WorldWideScience

Sample records for clupeidae optic chiasm

  1. Optic chiasm in the species of order Clupeiformes, family Clupeidae: optic chiasm of Spratelloides gracilis shows an opposite laterality to that of Etrumeus teres.

    Science.gov (United States)

    Mogi, Kazue; Misawa, Kazuya; Utsunomiya, Kentaro; Kawada, Yuta; Yamazaki, Toshihisa; Takeuchi, Shigeo; Toyoizumi, Ryuji

    2009-09-01

    In most teleost fishes, the optic nerves decussate completely as they project to the mesencephalic region. Examination of the decussation pattern of 25 species from 11 different orders in Pisces revealed that each species shows a specific chiasmic type. In 11 species out of the 25, laterality of the chiasmic pattern was not determined; in half of the individuals examined, the left optic nerve ran dorsally to the right optic nerve, while in the other half, the right optic nerve was dorsal. In eight other species the optic nerves from both eyes branched into several bundles at the chiasmic point, and intercalated to form a complicated decussation pattern. In the present study we report our findings that Spratelloides gracilis, of the order Clupeiformes, family Clupeidae, shows a particular laterality of decussation: the left optic nerve ran dorsally to the right (n=200/202). In contrast, Etrumeus teres, of the same order and family, had a strong preference of the opposite (complementary) chiasmic pattern to that of S. gracilis (n=59/59), revealing that these two species display opposite left-right optic chiasm patterning. As far as we investigated, other species of Clupeiformes have not shown left-right preference in the decussation pattern. We conclude that the opposite laterality of the optic chiasms of these two closely related species, S. gracilis and E. teres, enables investigation of species-specific laterality in fishes of symmetric shapes.

  2. The history of optic chiasm from antiquity to the twentieth century.

    Science.gov (United States)

    Costea, Claudia Florida; Turliuc, Şerban; Buzdugă, Cătălin; Cucu, Andrei Ionuţ; Dumitrescu, Gabriela Florenţa; Sava, Anca; Turliuc, Mihaela Dana

    2017-11-01

    The optic chiasm is an essential structure located at the skull base that stirred over time the curiosity of anatomists, who became more and more interested in its structure and function. Through centuries, the optic chiasm was viewed as a vessel crossing, a way of transporting tears secreted by the brain to the eye, integrating images, or responsible for coordinated eye movements. The paper aims to overview the history of understanding the optic chiasm from the beginnings of antiquity to the twentieth century. We reviewed the literature and studied all the historical sources on optic chiasm and eyes in the works of ancient, medieval, Renaissance authors, and the seventeenth to nineteenth century works. The optic chiasm is a structure that fascinated ancient anatomists and made them develop various theories on its function. In terms of function, the optic chiasm had a history based more on speculation, the seventeenth century bringing its first understanding and reaching the peak in the nineteenth century with the understanding of the anatomical structure of the chiasm and its role in the visual process. The history of the optic chiasm is a fascinating time travel displaying the conceptual transformations that have been made in anatomy and medicine by our forerunners.

  3. Herniated gyrus rectus causing idiopathic compression of the optic chiasm.

    Science.gov (United States)

    Smith, Jacob; Jack, Megan M; Peterson, Jeremy C; Chamoun, Roukoz B

    2017-02-01

    Anomalies in the frontal lobe can interfere with visual function by compression of the optic chiasm and nerve. The gyrus rectus is located at the anterior cranial fossa floor superior to the intracranial optic nerves and chiasm. Compression of these structures by the gyrus rectus is often caused by neoplastic or dysplastic growth in the area. We report a rare case of a herniated gyrus rectus impinged on the optic chiasm and nerve without a clear pathological cause for the herniation. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Abnormal lateral geniculate nucleus and optic chiasm in human albinism.

    Science.gov (United States)

    Mcketton, Larissa; Kelly, Krista R; Schneider, Keith A

    2014-08-01

    Our objective was to measure how the misrouting of retinal ganglion cell (RGC) fibers affects the organization of the optic chiasm and lateral geniculate nuclei (LGN) in human albinism. We compared the chiasmal structures and the LGN in both pigmented controls and patients with albinism by using high-resolution structural magnetic resonance imaging (MRI). We studied 12 patients with oculocutaneous albinism and 12 age-matched pigmented controls. Using a 3T MRI scanner, we acquired a T1 -weighted three-dimensional magnetization-prepared rapid gradient-echo (MPRAGE) image of the whole brain, oriented so that the optic nerves, chiasm, and tracts were in the same plane. We acquired multiple proton density-weighted images centered on the thalamus and midbrain, and averaged them to increase the signal, enabling precise manual tracing of the anatomical boundaries of the LGN. Albinism patients exhibited significantly smaller diameters of the optic nerves, chiasm and tracts, and optic chiasm and LGN volume compared with controls (P albinism compared with the control group can be attributed to the abnormal crossing of optic fibers and the reduction of RGCs in the central retina. The volume of the LGN devoted to the center of the visual field may be reduced in albinism due to fewer RGCs representing the area where the fovea would normally lie. Our data may be clinically useful in addressing how genetic deficits compromise proper structural and functional development in the brain. © 2014 Wiley Periodicals, Inc.

  5. Position and width of normal adult optic chiasm as measured in coronal MRI

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Park, Jin Sook

    1994-01-01

    To evaluate the position and transverse dimension of the adult optic chiasm in normal Korean adult. The authors analysed 3D coronal volume images (TR/TE=30/13, flip angle=30 .deg. ) of 136 normal adult subjects without known visual abnormality. All MRI examinations were performed using a 0.5T system. MRI was reviewed retrospectively to determine the position (horizontal and tilted) of the potic chiosm and the transverse dimension of the optic chiasm was measured. Seventy- five (55%) of the 136 normal subjects had horizontal position, and sixty-one (45%) had tilted position. Thirty- eight (62%) of 61 with tilted position showed higher position on the right side, and twenty-three (38%) showed higher position on the side. The average transverse dimension(mean SD) was 15.2 ± 0.7mm in men and 14.6 ± 1.0mm in women. The difference of transverse dimension between men and women was statistically significant. Tilted position of the adult optic chiasm on coronal MRI was seen in approximately half of normal adults. The average of transverse dimension of normal optic chiasm was 15mm

  6. Technical note: Endoscopic resection of a dermoid cyst anchored to the anterior optic chiasm

    Directory of Open Access Journals (Sweden)

    Yuichiro Yoneoka, MD, PhD

    2014-06-01

    Conclusion: To the best of our knowledge, ours is the only case of a dermoid cyst anchored to the anterior optic chiasma, which was visually confirmed under endoscopic observation. After surgery, the patient presented a transient impairment of the visual field, which was not evident at four month follow-up. It will contribute to a similar case, in which surgeons hesitate to make an incision in the optic chiasm. A subtotal excision should be considered in cases of dermoid cysts anchored to the anterior optic chiasm, because all the previously reported cases of suprasellar dermoid cysts are young people or those who have a relatively long life expectancy.

  7. A route for direct retinal input to the preoptic hypothalamus: dendritic projections into the optic chiasm.

    Science.gov (United States)

    Silver, J; Brand, S

    1979-07-01

    With the use of Golgi, horseradish peroxidase, and electron microscopic techniques, neurons within a broad region of the preoptic hypothalamus of the mouse were shown to have dendrites that projected well into the depths of the optic chiasm. Further experimental and ultrastructural investigation demonstrated synapses between these dendrites and retinal axonal boutons within the chiasm. All synapses located in the chiasm were classified as Gray's type I. The possible function of these dendritic projections is discussed.

  8. Radiotherapy in the management of primary gliomas involving the intracranial optic nerves and chiasm

    International Nuclear Information System (INIS)

    Harter, D.J.; Caderao, J.B.; Leavens, M.E.; Young, S.E.

    1978-01-01

    Surgeons traditionally do not resect optic chiasm gliomas, but megavoltage radiotherapy can be effective treatment. Vision often improves during and after irradiation. Follow-up examination should include an evaluation of endocrine status. In the series reported recurrences became manifest within one year of the treatment

  9. Effects of levothyroxine on visual evoked potential impairment following local injections of lysolecithin into the rat optic chiasm

    Directory of Open Access Journals (Sweden)

    Cobra Payghani

    2018-01-01

    Full Text Available Background: Multiple sclerosis (MS is a demyelinating disease of the central nervous system which has no any known definitive treatment. Studies have shown that thyroid hormones (THs in addition to their roles in the development of the nervous system and the production of myelin have important roles in the adult's brain function. Since the only way to treat MS is the restoration of myelin, the aim of this study was to evaluate the effects of levothyroxine on visual evoked potential (VEP impairment following local injections of lysolecithin into the rat optic chiasm. Methods: To induce demyelination, lysolecithin was injected into the optic chiasm of male Wistar rats. VEP recording was used to evaluate demyelination and remyelination before and 10, 17, and 24 days after the lysolecithin injection. The rats received an intraperitoneal injection of levothyroxine with doses 20, 50, and 100 μg/kg in different experimental groups. Results: VEP latency and amplitude showed demyelination at 10 and 17 days after an induced lesion in MS group which was reversed at day 24. Levothyroxine prevented these impairments, especially in high doses. Conclusions: According to the results, lysolecithin-induced demyelination at optic chiasm and VEP impairments can be restored by administration of levothyroxine. Therefore, THs probably have positive effects in demyelinating diseases.

  10. Postsynaptic potentials recorded in neurons of the cat's lateral geniculate nucleus following electrical stimulation of the optic chiasm.

    Science.gov (United States)

    Bloomfield, S A; Sherman, S M

    1988-12-01

    1. We recorded intracellularly from X and Y cells of the cat's lateral geniculate nucleus and measured the postsynaptic potentials (PSPs) evoked from electrical stimulation of the optic chiasm. We used an in vivo preparation and computer averaged the PSPs to enhance their signal-to-noise ratio. 2. The vast majority (46 of 50) of our sample of X and Y cells responded to stimulation of the optic chiasm with an excitatory postsynaptic potential (EPSP) followed by an inhibitory postsynaptic potential (IPSP); these were tentatively identified as relay cells. We quantified several parameters of these PSPs, including amplitude, latency, time to peak (i.e., rise time), and duration. 3. Among the relay cells, the latencies of both the EPSP and action potential evoked by optic chiasm stimulation were shorter in Y cells than in X cells. Furthermore, the difference between the latencies of the EPSP and action potential was shorter for Y cells than for X cells. This means that the EPSPs generated in Y cells reached threshold for generation of action potentials faster than did those in X cells. The EPSPs of Y cells also displayed larger amplitudes and faster rise times than did those in X cells, but neither of these distinctions was sufficient to explain the shorter latency difference between the EPSP and action potential for Y cells. 4. The EPSPs recorded in relay Y cells had longer durations than did those in relay X cells. Our data suggest that the subsequent IPSP actively terminates the EPSP, which, in turn, suggests that the time interval between EPSP and IPSP onsets is longer in Y cells than in X cells. Furthermore, we found that, for individual Y cells, the latency and duration of the evoked EPSP were inversely related. These observations lead to the conclusion that the latency of IPSPs activated from the optic chiasm is relatively constant among Y cells and thus independent of the EPSP latencies. Thus the excitation and inhibition produced in individual geniculate Y

  11. Congenital aplasia of the optic chiasm and esophageal atresia: a case report

    Directory of Open Access Journals (Sweden)

    Madonia Maurizio

    2011-08-01

    Full Text Available Abstract Introduction The complete absence of the chiasm (chiasmal aplasia is a rare clinical condition. Hypoplasia of the optic nerve and congenital nystagmus are almost invariably associated characteristics. Microphthalmos or anophthalmos are common features in chiasmal aplasia, while central nervous system abnormalities are less frequent. Esophageal atresia can be isolated or syndromic. In syndromic cases, it is frequently associated with cardiac, limb, renal or vertebral malformations and anal atresia. More rarely, esophageal atresia can be part of anophthalmia-esophageal-genital syndrome, which comprises anophthalmia or microphthalmia, genital abnormalities, vertebral defects and cerebral malformations. Here, a previously unreported case of chiasmal aplasia presenting without microphthalmos and associated with esophageal atresia is described. Case presentation Aplasia of the optic chiasm was identified in a Caucasian Italian 8-month-old boy with esophageal atresia. An ultrasound examination carried out at 21 weeks' gestation revealed polyhydramnios. Intrauterine growth retardation, esophageal atresia and a small atrial-septal defect were subsequently detected at 28 weeks' gestation. Repair of the esophageal atresia was carried out shortly after birth. A jejunostomy was carried out at four months to facilitate enteral feeding. The child was subsequently noted to be visually inattentive and to be neurodevelopmentally delayed. Magnetic resonance imaging revealed chiasmal aplasia. No other midline brain defects were found. His karyotype was normal. Conclusion If achiasmia is a spectrum, our patient seems to depict the most severe form, since he appears to have an extremely severe visual impairment. This is in contrast to most of the cases described in the literature, where patients maintain good--or at least useful-- visual function. To the best of our knowledge, the association of optic nerve hypoplasia, complete chiasmal aplasia, esophageal

  12. Extended Endoscopic Endonasal Resection of a Suprasellar and Third Ventricular Retrochiasmatic Craniopharyngioma with a Narrow Pituitary Gland-Optic Chiasm Interval: Techniques to Optimize Resection.

    Science.gov (United States)

    Kenning, Tyler J; Pinheiro-Neto, Carlos D

    2018-04-01

    The extended endoscopic endonasal approach can be utilized to surgically treat pathology within the suprasellar space. This relies on a sufficient corridor and interval between the superior aspect of the pituitary gland and the optic chiasm. Tumors located in the retrochiasmatic space and within the third ventricle, however, may not have a widened interval through which to work. With mass effect on the superior and posterior aspect of the optic chiasm, the corridor between the chiasm and the pituitary gland might even be further narrowed. This may negate the possibility of utilizing the endoscopic endonasal approach for the management of pathology in this location. We present a case of a retrochiasmatic craniopharyngioma with a narrow resection corridor that was treated with the extended endoscopic approach and we review techniques to potentially overcome this limitation. The link to the video can be found at: https://youtu.be/ogRZj-aBqeQ .

  13. Isolated primary central nervous system lymphoma arising from the optic chiasm.

    Science.gov (United States)

    Vassal, F; Pommier, B; Boutet, C; Forest, F; Campolmi, N; Nuti, C

    2014-12-01

    A 58-year-old previously healthy woman rapidly developed progressive bilateral visual loss. Magnetic resonance imaging revealed a bulging appearance of the optic chiasm, with homogeneous enhancement after gadolinium administration, which suggested an optic glioma or inflammatory disease. In the absence of (para)clinical clues for a specific diagnosis despite extensive investigation, a biopsy of one optic nerve was performed, resulting in a diagnosis of non-Hodgkin B-cell lymphoma. There was no evidence of any other ocular or systemic involvement, therefore the conclusion was that this immunocompetent patient had a primary central nervous system lymphoma isolated in the anterior visual pathway. Treatment included two cycles of polychemotherapy (rituximab, methotrexate, carmustine, etoposide, methylprednisolone), followed by autologous peripheral blood stem cell transplantation and rituximab plus cytarabine consolidation therapy. Subsequently, the patient exhibited significant improvement in vision, and was still disease-free at the 1-year follow-up examination. The aim of the present paper was to provide well-documented clinical, radiological, and intraoperative features of isolated primary malignant lymphoma arising from the anterior visual pathway. A better recognition of this rare pathological entity is necessary for clinicians who may encounter similar presentations, as prompt management is crucial for both a visual and vital prognosis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Human induced pluripotent stem cells differentiation into oligodendrocyte progenitors and transplantation in a rat model of optic chiasm demyelination.

    Directory of Open Access Journals (Sweden)

    Alireza Pouya

    Full Text Available BACKGROUND: This study aims to differentiate human induced pluripotent stem cells (hiPSCs into oligodendrocyte precursors and assess their recovery potential in a demyelinated optic chiasm model in rats. METHODOLOGY/PRINCIPAL FINDINGS: We generated a cell population of oligodendrocyte progenitors from hiPSCs by using embryoid body formation in a defined medium supplemented with a combination of factors, positive selection and mechanical enrichment. Real-time polymerase chain reaction and immunofluorescence analyses showed that stage-specific markers, Olig2, Sox10, NG2, PDGFRα, O4, A2B5, GalC, and MBP were expressed following the differentiation procedure, and enrichment of the oligodendrocyte lineage. These results are comparable with the expression of stage-specific markers in human embryonic stem cell-derived oligodendrocyte lineage cells. Transplantation of hiPSC-derived oligodendrocyte progenitors into the lysolecithin-induced demyelinated optic chiasm of the rat model resulted in recovery from symptoms, and integration and differentiation into oligodendrocytes were detected by immunohistofluorescence staining against PLP and MBP, and measurements of the visual evoked potentials. CONCLUSIONS/SIGNIFICANCE: These results showed that oligodendrocyte progenitors generated efficiently from hiPSCs can be used in future biomedical studies once safety issues have been overcome.

  15. Diffuse malignant lymphoma type B with optic chiasm infiltration, visual disturbances, hypopituitarism, hyperprolactinaemia and diabetes insipidus. Case report and literature review

    International Nuclear Information System (INIS)

    Bolanowski, M.; Kuliszkiewicz-Janus, M.; Sokolska, V.

    2006-01-01

    The case is reported of a 55-year-old man with diffuse malignant lymphoma type B associated with transient optic chiasm infiltration and visual disturbances but with persistent hypopituitarism, hyperprolactinaemia and diabetes insipidus. The patient was administered chemotherapy and radiotherapy. Repeated MR and CT scans showed optic chiasm infiltration, which disappeared in the course of the chemotherapy but then recurred, changed its appearance and finally disappeared again. In the meantime visual disturbances occurred and disappeared during the therapy. Hypopituitarism, diabetes insipidus and hyperprolactinaemia were diagnosed and replacement therapy was administered. Later on abdominal pain occurred, and a CT scan revealed bilateral kidney masses and enlarged retroperitoneal lymph nodes. These were diffuse malignant lymphoma with regional lymphonodulitis in histology. Finally, hydrothorax and hydroretroperitoneum were diagnosed. The patient died as a result of systemic complications of the disease. The length of survival time documented following the hypothalamochiasmatic infiltration and diagnosis of lymphoma makes the case an unusual one for patients with CNS lymphoma. Hormonal disturbances accompanying the suprasellar region infiltration are very important from the practical point of view. (author)

  16. Foxg1 regulates retinal axon pathfinding by repressing an ipsilateral program in nasal retina and by causing optic chiasm cells to exert a net axonal growth-promoting activity.

    Science.gov (United States)

    Tian, Natasha M; Pratt, Thomas; Price, David J

    2008-12-01

    Mammalian binocular vision relies on the divergence of retinal ganglion cell axons at the optic chiasm, with strictly controlled numbers projecting contralaterally and ipsilaterally. In mouse, contralateral projections arise from the entire retina, whereas ipsilateral projections arise from ventrotemporal retina. We investigate how development of these patterns of projection is regulated by the contralateral determinant Foxg1, a forkhead box transcription factor expressed in nasal retina and at the chiasm. In nasal retina, loss of Foxg1 causes increased numbers of ipsilateral projections and ectopic expression of the ipsilateral determinants Zic2, Ephb1 and Foxd1, indicating that nasal retina is competent to express an ipsilateral program that is normally suppressed by Foxg1. Using co-cultures that combine Foxg1-expressing with Foxg1-null retinal explants and chiasm cells, we provide functional evidence that Foxg1 promotes contralateral projections through actions in nasal retina, and that in chiasm cells, Foxg1 is required for the generation of a hitherto unrecognized activity supporting RGC axon growth.

  17. A girl without a chiasm : Electrophysiologic and MRI evidence for the absence of crossing optic nerve fibers in a girl with a congenital nystagmus

    NARCIS (Netherlands)

    Jansonius, NM; van der Vliet, TM; Cornelissen, FW; Pott, JWR; Kooijman, AC

    An otherwise healthy 15-year-old girl with a congenital nystagmus was evaluated at our department using visual evoked potential recording and magnetic resonance imaging. She appears to have the unique isolated inborn absence of the optic chiasm, described only once before in two unrelated girls.

  18. Radiation necrosis of the optic chiasm, optic tract, hypothalamus, and upper pons after radiotherapy for pituitary adenoma, detected by gadolinium-enhanced, T1-weighted magnetic resonance imaging: Case report

    International Nuclear Information System (INIS)

    Tachibana, O.; Yamaguchi, N.; Yamashima, T.; Yamashita, J.

    1990-01-01

    A 26-year-old woman was treated for a prolactin secreting pituitary adenoma by surgery and radiotherapy (5860 rads). Fourteen months later, she developed right hemiparesis and dysarthria. A T1-weighted magnetic resonance imaging scan using gadolinium contrast showed a small, enhanced lesion in the upper pons. Seven months later, she had a sudden onset of loss of vision, and radiation optic neuropathy was diagnosed. A T1-weighted magnetic resonance imaging scan showed widespread gadolinium-enhanced lesions in the optic chiasm, optic tract, and hypothalamus. Magnetic resonance imaging is indispensable for the early diagnosis of radiation necrosis, which is not visualized by radiography or computed tomography

  19. Extrinsic and intrinsic blood supply to the optic chiasm.

    Science.gov (United States)

    Salaud, Céline; Ploteau, Stéphane; Blery, Pauline; Pilet, Paul; Armstrong, Olivier; Hamel, Antoine

    2018-04-01

    Although there have been many studies of the arterial cerebral blood supply, only seven have described the optic chiasm (OC) blood supply and their results are contradictory. The aim of this study was to analyze the extrinsic and intrinsic OC blood supply on cadaveric specimens using dissections and microcomputer tomography (Micro-CT). Thirteen human specimens were dissected and the internal or common carotid arteries were injected with red latex, China Ink with gelatin or barium sulfate. Three Micro-CTs were obtained to reveal the intrinsic blood supply to the OC. The superior hypophyseal arteries (SupHypA) (13/13) and posterior communicating artery (PCoA) (12/13) supplied the pial network on the inferior side of the OC. The first segment of the anterior cerebral artery (ACA) (10/10), SupHypA (7/10), the anterior communicating artery (ACoA) (9/10), and PComA (1/10) supplied the pial network of its superior side. The intrinsic OC blood supply was divided into three networks (two lateral and one central). Capillaries entering the OC originated principally from the inferior pial network. The lateral network capillaries had the same orientation as the visual lateral pathways, but the central network was not correlated with the nasal fibers crossing into the OC. There was no anastomosis in the pial or intrinsic networks. Only SupHypA, PCoA, ACoA, and ACA were involved in the OC blood supply. Because there was no extrinsic or intrinsic anastomosis, all arteries should be preserved. Tumor compression of the inferior intrinsic arterial network could contribute to visual defects. Clin. Anat. 31:432-440, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Trans-eyebrow supraorbital approach in large suprasellar craniopharyngioma surgery in adults: analysis of optic nerve length and extent of tumor resection. Original article.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inma; Evangelista, Rocío; Pancucci, Giovanni; Guarín, Juliana; Ayuso, Angel; Misra, Mukesh

    2017-05-01

    One of the main drawbacks in the surgery of large craniopharyngiomas is the presence of a prefixed optic chiasm. Our main objective in this study is to compare the predictive value of the optic nerve length and optic chiasm location on large craniopharyngiomas' extent of resection. We retrospectively studied 21 consecutive patients with large craniopharyngiomas who underwent tumor resection through the trans-eyebrow supraorbital approach. Clinical and radiological findings on preoperative MRI were recorded, including the optic chiasm location classified as prefixed, postfixed or normal. We registered the optic nerve length measured intraoperatively prior to tumor removal and confirmed the measurements on preoperative MRI. Using a linear regression model, we calculated a prediction formula of the percentage of the extent of resection as a function of optic nerve length. On preoperative MRI, 15 patients were considered to have an optic chiasm in a normal location, 3 cases had a prefixed chiasm, and the remaining 3 had a postfixed chiasm. In the group with normal optic chiasm location, a wide range of percentage of extent of resection was observed (75-100%). The percentage of extent of resection of large craniopharyngiomas was observed to be dependent on the optic nerve length in a linear regression model (p < 0.0001). According to this model in the normal optic chiasm location group, we obtained an 87% resection in 9-mm optic nerve length patients, a 90.5% resection in 10-mm optic nerve length patients and 100% resection in 11-mm optic nerve length patients. Optic chiasm location provides useful information to predict the percentage of resection in both prefixed and postfixed chiasm patients but not in the normal optic chiasm location group. Optic nerve length was proven to provide a more accurate way to predict the percentage of resection than the optic chiasm location in the normal optic chiasm location group.

  1. ALDH1A3 loss of function causes bilateral anophthalmia/microphthalmia and hypoplasia of the optic nerve and optic chiasm.

    Science.gov (United States)

    Yahyavi, Mani; Abouzeid, Hana; Gawdat, Ghada; de Preux, Anne-Sophie; Xiao, Tong; Bardakjian, Tanya; Schneider, Adele; Choi, Alex; Jorgenson, Eric; Baier, Herwig; El Sada, Mohamad; Schorderet, Daniel F; Slavotinek, Anne M

    2013-08-15

    The major active retinoid, all-trans retinoic acid, has long been recognized as critical for the development of several organs, including the eye. Mutations in STRA6, the gene encoding the cellular receptor for vitamin A, in patients with Matthew-Wood syndrome and anophthalmia/microphthalmia (A/M), have previously demonstrated the importance of retinol metabolism in human eye disease. We used homozygosity mapping combined with next-generation sequencing to interrogate patients with anophthalmia and microphthalmia for new causative genes. We used whole-exome and whole-genome sequencing to study a family with two affected brothers with bilateral A/M and a simplex case with bilateral anophthalmia and hypoplasia of the optic nerve and optic chiasm. Analysis of novel sequence variants revealed homozygosity for two nonsense mutations in ALDH1A3, c.568A>G, predicting p.Lys190*, in the familial cases, and c.1165A>T, predicting p.Lys389*, in the simplex case. Both mutations predict nonsense-mediated decay and complete loss of function. We performed antisense morpholino (MO) studies in Danio rerio to characterize the developmental effects of loss of Aldh1a3 function. MO-injected larvae showed a significant reduction in eye size, and aberrant axonal projections to the tectum were noted. We conclude that ALDH1A3 loss of function causes anophthalmia and aberrant eye development in humans and in animal model systems.

  2. Correlation between displacement of optic chiasm on MR and visual symptomas and signs

    International Nuclear Information System (INIS)

    Kang, Eun Joo; Jang, Yun Hyung; Baik, Seung Kug; Ahn, Woo Hyun; Choi, Han Yong; Kim, Bong Gi

    1994-01-01

    MR is the most useful imaging method in evaluating the anatomic changes of the optic chiasm (OC). The purpose of this study is to investigate the relationship between the OC displacement and visual manifestations. We retrospectively reviewed 44 patients who showed displacement of OC on brain MR. The pattern of OC displacement was classified into 3 groups according to following criteria: group A included the patients with OC displacement only due to empty sella; group B represented the patients with OC displacement by a lesion and the border between the lesion and OC was distinct; and group C was the patients with OC displacement by a lesion and had a indistinct border or thinning of the OC. Visual symptoms and signs were noted in 12 patients and the most common sign was bitemporal hemianopsia. In group A (7 patients), the visual symptoms and signs were seen in only one patient (14%), in whom contracted visual fields persisted since previous pituitary apoplexy had developed. In group B (30 patients), the visual symptoms and signs were seen in 4 patients (13%) who had tumorous conditions except one case of cysticercosis. In group C (7 patients), the visual symptoms and signs were seen in all patients (100%). The more OC is compressed, the more the prevalence of visual symptoms and signs increases. However, there was no correlation between the occurrence of visual symptoms and the presence of OC displacement only without compression

  3. Binocular vision, the optic chiasm, and their associations with vertebrate motor behavior

    Directory of Open Access Journals (Sweden)

    Matz Lennart Larsson

    2015-07-01

    Full Text Available Ipsilateral retinal projections (IRP in the optic chiasm (OC vary considerably. Most animal groups possess laterally situated eyes and no or few IRP, but, e.g. cats and primates have frontal eyes and high proportions of IRP. The traditional hypothesis that bifocal vision developed to enable predation or to increase perception in restricted light conditions applies mainly to mammals. The eye-forelimb (EF hypothesis presented here suggests that the reception of visual feedback of limb movements in the limb steering cerebral hemisphere was the fundamental mechanism behind the OC evolution. In other words, that evolutionary change in the OC was necessary to preserve hemispheric autonomy. In the majority of vertebrates, motor processing, tactile, proprioceptive, and visual information involved in steering the hand (limb, paw, fin is primarily received only in the contralateral hemisphere, while multisensory information from the ipsilateral limb is minimal. Since the involved motor nuclei, somatosensory areas, and vision neurons are situated in same hemisphere, the neuronal pathways involved will be relatively short, optimizing the size of the brain. That would not have been possible without, evolutionary modifications of IRP. Multiple axon-guidance genes, which determine whether axons will cross the midline or not, have shaped the OC anatomy. Evolutionary change in the OC seems to be key to preserving hemispheric autonomy when the body and eye evolve to fit new ecological niches. The EF hypothesis may explain the low proportion of IRP in birds, reptiles, and most fishes; the relatively high proportions of IRP in limbless vertebrates; high proportions of IRP in arboreal, in contrast to ground-dwelling, marsupials; the lack of IRP in dolphins; abundant IRP in primates and most predatory mammals, and why IRP emanate exclusively from the temporal retina. The EF hypothesis seams applicable to vertebrates in general and hence more parsimonious than

  4. Retinitis Pigmentosa Sine Pigmento Mimicking a Chiasm Disease.

    Science.gov (United States)

    Pellegrini, Francesco; Prosdocimo, Giovanni; Romano, Francesco; Interlandi, Emanuela

    2017-08-01

    A 75-year-old woman presented to her ophthalmologist complaining of visual loss for several years. The ophthalmic examination was remarkable for a bitemporal visual field defect. Magnetic resonance imaging (MRI) scan of the brain was normal without evidence of chiasm compression. Neuro-ophthalmic examination was consistent with a retinal rather than a chiasmal disease. Retinal multimodal imaging helped in the correct diagnosis of retinitis pigmentosa, later confirmed by genetic testing.

  5. Radiation-induced optic neuropathy 4 years after radiation: report of a case followed up with MRI

    International Nuclear Information System (INIS)

    Piquemal, R.; Renard, J.P.; Cottier, J.P.; Herbreteau, D.; Arsene, S.; Rospars, C.; Lioret, E.; Jan, M.

    1998-01-01

    We report a case of radiation-induced optic neuropathy in a 32-year-old man with Cushing's disease and a recurrent tumour of the left cavernous sinus. The patient experienced rapid, painless loss of vision 4 years after treatment without recurrence of tumour or other visual disorder. MRI showed enlargement and contrast enhancement of the optic chiasm. A year later the patient was almost blind and MRI showed atrophy and persistent contrast enhancement of the chiasm. (orig.)

  6. Radiation-induced optic neuropathy 4 years after radiation: report of a case followed up with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Piquemal, R.; Renard, J.P. [Service de Medecine Interne A, Hopital Bretonneau, Tours (France); Cottier, J.P.; Herbreteau, D. [Service de Neuroradiologie, Hopital Bretonneau, Tours (France); Arsene, S.; Rospars, C. [Service d`Ophthalmologie, Hopital Bretonneau, Tpurs (France); Lioret, E.; Jan, M. [Service de Neurochirurgie, Hopital Bretonneau, Tours (France)

    1998-07-01

    We report a case of radiation-induced optic neuropathy in a 32-year-old man with Cushing`s disease and a recurrent tumour of the left cavernous sinus. The patient experienced rapid, painless loss of vision 4 years after treatment without recurrence of tumour or other visual disorder. MRI showed enlargement and contrast enhancement of the optic chiasm. A year later the patient was almost blind and MRI showed atrophy and persistent contrast enhancement of the chiasm. (orig.) With 3 figs., 13 refs.

  7. Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Zikou, Anastasia K.; Tzovara, Ioanna; Margariti, Persefoni [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Nikas, Alexios; Asproudis, Ioannis [University of Ioannina, Ophthalmologic Clinic, Medical School, Ioannina (Greece); Blekas, Kostandinos; Galatsanos, Nikolaos [University of Ioannina, Department of Informatics, Ioannina (Greece)

    2007-07-15

    The purpose of the study was to examine the brain and the visual pathway of patients with non-arteritic anterior ischaemic optic neuropathy (NAION) by using conventional MRI (cMRI) and volumetric magnetisation transfer imaging (MTI). Thirty NAION patients, aged 67.5 {+-} 8.14 years, and 28 age- and gender-matched controls were studied. MTI was used to measure the magnetisation transfer ratio (MTR) of the chiasm and for MTR histograms of the brain. The presence of areas of white matter hyperintensity (WMH) was evaluated on fluid-attenuated inversion recovery (FLAIR) images. Area of the optic nerves (ONs) and volume of the chiasm were assessed, as were coronal short-tau inversion recovery (STIR) and MTI images, respectively. More areas of WMH were observed in patients (total 419; mean 14.4; SD 19) than in controls (total 127; mean 4.7; SD 5.7), P < 0.001. Area (in square millimetres) of the affected ONs, volume(in cubic millimetres) and MTR (in percent) of the chiasm (10.7 {+-} 4.6), (75.8 {+-} 20.2), (56.4 {+-} 6.5), respectively, were lower in patients than in controls (13.6 {+-} 4.3), (158.2 {+-} 75.3) (62.1 {+-} 6.2), respectively, P < 0.05. Mean MTR of brain histograms was lower in patients (53.0 {+-} 8.0) than in controls (58.0 {+-} 5.6), P < 0.05. NAION is characterised by decreased ON and chiasmatic size. The low MTR of the chiasm and brain associated with increased areas of WMH may be suggestive of demyelination and axonal damage due to generalised cerebral vascular disease. (orig.)

  8. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  9. Optic pathway glioma associated with orbital rhabdomyosarcoma and bilateral optic nerve sheath dural ectasia in a child with neurofibromatosis-1

    International Nuclear Information System (INIS)

    Nikas, Ioannis; Theofanopoulou, Maria; Lampropoulou, Penelope; Hadjigeorgi, Christiana; Pourtsidis, Apostolos; Kosmidis, Helen

    2006-01-01

    Neurofibromatosis-1 (NF-1) is a multisystem disorder presenting with a variety of clinical and imaging manifestations. Neural and non-neural tumours, and unusual benign miscellaneous conditions, separately or combined, are encountered in variable locations. We present a 21/2-year-old boy with NF-1 who demonstrated coexisting optic pathway glioma with involvement of the chiasm and optic nerve, orbital alveolar rhabdomyosarcoma and bilateral optic nerve sheath dural ectasia. (orig.)

  10. Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Zikou, Anastasia K.; Tzovara, Ioanna; Margariti, Persefoni; Nikas, Alexios; Asproudis, Ioannis; Blekas, Kostandinos; Galatsanos, Nikolaos

    2007-01-01

    The purpose of the study was to examine the brain and the visual pathway of patients with non-arteritic anterior ischaemic optic neuropathy (NAION) by using conventional MRI (cMRI) and volumetric magnetisation transfer imaging (MTI). Thirty NAION patients, aged 67.5 ± 8.14 years, and 28 age- and gender-matched controls were studied. MTI was used to measure the magnetisation transfer ratio (MTR) of the chiasm and for MTR histograms of the brain. The presence of areas of white matter hyperintensity (WMH) was evaluated on fluid-attenuated inversion recovery (FLAIR) images. Area of the optic nerves (ONs) and volume of the chiasm were assessed, as were coronal short-tau inversion recovery (STIR) and MTI images, respectively. More areas of WMH were observed in patients (total 419; mean 14.4; SD 19) than in controls (total 127; mean 4.7; SD 5.7), P < 0.001. Area (in square millimetres) of the affected ONs, volume(in cubic millimetres) and MTR (in percent) of the chiasm (10.7 ± 4.6), (75.8 ± 20.2), (56.4 ± 6.5), respectively, were lower in patients than in controls (13.6 ± 4.3), (158.2 ± 75.3) (62.1 ± 6.2), respectively, P < 0.05. Mean MTR of brain histograms was lower in patients (53.0 ± 8.0) than in controls (58.0 ± 5.6), P < 0.05. NAION is characterised by decreased ON and chiasmatic size. The low MTR of the chiasm and brain associated with increased areas of WMH may be suggestive of demyelination and axonal damage due to generalised cerebral vascular disease. (orig.)

  11. Description of Karaganops n. gen. perratus (Daniltshenko 1970) with otoliths in situ, an endemic Karaganian (Middle Miocene) herring (Clupeidae) in the Eastern Paratethys

    DEFF Research Database (Denmark)

    Baykina, Eugenia M.; Schwarzhans, Werner

    2017-01-01

    Karaganops is established as a new fossil genus of the family Clupeidae, subfamily Clupeinae, to encompass the nominal species Sardinella perrata Daniltshenko 1970 from the Karaganian of southern Russia. Karaganops belongs to the group of genera characterized by the presence of two elongated rays...... fossil record reaches back in time to Early Miocene and possibly Late Oligocene in the North Sea Basin....

  12. Myxosporean plasmodial infection associated with ulcerative lesions in young-of-the-year Atlantic menhaden in a tributary of the Chesapeake Bay, and possible links to Kudoa clupeidae

    Science.gov (United States)

    Reimschuessel, R.; Gieseker, C.M.; Driscoll, C.; Baya, A.; Kane, A.S.; Blazer, V.S.; Evans, J.J.; Kent, M.L.; Moran, J.D.W.; Poynton, S.L.

    2003-01-01

    Ulcers in Atlantic menhaden Brevoortia tyrannus (Latrobe) (Clupeidae), observed along the USA east coast, have been attributed to diverse etiologies including bacterial, fungal and, recently, harmful algal blooms. To understand the early pathogenesis of these lesions, we examined juvenile Atlantic menhaden collected during their seasonal presence in Chesapeake Bay tributaries from April to October 1999 and from March to August 2000. We conducted histopathological examinations of young-of-the-year fish from the Pocomoke River tributary, which has a history of fish mortalities and high lesion prevalence. Kudoa clupeidae (Myxozoa: Myxosporea) spores were present in the muscles of fish collected in both years. Of the fish assessed by histology in April, 5 to 14% were infected, while in May 90 to 96% were infected. Infection rates remained high during the summer. Mature spores were primarily located within myomeres and caused little or no observable pathological changes. Ultrastructure showed spores with capsulogenic cells bearing filamentous projections, and a basal crescentic nucleus with mottled nucleoplasm containing cleaved, condensed chromatin. Also, a highly invasive plasmodial stage of a myxozoan was found in the lesions of juvenile Atlantic menhaden. The plasmodia were observed in fish collected between May and July, with the maximum occurrence in late June 1999 and late May 2000. Plasmodia penetrated and surrounded muscle bundles, causing grossly observable raised lesions in 73% of all fish infected with this invasive stage. Plasmodia were also detected in the visceral organs, branchial arches, and interocular muscles of some fish. Some of the invasive extrasporogonic plasmodial lesions were associated with ulcers and chronic inflammatory infiltrates. The plasmodial stage appeared to slough out of the tissue with subsequent evidence of wound healing. Ultrastructure showed plasmodia with an elaborate irregular surface, divided into distinct ectoplasm and

  13. Experimental mouse model of optic neuritis with inflammatory demyelination produced by passive transfer of neuromyelitis optica-immunoglobulin G

    Science.gov (United States)

    2014-01-01

    Background Although optic neuritis (ON) is a defining feature of neuromyelitis optica (NMO), appropriate animal models of NMO ON are lacking. Most NMO patients are seropositive for immunoglobulin G autoantibodies (NMO-IgG) against the astrocyte water channel aquaporin-4 (AQP4). Methods Several approaches were tested to develop a robust, passive-transfer mouse model of NMO ON, including NMO-IgG and complement delivery by: (i) retrobulbar infusion; (ii) intravitreal injection; (iii) a single intracranial injection near the optic chiasm; and (iv) 3-days continuous intracranial infusion near the optic chiasm. Results Little ON or retinal pathology was seen using approaches (i) to (iii). Using approach (iv), however, optic nerves showed characteristic NMO pathology, with loss of AQP4 and glial fibrillary acidic protein immunoreactivity, granulocyte and macrophage infiltration, deposition of activated complement, demyelination and axonal injury. Even more extensive pathology was created in mice lacking complement inhibitor protein CD59, or using a genetically modified NMO-IgG with enhanced complement effector function, including significant loss of retinal ganglion cells. In control studies, optic nerve pathology was absent in treated AQP4-deficient mice, or in wild-type mice receiving control (non-NMO) IgG and complement. Conclusion Passive transfer of NMO-IgG and complement by continuous infusion near the optic chiasm in mice is sufficient to produce ON with characteristic NMO pathology. The mouse model of NMO ON should be useful in further studies of NMO pathogenesis mechanisms and therapeutics. PMID:24468108

  14. Imaging of the optic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Minerva [Head and Neck and Maxillofacial Radiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland)], E-mail: minerva.becker@hcuge.ch; Masterson, Karen [Head and Neck and Maxillofacial Radiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Delavelle, Jacqueline [Neuroradiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Viallon, Magalie [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Vargas, Maria-Isabel [Neuroradiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Becker, Christoph D. [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland)

    2010-05-15

    This article provides an overview of the imaging findings of diseases affecting the optic nerve with special emphasis on clinical-radiological correlation and on the latest technical developments in MR imaging and CT. The review deals with congenital malformations, tumors, toxic/nutritional and degenerative entities, inflammatory and infectious diseases, compressive neuropathy, vascular conditions and trauma involving the optic nerve from its ocular segment to the chiasm. The implications of imaging findings on patient management and outcome and the importance of performing high-resolution tailored examinations adapted to the clinical situation are discussed.

  15. Imaging of the optic nerve

    International Nuclear Information System (INIS)

    Becker, Minerva; Masterson, Karen; Delavelle, Jacqueline; Viallon, Magalie; Vargas, Maria-Isabel; Becker, Christoph D.

    2010-01-01

    This article provides an overview of the imaging findings of diseases affecting the optic nerve with special emphasis on clinical-radiological correlation and on the latest technical developments in MR imaging and CT. The review deals with congenital malformations, tumors, toxic/nutritional and degenerative entities, inflammatory and infectious diseases, compressive neuropathy, vascular conditions and trauma involving the optic nerve from its ocular segment to the chiasm. The implications of imaging findings on patient management and outcome and the importance of performing high-resolution tailored examinations adapted to the clinical situation are discussed.

  16. Radiation optic neuropathy

    International Nuclear Information System (INIS)

    Kline, L.B.; Kim, J.Y.; Ceballos, R.

    1985-01-01

    Following surgery for pituitary adenoma, radiation therapy is an accepted treatment in reducing tumor recurrence. However, a potential therapeutic complication is delayed radionecrosis of perisellar neural structures, including the optic nerves and chiasm. This particular cause of visual loss, radiation optic neuropathy (RON), has not been emphasized in the ophthalmologic literature. Four cases of RON seen in the past five years are reported. Diagnostic criteria include: (1) acute visual loss (monocular or binocular), (2) visual field defects indicating optic nerve or chiasmal dysfunction, (3) absence of optic disc edema, (4) onset usually within three years of therapy (peak: 1-1 1/2 years), and (5) no computed tomographic evidence of visual pathway compression. Pathologic findings, differential diagnosis and therapy will be discussed in outlining the clinical profile of RON

  17. [Risk factors of postoperative meningitis in patients with chiasm-sellar tumors].

    Science.gov (United States)

    Popugaev, K A; Savin, I A; Ershova, O N; Kurdyumova, N V; Tabasaransky, T F; Oshorov, A V; Kadashev, B A; Kalinin, P L; Kutin, M A

    2014-01-01

    Postoperative intracranial infectious complications are one of the most topical problems of neurosurgical intensive care due to theirs significant capability to impair outcomes of the main disease. To define the risk factors of postoperative meningitis in patients with chiasm-sellar tumors. 1. to define the effect of somatic and intracranial risk factors on occurrence of postoperative meningitis in patients after transsphenoidal and transcranial approaches to the tumor. 2. To define the effect of postoperative meningitis on outcomes of treatment in patients after transsphenoidal and transcranial approaches to the tumor. Somatic and intracranial risk factors of occurrence of postoperative meningitis (pneumonia, urinary tract infection, sepsis, intra-abdominal hypertension, the presence of external ventricular and lumbar drainage, monitoring of intracranial pressure, cerebrospinal fluid, and reoperation) were fixed every day. The study was conducted in the ICU of the Burdenko from October, 2010 to July, 2012. The 34 patients (19 males, 15 females) were included in the study (average age 47.5 years). The patients were divided into two groups; 17 patients each group. The group-1 included patients after transcranial approach to the tumor and the group-2 included patients after transsphenoidal approach. In the group-1 a meningitis occurred in 3 patients (17.6% +/- 9.2%, DI [-0.4 - 35.6]). In the group-2 a meningitis occurred in 7 patients (41.2% +/- 11.9) DI 95% [17.8 - 64.4]. Accumulation of cerebrospinal fluid under the skin flap authentically increased a risk of a meningitis occurrence in patients after transcranial approach to the tumor (p = 0.031). There was no defined statistical significance of other risk factors. But there was defined a trend of the increasing of meningitis occurrence in patients after transsphenoidal approach in case of lumbar drainage or reoperation. Duration of mechanical ventilation and ICU stay in patients with meningitis was authentically

  18. A case of radiation optic neuropathy after irradiation for pituitary adenoma

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Masahiro; Sasaki, Ushio; Shinohara, Nobuya; Takeda, Tetsuji; Chaki, Takanori; Nishigakiuchi, Keiji; Kusunoki, Katsusuke (Ehime Prefectural Central Hospital, Matsuyama (Japan))

    1992-05-01

    A 60-year-old woman with radiation optic neuropathy 21 months after irradiation is reported. The patient received a total dose of 50 Gy in 25 fractions for 39 days for pituitary adenoma. She presented with bitemporal hemianopsia and loss of recent memory. Gadolinium-enhanced T1-weighted imaging was very useful for detecting lesions in the optic nerves and chiasm to the hypothalamus including mamillary bodies. Two-month steroid therapy was effective in preventing the disease progression, although visual loss and loss of recent memory were not improved. (N.K.).

  19. A case of radiation optic neuropathy after irradiation for pituitary adenoma

    International Nuclear Information System (INIS)

    Ohta, Masahiro; Sasaki, Ushio; Shinohara, Nobuya; Takeda, Tetsuji; Chaki, Takanori; Nishigakiuchi, Keiji; Kusunoki, Katsusuke

    1992-01-01

    A 60-year-old woman with radiation optic neuropathy 21 months after irradiation is reported. The patient received a total dose of 50 Gy in 25 fractions for 39 days for pituitary adenoma. She presented with bitemporal hemianopsia and loss of recent memory. Gadolinium-enhanced T1-weighted imaging was very useful for detecting lesions in the optic nerves and chiasm to the hypothalamus including mamillary bodies. Two-month steroid therapy was effective in preventing the disease progression, although visual loss and loss of recent memory were not improved. (N.K.)

  20. Retinal, optic nerve and chiasmal function following radiation therapy demonstrated by visual evoked response testing

    International Nuclear Information System (INIS)

    Soni, A.B.; Constine, L.S.; Smith, D.; Palisca, M.; Ojomo, K.; Muhs, A.

    1997-01-01

    Purpose: To evaluate the tolerance of the retina, optic nerve, and optic chiasm to radiation doses conventionally used to treat patients with primary brain or pituitary tumors and to explore the character of detectable radiation effects. Visual evoked response (VER) testing is a noninvasive and sensitive method for identifying radiation injury to the visual system due to alterations in small vessel or myelin integrity. Such evaluations may increase our understanding of the threshold for and the pathogenesis of radiation injury. Materials and Methods: Twenty-four patients irradiated for brain or pituitary tumors between 1972 and 1996 had VER testing. Patients were included in study if the retina, optic nerves or chiasm were in the radiation (RT) field. At the time of RT patients ranged in age from 1.5 to 55 years (median 33). Mean doses were as follows: right retina, 29 Gy (range 10 - 60 Gy); left retina, 29.5 Gy (range 10 - 60 Gy); right optic nerve, 42.9 Gy (range 10 - 60 Gy); left optic nerve, 42.6 Gy (range 10 - 60 Gy); and optic chiasm, 48.2 Gy (range 10 - 65 Gy). Daily fractionation ranged from 1.5 to 1.8 Gy. Pattern VER testing distinguishes compressive or ischemic effects of tumor on the visual system from radiation retinopathy or optic neuropathy on the basis of the conduction amplitude and delay pattern. Prechiasm, chiasm, and postchiasm injuries are distinguishable by analyzing VER changes. Four evoked responses were obtained for each eye, each representing the average of 100 stimulus reversals. Results: VER was normal in 11 patients and abnormal in 13 patients. Only 2 patients (8%) had VER evidence of radiation injury to the visual system, one of whom had visual compromise. The other 11 abnormal patients had characteristic VER changes attributable to tumor or surgical damage. There was no significant difference in the radiation doses given to any subgroup. The one patient with radiation retinopathy had received 55-60 Gy to the posterior globe. Ten years

  1. Prostate Dose Escalation by a Innovative Inverse Planning-Driven IMRT

    Science.gov (United States)

    2008-11-01

    sessions for the parotid gland, optic track, and the temporal lobe when they were in extreme proximity with the PTV. The comparisons of the dose...gross target volume; L = left; OC = optic chiasm; ON = optic nerve; PARO = parotid gland; pCT = planning computed tomography; PTV = planning target...chiasm/nerves, optic lens, left parotid , larynx and spinal cord. The mandible and right parotid were not used because these structures significantly

  2. Neuromyelitis optica IgG in the cerebrospinal fluid induces astrocytopathy in optic nerve

    DEFF Research Database (Denmark)

    Soelberg, Kerstin; Lillevang, Søren Thue; Mørch, Marlene

    (anti-CD59a). A total of five mice received AQP4-IgG + C + anti-CD59a, four mice received normal-IgG + C + anti-CD59a, four mice received AQP4-IgG+ C and one normal-IgG + C. Mice were killed four days later. The optic nerves were isolated and fixed in paraformaldehyde. Paraffin embedded optic nerves...... was coincident with deposition of complement. Histopathological lesions were markedly enhanced with extensive/long-segment astrocytopathy of optic nerve and optic chiasm involvement in AQP4- IgG+ C + anti-CD59a treated mice. Such pathology was not seen in mice receiving normal human IgG, C and anti-CD59a...

  3. Blindness associated with nasal/paranasal lymphoma in a stallion.

    Science.gov (United States)

    Sano, Yuto; Okamoto, Minoru; Ootsuka, Youhei; Matsuda, Kazuya; Yusa, Shigeki; Taniyama, Hiroyuki

    2017-03-23

    A 29-year-old stallion presented with bilateral blindness following the chronic purulent nasal drainage. The mass occupied the right caudal nasal cavity and right paranasal sinuses including maxillary, palatine and sphenoidal sinuses, and the right-side turbinal and paranasal septal bones, and cribriform plate of ethmoid bone were destructively replaced by the mass growth. The right optic nerve was invaded and involved by the mass, and the left optic nerve and optic chiasm were compressed by the mass which was extended and invaded the skull base. Histologically, the optic nerves and optic chiasm were degenerated, and the mass was diagnosed as lymphoma which was morphologically and immunohistochemically classified as a diffuse large B-cell lymphoma. Based on these findings, the cause of the blindness in the stallion was concluded to be due to the degeneration of the optic nerves and chiasm associated with lymphoma occurring in the nasal and paranasal cavities. To the best of our knowledge, this is the first report of the equine blindness with optic nerve degeneration accompanied by lymphoma.

  4. Magnetic resonance imaging (MRI) in the diagnosis of optic neuritis and neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kojima, Shigeyuki; Hirayama, Keizo

    1989-02-01

    Magnetic resonance imaging (MRI) was performed in thirty patients who had been suffering from optic neuritis (ON). Twenty-one cases were caused by multiple sclerosis (MS) and in 9 cases the causes been defined. In MRI, abnormalities were found in 17 out of 21 MS cases in several places such as near the ventricles, mid-brain, spinal cord etc. Increased signals from the optic chiasm to optic radiation were found in 5 cases. However, abnormal MRI findings did not always correspond to Goldmann visual field defects. In 3 out of 9 cases of ON with unknown causes, high signals in the white matter of the brain were found, and it was suggested that those may develop to MS. MRI was, thus, proved to be very useful for the diagnois of MS.

  5. Magnetic resonance imaging (MRI) in the diagnosis of optic neuritis and neuropathy

    International Nuclear Information System (INIS)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) was performed in thirty patients who had been suffering from optic neuritis (ON). Twenty-one cases were caused by multiple sclerosis (MS) and in 9 cases the causes been defined. In MRI, abnormalities were found in 17 out of 21 MS cases in several places such as near the ventricles, mid-brain, spinal cord etc. Increased signals from the optic chiasm to optic radiation were found in 5 cases. However, abnormal MRI findings did not always correspond to Goldmann visual field defects. In 3 out of 9 cases of ON with unknown causes, high signals in the white matter of the brain were found, and it was suggested that those may develop to MS. MRI was, thus, proved to be very useful for the diagnois of MS. (author)

  6. Controversy in the management of optic nerve glioma

    International Nuclear Information System (INIS)

    Weiss, L.; Sagerman, R.H.; King, G.A.; Chung, C.T.; Dubowy, R.L.

    1987-01-01

    The records of 16 patients with optic nerve glioma treated between 1961 and 1984 were reviewed. All patients except two had extension of tumor beyond the chiasm to the hypothalamus, adjacent brain and/or along the posterior optic tract. Eleven of 16 cases were biopsy-proven, two patients had craniotomy and visual inspection but no biopsy was performed, and in two cases the biopsy was not diagnostic. Fourteen patients received radiation therapy, usually consisting of 50 Gy in 5 weeks (range 40-56 Gy), one patient was treated surgically and one with chemotherapy. With a follow-up of 1 to 20 years, 7 of the 14 patients irradiated are alive, three patients are dead of disease at 3, 6 and 9 years post-treatment, three were lost to follow-up at 1, 8, and 8 years, and one is dead of intercurrent disease at 5.5 years. Overall vision was improved in five patients and stable in seven following treatment. In two patients, vision could not be evaluated because of young age at presentation. Four patients had recurrences. One was retreated with 30 Gy in 3 weeks and shows no evidence of disease at 20 years. The three other patients died of their disease. There is controversy over the best treatment for these patients. Based on these results and a review of the literature, the authors recommendation is to irradiate tumors with extension beyond the chiasm at the time of presentation rather than waiting for increasing symptoms because function that is lost may not always be recovered. Chemotherapy needs to be further investigated but holds promise, especially for the younger children

  7. Optic nerve hypoplasia

    Directory of Open Access Journals (Sweden)

    Savleen Kaur

    2013-01-01

    Full Text Available Optic nerve hypoplasia (ONH is a congenital anomaly of the optic disc that might result in moderate to severe vision loss in children. With a vast number of cases now being reported, the rarity of ONH is obviously now refuted. The major aspects of ophthalmic evaluation of an infant with possible ONH are visual assessment, fundus examination, and visual electrophysiology. Characteristically, the disc is small, there is a peripapillary double-ring sign, vascular tortuosity, and thinning of the nerve fiber layer. A patient with ONH should be assessed for presence of neurologic, radiologic, and endocrine associations. There may be maternal associations like premature births, fetal alcohol syndrome, maternal diabetes. Systemic associations in the child include endocrine abnormalities, developmental delay, cerebral palsy, and seizures. Besides the hypoplastic optic nerve and chiasm, neuroimaging shows abnormalities in ventricles or white- or gray-matter development, septo-optic dysplasia, hydrocephalus, and corpus callosum abnormalities. There is a greater incidence of clinical neurologic abnormalities in patients with bilateral ONH (65% than patients with unilateral ONH. We present a review on the available literature on the same to urge caution in our clinical practice when dealing with patients with ONH. Fundus photography, ocular coherence tomography, visual field testing, color vision evaluation, neuroimaging, endocrinology consultation with or without genetic testing are helpful in the diagnosis and management of ONH. (Method of search: MEDLINE, PUBMED.

  8. MRI of pituitary adenomas following treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Athanassopoulou, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Rologis, D. [Neurosurgical Clinic, Athens General Hospital (Greece); Kalovidouris, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Kotoulas, G. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Vlahos, L. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Papavassiliou, C. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece)

    1993-10-01

    The purpose of this study was to assess pituitary adenomas following surgical and/or medical treatment in 28 patients. All patients were evaluated with both computed tomography (CT) and magnetic resonance imaging (MRI). The results were correlated with the clinical findings. Apart from the visualization of the adenoma itself (either residual or recurrent) other findings and in particular, morphological changes of the optic chiasm, the pituitary stalk and the sellar floor were evaluated with both imaging modalities. By comparing the two imaging modalities it was found that MRI was superior to CT in demonstrating residual/recurrent adenoma as well as evaluating the morphological changes of the optic chiasm and optic nerves. CT was superior or equal to MR in demonstrating the sellar floor changes. The intra-operatively implanted fat was equally seen by CT and MR. In conclusion, the anatomical variations of the optic chiasm and pituitary stalk are better visualized by MRI and allow a more precise evaluation of changes attributed to surgical or medical treatment of pituitary adenomas. (orig.)

  9. MRI of pituitary adenomas following treatment

    International Nuclear Information System (INIS)

    Gouliamos, A.; Athanassopoulou, A.; Rologis, D.; Kalovidouris, A.; Kotoulas, G.; Vlahos, L.; Papavassiliou, C.

    1993-01-01

    The purpose of this study was to assess pituitary adenomas following surgical and/or medical treatment in 28 patients. All patients were evaluated with both computed tomography (CT) and magnetic resonance imaging (MRI). The results were correlated with the clinical findings. Apart from the visualization of the adenoma itself (either residual or recurrent) other findings and in particular, morphological changes of the optic chiasm, the pituitary stalk and the sellar floor were evaluated with both imaging modalities. By comparing the two imaging modalities it was found that MRI was superior to CT in demonstrating residual/recurrent adenoma as well as evaluating the morphological changes of the optic chiasm and optic nerves. CT was superior or equal to MR in demonstrating the sellar floor changes. The intra-operatively implanted fat was equally seen by CT and MR. In conclusion, the anatomical variations of the optic chiasm and pituitary stalk are better visualized by MRI and allow a more precise evaluation of changes attributed to surgical or medical treatment of pituitary adenomas. (orig.)

  10. Radiotherapeutic management of optic nerve gliomas in children

    International Nuclear Information System (INIS)

    Danoff, B.F.; Kramer, S.; Thompson, N.

