamma radiation dosimetry is considered. It is shown that such dosimeters, based on this principle, make it possible to measure the intensity of gamma rays over a very wide range. (author) [French] En utilisant l'effet photovoltaique dans les jonctions p-n, nous avons etudie au cours du bombardement le mecanisme de recombinaison des paires 'electron-trou' en presence des defauts de structure introduits dans le germanium de type N et de type P par les rayons gamma d'une source de Co{sup 60}. A 310 K, le niveau des centres de recombinaison se trouve a 0,25 eV au-dessous de la bande

  19. Sample analysis using gamma ray induced fluorescent X-ray emission

    Energy Technology Data Exchange (ETDEWEB)

    Sood, B S; Allawadhi, K L; Gandhi, R; Batra, O P; Singh, N [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1983-01-01

    A non-destructive method for the analysis of materials using gamma ray-induced fluorescent x-ray emission has been developed. In this method, special preparation of very thin samples in which the absorption of the incident gamma rays and the emitted fluorescent x-rays is negligible, is not needed, and the absorption correction is determined experimentally. A suitable choice of the incident gamma ray energies is made to minimise enhancement effects through selective photoionization of the elements in the sample. The method is applied to the analysis of a typical sample of the soldering material using 279 keV and 59.5 keV gamma rays from /sup 203/Hg and /sup 241/Am radioactive sources respectively. The results of the analysis are found to agree well with those obtained from the chemical analysis.

  20. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    International Nuclear Information System (INIS)

    May, J.C.; Rey, L.; Lee, C.-J.; Arciniega, Juan

    2004-01-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine

  1. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    Energy Technology Data Exchange (ETDEWEB)

    May, J.C. E-mail: may@cber.fda.gov; Rey, L. E-mail: louis.rey@bluewin.ch; Lee, C.-J.; Arciniega, Juan

    2004-10-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine.

  2. Color centers of a borosilicate glass induced by 10 MeV proton, 1.85 MeV electron and 60Coray

    Science.gov (United States)

    Du, Jishi; Wu, Jiehua; Zhao, Lili; Song, Lixin

    2013-05-01

    Optical absorption spectra, electron paramagnetic resonance (EPR) spectra, Raman spectra of a borosilicate glass after irradiation by 10 MeV proton, 1.85 MeV electron and 60Coray were studied. The process of irradiation inducing color centers in the glass was discussed. The band gap of the glass before and after 60Coray irradiation was studied using Mott and Davis's theory, and it was found that calculated change of the band gap introduced a paradox, because Mott and Davis's theory on the band gap cannot be adopted in the study on the irradiated glass.

  3. ICIT contribution to JET gamma-ray diagnostics enhancement

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Zoita, V.

    2010-01-01

    Full text: Gamma-ray emission of tokamak plasmas is the result of the interaction of fast ions (fusion reaction products, including alpha particles, NBI ions, ICRH-accelerated ions) with main plasma impurities (e.g., carbon, beryllium). Gamma-ray diagnostics involve both gamma-ray imaging (cameras) and gamma-ray spectrometry (spectrometers). For the JET tokamak, gamma-ray diagnostics have been used to provide information on the characteristics of the fast ion population in plasmas. Two gamma-ray diagnostics enhancements project have been launched by JET and the MEdC/EURATOM Association has agreed to lead both of them with ICIT as projects leader. (authors)

  4. Gamma-ray burst observations: the present situation

    International Nuclear Information System (INIS)

    Vedrenne, G.

    1984-01-01

    Recent results in gamma ray burst investigations concerning the spectral variability on a short time scale, precise locations, and the discovery of optical flashes in gamma ray burst positions on archival plates are presented. The implications of optical and X-ray observations of gamma ray burst error boxes are also discussed. 72 references

  5. Found: A Galaxy's Missing Gamma Rays

    Science.gov (United States)

    Kohler, Susanna

    2016-04-01

    Recent reanalysis of data from the Fermi Gamma-ray Space Telescope has resulted in the first detection of high-energy gamma rays emitted from a nearby galaxy. This discovery reveals more about how supernovae interact with their environments.Colliding Supernova RemnantAfter a stellar explosion, the supernovas ejecta expand, eventually encountering the ambient interstellar medium. According to models, this generates a strong shock, and a fraction of the kinetic energy of the ejecta is transferred into cosmic rays high-energy radiation composed primarily of protons and atomic nuclei. Much is still unknown about this process, however. One open question is: what fraction of the supernovas explosion power goes into accelerating these cosmic rays?In theory, one way to answer this is by looking for gamma rays. In a starburst galaxy, the collision of the supernova-accelerated cosmic rays with the dense interstellar medium is predicted to produce high-energy gamma rays. That radiation should then escape the galaxy and be visible to us.Pass 8 to the RescueObservational tests of this model, however, have beenstumped by Arp 220. This nearby ultraluminous infrared galaxy is the product of a galaxy merger ~700 million years ago that fueled a frenzy of starbirth. Due to its dusty interior and extreme levels of star formation, Arp 220 has long been predicted to emit the gamma rays produced by supernova-accelerated cosmic rays. But though weve looked, gamma-ray emission has never been detected from this galaxy until now.In a recent study, a team of scientists led by Fang-Kun Peng (Nanjing University) reprocessed 7.5 years of Fermi observations using the new Pass 8 analysis software. The resulting increase in resolution revealed the first detection of GeV emission from Arp 220!Acceleration EfficiencyGamma-ray luminosity vs. total infrared luminosity for LAT-detected star-forming galaxies and Seyferts. Arp 220s luminosities are consistent with the scaling relation. [Peng et al. 2016

  6. Target size analysis of bioactive substances by radiation inactivation. Comparison with electron beam and. gamma. -ray

    Energy Technology Data Exchange (ETDEWEB)

    Kume, Tamikazu; Watanabe, Yuhei; Ishigaki, Isao; Hirose, Shigehisa

    1988-11-01

    The molecular sizes of various bioactive substances can be measured by the radiation inactivation method. The high energy electron beam (10 MeV) and /sup 60/Co-..gamma.. ray are mainly used for radiation inactivation method. When the practical electron accelerator (/similar to/ 3 MeV) is used for the method, the problems such as penetration and increase of temperature will arise. In this paper the radiation inactivation using 3MeV electron beam is investigated by comparison with ..gamma..-ray. When the plate type glass ampules (glass thickness 1 +- 0.1 mm) were used as the irradiation vessels, relatively uniform dose distribution was obtained. The temperature increased only from 21 degC to 35 degC by irradiation (0.77 mA, 100 passes, 100 kGy). Under the irradiation condition mentioned above, the molecular size of three enzymes were calculated from D/sub 37/ doses. The molecular sizes obtained by electron beam and ..gamma..-ray were 14,000 and 17,000 respectively for lysozyme, 33,000 for pepsin, and 191,000 and 164,000 for yeast alcohol dehydrogenase. These values agreed closely with the reported molecular weight, suggesting that the 3 MeV electron beam can also be used for the radiation inactivation under limited conditions.

  7. Activity evaluation from different native or irradiated with 60 Co gamma rays snake venoms and their inhibitory effect on Leishmania (Leishmania) amazonensis

    International Nuclear Information System (INIS)

    Lourenco, Cecilia de Oliveira

    2000-01-01

    Cutaneous leishmaniasis is a disease, caused by Leishmania parasites, that occurs frequently in tropical and sub-tropical regions of the world. Skin lesions that could results in disfiguring aspect characterize it. The treatment is based on few drugs as antimony salts or pentamidine that are toxic with increasing resistance by the parasite. Alternative forms of disease treatment are in constant search, including natural components as snake venoms. Previous studies demonstrate that some components of snake venoms have an inhibitory effect against those parasites, including Leishmania species. Although snake venoms presented high toxicity, several methods have been described to detoxify most or some of their toxic components, with favorable results by the use of gamma irradiation. In this report we tested several native and irradiated snake venoms for inhibitory effect against Leishmania (Leishmania) amazonensis parasite and LLCMK 2 mammalian cells, with enzymatic tests and electrophoresis. There are significant activity in Acanthophis antarcticus, Agkistrodon bilineatus, Bothrops moojeni, Bothrops jararaca, Hoplocephalus stephensi, Naja melanoleuca, Naja mossambica, Pseudechis australis, Pseudechis colletti, Pseudechis guttatus and Pseudechis porphyriacus, venom being inactive Pseudonaja textilis, Notechis ater niger, Notechis scutatus. Oxyuranus microlepidotus and Oxyuranus scutellatus venoms. After 2 KGy of 60 Co irradiation most venom loses significantly their activity. Venoms with antileishmanial activity presented L-amino acid oxidase (L-AO) activity and showed common protein with a molecular weight about 60kDa in SDS-PAGE. These results indicate that L-AO activity in those venoms are probably related with antileishmanial effect. (author)

  8. Multiwavelength Study of Gamma-Ray Bright Blazars

    Science.gov (United States)

    Morozova, Daria; Larionov, V. M.; Hagen-Thorn, V. A.; Jorstad, S. G.; Marscher, A. P.; Troitskii, I. S.

    2011-01-01

    We investigate total intensity radio images of 6 gamma-ray bright blazars (BL Lac, 3C 279, 3C 273, W Com, PKS 1510-089, and 3C 66A) and their optical and gamma-ray light curves to study connections between gamma-ray and optical brightness variations and changes in the parsec-scale radio structure. We use high-resolution maps obtained by the BU group at 43 GHz with the VLBA, optical light curves constructed by the St.Petersburg State U. (Russia) team using measurements with the 0.4 m telescope of St.Petersburg State U. (LX200) and the 0.7 m telescope of the Crimean Astrophysical Observatory (AZT-8), and gamma-ray light curves, which we have constructed with data provided by the Fermi Large Area Telescope. Over the period from August 2008 to November 2009, superluminal motion is found in all 6 objects with apparent speed ranging from 2c to 40c. The blazars with faster apparent speeds, 3C 273, 3C 279, PKS 1510-089, and 3C 66A, exhibit stronger variability of the gamma-ray emission. There is a tendency for sources with sharply peaked gamma-ray flares to have faster jet speed than sources with gamma-ray light curves with no sharp peaks. Gamma-ray light curves with sharply peaked gamma-ray flares possess a stronger gamma-ray/optical correlations. The research at St.Petersburg State U. was funded by the Minister of Education and Science of the Russian Federation (state contract N#P123). The research at BU was funded in part by NASA Fermi Guest Investigator grant NNX08AV65G and by NSF grant AST-0907893. The VLBA is an instrument of the National Radio Astronomy Observatory, a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc.

