WorldWideScience

Sample records for clinically relevant doses

  1. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    International Nuclear Information System (INIS)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A.

    2011-01-01

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa. Conclusions: There is a lack of correlation between

  2. Effects of clinically relevant doses of methyphenidate on spatial memory, behavioral sensitization and open field habituation: a time related study.

    Science.gov (United States)

    Haleem, Darakhshan Jabeen; Inam, Qurrat-ul-Aen; Haleem, Muhammad Abdul

    2015-03-15

    The psychostimulant methylphenidate (MPD) is a first-line drug for the treatment of attention deficit hyperactivity disorder (ADHD). Despite acceptable therapeutic efficacy, there is limited data regarding the long-term consequences of MPD exposure over extended periods. The present study concerns effects of clinically relevant doses of MPD, administered orally to rats for an extended period, on spatial memory, behavioral sensitization and habituation to an open field. Water maze test was used to monitor memory acquisition (2 h after training), retention (day next to training), extinction (1 week after training) and reconsolidation (weekly for 4 weeks). Administration of MPD at doses of 0.25-1.0 mg/kg improved memory acquisition, retention, reconsolidation and impaired memory extinction. Treatment with 0.25 and 0.5 mg/kg MPD for 6 weeks produced a sustained increase in motor activity but higher dose (1.0 mg/kg) elicited behavioral sensitization. High as well as low doses MPD impaired open field habituation. We conclude that clinically relevant doses of MPD enhance memory even if used for extended period. It is suggested that higher (1.0 mg/kg) clinically relevant doses of MPD, if used for extended period, may exacerbate hyperactivity and impulsivity associated with the disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A. [Canis Lupus LLC and Department of Human Oncology, University of Wisconsin, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Departments of Human Oncology, Medical Physics, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-02-15

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa

  4. The effects of clinically relevant doses of amphetamine and methylphenidate on signal detection and DRL in rats

    Science.gov (United States)

    Andrzejewski, Matthew E.; Spencer, Robert C.; Harris, Rachel L.; Feit, Elizabeth C.; McKee, Brenda L.; Berridge, Craig W.

    2014-01-01

    Low dose amphetamine (AMPH) and methylphenidate (MPH, Ritalin®) are the most widely prescribed and most effective pharmacotherapy for attention-deficit/hyperactivity disorder (ADHD). Certain low, clinically relevant doses of MPH improve sustained attention and working memory in normal rats, in contrast to higher doses that impair cognitive ability and induce locomotor activity. However, the effects of AMPH of MPH on sustained attention and behavioral inhibition remain poorly characterized. The present experiments examined the actions of AMPH (0.1 and 0.25 mg/kg) and MPH (0.5 and 1.0 mg/kg) in a rat model of 1) sustained attention, where signal and blank trials were interspersed randomly and occurred at unpredictable times, and 2) behavioral inhibition, using a differential reinforcement of low rate (DRL) schedule. In a signal detection paradigm, both 0.5 mg/kg and 1.0 mg/kg MPH and 0.25 mg/kg AMPH improve sustained attention, however neither AMPH nor MPH improve behavioral inhibition on DRL. Taken together with other recent studies, it appears that clinically-relevant doses of AMPH and MPH may preferentially improve attention-related behavior while having little effect on behavioral inhibition. These observations provide additional insight into the basic behavioral actions of low-dose psychostimulants and further suggest that the use of sustained attention tasks may be important in the development of novel pharmacological treatments for ADHD. PMID:24467844

  5. Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field Configurations

    International Nuclear Information System (INIS)

    Wroe, Andrew; Clasie, Ben; Kooy, Hanne; Flanz, Jay; Schulte, Reinhard; Rosenfeld, Anatoly

    2009-01-01

    Purpose: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. Methods and Materials: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement from the treatment field edge and distance downstream of the beam's distal edge. Results: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. Conclusions: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields

  6. PROFOUND AND SEXUALLY DIMORPHIC EFFECTS OF CLINICALLY-RELEVANT LOW DOSE SCATTER IRRADIATION ON THE BRAIN AND BEHAVIOR

    Directory of Open Access Journals (Sweden)

    Anna eKovalchuk

    2016-06-01

    Full Text Available Irradiated cells can signal damage and distress to both close and distant neighbors that have not been directly exposed to the radiation (naïve bystanders. While studies have shown that such bystander effects occur in the shielded brain of animals upon body irradiation, their mechanism remains unexplored. Observed effects may be caused by some blood-borne factors; however they may also be explained, at least in part, by very small direct doses received by the brain that result from scatter or leakage. In order to establish the roles of low doses of scatter irradiation in the brain response, we developed a new model for scatter irradiation analysis whereby one rat was irradiated directly at the liver and the second rat was placed adjacent to the first and received a scatter dose to its body and brain. This work focuses specifically on the response of the latter rat brain to the low scatter irradiation dose. Here, we provide the first experimental evidence that very low, clinically relevant doses of scatter irradiation alter gene expression, induce changes in dendritic morphology, and lead to behavioral deficits in exposed animals. The results showed that exposure to radiation doses as low as 0.115 cGy caused changes in gene expression and reduced spine density, dendritic complexity, and dendritic length in the prefrontal cortex tissues of females, but not males. In the hippocampus, radiation altered neuroanatomical organization in males, but not in females. Moreover, low dose radiation caused behavioral deficits in the exposed animals. This is the first study to show that low dose scatter irradiation influences the brain and behavior in a sex-specific way.

  7. Biologically effective dose distribution based on the linear quadratic model and its clinical relevance

    International Nuclear Information System (INIS)

    Lee, Steve P.; Leu, Min Y.; Smathers, James B.; McBride, William H.; Parker, Robert G.; Withers, H. Rodney

    1995-01-01

    Purpose: Radiotherapy plans based on physical dose distributions do not necessarily entirely reflect the biological effects under various fractionation schemes. Over the past decade, the linear-quadratic (LQ) model has emerged as a convenient tool to quantify biological effects for radiotherapy. In this work, we set out to construct a mechanism to display biologically oriented dose distribution based on the LQ model. Methods and Materials: A computer program that converts a physical dose distribution calculated by a commercially available treatment planning system to a biologically effective dose (BED) distribution has been developed and verified against theoretical calculations. This software accepts a user's input of biological parameters for each structure of interest (linear and quadratic dose-response and repopulation kinetic parameters), as well as treatment scheme factors (number of fractions, fractional dose, and treatment time). It then presents a two-dimensional BED display in conjunction with anatomical structures. Furthermore, to facilitate clinicians' intuitive comparison with conventional fractionation regimen, a conversion of BED to normalized isoeffective dose (NID) is also allowed. Results: Two sample cases serve to illustrate the application of our tool in clinical practice. (a) For an orthogonal wedged pair of x-ray beams treating a maxillary sinus tumor, the biological effect at the ipsilateral mandible can be quantified, thus illustrates the so-called 'double-trouble' effects very well. (b) For a typical four-field, evenly weighted prostate treatment using 10 MV x-rays, physical dosimetry predicts a comparable dose at the femoral necks between an alternate two-fields/day and four-fields/day schups. However, our BED display reveals an approximate 21% higher BED for the two-fields/day scheme. This excessive dose to the femoral necks can be eliminated if the treatment is delivered with a 3:2 (anterio-posterior/posterio-anterior (AP

  8. Utilization of a novel electrochemical {sup 90}Sr/{sup 90}Y generator for the preparation of {sup 90}Y-labeled RGD peptide dimer in clinically relevant dose

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Chakravarty, Rubel; Pillai, Maroor Raghavan Ambikalmajan; Dash, Ashutosh [Bhabha Atomic Research Centre, Mumbai (India). Radiopharmaceuticals Div.; Sarma, Haladhar Dev [Bhabha Atomic Research Centre, Mumbai (India). Radiation Biology and Health Sciences Div.

    2014-09-01

    The work reported in this paper provides a systematic study towards the development of an optimized strategy for preparation of a clinically relevant dose of {sup 90}Y-labeled dimeric RGD peptide derivative, DOTA-E[c(RGDfK)]{sub 2} [DOTA-(RGD){sub 2}] for in vivo targeted therapy utilizing {sup 90}Y obtained from a novel electrochemical {sup 90}Sr/{sup 90}Y generator. The performance of the generator was evaluated to ensure its suitability for providing {sup 90}Y in adequate quantity and purity required for formulation of clinically relevant dose for PRRT. {sup 90}Y-DOTA-(RGD){sub 2} was synthesized in high yield (86.2 ± 2.5%) and radiochemical purity (98.4 ± 0.5%) using clinically relevant dose (∝ 3.8 GBq) of {sup 90}Y. In vitro stability studies revealed that the radiolabeled conjugate retained its radiochemical purity in normal saline and human serum. Preliminary biodistribution studies carried out in C57/BL6 mice bearing melanoma tumors showed that the preparation exhibited significant tumor uptake (5.30 ± 0.78% of injected activity at 30 min post-injection) with good tumor to background ratio. The optimized radiolabeling protocol seems to be an attractive strategy which is largely viewed as a springboard to realize scope of developing {sup 90}Y labeled cyclic RGD peptides for targeted therapy of tumors over-expressing integrin-α{sub ν}β{sub 3} receptors. (orig.)

  9. Intensity modulated radiation therapy (IMRT: differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma

    Directory of Open Access Journals (Sweden)

    Delclos Marc E

    2011-06-01

    Full Text Available Abstract Background A strong dose-volume relationship exists between the amount of small bowel receiving low- to intermediate-doses of radiation and the rates of acute, severe gastrointestinal toxicity, principally diarrhea. There is considerable interest in the application of highly conformal treatment approaches, such as intensity-modulated radiation therapy (IMRT, to reduce dose to adjacent organs-at-risk in the treatment of carcinoma of the rectum. Therefore, we performed a comprehensive dosimetric evaluation of IMRT compared to 3-dimensional conformal radiation therapy (3DCRT in standard, preoperative treatment for rectal cancer. Methods Using RTOG consensus anorectal contouring guidelines, treatment volumes were generated for ten patients treated preoperatively at our institution for rectal carcinoma, with IMRT plans compared to plans derived from classic anatomic landmarks, as well as 3DCRT plans treating the RTOG consensus volume. The patients were all T3, were node-negative (N = 1 or node-positive (N = 9, and were planned to a total dose of 45-Gy. Pairwise comparisons were made between IMRT and 3DCRT plans with respect to dose-volume histogram parameters. Results IMRT plans had superior PTV coverage, dose homogeneity, and conformality in treatment of the gross disease and at-risk nodal volume, in comparison to 3DCRT. Additionally, in comparison to the 3DCRT plans, IMRT achieved a concomitant reduction in doses to the bowel (small bowel mean dose: 18.6-Gy IMRT versus 25.2-Gy 3DCRT; p = 0.005, bladder (V40Gy: 56.8% IMRT versus 75.4% 3DCRT; p = 0.005, pelvic bones (V40Gy: 47.0% IMRT versus 56.9% 3DCRT; p = 0.005, and femoral heads (V40Gy: 3.4% IMRT versus 9.1% 3DCRT; p = 0.005, with an improvement in absolute volumes of small bowel receiving dose levels known to induce clinically-relevant acute toxicity (small bowel V15Gy: 138-cc IMRT versus 157-cc 3DCRT; p = 0.005. We found that the IMRT treatment volumes were typically larger than that

  10. Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young-Min; Xia Zhidao; Glyn-Jones, Sion; Beard, David; Gill, Harinderjit S; Murray, David W, E-mail: young-min.kwon@ndos.ox.ac.u [Nuffield Department of Orthopaedic Surgery, University of Oxford, Oxford OX3 7LD (United Kingdom)

    2009-04-15

    Despite the satisfactory short-term implant survivorship of metal-on-metal hip resurfacing arthroplasty, periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. Cytotoxic effects of cobalt or chromium have been suggested to play a role in its aetiology. The aim of this study was to investigate the effects of clinically relevant metal nanoparticles and ions on the viability of macrophages in vitro. A RAW 264.7 murine macrophage cell line was cultured in the presence of either: (1) cobalt, chromium and titanium nanoparticles sized 30-35 nm; or (2) cobalt sulphate and chromium chloride. Two methods were used to quantify cell viability: Alamar Blue assay and Live/Dead assay. The cytotoxicity was observed only with cobalt. Cobalt nanoparticles and ions demonstrated dose-dependent cytotoxic effects on macrophages in vitro: the cytotoxic concentrations of nanoparticles and ions were 1 x 10{sup 12} particles ml{sup -1} and 1000 {mu}M, respectively. The high concentration of cobalt nanoparticles required for cytotoxicity of macrophages in vitro suggests that increased production of cobalt nanoparticles in vivo, due to excessive MoM implant wear, may lead to local adverse biological effects. Therefore, cytotoxicity of high concentrations of metal nanoparticles phagocytosed by macrophages located in the periprosthetic tissues may be an important factor in pathogenesis of pseudotumours.

  11. Theoretical analysis of the dose dependence of the oxygen enhancement ratio and its relevance for clinical applications

    International Nuclear Information System (INIS)

    Wenzl, Tatiana; Wilkens, Jan J

    2011-01-01

    The increased resistance of hypoxic cells to ionizing radiation is usually believed to be the primary reason for treatment failure in tumors with oxygen-deficient areas. This oxygen effect can be expressed quantitatively by the oxygen enhancement ratio (OER). Here we investigate theoretically the dependence of the OER on the applied local dose for different types of ionizing irradiation and discuss its importance for clinical applications in radiotherapy for two scenarios: small dose variations during hypoxia-based dose painting and larger dose changes introduced by altered fractionation schemes. Using the widespread Alper-Howard-Flanders and standard linear-quadratic (LQ) models, OER calculations are performed for T1 human kidney and V79 Chinese hamster cells for various dose levels and various hypoxic oxygen partial pressures (pO2) between 0.01 and 20 mmHg as present in clinical situations in vivo. Our work comprises the analysis for both low linear energy transfer (LET) treatment with photons or protons and high-LET treatment with heavy ions. A detailed analysis of experimental data from the literature with respect to the dose dependence of the oxygen effect is performed, revealing controversial opinions whether the OER increases, decreases or stays constant with dose. The behavior of the OER with dose per fraction depends primarily on the ratios of the LQ parameters alpha and beta under hypoxic and aerobic conditions, which themselves depend on LET, pO2 and the cell or tissue type. According to our calculations, the OER variations with dose in vivo for low-LET treatments are moderate, with changes in the OER up to 11% for dose painting (1 or 3 Gy per fraction compared to 2 Gy) and up to 22% in hyper-/hypofractionation (0.5 or 20 Gy per fraction compared to 2 Gy) for oxygen tensions between 0.2 and 20 mmHg typically measured clinically in hypoxic tumors. For extremely hypoxic cells (0.01 mmHg), the dose dependence of the OER becomes more pronounced (up to 36

  12. Comparison of early treatment with low doses of nilotinib, imatinib and a clinically relevant dose of silymarin in thioacetamide-induced liver fibrosis.

    Science.gov (United States)

    Shaker, Mohamed E; Shiha, Gamal E; Ibrahim, Tarek M

    2011-11-30

    Our previous study has already confirmed a promising anti-fibrotic activity especially for nilotinib; when given at a daily dose of 10 mg/kg during the last 4 weeks of thioacetamide (TAA)-induced liver fibrosis for 12 weeks in rats. Therefore, this study was carried out to compare the prophylactic potential of low dose of nilotinib to that of its predecessor, imatinib, and a clinically relevant dose of the standard hepatoprotective treatment, silymarin, in TAA-intoxication. Male Wistar rats received intraperitoneal injections of TAA (150 mg/kg, twice weekly) for 8 weeks, as well as oral treatments with imatinib (5 mg/kg/day), nilotinib (5 mg/kg/day) and silymarin (50 mg/kg/day) from the first day of TAA-intoxication. At the end of the study, chronic hepatic injury was evaluated by analysis of liver function tests in serum. Hepatic oxidative stress was assessed by measuring malondialdehyde, 4-hydroxynonenal, total nitrate/nitrite and reduced glutathione contents, as well as myeloperoxidase and superoxide dismutase activities. Hepatic fibrosis was evaluated by histopathology and collagen content. Our results suggest that the prophylactic potential of nilotinib (5 mg/kg/day), imatinib (5mg/kg/day) and silymarin (50 mg/kg/day) in TAA-intoxication for 8 weeks is lower than the late treatments of nilotinib (10 mg/kg/day), imatinib (10mg/kg/day) and silymarin (100 mg/kg/day) during the last 4 weeks of TAA-intoxication for 12 weeks in rats. Taken together, this study suggests that nilotinib may have higher anti-fibrotic activity when administered at a significant stage of fibrosis as a result of impairment of its metabolism in the fibrotic livers. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Clinical relevance in anesthesia journals

    DEFF Research Database (Denmark)

    Lauritsen, Jakob; Møller, Ann M

    2006-01-01

    The purpose of this review is to present the latest knowledge and research on the definition and distribution of clinically relevant articles in anesthesia journals. It will also discuss the importance of the chosen methodology and outcome of articles.......The purpose of this review is to present the latest knowledge and research on the definition and distribution of clinically relevant articles in anesthesia journals. It will also discuss the importance of the chosen methodology and outcome of articles....

  14. A meta-analysis of the abscopal effect in preclinical models: Is the biologically effective dose a relevant physical trigger?

    Directory of Open Access Journals (Sweden)

    Raffaella Marconi

    Full Text Available Preclinical in vivo studies using small animals are considered crucial in translational cancer research and clinical implementation of novel treatments. This is of paramount relevance in radiobiology, especially for any technological developments permitted to deliver high doses in single or oligo-fractionated regimens, such as stereotactic ablative radiotherapy (SABR. In this context, clinical success in cancer treatment needs to be guaranteed, sparing normal tissue and preventing the potential spread of disease or local recurrence. In this work we introduce a new dose-response relationship based on relevant publications concerning preclinical models with regard to delivered dose, fractionation schedule and occurrence of biological effects on non-irradiated tissue, abscopal effects.We reviewed relevant publications on murine models and the abscopal effect in radiation cancer research following PRISMA methodology. In particular, through a log-likelihood method, we evaluated whether the occurrence of abscopal effects may be related to the biologically effective dose (BED. To this aim, studies accomplished with different tumor histotypes were considered in our analysis including breast, colon, lung, fibrosarcoma, pancreas, melanoma and head and neck cancer. For all the tumors, the α / β ratio was assumed to be 10 Gy, as generally adopted for neoplastic cells.Our results support the hypothesis that the occurrence rate of abscopal effects in preclinical models increases with BED. In particular, the probability of revealing abscopal effects is 50% when a BED of 60 Gy is generated.Our study provides evidence that SABR treatments associated with high BEDs could be considered an effective strategy in triggering the abscopal effect, thus shedding light on the promising outcomes revealed in clinical practice.

  15. Metabolism of psilocybin and psilocin: clinical and forensic toxicological relevance.

    Science.gov (United States)

    Dinis-Oliveira, Ricardo Jorge

    2017-02-01

    Psilocybin and psilocin are controlled substances in many countries. These are the two main hallucinogenic compounds of the "magic mushrooms" and both act as agonists or partial agonists at 5-hydroxytryptamine (5-HT) 2A subtype receptors. During the last few years, psilocybin and psilocin have gained therapeutic relevance but considerable physiological variability between individuals that can influence dose-response and toxicological profile has been reported. This review aims to discuss metabolism of psilocybin and psilocin, by presenting all major and minor psychoactive metabolites. Psilocybin is primarily a pro-drug that is dephosphorylated by alkaline phosphatase to active metabolite psilocin. This last is then further metabolized, psilocin-O-glucuronide being the main urinary metabolite with clinical and forensic relevance in diagnosis.

  16. Dose-response relationship in clinical oncology

    International Nuclear Information System (INIS)

    Gehan, E.A.

    1984-01-01

    The relationship of dose (and dose rate) to response and toxicity in clinical oncology is reviewed. The concepts expressed by some authors in dose-response studies in animal and human systems are reviewed briefly. Dose rate and tactics of conducting clinical studies are reviewed for both radiotherapy and various types of chemotherapeutic treatment. Examples are given from clinical studies in Hodgkin's disease, acute leukemia, and breast cancer that may prove useful in planning future clinical studies

  17. Accelerated partial-breast irradiation with interstitial implants. The clinical relevance of the calculation of skin doses

    International Nuclear Information System (INIS)

    Ott, O.J.; Lotter, M.; Sauer, R.; Strnad, V.

    2007-01-01

    Purpose: To describe relative skin dose estimations and their impact on cosmetic outcome in interstitial multicatheter accelerated partial-breast irradiation (APBI). Patients and Methods: Between April 2001 and January 2005, 105 consecutive patients with early breast cancer were recruited in Erlangen, Germany, for this substudy of the German-Austrian APBI phase II trial. 51% (54/105) received pulsed-dose-rate (PDR), and 49% (51/105) high-dose-rate (HDR) brachytherapy. Prescribed reference dose for HDR brachytherapy was 32 Gy in eight fractions of 4 Gy, twice daily. Prescribed reference dose in PDR brachytherapy was 49.8 Gy in 83 consecutive fractions of 0.6 Gy every hour. Total treatment time was 3-4 days. With a wire cross on the skin surface during the brachytherapy-planning procedure the minimal, mean and maximal relative skin doses (SD min% , SD max% , SD mean% ) were recorded. Endpoint of this evaluation was the cosmetic outcome in relation to the relative skin doses. Results: Median follow-up time was 38 months (range, 19-65 months). Cosmetic results for all patients were excellent in 57% (60/105), good in 36% (38/105), and fair in 7% (7/105). The SD min% (27.0% vs. 31.7%; p = 0.032), SD mean% (34.2% vs. 38.1%; p 0.008), and SD max% (38.2% vs. 46.4%; p 0.003) were significantly lower for patients with excellent cosmetic outcome compared to patients with a suboptimal outcome. SD mean% (37.6% vs. 34.2%; p = 0.026) and SD max% (45.4% vs. 38.2%; p = 0.008) were significantly higher for patients with good cosmetic outcome compared with the patients with excellent results. Conclusion: The appraisal of skin doses has been shown to be relevant to the achievement of excellent cosmetic outcome. Further investigations are necessary, especially on the basis of CT-based brachytherapy planning, to further improve the treatment results of multicatheter APBI. (orig.)

  18. Clinically relevant incidental cardiovascular findings in CT examinations

    International Nuclear Information System (INIS)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A.; Schramm, D.; Bach, A.G.

    2017-01-01

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [de

  19. Overexpression of caveolin-1 in lymphoblastoid TK6 cells enhances proliferation after irradiation with clinically relevant doses

    International Nuclear Information System (INIS)

    Barzan, David; Maier, Patrick; Wenz, Frederik; Herskind, Carsten; Zeller, W. Jens

    2010-01-01

    Background and Purpose: The transmembrane protein caveolin-1 (CAV1) is an essential component of caveolae, small membrane invaginations involved in vesicle formation. CAV1 plays a role in signal transduction, tumor suppression and oncogene transformation. Previous studies with CAV1 knockout mice and CAV1 knockdown in pancreatic tumor cells implicated CAV1 in mediating radioresistance. The aim of this work was to test the effect of CAV1 overexpression after irradiation in human cells lacking endogenous CAV1 expression. Material and Methods: Human CAV1 was overexpressed in lymphoblastoid TK6 cells (TK6-wt) using a eukaryotic expression plasmid, pCI-CAV1, or a lentiviral SIN (self-inactivating) vector, HR'SIN-CAV1. CAV1 expression was verified in TK6 cells with Western blot analysis or intracellular FACS (fluorescence-activated cell sorting) staining. The effect of CAV1 on proliferation kinetics after irradiation of TK6 cells was measured with a growth assay. Results: TK6-wt showed no detectable endogenous CAV1 expression. Lentivirally mediated transduction with HR'SIN-CAV1 (TK6-CAV1) resulted in a considerably stronger CAV1 expression in comparison to TK6 cells electroporated with pCI-CAV1. Intracellular FACS analysis showed that 90% of transduced cells expressed CAV1. CAV1 enhanced early proliferation of TK6 cells after irradiation with a dose of 2 Gy, whereas proliferation of unirradiated cells was not affected. CAV1 also protected cells after irradiation with 4 Gy. This radioprotective effect was supported by a reduction of radiation-induced apoptosis. Conclusion: A model system for expression of exogenous CAV1 by stable lentiviral transduction of TK6 cells was established. Functional assays demonstrated enhanced early proliferation by CAV1 expression in TK6 cells after irradiation with clinically relevant doses supporting the role of CAV1 as a prosurvival factor. (orig.)

  20. Application of organ tolerance dose-constraints in clinical studies in radiation oncology

    International Nuclear Information System (INIS)

    Doerr, Wolfgang; Herrmann, Thomas; Baumann, Michael

    2014-01-01

    In modern radiation oncology, tolerance dose-constraints for organs at risk (OAR) must be considered for treatment planning, but particularly in order to design clinical studies. Tolerance dose tables, however, only address one aspect of the therapeutic ratio of any clinical study, i.e., the limitation of adverse events, but not the desired potential improvement in the tumor effect of a novel treatment strategy. A sensible application of ''tolerance doses'' in a clinical situation requires consideration of various critical aspects addressed here: definition of tolerance dose, specification of an endpoint/symptom, consideration of radiation quality and irradiation protocol, exposed volume and dose distribution, and patient-related factors of radiosensitivity. The currently most comprehensive estimates of OAR radiation tolerance are in the QUANTEC compilations (2010). However, these tolerance dose values must only be regarded as a rough orientation and cannot answer the relevant question for the patients, i.e., if the study can achieve a therapeutic advantage; this can obviously be answered only by the final scientific analysis of the study results. Despite all limitations, the design of clinical studies should currently refer to the QUANTEC values for appreciation of the risk of complications, if needed supplemented by one's own data or further information from the literature. The implementation of a consensus on the safety interests of the patients and on an application and approval process committed to progress in medicine, with transparent quality-assuring requirements with regard to the structural safeguarding of the study activities, plays a central role in clinical research in radiation oncology. (orig.) [de

  1. Clinical Relevance of Adipokines

    Directory of Open Access Journals (Sweden)

    Matthias Blüher

    2012-10-01

    Full Text Available The incidence of obesity has increased dramatically during recent decades. Obesity increases the risk for metabolic and cardiovascular diseases and may therefore contribute to premature death. With increasing fat mass, secretion of adipose tissue derived bioactive molecules (adipokines changes towards a pro-inflammatory, diabetogenic and atherogenic pattern. Adipokines are involved in the regulation of appetite and satiety, energy expenditure, activity, endothelial function, hemostasis, blood pressure, insulin sensitivity, energy metabolism in insulin sensitive tissues, adipogenesis, fat distribution and insulin secretion in pancreatic β-cells. Therefore, adipokines are clinically relevant as biomarkers for fat distribution, adipose tissue function, liver fat content, insulin sensitivity, chronic inflammation and have the potential for future pharmacological treatment strategies for obesity and its related diseases. This review focuses on the clinical relevance of selected adipokines as markers or predictors of obesity related diseases and as potential therapeutic tools or targets in metabolic and cardiovascular diseases.

  2. Overexpression of caveolin-1 in lymphoblastoid TK6 cells enhances proliferation after irradiation with clinically relevant doses

    Energy Technology Data Exchange (ETDEWEB)

    Barzan, David; Maier, Patrick; Wenz, Frederik; Herskind, Carsten [Dept. of Radiation Oncology, Univ. Medical Center Mannheim, Univ. of Heidelberg, Mannheim (Germany); Zeller, W. Jens [Pharmacology of Cancer Treatment, German Cancer Research Center, Heidelberg (Germany)

    2010-02-15

    Background and Purpose: The transmembrane protein caveolin-1 (CAV1) is an essential component of caveolae, small membrane invaginations involved in vesicle formation. CAV1 plays a role in signal transduction, tumor suppression and oncogene transformation. Previous studies with CAV1 knockout mice and CAV1 knockdown in pancreatic tumor cells implicated CAV1 in mediating radioresistance. The aim of this work was to test the effect of CAV1 overexpression after irradiation in human cells lacking endogenous CAV1 expression. Material and Methods: Human CAV1 was overexpressed in lymphoblastoid TK6 cells (TK6-wt) using a eukaryotic expression plasmid, pCI-CAV1, or a lentiviral SIN (self-inactivating) vector, HR'SIN-CAV1. CAV1 expression was verified in TK6 cells with Western blot analysis or intracellular FACS (fluorescence-activated cell sorting) staining. The effect of CAV1 on proliferation kinetics after irradiation of TK6 cells was measured with a growth assay. Results: TK6-wt showed no detectable endogenous CAV1 expression. Lentivirally mediated transduction with HR'SIN-CAV1 (TK6-CAV1) resulted in a considerably stronger CAV1 expression in comparison to TK6 cells electroporated with pCI-CAV1. Intracellular FACS analysis showed that 90% of transduced cells expressed CAV1. CAV1 enhanced early proliferation of TK6 cells after irradiation with a dose of 2 Gy, whereas proliferation of unirradiated cells was not affected. CAV1 also protected cells after irradiation with 4 Gy. This radioprotective effect was supported by a reduction of radiation-induced apoptosis. Conclusion: A model system for expression of exogenous CAV1 by stable lentiviral transduction of TK6 cells was established. Functional assays demonstrated enhanced early proliferation by CAV1 expression in TK6 cells after irradiation with clinically relevant doses supporting the role of CAV1 as a prosurvival factor. (orig.)

  3. Detecting clinically relevant new information in clinical notes across specialties and settings.

    Science.gov (United States)

    Zhang, Rui; Pakhomov, Serguei V S; Arsoniadis, Elliot G; Lee, Janet T; Wang, Yan; Melton, Genevieve B

    2017-07-05

    Automated methods for identifying clinically relevant new versus redundant information in electronic health record (EHR) clinical notes is useful for clinicians and researchers involved in patient care and clinical research, respectively. We evaluated methods to automatically identify clinically relevant new information in clinical notes, and compared the quantity of redundant information across specialties and clinical settings. Statistical language models augmented with semantic similarity measures were evaluated as a means to detect and quantify clinically relevant new and redundant information over longitudinal clinical notes for a given patient. A corpus of 591 progress notes over 40 inpatient admissions was annotated for new information longitudinally by physicians to generate a reference standard. Note redundancy between various specialties was evaluated on 71,021 outpatient notes and 64,695 inpatient notes from 500 solid organ transplant patients (April 2015 through August 2015). Our best method achieved at best performance of 0.87 recall, 0.62 precision, and 0.72 F-measure. Addition of semantic similarity metrics compared to baseline improved recall but otherwise resulted in similar performance. While outpatient and inpatient notes had relatively similar levels of high redundancy (61% and 68%, respectively), redundancy differed by author specialty with mean redundancy of 75%, 66%, 57%, and 55% observed in pediatric, internal medicine, psychiatry and surgical notes, respectively. Automated techniques with statistical language models for detecting redundant versus clinically relevant new information in clinical notes do not improve with the addition of semantic similarity measures. While levels of redundancy seem relatively similar in the inpatient and ambulatory settings in the Fairview Health Services, clinical note redundancy appears to vary significantly with different medical specialties.

  4. The estimation of effective doses using measurement of several relevant physical parameters from radon exposures

    International Nuclear Information System (INIS)

    Ridzikova, A; Fronka, A.; Maly, B.; Moucka, L.

    2003-01-01

    In the present investigation, we will be study the dose relevant factors from continual monitoring in real homes into account getting more accurate estimation of 222 Rn the effective dose. The dose relevant parameters include the radon concentration, the equilibrium factor (f), the fraction (fp) of unattached radon decay products and real time occupancy people in home. The result of the measurement are the time courses of radon concentration that are based on estimation effective doses together with assessment of the real time occupancy people indoor. We found out by analysis that year effective dose is lower than effective dose estimated by ICRP recommendation from the integral measurement that included only average radon concentration. Our analysis of estimation effective doses using measurement of several physical parameters was made only in one case and for the better specification is important to measure in different real occupancy houses. (authors)

  5. Valerian: No Evidence for Clinically Relevant Interactions

    Directory of Open Access Journals (Sweden)

    Olaf Kelber

    2014-01-01

    Full Text Available In recent popular publications as well as in widely used information websites directed to cancer patients, valerian is claimed to have a potential of adverse interactions with anticancer drugs. This questions its use as a safe replacement for, for example, benzodiazepines. A review on the interaction potential of preparations from valerian root (Valeriana officinalis L. root was therefore conducted. A data base search and search in a clinical drug interaction data base were conducted. Thereafter, a systematic assessment of publications was performed. Seven in vitro studies on six CYP 450 isoenzymes, on p-glycoprotein, and on two UGT isoenzymes were identified. However, the methodological assessment of these studies did not support their suitability for the prediction of clinically relevant interactions. In addition, clinical studies on various valerian preparations did not reveal any relevant interaction potential concerning CYP 1A2, 2D6, 2E1, and 3A4. Available animal and human pharmacodynamic studies did not verify any interaction potential. The interaction potential of valerian preparations therefore seems to be low and thereby without clinical relevance. We conclude that there is no specific evidence questioning their safety, also in cancer patients.

  6. Clinical relevance of findings in trials of CBT for depression

    NARCIS (Netherlands)

    Lepping, P.; Whittington, R.; Sambhi, R.S.; Lane, S.; Poole, R.; Leucht, S.; Cuijpers, P.; McCabe, R.; Waheed, W.

    2017-01-01

    Cognitive behavioural therapy (CBT) is beneficial in depression. Symptom scores can be translated into Clinical Global Impression (CGI) scale scores to indicate clinical relevance. We aimed to assess the clinical relevance of findings of randomised controlled trials (RCTs) of CBT in depression. We

  7. Entyvio lengthen dose-interval study: lengthening vedolizumab dose interval and the risk of clinical relapse in inflammatory bowel disease.

    Science.gov (United States)

    Chan, Webber; Lynch, Nicole; Bampton, Peter; Chang, Jeff; Chung, Alvin; Florin, Timothy; Hetzel, David J; Jakobovits, Simon; Moore, Gregory; Pavli, Paul; Radford-Smith, Graham; Thin, Lena; Baraty, Brandon; Haifer, Craig; Yau, Yunki; Leong, Rupert W L

    2018-07-01

    Vedolizumab (VDZ), an α4β7 anti-integrin antibody, is efficacious in the induction and maintenance of remission in ulcerative colitis (UC) and Crohn's disease (CD). In the GEMINI long-term safety study, enrolled patients received 4-weekly VDZ. Upon completion, patients were switched to 8-weekly VDZ in Australia. The clinical success rate of treatment de-escalation for patients in remission on VDZ has not been described previously. To determine the proportion of patients who relapsed after switching from 4 to 8-weekly VDZ, the mean time to relapse, and the recapture rate when switching back to 8-weekly dosing. This was a retrospective, observational, multicenter study of patients previously recruited into GEMINI long-term safety in Australia. Data on the demographics and biochemical findings were collected. There were 34 patients [23 men, mean age 49.1 (±13.1) years] and their mean disease duration was 17.6 (±8.5) years. The mean 4-weekly VDZ infusion duration was 286.5 (±48.8) weeks. A total of five (15%) patients relapsed on dose-interval increase (4/17 UC, 1/17 CD) at a median duration from dose interval lengthening to flare of 14 weeks (interquartile range=6-25). Eighty percent (4/5) of patients re-entered remission following dose-interval decrease back to 4-weekly. No clinical predictors of relapse could be determined because of the small cohort size. The risk of patients relapsing when switching from 4 to 8-weekly VDZ ∼15% and is similar between CD and UC. Dose-interval decrease recaptures 80% of patients who relapsed. Therapeutic drug monitoring of VDZ may be of clinical relevance.

  8. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  9. Clinical relevance of findings in trials of CBT for depression.

    Science.gov (United States)

    Lepping, P; Whittington, R; Sambhi, R S; Lane, S; Poole, R; Leucht, S; Cuijpers, P; McCabe, R; Waheed, W

    2017-09-01

    Cognitive behavioural therapy (CBT) is beneficial in depression. Symptom scores can be translated into Clinical Global Impression (CGI) scale scores to indicate clinical relevance. We aimed to assess the clinical relevance of findings of randomised controlled trials (RCTs) of CBT in depression. We identified RCTs of CBT that used the Hamilton Rating Scale for Depression (HAMD). HAMD scores were translated into Clinical Global Impression - Change scale (CGI-I) scores to measure clinical relevance. One hundred and seventy datasets from 82 studies were included. The mean percentage HAMD change for treatment arms was 53.66%, and 29.81% for control arms, a statistically significant difference. Combined active therapies showed the biggest improvement on CGI-I score, followed by CBT alone. All active treatments had better than expected HAMD percentage reduction and CGI-I scores. CBT has a clinically relevant effect in depression, with a notional CGI-I score of 2.2, indicating a significant clinical response. The non-specific or placebo effect of being in a psychotherapy trial was a 29% reduction of HAMD. Copyright © 2017. Published by Elsevier Masson SAS.

  10. Exposure to low dose ionising radiation: Molecular and clinical consequences.

    LENUS (Irish Health Repository)

    Martin, Lynn M

    2014-07-10

    This review article provides a comprehensive overview of the experimental data detailing the incidence, mechanism and significance of low dose hyper-radiosensitivity (HRS). Important discoveries gained from past and present studies are mapped and highlighted to illustrate the pathway to our current understanding of HRS and the impact of HRS on the cellular response to radiation in mammalian cells. Particular attention is paid to the balance of evidence suggesting a role for DNA repair processes in the response, evidence suggesting a role for the cell cycle checkpoint processes, and evidence investigating the clinical implications\\/relevance of the effect.

  11. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    Science.gov (United States)

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  12. A conscious mouse model of gastric ileus using clinically relevant endpoints

    Directory of Open Access Journals (Sweden)

    Shao Yuanlin

    2005-06-01

    Full Text Available Abstract Background Gastric ileus is an unsolved clinical problem and current treatment is limited to supportive measures. Models of ileus using anesthetized animals, muscle strips or isolated smooth muscle cells do not adequately reproduce the clinical situation. Thus, previous studies using these techniques have not led to a clear understanding of the pathophysiology of ileus. The feasibility of using food intake and fecal output as simple, clinically relevant endpoints for monitoring ileus in a conscious mouse model was evaluated by assessing the severity and time course of various insults known to cause ileus. Methods Delayed food intake and fecal output associated with ileus was monitored after intraperitoneal injection of endotoxin, laparotomy with bowel manipulation, thermal injury or cerulein induced acute pancreatitis. The correlation of decreased food intake after endotoxin injection with gastric ileus was validated by measuring gastric emptying. The effect of endotoxin on general activity level and feeding behavior was also determined. Small bowel transit was measured using a phenol red marker. Results Each insult resulted in a transient and comparable decrease in food intake and fecal output consistent with the clinical picture of ileus. The endpoints were highly sensitive to small changes in low doses of endotoxin, the extent of bowel manipulation, and cerulein dose. The delay in food intake directly correlated with delayed gastric emptying. Changes in general activity and feeding behavior were insufficient to explain decreased food intake. Intestinal transit remained unchanged at the times measured. Conclusion Food intake and fecal output are sensitive markers of gastric dysfunction in four experimental models of ileus. In the mouse, delayed gastric emptying appears to be the major cause of the anorexic effect associated with ileus. Gastric dysfunction is more important than small bowel dysfunction in this model. Recovery of

  13. Clinical relevance of metronidazole and peripheral neuropathy: a systematic review of the literature.

    Science.gov (United States)

    Goolsby, Tiffany A; Jakeman, Bernadette; Gaynes, Robert P

    2018-03-01

    The objective of this paper was to review and evaluate the literature on metronidazole-associated peripheral neuropathy and determine the relevance in clinical practice. MEDLINE/PubMed, EBSCO, and Google Scholar were searched through February 2017 using the search terms metronidazole and peripheral neuropathy, or polyneuropathy, or paresthesia, or neurotoxicity. Relevant case reports, retrospective studies, surveys, and review articles were included. Bibliographies of all relevant articles were reviewed for additional sources. Overall, metronidazole is generally well tolerated, but serious neurotoxicity, including peripheral neuropathy, has been reported. The overall incidence of peripheral neuropathy associated with metronidazole is unknown. Our review found 36 case reports (40 unique patients) of metronidazole-associated peripheral neuropathy, with most cases (31/40) receiving a >42 g total (>4 weeks) of therapy. In addition, we reviewed 13 clinical studies and found varying rates of peripheral neuropathy from 0 to 50%. Within these clinical studies, we found a higher incidence of peripheral neuropathy in patients receiving >42 g total (>4 weeks) of metronidazole compared with those patients receiving ≤42 g total (17.9% vs. 1.7%). Nearly all patients had complete resolution of symptoms. In conclusion, peripheral neuropathy is rare in patients who receive ≤42 g total of metronidazole. Patients who receive higher total doses may be at higher risk of peripheral neuropathy, but symptoms resolve after discontinuation of therapy in most patients. Antimicrobial stewardship programs may consider use of antibiotic combinations that include metronidazole over broad-spectrum alternatives when treating with ≤42 g total of the drug (≤4 weeks). Published by Elsevier B.V.

  14. Effect of cisplatin on the clinically relevant radiosensitivity of human cervical carcinoma cell lines

    International Nuclear Information System (INIS)

    Britten, Richard A.; Evans, Andrew J.; Allalunis-Turner, M. Joan; Pearcey, Robert G.

    1996-01-01

    Purpose: To evaluate the effect of clinically relevant levels of cisplatin on the radiosensitivity of human cervical tumor cells, and to estimate what changes in local control rates might be expected to accrue from the concomitant use of cisplatin during fractionated radiotherapy. Methods and Materials: The effects of concomitant cisplatin (1 μg/ml, a typical intratumor concentration) on the clinically relevant radiosensitivity, i.e., surviving fraction after 2 G (SF 2 ) values, was determined in 19 cloned human cervical tumor cell lines. These early passage cell lines had SF 2 values ranging from 0.26 to 0.87. Results: The concomitant administration of cisplatin reduced the clinically relevant radiosensitivity in the majority (11 out of 19) of the human tumor cell lines investigated. In only 4 out of 19 was any radiosensitization observed, and in 4 out of 19 cell lines there was no significant change in radiosensitivity. However, the sum of the independent cell killing by radiation and cisplatin, was approximately twofold higher than after radiation alone. There was no apparent dependence of the cisplatin-induced changes in SF 2 values upon the level of cell killing by cisplatin. However, there is a suggestion that concomitant cisplatin administration may have a differential effect in inherently radiosensitive and resistant human tumor cell lines. Conclusions: Our data suggest that concomitant cisplatin/radiotherapy regimens may result in a higher level of local tumor control, but primarily through additive toxicity and not through radiosensitization. Future improvements in local tumor control may, thus, be derived by increasing the total dose of cisplatin

  15. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  16. Evaluation of dose reduction versus standard dosing for maintenance of remission in patients with spondyloarthritis and clinical remission with anti-TNF (REDES-TNF): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Pontes, Caridad; Gratacós, Jordi; Torres, Ferran; Avendaño, Cristina; Sanz, Jesús; Vallano, Antoni; Juanola, Xavier; de Miguel, Eugenio; Sanmartí, Raimon; Calvo, Gonzalo

    2015-08-20

    Dose reduction schedules of tumor necrosis factor antagonists (anti-TNF) as maintenance therapy in patients with spondyloarthritis are used empirically in clinical practice, despite the lack of clinical trials providing evidence for this practice. To address this issue the Spanish Society of Rheumatology (SER) and Spanish Society of Clinical Pharmacology (SEFC) designed a 3-year multicenter, randomized, open-label, controlled clinical trial (2 years for inclusion and 1 year of follow-up). The study is expected to include 190 patients with axial spondyloarthritis on stable maintenance treatment (≥4 months) with any anti-TNF agent at doses recommended in the summary of product characteristics. Patients will be randomized to either a dose reduction arm or maintenance of the dosing regimen as per the official labelling recommendations. Randomization will be stratified according to the anti-TNF agent received before study inclusion. Patient follow-up, visit schedule, and examinations will be maintained as per normal clinical practice recommendations according to SER guidelines. The study aims to test the hypothesis of noninferiority of the dose reduction strategy compared with standard treatment. The first patients were recruited in July 2012, and study completion is scheduled for the end of April 2015. The REDES-TNF study is a pragmatic clinical trial that aims to provide evidence to support a medical decision now made empirically. The study results may help inform clinical decisions relevant to both patients and healthcare decision makers. EudraCT 2011-005871-18 (21 December 2011).

  17. Interaction of platinum drugs with clinically relevant x-ray doses in mammalian cells: A comparison of cisplatin, carboplatin, iproplatin, and tetraplatin

    International Nuclear Information System (INIS)

    Skov, K.; MacPhail, S.

    1991-01-01

    Whereas the interaction between radiation and platinum complexes has never been pronounced in radiobiological experiments (to 30 Gy in mammalian cells), there have been reports of interest in this combination in the clinic, where fractionated doses of approximately 2 Gy are used. Our studies on the marked interaction in hypoxia at the 80% survival level (1-2.5 Gy) with cisplatin have been extended to second generation platinum drugs of clinical interest. The studies in the lower radiation dose region have been facilitated by the use of the cell analyzer DMIPS to identify individual cells and follow them microscopically to assess for clonogenic ability. Chinese hamster V79 cells were used, which were exposed to drug for 1 hr prior to irradiation in hypoxia (or air). None of the drugs give an enhancement ratio (ER) greater than 1.3 in the high radiation dose region, whereas all can produce ER80% (ER calculated at iso-survival of 80%) of 2 or higher at low doses in hypoxic cells. The enhancement of radiation kill in oxic V79 cells (ER's to 1.1 at 1-2% S) disappears at low doses (ER80% = 1.0) except for tetraplatin, where a moderate ER80% (to 1.64) was measured. Comparison of the hypoxic interaction on a concentration basis suggests that cisplatin is the best drug at low x-ray doses and low concentrations, but the interaction reaches a plateau at ER80% approximately 2.0. Tetraplatin continues to give better interaction with increasing concentration (up to ER80% = 3.7 at 25 microM). Interaction of radiation with the less toxic drugs, iproplatin and carboplatin, used at around 100 microM can be improved by longer exposure times prior to irradiation. Comparison on the basis of toxicity, for which the plating efficiency was used, suggests that cisplatin gives a better interaction than the three newer drugs for a given level of toxicity in hypoxic V79 cells

  18. Radiation doses to personnel in clinics for gynecologic oncology

    International Nuclear Information System (INIS)

    Forsberg, B.; Spanne, P.

    1985-01-01

    Radium or Cesium is used for radiotherapy of gynecologic cancer at six clinics in Sweden. This report gives a survey of the radiation doses the personnel is exposed to. The measurement were performed using TL-dosimeters. The dose equivalents for different parts of the body at specific working moments was deduced as well as the effective dose equivalent and the collective dose equivalent. 1983 the total collective dose equivalent for the six clinics was 1.3 manSv, which corresponds to 3.9 manmSv/g equivalent mass of Radium used at the treatments. (With 11 tables and 10 figures) (L.E.)

  19. Clinical relevance of pharmacist intervention in an emergency department.

    Science.gov (United States)

    Pérez-Moreno, Maria Antonia; Rodríguez-Camacho, Juan Manuel; Calderón-Hernanz, Beatriz; Comas-Díaz, Bernardino; Tarradas-Torras, Jordi

    2017-08-01

    To evaluate the clinical relevance of pharmacist intervention on patient care in emergencies, to determine the severity of detected errors. Second, to analyse the most frequent types of interventions and type of drugs involved and to evaluate the clinical pharmacist's activity. A 6-month observational prospective study of pharmacist intervention in the Emergency Department (ED) at a 400-bed hospital in Spain was performed to record interventions carried out by the clinical pharmacists. We determined whether the intervention occurred in the process of medication reconciliation or another activity, and whether the drug involved belonged to the High-Alert Medications Institute for Safe Medication Practices (ISMP) list. To evaluate the severity of the errors detected and clinical relevance of the pharmacist intervention, a modified assessment scale of Overhage and Lukes was used. Relationship between clinical relevance of pharmacist intervention and the severity of medication errors was assessed using ORs and Spearman's correlation coefficient. During the observation period, pharmacists reviewed the pharmacotherapy history and medication orders of 2984 patients. A total of 991 interventions were recorded in 557 patients; 67.2% of the errors were detected during medication reconciliation. Medication errors were considered severe in 57.2% of cases and 64.9% of pharmacist intervention were considered relevant. About 10.9% of the drugs involved are in the High-Alert Medications ISMP list. The severity of the medication error and the clinical significance of the pharmacist intervention were correlated (Spearman's ρ=0.728/pclinical pharmacists identified and intervened on a high number of severe medication errors. This suggests that emergency services will benefit from pharmacist-provided drug therapy services. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Saturated norepinephrine transporter occupancy by atomoxetine relevant to clinical doses: a rhesus monkey study with (S,S)-[18F]FMeNER-D2

    International Nuclear Information System (INIS)

    Takano, Akihiro; Gulyas, Balazs; Varrone, Andrea; Halldin, Christer; Maguire, Ralph Paul

    2009-01-01

    In a previous PET study on norepinephrine transporter (NET) occupancy in the nonhuman primate brain, the relationship between NET occupancy and atomoxetine plasma concentration, and occupancies among different brain regions, were not demonstrated adequately. It may therefore be difficult to translate the results to the clinical situations. In the present study, the detailed change of NET occupancy was investigated among a wider range of doses in a more advanced manner. Two rhesus monkeys were examined using a high-resolution PET system with (S,S)-[ 18 F]FMeNER-D 2 under baseline conditions and after steady-state infusion of different doses of atomoxetine (0.003 to 0.12 mg/kg per hour). NET occupancy of the thalamus, brainstem and anterior cingulate cortex was calculated using BP ND obtained with the simplified reference tissue model. NET occupancy increased regionally and uniformly as the plasma concentration of atomoxetine increased. The estimated Kd value (the amount to occupy 50% of NET) in the thalamus was 16 ng/ml. The results indicate that clinical doses of atomoxetine would occupy NET almost completely. (orig.)

  1. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  2. TU-H-CAMPUS-TeP3-04: Probing the Dose Enhancement Due to a Clinically-Relevant Concentration of Gold Nanoparticles and Yb-169 Gamma Rays Using PRESAGE Dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J [UT MD Anderson Cancer Center, Houston, TX (United States); Oklahoma State University, Stillwater, OK (United States); Alqathami, M; Cho, S [UT MD Anderson Cancer Center, Houston, TX (United States); Reynoso, F [UT MD Anderson Cancer Center, Houston, TX (United States); Washington University School of Medicine, St. Louis, MO (United States)

    2016-06-15

    Purpose: To probe physical evidences of the dose enhancement due to a low/clinically-relevant concentration of gold nanoparticles (GNPs) and Yb-169 gamma rays using PRESAGE dosimeters. Methods: A PRESAGE cuvette was placed at approximately 2 mm above the plane containing three novel Yb-169 brachytherapy seeds (3.2, 3.2, and 5.3 mCi each). Two types of PRESAGE dosimeters were used – plain PRESAGEs (controls) and PRESAGEs loaded with 0.02 wt. % of GNPs (GNP-PRESAGEs). Each PRESAGE dosimeter was irradiated with different time durations (0 to 24 hours) to deliver 0, 4, 8, 16 and 24 Gy of dose. For a reference/comparison, both types of PRESAGEs were also irradiated using 250 kVp x-rays with/without Er-filter to deliver 0, 3, 10, and 30 Gy of dose. Er-filter was used to emulate Yb-169 spectrum using 250 kVp x-rays. The absorption spectra of PRESAGEs were measured using a UV spectrophotometer and used to determine the corresponding optical densities (ODs). Results: GNP-PRESAGEs exposed to Yb-169 sources showed ∼65% increase in ODs compared with controls. When exposed to Er-filtered and unfiltered 250 kVp x-rays, they produced smaller increases in ODs, ∼41% and ∼37%, respectively. There was a linear relationship between ODs and delivered doses with a goodness-of-fit (R2) greater than 0.99. Conclusion: A notable increase in the ODs (∼65%) was observed for GNP-PRESAGEs irradiated by Yb-169 gamma rays. Considering the observed OD increases, it was highly likely that Yb-169 gamma rays were more effective than both Er-filtered and unfiltered 250 kVp x-rays, in terms of producing the dose enhancement. Due to several unknown factors (e.g., possible difference in the dose response of GNP-PRESAGEs vs. PRESAGEs), however, a further investigations is necessary to establish the feasibility of quantifying the exact amount of macroscopic or microscopic/local GNP-mediated dose enhancement using PRESAGE or similar volumetric dosimeters. Supported by DOD/PCRP grant W81XWH-12

  3. Blocking Avoidance and Escape Responses: Relations With Clinically Relevant Behaviors

    Directory of Open Access Journals (Sweden)

    Juliana Maria Bubna Popovitz

    Full Text Available Abstract: The current study aims to evaluate the possible effects of interrupting problematic clinically relevant behaviors on the percentage of these responses and of clinical improvement-related responses. Two clients were treated with Functional Analytic Psychotherapy (FAP, alternating two conditions (ABAB. On condition A, procedures to the therapist consisted of responding to the clinical improvement responses, and to description of outside of therapeutic setting behaviors, but therapists were advised to ignore problem behaviors emitted in session. During condition B, therapists followed the same procedures, but they were oriented to block (interrupt problematic responses emitted in session. Results suggest increase in the percentage of problem behaviors during condition B. Results are discussed, highlighting the viability of planning the contingent response the therapist emits to clinically relevant behaviors.

  4. What is the clinically relevant change on the ADAS-Cog?

    Science.gov (United States)

    Schrag, Anette; Schott, Jonathan M

    2012-02-01

    To establish the minimal clinically relevant change (MCRC) on the Alzheimer's Disease Assessment Scale-Cognitive (ADAS-Cog) for patients with mild Alzheimer's disease (AD). Cohort study. 59 recruiting sites for the Alzheimer's Disease Neuroimaging Initiative. Outpatients with AD in the Alzheimer's Disease Neuroimaging Initiative. The authors applied anchor-based MCRC methodology comparing ADAS-Cog change against clinicians' judgement of clinically relevant worsening between baseline and 6 months in four domains: memory and non-memory cognitive performance; Clinical Dementia Rating Scale; and Functional Assessment Questionnaire. The analysis was repeated for the 6-12-month interval. To support these findings, the authors calculated distribution-based measures including half-baseline SD (1/2 SD) and SEM. 181 patients (baseline ADAS-Cog score 18.5±6.4) had ADAS-Cog data at 0 and 6 months. Those undergoing clinically significant worsening on any of the four anchor questions (n=41-47) had an average ADAS-Cog change of 3.1-3.8 points. Similar results were found for the 177 patients with 6-12-month data. The average 1/2 SD for the baseline ADAS-Cog score was 3.2, and the SEM was 3.7. 3 points decline on the ADAS-Cog may be an appropriate MCRC for clinical trials of patients with early AD. However, further studies assessing the MCRC for improvement on the ADAS-Cog, using patient-based judgement as an anchor, and determining the minimal clinically relevant difference between change on two treatments are required. http://clinicalTrials.gov Identifier: NCT00106899.

  5. Searching for Clinically Relevant Biomarkers in Geriatric Oncology.

    Science.gov (United States)

    Katsila, Theodora; Patrinos, George P; Kardamakis, Dimitrios

    2018-01-01

    Ageing, which is associated with a progressive decline and functional deterioration in multiple organ systems, is highly heterogeneous, both inter- and intraindividually. For this, tailored-made theranostics and optimum patient stratification become fundamental, when decision-making in elderly patients is considered. In particular, when cancer incidence and cancer-related mortality and morbidity are taken into account, elderly patient care is a public health concern. In this review, we focus on oncogeriatrics and highlight current opportunities and challenges with an emphasis on the unmet need of clinically relevant biomarkers in elderly cancer patients. We performed a literature search on PubMed and Scopus databases for articles published in English between 2000 and 2017 coupled to text mining and analysis. Considering the top insights, we derived from our literature analysis that information knowledge needs to turn into knowledge growth in oncogeriatrics towards clinically relevant biomarkers, cost-effective practices, updated educational schemes for health professionals (in particular, geriatricians and oncologists), and awareness of ethical issues. We conclude with an interdisciplinary call to omics, geriatricians, oncologists, informatics, and policy-makers communities that Big Data should be translated into decision-making in the clinic.

  6. Clinically relevant potential drug-drug interactions among outpatients: A nationwide database study.

    Science.gov (United States)

    Jazbar, Janja; Locatelli, Igor; Horvat, Nejc; Kos, Mitja

    2018-06-01

    Adverse drug events due to drug-drug interactions (DDIs) represent a considerable public health burden, also in Slovenia. A better understanding of the most frequently occurring potential DDIs may enable safer pharmacotherapy and minimize drug-related problems. The aim of this study was to evaluate the prevalence and predictors of potential DDIs among outpatients in Slovenia. An analysis of potential DDIs was performed using health claims data on prescription drugs from a nationwide database. The Lexi-Interact Module was used as the reference source of interactions. The influence of patient-specific predictors on the risk of potential clinically relevant DDIs was evaluated using logistic regression model. The study population included 1,179,803 outpatients who received 15,811,979 prescriptions. The total number of potential DDI cases identified was 3,974,994, of which 15.6% were potentially clinically relevant. Altogether, 9.3% (N = 191,213) of the total population in Slovenia is exposed to clinically relevant potential DDIs, and the proportion is higher among women and the elderly. After adjustment for cofactors, higher number of medications and older age are associated with higher odds of clinically relevant potential DDIs. The burden of DDIs is highest with drug combinations that increase risk of bleeding, enhance CNS depression or anticholinergic effects or cause cardiovascular complications. The current study revealed that 1 in 10 individuals in the total Slovenian population is exposed to clinically relevant potential DDIs yearly. Taking into account the literature based conservative estimate that approximately 1% of potential DDIs result in negative health outcomes, roughly 1800 individuals in Slovenia experience an adverse health outcome each year as a result of clinically relevant potential interactions alone. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Extent of radiosensitization by the PARP inhibitor olaparib depends on its dose, the radiation dose and the integrity of the homologous recombination pathway of tumor cells

    NARCIS (Netherlands)

    Verhagen, Caroline V. M.; de Haan, Rosemarie; Hageman, Floor; Oostendorp, Tim P. D.; Carli, Annalisa L. E.; O'Connor, Mark J.; Jonkers, Jos; Verheij, Marcel; van den Brekel, Michiel W.; Vens, Conchita

    2015-01-01

    The PARP inhibitor olaparib is currently tested in clinical phase 1 trials to define safe dose levels in combination with RT. However, certain clinically relevant insights are still lacking. Here we test, while comparing to single agent activity, the olaparib dose and genetic background dependence

  8. Isoeffective dose: a concept for biological weighting of absorbed dose in proton and heavier-ion therapies

    CERN Document Server

    Wambersie, A; Menzel, H G; Gahbauer, R; DeLuca, P M; Hendry, J H; Jones, D T L

    2011-01-01

    When reporting radiation therapy procedures, International Commission on Radiation Units and Measurements (ICRU) recommends specifying absorbed dose at/in all clinically relevant points and/or volumes. In addition, treatment conditions should be reported as completely as possible in order to allow full understanding and interpretation of the treatment prescription. However, the clinical outcome does not only depend on absorbed dose but also on a number of other factors such as dose per fraction, overall treatment time and radiation quality radiation biology effectiveness (RBE). Therefore, weighting factors have to be applied when different types of treatments are to be compared or to be combined. This had led to the concept of `isoeffective absorbed dose', introduced by ICRU and International Atomic Energy Agency (IAEA). The isoeffective dose D(IsoE) is the dose of a treatment carried out under reference conditions producing the same clinical effects on the target volume as those of the actual treatment. It i...

  9. Clinical Effectiveness and Dose Titration in Pediatric Practice

    Directory of Open Access Journals (Sweden)

    Yu.V. Marushko

    2016-02-01

    Full Text Available The paper is devoted to the questions of usage of one of the popular antipyretic and anesthetic drug in pediatric practice — ibuprofen. In the article there are generalized literature data and own experience in ibuprofen dose titration in single dose 5 and 10 mg/kg depending on clinical situation.

  10. A clinical comparison of high dose and low dose of Suxamethonium

    Directory of Open Access Journals (Sweden)

    RK Yadav

    2014-01-01

    Full Text Available Background: Suxamethonium having its rapid onset and short duration of action makes this drug unique amongst the neuromuscular blocking drugs described so far. However, use of suxamethonium is associated with a large number of undesirable side effects. Objective: To evaluate clinical effects of high and low dose of suxamethonium and to determine whether lower dose of suxamethonium can be used for any beneficial effects in terms of its various adverse effects e.g. cardiovascular responses, post-operative muscle pains and intraocular pressure. Methods: A total of 100 patients were included in this prospective study. All these patients on preoperative clinical evaluation were assessed to have adequate airway. All the patients were divided in two groups, low dose group (group I and High dose group (group II with 50 patients in each at random. A standard anesthetic technique was adhered to all the patients and following parameters were observed on comparative basis: a. Fasciculation and post operative myalgia. b. Cardiovascular effects, c. Intraocular pressure. Observation: The incidence of post Suxamethonium pain was significantly greater in group II. Increase in heart rate from baseline was significant in both groups. There was no significant difference between the two groups in the diastolic pressure but rise in systolic blood pressure was significant at all assessment times in both groups. This rise from control was statistically significant. Conclusion: Suxamethonium can be used in lower doses (0.5 mg/kg in elective cases without airway compromise. It gives benefits of reduced muscle pains, cardiovascular responses and intraocular hypertension. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 1-8 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9677

  11. In search of the relevant lung dose

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1982-12-01

    Researchers have traditionally been inconsistent in their methods of determining and reporting dose to the lung from inhaled radionuclides - a situation which has led to difficulties in later comparing results and deriving dose-response relationships. The dose quantities which at present are most generally assumed to be related to risk of stochastic radiation effects (such as lung cancer) are (1) mean dose equivalent to the bronchial epithelium basal cell layer for radon daughters, and (2) mean dose equivalent to the whole lung (including tracheobronchial lymph nodes) for all other radionuclides. The average radiation dose is calculated by assuming that the energy is homogeneously impared to the entire tissue mass. However, the actual dose received by a cell which becomes transformed or tumorigenic is likely to be very much different than the smear dose to the entire organ. This realization has led to further study of stochastic energy deposition processes in single cells or cell nuclei from internal emitters. The end product of the stochastic approach to dosimetry, sometimes called microdosimetry, is a probability density in specific energy. For alpha-emitting radionuclides in the lung, a concept that may be more important than dose is the probability that a cell is hit by an alpha particle

  12. Extent of radiosensitization by the PARP inhibitor olaparib depends on its dose, the radiation dose and the integrity of the homologous recombination pathway of tumor cells

    NARCIS (Netherlands)

    Verhagen, C.V.M.; Haan, R. den; Hageman, F.; Oostendorp, T.P.; Carli, A.L.; O'Connor, M.J.; Jonkers, J.; Verheij, M.; Brekel, M.W. van den; Vens, C.

    2015-01-01

    BACKGROUND AND PURPOSE: The PARP inhibitor olaparib is currently tested in clinical phase 1 trials to define safe dose levels in combination with RT. However, certain clinically relevant insights are still lacking. Here we test, while comparing to single agent activity, the olaparib dose and genetic

  13. Extent of radiosensitization by the PARP inhibitor olaparib depends on its dose, the radiation dose and the integrity of the homologous recombination pathway of tumor cells

    NARCIS (Netherlands)

    Verhagen, C.V.M.; de Haan, R.; Hageman, F.; Oostendorp, T.P.D.; Carli, A.L.E.; O'Connor, M.J.; Jonkers, J.; Verheij, M.; van den Brekel, M.W.; Vens, C.

    2015-01-01

    Background and purpose The PARP inhibitor olaparib is currently tested in clinical phase 1 trials to define safe dose levels in combination with RT. However, certain clinically relevant insights are still lacking. Here we test, while comparing to single agent activity, the olaparib dose and genetic

  14. Clinical implementation and evaluation of the Acuros dose calculation algorithm.

    Science.gov (United States)

    Yan, Chenyu; Combine, Anthony G; Bednarz, Greg; Lalonde, Ronald J; Hu, Bin; Dickens, Kathy; Wynn, Raymond; Pavord, Daniel C; Saiful Huq, M

    2017-09-01

    The main aim of this study is to validate the Acuros XB dose calculation algorithm for a Varian Clinac iX linac in our clinics, and subsequently compare it with the wildely used AAA algorithm. The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were validated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6 cm × 6 cm to 40 cm × 40 cm. Central axis and off-axis points with different depths were chosen for the comparison. In addition, the accuracy of Acuros was evaluated for wedge fields with wedge angles from 15 to 60°. Similarly, variable field sizes for an inhomogeneous phantom were chosen to validate the Acuros algorithm. In addition, doses calculated by Acuros and AAA at the center of lung equivalent tissue from three different VMAT plans were compared to the ion chamber measured doses in QUASAR phantom, and the calculated dose distributions by the two algorithms and their differences on patients were compared. Computation time on VMAT plans was also evaluated for Acuros and AAA. Differences between dose-to-water (calculated by AAA and Acuros XB) and dose-to-medium (calculated by Acuros XB) on patient plans were compared and evaluated. For open 6 MV photon beams on the homogeneous water phantom, both Acuros XB and AAA calculations were within 1% of measurements. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. Testing on the inhomogeneous phantom demonstrated that AAA overestimated doses by up to 8.96% at a point close to lung/solid water interface, while Acuros XB reduced that to 1.64%. The test on QUASAR phantom showed that Acuros achieved better agreement in lung equivalent tissue while AAA underestimated dose for all VMAT plans by up to 2.7%. Acuros XB computation time was about three times faster than AAA for VMAT plans, and

  15. Application of organ tolerance dose-constraints in clinical studies in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, Wolfgang [Medical University/AKH Vienna, Dept. of Radiation Oncology/Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Comprehensive Cancer Center, Vienna (Austria); Technical University Dresden, Department of Radiotherapy and Radiation Oncology, OncoRay-National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, Dresden (Germany); Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany); Herrmann, Thomas [Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany); Baumann, Michael [Technical University Dresden, Department of Radiotherapy and Radiation Oncology, OncoRay-National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, Dresden (Germany); Task Group ' ' Tolerance Doses' ' of the German Society for Radiation Oncology (DEGRO), Berlin (Germany)

    2014-07-15

    In modern radiation oncology, tolerance dose-constraints for organs at risk (OAR) must be considered for treatment planning, but particularly in order to design clinical studies. Tolerance dose tables, however, only address one aspect of the therapeutic ratio of any clinical study, i.e., the limitation of adverse events, but not the desired potential improvement in the tumor effect of a novel treatment strategy. A sensible application of ''tolerance doses'' in a clinical situation requires consideration of various critical aspects addressed here: definition of tolerance dose, specification of an endpoint/symptom, consideration of radiation quality and irradiation protocol, exposed volume and dose distribution, and patient-related factors of radiosensitivity. The currently most comprehensive estimates of OAR radiation tolerance are in the QUANTEC compilations (2010). However, these tolerance dose values must only be regarded as a rough orientation and cannot answer the relevant question for the patients, i.e., if the study can achieve a therapeutic advantage; this can obviously be answered only by the final scientific analysis of the study results. Despite all limitations, the design of clinical studies should currently refer to the QUANTEC values for appreciation of the risk of complications, if needed supplemented by one's own data or further information from the literature. The implementation of a consensus on the safety interests of the patients and on an application and approval process committed to progress in medicine, with transparent quality-assuring requirements with regard to the structural safeguarding of the study activities, plays a central role in clinical research in radiation oncology. (orig.) [German] In der modernen Radioonkologie muessen Toleranzdosisgrenzen fuer die Risikoorgane (''organs at risk'', OAR) zur Behandlungsplanung, besonders aber zur Gestaltung klinischer Studien, herangezogen werden

  16. Using mixed methods to identify and answer clinically relevant research questions.

    Science.gov (United States)

    Shneerson, Catherine L; Gale, Nicola K

    2015-06-01

    The need for mixed methods research in answering health care questions is becoming increasingly recognized because of the complexity of factors that affect health outcomes. In this article, we argue for the value of using a qualitatively driven mixed method approach for identifying and answering clinically relevant research questions. This argument is illustrated by findings from a study on the self-management practices of cancer survivors and the exploration of one particular clinically relevant finding about higher uptake of self-management in cancer survivors who had received chemotherapy treatment compared with those who have not. A cross-sectional study generated findings that formed the basis for the qualitative study, by informing the purposive sampling strategy and generating new qualitative research questions. Using a quantitative research component to supplement a qualitative study can enhance the generalizability and clinical relevance of the findings and produce detailed, contextualized, and rich answers to research questions that would be unachievable through quantitative or qualitative methods alone. © The Author(s) 2015.