    1980-01-01

    Optic nerve gliomas represent one to five percent of all intracranial tumors in children. The management of these tumors remains controversial. From 1956 to 1977, 18 children with optic nerve gliomas were treated at Thomas Jefferson University Hospital using external beam radiotherapy. All children presented with decreased visual acuity and five of eighteen were blind in one eye. No patient was found to have involvement of a single optic nerve. in eight patients, the chiasm was involved, in ten patients, tumor had extended to the frontal lobes and/or hypothalamus. Initial surgical management included biopsy only in seven patients, inspection of tumor in two patients and partial excision in seven patients. Two patients were treated with radiotherapy based on radiological findings. A tumor dose of 5000 to 6000 rad was given in 5.5 to 6.5 weeks. Stabilization of visual impairment or improvement in vision was noted in 78 percent of patients who were evaluable. The ten year survival was 73 percent. Radiological evidence of tumor regression will be presented. It is our impression that radiotherapy is indicated in the treatment of children with optic nerve gliomas who have poor prognostic signs

  11. Nonthermal ablation with microbubble-enhanced focused ultrasound close to the optic tract without affecting nerve function.

    Science.gov (United States)

    McDannold, Nathan; Zhang, Yong-Zhi; Power, Chanikarn; Jolesz, Ferenc; Vykhodtseva, Natalia

    2013-11-01

    Tumors at the skull base are challenging for both resection and radiosurgery given the presence of critical adjacent structures, such as cranial nerves, blood vessels, and brainstem. Magnetic resonance imaging-guided thermal ablation via laser or other methods has been evaluated as a minimally invasive alternative to these techniques in the brain. Focused ultrasound (FUS) offers a noninvasive method of thermal ablation; however, skull heating limits currently available technology to ablation at regions distant from the skull bone. Here, the authors evaluated a method that circumvents this problem by combining the FUS exposures with injected microbubble-based ultrasound contrast agent. These microbubbles concentrate the ultrasound-induced effects on the vasculature, enabling an ablation method that does not cause significant heating of the brain or skull. In 29 rats, a 525-kHz FUS transducer was used to ablate tissue structures at the skull base that were centered on or adjacent to the optic tract or chiasm. Low-intensity, low-duty-cycle ultrasound exposures (sonications) were applied for 5 minutes after intravenous injection of an ultrasound contrast agent (Definity, Lantheus Medical Imaging Inc.). Using histological analysis and visual evoked potential (VEP) measurements, the authors determined whether structural or functional damage was induced in the optic tract or chiasm. Overall, while the sonications produced a well-defined lesion in the gray matter targets, the adjacent tract and chiasm had comparatively little or no damage. No significant changes (p > 0.05) were found in the magnitude or latency of the VEP recordings, either immediately after sonication or at later times up to 4 weeks after sonication, and no delayed effects were evident in the histological features of the optic nerve and retina. This technique, which selectively targets the intravascular microbubbles, appears to be a promising method of noninvasively producing sharply demarcated lesions in

  12. Radiation-induced optic neuropathy: A magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Guy, J.; Mancuso, A.; Beck, R.; Moster, M.L.; Sedwick, L.A.; Quisling, R.G.; Rhoton, A.L. Jr.; Protzko, E.E.; Schiffman, J.

    1991-01-01

    Optic neuropathy induced by radiation is an infrequent cause of delayed visual loss that may at times be difficult to differentiate from compression of the visual pathways by recurrent neoplasm. The authors describe six patients with this disorder who experienced loss of vision 6 to 36 months after neurological surgery and radiation therapy. Of the six patients in the series, two had a pituitary adenoma and one each had a metastatic melanoma, multiple myeloma, craniopharyngioma, and lymphoepithelioma. Visual acuity in the affected eyes ranged from 20/25 to no light perception. Magnetic resonance (MR) imaging showed sellar and parasellar recurrence of both pituitary adenomas, but the intrinsic lesions of the optic nerves and optic chiasm induced by radiation were enhanced after gadolinium-diethylenetriaminepenta-acetic acid (DTPA) administration and were clearly distinguishable from the suprasellar compression of tumor. Repeated MR imaging showed spontaneous resolution of gadolinium-DTPA enhancement of the optic nerve in a patient who was initially suspected of harboring recurrence of a metastatic malignant melanoma as the cause of visual loss. The authors found the presumptive diagnosis of radiation-induced optic neuropathy facilitated by MR imaging with gadolinium-DTPA. This neuro-imaging procedure may help avert exploratory surgery in some patients with recurrent neoplasm in whom the etiology of visual loss is uncertain

  13. Interleaved 3D-CNNs for joint segmentation of small-volume structures in head and neck CT images.

    Science.gov (United States)

    Ren, Xuhua; Xiang, Lei; Nie, Dong; Shao, Yeqin; Zhang, Huan; Shen, Dinggang; Wang, Qian

    2018-02-26

    Accurate 3D image segmentation is a crucial step in radiation therapy planning of head and neck tumors. These segmentation results are currently obtained by manual outlining of tissues, which is a tedious and time-consuming procedure. Automatic segmentation provides an alternative solution, which, however, is often difficult for small tissues (i.e., chiasm and optic nerves in head and neck CT images) because of their small volumes and highly diverse appearance/shape information. In this work, we propose to interleave multiple 3D Convolutional Neural Networks (3D-CNNs) to attain automatic segmentation of small tissues in head and neck CT images. A 3D-CNN was designed to segment each structure of interest. To make full use of the image appearance information, multiscale patches are extracted to describe the center voxel under consideration and then input to the CNN architecture. Next, as neighboring tissues are often highly related in the physiological and anatomical perspectives, we interleave the CNNs designated for the individual tissues. In this way, the tentative segmentation result of a specific tissue can contribute to refine the segmentations of other neighboring tissues. Finally, as more CNNs are interleaved and cascaded, a complex network of CNNs can be derived, such that all tissues can be jointly segmented and iteratively refined. Our method was validated on a set of 48 CT images, obtained from the Medical Image Computing and Computer Assisted Intervention (MICCAI) Challenge 2015. The Dice coefficient (DC) and the 95% Hausdorff Distance (95HD) are computed to measure the accuracy of the segmentation results. The proposed method achieves higher segmentation accuracy (with the average DC: 0.58 ± 0.17 for optic chiasm, and 0.71 ± 0.08 for optic nerve; 95HD: 2.81 ± 1.56 mm for optic chiasm, and 2.23 ± 0.90 mm for optic nerve) than the MICCAI challenge winner (with the average DC: 0.38 for optic chiasm, and 0.68 for optic nerve; 95HD: 3.48 for

  14. Diet composition of the round sardinella Sardinella aurita Valenciennes, 1847 (Osteichthyes: Clupeidae in the Turkish Aegean Sea

    Directory of Open Access Journals (Sweden)

    Bahar Bayhan

    2015-12-01

    Full Text Available Sardinella aurita, a round sardinella from Clupeidae family, is a pelagic fish found in tropical and temperate seas, just like other members of its family. The species has a wide distribution and its contribution to Mediterranean and international fisheries production potential is high. In Turkey, this species has a wide distribution in the Mediterranean Sea and the Aegean Sea, on the other hand, it is rarely seen in the Black Sea and Marmara Sea. Apart from its economic contribution to the world fisheries industry, the species has an important role in the food chain in regions it is found as it takes part in diet composition of its predators such as greater amberjack, and common dolphinfish. Nowadays, trophic levels are used in order to develop ecosystem based fisheries management strategies. For this purpose, diet composition of the round sardinella was investigated. Samples were obtained from commercial fishermen, who generally use purse seine and gill nets in Izmir Bay concerned during October 2010 - September 2011. A total of 434 S. aurita were collected all year round, with total lengths ranging 12.1 to 27.1 cm. Fish were dissected immediately after capture, stomachs removed and stored in formalin (10% until the contents were analysed. Stomach contents examined using a SZX7 Olympus stereo microscope. Prey items were identified to the lowest possible taxon. Forty eight species were identified, belonging to six major groups: Polychaeta, Crustacea, Mollusca, Chaetognatha, Tunicate and Teleostei. Finally crustaceans were the most important food item in terms of index of relative importance. At least 31 copepod species were identified, where Calanoida, Oithona nana, Oncaea media and Oithona plumifera appeared all year round with %IRI ≥ 10. With this study, the feeding regime of round sardinella, was identified in detail for the Aegean Sea of Turkey for the first time.

  15. [Gradient-index (GRIN) endoscopic examinations from the inner structures of the optic nerve meninges].

    Science.gov (United States)

    Sens, Frank Michael; Killer, Hanspeter Esriel; Meyer, Peter

    2003-03-01

    Due to the excellent image quality and the small outer diameter of the GRIN-(gradient index) endoscope tips we were able to examine the subdural and the subarachnoidal space of the optic nerve meninges by endoscopy. This examination was performed to obtain more information about the inner structure of the optic nerve meninges. In this post-mortem study 7 optic nerves were examined from the chiasm to the globe by GRIN endoscopy (Volpi, Schlieren, Switzerland), with an outer diameter of 0.89 mm, integrated optic of 0.5 mm diameter and an integrated fluid channel of 0.2 mm diameter. In all cases the endoscopic examination of the optic nerve meninges was technically easy to perform. It was possible to study the inner surface of the nerve sheaths and the nerve sheath spaces in close-up. We found horizontal and vertical cords on the inner surface of the dura mater, which could tighten by movements of the optic nerve. With a gradient-index (GRIN) endoscope we obtained new information about the inner structure of the optic nerve meninges. New theories about the changes of the optic nerve meninges during movements of the optic nerve may evolve from this study. Further studies with this new method should be encouraged.

  16. Postraumatic delayed loss of vision

    International Nuclear Information System (INIS)

    Partington, C.R.; Graves, V.B.; Ruetenacht, D.A.; Weinstein, J.M.; Strother, C.M.

    1989-01-01

    The imaging studies and clinical findings in 10 patients who suffered delayed vision loss beginning 1 day to 13 years after head trauma have been reviewed. Two different primary lesions could be identified: pseudoaneurysm of the internal carotid artery and carotid cavernous fistula. The pathologic changes associated with pseudoaneurysm included compression of the optic nerves and/or chiasm by arterial aneurysm and intracranial hematoma. Carotid cavernous fistula caused delayed vision loss by compression of the optic nerves and chiasm by saccular dilatation of the cavernous sinus and by abnormal orbital venous drainage with retinal venous stasis, retinal edema, and glaucoma

  17. MELATONIN SECRETION AND HYPERSOMNIA IN CHILDREN AND ADOLESCENTS AFTER CRANIOPHARYNGIOMA RESECTION

    Directory of Open Access Journals (Sweden)

    E. Yu. Il'ina

    2012-01-01

    Full Text Available Craniopharyngioma is a rare embryonic tumor of the chiasm-sellar region with low malignancy rate but high frequency of recurrence. In spite of the favorable outcome and satisfactory results of treatment the patients quality of life worsens due to complications associated with anatomic localization of craniopharyngioma close to the optic nerve, optic chiasm, hypophysis and hypothalamus. The development of hypothalamic obesity is observed in 25–60% of children and adolescents after surgical treatment of craniopharyngioma, which is usually accompanied with significant disturbances of circadian rhythm and has the most important influence on patients quality of life.

  18. 3DCRT for posterior fossa: Sparing of surrounding organs at risk

    African Journals Online (AJOL)

    Azza Helal

    2013-06-25

    Jun 25, 2013 ... including non-posterior fossa brain, pituitary, cochlea, eyes, optic nerves, optic chiasm, ... grams; Rt.C, right cochlea; Lt. C, left cochlea; Non P.F, non posterior ... child's cognitive function and quality of life.6 Although the.

  19. WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

    International Nuclear Information System (INIS)

    Milano, M.

    2015-01-01

    in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest

  20. WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Milano, M. [University of Rochester Medical Center (United States)

    2015-06-15

    in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

  1. Reversible Edema-Like Changes Along the Optic Tract Following Pipeline-Assisted Coiling of a Large Anterior Communicating Artery Aneurysm.

    Science.gov (United States)

    La Pira, Biagia; Brinjikji, Waleed; Hunt, Christopher; Chen, John J; Lanzino, Giuseppe

    2017-06-01

    Aneurysmal volume expansion after endovascular treatment is caused by intra-aneurysmal thrombosis in the early postembolization period. Although postembolization mass effect on cranial nerves and other adjacent structures has been previously reported, we are unaware of reports involving the anterior visual pathway. A 66-year-old woman with a 2-week history of blurred vision without headache was found to have a large, unruptured anterior communicating artery aneurysm. One month after endovascular treatment of the aneurysm with coiling and flow diversion, the patient developed decreased vision in her right eye and a left homonymous hemianopia. Magnetic resonance imaging demonstrated compression of the right optic nerve, chiasm, and edema of the right optic tract. The patient was treated with a course of high dose corticosteroids, and over the course of several weeks, her vision improved and the optic tract edema resolved. We alert clinicians to this rare but potentially reversible visual complication of endovascular treatment of intracranial aneurysms.

  2. MRI findings and correlative study of MRI and visual evoked potentials in optic neuritis

    International Nuclear Information System (INIS)

    Yan Fei; Li Jing; Wang Zhenchang; Liu Shoubin; Zhang Xiaojun

    2008-01-01

    Objective: To investigate the effective MRI sequences and describe the correlation between MRI and visual evoked potential (VEP) in diagnosing optic neuritis. Methods: One hundred and fifty-four eyes with visual impairment of 98 patients with diagnoses of optic neuritis, papillitis, multiple sclerosis and Devic's disease underwent MRI and VEP examination. The MRI findings were analyzed and correlated with VEP results and clinical presentation by using X 2 test, wilco xon test and Kappa test. Results Out of the 154 sick eyes, 56 eyes presented thickened optic nerves, 76 eyes had normal diameter of the optic nerve, and 22 eyes had thin optic nerves. A total of 132 optic nerves showed abnormally high signal in STIR sequences, including involvement of intraocular segment in 7, intraorbital segment in 1.35, intracanalicular segment in 109, intracranial segment in 97, optic chiasm in 56, and optic tract in 23. A total of 54 patients underwent postcontrast MRI. Seventy-four optic nerves of 87 eyes showed enhancement. Among the 196 eyes of 98 patients, 132 eyes presented visual impairment and simultaneous abnormal MR signal of the optic nerve, and 26 eyes had both normal vision and normal MR signal of optic nerve. The consistency of MRI findings and vision status was 80. 61% (Kappa 0.453,P 1 -weighted MR sequence combined with fat- suppression are helpful in diagnosis of optic neuritis. VEP is helpful in diagnosing optic neuritis and in finding subclinical visual problem. The MRI combined with VEP could improve the diagnostic accuracy of optic neuritis. (authors)

  3. Single-session Gamma Knife radiosurgery for optic pathway/hypothalamic gliomas.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2016-12-01

    OBJECTIVE Because of their critical and central location, it is deemed necessary to fractionate when considering irradiating optic pathway/hypothalamic gliomas. Stereotactic fractionated radiotherapy is considered safer when dealing with gliomas in this location. In this study, the safety and efficacy of single-session stereotactic radiosurgery for optic pathway/hypothalamic gliomas were reviewed. METHODS Between December 2004 and June 2014, 22 patients with optic pathway/hypothalamic gliomas were treated by single-session Gamma Knife radiosurgery. Twenty patients were available for follow-up for a minimum of 1 year after treatment. The patients were 5 to 43 years (median 16 years) of age. The tumor volume was 0.15 to 18.2 cm 3 (median 3.1 cm 3 ). The prescription dose ranged from 8 to 14 Gy (median 11.5 Gy). RESULTS The mean follow-up period was 43 months. Five tumors involved the optic nerve only, and 15 tumors involved the chiasm/hypothalamus. Two patients died during the follow-up period. The tumors shrank in 12 cases, remained stable in 6 cases, and progressed in 2 cases, thereby making the tumor control rate 90%. Vision remained stable in 12 cases, improved in 6 cases, and worsened in 2 cases in which there was tumor progression. Progression-free survival was 83% at 3 years. CONCLUSIONS The initial results indicate that single-session Gamma Knife radiosurgery is a safe and effective treatment option for optic pathway/hypothalamic gliomas.

  4. Anophthalmia in a Wild Eastern Gray Squirrel (Sciurus carolinensis).

    Science.gov (United States)

    Rothenburger, Jamie L; Hartnett, Elizabeth A; James, Fiona M K; Grahn, Bruce H

    2017-10-01

    We describe bilateral true anophthalmia in a juvenile female eastern gray squirrel (Sciurus carolinensis) with histologic confirmation that orbital contents lacked ocular tissues. Additionally, the optic chiasm of the brain was absent and axon density in the optic tract adjacent to the lateral geniculate nucleus was reduced.

  5. Does altered fractionation influence the risk of radiation-induced optic neuropathy?

    International Nuclear Information System (INIS)

    Bhandare, Niranjan; Monroe, Alan T.; Morris, Christopher G.; Bhatti, M. Tariq; Mendenhall, William M.

    2005-01-01

    Purpose: To analyze the parameters that influence the risk of radiation-induced optic neuropathy (RION) after radiotherapy for head-and-neck tumors. Methods and Materials: Between 1964 and 2000, 273 patients with tumors of the nasopharynx, paranasal sinuses, nasal cavity, and hard palate adenoid cystic carcinomas were treated with curative intent and had radiation fields that included the optic nerves and/or chiasm. Patients were followed for at least 1 year after radiotherapy. Results: Radiation-induced optic neuropathy developed in 32 eyes of 24 patients (9%). The 5-year rates of freedom from RION according to the total dose and once- vs. twice-daily fractionation were as follows: ≤63 Gy once daily, 95%; ≤63 Gy twice daily, 98%; >63 Gy once daily, 78%; and >63 Gy twice daily, 91%. Multivariate analysis revealed that the total dose affected the risk of RION (p = 0.0047), with patient age (p = 0.0909), once-daily vs. twice-daily fractionation (p = 0.0684), and overall treatment time (p = 0.0972) were marginally significant. The use of adjuvant chemotherapy did not significantly influence the likelihood of developing RION. Conclusion: The likelihood of developing RION is primarily influenced by the total dose. Hyperfractionation may reduce the risk of experiencing this complication

  6. Septo-optic dysplasia: case report Displasia septo-óptica: relato de caso

    Directory of Open Access Journals (Sweden)

    Paulo de Tarso P. Pierre Filho

    2004-08-01

    Full Text Available The clinical triad of septo-optic dysplasia (SOD comprises the absence of the septum pellucidum, congenital optic nerve dysplasia, and multiple endocrine disorders. When any two of these factors are present, the condition is defined as an incomplete form of SOD. The authors report the case of an incomplete form of SOD in a 9-year-old boy with low vision and nystagmus present from birth. The bilateral ophthalmoscopic examination revealed small papillae with double contour images. Magnetic resonance imaging showed hypoplasia of the optic nerve bilaterally, chiasm and absence of the septum pellucidum.A tríade clínica da displasia septo-óptica (DSO compreende a ausência de septo pelúcido, displasia congênita do nervo óptico e múltiplos defeitos endócrinos. Uma forma incompleta de DSO tem sido reconhecida com dois dos três elementos. Os autores relatam um caso de displasia septo-óptica na forma incompleta em um garoto de 9 anos com baixa visão e nistagmo presentes desde o nascimento. O exame oftalmoscópico revelou papila pequena com imagem em duplo contorno bilateralmente. Ressonância magnética mostrou hipoplasia dos nervos ópticos, quiasma e ausência do septo pelúcido.

  7. Brucellosis of the pituitary region: MRI

    International Nuclear Information System (INIS)

    Ciftci, E.; Erden, I.; Akyar, S.

    1998-01-01

    We report a rare case of neurobrucellosis in a 25-year-old woman with visual impairment, bilateral hearing loss, hyperprolactinaemia and meningitis. MRI revealed a sellar and suprasellar mass with enlargement of the optic chiasm. (orig.)

  8. Brucellosis of the pituitary region: MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ciftci, E.; Erden, I.; Akyar, S. [Department of Radiology, University of Ankara (Turkey)

    1998-06-01

    We report a rare case of neurobrucellosis in a 25-year-old woman with visual impairment, bilateral hearing loss, hyperprolactinaemia and meningitis. MRI revealed a sellar and suprasellar mass with enlargement of the optic chiasm. (orig.) With 1 fig., 6 refs.

  9. Dose-volume complication analysis for visual pathway structures of patients with advanced paranasal sinus tumors

    International Nuclear Information System (INIS)

    Martel, Mary Kaye; Sandler, Howard M.; Cornblath, Wayne T.; Marsh, Lon H.; Hazuka, Mark B.; Roa, Wilson H.; Fraass, Benedict A.; Lichter, Allen S.

    1997-01-01

    Purpose: The purpose of the present work was to relate dose and volume information to complication data for visual pathway structures in patients with advanced paranasal sinus tumors. Methods and Materials: Three-dimensional (3D) dose distributions for chiasm, optic nerve, and retina were calculated and analyzed for 20 patients with advanced paranasal sinus malignant tumors. 3D treatment planning with beam's eye view capability was used to design beam and block arrangements, striving to spare the contralateral orbit (to lessen the chance of unilateral blindness) and frequently the ipsilateral orbit (to help prevent bilateral blindness). Point doses, dose-volume histogram analysis, and normal tissue complication probability (NTCP) calculations were performed. Published tolerance doses that indicate significant risk of complications were used as guidelines for analysis of the 3D dose distributions. Results: Point doses, percent volume exceeding a specified published tolerance dose, and NTCP calculations are given in detail for patients with complications versus patients without complications. Two optic nerves receiving maximum doses below the published tolerance dose sustained damage (mild vision loss). Three patients (of 13) without optic nerve sparing and/or chiasm sparing had moderate or severe vision loss. Complication data, including individual patient analysis to estimate overall risk for loss of vision, are given. Conclusion: 3D treatment planning techniques were used successfully to provide bilateral sparing of the globe for most patients. It was more difficult to spare the optic nerves, especially on the ipsilateral side, when prescription dose exceeded the normal tissue tolerance doses. NTCP calculations may be useful in assessing complication risk better than point dose tolerance criteria for the chiasm, optic nerve, and retina. It is important to assess the overall risk of blindness for the patient in addition to the risk for individual visual pathway

  10. SU-F-T-135: A Retrospective Analysis of the Impact of Range Uncertainty in Brain Patients

    Energy Technology Data Exchange (ETDEWEB)

    Grantham, K; Santanam, L; Goddu, S; Sun, B; Zhang, T; Mutic, S; Robinson, C; Huang, J; Perkins, S; Tsien, C; Bradley, J; Zhao, T [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: We retrospectively evaluate the dosimetric impact of a 3.5% range uncertainty on CTV coverage and normal organ toxicity for a cohort of brain patients. Methods: Twenty treatment plans involving 20 brain cancer patients treated with Mevions S250 were reviewed. Forty uncertain plans were made by changing the ranges in original plans by ±3.5% while keeping all devices unchanged. Fidelity to the original plans was evaluated with gamma index. Changes in generalized equivalent uniform dose (gEUD) were reported for the following structures: CTV coverage, brainstem, optic chiasm, and optic nerves. Comparisons were made by plotting the relevant endpoints from the uncertain plans as a function of the same endpoints from the original clinical plan. Results: Gamma-index analysis resulted in a 50% pass rate of the uncertain plans using a 90% passing rate and 3%/3mm criterion. A 9.5% decrease in the slope of gEUD plot for the CTV was observed for the 3.5% downward range shift. However, the change in slope did not result in a gEUD change greater than 1.1% for the CTV. The slopes of the gEUD plots for normal structures increased by 3.1% 3.9% 2.4% and 0.2% for the chiasm, brainstem, left optic nerve and right optic nerve respectively. The maximum deviation from the gEUD of the clinical plan for normal structures was: 64% in the chiasm, 31% for the brainstem, and 19% for both optic nerves. Conclusion: A retrospective review shows moderate radiobiological impact of range uncertainty in passively scattered proton therapy with sporadic catastrophe. The linear regression analysis on the statistical data indicates a systematic deviation of gEUD from treatment planning in the light of range uncertainty.

  11. A Frontal Lobe Meningioma in a Child Leading to Visual Loss

    Directory of Open Access Journals (Sweden)

    Nedime Sahinoglu-Keşkek

    2015-01-01

    Full Text Available Objective. Meningiomas are benign primary meningeal tumors and are seen rare in children and adolescents. Clinical Presentation and Intervention. A 15-year-old Turkish boy reported a 1-month history of headache and blurred vision in both eyes. His visual acuity was 0.3 in both eyes with papilledema. Magnetic resonance imaging showed a 77×97×77 mm intracranial-extra-axial frontal lesion which compresses the chiasm. He was diagnosed with intracranial meningioma and referred to neurosurgery clinic. Conclusion. Ophthalmologists should be aware of the fact that papilledema and low vision can be caused by an intracranial tumor which compresses optic chiasm.

  12. Pituitary diseases and sleep disorders

    NARCIS (Netherlands)

    Romijn, Johannes A.

    2016-01-01

    Patients with pituitary diseases have decreased quality of life. Sleep disorders are prevalent among patients with pituitary diseases and contribute to decreased quality of life. Patients previously treated for compression of the optic chiasm by surgery, and in some cases postoperative radiotherapy,

  13. Automated retinofugal visual pathway reconstruction with multi-shell HARDI and FOD-based analysis.

    Science.gov (United States)

    Kammen, Alexandra; Law, Meng; Tjan, Bosco S; Toga, Arthur W; Shi, Yonggang

    2016-01-15

    Diffusion MRI tractography provides a non-invasive modality to examine the human retinofugal projection, which consists of the optic nerves, optic chiasm, optic tracts, the lateral geniculate nuclei (LGN) and the optic radiations. However, the pathway has several anatomic features that make it particularly challenging to study with tractography, including its location near blood vessels and bone-air interface at the base of the cerebrum, crossing fibers at the chiasm, somewhat-tortuous course around the temporal horn via Meyer's Loop, and multiple closely neighboring fiber bundles. To date, these unique complexities of the visual pathway have impeded the development of a robust and automated reconstruction method using tractography. To overcome these challenges, we develop a novel, fully automated system to reconstruct the retinofugal visual pathway from high-resolution diffusion imaging data. Using multi-shell, high angular resolution diffusion imaging (HARDI) data, we reconstruct precise fiber orientation distributions (FODs) with high order spherical harmonics (SPHARM) to resolve fiber crossings, which allows the tractography algorithm to successfully navigate the complicated anatomy surrounding the retinofugal pathway. We also develop automated algorithms for the identification of ROIs used for fiber bundle reconstruction. In particular, we develop a novel approach to extract the LGN region of interest (ROI) based on intrinsic shape analysis of a fiber bundle computed from a seed region at the optic chiasm to a target at the primary visual cortex. By combining automatically identified ROIs and FOD-based tractography, we obtain a fully automated system to compute the main components of the retinofugal pathway, including the optic tract and the optic radiation. We apply our method to the multi-shell HARDI data of 215 subjects from the Human Connectome Project (HCP). Through comparisons with post-mortem dissection measurements, we demonstrate the retinotopic

  14. Postoperative follow-up of pituitary adenomas after trans-sphenoidal resection: MRI and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, O. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Mateos, B. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pedraja, R. de la [Servicio de Endocrinologia, Hospital de Cruces, Baracaldo (Spain); Villoria, R. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Hernando, J.I. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pastor, A. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pomposo, I. [Servicio de Neurocirugia, Hospital de Cruces, Baracaldo (Spain); Aurrecoechea, J. [Servicio de Neurocirugia, Hospital de Cruces, Baracaldo (Spain)

    1996-11-01

    Our purpose was to correlate the morphological changes seen on MRI studies of the sellar region after trans-sphenoidal resection of pituitary adenomas with clinical and hormonal studies. Between January 1993 and March 1994, 16 patients with a pituitary adenoma (9 macroadenomas and 7 microadenomas) were subjected to trans-sphenoidal resection and included in a prospective study. The protocol consisted of MRI, hormonal and visual studies at the following times: immediately postoperative (1st week), 1st month, 4th month and 1st year after surgery. The evolution of the contents of the sella turcica (tumour remnant, packing material and gland tissue), effects on the infundibulum, optic chiasm, cavernous sinus and sphenoid sinus were correlated with the clinical and hormonal studies. Stabilisation of the postsurgical changes occurred by the 4th month. Tumour remnants were noted in the immediate postoperative period in macroadenomas. Compression of the infundibulum was the only reliable indicator of possible involvement. Optic chiasm compression, defined as close contact between the chiasm and the tumour, was the only morphological finding that indicated visual impairment. There was no standard repneumatisation pattern in the sphenoid sinus, since mucosal changes resembling sinusitis were one of the postsurgical changes. We found MRI not to be useful for follow-up of microadenomas. (orig.). With 4 figs., 4 tabs.

  15. Postoperative follow-up of pituitary adenomas after trans-sphenoidal resection: MRI and clinical correlation

    International Nuclear Information System (INIS)

    Rodriguez, O.; Mateos, B.; Pedraja, R. de la; Villoria, R.; Hernando, J.I.; Pastor, A.; Pomposo, I.; Aurrecoechea, J.

    1996-01-01

    Our purpose was to correlate the morphological changes seen on MRI studies of the sellar region after trans-sphenoidal resection of pituitary adenomas with clinical and hormonal studies. Between January 1993 and March 1994, 16 patients with a pituitary adenoma (9 macroadenomas and 7 microadenomas) were subjected to trans-sphenoidal resection and included in a prospective study. The protocol consisted of MRI, hormonal and visual studies at the following times: immediately postoperative (1st week), 1st month, 4th month and 1st year after surgery. The evolution of the contents of the sella turcica (tumour remnant, packing material and gland tissue), effects on the infundibulum, optic chiasm, cavernous sinus and sphenoid sinus were correlated with the clinical and hormonal studies. Stabilisation of the postsurgical changes occurred by the 4th month. Tumour remnants were noted in the immediate postoperative period in macroadenomas. Compression of the infundibulum was the only reliable indicator of possible involvement. Optic chiasm compression, defined as close contact between the chiasm and the tumour, was the only morphological finding that indicated visual impairment. There was no standard repneumatisation pattern in the sphenoid sinus, since mucosal changes resembling sinusitis were one of the postsurgical changes. We found MRI not to be useful for follow-up of microadenomas. (orig.). With 4 figs., 4 tabs

  16. Craniopharyngioma causing bilateral vision loss 4 months after unremarkable magnetic resonance imaging of the brain

    Directory of Open Access Journals (Sweden)

    Rainy Betts

    2015-01-01

    Full Text Available A 65-year-old man developed bilateral vision loss 4 months after magnetic resonance imaging demonstrated no lesion in the vicinity of the optic chiasm, hypothalamus, and suprasellar tissues. Repeat computed tomography 3 months later showed a predominantly cystic mass of the suprasellar cistern with extension into the anterior third ventricle, which histologically was a craniopharyngioma. The clinical course of this case fuels the controversy whether craniopharyngiomas arise from embryonic rests or can be acquired. From a clinical perspective, it raises questions about when to obtain imaging studies dedicated to the chiasm and the appropriate interval in which a scan should be repeated to exclude structural causes of bilateral vision loss.

  17. Evaluation of magnocellular pathway abnormalities in schizophrenia: a frequency doubling technology study and clinical implications

    Directory of Open Access Journals (Sweden)

    Fabiana Benites Vaz de Lima

    2013-04-01

    Full Text Available BACKGROUND: Visual processing deficits have been reported for patients with schizophrenia. Previous studies demonstrated differences in early-stage processing of schizophrenics, although the nature, extent, and localization of the disturbance are unknown. The magnocellular and parvocellular visual pathways are associated with transient and sustained channels, but their respective contributions to schizophrenia-related visual deficits remains controversial. PURPOSE: The aim of this study was to evaluate magnocellular dysfunction in schizophrenia using frequency doubling technology. METHODS: Thirty-one patients with schizophrenia and 34 healthy volunteers were examined. Frequency doubling technology testing was performed in one session, consisting of a 15-minute screening strategy followed by the C-20 program for frequency doubling technology. RESULTS: Schizophrenic patients showed lower global mean sensitivity (30,97 ± 2,25 dB compared with controls (32,17 ± 3,08 dB, p<0.009. Although there was no difference in the delta sensitivity of hemispheres, there was a difference in sensitivity analysis of the fibers crossing the optic chiasm, with lower mean sensitivity in the patient group (28,80 dB versus controls (30,66 dB. The difference was higher in fibers that do not cross the optic chiasm, with lower mean sensitivity in patients (27,61 dB versus controls (30,26 dB, p<0.005. CONCLUSIONS: Our results suggest that there are differences between global sensitivity and fiber sensitivity measured by frequency doubling technology. The different sensitivity of fibers that do not cross the optic chiasm is consistent with most current etiological hypotheses for schizophrenia. The decreased sensitivity responses in the optic radiations may significantly contribute to research assessing early-stage visual processing deficits for patients with schizophrenia.

  18. Non-decussating retinal-fugal fibre syndrome. An inborn achiasmatic malformation associated with visuotopic misrouting, visual evoked potential ipsilateral asymmetry and nystagmus

    NARCIS (Netherlands)

    Apkarian, P.; Bour, L. J.; Barth, P. G.; Wenniger-Prick, L.; Verbeeten, B.

    1995-01-01

    We report a newly identified syndrome in which nasal retinal fibres fail to decussate due to the inborn absence of an optic chiasm. Visual evoked potential (VEP) assessment and neuro-opththalmic evaluation in two unrelated, non-albino children revealed the unusual visual pathway anomaly in the form

  19. Intrachiasmatic abscess caused by IgG4-related hypophysitis

    DEFF Research Database (Denmark)

    Hadjigeorgiou, Georgios F; Lund, Eva Løbner; Poulsgaard, Lars

    2017-01-01

    INTRODUCTION: Autoimmune hypophysitis is a rare disease of the pituitary, which may affect vision by inflammation and compression of the optic chiasm. However, intrachiasmatic abscess formation has not been previously reported. METHODS: In this study, we report a case of a 29-year-old female with...

  20. Anatomy and physiology of the afferent visual system.

    Science.gov (United States)

    Prasad, Sashank; Galetta, Steven L

    2011-01-01

    The efficient organization of the human afferent visual system meets enormous computational challenges. Once visual information is received by the eye, the signal is relayed by the retina, optic nerve, chiasm, tracts, lateral geniculate nucleus, and optic radiations to the striate cortex and extrastriate association cortices for final visual processing. At each stage, the functional organization of these circuits is derived from their anatomical and structural relationships. In the retina, photoreceptors convert photons of light to an electrochemical signal that is relayed to retinal ganglion cells. Ganglion cell axons course through the optic nerve, and their partial decussation in the chiasm brings together corresponding inputs from each eye. Some inputs follow pathways to mediate pupil light reflexes and circadian rhythms. However, the majority of inputs arrive at the lateral geniculate nucleus, which relays visual information via second-order neurons that course through the optic radiations to arrive in striate cortex. Feedback mechanisms from higher cortical areas shape the neuronal responses in early visual areas, supporting coherent visual perception. Detailed knowledge of the anatomy of the afferent visual system, in combination with skilled examination, allows precise localization of neuropathological processes and guides effective diagnosis and management of neuro-ophthalmic disorders. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Shh-ushing Midline Crossing through Remote Protein Transport.

    Science.gov (United States)

    Herrera, Eloísa; Sitko, Austen A; Bovolenta, Paola

    2018-01-17

    Shh contributes to neural circuit formation with different mechanisms. In this issue, Peng and colleagues (2018) identify a novel trans-axonal mechanism by which Shh derived from contralateral projecting retinal ganglion cells prevents midline crossing of Boc-expressing ipsilateral axons at the optic chiasm. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. [Estimation of the quality of life 8-year-old child with bilateral anophthalmia].

    Science.gov (United States)

    Sredzińska-Kita, Dorota; Mrugacz, Małgorzata; Bakunowicz-Łazarczyk, Alina

    2009-01-01

    The main aim of our work was to estimate the physical and psychomotor development and the arrangement to the daily life for a 8-year-old girl with inborn bilateral anophthalmia. The basic ophthalmic, pediatric and neurological examinations were performed with additional genetic and radiological examinations. The ophthalmic and MRI examination find out the absence of the eyeballs, optic nerves, optic chiasm, optic tracts and optic radiation. Anophthalmia limits in a big grade an independent life of the child. However, currently the girl's development indicates for good intellectual abilities what is promising for future independent life and professional work.

  3. Visual stimulation, {sup 1}H MR spectroscopy and fMRI of the human visual pathways

    Energy Technology Data Exchange (ETDEWEB)

    Boucard, Christine C.; Cornelissen, Frans W. [University of Groningen, Laboratory for Experimental Ophthalmology, Postbus 30001, Groningen (Netherlands); University of Groningen, BCN Neuro-imaging Center, Postbus 196, Groningen (Netherlands); Mostert, Jop P.; Keyser, Jacques De [University Hospital Groningen, Department of Neurology, Groningen (Netherlands); Oudkerk, Matthijs; Sijens, Paul E. [University Hospital Groningen, Department of Radiology, Groningen (Netherlands)

    2005-01-01

    The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). {sup 1}H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were performed in four subjects at an echo time of 135 ms. Functional MRI (fMRI) was used to confirm the presence of activity in the visual cortex during the visual stimulation. Spectral maps of optical chiasm were of poor quality due to field disturbances caused by nearby large blood vessels and/or eye movements. The optic radiations and the occipital lobe did not show any significant MR spectral change upon visual stimulation, i.e., the peak areas of inositol, choline, creatine, glutamate and N-acetylaspartate were not affected. Reproducible lactate signals were not observed. fMRI confirmed the presence of strong activations in stimulated visual cortex. Prolonged visual stimulation did not cause significant changes in MR spectra. Any signal observed near the 1.33 ppm resonance frequency of the lactate methyl-group was artifactual, originating from lipid signals from outside the volume of interest (VOI). Previous claims about changes in lactate levels in the visual cortex upon visual stimulation may have been based on such erroneous observations. (orig.)

  4. Loss of vision: imaging the visual pathways

    International Nuclear Information System (INIS)

    Jaeger, H.R.

    2005-01-01

    This is an overview of diseases presenting with visual impairment, which aims to provide an understanding of the anatomy and pathology of the visual pathways. It discusses the relevant clinical background and neuroimaging findings on CT and standard and advanced MRI of diseases affecting the globe; optic nerve/sheath complex; optic chiasm, tract and radiation; and visual cortex. The overview covers common tumours, trauma, inflammatory and vascular pathology, and conditions such as benign intracranial hypertension and posterior reversible leukoencephalopathy syndrome. (orig.)

  5. La pesca de sardina, Sardinella aurita (Teleostei: Clupeidae asociada con la variabilidad ambiental del ecosistema de surgencia costera de Nueva Esparta, Venezuela

    Directory of Open Access Journals (Sweden)

    Leo W González

    2007-03-01

    Full Text Available Se comparó la pesca de sardina (Sardinella aurita con algunos parámetros climáticos y meteorológicos del ecosistema de surgencia costera de El Morro, Nueva Esparta, Venezuela. Para el período 1996-2000, se aplicaron los modelos de regresión lineal simple y múltiple a los datos de captura en función de la velocidad del viento, temperatura superficial del mar, temperatura del aire y pluviosidad. Hubo una correlación positiva de la captura con la velocidad del viento, y una negativa con temperatura superficial del mar, temperatura del aire y pluviosidad. El modelo de regresión múltiple con intercepto mostró un ajuste bajo, por tal razón se aplicó un modelo de regresión sin intercepto, el cual mejoró significativamente el ajuste. También se aplicó el método de selección de variables "hacia adelante", encontrándose que las variables independientes viento y temperatura del aire guardan relación significativa con la captura de sardina a tiempo real (pAssociation of sardine fishery, Sardinella aurita (Teleostei: Clupeidae and environmental variability of the coastal upwelling ecosystem of Nueva Esparta, Venezuela. The present research is an analysis of Spanish sardine fishing (Sardinella aurita associated with some climatic and meteorologic parameters of the ecosystem from El Morro Nueva Esparta, Venezuela. The catch and environmental data from the area were taken in the period 1996-2000. Catch data as a function of wind speed, sea surface temperature, air temperature and rain were analyzed by means of simple lineal regression and multiple models. We found a positive correlation of catch with wind speed, and a negative correlation with sea surface temperature, air temperature, and rain. The multiple regression model with intercept had a poor fit, therefore, we made a model without intercept, which improve greatly the fit. A selection of the variables using the forward procedure verified that the independent variables "wind speed

  6. The use of manganese-enhanced magnetic resonance imaging in rat radiation-induced optic neuropathy

    International Nuclear Information System (INIS)

    Guan Xiyin; Wang Jiazhou; Zhou Lijun; Zhu Guopei

    2014-01-01

    Objective: To establish a rat model of radiation-induced optic neuropathy (RION) by delivering a single radiation dose to the optic chiasm. The aim of our study was to analysis the feasibility and effectiveness of manganese-enhanced magnetic resonance imaging (MEMRI) in RION. Methods: 34 Wistar rats were randomized to the control group(4 rats), the 2-month group(5 rats), the 4-month group(4 rats) and the 6-month group(11 rats) according to the different feeding period after irradiation. MEMRI scan were performed when the respective feeding periods of all groups expired. The rats were then killed for histological studies with hematoxylin and eosin stain, Luxol Fast Blue stain, and electron microscopy analysis. Results: The ratio of RION in the four groups were 0/3, 1/5, 2/4 and 11/11, respectively(χ"2 = 15.443, P < 0.05). There was an inverse correlation between the relative optical density value in the LFB stain and the interval between irradiation and pathological examination(R = -0.643, P < 0.05). The number of glial cells in the HE stain in the four groups were 194±65, 234±19, 124±11 and 345±98, respectively(R = 0.590, P < 0.05). When compared MEMRI scan with the corresponding histological examination, we found that there was loss of signals of optic nerve on MEMRI imaging in one of 5 rats in the 2-month group, while no significant histological difference was found between this rat and the others. Conclusions: RION can be non-invasively detected and semi-quantitative analysed by MEMRI scan. Moreover, RION can be early diagnosed by MEMRI scan which is capable to show physiological change in advance of pathological change. (authors)

  7. Investigation of CT and MRI findings of cranio-orbital communicating lesions

    International Nuclear Information System (INIS)

    Wang Zhenchang; Jiang Dingyao; Xian Junfang; An Yuzhi; Zhang Tianming; Li Bin; Liang Xihong; Yang Bentao

    2001-01-01

    Objective: To investigate CT and MRI findings of cranio-orbital communicating lesions so as to find out communicating passages and their imaging features. Methods: Fifty-one cases of cranio-orbital communicating lesions confirmed by pathology and follow-up results were studied. CT was performed in all cases and MRI in 45 cases. Post-contrast CT and MRI was completed in 44 cases. Results: There were 31 cases (60.8%) with lesions communicating between the orbital cavity and the cranial cavity through optic canal or superior orbital fissure showing communicating soft tissue mass and enlargement of optic canal or superior orbital fissure. Four cases of optic gliomas involving optic nerve and optic chiasm, three cases with meningiomas of optic nerve sheath, and 2 cases with retinoblastoma involving optic nerve and optic chiasm showed cranio-orbital communicating masses through the optic canal. Cranio-orbital communicating mass with enlargement of superior orbital fissure was found in 22 patients including 5 meningiomas, 4 neurogenic tumors, 1 dermoid cyst, 3 inflammatory pseudotumors, 2 Tolosa-Hunt syndromes and 7 metastases from nasopharyngeal carcinoma. In addition, 20 of 51 cases (39.2%) communicated through perforating blood vessels or bony defect resulted from tumor destruction. Of these lesions, there were 10 metastases showing bone destruction in orbital walls, 5 cases with en plaque meningiomas of sphenoid bone with marked hyperostosis and widespread dural involvement, 1 chondrosarcoma involving frontal lobe and orbit, 3 adenoid cystic carcinomas involving frontal lobe, and 1 malignant meningioma with bone destruction of the superior orbital wall. Conclusion: CT and MRI could definitely demonstrate communicating passages of cranio-orbital communicating lesions and their imaging changes, which could contribute to diagnosis and differential diagnosis and provide valuable information for determining treatment measures and surgical approach

  8. A role for biological optimization within the current treatment planning paradigm

    International Nuclear Information System (INIS)

    Das, Shiva

    2009-01-01

    reduced (after DVO) by 5.0%/3.9%, and highest doses were reduced by 4.6%/7.8%. The optimization with purely biological OAR objectives achieved bladder/rectal EUDs that were 7.4%/3.1% lower than from DVO, but only reduced highest doses by 1.4%/0.7%. In the olfactory neuroblastoma case, the target was closely surrounded by the eyes, optic nerves, chiasm, and brainstem. In one of the scenarios studied, the eyes, optic nerves, and chiasm were targeted for EUD reduction after DVO. EUD to the left eye, right eye, left optic nerve, right optic nerve, and chiasm were reduced by 7.0%, 5.7%, 4.7%, 4.1%, and 0.6%, respectively, and highest doses were reduced by 16.5%, 11.0%, 5.1%, 3.8%, and 1.5%, respectively. The optimization with purely biological OAR objectives was less effective for the eyes and optics nerves. EUDs for the left eye/right eye/left optic nerve/right optic nerve/chiasm were lower than that from DVO by 0.4%/2.7%/4.0%/2.8%/15.6% and highest doses were lower by 4.6%/1.4%/2.4%/6.4%/7.1% (but purely biological optimization was better overall for the OARs not targeted for EUD reduction). Conclusions: Incorporating biological optimization after dose-volume constrained optimization can further reduce biological metrics, while preserving the important dose reductions achieved by dose-volume constrained optimization. Thus, biological optimization may be accommodated within the framework of current IMRT planning clinical expectations.

  9. Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma

    International Nuclear Information System (INIS)

    Wang Xiaochun; Zhang Xiaodong; Dong Lei; Liu, Helen; Gillin, Michael; Ahamad, Anesa; Ang Kian; Mohan, Radhe

    2005-01-01

    Purpose: To determine the effectiveness of noncoplanar beam configurations and the benefit of plans using fewer but optimally placed beams designed by a parallelized multiple-resolution beam angle optimization (PMBAO) approach. Methods and Materials: The PMBAO approach uses a combination of coplanar and noncoplanar beam configurations for intensity-modulated radiation therapy (IMRT) treatment planning of paranasal sinus cancers. A smaller number of beams (e.g. 3) are first used to explore the solution space to determine the best and worst beam directions. The results of this exploration are then used as a starting point for determining an optimum beam orientation configuration with more beams (e.g. 5). This process is parallelized using a message passing interface, which greatly reduces the overall computation time for routine clinical practice. To test this approach, treatment for 10 patients with paranasal sinus cancer was planned using a total of 5 beams from a pool of 46 possible beam angles. The PMBAO treatment plans were also compared with IMRT plans designed using 9 equally spaced coplanar beams, which is the standard approach in our clinic. Plans with these two different beam configurations were compared with respect to dose conformity, dose heterogeneity, dose-volume histograms, and doses to organs at risk (i.e., eyes, optic nerve, optic chiasm, and brain). Results: The noncoplanar beam configuration was superior in most paranasal sinus carcinoma cases. The target dose homogeneity was better using a PMBAO 5-beam configuration. However, the dose conformity using PMBAO was not improved and was case dependent. Compared with the 9-beam configuration, the PMBAO configuration significantly reduced the mean dose to the eyes and optic nerves and the maximum dose to the contralateral optical path (e.g. the contralateral eye and optic nerve). The maximum dose to the ipsilateral eye and optic nerve was also lower using the PMBAO configuration than using the 9-beam

  10. MR imaging findings in granular cell tumor of the neurohypophysis: a difficult preoperative diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, A.; Arias, M.; Brasa, J. [Unidad de Resonancia Magnetica (MEDTEC), Hospital Xeral-Cies, Vigo (Spain); Paramo, C. [Servicio de Endocrinologia, Hospital Xeral-Cies, Vigo (Spain); Conde, C. [Servicio de Neurocirugia, Hospital Xeral-Cies, Vigo (Spain); Fernandez, R. [Servicio de Anatomia Patologica, Hospital Xeral-Cies, Vigo (Spain)

    2000-12-01

    Granular cell tumor is a rare neoplasm arising within the neurohypophysis. We describe the MR imaging findings in two symptomatic patients. In one patient with history of panhypopituitarism, MR images showed a large sellar and suprasellar mass. The other patient presented with acute loss of vision in her left eye, and MR images showed a suprasellar mass with compression of the optic chiasm. (orig.)

  11. MR imaging findings in granular cell tumor of the neurohypophysis: a difficult preoperative diagnosis

    International Nuclear Information System (INIS)

    Iglesias, A.; Arias, M.; Brasa, J.; Paramo, C.; Conde, C.; Fernandez, R.

    2000-01-01

    Granular cell tumor is a rare neoplasm arising within the neurohypophysis. We describe the MR imaging findings in two symptomatic patients. In one patient with history of panhypopituitarism, MR images showed a large sellar and suprasellar mass. The other patient presented with acute loss of vision in her left eye, and MR images showed a suprasellar mass with compression of the optic chiasm. (orig.)

  12. SU-C-BRA-04: Automated Segmentation of Head-And-Neck CT Images for Radiotherapy Treatment Planning Via Multi-Atlas Machine Learning (MAML)

    International Nuclear Information System (INIS)

    Ren, X; Gao, H; Sharp, G

    2016-01-01

    Purpose: Accurate image segmentation is a crucial step during image guided radiation therapy. This work proposes multi-atlas machine learning (MAML) algorithm for automated segmentation of head-and-neck CT images. Methods: As the first step, the algorithm utilizes normalized mutual information as similarity metric, affine registration combined with multiresolution B-Spline registration, and then fuses together using the label fusion strategy via Plastimatch. As the second step, the following feature selection strategy is proposed to extract five feature components from reference or atlas images: intensity (I), distance map (D), box (B), center of gravity (C) and stable point (S). The box feature B is novel. It describes a relative position from each point to minimum inscribed rectangle of ROI. The center-of-gravity feature C is the 3D Euclidean distance from a sample point to the ROI center of gravity, and then S is the distance of the sample point to the landmarks. Then, we adopt random forest (RF) in Scikit-learn, a Python module integrating a wide range of state-of-the-art machine learning algorithms as classifier. Different feature and atlas strategies are used for different ROIs for improved performance, such as multi-atlas strategy with reference box for brainstem, and single-atlas strategy with reference landmark for optic chiasm. Results: The algorithm was validated on a set of 33 CT images with manual contours using a leave-one-out cross-validation strategy. Dice similarity coefficients between manual contours and automated contours were calculated: the proposed MAML method had an improvement from 0.79 to 0.83 for brainstem and 0.11 to 0.52 for optic chiasm with respect to multi-atlas segmentation method (MA). Conclusion: A MAML method has been proposed for automated segmentation of head-and-neck CT images with improved performance. It provides the comparable result in brainstem and the improved result in optic chiasm compared with MA. Xuhua Ren and Hao

  13. SU-C-BRA-04: Automated Segmentation of Head-And-Neck CT Images for Radiotherapy Treatment Planning Via Multi-Atlas Machine Learning (MAML)

    Energy Technology Data Exchange (ETDEWEB)

    Ren, X; Gao, H [Shanghai Jiao Tong University, Shanghai, Shanghai (China); Sharp, G [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: Accurate image segmentation is a crucial step during image guided radiation therapy. This work proposes multi-atlas machine learning (MAML) algorithm for automated segmentation of head-and-neck CT images. Methods: As the first step, the algorithm utilizes normalized mutual information as similarity metric, affine registration combined with multiresolution B-Spline registration, and then fuses together using the label fusion strategy via Plastimatch. As the second step, the following feature selection strategy is proposed to extract five feature components from reference or atlas images: intensity (I), distance map (D), box (B), center of gravity (C) and stable point (S). The box feature B is novel. It describes a relative position from each point to minimum inscribed rectangle of ROI. The center-of-gravity feature C is the 3D Euclidean distance from a sample point to the ROI center of gravity, and then S is the distance of the sample point to the landmarks. Then, we adopt random forest (RF) in Scikit-learn, a Python module integrating a wide range of state-of-the-art machine learning algorithms as classifier. Different feature and atlas strategies are used for different ROIs for improved performance, such as multi-atlas strategy with reference box for brainstem, and single-atlas strategy with reference landmark for optic chiasm. Results: The algorithm was validated on a set of 33 CT images with manual contours using a leave-one-out cross-validation strategy. Dice similarity coefficients between manual contours and automated contours were calculated: the proposed MAML method had an improvement from 0.79 to 0.83 for brainstem and 0.11 to 0.52 for optic chiasm with respect to multi-atlas segmentation method (MA). Conclusion: A MAML method has been proposed for automated segmentation of head-and-neck CT images with improved performance. It provides the comparable result in brainstem and the improved result in optic chiasm compared with MA. Xuhua Ren and Hao

  14. 706-IJBCS-Article-Rose Danielle Aboua

    African Journals Online (AJOL)

    DR GATSING

    Notopteridae. Papyrocranus afer. Paf. +. +. +. Clupeidae. Pellonula leonensis1. Ple. +. +. +. +. +. Marcusenius furcidens. Mfu. +. Marcusenius senegalensis Mse. +. +. +. +. +. Marcusenius ussheri. Mus. +. +. +. +. +. Marcusenius sp. Msp. +. Mormyrops anguilloides. Man. +. +. +. +. Mormyrus rume. Mru. +. +. +. Pollimyrus isidori.

  15. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  16. Optic neuropathy following combined proton and photon radiotherapy for base of skull tumors

    International Nuclear Information System (INIS)

    Kim, June; Munzenrider, John; Maas, Alicea; Finkelstein, Dianne; Liebsch, Norbert; Hug, Eugen; Suit, Herman; Smith, Al; Goitein, Michael

    1997-01-01

    Purpose/Objective: To evaluate the risk of radiation injury to the optic pathway following high dose radiation therapy (RT) for base of skull tumors with regard to the following variables: diabetes, hypertension, number of surgical procedures, use of patch, patch distance, radiation dose, and volume of optic structures receiving 50, 55, or 60 Cobalt Gray Equivalent (CGE). Materials and Methods: A total of 359 patients with base of skull chordoma or low grade chondrosarcoma received high dose radiation therapy. Patients were treated with external beam radiotherapy utilizing protons alone or combined protons and photons. Protons of 160 MeV were delivered at the Harvard Cyclotron Laboratory using a modulated Bragg peak. The tumor dose ranged from 61 to 76 CGE. CGE was used because modulated protons have an RBE of 1.1 compared to 60 Co. Among 359 patients, 85 patients were excluded from evaluation based on age, tumor location, and pre-RT treatment criteria. All 274 evaluable patients had a minimum follow up of 12 months. Medical records were reviewed to determine the actual cause of vision changes. A total of 12 patients with grade II, III, and IV radiation-induced optic neuropathy were identified. Twenty-four patients without complications who closely matched the aforementioned 12 cases with optic neuropathy were selected from the 274 patients as a control group. Dose volume histograms of 12 cases and 24 controls were reviewed to determine minimum, median, and maximum dose to the optic apparatus as well as dose volume at 50, 55, and 60 CGE. Other information regarding remaining potential risk factors, such as diabetes, hypertension, number of surgical procedures, use of patch, and patch distance, was also obtained. Results: A total of 12 patients (4.4%) developed radiation-induced optic neuropathy: 1 grade II, 9 grade III, and 2 grade IV. Specific sites of involvement were left optic nerve in 9, right optic nerve in 5, and chiasm in 4 cases. The duration to the onset

  17. Childhood optic chiasm gliomas: radiographic response following radiotherapy and long-term clinical outcome

    International Nuclear Information System (INIS)

    Tao, May L.; Barnes, Patrick D.; Billett, Amy L.; Leong, Traci; Shrieve, Dennis C.; Scott, R. Michael; Tarbell, Nancy J.

    1997-01-01

    Purpose: In children with chiasmal gliomas, radiation therapy can arrest progressive visual and neurologic impairment. We examined the radiographic response and clinical outcomes after irradiation. Methods and Materials: Forty-two children (median age at diagnosis, 6.6 years) with chiasmal gliomas were managed as follows: 11 asymptomatic patients with neurofibromatosis-1 (NF-1) were observed only; 2 patients, less than 3 years old, underwent surgery and chemotherapy to delay irradiation; and 29 patients with progressive disease received radiation with or without prior surgery or chemotherapy. Time to radiographic response, long-term tumor control and late sequelae were reviewed for the 29 irradiated patients. Results: The probability of at least 50% radiographic response at 24 months after irradiation was 18.1% and increased to 38.2% by 48 months and 45.9% by 60 months. By actuarial analysis, the median time for such radiographic response was 62 months. For the 29 irradiated patients, the 10-year freedom from progression and overall survival rates were 100% and 89%, respectively (median follow-up for surviving patients, 108 months). Stabilization or improvement in vision occurred in 81% of 26 evaluable irradiated patients. Conclusions: Notable radiographic response may be observed years after irradiation. Radiation therapy provides excellent long-term tumor control and vision preservation or improvement in the majority of patients with progressive chiasmal gliomas

  18. MR and CT diagnosis of carotid pseudoaneurysm in children following surgical resection of craniopharyngioma

    International Nuclear Information System (INIS)

    Lakhanpal, S.K.; Glasier, C.M.; James, C.A.; Angtuaco, E.J.C.

    1995-01-01

    We report the cases of two children who underwent CT, MR, MRA and angiography in the diagnosis of postoperative aneurysmal dilatation of the supraclinoid carotid arteries following surgical resection of craniopharyngioma. Craniopharyngiomas are relatively common lesions, accounting for 6-7 % of brain tumors in children. They are histologically benign, causing symptoms by their growth within the sella and suprasellar cistern with compression of adjacent structures, especially the pituitary gland, hypothalamus and optic nerves, chiasm, and tracts. (orig.)

  19. MR and CT diagnosis of carotid pseudoaneurysm in children following surgical resection of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Lakhanpal, S.K. [Dept. of Radiology, Univ. of Arkansas for Medical Sciences and Arkansas Children`s Hospital, Little Rock, AR (United States); Glasier, C.M. [Dept. of Radiology, Univ. of Arkansas for Medical Sciences and Arkansas Children`s Hospital, Little Rock, AR (United States); James, C.A. [Dept. of Radiology, Univ. of Arkansas for Medical Sciences and Arkansas Children`s Hospital, Little Rock, AR (United States); Angtuaco, E.J.C. [Dept. of Radiology, Univ. of Arkansas for Medical Sciences and Arkansas Children`s Hospital, Little Rock, AR (United States)

    1995-06-01

    We report the cases of two children who underwent CT, MR, MRA and angiography in the diagnosis of postoperative aneurysmal dilatation of the supraclinoid carotid arteries following surgical resection of craniopharyngioma. Craniopharyngiomas are relatively common lesions, accounting for 6-7 % of brain tumors in children. They are histologically benign, causing symptoms by their growth within the sella and suprasellar cistern with compression of adjacent structures, especially the pituitary gland, hypothalamus and optic nerves, chiasm, and tracts. (orig.)