  9. Effects of Co60 gamma radiation on Biomphalaria glabrata (Say, 1818) Embryo. II. Malformations

    International Nuclear Information System (INIS)

    Okazaki, K.; Kawano, T.

    1990-01-01

    The morphogenetic effects of ionizing radiation were investigated in Biomphalaria glabrata embryos irradiated in the cleavage, blastula, gastrula, young trochophore and trochophore stages with 5 to 25 Gy doses of 60 CO gamma radiation. The number of malformed embryos rapidly increased with increasing radiation dose, reaching a maximum between 5th to 8th day after irradiation in all stages analyzed. Susceptibility to malformation induction was higher the younger than the age of the irradiated embryo. However, for the cleavage stage the frequency of malformed embryos was inversely proportional to radiation dose for the same radiation dose. Several types of morphogenetic malformations were obtained, among then cephalic malformations, exogastrula, shell malformations and embryos with everted stomodeum, unspecific malformations being the most frequent. The results show that the types of malformation induced by radiation probably are not radiation-specific and do not depend on the dose applied [pt

  10. Effect of. gamma. -radiation of /sup 60/Co on bacteria Sphaerotilus natans in nutrient medium containing calcium and lithium

    Energy Technology Data Exchange (ETDEWEB)

    Leonowicz-Babiak, K; Radziwolska, E; Widera, M

    1980-01-01

    The effect of ..gamma..-radiation of /sup 60/Co on an increase in dry matter of the polysaprobic zone bacteria Sphaerotilus natans was studied. Bacterial growth depended on the radiation dose absorbed. With a rise of the dose, the bacterial dry matter usually decreased. This relationship was not observed at a radiation dose of 72 krad. In the presence of calcium in the medium, the bacterial dry matter increased. An addition of lithium salt to the medium failed to increase the bacterial dry matter.

  11. Experimental investigation of the multiple scatter peak of gamma rays in portland cement in the energy range 279-1332 keV

    International Nuclear Information System (INIS)

    Singh, Tejbir; Singh, Parjit S

    2011-01-01

    The pulse height spectra for different thicknesses of portland cement in the reflected geometry has been recorded with the help of a NaI(Tl) scintillator detector and 2 K MCA card using different gamma-ray sources such as Hg 203 (279 keV), Cs 137 (662 keV) and Co 60 (1173 and 1332 keV). It has been observed that the multiple scatter peak for portland cement appears at 110 (±7) keV in all the spectra irrespective of different incident photon energies in the range 279-1332 keV from different gamma-ray sources. Further, the variation in the intensity of the multiple scatter peak with the thickness of portland cement in the backward semi-cylinders has been investigated.

  12. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  13. DISCOVERY OF GAMMA-RAY PULSATIONS FROM THE TRANSITIONAL REDBACK PSR J1227-4853

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, T. J. [College of Science, George Mason University, Fairfax, VA 22030 (United States); Ray, P. S.; Cheung, C. C. [Space Science Division, Naval Research Laboratory, Washington, DC 20375-5352 (United States); Roy, J.; Bhattacharyya, B.; Stappers, B. W. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Harding, A. K. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Pletsch, H. J.; Fort, S. [Albert-Einstein-Institut, Max-Planck-Institut für Gravitationsphysik, D-30167 Hannover (Germany); Camilo, F. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Deneva, J. [National Research Council Research Associate, National Academy of Sciences, Washington, DC 20001 (United States); Kerr, M., E-mail: tyrel.j.johnson@gmail.com, E-mail: Paul.Ray@nrl.navy.mil, E-mail: jayanta.roy@manchester.ac.uk [CSIRO Astronomy and Space Science, Australia Telescope National Facility, Epping NSW 1710 (Australia)

    2015-06-10

    The 1.69 ms spin period of PSR J1227−4853 was recently discovered in radio observations of the low-mass X-ray binary XSS J12270−4859 following the announcement of a possible transition to a rotation-powered millisecond pulsar state, inferred from decreases in optical, X-ray, and gamma-ray flux from the source. We report the detection of significant (5σ) gamma-ray pulsations after the transition, at the known spin period, using ∼1 year of data from the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. The gamma-ray light curve of PSR J1227−4853 can be fit by one broad peak, which occurs at nearly the same phase as the main peak in the 1.4 GHz radio profile. The partial alignment of light-curve peaks in different wavebands suggests that at least some of the radio emission may originate at high altitude in the pulsar magnetosphere, in extended regions co-located with the gamma-ray emission site. We folded the LAT data at the orbital period, both pre- and post-transition, but find no evidence for significant modulation of the gamma-ray flux. Analysis of the gamma-ray flux over the mission suggests an approximate transition time of 2012 November 30. Continued study of the pulsed emission and monitoring of PSR J1227−4853, and other known redback systems, for subsequent flux changes will increase our knowledge of the pulsar emission mechanism and transitioning systems.

  14. Estimation of the shielding ability of a tungsten functional paper for diagnostic x-rays and gamma rays.

    Science.gov (United States)

    Monzen, Hajime; Kanno, Ikuo; Fujimoto, Takahiro; Hiraoka, Masahiro

    2017-09-01

    Tungsten functional paper (TFP) is a novel paper-based radiation-shielding material. We measured the shielding ability of TFP against x-rays and gamma rays. The TFP was supplied in 0.3-mm-thick sheets that contained 80% tungsten powder and 20% cellulose (C 6 H 10 O 5 ) by mass. In dose measurements for x-rays (60, 80, 100, and 120 kVp), we measured doses after through 1, 2, 3, 5, 10, and 12 TFP sheets, as well as 0.3 and 0.5 mm of lead. In lead equivalence measurements, we measured doses after through 2 and 10 TFP sheets for x-rays (100 and 150 kVp), and 0, 7, 10, 20, and 30 TFP sheets for gamma rays from cesium-137 source (662 keV). And then, the lead equivalent thicknesses of TFP were determined by comparison with doses after through standard lead plates (purity >99.9%). Additionally, we evaluated uniformity of the transmitted dose by TFP with a computed radiography image plate for 50 kVp x-rays. A single TFP sheet was found to have a shielding ability of 65%, 53%, 48%, and 46% for x-rays (60, 80, 100, and 120 kVp), respectively. The lead equivalent thicknesses of two TFP sheets were 0.10 ± 0.02, 0.09 ± 0.02 mmPb, and of ten TFP sheets were 0.48 ± 0.02 and 0.51 ± 0.02 mmPb for 100 and 150 kVp x-rays, respectively. The lead equivalent thicknesses of 7, 10, 20, and 30 sheets of TFP for gamma rays from cesium-137 source were estimated as 0.28, 0.43, 0.91, and 1.50 mmPb with an error of ± 0.01 mm. One TFP sheet had nonuniformity, however, seven TFP sheets provided complete shielding for 50 kVp x-rays. TFP has adequate radiation shielding ability for x-rays and gamma rays within the energy range used in diagnostic imaging field. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  15. Gamma-Ray Emission from Galaxy Clusters : DARK MATTER AND COSMIC-RAYS

    Science.gov (United States)

    Pinzke, Anders

    The quest for the first detection of a galaxy cluster in the high energy gamma-ray regime is ongoing, and even though clusters are observed in several other wave-bands, there is still no firm detection in gamma-rays. To complement the observational efforts we estimate the gamma-ray contributions from both annihilating dark matter and cosmic-ray (CR) proton as well as CR electron induced emission. Using high-resolution simulations of galaxy clusters, we find a universal concave shaped CR proton spectrum independent of the simulated galaxy cluster. Specifically, the gamma-ray spectra from decaying neutral pions, which are produced by CR protons, dominate the cluster emission. Furthermore, based on our derived flux and luminosity functions, we identify the galaxy clusters with the brightest galaxy clusters in gamma-rays. While this emission is challenging to detect using the Fermi satellite, major observations with Cherenkov telescopes in the near future may put important constraints on the CR physics in clusters. To extend these predictions, we use a dark matter model that fits the recent electron and positron data from Fermi, PAMELA, and H.E.S.S. with remarkable precision, and make predictions about the expected gamma-ray flux from nearby clusters. In order to remain consistent with the EGRET upper limit on the gamma-ray emission from Virgo, we constrain the minimum mass of substructures for cold dark matter halos. In addition, we find comparable levels of gamma-ray emission from CR interactions and dark matter annihilations without Sommerfeld enhancement.

  16. Neutron detection gamma ray sensitivity criteria

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  17. Alteration of UV primary fluorescence of vital tumor cells following irradiation with neutrons and gamma rays

    International Nuclear Information System (INIS)

    Merkle, K.

    1980-01-01

    The change of UV primary fluorescence intensity of vital unstained cells of Ehrlich ascites carcinoma after 60 Co-gamma and neutron irradiation was investigated. The mean neutron energy was 6.2 MeV. Fluorescence intensity was detected using impulse cytophotometry. The UV intensity of single cells was measured in the spectral range from 300-400 nm. An monotonous increase of dose-effect curves and a maximum at 3.5 Gy (neutrons) and 30 Gy (γ-rays) was obtained. The first relevant increase of fluorescence intensity was detected at 0.4 Gy (neutrons) and 0.75 Gy (γ-rays). Factors influencing the increase and decrease of primary fluorescence behavior of vital cells are discussed. (author)

  18. The stem and leaf super green mutant induced by 60Co γ-rays irradiation

    International Nuclear Information System (INIS)

    Wei Yubo; Liang Naiting; Buhaliqiem; Zhang Yinbao

    2003-01-01

    Super green gene mutant was developed from population of M 2 generation after the dry seeds of rice Huazhiwu from Japan with good quality and resistance to cold had been irradiated with 50 Gy 60 Co γ-ray. The leaf, sheath, panicle axis and petiole of mutant was characterized by deeply green, and did not turn yellow after maturing date. The chlorophyll content in straw is 2.2 times higher than that in common straw. The results of raising livestock showed that horse, donkey and sheep had evident selectivity to the green straw

  19. Gamma non-ionizing energy loss: Comparison with the damage factor in silicon devices

    Science.gov (United States)

    El Allam, E.; Inguimbert, C.; Meulenberg, A.; Jorio, A.; Zorkani, I.