  17. Classification of first branchial cleft anomalies: is it clinically relevant ...

    African Journals Online (AJOL)

    Background: There are three classification systems for first branchial cleft anomalies currently in use. The Arnot, Work and Olsen classifications describe these lesions on the basis of morphology, tissue of origin and clinical appearance. However, the clinical relevance of these classifications is debated, as they may not be ...

  18. The clinical relevance and newsworthiness of NIHR HTA-funded research: a cohort study.

    Science.gov (United States)

    Wright, D; Young, A; Iserman, E; Maeso, R; Turner, S; Haynes, R B; Milne, R

    2014-05-07

    To assess the clinical relevance and newsworthiness of the UK National Institute for Health Research (NIHR) Health Technology Assessment (HTA) Programme funded reports. Retrospective cohort study. The cohort included 311 NIHR HTA Programme funded reports publishing in HTA in the period 1 January 2007-31 December 2012. The McMaster Online Rating of Evidence (MORE) system independently identified the clinical relevance and newsworthiness of NIHR HTA publications and non-NIHR HTA publications. The MORE system involves over 4000 physicians rating publications on a scale of relevance (the extent to which articles are relevant to practice) and a scale of newsworthiness (the extent to which articles contain news or something clinicians are unlikely to know). The proportion of reports published in HTA meeting MORE inclusion criteria and mean average relevance and newsworthiness ratings were calculated and compared with publications from the same studies publishing outside HTA and non-NIHR HTA funded publications. 286/311 (92.0%) of NIHR HTA reports were assessed by MORE, of which 192 (67.1%) passed MORE criteria. The average clinical relevance rating for NIHR HTA reports was 5.48, statistically higher than the 5.32 rating for non-NIHR HTA publications (mean difference=0.16, 95% CI 0.04 to 0.29, p=0.01). Average newsworthiness ratings were similar between NIHR HTA reports and non-NIHR HTA publications (4.75 and 4.70, respectively; mean difference=0.05, 95% CI -0.18 to 0.07, p=0.402). NIHR HTA-funded original research reports were statistically higher for newsworthiness than reviews (5.05 compared with 4.64) (mean difference=0.41, 95% CI 0.18 to 0.64, p=0.001). Funding research of clinical relevance is important in maximising the value of research investment. The NIHR HTA Programme is successful in funding projects that generate outputs of clinical relevance.

  19. Saturated norepinephrine transporter occupancy by atomoxetine relevant to clinical doses: a rhesus monkey study with (S,S)-[{sup 18}F]FMeNER-D{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Akihiro; Gulyas, Balazs; Varrone, Andrea; Halldin, Christer [Karolinska Institutet, Department of Clinical Neuroscience, Psychiatry Section, Stockholm (Sweden); Maguire, Ralph Paul [Pfizer Global Research and Development, New London, CT (United States); Novartis Institutes for BioMedical Research, Basel (Switzerland)

    2009-08-15

    In a previous PET study on norepinephrine transporter (NET) occupancy in the nonhuman primate brain, the relationship between NET occupancy and atomoxetine plasma concentration, and occupancies among different brain regions, were not demonstrated adequately. It may therefore be difficult to translate the results to the clinical situations. In the present study, the detailed change of NET occupancy was investigated among a wider range of doses in a more advanced manner. Two rhesus monkeys were examined using a high-resolution PET system with (S,S)-[{sup 18}F]FMeNER-D{sub 2} under baseline conditions and after steady-state infusion of different doses of atomoxetine (0.003 to 0.12 mg/kg per hour). NET occupancy of the thalamus, brainstem and anterior cingulate cortex was calculated using BP{sub ND} obtained with the simplified reference tissue model. NET occupancy increased regionally and uniformly as the plasma concentration of atomoxetine increased. The estimated Kd value (the amount to occupy 50% of NET) in the thalamus was 16 ng/ml. The results indicate that clinical doses of atomoxetine would occupy NET almost completely. (orig.)

  20. Precision Oncology Medicine: The Clinical Relevance of Patient-Specific Biomarkers Used to Optimize Cancer Treatment.

    Science.gov (United States)

    Schmidt, Keith T; Chau, Cindy H; Price, Douglas K; Figg, William D

    2016-12-01

    Precision medicine in oncology is the result of an increasing awareness of patient-specific clinical features coupled with the development of genomic-based diagnostics and targeted therapeutics. Companion diagnostics designed for specific drug-target pairs were the first to widely utilize clinically applicable tumor biomarkers (eg, HER2, EGFR), directing treatment for patients whose tumors exhibit a mutation susceptible to an FDA-approved targeted therapy (eg, trastuzumab, erlotinib). Clinically relevant germline mutations in drug-metabolizing enzymes and transporters (eg, TPMT, DPYD) have been shown to impact drug response, providing a rationale for individualized dosing to optimize treatment. The use of multigene expression-based assays to analyze an array of prognostic biomarkers has been shown to help direct treatment decisions, especially in breast cancer (eg, Oncotype DX). More recently, the use of next-generation sequencing to detect many potential "actionable" cancer molecular alterations is further shifting the 1 gene-1 drug paradigm toward a more comprehensive, multigene approach. Currently, many clinical trials (eg, NCI-MATCH, NCI-MPACT) are assessing novel diagnostic tools with a combination of different targeted therapeutics while also examining tumor biomarkers that were previously unexplored in a variety of cancer histologies. Results from ongoing trials such as the NCI-MATCH will help determine the clinical utility and future development of the precision-medicine approach. © 2016, The American College of Clinical Pharmacology.

  1. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  2. SU-F-T-345: Quasi-Dead Beams: Clinical Relevance and Implications for Automatic Planning

    Energy Technology Data Exchange (ETDEWEB)

    Price, R; Veltchev, I; Lin, T; Gleason, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Beam direction selection for fixed-beam IMRT planning is typically a manual process. Severe dose-volume limits on critical structures in the thorax often result in atypical selection of beam directions as compared to other body sites. This work demonstrates the potential consequences as well as clinical relevance. Methods: 21 thoracic cases treated with 5–7 beam directions, 6 cases including non-coplanar arrangements, with fractional doses of 150–411cGy were analyzed. Endpoints included per-beam modulation scaling factor (MSF), variation from equal weighting, and delivery QA passing rate. Results: During analysis of patient-specific delivery QA a sub-standard passing rate was found for a single 5-field plan (90.48% of pixels evaluated passing 3% dose, 3mm DTA). During investigation it was found that a single beam demonstrated a MSF of 34.7 and contributed only 2.7% to the mean dose of the target. In addition, the variation from equal weighting for this beam was 17.3% absolute resulting in another beam with a MSF of 4.6 contributing 41.9% to the mean dose to the target; a variation of 21.9% from equal weighting. The average MSF for the remaining 20 cases was 4.0 (SD 1.8) with an average absolute deviation of 2.8% from equal weighting (SD 3.1%). Conclusion: Optimization in commercial treatment planning systems typically results in relatively equally weighted beams. Extreme variation from this can result in excessively high MSFs (very small segments) and potential decreases in agreement between planned and delivered dose distributions. In addition, the resultant beam may contribute minimal dose to the target (quasi-dead beam); a byproduct being increased treatment time and associated localization uncertainties. Potential ramifications exist for automatic planning algorithms should they allow for user-defined beam directions. Additionally, these quasi-dead beams may be embedded in the libraries for model-based systems potentially resulting in inefficient

  3. Dose Escalation Methods in Phase I Cancer Clinical Trials

    OpenAIRE

    Le Tourneau, Christophe; Lee, J. Jack; Siu, Lillian L.

    2009-01-01

    Phase I clinical trials are an essential step in the development of anticancer drugs. The main goal of these studies is to establish the recommended dose and/or schedule of new drugs or drug combinations for phase II trials. The guiding principle for dose escalation in phase I trials is to avoid exposing too many patients to subtherapeutic doses while preserving safety and maintaining rapid accrual. Here we review dose escalation methods for phase I trials, including the rule-based and model-...

  4. Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization

    International Nuclear Information System (INIS)

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-01-01

    Background: CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. Objectives: To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Methods: Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Results: Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (−47%; 95% CI, −44% to −50%), prospective gating (−35%; 95% CI, −29% to −40%) and ECG controlled tube current modulation (−23%; 95% CI, −9% to −34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Conclusion: Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality.

  5. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    Directory of Open Access Journals (Sweden)

    Danbo Yang

    2010-12-01

    Full Text Available The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(L-g-glutamylglutamine-paclitaxel nano-conjugate (PGG-PTX. PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic.

  6. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    International Nuclear Information System (INIS)

    Yang, Danbo; Yu, Lei; Van, Sang

    2010-01-01

    The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(l-γ-glutamylglutamine)-paclitaxel nano-conjugate (PGG-PTX). PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic

  7. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Danbo [Biomedical Engineering and Technology Institute, Institutes for Advanced Interdisciplinary Research, East China Normal University, 3663 North Zhongshan Road, Shanghai, 200062 (China); Yu, Lei, E-mail: yu-lei@gg.nitto.co.jp [Biomedical Engineering and Technology Institute, Institutes for Advanced Interdisciplinary Research, East China Normal University, 3663 North Zhongshan Road, Shanghai, 200062 (China); Biomedical Group, Nitto Denko Technical Corporation, 501 Via Del Monte, Oceanside, CA 92058 (United States); Van, Sang [Biomedical Group, Nitto Denko Technical Corporation, 501 Via Del Monte, Oceanside, CA 92058 (United States)

    2010-12-23

    The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(l-γ-glutamylglutamine)-paclitaxel nano-conjugate (PGG-PTX). PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic.

  8. An inter-hospital comparison of patient dose based on clinical indications

    International Nuclear Information System (INIS)

    Teeuwisse, W.; Geleijns, J.; Veldkamp, W.

    2007-01-01

    Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 μSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals. (orig.)

  9. Normal tissue complication models for clinically relevant acute esophagitis (≥ grade 2) in patients treated with dose differentiated accelerated radiotherapy (DART-bid)

    International Nuclear Information System (INIS)

    Zehentmayr, Franz; Söhn, Matthias; Exeli, Ann-Katrin; Wurstbauer, Karl; Tröller, Almut; Deutschmann, Heinz; Fastner, Gerd; Fussl, Christoph; Steininger, Philipp; Kranzinger, Manfred; Belka, Claus; Studnicka, Michael; Sedlmayer, Felix

    2015-01-01

    One of the primary dose-limiting toxicities during thoracic irradiation is acute esophagitis (AE). The aim of this study is to investigate dosimetric and clinical predictors for AE grade ≥ 2 in patients treated with accelerated radiotherapy for locally advanced non-small cell lung cancer (NSCLC). 66 NSCLC patients were included in the present analysis: 4 stage II, 44 stage IIIA and 18 stage IIIB. All patients received induction chemotherapy followed by dose differentiated accelerated radiotherapy (DART-bid). Depending on size (mean of three perpendicular diameters) tumors were binned in four dose groups: <2.5 cm 73.8 Gy, 2.5–4.5 cm 79.2 Gy, 4.5–6 cm 84.6 Gy, >6 cm 90 Gy. Patients were treated in 3D target splitting technique. In order to estimate the normal tissue complication probability (NTCP), two Lyman models and the cutoff-logistic regression model were fitted to the data with AE ≥ grade 2 as statistical endpoint. Inter-model comparison was performed with the corrected Akaike information criterion (AIC c ), which calculates the model’s quality of fit (likelihood value) in relation to its complexity (i.e. number of variables in the model) corrected by the number of patients in the dataset. Toxicity was documented prospectively according to RTOG. The median follow up was 686 days (range 84–2921 days), 23/66 patients (35 %) experienced AE ≥ grade 2. The actuarial local control rates were 72.6 % and 59.4 % at 2 and 3 years, regional control was 91 % at both time points. The Lyman-MED model (D50 = 32.8 Gy, m = 0.48) and the cutoff dose model (D c = 38 Gy) provide the most efficient fit to the current dataset. On multivariate analysis V38 (volume of the esophagus that receives 38 Gy or above, 95 %-CI 28.2–57.3) was the most significant predictor of AE ≥ grade 2 (HR = 1.05, CI 1.01–1.09, p = 0.007). Following high-dose accelerated radiotherapy the rate of AE ≥ grade 2 is slightly lower than reported for concomitant radio-chemotherapy with the

  10. SU-E-T-135: Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schuemann, J; Giantsoudi, D; Grassberger, C; Paganetti, H [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To estimate the clinical relevance of approximations made in analytical dose calculation methods (ADCs) used for treatment planning on tumor coverage and tumor control probability (TCP) in proton therapy. Methods: We compared dose distributions planned with ADC to delivered dose distributions (as determined by TOPAS Monte Carlo (MC) simulations). We investigated 10 patients per site for 5 treatment sites (head-and-neck, lung, breast, prostate, liver). We evaluated differences between the two dose distributions analyzing dosimetric indices based on the dose-volume-histograms, the γ-index and the TCP. The normal tissue complication probability (NTCP) was estimated for the bladder and anterior rectum for the prostate patients. Results: We find that the target doses are overestimated by the ADC by 1–2% on average for all patients considered. All dosimetric indices (the mean dose, D95, D50 and D02, the dose values covering 95%, 50% and 2% of the target volume, respectively) are predicted within 5% of the delivered dose. A γ-index with a 3%/3mm criteria had a passing rate for target volumes above 96% for all patients. The TCP predicted by the two algorithms was up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head-and-neck and lung patients, respectively. Differences in NTCP for anterior-rectum and bladder for prostate patients were less than 3%. Conclusion: We show that ADC provide adequate dose distributions for most patients, however, they can Result in underdosage of the target by as much as 5%. The TCP was found to be up to 11% lower than predicted. Advanced dose-calculation methods like MC simulations may be necessary in proton therapy to ensure target coverage for heterogeneous patient geometries, in clinical trials comparing proton therapy to conventional radiotherapy to avoid biases due to systematic discrepancies in calculated dose distributions, and, if tighter range margins are considered. Fully funded by NIH grants.

  11. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    Coronary angiography is a procedure used in the diagnosis and intervention of coronary heart disease. The procedure is often considered one of the highest dose diagnostic procedures in clinical use. Despite this, there is minimal use of dosimeters within angiographic catheterisation laboratories due to challenges resulting from their implementation. The aim of this study was to compare entrance dose delivery across locally commissioned c-arms to assess the need for real-time dosimetry solutions during angiographic procedures. The secondary aim of this study was to establish a calibration method for the MOSkin dosimeter that accurately produces entrance dose values from the clinically sampled beam qualities and energies. The MOSkin is a real-time dosimeter used to measure the skin dose delivered by external radiation beams. The suitability of the MOSkin for measurements in the angiographic catheterisation laboratory was assessed. Measurements were performed using a 30 × 30 × 30cm 3 PMMA phantom positioned at the rotational isocenter of the c-arm gantry. The MOSkin calibration factor was established through comparison of the MOSkin response to EBT2 film response. Irradiation of the dosimeters was performed using several clinical beam qualities ranging in energy from 70 to 105 kVp. A total of four different interventional c-arm machines were surveyed and compared using the MOSkin dosimeter. The phantom was irradiated from a normal angle of incidence using clinically relevant protocols, field sizes and source to image detector distance values. The MOSkin was observed to be radiotranslucent to the c-arm beam in all clinical environments. The MOSkin response was reproducible to within 2 % of the average value across repeated measurements for each beam setting. There were large variations in entrance dose delivery to the phantom between the different c-arm machines with the highest observed cine-acquisition entrance dose rate measuring 326 % higher than the lowest

  12. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  13. Postimplant Dosimetry Using a Monte Carlo Dose Calculation Engine: A New Clinical Standard

    International Nuclear Information System (INIS)

    Carrier, Jean-Francois; D'Amours, Michel; Verhaegen, Frank; Reniers, Brigitte; Martin, Andre-Guy; Vigneault, Eric; Beaulieu, Luc

    2007-01-01

    Purpose: To use the Monte Carlo (MC) method as a dose calculation engine for postimplant dosimetry. To compare the results with clinically approved data for a sample of 28 patients. Two effects not taken into account by the clinical calculation, interseed attenuation and tissue composition, are being specifically investigated. Methods and Materials: An automated MC program was developed. The dose distributions were calculated for the target volume and organs at risk (OAR) for 28 patients. Additional MC techniques were developed to focus specifically on the interseed attenuation and tissue effects. Results: For the clinical target volume (CTV) D 90 parameter, the mean difference between the clinical technique and the complete MC method is 10.7 Gy, with cases reaching up to 17 Gy. For all cases, the clinical technique overestimates the deposited dose in the CTV. This overestimation is mainly from a combination of two effects: the interseed attenuation (average, 6.8 Gy) and tissue composition (average, 4.1 Gy). The deposited dose in the OARs is also overestimated in the clinical calculation. Conclusions: The clinical technique systematically overestimates the deposited dose in the prostate and in the OARs. To reduce this systematic inaccuracy, the MC method should be considered in establishing a new standard for clinical postimplant dosimetry and dose-outcome studies in a near future

  14. Pharmacology of dextromethorphan: Relevance to dextromethorphan/quinidine (Nuedexta®) clinical use.

    Science.gov (United States)

    Taylor, Charles P; Traynelis, Stephen F; Siffert, Joao; Pope, Laura E; Matsumoto, Rae R

    2016-08-01

    Dextromethorphan (DM) has been used for more than 50years as an over-the-counter antitussive. Studies have revealed a complex pharmacology of DM with mechanisms beyond blockade of N-methyl-d-aspartate (NMDA) receptors and inhibition of glutamate excitotoxicity, likely contributing to its pharmacological activity and clinical potential. DM is rapidly metabolized to dextrorphan, which has hampered the exploration of DM therapy separate from its metabolites. Coadministration of DM with a low dose of quinidine inhibits DM metabolism, yields greater bioavailability and enables more specific testing of the therapeutic properties of DM apart from its metabolites. The development of the drug combination DM hydrobromide and quinidine sulfate (DM/Q), with subsequent approval by the US Food and Drug Administration for pseudobulbar affect, led to renewed interest in understanding DM pharmacology. This review summarizes the interactions of DM with brain receptors and transporters and also considers its metabolic and pharmacokinetic properties. To assess the potential clinical relevance of these interactions, we provide an analysis comparing DM activity from in vitro functional assays with the estimated free drug DM concentrations in the brain following oral DM/Q administration. The findings suggest that DM/Q likely inhibits serotonin and norepinephrine reuptake and also blocks NMDA receptors with rapid kinetics. Use of DM/Q may also antagonize nicotinic acetylcholine receptors, particularly those composed of α3β4 subunits, and cause agonist activity at sigma-1 receptors. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Clinical relevance is associated with allergen-specific wheal size in skin prick testing

    DEFF Research Database (Denmark)

    Haahtela, T.; Burbach, G. J.; Bachert, C.

    2014-01-01

    , asthma, atopic dermatitis, food allergy). The effects of age, gender, and geographical area on SPT results were assessed. For each allergen, the wheal size in mm with an 80% positive predictive value (PPV) for being clinically relevant was calculated. ResultsDepending on the allergen, from 40% (blatella...... by providing quantitative decision points. MethodsThe GA(2)LEN SPT study with 3068 valid data sets was used to investigate the relationship between SPT results and patient-reported clinical relevance for each of the 18 inhalant allergens as well as SPT wheal size and physician-diagnosed allergy (rhinitis...... SPT reactions had a smaller risk of sensitizations being clinically relevant compared with adults. The 80% PPV varied from 3 to 10mm depending on the allergen. ConclusionThese reading keys' for 18 inhalant allergens can help interpret SPT results with respect to their clinical significance. A SPT form...

  16. Vitamin E-drug interactions: molecular basis and clinical relevance.

    Science.gov (United States)

    Podszun, Maren; Frank, Jan

    2014-12-01

    Vitamin E (α-, β-, γ- and δ-tocopherol and -tocotrienol) is an essential factor in the human diet and regularly taken as a dietary supplement by many people, who act under the assumption that it may be good for their health and can do no harm. With the publication of meta-analyses reporting increased mortality in persons taking vitamin E supplements, the safety of the micronutrient was questioned and interactions with prescription drugs were suggested as one potentially underlying mechanism. Here, we review the evidence in the scientific literature for adverse vitamin E-drug interactions and discuss the potential of each of the eight vitamin E congeners to alter the activity of drugs. In summary, there is no evidence from animal models or randomised controlled human trials to suggest that the intake of tocopherols and tocotrienols at nutritionally relevant doses may cause adverse nutrient-drug interactions. Consumption of high-dose vitamin E supplements ( ≥  300 mg/d), however, may lead to interactions with the drugs aspirin, warfarin, tamoxifen and cyclosporine A that may alter their activities. For the majority of drugs, however, interactions with vitamin E, even at high doses, have not been observed and are thus unlikely.

  17. Radioactive concentrations in foodstuffs and the ingestion dose from Romanian relevant diets

    International Nuclear Information System (INIS)

    Ferdes, O.

    1994-01-01

    Radioactivity measurements of fresh fruits and vegetables, grains (wheat and bread), milk (cheese), meat and meat products from different areas have been done. High-resolution low-level gamma-ray spectrometry, low-level beta total analysis and radiochemical techniques were used. Many radionuclides, both man-made and natural, have been identified. Only a few of them (the man-made Cs, I and Sr as well as the natural 40 K, 7 Be, etc) were of biological importance. In order to predict the ingestion dose, it had to be studied the general pathway of radionuclides to man, including a transfer model to agricultural products and the processes involved in food chain contamination. Modelling the radionuclide behaviour included retention, radioactive decay, metabolic processes and retention after processing. Relevant aspects related to translocation, agricultural practices and food processing were also considered. The human dose due to radioactive intake could be assessed on the basis of a simplified model for radionuclide ingestion and assimilation, considering local conditions and specific diets. As a result the average diets were determined depending on geographical areas (urban, rural, plain and uphill) and age (children, youngsters and adults). The estimated values for yearly ingestion dose vary from a few mSv to tens of mSv (as in the case of 1986 and 1987). (author)

  18. Clinical relevance of narrow-band imaging in flexible cystoscopy

    DEFF Research Database (Denmark)

    Drejer, Ditte; Béji, Sami; Munk Nielsen, Anna

    2017-01-01

    urological departments. Patients had either hematuria (n = 483) or known recurrent non-muscle-invasive bladder cancer (NMIBC) (n = 472). High-definition (HD) cystoscopy was performed in white light (WL) and a preliminary clinical decision was made. Then, a second cystoscopy was performed in NBI...... in NBI compared to WL (NBI: 100.0% vs WL: 83.2%, p decision making as a supplement to WL because it yields a significantly higher...... and a conclusive clinical decision was made. A difference between the two decisions that had a clinical impact on the patient was considered clinically relevant. RESULTS: Pathology was found in 216 WL cystoscopies, and additional pathology in 15 NBI cystoscopies (6.9%). Based on NBI, pathology was suspected in 23...

  19. Clinical use of carbon-loaded thermoluminescent dosimeters for skin dose determination

    International Nuclear Information System (INIS)

    Ostwald, Patricia M.; Kron, Tomas; Hamilton, Christopher S.; Denham, James W.

    1995-01-01

    Purpose: Carbon-loaded thermoluminescent dosimeters (TLDs) are designed for surface/skin dose measurements. Following 4 years in clinical use at the Mater Hospital, the accuracy and clinical usefulness of the carbon-loaded TLDs was assessed. Methods and Materials: Teflon-based carbon-loaded lithium fluoride (LiF) disks with a diameter of 13 mm were used in the present study. The TLDs were compared with ion chamber readings and TLD extrapolation to determine the effective depth of the TLD measurement. In vivo measurements were made on patients receiving open-field treatments to the chest, abdomen, and groin. Skin entry dose or entry and exit dose were assessed in comparison with doses estimated from phantom measurements. Results: The effective depth of measurement in a 6 MV therapeutic x-ray beam was found to be about 0.10 mm using TLD extrapolation as a comparison. Entrance surface dose measurements made on a solid water phantom agreed well with ion chamber and TLD extrapolation measurements, and black TLDs provide a more accurate exit dose than the other methods. Under clinical conditions, the black TLDs have an accuracy of ± 5% (± 2 SD). The dose predicted from black TLD readings correlate with observed skin reactions as assessed with reflectance spectroscopy. Conclusion: In vivo dosimetry with carbon-loaded TLDs proved to be a useful tool in assessing the dose delivered to the basal cell layer in the skin of patients undergoing radiotherapy

  20. Application of ICRP recommendations relevant to internal dose

    International Nuclear Information System (INIS)

    Cowser, K.E.; Snyder, W.S.; Struxness, E.G.

    1969-01-01

    The intent of this paper is to review several of the basic concepts of radiation protection (with emphasis on internal dose) currently recommended by the International Commission on radiological Protection (ICRP), to summarize the assumptions and methods used in the calculation of internal dose, and to illustrate by example the practical application of the pertinent guidelines. Two broad subject areas are considered: (1) standards of radiation protection and (2) bases of internal dose estimation. Topics discussed within the framework of radiation protection standards include maximum permissible dose, categories of radiation exposure, maximum permissible dose commitment, simultaneous internal and external exposure, multiple organ exposure, and size of the exposed group. Discussion of internal dose estimation is limited to selected items that include the body burden of radionuclides and the calculation of absorbed dose, the dose equivalent, the derivation of maximum permissible concentration (MPC), the relationship of stable element intake to the MPC, and short term and chronic exposure situations. (author)

  1. Application of ICRP recommendations relevant to internal dose

    Energy Technology Data Exchange (ETDEWEB)

    Cowser, K E; Snyder, W S; Struxness, E G [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1969-07-01

    The intent of this paper is to review several of the basic concepts of radiation protection (with emphasis on internal dose) currently recommended by the International Commission on radiological Protection (ICRP), to summarize the assumptions and methods used in the calculation of internal dose, and to illustrate by example the practical application of the pertinent guidelines. Two broad subject areas are considered: (1) standards of radiation protection and (2) bases of internal dose estimation. Topics discussed within the framework of radiation protection standards include maximum permissible dose, categories of radiation exposure, maximum permissible dose commitment, simultaneous internal and external exposure, multiple organ exposure, and size of the exposed group. Discussion of internal dose estimation is limited to selected items that include the body burden of radionuclides and the calculation of absorbed dose, the dose equivalent, the derivation of maximum permissible concentration (MPC), the relationship of stable element intake to the MPC, and short term and chronic exposure situations. (author)

  2. GA(2)LEN skin test study II: clinical relevance of inhalant allergen sensitizations in Europe

    DEFF Research Database (Denmark)

    Burbach, G J; Heinzerling, L M; Edenharter, G

    2009-01-01

    BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance was ...... the clinical relevance of positive skin prick tests and calls for further studies, which may, ultimately, help increase the positive predictive value of allergy testing.......BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance...... was used to determine the clinical relevance of sensitizations against the 18 most frequent inhalant allergens in Europe. The study population consisted of patients referred to one of the 17 allergy centres in 14 European countries (n = 3034, median age = 33 years). The aim of the study was to assess...

  3. A method to adjust radiation dose-response relationships for clinical risk factors

    DEFF Research Database (Denmark)

    Appelt, Ane Lindegaard; Vogelius, Ivan R

    2012-01-01

    Several clinical risk factors for radiation induced toxicity have been identified in the literature. Here, we present a method to quantify the effect of clinical risk factors on radiation dose-response curves and apply the method to adjust the dose-response for radiation pneumonitis for patients...

  4. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning

    International Nuclear Information System (INIS)

    Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon

    2003-01-01

    Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely

  5. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the

  6. Comparison of doses delivered in clinical trials of neutron capture therapy in the USA

    International Nuclear Information System (INIS)

    Albritton, J.R.; Binns, P.J.; Riley, K.J.; Coderre, J.A.; Harling, O.K.; Kiger, W.S. III

    2006-01-01

    A combined 81 brain tumor patients have been treated in dose escalation trials of Neutron Capture Therapy (NCT) at Harvard-MIT and Brookhaven National Laboratory (BNL). Pooling the clinical outcomes from these trials will permit evaluation with more statistical rigor. However, differences in physical and computational dosimetry between the institutions make direct comparison of the clinical dosimetry difficult. This paper describes work performed to normalize the BNL clinical dosimetry to that of Harvard-MIT for combined dose response analysis. This normalization involved analysis of MIT measurements and calculations using the BNL treatment planning system (TPS), BNCT - Rtpe, for two different phantoms. The BNL TPS was calibrated to dose measurements made by MIT at the BMRR in the BNL calibration phantom, a Lucite cube, and then validated by MIT dose measurements at the BMMR in an ellipsoidal water phantom. Treatment plans for all BNL patients were recomputed using the newly determined TPS calibration, yielding reductions in reported mean brain doses of 19% on average in the initial 15 patients and 31% in the latter 38 patients. These reductions in reported doses have clinically significant implications for those relying on reported BNL doses as a basis for initial dose selection in clinical studies. (author)

  7. Clinically relevant doses of lidocaine and bupivacaine do not impair cutaneous wound healing in mice.

    Science.gov (United States)

    Waite, A; Gilliver, S C; Masterson, G R; Hardman, M J; Ashcroft, G S

    2010-06-01

    Lidocaine and bupivacaine are commonly infiltrated into surgical cutaneous wounds to provide local anaesthesia after surgical procedures. However, very little is known about their effects on cutaneous wound healing. If an inhibitory effect is demonstrated, then the balance between the benefits of postoperative local anaesthesia and the negatives of impaired cutaneous wound healing may affect the decision to use local anaesthesia or not. Furthermore, if a difference in the rate of healing of lidocaine- and bupivacaine-treated cutaneous wounds is revealed, or if an inhibitory effect is found to be dose-dependent, then this may well influence the choice of agent and its concentration for clinical use. Immediately before incisional wounding, we administered lidocaine and bupivacaine intradermally to adult female mice, some of which had been ovariectomized to act as a model of post-menopausal women (like post-menopausal women, ovariectomized mice heal wounds poorly, with increased proteolysis and inflammation). Day 3 wound tissue was analysed histologically and tested for expression of inflammatory and proteolytic factors. On day 3 post-wounding, wound areas and extent of re-epithelialization were comparable between the control and local anaesthetic-treated animals, in both intact and ovariectomized groups. Both tested drugs significantly increased wound activity of the degradative enzyme matrix metalloproteinase-2 relative to controls, while lidocaine also increased wound neutrophil numbers. Although lidocaine and bupivacaine influenced local inflammatory and proteolytic factors, they did not impair the rate of healing in either of two well-established models (mimicking normal human wound healing and impaired age-related healing).

  8. Intraductal papillary mucinous neoplasms of the pancreas: reporting clinically relevant features.

    Science.gov (United States)

    Del Chiaro, Marco; Verbeke, Caroline

    2017-05-01

    Intraductal papillary mucinous neoplasms (IPMNs) of the pancreas can exhibit a wide spectrum of macroscopic and microscopic appearances. This not only causes occasional difficulties for the reporting pathologist in distinguishing these tumours from other lesions, but is also relevant clinically. As evidence accumulates, it becomes clear that multiple macroscopic and histological features of these neoplasms are relevant to the risk for malignant transformation and, consequently, of prime importance for clinical patient management. The need for detailed reporting is therefore increasing. This review discusses the panoply of gross and microscopic features of IPMN as well as the recommendations from recent consensus meetings regarding the pathology reporting on this tumour entity. © 2016 John Wiley & Sons Ltd.

  9. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

    International Nuclear Information System (INIS)

    Rosu, Mihaela; Chetty, Indrin J.; Balter, James M.; Kessler, Marc L.; McShan, Daniel L.; Ten Haken, Randall K.

    2005-01-01

    In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the 'tracked' locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the 'volume' associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field

  10. Reliability of dose volume constraint inference from clinical data

    DEFF Research Database (Denmark)

    Lutz, C M; Møller, D S; Hoffmann, L

    2017-01-01

    Dose volume histogram points (DVHPs) frequently serve as dose constraints in radiotherapy treatment planning. An experiment was designed to investigate the reliability of DVHP inference from clinical data for multiple cohort sizes and complication incidence rates. The experimental background...... was radiation pneumonitis in non-small cell lung cancer and the DVHP inference method was based on logistic regression. From 102 NSCLC real-life dose distributions and a postulated DVHP model, an 'ideal' cohort was generated where the most predictive model was equal to the postulated model. A bootstrap...

  11. Evaluation of a clinically intuitive quality assurance method

    International Nuclear Information System (INIS)

    Norris, H; Thomas, A; Oldham, M

    2013-01-01

    There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel ''transform method'' which enables a clinically relevant analysis through dose-volume-histograms (DVHs) and dose overlays on the patient's CT data. The transform method was tested by inducing a series of known mechanical and delivery errors onto simulated 3D dosimetry measurements of six different head-and-neck IMRT treatment plans. Accuracy was then examined through the comparison of the transformed patient dose distributions and the known actual patient dose distributions through dose-volume histograms and normalized dose difference analysis. Through these metrics, the transform method was found to be highly accurate in predicting measured patient dose distributions for these types of errors.

  12. Dosimetry investigation of MOSFET for clinical IMRT dose verification.

    Science.gov (United States)

    Deshpande, Sudesh; Kumar, Rajesh; Ghadi, Yogesh; Neharu, R M; Kannan, V

    2013-06-01

    In IMRT, patient-specific dose verification is followed regularly at each centre. Simple and efficient dosimetry techniques play a very important role in routine clinical dosimetry QA. The MOSFET dosimeter offers several advantages over the conventional dosimeters such as its small detector size, immediate readout, immediate reuse, multiple point dose measurements. To use the MOSFET as routine clinical dosimetry system for pre-treatment dose verification in IMRT, a comprehensive set of experiments has been conducted, to investigate its linearity, reproducibility, dose rate effect and angular dependence for 6 MV x-ray beam. The MOSFETs shows a linear response with linearity coefficient of 0.992 for a dose range of 35 cGy to 427 cGy. The reproducibility of the MOSFET was measured by irradiating the MOSFET for ten consecutive irradiations in the dose range of 35 cGy to 427 cGy. The measured reproducibility of MOSFET was found to be within 4% up to 70 cGy and within 1.4% above 70 cGy. The dose rate effect on the MOSFET was investigated in the dose rate range 100 MU/min to 600 MU/min. The response of the MOSFET varies from -1.7% to 2.1%. The angular responses of the MOSFETs were measured at 10 degrees intervals from 90 to 270 degrees in an anticlockwise direction and normalized at gantry angle zero and it was found to be in the range of 0.98 ± 0.014 to 1.01 ± 0.014. The MOSFETs were calibrated in a phantom which was later used for IMRT verification. The measured calibration coefficients were found to be 1 mV/cGy and 2.995 mV/cGy in standard and high sensitivity mode respectively. The MOSFETs were used for pre-treatment dose verification in IMRT. Nine dosimeters were used for each patient to measure the dose in different plane. The average variation between calculated and measured dose at any location was within 3%. Dose verification using MOSFET and IMRT phantom was found to quick and efficient and well suited for a busy radiotherapy

  13. Decaying relevance of clinical data towards future decisions in data-driven inpatient clinical order sets.

    Science.gov (United States)

    Chen, Jonathan H; Alagappan, Muthuraman; Goldstein, Mary K; Asch, Steven M; Altman, Russ B

    2017-06-01

    Determine how varying longitudinal historical training data can impact prediction of future clinical decisions. Estimate the "decay rate" of clinical data source relevance. We trained a clinical order recommender system, analogous to Netflix or Amazon's "Customers who bought A also bought B..." product recommenders, based on a tertiary academic hospital's structured electronic health record data. We used this system to predict future (2013) admission orders based on different subsets of historical training data (2009 through 2012), relative to existing human-authored order sets. Predicting future (2013) inpatient orders is more accurate with models trained on just one month of recent (2012) data than with 12 months of older (2009) data (ROC AUC 0.91 vs. 0.88, precision 27% vs. 22%, recall 52% vs. 43%, all P<10 -10 ). Algorithmically learned models from even the older (2009) data was still more effective than existing human-authored order sets (ROC AUC 0.81, precision 16% recall 35%). Training with more longitudinal data (2009-2012) was no better than using only the most recent (2012) data, unless applying a decaying weighting scheme with a "half-life" of data relevance about 4 months. Clinical practice patterns (automatically) learned from electronic health record data can vary substantially across years. Gold standards for clinical decision support are elusive moving targets, reinforcing the need for automated methods that can adapt to evolving information. Prioritizing small amounts of recent data is more effective than using larger amounts of older data towards future clinical predictions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT

    International Nuclear Information System (INIS)

    Wiel, J.C.M. van de; Wang, Y.; Xu, D.M.; Zaag-Loonen, H.J. van der; Jagt, E.J. van der; Oudkerk, M.; Klaveren, R.J. van

    2007-01-01

    The purpose of this study was to prospectively determine the frequency and spectrum of incidental findings (IFs) and their clinical implications in a high risk population for lung cancer undergoing low-dose multidetector computed tomography (MDCT) screening for lung cancer. Scans of 1,929 participants were evaluated for lung lesions and IFs by two radiologists. IFs were categorised as not clinically relevant or possibly clinically relevant. Findings were considered possibly clinically relevant if they could require further evaluation or could have substantial clinical implications. All possibly clinically relevant IFs were reviewed by a third radiologist, who determined its clinical relevance. Of all 1,929 participants, 1,410 (73%) had not clinically relevant IFs and 163 (8%) had possibly clinically relevant IFs of which 129 (79%) were indeed considered clinically relevant. Additional imaging was performed mainly by ultrasound (112 of 118, 96%). All but one lesion were concluded to be benign, mostly cysts (n = 115, 80%). Only 21 (1%) participants had findings with clinical implications. In one participant a malignancy was found, yet without any clinical benefit since no curative treatment was possible. Based on our results, we advise against systematically searching for and reporting of IFs in lung cancer screening studies using low-dose MDCT. (orig.)

  15. Relevance of human anatomy in daily clinical practice.

    Science.gov (United States)

    Arráez-Aybar, Luis-Alfonso; Sánchez-Montesinos, Indalecio; Mirapeix, Rosa-M; Mompeo-Corredera, Blanca; Sañudo-Tejero, Jose-Ramón

    2010-12-20

    the aim of this study has been to evaluate the relevance of gross human anatomy in daily clinical practice and to compare it to that of other basic sciences (biochemistry, bioethics, cytohistology, microbiology, pharmacology, physiology, psychology). a total of 1250 questionnaires were distributed among 38 different medical speciality professionals. Answers were analyzed taking into account speciality (medical, surgery and others), professional status (training physician or staff member) and professional experience. the response rate was 42.9% (n=536). Gross human anatomy was considered the most relevant basic discipline for surgical specialists, while pharmacology and physiology were most relevant for medical specialists. Knowledge of anatomy was also considered fundamental for understanding neurological or musculoskeletal disorders. In undergraduate programmes, the most important focuses in teaching anatomy were radiological, topographical and functional anatomy followed by systematic anatomy. In daily medical practice anatomy was considered basic for physical examination, symptom interpretation and interpretation of radiological images. When professional status or professional experience was considered, small variations were shown and there were no significant differences related to gender or community. our results underline the relevance of basic sciences (gross anatomy, physiology, and pharmacology) in daily professional activity. Evidence-based studies such as ours, lend greater credibility and objectivity to the role of gross anatomy in the undergraduate training of health professionals and should help to establish a more appropriate curriculum for future professionals. 2010 Elsevier GmbH. All rights reserved.

  16. Converting dose distributions into tumour control probability

    International Nuclear Information System (INIS)

    Nahum, A.E.

    1996-01-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s a can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s a . The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs

  17. Converting dose distributions into tumour control probability

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, A E [The Royal Marsden Hospital, London (United Kingdom). Joint Dept. of Physics

    1996-08-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s{sub a} can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s{sub a}. The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs.

  18. Laboratory exercises to teach clinically relevant chemistry of antibiotics.

    Science.gov (United States)

    El Sayed, Khalid A; Chelette, Candace T

    2014-03-12

    To design, implement, and evaluate student performance on clinically relevant chemical and spectral laboratory exercises on antibiotics. In the first of 2 exercises, second-year pharmacy students enrolled in an integrated laboratory sequence course studied the aqueous stability of ß-lactam antibiotics using a spectral visual approach. In a second exercise, students studied the tendency of tetracycline, rifamycins, and fluoroquinolones to form insoluble chelate complexes (turbidity) with polyvalent metals. On a survey to assess achievement of class learning objectives, students agreed the laboratory activities helped them better retain important information concerning antibiotic stability and interactions. A significant improvement was observed in performance on examination questions related to the laboratory topics for 2012 and 2013 students compared to 2011 students who did not complete the laboratory. A 1-year follow-up examination question administered in a separate course showed >75% of the students were able to identify rifamycins-food interactions compared with laboratory exercises. The use of spectral visual approaches allowed students to investigate antibiotic stability and interactions, thus reinforcing the clinical relevance of medicinal chemistry. Students' performance on questions at the 1-year follow-up suggested increased retention of the concepts learned as a result of completing the exercises.

  19. The clinic and pathologic picture in the lethal dose irradiated ewes

    International Nuclear Information System (INIS)

    Halagan, J.; Stanikova, A.; Maracek, I.

    2004-01-01

    The history of clinical symptoms as well as pathologic histological and morphological changes after long/lasting gamma irradiation were estimated in seven clinical healthy ewes. The animals were irradiated continually seven days with totally 6.7 Gy per ewe. Clinically recognizable symptoms of the radiation sickness were observed commencing the 4 th after last dose of irradiation. Sharp increase of the body temperature, heart and respiratory frequency rate as well as apathy, anorexia, arrhythmia, dyspnoe, diarrhea, dehydration, polyuria were prevalent in clinical founding . All of the animals were death in course of seven days after last irradiated dose. The gastrointestinal radiation syndrome was typical evidence of gastrointestinal tract and the general hemorrhagic enhancing of the gamma irradiation damage effects was confirmed. (authors)

  20. Validation of clinical testing for warfarin sensitivity: comparison of CYP2C9-VKORC1 genotyping assays and warfarin-dosing algorithms.

    Science.gov (United States)

    Langley, Michael R; Booker, Jessica K; Evans, James P; McLeod, Howard L; Weck, Karen E

    2009-05-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 -1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses.

  1. Clinical Relevance of Discourse Characteristics after Right Hemisphere Brain Damage

    Science.gov (United States)

    Blake, Margaret Lehman

    2006-01-01

    Purpose: Discourse characteristics of adults with right hemisphere brain damage are similar to those reported for healthy older adults, prompting the question of whether changes are due to neurological lesions or normal aging processes. The clinical relevance of potential differences across groups was examined through ratings by speech-language…

  2. There’s an App for That? Highlighting the Difficulty in Finding Clinically Relevant Smartphone Applications

    Directory of Open Access Journals (Sweden)

    Warren Wiechmann, MD, MBA

    2016-03-01

    Full Text Available Introduction: The use of personal mobile devices in the medical field has grown quickly, and a large proportion of physicians use their mobile devices as an immediate resource for clinical decisionmaking, prescription information and other medical information. The iTunes App Store (Apple, Inc. contains approximately 20,000 apps in its “Medical” category, providing a robust repository of resources for clinicians; however, this represents only 2% of the entire App Store. The App Store does not have strict criteria for identifying content specific to practicing physicians, making the identification of clinically relevant content difficult. The objective of this study is to quantify the characteristics of existing medical applications in the iTunes App Store that could be used by emergency physicians, residents, or medical students. Methods: We found applications related to emergency medicine (EM by searching the iTunes App Store for 21 terms representing core content areas of EM, such as “emergency medicine,” “critical care,” “orthopedics,” and “procedures.” Two physicians independently reviewed descriptions of these applications in the App Store and categorized each as the following: Clinically Relevant, Book/ Published Source, Non-English, Study Tools, or Not Relevant. A third physician reviewer resolved disagreements about categorization. Descriptive statistics were calculated. Results: We found a total of 7,699 apps from the 21 search terms, of which 17.8% were clinical, 9.6% were based on a book or published source, 1.6% were non-English, 0.7% were clinically relevant patient education resources, and 4.8% were study tools. Most significantly, 64.9% were considered not relevant to medical professionals. Clinically relevant apps make up approximately 6.9% of the App Store’s “Medical” Category and 0.1% of the overall App Store. Conclusion: Clinically relevant apps represent only a small percentage (6.9% of the total App

  3. Extracellular vesicles: fundamentals and clinical relevance

    Directory of Open Access Journals (Sweden)

    Wael Nassar

    2015-01-01

    Full Text Available All types of cells of eukaryotic organisms produce and release small nanovesicles into their extracellular environment. Early studies have described these vesicles as ′garbage bags′ only to remove obsolete cellular molecules. Valadi and colleagues, in 2007, were the first to discover the capability of circulating extracellular vesicles (EVs to horizontally transfer functioning gene information between cells. These extracellular vesicles express components responsible for angiogenesis promotion, stromal remodeling, chemoresistance, genetic exchange, and signaling pathway activation through growth factor/receptor transfer. EVs represent an important mode of intercellular communication by serving as vehicles for transfer between cells of membrane and cytosolic proteins, lipids, signaling proteins, and RNAs. They contribute to physiology and pathology, and they have a myriad of potential clinical applications in health and disease. Moreover, vesicles can pass the blood-brain barrier and may perhaps even be considered as naturally occurring liposomes. These cell-derived EVs not only represent a central mediator of the disease microenvironment, but their presence in the peripheral circulation may serve as a surrogate for disease biopsies, enabling real-time diagnosis and disease monitoring. In this review, we′ll be addressing the characteristics of different types of extracellular EVs, as well as their clinical relevance and potential as diagnostic markers, and also define therapeutic options.

  4. Cerebral activation studies by PET and fMRT, clinical relevance?

    International Nuclear Information System (INIS)

    Brandt, T.

    1997-01-01

    Cerebral activation studies by PET and fMRT will gain increasing clinical relevance for functional neuroanatomy (reading, speaking), localisation of largely unknown cortical functions (vestibular cortex), imaging of subjective complaints of functional impairments (pain, smell, memory), and documentation of neurological rehabilitation at neuronal level (regeneration, compensation, substitution, learning). (orig.) [de

  5. Energy and integrated dose dependence of MOSFET dosimeter for clinical electron beams

    International Nuclear Information System (INIS)

    Manigandan, D.; Bharanidharan, G.; Aruna, P.; Ganesan, S.; Tamil Kumar, T.; Rai

    2008-01-01

    In this study, the sensitivity (mV/cGy) and integral dose dependence of a MOSFET detector for different clinical electron beams was studied. Calibrated clinical electron beams (Varian 2100) were used for the exposure. A Markus type parallel plate chamber was used for the absolute dose measurements. In order to study the sensitivity of a MOSFET, the response of the ion chamber and MOSFET for the absorbed dose of 100 cGy was measured. The sensitivity of the MOSFET was then expressed as mV/cGy. Sensitivity was measured for 4-18 MeV electron beams. (author)

  6. SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

    International Nuclear Information System (INIS)

    Ma, T; Kumaraswamy, L

    2015-01-01

    Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect

  7. Depression of home cage wheel running: a reliable and clinically relevant method to assess migraine pain in rats.

    Science.gov (United States)

    Kandasamy, Ram; Lee, Andrea T; Morgan, Michael M

    2017-12-01

    The development of new anti-migraine treatments is limited by the difficulty inassessing migraine pain in laboratory animals. Depression of activity is one of the few diagnostic criteria formigraine that can be mimicked in rats. The goal of the present study was to test the hypothesis thatdepression of home cage wheel running is a reliable and clinically relevant method to assess migraine painin rats. Adult female rats were implanted with a cannula to inject allyl isothiocyanate (AITC) onto the dura to induce migraine pain, as has been shown before. Rats recovered from implantation surgery for 8 days in cages containing a running wheel. Home cage wheel running was recorded 23 h a day. AITC and the migraine medication sumatriptan were administered in the hour prior to onset of the dark phase. Administration of AITC caused a concentration-dependent decrease in wheel running that lasted 3 h. The duration and magnitude of AITC-induced depression of wheel running was consistent following three repeated injections spaced 48 h apart. Administration of sumatriptan attenuated AITC-induced depressionof wheel running when a large dose (1 mg/kg) was administered immediately following AITC administration. Wheel running patterns did not change when sumatriptan was given to naïve rats. These data indicate that home cage wheel running is a sensitive, reliable, and clinically relevant method to assess migraine pain in the rat.

  8. Optimal medication dosing from suboptimal clinical examples: a deep reinforcement learning approach.

    Science.gov (United States)

    Nemati, Shamim; Ghassemi, Mohammad M; Clifford, Gari D

    2016-08-01

    Misdosing medications with sensitive therapeutic windows, such as heparin, can place patients at unnecessary risk, increase length of hospital stay, and lead to wasted hospital resources. In this work, we present a clinician-in-the-loop sequential decision making framework, which provides an individualized dosing policy adapted to each patient's evolving clinical phenotype. We employed retrospective data from the publicly available MIMIC II intensive care unit database, and developed a deep reinforcement learning algorithm that learns an optimal heparin dosing policy from sample dosing trails and their associated outcomes in large electronic medical records. Using separate training and testing datasets, our model was observed to be effective in proposing heparin doses that resulted in better expected outcomes than the clinical guidelines. Our results demonstrate that a sequential modeling approach, learned from retrospective data, could potentially be used at the bedside to derive individualized patient dosing policies.

  9. Taijin kyofusho and social anxiety and their clinical relevance in indonesia and Switzerland.

    Science.gov (United States)

    Vriends, N; Pfaltz, M C; Novianti, P; Hadiyono, J

    2013-01-01

    Taijin Kyofusho Scale (TKS) is an interpersonal fear to offend others and is defined by Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) as a culturally bound syndrome that occurs in Japan and Korea. Recently, cases with TKS have also been recognized in other cultures. The present questionnaire study investigated self-report TKS symptoms and social anxiety symptoms, and their clinical relevance in an Indonesian and Swiss sample. It also investigated whether self-construal is associated with TKS and social anxiety, and if self-construal is a mediator of the expected association between cultural background and social anxiety and TKS symptoms. 311 Indonesian and 349 Swiss university students filled out the Liebowitz Social Anxiety Scale, the Taijin Kyofusho Scale, the Self-Construal Scale, self-report social phobia DSM-IV criteria, and rated their wish for professional help to deal with social fears. TKS and social anxiety symptoms were higher in the Indonesian than the Swiss sample. TKS symptoms were associated with clinical relevance in Indonesia, whereas in Switzerland only social anxiety symptoms were associated with clinical relevance. Independent self-construal was negatively associated and interdependent self-construal was positively associated with TKS and social anxiety symptoms. Interdependent self-construal mediated the association between cultural background and these symptoms. TKS might be a clinically relevant syndrome in all individuals or cultures with an interdependent self-construal or less independent self-construal. The proposal to include the fear of offending others in the DSM-V criteria of social phobia is supported by the present findings.

  10. Taijin Kyofusho and Social Anxiety and their clinical relevance in Indonesia and Switzerland

    Directory of Open Access Journals (Sweden)

    Noortje eVriends

    2013-02-01

    Full Text Available Background: Taijin Kyofusho (TKS is an interpersonal fear to offend others and is defined by DSM-IV as a culturally bound syndrome that occurs in Japan and Korea. Recently, cases with TKS have also been recognized in other cultures. The present questionnaire study investigated self-report TKS symptoms and social anxiety symptoms, and their clinical relevance in an Indonesian and Swiss sample. It also investigated if self-construal is associated with TKS and social anxiety, and if self-construal is a mediator of the expected association between cultural background and social anxiety and TKS symptoms. Method: 311 Indonesian and 349 Swiss university students filled out the Liebowitz Social Anxiety Scale, the Taijin Kyofusho Scale, the Self-Construal Scale, self-report social phobia DSM-IV criteria, and rated their wish for professional help to deal with social fears.Results: TKS and social anxiety symptoms were higher in the Indonesian than the Swiss sample. TKS symptoms were associated with clinical relevance in Indonesia, whereas in Switzerland only social anxiety symptoms were associated with clinical relevance. Independent self-construal was negatively associated and interdependent self-construal was positively associated with TKS and social anxiety symptoms. Interdependent self-construal mediated the association between cultural background and these symptoms.Discussion: TKS might be a clinically relevant syndrome in all individuals or cultures with an interdependent self-construal or less independent self-construal. The proposal to include the fear of offending others in the DSM-V criteria of social phobia is supported by the present findings.

  11. Cato Guldberg and Peter Waage, the history of the Law of Mass Action, and its relevance to clinical pharmacology.

    Science.gov (United States)

    Ferner, Robin E; Aronson, Jeffrey K

    2016-01-01

    We have traced the historical link between the Law of Mass Action and clinical pharmacology. The Law evolved from the work of the French chemist Claude Louis Berthollet, was first formulated by Cato Guldberg and Peter Waage in 1864 and later clarified by the Dutch chemist Jacobus van 't Hoff in 1877. It has profoundly influenced our qualitative and quantitative understanding of a number of physiological and pharmacological phenomena. According to the Law of Mass Action, the velocity of a chemical reaction depends on the concentrations of the reactants. At equilibrium the concentrations of the chemicals involved bear a constant relation to each other, described by the equilibrium constant, K. The Law of Mass Action is relevant to various physiological and pharmacological concepts, including concentration-effect curves, dose-response curves, and ligand-receptor binding curves, all of which are important in describing the pharmacological actions of medications, the Langmuir adsorption isotherm, which describes the binding of medications to proteins, activation curves for transmembrane ion transport, enzyme inhibition and the Henderson-Hasselbalch equation, which describes the relation between pH, as a measure of acidity and the concentrations of the contributory acids and bases. Guldberg and Waage recognized the importance of dynamic equilibrium, while others failed to do so. Their ideas, over 150 years old, are embedded in and still relevant to clinical pharmacology. Here we explain the ideas and in a subsequent paper show how they are relevant to understanding adverse drug reactions. © 2015 The British Pharmacological Society.

  12. Methylphenidate dose optimization for ADHD treatment: review of safety, efficacy, and clinical necessity

    Directory of Open Access Journals (Sweden)

    Huss M

    2017-07-01

    Full Text Available Michael Huss,1 Praveen Duhan,2 Preetam Gandhi,3 Chien-Wei Chen,4 Carsten Spannhuth,3 Vinod Kumar5 1Child and Adolescent Psychiatry, University Medicine, Mainz, Germany; 2Global Medical Affairs, Novartis Healthcare Pvt. Ltd., Hyderabad, India; 3Development Franchise, Established Medicine Neuroscience, Novartis Pharma AG, Basel, Switzerland; 4Biostatistics Cardio-Metabolic & Established Medicine, Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA; 5Established Medicines, Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA Abstract: Attention-deficit/hyperactivity disorder (ADHD is a chronic psychiatric disorder characterized by hyperactivity and/or inattention and is often associated with a substantial impact on psychosocial functioning. Methylphenidate (MPH, a central nervous system stimulant, is commonly used for pharmacological treatment of adults and children with ADHD. Current practice guidelines recommend optimizing MPH dosage to individual patient needs; however, the clinical benefits of individual dose optimization compared with fixed-dose regimens remain unclear. Here we review the available literature on MPH dose optimization from clinical trials and real-world experience on ADHD management. In addition, we report safety and efficacy data from the largest MPH modified-release long-acting Phase III clinical trial conducted to examine benefits of dose optimization in adults with ADHD. Overall, MPH is an effective ADHD treatment with a good safety profile; data suggest that dose optimization may enhance the safety and efficacy of treatment. Further research is required to establish the extent to which short-term clinical benefits of MPH dose optimization translate into improved long-term outcomes for patients with ADHD. Keywords: methylphenidate, dose optimization, attention-deficit/hyperactivity disorder, ADHD

  13. Clinical relevance of liquid chromatography tandem mass spectrometry as an analytical method in microdose clinical studies.

    Science.gov (United States)

    Yamane, Naoe; Tozuka, Zenzaburo; Kusama, Makiko; Maeda, Kazuya; Ikeda, Toshihiko; Sugiyama, Yuichi

    2011-08-01

    To investigate the potency of LC-MS/MS by means of sensitivity and the applicability for cassette dosing in microdose clinical trials. Thirty one top-selling 31 drugs were spiked to human plasma, extracted, and analyzed by LC-MS/MS. The lower limits of quantification for each drug varied from 0.08 to 50 pg/mL, and were lower than one eighth of the assumed maximum plasma concentration at microdose in all drugs except for losartan, indicating the high performance in acquisition of full pharmacokinetic profiles at microdose. We also succeeded in simultaneous analysis of multiple compounds, assuming a situation of cassette dosing in which multiple drug candidates would be administrated simultaneously. Together with the features of LC-MS/MS, such as immediate verification, the utilization of non-radiolabeled drugs and no special facilities, we suppose that LC-MS/MS analysis would be widely applicable in conducting microdose clinical studies.

  14. A snapshot of patients' awareness of radiation dose and risks associated with medical imaging examinations at an Australian radiology clinic.

    Science.gov (United States)

    Singh, N; Mohacsy, A; Connell, D A; Schneider, M E

    2017-05-01

    Cumulative radiation exposure is linked to increasing the lifetime attributable risk of cancer. To avoid unnecessary radiation exposure and facilitate shared decision making, patients should be aware of these issues. This paper examines patients' awareness of radiation dose and risks associated with medical imaging examinations. Consecutive patients attending a private radiology clinic over a nine week period in 2014 in Metropolitan Melbourne were surveyed while waiting to undergo an imaging examination. Patients who were under 18 years of age, did not speak English and/or were referred for interventional imaging procedures were excluded from participation. Survey questions addressed patients' awareness of radiation dose associated with various imaging modalities' and patients' experience and preferences regarding communication of information about radiation. Data was analysed using SPSS (Ver 20.1). A total of 242 surveys were completed. Most participants were male (143/239, 59.8%) and aged between 33 and 52 years (109/242, 45%). Over half of participants were not concerned about radiation from medical imaging (130/238, 54.6%). Only a third of participants (80/234, 34.2%) correctly reported that CT has a higher radiation dose than X-ray. Very few participants correctly identified mammography, DEXA, PET and PET/CT as radiation emitting examinations. The majority of participants (202/236, 85.6%) indicated that they were not informed about radiation dose and risks by their referring doctor in advance. This paper provides information relevant to a single private radiology clinic in Australia. Nevertheless, our results have shown that patients presenting for medical imaging have little awareness of radiation dose and risks associated with these examinations and received little information by their referring physicians or staff at the radiology clinic. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  15. SU-G-BRC-15: The Potential Clinical Significance of Dose Mapping Error for Intra- Fraction Dose Mapping for Lung Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Sayah, N [Thomas Cancer Center, Richmond, VA (United States); Weiss, E [Virginia Commonwealth University, Richmond, Virginia (United States); Watkins, W [University of Virginia, Charlottesville, VA (United States); Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM); an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is

  16. Technological Advances in Cardiovascular Safety Assessment Decrease Preclinical Animal Use and Improve Clinical Relevance.

    Science.gov (United States)

    Berridge, Brian R; Schultze, A Eric; Heyen, Jon R; Searfoss, George H; Sarazan, R Dustan

    2016-12-01

    Cardiovascular (CV) safety liabilities are significant concerns for drug developers and preclinical animal studies are predominately where those liabilities are characterized before patient exposures. Steady progress in technology and laboratory capabilities is enabling a more refined and informative use of animals in those studies. The application of surgically implantable and telemetered instrumentation in the acute assessment of drug effects on CV function has significantly improved historical approaches that involved anesthetized or restrained animals. More chronically instrumented animals and application of common clinical imaging assessments like echocardiography and MRI extend functional and in-life structural assessments into the repeat-dose setting. A growing portfolio of circulating CV biomarkers is allowing longitudinal and repeated measures of cardiac and vascular injury and dysfunction better informing an understanding of temporal pathogenesis and allowing earlier detection of undesirable effects. In vitro modeling systems of the past were limited by their lack of biological relevance to the in vivo human condition. Advances in stem cell technology and more complex in vitro modeling platforms are quickly creating more opportunity to supplant animals in our earliest assessments for liabilities. Continuing improvement in our capabilities in both animal and nonanimal modeling should support a steady decrease in animal use for primary liability identification and optimize the translational relevance of the animal studies we continue to do. © The Author 2016. Published by Oxford University Press on behalf of the Institute for Laboratory Animal Research. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Islet Oxygen Consumption Rate (OCR) Dose Predicts Insulin Independence in Clinical Islet Autotransplantation.

    Science.gov (United States)

    Papas, Klearchos K; Bellin, Melena D; Sutherland, David E R; Suszynski, Thomas M; Kitzmann, Jennifer P; Avgoustiniatos, Efstathios S; Gruessner, Angelika C; Mueller, Kathryn R; Beilman, Gregory J; Balamurugan, Appakalai N; Loganathan, Gopalakrishnan; Colton, Clark K; Koulmanda, Maria; Weir, Gordon C; Wilhelm, Josh J; Qian, Dajun; Niland, Joyce C; Hering, Bernhard J

    2015-01-01

    Reliable in vitro islet quality assessment assays that can be performed routinely, prospectively, and are able to predict clinical transplant outcomes are needed. In this paper we present data on the utility of an assay based on cellular oxygen consumption rate (OCR) in predicting clinical islet autotransplant (IAT) insulin independence (II). IAT is an attractive model for evaluating characterization assays regarding their utility in predicting II due to an absence of confounding factors such as immune rejection and immunosuppressant toxicity. Membrane integrity staining (FDA/PI), OCR normalized to DNA (OCR/DNA), islet equivalent (IE) and OCR (viable IE) normalized to recipient body weight (IE dose and OCR dose), and OCR/DNA normalized to islet size index (ISI) were used to characterize autoislet preparations (n = 35). Correlation between pre-IAT islet product characteristics and II was determined using receiver operating characteristic analysis. Preparations that resulted in II had significantly higher OCR dose and IE dose (p<0.001). These islet characterization methods were highly correlated with II at 6-12 months post-IAT (area-under-the-curve (AUC) = 0.94 for IE dose and 0.96 for OCR dose). FDA/PI (AUC = 0.49) and OCR/DNA (AUC = 0.58) did not correlate with II. OCR/DNA/ISI may have some utility in predicting outcome (AUC = 0.72). Commonly used assays to determine whether a clinical islet preparation is of high quality prior to transplantation are greatly lacking in sensitivity and specificity. While IE dose is highly predictive, it does not take into account islet cell quality. OCR dose, which takes into consideration both islet cell quality and quantity, may enable a more accurate and prospective evaluation of clinical islet preparations.

  18. Islet Oxygen Consumption Rate (OCR Dose Predicts Insulin Independence in Clinical Islet Autotransplantation.

    Directory of Open Access Journals (Sweden)

    Klearchos K Papas

    Full Text Available Reliable in vitro islet quality assessment assays that can be performed routinely, prospectively, and are able to predict clinical transplant outcomes are needed. In this paper we present data on the utility of an assay based on cellular oxygen consumption rate (OCR in predicting clinical islet autotransplant (IAT insulin independence (II. IAT is an attractive model for evaluating characterization assays regarding their utility in predicting II due to an absence of confounding factors such as immune rejection and immunosuppressant toxicity.Membrane integrity staining (FDA/PI, OCR normalized to DNA (OCR/DNA, islet equivalent (IE and OCR (viable IE normalized to recipient body weight (IE dose and OCR dose, and OCR/DNA normalized to islet size index (ISI were used to characterize autoislet preparations (n = 35. Correlation between pre-IAT islet product characteristics and II was determined using receiver operating characteristic analysis.Preparations that resulted in II had significantly higher OCR dose and IE dose (p<0.001. These islet characterization methods were highly correlated with II at 6-12 months post-IAT (area-under-the-curve (AUC = 0.94 for IE dose and 0.96 for OCR dose. FDA/PI (AUC = 0.49 and OCR/DNA (AUC = 0.58 did not correlate with II. OCR/DNA/ISI may have some utility in predicting outcome (AUC = 0.72.Commonly used assays to determine whether a clinical islet preparation is of high quality prior to transplantation are greatly lacking in sensitivity and specificity. While IE dose is highly predictive, it does not take into account islet cell quality. OCR dose, which takes into consideration both islet cell quality and quantity, may enable a more accurate and prospective evaluation of clinical islet preparations.

  19. Detection of Adriamycin-DNA adducts by accelerator mass spectrometry at clinically relevant Adriamycin concentrations.

    Science.gov (United States)

    Coldwell, Kate E; Cutts, Suzanne M; Ognibene, Ted J; Henderson, Paul T; Phillips, Don R

    2008-09-01

    Limited sensitivity of existing assays has prevented investigation of whether Adriamycin-DNA adducts are involved in the anti-tumour potential of Adriamycin. Previous detection has achieved a sensitivity of a few Adriamycin-DNA adducts/10(4) bp DNA, but has required the use of supra-clinical drug concentrations. This work sought to measure Adriamycin-DNA adducts at sub-micromolar doses using accelerator mass spectrometry (AMS), a technique with origins in geochemistry for radiocarbon dating. We have used conditions previously validated (by less sensitive decay counting) to extract [(14)C]Adriamycin-DNA adducts from cells and adapted the methodology to AMS detection. Here we show the first direct evidence of Adriamycin-DNA adducts at clinically-relevant Adriamycin concentrations. [(14)C]Adriamycin treatment (25 nM) resulted in 4.4 +/- 1.0 adducts/10(7) bp ( approximately 1300 adducts/cell) in MCF-7 breast cancer cells, representing the best sensitivity and precision reported to date for the covalent binding of Adriamycin to DNA. The exceedingly sensitive nature of AMS has enabled over three orders of magnitude increased sensitivity of Adriamycin-DNA adduct detection and revealed adduct formation within an hour of drug treatment. This method has been shown to be highly reproducible for the measurement of Adriamycin-DNA adducts in tumour cells in culture and can now be applied to the detection of these adducts in human tissues.

  20. Dose escalation methods in phase I cancer clinical trials.

    Science.gov (United States)

    Le Tourneau, Christophe; Lee, J Jack; Siu, Lillian L

    2009-05-20

    Phase I clinical trials are an essential step in the development of anticancer drugs. The main goal of these studies is to establish the recommended dose and/or schedule of new drugs or drug combinations for phase II trials. The guiding principle for dose escalation in phase I trials is to avoid exposing too many patients to subtherapeutic doses while preserving safety and maintaining rapid accrual. Here we review dose escalation methods for phase I trials, including the rule-based and model-based dose escalation methods that have been developed to evaluate new anticancer agents. Toxicity has traditionally been the primary endpoint for phase I trials involving cytotoxic agents. However, with the emergence of molecularly targeted anticancer agents, potential alternative endpoints to delineate optimal biological activity, such as plasma drug concentration and target inhibition in tumor or surrogate tissues, have been proposed along with new trial designs. We also describe specific methods for drug combinations as well as methods that use a time-to-event endpoint or both toxicity and efficacy as endpoints. Finally, we present the advantages and drawbacks of the various dose escalation methods and discuss specific applications of the methods in developmental oncotherapeutics.