  20. The Effect of Levothyroxine on Serum Levels of Interleukin 10 and Interferon-gamma in Rat Model of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Cobra Payghani

    2017-01-01

    Full Text Available Background: There is an increase in inflammatory and a reduction in anti-inflammatory cytokines in multiple sclerosis (MS. Considering the role of thyroid hormones in the development and regulation of both neural and immune systems, the aim of this study was to evaluate the effects of levothyroxine on serum concentrations of interleukin-10 (IL-10 and interferon gamma (IFN-γ in animal models of MS. Materials and Methods: To induce demyelination in male Wistar rats, lysolecithin was injected into the optic chiasm. Then levothyroxine was injected intraperitoneally (20, 50, and 100 μg/kg for 21 days. Serum levels of cytokines were measured by enzyme-linked immunosorbent assay at 7, 14, and 21 days after that. Results: The results showed that injection of lysolecithin to the optic chiasm only increased serum concentrations of IL-10 compared to the sham group (P < 0.05 at 7th day, but this increase was prevented by all doses of levothyroxine. IFN-γ was decreased significantly (P < 0.001 21 days after. Comparing to the sham group at all sampling time and with respect to the MS group at the days 7 and 21, levothyroxine decreased serum concentrations of IFN-γ significantly. Conclusion: The results showed that thyroid hormones probably could produce protective effects against induced demyelination through affecting immune responses.

  1. Mid-aortic syndrome with renovascular hypertension and multisystem involvement in a girl with familiar neurofibromatosis von Recklinghausen type 1.

    Science.gov (United States)

    Petrak, Borivoj; Bendova, Sarka; Seeman, Tomas; Klein, Tibor; Lisy, Jiri; Zatrapa, Tomas; Marikova, Tana

    2007-12-01

    Neurofibromatosis von Recklinghausen type 1 (NF1) is an autosomal dominant neurocutaneous disorder affecting one in 3 000-4 000 individuals. Mid-aortic syndrome (MAS) is a rare condition characterized by segmental narrowing of abdominal aorta and stenosis of its major branches - mainly renal arteries, including manifestation of renovascular hypertension. MAS can be caused by different diseases, including NF1. A 9 years old girl with primary diagnosis of NF1 combined with renovascular hypertension due to MAS, suffered of bilateral optic and chiasm glioma, pubertas praecox, speech disorder, light mental retardation and scoliosis. We have found a mutation in exone 34 of the NF1 gene (17q11.2). Her father has been also diagnosed with NF1 and hypertension developed at early age. He has the same mutation in exone 34 of NF1 gene. The girl is currently treated with conservative antihypertensive medication with positive effect. Bilateral optic and chiasm glioma are asymptomatic at the time and they had been without progress over period of time. Any vascular surgery, neurosurgical and oncological therapy are not indicated at the present time. This article is a summary of clinical findings in patient with NF1 due to NF1 gene mutation in exone 34. It confirms the importance of complex multidisciplinar approach to examination and taking care of NF1 patients and their families.

  2. Neuroanatomy-based matrix-guided trimming protocol for the rat brain.

    Science.gov (United States)

    Defazio, Rossella; Criado, Ana; Zantedeschi, Valentina; Scanziani, Eugenio

    2015-02-01

    Brain trimming through defined neuroanatomical landmarks is recommended to obtain consistent sections in rat toxicity studies. In this article, we describe a matrix-guided trimming protocol that uses channels to reproduce coronal levels of anatomical landmarks. Both setup phase and validation study were performed on Han Wistar male rats (Crl:WI(Han)), 10-week-old, with bodyweight of 298 ± 29 (SD) g, using a matrix (ASI-Instruments(®), Houston, TX) fitted for brains of rats with 200 to 400 g bodyweight. In the setup phase, we identified eight channels, that is, 6, 8, 10, 12, 14, 16, 19, and 21, matching the recommended landmarks midway to the optic chiasm, frontal pole, optic chiasm, infundibulum, mamillary bodies, midbrain, middle cerebellum, and posterior cerebellum, respectively. In the validation study, we trimmed the immersion-fixed brains of 60 rats using the selected channels to determine how consistently the channels reproduced anatomical landmarks. Percentage of success (i.e., presence of expected targets for each level) ranged from 89 to 100%. Where 100% success was not achieved, it was noted that the shift in brain trimming was toward the caudal pole. In conclusion, we developed and validated a trimming protocol for the rat brain that allow comparable extensiveness, homology, and relevance of coronal sections as the landmark-guided trimming with the advantage of being quickly learned by technicians. © 2014 by The Author(s).

  3. Case of neurosarcoidosis monitored by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T; Kimura, M; Komai, T; Yamamoto, S; Yamamura, I [Kanazawa Univ. (Japan). School of Medicine

    1979-12-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis.

  4. A case of neurosarcoidosis monitored by computerized tomography

    International Nuclear Information System (INIS)

    Kubota, Toshihiko; Kimura, Makoto; Komai, Toshio; Yamamoto, Shinjiro; Yamamura, Itaru

    1979-01-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis. (author)

  5. Hypophysiary hyperplasia secondary to primary hypothyroidism

    International Nuclear Information System (INIS)

    Garcia, Jorge; Polania, Diana Ligia; Builes, Carlos Alfonso

    2005-01-01

    This is a 43 years old woman, complaining of galactorhea, headache and hyperprolactinaemia. A large macro adenoma of the pituitary with extensive suprasellar extension and displacement of the optic chiasm was detected on MRI and primary hypothyroidism was found. After treatment with levothyroxine for four months, her TSH and prolactin levels returned to normal, her symptoms improved and a marked shrinkage of the selar lesion was observed. The visual fields returned to normal. This is a case of pituitary hyperplasia due to primary hypothyroidism

  6. Pre- and postoperative MR imaging of craniopharyngiomas

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Rijkshospitalet, Oslo (Norway). Dept. of Radiology; Eldevik, O.P. [Rijkshospitalet, Oslo (Norway). Dept. of Neurosurgery; Quint, D.J. [Rijkshospitalet, Oslo (Norway). Dept. of Neurosurgery; Chandler, W.F. [Univ. of Michigan Hospital, Ann Arbor, MI (United States). Dept. of Radiology; Kollevold, T. [Univ. of Michigan Hospital, Ann Arbor, MI (United States). Dept. of Neurosurgery

    1996-09-01

    Purpose: To compare the pre- and postoperative MR appearance of craniopharyngiomas with respect to lesion size, tumour morphology and identification of surrounding normal structures. Material and Methods: MR images obtained prior to and following craniopharyngioma resection were evaluated retrospectively in 10 patients. Tumour signal charcteristics, size and extension with particular reference to the optic chiasm, the pituitary gland, the pituitary stalk and the third ventricle were evaluated. Results: Following surgery, tumour volume was reduced in all patients. In 6 patients there was further tumour volume reduction between the first and second postoperative images. Two of these patients received radiation therapy between the 2 postoperative studies, while 4 had no adjuvant treatment to the surgical intervention. There was improved visualization of the optic chiasm, in 3, the pituitary stalk in one, and the third ventricle in 9 of the 10 patients. The pituitary gland was identified preoperatively only in one patient, postoperatively only in another, pre- and postoperatively in 5, and neither pre- nor postoperatively in 3 patients. In 3 patients MR imaging 0-7 days postoperatively identified tumour remnants not seen at the end of the surgical procedure. The signal intensities of solid and cystic tumour components were stable from pre- to the first postoperative MR images. Optic tract increased signal prior to surgery was gone 28 days postoperatively in one patient, but persisted on the left side for 197 days after surgery in another. Conclusion: Postoperative MR imaging of craniopharyngiomas demonstrated tumour volume reduction and tumour remnants not seen at surgery. Early postoperative MR imaging of craniopharyngiomas may overestimate the size of residual tumour. Improved visualization of peritumoral structures may be achieved. (orig.).

  7. Expanded Endoscopic Endonasal Resection of Retrochiasmatic Craniopharyngioma.

    Science.gov (United States)

    Davanzo, Justin R; Goyal, Neerav; Zacharia, Brad E

    2018-02-01

    This video abstract demonstrates the use of the expanded endoscopic endonasal approach for the resection of a retrochiasmatic craniopharyngioma. These tumors are notoriously difficult to treat, and many approaches have been tried to facilitate safe and effective resection. The endoscopic endonasal approach has been increasingly utilized for selected sellar/suprasellar pathology. We present the case of a 39-year-old man who was found to have a cystic, partially calcified suprasellar mass consistent with a craniopharyngioma. To facilitate robust skull base repair, a vascularized nasoseptal flap was harvested. A wide sphenoidotomy was performed and the sella and tuberculum were exposed. After the dural opening and arachnoid dissection, the stalk was identified, merging seamlessly with the tumor capsule. The lesion was then internally debulked with the use of an ultrasonic aspirator. The capsule was then dissected off of the optic chiasm, thalamus, and hypothalamus. The cavity was inspected with an angled endoscope to ensure complete resection. A multilayered reconstruction was performed using autologous fascia lata, the previously harvested nasoseptal flap, and dural sealant. Postoperatively, the patient did have expected panhypopituitarism but remained neurologically intact and had improvement in his vision. In conclusion, this video demonstrates how an expanded endonasal approach can be used to safely resect a craniopharyngioma, even when in close proximity to delicate structures such as the optic chiasm. The link to the video can be found at: https://youtu.be/tahjHmrXhc4 .

  8. Diagnosis and management of prolactinomas

    International Nuclear Information System (INIS)

    Blackwell, R.E.

    1985-01-01

    A summary is presented of the contemporary view of the diagnosis and treatment of pituitary prolactinomas. The use of radiotherapy is discussed in detail. Radiation sources include radiocobalt teletherapy and 4-MEV linear accelerators. Complications following radiotherapy include epilation, optic nerve and chiasm injury, brain necrosis, and sarcoma formation. Additionally there is loss of trophic hormone secretion. In addition to conventional radiotherapy techniques, Bragg peak proton hypophysectomy has been used successfully and appears to have the lowest mortality rate. CAT scans are used for diagnosis and follow-up. 93 references, 8 figures

  9. Suprasellar ganglioglioma with unusual diffuse involvement of the entire optico-chiasmal hypothalamic pathway

    Directory of Open Access Journals (Sweden)

    Jalali Rakesh

    2008-01-01

    Full Text Available Gangliogliomas (GG are mixed glioneuronal tumors of the central nervous system (CNS, occurring mostly in the pediatric population, with common sites being temporal lobes and less commonly in the frontal and parietal lobes. We report a case of a 7-year-old child who presented with bilateral visual defects for 6 months. Magnetic resonance imaging (MRI of the brain revealed an intensely enhancing mass lesion with calcification in the sellar and suprasellar region involving the optic chiasm and the left optic nerve. The mass showed almost bilaterally symmetrical diffuse spread along the optic tracts posteriorly and hypothalamus, temporal lobes, thalami and the basal ganglia. The lesion was radiologically indistinguishable from chiasmatic astrocytoma or a germ cell tumor but histopathological features were of a ganglioglioma. While a few optic apparatus gangliogliomas have been reported in the literature, such widespread diffuse involvement of the entire optico-chiasmal hypothalamic pathway is unusual.

  10. Exchange transfusion with fluorocarbon for studying synaptically evoked optical signal in rat cortex.

    Science.gov (United States)

    Nomura, Y; Fujii, F; Sato, C; Nemoto, M; Tamura, M

    2000-02-01

    . Zieglgansberger, The intrinsic optical signal evoked by chiasm stimulation in the rat suprachiasmatic nuclei exhibits GABAergic day-night variation, Eur. J. Neurosci. 8 (1996) 319-328] [3] [9] [13] [24]. A spectral fitting method with three components is used for the analysis of intrinsic optical signal [M. Nemoto, Y. Nomura, C. Sato, M. Tamura, K. Houkin, I. Koyanagi, H. Abe, Analysis of optical signals evoked by peripheral nerve stimulation in rat somatosensory cortex: dynamic changes in hemoglobin concentration and oxygenation, J. Cereb. Blood Flow Metab. 19 (1999) 246-259] [17]. In order to validate the analysis, we need the knowledge on contribution of signal resulted from hemoglobin to total intrinsic optical signal. The exchange transfusion with fluorocarbon has the advantage that can change the spectral contribution of hemoglobin [M. Ferrari, M.A. Williams, D.A. Wilson, N.V. Thakor, R.J. Traystman, D.F. Hanley, Cat brain cytochrome-c oxidase redox changes induced by hypoxia after blood-fluorocarbon exchange transfusion, Am. J. Physiol. 269 (1995) H417-H424; A.L. Sylvia, C.A. Piantadosi, O(2) dependence of in vivo brain cytochrome redox responses and energy metabolism in bloodless rats, J. Cereb. Blood Flow Metab. 8 (1988) 163-172] [6] [23]. Here we describe a new method of the reduction of hemoglobin signal from somatosensory evoked optical intrinsic signal in rat cortex by the combination of exchange transfusion with fluorocarbon and imaging system of thinned skull cranial window. The method allows for the study of the synaptically evoked changes in light scattering as well as fluorescence of calcium indicator or voltage-sensitive dye without absorption of hemoglobin.

  11. [Microsurgical anatomy importance of A1-anterior communicating artery complex].

    Science.gov (United States)

    Monroy-Sosa, Alejandro; Pérez-Cruz, Julio César; Reyes-Soto, Gervith; Delgado-Hernández, Carlos; Macías-Duvignau, Mario Alberto; Delgado-Reyes, Luis

    2013-01-01

    The anterior cerebral artery originates from the bifurcation of the internal carotid artery lateral to the optic chiasm, then joins with its contralateral counterpart via the anterior communicating artery. A1-anterior communicating artery complex is the most frequent anatomical variants and is the major site of aneurysms between 30 to 37%. Know the anatomy microsurgical, variants anatomical and importance of complex precommunicating segment-artery anterior communicating in surgery neurological of the pathology vascular, mainly aneurysms, in Mexican population. The study was performed in 30 brains injected. Microanatomy was studied (length and diameter) of A1-anterior communicating artery complex and its variants. 60 segments A1, the average length of left side was 11.35 mm and 11.84 mm was right. The average diameter of left was 1.67 mm and the right was 1.64 mm. The average number of perforators on the left side was 7.9 and the right side was 7.5. Anterior communicating artery was found in 29 brains of the optic chiasm, its course depended on the length of the A1 segment. The average length of the segment was 2.84 mm, the average diameter was 1.41 mm and the average number of perforators was 3.27. A1-anterior communicating artery complex variants were found in 18 (60%) and the presence of two blister-like aneurysms. It is necessary to understand the A1-anterior communicating artery complex microanatomy of its variants to have a three-dimensional vision during aneurysm surgery.

  12. An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways

    International Nuclear Information System (INIS)

    Claus, Filip; Gersem, Werner de; Wagter, Carlos de; Severen, Robert van; Vanhoutte, Ilse; Duthoy, Wim; Remouchamps, Vincent; Duyse, Bart van.; Vakaet, Luc; Lemmerling, Marc; Vermeersch, Hubert; Neve, Wilfried de

    2001-01-01

    Purpose: To develop a protocol for the irradiation of ethmoid sinus cancer, with the aim of sparing binocular vision; of developing a strategy of intensity-modulated radiation therapy (IMRT) planning that produces dose distributions that (1) are consistent with the protocol prescriptions and (2) are deliverable by static segmental IMRT techniques within a 15-minute time slot; of fine tuning the implementation strategy to a class solution approach that is sufficiently automated and efficient, allowing routine clinical application; of reporting on the early clinical implementation involving 11 patients between February 1999 and July 2000. Patients and Methods: Eleven consecutive T1-4N0M0 ethmoid sinus cancer patients were enrolled in the study. For Patients 1-8, a first protocol was implemented, defining a planning target volume prescription dose of 60 to 66 Gy in 30-33 fractions and a maximum dose (Dmax) of 50 Gy to optic pathway structures and spinal cord and limit of 60 Gy to brainstem. For Patients 9-11, an adapted (now considered mature) protocol was implemented, defining a (planning target volume) prescription dose of 70 Gy in 35 fractions and a Dmax to optic pathway structures and brainstem of 60 Gy and to spinal cord of 50 Gy. Results: The class solution-directed strategy developed during this study reduced the protocol translation process from a few days to about 2 hours of planner time. The mature class solution involved the use of 7 beam incidences (20-37 segments), which could be delivered within a 15-minute time slot. Acute side effects were limited and mild. None of the patients developed dry eye syndrome or other visual disturbances. The follow-up period is too short for detection of retinopathy or optic nerve and chiasm toxicity. Conclusion: Conventional radiotherapy of ethmoid sinus tumors is associated with serious morbidity, including blindness. We hypothesize that IMRT has the potential to save binocular vision. The dose to the optic pathway

  13. Age-Related Vitamin D Deficiency Is Associated with Reduced Macular Ganglion Cell Complex: A Cross-Sectional High-Definition Optical Coherence Tomography Study.

    Directory of Open Access Journals (Sweden)

    Mathieu Uro

    Full Text Available Vitamin D deficiency is associated with smaller volume of optic chiasm in older adults, indicating a possible loss of the visual axons and their cellular bodies. Our objective was to determine whether vitamin D deficiency in older adults is associated with reduced thickness of the ganglion cell complex (GCC and of the retinal nerve fibre layer (RNFL, as measured with high-definition optical coherence tomography (HD-OCT.Eighty-five French older community-dwellers without open-angle glaucoma and patent age-related macular degeneration (mean, 71.1±4.7 years; 45.9% female from the GAIT study were separated into 2 groups according to serum 25OHD level (i.e., deficient≤25 nmol/L or sufficient>25 nmol/L. Measurements of GCC and RNFL thickness were performed using HD-OCT. Age, gender, body mass index, number of comorbidities, dementia, functional autonomy, intracranial volume, visual acuity, serum calcium concentration and season of testing were considered as potential confounders.Mean serum 25OHD concentration was 58.4±26.8 nmol/L. Mean logMAR visual acuity was 0.03±0.06. Mean visual field mean deviation was -1.25±2.29 dB. Patients with vitamin D deficiency (n=11 had a reduced mean GCC thickness compared to those without vitamin D deficiency (72.1±7.4 μm versus 77.5±7.5 μm, P=0.028. There was no difference of the mean RNFL thickness in these two groups (P=0.133. After adjustment for potential confounders, vitamin D deficiency was associated with reduced GCC thickness (ß=-5.12, P=0.048 but not RNFL thickness (ß=-9.98, P=0.061. Specifically, vitamin D deficiency correlated with the superior medial GCC area (P=0.017 and superior temporal GCC area (P=0.010.Vitamin D deficiency in older patients is associated with reduced mean GCC thickness, which can represent an early stage of optic nerve damage, prior to RNFL loss.

  14. Expanded Endoscopic Transnasal Approach to the Chordoid Glioma of the Third Ventricle : The First Case Ever Reported.

    Science.gov (United States)

    Zeinalizadeh, Mehdi; Sadrehosseini, Seyed Mousa; Tayebi Meybodi, Keyvan; Sharifabadi, Ali Heidari

    2016-11-01

    Chordoid glioma of the third ventricle is a rare and challenging tumor to surgery because of its unique anatomical location and its close juxtaposition to the neurovascular structures and hypothalamus. The authors report a case of chordoid glioma of the third ventricle in a 43-year-old woman, who presented with headache and somnolence. The tumor was approached by endoscopic transnasal technique with a favorable result. Histopathologic examination disclosed a neoplastic tissue composed of eosinophilic epithelioid cells, mucinous, periodic acid Schiff-diastase positive, extracellular matrix, and scattered lymphoplasmacytic infiltrates. The best treatment option remains controversial. Customarily, the surgical route to remove chordoid glioma is transcranial; however, the undersurface of the optic chiasm and optic nerves preclude an adequate surgical visualization. In contrast, an expanded endoscopic transnasal approach provides a direct midline corridor to this region without any brain retraction.

  15. MRI of Wolfram syndrome (DIDMOAD)

    Energy Technology Data Exchange (ETDEWEB)

    Galluzzi, P.; Filosomi, G.; Vallone, I.M.; Venturi, C. [Dept. of Neuroradiology, Policlinico ' ' Le Scotte' ' , Siena (Italy); Bardelli, A.M. [Dept. of Ophthalmological Sciences, Unit of Paediatric Ophthalmology, University of Siena (Italy)

    1999-10-01

    Wolfram syndrome (DIDMOAD) is a rare diffuse neurodegenerative disorder characterised by diabetes insipidus, diabetes mellitus, optic atrophy, deafness, and a wide variety of abnormalities of the central nervous system, urinary tract and endocrine glands. It may be familial or sporadic. Reported features on MRI of the brain are absence of the physiological high signal of the posterior lobe of the pituitary, shrinkage of optic nerves, chiasm and tracts, atrophy of the hypothalamic region, brain stem, cerebellum, and cerebral cortex. We report a 12-year-old girl with a 5-year history without brain stem, cerebellar or cerebral atrophy. MRI showed an unusual feature: a focus of high signal on PD- and T2-weighted images in the right substantia nigra. This is consistent with previously reported neuropathological post-mortem studies, but has never been reported in vivo. (orig.)

  16. MRI of Wolfram syndrome (DIDMOAD)

    International Nuclear Information System (INIS)

    Galluzzi, P.; Filosomi, G.; Vallone, I.M.; Venturi, C.; Bardelli, A.M.

    1999-01-01

    Wolfram syndrome (DIDMOAD) is a rare diffuse neurodegenerative disorder characterised by diabetes insipidus, diabetes mellitus, optic atrophy, deafness, and a wide variety of abnormalities of the central nervous system, urinary tract and endocrine glands. It may be familial or sporadic. Reported features on MRI of the brain are absence of the physiological high signal of the posterior lobe of the pituitary, shrinkage of optic nerves, chiasm and tracts, atrophy of the hypothalamic region, brain stem, cerebellum, and cerebral cortex. We report a 12-year-old girl with a 5-year history without brain stem, cerebellar or cerebral atrophy. MRI showed an unusual feature: a focus of high signal on PD- and T2-weighted images in the right substantia nigra. This is consistent with previously reported neuropathological post-mortem studies, but has never been reported in vivo. (orig.)

  17. The Role of Optical Coherence Tomography in an Atypical Case of Oculocutaneous Albinism: A Case Report

    Directory of Open Access Journals (Sweden)

    Settimio Rossi

    2012-03-01

    Full Text Available Background: Oculocutaneous albinism is a group of autosomal recessive disorders featuring hypopigmentation of the hair, skin and eyes. Ocular signs associated with the disease are nystagmus, decreased visual acuity, hypopigmentation of the retina, foveal hypoplasia, translucency of the iris, macular transparency, photophobia and abnormal decussation of nerve fibers at the chiasm. Case Report: An 8-year-old Caucasian girl presented to our clinic ‘Referral Center for Hereditary Retinopathies’ of the Second University of Naples with a diagnosis of Stargardt disease and a progressive reduction in visual acuity in both eyes. She underwent a complete ophthalmic examination including standard electroretinography and optical coherence tomography (OCT. A molecular analysis was also performed. Best-corrected visual acuity was 20/30 in the right eye and 20/40 in the left eye. Biomicroscopy of the anterior segment revealed a transparent cornea, in situ and transparent lens and normally pigmented iris. A mild diffuse depigmentation and macular dystrophy were observed at fundus examination. Standard electroretinography showed normal scotopic and photopic responses. OCT revealed high reflectivity across the fovea without depression. The typical OCT pattern led us to direct the molecular analysis towards the genes involved in oculocutaneous albinism. The molecular analysis identified mutations in the TYR gene. Conclusion: In this case, the role of OCT was crucial in guiding the molecular analysis for the diagnosis of albinism. OCT is therefore instrumental in similar cases that do not present typical characteristics of a disease. The case also proves the relevance of molecular analysis to confirm clinical diagnoses in hereditary retinal diseases.

  18. Influence of habitat structure and environmental variables on larval fish assemblage in the Johor Strait, Malaysia.

    Science.gov (United States)

    Ara, Roushon; Arshad, Aziz; Amin, S M Nurul; Idris, M H; Gaffar, Mazlan Abd; Romano, Nicholas

    2016-07-01

    Our previous study demonstrated that among different habitat sites (mangrove, estuary, river, seagrass and Open Sea) in Johor Strait, Malaysia, seagrass showed highest family diversity and abundance of larval fish. However, it is unclear whether this was due to difference in habitat complexity or water quality parameters.? To test this, larval fish were collected by using a bongo net equipped with a flow meter by subsurface horizontal towing from different habitats in Johor Strait between October 2007 and September 2008.? Various physico-chemical parameters were measured and then examined for any relationship to fish larvae diversity and abundance. Among the 24 families identified from the sites, seven families (Blenniidae, Clupeidae, Mullidae, Nemipteridae, Syngnathidae, Terapontidae and Uranoscopeidae) were significantly correlated with the tested waters quality parameters.? Salinity showed a positive and negative significant correlation with Clupeidae (p Johor Strait, Malaysia. This likely indicates that habitat structure was more important in determining larval abundance (highest in the seagrass habitat) as compared to water quality at the tested sites. This study emphasizes the need to conserve seagrass beds as important nursery grounds for various fish larvae to ensure adequate recruitment and ultimately sustainable fisheries management. ?

  19. Lymphocytic hypophysitis: occurrence in two men.

    Science.gov (United States)

    Lee, J H; Laws, E R; Guthrie, B L; Dina, T S; Nochomovitz, L E

    1994-01-01

    Two men undergoing transsphenoidal exploration for pituitary adenoma were found to have lymphocytic hypophysitis. Both presented with frontal headaches, lethargy, and diminished libido. Laboratory investigations showed markedly depressed serum testosterone, and magnetic resonance imaging demonstrated pituitary enlargement, with optic chiasm involvement. Intraoperatively, the dura was adherent to the pituitary in each case. The resected glands were effaced by a dense lymphoplasmacytic infiltrate and fibrosis, without granulomas. Nonspecific peripheral enhancement on imaging suggested a diagnosis other than adenoma, but more experience with peripheral enhancement in lymphocytic hypophysitis is needed. The diagnosis was histological and required surgical intervention. Long-term pituitary replacement therapy is usually required.

  20. Ectopic pituitary null cell adenoma arising from the infundibulum in the third ventricle: A successful endonasal transsphenoidal resection after long-term follow-up MR imaging – A technical note

    Directory of Open Access Journals (Sweden)

    Yuichiro Yoneoka, M.D., Ph.D.

    2017-12-01

    Conclusion: To our best knowledge, this is the first case with long-term preoperative follow-up images, which can bridge the knowledge gap in operations of third ventricle ectPA as following: (1 Truly third ventricle ectPA can exist, (2 the third ventricle ectPA extended into the sella turcica along the pituitary stalk, (3 this ectPA can arise from the suprasellar peri-infundibular ectopic pituitary cells or the pars tuberalis of the adenohypophysis, and therefore adhere to the optic chiasm, (4 thus neurosurgeons should take great care in resection of ectPA arising from the infundibulum, and (5 it can be resected through an endoscopic extended transsphenoidal approach.

  1. Fractionated radiosurgery for 9L gliosarcoma in the rat brain

    International Nuclear Information System (INIS)

    Kim, Jae Ho; Khil, Mark S.; Kolozsvary, Andrew; Gutierrez, Jorge A.; Brown, Stephen L.

    1999-01-01

    Purpose: Fractionated radiosurgery is being carried out in the clinic to improve the therapeutic ratio of single-dose radiosurgery using various fractionation schemes. Because there is a paucity of experimental radiobiological data in the literature on the tumor response and late-responding normal tissue of critical intracranial structures to radiosurgery, the present animal study was designed to compare the response following a single high dose of radiation with that obtained from calculated fractionated doses of radiosurgery. Methods and Materials: Male Fischer rats with 9L gliosarcoma growing in their brains were stereotactically irradiated and assayed for the tumor control rate and brain tissue damage. The radiation dose needed for 50% tumor control (TCD 50 ) was used as the endpoint of the efficacy of radiosurgery. Normal brain damage was measured histologically following a period of time over 270 days. Histological evaluation included hematoxylin-eosin (H and E), Luxol fast blue and periodic acid Schiff (LFB/PAS) for the presence of myelin and glial fibrillary acidic protein (GFAP) for the assessment of astrocytic re-activity. The optical density of optic nerves and chiasms staining with LFB/PAS was quantitatively measured using a computer image analysis to assess the magnitude of demyelination. Results: Radiosurgery (RS) was found to be more effective in curing small tumors than large tumors. The dose required to control 50% of the tumored animals for 120 days was 24, 31, and 40 Gy for 2-, 6-, and 12-day-old tumors, respectively. Using 12-day-old brain tumors, two fractions of 23.5 Gy and three fractions of 18.5 Gy were found to be equivalent to the single dose of 35 Gy for tumor control. For normal brain damages, the visual pathways including optic nerves and chiasm were found to be highly radiosensitive structures. A single dose of 35 Gy produced 100% severe optic neuropathy. The fractionated RS regimens spared substantial optic nerve damage. Conclusion

  2. SU-E-T-304: Dosimetric Comparison of Cavernous Sinus Tumors: Heterogeneity Corrected Pencil Beam (PB-Hete) Vs. X-Ray Voxel Monte Carlo (XVMC) Algorithms for Stereotactic Radiotherapy (SRT)

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, D; Sood, S; Badkul, R; Jiang, H; Saleh, H; Wang, F [University of Kansas Hospital, Kansas City, KS (United States)

    2015-06-15

    Purpose: To compare dose distributions calculated using PB-hete vs. XVMC algorithms for SRT treatments of cavernous sinus tumors. Methods: Using PB-hete SRT, five patients with cavernous sinus tumors received the prescription dose of 25 Gy in 5 fractions for planning target volume PTV(V100%)=95%. Gross tumor volume (GTV) and organs at risk (OARs) were delineated on T1/T2 MRI-CT-fused images. PTV (range 2.1–84.3cc, mean=21.7cc) was generated using a 5mm uniform-margin around GTV. PB-hete SRT plans included a combination of non-coplanar conformal arcs/static beams delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000 MU/min) beam. Plans were re-optimized using XVMC algorithm with identical beam geometry and MLC positions. Comparison of plan specific PTV(V99%), maximal, mean, isocenter doses, and total monitor units(MUs) were evaluated. Maximal dose to OARs such as brainstem, optic-pathway, spinal cord, and lenses as well as normal tissue volume receiving 12Gy(V12) were compared between two algorithms. All analysis was performed using two-tailed paired t-tests of an upper-bound p-value of <0.05. Results: Using either algorithm, no dosimetrically significant differences in PTV coverage (PTVV99%,maximal, mean, isocenter doses) and total number of MUs were observed (all p-values >0.05, mean ratios within 2%). However, maximal doses to optic-chiasm and nerves were significantly under-predicted using PB-hete (p=0.04). Maximal brainstem, spinal cord, lens dose and V12 were all comparable between two algorithms, with exception of one patient with the largest PTV who exhibited 11% higher V12 with XVMC. Conclusion: Unlike lung tumors, XVMC and PB-hete treatment plans provided similar PTV coverage for cavernous sinus tumors. Majority of OARs doses were comparable between two algorithms, except for small structures such as optic chiasm/nerves which could potentially receive higher doses when using XVMC algorithm. Special attention may need to be paid on a case

  3. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  4. Outcome of T4 (International Union Against Cancer Staging System, 7th edition) or Recurrent Nasal Cavity and Paranasal Sinus Carcinoma Treated With Proton Beam

    Energy Technology Data Exchange (ETDEWEB)

    Fukumitsu, Nobuyoshi, E-mail: fukumitsun@yahoo.co.jp [Proton Medical Research Center, University of Tsukuba, Tsukuba (Japan); Okumura, Toshiyuki; Mizumoto, Masashi; Oshiro, Yoshiko; Hashimoto, Takayuki; Kanemoto, Ayae; Hashii, Haruko; Ohkawa, Ayako; Moritake, Takashi; Tsuboi, Koji [Proton Medical Research Center, University of Tsukuba, Tsukuba (Japan); Tabuchi, Keiji; Wada, Tetsuro; Hara, Akira [Department of Otolaryngology, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Tsukuba (Japan); Sakurai, Hideyuki [Proton Medical Research Center, University of Tsukuba, Tsukuba (Japan)

    2012-06-01

    Purpose: To investigate the clinical features, prognostic factors, and toxicity of treatment for unresectable carcinomas of the nasal cavity and paranasal sinus (NCPS) treated with proton beam therapy (PBT). Methods and Materials: Seventeen patients (13 men, 4 women) with unresectable carcinomas of the NCPS who underwent PBT at University of Tsukuba between 2001 and 2007 were analyzed. The patients' median age was 62 years (range, 30-83 years). The tumors were located in the nasal cavity in 3 patients, the frontal sinus in 1, the ethmoid sinus in 9, and the maxillary sinus in 4. The clinical stage was Stage IVA in 5 cases, IVB in 10, and recurrent in 2. The tumors were deemed unresectable for medical reasons in 16 patients and because of refusal at a previous hospital 4 months earlier in 1 patient. All the patients received PBT irradiation dose of 22-82.5 GyE and a total of 72.4-89.6 GyE over 30-64 fractions (median 78 GyE over 36 fractions) with X-ray, with attention not exceeding the delivery of 50 GyE to the optic chiasm and brainstem. Results: The overall survival rate was 47.1% at 2 years and 15.7% at 5 years, and the local control rate was 35.0% at 2 years and 17.5% at 5 years. Invasion of the frontal or sphenoid sinus was a prognostic factor for overall survival or local control. Late toxicity of more than Grade 3 was found in 2 patients (brain necrosis in 1 and ipsilateral blindness in 1); however, no mortal adverse effects were observed. Conclusion: Proton beam therapy enabled a reduced irradiation dose to the optic chiasm and brainstem, enabling the safe treatment of unresectable carcinomas in the NCPS. Superior or posterior extension of the tumor influenced patient outcome.

  5. Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study

    International Nuclear Information System (INIS)

    Deeley, M A; Cmelak, A J; Malcolm, A W; Moretti, L; Jaboin, J; Niermann, K; Yang, Eddy S; Yu, David S; Ding, G X; Chen, A; Datteri, R; Noble, J H; Dawant, B M; Donnelly, E F; Yei, F; Koyama, T

    2011-01-01

    The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.

  6. Outcome of T4 (International Union Against Cancer Staging System, 7th edition) or Recurrent Nasal Cavity and Paranasal Sinus Carcinoma Treated With Proton Beam

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Okumura, Toshiyuki; Mizumoto, Masashi; Oshiro, Yoshiko; Hashimoto, Takayuki; Kanemoto, Ayae; Hashii, Haruko; Ohkawa, Ayako; Moritake, Takashi; Tsuboi, Koji; Tabuchi, Keiji; Wada, Tetsuro; Hara, Akira; Sakurai, Hideyuki

    2012-01-01

    Purpose: To investigate the clinical features, prognostic factors, and toxicity of treatment for unresectable carcinomas of the nasal cavity and paranasal sinus (NCPS) treated with proton beam therapy (PBT). Methods and Materials: Seventeen patients (13 men, 4 women) with unresectable carcinomas of the NCPS who underwent PBT at University of Tsukuba between 2001 and 2007 were analyzed. The patients' median age was 62 years (range, 30–83 years). The tumors were located in the nasal cavity in 3 patients, the frontal sinus in 1, the ethmoid sinus in 9, and the maxillary sinus in 4. The clinical stage was Stage IVA in 5 cases, IVB in 10, and recurrent in 2. The tumors were deemed unresectable for medical reasons in 16 patients and because of refusal at a previous hospital 4 months earlier in 1 patient. All the patients received PBT irradiation dose of 22–82.5 GyE and a total of 72.4–89.6 GyE over 30–64 fractions (median 78 GyE over 36 fractions) with X-ray, with attention not exceeding the delivery of 50 GyE to the optic chiasm and brainstem. Results: The overall survival rate was 47.1% at 2 years and 15.7% at 5 years, and the local control rate was 35.0% at 2 years and 17.5% at 5 years. Invasion of the frontal or sphenoid sinus was a prognostic factor for overall survival or local control. Late toxicity of more than Grade 3 was found in 2 patients (brain necrosis in 1 and ipsilateral blindness in 1); however, no mortal adverse effects were observed. Conclusion: Proton beam therapy enabled a reduced irradiation dose to the optic chiasm and brainstem, enabling the safe treatment of unresectable carcinomas in the NCPS. Superior or posterior extension of the tumor influenced patient outcome.

  7. Hemifield columns co-opt ocular dominance column structure in human achiasma.

    Science.gov (United States)

    Olman, Cheryl A; Bao, Pinglei; Engel, Stephen A; Grant, Andrea N; Purington, Chris; Qiu, Cheng; Schallmo, Michael-Paul; Tjan, Bosco S

    2018-01-01

    In the absence of an optic chiasm, visual input to the right eye is represented in primary visual cortex (V1) in the right hemisphere, while visual input to the left eye activates V1 in the left hemisphere. Retinotopic mapping In V1 reveals that in each hemisphere left and right visual hemifield representations are overlaid (Hoffmann et al., 2012). To explain how overlapping hemifield representations in V1 do not impair vision, we tested the hypothesis that visual projections from nasal and temporal retina create interdigitated left and right visual hemifield representations in V1, similar to the ocular dominance columns observed in neurotypical subjects (Victor et al., 2000). We used high-resolution fMRI at 7T to measure the spatial distribution of responses to left- and right-hemifield stimulation in one achiasmic subject. T 2 -weighted 2D Spin Echo images were acquired at 0.8mm isotropic resolution. The left eye was occluded. To the right eye, a presentation of flickering checkerboards alternated between the left and right visual fields in a blocked stimulus design. The participant performed a demanding orientation-discrimination task at fixation. A general linear model was used to estimate the preference of voxels in V1 to left- and right-hemifield stimulation. The spatial distribution of voxels with significant preference for each hemifield showed interdigitated clusters which densely packed V1 in the right hemisphere. The spatial distribution of hemifield-preference voxels in the achiasmic subject was stable between two days of testing and comparable in scale to that of human ocular dominance columns. These results are the first in vivo evidence showing that visual hemifield representations interdigitate in achiasmic V1 following a similar developmental course to that of ocular dominance columns in V1 with intact optic chiasm. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Roentgenographic features of neurofibromatosis von Recklinghausen

    Energy Technology Data Exchange (ETDEWEB)

    Galanski, M.; Vogelsang, H.; Cramer, B.M.; Thun, F.; Peters, P.E.

    1983-10-01

    The basic abnormality of neurofibromatosis consists not only of a maldevelopment of the neuroectoderm but also of the mesoderm. Therefore any organ or system of the body may be involved. Following a short clinical review of the central (acoustic) and peripheral type the well known and the more unusual radiographic findings are summarized. They include cranial and intracranial manifestations (orbitosphenoid dysplasia, bone defects of the skull, acoustic neuroma, glioma of the optic nerve and chiasm, meningioma), spinal lesions (scoliosis, vetebral scalloping, meningocele, neuroma, ependymoma), skeletal abnormalities (pseudarthrosis), cardiovascular manifestations, pulmonary fibrosis, tumors of the gastrointestinal and urinary tract and different endocrinopathies. Some of the roentgeologic symptoms are very characteristic and allow definitive diagnosis.

  9. Planum sphenoidale meningioma leading to visual disturbance.

    Science.gov (United States)

    Lutwak, Nancy; Dill, Curt; Wieczorek, Rosemary

    2011-08-31

    A 60-year-old male presented with complaints of dizziness, which worsened with fatigue and a sense his balance was 'off'. Initial physical examination was negative and the laboratory testing was unremarkable. Within weeks, the patient developed bilateral visual field deficits. MRI revealed an extra-axial mass which extended into the pituitary fossa and caused compression of the pituitary gland. The pituitary stalk was displaced posteriorly and the optic chiasm was compressed with displacement superiorly and posteriorly. The patient underwent a surgical resection. Diabetes insipidus developed postoperatively requiring a vasopressin drip. He also developed hypopituitarism after the resection with hypothyroidism, hypoadrenalism and hypogonadism. The patient requires testosterone, levothyroxine and hydrocortisone replacement and has mild residual bitemporal hemianopsia.

  10. A rare presentation of craniopharyngioma: delayed puberty

    Science.gov (United States)

    İnci, Mehmet Fatih; Özkan, Fuat; Bozkurt, Selim; Demir, Caner Feyzi

    2012-01-01

    Craniopharyngiomas are the most frequently encountered suprasellar tumours in children. Owing to the slow growth rate of these tumours, they are often quite large before becoming symptomatic. They are more common among children and older adults (55–74 years). Depending upon the direction of growth and tumour size, craniopharyngiomas can affect the hypothalamus, pituitary stalk, optic nerves and chiasm and carotid arteries. Compression of these neural and vascular structures frequently precipitates endocrine disorders, visual loss and an increased intracranial pressure. Hypopituitarism leading to a delayed puberty is a rare presentation of craniopharyngioma. The diagnosis of craniopharyngioma is usually made with the classic radiological imaging features based on CT and MRI. PMID:23195827

  11. MR imaging of the brain in neurofibromatosis

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Cohen, M.L.; Duffner, P.K.; Seidel, F.; Harwood-Nash, D.

    1986-01-01

    Fifteen children and young adults with neurofibromatosis underwent CT and MR imaging (0.5-T superconducting magnet). Seven had optic gliomas and five had other intracranial neoplasms. Before thin-section MR imaging became available, CT was superior for demonstrating the optic nerves, although MR imaging better delineated tumor spread to the optic chiasm and tract. MR imaging was superior for demonstrating other gliomatous lesions associated with neurofibromatosis. Most lesions had long T1 and T2 values and were best seen on T2-weighted images. MR imaging revealed small areas of increased signal intensity on T2-weighted images in nearly half the patients. These lesions were not apparent on CT and were usually located in the globus pallidus, but were seen in many areas of the brain, commonly in the white matter, and in the brain steam and the cerebellar peduncles. Their exact etiology is unknown. Their imaging characteristics are somewhat different from those of gray matter. They may represent hamartomas or areas of glial scarring. Differentiation from a small glioma is presently not possible on a single examination

  12. Ichthyoplankton of arvoredo biological marine reserve, Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Thais Rutkowski

    Full Text Available Arvoredo Island, located in Santa Catarina state - south Brazil, and its surrounding area were defined as a Conservation Unit (CU in the category of Biological Reserve since 1990. This research aimed to analyze the inter-annual and seasonal (winter and summer variations of ichthyoplankton densities at Arvoredo Biology Marine Reserve (ABMR, and their relationship with environmental variables in 1997/1998 (Campaign 1, 2007/2008 (Campaign 2 and 2008/2009 (Campaign 3. Fish eggs and larvae were sampled using a WP-2 net with 200 µm mesh size. The study area was influenced by three water masses, (i Coastal Water throughout the whole year, (ii Subtropical Shelf Water during the winter, and (iii South Atlantic Central Water mainly in summer. A total of 4,891 eggs were collected and classified as Engraulidae and Sardinella brasiliensis (Clupeidae. The total number of larvae was 467 belonging to 5 orders, 19 families, and 21 species. Taxonomic composition demonstrated a seasonal pattern among periods, with the highest densities of Engraulidae occurring in winter and the families Carangidae, Clupeidae and Gerreidae in summer. The high number of families and abundance of ichthyoplankton observed in ABMR may be important in supplying the adjacent coastal areas impacted by fishing.

  13. Neuro-ophthalmological assessment of vision before and after radiation therapy alone for pituitary macroadenomas

    International Nuclear Information System (INIS)

    Rush, S.C.; Kupersmith, M.J.; Lerch, I.; Cooper, P.; Ransohoff, J.; Newall, J.

    1990-01-01

    Between 1972 and 1988, 25 patients were treated by radiation therapy (RT) alone for pituitary macroadenomas causing visual impairment. Twenty-three patients were evaluated by a neuro-ophthalmologist before treatment and at the time of follow-up review. Radiation treatment consisted of 4000 to 5000 cGy over 4 to 5 weeks. The median follow-up period was 36 months (range 2 to 192 months). Eighteen patients (78%) experienced visual field improvement. Deterioration occurred in four patients due to tumor recurrence, tumor hemorrhage, possible optic nerve necrosis, and optic chiasm herniation. Visual field improvement occurred predominantly in patients whose pretreatment visual field defects were less than a dense hemianopsia, who did not have diffuse optic atrophy, and who were younger than the median age of 69 years (p less than 0.001). Visual acuity improvement occurred in patients without diffuse optic atrophy, with only mild impairment of the visual acuity, and with only mild visual field loss prior to RT (p less than 0.002). It is concluded that there is a subset of patients with pituitary macroadenomas and visual impairment for whom primary RT is a treatment option

  14. New organic materials for optics: optical storage and nonlinear optics

    International Nuclear Information System (INIS)

    Gan, F.

    1996-01-01

    New organic materials have received considerable attention recently, due to their easy preparation and different variety. The most application fields in optics are optical storage and nonlinear optics. In optical storage the organic dyes have been used for example, in record able and erasable compact disks (CD-R, CD-E) nonlinear optical effects, such as nonlinear optical absorption, second and third order optical absorption, second and third order optical nonlinearities, can be applied for making optical limiters, optical modulators, as well as laser second and third harmonic generations. Due to high value of optical absorption and optical nonlinearity organic materials are always used as thin films in optical integration. In this paper the new experimental results have been presented, and future development has been also discussed. (author)

  15. Parasites and non-fish predators of tilapia with particular reference to the sustainable management of fisheries of Lake Kainji Nigeria

    OpenAIRE

    Okaeme, A.N.; Olufemi, B.E.; Obiekezie, A.

    2001-01-01

    The fisheries of Lake Kainji, Nigeria, experienced a boom year following impoundment, then decline post impoundment and now is in a period of stabilisation of the fish resources. Several reasons have been advanced on factors responsible for these changes, but two outstanding factors are those of nutritional status and fishing methods of the lake. Two important fish families however continue to dominate the lake fisheries in daily fisherman catches: Clupeidae and Cichlidae (tilapias). Recent s...

  16. SoxC transcription factors in retinal development and regeneration

    Directory of Open Access Journals (Sweden)

    Kun-Che Chang

    2017-01-01

    Full Text Available Glaucoma and other optic neuropathies result in optic nerve degeneration and the loss of retinal ganglion cells (RGCs through complex signaling pathways. Although the mechanisms that regulate RGC development remain unclear, uncovering novel developmental pathways may support new strategies to regenerate the optic nerve or replace RGCs. Here we review recent studies that provide strong evidence that the Sry-related high-mobility-group C (SoxC subfamily of transcription factors (TFs are necessary and sufficient for axon guidance and RGC fate specification. These findings also uncover novel SoxC-dependent mechanisms that serve as master regulators during important steps of RGC development. For example, we review work showing that SoxC TFs regulate RGC axon guidance and direction through the optic chiasm towards their appropriate targets in the brain. We also review work demonstrating that Sox11 subcellular localization is, in part, controlled through small ubiquitin-like post-translational modifier (SUMO and suggest compensatory cross-talk between Sox4 and Sox11. Furthermore, Sox4 overexpression is shown to positively drive RGC differentiation in human induced pluripotent stem cells (hiPSCs. Finally, we discuss how these findings may contribute to the advancement of regenerative and cell-based therapies to treat glaucoma and other optic nerve neuropathies.

  17. Soft optics in intelligent optical networks

    Science.gov (United States)

    Shue, Chikong; Cao, Yang

    2001-10-01

    In addition to the recent advances in Hard-optics that pushes the optical transmission speed, distance, wave density and optical switching capacity, Soft-optics provides the necessary intelligence and control software that reduces operational costs, increase efficiency, and enhances revenue generating services by automating optimal optical circuit placement and restoration, and enabling value-added new services like Optical VPN. This paper describes the advances in 1) Overall Hard-optics and Soft-optics 2) Layered hierarchy of Soft-optics 3) Component of Soft-optics, including hard-optics drivers, Management Soft-optics, Routing Soft-optics and System Soft-optics 4) Key component of Routing and System Soft-optics, namely optical routing and signaling (including UNI/NNI and GMPLS signaling). In summary, the soft-optics on a new generation of OXC's enables Intelligent Optical Networks to provide just-in-time service delivery and fast restoration, and real-time capacity management that eliminates stranded bandwidth. It reduces operational costs and provides new revenue opportunities.

  18. Endoscopic Endonasal Surgery for Purely Intrathird Ventricle Craniopharyngioma.

    Science.gov (United States)

    Nishioka, Hiroshi; Fukuhara, Noriaki; Yamaguchi-Okada, Mitsuo; Yamada, Shozo

    2016-07-01

    Extended endoscopic transsphenoidal surgery (EETS) is a safe and effective treatment for many suprasellar craniopharyngiomas, including those with third-ventricle involvement. Craniopharyngioma entirely within the third ventricle (purely intraventricular type), however, is generally regarded unsuitable for treatment with EETS. Three patients underwent total removal of a purely intraventricular craniopharyngioma with inferior extension via EETS by direct incision of the bulging, stretched ventricular floor and fine dissection from the ventricular wall. In 2 patients with an anteriorly displaced chiasm, the space between the chiasm and pituitary stalk created a wide corridor to the ventricle, whereas in the third case, in which the infrachiasmal space was somewhat narrowed, partial sacrifice of the pituitary gland was necessary to obtain sufficient space. Despite preservation of the stalk in 2 patients, hypopituitarism and diabetes insipidus developed after surgery. There was no other complication including obesity. Selected patients with purely intraventricular craniopharyngioma can be treated effectively and safely with EETS. Those with inferior extension in the interpeduncular fossa and anterior displacement of the chiasm may be suitable candidates. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Optical Communication over Plastic Optical Fibers Integrated Optical Receiver Technology

    CERN Document Server

    Atef, Mohamed

    2013-01-01

    This book presents high-performance data transmission over plastic optical fibers (POF) using integrated optical receivers having good properties with multilevel modulation, i.e. a higher sensitivity and higher data rate transmission over a longer plastic optical fiber length. Integrated optical receivers and transmitters with high linearity are introduced for multilevel communication. For binary high-data rate transmission over plastic optical fibers, an innovative receiver containing an equalizer is described leading also to a high performance of a plastic optical fiber link. The cheap standard PMMA SI-POF (step-index plastic optical fiber) has the lowest bandwidth and the highest attenuation among multimode fibers. This small bandwidth limits the maximum data rate which can be transmitted through plastic optical fibers. To overcome the problem of the plastic optical fibers high transmission loss, very sensitive receivers must be used to increase the transmitted length over POF. The plastic optical fiber li...

  20. Pilot study on the distribution of 14C-labeled methaqualone in the rat brain

    International Nuclear Information System (INIS)

    Claus, G.; DeBernardo, E.; Krisko, I.

    1978-01-01

    Methaqualone (2-methyl-3-o-tolyl-4(3H)-quinazolinone) is a hypnotic/sedative, chemically unrelated to other groups of sleep-inducing drugs or major tranquilizers. Measurements have been made of the distribution of radioactive methaqualone in the rat brain up to 24 h after oral administration of the drug. Peak tissue concentrations were found 3 h after intubation. The highest concentrations appeared in the optic chiasm, pituitary gland, and reticular formation of the medulla oblongata. Serum concentrations were approximately one order of magnitude higher than those found in the brain. An apparently inert metabolite was found at 24 h in concentrations which were double those of the peak tissue levels of the compound, both in the brain and in the sera. (U.K.)

  1. Proton therapy for tumors of the skull base

    Energy Technology Data Exchange (ETDEWEB)

    Munzenrider, J.E.; Liebsch, N.J. [Dept. of Radiation Oncology, Harvard Univ. Medical School, Boston, MA (United States)

    1999-06-01

    Charged particle beams are ideal for treating skull base and cervical spine tumors: dose can be focused in the target, while achieving significant sparing of the brain, brain stem, cervical cord, and optic nerves and chiasm. For skull base tumors, 10-year local control rates with combined proton-photon therapy are highest for chondrosarcomas, intermediate for male chordomas, and lowest for female chordomas (94%, 65%, and 42%, respectively). For cervical spine tumors, 10-year local control rates are not significantly different for chordomas and chondrosarcomas (54% and 48%, respectively), nor is there any difference in local control between males and females. Observed treatment-related morbidity has been judged acceptable, in view of the major morbidity and mortality which accompany uncontrolled tumor growth. (orig.)

  2. MRI of craniopharyngiomas

    International Nuclear Information System (INIS)

    Hashimoto, Hiromi; Takemoto, Kazumasa; Shakudo, Miyuki

    1988-01-01

    Magnetic resonance images of 7 patients with surgically confirmed craniopharyngiomas were evaluated and compared with CT scans. Spin echo (SE) images (SE 600 ∼ 1000/40 and SE 1800 ∼ 2500/120) and inversion recovery (IR) images were obtained using a 0.5 T superconductive MR scanner. All cases except one showed hyperintensity on T2-weighted SE images and hypointensity on IR images. Remaining one case had hyperintensity both on T2-weighted SE and IR images. Calcifications were difficult to be detected in the MR images. Coronal and sagittal IR images demonstrated good anatomical relation between the tumor and adjacent brain tissues such as optic chiasm. SE images with a short echo time were useful in delineating tumor contour. (author)

  3. Stubborn hiccups as a sign of massive apoplexy in a naive acromegaly patient with pituitary macroadenoma

    Directory of Open Access Journals (Sweden)

    Gulay Simsek Bagir

    2017-05-01

    Full Text Available Pituitary apoplexy (PA may very rarely present with hiccups. A 32-year-old man with classical acromegaloid features was admitted with headache, nausea, vomiting and stubborn hiccups. Pituitary magnetic resonance imaging (MRI demonstrated apoplexy of a macroadenoma with suprasellar extension abutting the optic chiasm. Plasma growth hormone (GH levels exhibited suppression (below <1 ng/mL at all time points during GH suppression test with 75 g oral glucose. After treatment with corticosteroid agents, he underwent transsphenoidal pituitary surgery and hiccups disappeared postoperatively. The GH secretion potential of the tumor was clearly demonstrated immunohistochemically. We conclude that stubborn hiccups in a patient with a pituitary macroadenoma may be a sign of massive apoplexy that may result in hormonal remission.

  4. Proton therapy for tumors of the skull base

    International Nuclear Information System (INIS)

    Munzenrider, J.E.; Liebsch, N.J.

    1999-01-01

    Charged particle beams are ideal for treating skull base and cervical spine tumors: dose can be focused in the target, while achieving significant sparing of the brain, brain stem, cervical cord, and optic nerves and chiasm. For skull base tumors, 10-year local control rates with combined proton-photon therapy are highest for chondrosarcomas, intermediate for male chordomas, and lowest for female chordomas (94%, 65%, and 42%, respectively). For cervical spine tumors, 10-year local control rates are not significantly different for chordomas and chondrosarcomas (54% and 48%, respectively), nor is there any difference in local control between males and females. Observed treatment-related morbidity has been judged acceptable, in view of the major morbidity and mortality which accompany uncontrolled tumor growth. (orig.)

  5. The treatment of extensive scalp lesions using coplanar and non-coplanar photon IMRT: a single institution experience

    International Nuclear Information System (INIS)

    Ostheimer, Christian; Janich, Martin; Hübsch, Patrick; Gerlach, Reinhard; Vordermark, Dirk

    2014-01-01

    This clinical study compared four different cases of extensive scalp malignancies treated by intensity-modulated radiation therapy. The merits of coplanar and non-coplanar Step-and-shoot total scalp irradiation techniques were evaluated against the background of the literature. Four patients (angiosarcoma, n=2, cutaneous B-cell non-Hodgkin lymphoma, B-NHL, n=1, mycosis fungoides, n=1) treated between 2008 and 2012 at our institution were retrospectively analyzed. For every patient with executed coplanar plan, a non-coplanar plan and vice versa has been calculated additionally for direct comparison. Three patients underwent limited surgery before radiotherapy. Individual adapted bolus material was used for every patient (helmet). Total scalp dose was 30 Gy (B-NHL, mycosis fungoides) and 50 Gy (angiosarcoma) with fractional doses of 2.0-2.5 Gy (without sequential local boost in three patients). Conformity and homogeneity indexes and dose volume histograms were used for treatment plan comparison. Dose hot spots were higher in coplanar plans (110-128% Dmax). Non-coplanar plans showed a more homogeneous dose distribution (HI = .12 - .17) and superior PTV coverage (88 - 96%). Target dose coverage was 81-117% in non-coplanar and 30-128% in coplanar plans. Coplanar plans yielded a stronger dose gradient across the target (.7-1.6 Gy/mm) compared to non-coplanar plans (.8-1.3 Gy/mm). The most conformal plan was a non-coplanar plan (CI = .7). Mean and maximum brain doses were comparable and showed an almost linear decrease between min. and max. dose. The optic chiasm and brain stem was spared most with non-coplanar plans, mean doses to the lenses ranged between 4 and 8 Gy and were higher in non-coplanar plans as were doses to the optic nerves. Radiotherapy tolerance was acceptable and acute side effects included erythema, scalp pain, alopecia and radiodermatitis which all spontaneously resolved. Two patients accomplished partial response, two patients showed complete response

  6. Spatial and temporal distribution of fish eggs and larvae in a subtropical coastal lagoon, Santa Catarina State, Brazil

    Directory of Open Access Journals (Sweden)

    Luis C. P. Macedo-Soares

    Full Text Available This study investigated the variation in abundance, distribution and composition of ichthyoplankton in a lagoon in southern Brazil through the year and at different stations within the lagoon. Ibiraquera Lagoon is a shallow coastal lagoon connected to the sea by a semi-permanent sandbar. Ichthyoplankton samples were collected monthly from December 2003 to December 2004, with a 200 µm mesh net using horizontal surface hauls. A colder, drier period was detected, contrasting with warm months during which salinity varied depending on rainfall and whether the sandbar was open or closed. The mean abundance of ichthyoplankton over the study period was 459.6 ± 76.2 (SE eggs · 100 m-3 and 63.6 ± 7.9 (SE larvae · 100 m-3, and they were present during all months. Significantly higher abundances of eggs and larvae were observed during warm months. The community was dominated by the family Engraulidae followed by Clupeidae, Gobiidae and Mugilidae. Engraulidae and Clupeidae were present throughout the year, with greater abundances in months with higher temperatures. Some coastal fish species spawn in Ibiraquera Lagoon, mainly near to the sandbar, demonstrating that the lagoon is a spawning area for coastal stock. We recommend the establishment of environmental procedures to promote the conservation of Ibiraquera Lagoon and its ichthyoplankton community.