    2018-03-01

    The concept of non-ionizing energy loss (NIEL) has been demonstrated to be a successful approach to describe the displacement damage effects in silicon materials and devices. However, some discrepancies exist in the literature between experimental damage factors and theoretical NIELs. 60Co gamma rays having a low NIEL are an interesting particle source that can be used to validate the NIEL scaling approach. This paper presents different 60Co gamma ray NIEL values for silicon targets. They are compared with the radiation-induced increase in the thermal generation rate of carriers per unit fluence. The differences between the different models, including one using molecular dynamics, are discussed.

  20. Local gamma ray events as tests of the antimatter theory of gamma ray bursts

    International Nuclear Information System (INIS)

    Sofia, S.; Wilson, R.E.

    1976-01-01

    Nearby examples of the antimatter 'chunks' postulated by Sofia and Van Horn to explain the cosmic gamma ray bursts may produce detectable gamma ray events when struck by solar system meteoroids. These events would have a much shorter time scale and higher energy spectrum than the bursts already observed. In order to have a reasonably high event rate, the local meteoroid population must extend to a distance from the Sun of the order of 0.1 pc, but the required distance could become much lower if the instrumental threshold is improved. The expected gamma ray flux for interaction of the antimatter bodies with the solar wind is also examined, and found to be far below present instrumental capabilities. (Auth.)

  1. Gamma Ray Bursts

    Science.gov (United States)

    Gehrels, Neil; Meszaros, Peter

    2012-01-01

    Gamma-ray bursts (GRBs) are bright flashes of gamma-rays coming from the cosmos. They occur roughly once per day ,last typically lOs of seconds and are the most luminous events in the universe. More than three decades after their discovery, and after pioneering advances from space and ground experiments, they still remain mysterious. The launch of the Swift and Fermi satellites in 2004 and 2008 brought in a trove of qualitatively new data. In this review we survey the interplay between these recent observations and the theoretical models of the prompt GRB emission and the subsequent afterglows.

  2. 60Co Transfer Factor From Lutosol Soil To Leafy Vegetable (Ipomea reptans poir)

    International Nuclear Information System (INIS)

    Leli-Nirwani; Jumaher; Wahyudi

    2003-01-01

    It has been conducted 60 Co transfer study from Lutosol soil to leafy vegetable plant by using pot treatment system. The aim of the research is to obtain data of the transfer factor of 60 Co from lutosol soil to leafy vegetable plant. Pot experiment was carried out by using the complete random design to evaluate two treatment, namely soil with 60 Co and without 60 Co (as a control). 60 Co concentration was with 6.1371 kBq/pot. Tested plant and control plant amount to 12 pots. Each pot contains 1 kg of soil. After harvesting, the weight of dry plant was determined and was conducted with Spectrometer Gamma to 60 Co concentration in dry plant and dry soil. Transfer factor was found to between 0.02 and 0.68 and the average is 0.2068. (author)

  3. Reliability of planar silicon transistors exposed to 60Co γ rays

    International Nuclear Information System (INIS)

    Blin, A.; Le Ber, J.

    1966-01-01

    This report gives an account of results obtained during investigations on the reliability of silicon Planar Transistors, irradiated by the 60 Co γ rays. We consider in a first part the variation of the average values of the parameters of the lots under test. Then, a more complete statistical study is carried out (distribution of the values of the parameters within the lots; research of correlations, etc. ). It is clearly stated and shown that evaluation of the degradation of the gain of transistors depends on: the conditions of measurement (voltage, current), after irradiation; the polarisation of the elements during irradiation; the origin of manufacture of the lots under test (4 manufacturers). We show then the difficulties met to predict the behaviour of the transistors under radiation stress, and attempt is made to define practical rules for design engineers. (author) [fr

  4. Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and 60Co γ-rays

    International Nuclear Information System (INIS)

    Alderman, J.; Job, P. K.; Puhl, J.

    2000-01-01

    The Advanced Photon Source (APS), as well as other third-generation synchrotron light sources, uses permanent magnets in the insertion devices to produce x-rays for scientific research. When placed in a high-energy storage ring, these permanent magnets are subjected to irradiation from synchrotron radiation, high-energy bremsstrahlung, and bremsstrahlung-produced photoneutrons. Previous investigations have exhibited varying degrees of degradation in the intensity of magnetization of these magnets due to irradiation from electron beams, 60 Co γrays, and high-energy neutrons. The APS specifically uses Nd-Fe-B permanent magnets in their insertion devices. Although no detectable radiation-induced demagnetization has been observed in the APS insertion devices so far, partial demagnetization has been observed in at least one insertion device at the European Synchrotron Radiation Facility (ESRF), where Nd-Fe-B permanent magnets are also used

  5. Discoveries by the Fermi Gamma Ray Space Telescope

    Science.gov (United States)

    Gehrels, Neil

    2011-01-01

    Fermi is a large space gamma-ray mission developed by NASA and the DOE with major contributions from France, Germany, Italy, Japan and Sweden. It was launched in June 2008 and has been performing flawlessly since then. The main instrument is the Large Area Telescope (LAT) operating in the 20 MeV to 300 GeV range and a smaller monitor instrument is the Gamma-ray Burst Monitor (GBM) operating in the 8 keV to 40 MeV range. New findings are occurring every week. Some of the key discoveries are: 1) Discovery of many new gamma-ray pulsars, including gamma-ray only and millisecond pulsars. 2) Detection of high energy gamma-ray emission from globular clusters, most likely due to summed emission from msec pulsars. 3) Discovery of delayed and extended high energy gamma-ray emission from short and long gamma-ray busts. 4) Detection of approximately 250 gamma-ray bursts per year with the GBM instrument. 5) Most accurate measurement of the cosmic ray electron spectrum between 30 GeV and 1 TeV, showing some excess above the conventional diffusion model. The talk will present the new discoveries and their implications.

  6. Feasibility study of gamma-ray medical radiography

    International Nuclear Information System (INIS)

    Alyassin, Abdalmajeid M.; Maqsoud, Hamza A.; Mashat, Ahmad M.; Al-Mohr, Al-Sayed; Abdulwajid, Subhan

    2013-01-01

    This research explores the feasibility of using gamma-ray radiography in medical imaging. We will show that gamma-ray medical radiography has the potential to provide alternative diagnostic medical information to X-ray radiography. Approximately one Ci Am-241 radioactive source which emits mono-energetic 59.5 keV gamma rays was used. Several factors that influence the feasibility of this study were tested. They were the radiation source uniformity, image uniformity, and image quality parameters such as contrast, noise, and spatial resolution. In addition, several gamma-ray and X-ray images were acquired using humanoid phantoms. These images were recorded on computed radiography image receptors and displayed on a standard monitor. Visual assessments of these images were then conducted. The Am-241 radioactive source provided relatively uniform radiation exposure and images. Image noise and image contrast were mainly dependent on the exposure time and source size, whereas spatial resolution was dependent on source size and magnification factor. The gamma-ray humanoid phantom images were of lower quality than the X-ray images mainly due to the low radioactivity used and not enough exposure time. Nevertheless, the gamma-ray images displayed most of the main structures contained in the humanoid phantoms. Higher exposure rates and thus lower exposure times were estimated for different pure Am-241 source sizes that are hypothesized to provide high quality images similar to X-ray images. For instance, a 10 mm source size of pure Am-241 with 7 s exposure time should produce images similar in contrast and noise to X-ray images. This research paves the way for the production and usage of a highly radioactive Am-241 source with the potential to lead to the feasibility of acceptable quality medical gamma-ray radiography. - Highlights: ► Characterized the performance of gamma-ray radiography. ► Displayed medical images of humanoid phantoms using gamma radiography. ► Am-241

  7. Introscopy using gamma sources

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Leonov, B.I.; Najorov, A.N.; Smirnov, N.N.; Firstov, V.G.

    1978-01-01

    A method is described of working with standard 170 Tm, 75 Se, 192 Ir, 137 Cs and 60 Co sources at the activity of 1-4000 Ci, during television gamma introscopy of steel products. Experiments involving the RI-10T introscope are carried out to determine prospects of using various radiation sources. The results of using X-ray instruments for control of steel products are also shown for comparison. In introscopy of X-rayed steel products over 25 mm thick, spreading of the edge of the detected groove image is shown to be comparable when using X radiation and gamma radiation of standard sources. Sensitivity of control by fluorographic introscope in X-raying and gamma irradiation of products over 25 mm thick will presumably be the same owing to the detector storage capacity. The use of commercial gamma flaw detecting instruments together with a television introscope permits to reliably reveal defects of 0.5-2.0 mm in size, eliminating possible instability of operation of X-ray instruments, particularly in field conditions

  8. Gamma-ray transients and related astrophysical phenomena

    International Nuclear Information System (INIS)

    Lingenfelter, R.E.; Hudson, H.S.; Worrall, D.M.

    1982-01-01

    The workshop covered the study of the explosive phenomena responsible for the various gamma ray transients. X-ray burster observations and theories were also reviewed with emphasis on their relationship to gamma ray bursts. Recent observational data, particularly from the SMM, HEAO, and VENERA satellites made the workshop especially timely. Major headings include: gamma-ray transients, x-ray bursts, solar transients, and instrumental concepts. Individual items from the workshop were prepared separately for the data base

  9. Cosmic gamma-ray background radiation. Current understandings and problems

    International Nuclear Information System (INIS)

    Inoue, Yoshiyuki

    2015-01-01

    The cosmic gamma-ray background radiation is one of the most fundamental observables in the gamma-ray band. Although the origin of the cosmic gamma-ray background radiation has been a mystery for a long time, the Fermi gamma-ray space telescope has recently measured it at 0.1-820 GeV and revealed that the cosmic GeV gamma-ray background is composed of blazars, radio galaxies, and star-forming galaxies. However, Fermi still leaves the following questions. Those are dark matter contribution, origins of the cosmic MeV gamma-ray background, and the connection to the IceCube TeV-PeV neutrino events. In this proceeding, I will review the current understandings of the cosmic gamma-ray background and discuss future prospects of cosmic gamma-ray background radiation studies. (author)

  10. Gamma-Ray Interactions for Reachback Analysts

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-02

    This presentation is a part of the DHS LSS spectroscopy training course and presents an overview of the following concepts: identification and measurement of gamma rays; use of gamma counts and energies in research. Understanding the basic physics of how gamma rays interact with matter can clarify how certain features in a spectrum were produced.