  1. Patient radiation dose in some dental radiography clinics in Khartoum, Sudan

    International Nuclear Information System (INIS)

    Mohamed, Aziza Hamed Abdelgadir

    2016-01-01

    Patient dose audit is an important tool for quality control and it is important for monitoring patient exposure. The DAP meter has proved to be an easy and accurate tool for patient dosimetry and for establishment of diagnostic reference levels in dental radiology. The objective of this study was measure patient dose in dental radiography in some dental radiography clinics in Khartoum. The study was performed in five dental clinics comprising six panoramic and six intraoral dental radiography devices in Khartoum state. The incident surface air kerma (k i ) and dose area product were measured for intraoral and panoramic dental examinations, respectively for digital and film imaging modalities. Incident surface air kerma (k i ) was measured using calibrated dose rate meter where dose area product were determined from dose width product (DWP) measured using 3 cc pencil type CT ionization chamber. For intraoral examinations, the maximum, average and minimum, (1.95, 1.48, and 1.24) mGy, (5.84, 4.54, and 3.6) mGy for digital and imaging, respectively. This result was lower in digital in traol and higher in film imaging. The result for panoramic examination calculated dose area product (DAP) mean value for adult and pediatric was (103, 70.42) mGy cm 2 , respectively, where the dose for digital imaging was highest in two centers, compared to previous study. Increased patient dose in intraoral dental radiography could partially be explained by the use of circular collimators. or intraoral x-ray equipment the downward trend in patient dose can only be continue, a through the adoption of digital imaging methods. Our results are relatively higher in digital panoramic dental examinations. It is important to point out that non of the dental units under study were covered by regular quality assurance programme.(Author)

  2. FDG PET and CT in locally advanced adenocarcinomas of the distal oesophagus. Clinical relevance of a discordant PET finding

    International Nuclear Information System (INIS)

    Stahl, A.; Wieder, H.; Schwaiger, M.; Weber, W.A.; Stollfuss, J.; Ott, K.; Fink, U.

    2005-01-01

    Aim: the incidence of adenocarcinomas of the distal oesophagus (ADE) has dramatically increased in Western countries. The clinical importance of a FDG PET finding discordant with CT was determined in patients with locally advanced ADE. In addition, tumour standardized uptake values (SUV) were correlated with patient survival. Patients, methods: 40 consecutive patients were analyzed retrospectively. All patients underwent an attenuation corrected FDG PET scan (neck, chest, abdomen) and contrast enhanced helical CT of the chest and abdomen. PET and CT scans were reviewed independently and concomitantly with respect to metastases in predefined lymph node sites and organs. Any discordance between PET and CT was assessed for clinical relevance. Clinical relevance was defined as a change in the overall therapeutic concept (curative vs. palliative). Follow-up imaging and histological evaluation served as the gold standard. Mean tumour SUVs were determined by 1.5 cm regions of interest placed over the tumour's maximum. Results: when read independently from the CT scan FDG PET indicated a clinically relevant change in tumour stage in 9/40 patients (23%) and a non-relevant change in 11/40 patients (28%). PET was correct in 5/9 patients (56%) with clinically relevant discordances. In 4/9 patients PET was incorrect (3 false positive due to suspicion of MI-lymph nodes or lung metastases, 1 false negative in disseminated liver metastases). With concomitant reading, PET indicated a clinically relevant change in tumour stage in 6/40 patients (15%) and a non-relevant change in 5/40 patients (13%). PET was correct in 5/6 patients (83%) with clinically relevant discordances. The patient with disseminated liver disease remained the single false negative. Overall, the benefit from PET was based on its higher diagnostic accuracy at organ sites. Tumour SUV did not correlate with patient survival. Conclusion: about half of discordances between FDG PET and CT are clinically relevant

  3. Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Senan, Suresh; De Ruysscher, Dirk; Giraud, Philippe; Mirimanoff, Rene; Budach, Volker

    2004-01-01

    Background and purpose: To review the literature on techniques used in high-dose radiotherapy of lung cancer in order to develop recommendations for clinical practice and for use in research protocols. Patients and methods: A literature search was performed for articles and abstracts that were considered both clinically relevant and practical to use. The relevant information was arbitrarily categorized under the following headings: patient positioning, CT scanning, incorporating tumour mobility, definition of target volumes, radiotherapy planning, treatment delivery, and scoring of response and toxicity. Results: Recommendations were made for each of the above steps from the published literature. Although most of the recommended techniques have yet to be evaluated in multicenter clinical trials, their use in high-dose radiotherapy to the thorax appears to be rational on the basis of current evidence. Conclusions: Recommendations for the clinical implementation of high-dose conformal radiotherapy for lung tumours were identified in the literature. Procedures that are still considered to be investigational were also highlighted

  4. Cellular recovery kinetic studies relevant to combined-modality research and therapy

    International Nuclear Information System (INIS)

    Dethlefsen, L.A.

    1979-01-01

    The relevance of cellular recovery kinetics to combined-modality therapy is evaluated within the framework of an idealized experimental flow chart and published adriamycin data. Within this context, limitations for both experimental design and data interpretations are discussed. The effects of adriamycin have been documented extensively at the molecular and cellular level and its interactions with x-irradiation have been studied, both in vitro and in vivo. The limited in vivo results suggest that the end results of a given protocol correlate with cellular recovery kinetics; however, definitive experiments simply have not been done. For example, no one has used single-dose drug and irradiation data to predict the outcome and then confirm or refute the prediction even in a relatively simple 2-dose drug + 2-dose drug + 2-dose x-ray protocol. Thus, at this time, the extent of the correlations between cellular recovery kinetics and clinical response for either normal or malignant tissues is not known and the possible relevance of such studies cannot be discounted

  5. Clinical relevance and biology of circulating tumor cells

    Science.gov (United States)

    2011-01-01

    Most breast cancer patients die due to metastases, and the early onset of this multistep process is usually missed by current tumor staging modalities. Therefore, ultrasensitive techniques have been developed to enable the enrichment, detection, isolation and characterization of disseminated tumor cells in bone marrow and circulating tumor cells in the peripheral blood of cancer patients. There is increasing evidence that the presence of these cells is associated with an unfavorable prognosis related to metastatic progression in the bone and other organs. This review focuses on investigations regarding the biology and clinical relevance of circulating tumor cells in breast cancer. PMID:22114869

  6. Clinically relevant incidental cardiovascular findings in CT examinations; Klinisch relevante kardiovaskulaere Zufallsbefunde bei CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A. [Universitaetsklinikum Leipzig, Klinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Schramm, D.; Bach, A.G. [Universitaetsklinikum Halle (Saale), Klinik fuer Radiologie, Halle (Germany)

    2017-04-15

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [German] Inzidentelle kardiovaskulaere Befunde sind ein haeufiges Phaenomen bei CT-Untersuchungen. Mit dieser Arbeit soll nach gezielter PubMed-Recherche ein systematischer Literaturueberblick ueber die wichtigsten kardiovaskulaeren Zufallsbefunde sowie deren Haeufigkeit und klinische Relevanz gegeben werden. Die Mehrzahl der inzidentellen kardiovaskulaeren Befunde sind klinisch nur von untergeordneter Bedeutung, allerdings werden immer wieder auch hochgradig relevante Zufallsbefunde wie beispielsweise Aortenaneurysmata oder - gerade bei onkologischen Patienten - Thrombosen und thrombembolische Ereignisse detektiert. Jede CT-Untersuchung sollte gezielt nach inzidentellen Befunden durchsucht werden, da diese je nach klinischer Relevanz von entscheidender Bedeutung fuer das weitere klinische Management des Patienten sein koennen. (orig.)

  7. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  8. Mirror neurons and their clinical relevance.

    Science.gov (United States)

    Rizzolatti, Giacomo; Fabbri-Destro, Maddalena; Cattaneo, Luigi

    2009-01-01

    One of the most exciting events in neurosciences over the past few years has been the discovery of a mechanism that unifies action perception and action execution. The essence of this 'mirror' mechanism is as follows: whenever individuals observe an action being done by someone else, a set of neurons that code for that action is activated in the observers' motor system. Since the observers are aware of the outcome of their motor acts, they also understand what the other individual is doing without the need for intermediate cognitive mediation. In this Review, after discussing the most pertinent data concerning the mirror mechanism, we examine the clinical relevance of this mechanism. We first discuss the relationship between mirror mechanism impairment and some core symptoms of autism. We then outline the theoretical principles of neurorehabilitation strategies based on the mirror mechanism. We conclude by examining the relationship between the mirror mechanism and some features of the environmental dependency syndromes.

  9. A snapshot of patients' awareness of radiation dose and risks associated with medical imaging examinations at an Australian radiology clinic

    International Nuclear Information System (INIS)

    Singh, N.; Mohacsy, A.; Connell, D.A.; Schneider, M.E.

    2017-01-01

    Background: Cumulative radiation exposure is linked to increasing the lifetime attributable risk of cancer. To avoid unnecessary radiation exposure and facilitate shared decision making, patients should be aware of these issues. This paper examines patients' awareness of radiation dose and risks associated with medical imaging examinations. Methods: Consecutive patients attending a private radiology clinic over a nine week period in 2014 in Metropolitan Melbourne were surveyed while waiting to undergo an imaging examination. Patients who were under 18 years of age, did not speak English and/or were referred for interventional imaging procedures were excluded from participation. Survey questions addressed patients' awareness of radiation dose associated with various imaging modalities' and patients' experience and preferences regarding communication of information about radiation. Data was analysed using SPSS (Ver 20.1). Results: A total of 242 surveys were completed. Most participants were male (143/239, 59.8%) and aged between 33 and 52 years (109/242, 45%). Over half of participants were not concerned about radiation from medical imaging (130/238, 54.6%). Only a third of participants (80/234, 34.2%) correctly reported that CT has a higher radiation dose than X-ray. Very few participants correctly identified mammography, DEXA, PET and PET/CT as radiation emitting examinations. The majority of participants (202/236, 85.6%) indicated that they were not informed about radiation dose and risks by their referring doctor in advance. Conclusion: This paper provides information relevant to a single private radiology clinic in Australia. Nevertheless, our results have shown that patients presenting for medical imaging have little awareness of radiation dose and risks associated with these examinations and received little information by their referring physicians or staff at the radiology clinic. - Highlights: • Patients' awareness regarding

  10. Clinical Pharmacogenetics Implementation Consortium (CPIC) Guideline for Pharmacogenetics-Guided Warfarin Dosing: 2017 Update.

    Science.gov (United States)

    Johnson, J A; Caudle, K E; Gong, L; Whirl-Carrillo, M; Stein, C M; Scott, S A; Lee, M T; Gage, B F; Kimmel, S E; Perera, M A; Anderson, J L; Pirmohamed, M; Klein, T E; Limdi, N A; Cavallari, L H; Wadelius, M

    2017-09-01

    This document is an update to the 2011 Clinical Pharmacogenetics Implementation Consortium (CPIC) guideline for CYP2C9 and VKORC1 genotypes and warfarin dosing. Evidence from the published literature is presented for CYP2C9, VKORC1, CYP4F2, and rs12777823 genotype-guided warfarin dosing to achieve a target international normalized ratio of 2-3 when clinical genotype results are available. In addition, this updated guideline incorporates recommendations for adult and pediatric patients that are specific to continental ancestry. © 2017 American Society for Clinical Pharmacology and Therapeutics.

  11. Automatic classification and detection of clinically relevant images for diabetic retinopathy

    Science.gov (United States)

    Xu, Xinyu; Li, Baoxin

    2008-03-01

    We proposed a novel approach to automatic classification of Diabetic Retinopathy (DR) images and retrieval of clinically-relevant DR images from a database. Given a query image, our approach first classifies the image into one of the three categories: microaneurysm (MA), neovascularization (NV) and normal, and then it retrieves DR images that are clinically-relevant to the query image from an archival image database. In the classification stage, the query DR images are classified by the Multi-class Multiple-Instance Learning (McMIL) approach, where images are viewed as bags, each of which contains a number of instances corresponding to non-overlapping blocks, and each block is characterized by low-level features including color, texture, histogram of edge directions, and shape. McMIL first learns a collection of instance prototypes for each class that maximizes the Diverse Density function using Expectation- Maximization algorithm. A nonlinear mapping is then defined using the instance prototypes and maps every bag to a point in a new multi-class bag feature space. Finally a multi-class Support Vector Machine is trained in the multi-class bag feature space. In the retrieval stage, we retrieve images from the archival database who bear the same label with the query image, and who are the top K nearest neighbors of the query image in terms of similarity in the multi-class bag feature space. The classification approach achieves high classification accuracy, and the retrieval of clinically-relevant images not only facilitates utilization of the vast amount of hidden diagnostic knowledge in the database, but also improves the efficiency and accuracy of DR lesion diagnosis and assessment.

  12. Clinical application of Chamomilla recutita in phlebitis: dose response curve study.

    Science.gov (United States)

    Reis, Paula Elaine Diniz Dos; Carvalho, Emilia Campos de; Bueno, Paula Carolina Pires; Bastos, Jairo Kenupp

    2011-01-01

    This experimental and dose-response curve study aimed to carry out the quality control of the Chamomilla recutita sample, as well as to estimate the ideal dose, for anti-inflammatory effect, of the extract of its capitula, in patients with phlebitis due to peripheral intravenous infusion of antineoplastic chemotherapy and to evaluate the toxicity of this extract in human beings. The therapeutic efficacy, concerning the anti-inflammatory potential, of different doses of Chamomilla recutita extract were analyzed and compared in 25 patients. The time of regression of phlebitis was shorter for groups with 2.5% concentration (mean=29.2h, standard deviation = 8.98) and 5% concentration (mean = 38.8h, standard deviation = 17.47). Local toxicity was almost not observed. This research contributes to the innovation of the nursing clinical practice, since it suggests an alternative for the treatment of phlebitis through the clinical use of phytotherapeutic drugs.

  13. Radiation dose-reduction strategies in thoracic CT.

    Science.gov (United States)

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Pharmacokinetics of (synthetic) cannabinoids in pigs and their relevance for clinical and forensic toxicology.

    Science.gov (United States)

    Schaefer, Nadine; Wojtyniak, Jan-Georg; Kettner, Mattias; Schlote, Julia; Laschke, Matthias W; Ewald, Andreas H; Lehr, Thorsten; Menger, Michael D; Maurer, Hans H; Schmidt, Peter H

    2016-06-24

    Synthetic cannabinoids (SCs) are gaining increasing importance in clinical and forensic toxicology. They are consumed without any preclinical safety studies. Thus, controlled human pharmacokinetic (PK) studies are not allowed, although being relevant for interpretation of analytical results in cases of misuse or poisoning. As alternative, in a controlled animal experiment, six pigs per drug received a single intravenous dose of 200μg/kg BW each of Δ(9)-tetrahydrocannabinol (THC), 4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone (JWH-210), or 2-(4-methoxyphenyl)-1-(1-pentyl-indol-3-yl)methanone (RCS-4). In addition, six pigs received a combination of the three drugs with the identical dose each. The drugs were determined in serum using LC-MS/MS. A population (pop) PK analysis revealed that a three-compartment model described best the PK data of all three cannabinoids. Central volumes of distribution were estimated at 0.29L/kg, 0.20L/kg, and 0.67L/kg for THC, JWH-210, and RCS-4, respectively. Clearances were 0.042L/min/kg, 0.048L/min/kg, and 0.093L/min/kg for THC, JWH-210, and RCS-4, respectively. The popPK THC pig model was upscaled to humans using allometric techniques. Comparison with published human data revealed that the concentration-time profiles could successfully be predicted. These findings indicate that pigs in conjunction with PK modeling technique may serve as a tool for prediction of human PK of SCs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Manipulating Sensory and Phytochemical Profiles of Greenhouse Tomatoes Using Environmentally Relevant Doses of Ultraviolet Radiation.

    Science.gov (United States)

    Dzakovich, Michael P; Ferruzzi, Mario G; Mitchell, Cary A

    2016-09-14

    Fruits harvested from off-season, greenhouse-grown tomato plants have a poor reputation compared to their in-season, garden-grown counterparts. Presently, there is a gap in knowledge with regard to the role of UV-B radiation (280-315 nm) in determining greenhouse tomato quality. Knowing that UV-B is a powerful elicitor of secondary metabolism and not transmitted through greenhouse glass and some greenhouse plastics, we tested the hypothesis that supplemental UV-B radiation in the greenhouse will impart quality attributes typically associated with garden-grown tomatoes. Environmentally relevant doses of supplemental UV-B radiation did not strongly affect antioxidant compounds of fruits, although the flavonol quercetin-3-O-rutinoside (rutin) significantly increased in response to UV-B. Physicochemical metrics of fruit quality attributes and consumer sensory panels were used to determine if any such differences altered consumer perception of tomato quality. Supplemental UV-A radiation (315-400 nm) pre-harvest treatments enhanced sensory perception of aroma, acidity, and overall approval, suggesting a compelling opportunity to environmentally enhance the flavor of greenhouse-grown tomatoes. The expression of the genes COP1 and HY5 were indicative of adaptation to UV radiation, which explains the lack of marked effects reported in these studies. To our knowledge, these studies represent the first reported use of environmentally relevant doses of UV radiation throughout the reproductive portion of the tomato plant life cycle to positively enhance the sensory and chemical properties of fruits.

  16. Impairment of cocaine-mediated behaviours in mice by clinically relevant Ras-ERK inhibitors

    Science.gov (United States)

    Papale, Alessandro; Morella, Ilaria Maria; Indrigo, Marzia Tina; Bernardi, Rick Eugene; Marrone, Livia; Marchisella, Francesca; Brancale, Andrea; Spanagel, Rainer; Brambilla, Riccardo; Fasano, Stefania

    2016-01-01

    Ras-ERK signalling in the brain plays a central role in drug addiction. However, to date, no clinically relevant inhibitor of this cascade has been tested in experimental models of addiction, a necessary step toward clinical trials. We designed two new cell-penetrating peptides - RB1 and RB3 - that penetrate the brain and, in the micromolar range, inhibit phosphorylation of ERK, histone H3 and S6 ribosomal protein in striatal slices. Furthermore, a screening of small therapeutics currently in clinical trials for cancer therapy revealed PD325901 as a brain-penetrating drug that blocks ERK signalling in the nanomolar range. All three compounds have an inhibitory effect on cocaine-induced ERK activation and reward in mice. In particular, PD325901 persistently blocks cocaine-induced place preference and accelerates extinction following cocaine self-administration. Thus, clinically relevant, systemically administered drugs that attenuate Ras-ERK signalling in the brain may be valuable tools for the treatment of cocaine addiction. DOI: http://dx.doi.org/10.7554/eLife.17111.001 PMID:27557444

  17. Clinical implementation of full Monte Carlo dose calculation in proton beam therapy

    International Nuclear Information System (INIS)

    Paganetti, Harald; Jiang, Hongyu; Parodi, Katia; Slopsema, Roelf; Engelsman, Martijn

    2008-01-01

    The goal of this work was to facilitate the clinical use of Monte Carlo proton dose calculation to support routine treatment planning and delivery. The Monte Carlo code Geant4 was used to simulate the treatment head setup, including a time-dependent simulation of modulator wheels (for broad beam modulation) and magnetic field settings (for beam scanning). Any patient-field-specific setup can be modeled according to the treatment control system of the facility. The code was benchmarked against phantom measurements. Using a simulation of the ionization chamber reading in the treatment head allows the Monte Carlo dose to be specified in absolute units (Gy per ionization chamber reading). Next, the capability of reading CT data information was implemented into the Monte Carlo code to model patient anatomy. To allow time-efficient dose calculation, the standard Geant4 tracking algorithm was modified. Finally, a software link of the Monte Carlo dose engine to the patient database and the commercial planning system was established to allow data exchange, thus completing the implementation of the proton Monte Carlo dose calculation engine ('DoC++'). Monte Carlo re-calculated plans are a valuable tool to revisit decisions in the planning process. Identification of clinically significant differences between Monte Carlo and pencil-beam-based dose calculations may also drive improvements of current pencil-beam methods. As an example, four patients (29 fields in total) with tumors in the head and neck regions were analyzed. Differences between the pencil-beam algorithm and Monte Carlo were identified in particular near the end of range, both due to dose degradation and overall differences in range prediction due to bony anatomy in the beam path. Further, the Monte Carlo reports dose-to-tissue as compared to dose-to-water by the planning system. Our implementation is tailored to a specific Monte Carlo code and the treatment planning system XiO (Computerized Medical Systems Inc

  18. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    OpenAIRE

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.

    2016-01-01

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the d...

  19. Retrospective Dosimetric Comparison of Low-Dose-Rate and Pulsed-Dose-Rate Intracavitary Brachytherapy Using a Tandem and Mini-Ovoids

    International Nuclear Information System (INIS)

    Mourtada, Firas; Gifford, Kent A.; Berner, Paula A.; Horton, John L.; Price, Michael J.; Lawyer, Ann A.; Eifel, Patricia J.

    2007-01-01

    The purpose of this study was to compare the dose distribution of Iridium-192 ( 192 Ir) pulsed-dose-rate (PDR) brachytherapy to that of Cesium-137 ( 137 Cs) low-dose-rate (LDR) brachytherapy around mini-ovoids and an intrauterine tandem. Ten patient treatment plans were selected from our clinical database, all of which used mini-ovoids and an intrauterine tandem. A commercial treatment planning system using AAPM TG43 formalism was used to calculate the dose in water for both the 137 Cs and 192 Ir sources. For equivalent system loadings, we compared the dose distributions in relevant clinical planes, points A and B, and to the ICRU bladder and rectal reference points. The mean PDR doses to points A and B were 3% ± 1% and 6% ± 1% higher than the LDR doses, respectively. For the rectum point, the PDR dose was 4% ± 3% lower than the LDR dose, mainly because of the 192 Ir PDR source anisotropy. For the bladder point, the PDR dose was 1% ± 4% higher than the LDR dose. We conclude that the PDR and LDR dose distributions are equivalent for intracavitary brachytherapy with a tandem and mini-ovoids. These findings will aid in the transfer from the current practice of LDR intracavitary brachytherapy to PDR for the treatment of gynecologic cancers

  20. Increasing clinical relevance in oral radiology: Benefits and challenges when implementing digital assessment.

    Science.gov (United States)

    de Lange, T; Møystad, A; Torgersen, G R

    2018-02-13

    The aims of the study were to investigate benefits and challenges in implementing a digital examination and study the clinical relevance of the digital examination in relation to clinical training and practice. The study was based on semi-structured focus-group interviews from two distinct student populations (2016 and 2017) in a bachelor programme in dental hygiene. In addition, conversational data from a plenary discussion from the whole second student population (2017) were collected and analysed. The data were approached on basis of content analysis. A benefit experienced in the digital examination was the ease in typing and editing answers on the computer. This suggests an increased effectiveness in computer-based compared to analogue examinations. An additional advantage was the experienced relevance of the examination related to the clinic. This finding refers not only to the digital presentations of images, but also to the entire setting in the clinic and dental practice. The limitations reported by the students were non-optimal viewing conditions for presenting radiographic images and difficulties in obtaining an overview of the assignments compared to paper-based examinations due to the linear digital examination format. The last finding on lacking overview revealed an influence on student performances which should be taken seriously in designing digital examinations. In conclusion, the digital layout increases efficiency and clinical relevance of examinations to a certain extent. Obstacles were found in limitations related to image presentation and lack of overview of the examination. The latter challenge raises questions related to developing suitable assessment software. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    Science.gov (United States)

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  2. Islet oxygen consumption rate (OCR) dose predicts insulin independence for first clinical islet allotransplants

    Science.gov (United States)

    Kitzmann, JP; O’Gorman, D; Kin, T; Gruessner, AC; Senior, P; Imes, S; Gruessner, RW; Shapiro, AMJ; Papas, KK

    2014-01-01

    Human islet allotransplant (ITx) for the treatment of type 1 diabetes is in phase III clinical registration trials in the US and standard of care in several other countries. Current islet product release criteria include viability based on cell membrane integrity stains, glucose stimulated insulin release (GSIR), and islet equivalent (IE) dose based on counts. However, only a fraction of patients transplanted with islets that meet or exceed these release criteria become insulin independent following one transplant. Measurements of islet oxygen consumption rate (OCR) have been reported as highly predictive of transplant outcome in many models. In this paper we report on the assessment of clinical islet allograft preparations using islet oxygen consumption rate (OCR) dose (or viable IE dose) and current product release assays in a series of 13 first transplant recipients. The predictive capability of each assay was examined and successful graft function was defined as 100% insulin independence within 45 days post-transplant. Results showed that OCR dose was most predictive of CTO. IE dose was also highly predictive, while GSIR and membrane integrity stains were not. In conclusion, OCR dose can predict CTO with high specificity and sensitivity and is a useful tool for evaluating islet preparations prior to clinical ITx. PMID:25131089

  3. Clinical relevance of and risk factors associated with medication administration time errors

    NARCIS (Netherlands)

    Teunissen, R.; Bos, J.; Pot, H.; Pluim, M.; Kramers, C.

    2013-01-01

    PURPOSE: The clinical relevance of and risk factors associated with errors related to medication administration time were studied. METHODS: In this explorative study, 66 medication administration rounds were studied on two wards (surgery and neurology) of a hospital. Data on medication errors were

  4. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium.

    Science.gov (United States)

    Zifodya, Jackson M; Challens, Cameron H C; Hsieh, Wen-Long

    2016-06-01

    When implementing Acuros XB (AXB) as a substitute for anisotropic analytic algorithm (AAA) in the Eclipse Treatment Planning System, one is faced with a dilemma of reporting either dose to medium, AXB-Dm or dose to water, AXB-Dw. To assist with decision making on selecting either AXB-Dm or AXB-Dw for dose reporting, a retrospective study of treated patients for head & neck (H&N), prostate, breast and lung is presented. Ten patients, previously treated using AAA plans, were selected for each site and re-planned with AXB-Dm and AXB-Dw. Re-planning was done with fixed monitor units (MU) as well as non-fixed MUs. Dose volume histograms (DVH) of targets and organs at risk (OAR), were analyzed in conjunction with ICRU-83 recommended dose reporting metrics. Additionally, comparisons of plan homogeneity indices (HI) and MUs were done to further highlight the differences between the algorithms. Results showed that, on average AAA overestimated dose to the target volume and OARs by less than 2.0 %. Comparisons between AXB-Dw and AXB-Dm, for all sites, also showed overall dose differences to be small (135 % of prescription dose) for target volumes with high density materials. Homogeneity indices showed that AAA planning and optimization templates would need to be adjusted only for the H&N and Lung sites. MU comparison showed insignificant differences between AXB-Dw relative to AAA and between AXB-Dw relative to AXB-Dm. However AXB-Dm MUs relative to AAA, showed an average difference of about 1.3 % signifying an underdosage by AAA. In conclusion, when dose is reported as AXB-Dw, the effect that high density structures in the PTV has on the dose distribution should be carefully considered. As the results show overall small dose differences between the algorithms, when transitioning from AAA to AXB, no significant change to existing prescription protocols is expected. As most of the clinical experience is dose-to-water based and calibration protocols and clinical trials are

  5. Cancer Control Related to Stimulation of Immunity by Low-Dose Radiation

    OpenAIRE

    Liu, Shu-Zheng

    2006-01-01

    Previous studies showed that low dose radiation (LDR) could stimulate the immune system in both animal and human populations. This paper reviews the present status of relevant research as support to the use of LDR in clinical practice for cancer prevention and treatment. It has been demonstrated that radiation-induced changes in immune activity follows an inverse J-shaped curve, i.e., low dose stimulation and high dose suppression. The stimulation of immunity by LDR concerns most anticancer p...

  6. Non-clinical studies in the process of new drug development - Part II: Good laboratory practice, metabolism, pharmacokinetics, safety and dose translation to clinical studies.

    Science.gov (United States)

    Andrade, E L; Bento, A F; Cavalli, J; Oliveira, S K; Schwanke, R C; Siqueira, J M; Freitas, C S; Marcon, R; Calixto, J B

    2016-12-12

    The process of drug development involves non-clinical and clinical studies. Non-clinical studies are conducted using different protocols including animal studies, which mostly follow the Good Laboratory Practice (GLP) regulations. During the early pre-clinical development process, also known as Go/No-Go decision, a drug candidate needs to pass through several steps, such as determination of drug availability (studies on pharmacokinetics), absorption, distribution, metabolism and elimination (ADME) and preliminary studies that aim to investigate the candidate safety including genotoxicity, mutagenicity, safety pharmacology and general toxicology. These preliminary studies generally do not need to comply with GLP regulations. These studies aim at investigating the drug safety to obtain the first information about its tolerability in different systems that are relevant for further decisions. There are, however, other studies that should be performed according to GLP standards and are mandatory for the safe exposure to humans, such as repeated dose toxicity, genotoxicity and safety pharmacology. These studies must be conducted before the Investigational New Drug (IND) application. The package of non-clinical studies should cover all information needed for the safe transposition of drugs from animals to humans, generally based on the non-observed adverse effect level (NOAEL) obtained from general toxicity studies. After IND approval, other GLP experiments for the evaluation of chronic toxicity, reproductive and developmental toxicity, carcinogenicity and genotoxicity, are carried out during the clinical phase of development. However, the necessity of performing such studies depends on the new drug clinical application purpose.

  7. Reporting the results of meta-analyses: a plea for incorporating clinical relevance referring to an example.

    Science.gov (United States)

    Bartels, Ronald H M A; Donk, Roland D; Verhagen, Wim I M; Hosman, Allard J F; Verbeek, André L M

    2017-11-01

    The results of meta-analyses are frequently reported, but understanding and interpreting them is difficult for both clinicians and patients. Statistical significances are presented without referring to values that imply clinical relevance. This study aimed to use the minimal clinically important difference (MCID) to rate the clinical relevance of a meta-analysis. This study is a review of the literature. This study is a review of meta-analyses relating to a specific topic, clinical results of cervical arthroplasty. The outcome measure used in the study was the MCID. We performed an extensive literature search of a series of meta-analyses evaluating a similar subject as an example. We searched in Pubmed and Embase through August 9, 2016, and found articles concerning meta-analyses of the clinical outcome of cervical arthroplasty compared with that of anterior cervical discectomy with fusion in cases of cervical degenerative disease. We evaluated the analyses for statistical significance and their relation to MCID. MCID was defined based on results in similar patient groups and a similar disease entity reported in the literature. We identified 21 meta-analyses, only one of which referred to MCID. However, the researchers used an inappropriate measurement scale and, therefore, an incorrect MCID. The majority of the conclusions were based on statistical results without mentioning clinical relevance. The majority of the articles we reviewed drew conclusions based on statistical differences instead of clinical relevance. We recommend introducing the concept of MCID while reporting the results of a meta-analysis, as well as mentioning the explicit scale of the analyzed measurement. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Radiation-Induced Leukemia at Doses Relevant to Radiation Therapy: Modeling Mechanisms and Estimating Risks

    Science.gov (United States)

    Shuryak, Igor; Sachs, Rainer K.; Hlatky, Lynn; Mark P. Little; Hahnfeldt, Philip; Brenner, David J.

    2006-01-01

    Because many cancer patients are diagnosed earlier and live longer than in the past, second cancers induced by radiation therapy have become a clinically significant issue. An earlier biologically based model that was designed to estimate risks of high-dose radiation induced solid cancers included initiation of stem cells to a premalignant state, inactivation of stem cells at high radiation doses, and proliferation of stem cells during cellular repopulation after inactivation. This earlier model predicted the risks of solid tumors induced by radiation therapy but overestimated the corresponding leukemia risks. Methods: To extend the model to radiation-induced leukemias, we analyzed in addition to cellular initiation, inactivation, and proliferation a repopulation mechanism specific to the hematopoietic system: long-range migration through the blood stream of hematopoietic stem cells (HSCs) from distant locations. Parameters for the model were derived from HSC biologic data in the literature and from leukemia risks among atomic bomb survivors v^ ho were subjected to much lower radiation doses. Results: Proliferating HSCs that migrate from sites distant from the high-dose region include few preleukemic HSCs, thus decreasing the high-dose leukemia risk. The extended model for leukemia provides risk estimates that are consistent with epidemiologic data for leukemia risk associated with radiation therapy over a wide dose range. For example, when applied to an earlier case-control study of 110000 women undergoing radiotherapy for uterine cancer, the model predicted an excess relative risk (ERR) of 1.9 for leukemia among women who received a large inhomogeneous fractionated external beam dose to the bone marrow (mean = 14.9 Gy), consistent with the measured ERR (2.0, 95% confidence interval [CI] = 0.2 to 6.4; from 3.6 cases expected and 11 cases observed). As a corresponding example for brachytherapy, the predicted ERR of 0.80 among women who received an inhomogeneous low-dose

  9. A Vietnamese man with selective mutism: the relevance of multiple interacting 'cultures' in clinical psychiatry.

    Science.gov (United States)

    Hollifield, Michael; Geppert, Cynthia; Johnson, Yuam; Fryer, Carol

    2003-09-01

    Multiple cultural variables have effects on the psychobiology and behavioral manifestations of illness, as do patient and physician perceptions of illness. The interaction among these variables is at the heart of clinical psychiatry. This case of a Vietnamese man with selective mutism underscores the relevance of the 'cultures' of medicine, psychiatry, and war and trauma on the manifestations of illness and illness perceptions by patient and physician. The discussion focuses on how these cultures interact and play a crucial role in formulating diagnosis and treatment planning. Suggestions are given for shifts in medical education that will encourage relevant cultural paradigms to make their way into educational and clinical systems, which in turn should improve cultural competence in clinical psychiatry.

  10. Combination Therapy with Zoledronic Acid and Parathyroid Hormone Improves Bone Architecture and Strength following a Clinically-Relevant Dose of Stereotactic Radiation Therapy for the Local Treatment of Canine Osteosarcoma in Athymic Rats.

    Science.gov (United States)

    Curtis, Ryan C; Custis, James T; Ehrhart, Nicole P; Ehrhart, E J; Condon, Keith W; Gookin, Sara E; Donahue, Seth W

    2016-01-01

    Clinical studies using definitive-intent stereotactic radiation therapy (SRT) for the local treatment of canine osteosarcoma (OSA) have shown canine patients achieving similar median survival times as the current standard of care (amputation and adjuvant chemotherapy). Despite this, there remains an unacceptable high risk of pathologic fracture following radiation treatment. Zoledronic acid (ZA) and parathyroid hormone (PTH) are therapeutic candidates for decreasing this fracture risk post-irradiation. Due to differing mechanisms, we hypothesized that the combined treatment with ZA and PTH would significantly improve bone healing more than ZA or PTH treatment alone. Using an orthotopic model of canine osteosarcoma in athymic rats, we evaluated bone healing following clinically-relevant doses of radiation therapy (12 Gy x 3 fractions, 36 Gy total). Groups included 36 Gy SRT only, 36 Gy SRT plus ZA, 36 Gy SRT plus ZA and PTH, 36 Gy SRT plus PTH, and 36 Gy SRT plus localized PTH treatment. Our study showed significant increases in bone volume and increased polar moments of inertia (in the distal femoral metaphysis) 8 weeks after radiation in the combined (ZA/PTH) treatment group as compared to radiation treatment alone. Histomorphometric analysis revealed evidence of active mineralization at the study endpoint as well as successful tumor-cell kill across all treatment groups. This work provides further evidence for the expanding potential indications for ZA and PTH therapy, including post-irradiated bone disease due to osteosarcoma.

  11. Combination Therapy with Zoledronic Acid and Parathyroid Hormone Improves Bone Architecture and Strength following a Clinically-Relevant Dose of Stereotactic Radiation Therapy for the Local Treatment of Canine Osteosarcoma in Athymic Rats.

    Directory of Open Access Journals (Sweden)

    Ryan C Curtis

    Full Text Available Clinical studies using definitive-intent stereotactic radiation therapy (SRT for the local treatment of canine osteosarcoma (OSA have shown canine patients achieving similar median survival times as the current standard of care (amputation and adjuvant chemotherapy. Despite this, there remains an unacceptable high risk of pathologic fracture following radiation treatment. Zoledronic acid (ZA and parathyroid hormone (PTH are therapeutic candidates for decreasing this fracture risk post-irradiation. Due to differing mechanisms, we hypothesized that the combined treatment with ZA and PTH would significantly improve bone healing more than ZA or PTH treatment alone. Using an orthotopic model of canine osteosarcoma in athymic rats, we evaluated bone healing following clinically-relevant doses of radiation therapy (12 Gy x 3 fractions, 36 Gy total. Groups included 36 Gy SRT only, 36 Gy SRT plus ZA, 36 Gy SRT plus ZA and PTH, 36 Gy SRT plus PTH, and 36 Gy SRT plus localized PTH treatment. Our study showed significant increases in bone volume and increased polar moments of inertia (in the distal femoral metaphysis 8 weeks after radiation in the combined (ZA/PTH treatment group as compared to radiation treatment alone. Histomorphometric analysis revealed evidence of active mineralization at the study endpoint as well as successful tumor-cell kill across all treatment groups. This work provides further evidence for the expanding potential indications for ZA and PTH therapy, including post-irradiated bone disease due to osteosarcoma.

  12. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium

    International Nuclear Information System (INIS)

    Zifoyda, Jackson M.; Challens, Cameron H.C.; Hsieh, Wen-Long

    2016-01-01

    from AAA to AXB, no significant change to existing prescription protocols is expected. As most of the clinical experience is dose-to-water based and calibration protocols and clinical trials are also dose-to-water based and there still exists uncertainties in converting CT number to medium, selecting AXB-Dw is strongly recommended.

  13. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  14. Clinically Relevant Physical Benefits of Exercise Interventions in Breast Cancer Survivors.

    Science.gov (United States)

    Kirkham, Amy A; Bland, Kelcey A; Sayyari, Sarah; Campbell, Kristin L; Davis, Margot K

    2016-02-01

    Evidence is currently limited for the effect of exercise on breast cancer clinical outcomes. However, several of the reported physical benefits of exercise, including peak oxygen consumption, functional capacity, muscle strength and lean mass, cardiovascular risk factors, and bone health, have established associations with disability, cardiovascular disease risk, morbidity, and mortality. This review will summarize the clinically relevant physical benefits of exercise interventions in breast cancer survivors and discuss recommendations for achieving these benefits. It will also describe potential differences in intervention delivery that may impact outcomes and, lastly, describe current physical activity guidelines for cancer survivors.

  15. Reformulation of a clinical-dose system for carbon-ion radiotherapy treatment planning at the National Institute of Radiological Sciences, Japan

    Science.gov (United States)

    Inaniwa, Taku; Kanematsu, Nobuyuki; Matsufuji, Naruhiro; Kanai, Tatsuaki; Shirai, Toshiyuki; Noda, Koji; Tsuji, Hiroshi; Kamada, Tadashi; Tsujii, Hirohiko

    2015-04-01

    At the National Institute of Radiological Sciences (NIRS), more than 8,000 patients have been treated for various tumors with carbon-ion (C-ion) radiotherapy in the past 20 years based on a radiobiologically defined clinical-dose system. Through clinical experience, including extensive dose escalation studies, optimum dose-fractionation protocols have been established for respective tumors, which may be considered as the standards in C-ion radiotherapy. Although the therapeutic appropriateness of the clinical-dose system has been widely demonstrated by clinical results, the system incorporates several oversimplifications such as dose-independent relative biological effectiveness (RBE), empirical nuclear fragmentation model, and use of dose-averaged linear energy transfer to represent the spectrum of particles. We took the opportunity to update the clinical-dose system at the time we started clinical treatment with pencil beam scanning, a new beam delivery method, in 2011. The requirements for the updated system were to correct the oversimplifications made in the original system, while harmonizing with the original system to maintain the established dose-fractionation protocols. In the updated system, the radiation quality of the therapeutic C-ion beam was derived with Monte Carlo simulations, and its biological effectiveness was predicted with a theoretical model. We selected the most used C-ion beam with αr = 0.764 Gy-1 and β = 0.0615 Gy-2 as reference radiation for RBE. The C-equivalent biological dose distribution is designed to allow the prescribed survival of tumor cells of the human salivary gland (HSG) in entire spread-out Bragg peak (SOBP) region, with consideration to the dose dependence of the RBE. This C-equivalent biological dose distribution is scaled to a clinical dose distribution to harmonize with our clinical experiences with C-ion radiotherapy. Treatment plans were made with the original and the updated clinical-dose systems, and both

  16. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, Wolfgang [Multiorgan Screening Foundation, Frankfurt (Germany); University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany); University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg [University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Wiedemann, Baerbel [University Hospital Dresden, Institute of Medical Informatics and Biometrics, Dresden (Germany); Wehrmann, Ursula [University Hospital Dresden, Clinic and Policlinic of Surgery, Dresden (Germany); Koch, Arne; Abolmaali, Nasreddin [University Hospital Dresden, Oncoray, Dresden (Germany); Toussaint, Todd; Luboldt, Hans-Joachim [Multiorgan Screening Foundation, Frankfurt (Germany); Middendorp, Markus; Gruenwald, Frank [University Hospital Frankfurt, Department of Nuclear Medicine, Frankfurt (Germany); Aust, Daniela [University Hospital Dresden, Department of Pathology, Dresden (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany)

    2010-09-15

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas {>=}10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV{sub max} was {>=}5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV{sub max}. FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV{sub max}{>=} 5 improves the accuracy. (orig.)

  17. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg; Wiedemann, Baerbel; Wehrmann, Ursula; Koch, Arne; Abolmaali, Nasreddin; Toussaint, Todd; Luboldt, Hans-Joachim; Middendorp, Markus; Gruenwald, Frank; Aust, Daniela; Vogl, Thomas J.

    2010-01-01

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas ≥10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV max was ≥5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV max . FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV max ≥ 5 improves the accuracy. (orig.)

  18. [Academic discussion of adverse reaction of clinical trials of new traditional Chinese medicines and relevant influencing factors].

    Science.gov (United States)

    Wang, Wen-ping; Yu, Ming; Wang, Li; Jiang, Xi-ren; Li, Xiao-bin; Wang, Hua-wei; Cao, Ying; Liu, Kai; Huang, Lu-qi

    2015-01-01

    Data of clinical trial projects involved by clinical trial institutions certified by the State Food and Drug Administration from 2002 to November 2012 were collected to summarize adverse reactions in project summary/statistical reports, analyze the rate of adverse reactions of clinical trials of new traditional Chinese medicines and relevant influencing factors, and increase the awareness of the safety of new traditional Chinese medicines. A total of 73 050 cases in 209 projects of 14 specialties were collected, including 49 689 cases in the new traditional Chinese medicine group and 271 adverse reaction cases, with an incidence rate of adverse reactions at 0.55%. The adverse reaction rate in 3 months 0.63% for injection > 0.50% for oral. In the administration of only the test drug, the adverse reaction rate of patches was the highest (2.68%), whereas that of aerosols and suppositories was lowest (0). In the combined administration of the test drug and the simulation agent, the adverse reaction rate of external test patch + capsule was the highest (3.38%), whereas that of capsule + oral liquid, pills + granules, tablets + oral liquid, tablets + pills, tablet + capsule was the lowest (0). In the administration of only the test drug, the adverse reaction rate was 0.47%; In the combined administration with simulation agent (drug volume increase), the adverse reaction rate was 0.74%. Different doses caused adverse reaction different rates; The adverse reaction rate of drugs with whole-course dose between 1 100-1 200 g was the highest (3.36%), that for whole-course doses of 500-600, 900-1 000, 1 400-1 500, 1 600-1 700, 1 800-1 900 g was the lowest (0). In conclusion, the adverse reaction rate of new traditional Chinese medicines was still up to 0.55%, with the adverse reaction rate between 0.47% and 0.72% over the 11 years, without significant difference in each year. The adverse reaction rate was closely related to course of treatment, approach of administration

  19. Interpretation of the margin of exposure for genotoxic carcinogens - elicitation of expert knowledge about the form of the dose response curve at human relevant exposures.

    Science.gov (United States)

    Boobis, Alan; Flari, Villie; Gosling, John Paul; Hart, Andy; Craig, Peter; Rushton, Lesley; Idahosa-Taylor, Ehi

    2013-07-01

    The general approach to risk assessment of genotoxic carcinogens has been to advise reduction of exposure to "as low as reasonably achievable/practicable" (ALARA/P). However, whilst this remains the preferred risk management option, it does not provide guidance on the urgency or extent of risk management actions necessary. To address this, the "Margin of Exposure" (MOE) approach has been proposed. The MOE is the ratio between the point of departure for carcinogenesis and estimated human exposure. However, interpretation of the MOE requires implicit or explicit consideration of the shape of the dose-response curve at human relevant exposures. In a structured elicitation exercise, we captured expert opinion on available scientific evidence for low dose-response relationships for genotoxic carcinogens. This allowed assessment of: available evidence for the nature of dose-response relationships at human relevant exposures; the generality of judgments about such dose-response relationships; uncertainties affecting judgments on the nature of such dose-response relationships; and whether this last should differ for different classes of genotoxic carcinogens. Elicitation results reflected the variability in experts' views on the form of the dose-response curve for low dose exposure and major sources of uncertainty affecting the assumption of a linear relationship. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Free software to analyse the clinical relevance of drug interactions with antiretroviral agents (SIMARV®) in patients with HIV/AIDS.

    Science.gov (United States)

    Giraldo, N A; Amariles, P; Monsalve, M; Faus, M J

    Highly active antiretroviral therapy has extended the expected lifespan of patients with HIV/AIDS. However, the therapeutic benefits of some drugs used simultaneously with highly active antiretroviral therapy may be adversely affected by drug interactions. The goal was to design and develop a free software to facilitate analysis, assessment, and clinical decision making according to the clinical relevance of drug interactions in patients with HIV/AIDS. A comprehensive Medline/PubMed database search of drug interactions was performed. Articles that recognized any drug interactions in HIV disease were selected. The publications accessed were limited to human studies in English or Spanish, with full texts retrieved. Drug interactions were analyzed, assessed, and grouped into four levels of clinical relevance according to gravity and probability. Software to systematize the information regarding drug interactions and their clinical relevance was designed and developed. Overall, 952 different references were retrieved and 446 selected; in addition, 67 articles were selected from the citation lists of identified articles. A total of 2119 pairs of drug interactions were identified; of this group, 2006 (94.7%) were drug-drug interactions, 1982 (93.5%) had an identified pharmacokinetic mechanism, and 1409 (66.5%) were mediated by enzyme inhibition. In terms of clinical relevance, 1285 (60.6%) drug interactions were clinically significant in patients with HIV (levels 1 and 2). With this information, a software program that facilitates identification and assessment of the clinical relevance of antiretroviral drug interactions (SIMARV ® ) was developed. A free software package with information on 2119 pairs of antiretroviral drug interactions was designed and developed that could facilitate analysis, assessment, and clinical decision making according to the clinical relevance of drug interactions in patients with HIV/AIDS. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Clinical dosimetry with plastic scintillators - Almost energy independent, direct absorbed dose reading with high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Fluehs, D [Department of Radiotherapy, Essen (Germany). Div. of Clinical Radiation Physics; Fluehs, D; Kolanoski, H [Dortmund Univ. (Germany). Inst. fuer Physik

    1996-08-01

    Clinical dosimetry is still far behind the goal to measure any spatial or temporal distribution of absorbed dose fast and precise without disturbing the physical situation by the dosimetry procedure. NE 102A plastic scintillators overcome this border. These tissue substituting dosemeter probes open a wide range of new clinical applications of dosimetry. This versatile new dosimetry system enables fast measurement of the absorbed dose to water in water also in regions with a steep dose gradient, close to interfaces, or in partly shielded regions. It allows direct reading dosimetry in the energy range of all clinically used external photon and electron beams, or around all branchytherapy sources. Thin detector arrays permit fast and high resolution measurements in quality assurance, such as in-vivo dosimetry or even afterloading dose monitoring. A main field of application is the dosimetric treatment planning, the individual optimization of brachytherapy applicators. Thus, plastic scintillator dosemeters cover optimally all difficult fields of clinical dosimetry. An overview about its characteristics and applications is given here. 20 refs, 1 fig.

  2. Strategic characterization of anti-drug antibody responses for the assessment of clinical relevance and impact.

    Science.gov (United States)

    Tatarewicz, Suzanna M; Mytych, Daniel T; Manning, Marta Starcevic; Swanson, Steven J; Moxness, Michael S; Chirmule, Narendra

    2014-06-01

    All therapeutic proteins have the potential to induce anti-drug antibodies (ADA). Clinically relevant ADA can impact efficacy and/or safety of a biological therapeutic. Immunogenicity assessment strategy evaluates binding and neutralizing ADA, and the need for additional characterization (e.g., epitope, titer and so on) is determined using a risk-based approach. The choice of characterization assays depends on the type, application and immunogenicity of the therapeutic. ADA characterization can impact the interpretation of the risk profile of a given therapeutic, and offers insight into opportunities for risk mitigation and management. This article describes common ADA characterization methods. Strategic assessment and characterization of clinically relevant ADA are discussed, in order to support clinical options for safe and effective patient care and disease management.

  3. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  4. Detection of base damage in DNA in human blood exposed to ionizing radiation at biologically relevant doses

    International Nuclear Information System (INIS)

    Loon, A.A.W.M. van; Lohman, P.H.M.; Groenendijk, R.H.; Schans, G.P. van der; Baan, R.A.

    1991-01-01

    The alkaline elution technique for the detection of DNA damage has been adapted to allow application on unlabelled blood cells. Both the induction and subsequent repair have been studied of two classes of DNA damage, viz. single-strand breaks and base damage recognized by the γ-endonuclease activity in a cell-free extract of Micrococcus luteus bacteria. The high sensitivity of the assay permitted the measurement of induction and repair of base damage after in vitro exposure of full blood under aerobic conditions to biologically relevant doses of γ-rays (1.5-4.5 Gy). After a radiation dose of 3 Gy about 50% of the base damage was removed within 1.5 h of repair. Base damage could still be detected at 24h after exposure to 15 Gy. (author)

  5. Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry.

    Science.gov (United States)

    Liu, Derek; Sloboda, Ron S

    2014-05-01

    Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

  6. Measuring agreement between rating interpretations and binary clinical interpretations of images: a simulation study of methods for quantifying the clinical relevance of an observer performance paradigm

    International Nuclear Information System (INIS)

    Chakraborty, Dev P

    2012-01-01

    Laboratory receiver operating characteristic (ROC) studies, that are often used to evaluate medical imaging systems, differ from ‘live’ clinical interpretations in several respects which could compromise their clinical relevance. The aim was to develop methodology for quantifying the clinical relevance of a laboratory ROC study. A simulator was developed to generate ROC ratings data and binary clinical interpretations classified as correct or incorrect for a common set of images interpreted under clinical and laboratory conditions. The area under the trapezoidal ROC curve (AUC) was used as the laboratory figure-of-merit and the fraction of correct clinical decisions as the clinical figure-of-merit. Conventional agreement measures (Pearson, Spearman, Kendall and kappa) between the bootstrap-induced fluctuations of the two figures of merit were estimated. A jackknife pseudovalue transformation applied to the figures of merit was also investigated as a way to capture agreement existing at the individual image level that could be lost at the figure-of-merit level. It is shown that the pseudovalues define a relevance-ROC curve. The area under this curve (rAUC) measures the ability of the laboratory figure-of-merit-based pseudovalues to correctly classify incorrect versus correct clinical interpretations. Therefore, rAUC is a measure of the clinical relevance of an ROC study. The conventional measures and rAUC were compared under varying simulator conditions. It was found that design details of the ROC study, namely the number of bins, the difficulty level of the images, the ratio of disease-present to disease-absent images and the unavoidable difference between laboratory and clinical performance levels, can lead to serious underestimation of the agreement as indicated by conventional agreement measures, even for perfectly correlated data, while rAUC showed high agreement and was relatively immune to these details. At the same time rAUC was sensitive to factors such

  7. Reformulation of a clinical-dose system for carbon-ion radiotherapy treatment planning at the National Institute of Radiological Sciences, Japan

    International Nuclear Information System (INIS)

    Inaniwa, Taku; Kanematsu, Nobuyuki; Matsufuji, Naruhiro; Shirai, Toshiyuki; Noda, Koji; Kanai, Tatsuaki; Tsuji, Hiroshi; Kamada, Tadashi; Tsujii, Hirohiko

    2015-01-01

    At the National Institute of Radiological Sciences (NIRS), more than 8,000 patients have been treated for various tumors with carbon-ion (C-ion) radiotherapy in the past 20 years based on a radiobiologically defined clinical-dose system. Through clinical experience, including extensive dose escalation studies, optimum dose-fractionation protocols have been established for respective tumors, which may be considered as the standards in C-ion radiotherapy. Although the therapeutic appropriateness of the clinical-dose system has been widely demonstrated by clinical results, the system incorporates several oversimplifications such as dose-independent relative biological effectiveness (RBE), empirical nuclear fragmentation model, and use of dose-averaged linear energy transfer to represent the spectrum of particles. We took the opportunity to update the clinical-dose system at the time we started clinical treatment with pencil beam scanning, a new beam delivery method, in 2011. The requirements for the updated system were to correct the oversimplifications made in the original system, while harmonizing with the original system to maintain the established dose-fractionation protocols. In the updated system, the radiation quality of the therapeutic C-ion beam was derived with Monte Carlo simulations, and its biological effectiveness was predicted with a theoretical model. We selected the most used C-ion beam with α r = 0.764 Gy −1 and β = 0.0615 Gy −2 as reference radiation for RBE. The C-equivalent biological dose distribution is designed to allow the prescribed survival of tumor cells of the human salivary gland (HSG) in entire spread-out Bragg peak (SOBP) region, with consideration to the dose dependence of the RBE. This C-equivalent biological dose distribution is scaled to a clinical dose distribution to harmonize with our clinical experiences with C-ion radiotherapy. Treatment plans were made with the original and the updated clinical-dose systems, and both

  8. Single dose (400 mg) versus 7 day (200 mg) daily dose itraconazole in the treatment of tinea versicolor: a randomized clinical trial.

    Science.gov (United States)

    Wahab, M A; Ali, M E; Rahman, M H; Chowdhury, S A; Monamie, N S; Sultana, N; Khondoker, L

    2010-01-01

    Tinea (pityriasis) versicolor is a superficial fungal infection and one of the most commonly found pigmentary disorders of skin caused by the yeast Malassezia. Multiple topical as well as systemic therapies are available for treatment. Systemic therapies are used for extensive disease, frequent relapse or where topical agents have failed. The aim that translates the rationale of the study was to compare the efficacy, safety, tolerability and cost effectiveness of single dose 400mg versus 7 day 200 mg daily dose of itraconazole in the treatment of tinea versicolor. A clinical study was done to compare the efficacy of single dose (400 mg) of itraconazole and 7 day 200 mg daily dose of itraconazole in the treatment of extensive tinea versicolor. Total 60 patients (aged 18-50 years) were selected for the study during the period of June 2007 to May 2008 in the department of Dermatology of three different hospitals in Bangladesh. Cases having with extensive involvement, diagnosed clinically and confirmed by wood's lamp and KOH microscopy were taken. Patients were randomly allocated into equal groups. Group A was given single dose 400 mg itraconazole and Group B was given 7 day 200 mg daily itraconazole. Fifty three (88%) male and 7(12%) female were included in the study. The mean age of group A was 32.37+/-9 years and in group B 33.23+/-8 years. The mean duration of the disease in group A was 2.63+/-2 months and 2.76+/-2 months in group B. In group A clinical responders was found cure 22(73.33%) and improvement 5(16.33%) and in group B it was found cure 24(79.99%) and improvement 4(13.33%). The measure at the End point (EP1) equals to 90% response and in-group B it was found cure 24 (79.99%) and improvement 4(13.33%). (Here the End point EP2) equals to 93.33%. The EP clinical analysis however shows 91.66% response. Both single dose and 7 day daily dose of itraconazole can be effective in the treatment of tinea versicolor with extensive involvement but single dose appears

  9. Development of CER-001: Preclinical Dose Selection Through to Phase I Clinical Findings.

    Science.gov (United States)

    Keyserling, Constance H; Barbaras, Ronald; Benghozi, Renee; Dasseux, Jean-Louis

    2017-05-01

    CER-001 comprises recombinant human apolipoprotein A-I complexed with phospholipids that mimics natural, nascent, pre-β high-density lipoprotein (HDL). We present animal model data showing dose-dependent increases in cholesterol efflux with CER-001 and its subsequent elimination by reverse lipid transport, together with inhibition of atherosclerotic plaque progression. We report the first phase I study results with CER-001 in humans, starting at 0.25 mg/kg, which is 1/80th of the safe dose (20 mg/kg) established in 4-week multiple-dose animal studies dosed every second day. Healthy volunteers, 18-55 years old with a low-density lipoprotein-cholesterol:HDL-cholesterol ratio greater than 3.0, received single intravenous escalating doses of CER-001 (0.25-45.0 mg/kg) and placebo in a double-blind randomised cross-over fashion. Subjects were followed up for 3 weeks post-dose. Assessments included adverse event monitoring, blood sampling, and clinical laboratory measurements. Thirty-two subjects were enrolled. All CER-001 doses (0.25-45 mg/kg) were safe and well tolerated, with an adverse event profile similar to placebo. Effects on clinical chemistry, haematology and coagulation parameters were comparable to placebo. No adverse effects of CER-001 on electrocardiograms were observed. No antibodies to apolipoprotein A-I were detected following single-dose administration of CER-001. Plasma apolipoprotein A-I levels increased in a dose-related manner and returned to baseline by 24 h post-dose for doses up to 10 mg/kg but remained in circulation for >72 h post-dose for doses >10 mg/kg. CER-001 caused elevations in plasma cholesterol and total and unesterified cholesterol in the HDL fraction. Mobilisation of unesterified cholesterol in the HDL fraction was seen with CER-001 at doses as low as 2 mg/kg. CER-001 is well tolerated when administered to humans as single doses up to 45 mg/kg and mobilises and eliminates cholesterol via reverse lipid transport.

  10. Radiation dose responses for chemoradiation therapy of pancreatic cancer: an analysis of compiled clinical data using biophysical models.

    Science.gov (United States)

    Moraru, Ion C; Tai, An; Erickson, Beth; Li, X Allen

    2014-01-01

    We analyzed recent clinical data obtained from chemoradiation of unresectable, locally advanced pancreatic cancer (LAPC) in order to examine possible benefits from radiation therapy dose escalation. A modified linear quadratic model was used to fit clinical tumor response and survival data of chemoradiation treatments for LAPC reported from 20 institutions. Biophysical radiosensitivity parameters were extracted from the fits. Examination of the clinical data demonstrated an enhancement in tumor response with higher irradiation dose, an important clinical result for palliation and quality of life. Little indication of improvement in 1-year survival with increased radiation dose was observed. Possible dose escalation schemes are proposed based on calculations of the biologically effective dose required for a 50% tumor response rate. Based on the evaluation of tumor response data, the escalation of radiation dose presents potential clinical benefits which when combined with normal tissue complication analyses may result in improved treatment outcome for locally advanced pancreatic cancer patients. Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  11. Identifying clinically relevant drug resistance genes in drug-induced resistant cancer cell lines and post-chemotherapy tissues.

    Science.gov (United States)

    Tong, Mengsha; Zheng, Weicheng; Lu, Xingrong; Ao, Lu; Li, Xiangyu; Guan, Qingzhou; Cai, Hao; Li, Mengyao; Yan, Haidan; Guo, You; Chi, Pan; Guo, Zheng

    2015-12-01

    Until recently, few molecular signatures of drug resistance identified in drug-induced resistant cancer cell models can be translated into clinical practice. Here, we defined differentially expressed genes (DEGs) between pre-chemotherapy colorectal cancer (CRC) tissue samples of non-responders and responders for 5-fluorouracil and oxaliplatin-based therapy as clinically relevant drug resistance genes (CRG5-FU/L-OHP). Taking CRG5-FU/L-OHP as reference, we evaluated the clinical relevance of several types of genes derived from HCT116 CRC cells with resistance to 5-fluorouracil and oxaliplatin, respectively. The results revealed that DEGs between parental and resistant cells, when both were treated with the corresponding drug for a certain time, were significantly consistent with the CRG5-FU/L-OHP as well as the DEGs between the post-chemotherapy CRC specimens of responders and non-responders. This study suggests a novel strategy to extract clinically relevant drug resistance genes from both drug-induced resistant cell models and post-chemotherapy cancer tissue specimens.

  12. Hypersensitivities for acetaldehyde and other agents among cancer cells null for clinically relevant Fanconi anemia genes.

    Science.gov (United States)

    Ghosh, Soma; Sur, Surojit; Yerram, Sashidhar R; Rago, Carlo; Bhunia, Anil K; Hossain, M Zulfiquer; Paun, Bogdan C; Ren, Yunzhao R; Iacobuzio-Donahue, Christine A; Azad, Nilofer A; Kern, Scott E

    2014-01-01

    Large-magnitude numerical distinctions (>10-fold) among drug responses of genetically contrasting cancers were crucial for guiding the development of some targeted therapies. Similar strategies brought epidemiological clues and prevention goals for genetic diseases. Such numerical guides, however, were incomplete or low magnitude for Fanconi anemia pathway (FANC) gene mutations relevant to cancer in FANC-mutation carriers (heterozygotes). We generated a four-gene FANC-null cancer panel, including the engineering of new PALB2/FANCN-null cancer cells by homologous recombination. A characteristic matching of FANCC-null, FANCG-null, BRCA2/FANCD1-null, and PALB2/FANCN-null phenotypes was confirmed by uniform tumor regression on single-dose cross-linker therapy in mice and by shared chemical hypersensitivities to various inter-strand cross-linking agents and γ-radiation in vitro. Some compounds, however, had contrasting magnitudes of sensitivity; a strikingly high (19- to 22-fold) hypersensitivity was seen among PALB2-null and BRCA2-null cells for the ethanol metabolite, acetaldehyde, associated with widespread chromosomal breakage at a concentration not producing breaks in parental cells. Because FANC-defective cancer cells can share or differ in their chemical sensitivities, patterns of selective hypersensitivity hold implications for the evolutionary understanding of this pathway. Clinical decisions for cancer-relevant prevention and management of FANC-mutation carriers could be modified by expanded studies of high-magnitude sensitivities. Copyright © 2014 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  13. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting

    DEFF Research Database (Denmark)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor

    2017-01-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal...... and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft...... enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat...

  14. MDMA, methamphetamine, and CYP2D6 pharmacogenetics: what is clinically relevant?

    Directory of Open Access Journals (Sweden)

    Rafael eDe La Torre

    2012-11-01

    Full Text Available In vitro human studies show that the metabolism of most amphetamine-like psychostimulants is regulated by the polymorphic cytochrome P450 isozyme CYP2D6. Two compounds, methamphetamine and 3,4-methylenedioxymethamphetamine (MDMA, were selected as archetypes to discuss the translation and clinical significance of in vitro to in vivo findings. Both compounds were chosen based on their differential interaction with CYP2D6 and their high abuse prevalence in society. Methamphetamine behaves as both a weak substrate and competitive inhibitor of CYP2D6, while MDMA acts as a high affinity substrate and potent mechanism-based inhibitor (MBI of the enzyme. The MBI behavior of MDMA on CYP2D6 implies that subjects, irrespective of their genotype/phenotype, are phenocopied to the poor metabolizer phenotype. The fraction of metabolic clearance regulated by CYP2D6 for both drugs is substantially lower than expected from in vitro studies. Other isoenzymes of cytochrome P450 and a relevant contribution of renal excretion play a part in their clearance. These facts tune down the potential contribution of CYP2D6 polymorphism in the clinical outcomes of both substances. Globally, the clinical relevance of CYP2D6 polymorphism is lower than that predicted by in vitro studies.

  15. Dissociative absorption: An empirically unique, clinically relevant, dissociative factor.

    Science.gov (United States)

    Soffer-Dudek, Nirit; Lassri, Dana; Soffer-Dudek, Nir; Shahar, Golan

    2015-11-01

    Research of dissociative absorption has raised two questions: (a) Is absorption a unique dissociative factor within a three-factor structure, or a part of one general dissociative factor? Even when three factors are found, the specificity of the absorption factor is questionable. (b) Is absorption implicated in psychopathology? Although commonly viewed as "non-clinical" dissociation, absorption was recently hypothesized to be specifically associated with obsessive-compulsive symptoms. To address these questions, we conducted exploratory and confirmatory factor analyses on 679 undergraduates. Analyses supported the three-factor model, and a "purified" absorption scale was extracted from the original inclusive absorption factor. The purified scale predicted several psychopathology scales. As hypothesized, absorption was a stronger predictor of obsessive-compulsive symptoms than of general psychopathology. In addition, absorption was the only dissociative scale that longitudinally predicted obsessive-compulsive symptoms. We conclude that absorption is a unique and clinically relevant dissociative tendency that is particularly meaningful to obsessive-compulsive symptoms. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Clinical relevance of routinely measured vital signs in hospitalized patients: a systematic review

    NARCIS (Netherlands)

    Storm-Versloot, Marja N.; Verweij, Lotte; Lucas, Cees; Ludikhuize, Jeroen; Goslings, J. Carel; Legemate, Dink A.; Vermeulen, Hester

    2014-01-01

    Conflicting evidence exists on the effectiveness of routinely measured vital signs on the early detection of increased probability of adverse events. To assess the clinical relevance of routinely measured vital signs in medically and surgically hospitalized patients through a systematic review.

  17. ICRU reference dose in an era of intensity-modulated radiation therapy clinical trials: Correlation with planning target volume mean dose and suitability for intensity-modulated radiation therapy dose prescription

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Hong, Linda; Mah, Dennis; Shen Jin; Mutyala, Subhakar; Spierer, Marnee; Garg, Madhur; Guha, Chandan; Kalnicki, Shalom

    2008-01-01

    Background and Purpose: IMRT clinical trials lack dose prescription and specification standards similar to ICRU standards for two- and three-dimensional external beam planning. In this study, we analyzed dose distributions for patients whose treatment plans incorporated IMRT, and compared the dose determined at the ICRU reference point to the PTV doses determined from dose-volume histograms. Additionally, we evaluated if ICRU reference type single-point dose prescriptions are suitable for IMRT dose prescriptions. Materials and methods: For this study, IMRT plans of 117 patients treated at our institution were randomly selected and analyzed. The treatment plans were clinically applied to the following disease sites: abdominal (11), anal (10), brain (11), gynecological (15), head and neck (25), lung (15), male pelvis (10) and prostate (20). The ICRU reference point was located in each treatment plan following ICRU Report 50 guidelines. The reference point was placed in the central part of the PTV and at or near the isocenter. In each case, the dose was calculated and recorded to this point. For each patient - volume and dose (PTV, PTV mean, median and modal) information was extracted from the planned dose-volume histogram. Results: The ICRU reference dose vs PTV mean dose relationship in IMRT exhibited a weak positive association (Pearson correlation coefficient 0.63). In approximately 65% of the cases studied, dose at the ICRU reference point was greater than the corresponding PTV mean dose. The dose difference between ICRU reference and PTV mean doses was ≤2% in approximately 79% of the cases studied (average 1.21% (±1.55), range -4% to +4%). Paired t-test analyses showed that the ICRU reference doses and PTV median doses were statistically similar (p = 0.42). The magnitude of PTV did not influence the difference between ICRU reference and PTV mean doses. Conclusions: The general relationship between ICRU reference and PTV mean doses in IMRT is similar to that

  18. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting: A Systematic Review.