  7. BMP7 and SHH regulate Pax2 in mouse retinal astrocytes by relieving TLX repression.

    Science.gov (United States)

    Sehgal, Rachna; Sheibani, Nader; Rhodes, Simon J; Belecky Adams, Teri L

    2009-08-15

    Pax2 is essential for development of the neural tube, urogenital system, optic vesicle, optic cup and optic tract. In the eye, Pax2 deficiency is associated with coloboma, a loss of astrocytes in the optic nerve and retina, and abnormal axonal pathfinding of the ganglion cell axons at the optic chiasm. Thus, appropriate expression of Pax2 is essential for astrocyte determination and differentiation. Although BMP7 and SHH have been shown to regulate Pax2 expression, the molecular mechanism by which this regulation occurs is not well understood. In this study, we determined that BMP7 and SHH activate Pax2 expression in mouse retinal astrocyte precursors in vitro. SHH appeared to play a dual role in Pax2 regulation; 1) SHH may regulate BMP7 expression, and 2) the SHH pathway cooperates with the BMP pathway to regulate Pax2 expression. BMP and SHH pathway members can interact separately or together with TLX, a repressor protein in the tailless transcription factor family. Here we show that the interaction of both pathways with TLX relieves the repression of Pax2 expression in mouse retinal astrocytes. Together these data reveal a new mechanism for the cooperative actions of signaling pathways in astrocyte determination and differentiation and suggest interactions of regulatory pathways that are applicable to other developmental programs.

  8. Applied optics and optical design

    CERN Document Server

    Conrady, Alexander Eugen

    1957-01-01

    ""For the optical engineer it is an indispensable work."" - Journal, Optical Society of America""As a practical guide this book has no rival."" - Transactions, Optical Society""A noteworthy contribution,"" - Nature (London)Part I covers all ordinary ray-tracing methods, together with the complete theory of primary aberrations and as much of higher aberration as is needed for the design of telescopes, low-power microscopes and simple optical systems. Chapters: Fundamental Equations, Spherical Aberration, Physical Aspect of Optical Images, Chromatic Aberration, Design of Achromatic Object-Glass

  9. Recovery from diabetes insipidus and preservation of thyroid function after craniopharyngioma removal and pituitary stalk sectioning.

    Science.gov (United States)

    Ogawa, Yoshikazu; Niizuma, Kuniyasu; Tominaga, Teiji

    2017-11-01

    Craniopharyngioma is a slow-growing tumor, but long-term tumor control with maintenance of quality of life is sometimes very difficult to achieve, and hypothalamic disturbance should be strictly avoided in the treatment. However, management of the pituitary gland and/or pituitary stalk varies among surgeons and institutions. This retrospective review identified 44 patients, 24 males and 20 females with craniopharyngiomas who were initially treated by surgery through the extended transsphenoidal approach with pituitary stalk sectioning at a single institute. If the tumor bed involved the posterior lobe of the pituitary gland, pituitary stalk, anterior and/or mid portion of the third ventricle floor, these structures were removed en-bloc together with the tumor. The closest attention was paid to preserve fine arteries running along the surface of optic chiasm and the lateral walls of the third ventricle. Surgical outcome and changes in postoperative endocrinological status were investigated. Gross total removal was achieved in 40 of 44 patients (91%), and all patients could discharge without autonomic and/or thermal disturbances. Tumor remnants were identified with tight adhesion to the perforating arteries in 2 cases, tight adhesion to mammillary bodies in 1, and optic chiasm in 1. Administration of anti-diuretic hormone could be discontinued in 23 of 44 patients (52.3%) with improved diabetes insipidus (DI), although no patient could discontinue glucocorticoid administration. Preservation of thyroid function was achieved in another 23 of 44 patients (52.3%), and recovery from DI was correlated with preservation of thyroid function (p=0.016). Pituitary dysfunction is partially reversible even with pituitary stalk sectioning. Regrowth of tumor in the anterior and/or mid portion of the third ventricle floor including pituitary stalk can possibly be prevented by aggressive tumor removal, and co-achievement of long-term tumor control with maintenance of quality of life

  10. Adjuvant or radical fractionated stereotactic radiotherapy for patients with pituitary functional and nonfunctional macroadenoma

    Directory of Open Access Journals (Sweden)

    Weber Damien C

    2011-12-01

    Full Text Available Abstract Purpose To evaluate the efficacy and toxicity of stereotactic fractionated radiotherapy (SFRT for patients with pituitary macroadenoma (PMA. Methods and Materials Between March 2000 and March 2009, 27 patients (male to female ratio, 1.25 with PMA underwent SFRT (median dose, 50.4 Gy. Mean age of the patients was 56.5 years (range, 20.3 - 77.4. In all but one patient, SFRT was administered for salvage treatment after surgical resection (transphenoidal resection in 23, transphenoidal resection followed by craniotomy in 2 and multiple transphenoidal resections in another patient. In 10 (37% patients, the PMAs were functional (3 ACTH-secreting, 3 prolactinomas, 2 growth hormone-secreting and 2 multiple hormone-secretion. Three (11.1% and 9 (33.3% patients had PMA abutting and compressing the optic chiasm, respectively. Mean tumor volume was 2.9 ± 4.6 cm3. Eighteen (66.7% patients had hypopituitarism prior to SFRT. The mean follow-up period after SFRT was 72.4 ± 37.2 months. Results Tumor size decreased for 6 (22.2% patients and remained unchanged for 19 (70.4% other patients. Two (7.4% patients had tumor growth inside the prescribed treatment volume. The estimated 5-year tumor growth control was 95.5% after SFRT. Biochemical remission occurred in 3 (30% patients with functional PMA. Two patients with normal anterior pituitary function before SFRT developed new deficits 25 and 65 months after treatment. The 5-year survival without new anterior pituitary deficit was thus 95.8%. Five patients with visual field defect had improved visual function and 1 patient with no visual defect prior to SFRT, but an optic chiasm abutting tumor, had a decline in visual function. The estimated 5-year vision and pituitary function preservation rates were 93.2% and 95.8%, respectively. Conclusions SFRT is a safe and effective treatment for patients with PMA, although longer follow-up is needed to evaluate long-term outcomes. In this study, approximately 1

  11. Adjuvant or radical fractionated stereotactic radiotherapy for patients with pituitary functional and nonfunctional macroadenoma

    International Nuclear Information System (INIS)

    Weber, Damien C; Momjian, Shahan; Pralong, François P; Meyer, Patrick; Villemure, Jean Guy; Pica, Alessia

    2011-01-01

    To evaluate the efficacy and toxicity of stereotactic fractionated radiotherapy (SFRT) for patients with pituitary macroadenoma (PMA). Between March 2000 and March 2009, 27 patients (male to female ratio, 1.25) with PMA underwent SFRT (median dose, 50.4 Gy). Mean age of the patients was 56.5 years (range, 20.3 - 77.4). In all but one patient, SFRT was administered for salvage treatment after surgical resection (transphenoidal resection in 23, transphenoidal resection followed by craniotomy in 2 and multiple transphenoidal resections in another patient). In 10 (37%) patients, the PMAs were functional (3 ACTH-secreting, 3 prolactinomas, 2 growth hormone-secreting and 2 multiple hormone-secretion). Three (11.1%) and 9 (33.3%) patients had PMA abutting and compressing the optic chiasm, respectively. Mean tumor volume was 2.9 ± 4.6 cm 3 . Eighteen (66.7%) patients had hypopituitarism prior to SFRT. The mean follow-up period after SFRT was 72.4 ± 37.2 months. Tumor size decreased for 6 (22.2%) patients and remained unchanged for 19 (70.4%) other patients. Two (7.4%) patients had tumor growth inside the prescribed treatment volume. The estimated 5-year tumor growth control was 95.5% after SFRT. Biochemical remission occurred in 3 (30%) patients with functional PMA. Two patients with normal anterior pituitary function before SFRT developed new deficits 25 and 65 months after treatment. The 5-year survival without new anterior pituitary deficit was thus 95.8%. Five patients with visual field defect had improved visual function and 1 patient with no visual defect prior to SFRT, but an optic chiasm abutting tumor, had a decline in visual function. The estimated 5-year vision and pituitary function preservation rates were 93.2% and 95.8%, respectively. SFRT is a safe and effective treatment for patients with PMA, although longer follow-up is needed to evaluate long-term outcomes. In this study, approximately 1 patient with visual field defect out of two had an improved

  12. Visual System Involvement in Patients with Newly Diagnosed Parkinson Disease.

    Science.gov (United States)

    Arrigo, Alessandro; Calamuneri, Alessandro; Milardi, Demetrio; Mormina, Enricomaria; Rania, Laura; Postorino, Elisa; Marino, Silvia; Di Lorenzo, Giuseppe; Anastasi, Giuseppe Pio; Ghilardi, Maria Felice; Aragona, Pasquale; Quartarone, Angelo; Gaeta, Michele

    2017-12-01

    Purpose To assess intracranial visual system changes of newly diagnosed Parkinson disease in drug-naïve patients. Materials and Methods Twenty patients with newly diagnosed Parkinson disease and 20 age-matched control subjects were recruited. Magnetic resonance (MR) imaging (T1-weighted and diffusion-weighted imaging) was performed with a 3-T MR imager. White matter changes were assessed by exploring a white matter diffusion profile by means of diffusion-tensor imaging-based parameters and constrained spherical deconvolution-based connectivity analysis and by means of white matter voxel-based morphometry (VBM). Alterations in occipital gray matter were investigated by means of gray matter VBM. Morphologic analysis of the optic chiasm was based on manual measurement of regions of interest. Statistical testing included analysis of variance, t tests, and permutation tests. Results In the patients with Parkinson disease, significant alterations were found in optic radiation connectivity distribution, with decreased lateral geniculate nucleus V2 density (F, -8.28; P Parkinson disease and that the entire intracranial visual system can be involved. © RSNA, 2017 Online supplemental material is available for this article.

  13. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  14. Light Optics for Optical Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andorf, Matthew [NICADD, DeKalb; Lebedev, Valeri [Fermilab; Piot, Philippe [NICADD, DeKalb; Ruan, Jinhao [Fermilab

    2016-06-01

    In Optical Stochastic Cooling (OSC) radiation generated by a particle in a "pickup" undulator is amplified and transported to a downstream "kicker" undulator where it interacts with the same particle which radiated it. Fermilab plans to carry out both passive (no optical amplifier) and active (optical amplifier) tests of OSC at the Integrable Optics Test Accelerator (IOTA) currently in construction*. The performace of the optical system is analyzed with simulations in Synchrotron Radiation Workshop (SRW) accounting for the specific temporal and spectral properties of undulator radiation and being augmented to include dispersion of lens material.

  15. Optical materials

    International Nuclear Information System (INIS)

    Poker, D.B.; Ortiz, C.

    1989-01-01

    This book reports on: Diamond films, Synthesis of optical materials, Structure related optical properties, Radiation effects in optical materials, Characterization of optical materials, Deposition of optical thin films, and Optical fibers and waveguides

  16. Eoalosa janvieri gen. et sp. nov., a new clupeid fish (Teleostei, Clupeiformes) from the Eocene of Monte Bolca, Italy.

    Science.gov (United States)

    Marramà, Giuseppe; Carnevale, Giorgio

    2018-01-01

    Fishes of the family Clupeidae are extremely abundant in the Eocene fossiliferous limestone of Monte Bolca representing the most common group from this celebrated locality. A new clupeid from the Pesciara site, Eoalosa janvieri gen. et sp. nov., is described. The new taxon exhibits a unique combination of characters supporting its recognition as a new genus and species of clupeid fish that is tentatively placed in the subfamily Alosinae. The description of this new taxon improves our knowledge of the diversity of clupeoid fishes in the Eocene of Monte Bolca.

  17. Chirality in nonlinear optics and optical switching

    NARCIS (Netherlands)

    Meijer, E.W.; Feringa, B.L.

    1993-01-01

    Chirality in molecular opto-electronics is limited sofar to the use of optically active liquid crystals and a number of optical phenomena are related to the helical macroscopic structure obtained by using one enantiomer, only. In this paper, the use of chirality in nonlinear optics and optical

  18. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  19. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  20. Semiconductor optical amplifier-based all-optical gates for high-speed optical processing

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    2000-01-01

    Semiconductor optical amplifiers are useful building blocks for all-optical gates as wavelength converters and OTDM demultiplexers. The paper reviews the progress from simple gates using cross-gain modulation and four-wave mixing to the integrated interferometric gates using cross-phase modulation....... These gates are very efficient for high-speed signal processing and open up interesting new areas, such as all-optical regeneration and high-speed all-optical logic functions...

  1. Bio-Optics and Bio-Inspired Optical Materials.

    Science.gov (United States)

    Tadepalli, Sirimuvva; Slocik, Joseph M; Gupta, Maneesh K; Naik, Rajesh R; Singamaneni, Srikanth

    2017-10-25

    Through the use of the limited materials palette, optimally designed micro- and nanostructures, and tightly regulated processes, nature demonstrates exquisite control of light-matter interactions at various length scales. In fact, control of light-matter interactions is an important element in the evolutionary arms race and has led to highly engineered optical materials and systems. In this review, we present a detailed summary of various optical effects found in nature with a particular emphasis on the materials and optical design aspects responsible for their optical functionality. Using several representative examples, we discuss various optical phenomena, including absorption and transparency, diffraction, interference, reflection and antireflection, scattering, light harvesting, wave guiding and lensing, camouflage, and bioluminescence, that are responsible for the unique optical properties of materials and structures found in nature and biology. Great strides in understanding the design principles adapted by nature have led to a tremendous progress in realizing biomimetic and bioinspired optical materials and photonic devices. We discuss the various micro- and nanofabrication techniques that have been employed for realizing advanced biomimetic optical structures.

  2. Neuronal apoptosis and neurofilament protein expression in the lateral geniculate body of cats following acute optic nerve injuries

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    BACKGROUND: The visual pathway have 6 parts, involving optic nerve, optic chiasm, optic tract, lateral geniculate body, optic radiation and cortical striatum area. Corresponding changes may be found in these 6 parts following optic nerve injury. At present, studies mainly focus on optic nerve and retina, but studies on lateral geniculate body are few.OBJECTIVE: To prepare models of acute optic nerve injury for observing the changes of neurons in lateral geniculate body, expression of neurofilament protein at different time after injury and cell apoptosis under the optical microscope, and for investigating the changes of neurons in lateral geniculate body following acute optic nerve injury.DESIGN: Completely randomized grouping design, controlled animal experiment.SETTING: Department of Neurosurgery, General Hospital of Ji'nan Military Area Command of Chinese PLA.MATERIALS: Twenty-eight adult healthy cats of either gender and common grade, weighing from 2.0 to 3.5 kg, were provided by the Animal Experimental Center of Fudan University. The involved cats were divided into 2 groups according to table of random digit: normal control group (n =3) and model group (n =25). Injury 6 hours, 1, 3, 7 and 14 days five time points were set in model group for later observation, 5 cats at each time point. TUNEL kit (Bohringer-Mannheim company)and NF200& Mr 68 000 mouse monoclonal antibody (NeoMarkers Company) were used in this experiment.METHODS: This experiment was carried out in the Department of Neurosurgery, General Hospital of Ji'nan Military Area Command of Chinese PLA between June 2004 and June 2005. ① The cats of model group were developed into cat models of acute intracranial optic nerve injury as follows: The anesthetized cats were placed in lateral position. By imitating operation to human, pterion approach was used. An incision was made at the joint line between outer canthus and tragus, and deepened along cranial base until white optic nerve via optic nerve pore

  3. Monolithically integrated quantum dot optical modulator with Semiconductor optical amplifier for short-range optical communications

    Science.gov (United States)

    Yamamoto, Naokatsu; Akahane, Kouichi; Umezawa, Toshimasa; Kawanishi, Tetsuya

    2015-04-01

    A monolithically integrated quantum dot (QD) optical gain modulator (OGM) with a QD semiconductor optical amplifier (SOA) was successfully developed. Broadband QD optical gain material was used to achieve Gbps-order high-speed optical data transmission, and an optical gain change as high as approximately 6-7 dB was obtained with a low OGM voltage of 2.0 V. Loss of optical power due to insertion of the device was also effectively compensated for by the SOA section. Furthermore, it was confirmed that the QD-OGM/SOA device helped achieve 6.0-Gbps error-free optical data transmission over a 2.0-km-long photonic crystal fiber. We also successfully demonstrated generation of Gbps-order, high-speed, and error-free optical signals in the >5.5-THz broadband optical frequency bandwidth larger than the C-band. These results suggest that the developed monolithically integrated QD-OGM/SOA device will be an advantageous and compact means of increasing the usable optical frequency channels for short-reach communications.

  4. Fractionated, three-dimensional, planning-assisted proton-radiation therapy for orbital rhabdomyosarcoma: a novel technique

    International Nuclear Information System (INIS)

    Hug, Eugen B.; Adams, Judy; Fitzek, Markus; Vries, Alexander de; Munzenrider, John E.

    2000-01-01

    Purpose: Most children with orbital rhabdomyosarcoma will survive their disease. However, conventional photon-radiation treatment, as part of multimodality therapy, results in varying degrees of long-term functional and cosmetic side effects. This report introduces external beam proton radiation therapy (PRT) as a conformal, three-dimensional planned radiation technique for this disease, analyzes normal tissue dosimetry, and describes the technique's application in the first 2 patients. Material and Methods: Between January 1995 and February 1996, 2 patients underwent PRT following biopsy and chemotherapy for orbital rhabdomyosarcoma. Fifty and 55 Cobalt Gray Equivalent (CGE) were delivered to the gross tumor volume and 40 CGE to clinical target volumes in both patients. A relative biologic effectiveness (RBE) of 1.1 was utilized to correlate proton dose calculations with CGE. To achieve dose conformity, a ''patch technique'' was utilized, where target regions were divided into segments, each treated by a separate proton field. Dose-volume histograms were obtained for target and nontarget regions, including lens, bony orbit, pituitary gland, optic chiasm, optic nerves, lacrimal gland, and ipsilateral frontal and temporal lobes. Results: At 3.4 and 2.5 years after PRT, both patients are clinically and radiographically free of disease. Visual acuity remains excellent, without signs of cataract formation; pituitary function is normal; cosmetically, only mild enophthalmos is noticeable. Doses to 90%, 50%, and 5% of lens volume were kept at less than 1%, less than 2%, and less than 8%, respectively. Fifty percent of lacrimal gland volume received less than 36% of the prescribed dose and 50% of the volume of the optic chiasm, pituitary gland, and hypothalamus were restricted to less than 2%. Proton conformity to orbital contents resulted in between 9% and 36% of the prescribed dose reaching the ipsilateral temporal and frontal lobes immediately adjacent to bony orbit (5

  5. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  6. Infantile neuroaxonal dystrophy: neuroradiological studies in 11 patients

    International Nuclear Information System (INIS)

    Farina, L.; Bruzzone, M.G.; D'Incerti, L.; Savoiardo, M.; Nardocci, N.; Zorzi, G.; Verga, L.; Morbin, M.

    1999-01-01

    We report the imaging findings in 11 patients with infantile neuroaxonal dystrophy. Ten patients underwent 15 MRI examinations; one patient had only CT. Of the ten patients who underwent MRI, eight had cerebellar atrophy and mildly increased signal from the cerebellar cortex on T2-weighted images. With T2 weighting there was slightly increased signal from the dentate nuclei in two patients and from the posterior periventricular white matter in three. We saw four patients with a thin optic chiasm. The only two brothers in the series had markedly low signal from the globus pallidus and substantia nigra on 1.5 T T2-weighted images, as seen in Hallervorden-Spatz disease (HSD). Abnormalities of the globus pallidus may be related to a protracted course of the disease. However, an overlap with HSD should be considered. (orig.)

  7. A comparison of the value of MRI and CT in patients with Nelson syndrome

    International Nuclear Information System (INIS)

    Kersjes, W.; Allmendinger, S.; Christ, F.; Stiebler, H.; Bockisch, A.; Klingmueller, D.

    1992-01-01

    The hypophyses of 13 patients with Nelson syndrome following bilateral adrenalectomy were examined by MRI and CT. Diffuse enlargement of the hypophysis was demonstrated in 8 patients by CT and in 9 by MRI. Compared with CT, MRI provides better demonstration of tumour development, such as abnormal convexity of the cranial margin of the hypophysis (MRI 4/13, CT 1/13), displacement of the infundibulum (MRI 4/13, CT 0/13) or optic chiasm (MRI 2/13, CT 0/13). MRI also provides diagnostically important differentiation between scar tissue and recurrence of tumour following hypophysectomy (MRI 1/3, CT 0/3) and more accurate demonstration of infiltration of the cavernous sinus (MRI 4/13, CT 2/13). CT is superior only in showing the floor of the sella. MRI is the method of choice for imaging in cases of Nelson syndrome. (orig.) [de

  8. A Case of Rathke’s Cleft Cyst Associated with Transient Central Adrenal Insufficiency and Masked Diabetes Insipidus

    Directory of Open Access Journals (Sweden)

    Masahiro Asakawa

    2014-01-01

    Full Text Available A 73-year-old woman admitted to our hospital because of headache, poor appetite, malaise, weight loss, and vomiting was found to have central adrenal insufficiency and thyrotoxicosis due to silent thyroiditis. Polyuria developed after replacement with glucocorticoid (masked diabetes insipidus, which was controlled with nasal administration of desmopressin. Magnetic resonance imaging of the brain showed a large cystic pituitary mass (18 × 18 × 12 mm extending suprasellarly to the optic chiasm. Transsphenoidal surgery revealed that the pituitary tumor was Rathke’s cleft cyst. Following surgery, replacement with neither glucocorticoid nor desmopressin was needed any more. Therefore, it is suggested that Rathke’s cleft cyst is responsible for the masked diabetes insipidus and the central insufficiency. Furthermore, it is speculated that thyrotoxicosis with painless thyroiditis might induce changes from subclinical adrenal insufficiency to transiently overt insufficiency.

  9. Early blindness and coma during intrathecal chemotherapy for meningeal carcinomatosis.

    Science.gov (United States)

    Boogerd, W; Moffie, D; Smets, L A

    1990-02-01

    A 35-year-old woman was treated with intraventricular methotrexate (MTX) with a total dose of 70 mg followed by cytosine arabinoside (Ara-C) with a total dose of 80 mg for meningeal metastasis of breast carcinoma. Radiation therapy was not given. Despite a response of the meningeal tumor the patient developed in the third week of MTX treatment a progressive visual loss and loss of consciousness which worsened during subsequent Ara-C treatment and led to death within 3 weeks. Postmortem examination revealed only minimal neoplastic infiltration of the meninges. Multiple foci of axonal degeneration and demyelination were found in the optic nerves and chiasm, the superficial layers of the brainstem, and spinal cord and to some extent in other cranial nerves and spinal nerve roots. The possible causes of this previously unreported early complication are discussed.

  10. Pig brain stereotaxic standard space: Mapping of cerebral blood flow normative values and effect of MPTP-lesioning

    DEFF Research Database (Denmark)

    Andersen, F.; Watanabe, H.; Bjarkam, C.R.

    2005-01-01

    The analysis of physiological processes in brain by position emission tomography (PET) is facilitated when images are spatially normalized to a standard coordinate system. Thus, PET activation studies of human brain frequently employ the common stereotaxic coordinates of Talairach. We have...... developed an analogous stereotaxic coordinate system for the brain of the Gottingen miniature pig, based on automatic co-registration of magnetic resonance (MR) images obtained in 22 male pigs. The origin of the pig brain stereotaxic space (0, 0, 0) was arbitrarily placed in the centroid of the pineal gland...... as identified on the average MRI template. The orthogonal planes were imposed using the line between stereotaxic zero and the optic chiasm. A series of mean MR images in the coronal, sagittal and horizontal planes were generated. To test the utility of the common coordinate system for functional imaging studies...

  11. Reconfigurable optical-to-optical frequency conversion method and apparatus

    Science.gov (United States)

    Zortman, William A.; Lentine, Anthony L.

    2017-04-18

    A photonic device is provided for impressing a modulation pattern on an optical carrier. The device includes a unit in which a photodetector and an optical microresonator are monolithically integrated. The device further includes an optical waveguide evanescently coupled to the optical microresonator and having at least an upstream portion configured to carry at least one optical carrier toward the microresonator. The optical microresonator is tunable so as to resonate with the optical carrier frequency. The optical microresonator and the photodetector are mutually coupled such that in operation, charge carriers photogenerated in the photodetector are injected into the microresonator, where the photocurrent changes the resonant conditions. In some embodiments the device is operable as an optical-to-optical frequency converter. In other embodiments the device is operable as an oscillator.

  12. Magneto-Optic Field Coupling in Optical Fiber Bragg Gratings

    Science.gov (United States)

    Carman, Gregory P. (Inventor); Mohanchandra, Panduranga K. (Inventor); Emmons, Michael C. (Inventor); Richards, William Lance (Inventor)

    2016-01-01

    The invention is a magneto-optic coupled magnetic sensor that comprises a standard optical fiber Bragg grating system. The system includes an optical fiber with at least one Bragg grating therein. The optical fiber has at least an inner core and a cladding that surrounds the inner core. The optical fiber is part of an optical system that includes an interrogation device that provides a light wave through the optical fiber and a system to determine the change in the index of refraction of the optical fiber. The cladding of the optical fiber comprises at least a portion of which is made up of ferromagnetic particles so that the ferromagnetic particles are subject to the light wave provided by the interrogation system. When a magnetic field is present, the ferromagnetic particles change the optical properties of the sensor directly.

  13. Multifocal visual evoked potential in optic neuritis, ischemic optic neuropathy and compressive optic neuropathy

    Science.gov (United States)

    Jayaraman, Manju; Gandhi, Rashmin Anilkumar; Ravi, Priya; Sen, Parveen

    2014-01-01

    Purpose: To investigate the effect of optic neuritis (ON), ischemic optic neuropathy (ION) and compressive optic neuropathy (CON) on multifocal visual evoked potential (mfVEP) amplitudes and latencies, and to compare the parameters among three optic nerve disorders. Materials and Methods: mfVEP was recorded for 71 eyes of controls and 48 eyes of optic nerve disorders with subgroups of optic neuritis (ON, n = 21 eyes), ischemic optic neuropathy (ION, n = 14 eyes), and compressive optic neuropathy (CON, n = 13 eyes). The size of defect in mfVEP amplitude probability plots and relative latency plots were analyzed. The pattern of the defect in amplitude probability plot was classified according to the visual field profile of optic neuritis treatment trail (ONTT). Results: Median of mfVEP amplitude (log SNR) averaged across 60 sectors were reduced in ON (0.17 (0.13-0.33)), ION (0.14 (0.12-0.21)) and CON (0.21 (0.14-0.30)) when compared to controls. The median mfVEP relative latencies compared to controls were significantly prolonged in ON and CON group of 10.53 (2.62-15.50) ms and 5.73 (2.67-14.14) ms respectively compared to ION group (2.06 (-4.09-13.02)). The common mfVEP amplitude defects observed in probability plots were diffuse pattern in ON, inferior altitudinal defect in ION and temporal hemianopia in CON eyes. Conclusions: Optic nerve disorders cause reduction in mfVEP amplitudes. The extent of delayed latency noted in ischemic optic neuropathy was significantly lesser compared to subjects with optic neuritis and compressive optic neuropathy. mfVEP amplitudes can be used to objectively assess the topography of the visual field defect. PMID:24088641

  14. Optical near-fields & nearfield optics

    OpenAIRE

    Meixner, Alfred J; Leiderer, Paul

    2014-01-01

    Optical methods provide exceedingly powerful tools in science and technology for measuring, analyzing and manipulating, from optical microscopy and spectroscopy to the characterization of ultrafast processes by femtosecond pulses and the modification of materials by intense laser radiation. However, when it comes to applications in the nanometer-regime, the conventional optical techniques suffer from the resolution limit – formulated by Ernst Abbe one and a half centuries ago – that light can...

  15. Design of optical switches by illusion optics

    International Nuclear Information System (INIS)

    Shoorian, H R; Abrishamian, M S

    2013-01-01

    In this paper, illusion optics theory is employed to form Bragg gratings in an optical waveguide in order to design an optical switch. By using an illusion device at a certain distance from the waveguide, the effective refractive index of the waveguide is remotely modulated, turning the waveguide into a distributed Bragg reflector (DBR) which blocks the waves at a stop band. By removing the illusion device, the waves propagate through the waveguide again. In addition, this method is used to remotely tune DBR optical properties such as resonant frequency and bandwidth in a wide range, which leads to a tunable filter for optical switching applications. Finally, using an illusion device at a distance, an optical cavity is created by inserting defects remotely in a DBR without any physical damage in the primary device. (paper)

  16. Design of optical switches by illusion optics

    Science.gov (United States)

    Shoorian, H. R.; Abrishamian, M. S.

    2013-05-01

    In this paper, illusion optics theory is employed to form Bragg gratings in an optical waveguide in order to design an optical switch. By using an illusion device at a certain distance from the waveguide, the effective refractive index of the waveguide is remotely modulated, turning the waveguide into a distributed Bragg reflector (DBR) which blocks the waves at a stop band. By removing the illusion device, the waves propagate through the waveguide again. In addition, this method is used to remotely tune DBR optical properties such as resonant frequency and bandwidth in a wide range, which leads to a tunable filter for optical switching applications. Finally, using an illusion device at a distance, an optical cavity is created by inserting defects remotely in a DBR without any physical damage in the primary device.

  17. Progress in nano-electro optics characterization of nano-optical materials and optical near-field interactions

    CERN Document Server

    Ohtsu, Motoichi

    2005-01-01

    This volume focuses on the characterization of nano-optical materials and optical-near field interactions. It begins with the techniques for characterizing the magneto-optical Kerr effect and continues with methods to determine structural and optical properties in high-quality quantum wires with high spatial uniformity. Further topics include: near-field luminescence mapping in InGaN/GaN single quantum well structures in order to interpret the recombination mechanism in InGaN-based nano-structures; and theoretical treatment of the optical near field and optical near-field interactions, providing the basis for investigating the signal transport and associated dissipation in nano-optical devices. Taken as a whole, this overview will be a valuable resource for engineers and scientists working in the field of nano-electro-optics.

  18. Optical Performance Monitoring and Signal Optimization in Optical Networks

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2006-01-01

    The thesis studies performance monitoring for the next generation optical networks. The focus is on all-optical networks with bit-rates of 10 Gb/s or above. Next generation all-optical networks offer large challenges as the optical transmitted distance increases and the occurrence of electrical-optical......-electrical regeneration points decreases. This thesis evaluates the impact of signal degrading effects that are becoming of increasing concern in all-optical high-speed networks due to all-optical switching and higher bit-rates. Especially group-velocity-dispersion (GVD) and a number of nonlinear effects will require...... enhanced attention to avoid signal degradations. The requirements for optical performance monitoring features are discussed, and the thesis evaluates the advantages and necessity of increasing the level of performance monitoring parameters in the physical layer. In particular, methods for optical...

  19. All-optical signal processing for optical packet switching networks

    NARCIS (Netherlands)

    Liu, Y.; Hill, M.T.; Calabretta, N.; Tangdiongga, E.; Geldenhuys, R.; Zhang, S.; Li, Z.; Waardt, de H.; Khoe, G.D.; Dorren, H.J.S.; Iftekharuddin, K.M.; awwal, A.A.S.

    2005-01-01

    We discuss how all-optical signal processing might play a role in future all-optical packet switched networks. We introduce a concept of optical packet switches that employ entirely all-optical signal processing technology. The optical packet switch is made out of three functional blocks: the

  20. Feasibility of Optical Instruments Based on Multiaperture Optics.

    Science.gov (United States)

    1984-10-16

    system may be configured. The optical elements may be nonimaging concentrators (light horns), the field of view (FOV) of which may be controlled by a...RD-RI58 868 FEASIBILITY OF OPTICAL INSTRUMENTS BASED ON i/I MULTIAPERTURE OPTICS (U) FLORIDA UNIV GAINESVILLE DEPT OF NUCLEAR ENGINEERING SCIENCES J D...d Subtitle) 5. TYPE OF REPORT & PERIOD COVERED ’ 0 Feasibility of Optical Instruments Based on Final Report * CD Multiaperature Optics 615/83 to 9/30

  1. Nonlinear optics

    International Nuclear Information System (INIS)

    Boyd, R.W.

    1992-01-01

    Nonlinear optics is the study of the interaction of intense laser light with matter. This book is a textbook on nonlinear optics at the level of a beginning graduate student. The intent of the book is to provide an introduction to the field of nonlinear optics that stresses fundamental concepts and that enables the student to go on to perform independent research in this field. This book covers the areas of nonlinear optics, quantum optics, quantum electronics, laser physics, electrooptics, and modern optics

  2. Physical optics

    International Nuclear Information System (INIS)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-01

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  3. Physical optics

    Energy Technology Data Exchange (ETDEWEB)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-15

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  4. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  5. Electron optics

    CERN Document Server

    Grivet, Pierre; Bertein, F; Castaing, R; Gauzit, M; Septier, Albert L

    1972-01-01

    Electron Optics, Second English Edition, Part I: Optics is a 10-chapter book that begins by elucidating the fundamental features and basic techniques of electron optics, as well as the distribution of potential and field in electrostatic lenses. This book then explains the field distribution in magnetic lenses; the optical properties of electrostatic and magnetic lenses; and the similarities and differences between glass optics and electron optics. Subsequent chapters focus on lens defects; some electrostatic lenses and triode guns; and magnetic lens models. The strong focusing lenses and pris

  6. Magneto-optic and electro-optic modulators

    International Nuclear Information System (INIS)

    Hutchinson, D.P.; Ma, C.H.; Price, T.R.; Staats, P.A.; Sluis, K.L.V.

    1982-01-01

    An important aspect of the Faraday rotation diagnostic for tokamak plasma measurement has been the development of suitable polarization modulators for submillimeter wavelength. The problems are to obtain high optical transmission and fast modulation frequencies. In ORNL, the authors have developed both a magneto-optic and an electro-optic submillimeter-wave modulators. These devices have been operated at modulation frequency of approximately 100 kHz, and both have high transmission. The original magneto-optic modulator consists of a 3 mm thick by 1.4 cm diameter 2-111 ferrite disk mounted at the center of an air core coil. Recently, a new ferrite modulator has been tested, which allows a much higher modulation frequency than the original device. A laboratory set-up designed to simulate a plasma heterodyne interferometer/polarimeter experiment has been used to determine the modulator characteristics. A mechanical polarization rotor was used to simulate the rotation by plasma. The transmission of the ferrite disk was 80 % at a wavelength of 0.447 mm. The authors have also performed preliminary measurement on an electro-optic modulator first demonstrated by Fetterman at Lincoln Laboratory, U.S. This device is a classical electro-optic modulator using a cryogenically cooled (4.2 K) LiTaO 3 crystal. Experiments are underway to determine the electro-optic properties of the crystal over the temperature range from 4.2 K to 77 K and over the range of wavelength from 0.118 mm to 0.447 mm. (Wakatsuki, Y.)

  7. Atomic optics. The optics of the year 2000?

    International Nuclear Information System (INIS)

    Guzman, Angela M.

    1998-01-01

    In atom optics the roles of light and matter are exchanged with respect to those of conventional optics. Atom optics makes possible the manipulation of atoms with lasers. This review deals with foundations and recent developments on atom optics: laser cooling and trapping, optical lattices, Bose-Einstein Condensation (BEC), and the atom laser. Main features of BEC and theoretical models for generation of a coherent atomic beam are described, indicating the technological challenges involved in their implementation. Special attention is devoted to the model of Guzman et al. perspectives and possible applications are mentioned

  8. Magneto-optic and electro-optic modulators

    International Nuclear Information System (INIS)

    Hutchinson, D.P.; Ma, C.H.; Price, T.R.; Staats, P.A.; Vander Sluis, K.L.

    1982-01-01

    An important aspect of the Faraday rotation diagnostic for tokamak plasma measurements has been the development of suitable polarization modulators for submillimeter wavelengths. The problems are to obtain high optical transmission and fast modulation frequencies. At ORNL we have developed both a magneto-optic and an electro-optic submillimeter-wave modulators. These devices have been operated at modulation frequencies of approximately 100 kHz and both have high transmission

  9. International Symposium on Optics and its Applications (OPTICS-2011)

    Science.gov (United States)

    Bhattacherjee, Aranya B.; Calvo, Maria L.; Kazaryan, Eduard M.; Papoyan, Aram V.; Sarkisyan, Hayk A.

    2012-03-01

    OPTICS Logo PREFACE The papers selected for this volume were reported at the International Symposium 'Optics and its applications' (OPTICS-2011, Yerevan & Ashtarak, Armenia, September 5-9, 2011), http://www.ipr.sci.am/optics2011/. The Symposium was organized by the SPIE Armenian Student Chapter and major Armenian R&D organizations, universities and industrial companies working in the field of basic and applied optics: Institute for Physical Research of the National Academy of Sciences of Armenia, Yerevan State University, Russian-Armenian (Slavonic) University, and LT-PYRKAL Closed Joint Stock Company. OPTICS-2011 was primarily intended to support and promote the involvement of students and young scientists in various fields of modern optics, giving them the possibility to attend invited talks by prominent scientists and to present and discuss their own results. Furthermore, the Symposium allowed foreign participants from 14 countries to become acquainted with the achievements of optical science and technology in Armenia, which became a full member of the International Commission for Optics (ICO) in 2011. To follow this concept, the Symposium sessions were held in various host institutions. The creative and friendly ambience established at OPTICS-2011 promoted further international collaboration in the field and motivated many students to take up research in optics and photonics as a career. This volume of Journal of Physics: Conference Series covers thematic sections of the Symposium (both oral and poster), which represent the main fields of interest in optics for Armenian scientists: quantum optics & information, laser spectroscopy, optical properties of nanostructures, photonics & fiber optics, and optics of liquid crystals. Such wide coverage is consistent with the general scope of the Symposium, allowing all the students involved in optics to present, discuss and publish their recent results, and for those who are making their first steps in science to choose

  10. Optical Computing

    OpenAIRE

    Woods, Damien; Naughton, Thomas J.

    2008-01-01

    We consider optical computers that encode data using images and compute by transforming such images. We give an overview of a number of such optical computing architectures, including descriptions of the type of hardware commonly used in optical computing, as well as some of the computational efficiencies of optical devices. We go on to discuss optical computing from the point of view of computational complexity theory, with the aim of putting some old, and some very recent, re...

  11. Fibre-optic communications

    CERN Document Server

    Lecoy, Pierre

    2010-01-01

    This book describes in a comprehensive manner the components and systems of fiber optic communications and networks. The first section explains the theory of multimode and single-mode fibers, then the technological features, including manufacturing, cabling, and connecting. The second section describes the various components (passive and active optical components, integrated optics, opto-electronic transmitters and receivers, and optical amplifiers) used in fiber optic systems. Finally, the optical transmission system design is explained, and applications to optical networks and fiber optic se

  12. FIBER OPTICS: Fibre optics: Forty years later

    Science.gov (United States)

    Dianov, Evgenii M.

    2010-01-01

    This paper presents a brief overview of the state of the art in fibre optics and its main applications: optical fibre communications, fibre lasers and fibre sensors for various physical property measurements. The future of fibre optics and the status of this important area of the modern technology in Russia are discussed.

  13. Digital optical processing of optical communications: towards an Optical Turing Machine

    Science.gov (United States)

    Touch, Joe; Cao, Yinwen; Ziyadi, Morteza; Almaiman, Ahmed; Mohajerin-Ariaei, Amirhossein; Willner, Alan E.

    2017-01-01

    Optical computing is needed to support Tb/s in-network processing in a way that unifies communication and computation using a single data representation that supports in-transit network packet processing, security, and big data filtering. Support for optical computation of this sort requires leveraging the native properties of optical wave mixing to enable computation and switching for programmability. As a consequence, data must be encoded digitally as phase (M-PSK), semantics-preserving regeneration is the key to high-order computation, and data processing at Tb/s rates requires mixing. Experiments have demonstrated viable approaches to phase squeezing and power restoration. This work led our team to develop the first serial, optical Internet hop-count decrement, and to design and simulate optical circuits for calculating the Internet checksum and multiplexing Internet packets. The current exploration focuses on limited-lookback computational models to reduce the need for permanent storage and hybrid nanophotonic circuits that combine phase-aligned comb sources, non-linear mixing, and switching on the same substrate to avoid the macroscopic effects that hamper benchtop prototypes.

  14. Digital optical processing of optical communications: towards an Optical Turing Machine

    Directory of Open Access Journals (Sweden)

    Touch Joe

    2017-01-01

    Full Text Available Optical computing is needed to support Tb/s in-network processing in a way that unifies communication and computation using a single data representation that supports in-transit network packet processing, security, and big data filtering. Support for optical computation of this sort requires leveraging the native properties of optical wave mixing to enable computation and switching for programmability. As a consequence, data must be encoded digitally as phase (M-PSK, semantics-preserving regeneration is the key to high-order computation, and data processing at Tb/s rates requires mixing. Experiments have demonstrated viable approaches to phase squeezing and power restoration. This work led our team to develop the first serial, optical Internet hop-count decrement, and to design and simulate optical circuits for calculating the Internet checksum and multiplexing Internet packets. The current exploration focuses on limited-lookback computational models to reduce the need for permanent storage and hybrid nanophotonic circuits that combine phase-aligned comb sources, non-linear mixing, and switching on the same substrate to avoid the macroscopic effects that hamper benchtop prototypes.

  15. The extent of intrauterine growth restriction determines the severity of cerebral injury and neurobehavioural deficits in rodents.

    Science.gov (United States)

    Ruff, Crystal A; Faulkner, Stuart D; Rumajogee, Prakasham; Beldick, Stephanie; Foltz, Warren; Corrigan, Jennifer; Basilious, Alfred; Jiang, Shangjun; Thiyagalingam, Shanojan; Yager, Jerome Y; Fehlings, Michael G

    2017-01-01

    Cerebral Palsy (CP) is the most common physical pediatric neurodevelopmental disorder and spastic diplegic injury is its most frequent subtype. CP results in substantial neuromotor and cognitive impairments that have significant socioeconomic impact. Despite this, its underlying pathophysiological mechanisms and etiology remain incompletely understood. Furthermore, there is a need for clinically relevant injury models, which a) reflect the heterogeneity of the condition and b) can be used to evaluate new translational therapies. To address these key knowledge gaps, we characterized a chronic placental insufficiency (PI) model, using bilateral uterine artery ligation (BUAL) of dams. This injury model results in intrauterine growth restriction (IUGR) in pups, and animals recapitulate the human phenotype both in terms of neurobehavioural and anatomical deficits. Effects of BUAL were studied using luxol fast blue (LFB)/hematoxylin & eosin (H&E) staining, immunohistochemistry, quantitative Magnetic Resonance Imaging (MRI), and Catwalk neurobehavioural tests. Neuroanatomical analysis revealed regional ventricular enlargement and corpus callosum thinning in IUGR animals, which was correlated with the extent of growth restriction. Olig2 staining revealed reductions in oligodendrocyte density in white and grey matter structures, including the corpus callosum, optic chiasm, and nucleus accumbens. The caudate nucleus, along with other brain structures such as the optic chiasm, internal capsule, septofimbrial and lateral septal nuclei, exhibited reduced size in animals with IUGR. The size of the pretectal nucleus was reduced only in moderately injured animals. MAG/NF200 staining demonstrated reduced myelination and axonal counts in the corpus callosum of IUGR animals. NeuN staining revealed changes in neuronal density in the hippocampus and in the thickness of hippocampal CA2 and CA3 regions. Diffusion weighted imaging (DWI) revealed regional white and grey matter changes at 3

  16. The extent of intrauterine growth restriction determines the severity of cerebral injury and neurobehavioural deficits in rodents.

    Directory of Open Access Journals (Sweden)

    Crystal A Ruff

    Full Text Available Cerebral Palsy (CP is the most common physical pediatric neurodevelopmental disorder and spastic diplegic injury is its most frequent subtype. CP results in substantial neuromotor and cognitive impairments that have significant socioeconomic impact. Despite this, its underlying pathophysiological mechanisms and etiology remain incompletely understood. Furthermore, there is a need for clinically relevant injury models, which a reflect the heterogeneity of the condition and b can be used to evaluate new translational therapies. To address these key knowledge gaps, we characterized a chronic placental insufficiency (PI model, using bilateral uterine artery ligation (BUAL of dams. This injury model results in intrauterine growth restriction (IUGR in pups, and animals recapitulate the human phenotype both in terms of neurobehavioural and anatomical deficits.Effects of BUAL were studied using luxol fast blue (LFB/hematoxylin & eosin (H&E staining, immunohistochemistry, quantitative Magnetic Resonance Imaging (MRI, and Catwalk neurobehavioural tests.Neuroanatomical analysis revealed regional ventricular enlargement and corpus callosum thinning in IUGR animals, which was correlated with the extent of growth restriction. Olig2 staining revealed reductions in oligodendrocyte density in white and grey matter structures, including the corpus callosum, optic chiasm, and nucleus accumbens. The caudate nucleus, along with other brain structures such as the optic chiasm, internal capsule, septofimbrial and lateral septal nuclei, exhibited reduced size in animals with IUGR. The size of the pretectal nucleus was reduced only in moderately injured animals. MAG/NF200 staining demonstrated reduced myelination and axonal counts in the corpus callosum of IUGR animals. NeuN staining revealed changes in neuronal density in the hippocampus and in the thickness of hippocampal CA2 and CA3 regions. Diffusion weighted imaging (DWI revealed regional white and grey matter

  17. Choreographing Couch and Collimator in Volumetric Modulated Arc Therapy

    International Nuclear Information System (INIS)

    Yang Yingli; Zhang Pengpeng; Happersett, Laura; Xiong Jianping; Yang Jie; Chan, Maria; Beal, Kathryn; Mageras, Gig; Hunt, Margie

    2011-01-01

    Purpose: To design and optimize trajectory-based, noncoplanar subarcs for volumetric modulated arc therapy (VMAT) deliverable on both Varian TrueBEAM system and traditional accelerators; and to investigate their potential advantages for treating central nervous system (CNS) tumors. Methods and Materials: To guide the computerized selection of beam trajectories consisting of simultaneous couch, gantry, and collimator motion, a score function was implemented to estimate the geometric overlap between targets and organs at risk for each couch/gantry angle combination. An initial set of beam orientations is obtained as a function of couch and gantry angle, according to a minimum search of the score function excluding zones of collision. This set is grouped into multiple continuous and extended subarcs subject to mechanical limitations using a hierarchical clustering algorithm. After determination of couch/gantry trajectories, a principal component analysis finds the collimator angle at each beam orientation that minimizes residual target-organ at risk overlaps. An in-house VMAT optimization algorithm determines the optimal multileaf collimator position and monitor units for control points within each subarc. A retrospective study of 10 CNS patients compares the proposed method of VMAT trajectory with dynamic gantry, leaves, couch, and collimator motion (Tra-VMAT); a standard noncoplanar VMAT with no couch/collimator motion within subarcs (Std-VMAT); and noncoplanar intensity-modulated radiotherapy (IMRT) plans that were clinically used. Results: Tra-VMAT provided improved target dose conformality and lowered maximum dose to brainstem, optic nerves, and chiasm by 7.7%, 1.1%, 2.3%, and 1.7%, respectively, compared with Std-VMAT. Tra-VMAT provided higher planning target volume minimum dose and reduced maximum dose to chiasm, optic nerves, and cochlea by 6.2%, 1.3%, 6.3%, and 8.4%, respectively, and reduced cochlea mean dose by 8.7%, compared with IMRT. Tra-VMAT averaged

  18. Realization of an optical interferometer based on holographic optics ...

    Indian Academy of Sciences (India)

    The paper describes a simple and cost effective method for the realization of an optical interferometer based on holographic optics, which use minimal bulk optical components. The optical arrangement in the proposed method involves a very simple alignment procedure and inexpensive holographic recording material is ...

  19. Controlling lightwave in Riemann space by merging geometrical optics with transformation optics.

    Science.gov (United States)

    Liu, Yichao; Sun, Fei; He, Sailing

    2018-01-11

    In geometrical optical design, we only need to choose a suitable combination of lenses, prims, and mirrors to design an optical path. It is a simple and classic method for engineers. However, people cannot design fantastical optical devices such as invisibility cloaks, optical wormholes, etc. by geometrical optics. Transformation optics has paved the way for these complicated designs. However, controlling the propagation of light by transformation optics is not a direct design process like geometrical optics. In this study, a novel mixed method for optical design is proposed which has both the simplicity of classic geometrical optics and the flexibility of transformation optics. This mixed method overcomes the limitations of classic optical design; at the same time, it gives intuitive guidance for optical design by transformation optics. Three novel optical devices with fantastic functions have been designed using this mixed method, including asymmetrical transmissions, bidirectional focusing, and bidirectional cloaking. These optical devices cannot be implemented by classic optics alone and are also too complicated to be designed by pure transformation optics. Numerical simulations based on both the ray tracing method and full-wave simulation method are carried out to verify the performance of these three optical devices.

  20. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  1. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  2. Infantile neuroaxonal dystrophy: neuroradiological studies in 11 patients

    Energy Technology Data Exchange (ETDEWEB)

    Farina, L.; Bruzzone, M.G.; D`Incerti, L.; Savoiardo, M. [Department of Neuroradiology, Istituto Nazionale Neurologico C. Besta, Milan (Italy); Nardocci, N.; Zorzi, G. [Department of Child Neurology, Istituto Nazionale Neurologico C. Besta, Milan (Italy); Verga, L.; Morbin, M. [Department of Neuropathology, Istituto Nazionale, Neurologico C. Besta, Milan (Italy)

    1999-05-01

    We report the imaging findings in 11 patients with infantile neuroaxonal dystrophy. Ten patients underwent 15 MRI examinations; one patient had only CT. Of the ten patients who underwent MRI, eight had cerebellar atrophy and mildly increased signal from the cerebellar cortex on T2-weighted images. With T2 weighting there was slightly increased signal from the dentate nuclei in two patients and from the posterior periventricular white matter in three. We saw four patients with a thin optic chiasm. The only two brothers in the series had markedly low signal from the globus pallidus and substantia nigra on 1.5 T T2-weighted images, as seen in Hallervorden-Spatz disease (HSD). Abnormalities of the globus pallidus may be related to a protracted course of the disease. However, an overlap with HSD should be considered. (orig.) With 3 figs., 1 tab., 28 refs.

  3. Optical Observations of X-ray Bright, Optically Normal Galaxies

    Science.gov (United States)

    Sadun, Alberto C.; Aryan, N. S.; Ghosh, K. K.

    2007-05-01

    X-ray bright, optically normal galaxies (XBONGs) are galaxies that seem to have normal spectra and morphology, but are relatively bright x-ray sources. The large ratio of the x-ray to optical emission suggests that some activity, similar to that of active galactic nuclei (AGN), is occurring. Since the galaxies do not show any obvious sign of nuclear activity in their optical spectra, one possible explanation is that these galaxies do not have an optically thick accretion disk at small radii, as previously assumed. Previous data for NGC 7626 classifies it as an XBONG, and so we are studying optical features of this galaxy in order to determine better its features. After confirming an x-ray jet, we are now comparing this to optical features that we have found, including warped dust lanes and a possible optical jet.

  4. All-optical microwave signal processing based on optical phase modulation

    Science.gov (United States)

    Zeng, Fei

    This thesis presents a theoretical and experimental study of optical phase modulation and its applications in all-optical microwave signal processing, which include all-optical microwave filtering, all-optical microwave mixing, optical code-division multiple-access (CDMA) coding, and ultrawideband (UWB) signal generation. All-optical microwave signal processing can be considered as the use of opto-electronic devices and systems to process microwave signals in the optical domain, which provides several significant advantages such as low loss, low dispersion, light weight, high time bandwidth products, and immunity to electromagnetic interference. In conventional approaches, the intensity of an optical carrier is modulated by a microwave signal based on direct modulation or external modulation. The intensity-modulated optical signal is then fed to a photonic circuit or system to achieve specific signal processing functionalities. The microwave signal being processed is usually obtained based on direct detection, i.e., an opto-electronic conversion by use of a photodiode. In this thesis, the research efforts are focused on the optical phase modulation and its applications in all-optical microwave signal processing. To avoid using coherent detection which is complicated and costly, simple and effective phase modulation to intensity modulation (PM-IM) conversion schemes are pursued. Based on a theoretical study of optical phase modulation, two approaches to achieving PM-IM conversions are proposed. In the first approach, the use of chromatic dispersion induced by a dispersive device to alter the phase relationships among the sidebands and the optical carrier of a phase-modulated optical signal to realize PM-IM conversion is investigated. In the second approach, instead of using a dispersive device, the PM-IM conversion is realized based on optical frequency discrimination implemented using an optical filter. We show that the proposed PM-IM conversion schemes can be

  5. Optical interconnects

    CERN Document Server

    Chen, Ray T

    2006-01-01

    This book describes fully embedded board level optical interconnect in detail including the fabrication of the thin-film VCSEL array, its characterization, thermal management, the fabrication of optical interconnection layer, and the integration of devices on a flexible waveguide film. All the optical components are buried within electrical PCB layers in a fully embedded board level optical interconnect. Therefore, we can save foot prints on the top real estate of the PCB and relieve packaging difficulty reduced by separating fabrication processes. To realize fully embedded board level optical

  6. Optics for dummies

    CERN Document Server

    Duree, Galen C

    2011-01-01

    The easy way to shed light on Optics In general terms, optics is the science of light. More specifically, optics is a branch of physics that describes the behavior and properties of light?including visible, infrared, and ultraviolet?and the interaction of light with matter. Optics For Dummies gives you an approachable introduction to optical science, methods, and applications. You'll get plain-English explanations of the nature of light and optical effects; reflection, refraction, and diffraction; color dispersion; optical devices, industrial, medical, and military applicatio

  7. Atmospheric free-space coherent optical communications with adaptive optics

    Science.gov (United States)

    Ting, Chueh; Zhang, Chengyu; Yang, Zikai

    2017-02-01

    Free-space coherent optical communications have a potential application to offer last mile bottleneck solution in future local area networks (LAN) because of their information carrier, information security and license-free status. Coherent optical communication systems using orthogonal frequency division multiplexing (OFDM) digital modulation are successfully demonstrated in a long-haul tens Giga bits via optical fiber, but they are not yet available in free space due to atmospheric turbulence-induced channel fading. Adaptive optics is recognized as a promising technology to mitigate the effects of atmospheric turbulence in free-space optics. In this paper, a free-space coherent optical communication system using an OFDM digital modulation scheme and adaptive optics (FSO OFDM AO) is proposed, a Gamma-Gamma distribution statistical channel fading model for the FSO OFDM AO system is examined, and FSO OFDM AO system performance is evaluated in terms of bit error rate (BER) versus various propagation distances.

  8. Monolithically integrated quantum dot optical modulator with semiconductor optical amplifier for thousand and original band optical communication

    Science.gov (United States)

    Yamamoto, Naokatsu; Akahane, Kouichi; Umezawa, Toshimasa; Matsumoto, Atsushi; Kawanishi, Tetsuya

    2016-04-01

    A monolithically integrated quantum dot (QD) optical gain modulator (OGM) with a QD semiconductor optical amplifier (SOA) was successfully developed with T-band (1.0 µm waveband) and O-band (1.3 µm waveband) QD optical gain materials for Gbps-order, high-speed optical data generation. The insertion loss due to coupling between the device and the optical fiber was effectively compensated for by the SOA section. It was also confirmed that the monolithic QD-OGM/SOA device enabled >4.8 Gbps optical data generation with a clear eye opening in the T-band. Furthermore, we successfully demonstrated error-free 4.8 Gbps optical data transmissions in each of the six wavelength channels over a 10-km-long photonic crystal fiber using the monolithic QD-OGM/SOA device in multiple O-band wavelength channels, which were generated by the single QD gain chip. These results suggest that the monolithic QD-OGM/SOA device will be advantageous in ultra-broadband optical frequency systems that utilize the T+O-band for short- and medium-range optical communications.

  9. Integrating optical, mechanical, and test software (with applications to freeform optics)

    Science.gov (United States)

    Genberg, Victor; Michels, Gregory; Myer, Brian

    2017-10-01

    Optical systems must perform under environmental conditions including thermal and mechanical loading. To predict the performance in the field, integrated analysis combining optical and mechanical software is required. Freeform and conformal optics offer many new opportunities for optical design. The unconventional geometries can lead to unconventional, and therefore unintuitive, mechanical behavior. Finite element (FE) analysis offers the ability to predict the deformations of freeform optics under various environments and load conditions. To understand the impact on optical performance, the deformations must be brought into optical analysis codes. This paper discusses several issues related to the integrated optomechanical analysis of freeform optics.

  10. Metamaterials for light rays: ray optics without wave-optical analog in the ray-optics limit

    International Nuclear Information System (INIS)

    Hamilton, Alasdair C; Courtial, Johannes

    2009-01-01

    Volumes of sub-wavelength electromagnetic elements can act like homogeneous materials: metamaterials. In analogy, sheets of optical elements such as prisms can act ray-optically like homogeneous sheet materials. In this sense, such sheets can be considered to be metamaterials for light rays (METATOYs). METATOYs realize new and unusual transformations of the directions of transmitted light rays. We study here, in the ray-optics and scalar-wave limits, the wave-optical analog of such transformations, and we show that such an analog does not always exist. Perhaps, this is the reason why many of the ray-optical possibilities offered by METATOYs have never before been considered.

  11. Wave-optics modeling of the optical-transport line for passive optical stochastic cooling

    Science.gov (United States)

    Andorf, M. B.; Lebedev, V. A.; Piot, P.; Ruan, J.

    2018-03-01

    Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsystemcritical to the OSC scheme is the focusing optics used to image radiation from the upstream "pickup" undulator to the downstream "kicker" undulator. In this paper, we present simulation results using wave-optics calculation carried out with the SYNCHROTRON RADIATION WORKSHOP (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrable Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.

  12. Photonic layer security in fiber-optic networks and optical OFDM transmission

    Science.gov (United States)

    Wang, Zhenxing

    Currently the Internet is experiencing an explosive growth in the world. Such growth leads to an increased data transmission rate demand in fiber-optical networks. Optical orthogonal frequency multiplexing (OFDM) is considered as a promising solution to achieve data rate beyond 100Gb/s per wavelength channel. In the meanwhile, because of extensive data transmission and sharing, data security has become an important problem and receives considerable attention in current research literature. This thesis focuses on data security issues at the physical layer of optical networks involving code-division multiple access (CDMA) systems and steganography methods. The thesis also covers several implementation issues in optical OFDM transmission. Optical CDMA is regarded as a good candidate to provide photonic layer security in multi-access channels. In this thesis we provide a systematic analysis of the security performance of incoherent optical CDMA codes. Based on the analysis, we proposed and experimentally demonstrated several methods to improve the security performance of the optical CDMA systems, such as applying all-optical encryption, and code hopping using nonlinear wavelength conversion. Moreover, we demonstrate that the use of wireless CDMA codes in optical systems can enhance the security in one single-user end-to-end optical channel. Optical steganography is another method to provide photonic data security and involves hiding the existence of data transmissions. In the thesis, we demonstrate that an optical steganography channel can exist in phase modulated public channels as well as traditional on-off-keying (OOK) modulated channels, without data synchronization. We also demonstrate an optical steganography system with enhanced security by utilizing temporal phase modulation techniques. Additionally, as one type of an overlay channel, the optical steganography technology can carry the sensor data collected by wireless sensor network on top of public optical

  13. Fluidic optics

    Science.gov (United States)

    Whitesides, George M.; Tang, Sindy K. Y.