  11. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds; Efeitos de baixas doses de radiacao gama do Co-60 (radio-hormesis) em sementes de tomate

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni Andreas

    2010-07-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5{sup th} leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  12. DOSKMF2, Dose Rate Distribution in Co60 Gamma Irradiation Plants

    International Nuclear Information System (INIS)

    Remer, M.

    1988-01-01

    1 - Description of program or function: The DOSKMF2 code calculates dose rate distributions in gamma irradiation facilities with 60 Co sources. It has been developed as a tool for the evaluation of research units for the characterization, modification and optimization as well as for the simulation, planning design and evaluation of pilot and industrial facilities. 2 - Method of solution: The basic model of DOSKMF2 contains the computation of the exposure rate, which is dependent on a system of radiation sources (line and/or point sources) at one point of the radiation field. The geometric conditions are described by two coordinate systems. The first is used to arrange the radiation sources and tubes; the second is used to describe the shielding layers in the form of concentric circles. The build-up factor is approximated by Taylor coefficients, also in the case of multi-layer configurations. Calculations of radiation fields in complex irradiation facilities are made by many organizational variants based on the basic model. The interpretation of the results is supported by some statistical calculations. It is possible to store the calculated dose rate values for further processing. 3 - Restrictions on the complexity of the problem: The DOSKMF2 code is presently limited to 40 irradiation tubes and 10 crossed shielding layers. This can be increased by changing dimension statements and input organization

  13. Gamma-ray spectrometry applied to down-hole logging

    International Nuclear Information System (INIS)

    Dumesnil, P.; Umiastowsky, K.

    1983-11-01

    Gamma-ray spectrometry permits to improve the accuracy of natural gamma, gamma-gamma and neutron-gamma geophysical measurements. The probe developed at Centre d'Etudes Nucleaires de Saclay allows down-hole gamma-ray spectrometry. Among others, this probe can be applied to the uranium content determination by selective natural gamma method, down-hole determination of the ash content in the coal by gamma-gamma selective method and elemental analysis by neutron-gamma method. For the calibration and an exact interpretation of the measurements it is important to know the gamma-ray and neutron characteristics of the different kinds of rocks considered as probabilistic variables

  14. Gamma ray transitions in de-excitation of 252Cf spontaneous fission fragments

    International Nuclear Information System (INIS)

    Khan, N.A.; Rashid, K.; Ahmad, M.; Qureshi, I.E.; Alam, G.D.; Ali, A.; Bhatti, N.; Horsch, F.

    1983-11-01

    Gamma rays in the range from 60 keV to 730 keV have been observed following the spontaneous fission of 252 Cf, with high resolution Ge(Li) detector, full width at half maximum (FWHM) of 700 eV at 122 keV, in coincidence with the two fission fragments observed with surface barrier detectors. A total number of 18, 636, 549 events were recorded over a run period of about 150 hours stretching over three weeks. The events were sorted to generate gamma ray spectra belonging to 2 amu intervals gamma of the fragment masses and 6 MeV intervals of the total kinetic energy released. Some of the prominent gamma lines belonging to various masses of the fission fragments have been identified. For some gamma lines, the intensities have been evaluated as a function of the total kinetic energy of the fission fragments. (authors)

  15. Gamma-Ray Imaging Spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; Maccallum, C.J.; Stang, P.D.; Sandia Labs., Albuquerque, NM)

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments

  16. High-energy gamma-ray emission in compact binaries

    International Nuclear Information System (INIS)

    Cerutti, Benoit

    2010-01-01

    Four gamma-ray sources have been associated with binary systems in our Galaxy: the micro-quasar Cygnus X-3 and the gamma-ray binaries LS I +61 degrees 303, LS 5039 and PSR B1259-63. These systems are composed of a massive companion star and a compact object of unknown nature, except in PSR B1259-63 where there is a young pulsar. I propose a comprehensive theoretical model for the high-energy gamma-ray emission and variability in gamma-ray emitting binaries. In this model, the high-energy radiation is produced by inverse Compton scattering of stellar photons on ultra-relativistic electron-positron pairs injected by a young pulsar in gamma-ray binaries and in a relativistic jet in micro-quasars. Considering anisotropic inverse Compton scattering, pair production and pair cascade emission, the TeV gamma-ray emission is well explained in LS 5039. Nevertheless, this model cannot account for the gamma-ray emission in LS I +61 degrees 303 and PSR B1259-63. Other processes should dominate in these complex systems. In Cygnus X-3, the gamma-ray radiation is convincingly reproduced by Doppler-boosted Compton emission of pairs in a relativistic jet. Gamma-ray binaries and micro-quasars provide a novel environment for the study of pulsar winds and relativistic jets at very small spatial scales. (author)

  17. Gamma radiation effects of {sup 60} Co on Bombyx mori (Lep., Bombycidae) modifying the silk fiber production; Influencia da radiacao gama ({sup 60} Co) na producao de fios de seda em Bombyx mori(Lep.,Bombycidae)

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Junior, Francisco [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil); Bendassolli, Jose A. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    1997-12-01

    The present work aimed to verify the biological effects of the application of different doses of gamma radiation during the fifth instar of the silkworm catepillar. Sevently eight silkworm caterpillars (Bombyx mori) were irradiated with {gamma}{sup 60} Co radiation at the initial period of the fifth instar. The caterpillars were divided and classified in six batches of thirteen individuals each. Treatments 1 through 5 received 20, 40, 60, 80 and 100 Gy, respectively, and the control, also consisted of thirteen caterpillars, was not irradiated. The results showed a general increase in the silk fiber content in the irradiated batches compared to the control. The weight of the silk cocoons was higher with increasing doses of irradiation, from 20 to 80 Gy, respectively, followed by a decrease in weight in the treatment irradiated with 100 Gy. the results obtained in this experiment enable the conclusion that the radiation applied to the caterpillars significantly influenced the production of silk fiber in this species. (author). 4 refs., 2 figs., 3 tabs.

  18. VHE Gamma-ray Supernova Remnants

    Energy Technology Data Exchange (ETDEWEB)

    Funk, Stefan; /KIPAC, Menlo Park

    2007-01-22

    Increasing observational evidence gathered especially in X-rays and {gamma}-rays during the course of the last few years support the notion that Supernova remnants (SNRs) are Galactic particle accelerators up to energies close to the ''knee'' in the energy spectrum of Cosmic rays. This review summarizes the current status of {gamma}-ray observations of SNRs. Shell-type as well as plerionic type SNRs are addressed and prospect for observations of these two source classes with the upcoming GLAST satellite in the energy regime above 100 MeV are given.

  19. n-BA/KOH/t-BHP behaviour in the natural rubber latex vulcanization by gamma rays

    International Nuclear Information System (INIS)

    Souza, A. de.

    1994-01-01

    Natural rubber latex was vulcanized in the absence and in the presence of sensitizer (S), with gamma ray from 60 Co source, panoramic type, at the dose rate range of 1,20-1,33 kGy/h. The components of used S were n-butyl acrylate (n-BA), the KOH as stabilizer and t-butyl hydroperoxide (t-BHP) as co-S. The purpose of this work was to study the efficiency and the behaviour of each component of S in the irradiated latex crosslinking by tensile strength (T b ), volume fraction and permanent set. In the absence of S occur straight crosslinking between macromolecular adjacent radicals. IN the presence of S, the n-BA participates in the crosslinking through acrylic bridges between macromolecules. (author)

  20. Gamma-ray spectrum of the radiaoctive dust produced by the super-hydrogen bomb test explosion on March 1, 1954

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, S.

    1987-03-15

    The super-hydrogen bomb test explosion, the so-called Bravo test of a fission-fusion-fission bomb, was carried out on Bikini Atoll in the mid-Pacific on March 1, 1954. Twenty-three Japanese fishermen on board a fishing boat about 90 miles north-east of the test site were attacked unexpectedly by the fallout, radioactive fine debris of coral reef. Within several months after the accident by radiochemical analysis about 20 different nuclides of fission products and, in addition, a considerable amount of /sup 235/U were discovered from the fallout. As we have been preserving a minute amount of the original fallout dust collected on board the fishing boat 31 years ago, measurements of ..gamma.. rays from it have recently been used to find some active nuclides, if still existing. In the ..gamma..-ray spectrum observed there exist evident peaks of ..gamma.. and X-rays from /sup 241/Am, /sup 155/Eu, /sup 137/Cs and /sup 60/Co. Absolute intensities of these four nuclides, still remaining 31 years after the explosion of the bomb, have been estimated. Some discussion on our finding is presented.

  1. Gamma-rays from decaying dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Bertone, G. [Paris-6 Univ., 75 (France). Inst. d' Astrophysique; Buchmueller, W.; Covi, L.; Ibarra, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2007-10-15

    We study the prospects for detecting gamma-rays from decaying Dark Matter (DM), focusing in particular on gravitino DM in R-parity breaking vacua. Given the substantially different angular distribution of the predicted gamma-ray signal with respect to the case of annihilating DM, and the relatively poor (of order 0.1 ) angular resolution of gamma-ray detectors, the best strategy for detection is in this case to look for an exotic contribution to the gamma-ray flux at high galactic latitudes, where the decaying DM contribution would resemble an astrophysical extragalactic component, similar to the one inferred by EGRET observations. Upcoming experiments such as GLAST and AMS-02 may identify this exotic contribution and discriminate it from astrophysical sources, or place significant constraints on the mass and lifetime of DM particles. (orig.)