    Science.gov (United States)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor; Herly, Mikkel; Trojahn Kølle, Stig-Frederik; Fischer-Nielsen, Anne; Drzewiecki, Krzysztof Tadeusz

    2017-07-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat grafting. Improvements in graft retention, the SVF to fat (SVF:fat) ratio, and the ASC concentration used for enrichment were emphasized. We proposed an increased retention rate greater than 1.5-fold relative to nonenriched grafts and a maximum SVF:fat ratio of 1:1 as the thresholds for clinical relevance and feasibility, respectively. Nine studies fulfilled these criteria, whereof 6 used ASCs for enrichment. We found no convincing evidence of a clinically relevant effect of SVF enrichment in humans. ASC enrichment has shown promising results in enhancing graft retention, but additional clinical trials are needed to substantiate this claim and also determine the optimal concentration of SVF cells/ASCs for enrichment. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  19. Clinical radiation doses for spinal cord: the 1988 international questionnaire

    International Nuclear Information System (INIS)

    Fowler, J.F.; Bogaert, W. vanden; Scheuren, E. van der; Bentzen, S.M.; Bond, S.J.; Ang, K.K.; Kogel, A.J. van der

    2000-01-01

    Emmanuel van der Schueren gave a keynote lecture at the 1988 ASTRO annual conference pointing out that the spinal cord 'tolerance doses' then prescribed were probably unnecessarily cautious, resulting in probable underdosing of some tumours. This lecture was supported both by an international questionnaire which he and two of the present authors had conducted, and by animal experimental data. In 1997 he initiated a 10-year follow-up questionnaire, the results of which are summarised here. The present report analyses the chance in prescriptions from 1988 to 1998 and the variation in prescriptions among various regions of the World. The main conclusion is that prescribed dose levels have increased significantly in this period. Large geographical variations still exist. Among responders who use a formula to correct for changed dose per fraction, 90% are now using the linear-quadratic model vs. 33% in 1988. The current status of clinically acceptable doses to spinal cord in 2-Gy fractions is discussed briefly. Further details from the responses to the 1998 questionnaire will be presented in another publication. (author)

  20. Mean inactivation dose (D)

    International Nuclear Information System (INIS)

    Vijayakumar, S.; Ng, T.C.; Raudkivi, U.; Meaney, T.J.

    1990-01-01

    By predicting treatment outcome to radiotherapy from in vitro radiobiological parameters, not only individual patient treatments can be tailored, but also new promising treatment protocols can be tried in patients in whom unfavorable outcome is predicted. In this respect, choosing the right parameter can be very important. Unlike D 0 and N which provide information of the distal part of the survival curve, mean inactivation dose (D) estimates overall radiosensitivity. However, the parameters reflecting the response at the clinically relevant low-dose region are neglected in the literature. In a literature survey of 98 papers in which survival curves or D 0 /N were used, only in 2 D was used. In 21 papers the D 0 /n values were important in drawing conclusions. By calculating D in 3 of these 21 papers, we show that the conclusion drawn may be altered with the use of D. The importance of ''low-dose-region-parameters'' is reviewed. (orig.)

  1. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, A Ram; Ahn, Sung Min [Dept. of Radiological Science, The Graduate School, Gachon University, Incheon (Korea, Republic of); Lee, In Ja [Dept. of Radiologic technology, Dongnam health University, Suwon (Korea, Republic of)

    2017-09-15

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

  2. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    International Nuclear Information System (INIS)

    Kang, A Ram; Ahn, Sung Min; Lee, In Ja

    2017-01-01

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied

  3. A clinically relevant major cross-reactive allergen from mesquite tree pollen.

    Science.gov (United States)

    Dhyani, A; Singh, B P; Arora, N; Jain, V K; Sridhara, S

    2008-10-01

    Prosopis juliflora (mesquite) is one of the major sources of pollinosis in tropical and semi-arid countries of the world. The present study was undertaken to purify and characterize a major cross-reactive allergen from this tree species. Mesquite pollen extract was purified using reverse-phase chromatography. Allergen characterization was done by electrophoresis, enzyme-linked immunosorbent assay (ELISA) and Western blotting. Clinical relevance of the purified protein was analyzed by in vivo (skin tests) and in vitro experiments such as ELISA, histamine release, peripheral blood mononuclear cells (PBMC) proliferation and cytokine assays. Cross-reactivity of purified protein with allergenic tree species and lima bean (food) was assessed by inhibition assays. A 66-kDa protein was purified from mesquite pollen extract using octadecyl silica resin. Purified protein recognized 90% of mesquite-sensitized patients in skin test and ELISA. It induced significant histamine release in allergic patients' blood and interleukin-4 secretion in the PBMC culture supernatants. Inhibition assays suggested close allergenic relationship of this protein with Ailanthus excelsa, Cassia siamea, Salvadora persica pollen and Phaseolus lunatus (lima bean - an edible legume). A 66-kDa major cross-reactive allergen was isolated from mesquite pollen using single-step purification procedure. The protein seems relevant for clinical applications in allergic disorders.

  4. Skin dose reduction by a clinically viable magnetic deflector

    International Nuclear Information System (INIS)

    Butson, M.J.; Carolan, M.; Metcalfe, J.N.; University of Wollongong, NSW; Mathur, J.N.; Yu, P.; Young, E.; Kan, M.; City University of Hong Kong, Kowloon

    1997-01-01

    A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory mount of a clinical linear accelerator. All field sizes are attainable up to 35 cm x 35 cm at 100 cm SSD. The gap between the magnetic poles can be adjusted, providing the highest field strength for each field size. Magnetic field strengths up to 0.55 Tesla are attainable. For a 6MV x-ray beam with a 10 mm perspex block tray, surface dose is reduced from 29% to 14% and from 59% to 37% for a 20 cm x 20 cm and 35 cm x 35 cm field size, respectively. Results at varying SSD's have shown at least 10 cm of space must be allowed between the magnets and patient for adequate reduction of skin dose through removal of electron contaminants. (authors)

  5. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  6. The Role and Clinical Relevance of Disseminated Tumor Cells in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Malgorzata Banys

    2014-01-01

    Full Text Available Tumor cell dissemination is a common phenomenon observed in most cancers of epithelial origin. One-third of breast cancer patients present with disseminated tumor cells (DTCs in bone marrow at time of diagnosis; these patients, as well as patients with persistent DTCs, have significantly worse clinical outcome than DTC-negative patients. Since DTC phenotype may differ from the primary tumor with regard to ER and HER2 status, reevaluation of predictive markers on DTCs may optimize treatment choices. In the present review, we report on the clinical relevance of DTC detection in breast cancer.

  7. SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

    International Nuclear Information System (INIS)

    Hoffman, D; Nair, C Kumaran; Wright, C; Yamamoto, T; Mayadev, J; Valicenti, R; Benedict, S; Rong, Y; Markham, J

    2016-01-01

    Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and

  8. SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D; Nair, C Kumaran; Wright, C; Yamamoto, T; Mayadev, J; Valicenti, R; Benedict, S; Rong, Y [University of California Davis Medical Center, Sacramento, CA (United States); Markham, J [Raysearch Laboratories, Garden City, NY (United States)

    2016-06-15

    Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and

  9. Prevalence of Potential and Clinically Relevant Statin-Drug Interactions in Frail and Robust Older Inpatients.

    Science.gov (United States)

    Thai, Michele; Hilmer, Sarah; Pearson, Sallie-Anne; Reeve, Emily; Gnjidic, Danijela

    2015-10-01

    A significant proportion of older people are prescribed statins and are also exposed to polypharmacy, placing them at increased risk of statin-drug interactions. To describe the prevalence rates of potential and clinically relevant statin-drug interactions in older inpatients according to frailty status. A cross-sectional study of patients aged ≥65 years who were prescribed a statin and were admitted to a teaching hospital between 30 July and 10 October 2014 in Sydney, Australia, was conducted. Data on socio-demographics, comorbidities and medications were collected using a standardized questionnaire. Potential statin-drug interactions were defined if listed in the Australian Medicines Handbook and three international drug information sources: the British National Formulary, Drug Interaction Facts and Drug-Reax(®). Clinically relevant statin-drug interactions were defined as interactions with the highest severity rating in at least two of the three international drug information sources. Frailty was assessed using the Reported Edmonton Frail Scale. A total of 180 participants were recruited (median age 78 years, interquartile range 14), 35.0% frail and 65.0% robust. Potential statin-drug interactions were identified in 10% of participants, 12.7% of frail participants and 8.5% of robust participants. Clinically relevant statin-drug interactions were identified in 7.8% of participants, 9.5% of frail participants and 6.8% of robust participants. Depending on the drug information source used, the prevalence rates of potential and clinically relevant statin-drug interactions ranged between 14.4 and 35.6% and between 14.4 and 20.6%, respectively. In our study of frail and robust older inpatients taking statins, the overall prevalence of potential statin-drug interactions was low and varied significantly according to the drug information source used.

  10. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  11. Inverse optimization of objective function weights for treatment planning using clinical dose-volume histograms

    Science.gov (United States)

    Babier, Aaron; Boutilier, Justin J.; Sharpe, Michael B.; McNiven, Andrea L.; Chan, Timothy C. Y.

    2018-05-01

    We developed and evaluated a novel inverse optimization (IO) model to estimate objective function weights from clinical dose-volume histograms (DVHs). These weights were used to solve a treatment planning problem to generate ‘inverse plans’ that had similar DVHs to the original clinical DVHs. Our methodology was applied to 217 clinical head and neck cancer treatment plans that were previously delivered at Princess Margaret Cancer Centre in Canada. Inverse plan DVHs were compared to the clinical DVHs using objective function values, dose-volume differences, and frequency of clinical planning criteria satisfaction. Median differences between the clinical and inverse DVHs were within 1.1 Gy. For most structures, the difference in clinical planning criteria satisfaction between the clinical and inverse plans was at most 1.4%. For structures where the two plans differed by more than 1.4% in planning criteria satisfaction, the difference in average criterion violation was less than 0.5 Gy. Overall, the inverse plans were very similar to the clinical plans. Compared with a previous inverse optimization method from the literature, our new inverse plans typically satisfied the same or more clinical criteria, and had consistently lower fluence heterogeneity. Overall, this paper demonstrates that DVHs, which are essentially summary statistics, provide sufficient information to estimate objective function weights that result in high quality treatment plans. However, as with any summary statistic that compresses three-dimensional dose information, care must be taken to avoid generating plans with undesirable features such as hotspots; our computational results suggest that such undesirable spatial features were uncommon. Our IO-based approach can be integrated into the current clinical planning paradigm to better initialize the planning process and improve planning efficiency. It could also be embedded in a knowledge-based planning or adaptive radiation therapy framework to

  12. A Novel Admixture-Based Pharmacogenetic Approach to Refine Warfarin Dosing in Caribbean Hispanics

    Science.gov (United States)

    Claudio-Campos, Karla; Rivera-Miranda, Giselle; Bermúdez-Bosch, Luis; Renta, Jessicca Y.; Cadilla, Carmen L.; Cruz, Iadelisse; Feliu, Juan F.; Vergara, Cunegundo; Ruaño, Gualberto

    2016-01-01

    Aim This study is aimed at developing a novel admixture-adjusted pharmacogenomic approach to individually refine warfarin dosing in Caribbean Hispanic patients. Patients & Methods A multiple linear regression analysis of effective warfarin doses versus relevant genotypes, admixture, clinical and demographic factors was performed in 255 patients and further validated externally in another cohort of 55 individuals. Results The admixture-adjusted, genotype-guided warfarin dosing refinement algorithm developed in Caribbean Hispanics showed better predictability (R2 = 0.70, MAE = 0.72mg/day) than a clinical algorithm that excluded genotypes and admixture (R2 = 0.60, MAE = 0.99mg/day), and outperformed two prior pharmacogenetic algorithms in predicting effective dose in this population. For patients at the highest risk of adverse events, 45.5% of the dose predictions using the developed pharmacogenetic model resulted in ideal dose as compared with only 29% when using the clinical non-genetic algorithm (pwarfarin dose variance when externally validated in 55 individuals from an independent validation cohort (MAE = 0.89 mg/day, 24% mean bias). Conclusions Results supported our rationale to incorporate individual’s genotypes and unique admixture metrics into pharmacogenetic refinement models in order to increase predictability when expanding them to admixed populations like Caribbean Hispanics. Trial Registration ClinicalTrials.gov NCT01318057 PMID:26745506

  13. An Internet-ready database for prospective randomized clinical trials of high-dose-rate brachytherapy for adenocarcinoma of the prostate

    International Nuclear Information System (INIS)

    Devlin, Phillip M.; Brus, Christina R.; Kazakin, Julia; Mitchell, Ronald B.; Demanes, D. Jeffrey; Edmundson, Gregory; Gribble, Michael; Gustafson, Gary S.; Kelly, Douglas A.; Linares, Luis A.; Martinez, Alvaro A.; Mate, Timothy P.; Nag, Subir; Perez, Carlos A.; Rao, Jaynath G.; Rodriguez, Rodney R.; Shasha, Daniel; Tripuraneni, Prabhakar

    2002-01-01

    Purpose: To demonstrate a new interactive Internet-ready database for prospective clinical trials in high-dose-rate (HDR) brachytherapy for prostate cancer. Methods and Materials: An Internet-ready database was created that allows common data acquisition and statistical analysis. Patient anonymity and confidentiality are preserved. These data forms include all common elements found from a survey of the databases. The forms allow the user to view patient data in a view-only or edit mode. Eight linked forms document patient data before and after receiving HDR therapy. The pretreatment forms are divided into four categories: staging, comorbid diseases, external beam radiotherapy data, and signs and symptoms. The posttreatment forms separate data by HDR implant information, HDR medications, posttreatment signs and symptoms, and follow-up data. The forms were tested for clinical usefulness. Conclusion: This Internet-based database enables the user to record and later analyze all relevant medical data and may become a reliable instrument for the follow-up of patients and evaluation of treatment results

  14. Locating relevant patient information in electronic health record data using representations of clinical concepts and database structures.

    Science.gov (United States)

    Pan, Xuequn; Cimino, James J

    2014-01-01

    Clinicians and clinical researchers often seek information in electronic health records (EHRs) that are relevant to some concept of interest, such as a disease or finding. The heterogeneous nature of EHRs can complicate retrieval, risking incomplete results. We frame this problem as the presence of two gaps: 1) a gap between clinical concepts and their representations in EHR data and 2) a gap between data representations and their locations within EHR data structures. We bridge these gaps with a knowledge structure that comprises relationships among clinical concepts (including concepts of interest and concepts that may be instantiated in EHR data) and relationships between clinical concepts and the database structures. We make use of available knowledge resources to develop a reproducible, scalable process for creating a knowledge base that can support automated query expansion from a clinical concept to all relevant EHR data.

  15. Resveratrol and Calcium Signaling: Molecular Mechanisms and Clinical Relevance

    Directory of Open Access Journals (Sweden)

    Audrey E. McCalley

    2014-06-01

    Full Text Available Resveratrol is a naturally occurring compound contributing to cellular defense mechanisms in plants. Its use as a nutritional component and/or supplement in a number of diseases, disorders, and syndromes such as chronic diseases of the central nervous system, cancer, inflammatory diseases, diabetes, and cardiovascular diseases has prompted great interest in the underlying molecular mechanisms of action. The present review focuses on resveratrol, specifically its isomer trans-resveratrol, and its effects on intracellular calcium signaling mechanisms. As resveratrol’s mechanisms of action are likely pleiotropic, its effects and interactions with key signaling proteins controlling cellular calcium homeostasis are reviewed and discussed. The clinical relevance of resveratrol’s actions on excitable cells, transformed or cancer cells, immune cells and retinal pigment epithelial cells are contrasted with a review of the molecular mechanisms affecting calcium signaling proteins on the plasma membrane, cytoplasm, endoplasmic reticulum, and mitochondria. The present review emphasizes the correlation between molecular mechanisms of action that have recently been identified for resveratrol and their clinical implications.

  16. [Relevance of drug use in clinical manifestations of schizophrenia].

    Science.gov (United States)

    Arias Horcajadas, F; Sánchez Romero, S; Padín Calo, J J

    2002-01-01

    To study the association between drugs use with schizophrenia clinical manifestations. The sample consists of 82 out-patients with schizophrenia, between 18 and 45 years old. They were evaluated with Addiction Severity Index (ASI) and with Positive and Negative Syndrome Scale (PANSS). A 6 months follow up was carried out. 37,8% patients had lifetime drug dependence (including alcohol and others drugs except for tobacco). The prevalence of dependence for the different drugs were: opioids 9,8%, cocaine 11%, alcohol 29,3%, cannabis 24,4%, tobacco 68,3%, caffeine 15,9%. Drug dependent had more family and legal problems. At the multiple regression analysis it was observed that cannabis and tobacco dependence was associated with a decrease in the PANSS negative symptoms subscale, and on the contrary, alcohol dependence produces a similar intensity increase at that scoring. We don't detect any clinical relevance effects over positive symptoms. Cannabis and tobacco may improve schizophrenia negative symptoms or neuroleptic secondary effects or patients with few negative symptoms may have more predisposition to the use, on the contrary alcohol use can impairment those symptoms.

  17. Clinical dosing regimen of selinexor maintains normal immune homeostasis and T cell effector function in mice: implications for combination with immunotherapy

    Science.gov (United States)

    Tyler, Paul M.; Servos, Mariah M.; de Vries, Romy C.; Klebanov, Boris; Kashyap, Trinayan; Sacham, Sharon; Landesman, Yosef; Dougan, Michael; Dougan, Stephanie K.

    2017-01-01

    Selinexor (KPT-330) is a first in class nuclear transport inhibitor currently in clinical trials as an anti-cancer agent. To determine how selinexor might impact anti-tumor immunity, we analyzed immune homeostasis in mice treated with selinexor and found disruptions in T cell development, a progressive loss of CD8 T cells and increases in inflammatory monocytes. Antibody production in response to immunization was mostly normal. Precursor populations in bone marrow and thymus were unaffected by selinexor, suggesting that normal immune homeostasis could recover. We found that a high dose of selinexor given once per week preserved nearly normal immune functioning, whereas a lower dose given 3 times per week did not restore immune homeostasis. Both naïve and effector CD8 T cells cultured in vitro showed impaired activation in the presence of selinexor. These experiments suggest that nuclear exportins are required for T cell development and function. We determined the minimum concentration of selinexor required to block T cell activation, and showed that T cell inhibitory effects of selinexor occur at levels above 100nM, corresponding to the first 24 hours post-oral dosing. In a model of implantable melanoma, selinexor treatment at 10 mg/kg with a 5 day drug holiday led to intratumoral IFNγ+, granzyme B+ cytotoxic CD8 T cells that were comparable to vehicle treated mice. Overall, selinexor treatment leads to transient inhibition of T cell activation but clinically relevant once and twice weekly dosing schedules that incorporate sufficient drug holidays allow for normal CD8 T cell functioning and development of anti-tumor immunity. PMID:28148714

  18. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  19. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    Energy Technology Data Exchange (ETDEWEB)

    Almen, A J

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs.

  20. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    International Nuclear Information System (INIS)

    Almen, A.J.

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs

  1. EXTRACELLULAR VESICLES: CLASSIFICATION, FUNCTIONS AND CLINICAL RELEVANCE

    Directory of Open Access Journals (Sweden)

    A. V. Oberemko

    2014-12-01

    Full Text Available This review presents a generalized definition of vesicles as bilayer extracellular organelles of all celular forms of life: not only eu-, but also prokaryotic. The structure and composition of extracellular vesicles, history of research, nomenclature, their impact on life processes in health and disease are discussed. Moreover, vesicles may be useful as clinical instruments for biomarkers, and they are promising as biotechnological drug. However, many questions in this area are still unresolved and need to be addressed in the future. The most interesting from the point of view of practical health care represents a direction to study the effect of exosomes and microvesicles in the development and progression of a particular disease, the possibility of adjusting the pathological process by means of extracellular vesicles of a particular type, acting as an active ingredient. Relevant is the further elucidation of the role and importance of exosomes to the surrounding cells, tissues and organs at the molecular level, the prospects for the use of non-cellular vesicles as biomarkers of disease.

  2. Clinically Relevant Levels of 4-Aminopyridine Strengthen Physiological Responses in Intact Motor Circuits in Rats, Especially After Pyramidal Tract Injury.

    Science.gov (United States)

    Sindhurakar, Anil; Mishra, Asht M; Gupta, Disha; Iaci, Jennifer F; Parry, Tom J; Carmel, Jason B

    2017-04-01

    4-Aminopyridine (4-AP) is a Food and Drug Administration-approved drug to improve motor function in people with multiple sclerosis. Preliminary results suggest the drug may act on intact neural circuits and not just on demyelinated ones. To determine if 4-AP at clinically relevant levels alters the excitability of intact motor circuits. In anesthetized rats, electrodes were placed over motor cortex and the dorsal cervical spinal cord for electrical stimulation, and electromyogram electrodes were inserted into biceps muscle to measure responses. The motor responses to brain and spinal cord stimulation were measured before and for 5 hours after 4-AP administration both in uninjured rats and rats with a cut lesion of the pyramidal tract. Blood was collected at the same time as electrophysiology to determine drug plasma concentration with a goal of 20 to 100 ng/mL. We first determined that a bolus infusion of 0.32 mg/kg 4-AP was optimal: it produced on average 61.5 ± 1.8 ng/mL over the 5 hours after infusion. This dose of 4-AP increased responses to spinal cord stimulation by 1.3-fold in uninjured rats and 3-fold in rats with pyramidal tract lesion. Responses to cortical stimulation also increased by 2-fold in uninjured rats and up to 4-fold in the injured. Clinically relevant levels of 4-AP strongly augment physiological responses in intact circuits, an effect that was more robust after partial injury, demonstrating its broad potential in treating central nervous system injuries.

  3. Pharmacokinetics, Dose Proportionality, and Bioavailability of Bazedoxifene in Healthy Postmenopausal Women.

    Science.gov (United States)

    McKeand, William

    2017-09-01

    Bazedoxifene is a selective estrogen receptor modulator that has estrogen agonist effects on bone and lipid metabolism while having neutral or estrogen antagonist effects on the breast and endometrium. The present report describes findings from 3 Phase I clinical studies that evaluated the single-dose pharmacokinetics (study 1; n = 84), multiple-dose pharmacokinetics (study 2; n = 23), and absolute bioavailability (study 3; n = 18) of bazedoxifene. All 3 studies enrolled healthy postmenopausal women who were either naturally postmenopausal or had undergone bilateral oophorectomy at least 6 months before the start of the study. Study 1 showed that unconjugated and total (unconjugated and conjugated) bazedoxifene levels increased proportionally with ascending oral doses of bazedoxifene (through the dose range of 5-120 mg). Evaluation with or without food intake was conducted at the 10-mg dose, with no clinically relevant effect on pharmacokinetic parameters. Study 2 showed that bazedoxifene achieved steady state in 1 week and exhibited linear pharmacokinetics in doses of 5 to 40 mg with no unexpected accumulation over the dose range. In accordance with a linear pharmacokinetic profile, mean maximum plasma concentration values increased with increasing dose, with values of 1.6, 6.2, and 12.5 ng/mL for the 5-, 20-, and 40-mg doses, respectively. In study 3, tablet and capsule formulations of bazedoxifene formulations had an estimated oral bioavailability of ~6%. The clearance of bazedoxifene was 0.4 (0.1) L/h/kg based on intravenous administration. The oral formulations had comparable exposure profiles with respect to AUC and AUC0-t, and the 90% CIs for these values were within the bioequivalence limits of 80% to 125%. Bazedoxifene was safe and well tolerated in all 3 studies. These pharmacokinetic evaluations in healthy postmenopausal women found that bazedoxifene displayed linear pharmacokinetics with doses ranging from 5 to 40 mg, with no unexpected accumulation

  4. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  5. The clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults

    DEFF Research Database (Denmark)

    Osterballe, M.; Hansen, T.K.; Mørtz, Charlotte G

    2005-01-01

    BACKGROUND: Previous studies have described cross-reactivity between fresh fruits, vegetables and pollen. However, no data demonstrates the clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults with and without symptoms in the pollen...... season. OBJECTIVE: The aim of this study was to estimate the clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults and to examine the diagnostic value of skin-prick test (SPT), histamine release and specific IgE compared with the outcome...... of oral challenge. METHODS: In total, 936 unselected adults (female : male 479 : 457, median age 33.7 years) were examined for pollen sensitization and clinical cross-reactivity with pollen-related fruits and vegetables by questionnaire, SPT, histamine release, specific IgE and oral challenge. RESULTS...

  6. A clinical decision support system algorithm for intravenous to oral antibiotic switch therapy: validity, clinical relevance and usefulness in a three-step evaluation study.

    Science.gov (United States)

    Akhloufi, H; Hulscher, M; van der Hoeven, C P; Prins, J M; van der Sijs, H; Melles, D C; Verbon, A

    2018-04-26

    To evaluate a clinical decision support system (CDSS) based on consensus-based intravenous to oral switch criteria, which identifies intravenous to oral switch candidates. A three-step evaluation study of a stand-alone CDSS with electronic health record interoperability was performed at the Erasmus University Medical Centre in the Netherlands. During the first step, we performed a technical validation. During the second step, we determined the sensitivity, specificity, negative predictive value and positive predictive value in a retrospective cohort of all hospitalized adult patients starting at least one therapeutic antibacterial drug between 1 and 16 May 2013. ICU, paediatric and psychiatric wards were excluded. During the last step the clinical relevance and usefulness was prospectively assessed by reports to infectious disease specialists. An alert was considered clinically relevant if antibiotics could be discontinued or switched to oral therapy at the time of the alert. During the first step, one technical error was found. The second step yielded a positive predictive value of 76.6% and a negative predictive value of 99.1%. The third step showed that alerts were clinically relevant in 53.5% of patients. For 43.4% it had already been decided to discontinue or switch the intravenous antibiotics by the treating physician. In 10.1%, the alert resulted in advice to change antibiotic policy and was considered useful. This prospective cohort study shows that the alerts were clinically relevant in >50% (n = 449) and useful in 10% (n = 85). The CDSS needs to be evaluated in hospitals with varying activity of infectious disease consultancy services as this probably influences usefulness.

  7. Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert

    2018-05-01

    The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.

  8. Streptococcus pyogenes biofilms – formation, biology,and clinical relevance

    Directory of Open Access Journals (Sweden)

    Tomas eFiedler

    2015-02-01

    Full Text Available Streptococcus pyogenes (group A streptococci, GAS is an exclusive human bacterial pathogen. The virulence potential of this species is tremendous. Interactions with humans range from asymptomatic carriage over mild and superficial infections of skin and mucosal membranes up to systemic purulent toxic-invasive disease manifestations. Particularly the latter are a severe threat for predisposed patients and lead to significant death tolls worldwide. This places GAS among the most important Gram-positive bacterial pathogens. Many recent reviews have highlighted the GAS repertoire of virulence factors, regulators and regulatory circuits/networks that enable GAS to colonize the host and to deal with all levels of the host immune defense. This covers in vitro and in vivo studies, including animal infection studies based on mice and more relevant, macaque monkeys. It is now appreciated that GAS, like many other bacterial species, do not necessarily exclusively live in a planktonic lifestyle. GAS is capable of microcolony and biofilm formation on host cells and tissues. We are now beginning to understand that this feature significantly contributes to GAS pathogenesis. In this review we will discuss the current knowledge on GAS biofilm formation, the biofilm-phenotype associated virulence factors, regulatory aspects of biofilm formation, the clinical relevance, and finally contemporary treatment regimens and future treatment options.

  9. Development of clinically relevant implantable pressure sensors: perspectives and challenges.

    Science.gov (United States)

    Clausen, Ingelin; Glott, Thomas

    2014-09-22

    This review describes different aspects to consider when developing implantable pressure sensor systems. Measurement of pressure is in general highly important in clinical practice and medical research. Due to the small size, light weight and low energy consumption Micro Electro Mechanical Systems (MEMS) technology represents new possibilities for monitoring of physiological parameters inside the human body. Development of clinical relevant sensors requires close collaboration between technological experts and medical clinicians.  Site of operation, size restrictions, patient safety, and required measurement range and resolution, are only some conditions that must be taken into account. An implantable device has to operate under very hostile conditions. Long-term in vivo pressure measurements are particularly demanding because the pressure sensitive part of the sensor must be in direct or indirect physical contact with the medium for which we want to detect the pressure. New sensor packaging concepts are demanded and must be developed through combined effort between scientists in MEMS technology, material science, and biology. Before launching a new medical device on the market, clinical studies must be performed. Regulatory documents and international standards set the premises for how such studies shall be conducted and reported.

  10. Single Dose Versus 3 Doses of Intramuscular Benzathine Penicillin for Early Syphilis in HIV: A Randomized Clinical Trial.

    Science.gov (United States)

    Andrade, Roberto; Rodriguez-Barradas, Maria C; Yasukawa, Kosuke; Villarreal, Erick; Ross, Michael; Serpa, Jose A

    2017-03-15

    Patients coinfected with syphilis and human immunodeficiency virus (HIV) may have a slower decrease in rapid plasma reagin (RPR) titers. Currently a single dose of 2.4 million units of intramuscular benzathine penicillin G (BPG) is recommended for the treatment of early syphilis. Some observational studies have suggested that this regimen may lead to high failure rates in coinfected patients. We conducted an open-label randomized clinical trial to compare the efficacy of single-dose and 3-dose regimens of BPG for the treatment of early syphilis in HIV-infected individuals. RPR titers were monitored every 3 months. Treatment success was defined as a decrease in RPR titers of ≥2 dilutions (4-fold) during a 12-month follow-up period. Sixty-four patients were included. In the intention-to-treat analysis, treatment success rates were 80% (28 of 35 subjects) and 93% (27 of 29 subjects) in the single-dose and 3-dose regimens, respectively (absolute difference, 13% [95% confidence interval {CI}, -5% to 30%; P = .17). In the per-protocol analysis, success rates were 93% (27 of 29) and 100% in the single-dose and 3-dose regimens, respectively (absolute difference, 7% [95% CI, -7% to 22%]; P = .49). CD4 T-cell count, RPR titer and syphilis stage did not affect treatment results. When compared with a single dose of BPG, a 3-dose regimen did not improve syphilis serological outcomes. Our results support the Centers for Disease Control and Prevention recommendation of a single dose of BPG in HIV-infected patients with early syphilis. NCT02611765. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  11. Molecular Characterization and Clinical Relevance of Metabolic Expression Subtypes in Human Cancers

    Directory of Open Access Journals (Sweden)

    Xinxin Peng

    2018-04-01

    Full Text Available Summary: Metabolic reprogramming provides critical information for clinical oncology. Using molecular data of 9,125 patient samples from The Cancer Genome Atlas, we identified tumor subtypes in 33 cancer types based on mRNA expression patterns of seven major metabolic processes and assessed their clinical relevance. Our metabolic expression subtypes correlated extensively with clinical outcome: subtypes with upregulated carbohydrate, nucleotide, and vitamin/cofactor metabolism most consistently correlated with worse prognosis, whereas subtypes with upregulated lipid metabolism showed the opposite. Metabolic subtypes correlated with diverse somatic drivers but exhibited effects convergent on cancer hallmark pathways and were modulated by highly recurrent master regulators across cancer types. As a proof-of-concept example, we demonstrated that knockdown of SNAI1 or RUNX1—master regulators of carbohydrate metabolic subtypes—modulates metabolic activity and drug sensitivity. Our study provides a system-level view of metabolic heterogeneity within and across cancer types and identifies pathway cross-talk, suggesting related prognostic, therapeutic, and predictive utility. : Peng et al. analyze a cohort of 9,125 TCGA samples across 33 cancer types to characterize tumor subtypes based on the expression of seven metabolic pathways. They find metabolic expression subtypes are associated with patient survivals and suggest the therapeutic and predictive relevance of subtype-related master regulators. Keywords: The Cancer Genome Atlas, tumor subtypes, prognostic markers, somatic drivers, master regulator, therapeutic targets, drug sensitivity, carbohydrate metabolism

  12. Statistical significance versus clinical relevance.

    Science.gov (United States)

    van Rijn, Marieke H C; Bech, Anneke; Bouyer, Jean; van den Brand, Jan A J G

    2017-04-01

    In March this year, the American Statistical Association (ASA) posted a statement on the correct use of P-values, in response to a growing concern that the P-value is commonly misused and misinterpreted. We aim to translate these warnings given by the ASA into a language more easily understood by clinicians and researchers without a deep background in statistics. Moreover, we intend to illustrate the limitations of P-values, even when used and interpreted correctly, and bring more attention to the clinical relevance of study findings using two recently reported studies as examples. We argue that P-values are often misinterpreted. A common mistake is saying that P < 0.05 means that the null hypothesis is false, and P ≥0.05 means that the null hypothesis is true. The correct interpretation of a P-value of 0.05 is that if the null hypothesis were indeed true, a similar or more extreme result would occur 5% of the times upon repeating the study in a similar sample. In other words, the P-value informs about the likelihood of the data given the null hypothesis and not the other way around. A possible alternative related to the P-value is the confidence interval (CI). It provides more information on the magnitude of an effect and the imprecision with which that effect was estimated. However, there is no magic bullet to replace P-values and stop erroneous interpretation of scientific results. Scientists and readers alike should make themselves familiar with the correct, nuanced interpretation of statistical tests, P-values and CIs. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  13. Skin dose reduction by a clinically viable magnetic deflector

    Energy Technology Data Exchange (ETDEWEB)

    Butson, M.J.; Carolan, M.; Metcalfe, J.N. [Illawarra Cancer Centre, NSW (Australia). Department of Radiotherapy]|[University of Wollongong, NSW (Australia). Department of Physics; Mathur, J.N. [University of Wollongong, NSW (Australia). Department of Physics; Yu, P.; Young, E. [City University of Hong Kong, Kowloon (Hong Kong). Department of Physics; Kan, M. [Hong Kong Polytechnic University, Kowloon (Hong Kong). Department of Optometry and Radiography]|[City University of Hong Kong, Kowloon (Hong Kong). Department of Physics

    1997-06-01

    A variable magnetic deflector which attaches onto the treatment head of a linear accelerator has reduced skin dose by as much as 65% for 6MV x-rays. The magnetic deflector is constructed from Neodymium Iron Boron (NdFeB) rare earth magnets. It weighs approximately 15 kg and is designed to easily fit onto the accessory mount of a clinical linear accelerator. All field sizes are attainable up to 35 cm x 35 cm at 100 cm SSD. The gap between the magnetic poles can be adjusted, providing the highest field strength for each field size. Magnetic field strengths up to 0.55 Tesla are attainable. For a 6MV x-ray beam with a 10 mm perspex block tray, surface dose is reduced from 29% to 14% and from 59% to 37% for a 20 cm x 20 cm and 35 cm x 35 cm field size, respectively. Results at varying SSD`s have shown at least 10 cm of space must be allowed between the magnets and patient for adequate reduction of skin dose through removal of electron contaminants. (authors). 14 refs., 6 figs.

  14. Clinical study of double dose of valsartan combined with tacrolimus in treatment of diabetic nephropathy.

    Science.gov (United States)

    Jin, H; Zhang, H-N; Hou, X-L; Zhang, B; Wu, J; Zhang, H-B

    2016-01-01

    To investigate the clinical effect of double dose of valsartan combined with tacrolimus in the treatment of diabetic nephropathy (DN). HA total of 86 cases diagnosed with DN were selected from October 2013 to October 2014 in Zaozhuang Municipal Hospital, China. The study was approved by our hospital Ethics Committee and written consent was obtained from patients and their family members. Patients were randomly divided into three groups according to the sequence of admission, group A (conventional dose of valsartan group, n = 28 cases), group B (double dose of valsartan group, n = 29 cases) and group C (double dose of valsartan combined with tacrolimus group, n = 29). Clinical effects were compared by analyzing the renal function tests after 8 weeks. 24h urine protein, serum creatinine level of patients in group B and group C were significantly lower than that of group A. Those in group C was much lower. The glomerular filtration rates were significantly higher for group B and C than that of group A, and those in group C were much higher. The difference is statistically significant (p valsartan combined with tacrolimus treatment of DN patients can improve clinical symptoms, reducing inflammation, inhibiting or even reversing the interstitial fibrosis, which will improve the curative effect and reduce the recurrence, as to provide a new theoretical basis for the clinical treatment of the disease.

  15. Investigation of tilted dose kernels for portal dose prediction in a-Si electronic portal imagers

    International Nuclear Information System (INIS)

    Chytyk, K.; McCurdy, B. M. C.

    2006-01-01

    The effect of beam divergence on dose calculation via Monte Carlo generated dose kernels was investigated in an amorphous silicon electronic portal imaging device (EPID). The flat-panel detector was simulated in EGSnrc with an additional 3.0 cm water buildup. The model included details of the detector's imaging cassette and the front cover upstream of it. To approximate the effect of the EPID's rear housing, a 2.1 cm air gap and 1.0 cm water slab were introduced into the simulation as equivalent backscatter material. Dose kernels were generated with an incident pencil beam of monoenergetic photons of energy 0.1, 2, 6, and 18 MeV. The orientation of the incident pencil beam was varied from 0 deg. to 14 deg. in 2 deg. increments. Dose was scored in the phosphor layer of the detector in both cylindrical (at 0 deg. ) and Cartesian (at 0 deg. -14 deg.) geometries. To reduce statistical fluctuations in the Cartesian geometry simulations at large radial distances from the incident pencil beam, the voxels were first averaged bilaterally about the pencil beam and then combined into concentric square rings of voxels. Profiles of the EPID dose kernels displayed increasing asymmetry with increasing angle and energy. A comparison of the superposition (tilted kernels) and convolution (parallel kernels) dose calculation methods via the χ-comparison test (a derivative of the γ-evaluation) in worst-case-scenario geometries demonstrated an agreement between the two methods within 0.0784 cm (one pixel width) distance-to-agreement and up to a 1.8% dose difference. More clinically typical field sizes and source-to-detector distances were also tested, yielding at most a 1.0% dose difference and the same distance-to-agreement. Therefore, the assumption of parallel dose kernels has less than a 1.8% dosimetric effect in extreme cases and less than a 1.0% dosimetric effect in most clinically relevant situations and should be suitable for most clinical dosimetric applications. The

  16. Music's relevance for children with cancer: music therapists' qualitative clinical data-mining research.

    Science.gov (United States)

    O'Callaghan, Clare; Dun, Beth; Baron, Annette; Barry, Philippa

    2013-01-01

    Music is central in most children's lives. Understanding its relevance will advance efficacious pediatric supportive cancer care. Qualitative clinical data-mining uncovered four music therapists' perspectives about music and music therapy's relevance for pediatric oncology patients up to 14 years old. Inductive and comparative thematic analysis was performed on focus group transcripts and qualitative interrater reliability integrated. Music can offer children a safe haven for internalizing a healthy self-image alongside patient identity. Music therapy can calm, relieve distress, promote supportive relationships, enable self-care, and inspire playful creativity, associated with "normalcy" and hope. Preferred music and music therapy should be available in pediatric oncology.

  17. Mild obstructive sleep apnoea: clinical relevance and approaches to management.

    Science.gov (United States)

    McNicholas, Walter T; Bonsignore, Maria R; Lévy, Patrick; Ryan, Silke

    2016-10-01

    Obstructive sleep apnoea is highly prevalent in the general population worldwide, especially in its mild form. Clinical manifestations correlate poorly with disease severity measured by the apnoea-hypopnoea index (AHI), which complicates diagnosis. Full polysomnography might be more appropriate to assess suspected mild cases because limited ambulatory diagnostic systems are least accurate in mild disease. Treatment options in mild obstructive sleep apnoea include continuous positive airway pressure (CPAP) and oral appliance therapy, in addition to positional therapy and weight reduction when appropriate. The superior efficacy of CPAP in reducing AHI is offset by greater tolerance of oral appliances, especially in mild disease. Although severe obstructive sleep apnoea is associated with adverse health consequences, including cardiometabolic comorbidities, the association with mild disease is unclear, and reports differ regarding the clinical relevance of mild obstructive sleep apnoea. Improved diagnostic techniques and evidence-based approaches to management in mild obstructive sleep apnoea require further research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays.

    Science.gov (United States)

    Zygmanski, Piotr; Sajo, Erno

    2016-01-01

    We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopic dosimetry for monoenergetic and clinical beams. Among other aspects, we discuss Monte Carlo and deterministic methods and their applications to predicting dose enhancement using various metrics.

  19. Making the history of psychology clinically and philosophically relevant.

    Science.gov (United States)

    Vande Kemp, Hendrika

    2002-08-01

    The author discusses ways to make the history of psychology course relevant for a clinical psychology doctoral program within a multidenominational Protestant theological seminary. She uses a personalist orientation to emphasize the need to integrate psychology, philosophy, and theology. She differentiates among the intrapersonal, interpersonal, impersonal, and transpersonal dimensions of experience. She illustrates the rich multidisciplinary historical roots of contemporary psychology by tracing the the history of the term psychology and examining its meanings in the existential psychology of Søren Kierkegaard and in the 19th-century novel. She includes brief histories of the "new psychology" and of the unconscious. She describes how she uses the field of psychotheological integration to illustrate principles of historiography and summarizes resources used to supplement traditional textbooks.

  20. Deposition of 90Sr in bone and the relevant dose

    International Nuclear Information System (INIS)

    Kawamura, Hisao

    1976-01-01

    The deposition of fallout 90 Sr in bone and radiation dose from the nuclide in Japan is reviewed with special reference to (i) the intraskeletal distribution of 90 Sr and reference bone, (ii) bone models for predicting 90 Sr level and (iii) possible problems in applying dose rate factors to Japanese, especially to infants and adolescents. An evidence is presented for the assumption that the ratio of the 90 Sr concentration in a particular bone to that in vertebra will reach the ratio observed for stable strontium under the virtually constant intake of 90 Sr. The importance of surveying 90 Sr levels in different bones is stressed. Observed Ratios (bone/diet) found for Japanese are noticeably lower than those reported for Europeans and Americans. The recently presented model for the retention of alkaline earth elements in man by ICRP will be useful if only adults are concerned. Dose rate factors for 90 Sr in bone should be given as a function of age for the purpose of better estimation of dose commitments. The cumulative absorbed doses to bone tissues calculated with the Palmley-Mays model and with the Spiers model show remarkably higher levels in school children and young adults than the mean level. (auth.)

  1. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  2. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  3. A Novel Admixture-Based Pharmacogenetic Approach to Refine Warfarin Dosing in Caribbean Hispanics.

    Directory of Open Access Journals (Sweden)

    Jorge Duconge

    Full Text Available This study is aimed at developing a novel admixture-adjusted pharmacogenomic approach to individually refine warfarin dosing in Caribbean Hispanic patients.A multiple linear regression analysis of effective warfarin doses versus relevant genotypes, admixture, clinical and demographic factors was performed in 255 patients and further validated externally in another cohort of 55 individuals.The admixture-adjusted, genotype-guided warfarin dosing refinement algorithm developed in Caribbean Hispanics showed better predictability (R2 = 0.70, MAE = 0.72mg/day than a clinical algorithm that excluded genotypes and admixture (R2 = 0.60, MAE = 0.99mg/day, and outperformed two prior pharmacogenetic algorithms in predicting effective dose in this population. For patients at the highest risk of adverse events, 45.5% of the dose predictions using the developed pharmacogenetic model resulted in ideal dose as compared with only 29% when using the clinical non-genetic algorithm (p<0.001. The admixture-driven pharmacogenetic algorithm predicted 58% of warfarin dose variance when externally validated in 55 individuals from an independent validation cohort (MAE = 0.89 mg/day, 24% mean bias.Results supported our rationale to incorporate individual's genotypes and unique admixture metrics into pharmacogenetic refinement models in order to increase predictability when expanding them to admixed populations like Caribbean Hispanics.ClinicalTrials.gov NCT01318057.

  4. Clinical Relevance of Gene Copy Number Variation in Metastatic Clear Cell Renal Cell Carcinoma.

    Science.gov (United States)

    Nouhaud, François-Xavier; Blanchard, France; Sesboue, Richard; Flaman, Jean-Michel; Sabourin, Jean-Christophe; Pfister, Christian; Di Fiore, Frédéric

    2018-02-23

    Gene copy number variations (CNVs) have been reported to be frequent in renal cell carcinoma (RCC), with potential prognostic value for some. However, their clinical utility, especially to guide treatment of metastatic disease remains to be established. Our objectives were to assess CNVs on a panel of selected genes and determine their clinical relevance in patients who underwent treatment of metastatic RCC. The genetic assessment was performed on frozen tissue samples of clear cell metastatic RCC using quantitative multiplex polymerase chain reaction of short fluorescent fragment method to detect CNVs on a panel of 14 genes of interest. The comparison of the electropherogram obtained from both tumor and normal renal adjacent tissue allowed for CNV identification. The clinical, biologic, and survival characteristics were assessed for their associations with the most frequent CNVs. Fifty patients with clear cell metastatic RCC were included. The CNV rate was 21.4%. The loss of CDKN2A and PLG was associated with a higher tumor stage (P relevance, especially those located on CDKN2A, PLG, and ALDOB, in a homogeneous cohort of patients with clear cell metastatic RCC. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Clinical relevance of surgical site infection as defined by the criteria of the Centers for Disease Control and Prevention

    DEFF Research Database (Denmark)

    Henriksen, N A; Meyhoff, C S; Wetterslev, J

    2010-01-01

    Surgical site infection (SSI) is a common complication after abdominal surgery and the Centers for Disease Control and Prevention (CDC) criteria are commonly used for diagnosis and surveillance. The aim of this study was to evaluate whether SSI diagnosed according to CDC is clinically relevant (C...... a suitable standard definition for monitoring and identifying SSI, even if some cases of less clinically significant superficial SSI are included.......Surgical site infection (SSI) is a common complication after abdominal surgery and the Centers for Disease Control and Prevention (CDC) criteria are commonly used for diagnosis and surveillance. The aim of this study was to evaluate whether SSI diagnosed according to CDC is clinically relevant...... hospital stay or referral to an intensive care unit for SSI. The rate of CRSSI was 38 of 54 (70%) in patients with CDC-diagnosed SSI and none in patients without a CDC-diagnosed SSI. Sixty-one percent of the CDC-diagnosed SSIs were superficial, of which 48% were considered clinically relevant...

  6. Clinical Dosing Regimen of Selinexor Maintains Normal Immune Homeostasis and T-cell Effector Function in Mice: Implications for Combination with Immunotherapy.

    Science.gov (United States)

    Tyler, Paul M; Servos, Mariah M; de Vries, Romy C; Klebanov, Boris; Kashyap, Trinayan; Sacham, Sharon; Landesman, Yosef; Dougan, Michael; Dougan, Stephanie K

    2017-03-01

    Selinexor (KPT-330) is a first-in-class nuclear transport inhibitor currently in clinical trials as an anticancer agent. To determine how selinexor might affect antitumor immunity, we analyzed immune homeostasis in mice treated with selinexor and found disruptions in T-cell development, a progressive loss of CD8 T cells, and increases in inflammatory monocytes. Antibody production in response to immunization was mostly normal. Precursor populations in bone marrow and thymus were unaffected by selinexor, suggesting that normal immune homeostasis could recover. We found that a high dose of selinexor given once per week preserved nearly normal immune functioning, whereas a lower dose given 3 times per week did not restore immune homeostasis. Both naïve and effector CD8 T cells cultured in vitro showed impaired activation in the presence of selinexor. These experiments suggest that nuclear exportins are required for T-cell development and function. We determined the minimum concentration of selinexor required to block T-cell activation and showed that T-cell-inhibitory effects of selinexor occur at levels above 100 nmol/L, corresponding to the first 24 hours post-oral dosing. In a model of implantable melanoma, selinexor treatment at 10 mg/kg with a 4-day drug holiday led to intratumoral IFNγ + , granzyme B + cytotoxic CD8 T cells that were comparable with vehicle-treated mice. Overall, selinexor treatment leads to transient inhibition of T-cell activation, but clinically relevant once and twice weekly dosing schedules that incorporate sufficient drug holidays allow for normal CD8 T-cell functioning and development of antitumor immunity. Mol Cancer Ther; 16(3); 428-39. ©2017 AACR See related article by Farren et al., p. 417 . ©2017 American Association for Cancer Research.

  7. Establishment of clinically relevant radioresistant cell lines and their characteristics

    International Nuclear Information System (INIS)

    Fukumoto, Manabu; Kuwahara, Yoshikazu; Suzuki, Masatoshi

    2014-01-01

    Although radiotherapy is one of the major therapeutic modalities for eradicating malignant tumors, the existence of radioresistant cells remains one of the most critical obstacles. Standard radiotherapy consists of fractionated radiation (FR) of 2-Gy X-rays once a day, 5 days a week, over 60 Gy in total. To understand the characteristics of radioresistant cells and to develop more effective radiotherapy, we have established novel radioresistant cell lines by long-term (> 5 years) exposure to moderate doses of fractionated X-rays. While all the parental human cancer cells ceased, their radioresistant derivatives continue to proliferate with daily exposure to 2-Gy FR for more than 30 days. We have coined those cells as 'clinically relevant radioresistant' (CRR) cells. Transplanted tumors into nude mice were also CRR, indicating that CRR cell lines are powerful tools to improve cancer radiotherapy. We have shown that the suppression of autophagic cell death but not apoptosis was mainly involved in cellular radioresistance. An inhibitor of the mTOR pathway which enhances autophagy was effective to overcome CRR tumors induced in nude mice. But the underlined mechanism was not through the inhibition of autophagy. Guanine nucleotide-binding protein 1 (GBP1) over expression was necessary for maintaining the CRR phenotype, but radioresistant cells were not necessarily cancer stem cells (CSCs). Targeting GBP1 positive cancer cells may be a more efficient method in conquering cancer than targeting CSCs. Slight but significant radioresistance was acquired by 0.5 Gy/12 hrs of long-term FR exposures to parental cells for more than 31 days in accordance with cyclinD1 over expression. This acquired radioresistance (ARR) was stably maintained in the tumor cells even on 31 days after the cessation of 0.5-Gy FR. Present observations give a mechanistic insight for ARR of tumor cells through long-term FR exposure, and provide novel therapeutic targets for radiosensitization

  8. Correlation of clinical outcome to the estimated radiation dose from Boron Neutron Capture Therapy (BNCT)

    Energy Technology Data Exchange (ETDEWEB)

    Chadha, M. [Beth Israel Medical Center, NY (United States). Dept. of Radiation Oncology; Coderre, J.A.; Chanana, A.D. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1996-12-31

    A phase I/II trial delivering a single fraction of BNCT using p-Boronophenylalanine-Fructose and epithermal neutrons at the the Brookhaven Medical Research Reactor was initiated in September 1994. The primary endpiont of the study was to evaluate the feasibility and safety of a given BNCT dose. The clinical outcome of the disease was a secondary endpoint of the study. The objective of this paper is to evaluate the correlation of the clinical outcome of patients to the estimated radiation dose from BNCT.

  9. Correlation of clinical outcome to the estimated radiation dose from Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    Chadha, M.

    1996-01-01

    A phase I/II trial delivering a single fraction of BNCT using p-Boronophenylalanine-Fructose and epithermal neutrons at the the Brookhaven Medical Research Reactor was initiated in September 1994. The primary endpiont of the study was to evaluate the feasibility and safety of a given BNCT dose. The clinical outcome of the disease was a secondary endpoint of the study. The objective of this paper is to evaluate the correlation of the clinical outcome of patients to the estimated radiation dose from BNCT

  10. Whole-Exome Sequencing Reveals Clinically Relevant Variants in Family Affected with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Jiaxiu Zhou

    2016-10-01

    Full Text Available Chromosomal microarray (CMA has been suggested as a first tier clinical diagnostic test for ASD. High-throughput sequencing (HTS has associated hundreds of genes associated with ASD. Whole Exome Sequencing (WES was used in combination with CMA to identify clinically-relevant ASD variants. In prior work, a trio-based (father, mother, and proband WGS (Whole Genome Sequencing was used to reveal clinically-relevant de novo, or inherited, rare variants in half (16 / 32 of the ASD families in which all probands had normal, or VOUS (Variant of Uncertain Clinical Significance, CMA results. In this study, after CMA screening chromosome structural abnormalities of a proband affected with ASD, a WES was performed on the patient and parents. Some rare de novo, and inherited, variants were detected using trio-based bioinformatics analysis. ASD variants were ranked by SFARI Gene score, HPO (human phenotype ontology, protein function damage, and manual searching PubMed. Sanger sequencing was used to validated some candidate variants in family members. A de novo homozygous mutation in SPG11 (p.C209F, two inherited, compound-heterozygote mutations in SCN9A (p.Q10R and p.R1893H and BEST1 (p.A135V and p.A297V were confirmed. Heterozygous mutations in TSC1 (p.S487C and SHANK2 (p.Arg569His inherited from mother were also confirmed.

  11. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  12. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  13. Online drug databases: a new method to assess and compare inclusion of clinically relevant information.

    Science.gov (United States)

    Silva, Cristina; Fresco, Paula; Monteiro, Joaquim; Rama, Ana Cristina Ribeiro

    2013-08-01

    Evidence-Based Practice requires health care decisions to be based on the best available evidence. The model "Information Mastery" proposes that clinicians should use sources of information that have previously evaluated relevance and validity, provided at the point of care. Drug databases (DB) allow easy and fast access to information and have the benefit of more frequent content updates. Relevant information, in the context of drug therapy, is that which supports safe and effective use of medicines. Accordingly, the European Guideline on the Summary of Product Characteristics (EG-SmPC) was used as a standard to evaluate the inclusion of relevant information contents in DB. To develop and test a method to evaluate relevancy of DB contents, by assessing the inclusion of information items deemed relevant for effective and safe drug use. Hierarchical organisation and selection of the principles defined in the EGSmPC; definition of criteria to assess inclusion of selected information items; creation of a categorisation and quantification system that allows score calculation; calculation of relative differences (RD) of scores for comparison with an "ideal" database, defined as the one that achieves the best quantification possible for each of the information items; pilot test on a sample of 9 drug databases, using 10 drugs frequently associated in literature with morbidity-mortality and also being widely consumed in Portugal. Main outcome measure Calculate individual and global scores for clinically relevant information items of drug monographs in databases, using the categorisation and quantification system created. A--Method development: selection of sections, subsections, relevant information items and corresponding requisites; system to categorise and quantify their inclusion; score and RD calculation procedure. B--Pilot test: calculated scores for the 9 databases; globally, all databases evaluated significantly differed from the "ideal" database; some DB performed

  14. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  15. Correlation between γ-ray-induced DNA double-strand breakage and cell killing after biologically relevant doses: analysis by pulsed-field gel electrophoresis

    International Nuclear Information System (INIS)

    Murray, D.

    1994-01-01

    We examined the degree of correlation between γ-ray-induced lethality and DNA double-strand breaks (dsbs) after biologically relevant doses of radiation. Radiation lethality was modified by treating 14 C-labelled Chinese hamster ovary cells with either of two aminothiols (WR-1065 or WR-255591) and the associated effect on dsb induction was determined by pulsed-field gel electrophoresis (PFGE). The use of phosphorimaging to analyse the distribution of 14 C-activity in the gel greatly improved the low-dose resolution of the PFGE assay. Both WR-1065 and WR-255591 protected against dsb induction and lethality to a similar extent after low doses of radiation. although this correlation broke down when supralethal doses were used to induce dsbs. Thus, the level of dsbs induced in these cells as measured by PFGE after survival-curve doses of γ-radiation is consistently predictive of the degree of lethality obtained, implying a cause-effect relationship between these two parameters and confirming previous results obtained using the neutral filter elution assay for dsbs. (author)

  16. Retrieving clinically relevant diabetic retinopathy images using a multi-class multiple-instance framework

    Science.gov (United States)

    Chandakkar, Parag S.; Venkatesan, Ragav; Li, Baoxin

    2013-02-01

    Diabetic retinopathy (DR) is a vision-threatening complication from diabetes mellitus, a medical condition that is rising globally. Unfortunately, many patients are unaware of this complication because of absence of symptoms. Regular screening of DR is necessary to detect the condition for timely treatment. Content-based image retrieval, using archived and diagnosed fundus (retinal) camera DR images can improve screening efficiency of DR. This content-based image retrieval study focuses on two DR clinical findings, microaneurysm and neovascularization, which are clinical signs of non-proliferative and proliferative diabetic retinopathy. The authors propose a multi-class multiple-instance image retrieval framework which deploys a modified color correlogram and statistics of steerable Gaussian Filter responses, for retrieving clinically relevant images from a database of DR fundus image database.

  17. Is the clinical relevance of drug-food and drug-herb interactions limited to grapefruit juice and Saint-John's Wort?

    Science.gov (United States)

    Mouly, Stéphane; Lloret-Linares, Célia; Sellier, Pierre-Olivier; Sene, Damien; Bergmann, J-F

    2017-04-01

    An interaction of drug with food, herbs, and dietary supplements is usually the consequence of a physical, chemical or physiologic relationship between a drug and a product consumed as food, nutritional supplement or over-the-counter medicinal plant. The current educational review aims at reminding to the prescribing physicians that the most clinically relevant drug-food interactions may not be strictly limited to those with grapefruit juice and with the Saint John's Wort herbal extract and may be responsible for changes in drug plasma concentrations, which in turn decrease efficacy or led to sometimes life-threatening toxicity. Common situations handled in clinical practice such as aging, concomitant medications, transplant recipients, patients with cancer, malnutrition, HIV infection and those receiving enteral or parenteral feeding may be at increased risk of drug-food or drug-herb interactions. Medications with narrow therapeutic index or potential life-threatening toxicity, e.g., the non-steroidal anti-inflammatory drugs, opioid analgesics, cardiovascular medications, warfarin, anticancer drugs and immunosuppressants may be at risk of significant drug-food interactions to occur. Despite the fact that considerable effort has been achieved to increase patient' and doctor's information and ability to anticipate their occurrence and consequences in clinical practice, a thorough and detailed health history and dietary recall are essential for identifying potential problems in order to optimize patient prescriptions and drug dosing on an individual basis as well as to increase the treatment risk/benefit ratio. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Clinically relevant risk factors for suicide: Comparison between clinical group with passive suicidal ideation, active suicidal ideation and without suicidal ideation

    OpenAIRE

    Miloseva, Lence; Cuijpers, Pim; Stojcev, Saso; Niklewski, Gunter; Richter, Kneginja; Jovevska, Svetlana; Arsova, Roza; Serafimov, Aleksandar

    2015-01-01

    Introduction: In recent years, researchers and clinicians do not treat passive suicidal ideation as a clinically relevant risk factor for suicide, while underestimating the strength of this desire to die, compared with making a plan for suicide in individuals having active suicidal ideation. This research study is clinically prospective, cross-sequential, but also partly retrospective because it involves also variables from the past, such as patients’ history data (number of suicidal attempts...

  19. Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Woussen, S.; Vanbeckevoort, D.; Bosmans, H.; Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Lopez-Rendon, X.; Zanca, F. [University Hospitals Leuven, Department of Imaging and Pathology, Leuven (Belgium)

    2016-04-15

    To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. (orig.)

  20. Clinically relevant magnetic resonance imaging (MRI findings in elite swimmers’ shoulders

    Directory of Open Access Journals (Sweden)

    Arno Celliers

    2017-01-01

    Objective: To assess clinically relevant MRI findings in the shoulders of symptomatic and asymptomatic elite swimmers. Method: Twenty (aged 16–23 years elite swimmers completed questionnaires on their swimming training, pain and shoulder function. MRI of both shoulders (n = 40 were performed and all swimmers were given a standardised clinical shoulder examination. Results: Both shoulders of 11 male and 9 female elite swimmers (n = 40 were examined. Eleven of the 40 shoulders were clinically symptomatic and 29 were asymptomatic. The most common clinical finding in both the symptomatic and asymptomatic shoulders was impingement during internal rotation, with impingement in 54.5% of the symptomatic shoulders and in 31.0% of the asymptomatic shoulders. The most common MRI findings in the symptomatic and asymptomatic shoulders were supraspinatus tendinosis (45.5% vs. 20.7%, subacromial subdeltoid fluid (45.5% vs. 34.5%, increased signal in the AC Joint (45.5% vs. 37.9% and AC joint arthrosis (36.4% vs. 34.5%. Thirty-nine (97.5% of the shoulders showed abnormal MRI features. Conclusion: MRI findings in the symptomatic and asymptomatic shoulders of young elite swimmers are similar and care should be taken when reporting shoulder MRIs in these athletes. Asymptomatic shoulders demonstrate manifold MRI abnormalities that may be radiologically significant but appear not to be clinically significant.

  1. Enrichment methods to detect bone marrow micrometastases in breast carcinoma patients: clinical relevance

    International Nuclear Information System (INIS)

    Choesmel, Valérie; Pierga, Jean-Yves; Nos, Claude; Vincent-Salomon, Anne; Sigal-Zafrani, Brigitte; Thiery, Jean-Paul; Blin, Nathalie

    2004-01-01

    Improving technologies for the detection and purification of bone marrow (BM) micrometastatic cells in breast cancer patients should lead to earlier prognosis of the risk of relapse and should make it possible to design more appropriate therapies. The technique used has to overcome the challenges resulting from the small number of target cells (one per million hematopoietic cells) and the heterogeneous expression of micrometastatic cell markers. In the present study, we have assessed the clinical relevance of current methods aimed at detecting rare disseminated carcinoma cells. BM aspirates from 32 carcinoma patients were screened for the presence of micrometastatic cells positive for epithelial cell adhesion molecule and positive for cytokeratins, using optimized immunodetection methods. A comparison with data obtained for 46 control BM aspirates and a correlation with the clinical status of patients were performed. We developed a sensitive and efficient immunomagnetic protocol for the enrichment of BM micrometastases. This method was used to divide 32 breast carcinoma patients into three categories according to their epithelial cell adhesion molecule status. These categories were highly correlated with the recently revised American Joint Committee on Cancer staging system for breast cancer, demonstrating the clinical relevance of this simple and reliable immunomagnetic technique. We also evaluated immunocytochemical detection of cytokeratin-positive cells and cytomorphological parameters. Immunocytochemistry-based methods for the detection of BM micrometastases did not provide any information about the clinical status of patients, but helped to refine the immunomagnetic data by confirming the presence of micrometastases in some cases. We also tested a new density gradient centrifugation system, able to enrich the tumor fraction of BM specimens by twofold to threefold as compared with standard Ficoll methods. These improved methods for the detection of

  2. [Enduring relevance. An introduction to the clinical contributions of K. R. Eissler].

    Science.gov (United States)

    Garcia, Emanuel E

    2007-01-01

    The author offers a personal selection and discussion of papers that epitomize the enduring relevance of Eissler's contributions to psychoanalytic therapy. The innovations of technique embodied by these works (on parameters, schizophrenia, adolescence, cure, fees, and the treatment of the dying patient) reveal a therapeutic approach that is a natural extension of psychoanalytic science: patient-centered, maximally comprehensive and appropriately flexible. Firsthand observations of Eissler's clinical manner and a selected bibliography are also presented.

  3. Tenofovir alafenamide (TAF) does not deplete mitochondrial DNA in human T-cell lines at intracellular concentrations exceeding clinically relevant drug exposures.

    Science.gov (United States)

    Stray, Kirsten M; Park, Yeojin; Babusis, Darius; Callebaut, Christian; Cihlar, Tomas; Ray, Adrian S; Perron, Michel

    2017-04-01

    HIV-infected patients treated with certain nucleoside reverse transcriptase inhibitors (NRTIs) have experienced adverse effects due to drug-related mitochondrial toxicity. Tenofovir alafenamide (TAF) is a novel prodrug of the NRTI tenofovir (TFV) with an improved safety profile compared to tenofovir disoproxil fumarate (TDF). Prior in vitro studies have demonstrated that the parent nucleotide TFV has no significant effects on mtDNA synthesis. This study investigated whether clinically relevant TAF and TDF exposures affect mtDNA content in human lymphocytes. First, activated or resting peripheral blood mononuclear cells (PBMCs), as well as MT-2 and Jurkat T-cell lines, were continuously treated with ddC for 10 days to establish their susceptibility to mtDNA depletion. PBMCs had low sensitivity to NRTI-mediated mtDNA depletion in vitro. In contrast, ddC treatment of rapidly dividing MT-2 and Jurkat cells resulted in a dose-dependent decrease in mtDNA. Therefore, these two T-cell lines were selected for evaluating TAF and TDF treatment effects. MT-2 and Jurkat cells were pulse-treated with TAF or TDF every 24 h for 10 days to mimic pharmacologically relevant drug exposures. Pulse treatment of cells with 3.3 μM TAF or 1.1 μM TDF for 10 days resulted in 2- to 7-fold greater steady-state intracellular TFV-diphosphate (TFV-DP) levels than those observed clinically in TAF- or TDF-treated patients. At these concentrations, no significant TAF- (106.7% and 84.1% of control; p = 0.77 and 0.12 for MT-2 and Jurkat, respectively) or TDF- (100.6% and 91.0% of control; p = 0.91 and 0.37, respectively) associated reduction in mtDNA content was observed compared with untreated control cells. This study demonstrates that, despite delivering higher intracellular levels of TFV-DP than TDF, TAF does not inhibit mtDNA synthesis in vitro at concentrations exceeding the clinically relevant intracellular drug exposures. Thus, TAF has a low potential for mitochondrial toxicity in

  4. Low-dose single acquisition rest 99mTc/stress 201Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    International Nuclear Information System (INIS)

    Dey, Thomas; Backus, Barbra E.; Romijn, R.Leo; Wieczorek, Herfried; Verzijlbergen, J.F.

    2014-01-01

    We developed and tested a single acquisition rest 99m Tc-sestamibi/stress 201 Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress 99m Tc and rest 99m Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected 201 Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the 201 Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and 99m Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the 99m Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients no relevant clinical follow

  5. Clinical Utility and Safety of a Model-Based Patient-Tailored Dose of Vancomycin in Neonates.

    Science.gov (United States)

    Leroux, Stéphanie; Jacqz-Aigrain, Evelyne; Biran, Valérie; Lopez, Emmanuel; Madeleneau, Doriane; Wallon, Camille; Zana-Taïeb, Elodie; Virlouvet, Anne-Laure; Rioualen, Stéphane; Zhao, Wei

    2016-04-01

    Pharmacokinetic modeling has often been applied to evaluate vancomycin pharmacokinetics in neonates. However, clinical application of the model-based personalized vancomycin therapy is still limited. The objective of the present study was to evaluate the clinical utility and safety of a model-based patient-tailored dose of vancomycin in neonates. A model-based vancomycin dosing calculator, developed from a population pharmacokinetic study, has been integrated into the routine clinical care in 3 neonatal intensive care units (Robert Debré, Cochin Port Royal, and Clocheville hospitals) between 2012 and 2014. The target attainment rate, defined as the percentage of patients with a first therapeutic drug monitoring serum vancomycin concentration achieving the target window of 15 to 25 mg/liter, was selected as an endpoint for evaluating the clinical utility. The safety evaluation was focused on nephrotoxicity. The clinical application of the model-based patient-tailored dose of vancomycin has been demonstrated in 190 neonates. The mean (standard deviation) gestational and postnatal ages of the study population were 31.1 (4.9) weeks and 16.7 (21.7) days, respectively. The target attainment rate increased from 41% to 72% without any case of vancomycin-related nephrotoxicity. This proof-of-concept study provides evidence for integrating model-based antimicrobial therapy in neonatal routine care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  6. Clinical Relevance of Nontuberculous Mycobacteria Isolated from Sputum in a Gold Mining Workforce in South Africa: An Observational, Clinical Study

    Directory of Open Access Journals (Sweden)

    Clare L. van Halsema

    2015-01-01

    Full Text Available Background. The clinical relevance of nontuberculous mycobacteria (NTM, detected by liquid more than solid culture in sputum specimens from a South African mining workforce, is uncertain. We aimed to describe the current spectrum and relevance of NTM in this population. Methods. An observational study including individuals with sputum NTM isolates, recruited at workforce tuberculosis screening and routine clinics. Symptom questionnaires were administered at the time of sputum collection and clinical records and chest radiographs reviewed retrospectively. Results. Of 232 individuals included (228 (98% male, median age 44 years, M. gordonae (60 individuals, M. kansasii (50, and M. avium complex (MAC: 38 were the commonest species. Of 38 MAC isolates, only 2 (5.3% were from smear-positive sputum specimens and 30/38 grew in liquid but not solid culture. MAC was especially prevalent among symptomatic, HIV-positive individuals. HIV prevalence was high: 57/74 (77% among those tested. No differences were found in probability of death or medical separation by NTM species. Conclusions. M. gordonae, M. kansasii, and MAC were the commonest NTM among miners with suspected tuberculosis, with most MAC from smear-negative specimens in liquid culture only. HIV testing and identification of key pathogenic NTM in this setting are essential to ensure optimal treatment.