    2006-09-01

    Fluidic optics is a new class of optical system with real-time tunability and reconfigurability enabled by the introduction of fluidic components into the optical path. We describe the design, fabrication, operation of a number of fluidic optical systems, and focus on three devices, liquid-core/liquid-cladding (L2) waveguides, microfluidic dye lasers, and diffraction gratings based on flowing, crystalline lattices of bubbles, to demonstrate the integration of microfluidics and optics. We fabricate these devices in poly(dimethylsiloxane) (PDMS) with soft-lithographic techniques. They are simple to construct, and readily integrable with microanalytical or lab-on-a-chip systems.

  14. Atom optics

    International Nuclear Information System (INIS)

    Balykin, V. I.; Jhe, W.

    1999-01-01

    Atom optics, in analogy to neutron and electron optics, deals with the realization of as a traditional elements, such as lenes, mirrors, beam splitters and atom interferometers, as well as a new 'dissipative' elements such as a slower and a cooler, which have no analogy in an another types of optics. Atom optics made the development of atom interferometer with high sensitivity for measurement of acceleration and rotational possible. The practical interest in atom optics lies in the opportunities to create atom microprobe with atom-size resolution and minimum damage of investigated objects. (Cho, G. S.)

  15. Tunable laser optics

    CERN Document Server

    Duarte, FJ

    2015-01-01

    This Second Edition of a bestselling book describes the optics and optical principles needed to build lasers. It also highlights the optics instrumentation necessary to characterize laser emissions and focuses on laser-based optical instrumentation. The book emphasizes practical and utilitarian aspects of relevant optics including the essential theory. This revised, expanded, and improved edition contains new material on tunable lasers and discusses relevant topics in quantum optics.

  16. Optical interference coatings for optics and photonics [Invited].

    Science.gov (United States)

    Lee, Cheng-Chung

    2013-01-01

    Optical interference coatings play as an important role in the progress in optics and photonics. In this article we give a minireview of the evolution of optical interference coatings from the theory, the design, to the manufacture. Some interesting but challenging topics for the future are also discussed.

  17. Ray-optics analysis of inhomogeneous optically anisotropic media

    NARCIS (Netherlands)

    Sluijter, M.

    2010-01-01

    When the optical behavior of light in a medium depends on the direction in which light is traveling, the medium is called optically anisotropic. Light is an electromagnetic wave and in this thesis, we discuss the electromagnetic theory on optical anisotropy. We do this with the assumption that the

  18. Wolfram syndrome: a clinicopathologic correlation.

    Science.gov (United States)

    Hilson, Justin B; Merchant, Saumil N; Adams, Joe C; Joseph, Jeffrey T

    2009-09-01

    Wolfram syndrome or DIDMOAD (diabetes insipidus, diabetes mellitus, optic atrophy and deafness) is a neurodegenerative disorder characterized by diabetes mellitus and optic atrophy as well as diabetes insipidus and deafness in many cases. We report the post-mortem neuropathologic findings of a patient with Wolfram syndrome and correlate them with his clinical presentation. In the hypothalamus, neurons in the paraventricular and supraoptic nuclei were markedly decreased and minimal neurohypophyseal tissue remained in the pituitary. The pontine base and inferior olivary nucleus showed gross shrinkage and neuron loss, while the cerebellum was relatively unaffected. The visual system had moderate to marked loss of retinal ganglion neurons, commensurate loss of myelinated axons in the optic nerve, chiasm and tract, and neuron loss in the lateral geniculate nucleus but preservation of the primary visual cortex. The patient's inner ear showed loss of the organ of Corti in the basal turn of the cochleae and mild focal atrophy of the stria vascularis. These findings correlated well with the patient's high-frequency hearing loss. The pathologic findings correlated closely with the patient's clinical symptoms and further support the concept of Wolfram syndrome as a neurodegenerative disorder. Our findings extend prior neuropathologic reports of Wolfram syndrome by providing contributions to our understanding of eye, inner ear and olivopontine pathology in this disease.

  19. Highly Reliable PON Optical Splitters for Optical Access Networks in Outside Environments

    Science.gov (United States)

    Watanabe, Hiroshi; Araki, Noriyuki; Fujimoto, Hisashi

    Broadband optical access services are spreading throughout the world, and the number of fiber to the home (FTTH) subscribers is increasing rapidly. Telecom operators are constructing passive optical networks (PONs) to provide optical access services. Externally installed optical splitters for PONs are very important passive devices in optical access networks, and they must provide satisfactory performance as outdoor plant over long periods. Therefore, we calculate the failure rate of optical access networks and assign a failure rate to the optical splitters in optical access networks. The maximum cumulative failure rate of 1 × 8 optical splitters was calculated as 0.025 for an optical access fiber length of 2.1km and a 20-year operating lifetime. We examined planar lightwave circuit (PLC) type optical splitters for use as outside plant in terms of their optical characteristics and environmental reliability. We confirmed that PLC type optical splitters have sufficient optical performance for a PON splitter and sufficient reliability as outside plant in accordance with ITU-T standard values. We estimated the lifetimes of three kinds of PLC type optical splitters by using accelerated aging tests. The estimated failure rate of these splitters installed in optical access networks was below the target value for the cumulative failure rate, and we confirmed that they have sufficient reliability to maintain the quality of the network service. We developed 1 × 8 optical splitter modules with plug and socket type optical connectors and optical fiber cords for optical aerial closures designed for use as outside plant. These technologies make it easy to install optical splitters in an aerial optical closure. The optical splitter modules have sufficient optical performance levels for PONs because the insertion loss at the commercially used wavelengths of 1.31 and 1.55µm is less than the criterion established by ITU-T Recommendation G.671 for optical splitters. We performed a

  20. Optical XOR gate

    Science.gov (United States)

    Vawter, G. Allen

    2013-11-12

    An optical XOR gate is formed as a photonic integrated circuit (PIC) from two sets of optical waveguide devices on a substrate, with each set of the optical waveguide devices including an electroabsorption modulator electrically connected in series with a waveguide photodetector. The optical XOR gate utilizes two digital optical inputs to generate an XOR function digital optical output. The optical XOR gate can be formed from III-V compound semiconductor layers which are epitaxially deposited on a III-V compound semiconductor substrate, and operates at a wavelength in the range of 0.8-2.0 .mu.m.

  1. Fiber optic connector

    Science.gov (United States)

    Rajic, Slobodan; Muhs, Jeffrey D.

    1996-01-01

    A fiber optic connector and method for connecting composite materials within which optical fibers are imbedded. The fiber optic connector includes a capillary tube for receiving optical fibers at opposing ends. The method involves inserting a first optical fiber into the capillary tube and imbedding the unit in the end of a softened composite material. The capillary tube is injected with a coupling medium which subsequently solidifies. The composite material is machined to a desired configuration. An external optical fiber is then inserted into the capillary tube after fluidizing the coupling medium, whereby the optical fibers are coupled.

  2. Wave-Optics Modeling of the Optical-Transport Line for Passive Optical Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andorf, M. B. [NICADD, DeKalb; Lebedev, V. A. [Fermilab; Piot, P. [Fermilab; Ruan, J. [Fermilab

    2018-03-01

    Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsytem critical to the OSC scheme is the focusing optics used to image radiation from the upstream "pickup" undulator to the downstream "kicker" undulator. In this paper, we present simulation results using wave-optics calculation carried out with the {\\sc Synchrotron Radiation Workshop} (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrable Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.

  3. Two mode optical fiber in space optics communication

    Science.gov (United States)

    Hampl, Martin

    2017-11-01

    In our contribution we propose to use of a two-mode optical fiber as a primary source in a transmitting optical head instead of the laser diode. The distribution of the optical intensity and the complex degree of the coherence on the output aperture of the lens that is irradiated by a step-index weakly guiding optical fiber is investigated. In our treatment we take into account weakly guided modes with polarization corrections to the propagation constant and unified theory of second order coherence and polarization of electromagnetic beams.

  4. Stiffness of RBC optical confinement affected by optical clearing

    Science.gov (United States)

    Grishin, Oleg V.; Fedosov, Ivan V.; Tuchin, Valery V.

    2017-03-01

    In vivo optical trapping is a novel applied direction of an optical manipulation, which enables one to noninvasive measurement of mechanical properties of cells and tissues in living animals directly. But an application area of this direction is limited because strong scattering of many biological tissues. An optical clearing enables one to decrease the scattering and therefore increase a depth of light penetration, decrease a distortion of light beam, improve a resolution in imaging applications. Now novel methods had appeared for a measurement an optical clearing degree at a cellular level. But these methods aren't applicable in vivo. In this paper we present novel measurement method of estimate of the optical clearing, which are based on a measurement of optical trap stiffness. Our method may be applicable in vivo.

  5. Quantum Optics

    CERN Document Server

    Walls, D F

    2007-01-01

    Quantum Optics gives a comprehensive coverage of developments in quantum optics over the past years. In the early chapters the formalism of quantum optics is elucidated and the main techniques are introduced. These are applied in the later chapters to problems such as squeezed states of light, resonance fluorescence, laser theory, quantum theory of four-wave mixing, quantum non-demolition measurements, Bell's inequalities, and atom optics. Experimental results are used to illustrate the theory throughout. This yields the most comprehensive and up-to-date coverage of experiment and theory in quantum optics in any textbook. More than 40 exercises helps readers test their understanding and provide practice in quantitative problem solving.

  6. Optical-domain Compensation for Coupling between Optical Fiber Conjugate Vortex Modes

    DEFF Research Database (Denmark)

    Lyubopytov, Vladimir S.; Tatarczak, Anna; Lu, Xiaofeng

    2016-01-01

    We demonstrate for the first time optical-domain compensation for coupling between conjugate vortex modes in optical fibers. We introduce a novel method for reconstructing the complex propagation matrix of the optical fiber with straightforward implementation.......We demonstrate for the first time optical-domain compensation for coupling between conjugate vortex modes in optical fibers. We introduce a novel method for reconstructing the complex propagation matrix of the optical fiber with straightforward implementation....

  7. Wideband optical vector network analyzer based on optical single-sideband modulation and optical frequency comb.

    Science.gov (United States)

    Xue, Min; Pan, Shilong; He, Chao; Guo, Ronghui; Zhao, Yongjiu

    2013-11-15

    A novel approach to increase the measurement range of the optical vector network analyzer (OVNA) based on optical single-sideband (OSSB) modulation is proposed and experimentally demonstrated. In the proposed system, each comb line in an optical frequency comb (OFC) is selected by an optical filter and used as the optical carrier for the OSSB-based OVNA. The frequency responses of an optical device-under-test (ODUT) are thus measured channel by channel. Because the comb lines in the OFC have fixed frequency spacing, by fitting the responses measured in all channels together, the magnitude and phase responses of the ODUT can be accurately achieved in a large range. A proof-of-concept experiment is performed. A measurement range of 105 GHz and a resolution of 1 MHz is achieved when a five-comb-line OFC with a frequency spacing of 20 GHz is applied to measure the magnitude and phase responses of a fiber Bragg grating.

  8. Overexpression of Pax6 results in microphthalmia, retinal dysplasia and defective retinal ganglion cell axon guidance

    Directory of Open Access Journals (Sweden)

    Jeffery Glen

    2008-05-01

    contralateral optic tracts at the optic chiasm vary differently with gene dosage. Increasing dosage increases the proportion projecting ipsilaterally regardless of the size of the total projection. Conclusion Pax6 overexpression does not obviously impair the initial formation of the eye and its major cell-types but prevents normal development of the retina from about E14.5, leading eventually to severe retinal degeneration in postnatal life. This sequence is different to that underlying microphthalmia in Pax6+/- heterozygotes, which is due primarily to defects in the initial stages of lens formation. Before the onset of severe retinal dysplasia, Pax6 overexpression causes defects of retinal axons, preventing their normal growth and navigation through the optic chiasm.

  9. Transnasal Endoscopic Optic Nerve Decompression in Post Traumatic Optic Neuropathy.

    Science.gov (United States)

    Gupta, Devang; Gadodia, Monica

    2018-03-01

    To quantify the successful outcome in patients following optic nerve decompression in post traumatic unilateral optic neuropathy in form of improvement in visual acuity. A prospective study was carried out over a period of 5 years (January 2011 to June 2016) at civil hospital Ahmedabad. Total 20 patients were selected with optic neuropathy including patients with direct and indirect trauma to unilateral optic nerve, not responding to conservative management, leading to optic neuropathy and subsequent impairment in vision and blindness. Decompression was done via Transnasal-Ethmo-sphenoidal route and outcome was assessed in form of post-operative visual acuity improvement at 1 month, 6 months and 1 year follow up. After surgical decompression complete recovery of visual acuity was achieved in 16 (80%) patients and partial recovery in 4 (20%). Endoscopic transnasal approach is beneficial in traumatic optic neuropathy not responding to steroid therapy and can prevent permanent disability if earlier intervention is done prior to irreversible damage to the nerve. Endoscopic optic nerve surgery can decompress the traumatic and oedematous optic nerve with proper exposure of orbital apex and optic canal without any major intracranial, intraorbital and transnasal complications.

  10. Peptide Integrated Optics.

    Science.gov (United States)

    Handelman, Amir; Lapshina, Nadezda; Apter, Boris; Rosenman, Gil

    2018-02-01

    Bio-nanophotonics is a wide field in which advanced optical materials, biomedicine, fundamental optics, and nanotechnology are combined and result in the development of biomedical optical chips. Silk fibers or synthetic bioabsorbable polymers are the main light-guiding components. In this work, an advanced concept of integrated bio-optics is proposed, which is based on bioinspired peptide optical materials exhibiting wide optical transparency, nonlinear and electrooptical properties, and effective passive and active waveguiding. Developed new technology combining bottom-up controlled deposition of peptide planar wafers of a large area and top-down focus ion beam lithography provides direct fabrication of peptide optical integrated circuits. Finding a deep modification of peptide optical properties by reconformation of biological secondary structure from native phase to β-sheet architecture is followed by the appearance of visible fluorescence and unexpected transition from a native passive optical waveguiding to an active one. Original biocompatibility, switchable regimes of waveguiding, and multifunctional nonlinear optical properties make these new peptide planar optical materials attractive for application in emerging technology of lab-on-biochips, combining biomedical photonic and electronic circuits toward medical diagnosis, light-activated therapy, and health monitoring. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A study on Optical Labelling Techniques for All-Optical Networks

    DEFF Research Database (Denmark)

    Holm-Nielsen, Pablo Villanueva

    2005-01-01

    Optical switching has been proposed as an effective solution to overcoming the potential electronic bottleneck in all-optical network nodes carrying IP over WDM. The solution builds on the use of optical labelling as a mean to route packets or bursts of packets through the network. In addition...... of an intermediate wavelength between label erasure and label insertion. The above mentioned functionalities are assembled in whole network systems experiments that validates the different labelling schemes with respect to transmission, wavelength conversion, label swapping and retransmission. Optical labelling...... and specially the orthogonal schemes for optical labelling, are thus shown to be an effective solution to all-optical networks....

  12. Viscous optical clearing agent for in vivo optical imaging

    Science.gov (United States)

    Deng, Zijian; Jing, Lijia; Wu, Ning; lv, Pengyu; Jiang, Xiaoyun; Ren, Qiushi; Li, Changhui

    2014-07-01

    By allowing more photons to reach deeper tissue, the optical clearing agent (OCA) has gained increasing attention in various optical imaging modalities. However, commonly used OCAs have high fluidity, limiting their applications in in vivo studies with oblique, uneven, or moving surfaces. In this work, we reported an OCA with high viscosity. We measured the properties of this viscous OCA, and tested its successful performances in the imaging of a living animal's skin with two optical imaging modalities: photoacoustic microscopy and optical coherence tomography. Our results demonstrated that the viscous OCA has a great potential in the study of different turbid tissues using various optical imaging modalities.

  13. ADVANTAGES OF DIFFRACTIVE OPTICAL ELEMENTS APPLICATION IN SIMPLE OPTICAL IMAGING SYSTEMS

    Directory of Open Access Journals (Sweden)

    N. D. Zoric

    2015-01-01

    Full Text Available The paper deals with the influence of diffractive optical elements on the optical aberrations. The correction of optical aberrations was investigated in the simple optical systems with one and two lenses (singlet and doublet. The advantages of diffractive optical elements are their ability to generate arbitrary complex wave fronts from a piece of optical material that is essentially flat. The optical systems consisting of the standard surfaces were designed and optimized by using the same starting points. Further, the diffractive and aspheric surfaces were introduced into the developed systems. The resulting hybrid systems were optimized. To compare the complicity of the development of narrow field systems and wide field optical systems, the optimization has been done separately for these two types of the instruments. The optical systems were designed by using special Optical Design Software. Тhe characteristics of designed diffractive surfaces were controlled in Software DIFSYS 2.30. Due to the application of diffractive optical elements the longitudinal chromatic aberration was 5 times reduced for the narrow field systems. The absolute value of Seidel coefficient related to the spherical aberration was reduced in the range of 0.03. Considering that diffractive optical elements have the known disadvantages, like possible parasitic diffraction orders and probable decrease of the transmission, we also developed and analyzed the optical systems with combined aspheric and diffractive surfaces. A combination of the aspheric and diffractive surfaces in the optical disk system of the disk reading lens, gave cutting down of the longitudinal color aberrations almost 15 times on-axis, comparing to the lens consisting of the aspherical and standard surfaces. All of the designed diffractive optical elements possess the parameters within the fabrication limits.

  14. Fiber optic based optical tomography sensor for monitoring plasma uniformity

    International Nuclear Information System (INIS)

    Benck, Eric C.; Etemadi, Kasra

    2001-01-01

    A new type of fiber optic based optical tomography sensor has been developed for in situ monitoring of plasma uniformity. Optical tomography inverts optical emission measurements into the actual plasma distribution without assuming radial symmetry. The new sensor is designed to operate with only two small windows and acquire the necessary data in less than a second. Optical tomography is being tested on an ICP-GEC RF plasma source. Variations in plasma uniformity are measured as a function of different plasma conditions

  15. Optical trapping of a spherically symmetric sphere in the ray-optics regime: a model for optical tweezers upon cells

    International Nuclear Information System (INIS)

    Chang Yiren; Hsu Long; Chi Sien

    2006-01-01

    Since their invention in 1986, optical tweezers have become a popular manipulation and force measurement tool in cellular and molecular biology. However, until recently there has not been a sophisticated model for optical tweezers on trapping cells in the ray-optics regime. We present a model for optical tweezers to calculate the optical force upon a spherically symmetric multilayer sphere representing a common biological cell. A numerical simulation of this model shows that not only is the magnitude of the optical force upon a Chinese hamster ovary cell significantly three times smaller than that upon a polystyrene bead of the same size, but the distribution of the optical force upon a cell is also much different from that upon a uniform particle, and there is a 30% difference in the optical trapping stiffness of these two cases. Furthermore, under a small variant condition for the refractive indices of any adjacent layers of the sphere, this model provides a simple approximation to calculate the optical force and the stiffness of an optical tweezers system

  16. Applied optics

    International Nuclear Information System (INIS)

    Orszag, A.; Antonetti, A.

    1988-01-01

    The 1988 progress report, of the Applied Optics laboratory, of the (Polytechnic School, France), is presented. The optical fiber activities are focused on the development of an optical gyrometer, containing a resonance cavity. The following domains are included, in the research program: the infrared laser physics, the laser sources, the semiconductor physics, the multiple-photon ionization and the nonlinear optics. Investigations on the biomedical, the biological and biophysical domains are carried out. The published papers and the congress communications are listed [fr

  17. Optic Nerve Pit

    Science.gov (United States)

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Optic Nerve Pit What is optic nerve pit? An optic nerve pit is a ... may be seen in both eyes. How is optic pit diagnosed? If the pit is not affecting ...

  18. Ultrafast all-optical signal processing using semiconductor optical amplifiers

    NARCIS (Netherlands)

    Li, Z.

    2007-01-01

    As the bit rate of one wavelength channel and the number of channels keep increasing in the telecommunication networks thanks to the advancement of optical transmission technologies, switching is experiencing the transition from the electrical domain to the optical domain. All-optical signal

  19. Fibre Optic Gyroscope Developments Using Integrated Optic Components

    Science.gov (United States)

    Minford, W. J.; DePaula, R. M.

    1988-09-01

    The sensing of rotation using counterpropagating optical beams in a fiber loop (the SAGNAC effect) has gone through extensive developments and demonstrations since first proved feasible by Vali and Shorthilll in 1976. The interferometric fiber gyroscope minimum configuration2 which uses a common input-output port and single-mode filter was developed to provide the extreme high stability necessary to reach the sensitivities at low rotation rates attainable with current state-of-the-art detectors. The simplicity and performance of this configuration has led to its acceptance and wide-spread use. In order to increase the mechanical stability of this system, all single-mode fiber components are employed and a further advancement to integrated optics has enabled most of the optical functions to be placed on a single mass-producible substrate. Recent improvements in the components (eg polarization maintaining fiber and low coherence sources) have further enhanced the performance of the minimum configuration gyro. This presentation focused on the impact of LiNbO3 integrated optic components on gyroscope developments. The use of Ti-indiffused LiNbO3 waveguide optical circuits in interferometric fiber optic gyroscopes has taken two directions: to utilize only the phase modulator, or to combine many of the minimum configuration optical functions on the electro-optic substrate. The high-bandwidth phase modulator is the driving force for using LiNbO3 waveguide devices. This device allows both biasing the gyro for maximum sensitivity and closing the loop via frequency shifting, for example, thus increasing the dynamic range of the gyro and the linearity of the scale factor. Efforts to implement most of the minimum configuration optical functions onto a single LiNbO3 substrate have been led by Thomson CSF.3 They have demonstrated an interferometric gyroscope with excellent performance using a LiNbO3 optical circuit containing a Y-splitter, phase modulator, and surface

  20. Fiber-Optic Pyrometer with Optically Powered Switch for Temperature Measurements.

    Science.gov (United States)

    Vázquez, Carmen; Pérez-Prieto, Sandra; López-Cardona, Juan D; Tapetado, Alberto; Blanco, Enrique; Moreno-López, Jorge; Montero, David S; Lallana, Pedro C

    2018-02-06

    We report the experimental results on a new infrared fiber-optic pyrometer for very localized and high-speed temperature measurements ranging from 170 to 530 °C using low-noise photodetectors and high-gain transimpedance amplifiers with a single gain mode in the whole temperature range. We also report a shutter based on an optical fiber switch which is optically powered to provide a reference signal in an optical fiber pyrometer measuring from 200 to 550 °C. The tests show the potential of remotely powering via optical means a 300 mW power-hungry optical switch at a distance of 100 m, avoiding any electromagnetic interference close to the measuring point.

  1. Fiber-Optic Pyrometer with Optically Powered Switch for Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Carmen Vázquez

    2018-02-01

    Full Text Available We report the experimental results on a new infrared fiber-optic pyrometer for very localized and high-speed temperature measurements ranging from 170 to 530 °C using low-noise photodetectors and high-gain transimpedance amplifiers with a single gain mode in the whole temperature range. We also report a shutter based on an optical fiber switch which is optically powered to provide a reference signal in an optical fiber pyrometer measuring from 200 to 550 °C. The tests show the potential of remotely powering via optical means a 300 mW power-hungry optical switch at a distance of 100 m, avoiding any electromagnetic interference close to the measuring point.

  2. Problems of Aero-optics and Adaptive Optical Systems: Analytical Review

    Directory of Open Access Journals (Sweden)

    Yu. I. Shanin

    2017-01-01

    Full Text Available The analytical review gives the basic concepts of the aero-optics problem arising from the radiation propagation in the region of the boundary layers of a laser installation carrier aircraft. Estimates the radiation wave front distortions at its propagation in the near and far field. Presents main calculation approaches and methods to solve the gas-dynamic and optical problems in propagating laser radiation. Conducts a detailed analysis of the flows and their generating optical aberrations introduced by the aircraft turret (a projection platform of the on-board laser. Considers the effect of various factors (shock wave, difference in wall and flow temperatures on the flow pattern and the optical aberrations. Provides research data on the aero-optics obtained in the flying laboratory directly while in flight. Briefly considers the experimental research methods, diagnostic equipment, and synthesis of results while studying the aero-optics problem. Discusses some methods for mitigating the aerodynamic effects on the light propagation under flight conditions. Presents data about the passive, active, and hybrid effects on the flow in the boundary layers in order to reduce aberrations through improving the flow aerodynamics.The paper considers operation of adaptive optical systems under conditions of aero-optical distortions. Presents the study results concerning the reduction of the aero-optics effect on the characteristics of radiation in far field. Gives some research results regarding the effect on the efficiency of the adaptive system of a laser beam jitter and a time delay in the feedback signal transmission, which occur under application conditions. Provides data on adaptive correction of aero-optical wave fronts of radiation. Considers some application aspects in control systems of the on-board adaptive optics of adaptive filtration as a way to improve the efficiency of adaptive optical systems. The project in mind is to use obtained results

  3. Optical computing, optical memory, and SBIRs at Foster-Miller

    Science.gov (United States)

    Domash, Lawrence H.

    1994-03-01

    A desktop design and manufacturing system for binary diffractive elements, MacBEEP, was developed with the optical researcher in mind. Optical processing systems for specialized tasks such as cellular automation computation and fractal measurement were constructed. A new family of switchable holograms has enabled several applications for control of laser beams in optical memories. New spatial light modulators and optical logic elements have been demonstrated based on a more manufacturable semiconductor technology. Novel synthetic and polymeric nonlinear materials for optical storage are under development in an integrated memory architecture. SBIR programs enable creative contributions from smaller companies, both product oriented and technology oriented, and support advances that might not otherwise be developed.

  4. All-Optical Regeneration System for Optical Wavelength Division Multiplexed Communication Systems

    DEFF Research Database (Denmark)

    2014-01-01

    The invention relates to an all-optical regeneration system for regeneration of optical wavelength division multiplexed WDM data signals in an optical WDM communication system. The system comprises a WDM-to-Optical time domain multiplexing OTDM, WDM-to-OTDM, converter, capable of converting....... The system additionally comprises an OTDM-to-WDM converter for converting the output OTDM data signal to an output WDM data signal. An input of the all-optical regenerator unit is in optical communication with an output of the WDM-to-OTDM converter, and an output of the all-optical regenerator unit...... an input WDM data signal comprising multiple wavelength channels into an input OTDM data signal comprising multiple time multiplexed time channels. The system further comprises an all-optical regenerator unit being configured for regenerating the input OTDM data signal into an output OTDM data signal...

  5. Generation of optical vortices in an integrated optical circuit

    Science.gov (United States)

    Tudor, Rebeca; Kusko, Mihai; Kusko, Cristian

    2017-09-01

    In this work, the generation of optical vortices in an optical integrated circuit is numerically demonstrated. The optical vortices with topological charge m = ±1 are obtained by the coherent superposition of the first order modes present in a waveguide with a rectangular cross section, where the phase delay between these two propagating modes is Δφ = ±π/2. The optical integrated circuit consists of an input waveguide continued with a y-splitter. The left and the right arms of the splitter form two coupling regions K1 and K2 with a multimode output waveguide. In each coupling region, the fundamental modes present in the arms of the splitter are selectively coupled into the output waveguide horizontal and vertical first order modes, respectively. We showed by employing the beam propagation method simulations that the fine tuning of the geometrical parameters of the optical circuit makes possible the generation of optical vortices in both transverse electric (TE) and transverse magnetic (TM) modes. Also, we demonstrated that by placing a thermo-optical element on one of the y-splitter arms, it is possible to switch the topological charge of the generated vortex from m = 1 to m = -1.

  6. Integrated optical transceiver with electronically controlled optical beamsteering

    Science.gov (United States)

    Davids, Paul; DeRose, Christopher; Tauke-Pedretti, Anna

    2017-08-22

    A beam-steering optical transceiver is provided. The transceiver includes one or more modules, each comprising an antenna chip and a control chip bonded to the antenna chip. Each antenna chip has a feeder waveguide, a plurality of row waveguides that tap off from the feeder waveguide, and a plurality of metallic nanoantenna elements arranged in a two-dimensional array of rows and columns such that each row overlies one of the row waveguides. Each antenna chip also includes a plurality of independently addressable thermo-optical phase shifters, each configured to produce a thermo-optical phase shift in a respective row. Each antenna chip also has, for each row, a row-wise heating circuit configured to produce a respective thermo-optic phase shift at each nanoantenna element along its row. The control chip includes controllable current sources for the independently addressable thermo-optical phase shifters and the row-wise heating circuits.

  7. Integrated Optical Circuit Engineering For Optical Fiber Gyrocopes

    Science.gov (United States)

    Bristow, Julian P.; We, Albert C.; Keur, M.; Lukas, Greg; Ott, Daniel M...; Sriram, S.

    1988-03-01

    Fiber optic gyroscopes are of interest for low-cost, high performance rotation sensors. Integrated optical implementations of the processing optics offer the hope of mass-production, and associated cost reductions. The development of a suitable integrated optical system has been reported by other authors at a wavelength of 850nm [1]. Despite strong technical advantages at 1.3μm wavelength [2], no results have yet appeared. This wavelength is preferred for telecommunications applications applications, thus significantly reduced fiber costs may be realized. Lithium niobate is relatively immune from the photorefractive effect at this wavelength, whereas it is not at at 850nm [3].

  8. Optical pulse generation using fiber lasers and integrated optics

    International Nuclear Information System (INIS)

    Wilcox, R.B.; Browning, D.F.; Burkhart, S.C.; VanWonterghem, B.W.

    1995-01-01

    We have demonstrated an optical pulse forming system using fiber and integrated optics, and have designed a multiple-output system for a proposed fusion laser facility. Our approach is an advancement over previous designs for fusion lasers, and an unusual application of fiber lasers and integrated optics

  9. Optical computing.

    Science.gov (United States)

    Stroke, G. W.

    1972-01-01

    Applications of the optical computer include an approach for increasing the sharpness of images obtained from the most powerful electron microscopes and fingerprint/credit card identification. The information-handling capability of the various optical computing processes is very great. Modern synthetic-aperture radars scan upward of 100,000 resolvable elements per second. Fields which have assumed major importance on the basis of optical computing principles are optical image deblurring, coherent side-looking synthetic-aperture radar, and correlative pattern recognition. Some examples of the most dramatic image deblurring results are shown.

  10. MEMS optical sensor

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an all-optical sensor utilizing effective index modulation of a waveguide and detection of a wavelength shift of reflected light and a force sensing system accommodating said optical sensor. One embodiment of the invention relates to a sensor system comprising...... at least one multimode light source, one or more optical sensors comprising a multimode sensor optical waveguide accommodating a distributed Bragg reflector, at least one transmitting optical waveguide for guiding light from said at least one light source to said one or more multimode sensor optical...... waveguides, a detector for measuring light reflected from said Bragg reflector in said one or more multimode sensor optical waveguides, and a data processor adapted for analyzing variations in the Bragg wavelength of at least one higher order mode of the reflected light....

  11. Optical biosensors.

    Science.gov (United States)

    Damborský, Pavel; Švitel, Juraj; Katrlík, Jaroslav

    2016-06-30

    Optical biosensors represent the most common type of biosensor. Here we provide a brief classification, a description of underlying principles of operation and their bioanalytical applications. The main focus is placed on the most widely used optical biosensors which are surface plasmon resonance (SPR)-based biosensors including SPR imaging and localized SPR. In addition, other optical biosensor systems are described, such as evanescent wave fluorescence and bioluminescent optical fibre biosensors, as well as interferometric, ellipsometric and reflectometric interference spectroscopy and surface-enhanced Raman scattering biosensors. The optical biosensors discussed here allow the sensitive and selective detection of a wide range of analytes including viruses, toxins, drugs, antibodies, tumour biomarkers and tumour cells. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  12. Optical Pattern Recognition

    Science.gov (United States)

    Yu, Francis T. S.; Jutamulia, Suganda

    2008-10-01

    Contributors; Preface; 1. Pattern recognition with optics Francis T. S. Yu and Don A. Gregory; 2. Hybrid neural networks for nonlinear pattern recognition Taiwei Lu; 3. Wavelets, optics, and pattern recognition Yao Li and Yunglong Sheng; 4. Applications of the fractional Fourier transform to optical pattern recognition David Mendlovic, Zeev Zalesky and Haldum M. Oxaktas; 5. Optical implementation of mathematical morphology Tien-Hsin Chao; 6. Nonlinear optical correlators with improved discrimination capability for object location and recognition Leonid P. Yaroslavsky; 7. Distortion-invariant quadratic filters Gregory Gheen; 8. Composite filter synthesis as applied to pattern recognition Shizhou Yin and Guowen Lu; 9. Iterative procedures in electro-optical pattern recognition Joseph Shamir; 10. Optoelectronic hybrid system for three-dimensional object pattern recognition Guoguang Mu, Mingzhe Lu and Ying Sun; 11. Applications of photrefractive devices in optical pattern recognition Ziangyang Yang; 12. Optical pattern recognition with microlasers Eung-Gi Paek; 13. Optical properties and applications of bacteriorhodopsin Q. Wang Song and Yu-He Zhang; 14. Liquid-crystal spatial light modulators Aris Tanone and Suganda Jutamulia; 15. Representations of fully complex functions on real-time spatial light modulators Robert W. Cohn and Laurence G. Hassbrook; Index.

  13. Optical network democratization.

    Science.gov (United States)

    Nejabati, Reza; Peng, Shuping; Simeonidou, Dimitra

    2016-03-06

    The current Internet infrastructure is not able to support independent evolution and innovation at physical and network layer functionalities, protocols and services, while at same time supporting the increasing bandwidth demands of evolving and heterogeneous applications. This paper addresses this problem by proposing a completely democratized optical network infrastructure. It introduces the novel concepts of the optical white box and bare metal optical switch as key technology enablers for democratizing optical networks. These are programmable optical switches whose hardware is loosely connected internally and is completely separated from their control software. To alleviate their complexity, a multi-dimensional abstraction mechanism using software-defined network technology is proposed. It creates a universal model of the proposed switches without exposing their technological details. It also enables a conventional network programmer to develop network applications for control of the optical network without specific technical knowledge of the physical layer. Furthermore, a novel optical network virtualization mechanism is proposed, enabling the composition and operation of multiple coexisting and application-specific virtual optical networks sharing the same physical infrastructure. Finally, the optical white box and the abstraction mechanism are experimentally evaluated, while the virtualization mechanism is evaluated with simulation. © 2016 The Author(s).

  14. Acousto-optic interaction in polyimide coated optical fibers with flexural waves

    OpenAIRE

    ALCUSA-SÁEZ, E. P.; Díez, A.; Rivera-Pérez, E.; Margulis, W.; Norin, L.; Andrés, M. V.

    2017-01-01

    Acousto-optic coupling in polyimide-coated single-mode optical fibers using flexural elastic waves is demonstrated. The effect of the polyimide coating on the acousto-optic interaction process is analyzed in detailed. Theoretical and experimental results are in good agreement. Although the elastic attenuation is significant, we show that acousto-optic coupling can be produced with a reasonably good efficiency. To our knowledge, it is the first experimental demonstration of acousto-optic coupl...

  15. All-optical OXC transition strategy from WDM optical network to elastic optical network.

    Science.gov (United States)

    Chen, Xin; Li, Juhao; Guo, Bingli; Zhu, Paikun; Tang, Ruizhi; Chen, Zhangyuan; He, Yongqi

    2016-02-22

    Elastic optical network (EON) has been proposed recently as a spectrum-efficient optical layer to adapt to rapidly-increasing traffic demands instead of current deployed wavelength-division-multiplexing (WDM) optical network. In contrast with conventional WDM optical cross-connect (OXCs) based on wavelength selective switches (WSSs), the EON OXCs are based on spectrum selective switches (SSSs) which are much more expensive than WSSs, especially for large-scale switching architectures. So the transition cost from WDM OXCs to EON OXCs is a major obstacle to realizing EON. In this paper, we propose and experimentally demonstrate a transition OXC (TOXC) structure based on 2-stage cascading switching architectures, which make full use of available WSSs in current deployed WDM OXCs to reduce number and port count of required SSSs. Moreover, we propose a contention-aware spectrum allocation (CASA) scheme for EON built with the proposed TOXCs. We show by simulation that the TOXCs reduce the network capital expenditure transiting from WDM optical network to EON about 50%, with a minor traffic blocking performance degradation and about 10% accommodated traffic number detriment compared with all-SSS EON OXC architectures.

  16. Piezo-optic and elasto-optic properties of monoclinic triglycine sulfate crystals.

    Science.gov (United States)

    Mytsyk, Bogdan; Demyanyshyn, Natalya; Erba, Alessandro; Shut, Viktor; Mozzharov, Sergey; Kost, Yaroslav; Mys, Oksana; Vlokh, Rostyslav

    2017-12-01

    For the first time, to the best of our knowledge, we have experimentally determined all of the components of the piezo-optic tensor for monoclinic crystals. This has been implemented on a specific example of triglycine sulfate crystals. Based on the results obtained, the complete elasto-optic tensor has been calculated. Acousto-optic figures of merit (AOFMs) have been estimated for the case of acousto-optic interaction occurring in the principal planes of the optical indicatrix ellipsoid and for geometries in which the highest elasto-optic coefficients are involved as effective parameters. It has been found that the highest AOFM value is equal to 6.8×10 -15   s 3 /kg for the case of isotropic acousto-optic interaction with quasi-longitudinal acoustic waves in the principal planes. This AOFM is higher than the corresponding values typical for canonic acousto-optic materials, which are transparent in the deep ultraviolet spectral range.

  17. Optics equations for aero-optical analysis

    Science.gov (United States)

    Sutton, George W.; Pond, John E.

    2011-05-01

    Aero-optical effects occur around moving air vehicles and impact passive imaging or active systems. The air flow around the vehicle is compressed, and often there is a turbulent shear and/or boundary layer both of which cause variations in the index of refraction. Examples of these are reconnaissance aircraft, the Stratospheric Observatory for Infrared Optics (SOFIA), and optically homing hypersonic interceptors. In other applications, a laser beam can be formed within the vehicle, and projected outward and focused on an object. These include the Airborne Laser Laboratory, Airborne Laser and the Airborne Tactical Laser. There are many compressible fluid mechanics computer programs that can predict the air density distribution of the surrounding flow field including density fluctuations in turbulent shear and/or boundary layers. It is necessary for the physical optics to be used to predict the properties of the ensuing image plane intensity distribution, whether passive or active. These include the time-averaged image blur circle and instantaneous realizations. (Ray tracing is a poor approximation that gives erroneous results for small aberrations.)

  18. Automated optical assembly

    Science.gov (United States)

    Bala, John L.

    1995-08-01

    Automation and polymer science represent fundamental new technologies which can be directed toward realizing the goal of establishing a domestic, world-class, commercial optics business. Use of innovative optical designs using precision polymer optics will enable the US to play a vital role in the next generation of commercial optical products. The increased cost savings inherent in the utilization of optical-grade polymers outweighs almost every advantage of using glass for high volume situations. Optical designers must gain experience with combined refractive/diffractive designs and broaden their knowledge base regarding polymer technology beyond a cursory intellectual exercise. Implementation of a fully automated assembly system, combined with utilization of polymer optics, constitutes the type of integrated manufacturing process which will enable the US to successfully compete with the low-cost labor employed in the Far East, as well as to produce an equivalent product.

  19. Optical system design

    CERN Document Server

    Fischer, Robert F

    2008-01-01

    Honed for more than 20 years in an SPIE professional course taught by renowned optical systems designer Robert E. Fischer, Optical System Design, Second Edition brings you the latest cutting-edge design techniques and more than 400 detailed diagrams that clearly illustrate every major procedure in optical design. This thoroughly updated resource helps you work better and faster with computer-aided optical design techniques, diffractive optics, and the latest applications, including digital imaging, telecommunications, and machine vision. No need for complex, unnecessary mathematical derivations-instead, you get hundreds of examples that break the techniques down into understandable steps. For twenty-first century optical design without the mystery, the authoritative Optical Systems Design, Second Edition features: Computer-aided design use explained through sample problems Case studies of third-millennium applications in digital imaging, sensors, lasers, machine vision, and more New chapters on optomechanic...

  20. A constrained tracking algorithm to optimize plug patterns in multiple isocenter Gamma Knife radiosurgery planning

    International Nuclear Information System (INIS)

    Li Kaile; Ma Lijun

    2005-01-01

    We developed a source blocking optimization algorithm for Gamma Knife radiosurgery, which is based on tracking individual source contributions to arbitrarily shaped target and critical structure volumes. A scalar objective function and a direct search algorithm were used to produce near real-time calculation results. The algorithm allows the user to set and vary the total number of plugs for each shot to limit the total beam-on time. We implemented and tested the algorithm for several multiple-isocenter Gamma Knife cases. It was found that the use of limited number of plugs significantly lowered the integral dose to the critical structures such as an optical chiasm in pituitary adenoma cases. The main effect of the source blocking is the faster dose falloff in the junction area between the target and the critical structure. In summary, we demonstrated a useful source-plugging algorithm for improving complex multi-isocenter Gamma Knife treatment planning cases

  1. Transsphenoidal pituitary resection with intraoperative MR guidance: preliminary results

    Science.gov (United States)

    Pergolizzi, Richard S., Jr.; Schwartz, Richard B.; Hsu, Liangge; Wong, Terence Z.; Black, Peter M.; Martin, Claudia; Jolesz, Ferenc A.

    1999-05-01

    The use of intraoperative MR image guidance has the potential to improve the precision, extent and safety of transsphenoidal pituitary resections. At Brigham and Women's Hospital, an open-bore configuration 0.5T MR system (SIGNA SP, GE Medical Systems, Milwaukee, WI) has been used to provide image guidance for nine transsphenoidal pituitary adenoma resections. The intraoperative MR system allowed the radiologist to direct the surgeon toward the sella turcica successfully while avoiding the cavernous sinus, optic chiasm and other sensitive structures. Imaging performed during the surgery monitored the extent of resection and allowed for removal of tumor beyond the surgeon's view in five cases. Dynamic MR imaging was used to distinguish residual tumor from normal gland and postoperative changes permitting more precise tumor localization. A heme-sensitive long TE gradient echo sequence was used to evaluate for the presence of hemorrhagic debris. All patients tolerated the procedure well without significant complications.

  2. Pituitary macroadenomas: reviews of 60 cases; Revisao de 60 casos de macroadenomas hipofisarios

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Alair Augusto S.M.D. dos; Fontes, Cristina Asvolinsque P.; Magnago, Marcelo [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moreira, Denise Madeira [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Radiologia; Andreiuolo, Pedro Angelo [Hospital Santa Cruz/Beneficencia Portuguesa, Niteroi, RJ (Brazil). Servico de Radiologia; Oliveira, Fernando Barros de; Teixeira, Ricardo Tostes D.; Correa, Saul Orlando C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Biofisica Carlos Chagas Filho. Curso de Pos-graduacao Medica

    2000-12-01

    We reviewed 60 cases of patients with pituitary macroadenomas who were submitted to magnetic resonance imaging evaluations at private institutions in Niteroi and Rio de Janeiro, Brazil. The aim of this study was to demonstrate the advantages of magnetic resonance imaging in the diagnosis and follow-up of these patients. Macroprolactinomas were the most prevalent tumors. We also observed four growth-hormone (GH) secreting macroadenomas with clinical signs of acromegaly, and one GH- and prolactin-secreting macroadenoma. Seven patients presented pituitary apoplexy and hyperintense signal on T1-W images before contrast medium (gadolinium) administration suggestive of intratumoral bleeding. The follow-up of 15 cases demonstrated a reduction in the size of the tumor after surgery, clinical treatment or radiotherapy. Magnetic resonance imaging is important for the study of pituitary macroadenomas, particularly before surgery, as it shows the involvement of adjacent structures, specially the cavernous sinus, optic chiasm and pituitary stalk compression. (author)

  3. Pituitary macroadenomas: reviews of 60 cases

    International Nuclear Information System (INIS)

    Santos, Alair Augusto S.M.D. dos; Fontes, Cristina Asvolinsque P.; Magnago, Marcelo; Moreira, Denise Madeira; Andreiuolo, Pedro Angelo; Oliveira, Fernando Barros de; Teixeira, Ricardo Tostes D.; Correa, Saul Orlando C.

    2000-01-01

    We reviewed 60 cases of patients with pituitary macroadenomas who were submitted to magnetic resonance imaging evaluations at private institutions in Niteroi and Rio de Janeiro, Brazil. The aim of this study was to demonstrate the advantages of magnetic resonance imaging in the diagnosis and follow-up of these patients. Macroprolactinomas were the most prevalent tumors. We also observed four growth-hormone (GH) secreting macroadenomas with clinical signs of acromegaly, and one GH- and prolactin-secreting macroadenoma. Seven patients presented pituitary apoplexy and hyperintense signal on T1-W images before contrast medium (gadolinium) administration suggestive of intratumoral bleeding. The follow-up of 15 cases demonstrated a reduction in the size of the tumor after surgery, clinical treatment or radiotherapy. Magnetic resonance imaging is important for the study of pituitary macroadenomas, particularly before surgery, as it shows the involvement of adjacent structures, specially the cavernous sinus, optic chiasm and pituitary stalk compression. (author)

  4. Intelligent Optical Systems Using Adaptive Optics

    Science.gov (United States)

    Clark, Natalie

    2012-01-01

    Until recently, the phrase adaptive optics generally conjured images of large deformable mirrors being integrated into telescopes to compensate for atmospheric turbulence. However, the development of smaller, cheaper devices has sparked interest for other aerospace and commercial applications. Variable focal length lenses, liquid crystal spatial light modulators, tunable filters, phase compensators, polarization compensation, and deformable mirrors are becoming increasingly useful for other imaging applications including guidance navigation and control (GNC), coronagraphs, foveated imaging, situational awareness, autonomous rendezvous and docking, non-mechanical zoom, phase diversity, and enhanced multi-spectral imaging. The active components presented here allow flexibility in the optical design, increasing performance. In addition, the intelligent optical systems presented offer advantages in size and weight and radiation tolerance.

  5. Applications of Nano-optics.

    Science.gov (United States)

    Zhou, Changhe; Fainman, Yeshaiahu; Sheng, Yunlong

    2011-11-01

    As nanoscale fabrication techniques advance, nano-optics continues to offer enabling solutions to numerous practical applications for information optics. This Applied Optics feature issue focuses on the Application of Nano-optics. © 2011 Optical Society of America

  6. Optic disc oedema

    DEFF Research Database (Denmark)

    Nielsen, Marianne Kromann; Hamann, Steffen

    2014-01-01

    Optic disc oedema describes the nonspecific, localized swelling of the optic nerve head regardless of aetiology. Therefore, differentiating among the various aetiologies depends on a thorough history and knowledge of the clinical characteristics of the underlying conditions. Papilloedema strictly...... refers to optic disc oedema as a consequence of elevated intracranial pressure. It is usually a bilateral condition and visual function is preserved until late. Optic disc oedema caused by an anterior optic neuropathy is usually unilateral and accompanied by the loss of visual function....

  7. All-optical NRZ-to-RZ data format conversion with optically injected laser diode or semiconductor optical amplifier

    Science.gov (United States)

    Lin, Gong-Ru; Chang, Yung-Cheng; Yu, Kun-Chieh

    2006-09-01

    By injecting the optical NRZ data into a Fabry-Perot laser diode (FPLD) synchronously modulated at below threshold condition or a semiconductor optical amplifier (SOA) gain-depleted with a backward injected clock stream, the all-optical non-return to zero (NRZ) to return-to-zero (RZ) format conversion of a STM-64 date-stream for synchronous digital hierarchy (SDH) or an OC-192 data stream for synchronous optical network (SONET) in high-speed fiber-optic communication link can be performed. Without the assistance of any complicated RF electronic circuitry, the output RZ data-stream at bit rate of up to 10 Gbit/s is successfully transformed in the optically NRZ injection-locked FPLD, in which the incoming NRZ data induces gain-switching of the FPLD without DC driving current or at below threshold condition. A power penalty of 1.2 dB is measured after NRZ-to-RZ transformation in the FPLD. Alternatively, the all-optical 10Gbits/s NRZ-to-RZ format conversion can also be demonstrated in a semiconductor optical amplifier under a backward dark-optical-comb injection with its duty-cycle 70%, which is obtained by reshaping from the received data clock at 10 GHz. The incoming optical NRZ data-stream is transformed into a pulsed RZ data-stream with its duty-cycle, rms timing jitter, and conversion gain of 15%, 4ps, and 3dB, respectively. In contrast to the FPLD, the SOA based NRZ-to-RZ converter exhibits an enhanced extinction ratio from 7 to 13 dB, and BER of 10 -13 at -18.5 dBm. In particular, the power penalty of the received RZ data-stream has greatly improved by 5 dB as compared to that obtained from FPLD.

  8. Optical metrology for analysis of lobster-eye x-ray optics

    International Nuclear Information System (INIS)

    Irving, Thomas H.K.; Peele, Andrew G.; Nugent, Keith A.

    2003-01-01

    A new method that uses optical microscopy to determine the physical structure of lobster-eye x-ray optics is described. This approach offers the ability to predict x-ray performance without having to take an x-ray measurement. An overlapping series of images of the entrance and exit faces of an optic are obtained and examined by purpose-built software. A 24-parameter description of each channel is obtained from which a quantitative analysis of all the major optic defects, except surface roughness, is performed. Results for a planar lobster-eye optic are used to illustrate this technique and discuss its abilities as well as directions for future enhancements

  9. All-optically integrated photoacoustic and optical coherence tomography: A review

    Directory of Open Access Journals (Sweden)

    Wei Qiao

    2017-07-01

    Full Text Available All-optically integrated photoacoustic (PA and optical coherence tomography (OCT dual-mode imaging technology that could offer comprehensive pathological information for accurate diagnosis in clinic has gradually become a promising imaging technology in the aspect of biomedical imaging during the recent years. This review refers to the technology aspects of all-optical PA detection and system evolution of optically integrated PA and OCT, including Michelson interferometer dual-mode imaging system, Fabry–Perot (FP interferometer dual-mode imaging system and Mach–Zehnder interferometer dual-mode imaging system. It is believed that the optically integrated PA and OCT has great potential applications in biomedical imaging.

  10. Thermal/structural/optical integrated design for optical sensor mounted on unmanned aerial vehicle

    Science.gov (United States)

    Zhang, Gaopeng; Yang, Hongtao; Mei, Chao; Wu, Dengshan; Shi, Kui

    2016-01-01

    With the rapid development of science and technology and the promotion of many local wars in the world, altitude optical sensor mounted on unmanned aerial vehicle is more widely applied in the airborne remote sensing, measurement and detection. In order to obtain high quality image of the aero optical remote sensor, it is important to analysis its thermal-optical performance on the condition of high speed and high altitude. Especially for the key imaging assembly, such as optical window, the temperature variation and temperature gradient can result in defocus and aberrations in optical system, which will lead to the poor quality image. In order to improve the optical performance of a high speed aerial camera optical window, the thermal/structural/optical integrated design method is developed. Firstly, the flight environment of optical window is analyzed. Based on the theory of aerodynamics and heat transfer, the convection heat transfer coefficient is calculated. The temperature distributing of optical window is simulated by the finite element analysis software. The maximum difference in temperature of the inside and outside of optical window is obtained. Then the deformation of optical window under the boundary condition of the maximum difference in temperature is calculated. The optical window surface deformation is fitted in Zernike polynomial as the interface, the calculated Zernike fitting coefficients is brought in and analyzed by CodeV Optical Software. At last, the transfer function diagrams of the optical system on temperature field are comparatively analyzed. By comparing and analyzing the result, it can be obtained that the optical path difference caused by thermal deformation of the optical window is 138.2 nm, which is under PV ≤1 4λ . The above study can be used as an important reference for other optical window designs.

  11. Optic nerve oxygenation

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Pedersen, Daniella Bach; Jensen, Peter Koch

    2005-01-01

    The oxygen tension of the optic nerve is regulated by the intraocular pressure and systemic blood pressure, the resistance in the blood vessels and oxygen consumption of the tissue. The oxygen tension is autoregulated and moderate changes in intraocular pressure or blood pressure do not affect...... the optic nerve oxygen tension. If the intraocular pressure is increased above 40 mmHg or the ocular perfusion pressure decreased below 50 mmHg the autoregulation is overwhelmed and the optic nerve becomes hypoxic. A disturbance in oxidative metabolism in the cytochromes of the optic nerve can be seen...... at similar levels of perfusion pressure. The levels of perfusion pressure that lead to optic nerve hypoxia in the laboratory correspond remarkably well to the levels that increase the risk of glaucomatous optic nerve atrophy in human glaucoma patients. The risk for progressive optic nerve atrophy in human...

  12. Nonlinear optical systems

    CERN Document Server

    Lugiato, Luigi; Brambilla, Massimo

    2015-01-01

    Guiding graduate students and researchers through the complex world of laser physics and nonlinear optics, this book provides an in-depth exploration of the dynamics of lasers and other relevant optical systems, under the umbrella of a unitary spatio-temporal vision. Adopting a balanced approach, the book covers traditional as well as special topics in laser physics, quantum electronics and nonlinear optics, treating them from the viewpoint of nonlinear dynamical systems. These include laser emission, frequency generation, solitons, optically bistable systems, pulsations and chaos and optical pattern formation. It also provides a coherent and up-to-date treatment of the hierarchy of nonlinear optical models and of the rich variety of phenomena they describe, helping readers to understand the limits of validity of each model and the connections among the phenomena. It is ideal for graduate students and researchers in nonlinear optics, quantum electronics, laser physics and photonics.

  13. Fiber-optical accelerometers based on polymer optical fiber Bragg gratings

    DEFF Research Database (Denmark)

    Yuan, Scott Wu; Stefani, Alessio; Bang, Ole

    2010-01-01

    Fiber-optical accelerometers based on polymer optical fiber Bragg gratings (FBGs) are reported. We have written 3mm FBGs for 1550nm operation, characterized their temperature and strain response, and tested their performance in a prototype accelerometer.......Fiber-optical accelerometers based on polymer optical fiber Bragg gratings (FBGs) are reported. We have written 3mm FBGs for 1550nm operation, characterized their temperature and strain response, and tested their performance in a prototype accelerometer....

  14. A multi-ring optical packet and circuit integrated network with optical buffering.

    Science.gov (United States)

    Furukawa, Hideaki; Shinada, Satoshi; Miyazawa, Takaya; Harai, Hiroaki; Kawasaki, Wataru; Saito, Tatsuhiko; Matsunaga, Koji; Toyozumi, Tatuya; Wada, Naoya

    2012-12-17

    We newly developed a 3 × 3 integrated optical packet and circuit switch-node. Optical buffers and burst-mode erbium-doped fiber amplifiers with the gain flatness are installed in the 3 × 3 switch-node. The optical buffer can prevent packet collisions and decrease packet loss. We constructed a multi-ring optical packet and circuit integrated network testbed connecting two single-ring networks and a client network by the 3 × 3 switch-node. For the first time, we demonstrated 244 km fiber transmission and 5-node hopping of multiplexed 14-wavelength 10 Gbps optical paths and 100 Gbps optical packets encapsulating 10 Gigabit Ethernet frames on the testbed. Error-free (frame error rate optical packets of various packet lengths. In addition, successful avoidance of packet collisions by optical buffers was confirmed.

  15. Neutron optical potentials

    International Nuclear Information System (INIS)

    Wilmore, D.; Hodgson, P.E.

    1976-01-01

    The purpose of this paper is to provide a guide to the use of optical model computer programs to analyse and calculate neutron data. After a brief discussion of the physical basis of the optical model a survey is given of the most widely used optical model and Hauser-Feshbach computer programs. The range of applicability and reliability of the major optical potentials proposed is assessed by comparison with available experimental data and some observations and suggestions are made for the optimum choice of optical potentials for given purposes of neutron data calculations. (author)

  16. Optical limiting properties of optically active phthalocyanine derivatives

    Science.gov (United States)

    Wang, Peng; Zhang, Shuang; Wu, Peiji; Ye, Cheng; Liu, Hongwei; Xi, Fu

    2001-06-01

    The optical limiting properties of four optically active phthalocyanine derivatives in chloroform solutions and epoxy resin thin plates were measured at 532 nm with 10 ns pulses. The excited state absorption cross-section σex and refractive-index cross-section σr were determined with the Z-scan technique. These chromophores possess larger σex than the ground state absorption cross-section σ0, indicating that they are the potential materials for reverse saturable absorption (RSA). The negative σr values of these chromophores add to the thermal contribution, producing a larger defocusing effect, which may be helpful in further enhancing their optical limiting performance. The optical limiting responses of the thin plate samples are stronger than those of the chloroform solutions.

  17. All optical OFDM transmission for passive optical networks

    Science.gov (United States)

    Kachare, Nitin; Ashik T., J.; Bai, K. Kalyani; Kumar, D. Sriram

    2017-06-01

    This paper demonstrates the idea of data transmission at a very higher rate (Tbits/s) through optical fibers in a passive optical network using the most efficient data transmission technique widely used in wireless communication that is orthogonal frequency division multiplexing. With an increase in internet users, data traffic has also increased significantly and the current dense wavelength division multiplexing (DWDM) systems may not support the next generation passive optical networks (PONs) requirements. The approach discussed in this paper allows to increase the downstream data rate per user and extend the standard single-mode fiber reach for future long-haul applications. All-optical OFDM is a promising solution for terabit per second capable single wavelength transmission, with high spectral efficiency and high tolerance to chromatic dispersion.

  18. Fiber optics in adverse environments

    International Nuclear Information System (INIS)

    Lyous, P.B.

    1982-01-01

    Radiation effects in optical fibers are considered, taking into account recent progress in the investigation of radiation resistant optical fibers, radiation damage in optical fibers, radiation-induced transient absorption in optical fibers, X-ray-induced transient attenuation at low temperatures in polymer clad silica (PCS) fibers, optical fiber composition and radiation hardness, the response of irradiated optical waveguides at low temperatures, and the effect of ionizing radiation on fiber-optic waveguides. Other topics explored are related to environmental effects on components of fiber optic systems, and radiation detection systems using optical fibers. Fiber optic systems in adverse environments are also discussed, giving attention to the survivability of Army fiber optics systems, space application of fiber optics systems, fiber optic wavelength multiplexing for civil aviation applications, a new fiber optic data bus topology, fiber optics for aircraft engine/inlet control, and application of fiber optics in high voltage substations

  19. Optical absorption measurement system

    International Nuclear Information System (INIS)

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  20. Optical computation based on nonlinear total reflectional optical ...