  2. Study of X-rays and nuclear gamma -rays in muonic thallium

    CERN Document Server

    Backe, H; Jahnke, U; Kankeleit, E; Pearce, R M; Petitjean, C; Schellenberg, L; Schneuwly, H; Schröder, W U; Walter, H K; Zehnder, A

    1972-01-01

    Energies and intensities of muonic X-rays, nuclear gamma -rays and mu -capture gamma -rays were measured in natural muonic thallium with Ge (Li) detectors. The absolute intensities of higher mu X-rays were reproduced by a cascade calculation starting with a statistical population at n=20 including K-, L- and M-conversion. The electron screening effect was deduced from energies of higher mu X-rays. Eight prompt nuclear gamma -rays were found. This excitation explains the anomalous intensity ratios of the 2p-1s and 3d-2p fine structure components. From the nuclear gamma -rays of the first excited states were deduced: the magnetic h.f. splittings, muonic isomer shifts E2/M1 mixing ratios and the half-life in the presence of the muon in /sup 205/Tl. Evidence for a magnetic nuclear polarization was found. An isotope shift of Delta E=10.35+or-0.25 keV was measured for the 1s/sub 1/2/ state which is compared with data from optical spectroscopy. From an analysis of the time distribution of delayed gamma -rays from mu...

  3. gamma. -ray. Present status and problems

    Energy Technology Data Exchange (ETDEWEB)

    Okudaira, K [Rikkyo Univ., Tokyo (Japan). Faculty of Science

    1975-01-01

    As ..gamma..-ray advances straightly through space, the study on cosmic ..gamma..-ray will give the information concerning the origin directly. However, the intensity is weak, and the avoidance of background is a serious problem. The wide-spread components were studied by OSO-3. The intensity of the galactic disc component around 100 MeV was reported as (3.4+-1.0)x10/sup -5/ photons (cm/sup 2/, radian, sec)/sup -1/ by OSO-3 and 0.2x10/sup -4/ photons (cm/sup 2/, radian sec)/sup -1/ by SAS-2, and corresponds to the calculated ..gamma.. yield from ..pi../sup 0/. The strong disc component, so-called galactic center region, has been observed, and is due to the mixture of ..gamma..-ray from ..pi../sup 0/ and inverse Compton ..gamma..-ray. A peak at 476+-24 KeV was found as well as the continuous component. Special care must be taken for the observation of isotropic component, since it is hardly distinguished from the background. It is considered that the isotropic component is due to the inverse Compton scattering of 3/sup 0/K radiation in super-galactic space and the contribution from outer galaxy. The nearest point source of ..gamma..-ray is the sun. Among the other point sources, the crab nebula is the most reliable one. The energy flux of pulse component showed the spectrum of E/sup -1/. ..gamma..-ray bursts were observed by man-made satellites Vela-5 and 6. Theoretical explanation is still incomplete regarding the bursts. (Kato, T.).

  4. Biochemical and pharmacological studies of native and irradiated crotamine with gamma radiation of {sup 60}Co; Estudo bioquimico e farmacologico das crotaminas nativa e irradiada com radiacao gama de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Mitake, Malvina Boni

    2000-07-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide from the South American rattlesnake venom, composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of this thesis was carry out biochemical and pharmacological studies of native and irradiated crotamine with {sup 60} Co. Crotamine was purified from Crotalus durissus terrificus venom by Sephadex G-100 gel filtration followed by ion exchange chromatography, using a Fast Performance Liquid Chromatography (FPLC) system. It was irradiated at 2 mg/ml in 0.15 M Na Cl with 2.0 kGy gamma radiation emitted by a {sup 60} Co source. The native and irradiated crotamine were evaluated by biochemical characterization, toxic activity (LD{sub 50} and biodistribution. The native and irradiated crotamine were labelled with 29.6 MBq of {sup 125} I using chloramine T method, and separated in a Sephadex G-50 column. Male Swiss mice (35{+-} 5 g), were injected i.p. with o.1 mL (2.4 x 10{sup 6} cpm/mouse) of {sup 125} I native crotamine or with 0.4 mL (1.3 x 10{sup 6} cpm/mouse) of {sup 125} I irradiated crotamine. At 0.08; 0.25; 0.5; 1; 2; 4; 8; 12 and 24 hours the animal were killed by ether inhalation. Blood, spleen, liver, kidneys, brain, lungs, heart, and skeletal muscle were collected in order to determine radioactivity content. The results showed that gamma radiation did not change the protein concentration, the electroforetic profile or the primary structure of the protein, although differences were shown by spectroscopic techniques. The gamma radiation diminished the toxicity of crotamine, but it did not abolish bioactivity. Biodistribution studies showed that native and irradiated crotamine have hepatic metabolism and renal elimination. The native and irradiated crotamine have affinity by skeletal

  5. SYSTEMATIC STUDY OF GAMMA-RAY-BRIGHT BLAZARS WITH OPTICAL POLARIZATION AND GAMMA-RAY VARIABILITY

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Ryosuke; Fukazawa, Yasushi; Kanda, Yuka; Shiki, Kensei; Kawabata, Miho; Nakaoka, Tatsuya; Takaki, Katsutoshi; Takata, Koji; Ui, Takahiro [Department of Physical Science, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Nalewajko, Krzysztof; Madejski, Greg M. [Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Accelerator Laboratory, Stanford University, 2575 Sand Hill Road M/S 29, Menlo Park, CA 94025 (United States); Uemura, Makoto; Tanaka, Yasuyuki T.; Kawabata, Koji S.; Akitaya, Hiroshi; Ohsugi, Takashi [Hiroshima Astrophysical Science Center, Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Schinzel, Frank K. [Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM 87131 (United States); Moritani, Yuki [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo Institutes for Advanced Study, The University of Tokyo, Kashiwa, Chiba 277-8583 (Japan); Sasada, Mahito [Institute for Astrophysical Research, Boston University, 725 Commonwealth Avenue, Boston, MA 02215 (United States); Yamanaka, Masayuki, E-mail: itoh@hep01.hepl.hiroshima-u.ac.jp, E-mail: itoh@hp.phys.titech.ac.jp [Department of Physics, Faculty of Science and Engineering, Konan University, Okamoto, Kobe, Hyogo 658-8501 (Japan); and others

    2016-12-10

    Blazars are highly variable active galactic nuclei that emit radiation at all wavelengths from radio to gamma rays. Polarized radiation from blazars is one key piece of evidence for synchrotron radiation at low energies, and it also varies dramatically. The polarization of blazars is of interest for understanding the origin, confinement, and propagation of jets. However, even though numerous measurements have been performed, the mechanisms behind jet creation, composition, and variability are still debated. We performed simultaneous gamma-ray and optical photopolarimetry observations of 45 blazars between 2008 July and 2014 December to investigate the mechanisms of variability and search for a basic relation between the several subclasses of blazars. We identify a correlation between the maximum degree of optical linear polarization and the gamma-ray luminosity or the ratio of gamma-ray to optical fluxes. Since the maximum polarization degree depends on the condition of the magnetic field (chaotic or ordered), this result implies a systematic difference in the intrinsic alignment of magnetic fields in parsec-scale relativistic jets between different types of blazars (flat-spectrum radio quasars vs. BL Lacs) and consequently between different types of radio galaxies (FR I versus FR II).

  6. Gamma-ray spectroscopy on irradiated fuel rods

    International Nuclear Information System (INIS)

    Terremoto, Luis Antonio Albiac

    2009-01-01

    The recording of gamma-ray spectra along an irradiated fuel rod allows the fission products to be qualitatively and quantitatively examined. Among all nondestructive examinations performed on irradiated fuel rods by gamma-ray spectroscopy, the most comprehensive one is the average burnup measurement, which is quantitative. Moreover, burnup measurements by means of gamma-ray spectroscopy are less time-consuming and waste-generating than burnup measurements by radiochemical, destructive methods. This work presents the theoretical foundations and experimental techniques necessary to measure, using nondestructive gamma-ray spectroscopy, the average burnup of irradiated fuel rods in a laboratory equipped with hot cells. (author)

  7. GAMMA RAYS FROM STAR FORMATION IN CLUSTERS OF GALAXIES

    International Nuclear Information System (INIS)

    Storm, Emma M.; Jeltema, Tesla E.; Profumo, Stefano

    2012-01-01

    Star formation in galaxies is observed to be associated with gamma-ray emission, presumably from non-thermal processes connected to the acceleration of cosmic-ray nuclei and electrons. The detection of gamma rays from starburst galaxies by the Fermi Large Area Telescope (LAT) has allowed the determination of a functional relationship between star formation rate and gamma-ray luminosity. Since star formation is known to scale with total infrared (8-1000 μm) and radio (1.4 GHz) luminosity, the observed infrared and radio emission from a star-forming galaxy can be used to quantitatively infer the galaxy's gamma-ray luminosity. Similarly, star-forming galaxies within galaxy clusters allow us to derive lower limits on the gamma-ray emission from clusters, which have not yet been conclusively detected in gamma rays. In this study, we apply the functional relationships between gamma-ray luminosity and radio and IR luminosities of galaxies derived by the Fermi Collaboration to a sample of the best candidate galaxy clusters for detection in gamma rays in order to place lower limits on the gamma-ray emission associated with star formation in galaxy clusters. We find that several clusters have predicted gamma-ray emission from star formation that are within an order of magnitude of the upper limits derived in Ackermann et al. based on non-detection by Fermi-LAT. Given the current gamma-ray limits, star formation likely plays a significant role in the gamma-ray emission in some clusters, especially those with cool cores. We predict that both Fermi-LAT over the course of its lifetime and the future Cerenkov Telescope Array will be able to detect gamma-ray emission from star-forming galaxies in clusters.