  7. Computerized clinical decision support systems for therapeutic drug monitoring and dosing: A decision-maker-researcher partnership systematic review

    Directory of Open Access Journals (Sweden)

    Weise-Kelly Lorraine

    2011-08-01

    Full Text Available Abstract Background Some drugs have a narrow therapeutic range and require monitoring and dose adjustments to optimize their efficacy and safety. Computerized clinical decision support systems (CCDSSs may improve the net benefit of these drugs. The objective of this review was to determine if CCDSSs improve processes of care or patient outcomes for therapeutic drug monitoring and dosing. Methods We conducted a decision-maker-researcher partnership systematic review. Studies from our previous review were included, and new studies were sought until January 2010 in MEDLINE, EMBASE, Evidence-Based Medicine Reviews, and Inspec databases. Randomized controlled trials assessing the effect of a CCDSS on process of care or patient outcomes were selected by pairs of independent reviewers. A study was considered to have a positive effect (i.e., CCDSS showed improvement if at least 50% of the relevant study outcomes were statistically significantly positive. Results Thirty-three randomized controlled trials were identified, assessing the effect of a CCDSS on management of vitamin K antagonists (14, insulin (6, theophylline/aminophylline (4, aminoglycosides (3, digoxin (2, lidocaine (1, or as part of a multifaceted approach (3. Cluster randomization was rarely used (18% and CCDSSs were usually stand-alone systems (76% primarily used by physicians (85%. Overall, 18 of 30 studies (60% showed an improvement in the process of care and 4 of 19 (21% an improvement in patient outcomes. All evaluable studies assessing insulin dosing for glycaemic control showed an improvement. In meta-analysis, CCDSSs for vitamin K antagonist dosing significantly improved time in therapeutic range. Conclusions CCDSSs have potential for improving process of care for therapeutic drug monitoring and dosing, specifically insulin and vitamin K antagonist dosing. However, studies were small and generally of modest quality, and effects on patient outcomes were uncertain, with no convincing

  8. Effect of Genotype-Guided Warfarin Dosing on Clinical Events and Anticoagulation Control Among Patients Undergoing Hip or Knee Arthroplasty: The GIFT Randomized Clinical Trial.

    Science.gov (United States)

    Gage, Brian F; Bass, Anne R; Lin, Hannah; Woller, Scott C; Stevens, Scott M; Al-Hammadi, Noor; Li, Juan; Rodríguez, Tomás; Miller, J Philip; McMillin, Gwendolyn A; Pendleton, Robert C; Jaffer, Amir K; King, Cristi R; Whipple, Brandi DeVore; Porche-Sorbet, Rhonda; Napoli, Lynnae; Merritt, Kerri; Thompson, Anna M; Hyun, Gina; Anderson, Jeffrey L; Hollomon, Wesley; Barrack, Robert L; Nunley, Ryan M; Moskowitz, Gerard; Dávila-Román, Victor; Eby, Charles S

    2017-09-26

    Warfarin use accounts for more medication-related emergency department visits among older patients than any other drug. Whether genotype-guided warfarin dosing can prevent these adverse events is unknown. To determine whether genotype-guided dosing improves the safety of warfarin initiation. The randomized clinical Genetic Informatics Trial (GIFT) of Warfarin to Prevent Deep Vein Thrombosis included patients aged 65 years or older initiating warfarin for elective hip or knee arthroplasty and was conducted at 6 US medical centers. Enrollment began in April 2011 and follow-up concluded in October 2016. Patients were genotyped for the following polymorphisms: VKORC1-1639G>A, CYP2C9*2, CYP2C9*3, and CYP4F2 V433M. In a 2 × 2 factorial design, patients were randomized to genotype-guided (n = 831) or clinically guided (n = 819) warfarin dosing on days 1 through 11 of therapy and to a target international normalized ratio (INR) of either 1.8 or 2.5. The recommended doses of warfarin were open label, but the patients and clinicians were blinded to study group assignment. The primary end point was the composite of major bleeding, INR of 4 or greater, venous thromboembolism, or death. Patients underwent a screening lower-extremity duplex ultrasound approximately 1 month after arthroplasty. Among 1650 randomized patients (mean age, 72.1 years [SD, 5.4 years]; 63.6% women; 91.0% white), 1597 (96.8%) received at least 1 dose of warfarin therapy and completed the trial (n = 808 in genotype-guided group vs n = 789 in clinically guided group). A total of 87 patients (10.8%) in the genotype-guided group vs 116 patients (14.7%) in the clinically guided warfarin dosing group met at least 1 of the end points (absolute difference, 3.9% [95% CI, 0.7%-7.2%], P = .02; relative rate [RR], 0.73 [95% CI, 0.56-0.95]). The numbers of individual events in the genotype-guided group vs the clinically guided group were 2 vs 8 for major bleeding (RR, 0.24; 95% CI, 0

  9. Clinical outcome of one-third-dose depot triptorelin is the same as half-dose depot triptorelin in the long protocol of controlled ovarian stimulation

    Directory of Open Access Journals (Sweden)

    Yu Li

    2012-01-01

    Full Text Available Objective: Appropriate dosage of the long-acting depot gonadotrophin releasing hormone (GnRH agonist has not been determined in long protocol for IVF, and one-third-dose depot triptorelin was compared with half-dose in a luteal long protocol of in-vitro fertilization/ intra cytoplasmic sperm injection (IVF/ICSI treatment in this study. Materials and Methods: This is a prospective, randomized, open clinical trial. 100 patients were randomized into two groups. Group I received one-third-dose (1.25 mg depot triptorelin. Group II received half-dose (1.87 mg. The clinical and experimental parameters were compared between the two groups. Results: There was no premature luteinizing hormone (LH surge in both groups. On Day 3-5 of menstrual cycle after down-regulation, fewer patients showed low-level LH (<1.0 IU/L and estradiol (<30 pg/mL in group I (P <0.05. There were fewer oocytes retrieved (P =0.086, fewer total embryos and available embryos for cryopreservation in Group I (P <0.05, while good-quality embryo rate was higher in group I (P <0.05. The length and dose of ovarian stimulation was lower in Group I, but not significantly. The clinical pregnancy (52% versus 40%, implantation (48% versus 37.5%, delivery (46% versus 32%, or live birth (42% versus 32% rates and the abortion (8% versus 20% rates showed no significant differences. Conclusion: Depot triptorelin 1.25 mg can be successfully used with reduced pituitary suppression and lower cost in a long protocol for in-vitro fertilization.

  10. Increased apoptotic potential and dose-enhancing effect of gold nanoparticles in combination with single-dose clinical electron beams on tumor-bearing mice

    International Nuclear Information System (INIS)

    Chang Mengya; Chen Yuhung; Chang Chihjui; Chen Helen H-W; Wu Chaoliang; Shiau Aili

    2008-01-01

    High atomic number material, such as gold, may be used in conjunction with radiation to provide dose enhancement in tumors. In the current study, we investigated the dose-enhancing effect and apoptotic potential of gold nanoparticles in combination with single-dose clinical electron beams on B16F10 melanoma tumor-bearing mice. We revealed that the accumulation of gold nanoparticles was detected inside B16F10 culture cells after 18 h of incubation, and moreover, the gold nanoparticles were shown to be colocalized with endoplasmic reticulum and Golgi apparatus in cells. Furthermore, gold nanoparticles radiosensitized melanoma cells in the colony formation assay (P=0.02). Using a B16F10 tumor-bearing mouse model, we further demonstrated that gold nanoparticles in conjunction with ionizing radiation significantly retarded tumor growth and prolonged survival compared to the radiation alone controls (P<0.05). Importantly, an increase of apoptotic signals was detected inside tumors in the combined treatment group (P<0.05). Knowing that radiation-induced apoptosis has been considered a determinant of tumor responses to radiation therapy, and the length of tumor regrowth delay correlated with the extent of apoptosis after single-dose radiotherapy, these results may suggest the clinical potential of gold nanoparticles in improving the outcome of melanoma radiotherapy. (author)

  11. Efficacy and Safety of Daikenchuto for Constipation and Dose-Dependent Differences in Clinical Effects

    Directory of Open Access Journals (Sweden)

    Tatsuya Hirose

    2018-01-01

    Full Text Available Background. Daikenchuto (DKT is a Kampo medicine used for the treatment of constipation. In this study, we evaluated the effectiveness of DKT against constipation. Patients and Methods. Thirty-three patients administered DKT for constipation were selected and divided into low-dose (7.5 g DKT; n=22 and high-dose (15 g DKT; n=11 groups. We retrospectively evaluated weekly defaecation frequency, side effects, and clinical laboratory data. Results. Median defaecation frequencies after DKT administration (5, 5.5, 5, and 8 for the first, second, third, and fourth weeks, resp. were significantly higher than that before DKT administration (2 in all 33 cases (P<0.01. One case (3% of watery stool, one case of loose stools (3%, and no cases of abdominal pain (0% were observed. Median defaecation frequencies in the high-dose group (7 and 9 were significantly higher than those in the low-dose group (4 and 3 in the first (P=0.0133 and second (P=0.0101 weeks, respectively. There was no significant change in clinical laboratory values. Conclusion. We suggest that DKT increases defaecation frequency and is safe for treating constipation.

  12. Two clinically relevant pressures of carbon dioxide pneumoperitoneum cause hepatic injury in a rabbit model

    OpenAIRE

    Li, Jun; Liu, Ying-Hai; Ye, Zhan-Yong; Liu, He-Nian; Ou, Shan; Tian, Fu-Zhou

    2011-01-01

    AIM: To observe the hepatic injury induced by carbon dioxide pneumoperitoneum (CDP) in rabbits, compare the effects of low- and high-pressure pneumoperitoneum, and to determine the degree of hepatic injury induced by these two clinically relevant CDP pressures.

  13. Clinical relevance of comorbidity in anxiety disorders : A report from the Netherlands Study of Depression and Anxiety (NESDA)

    NARCIS (Netherlands)

    Hofmeijer-Sevink, Mieke Klein; Batelaan, Neeltje M.; van Megen, Harold J. G. M.; Penninx, Brenda W.; Cath, Danielle C.; van den Hout, Marcel A.; van Balkom, Anton J. L. M.

    Background: To study the clinical relevance of type of comorbidity and number of comorbid disorders in anxiety disorders. Four groups were compared according to sociodemographic-, vulnerability- and clinical factors: single anxiety disorder, anxiety-anxiety comorbidity, anxiety-depressive

  14. Clinical relevance of comorbidity in anxiety disorders: A report from the Netherlands Study of Depression and Anxiety (NESDA)

    NARCIS (Netherlands)

    Klein Hofmeijer-Sevink, M.; Batelaan, N.M.; van Megen, H.J.G.M.; Penninx, B.W.J.H.; Cath, D.C.; van Hout, M.A.; van Balkom, A.J.L.M.

    2012-01-01

    Background: To study the clinical relevance of type of comorbidity and number of comorbid disorders in anxiety disorders. Four groups were compared according to sociodemographic-, vulnerability- and clinical factors: single anxiety disorder, anxiety-anxiety comorbidity, anxiety-depressive

  15. Subclinical Hypothyroidism in Children and Adolescents: Is It Clinically Relevant?

    Directory of Open Access Journals (Sweden)

    Aneta Gawlik

    2015-01-01

    Full Text Available Although subclinical hypothyroidism (SH is a common clinical problem, its diagnosis tends to be incidental. According to the definition, it should be asymptomatic, only detectable by screening. The presence or coincidence of any symptoms leads to L-thyroxine treatment. The clinical presentation, especially in younger patients with subclinical hypothyroidism, is still under dispute. Accordingly, the aim of this paper was to review the literature from the past seven years. The literature search identified 1,594 potentially relevant articles, of which 24 met the inclusion criteria. Few studies focus on the symptomatology of subclinical hypothyroidism, and most of them analyzed a small number of subjects. A significant correlation was found by some authors between subclinical hypothyroidism and a higher risk of hypertension, dyslipidemia, and migraine. No evidence of the impact of subclinical hypothyroidism on weight, growth velocity, and puberty was revealed. As the quality of most studies is poor and no definite conclusions can be drawn, randomized, large-scale studies in children and adolescents are warranted to determine the best care for patients with SH.

  16. Dose optimization in simulated permanent interstitial implant of prostate brachytherapy

    International Nuclear Information System (INIS)

    Faria, Fernando Pereira de

    2006-01-01

    Any treatment of cancer that uses some modality of radiotherapy is planned before being executed. In general the goal in radiotherapy is to irradiate the target to be treated minimizing the incidence of radiation in healthy surrounding tissues. The planning differ among themselves according to the modality of radiotherapy, the type of cancer and where it is located. This work approaches the problem of dose optimization for the planning of prostate cancer treatment through the modality of low dose-rate brachytherapy with Iodine 125 or Palladium 103 seeds. An algorithm for dose calculation and optimization was constructed to find the seeds configuration that better fits the relevant clinical criteria such as as the tolerated dose by the urethra and rectum and the desired dose for prostate. The algorithm automatically finds this configuration from the prostate geometry established in two or three dimensions by using images of ultrasound, magnetic resonance or tomography and from the establishment of minimum restrictions to the positions of the seeds in the prostate and needles in a template. Six patterns of seeds distribution based on clinical criteria were suggested and tested in this work. Each one of these patterns generated a space of possible seeds configurations for the prostate tested by the dose calculation and optimization algorithm. The configurations that satisfied the clinical criteria were submitted to a test according to an optimization function suggested in this work. The configuration that produced maximum value for this function was considered the optimized one. (author)

  17. Chiral drug analysis using mass spectrometric detection relevant to research and practice in clinical and forensic toxicology.

    Science.gov (United States)

    Schwaninger, Andrea E; Meyer, Markus R; Maurer, Hans H

    2012-12-21

    This paper reviews analytical approaches published in 2002-2012 for chiral drug analysis and their relevance in research and practice in the field of clinical and forensic toxicology. Separation systems such as gas chromatography, high performance liquid chromatography, capillary electromigration, and supercritical fluid chromatography, all coupled to mass spectrometry, are discussed. Typical applications are reviewed for relevant chiral analytes such as amphetamines and amphetamine-derived designer drugs, methadone, tramadol, psychotropic and other CNS acting drugs, anticoagulants, cardiovascular drugs, and some other drugs. Usefulness of chiral drug analysis in the interpretation of analytical results in clinical and forensic toxicology is discussed as well. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Combining radiotherapy and ipilimumab induces clinically relevant radiation-induced abscopal effects in metastatic melanoma patients: A systematic review

    Directory of Open Access Journals (Sweden)

    Rodolfo Chicas-Sett

    2018-02-01

    Conclusion: Early clinical outcomes reports suggest that the combination of ipilimumab and RT may improve survival in metastatic melanoma patients. The abscopal responses become a clinically relevant effect of such combination and should be studied in controlled randomized trials.

  19. Clinical value of CARE dose 4D technique in decreasing CT scanning dose of adult chest

    International Nuclear Information System (INIS)

    Wu Aiqin; Zheng Wenlong; Xu Chongyong; Fang Bidong; Ge Wen

    2011-01-01

    Objective: To investigate the value of CARE Dose 4D technique in decreasing radiation dose and improving image quality of multi-slice spiral CT in adult chest scanning. Methods: 100 patients of chest CT scanning were equally divided into study group and control group randomly. CARE Dose 4D Technique was used in study group. Effective mAs value, volume CT dose index (CTDI vol ) and dose length product (DLP) were displayed automatically in machine while chest scanning; those values and actual mAs value of every image were recorded respectively. The image quality at apex of lung, lower edge of aorta arch, middle area of left atrium and base of lung on every image of 400 images was judged and classified as three level (excellent, good, poor) by two deputy chief physicians with double blind method, the image noise at corresponding parts was measured. Results: While setting 80 mAs for quality reference mAs, the effective mAs value in study group most decreased 44 mAs than control group with an average decrease of 9.60 (12.0%), CTDI vol with 4.75 mGy with an average decrease of 0.95 mCy (11.0%), DLP 99.50% in study group, with 98.0% in control group. But it was higher at apex of lung and base of lung, lower at middle area of left atrium, and similar at lower edge of aorta arch in study group than contrast group. The image noise were lower at apex of lung and base of lung in study group than control group (t =6.299 and 2.332, all P<0.05), higher at middle area of left atrium in study group than control group (t=3.078, P<0.05) and similar at lower edge of aorta arch in study group than control group (t=1.191, P>0.05). Conclusions: CARE Dose 4D technique provides a function regulated mAs real-time on line, it not only raises utilization rate of radiation and decreases radiation dose, but also promises and increases image quality in chest CT scanning, and has some clinical significance. (authors)

  20. Paediatric case mix in a rural clinical school is relevant to future practice.

    Science.gov (United States)

    Wright, Helen M; Maley, Moira A L; Playford, Denese E; Nicol, Pam; Evans, Sharon F

    2017-11-29

    Exposure to a representative case mix is essential for clinical learning, with logbooks established as a way of demonstrating patient contacts. Few studies have reported the paediatric case mix available to geographically distributed students within the same medical school. Given international interest in expanding medical teaching locations to rural contexts, equitable case exposure in rural relative to urban settings is topical. The Rural Clinical School of Western Australia locates students up to 3500 km from the urban university for an academic year. There is particular need to examine paediatric case mix as a study reported Australian graduates felt unprepared for paediatric rotations. We asked: Does a rural clinical school provide a paediatric case mix relevant to future practice? How does the paediatric case mix as logged by rural students compare with that by urban students? The 3745 logs of 76 urban and 76 rural consenting medical students were categorised by presenting symptoms and compared to the Australian Institute of Health and Welfare (AIHW) database Major Diagnostic Categories (MDCs). Rural and urban students logged core paediatric cases, in similar order, despite the striking difference in geographic locations. The pattern of overall presenting problems closely corresponded to Australian paediatric hospital admissions. Rural students logged 91% of cases in secondary healthcare settings; urban students logged 90% of cases in tertiary settings. The top four presenting problems were ENT/respiratory, gastrointestinal/urogenital, neurodevelopmental and musculoskeletal; these made up 60% of all cases. Rural and urban students logged similar proportions of infants, children and adolescents, with a variety of case morbidity. Rural clinical school students logged a mix of core paediatric cases relevant to illnesses of Australian children admitted to public hospitals, with similar order and pattern by age group to urban students, despite major differences

  1. A simplified approach for exit dose in vivo measurements in radiotherapy and its clinical application

    International Nuclear Information System (INIS)

    Banjade, D.P.; Shukri, A.; Tajuddin, A.A.; Shrestha, S.L.; Bhat, M.

    2002-01-01

    This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within ±3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10.9 to 14.0% compared to the dose derived from theoretical estimation (normalized dose at d max ). The same measurements for 10 MV beams are lowered by 9.0 to 13.5%. The variations of measured exit dose for different field sizes are found to be within 2.5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1.5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors' viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated for in vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice. Copyright (2002) Australasian College of Physical Scientists and Engineers in Medicine

  2. Prospective Evaluation to Establish a Dose Response for Clinical Oral Mucositis in Patients Undergoing Head-and-Neck Conformal Radiotherapy

    International Nuclear Information System (INIS)

    Narayan, Samir; Lehmann, Joerg; Coleman, Matthew A.; Vaughan, Andrew; Yang, Claus Chunli; Enepekides, Danny; Farwell, Gregory; Purdy, James A.; Laredo, Grace; Nolan, Kerry A.S.; Pearson, Francesca S.; Vijayakumar, Srinivasan

    2008-01-01

    Purpose: We conducted a clinical study to correlate oral cavity dose with clinical mucositis, perform in vivo dosimetry, and determine the feasibility of obtaining buccal mucosal cell samples in patients undergoing head-and-neck radiation therapy. The main objective is to establish a quantitative dose response for clinical oral mucositis. Methods and Materials: Twelve patients undergoing radiation therapy for head-and-neck cancer were prospectively studied. Four points were chosen in separate quadrants of the oral cavity. Calculated dose distributions were generated by using AcQPlan and Eclipse treatment planning systems. MOSFET dosimeters were used to measure dose at each sampled point. Each patient underwent buccal sampling for future RNA analysis before and after the first radiation treatment at the four selected points. Clinical and functional mucositis were assessed weekly according to National Cancer Institute Common Toxicity Criteria, Version 3. Results: Maximum and average doses for sampled sites ranged from 7.4-62.3 and 3.0-54.3 Gy, respectively. A cumulative point dose of 39.1 Gy resulted in mucositis for 3 weeks or longer. Mild severity (Grade ≤ 1) and short duration (≤1 week) of mucositis were found at cumulative point doses less than 32 Gy. Polymerase chain reaction consistently was able to detect basal levels of two known radiation responsive genes. Conclusions: In our sample, cumulative doses to the oral cavity of less than 32 Gy were associated with minimal acute mucositis. A dose greater than 39 Gy was associated with longer duration of mucositis. Our technique for sampling buccal mucosa yielded sufficient cells for RNA analysis using polymerase chain reaction

  3. Towards a clinically relevant lentiviral transduction protocol for primary human CD34 hematopoietic stem/progenitor cells.

    Directory of Open Access Journals (Sweden)

    Michelle Millington

    2009-07-01

    Full Text Available Hematopoietic stem cells (HSC, in particular mobilized peripheral blood stem cells, represent an attractive target for cell and gene therapy. Efficient gene delivery into these target cells without compromising self-renewal and multi-potency is crucial for the success of gene therapy. We investigated factors involved in the ex vivo transduction of CD34(+ HSCs in order to develop a clinically relevant transduction protocol for gene delivery. Specifically sought was a protocol that allows for efficient transduction with minimal ex vivo manipulation without serum or other reagents of animal origin.Using commercially available G-CSF mobilized peripheral blood (PB CD34(+ cells as the most clinically relevant target, we systematically examined factors including the use of serum, cytokine combinations, pre-stimulation time, multiplicity of infection (MOI, transduction duration and the use of spinoculation and/or retronectin. A self-inactivating lentiviral vector (SIN-LV carrying enhanced green fluorescent protein (GFP was used as the gene delivery vehicle. HSCs were monitored for transduction efficiency, surface marker expression and cellular function. We were able to demonstrate that efficient gene transduction can be achieved with minimal ex vivo manipulation while maintaining the cellular function of transduced HSCs without serum or other reagents of animal origin.This study helps to better define factors relevant towards developing a standard clinical protocol for the delivery of SIN-LV into CD34(+ cells.

  4. The efficacy of chiropractic manipulation for back pain : Blinded review of relevant randomized clinical trials

    NARCIS (Netherlands)

    Assendelft, W. J J; Koes, B. W.; Van der Heijden, G. J M G; Bouter, L. M.

    1992-01-01

    Objective: To assess the efficacy of chiropractic for patients with back pain. Data Sources: Randomized clinical trials (RCTs) on spinal manipulation were identified with a Medline search (1966-1990), by citation tracking, and by manual examination of the relevant chiropractic reference systems

  5. Stem cell therapy for joint problems using the horse as a clinically relevant animal model

    DEFF Research Database (Denmark)

    Koch, Thomas Gadegaard; Betts, Dean H.

    2007-01-01

    of experimentally induced lesions. The horse lends itself as a good animal model of spontaneous joint disorders that are clinically relevant to similar human disorders. Equine stem cell and tissue engineering studies may be financially feasible to principal investigators and small biotechnology companies...

  6. Molecular mechanisms involved in modulation of p-glycoprotein expression from squamous cell carcinoma by low dose fractionated radiation (LDFR)

    International Nuclear Information System (INIS)

    Shajahan; Shahin; Shareef, Mohammed M.; Sathishkumar, Sabapathi; Mohiuddin, Mohammed; Ahmed, Mansoor M.; Brown, Brandee C.; Jones, Raleigh; Spring, Paul M.

    2004-01-01

    In the present study, two squamous cell carcinoma oral cavity cells (SCCOC), T-167 (p53 wild type) and T-409 (p53 mutant), were exposed to either clinically relevant dose (2 Gy), high dose (7Gy) or fractionated low dose (LDFR) (0.5 Gy x 4) and the expression of Mdr1 gene was assessed by real time RT-PCR, semiquantitative 32 P RT-PCR and luciferase reporter assay

  7. Development and application of two independent real-time PCR assays to detect clinically relevant Mucorales species.

    Science.gov (United States)

    Springer, Jan; Goldenberger, Daniel; Schmidt, Friderike; Weisser, Maja; Wehrle-Wieland, Elisabeth; Einsele, Hermann; Frei, Reno; Löffler, Jürgen

    2016-03-01

    PCR-based detection of Mucorales species could improve diagnosis of suspected invasive fungal infection, leading to a better patient outcome. This study describes two independent probe-based real-time PCR tests for detection of clinically relevant Mucorales, targeting specific fragments of the 18S and the 28S rRNA genes. Both assays have a short turnaround time, allow fast, specific and very sensitive detection of clinically relevant Mucorales and have the potential to be used as quantitative tests. They were validated on various clinical samples (fresh and formalin-fixed paraffin-embedded specimens, mainly biopsies, n = 17). The assays should be used as add-on tools to complement standard techniques; a combined approach of both real-time PCR assays has 100 % sensitivity. Genus identification by subsequent sequencing is possible for amplicons of the 18S PCR assay. In conclusion, combination of the two independent Mucorales assays described in this study, 18S and 28S, detected all clinical samples associated with proven Mucorales infection (n = 10). Reliable and specific identification of Mucorales is a prerequisite for successful antifungal therapy as these fungi show intrinsic resistance to voriconazole and caspofungin.

  8. The clinical relevance of assessing advanced glycation endproducts accumulation in diabetes

    Directory of Open Access Journals (Sweden)

    Hillebrands Jan-Luuk

    2008-10-01

    Full Text Available Abstract Cardiovascular disease is the major cause of morbidity and mortality associated with diabetes. There is increasing evidence that advanced glycation endproducts (AGEs play a pivotal role in atherosclerosis, in particular in diabetes. AGE accumulation is a measure of cumulative metabolic and oxidative stress, and may so represent the "metabolic memory". Furthermore, increased AGE accumulation is closely related to the development of cardiovascular complications in diabetes. This review article will focus on the clinical relevance of measuring AGE accumulation in diabetic patients by focusing on AGE formation, AGEs as predictors of long-term complications, and interventions against AGEs.

  9. A rule-based electronic phenotyping algorithm for detecting clinically relevant cardiovascular disease cases.

    Science.gov (United States)

    Esteban, Santiago; Rodríguez Tablado, Manuel; Ricci, Ricardo Ignacio; Terrasa, Sergio; Kopitowski, Karin

    2017-07-14

    The implementation of electronic medical records (EMR) is becoming increasingly common. Error and data loss reduction, patient-care efficiency increase, decision-making assistance and facilitation of event surveillance, are some of the many processes that EMRs help improve. In addition, they show a lot of promise in terms of data collection to facilitate observational epidemiological studies and their use for this purpose has increased significantly over the recent years. Even though the quantity and availability of the data are clearly improved thanks to EMRs, still, the problem of the quality of the data remains. This is especially important when attempting to determine if an event has actually occurred or not. We sought to assess the sensitivity, specificity, and agreement level of a codes-based algorithm for the detection of clinically relevant cardiovascular (CaVD) and cerebrovascular (CeVD) disease cases, using data from EMRs. Three family physicians from the research group selected clinically relevant CaVD and CeVD terms from the international classification of primary care, Second Edition (ICPC-2), the ICD 10 version 2015 and SNOMED-CT 2015 Edition. These terms included both signs, symptoms, diagnoses and procedures associated with CaVD and CeVD. Terms not related to symptoms, signs, diagnoses or procedures of CaVD or CeVD and also those describing incidental findings without clinical relevance were excluded. The algorithm yielded a positive result if the patient had at least one of the selected terms in their medical records, as long as it was not recorded as an error. Else, if no terms were found, the patient was classified as negative. This algorithm was applied to a randomly selected sample of the active patients within the hospital's HMO by 1/1/2005 that were 40-79 years old, had at least one year of seniority in the HMO and at least one clinical encounter. Thus, patients were classified into four groups: (1) Negative patients (2) Patients with Ca

  10. Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation

    International Nuclear Information System (INIS)

    Yang, J; Li, J S; Qin, L; Xiong, W; Ma, C-M

    2004-01-01

    The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the dimensions of the field size at the isocentre. The energy spectra of the contaminant electrons are predetermined using Monte Carlo simulations for photon beams from different clinical accelerators. A 'random creep' method is employed to derive the weight of the electron contamination source by matching Monte Carlo calculated monoenergetic photon and electron percent depth-dose (PDD) curves with measured PDD curves. We have integrated this electron contamination source into a previously developed multiple source model and validated the model for photon beams from Siemens PRIMUS accelerators. The EGS4 based Monte Carlo user code BEAM and MCSIM were used for linac head simulation and dose calculation. The Monte Carlo calculated dose distributions were compared with measured data. Our results showed good agreement (less than 2% or 2 mm) for 6, 10 and 18 MV photon beams

  11. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  12. Determination of electron clinical spectra from percentage depth dose (PDD) curves by classical simulated annealing method

    International Nuclear Information System (INIS)

    Visbal, Jorge H. Wilches; Costa, Alessandro M.

    2016-01-01

    Percentage depth dose of electron beams represents an important item of data in radiation therapy treatment since it describes the dosimetric properties of these. Using an accurate transport theory, or the Monte Carlo method, has been shown obvious differences between the dose distribution of electron beams of a clinical accelerator in a water simulator object and the dose distribution of monoenergetic electrons of nominal energy of the clinical accelerator in water. In radiotherapy, the electron spectra should be considered to improve the accuracy of dose calculation since the shape of PDP curve depends of way how radiation particles deposit their energy in patient/phantom, that is, the spectrum. Exist three principal approaches to obtain electron energy spectra from central PDP: Monte Carlo Method, Direct Measurement and Inverse Reconstruction. In this work it will be presented the Simulated Annealing method as a practical, reliable and simple approach of inverse reconstruction as being an optimal alternative to other options. (author)

  13. Parkinson’s Disease: Low-Dose Haloperidol Increases Dopamine Receptor Sensitivity and Clinical Response

    Directory of Open Access Journals (Sweden)

    Craig J. Hudson

    2014-01-01

    Full Text Available Background. It is known that ultra-low doses of haloperidol can cause dopamine supersensitivity of dopamine D2 receptors and related behaviour in animals. Objective. The objective was to determine whether a daily ultra-low dose of 40 micrograms of haloperidol could enhance the clinical action of levodopa in Parkinson’s disease patients. Method. While continuing their daily treatment with levodopa, 16 patients with Parkinson’s disease were followed weekly for six weeks. They received an add-on daily dose of 40 micrograms of haloperidol for the first two weeks only. The SPES/SCOPA scale (short scale for assessment of motor impairments and disabilities in Parkinson’s disease was administered before treatment and weekly throughout the trial. Results. The results showed a mean decrease in SPES/SCOPA scores after one week of the add-on treatment. Conclusion. SCOPA scores decreased after the addition of low-dose haloperidol to the standard daily levodopa dose. This finding is consistent with an increase in sensitivity of dopamine D2 receptors induced by haloperidol. Such treatment for Parkinson’s disease may possibly permit the levodopa dose to be reduced and, thus, delay the onset of levodopa side effects.

  14. Depth dose curves from 90Sr+90Y clinical applicators using the thermoluminescent technique

    International Nuclear Information System (INIS)

    Antonio, Patricia L.; Caldas, Linda V.E.; Oliveira, Mercia L.

    2009-01-01

    The 90 Sr+ 90 Y beta-ray sources widely used in brachytherapy applications were developed in the 1950's. Many of these sources, called clinical applicators, are still routinely used in several Brazilian radiotherapy clinics for the treatment of superficial lesions in the skin and eyes, although they are not commercialized anymore. These applicators have to be periodically calibrated, according to international recommendations, because these sources have to be very well specified in order to reach the traceability of calibration standards. In the case of beta-ray sources, the recommended quantity is the absorbed dose rate in water at a reference distance from the source. Moreover, there are other important quantities, as the depth dose curves and the source uniformity for beta-ray plaque sources. In this work, depth dose curves were obtained and studied of five dermatological applicators, using thin thermoluminescent dosimeters of CaSO 4 :Dy and phantoms of PMMA with different thicknesses (between 1.0 mm and 5.0 mm) positioned between each applicator and the TL pellets. The depth dose curves obtained presented the expected attenuation response in PMMA, and the results were compared with data obtained for a 90 Sr+ 90 Y standard source reported by the IAEA, and they were considered satisfactory. (author)

  15. Relevance of MICA and other non-HLA antibodies in clinical transplantation.

    Science.gov (United States)

    Sumitran-Holgersson, Suchitra

    2008-10-01

    The clinical importance of HLA-specific antibodies for organ allograft outcome is well established. In the past few years, there has been an increasing interest in non-HLA antigens as targets of injury in organ transplant recipients. This increased interest has been spurred by the fact that HLA-identical kidney transplants also undergo immunological rejections. Polymorphisms within non-HLA genes associated with evoking an immune response to alloantigens are currently being studied for their association with transplant outcome. Non-HLA antigens, such as the polymorphic MHC class I-related chain A (MICA), expressed on endothelial cells have been implicated in the pathogenesis of hyperacute, acute and chronic organ allograft rejections. Use of endothelial cells as targets may clarify the specificities of other clinically relevant non-HLA antibodies in graft rejections. This review summarizes past and current knowledge of the clinical importance and specificities of non-HLA antibodies, and mechanisms by which these antibodies may contribute to graft destruction in clinical transplantation. The aims of current research into the role of non-HLA antigens and their genetics in predicting outcome are to develop an improved insight into the basic science of transplantation and to develop a risk or prognostic index for use in the clinical setting. Non-HLA antibody responses are receiving increasing interest in acute and chronic rejection and specificity, affinity, and pathogenicity need to be investigated to estimate their contribution. Undoubtedly, this will continue to be an area of interest in terms of fully understanding the role of non-HLA antigens as targets of immune-mediated injury and the potential for clinical intervention.

  16. Consolidating duodenal and small bowel toxicity data via isoeffective dose calculations based on compiled clinical data.

    Science.gov (United States)

    Prior, Phillip; Tai, An; Erickson, Beth; Li, X Allen

    2014-01-01

    To consolidate duodenum and small bowel toxicity data from clinical studies with different dose fractionation schedules using the modified linear quadratic (MLQ) model. A methodology of adjusting the dose-volume (D,v) parameters to different levels of normal tissue complication probability (NTCP) was presented. A set of NTCP model parameters for duodenum toxicity were estimated by the χ(2) fitting method using literature-based tolerance dose and generalized equivalent uniform dose (gEUD) data. These model parameters were then used to convert (D,v) data into the isoeffective dose in 2 Gy per fraction, (D(MLQED2),v) and convert these parameters to an isoeffective dose at another NTCP (D(MLQED2'),v). The literature search yielded 5 reports useful in making estimates of duodenum and small bowel toxicity. The NTCP model parameters were found to be TD50(1)(model) = 60.9 ± 7.9 Gy, m = 0.21 ± 0.05, and δ = 0.09 ± 0.03 Gy(-1). Isoeffective dose calculations and toxicity rates associated with hypofractionated radiation therapy reports were found to be consistent with clinical data having different fractionation schedules. Values of (D(MLQED2'),v) between different NTCP levels remain consistent over a range of 5%-20%. MLQ-based isoeffective calculations of dose-response data corresponding to grade ≥2 duodenum toxicity were found to be consistent with one another within the calculation uncertainty. The (D(MLQED2),v) data could be used to determine duodenum and small bowel dose-volume constraints for new dose escalation strategies. Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  17. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  18. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  19. The study on clinical conditions and skin dose of upper-gastrointestinal x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Kim, Sung Chul; Ahn, Sung Min; Jang, Sang Sup

    2007-01-01

    This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipment to check the X-ray equipment and exposure factor of fluoroscopy and spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber

  20. Management of pediatric radiation dose using GE fluoroscopic equipment

    International Nuclear Information System (INIS)

    Belanger, Barry; Boudry, John

    2006-01-01

    In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an

  1. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Directory of Open Access Journals (Sweden)

    Stefano Eduardo J

    2009-04-01

    Full Text Available Abstract Background The literature supporting high-dose rate brachytherapy (HDR in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52, local recurrence (p = 0.68, or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06 rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix

  2. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Science.gov (United States)

    Viani, Gustavo A; Manta, Gustavo B; Stefano, Eduardo J; de Fendi, Ligia I

    2009-01-01

    Background The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients) of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52), local recurrence (p = 0.68), or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06) rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix cancer. PMID:19344527

  3. Biomarkers for AAA: Encouraging steps but clinical relevance still to be delivered.

    Science.gov (United States)

    Htun, Nay Min; Peter, Karlheinz

    2014-10-01

    Potential biomarkers have been investigated using proteomic studies in a variety of diseases. Some biomarkers have central roles in both diagnosis and monitoring of various disorders in clinical medicine, such as troponins, brain natriuretic peptide, and C-reactive protein. Although several biomarkers have been suggested in human abdominal aortic aneurysm (AAA), reliable markers have been lacking. In this issue, Moxon et al. [Proteomics Clin Appl. 2014, 8, 762-772] undertook a broad and systematic proteomic approach toward identification of biomarkers in a commonly used AAA mouse model (AAA created by angiotensin-II infusion). In this mouse model, apolipoprotein C1 and matrix metalloproteinase-9 were identified as novel biomarkers of stable AAA. This finding represents an important step forward, toward a clinically relevant role of biomarkers in AAA. This also encourages for further studies toward the identification of biomarkers (or their combinations) that can predict AAA progression and rupture, which would represent a major progress in AAA management and would establish an AAA biomarker as a much anticipated clinical tool. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer.A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies.Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest.Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42.This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  5. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  6. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A. Joe [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G., E-mail: PMaxim@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2017-01-01

    Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

  7. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator.

    Science.gov (United States)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A Joe; Loo, Billy W; Maxim, Peter G

    2017-01-01

    A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, "FLASH") potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  9. Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization

    Science.gov (United States)

    Wang, Chu

    Patients undergoing cardiac catheterization are potentially at risk of radiation-induced health effects from the interventional fluoroscopic X-ray imaging used throughout the clinical procedure. The amount of radiation exposure is highly dependent on the complexity of the procedure and the level of optimization in imaging parameters applied by the clinician. For cardiac catheterization, patient radiation dosimetry, for key organs as well as whole-body effective, is challenging due to the lack of fixed imaging protocols, unlike other common X-ray based imaging modalities. Pediatric patients are at a greater risk compared to adults due to their greater cellular radio-sensitivities as well as longer remaining life-expectancy following the radiation exposure. In terms of radiation dosimetry, they are often more challenging due to greater variation in body size, which often triggers a wider range of imaging parameters in modern imaging systems with automatic dose rate modulation. The overall objective of this dissertation was to develop a comprehensive method of radiation dose estimation for pediatric patients undergoing cardiac catheterization. In this dissertation, the research is divided into two main parts: the Physics Component and the Clinical Component. A proof-of-principle study focused on two patient age groups (Newborn and Five-year-old), one popular biplane imaging system, and the clinical practice of two pediatric cardiologists at one large academic medical center. The Physics Component includes experiments relevant to the physical measurement of patient organ dose using high-sensitivity MOSFET dosimeters placed in anthropomorphic pediatric phantoms. First, the three-dimensional angular dependence of MOSFET detectors in scatter medium under fluoroscopic irradiation was characterized. A custom-made spherical scatter phantom was used to measure response variations in three-dimensional angular orientations. The results were to be used as angular dependence

  10. Reliability of dose volume constraint inference from clinical data

    Science.gov (United States)

    Lutz, C. M.; Møller, D. S.; Hoffmann, L.; Knap, M. M.; Alber, M.

    2017-04-01

    Dose volume histogram points (DVHPs) frequently serve as dose constraints in radiotherapy treatment planning. An experiment was designed to investigate the reliability of DVHP inference from clinical data for multiple cohort sizes and complication incidence rates. The experimental background was radiation pneumonitis in non-small cell lung cancer and the DVHP inference method was based on logistic regression. From 102 NSCLC real-life dose distributions and a postulated DVHP model, an ‘ideal’ cohort was generated where the most predictive model was equal to the postulated model. A bootstrap and a Cohort Replication Monte Carlo (CoRepMC) approach were applied to create 1000 equally sized populations each. The cohorts were then analyzed to establish inference frequency distributions. This was applied to nine scenarios for cohort sizes of 102 (1), 500 (2) to 2000 (3) patients (by sampling with replacement) and three postulated DVHP models. The Bootstrap was repeated for a ‘non-ideal’ cohort, where the most predictive model did not coincide with the postulated model. The Bootstrap produced chaotic results for all models of cohort size 1 for both the ideal and non-ideal cohorts. For cohort size 2 and 3, the distributions for all populations were more concentrated around the postulated DVHP. For the CoRepMC, the inference frequency increased with cohort size and incidence rate. Correct inference rates  >85 % were only achieved by cohorts with more than 500 patients. Both Bootstrap and CoRepMC indicate that inference of the correct or approximate DVHP for typical cohort sizes is highly uncertain. CoRepMC results were less spurious than Bootstrap results, demonstrating the large influence that randomness in dose-response has on the statistical analysis.

  11. Clinically applied medical ethnography: relevance to cultural competence in patient care.

    Science.gov (United States)

    Engebretson, Joan

    2011-06-01

    Medical anthropology provides an excellent resource for nursing research that is relevant to clinical nursing. By expanding the understanding of ethnographic research beyond ethnicity, nurses can conduct research that explores patient's constructions and explanatory models of health and healing and how they make meaning out of chronic conditions and negotiate daily life. These findings can have applicability to culturally competent care at both the organizational or systems level, as well as in the patient/provider encounter. Individual patient care can be improved by applying ethnographic research findings to build provider expertise and then using a cultural negotiation process for individualized patient care. Copyright © 2011. Published by Elsevier Inc.

  12. Are high doses of carbidopa a concern? A randomized clinical trial in Parkinson’s disease

    Science.gov (United States)

    Brod, Lissa S.; Aldred, Jason L.; Nutt, John G.

    2013-01-01

    Background Recommended doses of carbidopa are 75–200 mg/day. Higher doses could inhibit brain aromatic amino acid decarboxylase and reduce clinical effects. Methods We compared 4-week outpatient treatments with carbidopa 75 mg and 450 mg/day administered with levodopa on the subjects’ normal schedule. After each treatment phase subjects had two 2-hour levodopa infusions. The first infusion examined the effects of carbidopa doses administered the preceding four weeks and the second infusion determined the acute effects of the two dosages of carbidopa. The antiparkinsonian effects and levodopa and carbidopa plasma concentrations were monitored during the infusions. Results Twelve subjects completed the study. Carbidopa concentrations were eight times higher after the high carbidopa phase. Area under the curve (AUC) for clinical ratings did not differ for the four levodopa infusions although AUC for plasma levodopa was modestly increased with 450 mg of carbidopa. Nine subjects reported the high carbidopa outpatient phase was associated with greater response to levodopa. Conclusion Doses of 450 mg/day of carbidopa did not reduce the responses to levodopa infusion, extending the safe range of carbidopa to 450 mg/day. PMID:22508376

  13. Clinical relevance of consolidation radiotherapy and other main therapeutic issues in primary central nervous system lymphomas treated with upfront high-dose methotrexate

    International Nuclear Information System (INIS)

    Reni, Michele; Ferreri, Andres J.M.; Guha-Thakurta, Nandita; Blay, Jean-Yves; Dell'Oro, Stefania; Biron, Pierre; Hochberg, Fred H.

    2001-01-01

    Purpose: To evaluate the optimal dose of methotrexate (MTX) and the efficacy of other drugs, intrathecal chemotherapy (CHT), and radiotherapy (RT) in primary brain lymphomas. Methods and Materials: Two hundred eighty-eight immunocompetent patients with histologically documented, previously untreated primary brain lymphomas, receiving CHT containing high-dose MTX (≥1 g/m 2 ) with or without RT were selected from 19 prospective series. The impact on survival of the MTX dose ( 2 vs.≥3 g/m 2 ), the main drugs, intrathecal CHT, and combination CHT (mono-CHT vs. poly-CHT) was assessed, according to the intention-to-treat principle. The role of post-CHT irradiation (immediate vs. delayed RT) was evaluated in 119 patients with a complete response to CHT. The whole brain and tumor bed dose ( 2 (p=0.04), thiotepa (p=0.03), and intrathecal CHT (p=0.03) improved the OS, and nitrosoureas (p 0.01) correlated with a worse survival. In multivariate analysis, limited to patients receiving MTX ≥3 g/m 2 , only the addition of cytarabine improved the OS; nitrosoureas reduced MTX efficacy. Of the 119 complete responders, 70 received immediate RT. A RT dose of ≥40 Gy to the whole brain or tumor bed did not improve OS. The 3-year OS was similar between the immediate and delayed RT groups. In multivariate analysis, RT delay had no negative impact on survival. Conclusions: MTX ≥3 g/m 2 seems to improve survival in primary brain lymphoma patients. The efficacy of additional drugs, except for cytarabine, remains unproved. Randomized trials are needed to confirm that RT withdrawal yields no detrimental effect in complete responders

  14. Patient-specific radiation dose and cancer risk for pediatric chest CT.

    Science.gov (United States)

    Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P

    2011-06-01

    To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011

  15. Development of dose audits for complex treatment techniques in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M., E-mail: stefanic@cae.cnea.gov.ar [Centro Regional de Referencia con Patrones Secundarios para Dosimetria - CNEA, Presbitero Juan Gonzalez y Aragon 15, B1802AYA Ezeiza (Argentina)

    2014-08-15

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  16. Development of dose audits for complex treatment techniques in radiotherapy

    International Nuclear Information System (INIS)

    Stefanic, A. M.; Molina, L.; Vallejos, M.; Montano, G.; Zaretzky, A.; Saravi, M.

    2014-08-01

    This work was performed in the frame of a Coordinated Research Project (CRP) with IAEA whose objective was to extend the scope of activities carried out by national TLD-based networks from dosimetry audit for rectangular radiation fields to irregular and small fields relevant to modern radiotherapy. External audit is a crucial element in QA programmes for clinical dosimetry in radiotherapy, therefore a methodology and procedures were developed and were made available for dose measurement of complex radiotherapy parameters used for cancer treatment. There were three audit steps involved in this CRP: TLD based dosimetry for irregular MLC fields for conformal radiotherapy, dosimetry in the presence of heterogeneities and 2D MLC shaped fields relevant to stereotactic radiotherapy and applicable to dosimetry for IMRT. In addition, a new development of film-based 2D dosimetry for testing dose distributions in small field geometry was included. The plan for each audit step involved a pilot study and a trial audit run with a few local hospitals. The pilot study focused on conducting and evaluation of the audit procedures with all participants. The trial audit run was the running of the audit procedures by the participants to test them with a few local radiotherapy hospitals. This work intends to provide audits which are much nearer clinical practice than previous audits as they involve significant testing of Tps methods, as well as verifications to determinate whether hospitals can correctly calculate dose delivery in radiation treatments. (author)

  17. Improved Dose Targeting for a Clinical Epithermal Neutron Capture Beam Using Optional 6Li Filtration

    International Nuclear Information System (INIS)

    Binns, Peter J.; Riley, Kent J.; Ostrovsky, Yakov; Gao Wei; Albritton, J. Raymond; Kiger, W.S.; Harling, Otto K.

    2007-01-01

    Purpose: The aim of this study was to construct a 6 Li filter and to improve penetration of thermal neutrons produced by the fission converter-based epithermal neutron beam (FCB) for brain irradiation during boron neutron capture therapy (BNCT). Methods and Materials: Design of the 6 Li filter was evaluated using Monte Carlo simulations of the existing beam line and radiation transport through an ellipsoidal water phantom. Changes in beam performance were determined using three figures of merit: (1) advantage depth (AD), the depth at which the total biologically weighted dose to tumor equals the maximum weighted dose to normal tissue; (2) advantage ratio (AR), the ratio of the integral tumor dose to that of normal tissue averaged from the surface to the AD; and (3) advantage depth dose rate (ADDR), the therapeutic dose rate at the AD. Dosimetry performed with the new filter installed provided calibration data for treatment planning. Past treatment plans were recalculated to illustrate the clinical potential of the filter. Results: The 8-mm-thick Li filter is more effective for smaller field sizes, increasing the AD from 9.3 to 9.9 cm, leaving the AR unchanged at 5.7 but decreasing the ADDR from 114 to 55 cGy min -1 for the 12 cm diameter aperture. Using the filter increases the minimum deliverable dose to deep seated tumors by up to 9% for the same maximum dose to normal tissue. Conclusions: Optional 6 Li filtration provides an incremental improvement in clinical beam performance of the FCB that could help to establish a therapeutic window in the future treatment of deep-seated tumors

  18. Dose effect relationships for radiation induced cancer: relevance of animal evidence

    International Nuclear Information System (INIS)

    Coggle, J.E.

    1982-01-01

    This article is based upon a paper which was presented at the SRP meeting on the Biological Bases of Radiation Protection Standards, October 1981. It is suggested that experimental radiation carcinogenesis data derived from animal studies will probably never provide numerical evidence of risk that is applicable to man. The uncertainties involved in any extrapolation of risk estimates from mice to men surely outweigh the uncertainties in the human epidemiological data. It is also suggested that at least in the foreseeable future animal data will not solve the perennial problem of the shape at low doses of the dose response curve for radiogenic cancer. At most the data may clarify the debate over linearity-non linearity and over the existence or otherwise of a threshold. However, the paper does suggest a very positive role for animal data in providing semi-quantitative generalisations for radiological protection concerning such variables as dose rate, radiation quality, partial body/organ exposure and in situations where the dose is received in a highly inhomogeneous fashion, e.g. the special problems of internal emitters. (author)

  19. Dose-dependent LDL-cholesterol lowering effect by plant stanol ester consumption: clinical evidence

    Directory of Open Access Journals (Sweden)

    Laitinen Kirsi

    2012-10-01

    Full Text Available Abstract Elevated serum lipids are linked to cardiovascular diseases calling for effective therapeutic means to reduce particularly LDL-cholesterol (LDL-C levels. Plant stanols reduce levels of LDL-C by partly blocking cholesterol absorption. Accordingly the consumption of foods with added plant stanols, typically esterified with vegetable oil fatty acids in commercial food products, are recommended for lowering serum cholesterol levels. A daily intake of 1.5 to 2.4 g of plant stanols has been scientifically evaluated to lower LDL-C by 7 to 10% in different populations, ages and with different diseases. Based on earlier studies, a general understanding is that no further reduction may be achieved in intakes in excess of approximately 2.5 g/day. Recent studies however suggest that plant stanols show a continuous dose–response effect in serum LDL-C lowering. This review discusses the evidence for a dose-effect relationship between plant stanol ester consumption and reduction of LDL-C concentrations with daily intakes of plant stanols of 4 g/day or more. We identified five such studies and the overall data demonstrate a linear dose-effect relationship with the most pertinent LDL-Cholesterol lowering outcome, 18%, achieved by a daily intake of 9 to 10 g of plant stanols. Along with reduction in LDL-C, the studies demonstrated a decrease in cholesterol absorption markers, the serum plant sterol to cholesterol ratios, by increasing the dose of plant stanol intake. None of the studies with daily intakes up to 10 g of plant stanols reported adverse clinical or biochemical effects from plant stanols. In a like manner, the magnitude of decrease in serum antioxidant vitamins was not related to the dose of plant stanols consumed and the differences between plant stanol ester consumers and controls were minor and insignificant or nonexisting. Consumption of plant stanols in high doses is feasible as a range of food products are commercially available for

  20. Low-dose single acquisition rest {sup 99m}Tc/stress {sup 201}Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Thomas [RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen (Germany); Backus, Barbra E.; Romijn, R.Leo [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Wieczorek, Herfried [Philips Research, Eindhoven (Netherlands); Verzijlbergen, J.F. [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands)

    2014-03-15

    We developed and tested a single acquisition rest {sup 99m}Tc-sestamibi/stress {sup 201}Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress {sup 99m}Tc and rest {sup 99m}Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected {sup 201}Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the {sup 201}Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and {sup 99m}Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the {sup 99m}Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients

  1. Clinical and symptomatological study of pigs subjected to a lethal dose of integral gamma irradiation

    International Nuclear Information System (INIS)

    Vaiman, M.; Guenet, J.-L.; Maas, J.; Nizza, P.

    1966-05-01

    Results are reported from a clinical and haematological study on a Corsican species of pigs wholly exposed to an approximately lethal dose of γ radiation. The aim of this work was to examine the changes in the irradiation syndrome of irradiation for pigs to make it thus possible to devise further experiments, in particular in the therapeutic field. The dose received was 285 rads (measured as the absorption in the vertical antero-posterior medial plane). Data are presented on cyto-haematological changes in the blood circulating immediately after irradiation, and followed up to death, and changes in the medullary cytology after irradiation. The clinical picture of lethal radiation injury in swine is described. (authors) [fr

  2. Review of proton pump inhibitors for the initial treatment of heartburn: is there a dose ceiling effect?

    Science.gov (United States)

    Kushner, Pamela R; Peura, David A

    2011-05-01

    Proton pump inhibitors (PPIs) are widely used in clinical practice. However, concerns have been expressed about their long-term use, particularly with regard to bone health, Clostridium difficile infections, and drug interactions with platelet aggregation inhibitors. There has been limited guidance for clinicians concerning appropriate dose selection of PPIs for the initial treatment of heartburn. This review explored whether published clinical trials provide evidence of a ceiling above which higher PPI doses do not provide additional clinical benefit over the lowest approved dose. All articles of randomized, controlled clinical trials in nonerosive gastroesophageal reflux disease (GERD) in which the effects of two or more doses of the same PPI on symptomatic relief of heartburn were quantified as a study endpoint were identified and analyzed through PubMed searches up to the end of September 2010. The majority of trials evaluated provided no evidence that higher PPI doses were superior to the lowest approved dose for the initial treatment of heartburn. There were no clinically relevant findings with respect to dose dependence and safety outcomes in these studies. Efficacy outcomes from the trials suggest there may be a dose ceiling effect and highlight the need for further research on the use of the lowest effective PPI doses as an appropriate strategy in the initial treatment of uncomplicated heartburn. Observational studies and some meta-analyses have suggested that long-term PPI pharmacotherapy might be associated with safety concerns, which necessitate the periodic evaluation of therapeutic benefit in terms of symptom resolution and regimen tolerability. However, evidence to date suggests that use of the lowest effective dose for the indication is not associated with significant adverse events, particularly in the short term. Clinical practice suggests that patients requiring long-term treatment should be maintained on the lowest dose necessary to control

  3. Taijin Kyofusho and Social Anxiety and their clinical relevance in Indonesia and Switzerland

    OpenAIRE

    Vriends, Noortje; Pfaltz, Monique C.; Novianti, Peppy; Hadiyono, Johana

    2013-01-01

    Background: Taijin Kyofusho (TKS) is an interpersonal fear to offend others and is defined by DSM-IV as a culturally bound syndrome that occurs in Japan and Korea. Recently, cases with TKS have also been recognized in other cultures. The present questionnaire study investigated self-report TKS symptoms and social anxiety symptoms, and their clinical relevance in an Indonesian and Swiss sample. It also investigated if self-construal is associated with TKS and social anxiety, and if self-constr...

  4. Taijin Kyofusho and Social Anxiety and Their Clinical Relevance in Indonesia and Switzerland

    OpenAIRE

    Vriends, N.; Pfaltz, M. C.; Novianti, P.; Hadiyono, J.

    2013-01-01

    Background: Taijin Kyofusho Scale (TKS) is an interpersonal fear to offend others and is defined by Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) as a culturally bound syndrome that occurs in Japan and Korea. Recently, cases with TKS have also been recognized in other cultures. The present questionnaire study investigated self-report TKS symptoms and social anxiety symptoms, and their clinical relevance in an Indonesian and Swiss sample. It also investigated whether self-cons...

  5. Taijin Kyofusho and Social Anxiety and their clinical relevance in Indonesia and Switzerland

    OpenAIRE

    Noortje eVriends; Noortje eVriends; Monique C Pfaltz; Peppy eNovianti; Johana eHadiyono

    2013-01-01

    Background: Taijin Kyofusho (TKS) is an interpersonal fear to offend others and is defined by DSM-IV as a culturally bound syndrome that occurs in Japan and Korea. Recently, cases with TKS have also been recognized in other cultures. The present questionnaire study investigated self-report TKS symptoms and social anxiety symptoms, and their clinical relevance in an Indonesian and Swiss sample. It also investigated if self-construal is associated with TKS and social anxiety, and if self-const...

  6. Isolation, speciation, and antibiogram of clinically relevant non-diphtherial Corynebacteria (Diphtheroids

    Directory of Open Access Journals (Sweden)

    B S Reddy

    2012-01-01

    Full Text Available Purpose: Coryneform or the non-diphtherial Corynebacterium species largely remains a neglected group with the traditional consideration of these organisms as contaminants. This concept, however, is slowly changing in the light of recent observations. This study has been done to find out the species distribution and antibiogram of various members of the clinically relevant Coryneform group, isolated from various clinical materials. Materials and Methods: One hundred and fourteen non-duplicate isolates of diphtheroids from various clinical isolates were selected for the study. The isolates were identified to the species level by using a battery of tests; and antimicrobial susceptibility was tested by using a combination of Clinical and Laboratory Standards Institute (CLSI and the British Society for Antimicrobial Chemotherapy (BSAC guidelines, in the absence of definitive CLSI guidelines. Results: Corynebacterium amycolatum was the predominant species (35.9% in our series followed by the CDC Group G organisms (15.7%. Each of the remaining 19 species comprised of less than 10% of the isolates. More than half the total isolates were resistant to the penicillins, erythromycin, and clindamycin; while excellent activity (all the strains being susceptible was shown by vancomycin, linezolid, and tigecycline. Chloramphenicol and tetracycline also had good activity in inhibiting more than 80% of the isolates. Multiply drug resistance was exhibited by all the species. Conclusion: This study was an attempt to establish the clinical significance of coryneform organisms. The high level of resistance shown by this group to some of the common antibacterial agents highlights the importance of processing these isolates in select conditions to guide the clinicians towards an appropriate therapy.

  7. Clinical outcomes with alternative dosing strategies for piperacillin/tazobactam: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Hui Yang

    Full Text Available A better dosing strategy can improve clinical outcomes for patients. We sought to compare the extended or continuous infusion with conventional intermittent infusion of piperacillin/tazobactam, investigating which approach is better and worthy of recommendation for clinical use.Articles were gathered from PubMed, Web of Science, ProQuest, Science Direct, Cochrane, two Chinese literature databases (CNKI, Wan Fang Data and related ICAAC and ACCP conferences. Randomized controlled and observational studies that compared extended or continuous infusion with conventional intermittent infusion of piperacillin/tazobactam were identified from the databases above and analyzed. Two reviewers independently extracted and investigated the data. A meta-analysis was performed using Revman 5.2 software. The quality of each study was assessed. Sensitivity analysis and publication bias were evaluated.Five randomized controlled trials and nine observational studies were included in this study. All included studies had high quality and no publication bias was found. Compared to the conventional intermittent infusion approach, the extended or continuous infusion group had a significantly higher clinical cure rate (OR 1.88, 95% CI 1.29-2.73, P = 0.0009 and a lower mortality rate (OR 0.67, 95% CI 0.50-0.89, P = 0.005. No statistical difference was observed for bacteriologic cure (OR 1.40, 95% CI 0.82-2.37, P = 0.22 between the two dosing regimens. The sensitivity analysis showed the results were stable.Our systematic review and meta-analysis suggested that the extended or continuous infusion strategy of piperacillin/tazobactam should be recommended for clinical use considering its higher clinical cure rate and lower mortality rate in comparison with conventional intermittent strategy. Data from this study could be extrapolated for other β-lactam antimicrobials. Therefore, this dosing strategy could be considered in clinical practice.

  8. Patient-reported symptoms during radiotherapy : Clinically relevant symptom burden in patients treated with palliative and curative intent.

    Science.gov (United States)

    Körner, Philipp; Ehrmann, Katja; Hartmannsgruber, Johann; Metz, Michaela; Steigerwald, Sabrina; Flentje, Michael; van Oorschot, Birgitt

    2017-07-01

    The benefits of patient-reported symptom assessment combined with integrated palliative care are well documented. This study assessed the symptom burden of palliative and curative-intent radiation oncology patients. Prior to first consultation and at the end of RT, all adult cancer patients planned to receive fractionated percutaneous radiotherapy (RT) were asked to answer the Edmonton Symptom Assessment Scale (ESAS; nine symptoms from 0 = no symptoms to 10 = worst possible symptoms). Mean values were used for curative vs. palliative and pre-post comparisons, and the clinical relevance was evaluated (symptom values ≥ 4). Of 163 participating patients, 151 patients (90.9%) completed both surveys (116 curative and 35 palliative patients). Before beginning RT, 88.6% of palliative and 72.3% of curative patients showed at least one clinically relevant symptom. Curative patients most frequently named decreased general wellbeing (38.6%), followed by tiredness (35.0%), anxiety (32.4%), depression (30.0%), pain (26.3%), lack of appetite (23.5%), dyspnea (17.8%), drowsiness (8.0%) and nausea (6.1%). Palliative patients most frequently named decreased general wellbeing (62.8%), followed by pain (62.8%), tiredness (60.0%), lack of appetite (40.0%), anxiety (38.0%), depression (33.3%), dyspnea (28.5%), drowsiness (25.7%) and nausea (14.2%). At the end of RT, the proportion of curative and palliative patients with a clinically relevant symptom had increased significantly to 79.8 and 91.4%, respectively; whereas the proportion of patients reporting clinically relevant pain had decreased significantly (42.8 vs. 62.8%, respectively). Palliative patients had significantly increased tiredness. Curative patients reported significant increases in pain, tiredness, nausea, drowsiness, lack of appetite and restrictions in general wellbeing. Assessment of patient-reported symptoms was successfully realized in radiation oncology routine. Overall, both groups showed a high symptom

  9. Patient-reported symptoms during radiotherapy. Clinically relevant symptom burden in patients treated with palliative and curative intent

    International Nuclear Information System (INIS)

    Koerner, Philipp; Ehrmann, Katja; Hartmannsgruber, Johann; Metz, Michaela; Steigerwald, Sabrina; Flentje, Michael; Oorschot, Birgitt van

    2017-01-01

    The benefits of patient-reported symptom assessment combined with integrated palliative care are well documented. This study assessed the symptom burden of palliative and curative-intent radiation oncology patients. Prior to first consultation and at the end of RT, all adult cancer patients planned to receive fractionated percutaneous radiotherapy (RT) were asked to answer the Edmonton Symptom Assessment Scale (ESAS; nine symptoms from 0 = no symptoms to 10 = worst possible symptoms). Mean values were used for curative vs. palliative and pre-post comparisons, and the clinical relevance was evaluated (symptom values ≥ 4). Of 163 participating patients, 151 patients (90.9%) completed both surveys (116 curative and 35 palliative patients). Before beginning RT, 88.6% of palliative and 72.3% of curative patients showed at least one clinically relevant symptom. Curative patients most frequently named decreased general wellbeing (38.6%), followed by tiredness (35.0%), anxiety (32.4%), depression (30.0%), pain (26.3%), lack of appetite (23.5%), dyspnea (17.8%), drowsiness (8.0%) and nausea (6.1%). Palliative patients most frequently named decreased general wellbeing (62.8%), followed by pain (62.8%), tiredness (60.0%), lack of appetite (40.0%), anxiety (38.0%), depression (33.3%), dyspnea (28.5%), drowsiness (25.7%) and nausea (14.2%). At the end of RT, the proportion of curative and palliative patients with a clinically relevant symptom had increased significantly to 79.8 and 91.4%, respectively; whereas the proportion of patients reporting clinically relevant pain had decreased significantly (42.8 vs. 62.8%, respectively). Palliative patients had significantly increased tiredness. Curative patients reported significant increases in pain, tiredness, nausea, drowsiness, lack of appetite and restrictions in general wellbeing. Assessment of patient-reported symptoms was successfully realized in radiation oncology routine. Overall, both groups showed a high symptom burden

  10. Identification and content validation of wound therapy clinical endpoints relevant to clinical practice and patient values for FDA approval. Part 1. Survey of the wound care community.

    Science.gov (United States)

    Driver, Vickie R; Gould, Lisa J; Dotson, Peggy; Gibbons, Gary W; Li, William W; Ennis, William J; Kirsner, Robert S; Eaglstein, William H; Bolton, Laura L; Carter, Marissa J

    2017-05-01

    Wounds that exhibit delayed healing add extraordinary clinical, economic, and personal burdens to patients, as well as to increasing financial costs to health systems. New interventions designed to ease such burdens for patients with cancer, renal, or ophthalmologic conditions are often cleared for approval by the U.S. Food and Drug Administration (FDA) using multiple endpoints but the requirement of complete healing as a primary endpoint for wound products impedes FDA clearance of interventions that can provide other clinical or patient-centered benefits for persons with wounds. A multidisciplinary group of wound experts undertook an initiative, in collaboration with the FDA, to identify and content validate supporting FDA criteria for qualifying wound endpoints relevant to clinical practice (CP) and patient-centered outcomes (PCO) as primary outcomes in clinical trials. As part of the initiative, a research study was conducted involving 628 multidisciplinary expert wound clinicians and researchers from 4 different groups: the interdisciplinary core advisory team; attendees of the Spring 2015 Symposium on Advanced Wound Care (SAWC); clinicians employed by a national network of specialty clinics focused on comprehensive wound care; and Association for the Advancement of Wound Care (AAWC) and Wound Healing Society (WHS) members who had not previously completed the survey. The online survey assessed 28 literature-based wound care endpoints for their relevance and importance to clinical practice and clinical research. Fifteen of the endpoints were evaluated for their relevance to improving quality of life. Twenty-two endpoints had content validity indexes (CVI) ≥ 0.75, and 15 were selected as meriting potential inclusion as additional endpoints for FDA approval of future wound care interventions. This study represents an important first step in identifying and validating new measurable wound care endpoints for clinical research and practice and for regulatory

  11. Magnetic resonance only workflow and validation of dose calculations for radiotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Lübeck Christiansen, Rasmus; Jensen, Henrik R.; Brink, Carsten

    2017-01-01

    Background: Current state of the art radiotherapy planning of prostate cancer utilises magnetic resonance (MR) for soft tissue delineation and computed tomography (CT) to provide an electron density map for dose calculation. This dual scan workflow is prone to setup and registration error....... This study evaluates the feasibility of an MR-only workflow and the validity of dose calculation from an MR derived pseudo CT. Material and methods: Thirty prostate cancer patients were CT and MR scanned. Clinical treatment plans were generated on CT using a single 18 MV arc volumetric modulated arc therapy...... was successfully delivered to one patient, including manually performed daily IGRT. Conclusions: Median gamma pass rates were high for pseudo CT and proved superior to uniform density. Local differences in dose calculations were concluded not to have clinical relevance. Feasibility of the MR-only workflow...

  12. Evaluation of exome filtering techniques for the analysis of clinically relevant genes.

    Science.gov (United States)

    Kernohan, Kristin D; Hartley, Taila; Alirezaie, Najmeh; Robinson, Peter N; Dyment, David A; Boycott, Kym M

    2018-02-01

    A significant challenge facing clinical translation of exome sequencing is meaningful and efficient variant interpretation. Each exome contains ∼500 rare coding variants; laboratories must systematically and efficiently identify which variant(s) contribute to the patient's phenotype. In silico filtering is an approach that reduces analysis time while decreasing the chances of incidental findings. We retrospectively assessed 55 solved exomes using available datasets as in silico filters: Online Mendelian Inheritance in Man (OMIM), Orphanet, Human Phenotype Ontology (HPO), and Radboudumc University Medical Center curated panels. We found that personalized panels produced using HPO terms for each patient had the highest success rate (100%), while producing considerably less variants to assess. HPO panels also captured multiple diagnoses in the same individual. We conclude that custom HPO-derived panels are an efficient and effective way to identify clinically relevant exome variants. © 2017 Wiley Periodicals, Inc.