    Indian Academy of Sciences (India)

    Optical computing; beam splitter; optical switch; polarized beams. ... main research direction called quantum information and quantum computation is .... above has several advantages: Firstly, it is easy to be integrated with appropriate.

  1. Emerging Correlation Optics

    DEFF Research Database (Denmark)

    Angelsky, Oleg V.; Gbur, Gregory J.; Polyanskii, Peter

    2012-01-01

    This feature issue of Applied Optics contains a series of selected papers reflecting the state-of-the-art of correlation optics and showing synergetics between the theoretical background and experimental techniques.......This feature issue of Applied Optics contains a series of selected papers reflecting the state-of-the-art of correlation optics and showing synergetics between the theoretical background and experimental techniques....

  2. Fiber Singular Optics

    OpenAIRE

    A. V. Volyar

    2002-01-01

    The present review is devoted to the optical vortex behavior both in free space and optical fibers. The processes of the vortex transformations in perturbed optical fibers are analyzed on the base of the operator of the spin – orbit interaction in order to forecast the possible ways of manufacturing the vortex preserving fibers and their applications in supersensitive optical devices.

  3. Nonlinear Optics and Applications

    Science.gov (United States)

    Abdeldayem, Hossin A. (Editor); Frazier, Donald O. (Editor)

    2007-01-01

    Nonlinear optics is the result of laser beam interaction with materials and started with the advent of lasers in the early 1960s. The field is growing daily and plays a major role in emerging photonic technology. Nonlinear optics play a major role in many of the optical applications such as optical signal processing, optical computers, ultrafast switches, ultra-short pulsed lasers, sensors, laser amplifiers, and many others. This special review volume on Nonlinear Optics and Applications is intended for those who want to be aware of the most recent technology. This book presents a survey of the recent advances of nonlinear optical applications. Emphasis will be on novel devices and materials, switching technology, optical computing, and important experimental results. Recent developments in topics which are of historical interest to researchers, and in the same time of potential use in the fields of all-optical communication and computing technologies, are also included. Additionally, a few new related topics which might provoke discussion are presented. The book includes chapters on nonlinear optics and applications; the nonlinear Schrodinger and associated equations that model spatio-temporal propagation; the supercontinuum light source; wideband ultrashort pulse fiber laser sources; lattice fabrication as well as their linear and nonlinear light guiding properties; the second-order EO effect (Pockels), the third-order (Kerr) and thermo-optical effects in optical waveguides and their applications in optical communication; and, the effect of magnetic field and its role in nonlinear optics, among other chapters.

  4. Cost-Effective Brillouin Optical Time-Domain Analysis Sensor Using a Single Optical Source and Passive Optical Filtering

    Directory of Open Access Journals (Sweden)

    H. Iribas

    2016-01-01

    Full Text Available We present a simplified configuration for distributed Brillouin optical time-domain analysis sensors that aims to reduce the cost of the sensor by reducing the number of components required for the generation of the two optical waves involved in the sensing process. The technique is based on obtaining the pump and probe waves by passive optical filtering of the spectral components generated in a single optical source that is driven by a pulsed RF signal. The optical source is a compact laser with integrated electroabsorption modulator and the optical filters are based on fiber Bragg gratings. Proof-of-concept experiments demonstrate 1 m spatial resolution over a 20 km sensing fiber with a 0.9 MHz precision in the measurement of the Brillouin frequency shift, a performance similar to that of much more complex setups. Furthermore, we discuss the factors limiting the sensor performance, which are basically related to residual spectral components in the filtering process.

  5. Phase-preserved optical elevator.

    Science.gov (United States)

    Luo, Yuan; Zhang, Baile; Han, Tiancheng; Chen, Zhi; Duan, Yubo; Chu, Chia-Wei; Barbastathis, George; Qiu, Cheng Wei

    2013-03-25

    The unique superiority of transformation optics devices designed from coordinate transformation is their capability of recovering both ray trajectory and optical path length in light manipulation. However, very few experiments have been done so far to verify this dual-recovery property from viewpoints of both ray trajectory and optical path length simultaneously. The experimental difficulties arise from the fact that most previous optical transformation optics devices only work at the nano-scale; the lack of intercomparison between data from both optical path length and ray trajectory measurement in these experiments obscured the fact that the ray path was subject to a subwavelength lateral shift that was otherwise not easily perceivable and, instead, was pointed out theoretically [B. Zhang et al. Phys. Rev. Lett. 104, 233903, 2010]. Here, we use a simple macroscopic transformation optics device of phase-preserved optical elevator, which is a typical birefringent optical phenomenon that can virtually lift an optical image by a macroscopic distance, to demonstrate decisively the unique optical path length preservation property of transformation optics. The recovery of ray trajectory is first determined with no lateral shift in the reflected ray. The phase preservation is then verified with incoherent white-light interferometry without ambiguity and phase unwrapping.

  6. Quantitative optical trapping and optical manipulation of micro-sized objects

    Directory of Open Access Journals (Sweden)

    Rania Sayed

    2017-10-01

    Full Text Available An optical tweezers technique is used for ultraprecise micromanipulation to measure positions of micrometer scale objects with a precision down to the nanometer scale. It consists of a high performance research microscope with motorized scanning stage and sensitive position detection system. Up to 10 traps can be used quasi-simultaneously. Non photodamage optical trapping of Escherichia coli (E. coli bacteria cells of 2 µm in length, as an example of motile bacteria, has been shown in this paper. Also, efficient optical trapping and rotation of polystyrene latex particles of 3 µm in diameter have been studied, as an optical handle for the pick and place of other tiny objects. A fast galvoscanner is used to produce multiple optical traps for manipulation of micro-sized objects and optical forces of these trapped objects quantified and measured according to explanation of ray optics regime. The diameter of trapped particle is bigger than the wavelength of the trapping laser light. The force constant (k has been determined in real time from the positional time series recorded from the trapped object that is monitored by a CCD camera through a personal computer.

  7. Small scale optics

    CERN Document Server

    Yupapin, Preecha

    2013-01-01

    The behavior of light in small scale optics or nano/micro optical devices has shown promising results, which can be used for basic and applied research, especially in nanoelectronics. Small Scale Optics presents the use of optical nonlinear behaviors for spins, antennae, and whispering gallery modes within micro/nano devices and circuits, which can be used in many applications. This book proposes a new design for a small scale optical device-a microring resonator device. Most chapters are based on the proposed device, which uses a configuration know as a PANDA ring resonator. Analytical and nu

  8. Progress in optics

    CERN Document Server

    Wolf, Emil

    1977-01-01

    In the thirty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. At the time of inception of this series, the first lasers were only just becoming operational, holography was in its infancy, subjects such as fiber optics, integrated optics and optoelectronics did not exist and quantum optics was the domain of only a few physicists. The term photonics had not yet been coined. Today these fields are flourishing and have become areas of specialisation for many science and engineering students and n

  9. Progress in optics

    CERN Document Server

    Wolf, Emil

    2006-01-01

    In the thirty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. At the time of inception of this series, the first lasers were only just becoming operational, holography was in its infancy, subjects such as fiber optics, integrated optics and optoelectronics did not exist and quantum optics was the domain of only a few physicists. The term photonics had not yet been coined. Today these fields are flourishing and have become areas of specialisation for many science and engineering students and n

  10. A modular optical sensor

    Science.gov (United States)

    Conklin, John Albert

    This dissertation presents the design of a modular, fiber-optic sensor and the results obtained from testing the modular sensor. The modular fiber-optic sensor is constructed in such manner that the sensor diaphragm can be replaced with different configurations to detect numerous physical phenomena. Additionally, different fiber-optic detection systems can be attached to the sensor. Initially, the modular sensor was developed to be used by university of students to investigate realistic optical sensors and detection systems to prepare for advance studies of micro-optical mechanical systems (MOMS). The design accomplishes this by doing two things. First, the design significantly lowers the costs associated with studying optical sensors by modularizing the sensor design. Second, the sensor broadens the number of physical phenomena that students can apply optical sensing techniques to in a fiber optics sensor course. The dissertation is divided into seven chapters covering the historical development of fiber-optic sensors, a theoretical overview of fiber-optic sensors, the design, fabrication, and the testing of the modular sensor developed in the course of this work. Chapter 1 discusses, in detail, how this dissertation is organized and states the purpose of the dissertation. Chapter 2 presents an historical overview of the development of optical fibers, optical pressure sensors, and fibers, optical pressure sensors, and optical microphones. Chapter 3 reviews the theory of multi-fiber optic detection systems, optical microphones, and pressure sensors. Chapter 4 presents the design details of the modular, optical sensor. Chapter 5 delves into how the modular sensor is fabricated and how the detection systems are constructed. Chapter 6 presents the data collected from the microphone and pressure sensor configurations of the modular sensor. Finally, Chapter 7 discusses the data collected and draws conclusions about the design based on the data collected. Chapter 7 also

  11. Lagrangian optics

    CERN Document Server

    Lakshminarayanan, Vasudevan; Thyagarajan, K

    2002-01-01

    Ingeometrical optics, light propagation is analyzed in terms of light rays which define the path of propagation of light energy in the limitofthe optical wavelength tending to zero. Many features oflight propagation can be analyzed in terms ofrays,ofcourse, subtle effects near foci, caustics or turning points would need an analysis based on the wave natureoflight. Allofgeometric optics can be derived from Fermat's principle which is an extremum principle. The counterpart in classical mechanics is of course Hamilton's principle. There is a very close analogy between mechanics ofparticles and optics oflight rays. Much insight (and useful results) can be obtained by analyzing these analogies. Asnoted by H. Goldstein in his book Classical Mechanics (Addison Wesley, Cambridge, MA, 1956), classical mechanics is only a geometrical optics approximation to a wave theory! In this book we begin with Fermat's principle and obtain the Lagrangian and Hamiltonian pictures of ray propagation through various media. Given the ...

  12. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    Science.gov (United States)

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  13. Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context

    International Nuclear Information System (INIS)

    Isambert, Aurelie; Dhermain, Frederic; Bidault, Francois; Commowick, Olivier; Bondiau, Pierre-Yves; Malandain, Gregoire; Lefkopoulos, Dimitri

    2008-01-01

    Background and purpose: Conformal radiation therapy techniques require the delineation of volumes of interest, a time-consuming and operator-dependent task. In this work, we aimed to evaluate the potential interest of an atlas-based automatic segmentation software (ABAS) of brain organs at risk (OAR), when used under our clinical conditions. Materials and methods: Automatic and manual segmentations of the eyes, optic nerves, optic chiasm, pituitary gland, brain stem and cerebellum of 11 patients on T1-weighted magnetic resonance, 3-mm thick slice images were compared using the Dice similarity coefficient (DSC). The sensitivity and specificity of the ABAS were also computed and analysed from a radiotherapy point of view by splitting the ROC (Receiver Operating Characteristic) space into four sub-regions. Results: Automatic segmentation of OAR was achieved in 7-8 min. Excellent agreement was obtained between automatic and manual delineations for organs exceeding 7 cm 3 : the DSC was greater than 0.8. For smaller structures, the DSC was lower than 0.41. Conclusions: These tests demonstrated that this ABAS is a robust and reliable tool for automatic delineation of large structures under clinical conditions in our daily practice, even though the small structures must continue to be delineated manually by an expert

  14. Optical CDMA components requirements

    Science.gov (United States)

    Chan, James K.

    1998-08-01

    Optical CDMA is a complementary multiple access technology to WDMA. Optical CDMA potentially provides a large number of virtual optical channels for IXC, LEC and CLEC or supports a large number of high-speed users in LAN. In a network, it provides asynchronous, multi-rate, multi-user communication with network scalability, re-configurability (bandwidth on demand), and network security (provided by inherent CDMA coding). However, optical CDMA technology is less mature in comparison to WDMA. The components requirements are also different from WDMA. We have demonstrated a video transport/switching system over a distance of 40 Km using discrete optical components in our laboratory. We are currently pursuing PIC implementation. In this paper, we will describe the optical CDMA concept/features, the demonstration system, and the requirements of some critical optical components such as broadband optical source, broadband optical amplifier, spectral spreading/de- spreading, and fixed/programmable mask.

  15. Method and apparatus for bistable optical information storage for erasable optical disks

    Science.gov (United States)

    Land, Cecil E.; McKinney, Ira D.

    1990-01-01

    A method and an optical device for bistable storage of optical information, together with reading and erasure of the optical information, using a photoactivated shift in a field dependent phase transition between a metastable or a bias-stabilized ferroelectric (FE) phase and a stable antiferroelectric (AFE) phase in an lead lanthanum zirconate titanate (PLZT). An optical disk contains the PLZT. Writing and erasing of optical information can be accomplished by a light beam normal to the disk. Reading of optical information can be accomplished by a light beam at an incidence angle of 15 to 60 degrees to the normal of the disk.

  16. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    .... Focusing on applications of quantum optics, the textbook covers recent developments such as engineering of quantum states, quantum optics on a chip, nano-mechanical mirrors, quantum entanglement...

  17. Precision Cleaning and Protection of Coated Optical Components for NIF Small Optics

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, Jim [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-19

    The purpose of this procedure shall be to define the precision cleaning of finished, coated, small optical components for NIF at Lawrence Livermore National Laboratories. The term “small optical components” includes coated optics that are set into simple mounts, as well as coated, un-mounted optics.

  18. Characterization of transimpedance amplifier as optical to electrical converter on designing optical instrumentation

    International Nuclear Information System (INIS)

    Hanto, D; Ula, R K

    2017-01-01

    Optical to electrical converter is the main components for designing of the optical instrumentations. In addition, this component is also used as signal conditioning. This component usually consists of a photo detector and amplifier. In this paper, characteristics of commercial amplifiers from Thorlabs PDA50B-EC has been observed. The experiment was conducted by diode laser with power of -5 dBm and wavelength 1310 nm; the optical attenuator to vary optical power from 0 to 60 dB, optical to electrical converter from Thorlabs Amplifier PDA50B-EC; multimode optical fiber to guide the laser; and digital voltmeter to measure the output of converter. The results of the characterization indicate that each channel amplification has a non-linear correlation between optical and electrical parameter; optical conversion measurement range of 20-23 dB to full scale; and different measurement coverage area. If this converter will be used as a part component of optical instrumentation so it should be adjusted suitably with the optical power source. Then, because of the correlation equation is not linear so calculation to determine the interpretation also should be considered in addition to the transfer function of the optical sensor. (paper)

  19. Characterization of transimpedance amplifier as optical to electrical converter on designing optical instrumentation

    Science.gov (United States)

    Hanto, D.; Ula, R. K.

    2017-05-01

    Optical to electrical converter is the main components for designing of the optical instrumentations. In addition, this component is also used as signal conditioning. This component usually consists of a photo detector and amplifier. In this paper, characteristics of commercial amplifiers from Thorlabs PDA50B-EC has been observed. The experiment was conducted by diode laser with power of -5 dBm and wavelength 1310 nm; the optical attenuator to vary optical power from 0 to 60 dB, optical to electrical converter from Thorlabs Amplifier PDA50B-EC; multimode optical fiber to guide the laser; and digital voltmeter to measure the output of converter. The results of the characterization indicate that each channel amplification has a non-linear correlation between optical and electrical parameter; optical conversion measurement range of 20-23 dB to full scale; and different measurement coverage area. If this converter will be used as a part component of optical instrumentation so it should be adjusted suitably with the optical power source. Then, because of the correlation equation is not linear so calculation to determine the interpretation also should be considered in addition to the transfer function of the optical sensor.

  20. Advances in nonlinear optics

    CERN Document Server

    Chen, Xianfeng; Zeng, Heping; Guo, Qi; She, Weilong

    2015-01-01

    This book presents an overview of the state of the art of nonlinear optics from weak light nonlinear optics, ultrafast nonlinear optics to electro-optical theory and applications. Topics range from the fundamental studies of the interaction between matter and radiation to the development of devices, components, and systems of tremendous commercial interest for widespread applications in optical telecommunications, medicine, and biotechnology.

  1. Digital diffractive optics: Have diffractive optics entered mainstream industry yet?

    Science.gov (United States)

    Kress, Bernard; Hejmadi, Vic

    2010-05-01

    When a new technology is integrated into industry commodity products and consumer electronic devices, and sold worldwide in retail stores, it is usually understood that this technology has then entered the realm of mainstream technology and therefore mainstream industry. Such a leap however does not come cheap, as it has a double edge sword effect: first it becomes democratized and thus massively developed by numerous companies for various applications, but also it becomes a commodity, and thus gets under tremendous pressure to cut down its production and integration costs while not sacrificing to performance. We will show, based on numerous examples extracted from recent industry history, that the field of Diffractive Optics is about to undergo such a major transformation. Such a move has many impacts on all facets of digital diffractive optics technology, from the optical design houses to the micro-optics foundries (for both mastering and volume replication), to the final product integrators or contract manufacturers. The main causes of such a transformation are, as they have been for many other technologies in industry, successive technological bubbles which have carried and lifted up diffractive optics technology within the last decades. These various technological bubbles have been triggered either by real industry needs or by virtual investment hype. Both of these causes will be discussed in the paper. The adjective ""digital"" in "digital diffractive optics" does not refer only, as it is done in digital electronics, to the digital functionality of the element (digital signal processing), but rather to the digital way they are designed (by a digital computer) and fabricated (as wafer level optics using digital masking techniques). However, we can still trace a very strong similarity between the emergence of micro-electronics from analog electronics half a century ago, and the emergence of digital optics from conventional optics today.

  2. Optical electronics

    CERN Document Server

    Yariv, Amnon

    1991-01-01

    This classic text introduces engineering students to the first principles of major phenomena and devices of optoelectronics and optical communication technology. Yariv's "first principles" approach employs real-life examples and extensive problems. The text includes separate chapters on quantum well and semiconductor lasers, as well as phase conjugation and its applications. Optical fiber amplification, signal and noise considerations in optical fiber systems, laser arrays and distributed feedback lasers all are covered extensively in major sections within chapters.

  3. Random photonic crystal optical memory

    International Nuclear Information System (INIS)

    Wirth Lima Jr, A; Sombra, A S B

    2012-01-01

    Currently, optical cross-connects working on wavelength division multiplexing systems are based on optical fiber delay lines buffering. We designed and analyzed a novel photonic crystal optical memory, which replaces the fiber delay lines of the current optical cross-connect buffer. Optical buffering systems based on random photonic crystal optical memory have similar behavior to the electronic buffering systems based on electronic RAM memory. In this paper, we show that OXCs working with optical buffering based on random photonic crystal optical memories provides better performance than the current optical cross-connects. (paper)

  4. Tunable micro-optics

    CERN Document Server

    Duppé, Claudia

    2015-01-01

    Presenting state-of-the-art research into the dynamic field of tunable micro-optics, this is the first book to provide a comprehensive survey covering a varied range of topics including novel materials, actuation concepts and new imaging systems in optics. Internationally renowned researchers present a diverse range of chapters on cutting-edge materials, devices and subsystems, including soft matter, artificial muscles, tunable lenses and apertures, photonic crystals, and complete tunable imagers. Special contributions also provide in-depth treatment of micro-optical characterisation, scanners, and the use of natural eye models as inspiration for new concepts in advanced optics. With applications extending from medical diagnosis to fibre telecommunications, Tunable Micro-optics equips readers with a solid understanding of the broader technical context through its interdisciplinary approach to the realisation of new types of optical systems. This is an essential resource for engineers in industry and academia,...

  5. Anterior ischemic optic neuropathy in association with optic nervehead drusen

    Directory of Open Access Journals (Sweden)

    Bharathi Megur

    2014-01-01

    Full Text Available Optic nerve head drusen (ONHD are incidental ophthalmologic finding in the optic nerve. Patients with ONHD are often asymptomatic, but sometimes present with transient visual obscuration′s (TVO, the reported incidence of which is 8.6%. Optic nerve head drusen are of two types: Superficial; visible and deep. The deep-buried drusen mimic papilledema. Because of the varied presentation deep-buried drusen pose a diagnostic challenge to the ophthalmologists. In young patients, they are mistaken for papilledema as it is clinically difficult to detect a buried drusen in the optic nerve head, but are seen on the surface with aging as the retinal nerve fiber layer thins out. They are observed as pale yellow lesions more often located towards the poles. Clinical examination aided with diagnostic tests like computed tomography (CT orbits and ultrasound B scan can help establish the diagnosis. Herein, we report a rare case of optic nerve head drusen in a young lady, who presented with loss of vision and clinical evaluation and investigations suggested ONHD with anterior ischemic optic neuropathy.

  6. Introduction to nonimaging optics

    CERN Document Server

    Chaves, Julio

    2015-01-01

    Introduction to Nonimaging Optics covers the theoretical foundations and design methods of nonimaging optics, as well as key concepts from related fields. This fully updated, revised, and expanded Second Edition: Features a new and intuitive introduction with a basic description of the advantages of nonimaging opticsAdds new chapters on wavefronts for a prescribed output (irradiance or intensity), infinitesimal étendue optics (generalization of the aplanatic optics), and Köhler optics and color mixingIncorporates new material on the simultaneous multiple surface (SMS) design method in 3-D, int

  7. Optical Coherence and Quantum Optics

    CERN Document Server

    Mandel, Leonard

    1995-01-01

    This book presents a systematic account of optical coherence theory within the framework of classical optics, as applied to such topics as radiation from sources of different states of coherence, foundations of radiometry, effects of source coherence on the spectra of radiated fields, coherence theory of laser modes, and scattering of partially coherent light by random media. The book starts with a full mathematical introduction to the subject area and each chapter concludes with a set of exercises. The authors are renowned scientists and have made substantial contributions to many of the topi

  8. Optical Filter Assembly for Interplanetary Optical Communications

    Science.gov (United States)

    Chen, Yijiang; Hemmati, Hamid

    2013-01-01

    Ground-based, narrow-band, high throughput optical filters are required for optical links from deep space. We report on the development of a tunable filter assembly that operates at telecommunication window of 1550 nanometers. Low insertion loss of 0.5 decibels and bandwidth of 90 picometers over a 2000 nanometers operational range of detectors has been achieved.

  9. Progress in optics

    CERN Document Server

    Wolf, Emil

    2009-01-01

    In the fourty-seven years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. The volumes in this series which have appeared up to now contain more than 300 review articles by distinguished research workers, which have become permanent records for many important developments.- Backscattering and Anderson localization of light- Advances in oliton manipulation in optical lattices- Fundamental quantum noise in optical amplification- Invisibility cloaks

  10. Elementary wave optics

    CERN Document Server

    Webb, Robert H

    2005-01-01

    This undergraduate textbook presents thorough coverage of the standard topics of classical optics and optical instrument design; it also offers significant details regarding the concepts of modern optics. Its survey of the mathematical tools of optics grants students insights into the physical principles of quantum mechanics.Two principal concepts occur throughout: a treatment of scattering from real scatterers (leading to Huygens' principles, diffraction theory, the index of refraction, and related topics); and the difference between coherent and noncoherent wave phenomena. Examinations of su

  11. Optically resilient 3D micro-optics on the tips of optical fibers

    Science.gov (United States)

    Jonušauskas, Linas

    2017-05-01

    In this paper we present a study aimed at investigating an optical resiliency of polymers that could be applied in 3D femtosecond laser lithography. These include popular in lithography SU8 and OrmoClear as well as hybrid organic-inorganic zirconium containing SZ2080. We show that latter material in its pure (non-photosensitized) form has the best optical resiliency out of all tested materials. Furthermore, its 3D structurability is investigated. Despite threshold-like quality degradation outside fabrication window, we show that this material is suitable for creating complex 3D structures on the tips of optical fibers. Overall it is demonstrated, that unique capability of 3DLL to structure pure materials can lead to very compact functional fiber-based devices that could withstand high (GW/cm2) light intensities.

  12. High-speed optical feeder-link system using adaptive optics

    Science.gov (United States)

    Arimoto, Yoshinori; Hayano, Yutaka; Klaus, Werner

    1997-05-01

    We propose a satellite laser communication system between a ground station and a geostationary satellite, named high- speed optical feeder link system. It is based on the application of (a) high-speed optical devices, which have been developed for ground-based high-speed fiber-optic communications, and (b) the adaptive optics which compensates wavefront distortions due to atmospheric turbulences using a real time feedback control. A link budget study shows that a system with 10-Gbps bit-rate are available assuming the state-of-the-art device performance of the Er-doped fiber amplifier. We further discuss preliminary measurement results of the atmospheric turbulence at the telescope site in Tokyo, and present current study on the design of the key components for the feeder-link laser transceiver.

  13. Progress in optics

    CERN Document Server

    Wolf, Emil

    2015-01-01

    The Progress in Optics series contains more than 300 review articles by distinguished research workers, which have become permanent records for many important developments, helping optical scientists and optical engineers stay abreast of their fields. Comprehensive, in-depth reviewsEdited by the leading authority in the field

  14. Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hoang Duc, Albert K., E-mail: albert.hoangduc.ucl@gmail.com; McClelland, Jamie; Modat, Marc; Cardoso, M. Jorge; Mendelson, Alex F. [Center for Medical Image Computing, University College London, London WC1E 6BT (United Kingdom); Eminowicz, Gemma; Mendes, Ruheena; Wong, Swee-Ling; D’Souza, Derek [Radiotherapy Department, University College London Hospitals, 235 Euston Road, London NW1 2BU (United Kingdom); Veiga, Catarina [Department of Medical Physics and Bioengineering, University College London, London WC1E 6BT (United Kingdom); Kadir, Timor [Mirada Medical UK, Oxford Center for Innovation, New Road, Oxford OX1 1BY (United Kingdom); Ourselin, Sebastien [Centre for Medical Image Computing, University College London, London WC1E 6BT (United Kingdom)

    2015-09-15

    Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic

  15. The use of hypofractionated intensity-modulated irradiation in the treatment of glioblastoma multiforme: preliminary results of a prospective trial.

    Science.gov (United States)

    Sultanem, Khalil; Patrocinio, Horacio; Lambert, Christine; Corns, Robert; Leblanc, Richard; Parker, William; Shenouda, George; Souhami, Luis

    2004-01-01

    Despite major advances in treatment modalities, the prognosis of patients with glioblastoma multiforme (GBM) remains poor. Exploring hypofractionated regimens to replace the standard 6-week radiotherapy schedule is an attractive strategy as an attempt to prevent accelerated tumor cell repopulation. There is equally interest in dose escalation to the gross tumor volume where the majority of failures occur. We report our preliminary results using hypofractionated intensity-modulated accelerated radiotherapy regimen in the treatment of patients with GBM. Between July 1998 and December 2001, 25 patients with histologically proven diagnosis of GBM, Karnofsky performance status > or =60, and a postoperative tumor volume step-and-shoot technique), 60 Gy in 20 daily fractions of 3 Gy each were given to the GTV, whereas the planning target volume received a minimum of 40 Gy in 20 fractions of 2 Gy each at its periphery. Treatments were delivered over a 4-week period using 5 daily fractions per week. Dose was prescribed at the isocenter (ICRU point). Three beam angles were used in all of the cases. Treatments were well tolerated. Acute toxicity was limited to increased brain edema during radiotherapy in 2 patients who were on tapering doses of corticosteroids. This was corrected by increasing the steroid dose. At a median follow-up of 8.8 months, no late toxicity was observed. One patient experienced visual loss at 9 months after completion of treatment. MRI suggested nonspecific changes to the optic chiasm. On review of the treatment plan, the total dose to the optic chiasm was confirmed to be equal to or less than 40 Gy in 20 fractions. When Radiation Therapy Oncology Group recursive partitioning analysis was used, 10 patients were class III-IV, and 15 patients were class V-VI. To date, 21 patients have had clinical and/or radiologic evidence of disease progression, and 16 patients have died. The median survival was 9.5 months (range: 2.8-22.9 months), the 1-year survival

  16. Electro-optics laboratory evaluation: Deutsch optical waveguide connectors

    Science.gov (United States)

    1980-01-01

    A description of a test program evaluating the performance of an optical waveguide connector system is presented. Both quality and effectiveness of connections made in an optical fiber, performance of the equipment used and applicability of equipment and components to field conditions are reviewed.

  17. Dynamically tunable optical bottles from an optical fiber

    DEFF Research Database (Denmark)

    Chen, Yuhao; Yan, Lu; Rishøj, Lars Søgaard

    2012-01-01

    Optical fibers have long been used to impose spatial coherence to shape free-space optical beams. Recent work has shown that one can use higher order fiber modes to create more exotic beam profiles. We experimentally generate optical bottles from Talbot imaging in the coherent superposition of two...... fiber modes excited with long period gratings, and obtain a 28 μm × 6 μm bottle with controlled contrast up to 10.13 dB. Our geometry allows for phase tuning of one mode with respect to the other, which enables us to dynamically move the bottle in free space....

  18. Optical microparticle manipulation advances and new capabilities offered by diffractive optics

    International Nuclear Information System (INIS)

    Sojfer, V.A.; Kotlyar, V.V.; Khonina, S.N.

    2004-01-01

    The review deals with a promising area in laser optics - optical manipulation. The object under manipulation can be of various nature: from a colloid particle to a molecule, from cell, virus, to a micromechanism part, etc. In the first part of this work a concise review of the articles on optical manipulation of microparticles and atoms published in the last two decades is presented. The second part is devoted t the production of laser beams with self-reproduction properties. Such beams can be most effectively produced using diffractive optical elements (DOEs). The DOE-generated self-reproducing laser beams (stable, axially periodic, rotating, and multiorder) offer new opportunities in optical manipulation of micro- and nano-objects [ru

  19. Optical annealing of CaF2:Mn for cooled optically stimulated luminescence

    International Nuclear Information System (INIS)

    Miller, S.D.; Stahl, K.A.; Endres, G.W.R.; McDonald, J.C.

    1989-01-01

    Optical annealing of the cooled optically stimulated luminescence in CaF 2 :Mn at room temperature has been demonstrated. The laser of choice for optical annealing of CaF 2 : Mn is a 326 nm helium-cadmium ultraviolet laser. A complete cycle of readout and annealing of the CaF 2 :Mn cooled optically stimulated dosemeters can now be accomplished without heating the dosemeters above room temperature. This annealing work represents the next step toward creating a proton-recoil-based fast neutron dosimetry system based on the cooled optically stimulated luminescence technique. (author)

  20. Phase-preserved optical elevator

    OpenAIRE

    Luo, Yuan; Zhang, Baile; Han, Tiancheng; Chen, Zhi; Duan, Yubo; Chu, Chia-Wei; Barbastathis, George; Qiu, Cheng Wei

    2013-01-01

    The unique superiority of transformation optics devices designed from coordinate transformation is their capability of recovering both ray trajectory and optical path length in light manipulation. However, very few experiments have been done so far to verify this dual-recovery property from viewpoints of both ray trajectory and optical path length simultaneously. The experimental difficulties arise from the fact that most previous optical transformation optics devices only work at the nano-sc...

  1. Integrated Optical Circuit Engineering

    Science.gov (United States)

    Sriram, S.

    1985-04-01

    Implementation of single-mode optical fiber systems depends largely on the availability of integrated optical components for such functions as switching, multiplexing, and modulation. The technology of integrated optics is maturing very rapidly, and its growth justifies the optimism that now exists in the optical community.

  2. Proton radiation therapy (prt) for pediatric optic pathway gliomas: comparison with 3d planned conventional photons and a standard photon technique

    International Nuclear Information System (INIS)

    Fuss, Martin; Hug, Eugen B.; Schaefer, Rosemary A.; Nevinny-Stickel, Meinhard; Miller, Daniel W.; Slater, James M.; Slater, Jerry D.

    1999-01-01

    advantage was equalized for larger tumors. At the lowest isodose level, 3D photons encompassed the highest amount of NT. Analysis of organs at risk showed that PRT reduced doses to the contralateral optic nerve by 47% and 77% compared to 3D photons and lateral photons, respectively. Reductions were also seen for the chiasm (11% and 16%) and pituitary gland (13% and 16%), with differences at clinically relevant tolerance levels. Furthermore, reduced dose exposure of both temporal lobes (sparing 39% and 54%) and frontal lobes was achieved with PRT. Conclusion: PRT offered a high degree of conformity to target volumes and steep dose gradients, thus leading to substantial normal tissue sparing in high- and low-dose areas. It is expected that this will result in decreased long-term toxicity in the maturing child. Advantages of proton versus 3D photon plans became increasingly apparent with increasing target size and tumor complexity. Even in small tumors, conformity of 3D photon irradiation came at the expense of a larger amount of NT receiving moderate to low radiation doses. Lateral photons resulted in inferior dose distribution with high radiation exposure of clinically relevant normal tissues

  3. Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

    Science.gov (United States)

    Downie, John D.

    1990-01-01

    A ground-based adaptive optics imaging telescope system attempts to improve image quality by detecting and correcting for atmospherically induced wavefront aberrations. The required control computations during each cycle will take a finite amount of time. Longer time delays result in larger values of residual wavefront error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper presents a study of the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for the adaptive optics application. An optimization of the adaptive optics correction algorithm with respect to an optical processor's degree of accuracy is also briefly discussed.

  4. Optical holography

    CERN Document Server

    Collier, Robert J; Lin, Lawrence H

    1971-01-01

    Optical Holography deals with the use of optical holography to solve technical problems, with emphasis on the properties of holograms formed with visible light. Topics covered include the Fourier transform, propagation and diffraction, pulsed-laser holography, and optical systems with spherical lenses. A geometric analysis of point-source holograms is also presented, and holograms and hologram spatial filters formed with spatially modulated reference waves are described. This book is comprised of 20 chapters and begins with an introduction to concepts that are basic to understanding hologr

  5. [Clinical feature of chronic compressive optic neuropathy without optic atrophy].

    Science.gov (United States)

    Jiang, Libin; Shi, Jitong; Liu, Wendong; Kang, Jun; Wang, Ningli

    2014-12-01

    To investigate the clinical feature of the chronic compressive optic neuropathy without optic atrophy. Retrospective cases series study. The clinical data of 25 patients (37 eyes) with chronic compressive optic neuropathy without optic atrophy, treated in Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, from October, 2005 to March, 2014, were collected. Those patients had been showing visual symptoms for 6 months or longer, but missed diagnosed or misdiagnosed as other eye diseases due to their normal or slightly changed fundi. The collected data including visual acuities, visual fields, neuroimaging and/or pathologic diagnosis were analyzed. Among the 25 patients, there were 5 males and 20 females, and their ages range from 9 to 74 years [average (47.5 ± 13.4) years]. All patients suffered progressive impaired vision in single eye or both eyes, without exophthalmos or abnormal eye movements. Except one patient had a headache, other patients did not show systemic symptoms. The corrected visual acuities were between HM to 1.0, and their appearances of optic discs and colors of fundi were normal. After neuroimaging and/or pathological examination, it was proven that 14 patients suffered tuberculum sellae meningiomas, 5 patients with hypophysoma, 3 patient with optic nerve sheath meningioma in orbital apex, 1 patient with cavernous hemangioma, 1 patient with vascular malformation in orbital apex and 1 patient with optic nerve glioma. Among the 19 patients whose suffered occupied lesions of saddle area, 14 patients underwent visual field examinations, and only 4 patients showed classic visual field defects caused by optic chiasmal lesions. Occult progressive visual loss was the most important clinical feature of the disease.

  6. Design and experimental verification for optical module of optical vector-matrix multiplier.

    Science.gov (United States)

    Zhu, Weiwei; Zhang, Lei; Lu, Yangyang; Zhou, Ping; Yang, Lin

    2013-06-20

    Optical computing is a new method to implement signal processing functions. The multiplication between a vector and a matrix is an important arithmetic algorithm in the signal processing domain. The optical vector-matrix multiplier (OVMM) is an optoelectronic system to carry out this operation, which consists of an electronic module and an optical module. In this paper, we propose an optical module for OVMM. To eliminate the cross talk and make full use of the optical elements, an elaborately designed structure that involves spherical lenses and cylindrical lenses is utilized in this optical system. The optical design software package ZEMAX is used to optimize the parameters and simulate the whole system. Finally, experimental data is obtained through experiments to evaluate the overall performance of the system. The results of both simulation and experiment indicate that the system constructed can implement the multiplication between a matrix with dimensions of 16 by 16 and a vector with a dimension of 16 successfully.

  7. Design of an optical spatial interferometer with transformation optics

    International Nuclear Information System (INIS)

    Naghibi, Atefeh; Shokooh-Saremi, Mehrdad

    2015-01-01

    In this paper, we apply transformation optics to design an optical spatial interferometer. The transformation equations are described and two-dimensional finite element simulations are presented to numerically confirm the functionality of the device. It is shown that a small change in the refractive index can alter the interference pattern and hence can be detected. The design of the interferometer could expand transformation optics’ applications and make way for introduction of new structures with unique electromagnetic or optical functionalities. (paper)

  8. Performance of magneto-optical glass in optical current transducer application

    International Nuclear Information System (INIS)

    Shen, Yan; Lu, Yunhe; Liu, Zhao; Yu, Xueliang; Zhang, Guoqing; Yu, Wenbin

    2015-01-01

    First, a theoretical analysis was performed on the effect of temperature on the performance of the sensing element of paramagnetic rare earth-doped magneto-optical glass material that can be used in an optical current transducer application. The effect comprises two aspects: the linear birefringence and the Verdet constant. On this basis, rare earth-doped glass temperature characteristics were studied, and the experimental results indicated that the linear birefringence of rare earth-doped glass increased with increasing temperature, while its magneto-optical sensitivity decreased. Comparative experiments performed for various concentrations of rare earth dopant in the glass revealed that changes in the dopant concentration had no significant effect on the performance of magneto-optical glass. At last, a comparison between rare earth-doped magneto-optical and diamagnetic dense flint glass showed that the sensitivity of the former was six times that of the latter, although the temperature stability of the former was poorer. - Highlights: • Theoretical analysis on the effects of temperature on RE glass. • Rare earth doping leads to higher magneto-optical sensitivity. • The sensitivity of the RE glass is six times that of the dense flint glass

  9. Optical aurora detectors: using natural optics to motivate education and outreach

    Science.gov (United States)

    Shaw, Joseph A.; Way, Jesse M.; Pust, Nathan J.; Nugent, Paul W.; Coate, Hans; Balster, Daniel

    2009-06-01

    Natural optical phenomena enjoy a level of interest sufficiently high among a wide array of people to provide ideal education and outreach opportunities. The aurora promotes particularly high interest, perhaps because of its relative rarity in the areas of the world where most people live. A project is being conducted at Montana State University to use common interest and curiosity about auroras to motivate learning and outreach through the design and deployment of optical sensor systems that detect the presence of an auroral display and send cell phone messages to alert interested people. Project participants learn about the physics and optics of the aurora, basic principles of optical system design, radiometric calculations and calibrations, electro-optical detectors, electronics, embedded computer systems, and computer software. The project is moving into a stage where it will provide greatly expanded outreach and education opportunities as optical aurora detector kits are created and disbursed to colleges around our region.

  10. Geometric optics theory and design of astronomical optical systems using Mathematica

    CERN Document Server

    Romano, Antonio

    2016-01-01

    This text, now in its second edition, presents the mathematical background needed to design many optical combinations that are used in astronomical telescopes and cameras. It uses a novel approach to third-order aberration theory based on Fermat’s principle and the use of particular optical paths (called stigmatic paths) instead of rays, allowing for easier derivation of third-order formulae. Each optical combination analyzed is accompanied by a downloadable Mathematica® notebook that automates its third-order design, eliminating the need for lengthy calculations. The essential aspects of an optical system with an axis of rotational symmetry are introduced first, along with a development of Gaussian optics from Fermat’s principal. A simpler approach to third-order monochromatic aberrations based on both Fermat’s principle and stigmatic paths is then described, followed by a new chapter on fifth-order aberrations and their classification. Several specific optical devices are discussed and analyzed, incl...

  11. XIX International Youth School on Coherent Optics and Optical Spectroscopy

    International Nuclear Information System (INIS)

    2016-01-01

    The XIX International Youth School on Coherent Optics and Optical Spectroscopy (COOS2015) was held in Kazan, Russia, from October 5 to October 7 at the Nikolai Lobachevsky Scientific Library of Kazan Federal University. The School follows the global tendency toward comprehensive studies of matter properties and its interaction with electromagnetic fields. Since 1997 more than 100 famous scientists from USA, Germany, Ukraine, Belarussia and Russia had plenary lecture presentations. This is the right place, where over 1000 young scientists had an opportunity to participate in hot discussions regarding the latest scientific news. Many young people have submitted interesting reports on photonics, quantum electronics, laser physics, quantum optics, traditional optical and laser spectroscopy, non-linear optics, material science and nanotechnology. Here we are publishing the full-size papers prepared from the most interesting lectures and reports selected by the Program Committee of the School. (paper)

  12. Design of a multimodal fibers optic system for small animal optical imaging.

    Science.gov (United States)

    Spinelli, Antonello E; Pagliazzi, Marco; Boschi, Federico

    2015-02-01

    Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Measurement of optical glasses

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1978-11-01

    The possibilities of measurement of the optical glasses parameters needed in building optical devices especially in lasers devices are presented. In the first chapter the general features of the main optical glasses as well as the modalities of obtaining them are given. Chapter two defines the optical glass parameters, and the third chapter describes the measuring methods of the optical glass parameters. Finally, the conclusions which point out the utilization of this paper are presented. (author)

  14. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  15. Optical imaging and spectroscopy

    CERN Document Server

    Brady, David J

    2009-01-01

    An essential reference for optical sensor system design This is the first text to present an integrated view of the optical and mathematical analysis tools necessary to understand computational optical system design. It presents the foundations of computational optical sensor design with a focus entirely on digital imaging and spectroscopy. It systematically covers: Coded aperture and tomographic imaging Sampling and transformations in optical systems, including wavelets and generalized sampling techniques essential to digital system analysis Geometric, wave, and statis

  16. Optical and electro-optic anisotropy of epitaxial PZT thin films

    Science.gov (United States)

    Zhu, Minmin; Du, Zehui; Jing, Lin; Yoong Tok, Alfred Iing; Tong Teo, Edwin Hang

    2015-07-01

    Strong optical and electro-optic (EO) anisotropy has been investigated in ferroelectric Pb(Zr0.48Ti0.52)O3 thin films epitaxially grown on Nb-SrTiO3 (001), (011), and (111) substrates using magnetron sputtering. The refractive index, electro-optic, and ferroelectric properties of the samples demonstrate the significant dependence on the growth orientation. The linear electro-optic coefficients of the (001), (011), and (111)-oriented PZT thin films were 270.8, 198.8, and 125.7 pm/V, respectively. Such remarkable anisotropic EO behaviors have been explained according to the structure correlation between the orientation dependent distribution, spontaneous polarization, epitaxial strain, and domain pattern.

  17. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  18. Serial Diffusion Tensor Imaging of the Optic Radiations after Acute Optic Neuritis

    Directory of Open Access Journals (Sweden)

    Scott C. Kolbe

    2016-01-01

    Full Text Available Previous studies have reported diffusion tensor imaging (DTI changes within the optic radiations of patients after optic neuritis (ON. We aimed to study optic radiation DTI changes over 12 months following acute ON and to study correlations between DTI parameters and damage to the optic nerve and primary visual cortex (V1. We measured DTI parameters [fractional anisotropy (FA, axial diffusivity (AD, radial diffusivity (RD, and mean diffusivity (MD] from the optic radiations of 38 acute ON patients at presentation and 6 and 12 months after acute ON. In addition, we measured retinal nerve fibre layer thickness, visual evoked potential amplitude, optic radiation lesion load, and V1 thickness. At baseline, FA was reduced and RD and MD were increased compared to control. Over 12 months, FA reduced in patients at an average rate of −2.6% per annum (control = −0.51%; p=0.006. Change in FA, RD, and MD correlated with V1 thinning over 12 months (FA: R=0.450, p=0.006; RD: R=-0.428, p=0.009; MD: R=-0.365, p=0.029. In patients with no optic radiation lesions, AD significantly correlated with RNFL thinning at 12 months (R=0.489, p=0.039. In conclusion, DTI can detect optic radiation changes over 12 months following acute ON that correlate with optic nerve and V1 damage.

  19. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors

    Science.gov (United States)

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-01-01

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 µm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors. PMID:26437407

  20. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.

    Science.gov (United States)

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-09-30

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

  1. Latching micro optical switch

    Science.gov (United States)

    Garcia, Ernest J; Polosky, Marc A

    2013-05-21

    An optical switch reliably maintains its on or off state even when subjected to environments where the switch is bumped or otherwise moved. In addition, the optical switch maintains its on or off state indefinitely without requiring external power. External power is used only to transition the switch from one state to the other. The optical switch is configured with a fixed optical fiber and a movable optical fiber. The movable optical fiber is guided by various actuators in conjunction with a latching mechanism that configure the switch in one position that corresponds to the on state and in another position that corresponds to the off state.

  2. Compound semiconductor optical waveguide switch

    Science.gov (United States)

    Spahn, Olga B.; Sullivan, Charles T.; Garcia, Ernest J.

    2003-06-10

    An optical waveguide switch is disclosed which is formed from III-V compound semiconductors and which has a moveable optical waveguide with a cantilevered portion that can be bent laterally by an integral electrostatic actuator to route an optical signal (i.e. light) between the moveable optical waveguide and one of a plurality of fixed optical waveguides. A plurality of optical waveguide switches can be formed on a common substrate and interconnected to form an optical switching network.

  3. Circuit switched optical networks

    DEFF Research Database (Denmark)

    Kloch, Allan

    2003-01-01

    Some of the most important components required for enabling optical networking are investigated through both experiments and modelling. These all-optical components are the wavelength converter, the regenerator and the space switch. When these devices become "off-the-shelf" products, optical cross......, it is expected that the optical solution will offer an economical benefit for hight bit rate networks. This thesis begins with a discussion of the expected impact on communications systems from the rapidly growing IP traffic, which is expected to become the dominant source for traffic. IP traffic has some...... characteristics, which are best supported by an optical network. The interest for such an optical network is exemplified by the formation of the ACTS OPEN project which aim was to investigate the feasibility of an optical network covering Europe. Part of the work presented in this thesis is carried out within...

  4. Microscale optical cryptography using a subdiffraction-limit optical key

    Science.gov (United States)

    Ogura, Yusuke; Aino, Masahiko; Tanida, Jun

    2018-04-01

    We present microscale optical cryptography using a subdiffraction-limit optical pattern, which is finer than the diffraction-limit size of the decrypting optical system, as a key and a substrate with a reflectance distribution as an encrypted image. Because of the subdiffraction-limit spatial coding, this method enables us to construct a secret image with the diffraction-limit resolution. Simulation and experimental results demonstrate, both qualitatively and quantitatively, that the secret image becomes recognizable when and only when the substrate is illuminated with the designed key pattern.

  5. Fiber Optic Microphone

    Science.gov (United States)

    Cho, Y. C.; George, Thomas; Norvig, Peter (Technical Monitor)

    1999-01-01

    Research into advanced pressure sensors using fiber-optic technology is aimed at developing compact size microphones. Fiber optic sensors are inherently immune to electromagnetic noise, and are very sensitive, light weight, and highly flexible. In FY 98, NASA researchers successfully designed and assembled a prototype fiber-optic microphone. The sensing technique employed was fiber optic Fabry-Perot interferometry. The sensing head is composed of an optical fiber terminated in a miniature ferrule with a thin, silicon-microfabricated diaphragm mounted on it. The optical fiber is a single mode fiber with a core diameter of 8 micron, with the cleaved end positioned 50 micron from the diaphragm surface. The diaphragm is made up of a 0.2 micron thick silicon nitride membrane whose inner surface is metallized with layers of 30 nm titanium, 30 nm platinum, and 0.2 micron gold for efficient reflection. The active sensing area is approximately 1.5 mm in diameter. The measured differential pressure tolerance of this diaphragm is more than 1 bar, yielding a dynamic range of more than 100 dB.

  6. Time domain optical spectrometry with fiber optic waveguides

    International Nuclear Information System (INIS)

    Whitten, W.B.

    1983-01-01

    Spectrometers which use optical fibers to obtain time domain spectral dispersion are reviewed. Pulse transmission through fiber optic waveguides is discussed and the basic requirements for sources and detectors are given. Multiplex spectrometry and time-of-flight spectrometry are then discussed. Resolution, fiber requirements, instrumentation and specific spectrometers are presented

  7. Genetic relationships among three species of the genus @iSardinella@@ (Clupeidae)

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    no alleles. Nei's genetic distance values ranged from 0.31 + or - 0.15 to 1.68 + or - 0.51. Four loci were polymorphic in @iS. albella@@, and three in @iS. fimbriata@@ at P=0.95 level. No locus was polymorphic by the 95% criterion in @iS. longiceps@@. Average...

  8. Optical Binding of Nanowires

    Czech Academy of Sciences Publication Activity Database

    Simpson, Stephen Hugh; Zemánek, Pavel; Marago, O.M.; Jones, P.H.; Hanna, S.

    2017-01-01

    Roč. 17, č. 6 (2017), s. 3485-3492 ISSN 1530-6984 R&D Projects: GA ČR GB14-36681G Grant - others:AV ČR(CZ) CNR-16-12 Program:Bilaterální spolupráce Institutional support: RVO:68081731 Keywords : optical binding nanowires * Brownian motion * self-organization * non-equilibrium thermodynamics * non-equilibrium steady state * spin-orbit coupling * emergent phenomena Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 12.712, year: 2016

  9. ''Atomic Optics'': Nonimaging Optics on the Nanoscale

    Energy Technology Data Exchange (ETDEWEB)

    Roland Winston Joseph O' Gallagher

    2005-01-15

    This is the final report for a one year close out extension of our basic research program that was established at the University of Chicago more than sixteen years ago to explore and develop the optical sub-discipline that has come to be known as ''nonimaging optics''. This program has been extremely fruitful, having both broadened the range of formalism available for workers in this field and led to the discovery of many new families of optical devices. These devices and techniques have applications wherever the efficient transport and transformation of light distributions are important, in particular in illumination, fiber optics, collection and concentration of sunlight, and the detection of faint light signals in physics and astrophysics. Over the past thirty years, Nonimaging Optics (Welford and Winston, 1989) has brought a fresh approach to the analysis of many problems in classical macro-scale optics. Through the application of phase-space concepts, statistical methods, thermodynamic arguments, etc., many previously established performance limits were able to be broken and many technical surprises with exciting practical applications were discovered. The most recent three-year phase of our long-term continuing program ended in late 2002 and emphasized extending our work in geometrical optics and expanding it to include some interesting questions in physical optics as well as in the new field of statistical optics. This report presents a survey of the basic history and concepts of nonimaging optics and reviews highlights and significant accomplishments over the past fifteen years. This is followed by a more detailed summary of recent research directions and accomplishments during the last three years. This most recent phase was marked by the broadening in scope to include a separate project involving a collaboration with an industrial partner, Science Applications International Corporation (SAIC). This effort was proposed and approved in

  10. Imaging of macrophage dynamics with optical coherence tomography in anterior ischemic optic neuropathy.

    Science.gov (United States)

    Kokona, Despina; Häner, Nathanael U; Ebneter, Andreas; Zinkernagel, Martin S

    2017-01-01

    Anterior ischemic optic neuropathy (AION) is a relatively common cause of visual loss and results from hypoperfusion of the small arteries of the anterior portion of the optic nerve. AION is the leading cause of sudden optic nerve related vision loss with approximately 10 cases per 100'000 in the population over 50 years. To date there is no established treatment for AION and therefore a better understanding of the events occurring at the level of the optic nerve head (ONH) would be important to design future therapeutic strategies. The optical properties of the eye allow imaging of the optic nerve in vivo, which is a part of the CNS, during ischemia. Experimentally laser induced optic neuropathy (eLiON) displays similar anatomical features as anterior ischemic optic neuropathy in humans. After laser induced optic neuropathy we show that hyperreflective dots in optical coherence tomography correspond to mononuclear cells in histology. Using fluorescence-activated flow cytometry (FACS) we found these cells to peak one week after eLiON. These observations were translated to OCT findings in patients with AION, where similar dynamics of hyperreflective dots at the ONH were identified. Our data suggests that activated macrophages can be identified as hyperreflective dots in OCT. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Optical analog transmission device

    International Nuclear Information System (INIS)

    Ikawa, Shinji.

    1994-01-01

    The present invention concerns a device such as electro-optical conversion elements, optoelectric-electric elements and optical transmission channel, not undergoing deleterious effects on the efficiency of conversion and transmission due to temperature, and aging change. That is, a sine wave superposing means superposes, on a detector signal to be transmitted, a sine-wave signal having a predetermined amplitude and at a frequency lower than that of the detector signal. An optoelectric conversion means converts the electric signal as the signal of the sine-wave signal superposing means into an optical signal and outputs the same to an optical transmitting channel. The optoelectric conversion means converts the transmitted signal to an electric signal. A discriminating means discriminates the electric signal into a detector signal and a sine-wave signal. A calculating means calculates an optical transmitting efficiency of the transmitting channel based on the amplitude of the discriminated sine-wave signal. A processing means compensates an amplitude value of the detector signals discriminated by the discriminating means based on the optical transmission efficiency. As a result, an optical analog transmission device can be attained, which conducts optical transmission at a high accuracy without undergoing the defective effects of the optical transmission efficiency. (I.S.)

  12. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors

    Directory of Open Access Journals (Sweden)

    Marie Pospíšilová

    2015-09-01

    Full Text Available This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS and biosensors (FOBS. Fiber optic sensor (FOS systems use the ability of optical fibers (OF to guide the light in the spectral range from ultraviolet (UV (180 nm up to middle infrared (IR (10 μm and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

  13. Optical measuring system with an interrogator and a polymer-based single-mode fibre optic sensor system

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to an optical measuring system comprising a polymer-based single-mode fibre-optic sensor system (102), an optical interrogator (101), and an optical arrangement (103) interconnecting the optical interrogator (101) and the polymer-based single-mode fibre-optic sensor...... system (102). The invention further relates to an optical interrogator adapted to be connected to a polymer-based single-mode fibre-optic sensor system via an optical arrangement. The interrogator comprises a broadband light source arrangement (104) and a spectrum analysing arrangement which receives...

  14. Spectral domain optical coherence tomography morphology in optic disc pit associated maculopathy

    Directory of Open Access Journals (Sweden)

    Janusz Michalewski

    2014-01-01

    Full Text Available Purpose: Our purpose was to study the clinical manifestation and course of optic pit maculopathy using Spectral Domain Optical Coherence Tomography (SD- OCT images. Materials and Methods: We used SD-OCT to examine 20 eyes of 19 patients with a macular detachment in combination with an optic. Results: We observed five different fovea appearances in regard to fluid localization. In five eyes, we recorded changes in the fluid distribution with SD-OCT. In 17/20 eyes, we noted a communication between the perineural and subretinal and/or intraretinal space at the margin of the optic disc. Conclusion: 3-dimensional SD-OCT (3D-SDOCT scans revealed a three-fold connection, between subretinal and intraretinal space, perineural space, and the vitreous cavity. Therefore, we suppose that intraretinal or subretinal fluid in optic pit maculopathy may have both a vitreous and cerebrospinal origin. A membrane, covering the optic nerve was noted in 14 cases. Even if it seems intact in some B-scans, it is not complete in others several micrometers apart. Additionally, we observed fluid accumulation below the margin of the optic disc and hyperreflective porous tissue in the optic disc excavation. Those findings do not influence the course of maculopathy.

  15. Optics for engineers

    CERN Document Server

    DiMarzio, Charles A

    2011-01-01

    This book is an excellent resource for teaching any student or scientist who needs to use optical systems. I particularly like the addition of MATLAB scripts and functions. Highly recommended.-Professor James C. Wyant, Dean of College of Optical Sciences, University of ArizonaHis book is clear, concise and highly readable. This is an excellent text.-Professor Changhuei Yang, California Institute of TechnologyAt last, a book on optics that is written with the practising engineer in mind. I have been teaching optics to engineers for many years and have often longed for a text aimed at my student

  16. Optical Access Networks

    Science.gov (United States)

    Zheng, Jun; Ansari, Nirwan

    2005-06-01

    Call for Papers: Optical Access Networks With the wide deployment of fiber-optic technology over the past two decades, we have witnessed a tremendous growth of bandwidth capacity in the backbone networks of today's telecommunications infrastructure. However, access networks, which cover the "last-mile" areas and serve numerous residential and small business users, have not been scaled up commensurately. The local subscriber lines for telephone and cable television are still using twisted pairs and coaxial cables. Most residential connections to the Internet are still through dial-up modems operating at a low speed on twisted pairs. As the demand for access bandwidth increases with emerging high-bandwidth applications, such as distance learning, high-definition television (HDTV), and video on demand (VoD), the last-mile access networks have become a bandwidth bottleneck in today's telecommunications infrastructure. To ease this bottleneck, it is imperative to provide sufficient bandwidth capacity in the access networks to open the bottleneck and thus present more opportunities for the provisioning of multiservices. Optical access solutions promise huge bandwidth to service providers and low-cost high-bandwidth services to end users and are therefore widely considered the technology of choice for next-generation access networks. To realize the vision of optical access networks, however, many key issues still need to be addressed, such as network architectures, signaling protocols, and implementation standards. The major challenges lie in the fact that an optical solution must be not only robust, scalable, and flexible, but also implemented at a low cost comparable to that of existing access solutions in order to increase the economic viability of many potential high-bandwidth applications. In recent years, optical access networks have been receiving tremendous attention from both academia and industry. A large number of research activities have been carried out or

  17. Optical pulse coupling in a photorefractive crystal, propagation of encoded pulses in an optical fiber, and phase conjugate optical interconnections

    Energy Technology Data Exchange (ETDEWEB)

    Yao, X.S.