  8. Determination of structural geometric parameters of industrial ceramic foams by gamma rays transmission and X-rays microtomography

    International Nuclear Information System (INIS)

    Rocha, Wilson Roberto Dejato da

    2005-01-01

    In this work, the gamma rays transmission and X-rays microtomography techniques are used for the evaluation of the porosity and the pore size distribution of SiC ceramic foams. It was also accomplished the three-dimensional images after the determination of samples geometric parameters. The geometric parameters were obtained by two-dimensional images analyses, generated by a Microfocus system, with a CCD camera, an images intensifier, a X-rays tube and an automatic system for rotation of the sample. The spatial resolution of the images was about 32 μm. In the gamma rays transmission methodology, a Nal(Tl) scintillation detector, an 241 Am (59.53 keV, 100 mCi) radioactive source and an automatic X-Z micrometric table was used. The analyzed samples had pores density of 30, 45, 60, 80 and 100 ppi (pores per inch). The gamma rays transmission technique was accurate to supply the porosity of the samples, which ranged about 90% and was in agreement with the values supplied by manufacturer of the foams. The 30 and 45 ppi samples analyzed by X-rays microtomography showed porosity results that agree with the average porosity supplied by the manufacturer. In other hand, the 60, 80 and 100 ppi samples systematically showed average porosity about 4%, lower than the average of the manufacturer. The pore size distributions found through the software IMAGO show the presence of smaller pores than those nominated by the manufacturer. The 30 ppi samples had voids inside the solid material of the ceramic foams structure. Gaussian truncated method, used in the three-dimensional reconstruction, was not able to take into the account the voids inside the solid matrix. (author)

  9. Elimination of N-nitrosamines and their precusors in some foods by 60Co γ-ray irradiation

    International Nuclear Information System (INIS)

    Hu Jifan; He Yingqiang; Song Puju

    1987-01-01

    N-Dimethylnitrosamine (NDMA) in some marine foods, such as dried shrimp, fish meal and salted fish, was drastically reduced by γ-ray irradiation with 60 Co. The shrimp contained 54.6 ppb NDMA, but only 29.3, 8.8, 11.4, and 1.9 ppb were detected after irradiation with doses of 5, 10, 15 and 20 kGy. The corresponding reduction was 46.3%, 83.9%, 79.1%, and 96.6%, respectively. Similar results were also obtained in other two kinds of foods. NDMA could be completely eliminated by the irradiation in aqueous solution, which was much more markable than that in food samples. The major irradiated products of NDMA were dimethylamine and nitrous acid, but no re-formation of nitrosamines took place. 60 Co irradiation also significantly decreased the content of nitrite in salted fish and in aqueous solution. No effect on nitrate could be observed

  10. Radiation sensitivity of noise in monolithic JFET circuits exposed to 60Co γ - rays

    International Nuclear Information System (INIS)

    Cesura, G.; Re, V.; Tomasini, A.

    1993-01-01

    The spectral density of channel current noise in JFET's is governed in the low-frequency region by Lorentzian terms. Ordinarily, their influence on the equivalent noise charge of preamplifiers for radiation detectors is negligible, as these terms vanish as soon as the frequency exceeds a few Hz. Exposure of JFET's to γ - rays has proved, however, that these noise contributions are enhanced by the absorbed radiation and may invade a much broader frequency range, thereby degrading the equivalent noise charge even at comparatively short processing times. The extent to which the noise behaviour of JFET's is affected by radiation-enhanced Lorentzian terms is analysed in this paper. Results of measurements, carried out after exposure to 60 Co γ - rays of JFET parts and monolithic circuits realised in two different technologies, are discussed and compared with the theoretical predictions. (orig.)

  11. Studies on apple preservation by 60 -gamma irradiation

    International Nuclear Information System (INIS)

    Wang Chuanyao; Jiang Mengyue; Gao Meixu

    1992-01-01

    Studies on '60'Co-gamma irradiation of Golden Delicious apple have been carried out. The results showed that the optimum irradiation dosage for stored apple was ranged from 0.3-0.5 k Gy, with this dosage, the contents of vitamin c and titratalbe acidity in these apples had no significant change compared with unirradiated apples. The respiratory rate and the amount of ethylene release were decreased after irradiation. The mortality of the verticillate pathogenic fungi was 97% at the dose of 0.5 k Gy

  12. A low-background gamma-ray assay laboratory for activation analysis

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Langland, J.K.; Lindstrom, D.J.; Slaback, L.A.

    1990-01-01

    The sources of background in a gamma-ray detector were experimentally determined in underground and surface counting rooms, and an optimized shield was constructed at NIST. The optimum thickness of lead was 10-15 cm, with a greater thickness giving an increased background due to the buildup of tertiary cosmic-ray particles. Neither cadmium, tin, copper nor plastic (hydrocarbon or fluorocarbon) was desirable as a shield liner, since all these increased the background continuum or introduced characteristic peaks into the background spectrum. Two broad peaks in the background result from inelastic scattering of cosmic-ray neutrons (0.02 cm -2 s -1 ) in germanium. These neutrons also excite the lower nuclear levels of lead and structural iron to produce additional gamma-ray peaks in the spectrum. The influence of the 20 MW NIST reactor, located 60 m from the detector, was undetectable. Comparisons among detectors and locations clearly separate cosmic from environmental components of the background. (orig.)

  13. A low-background gamma-ray assay laboratory for activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, R M; Langland, J K [National Inst. of Standards and Technology, Gaithersburg, MD (USA). Center for Analytical Chemistry; Lindstrom, D J [National Aeronautics and Space Administration, Houston, TX (USA). Lyndon B. Johnson Space Center; Slaback, L A [National Inst. of Standards and Technology, Gaithersburg, MD (USA). Occupational Health and Safety Div.

    1990-12-20

    The sources of background in a gamma-ray detector were experimentally determined in underground and surface counting rooms, and an optimized shield was constructed at NIST. The optimum thickness of lead was 10-15 cm, with a greater thickness giving an increased background due to the buildup of tertiary cosmic-ray particles. Neither cadmium, tin, copper nor plastic (hydrocarbon or fluorocarbon) was desirable as a shield liner, since all these increased the background continuum or introduced characteristic peaks into the background spectrum. Two broad peaks in the background result from inelastic scattering of cosmic-ray neutrons (0.02 cm{sup -2} s{sup -1}) in germanium. These neutrons also excite the lower nuclear levels of lead and structural iron to produce additional gamma-ray peaks in the spectrum. The influence of the 20 MW NIST reactor, located 60 m from the detector, was undetectable. Comparisons among detectors and locations clearly separate cosmic from environmental components of the background. (orig.).

  14. Gamma radiation effects of 60 Co on Bombyx mori (Lep., Bombycidae) modifying the silk fiber production

    International Nuclear Information System (INIS)

    Carneiro Junior, Francisco; Bendassolli, Jose A.

    1997-01-01

    The present work aimed to verify the biological effects of the application of different doses of gamma radiation during the fifth instar of the silkworm catepillar. Sevently eight silkworm caterpillars (Bombyx mori) were irradiated with γ 60 Co radiation at the initial period of the fifth instar. The caterpillars were divided and classified in six batches of thirteen individuals each. Treatments 1 through 5 received 20, 40, 60, 80 and 100 Gy, respectively, and the control, also consisted of thirteen caterpillars, was not irradiated. The results showed a general increase in the silk fiber content in the irradiated batches compared to the control. The weight of the silk cocoons was higher with increasing doses of irradiation, from 20 to 80 Gy, respectively, followed by a decrease in weight in the treatment irradiated with 100 Gy. the results obtained in this experiment enable the conclusion that the radiation applied to the caterpillars significantly influenced the production of silk fiber in this species. (author). 4 refs., 2 figs., 3 tabs

  15. Effect of 60Co γ-ray irradiation on cytoskeleton of human peripheral blood monocytes with whole mount cell electron microscopy in vitro

    International Nuclear Information System (INIS)

    Chen Xiaomei; Guo Yuhua; Yin Zhiwei

    1992-01-01

    Whole mount cell electron microscopy was used in combination with selective extraction to prepare cytoskeletal framework. Cytoskeleton prepared by Triton X-100 treatment of human peripheral blood monocytes appeared on electron microscopy as a highly organized and interconnected three-dimensional matrix of different fibrous elements. By three-dimensional visualization of Triton X-100 resistant cytoskeletons it was demonstrated that different doses of 60 Co γ-rays caused distinctive and reproducible alterations of the cytoskeleton of intact human peripheral blood monocytes in vitro. The alterations were similar to those caused by cytochalasin B and by colchicine. From these observations and other workers'studies, it is presumed that 60 Co γ-ray irradiation may inhibit cytoplasmic microtubule and microfilament assembling

  16. Gamma-Ray Pulsar Studies With GLAST

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, D.J.; /NASA, Goddard

    2011-11-23

    Some pulsars have their maximum observable energy output in the gamma-ray band, offering the possibility of using these high-energy photons as probes of the particle acceleration and interaction processes in pulsar magnetospheres. After an extended hiatus between satellite missions, the recently-launched AGILE mission and the upcoming Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) will allow gamma-ray tests of the theoretical models developed based on past discoveries. With its greatly improved sensitivity, better angular resolution, and larger energy reach than older instruments, GLAST LAT should detect dozens to hundreds of new gamma-ray pulsars and measure luminosities, light curves, and phase-resolved spectra with unprecedented resolution. It will also have the potential to find radio-quiet pulsars like Geminga, using blind search techniques. Cooperation with radio and X-ray pulsar astronomers is an important aspect of the LAT team's planning for pulsar studies.

  17. Egret observations of the extragalactic gamma-ray emission

    DEFF Research Database (Denmark)

    Sreekumar, P.; Bertsch, D.L.; Dingus, B.L.

    1998-01-01

    The all-sky survey in high-energy gamma rays (E > 30 MeV) carried out by EGRET aboard the Compton Gamma Ray Observatory provides a unique opportunity to examine in detail the diffuse gamma-ray emission. The observed diffuse emission has a Galactic component arising from cosmic-ray interactions wi...

  18. Sensitivity of Gamma-Ray Detectors to Polarization

    OpenAIRE

    Yadigaroglu, I. -A.

    1996-01-01

    Previous studies have shown that the largest gamma-ray detector to date, EGRET, does not have useful polarization sensitivity. We have explored here some improved approaches to analyzing gamma-ray pair production events, leading to important gains in sensitivity to polarization. The performance of the next generation gamma-ray instrument GLAST is investigated using a detailed Monte Carlo simulation of the complete detector.

  19. Bulk density calculations from prompt gamma ray yield

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Maslehuddin, M.