  13. Therapeutic doses of doxorubicin induce premature senescence of human mesenchymal stem cells derived from menstrual blood, bone marrow and adipose tissue.

    Science.gov (United States)

    Kozhukharova, Irina; Zemelko, Victoria; Kovaleva, Zoya; Alekseenko, Larisa; Lyublinskaya, Olga; Nikolsky, Nikolay

    2018-03-01

    Doxorubicin (Dox) is an effective anticancer drug with known activity against a wide spectrum of malignancies, hematologic malignancies in particular. Despite extensive clinical use, the mechanisms of its side effects and negative action on normal cells remain under study. The aim of this study was to investigate the effect of Dox on cultured human mesenchymal stem cells (MSCs) derived from menstrual blood (eMSCs), bone marrow (BMSCs) and adipose tissue (AMSCs). Dox treatment in high doses decreased the survival of MSCs in a dose-dependent manner. Clinically relevant low doses of Dox induced premature senescence of eMSCs, BMSCs and AMSCs, but did not kill the cells. Dox caused cell cycle arrest and formation of γ-H2AX foci, and increased the number of SA-β-gal-positive cells. BMSCs entered premature senescence earlier than other MSCs. It has been reported that neural-like cells differentiated from MSCs of various origins are more sensitive to Dox than their parent cells. Dox-treated differentiated MSCs exhibited lower viability and earlier generation of γ-H2AX foci. Dox administration inhibited secretory activity in neural-like cells. These findings suggest that a clinically relevant Dox dose damages cultured MSCs, inducing their premature senescence. MSCs are more resistant to this damage than differentiated cells.

  14. Research design considerations for single-dose analgesic clinical trials in acute pain

    DEFF Research Database (Denmark)

    Cooper, Stephen A; Desjardins, Paul J; Turk, Dennis C

    2016-01-01

    This article summarizes the results of a meeting convened by the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT) on key considerations and best practices governing the design of acute pain clinical trials. We discuss the role of early phase clinical trials......, including pharmacokinetic-pharmacodynamic (PK-PD) trials, and the value of including both placebo and active standards of comparison in acute pain trials. This article focuses on single-dose and short-duration trials with emphasis on the perioperative and study design factors that influence assay...... sensitivity. Recommendations are presented on assessment measures, study designs, and operational factors. Although most of the methodological advances have come from studies of postoperative pain after dental impaction, bunionectomy, and other surgeries, the design considerations discussed are applicable...

  15. Survey on patient doses in cardiology in Latin America. Criteria for high skin doses follow up

    International Nuclear Information System (INIS)

    Duran, Ariel; Duro, Ivanna; Lopez, Leonardo; Ramirez, Alfredo; Herrera, Carlos; Navarro, Joaquin; Rivarola, Carlos; Lopez, Jose A.

    2008-01-01

    Full text: As part of the International Action Plan for Protection of Patients and supporting by the IAEA, a survey on patient doses in fluoroscopy guided procedures in cardiology in Latin America has been conducted since 2006. One of the objectives of the survey was to set criteria for the identification and evaluation of high skin doses in a certain number of patients to recommend a clinical follow up for potential radiation injuries (more than 3 Gy at the skin). The used methodology for the survey was initiated with two dedicated workshops held in Santiago de Chile (2005) and San Jose de Costa Rica (2007) involving relevant cardiologists from 15 different Latin American Countries. Some sessions were also attended by experts from the Regulatory and Health Authorities. Standardized forms to collect demographic and patient dosimetric data were agreed. Considering that most of the involved centres had still not dosimeters installed in the cardiology x-ray systems, it was agreed to collect data on fluoroscopy time and total number of cine frames per procedure. Relevant factors influencing radio sensitivity of the skin were also collected. Data from 10 countries representing a sample of 709 patients were received during the first year. Procedures included were diagnostic (DG) (coronary angiography and electrophysiology studies), therapeutic (TH) (percutaneous transluminal coronary angioplasties, cardiac ablations and valvuloplasties) or including both DG and TH. A total of 26 patients (3.7%) were selected for potential high skin doses. Initial considered criteria for selection were more than 30 minutes of fluoroscopy, more than 3,000 cine frames per procedure or patients with more than 100 kg of weight. Maximum reported values were 72 minutes and 8,100 frames. In addition, 5 of these patients were diabetic, 6 have previous fluoroscopy procedures and 5 were over 95 kg. The percentage of selected cases for clinical follow up derived from potential skin injuries seem

  16. Clinical benefit of fixed-dose dual bronchodilation with glycopyrronium and indacaterol once daily in patients with chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Ulrik, Charlotte Suppli

    2014-01-01

    BACKGROUND AND AIM: Long-acting bronchodilators are the preferred option for maintenance therapy of patients with chronic obstructive pulmonary disease (COPD). The aim of this review is to provide an overview of the clinical studies evaluating the clinical efficacy of the once-daily fixed-dose du...... for chronic Obstructive Lung Disease [GOLD] spirometric criteria). Furthermore, a very recent study has shown that fixed-dose indacaterol/glycopyrronium improves exercise endurance time compared with placebo, although no significant difference was observed between fixed-dose indacaterol...

  17. Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning

    International Nuclear Information System (INIS)

    Moore, K L; Appenzoller, L M; Tan, J; Michalski, J M; Thorstad, W L; Mutic, S

    2014-01-01

    True quality control (QC) of the planning process requires quantitative assessments of treatment plan quality itself, and QC in IMRT has been stymied by intra-patient anatomical variability and inherently complex three-dimensional dose distributions. In this work we describe the development of an automated system to reduce clinical IMRT planning variability and improve plan quality using mathematical models that predict achievable OAR DVHs based on individual patient anatomy. These models rely on the correlation of expected dose to the minimum distance from a voxel to the PTV surface, whereby a three-parameter probability distribution function (PDF) was used to model iso-distance OAR subvolume dose distributions. DVH models were obtained by fitting the evolution of the PDF with distance. Initial validation on clinical cohorts of 40 prostate and 24 head-and-neck plans demonstrated highly accurate model-based predictions for achievable DVHs in rectum, bladder, and parotid glands. By quantifying the integrated difference between candidate DVHs and predicted DVHs, the models correctly identified plans with under-spared OARs, validated by replanning all cases and correlating any realized improvements against the predicted gains. Clinical implementation of these predictive models was demonstrated in the PINNACLE treatment planning system by use of existing margin expansion utilities and the scripting functionality inherent to the system. To maintain independence from specific planning software, a system was developed in MATLAB to directly process DICOM-RT data. Both model training and patient-specific analyses were demonstrated with significant computational accelerations from parallelization.

  18. European Academy of Allergy and Clinical Immunology task force report on 'dose-response relationship in allergen-specific immunotherapy'.

    Science.gov (United States)

    Calderón, M A; Larenas, D; Kleine-Tebbe, J; Jacobsen, L; Passalacqua, G; Eng, P A; Varga, E M; Valovirta, E; Moreno, C; Malling, H J; Alvarez-Cuesta, E; Durham, S; Demoly, P

    2011-10-01

    For a century, allergen-specific immunotherapy (SIT) has proven to be an effective treatment for allergic rhinitis, asthma, and insect sting allergy. However, as allergen doses are frequently adapted to the individual patient, there are few data on dose-response relationship in SIT. Allergen products for SIT are being increasingly required to conform to regulatory requirements for human medicines, which include the need to demonstrate dose-dependent effects. This report, produced by a Task Force of the EAACI Immunotherapy Interest Group, evaluates the currently available data on dose-response relationships in SIT and aims to provide recommendations for the design of future studies. Fifteen dose-ranging studies fulfilled the inclusion criteria and twelve reported a dose-response relationship for clinical efficacy. Several studies also reported a dose-response relationship for immunological and safety endpoints. Due to the use of different reference materials and methodologies for the determination of allergen content, variations in study design, and choice of endpoints, no comparisons could be made between studies and, as a consequence, no general dosing recommendations can be made. Despite recently introduced guidelines on the standardization of allergen preparations and study design, the Task Force identified a need for universally accepted standards for the measurement of allergen content in SIT preparations, dosing protocols, and selection of clinical endpoints to enable dose-response effects to be compared across studies. © 2011 John Wiley & Sons A/S.

  19. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2016-10-15

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  20. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    International Nuclear Information System (INIS)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian

    2016-01-01

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  1. Clinical relevance and scope of accidental extracoronary findings in coronary computed tomography angiography: A cardiac versus thoracic FOV study

    International Nuclear Information System (INIS)

    Aglan, Iman; Jodocy, Daniel; Hiehs, Stefan; Soegner, Peter; Frank, Renate; Haberfellner, Berhard; Klauser, Andrea; Jaschke, Werner; Feuchtner, Gudrun M.

    2010-01-01

    Objective: To assess the spectrum and clinical relevance of extracoronary findings in coronary CT angiography (CCTA), and to compare a small (cardiac) field of view (FOV) to a large (thoracic) FOV setting. Material and methods: 1084 consecutive patients (mean 57 years) with low-to-intermediate risk of coronary artery disease were enrolled. 542 CCTA scans were interpreted with small FOV (160-190 mm 2 ) encompassing the cardiac region. In another 542 CCTA (patients matched for age and gender), read-out of an additional full FOV (>320 mm 2 ) covering the thorax was performed. Clinical relevance of extracoronary findings was considered as either 'significant' or 'non-significant'. 'Significant' findings were subclassified as either score 1: findings necessitating immediate therapeutic actions, or score 2: findings with undoubted clinical or prognostic relevance, requiring clinical awareness, follow-up or further investigations (non-urgent). 'Non-significant' findings were assigned to either score 3: findings not requiring follow-up or further tests, or as score 4: irrelevant incidental findings. Results: Significantly more patients with extracoronary findings were identified by using a full FOV with 43.2% (234/542) compared to a small FOV with 33.6% (182/542) (p = 0.001). Similarly, a higher total number of extracoronary findings (n = 394) was found on full FOV compared to small FOV (n = 250) (p 2 aortic valve orifice area. Conclusions: The interpretation of extracoronary findings on CCTA scans is mandatory given high prevalence of clinically significant findings by using a full 'thoracic' FOV.

  2. Dose distribution and clinical response of glioblastoma treated with boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)], E-mail: mhide-m@gk9.so-net.ne.jp; Yamamoto, T. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Kumada, H. [Japan Atomic Energy Agency, Shirakatashirane 2-4, Tokai (Japan); Nakai, K.; Shirakawa, M.; Tsurubuchi, T.; Matsumura, A. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)

    2009-07-15

    The dose distribution and failure pattern after treatment with the external beam boron neutron capture therapy (BNCT) protocol were retrospectively analyzed. BSH (5 g/body) and BPA (250 mg/kg) based BNCT was performed in eight patients with newly diagnosed glioblastoma. The gross tumor volume (GTV) and clinical target volume (CTV)-1 were defined as the residual gadolinium-enhancing volume. CTV-2 and CTV-3 were defined as GTV plus a margin of 2 and 3 cm, respectively. As additional photon irradiation, a total X-ray dose of 30 Gy was given to the T2 high intensity area on MRI. Five of the eight patients were alive at analysis for a mean follow-up time of 20.3 months. The post-operative median survival time of the eight patients was 27.9 months (95% CI=21.0-34.8). The minimum tumor dose of GTV, CTV-2, and CTV-3 averaged 29.8{+-}9.9, 15.1{+-}5.4, and 12.4{+-}2.9 Gy, respectively. The minimum tumor non-boron dose of GTV, CTV-2, and CTV-3 averaged 2.0{+-}0.5, 1.3{+-}0.3, and 1.1{+-}0.2 Gy, respectively. The maximum normal brain dose, skin dose, and average brain dose were 11.4{+-}1.5, 9.6{+-}1.4, and 3.1{+-}0.4 Gy, respectively. The mean minimum dose at the failure site in cases of in-field recurrence (IR) and out-field recurrence (OR) was 26.3{+-}16.7 and 14.9 GyEq, respectively. The calculated doses at the failure site were at least equal to the tumor control doses which were previously reported. We speculate that the failure pattern was related to an inadequate distribution of boron-10. Further improvement of the microdistribution of boron compounds is expected, and may improve the tumor control by BNCT.

  3. Dosimetric and Clinical Analysis of Spatial Distribution of the Radiation Dose in Gamma Knife Radiosurgery for Vestibular Schwannoma

    International Nuclear Information System (INIS)

    Massager, Nicolas; Lonneville, Sarah; Delbrouck, Carine; Benmebarek, Nadir; Desmedt, Françoise; Devriendt, Daniel

    2011-01-01

    Objectives: We investigated variations in the distribution of radiation dose inside (dose inhomogeneity) and outside (dose falloff) the target volume during Gamma Knife (GK) irradiation of vestibular schwannoma (VS). We analyzed the relationship between some parameters of dose distribution and the clinical and radiological outcome of patients. Methods and Materials: Data from dose plans of 203 patients treated for a vestibular schwannoma by GK C using same prescription dose (12 Gy at the 50% isodose) were collected. Four different dosimetric indexes were defined and calculated retrospectively in all plannings on the basis of dose–volume histograms: Paddick conformity index (PI), gradient index (GI), homogeneity index (HI), and unit isocenter (UI). The different measures related to distribution of the radiation dose were compared with hearing and tumor outcome of 203 patients with clinical and radiological follow-up of minimum 2 years. Results: Mean, median, SD, and ranges of the four indexes of dose distribution analyzed were calculated; large variations were found between dose plans. We found a high correlation between the target volume and PI, GI, and UI. No significant association was found between the indexes of dose distribution calculated in this study and tumor control, tumor volume shrinkage, hearing worsening, loss of functional hearing, or complete hearing loss at last follow-up. Conclusions: Parameters of distribution of the radiation dose during GK radiosurgery for VS can be highly variable between dose plans. The tumor and hearing outcome of patients treated is not significantly related to these global indexes of dose distribution inside and around target volume. In GK radiosurgery for VS, the outcome seems more to be influenced by local radiation dose delivered to specific structures or volumes than by global dose gradients.

  4. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  5. Polanyi's tacit knowing and the relevance of epistemology to clinical medicine.

    Science.gov (United States)

    Henry, Stephen G

    2010-04-01

    Most clinicians take for granted a simple, reductionist understanding of medical knowledge that is at odds with how they actually practice medicine; routine medical decisions incorporate more complicated kinds of information than most standard accounts of medical reasoning suggest. A better understanding of the structure and function of knowledge in medicine can lead to practical improvements in clinical medicine. This understanding requires some familiarity with epistemology, the study of knowledge and its structure, in medicine. Michael Polanyi's theory of tacit knowing is advanced as the basis for developing a more accurate understanding of medical knowledge. Tacit knowing, which explores the taken-for-granted background knowledge that underlies all human knowing, is explained in detail with a focus on its relevance for clinical medicine. The implications of recognizing tacit knowing in medicine and medical decisions are discussed. These include the ability to explain the importance of the clinical encounter in medical practice, mechanisms for analysing patient and doctor as persons, and the need for humility given the uncertainty that the tacit dimension injects into all medical decisions. This more robust medical epistemology allows clinicians to better articulate the nature and importance of patient-centred care, to avoid pitfalls inherent in reductionist approaches to medical knowledge, and to think more clearly about the relationships between medicine and health care at the individual and population levels.

  6. A Bridge between Two Cultures: Uncovering the Chemistry Concepts Relevant to the Nursing Clinical Practice

    Science.gov (United States)

    Brown, Corina E.; Henry, Melissa L. M.; Barbera, Jack; Hyslop, Richard M.

    2012-01-01

    This study focused on the undergraduate course that covers basic topics in general, organic, and biological (GOB) chemistry at a mid-sized state university in the western United States. The central objective of the research was to identify the main topics of GOB chemistry relevant to the clinical practice of nursing. The collection of data was…

  7. The outcome of clinical parameters in adults with severe Type I Gaucher disease using very low dose enzyme replacement therapy.

    Science.gov (United States)

    Wilson, Callum; Spearing, Ruth; Teague, Lochie; Robertson, Patsy; Blacklock, Hilary

    2007-01-01

    Enzyme replacement therapy is now well established as the treatment of choice in Type I Gaucher disease. Historically higher dosage regimens have been used in preference to lower doses despite the little clinical evidence in the way of large controlled clinical trials to support this. Moreover, the extraordinary cost of therapy means that not all eligible patients are able to be treated at the higher dose. Twelve type I adult patients with relatively severe disease were commenced on a very low dose of 7.5U of alglucerase/imiglucerase per kg every two weeks (initially given thrice weekly and later weekly). Follow-up 5 year data reveal a good visceral and haematological response with outcomes consistent with recently published treatment guidelines. Satisfactory clinical and radiological skeletal improvement was also demonstrated in most patients. Three patients had an inadequate overall skeletal response to therapy. Biomarkers also steadily improved although perhaps not quite at the same rate as that seen in higher doses. Very low dose enzyme replacement therapy may be appropriate for adult type I Gaucher patients with mild-moderate skeletal disease.

  8. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  9. [The relevance of clinical risk management].

    Science.gov (United States)

    Gulino, Matteo; Vergallo, Gianluca Montanari; Frati, Paola

    2011-01-01

    Medical activity includes a risk of possible injury or complications for the patients, that should drive the Health Care Institutions to introduce and/ or improve clinical Risk management instruments. Although Italy is still lacking a National project of Clinical Risk Management, a number of efforts have been made by different Italian Regions to introduce instruments of risk management. In addition, most of National Health Care Institutions include actually a Department specifically in charge to manage the clinical risk. Despite the practical difficulties, the results obtained until now suggest that the risk management may represent a useful instrument to contribute to the reduction of errors in clinical conduct. Indeed, the introduction of adequate instruments of prevention and management of clinical risk may help to ameliorate the quality of health care Institution services.

  10. Exhaled nitric oxide measure using multiple flows in clinically relevant subgroups of COPD

    DEFF Research Database (Denmark)

    Roberts, Nassim Bazeghi; Gerds, Thomas A; Budtz-Jørgensen, Esben

    2011-01-01

    Although there is widespread interest in fractional exhaled nitric oxide (FeNO) as a non-invasive, time and cost effective biomarker for assessing airway inflammation in chronic obstructive pulmonary disease (COPD), its usefulness is still controversial. We examined the FeNO levels in clinically...... (Caw). All patients had spirometry, assessment of symptoms with questionnaires and low-dose CT scan as well as assessment of weight and body composition. We examined the following subgroups of COPD: Patients with 1) Severe emphysema, 2) Chronic bronchitis, 3) Frequent exacerbations, 4) Loss of lean...

  11. Prospective early detection of avascular necrosis of the femoral head with MR imaging in high-risk patients: Is it clinically relevant

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Binswanger, U.

    1987-01-01

    To evaluate the clinical relevance of early detection of avascular necrosis (AVN) of the femoral head in a high-risk group, the authors performed MR imaging in 16 renal transplant patients receiving prednisone. Imaging was done at 3-month intervals over 8-24 months. Of the 15 patients remaining in the study (one underwent nephrectomy), two have shown clear MR imaging signs of early AVN persisting for 12 months without clinical symptoms. One patient had an abrupt onset of clinically relevant AVN before the second control MR imaging study was done. These results suggest that MR imaging may detect clinically irrelevant AVN, and that even short intervals between examinations may be too long to provide a warning of impending AVN

  12. Using language models to identify relevant new information in inpatient clinical notes.

    Science.gov (United States)

    Zhang, Rui; Pakhomov, Serguei V; Lee, Janet T; Melton, Genevieve B

    2014-01-01

    Redundant information in clinical notes within electronic health record (EHR) systems is ubiquitous and may negatively impact the use of these notes by clinicians, and, potentially, the efficiency of patient care delivery. Automated methods to identify redundant versus relevant new information may provide a valuable tool for clinicians to better synthesize patient information and navigate to clinically important details. In this study, we investigated the use of language models for identification of new information in inpatient notes, and evaluated our methods using expert-derived reference standards. The best method achieved precision of 0.743, recall of 0.832 and F1-measure of 0.784. The average proportion of redundant information was similar between inpatient and outpatient progress notes (76.6% (SD=17.3%) and 76.7% (SD=14.0%), respectively). Advanced practice providers tended to have higher rates of redundancy in their notes compared to physicians. Future investigation includes the addition of semantic components and visualization of new information.

  13. Existing reporting guidelines for clinical trials are not completely relevant for implantable medical devices: a systematic review.

    Science.gov (United States)

    Motte, Anne-France; Diallo, Stéphanie; van den Brink, Hélène; Châteauvieux, Constance; Serrano, Carole; Naud, Carole; Steelandt, Julie; Alsac, Jean-Marc; Aubry, Pierre; Cour, Florence; Pellerin, Olivier; Pineau, Judith; Prognon, Patrice; Borget, Isabelle; Bonan, Brigitte; Martelli, Nicolas

    2017-11-01

    The aim of this study was to determine relevant items for reporting clinical trials on implantable medical devices (IMDs) and to identify reporting guidelines which include these items. A panel of experts identified the most relevant items for evaluating IMDs from an initial list based on reference papers. We then conducted a systematic review of articles indexed in MEDLINE. We retrieved reporting guidelines from the EQUATOR network's library for health research reporting. Finally, we screened these reporting guidelines to find those using our set of reporting items. Seven relevant reporting items were selected that related to four topics: randomization, learning curve, surgical setting, and device information. A total of 348 reporting guidelines were identified, among which 26 met our inclusion criteria. However, none of the 26 reporting guidelines presented all seven items together. The most frequently reported item was timing of randomization (65%). On the contrary, device information and learning curve effects were poorly specified. To our knowledge, this study is the first to identify specific items related to IMDs in reporting guidelines for clinical trials. We have shown that no existing reporting guideline is totally suitable for these devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Serumferritin - diagnostic relevance and clinical usefulness

    Energy Technology Data Exchange (ETDEWEB)

    Linkesch, W [Vienna Univ. (Austria). 2. Medizinische Klinik

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value one should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e.g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia.

  15. Serumferritin - diagnostic relevance and clinical usefulness

    International Nuclear Information System (INIS)

    Linkesch, W.

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value on should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e. g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia. (Author)

  16. Improving dose homogeneity in head and neck radiotherapy with custom 3-D compensation

    International Nuclear Information System (INIS)

    Brock, Linda K.; Harari, Paul M.; Sharda, Navneet N.; Paliwal, Bhudatt R.; Kinsella, Timothy J.

    1996-01-01

    Purpose/Objective: Anatomic contour irregularities and tissue inhomogeneities can lead to significant radiation dose variation across complex treatment volumes. Such dose non-uniformity occurs routinely in radiation of the head and neck (H and N) despite beam shaping with blocks or beam modification with wedges. Small dose variations are amplified by the high total doses delivered (often >70 Gy) which can thereby influence late normal tissue complications as well as tumor control. We have therefore implemented the routine use of 3-D custom tissue compensators for our H and N cancer patients fabricated directly from CT scan contour data obtained in the treatment position. The capacity of such compensators to improve dose uniformity in patients with tumors of the H and N is herein reported. Materials and Methods: Between July 1992 and March 1995, 80 patients receiving H and N radiotherapy had 3-D custom compensators fabricated for their treatment course. Detailed dosimetric records have been reviewed for thirty cases to date (60 custom compensators). Dose uniformity across the treatment volume, peak dose delivery and maximum doses to selected, clinically relevant, anatomic subsites were analyzed and compared with uncompensated and wedged plans. Dose-volume histograms were generated and volumes receiving greater than 5% and 10% of the prescribed dose noted. Phantom dose measurements were performed for compensated fields using a water chamber and were compared to calculated doses in order to evaluate the accuracy of isodoses generated by the Theraplan treatment planning system. Accuracy of the fabrication and positioning of the custom compensators was verified by direct measurement. Results: Custom compensators resulted in an average reduction of dose variance across the treatment volume from 13.8% (7-20%) for the uncompensated plans to 4.5% (2-7%) with the compensators. Wedged plans were variable but on average an 8% (3-15%) dose variance was noted. Maximum doses

  17. Approaches for Establishing Clinically Relevant Dissolution Specifications for Immediate Release Solid Oral Dosage Forms.

    Science.gov (United States)

    Hermans, Andre; Abend, Andreas M; Kesisoglou, Filippos; Flanagan, Talia; Cohen, Michael J; Diaz, Dorys A; Mao, Y; Zhang, Limin; Webster, Gregory K; Lin, Yiqing; Hahn, David A; Coutant, Carrie A; Grady, Haiyan

    2017-11-01

    This manuscript represents the perspective of the Dissolution Analytical Working Group of the IQ Consortium. The intent of this manuscript is to highlight the challenges of, and to provide a recommendation on, the development of clinically relevant dissolution specifications (CRS) for immediate release (IR) solid oral dosage forms. A roadmap toward the development of CRS for IR products containing active ingredients with a non-narrow therapeutic window is discussed, within the context of mechanistic dissolution understanding, supported by in-human pharmacokinetic (PK) data. Two case studies present potential outcomes of following the CRS roadmap and setting dissolution specifications. These cases reveal some benefits and challenges of pursuing CRS with additional PK data, in light of current regulatory positions, including that of the US Food and Drug Administration (FDA), who generally favor this approach, but with the understanding that both industry and regulatory agency perspectives are still evolving in this relatively new field. The CRS roadmap discussed in this manuscript also describes a way to develop clinically relevant dissolution specifications based primarily on dissolution data for batches used in pivotal clinical studies, acknowledging that not all IR product development efforts need to be supported by additional PK studies, albeit with the associated risk of potentially unnecessarily tight manufacturing controls. Recommendations are provided on what stages during the life cycle investment into in vivo studies may be valuable. Finally, the opportunities for CRS within the context of post-approval changes, Modeling and Simulation (M&S), and the application of biowaivers, are briefly discussed.

  18. Registration of radiation doses

    International Nuclear Information System (INIS)

    2000-02-01

    In Finland the Radiation and Nuclear Safety Authority (STUK) is maintaining the register (called Dose Register) of the radiation exposure of occupationally exposed workers in order to ensure compliance with the principles of optimisation and individual protection. The guide contains a description of the Dose Register and specifies the responsibilities of the party running a radiation practice to report the relevant information to the Dose Register

  19. Dose-Volume Constraints to Reduce Rectal Side Effects From Prostate Radiotherapy: Evidence From MRC RT01 Trial ISRCTN 47772397

    International Nuclear Information System (INIS)

    Gulliford, Sarah L.; Foo, Kerwyn; Morgan, Rachel C.; Aird, Edwin G.; Bidmead, A. Margaret; Critchley, Helen; Evans, Philip M. D.Phil.; Gianolini, Stefano; Mayles, W. Philip; Moore, A. Rollo; Sanchez-Nieto, Beatriz; Partridge, Mike; Sydes, Matthew R. C.Stat; Webb, Steve; Dearnaley, David P.

    2010-01-01

    Purpose: Radical radiotherapy for prostate cancer is effective but dose limited because of the proximity of normal tissues. Comprehensive dose-volume analysis of the incidence of clinically relevant late rectal toxicities could indicate how the dose to the rectum should be constrained. Previous emphasis has been on constraining the mid-to-high dose range (≥50 Gy). Evidence is emerging that lower doses could also be important. Methods and Materials: Data from a large multicenter randomized trial were used to investigate the correlation between seven clinically relevant rectal toxicity endpoints (including patient- and clinician-reported outcomes) and an absolute 5% increase in the volume of rectum receiving the specified doses. The results were quantified using odds ratios. Rectal dose-volume constraints were applied retrospectively to investigate the association of constraints with the incidence of late rectal toxicity. Results: A statistically significant dose-volume response was observed for six of the seven endpoints for at least one of the dose levels tested in the range of 30-70 Gy. Statistically significant reductions in the incidence of these late rectal toxicities were observed for the group of patients whose treatment plans met specific proposed dose-volume constraints. The incidence of moderate/severe toxicity (any endpoint) decreased incrementally for patients whose treatment plans met increasing numbers of dose-volume constraints from the set of V30≤80%, V40≤65%, V50≤55%, V60≤40%, V65≤30%, V70≤15%, and V75≤3%. Conclusion: Considering the entire dose distribution to the rectum by applying dose-volume constraints such as those tested here in the present will reduce the incidence of late rectal toxicity.

  20. Clinically relevant diagnostic research in primary care: the example of B-type natriuretic peptides in the detection of heart failure.

    Science.gov (United States)

    Kelder, Johannes C; Rutten, Frans H; Hoes, Arno W

    2009-02-01

    With the emergence of novel diagnostic tests, e.g. point-of-care tests, clinically relevant empirical evidence is needed to assess whether such a test should be used in daily practice. With the example of the value of B-type natriuretic peptides (BNP) in the diagnostic assessment of suspected heart failure, we will discuss the major methodological issues crucial in diagnostic research; most notably the choice of the study population and the data analysis with a multivariable approach. BNP have been studied extensively in the emergency care setting, and also several studies in the primary care are available. The usefulness of this test when applied in combination with other readily available tests is still not adequately addressed in the relevant patient domain, i.e. those who are clinically suspected of heart failure by their GP. Future diagnostic research in primary care should be targeted much more at answering the clinically relevant question 'Is it useful to add this (new) test to the other tests I usually perform, including history taking and physical examination, in patients I suspect of having a certain disease'.

  1. Is dosing of therapeutic immunoglobulins optimal? – A review of a 3-decade long debate in Europe.

    Directory of Open Access Journals (Sweden)

    Jacqueline eKerr

    2014-12-01

    Full Text Available The consumption of immunoglobulins (Ig is increasing due to better recognition of antibody deficiencies, an aging population and new indications. This review aims to examine the various dosing regimens and research developments in the established and in some of the relevant off-label indications in Europe. The background to the current regulatory settings in Europe is provided as a backdrop for the latest developments in primary and secondary immunodeficiencies and in immunomodulatory indications. In these heterogeneous areas, clinical trials encompassing different routes of administration, varying intervals and infusion rates are paving the way towards more individualized therapy regimens.In primary antibody deficiencies adjustments in dosing and intervals will depend on the clinical presentation, effective IgG trough levels and IgG metabolism. Ideally, individual pharmacokinetic profiles in conjunction with the clinical phenotype could lead to highly tailored treatment. In practice, incremental dosage increases are necessary to titrate the optimal dose for more severely ill patients. Higher intravenous doses in these patients also have beneficial immunomodulatory effects beyond mere IgG replacement. Better understanding of the pharmacokinetics of Ig therapy is leading to a move away from simplistic ‘per kg’ dosing.Defective antibody production is common in many secondary immunodeficiencies irrespective of whether the causative factor was lymphoid malignancies (established indications, certain autoimmune disorders, immunosuppressive agents or biologics. This antibody failure, as shown by test immunisation, may be amenable to treatment with replacement Ig therapy. In certain immunomodulatory settings (e.g. ITP selection of patients for Ig therapy may be enhanced by relevant biomarkers in order to exclude non-responders and thus obtain higher response rates. In this review the developments in dosing of therapeutic immunoglobulins have been

  2. TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Dong, F. [The Cleveland Clinic (United States)

    2016-06-15

    Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise

  3. TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

    International Nuclear Information System (INIS)

    Dong, F.

    2016-01-01

    Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise

  4. Technical Note: The impact of deformable image registration methods on dose warping.

    Science.gov (United States)

    Qin, An; Liang, Jian; Han, Xiao; O'Connell, Nicolette; Yan, Di

    2018-03-01

    The purpose of this study was to investigate the clinical-relevant discrepancy between doses warped by pure image based deformable image registration (IM-DIR) and by biomechanical model based DIR (BM-DIR) on intensity-homogeneous organs. Ten patients (5Head&Neck, 5Prostate) were included. A research DIR tool (ADMRIE_v1.12) was utilized for IM-DIR. After IM-DIR, BM-DIR was carried out for organs (parotids, bladder, and rectum) which often encompass sharp dose gradient. Briefly, high-quality tetrahedron meshes were generated and deformable vector fields (DVF) from IM-DIR were interpolated to the surface nodes of the volume meshes as boundary condition. Then, a FEM solver (ABAQUS_v6.14) was used to simulate the displacement of internal nodes, which were then interpolated to image-voxel grids to get the more physically plausible DVF. Both geometrical and subsequent dose warping discrepancies were quantified between the two DIR methods. Target registration discrepancy(TRD) was evaluated to show the geometry difference. The re-calculated doses on second CT were warped to the pre-treatment CT via two DIR. Clinical-relevant dose parameters and γ passing rate were compared between two types of warped dose. The correlation was evaluated between parotid shrinkage and TRD/dose discrepancy. The parotid shrunk to 75.7% ± 9% of its pre-treatment volume and the percentage of volume with TRD>1.5 mm) was 6.5% ± 4.7%. The normalized mean-dose difference (NMDD) of IM-DIR and BM-DIR was -0.8% ± 1.5%, with range (-4.7% to 1.5%). 2 mm/2% passing rate was 99.0% ± 1.4%. A moderate correlation was found between parotid shrinkage and TRD and NMDD. The bladder had a NMDD of -9.9% ± 9.7%, with BM-DIR warped dose systematically higher. Only minor deviation was observed for rectum NMDD (0.5% ± 1.1%). Impact of DIR method on treatment dose warping is patient and organ-specific. Generally, intensity-homogeneous organs, which undergo larger deformation/shrinkage during

  5. First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose

    International Nuclear Information System (INIS)

    Boellaard, R.; Herk, M. van; Uiterwaal, H.; Mijnheer, B.

    1998-01-01

    Background and purpose: Recently, algorithms have been developed to derive the patient dose from portal dose measurements using a liquid-filled electronic portal imaging device. These algorithms have already been validated for several phantom geometries irradiated under clinical conditions. It is the aim of the present study to investigate the applicability of a liquid-filled electronic portal imaging device in combination with these algorithms for two-dimensional midplane dose verification in clinical practice. Measurements and methods: Portal dose images were obtained during several patient treatments under routine clinical conditions. Measurements were performed to verify the midplane dose during radiotherapy of larynx cancer with 4 MV beams, breast and lung cancer with 8 MV beams and prostate cancer with both 8 and 18 MV beams. Midplane doses, determined from portal dose measurements and analyzed with our algorithms, were compared with midplane doses calculated with our three-dimensional (3D) treatment planning system (TPS). Results: For the larynx treatment the measured 2D midplane dose agreed within 2.0% with TPS calculations in most parts of the field. Larger differences were found in a small region below the skin due to the absence of electron equilibrium, which is not taken into account in our portal dose analysis. For breast irradiations the measured midplane dose showed a homogeneous distribution in the AP direction in the axial plane, while high dose regions were observed in the cranial and caudal part of the breast. Portal dose measurements and TPS calculations agreed within 2.5% for most of the prostate and lung irradiations. For a few of the prostate and lung treatments larger local differences were found due to differences between the actual patient anatomy and the planning CT data, e.g. as a result of variable gas filling in the rectum and anatomical changes in the lung. Conclusions: Portal dose measurements with a liquid-filled electronic portal

  6. Biomarkers for Early Detection of Clinically Relevant Prostate Cancer. A Multi-Institutional Validation Trial

    Science.gov (United States)

    2016-10-01

    aim 2: Evaluate a panel of four-kallikrein plasma-based markers to determine the presence of or progression to clinically relevant prostate cancer...and sent to Genomic Health, Inc. for processing. Task 3: Analysis of scientific Aim 2: Evaluate a panel of four-kallikrein plasma-based markers to...site: FHCRC) PCA3 and the TMPRSS2:ERG fusion are prostate cancer-specific biomarkers that hold promise for stratifying risk in the setting of AS

  7. Time-driven activity-based costing in an outpatient clinic environment: development, relevance and managerial impact.

    Science.gov (United States)

    Demeere, Nathalie; Stouthuysen, Kristof; Roodhooft, Filip

    2009-10-01

    Healthcare managers are continuously urged to provide better patient services at a lower cost. To cope with these cost pressures, healthcare management needs to improve its understanding of the relevant cost drivers. Through a case study, we show how to perform a time-driven activity-based costing of five outpatient clinic's departments and provide evidence of the benefits of such an analysis.

  8. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, Heming; Nelms, Benjamin E.; Tome, Wolfgang A. [Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 and Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-10-15

    Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was

  9. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Lucas R., E-mail: lucas.rodrigues.borges@usp.br; Oliveira, Helder C. R. de; Nunes, Polyana F.; Vieira, Marcelo A. C. [Department of Electrical and Computer Engineering, São Carlos School of Engineering, University of São Paulo, 400 Trabalhador São-Carlense Avenue, São Carlos 13566-590 (Brazil); Bakic, Predrag R.; Maidment, Andrew D. A. [Department of Radiology, Hospital of the University of Pennsylvania, University of Pennsylvania, 3400 Spruce Street, Philadelphia, Pennsylvania 19104 (United States)

    2016-06-15

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe

  10. Method for simulating dose reduction in digital mammography using the Anscombe transformation.

    Science.gov (United States)

    Borges, Lucas R; Oliveira, Helder C R de; Nunes, Polyana F; Bakic, Predrag R; Maidment, Andrew D A; Vieira, Marcelo A C

    2016-06-01

    This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise

  11. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    International Nuclear Information System (INIS)

    Borges, Lucas R.; Oliveira, Helder C. R. de; Nunes, Polyana F.; Vieira, Marcelo A. C.; Bakic, Predrag R.; Maidment, Andrew D. A.

    2016-01-01

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe

  12. Clinically relevant pain relief with an ibuprofen-releasing foam dressing

    DEFF Research Database (Denmark)

    Fogh, Karsten; Andersen, Maibritt B; Bischoff-Mikkelsen, Morten

    2012-01-01

    The objective of this 6-week, 120-patient, double-blind, randomized, controlled trial was to investigate if a foam dressing with ibuprofen provided clinically relevant pain relief (PAR) for exuding, painful venous leg ulcers in comparison with a similar foam dressing without ibuprofen. Primary......) and the corresponding number needed to treat (NNT). Wound-related parameters such as ulcer healing, ulcer area reduction, and peri-ulcer skin condition as well as adverse events were recorded during all 6 weeks of the investigation. PAR was significantly greater in the ibuprofen foam group than the comparator group (p...... = 0.0438). There were 34% responders in the ibuprofen foam group vs. 19% in the comparator group (NNT = 6.8). When evening data were analyzed separately to evaluate PAR over daytime, NNT was 5.3. Wound healing parameters and adverse events were comparable. In conclusion, in this study, the ibuprofen...

  13. Clinical approaches involving thrombopoietin to shorten the period of thrombocytopenia after high-dose chemotherapy

    NARCIS (Netherlands)

    Tijssen, Marloes R.; van der Schoot, C. Ellen; Voermans, Carlijn; Zwaginga, Jaap Jan

    2006-01-01

    High-dose chemotherapy followed by a peripheral blood stem cell transplant is successfully used for a wide variety of malignancies. A major drawback, however, is the delay in platelet recovery. Several clinical strategies using thrombopoietin (Tpo) have been developed in an attempt to speed up

  14. Simulation of dose reduction in tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus

    2010-01-01

    Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose

  15. Clinical review: Optimal dose of continuous renal replacement therapy in acute kidney injury.

    Science.gov (United States)

    Prowle, John R; Schneider, Antoine; Bellomo, Rinaldo

    2011-01-01

    Continuous renal replacement therapy (CRRT) is the preferred treatment for acute kidney injury in intensive care units (ICUs) throughout much of the world. Despite the widespread use of CRRT, controversy and center-specific practice variation in the clinical application of CRRT continue. In particular, whereas two single-center studies have suggested survival benefit from delivery of higher-intensity CRRT to patients with acute kidney injury in the ICU, other studies have been inconsistent in their results. Now, however, two large multi-center randomized controlled trials - the Veterans Affairs/National Institutes of Health Acute Renal Failure Trial Network (ATN) study and the Randomized Evaluation of Normal versus Augmented Level (RENAL) Replacement Therapy Study - have provided level 1 evidence that effluent flow rates above 25 mL/kg per hour do not improve outcomes in patients in the ICU. In this review, we discuss the concept of dose of CRRT, its relationship with clinical outcomes, and what target optimal dose of CRRT should be pursued in light of the high-quality evidence now available.

  16. Effects of a higher dose of near-infrared light on clinical signs and neuroprotection in a monkey model of Parkinson's disease.

    Science.gov (United States)

    Moro, Cécile; El Massri, Nabil; Darlot, Fannie; Torres, Napoleon; Chabrol, Claude; Agay, Diane; Auboiroux, Vincent; Johnstone, Daniel M; Stone, Jonathan; Mitrofanis, John; Benabid, Alim-Louis

    2016-10-01

    We have reported previously that intracranial application of near-infrared light (NIr) - when delivered at the lower doses of 25J and 35J - reduces clinical signs and offers neuroprotection in a subacute MPTP (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) monkey model of Parkinson's disease. In this study, we explored whether a higher NIr dose (125J) generated beneficial effects in the same MPTP monkey model (n=15). We implanted an NIr (670nm) optical fibre device within a midline region of the midbrain in macaque monkeys, close to the substantia nigra of both sides. MPTP injections (1.8-2.1mg/kg) were made over a five day period, during which time the NIr device was turned on and left on continuously throughout the ensuing three week survival period. Monkeys were evaluated clinically and their brains processed for immunohistochemistry and stereology. Our results showed that the higher NIr dose did not have any toxic impact on cells at the midbrain implant site. Further, this NIr dose resulted in a higher number of nigral tyrosine hydroxylase immunoreactive cells when compared to the MPTP group. However, the higher NIr dose monkeys showed little evidence for an increase in mean clinical score, number of nigral Nissl-stained cells and density of striatal tyrosine hydroxylase terminations. In summary, the higher NIr dose of 125J was not as beneficial to MPTP-treated monkeys as compared to the lower doses of 25J and 35J, boding well for strategies of NIr dose delivery and device energy consumption in a future clinical trial. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Lateral rectal shielding reduces late rectal morbidity after high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a dose effect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W Robert; Hanks, Gerald E; Hanlon, Alexandra; Schultheiss, Timothy E

    1995-07-01

    Purpose: Using conventional treatment methods for the treatment of clinically localized prostate cancer central axis doses must be limited to 65-70 Gy to prevent significant damage to nearby normal tissues. A fundamental hypothesis of three-dimensional conformal radiation therapy (3DCRT) is that, by defining the target organ(s) accurately in three dimensions, it is possible to deliver higher doses to the target without a significant increase in normal tissue complications. This study examines whether this hypothesis holds true and whether a simple modification of treatment technique can reduce the incidence of late rectal morbidity in patients with prostate cancer treated with 3DCRT to minimum planning target volume (PTV) doses of 71-75 Gy. Materials and Methods: 257 patients with clinically localized prostate cancer completed 3DCRT by December 31, 1993 and received a minimum PTV dose of 71-75 Gy. The median follow-up time was 22 months (range 4-67 months) and 98% of patients had followup of longer than 12 months. The calculated dose at the center of the prostate was <74 Gy in 19 patients, 74-76 Gy in 206 patients and >76 Gy in 32 patients. Late rectal morbidity was graded according to the LENT scoring system. Eighty-eight consecutive patients were treated with a rectal block added to the lateral fields. In these patients the posterior margin from the prostate to the block edge was reduced from the standard 15 mm to 7.5 mm for the final 10 Gy which reduced the dose to portions of the anterior rectal wall by approximately 4-5 Gy. Estimates of rates for rectal morbidity were determined by Kaplan-Meier actuarial analyses. Differences in morbidity percentages were evaluated by the Pearson chi square test. Results: Grade 2-3 rectal morbidity developed in 46 of 257 patients (18%) and in the majority of cases consisted of rectal bleeding. No patient has developed grade 4 or 5 rectal morbidity. The actuarial rate of grade 2-3 morbidity is 22% at 24 months and the median

  18. HALF-DOSE DEPOT TRIPTORELIN COMPARABLE TO REDUCED DAILY BUSERELIN: A RANDOMIZED CLINICAL TRIAL

    Directory of Open Access Journals (Sweden)

    L. Safdarian

    2007-09-01

    Full Text Available Pituitary suppression by depot GnRH agonist may be excessive for ovarian stimulation. This study compares the efficacy of a single half-dose depot triptorelin and reduced-dose daily buserelin in a long protocol ICSI/ET. METHODS: A total of 182 patients were randomized into two groups using sealed envelopes. Pituitary desensitization was obtained in group 1 (91 patients with half-dose (1.87 mg depot triptorelin in the mid-luteal phase of their menstrual cycle, and in group 2 (91 patients with standard daily dose (0.5 mg buserelin, which was then reduced to 0.25 mg at the start of human menopausal gonadotropin (HMG stimulation. RESULTS: No significant differences were found among those who received HCG in terms of clinical pregnancy rate (34.4% in both groups, implantation rate (14.8% in group 1 versus 11.1% in group 2, fertilization rate (93.3 versus 95.6%, poor response rate (11.1 versus 6.7%, and miscarriage rate (11.1 versus 7.8%. No significant differences were seen in number of HMG ampoules used, follicles at HCG administration, and oocytes retrieved. The number of days of stimulation was significantly reduced in group 2 (11.2 +/- 1.8 in group 1 versus 10.6 +/- 1.9, p = 0.030. CONCLUSION: A half-dose of depot triptorelin can be successfully used in ovarian stimulation instead of reduced-dose daily buserelin, with more patient comfort and reduced stress and cost of injections.

  19. Promoting culturally competent chronic pain management using the clinically relevant continuum model.

    Science.gov (United States)

    Monsivais, Diane B

    2011-06-01

    This article reviews the culture of biomedicine and current practices in pain management education, which often merge to create a hostile environment for effective chronic pain care. Areas of cultural tensions in chronic pain frequently involve the struggle to achieve credibility regarding one's complaints of pain (or being believed that the pain is real) and complying with pain medication protocols. The clinically relevant continuum model is presented as a framework allowing providers to approach care from an evidence-based, culturally appropriate (patient centered) perspective that takes into account the highest level of evidence available, provider expertise, and patient preferences and values. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. CLINICAL AND PHARMACOLOGICAL APPROACHES TO OPTIMIZE THE DOSING REGIMEN OF ANTIBACTERIAL DRUGS IN PEDIATRICS

    Directory of Open Access Journals (Sweden)

    Natal’ya B. Lazareva

    2018-01-01

    Full Text Available The rational use of antibacterial drugs in children implies an adequate choice of the necessary medication, its dosing regimen, and the duration of treatment in order to achieve maximum efficacy and minimize toxic effects. The knowledge of pharmacokinetic and pharmacodynamic profiles of the antibacterial drug plays a crucial role for optimizing the dosing regimen. The strategy of individual choice of the dosing regimen, taking into account the principles of pharmacokinetics and pharmacodynamics, can be especially effective in patients with the expectedly changed parameters of pharmacokinetics and in infections caused by bacteria strains with low sensitivity to antibiotics. The review presents a contemporary view of pharmacokinetic and pharmacodynamic profiles of antibacterial drugs most commonly used in pediatrics and their relationship to the clinical efficacy of the administered therapy.

  1. Continual reassessment method for dose escalation clinical trials in oncology: a comparison of prior skeleton approaches using AZD3514 data.

    Science.gov (United States)

    James, Gareth D; Symeonides, Stefan N; Marshall, Jayne; Young, Julia; Clack, Glen

    2016-08-31

    The continual reassessment method (CRM) requires an underlying model of the dose-toxicity relationship ("prior skeleton") and there is limited guidance of what this should be when little is known about this association. In this manuscript the impact of applying the CRM with different prior skeleton approaches and the 3 + 3 method are compared in terms of ability to determine the true maximum tolerated dose (MTD) and number of patients allocated to sub-optimal and toxic doses. Post-hoc dose-escalation analyses on real-life clinical trial data on an early oncology compound (AZD3514), using the 3 + 3 method and CRM using six different prior skeleton approaches. All methods correctly identified the true MTD. The 3 + 3 method allocated six patients to both sub-optimal and toxic doses. All CRM approaches allocated four patients to sub-optimal doses. No patients were allocated to toxic doses from sigmoidal, two from conservative and five from other approaches. Prior skeletons for the CRM for phase 1 clinical trials are proposed in this manuscript and applied to a real clinical trial dataset. Highly accurate initial skeleton estimates may not be essential to determine the true MTD, and, as expected, all CRM methods out-performed the 3 + 3 method. There were differences in performance between skeletons. The choice of skeleton should depend on whether minimizing the number of patients allocated to suboptimal or toxic doses is more important. NCT01162395 , Trial date of first registration: July 13, 2010.

  2. What's New in the Medicine Cabinet?: A Panoramic Review of Clinically Relevant Information for the Busy Dermatologist.

    Science.gov (United States)

    Del Rosso, James Q; Zeichner, Joshua

    2014-01-01

    This article is the first in a periodic series of therapeutic topics with short reviews gleaned from major dermatology meetings, especially Scientific Poster Sessions, and is designed to provide information that may assist the readers in adapting information from the literature to their clinical practice. The topics covered in this issue are discussions of the clinical relevance of newer information about acne pathophysiology, acne in adult women, and topical corticosteroid spray formulations for chronic plaque psoriasis.

  3. Clinical Factors Associated with Dose of Loop Diuretics After Pediatric Cardiac Surgery: Post Hoc Analysis.

    Science.gov (United States)

    Haiberger, Roberta; Favia, Isabella; Romagnoli, Stefano; Cogo, Paola; Ricci, Zaccaria

    2016-06-01

    A post hoc analysis of a randomized controlled trial comparing the clinical effects of furosemide and ethacrynic acid was conducted. Infants undergoing cardiac surgery with cardiopulmonary bypass were included in order to explore which clinical factors are associated with diuretic dose in infants with congenital heart disease. Overall, 67 patients with median (interquartile range) age of 48 (13-139) days were enrolled. Median diuretic dose was 0.34 (0.25-0.4) mg/kg/h at the end of postoperative day (POD) 0 and it significantly decreased (p = 0.04) over the following PODs; during this period, the ratio between urine output and diuretic dose increased significantly (p = 0.04). Age (r -0.26, p = 0.02), weight (r -0.28, p = 0.01), cross-clamp time (r 0.27, p = 0.03), administration of ethacrynic acid (OR 0.01, p = 0.03), and, at the end of POD0, creatinine levels (r 0.3, p = 0.009), renal near-infrared spectroscopy saturation (-0.44, p = 0.008), whole-blood neutrophil gelatinase-associated lipocalin levels (r 0.30, p = 0.01), pH (r -0.26, p = 0.02), urinary volume (r -0.2755, p = 0.03), and fluid balance (r 0.2577, p = 0.0266) showed a significant association with diuretic dose. At multivariable logistic regression cross-clamp time (OR 1.007, p = 0.04), use of ethacrynic acid (OR 0.2, p = 0.01) and blood pH at the end of POD0 (OR 0.0001, p = 0.03) was independently associated with diuretic dose. Early resistance to loop diuretics continuous infusion is evident in post-cardiac surgery infants: Higher doses are administered to patients with lower urinary output. Independently associated variables with diuretic dose in our population appeared to be cross-clamping time, the administration of ethacrynic acid, and blood pH.

  4. Population pharmacokinetics of exendin-(9-39) and clinical dose selection in patients with congenital hyperinsulinism.

    Science.gov (United States)

    Ng, Chee M; Tang, Fei; Seeholzer, Steven H; Zou, Yixuan; De León, Diva D

    2018-03-01

    Congenital hyperinsulinism (HI) is the most common cause of persistent hypoglycaemia in infants and children. Exendin-(9-39), an inverse glucagon-like peptide 1 (GLP-1) agonist, is a novel therapeutic agent for HI that has demonstrated glucose-raising effect. We report the first population pharmacokinetic (PopPK) model of the exendin-(9-39) in patients with HI and propose the optimal dosing regimen for future clinical trials in neonates with HI. A total of 182 pharmacokinetic (PK) observations from 26 subjects in three clinical studies were included for constructing the PopPK model using first order conditional estimation (FOCE) with interaction method in nonlinear mixed-effects modelling (NONMEM). Exposure metrics (area under the curve [AUC] and maximum plasma concentration [C max ]) at no observed adverse effect levels (NOAELs) in rats and dogs were determined in toxicology studies. Observed concentration-time profiles of exendin-(9-39) were described by a linear two-compartmental PK model. Following allometric scaling of PK parameters, age and creatinine clearance did not significantly affect clearance. The calculated clearance and elimination half-life for adult subjects with median weight of 69 kg were 11.8 l h -1 and 1.81 h, respectively. The maximum recommended starting dose determined from modelling and simulation based on the AUC 0-last at the NOAEL and predicted AUC 0-inf using the PopPK model was 27 mg kg -1  day -1 intravenously. This is the first study to investigate the PopPK of exendin-(9-39) in humans. The final PopPK model was successfully used with preclinical toxicology findings to propose the optimal dosing regimen of exendin-(9-39) for clinical studies in neonates with HI, allowing for a more targeted dosing approach to achieve desired glycaemic response. © 2017 The British Pharmacological Society.

  5. The clinical demand for information and the radiation dose in pelvimetry and amniography

    International Nuclear Information System (INIS)

    Wilbrand, H.F.; Lindmark, G.; Ytterbergh, C.

    1982-01-01

    Radiographic measurements are an important part of antenatal care and are in fact used to a great extent in nulliparous women. In view of this clinical background and also for ethical reasons, reduction of the radiation doses is mandatory. As radiographic pelvimetry is used in so many pregnant women, it is of importance that no higher radiation doses are applied than are absolutely needed to guarantee correct and necessary information. Dose reduction is afforded in two different ways - by optimizing the imaging techniques and by closing a suitable film-screen combination. Measurement of absorbed doses in patients was carried out with highly sensitive lithium fluoride thermoluminiscence dosimeters (TLD) with a dimension of 3x3x0.9 mm (Harshaw type TLD-100). All TLD probes were calibrated with Co60 radiation between the measurement series. Absorbed radiation doses were measured in the rectum for different film-screen combinations. Depending on the position of the fetus in relation to the maternal pelvis, it is obvious that in any individual case varying parts of the fetus will lie directly in the radiation beam. In amniography the absorbed radiation doses will vary from case to case depending on the number of exposures, which should not exceed six, and the duration of fluoroscopy, which should be no longer than 1 min. With the use of lanex Regular screens and highly coned images the radiation dose will not exceed 3.0 mGy. Since a high image quality is mandatory for evaluation of disorders in the fetal skeleton, measurements were not performed with other high-speed screens. The MR 800 screen appears to provide further reduction of the radiation dose in this type of examination. (orig./MG)

  6. Nicotine at clinically relevant concentrations affects atrial inward rectifier potassium current sensitive to acetylcholine.

    Science.gov (United States)

    Bébarová, Markéta; Matejovič, Peter; Švecová, Olga; Kula, Roman; Šimurdová, Milena; Šimurda, Jiří

    2017-05-01

    Nicotine abuse is associated with variety of diseases including arrhythmias, most often atrial fibrillation (AF). Altered inward rectifier potassium currents including acetylcholine-sensitive current I K(Ach) are known to be related to AF pathogenesis. Since relevant data are missing, we aimed to investigate I K(Ach) changes at clinically relevant concentrations of nicotine. Experiments were performed by the whole cell patch clamp technique at 23 ± 1 °C on isolated rat atrial myocytes. Nicotine was applied at following concentrations: 4, 40 and 400 nM; ethanol at 20 mM (∼0.09%). Nicotine at 40 and 400 nM significantly activated constitutively active component of I K(Ach) with the maximum effect at 40 nM (an increase by ∼100%); similar effect was observed at -110 and -50 mV. Changes at 4 nM nicotine were negligible on average. Coapplication of 40 nM nicotine and 20 mM ethanol (which is also known to activate this current) did not show cumulative effect. In the case of acetylcholine-induced component of I K(Ach) , a dual effect of nicotine and its correlation with the current magnitude in control were apparent: the current was increased by nicotine in the cells showing small current in control and vice versa. The effect of 40 and 400 nM nicotine on acetylcholine-induced component of I K(Ach) was significantly different at -110 and -50 mV. We conclude that nicotine at clinically relevant concentrations significantly increased constitutively active component of I K(Ach) and showed a dual effect on its acetylcholine-induced component, similarly as ethanol. Synchronous application of nicotine and ethanol did not cause additive effect.

  7. Phase I (or phase II) dose-ranging clinical trials: proposal of a two-stage Bayesian design.

    Science.gov (United States)

    Zohar, Sarah; Chevret, Sylvie

    2003-02-01

    We propose a new design for phase I (or phase II) dose-ranging clinical trials aiming at determining a dose of an experimental treatment to satisfy safety (respectively efficacy) requirements, at treating a sufficiently large number of patients to estimate the toxicity (respectively failure) probability of the dose level with a given reliability, and at stopping the trial early if it is likely that no dose is safe (respectively efficacious). A two-stage design was derived from the Continual Reassessment Method (CRM), with implementation of Bayesian criteria to generate stopping rules. A simulation study was conducted to compare the operating characteristics of the proposed two-stage design to those reached by the traditional CRM. Finally, two applications to real data sets are provided.

  8. Selective fallopian tube catheterisation in female infertility: clinical results and absorbed radiation dose

    International Nuclear Information System (INIS)

    Nakamura, K.; Ishiguchi, T.; Maekoshi, H.; Ando, Y.; Tsuzaka, M.; Tamiya, T.; Suganuma, N.; Ishigaki, T.

    1996-01-01

    Clinical results of fluoroscopic fallopian tube catheterisation and absorbed radiation doses during the procedure were evaluated in 30 infertility patients with unilateral or bilateral tubal obstruction documented on hysterosalpingography. The staged technique consisted of contrast injection through an intrauterine catheter with a vacuum cup device, ostial salpingography with the wedged catheter, and selective salpingography with a coaxial microcatheter. Of 45 fallopian tubes examined, 35 (78 %) were demonstrated by the procedure, and at least one tube was newly demonstrated in 26 patients (87 %). Six of these patients conceived spontaneously in the follow-up period of 1-11 months. Four pregnancies were intrauterine and 2 were ectopic. This technique provided accurate and detailed information in the diagnosis and treatment of tubal obstruction in infertility patients. The absorbed radiation dose to the ovary in the average standardised procedure was estimated to be 0.9 cGy. Further improvement in the X-ray equipment and technique is required to reduce the radiation dose. (orig.). With 3 figs., 3 tabs

  9. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  10. Clinical characteristic of epidemic hepatitis in case of the effect of low dose irradiation

    International Nuclear Information System (INIS)

    Geras'kov, O.P.; Shubik, V.M.

    1990-01-01

    Clinical course of infections hepatitics B, developed on the background of pulmonary tuberculosis in people, who were subjected to chronic low dose ionizing radiation, indicated more frequent cases of severe and medium-severe forms of morbidity as compared to non-irradiated patients and those with no comitant pulmonary tuberculosis. However the reconvalescence terms, hepatitis size normalization, urine colour in different group patients did not differ essentially. The data obtained testify to the absence of significant peculiarities in the course of infections hepatitis B, combined with pulmonar tuberculosis under conditions of chronic low dose ionizing radiation. 3 refs.; 3 tabs

  11. SU-E-T-256: Radiation Dose Responses for Chemoradiation Therapy of Pancreatic Cancer: An Analysis of Compiled Clinical Data Using Biophysical Models.

    Science.gov (United States)

    Moraru, I; Tai, A; Erickson, B; Li, X

    2012-06-01

    We have analyzed recent clinical data obtained from chemoradiation of unresectable, locally advanced pancreatic cancer in order to examine possible benefits from radiotherapy (RT) dose escalation as well as to propose possible dose escalated fractionation schemes. A modified linear quadratic (LQ) model was used to fit clinical tumor response data from chemoradiation treatments using different fractionations. Biophysical radiosensitivy parameters, a and α/β, tumor potential doubling time, Td, and delay time for tumor doubling during treatment, Tk, were extracted from the fits and were used to calculate feasible fractionation schemes for dose escalations. Examination of published data from 20 institutions showed no clear indication of improved survival with raised radiation dose. However, an enhancement in tumor response was observed for higher irradiation doses, an important and promising clinical Result with respect to palliation and quality of life. The radiobiological parameter estimates obtained from the analysis are: α/β = 10 ± 3 Gy, a = 0.010 ± 0.003 Gŷ-1, Td = 56 ± 5 days and Tk = 7 ± 2 days. Possible dose escalation schemes are proposed based on the calculation of the biologically equivalent dose (BED) required for a 50% tumor response rate. From the point of view of tumor response, escalation of the administered radiation dose leads to a potential clinical benefit, which when combined with normal tissue complication analyses may Result in improved treatments for certain patients with advanced pancreatic cancer. Based on this analysis, a dose escalation trial with 2.25 Gy/fraction up to 69.75 Gy is being initiated for unresectable pancreatic cancer at our institution. Partially supported by MCW Cancer Center Meinerz Foundation. © 2012 American Association of Physicists in Medicine.

  12. Proposal of dose constraint values to the patient in diagnostic radiology

    International Nuclear Information System (INIS)

    Arranz, L.; Sastre, J.M.; Ferrer, N.; Andres, J.C. De; Guibelalde, E.; Tobarra, B.; Madrid, G.

    1996-01-01

    A dose constraint is the value of an individual dose not to be exceeded in the individual dose distribution considered in an optimization process. The objective of a dose constraints is to set a ceiling to the doses to individual from a source, practice or task which are considered acceptable in the optimization process at the design stage. Implicitly, as C. Zuur states, dose constraints are below the relevant dose limit and usually should be established as local or national levels. Exposures for medical purposes are not subject to dose limits and hence dose constraints were recommended by the ICRP just for occupational and public exposures. However, as an effective tool for optimization for medical exposures, ICRP-60 in paragraph 180 recognizes the value of applying this concept to patient diagnostic radiology with some peculiarities: 'Considerations should be given to the use of dose constraints, or investigation levels, selected by the appropriate professional or regulatory agency, for application in some common diagnostic procedures. They should be applied with flexibility to allow higher cases where indicated by sound clinical judgement.' This paper analyzes retrospectively the dose levels imparted to patient in some common examinations (chest, lumbar spine and mammography) at different optimization stages of different facilities to propose some local constraints for diagnostic examinations. Dose values have been obtained under routine working conditions. Centres included in the survey have been chosen all over Spain, classifying them with particular attention to the following aspects: -Organizational aspects of the diagnostic radiology service, i.e., operational, technical and clinical criteria, as well as quality requirements. - Evaluation and revision of routine medical protocols. -Quality control of the radiological equipment. - Quality criteria for the surveillance of the weekly procedures, with requirements of proper training of die technical staff

  13. Clinical relevance and scope of accidental extracoronary findings in coronary computed tomography angiography: A cardiac versus thoracic FOV study

    Energy Technology Data Exchange (ETDEWEB)

    Aglan, Iman; Jodocy, Daniel; Hiehs, Stefan; Soegner, Peter; Frank, Renate; Haberfellner, Berhard; Klauser, Andrea; Jaschke, Werner [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria); Feuchtner, Gudrun M. [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria)], E-mail: Gudrun.Feuchtner@i-med.ac.at

    2010-04-15

    Objective: To assess the spectrum and clinical relevance of extracoronary findings in coronary CT angiography (CCTA), and to compare a small (cardiac) field of view (FOV) to a large (thoracic) FOV setting. Material and methods: 1084 consecutive patients (mean 57 years) with low-to-intermediate risk of coronary artery disease were enrolled. 542 CCTA scans were interpreted with small FOV (160-190 mm{sup 2}) encompassing the cardiac region. In another 542 CCTA (patients matched for age and gender), read-out of an additional full FOV (>320 mm{sup 2}) covering the thorax was performed. Clinical relevance of extracoronary findings was considered as either 'significant' or 'non-significant'. 'Significant' findings were subclassified as either score 1: findings necessitating immediate therapeutic actions, or score 2: findings with undoubted clinical or prognostic relevance, requiring clinical awareness, follow-up or further investigations (non-urgent). 'Non-significant' findings were assigned to either score 3: findings not requiring follow-up or further tests, or as score 4: irrelevant incidental findings. Results: Significantly more patients with extracoronary findings were identified by using a full FOV with 43.2% (234/542) compared to a small FOV with 33.6% (182/542) (p = 0.001). Similarly, a higher total number of extracoronary findings (n = 394) was found on full FOV compared to small FOV (n = 250) (p < 0.001). The detection rate of clinically significant findings was higher by using full FOV compared to small FOV (25.6% versus 15.4%) (p < 0.001), out of those 2.2% versus 1.8% of findings required immediate actions (score 1), and 23.4% versus 13.6% (p = 0.0001), respectively were of clinical relevance (non-urgent, score 2). The rate of malign findings was 0.2%, and of acute pulmonary embolism 0.1%. More lung pathologies were observed by using full FOV compared to small FOV (22% versus 7%) (p < 0.0001), and the detection rate of

  14. Elimination of ascorbic acid after high-dose infusion in prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben Kjær; Højgaard, Martin; Andersen, Jon Thor Trærup

    2015-01-01

    IV AA. The purpose of the present study was to assess the basic kinetic variables in human beings over a relevant AA dosing interval for proper design of future clinical trials. Ten patients with metastatic prostate cancer were treated for four weeks with fixed AA doses of 5, 30 and 60 g. AA...... was measured consecutively in plasma and indicated first-order elimination kinetics throughout the dosing range with supra-physiological concentrations. The target dose of 60g AA IV produced a peak plasma AA concentration of 20.3 mM. Elimination half-life was 1.87 hr (mean, SD ± 0.40), volume of distribution 0.......19 L/kg (SD ±0.05) and clearance rate 6.02 L/hr (100mL/min). No differences in pharmacokinetic parameters were observed between weeks/doses. A relatively fast first-order elimination with half-life of about 2 hr makes it impossible to maintain AA concentrations in the potential cytotoxic range after...

  15. Evaluation of a fixed-dose combination of benazepril and pimobendan in dogs with congestive heart failure: a randomized non-inferiority clinical trial.

    Science.gov (United States)

    King, Jonathan N; Hirakawa, Atsushi; Sonobe, Junko; Otaki, Hiroshi; Sakakibara, Nobuhiro; Seewald, Wolfgang; Forster, Sophie

    2018-01-31

    A fixed-dose combination tablet of benazepril and pimobendan (Fortekor Plus; Elanco Animal Health) was tested in dogs with congestive heart failure (CHF) caused by myxomatous mitral valve disease (MMVD) in a three-arm, masked, randomized, non-inferiority clinical trial in Japan. The test group (n = 34) received Fortekor Plus twice daily. Two control groups received registered formulations of benazepril (Fortekor; Elanco Animal Health) and pimobendan (Vetmedin; Boehringer Ingelheim Vetmedica) with administration of Vetmedin twice daily and Fortekor twice (Control I, n = 14) or once (Control II, n = 19) daily. Diuretics were used in 22 dogs (32.8%). Global clinical scores decreased significantly from baseline in all groups; there were no significant differences between groups, and non-inferiority of Fortekor Plus compared to Control I, Control II, and combined Control I + II groups was demonstrated. There were no significant differences between groups for relevant clinical chemistry and hematology variables or frequency of all adverse events. Frequency of emesis was significantly ( p = 0.0042) lower in the Fortekor Plus (8.8%) group than in the Control I + II (39.4%) group. In conclusion, Fortekor Plus had non-inferior efficacy and was associated with significantly less emesis compared to Fortekor and Vetmedin in dogs with CHF caused by MMVD.

  16. A Phase I clinical trial of lodenafil carbonate, a new phosphodiesterase Type 5 (PDE5) inhibitor, in healthy male volunteers.