    1992-01-01

    In Part I, the author presents a theory to describe the interaction between short optical pulses in a photorefractive crystal. This theory provides an analytical framework for pulse coherence length measurements using a photorefractive crystal. The theory also predicts how a pulse changes its temporal shape due to its coupling with another pulse in a photorefractive crystal. The author describes experiments to demonstrate how photorefractive coupling alters the temporal shape and the frequency spectrum of an optical pulse. The author describes a compact optical field correlator. Using this correlator, the author measured the field cross-correlation function of optical pulses using a photorefractive crystal. The author presents a more sophisticated theory to describe the photorefractive coupling of optical pulses that are too short for the previous theory to be valid. In Part II of this dissertation, the author analyzes how the group-velocity dispersion and the optical nonlinearity of an optical fiber ruin an fiberoptic code-division multiple-access (CDMA) communication system. The author treats the optical fiber's nonlinear response with a novel approach and derives the pulse propagation equation. Through analysis and numerically simulations, the author obtains the maximum and the maximum allowed peak pulse power, as well as the minimum and the maximum allowed pulse width for the communication system to function properly. The author simulates how the relative misalignment between the encoding and the decoding masks affects the system's performance. In Part III the author demonstrates a novel optical interconnection device based on a mutually pumped phase conjugator. This device automatically routes light from selected information-sending channels to selected information-receiving channels, and vice versa. The phase conjugator eliminates the need for critical alignment. It is shown that a large number of optical channels can be interconnected using this

  18. Optical design and testing: introduction.

    Science.gov (United States)

    Liang, Chao-Wen; Koshel, John; Sasian, Jose; Breault, Robert; Wang, Yongtian; Fang, Yi Chin

    2014-10-10

    Optical design and testing has numerous applications in industrial, military, consumer, and medical settings. Assembling a complete imaging or nonimage optical system may require the integration of optics, mechatronics, lighting technology, optimization, ray tracing, aberration analysis, image processing, tolerance compensation, and display rendering. This issue features original research ranging from the optical design of image and nonimage optical stimuli for human perception, optics applications, bio-optics applications, 3D display, solar energy system, opto-mechatronics to novel imaging or nonimage modalities in visible and infrared spectral imaging, modulation transfer function measurement, and innovative interferometry.

  19. [Adaptive optics for ophthalmology].

    Science.gov (United States)

    Saleh, M

    2016-04-01

    Adaptive optics is a technology enhancing the visual performance of an optical system by correcting its optical aberrations. Adaptive optics have already enabled several breakthroughs in the field of visual sciences, such as improvement of visual acuity in normal and diseased eyes beyond physiologic limits, and the correction of presbyopia. Adaptive optics technology also provides high-resolution, in vivo imaging of the retina that may eventually help to detect the onset of retinal conditions at an early stage and provide better assessment of treatment efficacy. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Photometric device using optical fibers

    International Nuclear Information System (INIS)

    Boisde, Gilbert; Perez, J.-J.

    1981-02-01

    Remote measurements in radioactive environment are now possible with optical fibers. Measurement instruments developed by CEA are constitued of: - an optical probe (5 mm to 1 meter optical path length), - a photometric measurement device, - optical fiber links. 'TELEPHOT' is a photometric device for industrial installations. It is uses interferentiel filters for 2 to 5 simultaneous wave lengths. 'CRUDMETER' measures the muddiness of water. It can be equipped with a high sensitivity cell of 50 cm optical path length tested up to 250 bars. Coupling a double beam spectrophotometer to a remote optical probe, up to 1 meter optical path length, is carried out by means of an optical device using optical fibers links, eventually several hundred meter long. For these equipments special step index large core fibers, 1 to 1.5 mm in diameter, have been developed as well connectors. For industrial control and research these instruments offer new prospect thanks to optical fibers use [fr

  1. Design of a Production Process to Enhance Optical Performance of 3(omega) Optics

    International Nuclear Information System (INIS)

    Prasad, R.R.; Bruere, J.R.; Halpin, J.; Lucero, P.; Mills, S.; Bernacil, M.; Hackel, R.P.

    2003-01-01

    Using the Phoenix pre-production conditioning facility we have shown that raster scanning of 3ω optics using a XeF excimer laser and mitigation of the resultant damage sites with a CO 2 laser can enhance their optical damage resistance. Several large-scale (43 cm x 43 cm) optics have been processed in this facility. A production facility capable of processing several large optics a week has been designed based on our experience in the pre-production facility. The facility will be equipped with UV conditioning lasers--351-nm XeF excimer lasers operating at 100 Hz and 23 ns. The facility will also include a CO 2 laser for damage mitigation, an optics stage for raster scanning large-scale optics, a damage mapping system (DMS) that images large-scale optics and can detect damage sites or precursors as small as ∼ 15 (micro)m, and two microscopes to image damage sites with ∼ 5 (micro)m resolution. The optics will be handled in a class 100 clean room, within the facility that will be maintained at class 1000

  2. Optical properties of marine waters and the development of bio-optical algorithms

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.

    This paper presents the primary optical variables used in the measurement of the optical properties of marine waters. How can in-situ measurements be used in the optical recognition of coastal and open ocean waters. We then look at bio...

  3. Correlator receiver architecture with PnpN optical thyristor operating as optical hard-limiter

    Science.gov (United States)

    Kang, Tae-Gu; Ho Lee, Su; Park, Soonchul

    2011-07-01

    We propose novel correlator receiver architecture with a PnpN optical thyristor operating as optical hard-limiter, and demonstrate a multiple-access interference rejection of the proposed correlator receiver. The proposed correlator receiver is composed of the 1×2 splitter, optical delay line, 2×1 combiner, and fabricated PnpN optical thyristor. The proposed correlator receiver enhances the system performance because it excludes some combinations of multiple-access interference patterns from causing errors as in optical code-division multiple access systems with conventional optical receiver shown in all previous works. It is found that the proposed correlator receiver can fully reject the interference signals generated by decoding processing and multiple access for two simultaneous users.

  4. Gradient-Index Optics

    Science.gov (United States)

    2010-03-31

    nonimaging design capabilities to incorporate 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 12-04-2011 13. SUPPLEMENTARY NOTES The views, opinions...Box 12211 Research Triangle Park, NC 27709-2211 15. SUBJECT TERMS Imaging Optics, Nonimaging Optics, Gradient Index Optics, Camera, Concentrator...imaging and nonimaging design capabilities to incorporate manufacturable GRIN lenses can provide imaging lens systems that are compact and

  5. Multiplane optical microscope

    Science.gov (United States)

    Li, Tongcang; Ota, Sadao; Kim, Jeongmin; Wang, Yuan; Zhang, Xiang

    2017-11-21

    This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.

  6. Computational adaptive optics for broadband optical interferometric tomography of biological tissue.

    Science.gov (United States)

    Adie, Steven G; Graf, Benedikt W; Ahmad, Adeel; Carney, P Scott; Boppart, Stephen A

    2012-05-08

    Aberrations in optical microscopy reduce image resolution and contrast, and can limit imaging depth when focusing into biological samples. Static correction of aberrations may be achieved through appropriate lens design, but this approach does not offer the flexibility of simultaneously correcting aberrations for all imaging depths, nor the adaptability to correct for sample-specific aberrations for high-quality tomographic optical imaging. Incorporation of adaptive optics (AO) methods have demonstrated considerable improvement in optical image contrast and resolution in noninterferometric microscopy techniques, as well as in optical coherence tomography. Here we present a method to correct aberrations in a tomogram rather than the beam of a broadband optical interferometry system. Based on Fourier optics principles, we correct aberrations of a virtual pupil using Zernike polynomials. When used in conjunction with the computed imaging method interferometric synthetic aperture microscopy, this computational AO enables object reconstruction (within the single scattering limit) with ideal focal-plane resolution at all depths. Tomographic reconstructions of tissue phantoms containing subresolution titanium-dioxide particles and of ex vivo rat lung tissue demonstrate aberration correction in datasets acquired with a highly astigmatic illumination beam. These results also demonstrate that imaging with an aberrated astigmatic beam provides the advantage of a more uniform depth-dependent signal compared to imaging with a standard gaussian beam. With further work, computational AO could enable the replacement of complicated and expensive optical hardware components with algorithms implemented on a standard desktop computer, making high-resolution 3D interferometric tomography accessible to a wider group of users and nonspecialists.

  7. Silicon Optical Modulator Simulation

    Directory of Open Access Journals (Sweden)

    Soon Thor LIM

    2015-04-01

    Full Text Available We developed a way of predicting and analyzing high speed optical modulator. Our research adopted a bottom-up approach to consider high-speed optical links using an eye diagram. Our method leverages on modular mapping of electrical characteristics to optical characteristics, while attaining the required accuracy necessary for device footprint approaching sub-micron scales where electrical data distribution varies drastically. We calculate for the bias dependent phase shift (2pi/mm and loss (dB/mm for the optical modulator based on the real and imaginary part of complex effective indices. Subsequently, combine effectively both the electrical and optical profiles to construct the optical eye diagram which is the essential gist of signal integrity of such devices.

  8. Nonlinear optics

    CERN Document Server

    Bloembergen, Nicolaas

    1996-01-01

    Nicolaas Bloembergen, recipient of the Nobel Prize for Physics (1981), wrote Nonlinear Optics in 1964, when the field of nonlinear optics was only three years old. The available literature has since grown by at least three orders of magnitude.The vitality of Nonlinear Optics is evident from the still-growing number of scientists and engineers engaged in the study of new nonlinear phenomena and in the development of new nonlinear devices in the field of opto-electronics. This monograph should be helpful in providing a historical introduction and a general background of basic ideas both for expe

  9. Fiber optics: A brief introduction

    International Nuclear Information System (INIS)

    Gruchalla, M.E.

    1989-01-01

    A basic introduction into the principles of fiber optics is presented. A review of both the underlying physical principles and the individual elements of typical fiber-optic systems are presented. The optical phenomenon of total internal reflection is reviewed. The basic construction of the optical fiber is presented. Both step-index and graded-index fiber designs are reviewed. Multimode and single-mode fiber constructions are considered and typical performance parameters given. Typical optical-fiber bandwidth and loss characteristics are compared to various common coaxial cables, waveguides, and air transmission. The constructions of optical-fiber cables are reviewed. Both loose-tube and tightly-buffered designs are considered. Several optical connection approaches are presented. Photographs of several representative optical connectors are included. Light Emitting Diode and Laser Diode emitters for fiber-optic applications are reviewed, and some advantages and shortcomings of each are considered. The phenomenon of modal noise is briefly explained. Both PIN and Avalanche photodetectors are reviewed and their performance parameters compared. Methods of data transmission over optical fiber are introduced. Principles of Wavelength, Frequency, and Time Division Multiplexing are briefly presented. The technology of fiber-optic sensors is briefly reviewed with basic principles introduced. The performance of a fiber-optic strain sensor is included as a practical example. 7 refs., 10 figs

  10. Optical Access Networks

    Science.gov (United States)

    Zheng, Jun; Ansari, Nirwan

    2005-01-01

    Call for Papers: Optical Access Networks Guest Editors Jun Zheng, University of Ottawa Nirwan Ansari, New Jersey Institute of Technology Submission Deadline: 1 June 2005 Background With the wide deployment of fiber-optic technology over the past two decades, we have witnessed a tremendous growth of bandwidth capacity in the backbone networks of today's telecommunications infrastructure. However, access networks, which cover the "last-mile" areas and serve numerous residential and small business users, have not been scaled up commensurately. The local subscriber lines for telephone and cable television are still using twisted pairs and coaxial cables. Most residential connections to the Internet are still through dial-up modems operating at a low speed on twisted pairs. As the demand for access bandwidth increases with emerging high-bandwidth applications, such as distance learning, high-definition television (HDTV), and video on demand (VoD), the last-mile access networks have become a bandwidth bottleneck in today's telecommunications infrastructure. To ease this bottleneck, it is imperative to provide sufficient bandwidth capacity in the access networks to open the bottleneck and thus present more opportunities for the provisioning of multiservices. Optical access solutions promise huge bandwidth to service providers and low-cost high-bandwidth services to end users and are therefore widely considered the technology of choice for next-generation access networks. To realize the vision of optical access networks, however, many key issues still need to be addressed, such as network architectures, signaling protocols, and implementation standards. The major challenges lie in the fact that an optical solution must be not only robust, scalable, and flexible, but also implemented at a low cost comparable to that of existing access solutions in order to increase the economic viability of many potential high-bandwidth applications. In recent years, optical access networks

  11. Optical Manipulation System Using a Plurality of Optical Traps

    DEFF Research Database (Denmark)

    2006-01-01

    The present invention relates to an optical manipulation system (10) for generation of a plurality of optical traps for manipulation of micro-objects including nano-objects using electromagnetic radiation forces in a micro-object manipulation volume (14), the system comprising a spatially modulat...

  12. Optically intraconnected computer employing dynamically reconfigurable holographic optical element

    Science.gov (United States)

    Bergman, Larry A. (Inventor)

    1992-01-01

    An optically intraconnected computer and a reconfigurable holographic optical element employed therein. The basic computer comprises a memory for holding a sequence of instructions to be executed; logic for accessing the instructions in sequence; logic for determining for each the instruction the function to be performed and the effective address thereof; a plurality of individual elements on a common support substrate optimized to perform certain logical sequences employed in executing the instructions; and, element selection logic connected to the logic determining the function to be performed for each the instruction for determining the class of each function and for causing the instruction to be executed by those the elements which perform those associated the logical sequences affecting the instruction execution in an optimum manner. In the optically intraconnected version, the element selection logic is adapted for transmitting and switching signals to the elements optically.

  13. UV-cured polymer optics

    Science.gov (United States)

    Piñón, Victor; Santiago, Freddie; Vogelsberg, Ashten; Davenport, Amelia; Cramer, Neil

    2017-10-01

    Although many optical-quality glass materials are available for use in optical systems, the range of polymeric materials is limited. Polymeric materials have some advantages over glass when it comes to large-scale manufacturing and production. In smaller scale systems, they offer a reduction in weight when compared to glass counterparts. This is especially important when designing optical systems meant to be carried by hand. We aimed to expand the availability of polymeric materials by exploring both crown-like and flint-like polymers. In addition, rapid and facile production was also a goal. By using UV-cured thiolene-based polymers, we were able to produce optical materials within seconds. This enabled the rapid screening of a variety of polymers from which we down-selected to produce optical flats and lenses. We will discuss problems with production and mitigation strategies in using UV-cured polymers for optical components. Using UV-cured polymers present a different set of problems than traditional injection-molded polymers, and these issues are discussed in detail. Using these produced optics, we integrated them into a modified direct view optical system, with the end goal being the development of drop-in replacements for glass components. This optical production strategy shows promise for use in lab-scale systems, where low-cost methods and flexibility are of paramount importance.

  14. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, Paul J.; Davis, Donald T.

    1994-01-01

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optic fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends.

  15. Reflective Optics for Microdiffraction

    International Nuclear Information System (INIS)

    Ice, G.E.

    2007-01-01

    Nondispersive optics are essential for emerging microdiffraction and nanobeam research. Here we describe extensions to traditional Kirkpatrick Baez optics required to develop nondispersive microdiffraction and nanoprobe optics with 1-10 nm spatial resolution

  16. Optical programmable metamaterials

    Science.gov (United States)

    Gong, Cheng; Zhang, Nan; Dai, Zijie; Liu, Weiwei

    2018-02-01

    We suggest and demonstrate the concept of optical programmable metamaterials which can configure the device's electromagnetic parameters by the programmable optical stimuli. In such metamaterials, the optical stimuli produced by a FPGA controlled light emitting diode array can switch or combine the resonance modes which are coupled in. As an example, an optical programmable metamaterial terahertz absorber is proposed. Each cell of the absorber integrates four meta-rings (asymmetric 1/4 rings) with photo-resistors connecting the critical gaps. The principle and design of the metamaterials are illustrated and the simulation results demonstrate the functionalities for programming the metamaterial absorber to change its bandwidth and resonance frequency.

  17. Optical geometry

    International Nuclear Information System (INIS)

    Robinson, I.; Trautman, A.

    1988-01-01

    The geometry of classical physics is Lorentzian; but weaker geometries are often more appropriate: null geodesics and electromagnetic fields, for example, are well known to be objects of conformal geometry. To deal with a single null congruence, or with the radiative electromagnetic fields associated with it, even less is needed: flag geometry for the first, optical geometry, with which this paper is chiefly concerned, for the second. The authors establish a natural one-to-one correspondence between optical geometries, considered locally, and three-dimensional Cauchy-Riemann structures. A number of Lorentzian geometries are shown to be equivalent from the optical point of view. For example the Goedel universe, the Taub-NUT metric and Hauser's twisting null solution have an optical geometry isomorphic to the one underlying the Robinson congruence in Minkowski space. The authors present general results on the problem of lifting a CR structure to a Lorentz manifold and, in particular, to Minkowski space; and exhibit the relevance of the deviation form to this problem

  18. All-optical virtual private network and ONUs communication in optical OFDM-based PON system.

    Science.gov (United States)

    Zhang, Chongfu; Huang, Jian; Chen, Chen; Qiu, Kun

    2011-11-21

    We propose and demonstrate a novel scheme, which enables all-optical virtual private network (VPN) and all-optical optical network units (ONUs) inter-communications in optical orthogonal frequency-division multiplexing-based passive optical network (OFDM-PON) system using the subcarrier bands allocation for the first time (to our knowledge). We consider the intra-VPN and inter-VPN communications which correspond to two different cases: VPN communication among ONUs in one group and in different groups. The proposed scheme can provide the enhanced security and a more flexible configuration for VPN users compared to the VPN in WDM-PON or TDM-PON systems. The all-optical VPN and inter-ONU communications at 10-Gbit/s with 16 quadrature amplitude modulation (16 QAM) for the proposed optical OFDM-PON system are demonstrated. These results verify that the proposed scheme is feasible. © 2011 Optical Society of America

  19. All-optical pulse data generation in a semiconductor optical amplifier gain controlled by a reshaped optical clock injection

    Science.gov (United States)

    Lin, Gong-Ru; Chang, Yung-Cheng; Yu, Kun-Chieh

    2006-05-01

    Wavelength-maintained all-optical pulse data pattern transformation based on a modified cross-gain-modulation architecture in a strongly gain-depleted semiconductor optical amplifier (SOA) is investigated. Under a backward dark-optical-comb injection with 70% duty-cycle reshaping from the received data clock at 10GHz, the incoming optical data stream is transformed into a pulse data stream with duty cycle, rms timing jitter, and conversion gain of 15%, 4ps, and 3dB, respectively. The high-pass filtering effect of the gain-saturated SOA greatly improves the extinction ratio of data stream by 8dB and reduces its bit error rate to 10-12 at -18dBm.

  20. Fractal vector optical fields.

    Science.gov (United States)

    Pan, Yue; Gao, Xu-Zhen; Cai, Meng-Qiang; Zhang, Guan-Lin; Li, Yongnan; Tu, Chenghou; Wang, Hui-Tian

    2016-07-15

    We introduce the concept of a fractal, which provides an alternative approach for flexibly engineering the optical fields and their focal fields. We propose, design, and create a new family of optical fields-fractal vector optical fields, which build a bridge between the fractal and vector optical fields. The fractal vector optical fields have polarization states exhibiting fractal geometry, and may also involve the phase and/or amplitude simultaneously. The results reveal that the focal fields exhibit self-similarity, and the hierarchy of the fractal has the "weeding" role. The fractal can be used to engineer the focal field.

  1. 50 years of nonlinear optics

    International Nuclear Information System (INIS)

    Shen Yuanrang

    2011-01-01

    This article presents a brief introduction to the birth and early investigations of nonlinear optics, such as second harmonic generation,sum and difference frequency generation, stimulated Raman scattering,and self-action of light etc. Several important research achievements and applications of nonlinear optics are presented as well, including nonlinear optical spectroscopy, phase conjugation and adaptive optics, coherent nonlinear optics, and high-order harmonic generation. In the end, current and future research topics in nonlinear optics are summarized. (authors)

  2. Accuracies Of Optical Processors For Adaptive Optics

    Science.gov (United States)

    Downie, John D.; Goodman, Joseph W.

    1992-01-01

    Paper presents analysis of accuracies and requirements concerning accuracies of optical linear-algebra processors (OLAP's) in adaptive-optics imaging systems. Much faster than digital electronic processor and eliminate some residual distortion. Question whether errors introduced by analog processing of OLAP overcome advantage of greater speed. Paper addresses issue by presenting estimate of accuracy required in general OLAP that yields smaller average residual aberration of wave front than digital electronic processor computing at given speed.

  3. Optical Computers and Space Technology

    Science.gov (United States)

    Abdeldayem, Hossin A.; Frazier, Donald O.; Penn, Benjamin; Paley, Mark S.; Witherow, William K.; Banks, Curtis; Hicks, Rosilen; Shields, Angela

    1995-01-01

    The rapidly increasing demand for greater speed and efficiency on the information superhighway requires significant improvements over conventional electronic logic circuits. Optical interconnections and optical integrated circuits are strong candidates to provide the way out of the extreme limitations imposed on the growth of speed and complexity of nowadays computations by the conventional electronic logic circuits. The new optical technology has increased the demand for high quality optical materials. NASA's recent involvement in processing optical materials in space has demonstrated that a new and unique class of high quality optical materials are processible in a microgravity environment. Microgravity processing can induce improved orders in these materials and could have a significant impact on the development of optical computers. We will discuss NASA's role in processing these materials and report on some of the associated nonlinear optical properties which are quite useful for optical computers technology.

  4. Phase-Modulated Optical Communication Systems

    CERN Document Server

    Ho, Keang-Po

    2005-01-01

    Fiber-optic communication systems have revolutionized our telecommunication infrastructures – currently, almost all telephone land-line, cellular, and internet communications must travel via some form of optical fibers. In these transmission systems, neither the phase nor frequency of the optical signal carries information – only the intensity of the signal is used. To transmit more information in a single optical carrier, the phase of the optical carrier must be explored. As a result, there is renewed interest in phase-modulated optical communications, mainly in direct-detection DPSK signals for long-haul optical communication systems. When optical amplifiers are used to maintain certain signal level among the fiber link, the system is limited by amplifier noises and fiber nonlinearities. Phase-Modulated Optical Communication Systems surveys this newly popular area, covering the following topics: The transmitter and receiver for phase-modulated coherent lightwave systems Method for performance analysis o...

  5. The optical system of the proposed Chinese 12-m optical/infrared telescope

    Science.gov (United States)

    Su, Ding-qiang; Liang, Ming; Yuan, Xiangyan; Bai, Hua; Cui, Xiangqun

    2017-08-01

    The lack of a large-aperture optical/infrared telescope has seriously affected the development of astronomy in China. In 2016, the authors published their concept study and suggestions for a 12-m telescope optical system. This article presents the authors' further research and some new results. Considering that this telescope should be a general-purpose telescope for a wide range of scientific goals and could be used for frontier scientific research in the future, the authors studied and designed a variety of 12-m telescope optical systems for comparison and final decision-making. In general, we still adopt our previous configuration, but the Nasmyth and prime-focus corrector systems have been greatly improved. In this article, the adaptive optics is given special attention. Ground-layer adaptive optics (GLAO) is adopted. It has a 14-arcmin field of view. The secondary mirror is used as the adaptive optical deformable mirror. Obviously, not all the optical systems in this telescope configuration will be used or constructed at the same stage. Some will be for the future and some are meant for research rather than for construction.

  6. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Directory of Open Access Journals (Sweden)

    Ahmed Almazroa

    2015-01-01

    Full Text Available Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed.

  7. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Science.gov (United States)

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  8. Optical Computing

    Indian Academy of Sciences (India)

    Other advantages of optics include low manufacturing costs, immunity to ... It is now possible to control atoms by trapping single photons in small, .... cement, and optical spectrum analyzers. ... risk of noise is further reduced, as light is immune to electro- ..... mode of operation including management of large multimedia.

  9. Intelligent Optics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Intelligent Optics Laboratory supports sophisticated investigations on adaptive and nonlinear optics; advancedimaging and image processing; ground-to-ground and...

  10. A metropolitan optical network with support for multicasting in the optical domain

    NARCIS (Netherlands)

    Dey, D.; Koonen, A.M.J.; Bochove, van A.C.; Geuzebroek, D.; Salvador, M.R.; Berghmans, F.; Thienpont, H.; Danckaert, J.; Desmet, L.

    2001-01-01

    We present the FLAMINGO1 network architecture, an all-optical wavelength-and-timeslotted Metropolitan Optical Network based on a multiple-ring topology. A couple of important aspects of this architecture include all-optical packet switching at intermediate nodes on a ring and the ability to put IP

  11. A Metropolitan Optical Network with support for multicasting in the optical domain

    NARCIS (Netherlands)

    Dey, D.; Koonen, A.M.J.; van Bochove, A.C.; Geuzebroek, D.H.; Salvador, M.R.; Thienpont, H.; Berghmans, F.; Danckaert, J.; Desmet, L.

    2001-01-01

    We present the FLAMINGO1 network architecture, an all-optical wavelength-and-timeslotted Metropolitan Optical Network based on a multiple-ring topology. A couple of important aspects of this architecture include all-optical packet switching at intermediate nodes on a ring and the ability to put IP

  12. Orbitopterional Approach for the Resection of a Suprasellar Craniopharyngioma: Adapting the Strategy to the Microsurgical and Pathologic Anatomy.

    Science.gov (United States)

    Nguyen, Vincent; Basma, Jaafar; Klimo, Paul; Sorenson, Jeffrey; Michael, L Madison

    2018-04-01

    Objectives  To describe the orbitopterional approach for the resection of a suprasellar craniopharyngioma with emphasis on the microsurgical and pathological anatomy of such lesions. Design  After completing the orbitopterional craniotomy in one piece including a supraorbital ridge osteotomy, the Sylvian fissure was split in a distal to proximal direction. The ipsilateral optic nerve and internal carotid artery were identified. Establishing a corridor to the tumor through both the opticocarotid and optic cisterns allowed for a wide angle of attack. Using both corridors, a microsurgical gross total resection was achieved. A radical resection required transection of the stalk at the level of the hypothalamus. Photographs of the region are borrowed from Dr Rhoton's laboratory to illustrate the microsurgical anatomy. Understanding the cisternal and topographic relationships of the optic nerve, optic chiasm, and internal carotid artery is critical to achieving gross total resection while preserving normal anatomy. Participants  The surgery was performed by the senior author assisted by Dr. Jaafar Basma. The video was edited by Dr. Vincent Nguyen. Outcome Measures  Outcome was assessed with extent of resection and postoperative visual function. Results  A gross total resection of the tumor was achieved. The patient had resolution of her bitemporal hemianopsia. She had diabetes insipidus with normal anterior pituitary function. Conclusions  Understanding the microsurgical anatomy of the suprasellar region and the pathological anatomy of craniopharyngiomas is necessary to achieve a good resection of these tumors. The orbitopterional approach provides the appropriate access for such endeavor. The link to the video can be found at: https://youtu.be/Be6dtYIGqfs .

  13. Radiative properties of optical board embedded with optical black holes

    International Nuclear Information System (INIS)

    Qiu, J.; Liu, L.H.; Hsu, P.-F.

    2011-01-01

    Unique radiative properties, such as wavelength-selective transmission or absorption, have been intensively studied. Historically, geometries for wavelength-selective of light absorption were developed based on metallic periodical structures, which were only applied in the case of TM wave incidence due to the excitation of surface plasmons. In this paper, we develop an alternative approach to selective wavelength of light absorption (both TE and TM waves), based on an optical board periodical embedded with optical black holes. Numerical work was carried out to study such structure's radiative properties within the wavelength range of 1-100 μm. The electromagnetic wave transmission through such a structure is predicted by solving Maxwell's equations using the finite-difference time-domain (FDTD) method. Spectral absorptance varies with the period of optical black holes. When the incidence wavelength is much larger than the inner core radius, most of the light energy will be transmitted through the inner core. Otherwise, the energy will be mainly absorbed. Numerical results of the radiative properties of the optical board with different incidence wavelengths are also obtained. The effect of the oblique incidence wave is investigated. This study helps us gain a better understanding of the radiative properties of an optical board embedded with optical black holes and develop an alternative approach to selective light absorption.

  14. Using spectral-domain optical coherence tomography to detect optic neuropathy in patients with craniosynostosis.

    Science.gov (United States)

    Dagi, Linda R; Tiedemann, Laura M; Heidary, Gena; Robson, Caroline D; Hall, Amber M; Zurakowski, David

    2014-12-01

    Detecting and monitoring optic neuropathy in patients with craniosynostosis is a clinical challenge due to limited cooperation, and subjective measures of visual function. The purpose of this study was to appraise the correlation of peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral-domain ocular coherence tomography (SD-OCT) with indication of optic neuropathy based on fundus examination. The medical records of all patients with craniosynostosis presenting for ophthalmic evaluation during 2013 were retrospectively reviewed. The following data were abstracted from the record: diagnosis, historical evidence of elevated intracranial pressure, current ophthalmic evaluation and visual field results, and current peripapillary RNFL thickness. A total of 54 patients were included (mean age, 10.6 years [range, 2.4-33.8 years]). Thirteen (24%) had evidence of optic neuropathy based on current fundus examination. Of these, 10 (77%) demonstrated either peripapillary RNFL elevation and papilledema or depression with optic atrophy. Sensitivity for detecting optic atrophy was 88%; for papilledema, 60%; and for either form of optic neuropathy, 77%. Specificity was 94%, 90%, and 83%, respectively. Kappa agreement was substantial for optic atrophy (κ = 0.73) and moderate for papilledema (κ = 0.39) and for either form of optic neuropathy (κ = 0.54). Logistic regression indicated that peripapillary RNFL thickness was predictive of optic neuropathy (P optic neuropathy than visual field testing (likelihood ratio = 10.02; P = 0.002). Sensitivity and specificity of logMAR visual acuity in detecting optic neuropathy were 15% and 95%, respectively. Peripapillary RNFL thickness measured by SD-OCT provides adjunctive evidence for identifying optic neuropathy in patients with craniosynostosis and appears more sensitive at detecting optic atrophy than papilledema. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by

  15. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  16. Coding for optical channels

    CERN Document Server

    Djordjevic, Ivan; Vasic, Bane

    2010-01-01

    This unique book provides a coherent and comprehensive introduction to the fundamentals of optical communications, signal processing and coding for optical channels. It is the first to integrate the fundamentals of coding theory and optical communication.

  17. Modeling of semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Mørk, Jesper; Bischoff, Svend; Berg, Tommy Winther

    We discuss the modelling of semiconductor optical amplifiers with emphasis on their high-speed properties. Applications in linear amplification as well as ultrafast optical signal processing are reviewed. Finally, the possible role of quantum-dot based optical amplifiers is discussed.......We discuss the modelling of semiconductor optical amplifiers with emphasis on their high-speed properties. Applications in linear amplification as well as ultrafast optical signal processing are reviewed. Finally, the possible role of quantum-dot based optical amplifiers is discussed....

  18. Improved Optical Fiber Chemical Sensors

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1994-01-01

    Calculations, based on exact theory of optical fiber, have shown how to increase optical efficiency sensitivity of active-core, step-index-profile optical-fiber fluorosensor. Calculations result of efforts to improve efficiency of optical-fiber chemical sensor of previous concept described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525). Optical fiber chemical detector of enhanced sensitivity made in several configurations. Portion of fluorescence or chemiluminescence generated in core, and launched directly into bound electromagnetic modes that propagate along core to photodetector.

  19. Optical design of an athermalised dual field of view step zoom optical system in MWIR

    Science.gov (United States)

    Kucukcelebi, Doruk

    2017-08-01

    In this paper, the optical design of an athermalised dual field of view step zoom optical system in MWIR (3.7μm - 4.8μm) is described. The dual field of view infrared optical system is designed based on the principle of passive athermalization method not only to achieve athermal optical system but also to keep the high image quality within the working temperature between -40°C and +60°C. The infrared optical system used in this study had a 320 pixel x 256 pixel resolution, 20μm pixel pitch size cooled MWIR focal plane array detector. In this study, the step zoom mechanism, which has the axial motion due to consisting of a lens group, is considered to simplify mechanical structure. The optical design was based on moving a single lens along the optical axis for changing the optical system's field of view not only to reduce the number of moving parts but also to athermalize for the optical system. The optical design began with an optimization process using paraxial optics when first-order optics parameters are determined. During the optimization process, in order to reduce aberrations, such as coma, astigmatism, spherical and chromatic aberrations, aspherical surfaces were used. As a result, athermalised dual field of view step zoom optical design is proposed and the performance of the design using proposed method was verified by providing the focus shifts, spot diagrams and MTF analyzes' plots.

  20. Optical Characterization of Doped Thermoplastic and Thermosetting Polymer-Optical-Fibers

    Directory of Open Access Journals (Sweden)

    Igor Ayesta

    2017-03-01

    Full Text Available The emission properties of a graded-index thermoplastic polymer optical fiber and a step-index thermosetting one, both doped with rhodamine 6G, have been studied. The work includes a detailed analysis of the amplified spontaneous emission together with a study of the optical gains and losses of the fibers. The photostability of the emission of both types of fibers has also been investigated. Comparisons between the results of both doped polymer optical fibers are presented and discussed.

  1. Quantum optics for experimentalists

    CERN Document Server

    Ou, Zhe-Yu Jeff

    2017-01-01

    This book on quantum optics is from the point of view of an experimentalist. It approaches the theory of quantum optics with the language of optical modes of classical wave theory, with which experimentalists are most familiar.

  2. Optically Anomalous Crystals

    CERN Document Server

    Shtukenberg, Alexander; Kahr, Bart

    2007-01-01

    Optical anomalies in crystals are puzzles that collectively constituted the greatest unsolved problems in crystallography in the 19th Century. The most common anomaly is a discrepancy between a crystal’s symmetry as determined by its shape or by X-ray analysis, and that determined by monitoring the polarization state of traversing light. These discrepancies were perceived as a great impediment to the development of the sciences of crystals on the basis of Curie’s Symmetry Principle, the grand organizing idea in the physical sciences to emerge in the latter half of the 19th Century. Optically Anomalous Crystals begins with an historical introduction covering the contributions of Brewster, Biot, Mallard, Brauns, Tamman, and many other distinguished crystallographers. From this follows a tutorial in crystal optics. Further chapters discuss the two main mechanisms of optical dissymmetry: 1. the piezo-optic effect, and 2. the kinetic ordering of atoms. The text then tackles complex, inhomogeneous crystals, and...

  3. Quantum optics

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, P D [University of Queensland, St. Lucia, QLD (Australia).Physics Department

    1999-07-01

    Full text: Quantum optics in Australia has been an active research field for some years. I shall focus on recent developments in quantum and atom optics. Generally, the field as a whole is becoming more and more diverse, as technological developments drive experiments into new areas, and theorists either attempt to explain the new features, or else develop models for even more exotic ideas. The recent developments include quantum solitons, quantum computing, Bose-Einstein condensation, atom lasers, quantum cryptography, and novel tests of quantum mechanics. The talk will briefly cover current progress and outstanding problems in each of these areas. Copyright (1999) Australian Optical Society.

  4. Development of optical sciences in Poland

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2013-10-01

    Research and technical communities for optics, photonics and optoelectronics is grouped in this country in several organizations and institutions. These are: Photonics Society of Poland (PSP), Polish Committee of Optoelectronics of SEP, Photonics Section of KEiT PAN, Laser Club at WAT, and Optics Section of PTF. Each of these communities keeps slightly different specificity. PSP publishes a quarterly journal Photonics Letters of Poland, stimulates international cooperation, and organizes conferences during Industrial Fairs on Innovativeness. PKOpto SEP organizes didactic diploma competitions in optoelectronics. KEiT PAN takes patronage over national conferences in laser technology, optical fiber technology and communications, and photonics applications. SO-PTF has recently taken a decision to organize a cyclic event "Polish Optical Conference". The third edition of this conference PKO'2013 was held in Sandomierz on 30.06-04.07.2013. The conference scientific and technical topics include: quantum and nonlinear optics, photon physics, optic and technology of lasers and other sources of coherent radiation, optoelectronics, optical integrated circuits, optical fibers, medical optics, instrumental optics, optical spectroscopy, optical metrology, new optical materials, applications of optics, teaching in optics. This paper reviews chosen works presented during the III Polish Optical Conference (PKO'2013), representing the research efforts at different national institutions.

  5. Fiber optic strain measurements using an optically-active polymer

    Science.gov (United States)

    Buckley, Leonard J.; Neumeister, Gary C.

    1992-03-01

    A study encompassing the use of an optically-active polymer as the strain-sensing medium in an organic matrix composite was performed. Several compounds were synthesized for use as the inner cladding material for silica fiber-optic cores. These materials include a diacetylene containing polyamide. It is possible to dynamically modify the optical properties of these materials through changes in applied strain or temperature. By doing so the characteristic absorption in the visible is reversibly shifted to a higher energy state. The polymer-coated fiber-optic cores were initially studied in epoxy resin. Additionally, one of the polyamide/diacetylene polymers was studied in a spin-fiber form consisting of 15 micron filaments assembled in multifilament tows. The most promising configuration and materials were then investigated further by embedding in graphite/epoxy composite laminates. In each case the shift in the visible absorption peak was monitored as a function of applied mechanical strain.

  6. Optical Axis Identification Technique for Free Space Optics Transmission

    Directory of Open Access Journals (Sweden)

    Yuki Tashiro

    2017-07-01

    Full Text Available This paper describes optical axis adjustment technique for an active free space optics transmission system. This system precisely controls the direction of a collimated thin laser beam using a motor driven laser emitting mechanism and positioning photodiodes. Before beginning laser beam feedback control, it is required to guide the laser beam within the range of the positioning photodiodes for initial laser beam alignment. This paper proposes an arrival position presumption method of laser beam traveling along the long distance from transmitter. A positioning sensor containing several photodiodes measures laser luminescence distribution, and analytically calculates the optical axis of laser beam according to the modified Gaussian beam optics based on four or five distributed local intensity of laser luminescence. Experiments are conducted to evaluate the accuracy of the presumption, and results reveal that the method is effective in leading the laser beam onto a distant receiver.

  7. Optical metamaterials with quasicrystalline symmetry: symmetry-induced optical isotropy

    International Nuclear Information System (INIS)

    Kruk, S.S.; Decker, M.; Helgert, Ch.; Neshev, D.N.; Kivshar, Y.S.; Staude, I.; Powell, D.A.; Pertsch, Th.; Menzel, Ch.; Helgert, Ch.; Etrich, Ch.; Rockstuhl, C.; Menzel, Ch.

    2013-01-01

    Taking advantage of symmetry considerations, we have analyzed the potential of various metamaterials to affect the polarization state of light upon oblique illumination. We have shown that depending on the angle of illumination, metamaterials are able to support specific polarization states. The presented methodology that using ellipticity and circular dichroism, provides an unambiguous language for discussing the impact of the inherent symmetry of the metamaterial lattices on their far-field response. Our findings allow the quantification analysis of the impact of inter-element coupling and lattice symmetry on the optical properties of metamaterials, and to separate this contribution from the response associated with a single meta-atom. In addition, we have studied the concept of optical quasicrystalline metamaterials, revealing that the absence of translational symmetry (periodicity) of quasicrystalline metamaterials causes an isotropic optical response, while the long-range positional order preserves the resonance properties. Our findings constitute an important step towards the design of optically isotropic metamaterials and metasurfaces. (authors)

  8. Remote nano-optical beam focusing lens by illusion optics

    Science.gov (United States)

    Margousi, David; Shoorian, Hamed Reza

    2014-08-01

    In this paper, as a new application of illusion optics, a nano-optical plasmonic focusing lens structure is proposed to manipulate the light remotely by employing illusion optics theory. Plasmonic nano-optic lenses that enable super-focusing beyond the diffraction limit have been proposed as an alternative to the conventional dielectric-based refractive lenses. In the presence of an illusion device, the electromagnetic plane-waves can penetrate into a metal layer and a clear focus appears. When the illusion device is removed, waves are blocked to transmit through the metal wall. In comparison with conventional methods, our proposed method avoids any physical changes or damages in the original structure. The proposed structure can be realized by isotropic layered materials, using effective medium theory. The special feature of the proposed structure and the device concepts introduced in this work gives it an opportunity to be used as a flexible element in ultrahigh nano-scale integrated circuits for miniaturization and tuning purposes.

  9. OPTICAL FIBRES AND FIBREOPTIC SENSORS: Polarisation reflectometry of anisotropic optical fibres

    Science.gov (United States)

    Konstantinov, Yurii A.; Kryukov, Igor'I.; Pervadchuk, Vladimir P.; Toroshin, Andrei Yu

    2009-11-01

    Anisotropic, polarisation-maintaining fibres have been studied using a reflectometer and integrated optic polariser. Linearly polarised pulses were launched into the fibre under test at different angles between their plane of polarisation and the main optical axis of the fibre. A special procedure for the correlation analysis of these reflectograms is developed to enhance the reliability of the information about the longitudinal optical uniformity ofanisotropic fibres.

  10. Advanced optical instruments technology

    Science.gov (United States)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  11. Dynamic optical arbitrary waveform shaping based on cascaded optical modulators of single FBG.

    Science.gov (United States)

    Chen, Jingyuan; Li, Peili

    2015-08-10

    A dynamic optical arbitrary waveform generation (O-AWG) with amplitude and phase independently controlled in optical modulators of single fiber Bragg Grating (FBG) has been proposed. This novel scheme consists of several optical modulators. In the optical modulator (O-MOD), a uniform FBG is used to filter spectral component of the input signal. The amplitude is controlled by fiber stretcher (FS) in Mach-Zehnder interference (MZI) structure through interference of two MZI arms. The phase is manipulated via the second FS in the optical modulator. This scheme is investigated by simulation. Consequently, optical pulse trains with different waveforms as well as pulse trains with nonuniform pulse intensity, pulse spacing and pulse width within each period are obtained through FSs adjustment to alter the phase shifts of signal in each O-MOD.

  12. Experimental and theoretical investigation of semiconductor optical amplifier (SOA) based all-optical switches

    DEFF Research Database (Denmark)

    Nielsen, Mads Lønstrup

    2004-01-01

    This thesis analyzes semiconductor optical amplifier (SOA) based all-optical switches experimentally and through numerical simulations. These devices are candidates for optical signal processing functionalities such as wavelength conversion, regeneration, and logic processing in future transparent......, consisting of an SOA and an asymmetric MZI filter, is analyzed in the small-signal regime, and the obtainable modulation bandwidth is expressed analytically. A new optical spectrum approach to small signal analysis is introduced, and is used to assess the bandwidth enhancing effect of different optical...... filters, as well the impact of the filter phase response. Experiments at 40 Gb/s verify the predictions of the small-signal analysis. Wavelength conversion is demonstrated experimentally at 40 Gb/s using a simple filtering-assisted scheme with an ultra-low optical switching energy, and up to 80 Gb...

  13. Improving fiber-optic laser beam delivery by incorporating GRADIUM optics

    International Nuclear Information System (INIS)

    Hunter, B.V.; Leong, K.H.

    1997-01-01

    The performance of a fiber-optic laser beam delivery system strongly depends on the fiber and the optics used to image the fiber face on the workpiece. We have compared off-the-shelf homogenous (BK7) and GRADIUM (axial-gradient) singlets to determine what improvement the GRADIUM offers in practice to the typical laser user. The realized benefit for this application, although significant, is much smaller than would be realized by a conventional imaging application. The figure of merit for laser-based materials processing is the 86% energy-enclosure radius, which is not directly supported by commerical ray-tracing software. Therefore empirical rules of thumb are presented to understand when GRADIUM (or any other well-corrected optics) will yield meaningful improvement to the beam delivery system. copyright 1997 Optical Society of America

  14. All-Optical Network Subsystems Using Integrated SOA-Based Optical Gates and Flip-Flops for Label-Swapped Netorks

    DEFF Research Database (Denmark)

    Seoane, Jorge; Holm-Nielsen, Pablo Villanueva; Kehayas, E.

    2006-01-01

    In this letter, we demonstrate that all-optical network subsystems, offering intelligence in the optical layer, can be constructed by functional integration of integrated all-optical logic gates and flip-flops. In this context, we show 10-Gb/s all-optical 2-bit label address recognition......-level advantages of these all-optical subsystems combined with their realization with compact integrated devices, suggest that they are strong candidates for future packet/label switched optical networks....... by interconnecting two optical gates that perform xor operation on incoming optical labels. We also demonstrate 40-Gb/s all-optical wavelength-switching through an optically controlled wavelength converter, consisting of an integrated flip-flop prototype device driven by an integrated optical gate. The system...

  15. Optical high-performance computing: introduction to the JOSA A and Applied Optics feature.

    Science.gov (United States)

    Caulfield, H John; Dolev, Shlomi; Green, William M J

    2009-08-01

    The feature issues in both Applied Optics and the Journal of the Optical Society of America A focus on topics of immediate relevance to the community working in the area of optical high-performance computing.

  16. Optical fiber switch

    Science.gov (United States)

    Early, James W.; Lester, Charles S.

    2002-01-01

    Optical fiber switches operated by electrical activation of at least one laser light modulator through which laser light is directed into at least one polarizer are used for the sequential transport of laser light from a single laser into a plurality of optical fibers. In one embodiment of the invention, laser light from a single excitation laser is sequentially transported to a plurality of optical fibers which in turn transport the laser light to separate individual remotely located laser fuel ignitors. The invention can be operated electro-optically with no need for any mechanical or moving parts, or, alternatively, can be operated electro-mechanically. The invention can be used to switch either pulsed or continuous wave laser light.

  17. Optical fiber communications

    CERN Document Server

    Keiser, Gerd

    2008-01-01

    The fourth edition of this popular text and reference book presents the fundamental principles for understanding and applying optical fiber technology to sophisticated modern telecommunication systems. Optical-fiber-based telecommunication networks have become a major information-transmission-system, with high capacity links encircling the globe in both terrestrial and undersea installations. Numerous passive and active optical devices within these links perform complex transmission and networking functions in the optical domain, such as signal amplification, restoration, routing, and switching. Along with the need to understand the functions of these devices comes the necessity to measure both component and network performance, and to model and stimulate the complex behavior of reliable high-capacity networks.

  18. All-optical signal processing of OTDM and OFDM signals based on time-domain optical fourier transformation

    DEFF Research Database (Denmark)

    Galili, Michael; Guan, Pengyu; Lillieholm, Mads

    2017-01-01

    In the talk, we will review recent work on optical signal processing based on time lenses. Various applications of optical Fourier transformation for optical communications will be discussed.......In the talk, we will review recent work on optical signal processing based on time lenses. Various applications of optical Fourier transformation for optical communications will be discussed....

  19. Magneto-optic properties and optical parameter of thin MnCo films

    Directory of Open Access Journals (Sweden)

    E Attaran Kakhki

    2009-09-01

    Full Text Available Having precise hysterics loop of thin ferroelectric and ferromagnetic layers for optical switching and optical storages are important. A hysterieses loop can be achieved from a phenomenon call the magneto-optic effect. The magneto-optic effect is the rotation of a linear polarized electromagnetic wave propagated through a ferromagnetic medium. When light is transmitted through a layer of magnetic material the result is called the Faraday effects and in the reflection mode Kerr effect. In the present work we prepared a thin layer of MnxCo3-xO4 (0≤ x ≤ 1 and a binary form of MnO/Co3O4 by the spray pyrolysis method. The films have been characterized by a special set up of magneto-optic hysterics loop plotter containing a polarized He- Ne laser beam and a special electronic circuit. Faraday rotation were measured for these films by hysterics loop plotter and their optical properties were also obtained by spatial software designed for this purpose according to Swane Poel theoretical method. The measurements show that the samples at diluted Mn study has are ferromagnetic and the magneto-optic rotation show a good enhance respect to the single Co layers. Also, the study has shown that the MnCo oxide layer have two different energy gaps and by increasing of Mn this energy decreases and fall to 0.13 eV.

  20. Reciprocity in optics

    International Nuclear Information System (INIS)

    Potton, R J

    2004-01-01

    The application of reciprocity principles in optics has a long history that goes back to Stokes, Lorentz, Helmholtz and others. Moreover, optical applications need to be seen in the context of applications of reciprocity in particle scattering, acoustics, seismology and the solution of inverse problems, generally. In some of these other fields vector wave propagation is, as it is in optics, of the essence. For this reason the simplified approach to light wave polarization developed by, and named for, Jones is explored initially to see how and to what extent it encompasses reciprocity. The characteristic matrix of a uniform dielectric layer, used in the analysis of interference filters and mirrors, is reciprocal except when the layer is magneto-optical. The way in which the reciprocal nature of a characteristic matrix can be recognized is discussed next. After this, work on the influence of more realistic attributes of a dielectric stack on reciprocity is reviewed. Some of the numerous technological applications of magneto-optic non-reciprocal media are identified and the potential of a new class of non-reciprocal components is briefly introduced. Finally, the extension of the classical reciprocity concept to systems containing components that have nonlinear optical response is briefly mentioned

  1. Progress in linear optics, non-linear optics and surface alignment of liquid crystals

    Science.gov (United States)

    Ong, H. L.; Meyer, R. B.; Hurd, A. J.; Karn, A. J.; Arakelian, S. M.; Shen, Y. R.; Sanda, P. N.; Dove, D. B.; Jansen, S. A.; Hoffmann, R.

    We first discuss the progress in linear optics, in particular, the formulation and application of geometrical-optics approximation and its generalization. We then discuss the progress in non-linear optics, in particular, the enhancement of a first-order Freedericksz transition and intrinsic optical bistability in homeotropic and parallel oriented nematic liquid crystal cells. Finally, we discuss the liquid crystal alignment and surface effects on field-induced Freedericksz transition.

  2. Johannes Vermeer and Tom Gouws: textual discourse through pen ...

    African Journals Online (AJOL)

    Poems such as 'ars poetica' and 'die kantklosser' will be read as speaking paintings of visual texts and visual writing through which an exceptional merger of pen and brush come into being. Keywords: iconicity, tipography, cohesion, visual text, ars poetica, syntactic chiasm, texture, canto. Journal for Language Teaching Vol ...

  3. Optimisation of optical receiver for 10 Gbit/s optical duobinary transmission system

    DEFF Research Database (Denmark)

    Zheng, Xueyan; Liu, Fenghai; Jeppesen, Palle

    2001-01-01

    Optimisation of a receiver for an optical duobinary signal is studied numerically. It is shown that a conventional receiver is not optimum neither when a DCF is used before the receiver nor without a DCF being used. The optimum receiver for an optical duobinary system is identified.......Optimisation of a receiver for an optical duobinary signal is studied numerically. It is shown that a conventional receiver is not optimum neither when a DCF is used before the receiver nor without a DCF being used. The optimum receiver for an optical duobinary system is identified....

  4. Field guide to nonlinear optics

    CERN Document Server

    Powers, Peter E

    2013-01-01

    Optomechanics is a field of mechanics that addresses the specific design challenges associated with optical systems. This [i]Field Guide [/i]describes how to mount optical components, as well as how to analyze a given design. It is intended for practicing optical and mechanical engineers whose work requires knowledge in both optics and mechanics. This Field Guide is designed for those looking for a condensed and concise source of key concepts, equations, and techniques for nonlinear optics. Topics covered include technologically important effects, recent developments in nonlinear optics

  5. Optics in the United kingdom.

    Science.gov (United States)

    Ditchburn, R W

    1969-10-01

    Optics is interpreted to include x-ray optics, electronic optics, and short wave radiooptics as well as the more conventional visible, uv, and ir optics. Recent work in Britain on x-ray optics (applied to molecular biology), on scanning electron microscopy, and in radioastronomy (discovery of pulsars) is mentioned. In the optics of the visible and ir there is an increasing interest in over-all systems design. .The formation of large industrial units capable of carrying through major design program, requiring advanced mechanical and electronic design associated with new lens systems, is welcomed.

  6. Autofluorescence and spectral-domain optical coherence tomography of optic disk melanocytoma.

    Science.gov (United States)

    Guerra, Ricardo Luz Leitão; Marback, Eduardo Ferrari; Silva, Igor Sandes Pessoa da; Maia Junior, Otacílio de Oliveira; Marback, Roberto Lorens

    2014-01-01

    The authors report fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (OCT) findings of two consecutive patients who presented with optic disk melanocytoma (ODM). A retrospective study was performed by reviewing medical records and ophthalmic imaging examinations. Optical coherence tomography findings were sloped and brightly reflective anterior tumor surface, adjacent retinal desorganization and abrupt posterior optical shadowing. Vitreous seeds were found in one patient. Fundus autofluorescence revealed outstanding hypoautofluorescence at the tumor area and isoautofluorescence at the remaining retina. Optical coherence tomography findings of the reported cases are consistent with those reported in the reviewed literature. Fundus autofluorescence has been used in the assessment of choroidal melanocytic tumors, but not yet in melanocytomas. We assume that this is the first report of these findings and believe that when its pattern has become clearly defined, fundus autofluorescence will be a useful tool to avoid misdiagnosis in suspicious cases and for follow-up.

  7. Autofluorescence and spectral-domain optical coherence tomography of optic disk melanocytoma

    Directory of Open Access Journals (Sweden)

    Ricardo Luz Leitão Guerra

    2014-12-01

    Full Text Available The authors report fundus autofluorescence (FAF and spectral-domain optical coherence tomography (OCT findings of two consecutive patients who presented with optic disk melanocytoma (ODM. A retrospective study was performed by reviewing medical records and ophthalmic imaging examinations. Optical coherence tomography findings were sloped and brightly reflective anterior tumor surface, adjacent retinal desorganization and abrupt posterior optical shadowing. Vitreous seeds were found in one patient. Fundus autofluorescence revealed outstanding hypoautofluorescence at the tumor area and isoautofluorescence at the remaining retina. Optical coherence tomography findings of the reported cases are consistent with those reported in the reviewed literature. Fundus autofluorescence has been used in the assessment of choroidal melanocytic tumors, but not yet in melanocytomas. We assume that this is the first report of these findings and believe that when its pattern has become clearly defined, fundus autofluorescence will be a useful tool to avoid misdiagnosis in suspicious cases and for follow-up.

  8. Ubiquitous overexpression of a transgene encoding the extracellular portion of the Drosophila roughest-irregular chiasm C protein induces early embryonic lethality.

    Science.gov (United States)

    Moda, L; Machado, R C; Ramos, R G

    2000-09-01

    The cell adhesion molecule Rst-irreC is a transmembrane glycoprotein of the immunoglobulin superfamily involved in several important developmental processes in Drosophila, including axonal pathfinding in the optic lobe and programmed cell death and pigment cell differentiation in the pupal retina. As an initial step towards the "in vivo" functional analysis of this protein we have generated transgenic fly stocks carrying a truncated cDNA construct encoding only the extracellular domain of Rst-IrreC under the transcriptional control of the heat shock inducible promoter hsp70. We show that heat-shocking embryos bearing the transgene during the first 8hs of development lead to a 3-4 fold reduction in their viability compared to wild type controls. The embryonic lethality can already be produced by applying the heat pulse in the first 3hs of embryonic development, does not seem to be suppressed in the absence of wildtype product and is progressively reduced as the heat treatment is applied later in embryogenesis. These results are compatible with the hypothesis of the lethal phenotype being primarily due to heterophilic interactions between Rst-IrreC extracellular domain and an yet unknown ligand.

  9. Modern optical science

    International Nuclear Information System (INIS)

    2001-05-01

    This book deals with modern optical science, which gives description of properties of light and transmission, ray tracing like Gaussian image, ray tracing and optical system, properties about light wave, a vector properties of light, interference and an interferometer, transform and application of interferometer, diffraction, application on diffraction, solid optical science, measurement of light and laser such as basic principle of laser, kinds of laser, pulse laser, resonator and single mode and multimode.

  10. Experimental demonstrations of all-optical networking functions for WDM optical networks

    Science.gov (United States)

    Gurkan, Deniz

    The deployment of optical networks will enable high capacity links between users but will introduce the problems associated with transporting and managing more channels. Many network functions should be implemented in optical domain; main reasons are: to avoid electronic processing bottlenecks, to achieve data-format and data-rate independence, to provide reliable and cost efficient control and management information, to simultaneously process multiple wavelength channel operation for wavelength division multiplexed (WDM) optical networks. The following novel experimental demonstrations of network functions in the optical domain are presented: Variable-bit-rate recognition of the header information in a data packet. The technique is reconfigurable for different header sequences and uses optical correlators as look-up tables. The header is processed and a signal is sent to the switch for a series of incoming data packets at 155 Mb/s, 622 Mb/s, and 2.5 Gb/s in a reconfigurable network. Simultaneous optical time-slot-interchange and wavelength conversion of the bits in a 2.5-Gb/s data stream to achieve a reconfigurable time/wavelength switch. The technique uses difference-frequency-generation (DFG) for wavelength conversion and fiber Bragg gratings (FBG) as wavelength-dependent optical time buffers. The WDM header recognition module simultaneously recognizing two header bits on each of two 2.5-Gbit/s WDM packet streams. The module is tunable to enable reconfigurable look-up tables. Simultaneous and independent label swapping and wavelength conversion of two WDM channels for a multi-protocol label switching (MPLS) network. Demonstration of label swapping of distinct 8-bit-long labels for two WDM data channels is presented. Two-dimensional code conversion module for an optical code-division multiple-access (O-CDMA) local area network (LAN) system. Simultaneous wavelength conversion and time shifting is achieved to enable flexible code conversion and increase code re

  11. All-optical, thermo-optical path length modulation based on the vanadium-doped fibers.

    Science.gov (United States)

    Matjasec, Ziga; Campelj, Stanislav; Donlagic, Denis

    2013-05-20

    This paper presents an all-fiber, fully-optically controlled, optical-path length modulator based on highly absorbing optical fiber. The modulator utilizes a high-power 980 nm pump diode and a short section of vanadium-co-doped single mode fiber that is heated through absorption and a non-radiative relaxation process. The achievable path length modulation range primarily depends on the pump's power and the convective heat-transfer coefficient of the surrounding gas, while the time response primarily depends on the heated fiber's diameter. An absolute optical length change in excess of 500 µm and a time-constant as short as 11 ms, were demonstrated experimentally. The all-fiber design allows for an electrically-passive and remote operation of the modulator. The presented modulator could find use within various fiber-optics systems that require optical (remote) path length control or modulation.

  12. Advanced digital optical communications

    CERN Document Server

    Binh, Le Nguyen

    2015-01-01

    This book provides a fundamental understanding of digital communication applications in optical communication technologies. Emphasizing operation principles versus mathematical analysis, the Second Edition includes new coverage of superchannel optical transmission systems, metropolitan and long-haul optical systems and networks, and Nyquist pulse shaping and high spectral efficiency of optical transmission systems, as well as new homework problems and examples. Featuring theoretical foundations as well as practical case studies, the text focuses on enhancements to digital technologies that are

  13. Complete achromatic and robustness electro-optic switch between two integrated optical waveguides

    Science.gov (United States)

    Huang, Wei; Kyoseva, Elica

    2018-01-01

    In this paper, we present a novel design of electro-optic modulator and optical switching device, based on current integrated optics technique. The advantages of our optical switching device are broadband of input light wavelength, robustness against varying device length and operation voltages, with reference to previous design. Conforming to our results of previous paper [Huang et al, phys. lett. a, 90, 053837], the coupling of the waveguides has a hyperbolic-secant shape. while detuning has a sign flip at maximum coupling, we called it as with a sign flip of phase mismatch model. The a sign flip of phase mismatch model can produce complete robust population transfer. In this paper, we enhance this device to switch light intensity controllable, by tuning external electric field based on electro-optic effect.

  14. Fiber-optic polarization diversity detection for rotary probe optical coherence tomography.

    Science.gov (United States)

    Lee, Anthony M D; Pahlevaninezhad, Hamid; Yang, Victor X D; Lam, Stephen; MacAulay, Calum; Lane, Pierre

    2014-06-15

    We report a polarization diversity detection scheme for optical coherence tomography with a new, custom, miniaturized fiber coupler with single mode (SM) fiber inputs and polarization maintaining (PM) fiber outputs. The SM fiber inputs obviate matching the optical lengths of the X and Y OCT polarization channels prior to interference and the PM fiber outputs ensure defined X and Y axes after interference. Advantages for this scheme include easier alignment, lower cost, and easier miniaturization compared to designs with free-space bulk optical components. We demonstrate the utility of the detection system to mitigate the effects of rapidly changing polarization states when imaging with rotating fiber optic probes in Intralipid suspension and during in vivo imaging of human airways.

  15. Binary optics: Trends and limitations

    Science.gov (United States)

    Farn, Michael W.; Veldkamp, Wilfrid B.

    1993-01-01

    We describe the current state of binary optics, addressing both the technology and the industry (i.e., marketplace). With respect to the technology, the two dominant aspects are optical design methods and fabrication capabilities, with the optical design problem being limited by human innovation in the search for new applications and the fabrication issue being limited by the availability of resources required to improve fabrication capabilities. With respect to the industry, the current marketplace does not favor binary optics as a separate product line and so we expect that companies whose primary purpose is the production of binary optics will not represent the bulk of binary optics production. Rather, binary optics' more natural role is as an enabling technology - a technology which will directly result in a competitive advantage in a company's other business areas - and so we expect that the majority of binary optics will be produced for internal use.

  16. Diophantine Optics

    Science.gov (United States)

    Rouan, D.

    2016-09-01

    What I call Diophantine optics is the exploitation in optics of some remarkable algebraic relations between powers of integers. The name comes from Diophantus of Alexandria, a greek mathematician, known as the father of algebra. He studied polynomial equations with integer coefficients and integer solutions, called diophantine equations. Since constructive or destructive interferences are playing with optical path differences which are multiple integer (odd or even) of λ/2 and that the complex amplitude is a highly non-linear function of the optical path difference (or equivalently of the phase), one can understand that any Taylor development of this amplitude implies powers of integers. This is the link with Diophantine equations. We show how, especially in the field of interferometry, remarkable relations between powers of integers can help to solve several problems, such as achromatization of a phase shifter or deep nulling efficiency. It appears that all the research that was conducted in this frame of thinking, relates to the field of detection of exoplanets, a very active domain of astrophysics today.

  17. Radiation effects in optical components

    International Nuclear Information System (INIS)

    Friebele, E.J.

    1987-01-01

    This report discusses components of high performance optical devices may be exposed to high energy radiation environments during their lifetime. The effect of these adverse environments depends upon a large number of parameters associated with the radiation (nature, energy, dose, dose rate, etc.) or the system (temperature, optical performance requirements, optical wavelength, optical power, path length, etc.), as well as the intrinsic susceptibility of the optical component itself to degradation

  18. Research in the Optical Sciences

    Science.gov (United States)

    2011-03-21

    Nonimaging Optics , (Elsevier Academic Press, Burlingham, 2005) Chapter 2. S. I. Voropayev and Y. D. Afanasyev. Vortex Structures in a Stratified Fluid...REPORT Research in the Optical Sciences 14. ABSTRACT 16. SECURITY CLASSIFICATION OF: This report decribes the research and results of the activity on...various projects over the period of the grant. The optics of study include atom optics and matter-wave quantum point contacts, theory of optical

  19. Optical computer switching network

    Science.gov (United States)

    Clymer, B.; Collins, S. A., Jr.

    1985-01-01

    The design for an optical switching system for minicomputers that uses an optical spatial light modulator such as a Hughes liquid crystal light valve is presented. The switching system is designed to connect 80 minicomputers coupled to the switching system by optical fibers. The system has two major parts: the connection system that connects the data lines by which the computers communicate via a two-dimensional optical matrix array and the control system that controls which computers are connected. The basic system, the matrix-based connecting system, and some of the optical components to be used are described. Finally, the details of the control system are given and illustrated with a discussion of timing.

  20. Optical analogy. Synthesis report

    International Nuclear Information System (INIS)

    1965-01-01

    The authors report the study of conditions under which light attenuation (reflection, diffusion, absorption) and the attenuation of some radiations (notably thermal neutrons) can be described with analogical calculations. The analogy between light physical properties and neutron properties is not searched for, but the analogy between their attenuation characteristics. After having discussed this possible analogy, they propose a mathematical formulation of neutron and optical phenomena which could theoretically justify the optical analogy. The second part reports a more practical study of optics problems such as the study of simple optics materials and illumination measurements, or more precisely the study of angular distributions of optical reflections, a determination of such angular distributions, and an experimental determination of the albedo

  1. Indoor optical wireless communication system using beam-steering by cascaded diffractive optical elements

    NARCIS (Netherlands)

    Oh, C.W.; Tangdiongga, E.; Koonen, A.M.J.; García-Blanco, S.M.; Boller, Kl.J.; Sefunc, M.A.; Geuzebroek, D.

    2014-01-01

    While the radio spectrum continues to struggle with a soaring bandwidth demand, the optical spectrum promises virtually unlimited license-free bandwidth. We report the feasibility of high-capacity point-to-point links for indoor optical wireless communication with cascaded diffractive optical

  2. [Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT].

    Science.gov (United States)

    Poli, M; Colange, J; Goutagny, B; Sellem, E

    2017-09-01

    Optic nerve head drusen are congenital calcium deposits located in the prelaminar section of the optic nerve head. Their association with visual field defects has been classically described, but the diagnosis of glaucoma is not easy in these cases of altered optic nerve head anatomy. We describe the case of a 67-year-old man with optic nerve head drusen complicated by glaucoma, which was confirmed by visual field and OCT examination of the peripapillary retinal nerve fiber layer (RNFL), but the measurement of the minimum distance between the Bruch membrane opening and the internal limiting membrane (minimum rim width, BMO-MRW) by OCT was normal. OCT of the BMO-MRW is a new diagnostic tool for glaucoma. Superficial optic nerve head drusen, which are found between the internal limiting membrane and the Bruch's membrane opening, overestimate the value of this parameter. BMO-MRW measurement is not adapted to cases of optic nerve head drusen and can cause false-negative results for this parameter, and the diagnosis of glaucoma in this case should be based on other parameters such as the presence of a fascicular defect in the retinal nerve fibers, RNFL or macular ganglion cell complex thinning, as well as visual field data. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Optical properties of graphene superlattices.

    Science.gov (United States)

    Le, H Anh; Ho, S Ta; Nguyen, D Chien; Do, V Nam

    2014-10-08

    In this work, the optical responses of graphene superlattices, i.e. graphene subjected to a periodic scalar potential, are theoretically reported. The optical properties were studied by investigating the optical conductivity, which was calculated using the Kubo formalism. It was found that the optical conductivity becomes dependent on the photon polarization and is suppressed in the photon energy range of (0, Ub), where Ub is the potential barrier height. In the higher photon energy range, i.e. Ω > Ub, the optical conductivity is, however, almost identical to that of pristine graphene. Such behaviors of the optical conductivity are explained microscopically through the analysis of the elements of optical matrices and effectively through a simple model, which is based on the Pauli blocking mechanism.

  4. Optical memory

    Science.gov (United States)

    Mao, Samuel S; Zhang, Yanfeng

    2013-07-02

    Optical memory comprising: a semiconductor wire, a first electrode, a second electrode, a light source, a means for producing a first voltage at the first electrode, a means for producing a second voltage at the second electrode, and a means for determining the presence of an electrical voltage across the first electrode and the second electrode exceeding a predefined voltage. The first voltage, preferably less than 0 volts, different from said second voltage. The semiconductor wire is optically transparent and has a bandgap less than the energy produced by the light source. The light source is optically connected to the semiconductor wire. The first electrode and the second electrode are electrically insulated from each other and said semiconductor wire.

  5. A study of optical design and optimization of laser optics

    Science.gov (United States)

    Tsai, C.-M.; Fang, Yi-Chin

    2013-09-01

    This paper propose a study of optical design of laser beam shaping optics with aspheric surface and application of genetic algorithm (GA) to find the optimal results. Nd: YAG 355 waveband laser flat-top optical system, this study employed the Light tools LDS (least damped square) and the GA of artificial intelligence optimization method to determine the optimal aspheric coefficient and obtain the optimal solution. This study applied the aspheric lens with GA for the flattening of laser beams using collimated laser beam light, aspheric lenses in order to achieve best results.

  6. Jell-O Optics: Edibly Exploring Snell's Law and Optical Power

    Science.gov (United States)

    Hendryx, Jennifer; Reynolds, Mathias

    2012-03-01

    This presentation details a laboratory exercise and/or demonstration of refraction with an inexpensive, simple set-up: a pan of Jell-O, protractors, and laser pointers. This activity is presented from the perspective of an optical sciences graduate student who has spent the school year team-teaching high school math and physics (through Academic Decathlon). The goal is to present some of the fundamentals of optics with an enjoyable and affordable approach. The concepts include Snell's law, index of refraction, and optical power/focal length as they relate to the curvature of a lens.

  7. Optical frequency upconversion technique for transmission of wireless MIMO-type signals over optical fiber.

    Science.gov (United States)

    Shaddad, R Q; Mohammad, A B; Al-Gailani, S A; Al-Hetar, A M

    2014-01-01

    The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF) technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO) signals feeding multiple antennas in the fiber wireless (FiWi) system. A novel optical frequency upconversion (OFU) technique is proposed to solve this problem. In this paper, the novel OFU approach is used to transmit three wireless MIMO signals over a 20 km standard single mode fiber (SMF). The OFU technique exploits one optical source to produce multiple wavelengths by delivering it to a LiNbO3 external optical modulator. The wireless MIMO signals are then modulated by LiNbO3 optical intensity modulators separately using the generated optical carriers from the OFU process. These modulators use the optical single-sideband with carrier (OSSB+C) modulation scheme to optimize the system performance against the fiber dispersion effect. Each wireless MIMO signal is with a 2.4 GHz or 5 GHz carrier frequency, 1 Gb/s data rate, and 16-quadrature amplitude modulation (QAM). The crosstalk between the wireless MIMO signals is highly suppressed, since each wireless MIMO signal is carried on a specific optical wavelength.

  8. Optical Coupling Structures of Fiber-Optic Mach-Zehnder Interferometers Using CO2 Laser Irradiation

    Directory of Open Access Journals (Sweden)

    Chien-Hsing Chen

    2014-01-01

    Full Text Available The Mach-Zehnder interferometer (MZI can be used to test changes in the refractive index of sucrose solutions at different concentrations. However, the popularity of this measurement tool is limited by its substantial size and portability. Therefore, the MZI was integrated with a small fiber-optic waveguide component to develop an interferometer with fiber-optic characteristics, specifically a fiber-optic Mach-Zehnder interferometer (FO-MZI. Optical fiber must be processed to fabricate two optical coupling structures. The two optical coupling structures are a duplicate of the beam splitter, an optical component of the interferometer. Therefore, when the sensor length and the two optical coupling structures vary, the time or path for optical transmission in the sensor changes, thereby influencing the back-end interference signals. The researchers successfully developed an asymmetrical FO-MZI with sensing abilities. The spacing value between the troughs of the sensor length and interference signal exhibited an inverse relationship. In addition, image analysis was employed to examine the size-matching relationship between various sensor lengths and the coupling and decoupling structure. Furthermore, the spectral wavelength shift results measured using a refractive index sensor indicate that FO-MZIs with a sensor length of 38 mm exhibited excellent sensitivity, measuring 59.7 nm/RIU.

  9. EDITORIAL: Optical orientation Optical orientation

    Science.gov (United States)

    SAME ADDRESS *, Yuri; Landwehr, Gottfried

    2008-11-01

    priority of the discovery in the literature, which was partly caused by the existence of the Iron Curtain. I had already enjoyed contact with Boris in the 1980s when the two volumes of Landau Level Spectroscopy were being prepared [2]. He was one of the pioneers of magneto-optics in semiconductors. In the 1950s the band structure of germanium and silicon was investigated by magneto-optical methods, mainly in the United States. No excitonic effects were observed and the band structure parameters were determined without taking account of excitons. However, working with cuprous oxide, which is a direct semiconductor with a relative large energy gap, Zakharchenya and his co-worker Seysan showed that in order to obtain correct band structure parameters, it is necessary to take excitons into account [3]. About 1970 Boris started work on optical orientation. Early work by Hanle in Germany in the 1920s on the depolarization of luminescence in mercury vapour by a transverse magnetic field was not appreciated for a long time. Only in the late 1940s did Kastler and co-workers in Paris begin a systematic study of optical pumping, which led to the award of a Nobel prize. The ideas of optical pumping were first applied by Georges Lampel to solid state physics in 1968. He demonstrated optical orientation of free carriers in silicon. The detection method was nuclear magnetic resonance; optically oriented free electrons dynamically polarized the 29Si nuclei of the host lattice. The first optical detection of spin orientation was demonstrated by with the III-V semiconductor GaSb by Parsons. Due to the various interaction mechanisms of spins with their environment, the effects occurring in semiconductors are naturally more complex than those in atoms. Optical detection is now the preferred method to detect spin alignment in semiconductors. The orientation of spins in crystals pumped with circularly polarized light is deduced from the degree of circular polarization of the recombination

  10. Optical properties of polymer nanocomposites

    Indian Academy of Sciences (India)

    Wintec

    , optical sensors, optical data communication and optical ... our filters (Leon et al 2001), solar cells and optical sen- sors (Tanaka et al 1991; Tokizaki et .... volume fractions (Top panel: tanψ for volume fractions, 1⋅2%. (dash) and 0⋅6% (dot); ...

  11. Optical coatings:trends and challenges

    Institute of Scientific and Technical Information of China (English)

    Norbert Kaiser; Torsten Feigl; Olaf Stenzel; Ulrike Schulz; Ming-hong Yang

    2005-01-01

    New applications in optoelectronics, photonics, telecommunication, displays, optical data processing, biomedicine, sensors, energy control, automobile, aerospace, and architecture stimulation are important developments in physics and technology of optical coatings. This paper will focus on the latest advances in the areas of new optical film systems and devices, new optical coating materials and film fabrication techniques, process control and monitoring, and different advanced applications. Particularly, focus is on optical films that combine optical design with microstructural features tailored on the nanometer and micrometer scales. Evaluation of film stability and integrity in harsh industrial environments and their compatibility with organic polymers are important as well.

  12. Progress in optics

    CERN Document Server

    Wolf, Emil

    2008-01-01

    In the fourty-six years that have gone by since the first volume of Progress in Optics was published, optics has become one of the most dynamic fields of science. The volumes in this series which have appeared up to now contain more than 300 review articles by distinguished research workers, which have become permanent records for many important developments.- Metamaterials- Polarization Techniques- Linear Baisotropic Mediums- Ultrafast Optical Pulses- Quantum Imaging- Point-Spread Funcions- Discrete Wigner Functions

  13. Optical Fibre Bundle

    CERN Multimedia

    These are sample fibre optic cables which are used for networking. Optical fibers are widely used in fiber-optic communications, where they permit transmission over longer distances and at higher bandwidths (data rates) than wire cables. Fibers are used instead of metal wires because signals travel along them with less loss and are also immune to electromagnetic interference. This is useful for somewhere like CERN where magnets with their highly powerful magnetic fields could pose a problem.

  14. Ultra-high accuracy optical testing: creating diffraction-limited short-wavelength optical systems

    International Nuclear Information System (INIS)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman, Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli, Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-01-01

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-(angstrom) and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date

  15. Measuring optical properties of a blood vessel model using optical coherence tomography

    Science.gov (United States)

    Levitz, David; Hinds, Monica T.; Tran, Noi; Vartanian, Keri; Hanson, Stephen R.; Jacques, Steven L.

    2006-02-01

    In this paper we develop the concept of a tissue-engineered optical phantom that uses engineered tissue as a phantom for calibration and optimization of biomedical optics instrumentation. With this method, the effects of biological processes on measured signals can be studied in a well controlled manner. To demonstrate this concept, we attempted to investigate how the cellular remodeling of a collagen matrix affected the optical properties extracted from optical coherence tomography (OCT) images of the samples. Tissue-engineered optical phantoms of the vascular system were created by seeding smooth muscle cells in a collagen matrix. Four different optical properties were evaluated by fitting the OCT signal to 2 different models: the sample reflectivity ρ and attenuation parameter μ were extracted from the single scattering model, and the scattering coefficient μ s and root-mean-square scattering angle θ rms were extracted from the extended Huygens-Fresnel model. We found that while contraction of the smooth muscle cells was clearly evident macroscopically, on the microscopic scale very few cells were actually embedded in the collagen. Consequently, no significant difference between the cellular and acellular samples in either set of measured optical properties was observed. We believe that further optimization of our tissue-engineering methods is needed in order to make the histology and biochemistry of the cellular samples sufficiently different from the acellular samples on the microscopic level. Once these methods are optimized, we can better verify whether the optical properties of the cellular and acellular collagen samples differ.

  16. Non-linear optical materials

    CERN Document Server

    Saravanan, R

    2018-01-01

    Non-linear optical materials have widespread and promising applications, but the efforts to understand the local structure, electron density distribution and bonding is still lacking. The present work explores the structural details, the electron density distribution and the local bond length distribution of some non-linear optical materials. It also gives estimation of the optical band gap, the particle size, crystallite size, and the elemental composition from UV-Visible analysis, SEM, XRD and EDS of some non-linear optical materials respectively.

  17. All-optical clock recovery of NRZ-DPSK signals using optical resonator-type filters

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Seoane, Jorge; Ji, Hua

    2009-01-01

    It is shown how introducing a limited rise time to the driving signal enables all-optical clock recovery of NRZ-DPSK signals generated using a phase modulator. A Fabry-Perot filter is used to generate the optical clock.......It is shown how introducing a limited rise time to the driving signal enables all-optical clock recovery of NRZ-DPSK signals generated using a phase modulator. A Fabry-Perot filter is used to generate the optical clock....

  18. Broadband phase-preserved optical elevator

    OpenAIRE

    Luo, Yuan; Han, Tiancheng; Zhang, Baile; Qiu, Cheng-Wei; Barbastathis, George

    2011-01-01

    Phase-preserved optical elevator is an optical device to lift up an entire plane virtually without distortion in light path or phase. Using transformation optics, we have predicted and observed the realization of such a broadband phase-preserved optical elevator, made of a natural homogeneous birefringent crystal without resorting to absorptive and narrowband metamaterials involving time-consuming nano-fabrication. In our demonstration, the optical elevator is designed to lift a sheet upwards...

  19. Fundamentals of nonlinear optical materials

    Indian Academy of Sciences (India)

    Nonlinear optics; nonlinear polarization; optical fiber communication; optical switch- ing. PACS Nos 42.65Tg; ... The importance of nonlinear optics is to understand the nonlinear behavior in the induced polarization and to ..... but much work in material development and characterization remains to be done. 16. Conclusion.

  20. Advances in integrated optics

    CERN Document Server

    Chester, A; Bertolotti, M

    1994-01-01

    This volwne contains the Proceedings of a two-week summer conference titled "Advances in Integrated Optics" held June 1-9, 1993, in Erice, Sicily. This was the 18th annual course organized by the International School of Quantum Electronics, under the auspices of the "Ettore Majorana" Centre for Scientific Culture. The term Integrated Optics signifies guided-wave optical circuits consisting of two or more devices on a single substrate. Since its inception in the late 1960's, Integrated Optics has evolved from a specialized research topic into a broad field of work, ranging from basic research through commercial applications. Today many devices are available on market while a big effort is devolved to research on integrated nonlinear optical devices. This conference was organized to provide a comprehensive survey of the frontiers of this technology, including fundamental concepts, nonlinear optical materials, devices both in the linear and nonlinear regimes, and selected applications. These Proceedings update a...

  1. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  2. Optical radiation and visual health

    International Nuclear Information System (INIS)

    Waxler, M.; Hitchins, V.M.

    1986-01-01

    This book provides a focus on the parameters of ultraviolet light, visible, and infrared radiation s which could cause long-term visual health problems in humans. It reviews early research on radiation effects on the eye, and gives detailed attention to the hazardous effects of optical radiation on the retinal pigment epithelium and the photoreceptors. These data are further analyzed with regard to five potential long-term visual health problems; retinal degeneration, visual aging, disorder of visual development, ocular drug phototoxicity, and cataracts. Finally, epidemiologic principles for studying the relationships between optical radiation and long-term visual health problems are reviewed, concluding with the implications for future research and radiation protection. The contents include: historical perspectives; optical radiation and cataracts; the involvement of the retinal pigment epithelium (RPE); optical radiation damage to the ocular photoreceptors; possible role of optical radiation in retinal degenerations; optical radiation and the aged eye; optical radiation effects on aging and visual perception; optical radiation effects on visual development; and index

  3. Active material, optical mode and cavity impact on nanoscale electro-optic modulation performance

    Science.gov (United States)

    Amin, Rubab; Suer, Can; Ma, Zhizhen; Sarpkaya, Ibrahim; Khurgin, Jacob B.; Agarwal, Ritesh; Sorger, Volker J.

    2017-10-01

    Electro-optic modulation is a key function in optical data communication and possible future optical compute engines. The performance of modulators intricately depends on the interaction between the actively modulated material and the propagating waveguide mode. While a variety of high-performance modulators have been demonstrated, no comprehensive picture of what factors are most responsible for high performance has emerged so far. Here we report the first systematic and comprehensive analytical and computational investigation for high-performance compact on-chip electro-optic modulators by considering emerging active materials, model considerations and cavity feedback at the nanoscale. We discover that the delicate interplay between the material characteristics and the optical mode properties plays a key role in defining the modulator performance. Based on physical tradeoffs between index modulation, loss, optical confinement factors and slow-light effects, we find that there exist combinations of bias, material and optical mode that yield efficient phase or amplitude modulation with acceptable insertion loss. Furthermore, we show how material properties in the epsilon near zero regime enable reduction of length by as much as by 15 times. Lastly, we introduce and apply a cavity-based electro-optic modulator figure of merit, Δλ/Δα, relating obtainable resonance tuning via phase shifting relative to the incurred losses due to the fundamental Kramers-Kronig relations suggesting optimized device operating regions with optimized modulation-to-loss tradeoffs. This work paves the way for a holistic design rule of electro-optic modulators for high-density on-chip integration.

  4. Optical properties of graphene superlattices

    International Nuclear Information System (INIS)

    Le, H Anh; Do, V Nam; Ho, S Ta; Nguyen, D Chien

    2014-01-01

    In this work, the optical responses of graphene superlattices, i.e. graphene subjected to a periodic scalar potential, are theoretically reported. The optical properties were studied by investigating the optical conductivity, which was calculated using the Kubo formalism. It was found that the optical conductivity becomes dependent on the photon polarization and is suppressed in the photon energy range of (0, U b ), where U b is the potential barrier height. In the higher photon energy range, i.e. Ω > U b , the optical conductivity is, however, almost identical to that of pristine graphene. Such behaviors of the optical conductivity are explained microscopically through the analysis of the elements of optical matrices and effectively through a simple model, which is based on the Pauli blocking mechanism. (paper)

  5. Pappus in optical space

    NARCIS (Netherlands)

    Koenderink, J.J.; Doorn, A.J. van; Kappers, A.M.L.; Todd, J.T.

    2002-01-01

    Optical space differs from physical space. The structure of optical space has generallybeen assumed to be metrical. In contradistinction,we do not assume anymetric, but only incidence relations (i.e., we assume that optical points and lines exist and that two points define a unique line, and two

  6. Optical Network Virtualisation Using Multitechnology Monitoring and SDN-Enabled Optical Transceiver

    Science.gov (United States)

    Ou, Yanni; Davis, Matthew; Aguado, Alejandro; Meng, Fanchao; Nejabati, Reza; Simeonidou, Dimitra

    2018-05-01

    We introduce the real-time multi-technology transport layer monitoring to facilitate the coordinated virtualisation of optical and Ethernet networks supported by optical virtualise-able transceivers (V-BVT). A monitoring and network resource configuration scheme is proposed to include the hardware monitoring in both Ethernet and Optical layers. The scheme depicts the data and control interactions among multiple network layers under the software defined network (SDN) background, as well as the application that analyses the monitored data obtained from the database. We also present a re-configuration algorithm to adaptively modify the composition of virtual optical networks based on two criteria. The proposed monitoring scheme is experimentally demonstrated with OpenFlow (OF) extensions for a holistic (re-)configuration across both layers in Ethernet switches and V-BVTs.

  7. Ultrafast optics. Ultrafast optical control by few photons in engineered fiber.

    Science.gov (United States)

    Nissim, R; Pejkic, A; Myslivets, E; Kuo, B P; Alic, N; Radic, S

    2014-07-25

    Fast control of a strong optical beam by a few photons is an outstanding challenge that limits the performance of quantum sensors and optical processing devices. We report that a fast and efficient optical gate can be realized in an optical fiber that has been engineered with molecular-scale accuracy. Highly efficient, distributed phase-matched photon-photon interaction was achieved in the fiber with locally controlled, nanometer-scale core variations. A three-photon input was used to manipulate a Watt-scale beam at a speed exceeding 500 gigahertz. In addition to very fast beam control, the results provide a path to developing a new class of sensitive receivers capable of operating at very high rates. Copyright © 2014, American Association for the Advancement of Science.

  8. The Optical Society's 2016 topical meeting on optical interference coatings: introduction.

    Science.gov (United States)

    Ristau, Detlev; Li, Li; Sargent, Robert; Sytchkova, Anna

    2017-02-01

    This feature issue of Applied Optics is dedicated to the 13th Topical Meeting on Optical Interference Coatings, which was held June 19-24, 2016, in Tucson, Arizona, USA. The conference, taking place every three years, is a focal point for global technical interchange in the field of optical interference coatings and provides premier opportunities for people working in the field to present their new advances in research and development. Papers presented at the meeting covered a broad range of topics, including fundamental research on coating design theory, new materials, and deposition and characterization technologies, as well as the vast and growing number of applications in electronic displays, communication, optical instruments, high power and ultra-fast lasers, solar cells, space missions, gravitational wave detection, and many others.

  9. Coupled-resonator optical waveguides

    DEFF Research Database (Denmark)

    Raza, Søren; Grgic, Jure; Pedersen, Jesper Goor

    2010-01-01

    Coupled-resonator optical waveguides hold potential for slow-light propagation of optical pulses. The dispersion properties may adequately be analyzed within the framework of coupled-mode theory. We extend the standard coupled-mode theory for such structures to also include complex-valued paramet......Coupled-resonator optical waveguides hold potential for slow-light propagation of optical pulses. The dispersion properties may adequately be analyzed within the framework of coupled-mode theory. We extend the standard coupled-mode theory for such structures to also include complex...

  10. Optical engineering of diamond

    CERN Document Server

    Rabeau, James R

    2013-01-01

    This is the first comprehensive book on the engineering of diamond optical devices. It will give readers an up-to-date account of the properties of optical quality synthetic diamond (single crystal, nanodiamond and polycrystalline) and reviews the large and growing field of engineering of diamond-based optical devices, with applications in quantum computation, nano-imaging, high performance lasers, and biomedicine. It aims to provide scientists, engineers and physicists with a valuable resource and reference book for the design and performance of diamond-based optical devices.

  11. Optical signal processing techniques and applications of optical phase modulation in high-speed communication systems

    Science.gov (United States)

    Deng, Ning

    In recent years, optical phase modulation has attracted much research attention in the field of fiber optic communications. Compared with the traditional optical intensity-modulated signal, one of the main merits of the optical phase-modulated signal is the better transmission performance. For optical phase modulation, in spite of the comprehensive study of its transmission performance, only a little research has been carried out in terms of its functions, applications and signal processing for future optical networks. These issues are systematically investigated in this thesis. The research findings suggest that optical phase modulation and its signal processing can greatly facilitate flexible network functions and high bandwidth which can be enjoyed by end users. In the thesis, the most important physical-layer technology, signal processing and multiplexing, are investigated with optical phase-modulated signals. Novel and advantageous signal processing and multiplexing approaches are proposed and studied. Experimental investigations are also reported and discussed in the thesis. Optical time-division multiplexing and demultiplexing. With the ever-increasing demand on communication bandwidth, optical time division multiplexing (OTDM) is an effective approach to upgrade the capacity of each wavelength channel in current optical systems. OTDM multiplexing can be simply realized, however, the demultiplexing requires relatively complicated signal processing and stringent timing control, and thus hinders its practicability. To tackle this problem, in this thesis a new OTDM scheme with hybrid DPSK and OOK signals is proposed. Experimental investigation shows this scheme can greatly enhance the demultiplexing timing misalignment and improve the demultiplexing performance, and thus make OTDM more practical and cost effective. All-optical signal processing. In current and future optical communication systems and networks, the data rate per wavelength has been approaching

  12. Harnessing mode-selective nonlinear optics for on-chip multi-channel all-optical signal processing

    Directory of Open Access Journals (Sweden)

    Ming Ma

    2016-11-01

    Full Text Available All-optical signal processing based on nonlinear optical effects allows for the realization of important functions in telecommunications including wavelength conversion, optical multiplexing/demultiplexing, Fourier transformation, and regeneration, amongst others, on ultrafast time scales to support high data rate transmission. In integrated photonic subsystems, the majority of all-optical signal processing systems demonstrated to date typically process only a single channel at a time or perform a single processing function, which imposes a serious limitation on the functionality of integrated solutions. Here, we demonstrate how nonlinear optical effects can be harnessed in a mode-selective manner to perform simultaneous multi-channel (two and multi-functional optical signal processing (i.e., regenerative wavelength conversion in an integrated silicon photonic device. This approach, which can be scaled to a higher number of channels, opens up a new degree of freedom for performing a broad range of multi-channel nonlinear optical signal processing functions using a single integrated photonic device.

  13. Optical fiber spectrophotometer

    International Nuclear Information System (INIS)

    Zhuang Weixin; Tian Guocheng; Ye Guoan; Zhou Zhihong; Cheng Weiwei; Huang Lifeng; Liu Suying; Tang Yanji; Hu Jingxin; Zhao Yonggang

    1998-12-01

    A method called 'Two Arm's Photo out and Electricity Send-back' is introduced. UV-365 UV/VIS/NIR spectrophotometer has been reequipped by this way with 5 meters long optical fiber. Another method called 'One Arm's Photo out and Photo Send-back' is also introduced. λ 19 UV/VIS/NIR spectrophotometer has been reequipped by this way with 10 meters long optical fiber. Optical fiber spectrophotometer can work as its main set. So it is particularly applicable to radio activity work

  14. Optical Computing Research.

    Science.gov (United States)

    1987-10-30

    1489-1496, 1985. 13. W.T. Welford and R. Winston, The Optics of Nonimaging Concentrators, Academic Press, New York, N.Y., 1978 (see Appendix A). 14. R.H...AD-fIB? Ŗ OPTICAL CONPIITINO RESEAIRCII(U STANFORD UlNIV CA STINFORD / ELECTRONICS LASS J N 0000W4 30 OCT 97 SMAFOSR-TR-S?-1635 RFOSR-96...Force Base ELEMENT NO. NO. NO. NO. Washington, DC 20332-6448 11. TITLE ,Include Security ClaaticaonUNCLASSIFIED 61102F 2305 B4 OPTICAL COMPUTING RESEARCH

  15. Recent advancements in robotic micro-optical assembly at the Lockheed Martin Optical Payload Center of Excellence

    Science.gov (United States)

    Hwang, David; Larson, Thomas M.

    2017-08-01

    Lockheed Martin Space Systems Company Optical Payloads Center of Excellence is in process of standing up the Robotic Optical Assembly System (ROAS) capability at Lockheed Martin Coherent Technologies in Colorado. This currently implemented Robotic Optical Assembly has enabled Lockheed Martin to create world-leading, ultra-lowSWAP photonic devices using a closed-loop control robot to precisely position and align micro-optics with a potential fill factor of >25 optics per square inch. This paper will discuss the anticipated applications and optical capability when ROAS is fully operational, as well as challenge the audience to update their "rules of thumb" and best practices when designing low-SWAP optical-mechanical systems that take advantage of Lockheed Martin's ROAS capability. This paper will reveal demonstrated optical pointing and stability performance achievable with ROAS and why we believe these optical specifications are relevant for the majority of anticipated applications. After a high level overview of the ROAS current state, this paper will focus in on recent results of the "Reworkable Micro-Optics Mounting IRAD". Results from this IRAD will correlate to the anticipated optical specifications required for relevant applications.

  16. Loss of binocular vision as direct cause for misrouting of temporal retinal fibers in albinism.

    Science.gov (United States)

    Banihani, Saleh M

    2015-10-01

    In humans, the nasal retina projects to the contralateral hemisphere, whereas the temporal retina projects ipsilaterally. The nasotemporal line that divides the retina into crossed and uncrossed parts coincides with the vertical meridian through the fovea. This normal projection of the retina is severely altered in albinism, in which the nasotemporal line shifted into the temporal retina with temporal retinal fibers cross the midline at the optic chiasm. This study proposes the loss of binocular vision as direct cause for misrouting of temporal retinal fibers and shifting of the nasotemporal line temporally in albinism. It is supported by many observations that clearly indicate that loss of binocular vision causes uncrossed retinal fibers to cross the midline. This hypothesis may alert scientists and clinicians to find ways to prevent or minimize the loss of binocular vision that may occur in some diseases such as albinism and early squint. Hopefully, this will minimize the misrouting of temporal fibers and improve vision in such diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Endoscopic Endonasal Approach for Resection of a Pediatric Craniopharyngioma: Operative Video and Technical Nuances.

    Science.gov (United States)

    Liu, James K; Eloy, Jean Anderson

    2018-04-01

    We present a pediatric case of a retrochiasmatic craniopharyngioma in the suprasellar region with third ventricular extension that was resected through a purely endoscopic endonasal approach (EEA) via the transplanum transtuberculum corridor. The patient is a 12-year-old boy who presented with progressive visual loss and panhypopituitarism. The EEA allows direct visualization of the undersurface of the optic chiasm and hypothalamus so that safe and meticulous tumor dissection can be performed to preserve these critical neurovascular structures. This video atlas demonstrates the operative technique and surgical nuances of the endoscopic skull base approach, microdissection of the tumor from the critical neurovascular structures, and multilayered reconstruction of the skull base defect with a nasoseptal flap. A gross total resection was achieved, and the patient was neurologically intact with improved visual acuity and visual fields. In summary, the EEA via the transplanum transtuberculum corridor is an important strategy in the armamentarium for surgical management of pediatric craniopharyngiomas. The link to the video can be found at: https://youtu.be/bmgO_PMRHPk .

  18. Fault location in optical networks

    Science.gov (United States)

    Stevens, Rick C [Apple Valley, MN; Kryzak, Charles J [Mendota Heights, MN; Keeler, Gordon A [Albuquerque, NM; Serkland, Darwin K [Albuquerque, NM; Geib, Kent M [Tijeras, NM; Kornrumpf, William P [Schenectady, NY

    2008-07-01

    One apparatus embodiment includes an optical emitter and a photodetector. At least a portion of the optical emitter extends a radial distance from a center point. The photodetector provided around at least a portion of the optical emitter and positioned outside the radial distance of the portion of the optical emitter.

  19. Novel concepts in near-field optics: from magnetic near-field to optical forces

    Science.gov (United States)

    Yang, Honghua

    Driven by the progress in nanotechnology, imaging and spectroscopy tools with nanometer spatial resolution are needed for in situ material characterizations. Near-field optics provides a unique way to selectively excite and detect elementary electronic and vibrational interactions at the nanometer scale, through interactions of light with matter in the near-field region. This dissertation discusses the development and applications of near-field optical imaging techniques, including plasmonic material characterization, optical spectral nano-imaging and magnetic field detection using scattering-type scanning near-field optical microscopy (s-SNOM), and exploring new modalities of optical spectroscopy based on optical gradient force detection. Firstly, the optical dielectric functions of one of the most common plasmonic materials---silver is measured with ellipsometry, and analyzed with the Drude model over a broad spectral range from visible to mid-infrared. This work was motivated by the conflicting results of previous measurements, and the need for accurate values for a wide range of applications of silver in plasmonics, optical antennas, and metamaterials. This measurement provides a reference for dielectric functions of silver used in metamaterials, plasmonics, and nanophotonics. Secondly, I implemented an infrared s-SNOM instrument for spectroscopic nano-imaging at both room temperature and low temperature. As one of the first cryogenic s-SNOM instruments, the novel design concept and key specifications are discussed. Initial low-temperature and high-temperature performances of the instrument are examined by imaging of optical conductivity of vanadium oxides (VO2 and V2O 3) across their phase transitions. The spectroscopic imaging capability is demonstrated on chemical vibrational resonances of Poly(methyl methacrylate) (PMMA) and other samples. The third part of this dissertation explores imaging of optical magnetic fields. As a proof-of-principle, the magnetic

  20. Design issues of optical router for metropolitan optical network (MON) applications

    Science.gov (United States)

    Wei, Wei; Zeng, QingJi

    2001-10-01

    The popularity of the Internet has caused the traffic on the Metro Area Network (MAN) to grow drastically every year. It is believed that Wavelength Division Multiplexing (WDM) has become a cornerstone technology in the MAN. Solutions to provide a MAN with high bandwidth, good scalability and easy management are being constantly searched from both IP and WDM. In this paper we firstly propose a metro optical network architecture based on GMPLS--a flexible, highly scalable IP over WDM optical network architecture for the delivery of public network IP services. Two kinds of node including Electronic Label Switching Router (E-LSR) and Optical Router (O-LSR) are involved in this metro optical network architecture. Secondly, we mainly focus on design issues of OR including multi-granularity electro-optical hybrid switching fabrics, intelligent OTU, contro l plane software and etc. And we also discuss some issues such as routing, forwarding and management of OR. Finally, we reach conclusions that OR based on GMPLS and hybrid-switching fabrics is suitable for current multi-services application environment of MON and optimistic for IP traffic transfer.

  1. BeamOptics. A program for analytical beam optics

    International Nuclear Information System (INIS)

    Autin, B.; Carli, C.; D'Amico, T.; Groebner, O.; Martini, M.; Wildner, E.

    1998-01-01

    Analytical beam optics deals with the basic properties of the magnetic modules which compose particle accelerators in the same way as light optics was developed for telescopes, microscopes, or other instruments. The difference between photon and charged-particle optics lies in the nature of the field which acts upon the particle. The magnets of accelerators do not have the rotational symmetry of glass lenses and the computational problems are much more difficult. For this reason, the symbolic program BeamOptics has been written to assist the user in finding the parameters of systems whose complexity is better treated by computer than by hand. Symbolic results may be hard to interpret. Thin-lens models have been adopted because their description is algebraic and emphasis has been put on the existence of solutions, the number of solutions, and simple yet unknown special schemes. The program can also be applied to real machines with long elements. In that case, it works with numerical data but the results are accessible through continuous functions which provide the machine parameters at arbitrary positions along the reference orbit. The code is organized to be implemented in accelerator controls and has functions to correct all the first-order perturbations using a universal procedure. (orig.)

  2. Pappus in optical space

    NARCIS (Netherlands)

    Koenderink, Jan J.; van Doorn, Andrea J.; Kappers, Astrid M L; Todd, James T.

    Optical space differs from physical space. The structure of optical space has generally been assumed to be metrical. In contradistinction, we do not assume any metric, but only incidence relations (i.e., we assume that optical points and lines exist and that two points define a unique line, and two

  3. Fun with Optical Fibres

    Science.gov (United States)

    Alti, Kamlesh

    2017-01-01

    Optical fibres play a very crucial role in today's technologies. Academic courses in optical fibres start at the undergraduate level. Nevertheless, student's curiosity towards optical fibres starts from the school level. In this paper, some fun experiments have been designed for both school and college students, which have some concrete…

  4. Cadmium affects retinogenesis during zebrafish embryonic development

    International Nuclear Information System (INIS)

    Hen Chow, Elly Suk; Yu Hui, Michelle Nga; Cheng, Chi Wa; Cheng, Shuk Han

    2009-01-01

    Ocular malformations are commonly observed in embryos of aquatic species after exposure to toxicants. Using zebrafish embryos as the model organism, we showed that cadmium exposure from sphere stage (4 hpf) to end of segmentation stage (24 hpf) induced microphthalmia in cadmium-treated embryos. Embryos with eye defects were then assessed for visual abilities. Cadmium-exposed embryos were behaviorally blind, showing hyperpigmentation and loss of camouflage response to light. We investigated the cellular basis of the formation of the small eyes phenotype and the induction of blindness by studying retina development and retinotectal projections. Retinal progenitors were found in cadmium-treated embryos albeit in smaller numbers. The number of retinal ganglion cells (RGC), the first class of retinal cells to differentiate during retinogenesis, was reduced, while photoreceptor cells, the last batch of retinal neurons to differentiate, were absent. Cadmium also affected the propagation of neurons in neurogenic waves. The neurons remained in the ventronasal area and failed to spread across the retina. Drastically reduced RGC axons and disrupted optic stalk showed that the optic nerves did not extend from the retina beyond the chiasm into the tectum. Our data suggested that impairment in neuronal differentiation of the retina, disruption in RGC axon formation and absence of cone photoreceptors were the causes of microphthalmia and visual impairment in cadmium-treated embryos

  5. Progress In Optical Memory Technology

    Science.gov (United States)

    Tsunoda, Yoshito

    1987-01-01

    More than 20 years have passed since the concept of optical memory was first proposed in 1966. Since then considerable progress has been made in this area together with the creation of completely new markets of optical memory in consumer and computer application areas. The first generation of optical memory was mainly developed with holographic recording technology in late 1960s and early 1970s. Considerable number of developments have been done in both analog and digital memory applications. Unfortunately, these technologies did not meet a chance to be a commercial product. The second generation of optical memory started at the beginning of 1970s with bit by bit recording technology. Read-only type optical memories such as video disks and compact audio disks have extensively investigated. Since laser diodes were first applied to optical video disk read out in 1976, there have been extensive developments of laser diode pick-ups for optical disk memory systems. The third generation of optical memory started in 1978 with bit by bit read/write technology using laser diodes. Developments of recording materials including both write-once and erasable have been actively pursued at several research institutes. These technologies are mainly focused on the optical memory systems for computer application. Such practical applications of optical memory technology has resulted in the creation of such new products as compact audio disks and computer file memories.

  6. Diffusion tensor imaging of occult injury of optic radiation following optic neuritis in multiple sclerosis.

    Science.gov (United States)

    Chen, Jiafeng; Zhu, Lijun; Li, He; Lu, Ziwen; Chen, Xin; Fang, Shaokuan

    2016-10-01

    Multiple sclerosis (MS) is easily detected by routine magnetic resonance imaging (MRI). However, it is not possible to detect early or occult lesions in MS by routine MRI, and this may explain the inconsistency between the severity of the lesions found by MRI and the degree of clinical disability of patients with MS. The present study included 10 patients with relapsing-remitting MS and 10 healthy volunteers. Each patient underwent routine 3.0 T MRI, diffusion tensor imaging (DTI), and diffusion tensor tractography (DTT). Optic nerve and optic radiation were analyzed by DTI and DTT. The fractional anisotropy (FA), mean diffusivity (MD), λ // , and λ ┴ values were measured. In the 10 patients with MS, 7 optic nerves were affected, and 13 optic nerves were not affected. Cranial MRI showed that optic nerve thickening and hyperintensity occurred in 2 patients with MS. In the directionally encoded color maps, a hypointensive green signal in the optic nerve was observed in 3 patients with MS. The FA values were significantly lower and the MD, λ // , and λ ┴ values were significantly higher in the affected and unaffected optic nerves and optic radiations in patients with MS in comparison with controls (P0.05). Diffusion tensor imaging is sensitive in the detection of occult injury of the optic nerve and optic radiation following optic neuritis. Diffusion tensor imaging may be a useful tool for the early diagnosis, treatment and management of MS.

  7. Optical Angular Momentum

    International Nuclear Information System (INIS)

    Arimondo, Ennio

    2004-01-01

    For many years the Institute of Physics has published books on hot topics based on a collection of reprints from different journals, including some remarks by the editors of each volume. The book on Optical Angular Momentum, edited by L Allen, S M Barnett and M J Padgett, is a recent addition to the series. It reproduces forty four papers originally published in different journals and in a few cases it provides direct access to works not easily accessible to a web navigator. The collection covers nearly a hundred years of progress in physics, starting from an historic 1909 paper by Poynting, and ending with a 2002 paper by Padgett, Barnett and coworkers on the measurement of the orbital angular momentum of a single photon. The field of optical angular momentum has expanded greatly, creating an interdisciplinary attraction for researchers operating in quantum optics, atomic physics, solid state physics, biophysics and quantum information theory. The development of laser optics, especially the control of single mode sources, has made possible the specific design of optical radiation modes with a high degree of control on the light angular momentum. The editors of this book are important figures in the field of angular momentum, having contributed to key progress in the area. L Allen published an historical paper in 1999, he and M J Padgett (together with M Babiker) produced few years ago a long review article which is today still the most complete basic introduction to the angular momentum of light, while S M Barnett has contributed several high quality papers to the progress of this area of physics. The editors' choice provides an excellent overview to all readers, with papers classified into eight different topics, covering the basic principles of the light and spin and orbital angular momentum, the laboratory tools for creating laser beams carrying orbital angular momentum, the optical forces and torques created by laser beams carrying angular momentum on

  8. Optics. Observation of optical polarization Möbius strips.

    Science.gov (United States)

    Bauer, Thomas; Banzer, Peter; Karimi, Ebrahim; Orlov, Sergej; Rubano, Andrea; Marrucci, Lorenzo; Santamato, Enrico; Boyd, Robert W; Leuchs, Gerd

    2015-02-27

    Möbius strips are three-dimensional geometrical structures, fascinating for their peculiar property of being surfaces with only one "side"—or, more technically, being "nonorientable" surfaces. Despite being easily realized artificially, the spontaneous emergence of these structures in nature is exceedingly rare. Here, we generate Möbius strips of optical polarization by tightly focusing the light beam emerging from a q-plate, a liquid crystal device that modifies the polarization of light in a space-variant manner. Using a recently developed method for the three-dimensional nanotomography of optical vector fields, we fully reconstruct the light polarization structure in the focal region, confirming the appearance of Möbius polarization structures. The preparation of such structured light modes may be important for complex light beam engineering and optical micro- and nanofabrication. Copyright © 2015, American Association for the Advancement of Science.

  9. Adapting an optical nanoantenna for high E-field probing applications to a waveguided optical waveguide (WOW)

    DEFF Research Database (Denmark)

    Rindorf, Lars Henning; Glückstad, Jesper

    2013-01-01

    In the current work we intend to use the optical nano-antenna to include various functionalities for the recently demonstrated waveguided optical waveguide (WOW) by Palima et al. (Optics Express 2012). Specifically, we intend to study a WOW with an optical nano-antenna which can block the guiding......-stop characteristic. We give geometrical parameters necessary for realizing functioning nanoantennas. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.......In the current work we intend to use the optical nano-antenna to include various functionalities for the recently demonstrated waveguided optical waveguide (WOW) by Palima et al. (Optics Express 2012). Specifically, we intend to study a WOW with an optical nano-antenna which can block the guiding...... light wavelength while admitting other wavelengths of light which address certain functionalities, e.g. drug release, in the WOW. In particular, we study a bow-tie optical nano-antenna to circular dielectric waveguides in aqueous environments. It is shown with finite element computer simulations...

  10. SCALE FACTOR DETERMINATION METHOD OF ELECTRO-OPTICAL MODULATOR IN FIBER-OPTIC GYROSCOPE

    Directory of Open Access Journals (Sweden)

    A. S. Aleynik

    2016-05-01

    Full Text Available Subject of Research. We propose a method for dynamic measurement of half-wave voltage of electro-optic modulator as part of a fiber optic gyroscope. Excluding the impact of the angular acceleration o​n measurement of the electro-optical coefficient is achieved through the use of homodyne demodulation method that allows a division of the Sagnac phase shift signal and an auxiliary signal for measuring the electro-optical coefficient in the frequency domain. Method. The method essence reduces to decomposition of step of digital serrodyne modulation in two parts with equal duration. The first part is used for quadrature modulation signals. The second part comprises samples of the auxiliary signal used to determine the value of the scale factor of the modulator. Modeling is done in standalone model, and as part of a general model of the gyroscope. The applicability of the proposed method is investigated as well as its qualitative and quantitative characteristics: absolute and relative accuracy of the electro-optic coefficient, the stability of the method to the effects of angular velocities and accelerations, method resistance to noise in actual devices. Main Results. The simulation has showed the ability to measure angular velocity changing under the influence of angular acceleration, acting on the device, and simultaneous measurement of electro-optical coefficient of the phase modulator without interference between these processes. Practical Relevance. Featured in the paper the ability to eliminate the influence of the angular acceleration on the measurement accuracy of the electro-optical coefficient of the phase modulator will allow implementing accurate measurement algorithms for fiber optic gyroscopes resistant to a significant acceleration in real devices.

  11. Optical microscope illumination analysis using through-focus scanning optical microscopy.

    Science.gov (United States)

    Attota, Ravi Kiran; Park, Haesung

    2017-06-15

    Misalignment of the aperture diaphragm present in optical microscopes results in angular illumination asymmetry (ANILAS) at the sample plane. Here we show that through-focus propagation of ANILAS results in a lateral image shift with a focus position. This could lead to substantial errors in quantitative results for optical methods that use through-focus images such as three-dimensional nanoparticle tracking, confocal microscopy, and through-focus scanning optical microscopy (TSOM). A correlation exists between ANILAS and the slant in TSOM images. Hence, the slant in the TSOM image can be used to detect, analyze, and rectify the presence of ANILAS.

  12. Optics, light and lasers

    CERN Document Server

    Meschede, Dieter

    2008-01-01

    Starting from the concepts of classical optics, Optics, Light and Lasers introduces in detail the phenomena of linear and nonlinear light matter interaction, the properties of modern laser sources, and the concepts of quantum optics. Several examples taken from the scope of modern research are provided to emphasize the relevance of optics in current developments within science and technology. The text has been written for newcomers to the topic and benefits from the author's ability to explain difficult sequences and effects in a straightforward and easily comprehensible way. To this second, c

  13. Interactive virtual optical laboratories

    Science.gov (United States)

    Liu, Xuan; Yang, Yi

    2017-08-01

    Laboratory experiences are essential for optics education. However, college students have limited access to advanced optical equipment that is generally expensive and complicated. Hence there is a need for innovative solutions to expose students to advanced optics laboratories. Here we describe a novel approach, interactive virtual optical laboratory (IVOL) that allows unlimited number of students to participate the lab session remotely through internet, to improve laboratory education in photonics. Although students are not physically conducting the experiment, IVOL is designed to engage students, by actively involving students in the decision making process throughout the experiment.

  14. SPECIAL ASPECTS OF INITIAL OPTICAL SCHEME SELECTION FOR DESIGN OF NON-IMAGING OPTICAL SYSTEMS

    Directory of Open Access Journals (Sweden)

    R. V. Anitropov

    2016-01-01

    Full Text Available Subject of Research. The research results, structural composition analysis and the parametric synthesis of the projected imaging and non-imaging optical systems were presented. We made an attempt to use the gained experience about imaging systems while designing non-imaging systems, by adapting the composition theory for the calculations of non-imaging systems. Several patterns were revealed, which provide a deeper understanding of the design process of non-imaging optical systems; measures of its optimization were proposed. Method. We investigated the applicability of the theory of composition and synthesis of non-imaging optical systems. The main provisions of the theory of composition are based on the division of all available optical elements in four types depending on their functionality, which corresponds to a modular design. Similar items were identified in non-imaging optical systems and adaptation of composition theory to their design became possible. Main Results. General design patterns of imaging and non-imaging optical systems were studied. Classification of systems, components, as well as technical and generic characteristics of imaging and non-imaging optical systems was determined. Search mechanism of the initial optical system by means of structural and parametric synthesis of non-imaging optical system was formalized. The basic elements were determined included in non-imaging systems and their classification by functionality was done. They were subdivided into basic, corrective, wide angle and high aperture ones. The rules for formation of these elements and their composition were determined: surface reflecting, refracting, spherical and nonspherical elements with total internal reflection. The foundations of composition theory for non-imaging optical systems were laid. The approbation of this method was carried out on the example of the illumination system calculation for surgical room. A 3D model of an illumination optical

  15. Tumors of the optic nerve

    DEFF Research Database (Denmark)

    Lindegaard, Jens; Heegaard, Steffen

    2009-01-01

    A variety of lesions may involve the optic nerve. Mainly, these lesions are inflammatory or vascular lesions that rarely necessitate surgery but may induce significant visual morbidity. Orbital tumors may induce proptosis, visual loss, relative afferent pupillary defect, disc edema and optic...... atrophy, but less than one-tenth of these tumors are confined to the optic nerve or its sheaths. No signs or symptoms are pathognomonic for tumors of the optic nerve. The tumors of the optic nerve may originate from the optic nerve itself (primary tumors) as a proliferation of cells normally present...... in the nerve (e.g., astrocytes and meningothelial cells). The optic nerve may also be invaded from tumors originating elsewhere (secondary tumors), invading the nerve from adjacent structures (e.g., choroidal melanoma and retinoblastoma) or from distant sites (e.g., lymphocytic infiltration and distant...

  16. Ultralow power all-optical switch

    DEFF Research Database (Denmark)

    Nguyen, H.; Grange, T.; Reznychenko, B.

    2017-01-01

    Optical logic down to the single photon level holds the promise of data processing with a better energy efficiency than electronic devices [1]. In addition, preservation of quantum coherence in such logical components could lead to optical quantum logical gates [2--4]. Optical logic requires......-level systems coupled to light via a tailored photonic environment [8--13]. However optical logic requires two-mode non-linearities [14, 15]. Here we take advantage of the large coupling efficiency and the broadband operation of a photonic wire containing a semiconductor quantum dot (QD) [16] to implement...... an all-optical logical component, wherein as few as 10 photons per QD lifetime in one mode control the reflectivity of another, spectrally distinct, mode. Whether classical or quantum, optical communication has proven to be the best choice for long distance information distribution. All-optical data...

  17. Impact of climate change on fish population dynamics in the baltic sea: a dynamical downscaling investigation

    DEFF Research Database (Denmark)

    Mackenzie, Brian R; Meier, H E Markus; Lindegren, Martin

    2012-01-01

    Understanding how climate change, exploitation and eutrophication will affect populations and ecosystems of the Baltic Sea can be facilitated with models which realistically combine these forcings into common frameworks. Here, we evaluate sensitivity of fish recruitment and population dynamics...... and the temperature have influenced recruitment for at least 50 years. The three Baltic Sea models estimate relatively similar developments (increases) in biomass and fishery yield during twenty-first century climate change (ca. 28 % range among models). However, this uncertainty is exceeded by the one associated...... to past and future environmental forcings provided by three ocean-biogeochemical models of the Baltic Sea. Modeled temperature explained nearly as much variability in reproductive success of sprat (Sprattus sprattus; Clupeidae) as measured temperatures during 1973-2005, and both the spawner biomass...

  18. Optical biopsy of lymph node morphology using optical coherence tomography.

    Science.gov (United States)

    Luo, Wei; Nguyen, Freddy T; Zysk, Adam M; Ralston, Tyler S; Brockenbrough, John; Marks, Daniel L; Oldenburg, Amy L; Boppart, Stephen A

    2005-10-01

    Optical diagnostic imaging techniques are increasingly being used in the clinical environment, allowing for improved screening and diagnosis while minimizing the number of invasive procedures. Diffuse optical tomography, for example, is capable of whole-breast imaging and is being developed as an alternative to traditional X-ray mammography. While this may eventually be a very effective screening method, other optical techniques are better suited for imaging on the cellular and molecular scale. Optical Coherence Tomography (OCT), for instance, is capable of high-resolution cross-sectional imaging of tissue morphology. In a manner analogous to ultrasound imaging except using optics, pulses of near-infrared light are sent into the tissue while coherence-gated reflections are measured interferometrically to form a cross-sectional image of tissue. In this paper we apply OCT techniques for the high-resolution three-dimensional visualization of lymph node morphology. We present the first reported OCT images showing detailed morphological structure and corresponding histological features of lymph nodes from a carcinogen-induced rat mammary tumor model, as well as from a human lymph node containing late stage metastatic disease. The results illustrate the potential for OCT to visualize detailed lymph node structures on the scale of micrometastases and the potential for the detection of metastatic nodal disease intraoperatively.

  19. Springer handbook of lasers and optics

    CERN Document Server

    2012-01-01

    The Springer Handbook of Lasers and Optics provides fast, up-to-date, comprehensive and authoritative coverage of the wide fields of optics and lasers. It is written for daily use in the office or laboratory and offers explanatory text, data, and references needed for anyone working with lasers and optical instruments. This second edition features numerous updates and additions. Especially four new chapters on Fiber Optics, Integrated Optics, Frequency Combs, and Interferometry reflect the major changes. In addition, chapters Optical Materials and Their Properties, Optical Detectors, Nanooptics, and Optics far Beyond the Diffraction Limit have been thoroughly revised and updated. The now 25 chapters are grouped into four parts which cover basic principles and materials, fabrication and properties of optical components, coherent and incoherent light sources, and, finally, selected applications and special fields such as terahertz photonics, x-ray optics and holography. Each chapter is authored by respected exp...

  20. Optical logic gates based on electro-optic modulation with Sagnac interferometer.

    Science.gov (United States)

    Li, Qiliang; Zhu, Mengyun; Li, Dongqiang; Zhang, Zhen; Wei, Yizhen; Hu, Miao; Zhou, Xuefang; Tang, Xianghong

    2014-07-20

    In this work, we present a new structure to realize optical logic operation in a Sagnac interferometer with electro-optical modulation. In the scheme, we divide two counterpropagation signals in a Sagnac loop to two different arms with the electro-optical crystal by using two circulators. Lithium niobate materials whose electro-optical coefficient can be as large as 32.2×10(-12)  m/V make up the arms of the waveguides. Using the transfer matrix of the fiber coupler, we analyze the propagation of signals in this system and obtain the transmission characteristic curves and the extinction ratio. The results indicate that this optical switching has a high extinction ratio of about 60 dB and an ultrafast response time of 2.036 ns. In addition, the results reveal that the change of the dephasing between the two input signals and the modification of the modulation voltage added to the electro-optical crystal leads to the change of the extinction ratio. We also conclude that, in cases of the dephasing of two initial input signals Δφ=0, we can obtain the various logical operations, such as the logical operations D=A¯·B, D=A·B¯, C=A+B, and D=A⊕B in ports C and D of the system by adjusting the modulation voltage. When Δφ≠0, we obtain the arithmetic operations D=A+B, C=A⊕B, D=A·B¯, and C=A¯·B in ports C and D. This study is significant for the design of all optical networks by adjusting the modulation voltage.