    2006-01-01

    Full text: The gamma ray yield from a Prompt Gamma ray Neutron Activation Analysis (PGNAA) setup is a linear function of element concentration and neutron flux in a the sample with constant bulk density. If the sample bulk density varies as well, then the element concentration and the neutron flux has a nonlinear correlation with the gamma ray yield [1]. The measurement of gamma ray yield non-linearity from samples and a standard can be used to estimate the bulk density of the samples. In this study the prompt gamma ray yield from Blast Furnace Slag, Fly Ash, Silica Fumes and Superpozz cements samples have been measured as a function of their calcium and silicon concentration using KFUPM accelerator-based PGNAA setup [2]. Due to different bulk densities of the blended cement samples, the measured gamma ray yields have nonlinear correlation with calcium and silicon concentration of the samples. The non-linearity in the yield was observed to increase with gamma rays energy and element concentration. The bulk densities of the cement samples were calculated from ratio of gamma ray yield from blended cement and that from a Portland cement standard. The calculated bulk densities have good agreement with the published data. The result of this study will be presented

  20. Airborne gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Hovgaard, Jens

    A new method - Noise Adjusted Singular Value Decomposition, NASVD - for processing gamma-ray spectra has been developed as part of a Ph.D. project. By using this technique one is able to decompose a large set of data - for example from airborne gamma-ray surveys - into a few spectral components....... By knowing the spectral components and their amplitudes in each of the measured spectra one is able to extract more information from the data than possible with the methods used otherwise....

  1. Life shortening, tumor induction, and tissue dose for fission-neutron and gamma-ray irradiations

    International Nuclear Information System (INIS)

    Grahn, D.; Duggal, K.; Lombard, L.S.

    1985-01-01

    The primary focus of this program is to obtain information on the late effects of whole body exposure to low doses of a high linear-energy-transfer (LET) and a low-LET ionizing radiation in experimental animals to provide guidance for the prediction of radiation hazards to man. The information obtained takes the form of dose-response curves for life shortening and for the induction of numerous specific types of tumors. The animals are irradiated with fission neutrons from the Janus reactor and with 60 Co gamma rays, delivered as single, weekly, or duration-of-life exposures covering the range of doses and dose rates. 6 refs

  2. Multiple Gamma-Ray Detection Capability of a CeBr3 Detector for Gamma Spectroscopy

    Directory of Open Access Journals (Sweden)

    A. A. Naqvi

    2017-01-01

    Full Text Available The newly developed cerium tribromide (CeBr3 detector has reduced intrinsic gamma-ray activity with gamma energy restricted to 1400–2200 keV energy range. This narrower region of background gamma rays allows the CeBr3 detector to detect more than one gamma ray to analyze the gamma-ray spectrum. Use of multiple gamma-ray intensities in elemental analysis instead of a single one improves the accuracy of the estimated results. Multigamma-ray detection capability of a cylindrical 75 mm × 75 mm (diameter × height CeBr3 detector has been tested by analyzing the chlorine concentration in water samples using eight chlorine prompt gamma rays over 517 to 8578 keV energies utilizing a D-D portable neutron generator-based PGNAA setup and measuring the corresponding minimum detection limit (MDC of chlorine. The measured MDC of chlorine for gamma rays with 517–8578 keV energies varies from 0.07 ± 0.02 wt% to 0.80 ± 0.24. The best value of MDC was measured to be 0.07 ± 0.02 wt% for 788 keV gamma rays. The experimental results are in good agreement with Monte Carlo calculations. The study has shown excellent detection capabilities of the CeBr3 detector for eight prompt gamma rays over 517–8578 keV energy range without significant background interference.

  3. Detection the human mitochondrial DNA 4977 bp deletion induced by 60Co γ-rays in vitro by nest-PCR

    International Nuclear Information System (INIS)

    Feng Jiangbing; Lu Xue; Chen Deqing; Liu Qingjie; Chen Xiaosui

    2004-01-01

    Objective: To establish a method for detecting the mitochondrial DNA 4977 bp deletion (mtDNA 4977) induced by different doses of ionizing radiation. Methods: A nest-PCR method was established with 3 primer pairs for detecting the human peripheral mtDNA 4977. The final PCR products were sequenced after purified and the sequence was BLASTed with the standard genome information of human mitochondrion. The mtDNA 4977 level induced by 0-5 Gy 60 Co γ-rays of 5 healthy individuals was analyzed with the established nest-PCR. Results: The mtDNA 4977 could be detected by the established nest-PCR method. The mtDNA 4977 was observed on samples after exposed to 1-5 Gy 60 Co γ-rays, but it was not observed before (0 Gy) exposure. Conclusion: The nest-PCR method established in this study could be used to detect the mtDNA 4977 induced by ionizing radiation. (authors)

  4. FERMI LAT DISCOVERY OF EXTENDED GAMMA-RAY EMISSIONS IN THE VICINITY OF THE HB 3 SUPERNOVA REMNANT

    Energy Technology Data Exchange (ETDEWEB)

    Katagiri, H.; Yoshida, K. [College of Science, Ibaraki University, 2-1-1, Bunkyo, Mito 310-8512 (Japan); Ballet, J. [Laboratoire AIM, CEA-IRFU/CNRS/Université Paris Diderot, Service d’Astrophysique, CEA Saclay, F-91191 Gif sur Yvette (France); Grondin, M.-H.; Lemoine-Goumard, M. [Centre d’Études Nucléaires de Bordeaux Gradignan, IN2P3/CNRS, Université Bordeaux 1, BP120, F-33175 Gradignan Cedex (France); Hanabata, Y. [Institute for Cosmic-Ray Research, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba, 277-8582 (Japan); Hewitt, J. W. [Department of Physics and Center for Space Sciences and Technology, University of Maryland Baltimore County, Baltimore, MD 21250 (United States); Kubo, H., E-mail: hideaki.katagiri.sci@vc.ibaraki.ac.jp, E-mail: 13nm169s@gmail.com [Department of Physics, Graduate School of Science, Kyoto University, Kyoto (Japan)

    2016-02-20

    We report the discovery of extended gamma-ray emission measured by the Large Area Telescope (LAT) onboard the Fermi Gamma-ray Space Telescope in the region of the supernova remnant (SNR) HB 3 (G132.7+1.3) and the W3 II complex adjacent to the southeast of the remnant. W3 is spatially associated with bright {sup 12}CO (J = 1–0) emission. The gamma-ray emission is spatially correlated with this gas and the SNR. We discuss the possibility that gamma rays originate in interactions between particles accelerated in the SNR and interstellar gas or radiation fields. The decay of neutral pions produced in nucleon–nucleon interactions between accelerated hadrons and interstellar gas provides a reasonable explanation for the gamma-ray emission. The emission from W3 is consistent with irradiation of the CO clouds by the cosmic rays accelerated in HB 3.

  5. Growing, regeneration and radiosensibility of sugarcane callus (Saccharum spp. hybrid var. “SP 70-1284” treated with gamma radiation source 60Co.

    Directory of Open Access Journals (Sweden)

    Apolonio Valdez Balero

    2004-07-01

    Full Text Available Calluses in growth of sugar cane, variety “SP 70-1284”, were radiated with a source of 60Co. The studied doses were between 10 and 80 Gy. The affectation of the Gamma radiation source 60Co in the growth of the callus and the regeneration of plants was evaluated. The results indicated that the dose that diminished the growth of callus in a value under 50% was the one of 30 Gy, and also the dose that diminished the regenerative capacity of the callus below to the 50% of the population was the one of 30 Gy. The results showed that for this variety of sugar cane doses superior to 30Gy of Gamma radiations jeopardizes the growth and the later regeneration of the callus. Its application is recommended to induce genetic variability in the variety of sugar cane “SP 70-1284”, as well as in programs of genetic improvement by mutations, in susceptible varieties of the sugar cane red blight (Puccinia melanocephala Syd using calluses in growth. Key words: callus, hybrid, in vitro, improvement, rust, Saccharum sp, variability

  6. Yield and Chemical Composition of Cucumber Treated by Nitrogen Levels and Doses of Gamma Rays

    International Nuclear Information System (INIS)

    Fath El-Bab, T.Sh.; Abo El-Khier, Om.M.; Abdallah, A.A.G.

    2013-01-01

    Two field experiments were performed at the Atomic Energy Authority, Experimental farm, Inshas, Egypt during 2010 and 2011 summer growing seasons in sandy soil. The experiments were conducted to study the effect of pre-sowing seeds which treated by gamma irradiation with different doses of 0, 2, 4 and 6 Gy. This was in combination with three rates of nitrogen, fertilizer i.e., 30, 60 and 90 Kg N/fed. The experiments were laid out using drip irrigation system. The obtained results indicated that gamma rays doses showed significant differences on cucumber yield per plot or per Fed., increasing doses of gamma rays gradually increased cucumber yield per plot up to highest dose, i.e., (6 Gy). The highest value of total yield was obtained with the highest nitrogen rate (90 Kg N/fed.). Doses of gamma rays significantly increased total soluble solids (T.S.S.), total Carbohydrates, fats, total protein, NPK and Ca of cucumber fruits. Application of 60 Kg N/fed. recorded the highest values of all above mentioned chemical characters except of total protein with 90 kg N/fed. every all dose treatments. The effect of interaction between doses and fertilizer levels on chemical characters were significant therefore, the highest values was found at 4 Gy and 60 Kg N/fed. treatment for protein, fat, nitrogen and potassium contents while the carbohydrate and calcium contents had the highest value with the treatment of 6 Gy and 60 Kg N/fed

  7. Observational techniques of gamma rays astronomy in low energy

    International Nuclear Information System (INIS)

    Costa, J.M. da.