    Science.gov (United States)

    Mendes, Gustavo D; dos Santos Filho, Hilton Oliveira; dos Santos Pereira, Alberto; Mendes, Fabiana D; Ilha, Jaime O; Alkharfy, Khalid M; De Nucci, Gilberto

    2012-12-01

    Lodenafil carbonate is a new phosphodiesterase Type 5 (PDE5) inhibitor used in treatment of erectile dysfunction. The present study was conducted to evaluate the safety, tolerability, and pharmacokinetics of lodenafil carbonate after administering ascending (1 - 100 mg) single oral doses to healthy male volunteers (n = 33). The study was an open label, dose-escalation, Phase I clinical trial involving the administration of single oral doses of lodenafil carbonate. Lodenafil carbonate was administered sequentially, escalating in single doses of 1 mg - 100 mg with a washout period of at least 1 week between each dose. The progression to the next dose was allowed after clinical and laboratory exams, Ambulatory Monitoring of Arterial Pressure (AMAP) without relevant clinical modifications and adverse events without clinical relevancy. Blood samples were collected at pre-dose, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 4.5, 5, 6, 7, 8, 10, 12, 14, 16, 20 and 24 h post-dosing. Plasma samples for measurement of lodenafil carbonate and lodenafil were analyzed by liquid chromatography coupled to tandem mass spectrometry. No serious adverse events were observed, and none of the subjects discontinued the study due to intolerance. The AMAP measurements, clinical and laboratory exams and ECG revealed no significant changes even at higher doses. Lodenafil carbonate was not detected in any samples, indicating that it acts as a prodrug. The mean lodenafil pharmacokinetic parameters for tmax and t1/2 were 1.6 ( ± 0.4) h and 3.3 ( ± 1.1) h, respectively. This study demonstrated that lodenafil carbonate was well tolerated and showed a good safety profile in healthy male volunteers.

  17. Macrotrabecular-massive hepatocellular carcinoma: A distinctive histological subtype with clinical relevance.

    Science.gov (United States)

    Ziol, Marianne; Poté, Nicolas; Amaddeo, Giuliana; Laurent, Alexis; Nault, Jean-Charles; Oberti, Frédéric; Costentin, Charlotte; Michalak, Sophie; Bouattour, Mohamed; Francoz, Claire; Pageaux, Georges Philippe; Ramos, Jeanne; Decaens, Thomas; Luciani, Alain; Guiu, Boris; Vilgrain, Valérie; Aubé, Christophe; Derman, Jonathan; Charpy, Cécile; Zucman-Rossi, Jessica; Barget, Nathalie; Seror, Olivier; Ganne-Carrié, Nathalie; Paradis, Valérie; Calderaro, Julien

    2017-12-27

    We recently identified a novel histological subtype of hepatocellular carcinoma, designated as "macrotrabecular-massive" (MTM-HCC) and associated with specific molecular features. In order to assess the clinical relevance of this novel variant, we aimed to investigate its prognostic value in two large series of patients with HCC treated either by surgical resection or radiofrequency ablation (RFA). We retrospectively included 237 HCC surgical samples and 284 HCC liver biopsies from patients treated by surgical resection and RFA, respectively. Histological slides were reviewed by pathologists specialized in liver disease, and the MTM-HCC subtype was defined by the presence of a predominant (>50%) macrotrabecular architecture (more than 6 cells thick). The main clinical and biological features were recorded at baseline. Clinical endpoints were early and overall recurrence. The MTM-HCC subtype was identified in 12% of the whole cohort (16% of surgically resected samples, 8.5% of liver biopsy samples). It was associated at baseline with known poor prognostic factors (tumor size, AFP level, satellite nodules and vascular invasion). Multivariate analysis showed that MTM-HCC subtype was an independent predictor of early and overall recurrence (surgical series: OR 3.03 (1.38-6.65), p=0.006 and 2.76 (1.63-4.67), pvalue was retained even after patients stratification according to common clinical, biological and pathological features of aggressiveness. No other baseline parameter was independently associated to recurrence in the RFA series. The MTM-HCC subtype, reliably observed in 12% of patients eligible for a curative treatment, represents an aggressive form of HCC that may require more specific therapeutic strategies. This article is protected by copyright. All rights reserved. © 2017 by the American Association for the Study of Liver Diseases.

  18. Education in the clinical context: establishing a strategic framework to ensure relevance.

    Science.gov (United States)

    Henderson, Amanda; Fox, Robyn; Armit, Lyn

    2008-01-01

    Quality contemporary practice relies on nurses to provide health care within an embedded nexus of clinical, professional and organisational learning that leads them through a career trajectory that encourages lifelong development. Within complex health service environments this is fraught with difficulties. Enhancing practice is multifaceted requiring not just education for the acquisition of skills and abilities but time and space for reflection on experience within the clinical context. This ultimately leads to professional knowledge development. Queensland Health has developed a Nursing and Midwifery Staff Development Framework to assist nurses in structuring their experiences in the practice setting to enable their professional goals. Learning is guided within this framework through its collective modus operandi, that is, the development of teams that overlap to identify and progress the educational agenda; resources to develop consistent relevant learning material that incorporates evidence obtained through practices and the literature; and educator and clinician networks across health services throughout the state, and furthermore, links with the tertiary sector to assist in marketing, applicability and synergy with further education.

  19. The potential use of ultra-low radiation dose images in digital mammography-a clinical proof-of-concept study in craniocaudal views

    NARCIS (Netherlands)

    Bluekens, A. M. J.; Veldkamp, W. J. H.; Schuur, K. H.; Karssemeijer, N.; Broeders, M. J. M.; den Heeten, G. J.

    2015-01-01

    Objective: To estimate the potential of low-dose images in digital mammography by analysing the effect of substantial dose reduction in craniocaudal (CC) views on clinical performance. Methods: At routine mammography, additional CC views were obtained with about 10% of the standard dose. Five

  20. The potential use of ultra-low radiation dose images in digital mammography--a clinical proof-of-concept study in craniocaudal views

    NARCIS (Netherlands)

    Bluekens, A.M.; Veldkamp, W.J.H.; Schuur, K.H.; Karssemeijer, N.; Broeders, M.J.; Heeten, GJ. den

    2015-01-01

    OBJECTIVE: To estimate the potential of low-dose images in digital mammography by analysing the effect of substantial dose reduction in craniocaudal (CC) views on clinical performance. METHODS: At routine mammography, additional CC views were obtained with about 10% of the standard dose. Five

  1. Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures

    Science.gov (United States)

    Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O

    2012-01-01

    Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404

  2. Creation and clinical application of real-time dose monitor using dose area product meter

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Uoyama, Yoshinori; Iida, Hiroji; Mizushima, Takashi

    2004-01-01

    The management of patient dose has become more of an issue in recent years. Dose can be determined non-invasively and in real time through the use of a dose area product meter, but it is the area dose value that is obtained. Therefore, we created a program that estimates entrance skin dose (ESD) in real time from area dose values obtained during procedures. We used Microsoft Visual C++ 6.0 (Standard Edition) for the programming language and C language for the programming environment. The value was a maximum 285.4 mGy at ileus tube insertion when measuring ESD for radiography of the digestive organ and non-vascular type interventional radiology (IVR) using the created program and seeking the average according to the procedures. The program that we created can be considered valid for monitoring ESD correctly and in real time. (author)

  3. Toxicity of TiO2 nanoparticles on soil nitrification at environmentally relevant concentrations: Lack of classical dose-response relationships.

    Science.gov (United States)

    Simonin, Marie; Martins, Jean M F; Le Roux, Xavier; Uzu, Gaëlle; Calas, Aude; Richaume, Agnès

    2017-03-01

    Titanium-dioxide nanoparticles (TiO 2 -NPs) are increasingly released in agricultural soils through, e.g. biosolids, irrigation or nanoagrochemicals. Soils are submitted to a wide range of concentrations of TiO 2 -NPs depending on the type of exposure. However, most studies have assessed the effects of unrealistically high concentrations, and the dose-response relationships are not well characterized for soil microbial communities. Here, using soil microcosms, we assessed the impact of TiO 2 -NPs at concentrations ranging from 0.05 to 500 mg kg -1  dry-soil, on the activity and abundance of ammonia-oxidizing archaea (AOA) and bacteria (AOB), and nitrite-oxidizing bacteria (Nitrobacter and Nitrospira). In addition, aggregation and oxidative potential of TiO 2 -NPs were measured in the spiking suspensions, as they can be important drivers of TiO 2 -NPs toxicity. After 90 days of exposure, non-classical dose-response relationships were observed for nitrifier abundance or activity, making threshold concentrations impossible to compute. Indeed, AOA abundance was reduced by 40% by TiO 2 -NPs whatever the concentration, while Nitrospira was never affected. Moreover, AOB and Nitrobacter abundances were decreased mainly at intermediate concentrations nitrification was reduced by 25% at the lowest (0.05 mg kg -1 ) and the highest (100 and 500 mg kg -1 ) TiO 2 -NPs concentrations. Path analyses indicated that TiO 2 -NPs affected nitrification through an effect on the specific activity of nitrifiers, in addition to indirect effects on nitrifier abundances. Altogether these results point out the need to include very low concentrations of NPs in soil toxicological studies, and the lack of relevance of classical dose-response tests and ecotoxicological dose metrics (EC50, IC50…) for TiO 2 -NPs impact on soil microorganisms.

  4. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    Science.gov (United States)

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  5. Opportunities for Cancer-relevant Innovative Technologies with Transformative Potential | Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    The National Cancer Institute (NCI) is seeking input from the community on identifying priorities with regards to supporting innovative technology development for cancer-relevant research. While the NCI provides support for technology development through a variety of mechanisms, it is important to understand whether or not these are sufficient for catalyzing and supporting the development of tools with significant potential for advancing important fields of cancer research or clinical care.

  6. Perspectives on creating clinically relevant blast models for mild traumatic brain injury and post traumatic stress disorder symptoms

    Directory of Open Access Journals (Sweden)

    Lisa eBrenner

    2012-03-01

    Full Text Available Military personnel are returning from Iraq and Afghanistan and reporting non-specific physical (somatic, behavioral, psychological, and cognitive symptoms. Many of these symptoms are frequently associated with mild traumatic brain injury (mTBI and/or post traumatic stress disorder (PTSD. Despite significant attention and advances in assessment and intervention for these two conditions, challenges persist. To address this, clinically relevant blast models are essential in the full characterization of this type of injury, as well as in the testing and identification of potential treatment strategies. In this publication, existing diagnostic challenges and current treatment practices for mTBI and/or PTSD will be summarized, along with suggestions regarding how what has been learned from existing models of PTSD and traditional mechanism (e.g., non-blast TBI can be used to facilitate the development of clinically relevant blast models.

  7. TH-A-19A-09: Towards Sub-Second Proton Dose Calculation On GPU

    Energy Technology Data Exchange (ETDEWEB)

    Silva, J da [University of Cambridge, Cambridge, Cambridgeshire (United Kingdom)

    2014-06-15

    Purpose: To achieve sub-second dose calculation for clinically relevant proton therapy treatment plans. Rapid dose calculation is a key component of adaptive radiotherapy, necessary to take advantage of the better dose conformity offered by hadron therapy. Methods: To speed up proton dose calculation, the pencil beam algorithm (PBA; clinical standard) was parallelised and implemented to run on a graphics processing unit (GPU). The implementation constitutes the first PBA to run all steps on GPU, and each part of the algorithm was carefully adapted for efficiency. Monte Carlo (MC) simulations obtained using Fluka of individual beams of energies representative of the clinical range impinging on simple geometries were used to tune the PBA. For benchmarking, a typical skull base case with a spot scanning plan consisting of a total of 8872 spots divided between two beam directions of 49 energy layers each was provided by CNAO (Pavia, Italy). The calculations were carried out on an Nvidia Geforce GTX680 desktop GPU with 1536 cores running at 1006 MHz. Results: The PBA reproduced within ±3% of maximum dose results obtained from MC simulations for a range of pencil beams impinging on a water tank. Additional analysis of more complex slab geometries is currently under way to fine-tune the algorithm. Full calculation of the clinical test case took 0.9 seconds in total, with the majority of the time spent in the kernel superposition step. Conclusion: The PBA lends itself well to implementation on many-core systems such as GPUs. Using the presented implementation and current hardware, sub-second dose calculation for a clinical proton therapy plan was achieved, opening the door for adaptive treatment. The successful parallelisation of all steps of the calculation indicates that further speedups can be expected with new hardware, brightening the prospects for real-time dose calculation. This work was funded by ENTERVISION, European Commission FP7 grant 264552.

  8. TH-A-19A-09: Towards Sub-Second Proton Dose Calculation On GPU

    International Nuclear Information System (INIS)

    Silva, J da

    2014-01-01

    Purpose: To achieve sub-second dose calculation for clinically relevant proton therapy treatment plans. Rapid dose calculation is a key component of adaptive radiotherapy, necessary to take advantage of the better dose conformity offered by hadron therapy. Methods: To speed up proton dose calculation, the pencil beam algorithm (PBA; clinical standard) was parallelised and implemented to run on a graphics processing unit (GPU). The implementation constitutes the first PBA to run all steps on GPU, and each part of the algorithm was carefully adapted for efficiency. Monte Carlo (MC) simulations obtained using Fluka of individual beams of energies representative of the clinical range impinging on simple geometries were used to tune the PBA. For benchmarking, a typical skull base case with a spot scanning plan consisting of a total of 8872 spots divided between two beam directions of 49 energy layers each was provided by CNAO (Pavia, Italy). The calculations were carried out on an Nvidia Geforce GTX680 desktop GPU with 1536 cores running at 1006 MHz. Results: The PBA reproduced within ±3% of maximum dose results obtained from MC simulations for a range of pencil beams impinging on a water tank. Additional analysis of more complex slab geometries is currently under way to fine-tune the algorithm. Full calculation of the clinical test case took 0.9 seconds in total, with the majority of the time spent in the kernel superposition step. Conclusion: The PBA lends itself well to implementation on many-core systems such as GPUs. Using the presented implementation and current hardware, sub-second dose calculation for a clinical proton therapy plan was achieved, opening the door for adaptive treatment. The successful parallelisation of all steps of the calculation indicates that further speedups can be expected with new hardware, brightening the prospects for real-time dose calculation. This work was funded by ENTERVISION, European Commission FP7 grant 264552

  9. Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up. A cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Braat, Arthur J.A.T.; Prince, Jip F.; Rooij, Rob van; Bruijnen, Rutger C.G.; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands)

    2018-03-15

    Radioembolisation is generally preceded by a scout dose of technetium-99m-macroaggregated albumin to estimate extrahepatic shunting of activity. Holmium-166 microspheres can be used as a scout dose (±250 MBq) and as a therapeutic dose. The general toxicity of a holmium-166 scout dose ({sup 166}Ho-SD) and safety concerns of an accidental extrahepatic deposition of {sup 166}Ho-SD were investigated. All patients who received a {sup 166}Ho-SD in our institute were reviewed for general toxicity and extrahepatic depositions. The absorbed dose in extrahepatic tissue was calculated on SPECT/CT and correlated to clinical toxicities. In total, 82 patients were included. No relevant clinical toxicity occurred. Six patients had an extrahepatic deposition of {sup 166}Ho-SD (median administered activity 270 MBq). The extrahepatic depositions (median activity 3.7 MBq) were located in the duodenum (3x), gastric fundus, falciform ligament and the lesser curvature of the stomach, and were deposited in a median volume of 15.3 ml, which resulted in an estimated median absorbed dose of 3.6 Gy (range 0.3-13.8 Gy). No adverse events related to the extrahepatic deposition of the {sup 166}Ho-SD occurred after a median follow-up of 4 months (range 1-12 months). These results support the safety of 250 MBq {sup 166}Ho-SD in a clinical setting. (orig.)

  10. Clinical empathy and narrative competence: the relevance of reading talmudic legends as literary fiction.

    Science.gov (United States)

    Davidson, John H

    2015-04-01

    The "curative potential" in almost any clinical setting depends on a caregiver establishing and maintaining an empathic connection with patients so as to achieve "narrative competence" in discerning and acting in accord with their preferences and best interests. The "narrative medicine" model of shared "close reading of literature and reflective writing" among clinicians as a means of fostering a capacity for clinical empathy has gained validation with recent empirical studies demonstrating the enhancement of theory of mind (ToM), broadly conceived as empathy, in readers of literary fiction. Talmudic legends, like that of Rabbi Judah's death, are under-appreciated, relevant sources of literary fiction for these efforts. The limitations of narrative medicine are readily counterbalanced by simultaneously practiced attention to traditional bioethical principles, including-especially-beneficence, non-maleficence, and autonomy.

  11. Bottom–up protein identifications from microliter quantities of individual human tear samples. Important steps towards clinical relevance.

    Directory of Open Access Journals (Sweden)

    Peter Raus

    2015-12-01

    With 375 confidently identified proteins in the healthy adult tear, the obtained results are comprehensive and in large agreement with previously published observations on pooled samples of multiple patients. We conclude that, to a limited extent, bottom–up tear protein identifications from individual patients may have clinical relevance.

  12. Clinical study of a new therapy for nerve agent poisoning: Ascending dose tolerance study of HI-6 + atropine

    Energy Technology Data Exchange (ETDEWEB)

    Clement, J.G.; Bailey, D.G.; Madill, H.D.; Spence, J.D.

    1993-05-13

    HI-6 was rapidly absorbed from an IM injection site. Maximum HI-6 plasma concentrations of 1.88, 4.96, 8.31 15.0 ug/ml were found 28-36 min after administration and maintained above 4 ug/ml concentration for 0, 39, 112 172.5 min following administration of 62.5, 125, 250 or 500 mg HI-6 + atropine (2 mg), respectively. The calculated half life of HI-6 was 78.2 min following 62.5 mg HI-6 + atropine dose and approximately 64-67 min following 125-500 mg HI-6 + atropine doses. Approximately 50 % of the total dose of HI-6 was eliminated unchanged in the urine. There were significant changes (p < 0.05) in AST, CPK, creatinine and gamma GT following the 500 mg HI-6 + atropine dose but they were not considered to be clinically significant. Urinalysis, hematology and semen analysis over the 24 hr observation period was uneventful. There were no clinically significant changes in heart rate or ECG trace, respiration or blood pressure, visual and mental acuity following HI-6 + atropine.

  13. Clinical relevance of the gap between pre-marketing trials and medical practice : the case of the cardiovascular drugs

    NARCIS (Netherlands)

    Wieringa, N F; Denig, P; de Graeff, P A; Vos, R

    OBJECTIVES/BACKGROUND: The external validity of trial results of new cardiovascular drugs is limited, because the short-term studies are performed with relatively small, highly selected populations. Using qualitative methods, we examined the clinical relevance of under-representation of subgroups of

  14. Efficacy and Safety of Daikenchuto for Constipation and Dose-Dependent Differences in Clinical Effects.

    Science.gov (United States)

    Hirose, Tatsuya; Shinoda, Yasutaka; Kuroda, Ayaka; Yoshida, Aya; Mitsuoka, Machiko; Mori, Kouki; Kawachi, Yuki; Moriya, Akihiro; Tanaka, Kouji; Takeda, Atsuko; Yoshimura, Tomoaki; Sugiyama, Tadashi

    2018-01-01

    Daikenchuto (DKT) is a Kampo medicine used for the treatment of constipation. In this study, we evaluated the effectiveness of DKT against constipation. Thirty-three patients administered DKT for constipation were selected and divided into low-dose (7.5 g DKT; n = 22) and high-dose (15 g DKT; n = 11) groups. We retrospectively evaluated weekly defaecation frequency, side effects, and clinical laboratory data. Median defaecation frequencies after DKT administration (5, 5.5, 5, and 8 for the first, second, third, and fourth weeks, resp.) were significantly higher than that before DKT administration (2) in all 33 cases ( P DKT increases defaecation frequency and is safe for treating constipation.

  15. [Relevance of Vascular Trauma in Trauma Care - Impact on Clinical Course and Mortality].

    Science.gov (United States)

    Lech, L; Jerkku, T; Kanz, K-G; Wierer, M; Mutschler, W; Koeppel, T A; Lefering, R; Banafsche, R

    2016-10-01

    There is a lack of evidence as to the relevance of vascular trauma (VT) in patients with severe injuries. Therefore, we reviewed registry data in the present study in order to systematically objectify the effect of VT in these patients. This study aimed to provide an adequate picture of the relevance of vascular trauma and to identify adverse prognostic factors. In a retrospective analysis of records from the TraumaRegister DGU® (TR-DGU) in two subgroups with moderate and severe VT, we examined the records for differences in terms of morbidity, mortality, follow-up and prognostic parameters compared to patients without VT with the same ISS. From a total of 42,326 patients, 2,961 (7 %) had a VT, and in 2,437 cases a severe VT (AIS ≥ 3) was diagnosed (5.8 %). In addition to a higher incidence of shock and a 2 to 3-fold increase in fluid replacement and erythrocyte transfusion, patients with severe VT had a 60 % higher rate of multiple organ failure, and in-hospital mortality was twice as high (33.8 %). The massively increased early mortality (8.0 vs. 25.2 %) clearly illustrates how severely injured patients are placed at risk by the presence of a relevant VT with a comparable ISS. In our opinion, due to an unexpected poor prognosis in the TR-DGU data for vascular injuries, increased attention is required in the care of severely injured patients. Based on our comprehensive analysis of negative prognostic factors, a further adjustment to the standards of vascular medicine could be advisable. The influence of the level of care provided by the admitting hospital and the relevance of a further hospital transfer to prognosis and clinical outcome is currently being analysed. Georg Thieme Verlag KG Stuttgart · New York.

  16. The Importance of Integrating Clinical Relevance and Statistical Significance in the Assessment of Quality of Care--Illustrated Using the Swedish Stroke Register.

    Directory of Open Access Journals (Sweden)

    Anita Lindmark

    Full Text Available When profiling hospital performance, quality inicators are commonly evaluated through hospital-specific adjusted means with confidence intervals. When identifying deviations from a norm, large hospitals can have statistically significant results even for clinically irrelevant deviations while important deviations in small hospitals can remain undiscovered. We have used data from the Swedish Stroke Register (Riksstroke to illustrate the properties of a benchmarking method that integrates considerations of both clinical relevance and level of statistical significance.The performance measure used was case-mix adjusted risk of death or dependency in activities of daily living within 3 months after stroke. A hospital was labeled as having outlying performance if its case-mix adjusted risk exceeded a benchmark value with a specified statistical confidence level. The benchmark was expressed relative to the population risk and should reflect the clinically relevant deviation that is to be detected. A simulation study based on Riksstroke patient data from 2008-2009 was performed to investigate the effect of the choice of the statistical confidence level and benchmark value on the diagnostic properties of the method.Simulations were based on 18,309 patients in 76 hospitals. The widely used setting, comparing 95% confidence intervals to the national average, resulted in low sensitivity (0.252 and high specificity (0.991. There were large variations in sensitivity and specificity for different requirements of statistical confidence. Lowering statistical confidence improved sensitivity with a relatively smaller loss of specificity. Variations due to different benchmark values were smaller, especially for sensitivity. This allows the choice of a clinically relevant benchmark to be driven by clinical factors without major concerns about sufficiently reliable evidence.The study emphasizes the importance of combining clinical relevance and level of statistical

  17. The Importance of Integrating Clinical Relevance and Statistical Significance in the Assessment of Quality of Care--Illustrated Using the Swedish Stroke Register.

    Science.gov (United States)

    Lindmark, Anita; van Rompaye, Bart; Goetghebeur, Els; Glader, Eva-Lotta; Eriksson, Marie

    2016-01-01

    When profiling hospital performance, quality inicators are commonly evaluated through hospital-specific adjusted means with confidence intervals. When identifying deviations from a norm, large hospitals can have statistically significant results even for clinically irrelevant deviations while important deviations in small hospitals can remain undiscovered. We have used data from the Swedish Stroke Register (Riksstroke) to illustrate the properties of a benchmarking method that integrates considerations of both clinical relevance and level of statistical significance. The performance measure used was case-mix adjusted risk of death or dependency in activities of daily living within 3 months after stroke. A hospital was labeled as having outlying performance if its case-mix adjusted risk exceeded a benchmark value with a specified statistical confidence level. The benchmark was expressed relative to the population risk and should reflect the clinically relevant deviation that is to be detected. A simulation study based on Riksstroke patient data from 2008-2009 was performed to investigate the effect of the choice of the statistical confidence level and benchmark value on the diagnostic properties of the method. Simulations were based on 18,309 patients in 76 hospitals. The widely used setting, comparing 95% confidence intervals to the national average, resulted in low sensitivity (0.252) and high specificity (0.991). There were large variations in sensitivity and specificity for different requirements of statistical confidence. Lowering statistical confidence improved sensitivity with a relatively smaller loss of specificity. Variations due to different benchmark values were smaller, especially for sensitivity. This allows the choice of a clinically relevant benchmark to be driven by clinical factors without major concerns about sufficiently reliable evidence. The study emphasizes the importance of combining clinical relevance and level of statistical confidence when

  18. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  19. Sci-Thur PM – Brachytherapy 05: Surface Collimation Applied to Superficial Flap High Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Derek; Sabondjian, Eric; Lawrence, Kailin; Sankreacha, Raxa [University of Toronto, Carlo Fidani Peel Regional Cancer Center, Carlo Fidani Peel Regional Cancer Center, University of Toronto (Canada)

    2016-08-15

    Purpose: To apply surface collimation for superficial flap HDR skin brachytherapy utilizing common clinical resources and to demonstrate the potential for OAR dose reduction within a clinically relevant setting. Methods: Two phantom setups were used. 3 mm lead collimation was applied to a solid slab phantom to determine appropriate geometries relating to collimation and dwell activation. The same collimation was applied to the temple of an anthropomorphic head phantom to demonstrate lens dose reduction. Each setup was simulated and planned to deliver 400 cGy to a 3 cm circular target to 3 mm depth. The control and collimated irradiations were sequentially measured using calibrated radiochromic films. Results: Collimation for the slab phantom attenuated the dose beyond the collimator opening, decreasing the fall-off distances by half and reducing the area of healthy skin irradiated. Target coverage can be negatively impacted by a tight collimation margin, with the required margin approximated by the primary beam geometric penumbra. Surface collimation applied to the head phantom similarly attenuated the surrounding normal tissue dose while reducing the lens dose from 84 to 68 cGy. To ensure consistent setup between simulation and treatment, additional QA was performed including collimator markup, accounting for collimator placement uncertainties, standoff distance verification, and in vivo dosimetry. Conclusions: Surface collimation was shown to reduce normal tissue dose without compromising target coverage. Lens dose reduction was demonstrated on an anthropomorphic phantom within a clinical setting. Additional QA is proposed to ensure treatment fidelity.

  20. Sci-Thur PM – Brachytherapy 05: Surface Collimation Applied to Superficial Flap High Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Liu, Derek; Sabondjian, Eric; Lawrence, Kailin; Sankreacha, Raxa

    2016-01-01

    Purpose: To apply surface collimation for superficial flap HDR skin brachytherapy utilizing common clinical resources and to demonstrate the potential for OAR dose reduction within a clinically relevant setting. Methods: Two phantom setups were used. 3 mm lead collimation was applied to a solid slab phantom to determine appropriate geometries relating to collimation and dwell activation. The same collimation was applied to the temple of an anthropomorphic head phantom to demonstrate lens dose reduction. Each setup was simulated and planned to deliver 400 cGy to a 3 cm circular target to 3 mm depth. The control and collimated irradiations were sequentially measured using calibrated radiochromic films. Results: Collimation for the slab phantom attenuated the dose beyond the collimator opening, decreasing the fall-off distances by half and reducing the area of healthy skin irradiated. Target coverage can be negatively impacted by a tight collimation margin, with the required margin approximated by the primary beam geometric penumbra. Surface collimation applied to the head phantom similarly attenuated the surrounding normal tissue dose while reducing the lens dose from 84 to 68 cGy. To ensure consistent setup between simulation and treatment, additional QA was performed including collimator markup, accounting for collimator placement uncertainties, standoff distance verification, and in vivo dosimetry. Conclusions: Surface collimation was shown to reduce normal tissue dose without compromising target coverage. Lens dose reduction was demonstrated on an anthropomorphic phantom within a clinical setting. Additional QA is proposed to ensure treatment fidelity.

  1. Incidence of radiation pneumonitis after thoracic irradiation: Dose-volume correlates

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Miller, Robert C.; Brinkmann, Debra H.; Foote, Tyler; Garces, Yolanda I.

    2007-01-01

    Purpose: To define clinical and dosimetric parameters correlated with the risk of clinically relevant radiation pneumonitis (RP) after thoracic radiotherapy. Methods and Materials: Records of consecutive patients treated with definitive thoracic radiotherapy were retrospectively reviewed for the incidence of RP of Grade 2 or greater by the Common Toxicity Criteria. Dose-volume histograms using total lung volume (TL) and TL minus gross tumor volume (TL-G) were created with and without heterogeneity corrections. Mean lung dose (MLD), effective lung volume (V eff ), and percentage of TL or TL-G receiving greater than or equal to 10, 13, 15, 20, and 30 Gy (V10-V30, respectively) were analyzed by logistic regression. Receiver operating characteristic (ROC) curves were generated to estimate RP predictive values. Results: Twelve cases of RP were identified in 92 eligible patients. Mean lung dose, V10, V13, V15, V20, and V eff were significantly correlated to RP. Combinations of MLD, V eff , V20, and V30 lost significance using TL-G and heterogeneity corrections. Receiver operating characteristic analysis determined V10 and V13 as the best predictors of RP risk, with a decrease in predictive value above those volumes. Conclusions: Intrathoracic radiotherapy should be planned with caution when using radiotherapy techniques delivering doses of 10 to 15 Gy to large lung volumes

  2. Relevance of protection quantities in medical exposures

    International Nuclear Information System (INIS)

    Pradhan, A.S.

    2008-01-01

    International Commission on Radiological Protection (ICRP) continues to classify the exposures to radiation in three categories; namely 1- occupational exposure, 2- public exposure, and 3- medical exposure. Protection quantities are primarily meant for the regulatory purpose in radiological protection for controlling and limiting stochastic risks in occupational and public exposures. These are based on two basic assumptions of 1- linear no-threshold dose-effect relationship (LNT) at low doses and 2- long-term additivity of low doses. Medical exposure are predominantly delivered to individuals (patients) undergoing diagnostic examinations, interventional procedures and radiation therapy but also include individual caring for or comforting patients incurring exposure and the volunteers of biomedical medical research programmes. Radiation protection is as relevant to occupational and public exposure as to medical exposures except that the dose limits set for the formers are not applicable to medical exposure but reference levels and dose constrains are recommended for diagnostic and interventional medical procedures. In medical institutions, both the occupational and medical exposure takes place. Since the doses in diagnostic examinations are low, it has been observed that not only the protection quantities are often used in such cases but these are extended to estimate the number of cancer deaths due to such practices. One of the striking features of the new ICRP recommendations has been to elaborate the concepts of the dosimetric quantities. The limitation of protection quantities ((Effective dose, E=Σ RT D TR .W T .W R and Equivalent Dose H T =Σ RT D TR .W R ) have been brought out and this has raised a great concern and initiated debates on the use of these quantities in medical exposures. Consequently, ICRP has set a task group to provide more details and the recommendations. It has, therefore, became important to draw the attention of medical physics community

  3. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Scott and White Healthcare System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  4. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2016-01-01

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  5. Modelling of an industrial environment, part 2.: External dose calculation with relevant countermeasures

    International Nuclear Information System (INIS)

    Eged, K.; Kis, Z.; Alvarez-Farizo, B.; Gil, J.; Voigt, G.

    2002-01-01

    The calculation of the collective dose and averted collective dose after applying countermeasures in an industrial environment has been divided in two parts. In the first part (Kis et al. 2002) separate Monte Carlo simulations of photon transport resulted in the air kermas per photon per unit area due to the industrial surfaces contaminated by 1 37C s at specific points using the so-called local approach. In the local approach the air kerma rates due to specific intervention elements at the evaluation locations in the whole environment are determined (Gutierrez et al. 2000). In this way the collective and averted collective dose due to the radiation from a particular intervention element (e.g. the roof of a building) can be obtained. It can, therefore, provide a ranking of the specific intervention elements based on their contribution to collective dose as well. The deposition pattern and the long-term behaviour of deposited radionuclides vary widely in natural circumstances; therefore the number of the photons emitted from the various surfaces per unit area and time can differ significantly. This means the results of the Monte Carlo simulations have to be weighted according to the number of emitted photons so that the actual radiation field can be set up. For this purpose, a dose calculation code has been developed in the framework of the TEMAS project (Gutierrez et al. 2000) which allows to calculate collective doses for different environments. This code has been applied in the present work

  6. Prognostic Relevance of Immunohistochemical Subclassification of Diffuse Large B-Cell Lymphoma in Two Prospective Phase III Clinical Trials

    NARCIS (Netherlands)

    Rayman, Nazik; Lam, King H.; van der Holt, Bronno; Koss, Clara; Veldhuizen, Dennis; Budel, Leo M.; Mulder, Andries H.; Verdonck, Leo F.; Delwel, Ruud; de Jong, Daphne; van Imhoff, Gustaaf W.; Sonneveld, Pieter

    Purpose: Until now molecular biologic techniques have not been easily used in daily clinical practice to stratify patients for therapeutic purposes. Therefore, we have investigated the prognostic relevance of the immunohistochemical (IHC) germinal center B-cell (GCB) versus non-GCB diffuse large

  7. Comparative analysis of three drug-drug interaction screening systems against probable clinically relevant drug-drug interactions: a prospective cohort study.

    Science.gov (United States)

    Muhič, Neža; Mrhar, Ales; Brvar, Miran

    2017-07-01

    Drug-drug interaction (DDI) screening systems report potential DDIs. This study aimed to find the prevalence of probable DDI-related adverse drug reactions (ADRs) and compare the clinical usefulness of different DDI screening systems to prevent or warn against these ADRs. A prospective cohort study was conducted in patients urgently admitted to medical departments. Potential DDIs were checked using Complete Drug Interaction®, Lexicomp® Online™, and Drug Interaction Checker®. The study team identified the patients with probable clinically relevant DDI-related ADRs on admission, the causality of which was assessed using the Drug Interaction Probability Scale (DIPS). Sensitivity, specificity, and positive and negative predictive values of screening systems to prevent or warn against probable DDI-related ADRs were evaluated. Overall, 50 probable clinically relevant DDI-related ADRs were found in 37 out of 795 included patients taking at least two drugs, most common of them were bleeding, hyperkalemia, digitalis toxicity, and hypotension. Complete Drug Interaction showed the best sensitivity (0.76) for actual DDI-related ADRs, followed by Lexicomp Online (0.50), and Drug Interaction Checker (0.40). Complete Drug Interaction and Drug Interaction Checker had positive predictive values of 0.07; Lexicomp Online had 0.04. We found no difference in specificity and negative predictive values among these systems. DDI screening systems differ significantly in their ability to detect probable clinically relevant DDI-related ADRs in terms of sensitivity and positive predictive value.

  8. Clinically relevant radioresistant cells efficiently repair DNA double-strand breaks induced by X-rays

    International Nuclear Information System (INIS)

    Kuwahara, Yoshikazu; Baba, Taisuke; Nakagawa, Hironobu; Shimura, Tsutomu; Yamamoto, Yoichiro; Fukumoto, Manabu; Li Li; Ohkubo, Yasuhito

    2009-01-01

    Radiotherapy is one of the major therapeutic modalities for eradicating malignant tumors. However, the existence of radioresistant cells remains one of the most critical obstacles in radiotherapy and radiochemotherapy. Standard radiotherapy for tumor treatment consists of approximately 2 Gy once a day, 5 days a week, over a period of 5-8 weeks. To understand the characteristics of radioresistant cells and to develop more effective radiotherapy, we established a novel radioresistant cell line, HepG2-8960-R with clinical relevance from parental HepG2 cells by long-term fractionated exposure to 2 Gy of X-rays. HepG2-8960-R cells continued to proliferate with daily exposure to 2 Gy X-rays for more than 30 days, while all parental HepG2 cells ceased. After exposure to fractionated 2 Gy X-rays, induction frequencies of micronuclei and remaining foci of γ-H2AX in HepG2-8960-R were less than those in HepG2. Flow cytometric analysis revealed that the proportion of cells in S- and G2/M-phase of the cell cycle was higher in HepG2-8960-R than in HepG2. These suggest that the response of clinically relevant radioresistant (CRR) cells to fractionated radiation is not merely an accumulated response to each fractionated radiation. This is the first report on the establishment of a CRR cell line from an isogenic parental cell line. (author)

  9. Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

    Science.gov (United States)

    Chamberland, Eve; Beaulieu, Luc; Lachance, Bernard

    2015-05-08

    The purpose of this study is to evaluate the accuracy of the electron Monte Carlo (eMC) dose calculation algorithm included in a commercial treatment planning system and compare its performance against an electron pencil beam algorithm. Several tests were performed to explore the system's behavior in simple geometries and in configurations encountered in clinical practice. The first series of tests were executed in a homogeneous water phantom, where experimental measurements and eMC-calculated dose distributions were compared for various combinations of energy and applicator. More specifically, we compared beam profiles and depth-dose curves at different source-to-surface distances (SSDs) and gantry angles, by using dose difference and distance to agreement. Also, we compared output factors, we studied the effects of algorithm input parameters, which are the random number generator seed, as well as the calculation grid size, and we performed a calculation time evaluation. Three different inhomogeneous solid phantoms were built, using high- and low-density materials inserts, to clinically simulate relevant heterogeneity conditions: a small air cylinder within a homogeneous phantom, a lung phantom, and a chest wall phantom. We also used an anthropomorphic phantom to perform comparison of eMC calculations to measurements. Finally, we proceeded with an evaluation of the eMC algorithm on a clinical case of nose cancer. In all mentioned cases, measurements, carried out by means of XV-2 films, radiographic films or EBT2 Gafchromic films. were used to compare eMC calculations with dose distributions obtained from an electron pencil beam algorithm. eMC calculations in the water phantom were accurate. Discrepancies for depth-dose curves and beam profiles were under 2.5% and 2 mm. Dose calculations with eMC for the small air cylinder and the lung phantom agreed within 2% and 4%, respectively. eMC calculations for the chest wall phantom and the anthropomorphic phantom also

  10. Environmental biodosimetry: a biologically relevant tool for ecological risk assessment and biomonitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ulsh, B. E-mail: ulshb@mcmaster.ca; Hinton, T.G.; Congdon, J.D.; Dugan, L.C.; Whicker, F.W.; Bedford, J.S

    2003-07-01

    Biodosimetry, the estimation of received doses by determining the frequency of radiation-induced chromosome aberrations, is widely applied in humans acutely exposed as a result of accidents or for clinical purposes, but biodosimetric techniques have not been utilized in organisms chronically exposed to radionuclides in contaminated environments. The application of biodosimetry to environmental exposure scenarios could greatly improve the accuracy, and reduce the uncertainties, of ecological risk assessments and biomonitoring studies, because no assumptions are required regarding external exposure rates and the movement of organisms into and out of contaminated areas. Furthermore, unlike residue analyses of environmental media environmental biodosimetry provides a genetically relevant biomarker of cumulative lifetime exposure. Symmetrical chromosome translocations can impact reproductive success, and could therefore prove to be ecologically relevant as well. We describe our experience in studying aberrations in the yellow-bellied slider turtle as an example of environmental biodosimetry.

  11. Clinical Empathy and Narrative Competence: The Relevance of Reading Talmudic Legends as Literary Fiction

    Directory of Open Access Journals (Sweden)

    John H. Davidson

    2015-04-01

    Full Text Available The “curative potential” in almost any clinical setting depends on a caregiver establishing and maintaining an empathic connection with patients so as to achieve “narrative competence” in discerning and acting in accord with their preferences and best interests. The “narrative medicine” model of shared “close reading of literature and reflective writing” among clinicians as a means of fostering a capacity for clinical empathy has gained validation with recent empirical studies demonstrating the enhancement of theory of mind (ToM, broadly conceived as empathy, in readers of literary fiction. Talmudic legends, like that of Rabbi Judah’s death, are under-appreciated, relevant sources of literary fiction for these efforts. The limitations of narrative medicine are readily counterbalanced by simultaneously practiced attention to traditional bioethical principles, including—especially—beneficence, non-maleficence, and autonomy.

  12. Reflections on relevance: Psychotherapy and Psychosomatics in 2004.

    Science.gov (United States)

    Balon, Richard

    2005-01-01

    Relevance of an article is a highly desirable yet hardly predictable quality at the time of its publication. Article relevance is frequently measured by the impact factor of the journal where the article is published. Furthermore, impact factor, citation index and citation analysis are used as a measure of research progress and scientific wealth of a nation. The wisdom and significance of this approach to relevance is debatable and thus discussed here. In 2004, Psychotherapy and Psychosomatics published a variety of articles which, in the author's view, are clinically relevant. Several selected clinically relevant issues reviewed in this article include: the conceptualization of fibromyalgia as a stress disorder; the psychosocial impact and psychosocial interventions in cancer; the impact of alexithymia on patient care; the possible relationship between depression and nutrition (namely intake of folate and pyridoxal phosphate); the significance of hypercoagulability in panic-like anxiety; the questionable value of single isomer drugs, and the relevance and adequacy of clinimetrics versus psychometrics in clinical research. The reviewed issues seem to be relevant to clinical practice, research or both, but also to our critical thinking, and the critical review of the developments in psychiatry and psychology. Copyright 2005 S. Karger AG, Basel.

  13. Response of pig skin to fractionated radiation doses

    International Nuclear Information System (INIS)

    Wiernik, G.; Hopewell, J.W.; Patterson, T.J.S.; Young, C.M.A.; Foster, J.L.

    1977-01-01

    The individual components of a fractionated course of irradiation treatment have been considered separately. Methods of accurate measurement of individual parameters has brought to light different interpretations of the observations. Reasons are given for the necessity of having a radiobiological model which has a direct relevance to the clinical situation. Results are reported for fractionated regimes of irradiation in which the dose has been varied above and below normal tissue tolerance which has been equated with clinical skin necrosis. The components of the acute skin reaction, erythema, pigmentation and desquamation have been analysed separately and their contribution as a method of measurement assessed. Initially, the range of numerical scores attributed to erythema did not reach the scores attributed to necrosis but we now believe that radiation damage expressed as erythema can move directly into necrosis without passing through desquamation. Desquamation, on the other hand, only became a useful parameter at higher dose levels; it has also been shown to be a component associated with skin breakdown. Pigmentation showed no dose response at the dose levels employed in our experiments and it is our belief that this is due to this system being fully saturated under these circumstances. Measurement of the late radiation reaction in the skin has been considered in detail and our results have been expressed by comparing the relative lengths of irradiated and control fields in the same pig. From these findings iso-effect graphs have been constructed and time and fractionation factors have been derived. (author)

  14. Clinical Strategy for Optimal Traditional Chinese Medicine (TCM) Herbal Dose Selection in Disease Therapeutics: Expert Consensus on Classic TCM Herbal Formula Dose Conversion.

    Science.gov (United States)

    Zha, Lin-Hua; He, Li-Sha; Lian, Feng-Mei; Zhen, Zhong; Ji, Hang-Yu; Xu, Li-Peng; Tong, Xiao-Lin

    2015-01-01

    The clinical therapeutics of traditional Chinese medicine (TCM) constitutes a complicated process which involves theory, diagnosis, and formula prescription with specific herbal dosage. Zhang Zhong-Jing's classic work, Treatise on Febrile and Miscellaneous Diseases, has been influencing TCM practice for almost 2000 years. However, during this extended period of time in Chinese history, the Chinese weight measurement system experienced noticeable changes. This change in the weight measurement system inevitably, and perhaps even negatively, affected TCM herbal dosage determination and treatment outcome. Thus, in modern society, a full understanding of the accuracy of herbal dose selection has a critical importance in the TCM daily practice of delivering the best treatment to the patients suffering from different illnesses. In the 973 Project of the Chinese National Basic Research Program, expert consensus on classic TCM formula dose conversion has been reached based on extensive literature review and discussion on the dose-effect relationship of classic TCM formulas. One "liang" in classic TCM formulas is equivalent to 13.8 g. However, based on many TCM basic and clinical studies of variable herbal formula prescriptions and herbal drug preparations, the rule of one liang equals 13.8 g should be adjusted according to different disease conditions. Recommended by the committee on TCM formula dose-effect relationship of the China Association of Chinese Medicine and the World Federation of Chinese Medicine Societies, the following expert consensus has been reached: (i) One liang converts to 6-9 g for the severely and critically ill patients. (ii) One liang converts to 3-6 g for the patients suffering from chronic diseases. (iii) One liang converts to 1-3 g in preventive medicine. The above conversions should be used as a future TCM practice guideline. Using this recommended guideline should enhance the effectiveness of daily TCM practice.

  15. SU-F-T-93: Breast Surface Dose Enhancement Using a Clinical Prone Breast Board

    International Nuclear Information System (INIS)

    Guerra, M; Jozsef, G

    2016-01-01

    Purpose: The use of specialized patient set-up devices in radiotherapy, such as prone breast boards, may have unwanted dosimetric effects. The goal of this study was to evaluate the effect of a clinically used prone breast board on skin dose due to buildup. Methods: GafChromic film (EBT3) was used for dose measurements on the surface of a solid water phantom shaped to mimic the curvature of the breast. We investigated two setup scenarios: the medial field border placed at the medial edge of the board and 1 cm contralaterally from that edge. A strip of film was taped to the medial surface of the phantom. Gantry angles varied from 10 to 30 degrees below the lateral gantry position, representing anterior oblique fields. The measurements were performed with and without the presence of the board; the ratio of their corresponding doses (dose enhancement) was evaluated. Results: For the cases where the field edge is at the edge of the board, the dose enhancement is negligible for all the tested angles. When the field edge is 1 cm inside the board, the maximum surface dose enhancement varies depending on the gantry angle between 2.2 for 30 degrees and 3.2 for 20 degrees. The length on the film at which the presence of the board is detectable (i.e. where there is dose enhancement) is longer for the shallower angles. Conclusion: Even the low-density, thin carbon fiber board with a thin soft foam pad on the top can produce significant dose enhancement on the skin in prone breast treatment due to loss of buildup. However, it happens only when the patient mid-sternum is over the board, i.e. the medial edge of the field traverses through the board and pad. Even then, the effect occurs only at the field edge, i.e. the penumbral region.

  16. Extracting the normal lung dose–response curve from clinical DVH data: a possible role for low dose hyper-radiosensitivity, increased radioresistance

    International Nuclear Information System (INIS)

    Gordon, J J; Snyder, K; Zhong, H; Barton, K; Sun, Z; Chetty, I J; Matuszak, M; Ten Haken, R K

    2015-01-01

    In conventionally fractionated radiation therapy for lung cancer, radiation pneumonitis’ (RP) dependence on the normal lung dose-volume histogram (DVH) is not well understood. Complication models alternatively make RP a function of a summary statistic, such as mean lung dose (MLD). This work searches over damage profiles, which quantify sub-volume damage as a function of dose. Profiles that achieve best RP predictive accuracy on a clinical dataset are hypothesized to approximate DVH dependence.Step function damage rate profiles R(D) are generated, having discrete steps at several dose points. A range of profiles is sampled by varying the step heights and dose point locations. Normal lung damage is the integral of R(D) with the cumulative DVH. Each profile is used in conjunction with a damage cutoff to predict grade 2 plus (G2+) RP for DVHs from a University of Michigan clinical trial dataset consisting of 89 CFRT patients, of which 17 were diagnosed with G2+ RP.Optimal profiles achieve a modest increase in predictive accuracy—erroneous RP predictions are reduced from 11 (using MLD) to 8. A novel result is that optimal profiles have a similar distinctive shape: enhanced damage contribution from low doses (<20 Gy), a flat contribution from doses in the range ∼20–40 Gy, then a further enhanced contribution from doses above 40 Gy. These features resemble the hyper-radiosensitivity / increased radioresistance (HRS/IRR) observed in some cell survival curves, which can be modeled using Joiner’s induced repair model.A novel search strategy is employed, which has the potential to estimate RP dependence on the normal lung DVH. When applied to a clinical dataset, identified profiles share a characteristic shape, which resembles HRS/IRR. This suggests that normal lung may have enhanced sensitivity to low doses, and that this sensitivity can affect RP risk. (paper)

  17. Doses and fractionation schemes to be employed in clinical trials of high-LET radiations

    International Nuclear Information System (INIS)

    Fowler, J.F.

    1979-01-01

    An improvement in local tumour control of 20% would require 2 x 130 cases in order that nine trials out of ten should show the difference at a significant level. If the improvement is 30% only 2 x 55 patients are required. However, the detection of increased normal tissue complications requires larger number of patients than this, e.g. 2 x 150 if the increase is from 5% to 15%. The use of two dose levels on the neutron side in a clinical trial would enable definitive data to be obtained in, say, 6 years with 300 patients, instead of 10 years with 400 patients if only one dose level were used. (author)

  18. Clinical Relevance of HLA Gene Variants in HBV Infection

    Directory of Open Access Journals (Sweden)

    Li Wang

    2016-01-01

    Full Text Available Host gene variants may influence the natural history of hepatitis B virus (HBV infection. The human leukocyte antigen (HLA system, the major histocompatibility complex (MHC in humans, is one of the most important host factors that are correlated with the clinical course of HBV infection. Genome-wide association studies (GWASs have shown that single nucleotide polymorphisms (SNPs near certain HLA gene loci are strongly associated with not only persistent HBV infection but also spontaneous HBV clearance and seroconversion, disease progression, and the development of liver cirrhosis and HBV-related hepatocellular carcinoma (HCC in chronic hepatitis B (CHB. These variations also influence the efficacy of interferon (IFN and nucleot(side analogue (NA treatment and response to HBV vaccines. Meanwhile, discrepant conclusions were reached with different patient cohorts. It is therefore essential to identify the associations of specific HLA allele variants with disease progression and viral clearance in chronic HBV infection among different ethnic populations. A better understanding of HLA polymorphism relevance in HBV infection outcome would enable us to elucidate the roles of HLA SNPs in the pathogenesis and clearance of HBV in different areas and ethnic groups, to improve strategies for the prevention and treatment of chronic HBV infection.

  19. Surface doses under head and neck immobilisation devices

    International Nuclear Information System (INIS)

    Baveas, E.

    2004-01-01

    attributed to differences in the amount and spatial variation of the stretching which occurs in the three materials in the moulding process. Film was used to demonstrate qualitatively the distinct spatial variation of the skin dose under the two posicast masks. For a posterior beam passing through the back support used with the Sinmed masks, the surface dose was measured as 68 % of Dmax, which provided an explanation for the observed erythema on the posterior skin when parallel opposed anterior and posterior supraclavicular fields were used clinically with this system. The results from this study and due consideration of other factors relevant to the clinical use of these devices led to the adoption of the multi-perforated posicast immobilisation mask as the preferred system for routine head and neck treatments at the Royal Brisbane and Women's Hospital. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  20. Three dimensional dose verification for clinical treatments of small intracranial tumours

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dunn, L.; Kairn, L.; Jenny, J.; Knight, R.; Trapp, J.; Smith, R.; Ackerly, T.

    2010-01-01

    Full text: Cancers of the brain and central nervous system account for 1.6% of new cancers and 1.8% of cancer deaths globally. The highest rates of all developed nations are observed in Australia and New Zealand. There are known complexities associated with dose measurement of very small radiation fields. Here, 3D dosimetric verification of treatments for small intracranial tumours using gel dosimetry was investigated. An anthropomorphic head phantom with a 43 mm diameter and 63 mm long gel container was filled with PAGAT normoxic radiosensitive gel. In this work, we show results for a 12-field stereotactic radiotherapy treatment delivered using a Varian 21EX with BrainLAB mini-multi leaf collimator. The gel was read out using an Octopus-1Q laser optical CT scanner. Generally good agreement was observed between the measured doses and those calculated with the iPlan treatment planning system (pencil beam convolution); see Fig. I. For gamma criteria of 5%/5 mm the percentage of gamma values less than unity was 95% above the 80% isodose line, indicating good PTV coverage. For lower isodose regions approaching the boundaries of the container poorer agreement was observed. The feasibility of three-dimensional measurement of small field dose distributions in clinical contexts has been demonstrated. Development of this methodology has the potential to overcome many shortcomings of other dosimetric methods, such as limitations of spatial information (typically one- and two-dimensions), volume-averaging effects and perturbation due to poor mediamatching. (author)

  1. Effect of specific or random c-DNA priming on sensitivity of tyrosinase nested RT-PCR : Potential clinical relevance

    NARCIS (Netherlands)

    Calogero, A; Hospers, GAP; Timmer-Bosscha, H; Mulder, NH; Schraffordt Koops, H.

    2000-01-01

    The reverse transcriptase polymerase chain reaction (RT-PCR) can be of clinical relevance in identifying malignant melanoma cells in blood or tissues of patients at risk for disseminated melanoma. The diagnostic value of this marker however, is still controversial. The objective of this study was to

  2. Short and long term bystander effect induction by fathead minnows (Pimephales promelas, Rafinesque, 1820) injected with environmentally relevant whole body doses of 226Ra

    International Nuclear Information System (INIS)

    Smith, Richard W.; Seymour, Colin B.; Mothersill, Carmel E.

    2013-01-01

    Bystander effect induction by fathead minnows injected with environmentally relevant doses of 226 Ra was investigated. Twenty four h and 6 months after injection with a single dose of 21, 210 or 2100 μBq, fin tissue samples emitted a pro-apoptotic signal, which reduced the clonogenic survival of an apoptosis sensitive reporter cell line. Twenty four h and 10 weeks after injection explants from non-injected bystander fish, swum with the injected fish, also emitted a pro-apoptotic signal. However 6 months after injection the bystander fish to 21 and 210 μBq injected fish emitted an anti-apoptotic signal. This demonstrates that extremely low dose irradiation can have effects outside of the irradiated fish. This has implications for population and ecosystem responses to contamination. -- Highlights: • Non-injected fish, swum with injected fish, gave the same response for up to 10 weeks. • After 6 months this response by non-injected fish changed to an anti-apoptotic signal. • This shows that 226 Ra contamination can have effects outside of the irradiated fish

  3. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  4. A scintillating gas detector for 2D dose measurements in clinical carbon beams.

    Science.gov (United States)

    Seravalli, E; de Boer, M; Geurink, F; Huizenga, J; Kreuger, R; Schippers, J M; van Eijk, C W E; Voss, B

    2008-09-07

    A two-dimensional position sensitive dosimetry system based on a scintillating gas detector has been developed for pre-treatment verification of dose distributions in hadron therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. The primary electrons, created in the detector's sensitive volume by the incoming beam, drift in an electric field towards the GEMs and undergo gas multiplication in the GEM holes. During this process, photons are emitted by the excited Ar/CF4 gas molecules and detected by a mirror-lens-CCD camera system. Since the amount of emitted light is proportional to the dose deposited in the sensitive volume of the detector by the incoming beam, the intensity distribution of the measured light spot is proportional to the 2D hadron dose distribution. For a measurement of a 3D dose distribution, the scintillating gas detector is mounted at the beam exit side of a water-bellows phantom, whose thickness can be varied in steps. In this work, the energy dependence of the output signal of the scintillating gas detector has been verified in a 250 MeV/u clinical 12C ion beam by means of a depth-dose curve measurement. The underestimation of the measured signal at the Bragg peak depth is only 9% with respect to an air-filled ionization chamber. This is much smaller than the underestimation found for a scintillating Gd2O2S:Tb ('Lanex') screen under the same measurement conditions (43%). Consequently, the scintillating gas detector is a promising device for verifying dose distributions in high LET beams, for example to check hadron therapy treatment plans which comprise beams with different energies.

  5. Clinical relevance of surgical site infection as defined by the criteria of the Centers for Disease Control and Prevention

    DEFF Research Database (Denmark)

    Henriksen, N A; Meyhoff, C S; Wetterslev, J

    2010-01-01

    Surgical site infection (SSI) is a common complication after abdominal surgery and the Centers for Disease Control and Prevention (CDC) criteria are commonly used for diagnosis and surveillance. The aim of this study was to evaluate whether SSI diagnosed according to CDC is clinically relevant...... diagnosed with SSI and a matched control group (N=46) without SSI according to the CDC criteria after laparotomy. Two blinded experienced surgeons evaluated the hospital records and determined whether patients had CRSSI, based on the following criteria: antibiotic treatment, surgical intervention, prolonged...... hospital stay or referral to an intensive care unit for SSI. The rate of CRSSI was 38 of 54 (70%) in patients with CDC-diagnosed SSI and none in patients without a CDC-diagnosed SSI. Sixty-one percent of the CDC-diagnosed SSIs were superficial, of which 48% were considered clinically relevant...

  6. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    Science.gov (United States)

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  7. Mechanism of Action of Prostate Stem Cell Antigen Targeted Antibody Therapy and its Relevance to Clinical Application in Prostate Cancer

    National Research Council Canada - National Science Library

    Reiter, Robert; Tran, Chau

    2008-01-01

    .... A better understanding of PSCA function and its antibody activity will enable rational patient selection and trial design all of which are particularly relevant to subsequent clinical trials of PSCA antibody...

  8. Mechanism of Action of Prostate Stem Cell Antigen Targeted Antibody Therapy and Its Relevance to Clinical Application in Prostate Cancer

    National Research Council Canada - National Science Library

    Reiter, Robert; Tran, Chau

    2007-01-01

    .... A better understanding of PSCA function and its antibody activity will enable rational patient selection and trial design, all of which are particularly relevant to subsequent clinical trials of PSCA antibody...

  9. SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Li, Z [University of Florida Health Proton Therapy Institute, Jacksonville, FL (United States); Zheng, D [University of Nebraska Medical Center, Omaha, NE (United States); Zhang, X; Narayanasamy, G; Morrill, S; Penagaricano, J; Paudel, N [University of Arkansas for Medical Sciences, Little Rock, AR (United States)

    2016-06-15

    Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in

  10. Proposed Rectal Dose Constraints for Patients Undergoing Definitive Whole Pelvic Radiotherapy for Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Chan, Linda W.; Xia Ping; Gottschalk, Alexander R.; Akazawa, Michelle; Scala, Matthew; Pickett, Barby M.S.; Hsu, I-C.; Speight, Joycelyn; Roach, Mack

    2008-01-01

    Purpose: Although several institutions have reported rectal dose constraints according to threshold toxicity, the plethora of trials has resulted in multiple, confusing dose-volume histogram recommendations. A set of standardized, literature-based constraints for patients undergoing whole pelvic radiotherapy (RT) for prostate cancer would help guide the practice of prostate RT. The purpose of this study was to develop these constraints, demonstrate that they are achievable, and assess the corresponding rectal toxicity. Methods and Materials: An extensive literature search identified eight key studies relating dose-volume histogram data to rectal toxicity. A correction factor was developed to address differences in the anatomic definition of the rectum across studies. The dose-volume histogram constraints recommended by each study were combined to generate the constraints. The data from all patients treated with definitive intensity-modulated RT were then compared against these constraints. Acute rectal toxicity was assessed. Results: A continuous, proposed rectal dose-constraint curve was generated. Intensity-modulated RT not only met this constraint curve, but also was able to achieve at least 30-40% lower dose to the rectum. The preliminary clinical results were also positive: 50% of patients reported no acute bowel toxicity, 33% reported Grade 1 toxicity, and 17% reported Grade 2 toxicity. No patients reported Grade 3-4 acute rectal toxicity. Conclusions: In this study, we developed a set of proposed rectal dose constraints. This allowed for volumetric assessment of the dose-volume relationship compared with single dose-volume histogram points. Additional research will be performed to validate this threshold as a class solution for rectal dose constraints

  11. Prenatal radiation doses from radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.M.; Di Trano, J.L.

    1998-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author) [es

  12. SU-E-T-67: Clinical Implementation and Evaluation of the Acuros Dose Calculation Algorithm

    International Nuclear Information System (INIS)

    Yan, C; Combine, T; Dickens, K; Wynn, R; Pavord, D; Huq, M

    2014-01-01

    Purpose: The main aim of the current study is to present a detailed description of the implementation of the Acuros XB Dose Calculation Algorithm, and subsequently evaluate its clinical impacts by comparing it with AAA algorithm. Methods: The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were evaluated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6cm × 6cm to 40cm × 40cm. Central axis and off-axis points with different depths were chosen for the comparison. Similarly, wedge fields with wedge angles from 15 to 60 degree were used. In addition, variable field sizes for a heterogeneous phantom were used to evaluate the Acuros algorithm. Finally, both Acuros and AAA were tested on VMAT patient plans for various sites. Does distributions and calculation time were compared. Results: On average, computation time is reduced by at least 50% by Acuros XB compared with AAA on single fields and VMAT plans. When used for open 6MV photon beams on homogeneous water phantom, both Acuros XB and AAA calculated doses were within 1% of measurement. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. When heterogeneous phantom was used, Acuros XB also improved on accuracy. Conclusion: Compared with AAA, Acuros XB can improve accuracy while significantly reduce computation time for VMAT plans

  13. Determination of the optimal minimum radioiodine dose in patients with Graves' disease: a clinical outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, D.; Tan, P.; Booker, J. [Pacific Medical Imaging, Newcastle, NSW (Australia); Epstein, M. [Dept. of Endocrinology, John Hunter Hospital, Newcastle, NSW (Australia); Lan, L. [High-Dependency Unit, St. George Hospital, Sydney, NSW (Australia)

    2001-10-01

    The study was performed under the auspices of the International Atomic Energy Commission, Vienna, Austria, with the aim of determining the optimal minimum therapeutic dose of iodine-131 for Graves' disease. The study was designed as a single-blinded randomised prospective outcome trial. Fifty-eight patients were enrolled, consisting of 50 females and 8 males aged from 17 to 75 years. Each patient was investigated by clinical assessment, biochemical and immunological assessment, thyroid ultrasound, technetium-99m thyroid scintigraphy and 24-h thyroid {sup 131}I uptake. Patients were then randomised into two treatment groups, one receiving 60 Gy and the other receiving 90 Gy thyroid tissue absorbed dose of radioiodine. The end-point markers were clinical and biochemical response to treatment. The median follow-up period was 37.5 months (range, 24-48 months). Among the 57 patients who completed final follow-up, a euthyroid state was achieved in 26 patients (46%), 27 patients (47%) were rendered hypothyroid and four patients (7%) remained hyperthyroid. Thirty-four patients (60%) remained hyperthyroid at 6 months after the initial radioiodine dose (median dose 126 MBq), and a total of 21 patients required additional radioiodine therapy (median total dose 640 MBq; range 370-1,485 MBq). At 6-month follow-up, of the 29 patients who received a thyroid tissue dose of 90 Gy, 17 (59%) remained hyperthyroid. By comparison, of the 28 patients who received a thyroid tissue dose of 60 Gy, 17 (61%) remained hyperthyroid. No significant difference in treatment response was found (P=0.881). At 6 months, five patients in the 90-Gy group were hypothyroid, compared to two patients in the 60-Gy group (P=0.246). Overall at 6 months, non-responders to low-dose therapy had a significantly larger thyroid gland mass (respective means: 35.9 ml vs 21.9 ml) and significantly higher levels of serum thyroglobulin (respective means: 597.6 {mu}g/l vs 96.9 {mu}g/l). Where low-dose radioiodine

  14. The Facts About Sexual (Dys)function in Schizophrenia: An Overview of Clinically Relevant Findings

    Science.gov (United States)

    de Boer, Marrit K.; Castelein, Stynke; Wiersma, Durk; Schoevers, Robert A.; Knegtering, Henderikus

    2015-01-01

    A limited number of studies have evaluated sexual functioning in patients with schizophrenia. Most patients show an interest in sex that differs little from the general population. By contrast, psychiatric symptoms, institutionalization, and psychotropic medication contribute to frequently occurring impairments in sexual functioning. Women with schizophrenia have a better social outcome, longer lasting (sexual) relationships, and more offspring than men with schizophrenia. Still, in both sexes social and interpersonal impairments limit the development of stable sexual relationships. Although patients consider sexual problems to be highly relevant, patients and clinicians not easily discuss these spontaneously, leading to an underestimation of their prevalence and contributing to decreased adherence to treatment. Studies using structured interviews or questionnaires result in many more patients reporting sexual dysfunctions. Although sexual functioning can be impaired by different factors, the use of antipsychotic medication seems to be an important factor. A comparison of different antipsychotics showed high frequencies of sexual dysfunction for risperidone and classical antipsychotics, and lower frequencies for clozapine, olanzapine, quetiapine, and aripiprazole. Postsynaptic dopamine antagonism, prolactin elevation, and α1-receptor blockade may be the most relevant factors in the pathogenesis of antipsychotic-induced sexual dysfunction. Psychosocial strategies to treat antipsychotic-induced sexual dysfunction include psychoeducation and relationship counseling. Pharmacological strategies include lowering the dose or switching to a prolactin sparing antipsychotic. Also, the addition of a dopamine agonist, aripiprazole, or a phosphodiesterase-5 inhibitor has shown some promising results, but evidence is currently scarce. PMID:25721311

  15. Clinical Implications of Complex Pharmacokinetics for Daratumumab Dose Regimen in Patients With Relapsed/Refractory Multiple Myeloma

    DEFF Research Database (Denmark)

    Xu, Xu Steven; Yan, Xiaoyu; Puchalski, Thomas

    2017-01-01

    New therapeutic strategies are urgently needed to improve clinical outcomes in patients with multiple myeloma (MM). Daratumumab is a first-in-class, CD38 human immunoglobulin G1κ monoclonal antibody approved for treatment of relapsed or refractory MM. Identification of an appropriate dose regimen...... for daratumumab is challenging due to its target-mediated drug disposition, leading to time- and concentration-dependent pharmacokinetics. We describe a thorough evaluation of the recommended dose regimen for daratumumab in patients with relapsed or refractory MM. This article is protected by copyright. All...

  16. Intestinal morphological effect of brachytherapy of low rate of dose, administrated in therapeutic form and its clinical manifestations in uterine cervix tumors

    International Nuclear Information System (INIS)

    Mendoza, Carmen; Contreras, Manuel

    2005-01-01

    Brachytherapy is effective to eradicate cancer in the cervix, in order to obtain the control of disease we use high dose with vesical and rectum toxicity. The objective is to investigate if brachytherapy by itself is the cause of intestinal damage, to know in addition if the intensity of the clinic manifestations is in direct relation to the given radiation dose and this gets worse when it is received in several applications. Hypothesis: The intensity of the radiation with brachytherapy of low rate of dose is proportional to the degree of clinical manifestations and morphologic damage of the intestine. A prospective analysis was made inpatients with cancer of cervix from september 2000 to june 2004. Each patient who enters to the department of brachytherapy of the hospital must be done laboratory examination that includes plaque and coagulation test before being accepted. We use the clinical card and a table in order to register data concerning teletherapy, implants of brachytherapy of low rate of dose, symptoms of intestinal toxicity and details of colonoscopia. Subsequent to the hospitable discharge the patient is sent to gastroenterology for clinical evaluation and to realize colonoscopia. From september 2000 to june 2004, 540 patients entered, 80 patients (15%) displayed intestinal manifestations, all received teletherapy and brachytherapy, nobody else received brachytherapy in exclusive form and only one patient (0.1%) received the total of the dose in 2 applications. The equipment of teletherapy Primus with energy of 6 and 18 Mv and implants of brachytherapy Manchester were used (70/55 patients). 79 (98%) patients received dose between 85-75 Gy in one single application, 58 (72%) received the total of the dose to the tumor, 21 (26%) in vaginal mucosa. Discussion: Brachytherapy is the cause of the damages in the intestinal mucosa. (The author)

  17. Diagnosing congenital malaria in a high-transmission setting: clinical relevance and usefulness of P.falciparum HRP2-based testing

    NARCIS (Netherlands)

    Natama, Hamtandi Magloire; Ouedraogo, Delwendé Florence; Sorgho, Hermann; Rovira-Vallbona, Eduard; Serra-Casas, Elisa; Somé, M. Athanase; Coulibaly-Traoré, Maminata; Mens, Petra F.; Kestens, Luc; Tinto, Halidou; Rosanas-Urgell, Anna

    2017-01-01

    Congenital malaria diagnosis is challenging due to frequently observed low parasite density infections, while their clinical relevance during early infancy is not well characterized. In Nanoro health district (Burkina Faso), we determined the prevalence of congenital malaria by real-time

  18. Comparison of two matrix-assisted laser desorption ionisation-time of flight mass spectrometry methods for the identification of clinically relevant anaerobic bacteria

    NARCIS (Netherlands)

    Veloo, A. C. M.; Knoester, M.; Degener, J. E.; Kuijper, E. J.