    1982-02-01

    Due to the absorption of great part of the gamma-ray spectrum of cosmic origin, by the earth's atmosphere at heights above 20Km, gamma-ray astronomy achieved its full development only after the advent of the space age. Ballons and satellites are the space vehicles which have been used to transport gamma-ray telescopes to observational heights in the atmosphere, or out of it. The results of these experiments can determine the sources, the energy spectra and the intensities of the cosmic gamma-rays, and provide other important information of astrophysical interest. The detection of gamma-rays of cosmic origin is very difficult. The observational techniques used in gamma-ray astronomy are dependent on the energy range of the gamma-rays which one desires to detect. The most common telescopes of low energy gamma-ray astronomy (50KeV - 20MeV) use NaI(Tl) scintillators, or germanium diodes, as principal detectors, surrounded by an active shield (anticoincidence) of organic or inorganic scintillators. (Author) [pt

  8. Possible galactic origin of. gamma. -ray bursts

    Energy Technology Data Exchange (ETDEWEB)

    Manchanda, R K; Ramsden, D [Southampton Univ. (UK). Dept. of Physics

    1977-03-31

    It is stated that extragalactic models for the origin of non-solar ..gamma..-ray bursts include supernova bursts in remote galaxies, and the collapse of the cores of active stars, whilst galactic models are based on flare stars, thermonuclear explosions in neutron stars and the sudden accretion of cometary gas on to neutron stars. The acceptability of any of these models may be tested by the observed size spectrum of the ..gamma..-ray bursts. The extragalactic models predict a power law spectrum with number index -1.5, whilst for the galactic models the number index will be -1. Experimental data on ..gamma..-ray bursts is, however, still meagre, and so far only 44 confirmed events have been recorded by satellite-borne instruments. The number spectrum of the observed ..gamma..-ray bursts indicates that the observed distribution for events with an energy < 10/sup -4/ erg/cm/sup 2/ is flat; this makes the choice of any model completely arbitrary. An analysis of the observed ..gamma..-ray events is here presented that suggests very interesting possibilities for their origin. There appears to be a preferred mean energy for ..gamma..-ray bursts; some 90% of the recorded events show a mean energy between 5 x 10/sup -5/ and 5 x 10/sup -4/ erg/cm/sup 2/, contrary to the predicted characteristics of the number spectrum of various models. A remarkable similarity is found between the distribution of ..gamma..-ray bursts and that of supernova remnants, suggesting a genetic relationship between the two and the galactic origin of the ..gamma..-ray bursts, and the burst source could be identified with completely run down neutron stars, formed during supernova explosions.

  9. The Dawn of Nuclear Photonics with Laser-based Gamma-rays

    International Nuclear Information System (INIS)

    Barty, C.J.

    2011-01-01

    A renaissance in nuclear physics is occurring around the world because of a new kind of incredibly bright, gamma-ray light source that can be created with short pulse lasers and energetic electron beams. These highly Mono-Energetic Gamma-ray (MEGa-ray) sources produce narrow, laser-like beams of incoherent, tunable gamma-rays and are enabling access and manipulation of the nucleus of the atom with photons or so called 'Nuclear Photonics'. Just as in the early days of the laser when photon manipulation of the valence electron structure of the atom became possible and enabling to new applications and science, nuclear photonics with laser-based gamma-ray sources promises both to open up wide areas of practical isotope-related, materials applications and to enable new discovery-class nuclear science. In the United States, the development of high brightness and high flux MEGa-ray sources is being actively pursued at the Lawrence Livermore National Laboratory in Livermore (LLNL), California near San Francisco. The LLNL work aims to create by 2013 a machine that will advance the state of the art with respect to source the peak brightness by 6 orders of magnitude. This machine will create beams of 1 to 2.3 MeV photons with color purity matching that of common lasers. In Europe a similar but higher photon energy gamma source has been included as part of the core capability that will be established at the Extreme Light Infrastructure Nuclear Physics (ELI-NP) facility in Magurele, Romania outside of Bucharest. This machine is expected to have an end point gamma energy in the range of 13 MeV. The machine will be co-located with two world-class, 10 Petawatt laser systems thus allowing combined intense-laser and gamma-ray interaction experiments. Such capability will be unique in the world. In this talk, Dr. Chris Barty from LLNL will review the state of the art with respect to MEGa-ray source design, construction and experiments and will describe both the ongoing projects

  10. Terrestrial gamma-ray flashes

    Science.gov (United States)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-08-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models.

  11. Terrestrial gamma-ray flashes

    International Nuclear Information System (INIS)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-01-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models

  12. Research on securing no bacteria and nonfeverish property for disposable medical appliances. Inactivation of endotoxin by Co-60 γ ray

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari; Tanamoto, Kenichi; Haijima, Yuji.

    1996-01-01

    The contamination by fever-causing endotoxin has become a large problem in medical treatment field. In the industry manufacturing disposable medical appliances, the method of manufacturing endotoxin-free products is an important subject, and the development of the methods of inactivating and eliminating efficiently endotoxin is desired. As a part of this development, the possibility of inactivating endotoxin with Co-60 γ ray was examined. The sample was the endotoxin originated from E.Coli R3 F653 strain. For the irradiation, the Co-60 γ ray irradiation apparatus of 185 T-Bq in National Institute of Hygienic Sciences was used. The measurement of the activity of endotoxin was carried out by limulus test synthetic substrate method. The activity value of the endotoxin in aqueous solution decreased logarithmically with the increasing irradiation dose, and this decreasing tendency was not affected by the initial concentration of the endotoxin. The experiment of recovering freezing-dried endotoxin from a vial is described. The results of inactivating the endotoxin in dry system by γ ray are reported. (K.I.)

  13. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  14. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  15. Gamma-Ray Bursts: 4th Huntsville Symposium. Proceedings

    International Nuclear Information System (INIS)

    Meegan, C.A.; Preece, R.D.; Koshut, T.M.

    1998-01-01

    These proceedings represent papers presented at the Fourth Huntsville Gamma-Ray Bursts Symposium held in September, 1997 in Huntsville, Alabama, USA. This conference occurred at a crucial time in the history of the gamma-ray burst research. In early 1997, 30 years after the detection of the first gamma-ray burst by the Vela satellites, counterparts to bursts were finally detected at optical and radio wavelengths. The symposium attracted about 200 scientists from 16 countries. Some of the topics discussed include gamma-ray burst spectra, x-ray observations, optical observations, radio observations, host galaxies, shocks and afterglows and models of gamma-ray bursts. There were 183 papers presented, out of these, 16 have been abstracted for the Energy Science and Technology database

  16. The supernova-gamma-ray burst-jet connection.

    Science.gov (United States)

    Hjorth, Jens

    2013-06-13

    The observed association between supernovae and gamma-ray bursts represents a cornerstone in our understanding of the nature of gamma-ray bursts. The collapsar model provides a theoretical framework for this connection. A key element is the launch of a bipolar jet (seen as a gamma-ray burst). The resulting hot cocoon disrupts the star, whereas the (56)Ni produced gives rise to radioactive heating of the ejecta, seen as a supernova. In this discussion paper, I summarize the observational status of the supernova-gamma-ray burst connection in the context of the 'engine' picture of jet-driven supernovae and highlight SN 2012bz/GRB 120422A--with its luminous supernova but intermediate high-energy luminosity--as a possible transition object between low-luminosity and jet gamma-ray bursts. The jet channel for supernova explosions may provide new insights into supernova explosions in general.

  17. Catalog of gamma-rays unplaced in radioactive decay schemes

    International Nuclear Information System (INIS)

    Narita, Tsutomu; Kitao, Kensuke.

    1991-03-01

    A catalog is made for gamma-rays emitted in decay of radioactive nuclides but not placed in their decay schemes. It consists of two tables. In Table 1, the number of these unplaced gamma-ray components by a nuclide is given together with the fraction of total intensity of these gamma-rays to that of all observed gamma-rays. In Table 2, the unplaced gamma-rays are arranged in order of increasing energy. Each line of this table contains the gamma-ray energy, intensity, nuclide identification, and energies and intensities of the most prominent gamma-rays from the decay of the radionuclides. This catalog is a compilation from Evaluated Nuclear Structure Data File (ENSDF) maintained by National Nuclear Data Center at Brookhaven National Laboratory, of at February 1990. (author)

  18. Safety protection and technical improvement of 60Co irradiation facilities

    International Nuclear Information System (INIS)

    Zhou Yongxing; Liang Cannan

    1993-01-01

    To ensure personal safety, some improvements has been made in the design of 60 Co irradiation compartment. The shielding door was interlocked while the 60 Co source to be lifted to the irradiation position or lowered to the shielded position. A universal change-over switch was used to cut the power supply when the source moved beyond the limits. Both γ-ray alarm and a closed-TV system were adopted. The electromagnetic attraction method was employed to shift the 60 Co source from the Pb container to the source pipe

  19. Differential expression of genome in the progeny doubling 40 generations of normal human liver cells irradiated by 60Co γ rays

    International Nuclear Information System (INIS)

    Zuo Yahui; Wang Fang; Geng Xiaohua; Wang Xiaoli; Li Jianguo; Wang Zhongwen; Tong Jian

    2008-01-01

    In order to investigate the differential expression of genome in nomal human liver cell irradiated by 60 Co γ rays, cDNA chip was applied to assay the alterations of transcriptional profile of nomal human liver cell'rogeny exposed to 4 Gy and 8 Gy of γ ray from 60 Co. Then Quantitative real-time PCR was used to confirm the commonly changed genes including VTN and INSIG1. The results demonstrated that the transcription level of 58 genes changed in the progeny of survival cells irradiated by 4 Gy γ rays, while 882 genes changed in the progeny of survival cells irradiated by 8 Gy γ rays. 16 genes changed in these cells irradiated by both 4 and 8 Gy γ rays. The transcription level was correlated to the original irradiation dose. Most of the genes were associated with transduction, cell cycle regulation, cellular immunity, cytoskeleton and movement, cell replication and repair mechanism, etc. The changed transcriptional level was further confirmed by RT-PCR assay for some of these genes. The results showed that differential expression of genome irradiated by different doses of γ rays. These results offer the fundamental materials for the research of genomic instability induced by radiation on the molecular level. (authors)

  20. Near stellar sources of gamma-ray bursts

    OpenAIRE

    Luchkov, B. I.; Markin, P. D.

    2012-01-01

    Correlation analysis of gamma-ray burst coordinates and nearby stars, registered on 2008-2011, revealed 5 coincidences with angular accuracy better than 0.1 degree. The random probability is $7\\times 10^{-7}$, so evidencing that coincident stars are indeed gamma-ray burst sources. The proposed method should be continued in order to provide their share in common balance of cosmic gamma-ray bursts.