    2011-01-01

    Two commercially available MALDI-TOF MS systems, Bruker MS and Shimadzu MS, were compared for the identification of clinically relevant anaerobic bacteria. A selection of 79 clinical isolates, representing 19 different genera, were tested and compared with identification obtained by 16S rRNA gene

  19. Trapping of Syntaxin1a in Presynaptic Nanoclusters by a Clinically Relevant General Anesthetic

    Directory of Open Access Journals (Sweden)

    Adekunle T. Bademosi

    2018-01-01

    Full Text Available Summary: Propofol is the most commonly used general anesthetic in humans. Our understanding of its mechanism of action has focused on its capacity to potentiate inhibitory systems in the brain. However, it is unknown whether other neural mechanisms are involved in general anesthesia. Here, we demonstrate that the synaptic release machinery is also a target. Using single-particle tracking photoactivation localization microscopy, we show that clinically relevant concentrations of propofol and etomidate restrict syntaxin1A mobility on the plasma membrane, whereas non-anesthetic analogs produce the opposite effect and increase syntaxin1A mobility. Removing the interaction with the t-SNARE partner SNAP-25 abolishes propofol-induced syntaxin1A confinement, indicating that syntaxin1A and SNAP-25 together form an emergent drug target. Impaired syntaxin1A mobility and exocytosis under propofol are both rescued by co-expressing a truncated syntaxin1A construct that interacts with SNAP-25. Our results suggest that propofol interferes with a step in SNARE complex formation, resulting in non-functional syntaxin1A nanoclusters. : Bademosi et al. use single-molecule imaging microscopy to understand how general anesthetics might affect presynaptic release mechanisms. They find that a clinically relevant concentration of propofol targets the presynaptic release machinery by specifically restricting syntaxin1A mobility on the plasma membrane. This suggests an alternate target process for these drugs. Keywords: super-resolution microscopy, sptPALM, propofol, etomidate, SNARE, Drosophila melanogaster, PC12, syntaxin1A, SNAP-25, neurotransmission

  20. Clinical relevance of the ROC and free-response paradigms for comparing imaging system efficacies

    International Nuclear Information System (INIS)

    Chakraborty, D. P.

    2010-01-01

    Observer performance studies are widely used to assess medical imaging systems. Unlike technical/engineering measurements observer performance include the entire imaging chain and the radiologist. However, the widely used receiver operating characteristic (ROC) method ignores lesion localisation information. The free-response ROC (FROC) method uses the location information to appropriately reward or penalise correct or incorrect localizations, respectively. This paper describes a method for improving the clinical relevance of FROC studies. The method consists of assigning appropriate risk values to the different lesions that may be present on a single image. A high-risk lesion is one that is critical to detect and act upon, and is assigned a higher risk value than a low-risk lesion, one that is relatively innocuous. Instead of simply counting the number of lesions that are detected, as is done in conventional FROC analysis, a risk-weighted count is used. This has the advantage of rewarding detections of high-risk lesions commensurately more than detections of lower risk lesions. Simulations were used to demonstrate that the new method, termed case-based analysis, results in a higher figure of merit for an expert who detects more high-risk lesions than a naive observer who detects more low-risk lesions, even though both detect the same total number of lesions. Conventional free-response analysis is unable to distinguish between the two types of observers. This paper also comments on the issue of clinical relevance of ROC analysis vs. FROC for tasks that involve lesion localisation. (authors)

  1. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  2. 17DD yellow fever vaccine: a double blind, randomized clinical trial of immunogenicity and safety on a dose-response study.

    Science.gov (United States)

    Martins, Reinaldo M; Maia, Maria de Lourdes S; Farias, Roberto Henrique G; Camacho, Luiz Antonio B; Freire, Marcos S; Galler, Ricardo; Yamamura, Anna Maya Yoshida; Almeida, Luiz Fernando C; Lima, Sheila Maria B; Nogueira, Rita Maria R; Sá, Gloria Regina S; Hokama, Darcy A; de Carvalho, Ricardo; Freire, Ricardo Aguiar V; Pereira Filho, Edson; Leal, Maria da Luz Fernandes; Homma, Akira

    2013-04-01

    To verify if the Bio-Manguinhos 17DD yellow fever vaccine (17DD-YFV) used in lower doses is as immunogenic and safe as the current formulation. Doses from 27,476 IU to 587 IU induced similar seroconversion rates and neutralizing antibodies geometric mean titers (GMTs). Immunity of those who seroconverted to YF was maintained for 10 mo. Reactogenicity was low for all groups. Young and healthy adult males (n = 900) were recruited and randomized into 6 groups, to receive de-escalating doses of 17DD-YFV, from 27,476 IU to 31 IU. Blood samples were collected before vaccination (for neutralization tests to yellow fever, serology for dengue and clinical chemistry), 3 to 7 d after vaccination (for viremia and clinical chemistry) and 30 d after vaccination (for new yellow fever serology and clinical chemistry). Adverse events diaries were filled out by volunteers during 10 d after vaccination. Volunteers were retested for yellow fever and dengue antibodies 10 mo later. Seropositivity for dengue was found in 87.6% of volunteers before vaccination, but this had no significant influence on conclusions. In young healthy adults Bio-Manguinhos/Fiocruz yellow fever vaccine can be used in much lower doses than usual. INTERNATIONAL REGISTER: ISRCTN 38082350.

  3. Estimation Of Effective Dose In Ingestion Of Food Crops For 137Cs

    International Nuclear Information System (INIS)

    Angeleska, A.; Dimitrieska-Stojkovic, E.; Uzunov, R.; Hajrulai-Musliu, Z.; Stojanovska-Dimzoska, B.; Jankuloski, D.; Crceva-Nikolovska, R.

    2015-01-01

    The interaction of the ionizing radiation with the human body leads to various biological effects which afterwards can be manifested as clinical symptoms. The nature and the seriousness of the symptoms depend on the absorbed dose, as well as the dose rate, and many diseases which were supposed to be effectively managed if information for the radiation level of an environment was available. The knowledge of the concentration of radioactivity of our environment is of essential relevance in the assessment of the dose that is accumulated in the population, as well as for the formation of the basis for estimation of the level of radioactive contamination or contamination in the environment in future. Taking into consideration the relevance of the distribution and the transfer of radionuclides from the soil to the crops, this work was aimed to estimate the effective dose in ingestion of separate crops for 137Cs. The effective dose was determined by means of already known transfer factors from the soil to the plants and measured concentrations of activities of soil from specific locations in the surrounding of the city of Skopje. The agricultural crops used for analysis are the most commonly applied crops (vegetables, legumes, root crops) in Republic of Macedonia. The radiometric analysis of these samples was conducted by applying a spectrometer for gamma-rays with Germanium with high purity (HPGe). The estimated effective dose would apply for adults who ingested the mentioned crops which were produced at the mentioned locations, that is, in the region of Skopje. These data can be the basis for estimation of risk for radioactive contamination of the population, received by ingestion of produced food. (author).

  4. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  5. Interpretation of proton relative biological effectiveness using lesion induction, lesion repair, and cellular dose distribution

    International Nuclear Information System (INIS)

    Paganetti, H.

    2005-01-01

    Phenomenological biophysical models have been successfully used to estimate the relative biological effectiveness (RBE) of ions. The predictive power of these models is limited because they require measured dose-response data that are not necessarily available for all clinically relevant end points. Furthermore, input parameters often lack mechanistic interpretation. In order to link RBE to more fundamental biological parameters we combine the concepts of two well-established biophysical models, i.e., the phenomenological 'track structure' model and the more mechanistic 'lethal lesion/potentially lethal lesion' (LPL) model. We parametrize a relation between RBE, dose homogeneity in the cell nucleus and induction rates for different lesion types. The macroscopic dose-response relationship is described in the LPL model and the microscopic, subcellular, relationship is determined by the local dose deposition pattern. The formalism provides a framework for a mechanistic interpretation of RBE values

  6. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  7. First branchial cleft anomaly: clinical insight into its relevance in otolaryngology with pediatric considerations.

    Science.gov (United States)

    Maithani, Tripti; Pandey, Apporva; Dey, Debraj; Bhardwaj, Aparna; Singh, V P

    2014-01-01

    First branchial cleft anomalies (FBCA) represent a small subset of congenital malformations in neck. Prime objective of this study is to share our experience with FBCA, emphasize its relevance in otolaryngology and deal with its pediatric perspective. Embryology, pathologic anatomy and varied spectra of clinical presentations of FBCA are discussed. Along with this we have illustrated three different cases; all of them were of pediatric age group and were misdiagnosed by their treating specialists elsewhere. In this article we have also laid special emphasis on its pediatric considerations. FBCA are mostly misdiagnosed due to their unfamiliar clinical signs and symptoms. Swellings may masquerade as other neck masses. Majority of patients give a history of previous incision and drainage. While dealing with pediatric patients the important factors to be kept in mind are the age of child, superficial course of facial nerve, any associated agenesis of parotid gland. Alteration in surgical technique may be required in children. A thorough medical examination with high index of clinical suspicion should be kept in mind while dealing with such anomalies. Owing to their complex presentation and close relation with facial nerve they are challenging lesions for surgeons.

  8. Clinical relevance of retrieval cues for attenuating context renewal of fear.

    Science.gov (United States)

    Culver, Najwa C; Stoyanova, Milena; Craske, Michelle G

    2011-03-01

    The present studies investigated if retrieval cues (reminder objects) can attenuate context renewal of fear. In Study 1, 32 participants completed exposure in one of two contexts; 1-week follow-up testing occurred in a novel or the same context. Results indicated significant renewal of fear for those tested in a novel context. In Study 2, 40 participants completed exposure in one of these contexts; half were presented with cues. One week later, all were tested in a novel context with or without cues. Results indicated weak attenuation of context renewal for participants re-presented with cues. In Study 3, 18 participants completed exposure in one of two maximally distinct contexts; all with cues. One week later, participants were tested in a novel context with or without cues. Results indicated no group differences. These findings suggest that clinical relevance of this set of cues for attenuating context renewal may be limited. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Ocular pharmacokinetics and tolerability of bimatoprost ophthalmic solutions administered once or twice daily in rabbits, and clinical dosing implications

    Directory of Open Access Journals (Sweden)

    Shen J

    2017-09-01

    Full Text Available Jie Shen,1 Margot L Goodkin,2 Warren Tong,2 Mayssa Attar3 1Clinical Pharmacology, 2Clinical Development, 3Clinical Pharmacology, Metabolism and Immunology, Allergan plc, Irvine, CA, USA Purpose: Fixed-combination medications can benefit patients requiring multiple agents to lower their intraocular pressure (IOP, but combining agents with complementary mechanisms of action is challenging if their dosing frequency differs. This study compares in vivo pharmacokinetic and ocular tolerability of bimatoprost 0.01% ophthalmic solutions dosed once or twice daily. Reports of twice-daily dosing in glaucoma patients are also reviewed.Methods: New Zealand White rabbits were administered bimatoprost 0.01% monotherapy or fixed-combination bimatoprost 0.01%/brimonidine 0.1%, once or twice daily in both eyes for 4 days. Ocular tissues were harvested and analyzed by liquid chromatography-tandem mass spectrometry. The pharmacokinetic parameters calculated included maximum observed concentration, time to maximum concentration, and area under the concentration-time curve.Results: Due to extensive metabolism, bimatoprost concentration was below the quantitation limit by 1 hour post-dose in all samples. Bimatoprost acid exposure, however, could be measured up to 6–8 hours post-dose and was similar in the aqueous humor and iris-ciliary body (pharmacological site of action of animals treated once or twice daily with either bimatoprost 0.01% or fixed-combination bimatoprost 0.01%/brimonidine 0.1%. Increasing dosage frequency in rabbits did not raise the incidence of drug-related conjunctival hyperemia (most common adverse event associated with bimatoprost use in humans, suggesting comparable ocular tolerability of the once- and twice-daily regimens for each formulation.Conclusion: Bimatoprost 0.01% administered once or twice daily as monotherapy and in fixed-combination with brimonidine 0.1% in rabbits show similar pharmacokinetic profiles of bimatoprost acid

  10. Classification of perimenstrual headache: clinical relevance.

    Science.gov (United States)

    MacGregor, E Anne

    2012-10-01

    Although more than 50% of women with migraine report an association between migraine and menstruation, menstruation has generally considered to be no more than one of a variety of different migraine triggers. In 2004, the second edition of the International Classification of Headache Disorders introduced specific diagnostic criteria for menstrual migraine. Results from research undertaken subsequently lend support to the clinical impression that menstrual migraine should be seen as a distinct clinical entity. This paper reviews the recent research and provides specific recommendations for consideration in future editions of the classification.

  11. The Netherlands XTC Toxicity (NeXT) study: objectives and methods of a study investigating causality, course, and clinical relevance

    NARCIS (Netherlands)

    de Win, Maartje M. L.; Jager, Gerry; Vervaeke, Hylke K. E.; Schilt, Thelma; Reneman, Liesbeth; Booij, Jan; Verhulst, Frank C.; den Heeten, Gerard J.; Ramsey, Nick F.; Korf, Dirk J.; van den Brink, Wim

    2005-01-01

    This paper describes the objectives and methods of The Netherlands XTC Toxicity (NeXT) study focussing on the causality, course, and clinical relevance of ecstasy neurotoxicity. Previous studies suggest that ecstasy (3,4 methylene-dioxymethamphetamine, MDMA, XTC) is toxic toward brain serotonin

  12. Boron neutron capture therapy using mixed epithermal and thermal neutron beams in patients with malignant glioma-correlation between radiation dose and radiation injury and clinical outcome

    International Nuclear Information System (INIS)

    Kageji, Teruyoshi; Nagahiro, Shinji; Matsuzaki, Kazuhito; Mizobuchi, Yoshifumi; Toi, Hiroyuki; Nakagawa, Yoshinobu; Kumada, Hiroaki

    2006-01-01

    Purpose: To clarify the correlation between the radiation dose and clinical outcome of sodium borocaptate-based intraoperative boron neutron capture therapy in patients with malignant glioma. Methods and Materials: The first protocol (P1998, n = 8) prescribed a maximal gross tumor volume (GTV) dose of 15 Gy. In 2001, a dose-escalated protocol was introduced (P2001, n 11), which prescribed a maximal vascular volume dose of 15 Gy or, alternatively, a clinical target volume (CTV) dose of 18 Gy. Results: The GTV and CTV doses in P2001 were 1.1-1.3 times greater than those in P1998. The maximal vascular volume dose of those with acute radiation injury was 15.8 Gy. The mean GTV and CTV dose in long-term survivors with glioblastoma was 26.4 and 16.5 Gy, respectively. A statistically significant correlation between the GTV dose and median survival time was found. In the 11 glioblastoma patients in P2001, the median survival time was 19.5 months and 1- and 2-year survival rate was 60.6% and 37.9%, respectively. Conclusion: Dose escalation contributed to the improvement in clinical outcome. To avoid radiation injury, the maximal vascular volume dose should be <12 Gy. For long-term survival in patients with glioblastoma after boron neutron capture therapy, the optimal mean dose of the GTV and CTV was 26 and 16 Gy, respectively

  13. Effectiveness of one dose of mumps vaccine against clinically diagnosed mumps in Guangzhou, China, 2006-2012.

    Science.gov (United States)

    Fu, Chuanxi; Xu, Jianxiong; Cai, Yuanjun; He, Qing; Zhang, Chunhuan; Chen, Jian; Dong, Zhiqiang; Hu, Wensui; Wang, Hui; Zhu, Wei; Wang, Ming

    2013-12-01

    Although mumps-containing vaccines were introduced in China in 1990s, mumps continues to be a public health concern due to the lack of decline in reported mumps cases. To assess the mumps vaccine effectiveness (VE) in Guangzhou, China, we performed a 1:1 matched case-control study. Among children in Guangzhou aged 8 mo to 12 y during 2006 to 2012, we matched one healthy child to each child with clinically diagnosed mumps. Cases with clinically diagnosed mumps were identified from surveillance sites system and healthy controls were randomly sampled from the Children's Expanded Programmed Immunization Administrative Computerized System in Guangzhou. Conditional logistic regression was used to calculate VE. We analyzed the vaccination information for 1983 mumps case subjects and 1983 matched controls and found that the overall VE for 1 dose of mumps vaccine, irrespective of the manufacture, was 53.6% (95% confidence interval [CI], 41.0-63.5%) to children aged 8 mo to 12 y. This post-marketing mumps VE study found that immunization with one dose of the mumps vaccine confers partial protection against mumps disease. Evaluation of the VE for the current mumps vaccines, introduction of a second dose of mumps vaccine, and assessment of modifications to childhood immunization schedules is essential.

  14. Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams

    Science.gov (United States)

    Moignier, Cyril; Tromson, Dominique; de Marzi, Ludovic; Marsolat, Fanny; García Hernández, Juan Carlos; Agelou, Mathieu; Pomorski, Michal; Woo, Romuald; Bourbotte, Jean-Michel; Moignau, Fabien; Lazaro, Delphine; Mazal, Alejandro

    2017-07-01

    The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min-1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate

  15. SU-E-T-183: Clinical Quality Assurance Workflow for Dynamic Tumor Tracking Radiation Dose Delivery

    International Nuclear Information System (INIS)

    Mamalui-Hunter, M; Su, Z; Li, Z

    2015-01-01

    Purpose: One of the most important aspects of implementation of new treatment modalities is an ‘end-to-end’ verification of the treatment process. Radiation treatment based on dynamic tracking of a tumor is highly patient-specific, therefore, special attention should be paid to quality assurance of the treatment delivery. Our goal was to design the clinical workflow that ensures accurate delivery of the planned dose using the Dynamic Target Tracking option of VeroTM (BrainLab,MHI) linac. Methods: A patient simulation is designed to include a pre-treatment session to verify whether the system can reliably track the motion of the implanted marker and build the 4D model of the target motion. The external surrogate and target motion patterns are recorded in the ExactracTM log files. In this work, a spectrum of custom marker and external surrogate motion trajectories closely resembling the patient specific motion patterns was used. 1mm thick/11mm long VisicoilTM marker was placed 15 and 20mm from the center of the spherical tissue equivalent target (centroid to centroid distance) in the 4D motion phantom (CIRSTM). 3D conformal (3 mm block margin) SBRT plans were delivered to 2 moving targets in the phantom: 1) 20mm diameter target that allows ion chamber dose measurement and 2) 25mm target that allows using film to measure CAX dose (GafchromicTM EBT3 used). The measured dose was compared to the iPlanTM TPS results using MonteCarlo algorithm (1% variance, Dose-to-water). Results: On average, film shows 98.9% pass using gamma criterion for 2% and 2mm DTA, 94.3% match for 2% and 1 mm DTA, 98% pass for 1% and 2 mm DTA however only 88% points passing for 1% and 1 mm DTA. Ion chamber measurements agreed with the calculation within 1.5%. Conclusion: The clinical QA workflow was designed for SBRT delivery using real-time tumor tracking on VeroTM linac

  16. Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Johnson, Thorsten R.C.; Sommer, Wieland H.; Thierfelder, Kolja M.; Meinel, Felix G. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-06-01

    To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDI{sub vol}, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. (orig.)

  17. Pharmacokinetic/Pharmacodynamic Modelling of Receptor Internalization with CRTH2 Antagonists to Optimize Dose Selection.

    Science.gov (United States)

    Krause, Andreas; Zisowsky, Jochen; Strasser, Daniel S; Gehin, Martine; Sidharta, Patricia N; Groenen, Peter M A; Dingemanse, Jasper

    2016-07-01

    The chemoattractant receptor-homologous molecule expressed on T helper-2 cells (CRTH2) is a G-protein-coupled receptor for prostaglandin D2 (PGD2), a key mediator in inflammatory disorders. Two selective and potent CRTH2 antagonists currently in clinical development, ACT-453859 and setipiprant, were compared with respect to their (predicted) clinical efficacy. Population pharmacokinetic (PK) and pharmacodynamic (PD) models were developed to characterize how plasma concentrations (PK) of ACT-453859, its active metabolite ACT-463036 and setipiprant related to their effect on blocking PGD2-induced internalization of CRTH2 on eosinophils (PD). Simulations were used to identify doses and dosing regimens leading to 90 % of maximum blockade of CRTH2 internalization at trough. A combined concentration of ACT-453859 and its metabolite ACT-463036, with weights proportional to potency (based on an eosinophil shape change assay), enabled good characterization of the PD effect. The modelling and simulation results facilitated decision making by suggesting an ACT-453859 dose of 400 mg once daily (or 100 mg twice daily) for clinically relevant CRTH2 antagonism. Pharmacometric quantification demonstrated that CRTH2 internalization is a useful new biomarker to study CRTH2 antagonism. Ninety percent of maximum blockade of CRTH2 internalization at trough is suggested as a quantitative PD target in clinical studies.

  18. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    Science.gov (United States)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  19. Reduction of uterus dose in clinical thoracic computed tomography

    International Nuclear Information System (INIS)

    Danova, D.; Keil, B.; Kaestner, B.; Klose, K.J.; Heverhagen, J.T.; Wulff, J.; Fiebich, M.; Zink, K.

    2010-01-01

    Purpose: The aim of this study was to investigate the potential dose reduction in the uterus as a result of lead apron protection during thoracic CT scans. Moreover, the distribution of the radiation dose in the uterus was determined in order to obtain information about the ratio of internally and externally scattered radiation. Materials and Methods: The uterus doses during thoracic CT were determined by measuring organ doses using an Alderson-RANDO registered -Phantom and thermoluminescent dosimeters. A 0.25 mm lead equivalent protective apron was used to shield the abdominal area. Three measurement conditions were evaluated: without lead apron, covered with lead apron and wrapped with lead apron. The uterus dose with and without shielding describes the mean value and standard deviation of all examinations and all measurement points in the organ. Results: The uterus dose by thoracic CT was measured to be approximately 66.5 ± 3.1 μGy. If the abdomen is covered with a 0.25 mm Pb equivalent lead apron in the front area and on both sides, the uterus dose is reduced to 49.4 ± 2.8 μGy (26 % reduction, p < 0.001). If a lead apron is wrapped around the abdomen, providing 0.50 mm Pb shielding in the anterior section due to overlap, and 0.25 mm Pb in the posterior section and on both sides, the uterus dose is reduced even more to 43.8 ± 2.5 μGy (34 % reduction, p < 0.001). The dose distribution when the lead apron covers the abdomen shows that the shielding is effective for the scatter radiation that comes from the anterior part. Moreover, the wrapped apron protects the uterus from all directions and is even more effective for dose reduction than the covering apron. Conclusion: Our findings demonstrate that protective aprons are an effective dose reduction technique without additional costs and little effect on patient examination time. (orig.)

  20. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer

    Science.gov (United States)

    González, S. J.; Pozzi, E. C. C.; Monti Hughes, A.; Provenzano, L.; Koivunoro, H.; Carando, D. G.; Thorp, S. I.; Casal, M. R.; Bortolussi, S.; Trivillin, V. A.; Garabalino, M. A.; Curotto, P.; Heber, E. M.; Santa Cruz, G. A.; Kankaanranta, L.; Joensuu, H.; Schwint, A. E.

    2017-10-01

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson’s correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  1. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer.

    Science.gov (United States)

    González, S J; Pozzi, E C C; Monti Hughes, A; Provenzano, L; Koivunoro, H; Carando, D G; Thorp, S I; Casal, M R; Bortolussi, S; Trivillin, V A; Garabalino, M A; Curotto, P; Heber, E M; Santa Cruz, G A; Kankaanranta, L; Joensuu, H; Schwint, A E

    2017-10-03

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  2. Clinical and Neurobiological Relevance of Current Animal Models of Autism Spectrum Disorders

    Science.gov (United States)

    Kim, Ki Chan; Gonzales, Edson Luck; Lázaro, María T.; Choi, Chang Soon; Bahn, Geon Ho; Yoo, Hee Jeong; Shin, Chan Young

    2016-01-01

    Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by social and communication impairments, as well as repetitive and restrictive behaviors. The phenotypic heterogeneity of ASD has made it overwhelmingly difficult to determine the exact etiology and pathophysiology underlying the core symptoms, which are often accompanied by comorbidities such as hyperactivity, seizures, and sensorimotor abnormalities. To our benefit, the advent of animal models has allowed us to assess and test diverse risk factors of ASD, both genetic and environmental, and measure their contribution to the manifestation of autistic symptoms. At a broader scale, rodent models have helped consolidate molecular pathways and unify the neurophysiological mechanisms underlying each one of the various etiologies. This approach will potentially enable the stratification of ASD into clinical, molecular, and neurophenotypic subgroups, further proving their translational utility. It is henceforth paramount to establish a common ground of mechanistic theories from complementing results in preclinical research. In this review, we cluster the ASD animal models into lesion and genetic models and further classify them based on the corresponding environmental, epigenetic and genetic factors. Finally, we summarize the symptoms and neuropathological highlights for each model and make critical comparisons that elucidate their clinical and neurobiological relevance. PMID:27133257

  3. Sterol Composition of Clinically Relevant Mucorales and Changes Resulting from Posaconazole Treatment.

    Science.gov (United States)

    Müller, Christoph; Neugebauer, Thomas; Zill, Patrizia; Lass-Flörl, Cornelia; Bracher, Franz; Binder, Ulrike

    2018-05-19

    Mucorales are fungi with increasing importance in the clinics. Infections take a rapidly progressive course resulting in high mortality rates. The ergosterol biosynthesis pathway and sterol composition are of interest, since they are targeted by currently applied antifungal drugs. Nevertheless, Mucorales often exhibit resistance to these drugs, resulting in therapeutic failure. Here, sterol patterns of six clinically relevant Mucorales ( Lichtheimia corymbifera , Lichtheimia ramosa , Mucor circinelloides , Rhizomucor pusillus , Rhizopus arrhizus , and Rhizopus microsporus ) were analysed in a targeted metabolomics fashion after derivatization by gas chromatography-mass spectrometry. Additionally, the effect of posaconazole (POS) treatment on the sterol pattern of R. arrhizus was evaluated. Overall, fifteen different sterols were detected with species dependent variations in the total and relative sterol amount. Sterol analysis from R. arrhizus hyphae confronted with sublethal concentrations of posaconazole revealed the accumulation of 14-methylergosta-8,24-diene-3,6-diol, which is a toxic sterol that was previously only detected in yeasts. Sterol content and composition were further compared to the well-characterized pathogenic mold Aspergillus fumigatus . This work contributes to a better understanding of the ergosterol biosynthesis pathway of Mucorales, which is essential to improve antifungal efficacy, the identification of targets for novel drug design, and to investigate the combinatorial effects of drugs targeting this pathway.

  4. Psychometric properties and clinical relevance of the adolescent sleep hygiene scale in Dutch adolescents.

    Science.gov (United States)

    de Bruin, Eduard J; van Kampen, Ris K A; van Kooten, Tamar; Meijer, Anne Marie

    2014-07-01

    This study investigated reliability, validity, and clinical relevance of the Adolescent Sleep Hygiene Scale (ASHS) in Dutch adolescents. The Dutch translation of the ASHS was administered to 186 normal-sleeping adolescents and 112 adolescents with insomnia. Their sleep variables were measured using sleep logs and questionnaires. From the insomnia group, scores were also obtained after six weeks of cognitive behavioral therapy for insomnia (n=58) or waiting list (n=22). The full scale of the ASHS had acceptable internal consistency. The results showed moderate to strong correlations of the ASHS (domains) with sleep quality, sleep duration and chronic sleep reduction. Furthermore, the Dutch ASHS was able to discriminate between normal sleepers and adolescents with insomnia, and scores of adolescents with insomnia improved after treatment. These findings confirm the importance of sleep hygiene in adolescent sleep, and contribute to the validity of the ASHS and its applicability in research and clinical practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  6. Radiation-induced liver disease after stereotactic body radiotherapy for small hepatocellular carcinoma: clinical and dose-volumetric parameters

    International Nuclear Information System (INIS)

    Jung, Jinhong; Choi, Eun Kyung; Kim, Jong Hoon; Yoon, Sang Min; Kim, So Yeon; Cho, Byungchul; Park, Jin-hong; Kim, Su Ssan; Song, Si Yeol; Lee, Sang-wook; Ahn, Seung Do

    2013-01-01

    To investigate the clinical and dose–volumetric parameters that predict the risk of radiation-induced liver disease (RILD) for patients with small, unresectable hepatocellular carcinoma (HCC) treated with stereotactic body radiotherapy (SBRT). Between March 2007 and December 2009, 92 patients with HCC treated with SBRT were reviewed for RILD within 3 months of completing treatment. RILD was evaluated according to the Common Terminology Criteria for Adverse Events, version 3.0. A dose of 10–20 Gy (median, 15 Gy) per fraction was given over 3–4 consecutive days for a total dose of 30–60 Gy (median, 45 Gy). The following clinical and dose–volumetric parameters were examined: age, gender, Child-Pugh class, presence of hepatitis B virus, gross tumor volume, normal liver volume, radiation dose, fraction size, mean dose to the normal liver, and normal liver volumes receiving from < 5 Gy to < 60 Gy (in increments of 5 Gy). Seventeen (18.5%) of the 92 patients developed grade 2 or worse RILD after SBRT (49 patients in grade 1, 11 in grade 2, and 6 in ≥ grade 3). On univariate analysis, Child-Pugh class was identified as a significant clinical parameter, while normal liver volume and normal liver volumes receiving from < 15 Gy to < 60 Gy were the significant dose–volumetric parameters. Upon multivariate analysis, only Child-Pugh class was a significant parameter for predicting grade 2 or worse RILD. The Child-Pugh B cirrhosis was found to have a significantly greater susceptibility to the development of grade 2 or worse RILD after SBRT in patients with small, unresectable HCC. Additional efforts aimed at testing other models to predict the risk of RILD in a large series of HCC patients treated with SBRT are needed

  7. Clinical relevance of sensitization to peanut and lupine

    NARCIS (Netherlands)

    Peeters, K.A.B.M.

    2007-01-01

    This thesis demonstrates that the use of purified allergens and techniques such as NMR spectroscopy has the potential to improve current diagnostic capabilities. It also shows that lupine allergy is fairly common in The Netherlands. Characteristics of lupine allergy such as the eliciting dose and

  8. Brachytherapy Partial Breast Irradiation: Analyzing Effect of Source Configurations on Dose Metrics Relevant to Toxicity

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Devlin, Phillip M.

    2008-01-01

    Purpose: Recently, the use of partial breast irradiation (PBI) for patients with early-stage breast cancer with low-risk factors has increased. The volume of the high-dose regions has been correlated with toxicity in interstitial treatment. Although no such associations have been made in applicator-based experience, new applicators are being developed that use complex noncentered source configurations. This work studied the effect of noncentered source placements on the volume of the high-dose regions around a spherical applicator. Methods and Materials: Many applicator configurations were numerically simulated for a range of inflation radii. For each configuration, a dose homogeneity index was used as a dose metric to measure the volume of the high-dose region. Results: All multisource configurations examined resulted in an increase of the high-dose region compared with a single-center source. The resulting decrease in the prescription dose homogeneity index was more pronounced for sources further from the center of the applicator, and the effect was reduced as the number of dwell locations was increased. Conclusion: The geometries of particular applicators were not considered to achieve a more general result. On the basis of the calculations of this work, it would appear that treatment using noncentered dwell locations will lead to an increase in the volume of the high-dose regions

  9. Motivation factors for suicidal behavior and their clinical relevance in admitted psychiatric patients.

    Directory of Open Access Journals (Sweden)

    Naoki Hayashi

    Full Text Available Suicidal behavior (SB is a major, worldwide health concern. To date there is limited understanding of the associated motivational aspects which accompany this self-initiated conduct.To develop a method for identifying motivational features associated with SB by studying admitted psychiatric patients, and to examine their clinical relevance.By performing a factor analytic study using data obtained from a patient sample exhibiting high suicidality and a variety of SB methods, Motivations for SB Scale (MSBS was constructed to measure the features. Data included assessments of DSM-IV psychiatric and personality disorders, suicide intent, depressive symptomatology, overt aggression, recent life events (RLEs and methods of SB, collated from structured interviews. Association of identified features with clinical variables was examined by correlation analyses and MANCOVA.Factor analyses elicited a 4-factor solution composed of Interpersonal-testing (IT, Interpersonal-change (IC, Self-renunciation (SR and Self-sustenance (SS. These factors were classified according to two distinctions, namely interpersonal vs. intra-personal directedness, and the level of assumed influence by SB or the relationship to prevailing emotions. Analyses revealed meaningful links between patient features and clinical variables. Interpersonal-motivations (IT and IC were associated with overt aggression, low suicidality and RLE discord or conflict, while SR was associated with depression, high suicidality and RLE separation or death. Borderline personality disorder showed association with IC and SS. When self-strangulation was set as a reference SB method, self-cutting and overdose-taking were linked to IT and SS, respectively.The factors extracted in this study largely corresponded to factors from previous studies, implying that they may be useful in a wider clinical context. The association of these features with SB-related factors suggests that they constitute an integral part

  10. Clinical and virological effects of high-dose recombinant interferon-alpha in disseminated AIDS-related Kaposi's sarcoma

    NARCIS (Netherlands)

    de Wit, R.; Schattenkerk, J. K.; Boucher, C. A.; Bakker, P. J.; Veenhof, K. H.; Danner, S. A.

    1988-01-01

    The effectiveness and antiretroviral activities of interferon-alpha in AIDS-related Kaposi's sarcoma was assessed in a non-randomised, phase-II clinical trial. 28 patients were treated with high-dose (27-36 MU) human recombinant interferon-alpha 2a subcutaneously every day for 8 weeks. In patients

  11. Validation of Clinical Testing for Warfarin Sensitivity

    Science.gov (United States)

    Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.

    2009-01-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988

  12. [Medical expert consensus in AH on the clinical use of triple fixed-dose antihypertensive therapy in Spain].

    Science.gov (United States)

    Mazón, P; Galve, E; Gómez, J; Gorostidi, M; Górriz, J L; Mediavilla, J D

    The opinion of experts (different specialties) on the triple fixed-dose antihypertensive therapy in clinical practice may differ. Online questionnaire with controversial aspects of the triple therapy answered by panel of experts in hypertension (HT) using two-round modified Delphi method. The questionnaire was completed by 158 experts: Internal Medicine (49), Nephrology (26), Cardiology (83). Consensus was reached (agreement) on 27/45 items (60%); 7 items showed differences statistically significant. Consensus was reached regarding: Predictive factors in the need for combination therapy and its efficacy vs. increasing the dose of a pretreatment, and advantage of triple therapy (prescription/adherence/cost/pressure control) vs. free combination. This consensus provides an overview of the clinical use of triple therapy in moderate-severe and resistant/difficult to control HT. Copyright © 2016 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Characterisation of lung tumour under dosage for interpretation of clinical trial data

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dunn, L.; Franich, R.D.; Kron, T.; Height, F.

    2010-01-01

    Full text: It is well known that the periphery of lung tumours is under-dosed in radiotherapy as a result of electronic disequilibrium at the interface of lung and tumour tissue. Clinical trials often employ dose calculation algorithms which poorly approximate the dose to peripheral regions of tumour volumes. The aim of this study was to develop a set of systematic under-dosage estimates corresponding to various clinical parameters. High resolution Monte Carlo radiation transport calculations were undertaken for a systematic set of generic lung tumours irradiated with an external photon beam. Varied parameters include beam energy, field size, tumour size and distance to chest wall. Calculations were undertaken using both EGSnrc and GEAI T4. A 'Dose Reduction Factor' is defined which describes the dose to the peripheral 'shell' 01 the tumour, as relevant for multiple-field and arc therapy. For a 6 MV beam, under-dosage is typically between 2 and 5% for the different arrangements investigated, and for a 15 MV beam it is between 5 and 8% (relative to the central dose). Good agreement between EGSnrc and GEANT4 was demonstrated. Comparisons with pencil beam convolution calculations indicate that the treatment planning system does not identify this under-dosage. A systematic set of data has been obtained that characterises the extent of peripheral under-dosage in lung tumours for the retrospective evaluation of clinical trial data. The data presented i: also informative for clinics using less sophisticated planning algorithms, particularly when dose is being prescribed to covering isodoses. (author)

  14. Dose verification for respiratory-gated volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qian Jianguo; Xing Lei; Liu Wu; Luxton, Gary, E-mail: gluxton@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States)

    2011-08-07

    A novel commercial medical linac system (TrueBeam(TM), Varian Medical Systems, Palo Alto, CA) allows respiratory-gated volumetric modulated arc therapy (VMAT), a new modality for treating moving tumors with high precision and improved accuracy by allowing for regular motion associated with a patient's breathing during VMAT delivery. The purpose of this work is to adapt a previously-developed dose reconstruction technique to evaluate the fidelity of VMAT treatment during gated delivery under clinic-relevant periodic motion related to patient breathing. A Varian TrueBeam system was used in this study. VMAT plans were created for three patients with lung or pancreas tumors. Conventional 6 and 15 MV beams with flattening filter and high-dose-rate 10 MV beams with no flattening filter were used in these plans. Each patient plan was delivered to a phantom first without gating and then with gating for three simulated respiratory periods (3, 4.5 and 6 s). Using the adapted log-file-based dose reconstruction procedure supplemented with ion chamber array (Seven29(TM), PTW, Freiburg, Germany) measurements, the delivered dose was used to evaluate the fidelity of gated VMAT delivery. Comparison of Seven29 measurements with and without gating showed good agreement with gamma-index passing rates above 99% for 1%/1 mm dose accuracy/distance-to-agreement criteria. With original plans as reference, gamma-index passing rates were 100% for the reconstituted plans (1%/1 mm criteria) and 93.5-100% for gated Seven29 measurements (3%/3 mm criteria). In the presence of leaf error deliberately introduced into the gated delivery of a pancreas patient plan, both dose reconstruction and Seven29 measurement consistently indicated substantial dosimetric differences from the original plan. In summary, a dose reconstruction procedure was demonstrated for evaluating the accuracy of respiratory-gated VMAT delivery. This technique showed that under clinical operation, the TrueBeam system

  15. A systematic review of methodology applied during preclinical anesthetic neurotoxicity studies: important issues and lessons relevant to the design of future clinical research.

    Science.gov (United States)

    Disma, Nicola; Mondardini, Maria C; Terrando, Niccolò; Absalom, Anthony R; Bilotta, Federico

    2016-01-01

    Preclinical evidence suggests that anesthetic agents harm the developing brain thereby causing long-term neurocognitive impairments. It is not clear if these findings apply to humans, and retrospective epidemiological studies thus far have failed to show definitive evidence that anesthetic agents are harmful to the developing human brain. The aim of this systematic review was to summarize the preclinical studies published over the past decade, with a focus on methodological issues, to facilitate the comparison between different preclinical studies and inform better design of future trials. The literature search identified 941 articles related to the topic of neurotoxicity. As the primary aim of this systematic review was to compare methodologies applied in animal studies to inform future trials, we excluded a priori all articles focused on putative mechanism of neurotoxicity and the neuroprotective agents. Forty-seven preclinical studies were finally included in this review. Methods used in these studies were highly heterogeneous-animals were exposed to anesthetic agents at different developmental stages, in various doses and in various combinations with other drugs, and overall showed diverse toxicity profiles. Physiological monitoring and maintenance of physiological homeostasis was variable and the use of cognitive tests was generally limited to assessment of specific brain areas, with restricted translational relevance to humans. Comparison between studies is thus complicated by this heterogeneous methodology and the relevance of the combined body of literature to humans remains uncertain. Future preclinical studies should use better standardized methodologies to facilitate transferability of findings from preclinical into clinical science. © 2015 John Wiley & Sons Ltd.

  16. Fetal absorbed doses by radiopharmaceutical administration

    International Nuclear Information System (INIS)

    Rojo, Ana M; Gomez Parada, Ines M.; Di Trano, Jose L.

    2000-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author)

  17. Hyperthermic radiosensitization : mode of action and clinical relevance

    NARCIS (Netherlands)

    Kampinga, HH; Dikomey, E

    Purpose: To provide an update on the recent knowledge about the molecular mechanisms of thermal radiosensitization and its possible relevance to thermoradiotherapy. Summary: Hyperthermia is probably the most potent cellular radiosensitizer known to date. Heat interacts with radiation and potentiates

  18. Relation between dose of bendrofluazide, antihypertensive effect, and adverse biochemical effects

    DEFF Research Database (Denmark)

    Carlsen, J E; Køber, L; Torp-Pedersen, C

    1990-01-01

    OBJECTIVE--To determine the relevant dose of bendrofluazide for treating mild to moderate hypertension. DESIGN--Double blind parallel group trial of patients who were given placebo for six weeks and then randomly allocated to various doses of bendrofluazide (1.25, 2.5, 5, or 10 mg daily) or place...... of bendrofluazide to treat mild to moderate hypertension is 1.25-2.5 mg a day. Higher doses caused more pronounced adverse biochemical effects including adverse lipid effects. Previous trials with bendrofluazide have used too high doses....... relations between dose and effect were shown for potassium, urate, glucose, total cholesterol, and apolipoprotein B concentrations. The 1.25 mg dose increased only urate concentrations, whereas the 10 mg dose affected all the above biochemical variables. CONCLUSION--The relevant range of doses...

  19. An assessment of effective dose to staff in external beam radiotherapy

    International Nuclear Information System (INIS)

    Rawlings, D.J.; Nicholson, L.

    1997-01-01

    Radiation safety in external beam radiotherapy is governed by national legislation. Annual doses recorded by radiographers and others associated with external beam radiotherapy are typically much lower than the relevant dose limit. However, it is possible that larger doses might be received as a result of an accidental irradiation. In the event of a significant exposure resulting in a dose at or near a relevant dose limit, an accurate conversion has to be made from the dose meter reading to the limiting quantity. A method was devised to demonstrate ratios of effective dose to personal dose equivalent which might be anticipated in the even of an individual other than the patient being irradiated within a radiotherapy treatment room consisting of a linear accelerator. The variation of ratios obtained under different conditions is discussed. (author)

  20. Dose properties of a laser accelerated electron beam and prospects for clinical application

    International Nuclear Information System (INIS)

    Kainz, K.K.; Hogstrom, K.R.; Antolak, J.A.; Almond, P.R.; Bloch, C.D.; Chiu, C.; Fomytskyi, M.; Raischel, F.; Downer, M.; Tajima, T.

    2004-01-01

    Laser wakefield acceleration (LWFA) technology has evolved to where it should be evaluated for its potential as a future competitor to existing technology that produces electron and x-ray beams. The purpose of the present work is to investigate the dosimetric properties of an electron beam that should be achievable using existing LWFA technology, and to document the necessary improvements to make radiotherapy application for LWFA viable. This paper first qualitatively reviews the fundamental principles of LWFA and describes a potential design for a 30 cm accelerator chamber containing a gas target. Electron beam energy spectra, upon which our dose calculations are based, were obtained from a uniform energy distribution and from two-dimensional particle-in-cell (2D PIC) simulations. The 2D PIC simulation parameters are consistent with those reported by a previous LWFA experiment. According to the 2D PIC simulations, only approximately 0.3% of the LWFA electrons are emitted with an energy greater than 1 MeV. We studied only the high-energy electrons to determine their potential for clinical electron beams of central energy from 9 to 21 MeV. Each electron beam was broadened and flattened by designing a dual scattering foil system to produce a uniform beam (103%>off-axis ratio>95%) over a 25x25 cm2 field. An energy window (ΔE) ranging from 0.5 to 6.5 MeV was selected to study central-axis depth dose, beam flatness, and dose rate. Dose was calculated in water at a 100 cm source-to-surface distance using the EGS/BEAM Monte Carlo algorithm. Calculations showed that the beam flatness was fairly insensitive to ΔE. However, since the falloff of the depth-dose curve (R 10 -R 90 ) and the dose rate both increase with ΔE, a tradeoff between minimizing (R 10 -R 90 ) and maximizing dose rate is implied. If ΔE is constrained so that R 10 -R 90 is within 0.5 cm of its value for a monoenergetic beam, the maximum practical dose rate based on 2D PIC is approximately 0.1 Gy min-1

  1. Specific activities and the relevant gamma ray dose rates at 1 meter from radioisotopes and isomers following thermal neutron capture reaction

    International Nuclear Information System (INIS)

    Eissa, E.A.; Aly, R.A.; Gomaa, M.A.; Hassan, A.M.

    1995-01-01

    Calculations were performed for the specific activity of 245 gamma-ray emitting radioisotopes and isomers produced in 48, 72 and 96 hour irradiation periods of the natural isotopic mixture of their 77 elements with thermal neutron flux 1.0 E + 13 n/cm 2 .5, at the core of the (ET-R R-1) reactor. The relevant gamma-ray dose rate at a point 1 meter apart from each radioisotope or isomer was evaluated whenever the specific gamma-ray dose rate constant is available. The irradiation time factor (ITF) for the irradiation periods 24, 48, 72 and 96 hours are reported for each of the 248 gamma-ray emitters. The average of (ITF) over these 248 radionuclides for each irradiation period is taken as a measure of the feasibility of the irradiation time. The results favour the increase of the irradiation period from the conventional 48 to 72 hours but not to 96 hours. A programme was established in the VAX computer to carry out the above mentioned calculations. Tables of the present work are very useful for isotope production and reactor safety. 1 fig., 2 tabs

  2. Dose indices: everybody wants a number

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2014-01-01

    This paper discusses the merits and weaknesses of the standard terms that have been developed to quantify CT dose: CT dose indices (CTDI), dose length product (DLP) and effective dose. The difference between the measured CTDI vol and the CTDI vol displayed on the CT scanner illustrates a clinical dilemma. Displayed CTDI vol represents the radiation dose delivered to a plastic phantom, which is significantly different from the dose delivered to the patient, depending on the size of the patient. Although effective dose is simple to calculate for an individual patient, it was never intended for this purpose. The need for a simple, appropriate method to estimate pediatric patient doses led to the development of the size-specific dose estimate (SSDE), the newest CT dose index. Here I compare SSDE and its merits to the use of effective dose to estimate patient dose. The discussion concludes with a few sample calculations and basic clinical applications of SSDE to better quantify pediatric patient dose from CT scans. (orig.)

  3. Lithium formate EPR dosimetry for verifications of planned dose distributions prior to intensity-modulated radiation therapy

    Science.gov (United States)

    Gustafsson, H.; Lund, E.; Olsson, S.

    2008-09-01

    The objective of the present investigation was to evaluate lithium formate electron paramagnetic resonance (EPR) dosimetry for measurement of dose distributions in phantoms prior to intensity-modulated radiation therapy (IMRT). Lithium formate monohydrate tablets were carefully prepared, and blind tests were performed in clinically relevant situations in order to determine the precision and accuracy of the method. Further experiments confirmed that within the accuracy of the current method, the dosimeter response was independent of beam energies and dose rates used for IMRT treatments. The method was applied to IMRT treatment plans, and the dose determinations were compared to ionization chamber measurements. The experiments showed that absorbed doses above 3 Gy could be measured with an uncertainty of less than 2.5% of the dose (coverage factor k = 1.96). Measurement time was about 15 min using a well-calibrated dosimeter batch. The conclusion drawn from the investigation was that lithium formate EPR dosimetry is a promising new tool for absorbed dose measurements in external beam radiation therapy, especially for doses above 3 Gy.

  4. Lithium formate EPR dosimetry for verifications of planned dose distributions prior to intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, H; Lund, E [Department of Medical and Health Sciences, Radiation Physics, Faculty of Health Sciences, Linkoeping University, S-581 85 Linkoeping (Sweden); Olsson, S [Division of Radiation Physics, Linkoeping University Hospital, S-581 85 Linkoeping (Sweden)], E-mail: hakgu@imv.liu.se

    2008-09-07

    The objective of the present investigation was to evaluate lithium formate electron paramagnetic resonance (EPR) dosimetry for measurement of dose distributions in phantoms prior to intensity-modulated radiation therapy (IMRT). Lithium formate monohydrate tablets were carefully prepared, and blind tests were performed in clinically relevant situations in order to determine the precision and accuracy of the method. Further experiments confirmed that within the accuracy of the current method, the dosimeter response was independent of beam energies and dose rates used for IMRT treatments. The method was applied to IMRT treatment plans, and the dose determinations were compared to ionization chamber measurements. The experiments showed that absorbed doses above 3 Gy could be measured with an uncertainty of less than 2.5% of the dose (coverage factor k = 1.96). Measurement time was about 15 min using a well-calibrated dosimeter batch. The conclusion drawn from the investigation was that lithium formate EPR dosimetry is a promising new tool for absorbed dose measurements in external beam radiation therapy, especially for doses above 3 Gy.

  5. Abundances of Clinically Relevant Antibiotic Resistance Genes and Bacterial Community Diversity in the Weihe River, China

    Directory of Open Access Journals (Sweden)

    Xiaojuan Wang

    2018-04-01

    Full Text Available The spread of antibiotic resistance genes in river systems is an emerging environmental issue due to their potential threat to aquatic ecosystems and public health. In this study, we used droplet digital polymerase chain reaction (ddPCR to evaluate pollution with clinically relevant antibiotic resistance genes (ARGs at 13 monitoring sites along the main stream of the Weihe River in China. Six clinically relevant ARGs and a class I integron-integrase (intI1 gene were analyzed using ddPCR, and the bacterial community was evaluated based on the bacterial 16S rRNA V3–V4 regions using MiSeq sequencing. The results indicated Proteobacteria, Actinobacteria, Cyanobacteria, and Bacteroidetes as the dominant phyla in the water samples from the Weihe River. Higher abundances of blaTEM, strB, aadA, and intI1 genes (103 to 105 copies/mL were detected in the surface water samples compared with the relatively low abundances of strA, mecA, and vanA genes (0–1.94 copies/mL. Eight bacterial genera were identified as possible hosts of the intI1 gene and three ARGs (strA, strB, and aadA based on network analysis. The results suggested that the bacterial community structure and horizontal gene transfer were associated with the variations in ARGs.

  6. Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans

    International Nuclear Information System (INIS)

    Kroon, Petra S; Hol, Sandra; Essers, Marion

    2013-01-01

    The main aim of the current study was to assess the dosimetric accuracy and clinical quality of volumetric modulated arc therapy (VMAT) plans for stereotactic (stage I) and conventional (stage III) lung cancer treatments planned with Eclipse version 10.0 Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithm. The dosimetric impact of using AAA instead of AXB, and grid size 2.5 mm instead of 1.0 mm for VMAT treatment plans was evaluated. The clinical plan quality of AXB VMAT was assessed using 45 stage I and 73 stage III patients, and was compared with published results, planned with VMAT and hybrid-VMAT techniques. The dosimetric impact on near-minimum PTV dose (D 98% ) using AAA instead of AXB was large (underdose up to 12.3%) for stage I and very small (underdose up to 0.8%) for stage III lung treatments. There were no significant differences for dose volume histogram (DVH) values between grid sizes. The calculation time was significantly higher for AXB grid size 1.0 than 2.5 mm (p < 0.01). The clinical quality of the VMAT plans was at least comparable with clinical qualities given in literature of lung treatment plans with VMAT and hybrid-VMAT techniques. The average mean lung dose (MLD), lung V 20Gy and V 5Gy in this study were respectively 3.6 Gy, 4.1% and 15.7% for 45 stage I patients and 12.4 Gy, 19.3% and 46.6% for 73 stage III lung patients. The average contra-lateral lung dose V 5Gy-cont was 35.6% for stage III patients. For stereotactic and conventional lung treatments, VMAT calculated with AXB grid size 2.5 mm resulted in accurate dose calculations. No hybrid technique was needed to obtain the dose constraints. AXB is recommended instead of AAA for avoiding serious overestimation of the minimum target doses compared to the actual delivered dose

  7. Optimizing clopidogrel dose response: a new clinical algorithm comprising CYP2C19 pharmacogenetics and drug interactions

    Directory of Open Access Journals (Sweden)

    Saab YB

    2015-09-01

    Full Text Available Yolande B Saab,1 Rony Zeenny,2 Wijdan H Ramadan2 1School of Pharmacy, Pharmaceutical Sciences Department, 2School of Pharmacy, Pharmacy Practice Department, Lebanese American University, Byblos, Lebanon Purpose: Response to clopidogrel varies widely with nonresponse rates ranging from 4% to 30%. A reduced function of the gene variant of the CYP2C19 has been associated with lower drug metabolite levels, and hence diminished platelet inhibition. Drugs that alter CYP2C19 activity may also mimic genetic variants. The aim of the study is to investigate the cumulative effect of CYP2C19 gene polymorphisms and drug interactions that affects clopidogrel dosing, and apply it into a new clinical-pharmacogenetic algorithm that can be used by clinicians in optimizing clopidogrel-based treatment. Method: Clopidogrel dose optimization was analyzed based on two main parameters that affect clopidogrel metabolite area under the curve: different CYP2C19 genotypes and concomitant drug intake. Clopidogrel adjusted dose was computed based on area under the curve ratios for different CYP2C19 genotypes when a drug interacting with CYP2C19 is added to clopidogrel treatment. A clinical-pharmacogenetic algorithm was developed based on whether clopidogrel shows 1 expected effect as per indication, 2 little or no effect, or 3 clinical features that patients experience and fit with clopidogrel adverse drug reactions. Results: The study results show that all patients under clopidogrel treatment, whose genotypes are different from *1*1, and concomitantly taking other drugs metabolized by CYP2C19 require clopidogrel dose adjustment. To get a therapeutic effect and avoid adverse drug reactions, therapeutic dose of 75 mg clopidogrel, for example, should be lowered to 6 mg or increased to 215 mg in patients with different genotypes. Conclusion: The implementation of clopidogrel new algorithm has the potential to maximize the benefit of clopidogrel pharmacological therapy

  8. Clinically evident fat necrosis in women treated with high-dose-rate brachytherapy alone for early-stage breast cancer

    International Nuclear Information System (INIS)

    Wazer, David E.; Lowther, David; Boyle, Teresa; Ulin, Kenneth; Neuschatz, Andrew; Ruthazer, Robin; DiPetrillo, Thomas A.

    2001-01-01

    Purpose: To investigate the incidence of and variables associated with clinically evident fat necrosis in women treated on a protocol of high-dose-rate (HDR) brachytherapy alone without external-beam whole-breast irradiation for early-stage breast carcinoma. Methods and Materials: From 6/1997 until 8/1999, 30 women diagnosed with Stage I or II breast carcinoma underwent surgical excision and postoperative irradiation via HDR brachytherapy implant as part of a multi-institutional clinical Phase I/II protocol. Patients eligible included those with T1, T2, N0, N1 (≤3 nodes positive), M0 tumors of nonlobular histology with negative surgical margins, no extracapsular lymph-node extension, and a negative postexcision mammogram. Brachytherapy catheters were placed at the initial excision, re-excision, or at the time of axillary sampling. Direct visualization, surgical clips, ultrasound, or CT scans assisted in delineating the target volume defined as the excision cavity plus 2-cm margin. High activity 192 Ir (3-10 Ci) was used to deliver 340 cGy per fraction, 2 fractions per day, for 5 consecutive days to a total dose of 34 Gy to the target volume. Source position and dwell times were calculated using standard volume optimization techniques. Dosimetric analyses were performed with three-dimensional postimplant dose and volume reconstructions. The median follow-up of all patients was 24 months (range, 12-36 months). Results: Eight patients (crude incidence of 27%) developed clinically evident fat necrosis postimplant in the treated breast. Fat necrosis was determined by clinical presentation including pain and swelling in the treated volume, computed tomography, and/or biopsy. All symptomatic patients (7 of 8 cases) were successfully treated with 3 to 12 months of conservative management. Continuous variables that were found to be associated significantly with fat necrosis included the number of source dwell positions (p=0.04), and the volume of tissue which received

  9. The dose effects of short-term dronabinol (oral THC) maintenance in daily cannabis users.

    Science.gov (United States)

    Vandrey, Ryan; Stitzer, Maxine L; Mintzer, Miriam Z; Huestis, Marilyn A; Murray, Jeannie A; Lee, Dayong

    2013-02-01

    Prior studies have separately examined the effects of dronabinol (oral THC) on cannabis withdrawal, cognitive performance, and the acute effects of smoked cannabis. A single study examining these clinically relevant domains would benefit the continued evaluation of dronabinol as a potential medication for the treatment of cannabis use disorders. Thirteen daily cannabis smokers completed a within-subject crossover study and received 0, 30, 60 and 120mg dronabinol per day for 5 consecutive days. Vital signs and subjective ratings of cannabis withdrawal, craving and sleep were obtained daily; outcomes under active dose conditions were compared to those obtained under placebo dosing. On the 5th day of medication maintenance, participants completed a comprehensive cognitive performance battery and then smoked five puffs of cannabis for subjective effects evaluation. Each dronabinol maintenance period occurred in a counterbalanced order and was separated by 9 days of ad libitum cannabis use. Dronabinol dose-dependently attenuated cannabis withdrawal and resulted in few adverse side effects or decrements in cognitive performance. Surprisingly, dronabinol did not alter the subjective effects of smoked cannabis, but cannabis-induced increases in heart rate were attenuated by the 60 and 120mg doses. Dronabinol's ability to dose-dependently suppress cannabis withdrawal may be therapeutically beneficial to individuals trying to stop cannabis use. The absence of gross cognitive impairment or side effects in this study supports safety of doses up to 120mg/day. Continued evaluation of dronabinol in targeted clinical studies of cannabis treatment, using an expanded range of doses, is warranted. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Improvement of the clinical use of computed radiography for mobile chest imaging: Image quality and patient dose

    Science.gov (United States)

    Rill, Lynn Neitzey

    Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for

  11. Association between SLC19A1 gene polymorphism and high dose methotrexate toxicity in childhood acute lymphoblastic leukaemia and non Hodgkin malignant lymphoma: introducing a haplotype based approach

    Directory of Open Access Journals (Sweden)

    Kotnik Barbara Faganel

    2017-09-01

    Full Text Available We investigated the clinical relevance of SLC 19A1 genetic variability for high dose methotrexate (HD-MTX related toxicities in children and adolescents with acute lymphoblastic leukaemia (ALL and non Hodgkin malignant lymphoma (NHML.

  12. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  13. Volume dose ratios relevant for alanine dosimetry in small, 6 MV photon beams

    DEFF Research Database (Denmark)

    Cronholm, Rickard O.; Andersen, Claus Erik; Behrens, Claus F.

    2012-01-01

    therapy). To this end, we here present the results of a Monte Carlo simulation study with DOSRZnrc that investigated the influence of field and detector size for small 6 MV photon beams. The study focusses on doses averaged over the volume of the detector rather than point doses.The ratio of volume...... averaged doses to water (D¯W) and alanine (D¯det) was found to be approximately 1.025 for most situations studied, and a constant ratio is likely to be representative for many applications in radiation therapy. However, D¯W/D¯det was found to be as low as 0.9908 ± 0.0037 in situations where one might...... expect significant deviations from charged particle equilibrium (i.e. at shallow depths and when the field size was smaller than the range of the secondary electrons). These effects therefore need consideration when finite-size alanine dosimeters are used under such conditions....

  14. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  15. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP).

    Science.gov (United States)

    Ngwa, Wilfred; Korideck, Houari; Chin, Lee M; Makrigiorgos, G Mike; Berbeco, Ross I

    2011-12-01

    The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.

  16. Nonclinical safety of mavrilimumab, an anti-GMCSF receptor alpha monoclonal antibody, in cynomolgus monkeys: Relevance for human safety

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Patricia C., E-mail: ryanp@medimmune.com [MedImmune, LLC, Gaithersburg, MD (United States); Sleeman, Matthew A. [MedImmune, LLC, Cambridge (United Kingdom); Rebelatto, Marlon [MedImmune, LLC, Gaithersburg, MD (United States); Wang, Bing; Lu, Hong [MedImmune, LLC, Moutain View, CA (United States); Chen, Xiaomin [Novartis, East Hanover, NJ (United States); Wu, Chi-Yuan [MedImmune, LLC, Moutain View, CA (United States); Hinrichs, Mary Jane; Roskos, Lorin [MedImmune, LLC, Gaithersburg, MD (United States); Towers, Heidi [MedImmune, LLC, Cambridge (United Kingdom); McKeever, Kathleen; Dixit, Rakesh [MedImmune, LLC, Gaithersburg, MD (United States)

    2014-09-01

    Mavrilimumab (CAM-3001) is an investigational human IgG4 monoclonal antibody (MAb) targeting GM-CSF receptor alpha which is currently being developed for the treatment of RA. GM-CSF plays a central role in the pathogenesis of rheumatoid arthritis (RA) through the activation, differentiation, and survival of macrophages and neutrophils. To support clinical development, the nonclinical safety of mavrilimumab was evaluated in several studies with cynomolgus monkeys as the pharmacologically relevant species. Comprehensive toxicity parameters were assessed in each study, and treatment duration ranged from 4 to 26 weeks. Mavrilimumab has an acceptable safety profile in monkeys with no changes in any parameters other than microscopic findings in lung. In several studies, minimal accumulation of foamy alveolar macrophages was observed. This finding was only seen in studies of at least 11 weeks duration, was reversible following a dose-free recovery period and was considered non-adverse. At higher dose levels (≥ 30 mg/kg/week), in a 26-week repeat-IV dose study, the presence of lung foreign material, cholesterol clefts, and granulomatous inflammation was also observed in a few animals and was considered adverse. The dose- and time-related accumulation of foamy macrophages in lung following exposure to mavrilimumab observed in several NHP studies was expected based upon the known role of GM-CSFRα signaling in the function of alveolar macrophages. Overall, a clean no-observed-adverse-effect-level (NOAEL) without any effects in lung was established and provided adequate clinical safety margins. In clinical studies in RA patients, mavrilimumab has demonstrated good clinical activity with adequate safety to support further clinical development. A Phase 2b study of mavrilimumab in subjects with RA is in progress. - Highlights: • Mavrilimumab is a MAB targeting GM-CSFRα being developed for RA therapy. • Mavrilimumab has an acceptable safety profile in cynomolgus monkeys.

  17. Nonclinical safety of mavrilimumab, an anti-GMCSF receptor alpha monoclonal antibody, in cynomolgus monkeys: Relevance for human safety

    International Nuclear Information System (INIS)

    Ryan, Patricia C.; Sleeman, Matthew A.; Rebelatto, Marlon; Wang, Bing; Lu, Hong; Chen, Xiaomin; Wu, Chi-Yuan; Hinrichs, Mary Jane; Roskos, Lorin; Towers, Heidi; McKeever, Kathleen; Dixit, Rakesh

    2014-01-01

    Mavrilimumab (CAM-3001) is an investigational human IgG4 monoclonal antibody (MAb) targeting GM-CSF receptor alpha which is currently being developed for the treatment of RA. GM-CSF plays a central role in the pathogenesis of rheumatoid arthritis (RA) through the activation, differentiation, and survival of macrophages and neutrophils. To support clinical development, the nonclinical safety of mavrilimumab was evaluated in several studies with cynomolgus monkeys as the pharmacologically relevant species. Comprehensive toxicity parameters were assessed in each study, and treatment duration ranged from 4 to 26 weeks. Mavrilimumab has an acceptable safety profile in monkeys with no changes in any parameters other than microscopic findings in lung. In several studies, minimal accumulation of foamy alveolar macrophages was observed. This finding was only seen in studies of at least 11 weeks duration, was reversible following a dose-free recovery period and was considered non-adverse. At higher dose levels (≥ 30 mg/kg/week), in a 26-week repeat-IV dose study, the presence of lung foreign material, cholesterol clefts, and granulomatous inflammation was also observed in a few animals and was considered adverse. The dose- and time-related accumulation of foamy macrophages in lung following exposure to mavrilimumab observed in several NHP studies was expected based upon the known role of GM-CSFRα signaling in the function of alveolar macrophages. Overall, a clean no-observed-adverse-effect-level (NOAEL) without any effects in lung was established and provided adequate clinical safety margins. In clinical studies in RA patients, mavrilimumab has demonstrated good clinical activity with adequate safety to support further clinical development. A Phase 2b study of mavrilimumab in subjects with RA is in progress. - Highlights: • Mavrilimumab is a MAB targeting GM-CSFRα being developed for RA therapy. • Mavrilimumab has an acceptable safety profile in cynomolgus monkeys.

  18. Optimization of the dose level for a given treatment plan to maximize the complication-free tumor cure

    International Nuclear Information System (INIS)

    Lind, B.K.; Mavroidis, P.; Hyoedynmaa, S.; Kappas, C.

    1999-01-01

    During the past decade, tumor and normal tissue reactions after radiotherapy have been increasingly quantified in radiobiological terms. For this purpose, response models describing the dependence of tumor and normal tissue reactions on the irradiated volume, heterogeneity of the delivered dose distribution and cell sensitivity variations can be taken into account. The probability of achieving a good treatment outcome can be increased by using an objective function such as P + , the probability of complication-free tumor control. A new procedure is presented, which quantifies P + from the dose delivery on 2D surfaces and 3D volumes and helps the user of any treatment planning system (TPS) to select the best beam orientations, the best beam modalities and the most suitable beam energies. The final step of selecting the prescribed dose level is made by a renormalization of the entire dose plan until the value of P + is maximized. The index P + makes use of clinically established dose-response parameters, for tumors and normal tissues of interest, in order to improve its clinical relevance. The results, using P + , are compared against the assessments of experienced medical physicists and radiation oncologists for two clinical cases. It is observed that when the absorbed dose level for a given treatment plan is increased, the treatment outcome first improves rapidly. As the dose approaches the tolerance of normal tissues the complication-free curve begins to drop. The optimal dose level is often just below this point and it depends on the geometry of each patient and target volume. Furthermore, a more conformal dose delivery to the target results in a higher control rate for the same complication level. This effect can be quantified by the increased value of the P + parameter. (orig.)

  19. Clinical relevance of positive voltage-gated potassium channel (VGKC)-complex antibodies: experience from a tertiary referral centre.

    Science.gov (United States)

    Paterson, Ross W; Zandi, Michael S; Armstrong, Richard; Vincent, Angela; Schott, Jonathan M

    2014-06-01

    Voltage-gated potassium channel (VGKC)-complex antibodies can be associated with a range of immunotherapy-responsive clinical presentations including limbic encephalitis, Morvan's syndrome and acquired neuromyotonia. However, there are patients with positive levels in whom the significance is uncertain. To evaluate the clinical significance associated with positive (>100 pM) VGKC-complex antibodies. Over a 4-year period, 1053 samples were sent for testing of which 55 were positive. The clinical presentations, final diagnoses and responses to immunotherapies, when given, were assessed retrospectively and the likelihood of autoimmunity was categorised as definite, possible, unlikely or undetermined (modified from Zuliani et al 2012). Only 4 of the 32 patients with low-positive (100-400 pM) levels were considered definitely autoimmune, 3 with peripheral nerve hyperexcitability and 1 with a thymoma; 3 were given immunotherapies. Of the remaining 28 with low-positive levels, 13 (3 of whom had tumours) were considered possibly autoimmune, and 15 were unlikely or undetermined; 1 was given immunotherapy unsuccessfully. Of the 23 patients with high-positive (>400 pM) levels, 12 were given immunotherapies, 11 of whom showed a good response. 11 were considered definitely autoimmune, 10 with limbic encephalitis (antibody specificity: 5 LGI1, 1 contactin2, 2 negative, 2 untested) and 1 with a tumour. In the remaining 12, autoimmunity was considered possible (n=9; most had not received immunotherapies), or unlikely (n=3). As antibody testing becomes more widely available, and many samples are referred from patients with less clear-cut diagnoses, it is important to assess the utility of the results. VGKC-complex antibodies in the range of 100-400 pM (0.1-0.4 nM) were considered clinically relevant in rare conditions with peripheral nerve hyperexcitability and appeared to associate with tumours (12.5%). By contrast high-positive (>400 pM; >0.4 nM) levels were considered definitely

  20. Selecting relevant and feasible measurement instruments for the revised Dutch clinical practice guideline for physical therapy in patients after stroke

    NARCIS (Netherlands)

    Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert

    2017-01-01

    Purpose: To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. Methods: In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability