WorldWideScience

Sample records for clinical specimens obtained

  1. Microbiology specimens obtained at the time of surgical lung biopsy for interstitial lung disease: clinical yield and cost analysis.

    Science.gov (United States)

    Fibla, Juan J; Brunelli, Alessandro; Allen, Mark S; Wigle, Dennis; Shen, Robert; Nichols, Francis; Deschamps, Claude; Cassivi, Stephen D

    2012-01-01

    In efforts to obtain complete results, current practice in surgical lung biopsy (LB) for interstitial lung disease (ILD) recommends sending lung tissue samples for bacterial, mycobacterial, fungal, and viral cultures. This study assesses the value of this practice by evaluating the microbiology findings obtained from LB for ILD and their associated costs. A total of 296 consecutive patients (140 women, 156 men, median age=61 years) underwent LB for ILD from 2002 to 2009. All had lung tissue sent for microbiology examination. Microbiology results and resultant changes in patient management were analyzed retrospectively. A cost analysis was performed based upon nominal hospital charges adjusted on current inflation rates. Cost data included cultures, stains, smears, direct fluorescent antibody studies, and microbiologist consulting fees. As many as 25 patients (8.4%) underwent open LB and 271 (91.6%) underwent thoracoscopic LB. A total of 592 specimens were assessed (range 1-4 per patient). The most common pathologic diagnoses were idiopathic pulmonary fibrosis in 122 (41.2%), cryptogenic organizing pneumonia in 31 (10.5%), and respiratory bronchiolitis ILD in 16 (5.4%). Microbiology testing was negative in 174 patients (58.8%). A total of 118 of 122 (96.7%) positive results were clinically considered to be contaminants and resulted in no change in clinical management. The most common contaminants were Propionibacterium acnes (38 patients; 31%) and Penicillium fungus (16 patients; 13%). In only four patients (1.4%), the organism cultured (Nocardia one, Histoplasma one, and Aspergillus fumigatus two) resulted in a change in clinical management. The cost of microbiology studies per specimen was $984 (€709), with a total cost for the study cohort being $582,000 (€420,000). The yield and impact on clinical management of microbiology specimens from LB for ILD is very low. Its routine use in LB is questionable. We suggest it should be limited to those cases of ILD with

  2. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  3. "Salvage microbiology": detection of bacteria directly from clinical specimens following initiation of antimicrobial treatment.

    Directory of Open Access Journals (Sweden)

    John J Farrell

    Full Text Available PCR coupled with electrospray ionization mass spectrometry (ESI-MS is a diagnostic approach that has demonstrated the capacity to detect pathogenic organisms from culture negative clinical samples after antibiotic treatment has been initiated. [1] We describe the application of PCR/ESI-MS for detection of bacteria in original patient specimens that were obtained after administration of antibiotic treatment in an open investigation analysis.We prospectively identified cases of suspected bacterial infection in which cultures were not obtained until after the initiation of antimicrobial treatment. PCR/ESI-MS was performed on 76 clinical specimens that were submitted for conventional microbiology testing from 47 patients receiving antimicrobial treatment.In our series, 72% (55/76 of cultures obtained following initiation of antimicrobial treatment were non-diagnostic (45 negative cultures; and 10 respiratory specimens with normal flora (5, yeast (4, or coagulase-negative staphylococcus (1. PCR/ESR-MS detected organisms in 83% (39/47 of cases and 76% (58/76 of the specimens. Bacterial pathogens were detected by PCR/ESI-MS in 60% (27/45 of the specimens in which cultures were negative. Notably, in two cases of relapse of prosthetic knee infections in patients on chronic suppressive antibiotics, the previous organism was not recovered in tissue cultures taken during extraction of the infected knee prostheses, but was detected by PCR/ESI-MS.Molecular methods that rely on nucleic acid amplification may offer a unique advantage in the detection of pathogens collected after initiation of antimicrobial treatment and may provide an opportunity to target antimicrobial therapy and "salvage" both individual treatment regimens as well as, in select cases, institutional antimicrobial stewardship efforts.

  4. Clinical relevance of DNA microarray analyses using archival formalin-fixed paraffin-embedded breast cancer specimens

    International Nuclear Information System (INIS)

    Sadi, Al Muktafi; Wang, Dong-Yu; Youngson, Bruce J; Miller, Naomi; Boerner, Scott; Done, Susan J; Leong, Wey L

    2011-01-01

    The ability of gene profiling to predict treatment response and prognosis in breast cancers has been demonstrated in many studies using DNA microarray analyses on RNA from fresh frozen tumor specimens. In certain clinical and research situations, performing such analyses on archival formalin fixed paraffin-embedded (FFPE) surgical specimens would be advantageous as large libraries of such specimens with long-term follow-up data are widely available. However, FFPE tissue processing can cause fragmentation and chemical modifications of the RNA. A number of recent technical advances have been reported to overcome these issues. Our current study evaluates whether or not the technology is ready for clinical applications. A modified RNA extraction method and a recent DNA microarray technique, cDNA-mediated annealing, selection, extension and ligation (DASL, Illumina Inc) were evaluated. The gene profiles generated from FFPE specimens were compared to those obtained from paired fresh fine needle aspiration biopsies (FNAB) of 25 breast cancers of different clinical subtypes (based on ER and Her2/neu status). Selected RNA levels were validated using RT-qPCR, and two public databases were used to demonstrate the prognostic significance of the gene profiles generated from FFPE specimens. Compared to FNAB, RNA isolated from FFPE samples was relatively more degraded, nonetheless, over 80% of the RNA samples were deemed suitable for subsequent DASL assay. Despite a higher noise level, a set of genes from FFPE specimens correlated very well with the gene profiles obtained from FNAB, and could differentiate breast cancer subtypes. Expression levels of these genes were validated using RT-qPCR. Finally, for the first time we correlated gene expression profiles from FFPE samples to survival using two independent microarray databases. Specifically, over-expression of ANLN and KIF2C, and under-expression of MAPT strongly correlated with poor outcomes in breast cancer patients. We

  5. Pretreatment of clinical specimens with sodium dodecyl (lauryl) sulfate is not suitable for the mycobacteria growth indicator tube cultivation method.

    OpenAIRE

    Pfyffer, G E; Welscher, H M; Kissling, P

    1997-01-01

    When using the Mycobacteria Growth Indicator Tube (MGIT), pretreatment of clinical specimens with N-acetyl-L-cysteine-NaOH is recommended by the manufacturer. Processing of clinical specimens (n = 1,000) with sodium dodecyl (lauryl) sulfate-NaOH resulted in both poor recovery and delayed mean time to detection of acid-fast bacilli. Values were comparable to those obtained on solid media.

  6. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  7. Sequence Capture and Phylogenetic Utility of Genomic Ultraconserved Elements Obtained from Pinned Insect Specimens.

    Directory of Open Access Journals (Sweden)

    Bonnie B Blaimer

    Full Text Available Obtaining sequence data from historical museum specimens has been a growing research interest, invigorated by next-generation sequencing methods that allow inputs of highly degraded DNA. We applied a target enrichment and next-generation sequencing protocol to generate ultraconserved elements (UCEs from 51 large carpenter bee specimens (genus Xylocopa, representing 25 species with specimen ages ranging from 2-121 years. We measured the correlation between specimen age and DNA yield (pre- and post-library preparation DNA concentration and several UCE sequence capture statistics (raw read count, UCE reads on target, UCE mean contig length and UCE locus count with linear regression models. We performed piecewise regression to test for specific breakpoints in the relationship of specimen age and DNA yield and sequence capture variables. Additionally, we compared UCE data from newer and older specimens of the same species and reconstructed their phylogeny in order to confirm the validity of our data. We recovered 6-972 UCE loci from samples with pre-library DNA concentrations ranging from 0.06-9.8 ng/μL. All investigated DNA yield and sequence capture variables were significantly but only moderately negatively correlated with specimen age. Specimens of age 20 years or less had significantly higher pre- and post-library concentrations, UCE contig lengths, and locus counts compared to specimens older than 20 years. We found breakpoints in our data indicating a decrease of the initial detrimental effect of specimen age on pre- and post-library DNA concentration and UCE contig length starting around 21-39 years after preservation. Our phylogenetic results confirmed the integrity of our data, giving preliminary insights into relationships within Xylocopa. We consider the effect of additional factors not measured in this study on our age-related sequence capture results, such as DNA fragmentation and preservation method, and discuss the promise of the UCE

  8. Detection of bovine viral diarrhoea virus in specimens from cattle in South Africa and possible association with clinical disease

    Directory of Open Access Journals (Sweden)

    N. Kabongo

    2004-06-01

    Full Text Available Studies covering all aspects of bovine viral diarrhoea virus (BVDV have been conducted in several countries in Europe, Asia and America. In southern Africa, more information is required about the nature of BVDV infection, the prevalence of different strains and the economic importance of the disease. The presence of BVDV in southern Africa has been known since the early 1970s through serological surveys but few reports confirming its presence by virus isolation and correlation with clinical disease are available. Specimens (n = 312 collected in 1998/99, from live and dead cattle from different farming systems, were obtained from private practitioners, feedlot consultants and abattoirs throughout the country. Specimens (n=37 from African buffaloes (Syncerus caffer in the Kruger National Park were also included. All specimens were processed for virus isolation in cell culture with confirmation by means of immunofluorescent antibody tests and some also by means of an antigen capture ELISA. BVDV was isolated from 15 (4.7 % cattle and were all noncytopathic biotypes. BVDV was not detected in 37 lymph nodes obtained from buffaloes in the Kruger National Park. Of the clinical signs in cattle from which virus were isolated, respiratory signs was the most frequent (10/15, followed by diarrhoea (5/15. Abortion, congenital malformations, haemorrhagic diarrhoea and poor growth were also included as criteria for selection of animals for specimen collection, but no BVD viruses were isolated from cattle manifesting these clinical signs.

  9. 42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.

    Science.gov (United States)

    2010-10-01

    ... and pathology specimens. 414.510 Section 414.510 Public Health CENTERS FOR MEDICARE & MEDICAID... date of service for clinical laboratory and pathology specimens. The date of service for either a clinical laboratory test or the technical component of physician pathology service is as follows: (a...

  10. Sample handling of clinical specimens for ultratrace element analysis

    International Nuclear Information System (INIS)

    Cornelis, R.

    1987-01-01

    Some simple logistics to an improved sample handling of clinical specimens are presented. This comprises clean room conditions, clean laboratory ware, ultra-pure reagents and good analytical practice. Sample handling procedures for blood, urine, soft tissues and pharmaceuticals are briefly discussed. (author) 26 refs

  11. qPCR-High resolution melt analysis for drug susceptibility testing of Mycobacterium leprae directly from clinical specimens of leprosy patients.

    Science.gov (United States)

    Araujo, Sergio; Goulart, Luiz Ricardo; Truman, Richard W; Goulart, Isabela Maria B; Vissa, Varalakshmi; Li, Wei; Matsuoka, Masanori; Suffys, Philip; Fontes, Amanda B; Rosa, Patricia S; Scollard, David M; Williams, Diana L

    2017-06-01

    Real-Time PCR-High Resolution Melting (qPCR-HRM) analysis has been recently described for rapid drug susceptibility testing (DST) of Mycobacterium leprae. The purpose of the current study was to further evaluate the validity, reliability, and accuracy of this assay for M. leprae DST in clinical specimens. The specificity and sensitivity for determining the presence and susceptibility of M. leprae to dapsone based on the folP1 drug resistance determining region (DRDR), rifampin (rpoB DRDR) and ofloxacin (gyrA DRDR) was evaluated using 211 clinical specimens from leprosy patients, including 156 multibacillary (MB) and 55 paucibacillary (PB) cases. When comparing the results of qPCR-HRM DST and PCR/direct DNA sequencing, 100% concordance was obtained. The effects of in-house phenol/chloroform extraction versus column-based DNA purification protocols, and that of storage and fixation protocols of specimens for qPCR-HRM DST, were also evaluated. qPCR-HRM results for all DRDR gene assays (folP1, rpoB, and gyrA) were obtained from both MB (154/156; 98.7%) and PB (35/55; 63.3%) patients. All PCR negative specimens were from patients with low numbers of bacilli enumerated by an M. leprae-specific qPCR. We observed that frozen and formalin-fixed paraffin embedded (FFPE) tissues or archival Fite's stained slides were suitable for HRM analysis. Among 20 mycobacterial and other skin bacterial species tested, only M. lepromatosis, highly related to M. leprae, generated amplicons in the qPCR-HRM DST assay for folP1 and rpoB DRDR targets. Both DNA purification protocols tested were efficient in recovering DNA suitable for HRM analysis. However, 3% of clinical specimens purified using the phenol/chloroform DNA purification protocol gave false drug resistant data. DNA obtained from freshly frozen (n = 172), formalin-fixed paraffin embedded (FFPE) tissues (n = 36) or archival Fite's stained slides (n = 3) were suitable for qPCR-HRM DST analysis. The HRM-based assay was also able to

  12. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    Science.gov (United States)

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  13. Characterization of specimens obtained by different sampling methods for evaluation of periodontal bacteria.

    Science.gov (United States)

    Okada, Ayako; Sogabe, Kaoru; Takeuchi, Hiroaki; Okamoto, Masaaki; Nomura, Yoshiaki; Hanada, Nobuhiro

    2017-12-27

    Quantitative analysis of periodontal bacteria is considered useful for clinical diagnosis, evaluation and assessment of the risk of periodontal disease. The purpose of this study was to compare the effectiveness of sampling of saliva, supragingival and subgingival plaque for evaluation of periodontal bacteria. From each of 12 subjects, i) subgingival plaque was collected from the deepest pocket using a sterile paper point, ii) stimulated whole saliva was collected after chewing gum, and iii) supragingival plaque was collected using a tooth brush. These samples were sent to the medical examination laboratory for quantitative analysis of the counts of three periodontal bacterial species: Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia. The proportions of these bacteria in subgingival plaque were higher than those in saliva or supragingival plaque, but lower in subgingival plaque than in saliva or supragingival plaque. In several cases, periodontal bacteria were below the levels of detection in subgingival plaque. We concluded that samples taken from subgingival plaque may be more useful for evaluating the proportion of periodontal bacteria in deep pockets than is the case for other samples. Therefore, for evaluation of periodontal bacteria, clinicians should consider the characteristics of the specimens obtained using different sampling methods.

  14. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D'Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam; Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita

    2017-01-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18 F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  15. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D' Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam, E-mail: jacojulio@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita [Centro Tecnológico do Exercito (CETEx), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the {sup 18}F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  16. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  17. Sensitivity patterns of pseudomonas aeruginosa isolates obtained from clinical specimens in peshawar

    International Nuclear Information System (INIS)

    Abbas, S.H.; Khan, M.Z.U.; Naeem, M.

    2015-01-01

    Pseudomonas aeruginosa (P. aeruginosa) is a highly virulent opportunistic pathogen and a leading cause of nosocomial infections.Affected patients are often hospitalized in an intensive care unit, and are immuno-compromised as a result of disease and treatment. Suspected P. aeruginosa require timely, adequate and empirical antibiotic therapy to ensure improved outcomes. The purpose of the study was to find the sensitivity and resistance pattern of P. aeruginosa to various groups of drugs, in clinical isolates collected from two major tertiary care hospitals of Peshawar. Methods: Different clinical isolate were taken from patients admitted in various wards of Khyber Teaching Hospital and Lady Reading Hospital Peshawar. Results: A total of 258 clinical isolates were positive for P. aeruginosa out of 2058 clinical isolates. Pseudomonas showed high degree of resistance to third generation Cephalosporins (Ceftazidime, and Ceftriaxone) and moderate degree of resistance to Quinolones and Aminoglycosides (Ofloxacin, Ciprofloxacin, Levofloxacin and Amikacin). Low resistance was observed to different combinations (Cefoperazone + Sulbactum, Piperacillin + Tazobactum). Meropenem and Imipenem had negligible resistance. Conclusion: There is growing resistance to different classes of antibiotics. Combination drugs are useful approach for empirical treatment in suspected Pseudomonas infection. Imipenem and Meropenem are extremely effective but should be in reserve. (author)

  18. Clinical value of detection of HPL-expressing intermediate trophoblasts in abortion or curettage-obtained specimens for diagnosis of intrauterine or ectopic pregnancies

    International Nuclear Information System (INIS)

    He Xiaomei; Wang Yuping; Wang Lisha; Yang Jingxiu; Gao Xueyan

    2005-01-01

    Objective: To investigate the value of detection of HPL-expressing intermediate trophoblasts in endometrial specimens for diagnosis of intrauterine and ectopic pregnancies. Methods: The examined specimens included: (1) Group I, 35 specimens with suspected intermediate trophoblast in decidua (2) Group II, 30 specimens with decidua-like plump endometrial stroma cells and/ or A-S phenomena in glandular epithelium (3) 30 specimens from proven intrauterine pregnancies serving as controls. Histochemistry (SP method) was used for HPL detection in all these specimens. Results: In the 30 proven intrauterine pregnancies, decidua and villa were present in all the specimens. Only 24 of the 30 were found to be HPL(+) with 6 HPL negatives (20%). In Group I , 28 of the 35 specimens were found to be HPL(+) and all of 28 were from intrauterine pregnancies: Of the 7 HPL negative cases, 5 were later confirmed as with ectopic pregnancy, the remaining 2 were with intrauterine pregnancy. In Group II, 22 of 30 specimens were HPL(+) and all were from intrauterine pregnancy. Of the 8 HPL negative cases, 6 were later confirmed as with ectopic pregnancy and 2 were with intrauterine pregnancy. Combining the data from Group I and II, we could see that in the total 15 HPL negative cases, 11 were with ectopic pregnancy (11/15=73.3%) and 4 were with intrauterine pregnancy (4/15=26.7%). Conclusion: In specimens of intrauterine contents, demonstration of HPL (+) cells could be regarded as confirmative evidence of intrauterine pregnancy. However, the reverse did not hold true. Many of the HPL negative specimens were from intrauterine pregnancies (in this study 4/15 or 26.7%). Therefore, in HPL negative cases, there was a high possibility of ectopic pregnancy but further examinations were required to ascertain the diagnosis. (authors)

  19. Comparison of fastsure tb dna and mgit 960 for the detection of mycobacterium tuberculosis complex in clinical specimens

    International Nuclear Information System (INIS)

    Hussain, A.; Mirza, I.A.; Abbasi, S.A.; Ali, S.; Zia, F.; Ahmed, Z.

    2013-01-01

    Objective: To compare the efficacy of Fastsure TB DNA with fully automated MGIT 960 method for detection of Mycobacterium tuberculosis complex (MTB) in clinical specimens. Study Design: Comparative cross sectional study. Methodology: After decontamination procedure, the clinical specimens were subjected to DNA extraction and amplification. Extracted DNA was separated in a separate tube provided with fastsure TB DNA kit and was then inserted into the cartridge provided and results were observed within 30 minutes. For Processing in MGIT 960, OADC and PANTA were added to the clinical specimens after decontamination and then the tubes were processed in MGIT 960. Results: A total of 80 specimens were tested by both MGIT 960 and fastsure TB DNA. On MGIT 960 system, 57 specimens showed growth of MTB while 23 were negative. On Fastsure TB DNA, 47 Specimens were tested as positive and 33 specimens showed negative result. Sensitivity and specificity of Fastsure TB DNA method was calculated to be 82.45 % and 100 % respectively, while positive and negative predictive values were 100 % and 69.69 % respectively. Conclusion: Fast sure TB DNA is a rapid and accurate method for the detection of Mycobacterium tuberculosis complex (MTB) from clinical specimens. (author)

  20. Next-generation sequencing for molecular diagnosis of lung adenocarcinoma specimens obtained by fine needle aspiration cytology

    Science.gov (United States)

    Qiu, Tian; Guo, Huiqin; Zhao, Huan; Wang, Luhua; Zhang, Zhihui

    2015-06-01

    Identification of multi-gene variations has led to the development of new targeted therapies in lung adenocarcinoma patients, and identification of an appropriate patient population with a reliable screening method is the key to the overall success of tumor targeted therapies. In this study, we used the Ion Torrent next-generation sequencing (NGS) technique to screen for mutations in 89 cases of lung adenocarcinoma metastatic lymph node specimens obtained by fine-needle aspiration cytology (FNAC). Of the 89 specimens, 30 (34%) were found to harbor epidermal growth factor receptor (EGFR) kinase domain mutations. Seven (8%) samples harbored KRAS mutations, and three (3%) samples had BRAF mutations involving exon 11 (G469A) and exon 15 (V600E). Eight (9%) samples harbored PIK3CA mutations. One (1%) sample had a HRAS G12C mutation. Thirty-two (36%) samples (36%) harbored TP53 mutations. Other genes including APC, ATM, MET, PTPN11, GNAS, HRAS, RB1, SMAD4 and STK11 were found each in one case. Our study has demonstrated that NGS using the Ion Torrent technology is a useful tool for gene mutation screening in lung adenocarcinoma metastatic lymph node specimens obtained by FNAC, and may promote the development of new targeted therapies in lung adenocarcinoma patients.

  1. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    Science.gov (United States)

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  2. Quantitative cultures of bronchoscopically obtained specimens should be performed for optimal management of ventilator-associated pneumonia.

    Science.gov (United States)

    Baselski, Vickie; Klutts, J Stacey; Baselski, Vickie; Klutts, J Stacey

    2013-03-01

    Ventilator-associated pneumonia (VAP) is a leading cause of health care-associated infection. It has a high rate of attributed mortality, and this mortality is increased in patients who do not receive appropriate empirical antimicrobial therapy. As a result of the overuse of broad-spectrum antimicrobials such as the carbapenems, strains of Acinetobacter, Enterobacteriaceae, and Pseudomonas aeruginosa susceptible only to polymyxins and tigecycline have emerged as important causes of VAP. The need to accurately diagnose VAP so that appropriate discontinuation or de-escalation of antimicrobial therapy can be initiated to reduce this antimicrobial pressure is essential. Practice guidelines for the diagnosis of VAP advocate the use of bronchoalveolar lavage (BAL) fluid obtained either bronchoscopically or by the use of a catheter passed through the endotracheal tube. The CDC recommends that quantitative cultures be performed on these specimens, using ≥ 10(4) CFU/ml to designate a positive culture (http://www.cdc.gov/nhsn/TOC_PSCManual.html, accessed 30 October 2012). However, there is no consensus in the clinical microbiology community as to whether these specimens should be cultured quantitatively, using the aforementioned designated bacterial cell count to designate infection, or by a semiquantitative approach. We have asked Vickie Baselski, University of Tennessee Health Science Center, who was the lead author on one of the seminal papers on quantitative BAL fluid culture, to explain why she believes that quantitative BAL fluid cultures are the optimal strategy for VAP diagnosis. We have Stacey Klutts, University of Iowa, to advocate the semiquantitative approach.

  3. Recommendations for Collection and Handling of Specimens From Group Breast Cancer Clinical Trials

    Science.gov (United States)

    Leyland-Jones, Brian R.; Ambrosone, Christine B.; Bartlett, John; Ellis, Matthew J.C.; Enos, Rebecca A.; Raji, Adekunle; Pins, Michael R.; Zujewski, Jo Anne; Hewitt, Stephen M.; Forbes, John F.; Abramovitz, Mark; Braga, Sofia; Cardoso, Fatima; Harbeck, Nadia; Denkert, Carsten; Jewell, Scott D.

    2008-01-01

    Recommendations for specimen collection and handling have been developed for adoption across breast cancer clinical trials conducted by the Breast International Group (BIG)-sponsored Groups and the National Cancer Institute (NCI)-sponsored North American Cooperative Groups. These recommendations are meant to promote identifiable standards for specimen collection and handling within and across breast cancer trials, such that the variability in collection/handling practices that currently exists is minimized and specimen condition and quality are enhanced, thereby maximizing results from specimen-based diagnostic testing and research. Three working groups were formed from the Cooperative Group Banking Committee, BIG groups, and North American breast cancer cooperative groups to identify standards for collection and handling of (1) formalin-fixed, paraffin-embedded (FFPE) tissue; (2) blood and its components; and (3) fresh/frozen tissue from breast cancer trials. The working groups collected standard operating procedures from multiple group specimen banks, administered a survey on banking practices to those banks, and engaged in a series of discussions from 2005 to 2007. Their contributions were synthesized into this document, which focuses primarily on collection and handling of specimens to the point of shipment to the central bank, although also offers some guidance to central banks. Major recommendations include submission of an FFPE block, whole blood, and serial serum or plasma from breast cancer clinical trials, and use of one fixative and buffer type (10% neutral phosphate-buffered formalin, pH 7) for FFPE tissue across trials. Recommendations for proper handling and shipping were developed for blood, serum, plasma, FFPE, and fresh/frozen tissue. PMID:18955459

  4. Species identification of Candida isolated from clinical specimens in a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    lsmet Nigar

    2016-07-01

    Full Text Available Background: Candida species are responsible for various clinical manifestations from mucocutaneous overgrowth to blood stream infections especially in immunocompromized situations. Although C. albicans is the most prevalent species, high incidence of non-albicans Candida species with antifungal resistance are emerging which is posing a serious threat to the patients care.Objective: This study aimed to isolate and identify different species of Candida from different clinical specimens. Methods: A total of 100 different clinical specimens were studied of which 35 were oral swab, 28 were high vaginal swab, 15 were urine, 14 were nail, 04 were bronchoalveolar lavage and peritoneal fluid were 04. Among 100 clinical specimens, Candida isolates were identified in 64 specimens. Isolation of Candida species was done by primary culture in SDA. Subsequent identification of species were performed by germ tube test, subculture in chromo­genic agar medium and carbohydrate assimilation test with commonly used twelve sugars.Results: Out of 64 isolated Candida species, Candida albicans were 51.56% and the non-albicans Candida species were 48.44%. The most prevalent Candida species was C. albicans 33 (51.53% followed by C. tropicalis 17 (26.56%. C. glabrata 4 (6.25%, C. parapsilo­sis 4 (6.25%, C. krusei 3 (4.68% and C. guilliermondii 2 (3.2%. One of the isolated Candida species was unidentified.Conclusion: Though Candida albicans was found as the most common species, but non-albicans Candida species are appearing as emerging pathogens as well. Exposure to chemotherapy appeared to be the commonest predisposing factor for Candida infection followed by indwelling urinary catheter in situ for prolong period.

  5. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    International Nuclear Information System (INIS)

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  6. Detection of PCR inhibitors in cervical specimens by using the AMPLICOR Chlamydia trachomatis assay

    NARCIS (Netherlands)

    R.P.A.J. Verkooyen (Roel); A. Luijendijk (Ad); W.M. Huisman; W.H.F. Goessens (Wil); J.A.J.W. Kluytmans (Jan); J.H. van Rijsoort-Vos; H.A. Verbrugh (Henri)

    1996-01-01

    textabstractTo determine that susceptibility of AMPLICOR Chlamydia trachomatis PCR to inhibitory factors possibly present in cervical specimens, we obtained cervical specimens from 200 gynecology patients attending our outpatient clinic. The prevalence of C. trachomatis

  7. Pneumocystis carinii pneumonia in AIDS patients: clinical course in relation to the parasite number found in routine specimens obtained by fiberoptic bronchoscopy

    DEFF Research Database (Denmark)

    Orholm, M; Nielsen, T L; Holten-Andersen, W

    1992-01-01

    The aim of this study was to evaluate whether the amount of Pneumocystis carinii organisms found at fiberoptic bronchoscopy (FB) performed on HIV-positive patients correlated to the character of the P. carinii pneumonia (PCP). A consecutive series of 105 patients presented with 131 episodes...... of pulmonary symptoms requiring FB, and in 75 of these episodes a diagnosis of PCP was made. Specimens were stained with Giemsa and methenamine silver nitrate and the number of parasites found was given as: numerous, many, few or none. The following signs and symptoms were registered: cough, dyspnoea, fever......, loss of weight, chest radiograph, haemoglobin, WBC, CD4 cell count, PO2 and HIV p24 antigen. The PCP was characterized by the clinical course: mild, moderate, severe, and by the outcome: pulmonary healthy, pulmonary insufficiency and death. No correlations between the number of P. carinii organisms...

  8. Analysis of culture-dependent versus culture-independent techniques for identification of bacteria in clinically obtained bronchoalveolar lavage fluid.

    Science.gov (United States)

    Dickson, Robert P; Erb-Downward, John R; Prescott, Hallie C; Martinez, Fernando J; Curtis, Jeffrey L; Lama, Vibha N; Huffnagle, Gary B

    2014-10-01

    The diagnosis and management of pneumonia are limited by the use of culture-based techniques of microbial identification, which may fail to identify unculturable, fastidious, and metabolically active viable but unculturable bacteria. Novel high-throughput culture-independent techniques hold promise but have not been systematically compared to conventional culture. We analyzed 46 clinically obtained bronchoalveolar lavage (BAL) fluid specimens from symptomatic and asymptomatic lung transplant recipients both by culture (using a clinical microbiology laboratory protocol) and by bacterial 16S rRNA gene pyrosequencing. Bacteria were identified in 44 of 46 (95.7%) BAL fluid specimens by culture-independent sequencing, significantly more than the number of specimens in which bacteria were detected (37 of 46, 80.4%, P ≤ 0.05) or "pathogen" species reported (18 of 46, 39.1%, P ≤ 0.0001) via culture. Identification of bacteria by culture was positively associated with culture-independent indices of infection (total bacterial DNA burden and low bacterial community diversity) (P ≤ 0.01). In BAL fluid specimens with no culture growth, the amount of bacterial DNA was greater than that in reagent and rinse controls, and communities were markedly dominated by select Gammaproteobacteria, notably Escherichia species and Pseudomonas fluorescens. Culture growth above the threshold of 10(4) CFU/ml was correlated with increased bacterial DNA burden (P Microbiology. All Rights Reserved.

  9. Practices for Identifying and Rejecting Hemolyzed Specimens Are Highly Variable in Clinical Laboratories.

    Science.gov (United States)

    Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L

    2015-08-01

    Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.

  10. Depletion of Human DNA in Spiked Clinical Specimens for Improvement of Sensitivity of Pathogen Detection by Next-Generation Sequencing

    OpenAIRE

    Hasan, Mohammad R.; Rawat, Arun; Tang, Patrick; Jithesh, Puthen V.; Thomas, Eva; Tan, Rusung; Tilley, Peter

    2016-01-01

    Next-generation sequencing (NGS) technology has shown promise for the detection of human pathogens from clinical samples. However, one of the major obstacles to the use of NGS in diagnostic microbiology is the low ratio of pathogen DNA to human DNA in most clinical specimens. In this study, we aimed to develop a specimen-processing protocol to remove human DNA and enrich specimens for bacterial and viral DNA for shotgun metagenomic sequencing. Cerebrospinal fluid (CSF) and nasopharyngeal aspi...

  11. [Identification of anaerobic gram-negative bacilli isolated from various clinical specimens and determination of antibiotic resistance profiles with E-test methods].

    Science.gov (United States)

    Demir, Cengiz; Keşli, Recep

    2018-01-01

    The aim of this study was to identify gram-negative anaerobic bacilli isolated from various clinical specimens that were obtained from patients with suspected anaerobic infections and to determine the antibiotic resistance profiles by using the antibiotic concentration gradient method. The study was performed in Afyon Kocatepe University Ahmet Necdet Sezer Research and Practice Hospital, Medical Microbiology Laboratory between 1 November 2014 and 30 October 2015. Two hundred and seventyeight clinical specimens accepted for anaerobic culture were enrolled in the study. All the samples were cultivated anaerobically by using Schaedler agar with 5% defibrinated sheep blood and Schaedler broth. The isolated anaerobic gram-negative bacilli were identified by using both the conventional methods and automated identification system (VITEK 2, bioMerieux, France). Antibiotic susceptibility tests were performed with antibiotic concentration gradient method (E-test, bioMerieux, France); against penicillin G, clindamycin, cefoxitin, metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem for each isolate. Of the 28 isolated anaerobic gram-negative bacilli; 14 were identified as Bacteroides fragilis group, 9 were Prevotella spp., and 5 were Fusobacterium spp. The highest resistance rate was found against penicillin (78.5%) and resistance rates against clindamycin and cefoxitin were found as 17.8% and 21.4%, respectively. No resistance was found against metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem. As a result, isolation and identification of anaerobic bacteria are difficult, time-consuming and more expensive when compared with the cost of aerobic culture. The rate of anaerobic bacteria isolation may be increased by obtaining the appropriate clinical specimen and appropriate transportation of these specimens. We believe that the data obtained from the study in our center may offer benefits for the follow up and treatment of infections

  12. Identification of Mycobacterium tuberculosis in Clinical Specimens of Patients Suspected of Having Extrapulmonary Tuberculosis by Application of Nested PCR on Five Different Genes.

    Science.gov (United States)

    Khosravi, Azar D; Alami, Ameneh; Meghdadi, Hossein; Hosseini, Atta A

    2017-01-01

    Definitive and rapid diagnosis of extrapulmonary tuberculosis (EPTB) is challenging since conventional techniques have limitations due to the paucibacillary nature of the disease. To increase the sensitivity of detection of Mycobacterium tuberculosis (MTB) in EPTB specimens, we performed a nested PCR assay targeting several genes of MTB on EPTB specimens. A total of 100 clinical specimens from suspected cases of EPTB were processed. Standard staining for acid fast bacilli (AFB) was performed as the preliminary screening test. Extracted DNAs from specimens were subjected to Nested PCR technique for the detection of five different MTB target genes of IS6110, IS1081, hsp65kd, mbp64 , and mtp40 . On performing AFB staining, only 13% of specimens were positive, of which ascites fluid (33.3%), followed by pleural effusion (30.8%) showed the greatest AFB positivity rate. We demonstrated slight improvement in yields in lymph node which comprised the majority of specimens in this study, by employing PCR targeted to IS6110 - and hsp65-genes in comparison to AFB staining. However, the yields in ascites fluid and pleural effusion were not substantially improved by PCR, but those from bone and wound were, as in nested PCR employing either gene, the same positivity rate were obtained for ascites fluid (33.3%), while for pleural effusion specimens only IS1081 based PCR showed identical positivity rate with AFB stain (30.8%). The results for bone and wound specimens, however, demonstrated an improved yield mainly by employing IS1081 gene. Here, we report higher detection rate of EPTB in clinical specimens using five different targeted MTB genes. This nested PCR approach facilitates the comparison and the selection of the most frequently detected genes. Of course this study demonstrated the priority of IS1081 followed by mtp40 and IS6110 , among the five tested genes and indicates the effectiveness of any of the three genes in the design of an efficient nested-PCR test that

  13. Characterization of Burkholderia rhizoxinica and B. endofungorum isolated from clinical specimens.

    Directory of Open Access Journals (Sweden)

    Jay E Gee

    Full Text Available Eight isolates submitted to CDC from 1989 to 2006 from clinical specimens were initially identified as members of the genus Burkholderia based on preliminary cellular fatty acid analysis and/or 16S rRNA gene sequencing. With the recent descriptions of the new species B. rhizoxinica and B. endofungorum, which are considered endosymbiotic bacteria in Rhizopus microsporus fungi, we now identify seven of these clinical isolates as B. rhizoxinica and one as B. endofungorum based on biochemical testing, 16s rRNA, and DNA-DNA hybridization results. We also further characterize these isolates by assessing toxin production and/or by multiple locus sequence typing.

  14. Prevalence of Nontuberculous Mycobacteria (NTM in Iranian Clinical Specimens: Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Azad Khaledi

    2017-01-01

    Full Text Available Background:    Although, nontuberculous mycobacteria can cause disease in different organisms, they usually are not reported in most countries because scientists in general consider them as non-pathogens. But, increasing nontuberculous mycobacteria diseases occurrence has changed this belief. Nevertheless, there is no meta-analysis review about prevalence of nontuberculous mycobacteria in Iran. Methods:   Any data about prevalence of nontuberculous mycobacteria in clinical specimens in Iran were retrieved by searching data bases such as Pub Med, MEDLINE, and Iranian data bases. Then the meta-analysis was performed by comprehensive meta-analysis software (CMA. Results:    The meta-analysis showed that the prevalence of nontuberculous mycobacteria in the clinical specimens in Iran was 1.3%. In the studies that had sample size less than 300, and in studies conducted after 2004, the prevalence was higher. Also, the prevalence of nontuberculous mycobacteria was higher in the West of Iran. In this study, the most prevalent rapid-growing mycobacterium was Mycobacterium. fortuitum and  most prevalent slow-growing mycobacterium was M. simiae with the prevalence 44.2% and 14.3%, respectively.Conclusion:   M. simiae is the most prevalent nontuberculous mycobacteria in the clinical specimens in Iran. As this species of nontuberculous mycobacteria has similar clinical and radiological manifestations with tuberculosis, it is often treated as tuberculosis. Unfortunately, M. simiae is resistant against first-line anti-TB drugs resulting in treatment failure after using routine anti-TB medication. Therefore, there is an urgent need for application of new diagnostic strategy for identification of nontuberculous mycobacteria species.

  15. Molecular markers: Implications for cytopathology and specimen collection.

    Science.gov (United States)

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  16. Four-hour processing of clinical/diagnostic specimens for electron microscopy using microwave technique.

    Science.gov (United States)

    Giberson, R T; Demaree, R S; Nordhausen, R W

    1997-01-01

    A protocol for routine 4-hour microwave tissue processing of clinical or other samples for electron microscopy was developed. Specimens are processed by using a temperature-restrictive probe that can be set to automatically cycle the magnetron to maintain any designated temperature restriction (temperature maximum). In addition, specimen processing during fixation is performed in 1.7-ml microcentrifuge tubes followed by subsequent processing in flow-through baskets. Quality control is made possible during each step through the addition of an RS232 port to the microwave, allowing direct connection of the microwave oven to any personal computer. The software provided with the temperature probe enables the user to monitor time and temperature on a real-time basis. Tissue specimens, goat placenta, mouse liver, mouse kidney, and deer esophagus were processed by conventional and microwave techniques in this study. In all instances, the results for the microwave-processed samples were equal to or better than those achieved by routine processing techniques.

  17. Isolation of an unidentified pink-pigmented bacterium in a clinical specimen.

    OpenAIRE

    Odugbemi, T; Nwofor, C; Joiner, K T

    1988-01-01

    An unidentified pink-pigmented bacterium isolated from a clinical specimen is reported. The organism was oxidase, urease, and catalase positive; it grew on Thayer-Martin and MacConkey media. The isolate is possibly similar to an unnamed taxon (G.L. Gilardi and Y.C. Faur, J. Clin. Microbiol. 20:626-629, 1984); however, it had unique characteristics of nonmotility with no flagellum detectable and was a gram-negative coccoid with a few rods in pairs and negative for starch hydrolysis.

  18. Isolation of an unidentified pink-pigmented bacterium in a clinical specimen.

    Science.gov (United States)

    Odugbemi, T; Nwofor, C; Joiner, K T

    1988-05-01

    An unidentified pink-pigmented bacterium isolated from a clinical specimen is reported. The organism was oxidase, urease, and catalase positive; it grew on Thayer-Martin and MacConkey media. The isolate is possibly similar to an unnamed taxon (G.L. Gilardi and Y.C. Faur, J. Clin. Microbiol. 20:626-629, 1984); however, it had unique characteristics of nonmotility with no flagellum detectable and was a gram-negative coccoid with a few rods in pairs and negative for starch hydrolysis.

  19. Evaluation and Adaptation of a Laboratory-Based cDNA Library Preparation Protocol for Retrospective Sequencing of Archived MicroRNAs from up to 35-Year-Old Clinical FFPE Specimens.

    Science.gov (United States)

    Loudig, Olivier; Wang, Tao; Ye, Kenny; Lin, Juan; Wang, Yihong; Ramnauth, Andrew; Liu, Christina; Stark, Azadeh; Chitale, Dhananjay; Greenlee, Robert; Multerer, Deborah; Honda, Stacey; Daida, Yihe; Spencer Feigelson, Heather; Glass, Andrew; Couch, Fergus J; Rohan, Thomas; Ben-Dov, Iddo Z

    2017-03-14

    Formalin-fixed paraffin-embedded (FFPE) specimens, when used in conjunction with patient clinical data history, represent an invaluable resource for molecular studies of cancer. Even though nucleic acids extracted from archived FFPE tissues are degraded, their molecular analysis has become possible. In this study, we optimized a laboratory-based next-generation sequencing barcoded cDNA library preparation protocol for analysis of small RNAs recovered from archived FFPE tissues. Using matched fresh and FFPE specimens, we evaluated the robustness and reproducibility of our optimized approach, as well as its applicability to archived clinical specimens stored for up to 35 years. We then evaluated this cDNA library preparation protocol by performing a miRNA expression analysis of archived breast ductal carcinoma in situ (DCIS) specimens, selected for their relation to the risk of subsequent breast cancer development and obtained from six different institutions. Our analyses identified six miRNAs (miR-29a, miR-221, miR-375, miR-184, miR-363, miR-455-5p) differentially expressed between DCIS lesions from women who subsequently developed an invasive breast cancer (cases) and women who did not develop invasive breast cancer within the same time interval (control). Our thorough evaluation and application of this laboratory-based miRNA sequencing analysis indicates that the preparation of small RNA cDNA libraries can reliably be performed on older, archived, clinically-classified specimens.

  20. Identification of non-tuberculous mycobacteria isolated from clinical specimens at a tertiary care hospital: a cross-sectional study.

    Science.gov (United States)

    Ahmed, Imran; Jabeen, Kauser; Hasan, Rumina

    2013-10-22

    Non-tuberculous mycobacteria (NTM) are opportunistic pathogens in immuno-compromised patients. They are also increasingly recognized as pathogens in immuno-competent individuals. Globally, an increase in NTM isolation is being reported with a varied geographic prevalence of different species around the world. There is lack of data on species distribution of these organisms from Pakistan. Treatment options differ according to the species isolated and its susceptibility profile. Knowledge of local species variation would help targeted therapy. This study was performed to determine frequencies of different NTM species isolated from various clinical specimens submitted at a tertiary care hospital laboratory. NTM isolated from 25955 clinical specimens over a period of two years (2010 to 2011) were included. All NTM were identified using conventional tests. Drug susceptibility testing (DST) was performed by broth microdilution and interpreted according to Clinical and Laboratory Standards Institute's document M24-A2. A total of 104 NTM were included in the study. Of these, 76% (54/71) rapidly growing mycobacteria (RGM) and 57.6% (19/33) slow growing mycobacteria (SGM) could be further identified. Mycobacterium fortuitum (21/54) was the commonest NTM identified among RGM followed by M. mucogenicum (12/54) and M. smegmatis (11/54). Among SGM, M. avium complex (MAC) was the most frequent (14/19). Clinical significance could be assessed in a limited number (52/104) of NTM isolates and MAC appeared to be the commonest significant NTM. Three extra-pulmonary cases were found to be healthcare associated infections. DST results for RGM showed susceptibility to amikacin (100%), clarithromycin (100%, except M. fortuitum where it is not reportable), linezolid (90%) and moxifloxacin (75%). Whereas SGM were susceptible to clarithromycin (100%), linezolid (58.8%) and moxifloxacin (64.7%). This is the first study reporting NTM species and their clinical significance isolated from

  1. Comparative performance of PCR-based assay versus microscopy and culture for the direct detection of Mycobacterium tuberculosis in clinical respiratory specimens in Lebanon.

    Science.gov (United States)

    Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W

    2000-09-01

    American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.

  2. Clinical value of IS6110-based loop-mediated isothermal amplification for detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Aryan, Ehsan; Makvandi, Manoochehr; Farajzadeh, Ahmad; Huygen, Kris; Alvandi, Amir-Hooshang; Gouya, Mohammad-Mehdi; Sadrizadeh, Ali; Romano, Marta

    2013-06-01

    A fundamental to global tuberculosis (TB) control is timely and accurate diagnosis of infectious cases of the disease. Among various methods, techniques based on nucleic acid amplification are the ones with promising prospects. The present study evaluates the diagnostic value of the recently developed IS6110-based loop-mediated isothermal amplification (LAMP) for detection of Mycobacterium tuberculosis complex (MTBC) in sputum specimens. In this cross-sectional study (2008-2009), IS6110-LAMP was evaluated on 101 sputum specimens from 93 highly suspected TB patients and compared to Amplicor MTB test and in-house IS6110-PCR and -nested PCR assays. Culture results or clinical recovery following anti-TB therapy was considered as a reference to prove the TB cases. The overall sensitivity of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 89.6% (69/77 specimens; 95% confidence interval [CI], 80.5-95.4%), 76.6% (59/77 specimens; CI, 65.6-85.5%), 79.2% (61/77 specimens; CI, 68.5-87.6%) and 59.7% (46/77 specimens; CI, 47.9-70.8%). The specificity and positive predictive value (PPV) were 100% for all the tests, and the negative predictive value (NPV) of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 75%, 57.1%, 60%, and 43.6%. There was an excellent overall agreement between LAMP and nPCR (k 0.828), and between LAMP and Amplicor (k 0.746), in addition to a better tolerance of IS6110-LAMP to inhibitors present in clinical specimens. The better diagnostic performance of IS6110-LAMP compared to Amplicor (p = 0.009), nPCR (p = 0.013) and PCR (p < 0.0001) besides its rapidity, simplicity, and cost-effectiveness makes it a valuable method for the detection of MTBC in clinical samples, particularly in resource-limited settings. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  3. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  4. SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Fanchon, L; Russell, J; Dogan, S; Carlin, S; Pinker-Domenig, K; Yorke, E; Schmidtlein, C. Ross; Fujisawa, S; Manova-Todorova, K; Zanzonico, P; Deasy, J O; Humm, J L; Solomon, S; Kirov, A S [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based

  5. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  6. Use of CHROMagar Candida for the presumptive identification of Candida species directly from clinical specimens in resource-limited settings

    Science.gov (United States)

    Nadeem, Sayyada Ghufrana; Hakim, Shazia Tabassum; Kazmi, Shahana Urooj

    2010-01-01

    Introduction Identification of yeast isolated from clinical specimens to the species level has become increasingly important. Ever-increasing numbers of immuno-suppressed patients, a widening range of recognized pathogens, and the discovery of resistance to antifungal drugs are contributing factors to this necessity. Material and methods A total of 487 yeast strains were studied for the primary isolation and presumptive identification, directly from clinical specimen. Efficacy of CHROMagar Candida has been evaluated with conventional methods including morphology on Corn meal–tween 80 agar and biochemical methods by using API 20 C AUX. Results The result of this study shows that CHROMagar Candida can easily identify three species of Candida on the basis of colonial color and morphology, and accurately differentiate between them i.e. Candida albicans, Candida tropicalis, and Candida krusei. The specificity and sensitivity of CHROMagar Candida for C. albicans calculated as 99%, for C. tropicalis calculated as 98%, and C. krusei it is 100%. Conclusion The data presented supports the use of CHROMagar Candida for the rapid identification of Candida species directly from clinical specimens in resource-limited settings, which could be very helpful in developing appropriate therapeutic strategy and management of patients. PMID:21483597

  7. Use of CHROMagar Candida for the presumptive identification of Candida species directly from clinical specimens in resource-limited settings

    Directory of Open Access Journals (Sweden)

    Sayyada Ghufrana Nadeem

    2010-02-01

    Full Text Available Introduction: Identification of yeast isolated from clinical specimens to the species level has become increasingly important. Ever-increasing numbers of immuno-suppressed patients, a widening range of recognized pathogens, and the discovery of resistance to antifungal drugs are contributing factors to this necessity. Material and methods: A total of 487 yeast strains were studied for the primary isolation and presumptive identification, directly from clinical specimen. Efficacy of CHROMagar Candida has been evaluated with conventional methods including morphology on Corn meal–tween 80 agar and biochemical methods by using API 20 C AUX. Results: The result of this study shows that CHROMagar Candida can easily identify three species of Candida on the basis of colonial color and morphology, and accurately differentiate between them i.e. Candida albicans, Candida tropicalis, and Candida krusei. The specificity and sensitivity of CHROMagar Candida for C. albicans calculated as 99%, for C. tropicalis calculated as 98%, and C. krusei it is 100%. Conclusion: The data presented supports the use of CHROMagar Candida for the rapid identification of Candida species directly from clinical specimens in resource-limited settings, which could be very helpful in developing appropriate therapeutic strategy and management of patients.

  8. Use of CHROMagar Candida for the presumptive identification of Candida species directly from clinical specimens in resource-limited settings.

    Science.gov (United States)

    Nadeem, Sayyada Ghufrana; Hakim, Shazia Tabassum; Kazmi, Shahana Urooj

    2010-02-09

    Identification of yeast isolated from clinical specimens to the species level has become increasingly important. Ever-increasing numbers of immuno-suppressed patients, a widening range of recognized pathogens, and the discovery of resistance to antifungal drugs are contributing factors to this necessity. A total of 487 yeast strains were studied for the primary isolation and presumptive identification, directly from clinical specimen. Efficacy of CHROMagar Candida has been evaluated with conventional methods including morphology on Corn meal-tween 80 agar and biochemical methods by using API 20 C AUX. The result of this study shows that CHROMagar Candida can easily identify three species of Candida on the basis of colonial color and morphology, and accurately differentiate between them i.e. Candida albicans, Candida tropicalis, and Candida krusei. The specificity and sensitivity of CHROMagar Candida for C. albicans calculated as 99%, for C. tropicalis calculated as 98%, and C. krusei it is 100%. The data presented supports the use of CHROMagar Candida for the rapid identification of Candida species directly from clinical specimens in resource-limited settings, which could be very helpful in developing appropriate therapeutic strategy and management of patients.

  9. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  10. Susceptibility pattern of extended spectrum beta-lactamase producing isolates in various clinical specimens

    International Nuclear Information System (INIS)

    Roshan, M.

    2011-01-01

    Objective: To determine the susceptibility pattern of extended spectrum beta-lactamase (ESBL) producing Gram negative isolates from various clinical specimens. Study Design: Descriptive study. Place and Duration of Study: Microbiology Department, Armed Forces Institute of Pathology, Rawalpindi, from January 2008 to January 2009. Methodology: A total of 308 ESBL producing isolates from various clinical specimens sent to AFIP for culture and sensitivity were identified using standard microbiological techniques and tested for antimicrobial susceptibility. At the same time screening for ESBL production was also done. ESBL production was confirmed by combination disc synergy method. The susceptibility pattern of isolates was then recorded in frequency percentages. Results: Out of the 308 ESBL producing isolates more than 99% were susceptible to carbapenems, 84% to tazobactam/ piperacillin, 81% to sulbactam/cefoperazone, 12% to fluoroquinolones, 13% to cotrimoxazole, 59% to amikacin and 18% to gentamicin. Among the urinary isolates 49% were susceptible to Nitrofurontoin and only 5% to Pipemidic acid. Conclusion: Antibiotic choices in case of ESBL producing isolates are limited and at present only carbapenems can be regarded as treatment of choice. As empirical agents, beta-lactam/beta lactamase inhibitor combinations should be used cautiously for serious infections. Fluoroquinolones showed very poor efficacy. Amikacin can be used alternatively in such cases. Nitrofurantoin is still a good oral agent for treating UTI. (author)

  11. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  12. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  13. Wildlife specimen collection, preservation, and shipment

    Science.gov (United States)

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  14. Detecting Rickettsia parkeri Infection from Eschar Swab Specimens

    Science.gov (United States)

    2013-05-01

    Detecting Rickettsia parkeri Infection from Eschar Swab Specimens Todd Myers, Tahaniyat Lalani, Mike Dent, Ju Jiang, Patrick L. Daly, Jason D...Maguire, and Allen L. Richards The typical clinical presentation of several spotted fever group Rickettsia infections includes eschars. Clinical...diagnosis by using an eschar swab specimen from patients infected with Rickettsia parkeri. Until 2004, all confirmed cases of tick-borne spotted

  15. Antimicrobial Resistance Pattern in Escherichia coli Isolates Obtained from a Specialized Women and Children Hospital in Shiraz, Iran: A Prevalence Study

    Directory of Open Access Journals (Sweden)

    Mahtab Hadadi

    2016-10-01

    Full Text Available Abstract Background: Escherichia coli, known as a clinically significant bacteria, can cause a wide range of infections, including urinary tract infections (UTIs, blood stream infections (BSIs, and can frequently be isolated from various clinical specimens. Evaluation of antimicrobial resistant pattern is a necessary action, especially about such bacteria which are frequent and life threatening. The aim of this study was to determine the frequency and antimicrobial resistance pattern of E. coli isolates obtained from various clinical specimens. Methods: This retrospective study was performed within a seven month period from January 2015 to August 2015 at a specialized women and children hospital in Shiraz, Iran. E. coli isolates were obtained from various clinical specimens and identified using standard microbiological procedure. Antimicrobial susceptibility patterns were determined using disk diffusion method in accordance with CLSI recommendation. Results: Of the total 130 positive cultures, the majority of E. coli isolates were obtained from urine (96=73.8% and blood (11=8.5% specimens. Overall, gentamicin (70.8% was the effective antibiotic for the tested E. coli isolates. E. coli isolates obtained from urine specimens showed the highest resistance rates against ampicillin (84.4% and nalidixic acid (61.5%; while they showed the most sensitivity to gentamicin (79.2%, nitrofurantoin (70.8% and ciprofloxacin (66.7%. Moreover, the highest antibiotic resistance rates belonged to the isolates recovered from endotracheal tube (ETT. Conclusion: The results showed that gentamicin was the most effective antibiotic against E. coli infections. However, in addition to the gentamicin, we can recommend nitrofurantoin and ciprofloxacin as the other effective agents for UTIs

  16. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  17. Biobanking of fresh frozen tissue from clinical surgical specimens: transport logistics, sample selection, and histologic characterization.

    Science.gov (United States)

    Botling, Johan; Micke, Patrick

    2011-01-01

    Access to high-quality fresh frozen tissue is critical for translational cancer research and molecular -diagnostics. Here we describe a workflow for the collection of frozen solid tissue samples derived from fresh human patient specimens after surgery. The routines have been in operation at Uppsala University Hospital since 2001. We have integrated cryosection and histopathologic examination of each biobank sample into the biobank manual. In this way, even small, macroscopically ill-defined lesions can be -procured without a diagnostic hazard due to the removal of uncharacterized tissue from a clinical -specimen. Also, knowledge of the histomorphology of the frozen tissue sample - tumor cell content, stromal components, and presence of necrosis - is pivotal before entering a biobank case into costly molecular profiling studies.

  18. Constructing kinetics fatigue diagrams using testing results obtained on a machine with rigid loading for specimens of various thickness

    International Nuclear Information System (INIS)

    Simin'kovich, V.N.; Gladkij, Ya.N.; Deev, N.A.

    1981-01-01

    Bending tests of 40KhS steel specimens, tempered at 200 and 500 deg C, are conducted to investigate the possible effects of specimen thickness on fatigue crack growth. Kinetic fatigue diagrams are constructed using the investigation results. An increase in crack growth with thickness is observed only in high-tempered specimens. Changes in specimen thickness do not affect crack growth in 40KhS low-tempered steel [ru

  19. Fusidic acid resistance among staphylococci strains isolated from clinical specimens

    Directory of Open Access Journals (Sweden)

    Özcan Deveci

    2012-03-01

    Full Text Available Objectives: The aim of this study was to investigate in vitrosusceptibility of fusidic acid to clinic isolates of staphylococci.Materials and methods: The forty-one coagulase negativestaphylococci (CNS and 18 Staphylococcus aureusstrains isolated from various clinical specimens were includedin this study. Staphylococci isolates were identifiedby conventional methods such as colony morphologyonto medium, gram staining, catalase and coagulasetests. According to “Clinical and Laboratory Standards Institute(CLSI” criteria, antimicrobial susceptibility testingof isolates was performed by Kirby-Bauer’s disk diffusionmethod.Results: The seventy-two percent of the isolated S.aureuswere defined as methicillin sensitive-S.aureus (MSSA,28% of the isolated S.aureus were defined as methicillinresistant-S.aureus (MRSA. The difference among fusidicacid susceptibility rates of MSSA and MRSA strains wasnot statistically significant (p=0.305. The twenty-nine percentof the isolated CNS were defined as methicillin sensitive-CNS (MS-CNS, 71% of the isolated CNS were definedas methicillin resistant-CNS (MR-CNS. There wasno statistically significant difference between MS-CNSand MR-CNS strains for fusidic acid susceptibility rates(p=0.490. But the difference among fusidic acid susceptibilityrates of CNS and S.aureus strains was statisticallysignificant (p<0.001. CNS strains were found more resistancethan S.aureus strains for fusidic acid.Conclusion: In this study, the resistance rates weredetected to increase for fusidic acid along with methicillinresistance. Among CNS isolates, fusidic acid resistancerates were significantly more elevated than that forS.aureus. Fusidic acid remains as an alternative in thetreatment of infections due to staphylococci.

  20. Antibacterial activity of amino- and amido- terminated poly (amidoamine)-G6 dendrimer on isolated bacteria from clinical specimens and standard strains

    Science.gov (United States)

    Rastegar, Ayoob; Nazari, Shahram; Allahabadi, Ahmad; Falanji, Farahnaz; Akbari Dourbash, Fakhreddin Akbari Dourbash; Rezai, Zahra; Alizadeh Matboo, Soudabeh; Hekmat-Shoar, Reza; Mohseni, Seyed Mohsen; Majidi, Gharib

    2017-01-01

    Background: Nanoscale poly (amidoamine) dendrimers have been investigated for their biological demands, but their antibacterial activity has not been widely discovered. Thus, the sixth generation of poly (amidoamine) dendrimer (PAMAM-G6) was synthesized and its antibacterial activities were evaluated on Gram-negative bacteria; P. aeruginosa, E. coli, A. baumannii, S. typhimurium, S. dysenteriae, K. pneumoniae, P. mirabilis, and Gram-positive bacteria, and S.aureus and B. subtilis, which were isolated from different clinical specimens and standard strains of these bacteria. Methods: In this study, 980 specimens including urine (47%), blood (27%), sputum (13%), wounds (8%), and burns (5%) were collected from clinical specimens of 16 hospitals and clinics in city of Sabzevar, Iran. Then, the target bacteria were isolated and identified using standard methods. Minimum inhibitory concentration and minimum bactericidal concentrations against Gram-positive and Gram-negative bacteria were determined according to guidelines described by clinical and laboratory standards institute (CLSI). Standard discs were prepared using 0.025, 0.25, 2.5, and 25 μg/mL concentrations of PAMAM-G6 on Mueller-Hinton agar plates to determinate the zone of inhibition. The cytotoxicity of PAMAM-G6 dendrimer was evaluated in HCT116 cells by MTT assay. Results: The most important isolated bacteria were E. coli (23.65%), S. aureus (24.7%), P. aeruginosa (10.49%), B. subtilis (7.7%), S. typhimurium (8.87%), A. baumannii (7.02%), K. pneumoniae (7.1%), P. mirabilis (6.46%), and S. dysenteriae (3.6%). Moreover, it was found that poly (amidoamine)–G6 exhibited more antibacterial efficacy on standard strains than isolated bacteria from clinical samples (p<0.05). The cytotoxicity of PAMAM-G6 to the cells showed that cytotoxicity depended on the concentration level and exposure time. Conclusion: The PAMAM-G6 dendrimer showed a positive impact on the removal of dominant bacterial isolated from clinical

  1. Detection of enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification.

    Science.gov (United States)

    Wang, D; Wang, X; Geng, Y; An, C

    2014-01-01

    The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD) for an early treatment by using loop-mediated isothermal amplification (LAMP) technique. A reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conventional reverse-transcription polymerase chain reaction (RT-PCR) and real-time PCR. A total of 116 clinical specimens from the suspected HFMD individual were detected with the RT-LAMP. The detection rate for EV71 was 56.89% by RT-LAMP, 41.38% by real-time PCR and 34.48% by RT-PCR. The minimum detection limit of RT-LAMP was 0.01 PFU, both of RT-PCR and real-time PCR was 0.1PFU. Non-cross-reactive amplification with other enteroviruses was detected in the survey reports. The effectiveness of RT-LAMP is higher than RT-PCR and real-time PCR. The protocol is easy to operate and time saving. It was not an expensive instrument, which was needed; it is an applicable method for rapid diagnosis of the disease, especially in resource-poor countries or in developing countries.

  2. Line probe assay for differentiation within Mycobacterium tuberculosis complex. Evaluation on clinical specimens and isolates including Mycobacterium pinnipedii

    DEFF Research Database (Denmark)

    Kjeldsen, Marianne Kirstine; Bek, Dorte; Rasmussen, Erik Michael

    2009-01-01

    A line probe assay (GenoType MTBC) was evaluated for species differentiation within the Mycobacterium tuberculosis complex (MTBC). We included 387 MTBC isolates, 43 IS6110 low-copy MTBC isolates, 28 clinical specimens with varying microscopy grade, and 30 isolates of non-tuberculous mycobacteria...

  3. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Obtaining and Using Images in the Clinical Setting

    International Nuclear Information System (INIS)

    Cendales, Ricardo

    2009-01-01

    Currently small electronic devices capable of producing high quality images are available. The massive use of these devices has become common in the clinical setting as medical images represent a useful tool to document relevant clinical conditions for patient diagnosis, treatment and follow-up. Besides, clinical images are beneficial for legal, scientific and academic purposes. The extended practice without proper ethical guidelines might represent a significant risk for the protection of patient rights and clinical practice. This document discusses risks and duties when obtaining medical images, and presents some arguments on institutional and professional responsibilities around the definition of policies regarding the protection of privacy and dignity of the patient.

  5. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  6. Application of subsize specimens in nuclear plant life extension

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  7. Detection and Differentiation of Leishmania spp. in Clinical Specimens by Use of a SYBR Green-Based Real-Time PCR Assay.

    Science.gov (United States)

    de Almeida, Marcos E; Koru, Ozgur; Steurer, Francis; Herwaldt, Barbara L; da Silva, Alexandre J

    2017-01-01

    Leishmaniasis in humans is caused by Leishmania spp. in the subgenera Leishmania and Viannia Species identification often has clinical relevance. Until recently, our laboratory relied on conventional PCR amplification of the internal transcribed spacer 2 (ITS2) region (ITS2-PCR) followed by sequencing analysis of the PCR product to differentiate Leishmania spp. Here we describe a novel real-time quantitative PCR (qPCR) approach based on the SYBR green technology (LSG-qPCR), which uses genus-specific primers that target the ITS1 region and amplify DNA from at least 10 Leishmania spp., followed by analysis of the melting temperature (T m ) of the amplicons on qPCR platforms (the Mx3000P qPCR system [Stratagene-Agilent] and the 7500 real-time PCR system [ABI Life Technologies]). We initially evaluated the assay by testing reference Leishmania isolates and comparing the results with those from the conventional ITS2-PCR approach. Then we compared the results from the real-time and conventional molecular approaches for clinical specimens from 1,051 patients submitted to the reference laboratory of the Centers for Disease Control and Prevention for Leishmania diagnostic testing. Specimens from 477 patients tested positive for Leishmania spp. with the LSG-qPCR assay, specimens from 465 of these 477 patients also tested positive with the conventional ITS2-PCR approach, and specimens from 10 of these 465 patients had positive results because of retesting prompted by LSG-qPCR positivity. On the basis of the T m values of the LSG-qPCR amplicons from reference and clinical specimens, we were able to differentiate four groups of Leishmania parasites: the Viannia subgenus in aggregate; the Leishmania (Leishmania) donovani complex in aggregate; the species L (L) tropica; and the species L (L) mexicana, L (L) amazonensis, L (L) major, and L (L) aethiopica in aggregate. Copyright © 2016 American Society for Microbiology.

  8. Acceptability and feasibility of repeated mucosal specimen collection in clinical trial participants in Kenya.

    Directory of Open Access Journals (Sweden)

    Gloria Omosa-Manyonyi

    Full Text Available Mucosal specimens are essential to evaluate compartmentalized immune responses to HIV vaccine candidates and other mucosally targeted investigational products. We studied the acceptability and feasibility of repeated mucosal sampling in East African clinical trial participants at low risk of HIV and other sexually transmitted infections.The Kenya AIDS Vaccine Initiative (KAVI enrolled participants into three Phase 1 trials of preventive HIV candidate vaccines in 2011-2012 at two clinical research centers in Nairobi. After informed consent to a mucosal sub-study, participants were asked to undergo collection of mucosal secretions (saliva, oral fluids, semen, cervico-vaginal and rectal, but could opt out of any collection at any visit. Specimens were collected at baseline and two additional time points. A tolerability questionnaire was administered at the final sub-study visit. Of 105 trial participants, 27 of 34 women (79% and 62 of 71 men (87% enrolled in the mucosal sub-study. Nearly all sub-study participants gave saliva and oral fluids at all visits. Semen was collected from about half the participating men (47-48% at all visits. Cervico-vaginal secretions were collected by Softcup from about two thirds of women (63% at baseline, increasing to 78% at the following visits, with similar numbers for cervical secretion collection by Merocel sponge; about half of women (52% gave cervico-vaginal samples at all visits. Rectal secretions were collected with Merocel sponge from about a quarter of both men and women (24% at all 3 visits, with 16% of men and 19% of women giving rectal samples at all visits.Repeated mucosal sampling in clinical trial participants in Kenya is feasible, with a good proportion of participants consenting to most sampling methods with the exception of rectal samples. Experienced staff members of both sexes and trained counselors with standardized messaging may improve acceptance of rectal sampling.

  9. Detection of Enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification

    OpenAIRE

    D Wang; X Wang; Y Geng; C An

    2014-01-01

    Purpose : The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD) for an early treatment by using loop-mediated isothermal amplification (LAMP) technique. Materials and Methods : A reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conven...

  10. Improved detection of Burkholderia pseudomallei from non-blood clinical specimens using enrichment culture and PCR: narrowing diagnostic gap in resource-constrained settings.

    Science.gov (United States)

    Tellapragada, Chaitanya; Shaw, Tushar; D'Souza, Annet; Eshwara, Vandana Kalwaje; Mukhopadhyay, Chiranjay

    2017-07-01

    To evaluate the diagnostic utility of enrichment culture and PCR for improved case detection rates of non-bacteraemic form of melioidosis in limited resource settings. Clinical specimens (n = 525) obtained from patients presenting at a tertiary care hospital of South India with clinical symptoms suggestive of community-acquired pneumonia, lower respiratory tract infections, superficial or internal abscesses, chronic skin ulcers and bone or joint infections were tested for the presence of Burkholderia pseudomallei using conventional culture (CC), enrichment culture (EC) and PCR. Sensitivity, specificity, positive and negative predictive values of CC and PCR were initially deduced using EC as the gold standard method. Further, diagnostic accuracies of all the three methods were analysed using Bayesian latent class modelling (BLCM). Detection rates of B. pseudomallei using CC, EC and PCR were 3.8%, 5.3% and 6%, respectively. Diagnostic sensitivities and specificities of CC and PCR were 71.4, 98.4% and 100 and 99.4%, respectively in comparison with EC as the gold standard test. With Bayesian latent class modelling, EC and PCR demonstrated sensitivities of 98.7 and 99.3%, respectively, while CC showed a sensitivity of 70.3% for detection of B. pseudomallei. An increase of 1.6% (95% CI: 1.08-4.32%) in the case detection rate of melioidosis was observed in the study population when EC and/or PCR were used in adjunct to the conventional culture technique. Our study findings underscore the diagnostic superiority of enrichment culture and/or PCR over conventional microbiological culture for improved case detection of melioidosis from non-blood clinical specimens. © 2017 John Wiley & Sons Ltd.

  11. Detection of Enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification

    Directory of Open Access Journals (Sweden)

    D Wang

    2014-01-01

    Full Text Available Purpose : The objective of this study was to develop a sensitive, specific and rapid approach to diagnose hand foot and mouth disease (HFMD for an early treatment by using loop-mediated isothermal amplification (LAMP technique. Materials and Methods : A reverse-transcription loop-mediated isothermal amplification (RT-LAMP for detecting EV71 virus was developed, the specificity and sensitivity of RT-LAMP was tested, and the clinical specimens was assayed by the RT-LAMP comparing with conventional reverse-transcription polymerase chain reaction (RT-PCR and real-time PCR. Results : A total of 116 clinical specimens from the suspected HFMD individual were detected with the RT-LAMP. The detection rate for EV71 was 56.89% by RT-LAMP, 41.38% by real-time PCR and 34.48% by RT-PCR. The minimum detection limit of RT-LAMP was 0.01 PFU, both of RT-PCR and real-time PCR was 0.1PFU. Non-cross-reactive amplification with other enteroviruses was detected in the survey reports. Conclusions : The effectiveness of RT-LAMP is higher than RT-PCR and real-time PCR. The protocol is easy to operate and time saving. It was not an expensive instrument, which was needed; it is an applicable method for rapid diagnosis of the disease, especially in resource-poor countries or in developing countries.

  12. SHOULD EVERY APPENDECECTOMY SPECIMEN BE SUBJECTED TO HISTOPATHOLOGICAL EXAMINATION? A RETROSPECTIVE STUDY OF HISTOLOGICAL FINDINGS IN APPENDICECTOMY SPECIMENS

    Directory of Open Access Journals (Sweden)

    Shahanuma Shaik

    2017-12-01

    Full Text Available BACKGROUND Appendicitis is one of the commonest surgical emergencies with a lifetime risk of 7-8%. The appendicectomy specimens operated upon clinically-suspected appendicitis often appear normal on gross examination, but histopathological evaluation may reveal a diverse underlying pathology. Therefore, for accurate diagnosis, histopathological examination of all appendicectomy specimens is mandatory. MATERIALS AND METHODS A retrospective study of 175 appendicectomy cases operated over a period of two years. The clinical data and histopathological reports were reviewed and various histopathological findings are categorised. RESULTS Out of the total 175 appendicectomies, 155 emergency appendicectomy cases were included in the study, while 20 cases of incidental appendicectomy were excluded. The peak incidence was found in the 2nd and 3rd decades with male predominance. Among the 155 specimens, 96.8% had histological features of appendicitis and 1.9% were normal appendix. The unusual histopathological findings were Carcinoid tumour and Enterobius vermicularis. CONCLUSION The definitive diagnoses of appendicitis as well as the unusual incidental findings that were missed intraoperatively are established by histopathological examination. The study supports the histological examination of all resected appendicectomy specimens.

  13. Comparison of specimen adequacy in fine-needle aspiration biopsies performed by surgeons and pathologists

    International Nuclear Information System (INIS)

    Al-Marzooq, Yusef M.; Chopra, Rajan; Al-Bahrani, Ahmed T.; Younis, Mohammad; Al-Mulhim, Abdulrahman S.; Al-Mommatten, Mohammed I.

    2004-01-01

    Fine-needle aspiration biopsy (FNAB) may yield different results depending on its operator. We compared the proportions of unsatisfactory aspirates obtained by pathologists vs. surgeons. In a retrospective review, all FNAB reports and slides performed between March 2002 and February 2003 were grouped by organ/site and according to whether they were done by pathologist or a surgeon. The proportions of unsatisfactory aspirates for pathologists and surgeons were compared. Of 692 FNAB's, 390 were performed by pathologists at the FNAC clinic and the remainder by surgeons. Overall, 15.5% of aspirates obtained were unsatisfactory (n=107). Of aspirates obtained by surgeons, 29.5% were unsatisfactory, compared to 4.6% of those obtained by pathologists (P<0.001). Pathologists had significantly lower proportions of unsatisfactory aspirates in all sites. A 33% reduction in the number of lymph node excisional biopsies has been reported subsequent to establishment of the FNAC clinic. The advantages of a pathologist performing FNAB are that a rapid evaluation can be rendered regarding specimen adequacy and the need for repeating the procedure. In addition, pathologists can direct the distribution of aspirated material for other tests such as culture study, flow cytometry and electron microscopy, as indicated by preliminary evaluation of the smears. These factors significantly lower the proportions of unsatisfactory specimens and improve the diagnstic accuracy of FNAB technique. (author)

  14. Quantitative X-ray microanalysis of biological specimens

    International Nuclear Information System (INIS)

    Roomans, G.M.

    1988-01-01

    Qualitative X-ray microanalysis of biological specimens requires an approach that is somewhat different from that used in the materials sciences. The first step is deconvolution and background subtraction on the obtained spectrum. The further treatment depends on the type of specimen: thin, thick, or semithick. For thin sections, the continuum method of quantitation is most often used, but it should be combined with an accurate correction for extraneous background. However, alternative methods to determine local mass should also be considered. In the analysis of biological bulk specimens, the ZAF-correction method appears to be less useful, primarily because of the uneven surface of biological specimens. The peak-to-local background model may be a more adequate method for thick specimens that are not mounted on a thick substrate. Quantitative X-ray microanalysis of biological specimens generally requires the use of standards that preferably should resemble the specimen in chemical and physical properties. Special problems in biological microanalysis include low count rates, specimen instability and mass loss, extraneous contributions to the spectrum, and preparative artifacts affecting quantitation. A relatively recent development in X-ray microanalysis of biological specimens is the quantitative determination of local water content

  15. Validity of fracture toughness determined with small bend specimens

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  16. Comparison of real-time and quantitative polymerase chain reaction assays in detection of cytomegalovirus DNA in clinical specimens

    International Nuclear Information System (INIS)

    Gokahmetoglu, S.; Deniz, E.

    2007-01-01

    To compare the real-time (RT) and qualitative (Q) polymerase chain reaction (PCR) assays for detection of Cytomegalovirus (CMV) DNA. The study took place in the Department of Microbiology, Erciyes University, Kayseri and in Iontek Laboratory, Istanbul, Turkey, from August to December 2006. One hundred and seven clinical specimens from 67 patients were included in the study. Cytomegalovirus DNA was investigated using RT-PCR kit (Fluorion Iontek, Turkey) and Q-PCR kit (Fluorion Iontek, Turkey). Deoxyribonucleic acid sequencing was applied to the samples that yielded discrepant results in both assays. Mac Nema's Chi Square test was used for statistical analysis. Of the specimens, 27 were found positive with both assays: 9 with only RT-PCR, and 11 with only Q-PCR assay. Both assays were found negative in 60 of the specimens. There was a good agreement between the 2 assays in 87(81.3%) of the specimens. There was no statistical significant difference between the assays (p>0.05). Two of the 11 samples that RT-PCR negative Q-PCR positive, and 3 of 9 samples that RT-PCR positive Q-PCR negative were found to be CMV DNA positive by DNA sequencing. A good level of concordance between RT-PCR and Q-PCR assays for CMV DNA detection has been found. (author)

  17. Molecular epidemiology of Bordetella pertussis in Cambodia determined by direct genotyping of clinical specimens.

    Science.gov (United States)

    Moriuchi, Takumi; Vichit, Ork; Vutthikol, Yong; Hossain, Md Shafiqul; Samnang, Chham; Toda, Kohei; Grabovac, Varja; Hiramatsu, Yukihiro; Otsuka, Nao; Shibayama, Keigo; Kamachi, Kazunari

    2017-09-01

    This study sought to determine the genotypes of circulating Bordetella pertussis, the causative agent of pertussis, in Cambodia by direct molecular typing of clinical specimens. DNA extracts from nasopharyngeal swabs obtained from 82 pertussis patients in 2008-2016 were analyzed by multilocus variable-number tandem repeat analysis (MLVA). B. pertussis virulence-associated allelic genes (ptxA, prn, and fim3) and the pertussis toxin promoter ptxP were also investigated by DNA sequence-based typing. Forty-four DNA extracts (54%) yielded a complete MLVA profile, and these were sorted into 8 MLVA types (MT18, MT26, MT27, MT29, MT43, MT72, MT95, and MT200). MT27 and MT29, which are common in developed countries, were the predominant strain types (total 73%). The predominant profile of virulence-associated allelic genes was the combination of ptxP3/ptxA1/prn2/fim3A (48%). MT27 strains were detected during the entire study period, whereas MT29 strains were only found in 2014-2016. The B. pertussis population in Cambodia, where a whole-cell pertussis vaccine (WCV) has been continuously used, resembled those observed previously in developed countries where acellular pertussis vaccines are used. Circulating B. pertussis strains in Cambodia were distinct from those in other countries using WCVs. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  18. Comparison of automated microarray detection with real-time PCR assays for detection of respiratory viruses in specimens obtained from children.

    Science.gov (United States)

    Raymond, Frédéric; Carbonneau, Julie; Boucher, Nancy; Robitaille, Lynda; Boisvert, Sébastien; Wu, Whei-Kuo; De Serres, Gaston; Boivin, Guy; Corbeil, Jacques

    2009-03-01

    Respiratory virus infections are a major health concern and represent the primary cause of testing consultation and hospitalization for young children. We developed and compared two assays that allow the detection of up to 23 different respiratory viruses that frequently infect children. The first method consisted of single TaqMan quantitative real-time PCR assays in a 96-well-plate format. The second consisted of a multiplex PCR followed by primer extension and microarray hybridization in an integrated molecular diagnostic device, the Infiniti analyzer. Both of our assays can detect adenoviruses of groups A, B, C, and E; coronaviruses HKU1, 229E, NL63, and OC43; enteroviruses A, B, C, and D; rhinoviruses of genotypes A and B; influenza viruses A and B; human metapneumoviruses (HMPV) A and B, human respiratory syncytial viruses (HRSV) A and B; and parainfluenza viruses of types 1, 2, and 3. These tests were used to identify viruses in 221 nasopharyngeal aspirates obtained from children hospitalized for respiratory tract infections. Respiratory viruses were detected with at least one of the two methods in 81.4% of the 221 specimens: 10.0% were positive for HRSV A, 38.0% for HRSV B, 13.1% for influenzavirus A, 8.6% for any coronaviruses, 13.1% for rhinoviruses or enteroviruses, 7.2% for adenoviruses, 4.1% for HMPV, and 1.5% for parainfluenzaviruses. Multiple viral infections were found in 13.1% of the specimens. The two methods yielded concordant results for 94.1% of specimens. These tests allowed a thorough etiological assessment of respiratory viruses infecting children in hospital settings and would assist public health interventions.

  19. Comparison of Automated Microarray Detection with Real-Time PCR Assays for Detection of Respiratory Viruses in Specimens Obtained from Children▿

    Science.gov (United States)

    Raymond, Frédéric; Carbonneau, Julie; Boucher, Nancy; Robitaille, Lynda; Boisvert, Sébastien; Wu, Whei-Kuo; De Serres, Gaston; Boivin, Guy; Corbeil, Jacques

    2009-01-01

    Respiratory virus infections are a major health concern and represent the primary cause of testing consultation and hospitalization for young children. We developed and compared two assays that allow the detection of up to 23 different respiratory viruses that frequently infect children. The first method consisted of single TaqMan quantitative real-time PCR assays in a 96-well-plate format. The second consisted of a multiplex PCR followed by primer extension and microarray hybridization in an integrated molecular diagnostic device, the Infiniti analyzer. Both of our assays can detect adenoviruses of groups A, B, C, and E; coronaviruses HKU1, 229E, NL63, and OC43; enteroviruses A, B, C, and D; rhinoviruses of genotypes A and B; influenza viruses A and B; human metapneumoviruses (HMPV) A and B, human respiratory syncytial viruses (HRSV) A and B; and parainfluenza viruses of types 1, 2, and 3. These tests were used to identify viruses in 221 nasopharyngeal aspirates obtained from children hospitalized for respiratory tract infections. Respiratory viruses were detected with at least one of the two methods in 81.4% of the 221 specimens: 10.0% were positive for HRSV A, 38.0% for HRSV B, 13.1% for influenzavirus A, 8.6% for any coronaviruses, 13.1% for rhinoviruses or enteroviruses, 7.2% for adenoviruses, 4.1% for HMPV, and 1.5% for parainfluenzaviruses. Multiple viral infections were found in 13.1% of the specimens. The two methods yielded concordant results for 94.1% of specimens. These tests allowed a thorough etiological assessment of respiratory viruses infecting children in hospital settings and would assist public health interventions. PMID:19158263

  20. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  1. Characterization of Human Cytomegalovirus Genome Diversity in Immunocompromised Hosts by Whole-Genome Sequencing Directly From Clinical Specimens.

    Science.gov (United States)

    Hage, Elias; Wilkie, Gavin S; Linnenweber-Held, Silvia; Dhingra, Akshay; Suárez, Nicolás M; Schmidt, Julius J; Kay-Fedorov, Penelope C; Mischak-Weissinger, Eva; Heim, Albert; Schwarz, Anke; Schulz, Thomas F; Davison, Andrew J; Ganzenmueller, Tina

    2017-06-01

    Advances in next-generation sequencing (NGS) technologies allow comprehensive studies of genetic diversity over the entire genome of human cytomegalovirus (HCMV), a significant pathogen for immunocompromised individuals. Next-generation sequencing was performed on target enriched sequence libraries prepared directly from a variety of clinical specimens (blood, urine, breast milk, respiratory samples, biopsies, and vitreous humor) obtained longitudinally or from different anatomical compartments from 20 HCMV-infected patients (renal transplant recipients, stem cell transplant recipients, and congenitally infected children). De novo-assembled HCMV genome sequences were obtained for 57 of 68 sequenced samples. Analysis of longitudinal or compartmental HCMV diversity revealed various patterns: no major differences were detected among longitudinal, intraindividual blood samples from 9 of 15 patients and in most of the patients with compartmental samples, whereas a switch of the major HCMV population was observed in 6 individuals with sequential blood samples and upon compartmental analysis of 1 patient with HCMV retinitis. Variant analysis revealed additional aspects of minor virus population dynamics and antiviral-resistance mutations. In immunosuppressed patients, HCMV can remain relatively stable or undergo drastic genomic changes that are suggestive of the emergence of minor resident strains or de novo infection. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  3. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  4. Anaerobic Bacteria in Clinical Specimens - Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital.

    Science.gov (United States)

    Shenoy, Padmaja Ananth; Vishwanath, Shashidhar; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-07-01

    Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections.

  5. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    Science.gov (United States)

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  6. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  7. Handling of biological specimens for electron microscopy

    International Nuclear Information System (INIS)

    Bullock, G.

    1987-01-01

    There are many different aspects of specimen preparation procedure which need to be considered in order to achieve good results. Whether using the scanning or transmission microscope, the initial handling procedures are very similar and are selected for the information required. Handling procedures and techniques described are: structural preservation; immuno-and histo-chemistry; x-ray microanalysis and autoradiography; dehydration and embedding; mounting and coating specimens for scanning electron microscopy; and sectioning of resin embedded material. With attention to detail and careful choice of the best available technique, excellent results should be obtainable whatever the specimen. 6 refs

  8. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  9. Fracture toughness of Charpy-size compound specimens and its application in engineering

    International Nuclear Information System (INIS)

    Zhang, X.P.; Shi, Y.W.

    1994-01-01

    The use of a pre-cracked Charpy-size specimen with a side-groove to evaluate the fracture toughness of materials has been researched and considered. This method not only satisfies the demand for small-size specimens in surveillance tests of fracture toughness but also avoids using complicated physical methods to monitor the initial conditions of crack propagation. For most materials this method has solved the problem in which the small-size specimen did not satisfy the valid conditions of a fracture toughness measurement. In order to obtain more information from neutron-irradiated sample specimens and raise the reliability of fracture toughness surveillance tests, it has been considered more important to repeatedly exploit the broken Charpy-size specimen tested in the surveillance test, and to make it renewable. In this work, on the renewing design and utilization of Charpy-size specimens, nine data on fracture toughness can be obtained from one pre-cracked side-grooved Charpy-size specimen, while at present usually only one to three data on fracture toughness can be obtained from one Charpy-size specimen. Thus, it is found that the new method would improve the reliability of fracture toughness surveillance testing and evaluation. In addition, some factors that affect the optimum design of pre-cracked deep side-groove Charpy-size compound specimens have also been discussed. (author)

  10. PREVALENCE OF ACINETOBACTER BAUMANNII ISOLATED FROM CLINICAL SPECIMENS IN ADAM MALIK HOSPITAL

    Directory of Open Access Journals (Sweden)

    Evita Mayasari

    2014-05-01

    Full Text Available AbstrakAcinetobacter baumannii merupakan spesies Acinetobacter spp. tersering diisolasi darimanusia, dan lebih sering dijumpai pada infeksi nosokomial dibandingkan dengan infeksi dikomunitas. Eksistensi bakteri ini di lingkungan terkait dengan keragaman reservoir, kemampuanmemperoleh gen pembawa sifat resisten antimikroba, dan sifat resisten terhadap pengeringan.Infeksi disebabkan strain A.baumannii yang resisten terhadap banyak antibiotik tidak mudahdikendalikan dan menjadi permasalahan di berbagai negara. Penelitian ini bertujuan untukmengetahui prevalensi A.baumannii dari spesimen klinis di instalasi mikrobiologi klinik RSUPHaji Adam Malik serta pola kepekaannya terhadap berbagai antibiotik. Identifikasi dan ujikepekaan menggunakan mesin otomatis Vitek 2 dengan Advanced Expert System (AES.Penelitian ini menemukan 644/3693 (17,44% isolat A.baumannii dari berbagai spesimen klinis.A.baumannii paling banyak diisolasi dari spesimen dahak. Penelitian ini menemukan 147/644(23% bahwa isolat carbapenem-resistent A.baumannii (imipenem dan meropenem. Sebagianbesar isolat sensitif terhadap colistin, amikacin dan tigecycline. Prevalensi A.baumanni yangditemukan pada penelitian ini adalah rendah namun resistensinya tinggi terhadap antibiotikterutama golongan penicillin, cephalosporin dan fluoroquinolon.AbstractAcinetobacter baumannii is the most frequent species of Acinetobacter spp. isolated fromhumans and more common in nosocomial infection than it is in community acquired infection.A.baumannii existence in environment is associated with the diversity of its reservoirs, itscapacity to accumulate genes of antimicrobial resistence, and its resistence to desiccation.Infection of Multidrug resistent (MDR strain of A.baumannii is not easy to manage and it hasbecome a problem in many countries. The aim of this retrospective study was to investigatethe prevalence of A.baumannii from routine clinical specimens sent to clinical microbiologylaboratory RSUP HAM

  11. Production of 16N and obtaining of its gamma spectrum in order to calibrate detectors or determination of fluorine in geological specimens

    International Nuclear Information System (INIS)

    Rey-Ronco, M.A.; Alonso-Sanchez, T.; Castro-Garcia, M.P.

    2010-01-01

    In this paper, we show a procedure for producing 16 N and a method to obtain its gamma spectrum with a NaI(Tl) detector. We also demonstrate the interest of this radioactive element for the purpose of NaI(Tl) detector calibration and for the determination of fluorine in geological specimens using an Alpha Beryllium neutron source. This work consists of a theoretical study which analyzes the characteristics of 16 N and nuclear reactions that originate from an Americium Beryllium source of 1Ci activity. We justify our choice of reaction 19 F(n,α) 16 N and the use of fluorspar as a source of fluorine. The mathematical procedure followed to obtain the gamma rays spectrum produced by 16 N in a NaI(Tl) detector is shown.

  12. Anaerobic Bacteria in Clinical Specimens – Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital

    Science.gov (United States)

    Shenoy, Padmaja Ananth; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-01-01

    Introduction Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. Aim To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. Materials and Methods A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Results Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Conclusion Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections. PMID:28892897

  13. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    Science.gov (United States)

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Production of {sup 16}N and obtaining of its gamma spectrum in order to calibrate detectors or determination of fluorine in geological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Rey-Ronco, M.A., E-mail: rey@uniovi.e [Departamento de Energia, Universidad de Oviedo, 33004 Oviedo (Spain); Alonso-Sanchez, T., E-mail: tjalonso@uniovi.e [Departamento de Explotacion y Prospeccion de Minas, Universidad de Oviedo, 33004 Oviedo (Spain); Castro-Garcia, M.P., E-mail: UO21947@uniovi.e [Departamento de Explotacion y Prospeccion de Minas, Universidad de Oviedo, 33004 Oviedo (Spain)

    2010-09-15

    In this paper, we show a procedure for producing {sup 16}N and a method to obtain its gamma spectrum with a NaI(Tl) detector. We also demonstrate the interest of this radioactive element for the purpose of NaI(Tl) detector calibration and for the determination of fluorine in geological specimens using an Alpha Beryllium neutron source. This work consists of a theoretical study which analyzes the characteristics of {sup 16}N and nuclear reactions that originate from an Americium Beryllium source of 1Ci activity. We justify our choice of reaction {sup 19}F(n,{alpha}){sup 16}N and the use of fluorspar as a source of fluorine. The mathematical procedure followed to obtain the gamma rays spectrum produced by {sup 16}N in a NaI(Tl) detector is shown.

  15. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  16. Mesh-morphing algorithms for specimen-specific finite element modeling.

    Science.gov (United States)

    Sigal, Ian A; Hardisty, Michael R; Whyne, Cari M

    2008-01-01

    Despite recent advances in software for meshing specimen-specific geometries, considerable effort is still often required to produce and analyze specimen-specific models suitable for biomechanical analysis through finite element modeling. We hypothesize that it is possible to obtain accurate models by adapting a pre-existing geometry to represent a target specimen using morphing techniques. Here we present two algorithms for morphing, automated wrapping (AW) and manual landmarks (ML), and demonstrate their use to prepare specimen-specific models of caudal rat vertebrae. We evaluate the algorithms by measuring the distance between target and morphed geometries and by comparing response to axial loading simulated with finite element (FE) methods. First a traditional reconstruction process based on microCT was used to obtain two natural specimen-specific FE models. Next, the two morphing algorithms were used to compute mappings from the surface of one model, the source, to the other, the target, and to use this mapping to morph the source mesh to produce a target mesh. The microCT images were then used to assign element-specific material properties. In AW the mappings were obtained by wrapping the source and target surfaces with an auxiliary triangulated surface. In ML, landmarks were manually placed on corresponding locations on the surfaces of both source and target. Both morphing algorithms were successful in reproducing the shape of the target vertebra with a median distance between natural and morphed models of 18.8 and 32.2 microm, respectively, for AW and ML. Whereas AW-morphing produced a surface more closely resembling that of the target, ML guaranteed correspondence of the landmark locations between source and target. Morphing preserved the quality of the mesh producing models suitable for FE simulation. Moreover, there were only minor differences between natural and morphed models in predictions of deformation, strain and stress. We therefore conclude that

  17. Detection of Histoplasma capsulatum from clinical specimens by cycling probe-based real-time PCR and nested real-time PCR.

    Science.gov (United States)

    Muraosa, Yasunori; Toyotome, Takahito; Yahiro, Maki; Watanabe, Akira; Shikanai-Yasuda, Maria Aparecida; Kamei, Katsuhiko

    2016-05-01

    We developed new cycling probe-based real-time PCR and nested real-time PCR assays for the detection of Histoplasma capsulatum that were designed to detect the gene encoding N-acetylated α-linked acidic dipeptidase (NAALADase), which we previously identified as an H. capsulatum antigen reacting with sera from patients with histoplasmosis. Both assays specifically detected the DNAs of all H. capsulatum strains but not those of other fungi or human DNA. The limited of detection (LOD) of the real-time PCR assay was 10 DNA copies when using 10-fold serial dilutions of the standard plasmid DNA and 50 DNA copies when using human serum spiked with standard plasmid DNA. The nested real-time PCR improved the LOD to 5 DNA copies when using human serum spiked with standard plasmid DNA, which represents a 10-fold higher than that observed with the real-time PCR assay. To assess the ability of the two assays to diagnose histoplasmosis, we analyzed a small number of clinical specimens collected from five patients with histoplasmosis, such as sera (n = 4), formalin-fixed paraffin-embedded (FFPE) tissue (n = 4), and bronchoalveolar lavage fluid (BALF) (n = 1). Although clinical sensitivity of the real-time PCR assay was insufficiently sensitive (33%), the nested real-time PCR assay increased the clinical sensitivity (77%), suggesting it has a potential to be a useful method for detecting H. capsulatum DNA in clinical specimens. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Improved diagnosis of Trichomonas vaginalis infection by PCR using vaginal swabs and urine specimens compared to diagnosis by wet mount microscopy, culture, and fluorescent staining

    NARCIS (Netherlands)

    C. van der Schee (Cindy); A.F. van Belkum (Alex); L. Zwijgers (Lisette); E. van der Brugge; E.L. O'Neill; A. Luijendijk (Ad); T. van Rijsoort-Vos; W.I. van der Meijden (Willem); J.F. Sluiters (Hans); H.A. Verbrugh (Henri)

    1999-01-01

    textabstractFour vaginal cotton swab specimens were obtained from each of 804 women visiting the outpatient sexually transmitted disease clinic of the Erasmus University Medical Center Rotterdam, Rotterdam, The Netherlands, for validation of various forms of Trichomonas

  19. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  20. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  1. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  2. A cylindrical specimen holder for electron cryo-tomography

    International Nuclear Information System (INIS)

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  3. Clinical map document based on XML (cMDX): document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens.

    Science.gov (United States)

    Eminaga, Okyaz; Hinkelammert, Reemt; Semjonow, Axel; Neumann, Joerg; Abbas, Mahmoud; Koepke, Thomas; Bettendorf, Olaf; Eltze, Elke; Dugas, Martin

    2010-11-15

    The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa). The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension) with the textual data (e.g. histological patterns). The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25). 54% of PCa showed a multifocal growth pattern. cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis.

  4. Elemental microanalysis of botanical specimens using the Melbourne Proton Microprobe

    International Nuclear Information System (INIS)

    Mazzolini, A.P.J.; Legge, G.J.F.

    1978-01-01

    A proton microprobe has been used to obtain the distribution of elements of various botanical specimens. This paper presents preliminary results obtained by the irradiation of certain organs of the wheat plant

  5. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    International Nuclear Information System (INIS)

    Fukuda, Hozumi; Ibukuro, Kenji; Tsukiyama, Toshitaka; Ishii, Rei

    2004-01-01

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which were therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis

  6. Correlation of clinical data with fallopian tube specimen immune cells and tissue culture capacity.

    Science.gov (United States)

    Ramraj, Satish Kumar; Smith, Katie M; Janakiram, Naveena B; Toal, Coralee; Raman, Ankita; Benbrook, Doris Mangiaracina

    2018-06-01

    Human fallopian tube fimbria secretory epithelial cells (hFTSECs) are considered an origin of ovarian cancer and methods for their culture from fallopian tube specimens have been reported. Our objective was to determine whether characteristics of the donors or surgeries were associated with the capacities of fimbria specimens to generate hFTSEC cultures or their immune profiles. There were no surgical complications attributable to fallopian tube removal. Attempts to establish primary hFTSEC cultures were successful in 37 of 55 specimens (67%). Success rates did not differ significantly between specimens grouped by patient or surgery characteristics. Established cultures could be revived after cryopreservation and none became contaminated with microorganisms. Two cultures evaluated for long term growth senesced between passages 10 and 15. M1 macrophages were the predominant cell type, while all other immune cells were present at much lower percentages. IL-10 and TGF-β exhibited opposing trends with M1 and M2 macrophages. Plasma IL-10 levels exhibited significant positive correlation with patient age. In conclusion, fallopian tube fimbria specimens exhibit a pro-inflammatory phenotype and can be used to provide a source of hFTSECs that can be cultured for a limited time regardless of the donor patient age or race, or the type of surgery performed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Metallo- β-lactamases among Multidrug Resistant (MDR Gram Negative Bacteria Isolated from Clinical Specimens during 2009 in Sanandaj, Kurdistan Province

    Directory of Open Access Journals (Sweden)

    Himen Salimizand

    2012-08-01

    Full Text Available Background: Today, there are numerous reports about emerging multi drug resistant gram negative bacteria all around the world, especially in ICUs. Rarely, Metallo-β-lactamase (MBL enzymes are responsible for these cases. Study of MBLs for diagnosing and preventing distribution of the origin of infection are critical issues. In addition, we would like to compare the efficacy of Iranian and foreign- made antibiotic disks. Materials and Methods: During 2009 all entered clinical specimens to the laboratory tested for detecting gram negative bacteria. Isolated bacteria were tested by Kirby-Bauer method to antibiotic susceptibility test by Iranian and foreign (MAST disks. For gram negative carbapenem resistant isolates, PCR technique used to detect VIM, GIM, and SIM variants of MBLs.Results: During one year, 17890 clinical specimens referred Besat laboratory. The most specimen was Urine (8172 followed by blood culture (5190 that in which 1110 gram negative and positives isolated. Out of which, 778 (70% of isolates were gram negatives. MDR gram negatives were 157 (20.2%. Imipenem and meropenem were the most efficient antibiotics (all susceptible and ceftriaxone was the least (19 % susceptible. E. coli was the most prevalent isolate. 79 Gram negative isolates (10.1% were resistant to Iranian-made discs but all susceptible for foreign ones. All 79 isolates were tested by PCR for MBL genes, that, all were negative. Besides, Iranian imipenem and cefepime disks have had distinguishable difference in susceptibility of isolates.Conclusion: Fortunately, none of gram negative isolates were MBL producer, which revealed no colonization of MBL producing bacteria. Iranian-made disks appear efficient except for imipenem and cefepime.

  8. Feasibility of using microbeads with holographic barcodes to track DNA specimens in the clinical molecular laboratory

    Directory of Open Access Journals (Sweden)

    Jason D. Merker

    2013-07-01

    Full Text Available We demonstrate the feasibility of using glass microbeads with a holographic barcode identifier to track DNA specimens in the molecular pathology laboratory. These beads can be added to peripheral blood specimens and are carried through automated DNA extraction protocols that use magnetic glass particles. We found that an adequate number of microbeads are consistently carried over during genomic DNA extraction to allow specimen identification, that the beads do not interfere with the performance of several different molecular assays, and that the beads and genomic DNA remain stable when stored together under regular storage conditions in the molecular pathology laboratory. The beads function as an internal, easily readable specimen barcode. This approach may be useful for identifying DNA specimens and reducing errors associated with molecular laboratory testing.

  9. Speciation and Biofilm Production of Coagulase Negative Staphylococcal Isolates from Clinically Significant Specimens and their Antibiogram

    Directory of Open Access Journals (Sweden)

    S. S. Vijayasri Badampudi

    2016-04-01

    Full Text Available Background: Coagulase Negative Staphylococci (CONS are increasingly recognized as significant nosocomial pathogens. Their ability of biofilm formation and multiple drug resistance are causing serious human infections. Aim and Objectives: To isolate, identify, speciate clinically significant CONS from various specimens, to study antibiotic resistance pattern and biofilm production. Material and Methods: Specimens were collected aseptically, processed and identified upto the species level by a simple scheme of tests urease, novobiocin resistance, mannose and mannitol fermentation, ornithine decarboxylase. Antibiotic sensitivity was done with special reference to methicillin resistance. Biofilm formation was detected by Congo Red Agar (CRA method and Tube Method (TM. Results: Study groupOf 100 isolates majority were pus (40, followed by urine (28, blood (16, CSF (5, body fluids (4 and catheter tips and implants (7. The most common species isolated was S. epidermidis (40% followed by S. haemolyticus (26%, S. saprophyticus (15%, S. schleiferi (13%, S. simulans (2%, S. cohnii (2% and S. warneri and S. capitis each 1%. Resistance to penicillin was 91% followed by ampicillin (79%, cotrimoxazole (67%. Methicillin resistance was 72%. Biofilm producers were 69% by CRAmethod and 33% by TM with majority species S. epidermidis (82.5%- CRA and 55%-TM. Biofilm production was significantly associated with MRCONS (p value 0.0036. Control group-Of 30 isolates were S. epidermidis 66.6% followed by S. haemolyticus (16.66%. Biofilm producers were 53.33% by CRA method and 26.65% by TM with majority species S. epidermidis (65%-CRA and 30%-TM.Methicillin resistance was 26.6%. Conclusion: Clinical significance of CONS is increasing day by day, so there is a need for accurate identification to species level and their antibiogram to avoid multidrug resistance. Biofilm producing CONS species pose a risk and CRA method for screening biofilm can be used in all conventional

  10. Improving the transport of urgent specimens to an off-site laboratory using a novel sticker-tracker.

    Science.gov (United States)

    Sepahzad, Afsoon; Ejiofor, Florence; Giles, Susan; Klaber, Robert

    2013-01-01

    Obtaining results for urgent microbiology specimens in an efficient manner is imperative to ensure that patients receive appropriate antibiotic therapy. A previous audit carried out in the Paediatric department of a central teaching hospital and a number of clinical incidents, highlighted a delay in transport of specimens (exceeding eight hours) and 'missing' specimens. This results in empirical antibiotic treatment of infection, with delay in confirming microbiology result and unnecessary, distressing repeat investigation. As an initial step we sought staff opinion to further explore the problem. A sticker was designed for the microbiology specimen bag to assign accountability, track each step in the transport process and to raise awareness of the problem. The sticker required the member of staff responsible at each stage of the process to time, date and sign it, to allow tracking of potential delays. The new sticker tracking system was promoted and launched in the Paediatric department. Initial challenges included lack of awareness of the protocol and lack of pods for sending urgent specimens. The team met regularly and completed stickers were analysed weekly to identify on-going issues and to devise solutions. Consequently total transport time was reduced to an average of 69 minutes by September (within four hr target). Our intervention improved the efficiency and reliability of urgent specimen transport. This is likely to result in safer antibiotic use and avoid the need for repeat investigation. The system is now also used in the Neonatal department and has lead to the development of a new 'Central Specimens Reception'.

  11. Clinical value of renal images obtained incidentally to bone scintigraphy

    International Nuclear Information System (INIS)

    Ohishi, Y.; Machida, T.; Miki, M.; Kido, A.; Tanaka, A.

    1982-01-01

    Various studies were made on 400 renal (including 325 clinical cases) observed during whole-body bone scintigraphy using 99mTc-MDP. Asymmetrical renal images in bone scintigrams were obtained from 40% of the urologic patients and 7.5% of the nonurologic patients. Out of the asymmetrical images of the urologic patients, 50% provided nonvisualized kidneys and 35% showed unilateral renal high accumulation. It can be said from the above that renal images incidentally obtained during whole-body bone scintigraphy should not be overlooked

  12. Examination of the fatigue life under combined loading of specimens

    Directory of Open Access Journals (Sweden)

    Fojtík F.

    2008-11-01

    Full Text Available This contribution describes experimental results under combined loading of specimens manufactured from common construction steel 11523. Specimens were gradually loaded by amplitude of the torque, then by combination of torque and tension prestress. The last set of specimens was loaded in combination of torque and inner overpressure. To obtain the required input values the stress-strain analysis of specimens by finite element method in software Ansys was performed within the last experiment. For evaluation of the results the Fuxa's criterion was applied. The performed experiments and their results embody a good agreement with bellow mentioned conjugated strength criterion. The experiments were performed on reconstructed testing machine equipped by pressure chamber.

  13. Museum genomics: low-cost and high-accuracy genetic data from historical specimens.

    Science.gov (United States)

    Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C

    2011-11-01

    Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.

  14. Role of specimen size upon the measured toughness of cellular solids

    International Nuclear Information System (INIS)

    Christodoulou, I; Tan, P J

    2013-01-01

    It is well known that the mechanical properties of cellular solids depend critically upon the specimen size and that a 'sufficiently' large test specimen is needed to obtain representative bulk values. Notwithstanding, the fracture toughness of cellular solids is still measured experimentally based on standards, such as the ASTM E399 and E813, developed for solid materials that do not possess an intermediate, 'cell-level' length scale. Experimental data in the literature appears to show that the toughness of stochastic 3D foams is, also, size-dependent. This paper presents the results of a detailed finite element (FE) study that will quantify, and identify the physical origin of, the size-dependent effect. Three-point bending of a single-edge notched (or SEN(B)) specimen, with a 2D Voronoi micro-architecture, is modelled numerically to obtain estimates of fracture toughness which are compared to those obtained with a 'boundary-layer' analysis

  15. Clinical map document based on XML (cMDX: document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens

    Directory of Open Access Journals (Sweden)

    Bettendorf Olaf

    2010-11-01

    Full Text Available Abstract Background The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa. The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. Methods The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension with the textual data (e.g. histological patterns. The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. Results The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25. 54% of PCa showed a multifocal growth pattern. Conclusions cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis.

  16. A Real-Time PCR Assay to Identify and Discriminate Among Wild-Type and Vaccine Strains of Varicella-Zoster Virus and Herpes Simplex Virus in Clinical Specimens, and Comparison With the Clinical Diagnoses

    Science.gov (United States)

    Harbecke, Ruth; Oxman, Michael N.; Arnold, Beth A.; Ip, Charlotte; Johnson, Gary R.; Levin, Myron J.; Gelb, Lawrence D.; Schmader, Kenneth E.; Straus, Stephen E.; Wang, Hui; Wright, Peter F.; Pachucki, Constance T.; Gershon, Anne A.; Arbeit, Robert D.; Davis, Larry E.; Simberkoff, Michael S.; Weinberg, Adriana; Williams, Heather M.; Cheney, Carol; Petrukhin, Luba; Abraham, Katalin G.; Shaw, Alan; Manoff, Susan; Antonello, Joseph M.; Green, Tina; Wang, Yue; Tan, Charles; Keller, Paul M.

    2014-01-01

    A real-time PCR assay was developed to identify varicella-zoster virus (VZV) and herpes simplex virus (HSV) DNA in clinical specimens from subjects with suspected herpes zoster (HZ; shingles). Three sets of primers and probes were used in separate PCR reactions to detect and discriminate among wild-type VZV (VZV-WT), Oka vaccine strain VZV (VZV-Oka), and HSV DNA, and the reaction for each virus DNA was multiplexed with primers and probe specific for the human β-globin gene to assess specimen adequacy. Discrimination of all VZV-WT strains, including Japanese isolates and the Oka parent strain, from VZV-Oka was based upon a single nucleotide polymorphism at position 106262 in ORF 62, resulting in preferential amplification by the homologous primer pair. The assay was highly sensitive and specific for the target virus DNA, and no cross-reactions were detected with any other infectious agent. With the PCR assay as the gold standard, the sensitivity of virus culture was 53% for VZV and 77% for HSV. There was 92% agreement between the clinical diagnosis of HZ by the Clinical Evaluation Committee and the PCR assay results. PMID:19475609

  17. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  18. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  19. A Comparative Study of the Retentive Strengths of Commercial and Indigenously Developed Luting Cements using Both Lathe-cut and Clinically Simulated Specimens.

    Science.gov (United States)

    Mathew, Joe; Kurian, Byju P; Philip, Biju; Mohammed, Sunil; Menon, Preetha; Raj, Rajan S

    2016-08-01

    Superior adhesive strength in luting agents is of paramount significance in fixed partial denture success. In this in vitro study five cements were tested for retentive qualities, using both lathe-cut and hand-prepared specimens. A total of 104 freshly extracted tooth specimens were prepared. Seventy of them were lathe-cut and 30 specimens were hand-prepared to simulate clinical conditions. Five different cements were tested, which included a compomer, a composite, a zinc phosphate, and 2 glass-ionomer luting cements. Of the 5, 2 trial cements were indigenously developed by Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum, India - a glass-ionomer cement (Chitra GIC) and a chemical-cure composite (Chitra CCC). All cements were compared within each group and between groups (lathe-prepared and hand-prepared). GC Fuji 1 (GC America) exhibited superior retentive strengths in both lathe-cut and hand-prepared specimens, whereas the compomer cement displayed the lowest values when tested. In lathe-cut specimens, statistical analysis showed no significant difference between GC Fuji 1 and indigenously developed Chitra CCC. Both Chitra CCC and GC Fuji 1 have comparable strengths in lathe-cut samples, making Chitra CCC a potential luting agent. Statistical analysis reveals that all cements, except GC Fuji 1, exhibited a significant decrease in strength due to the change in design uniformity. The chemical bonding of GC Fuji 1 proves to be quite strong irrespective of shape and precision of the tooth crown. The indigenously developed Chitra GIC and Chitra CCC showed promising results to be used as a potential luting agent.

  20. Compliance of clinical microbiology laboratories in the United States with current recommendations for processing respiratory tract specimens from patients with cystic fibrosis.

    Science.gov (United States)

    Zhou, Juyan; Garber, Elizabeth; Desai, Manisha; Saiman, Lisa

    2006-04-01

    Respiratory tract specimens from patients with cystic fibrosis (CF) require unique processing by clinical microbiology laboratories to ensure detection of all potential pathogens. The present study sought to determine the compliance of microbiology laboratories in the United States with recently published recommendations for CF respiratory specimens. Microbiology laboratory protocols from 150 of 190 (79%) CF care sites were reviewed. Most described the use of selective media for Burkholderia cepacia complex (99%), Staphylococcus aureus (82%), and Haemophilus influenzae (89%) and identified the species of all gram-negative bacilli (87%). Only 52% delineated the use of agar diffusion assays for susceptibility testing of Pseudomonas aeruginosa. Standardizing laboratory practices will improve treatment, infection control, and our understanding of the changing epidemiology of CF microbiology.

  1. The effect of specimen and flaw dimensions on fracture toughness

    International Nuclear Information System (INIS)

    Nevalainen, M.J.

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account

  2. Final Report: Posttest Analysis of Omega II Optical Specimens

    International Nuclear Information System (INIS)

    Newlander, C D; Fisher, J H

    2007-01-01

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silica substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data

  3. A mechanical microcompressor for high resolution imaging of motile specimens.

    Science.gov (United States)

    Zinskie, Jessica A; Shribak, Michael; Bruist, Michael F; Aufderheide, Karl J; Janetopoulos, Chris

    2015-10-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differential interference contrast (DIC) microscopy, orientation-independent (OI) DIC, and real-time birefringence imaging using a video-enhanced polychromatic polscope. We also describe an enhancement of our previous design by engineering a new device where the coverslip mount is fashioned onto the top of the base; so the entire apparatus is accessible on top of the stage. The new location allows for easier manipulation of the mount when compressing or releasing a specimen on an inverted microscope. Using this improved design, we imaged immobilized bacteria, yeast, paramecia, and nematode worms and obtained an unprecedented view of cell and specimen details. A variety of microscopic techniques were used to obtain high resolution images of static and dynamic cellular and physiological events. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    International Nuclear Information System (INIS)

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  5. Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

    Directory of Open Access Journals (Sweden)

    Tibor Mezei

    Full Text Available Fine needle aspiration (FNA cytology is a well-established diagnostic method based on the microscopic interpretation of often scant cytological material; therefore, experience, good technique and smear quality are equally important in obtaining satisfactory results.We studied the use of fresh surgical pathology specimens for making so-called mock-FNA smears with the potential of cytohistological correlation. Additionally, we studied how this process aids the improvement of preparation technique and smear quality.Cytological aspirates from 32 fresh biopsy specimens from various sites: lung (20, lymph nodes (6, and breast (6 were obtained, all with a clinical diagnosis of tumor. Aspiration was performed from grossly palpable tumors. 25 G needle and Cameco-type syringe holder was used with minimal or no suction.Unfixed surgical specimens provided sufficient cytological material that resulted in good quality smears. After standard processing of specimens into microscopic sections from paraffin embedded tissues, cytohistological case-series were created. No significant alteration was reported in tissue architecture on hematoxylin-eosin stained sections after the aspiration procedure. A gradual, but steady improvement was observed in smear quality just after a few preparations.Our study proved that surgical specimens may be used as a source of cytological material to create cytohistological correlation studies and also to improve FNA cytology skills. The use of very fine gauge needle (25 G, 0,6 mm diameter during the sampling process does not alter tissue architecture therefore the final histopathological diagnosis is not compromised. We conclude that by using fresh surgical specimens useful cytohistological collections can be created both as a teaching resource and as improving experience.

  6. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  7. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  8. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    International Nuclear Information System (INIS)

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations

  9. JR-curves of wide plates and CT25 specimens

    International Nuclear Information System (INIS)

    Aurich, D.; Wobst, K.; Krafka, H.

    1987-01-01

    In connection with the problem of the applicability of the characteristic specimen date - i.e. the initiation and stable crack propagation under maximal loads, together with the elastic-plastic material behaviour - to that of actual components, spot-check type beside tests were conducted using wide-plate central crack, central notch (CCT, CNT) and double external crack (DECT) samples. The material in question was an StE 460 steel. A comparison between the determined values shows that the assessed pressure vessel behaviour differs extensively to the values derived from the CCT and CNT specimens. The corresponding results obtained from the CT25 and DECT specimens vary only slightly in the region of interest and correspond to real vessel values. (orig./DG) [de

  10. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  11. Face compression yield strength of the copper-Inconel composite specimen

    International Nuclear Information System (INIS)

    Horie, T.

    1987-05-01

    A new equation for the face compression yield strength of copper-Inconel composite material has been derived. Elastic-plastic finite element analyses were also made for composite specimens with various aspect ratios to examine the edge effect of the specimen. According to the results of both the new equation and the analyses, the face compression yield strength of the composite should be decreased by about 25% from the value obtained with Becker's equation

  12. CGH and SNP array using DNA extracted from fixed cytogenetic preparations and long-term refrigerated bone marrow specimens

    Directory of Open Access Journals (Sweden)

    MacKinnon Ruth N

    2012-02-01

    Full Text Available Abstract Background The analysis of nucleic acids is limited by the availability of archival specimens and the quality and amount of the extracted material. Archived cytogenetic preparations are stored in many laboratories and are a potential source of total genomic DNA for array karyotyping and other applications. Array CGH using DNA from fixed cytogenetic preparations has been described, but it is not known whether it can be used for SNP arrays. Diagnostic bone marrow specimens taken during the assessment of hematological malignancies are also a potential source of DNA, but it is generally assumed that DNA must be extracted, or the specimen frozen, within a day or two of collection, to obtain DNA suitable for further analysis. We have assessed DNA extracted from these materials for both SNP array and array CGH. Results We show that both SNP array and array CGH can be performed on genomic DNA extracted from cytogenetic specimens stored in Carnoy's fixative, and from bone marrow which has been stored unfrozen, at 4°C, for at least 36 days. We describe a procedure for extracting a usable concentration of total genomic DNA from cytogenetic suspensions of low cellularity. Conclusions The ability to use these archival specimens for DNA-based analysis increases the potential for retrospective genetic analysis of clinical specimens. Fixed cytogenetic preparations and long-term refrigerated bone marrow both provide DNA suitable for array karyotyping, and may be suitable for a wider range of analytical procedures.

  13. Molecular detection of candida species from hospitalized patient’s specimens.

    Science.gov (United States)

    Camacho-Cardoso, José Luis; Martínez-Rivera, María Ángeles; Manzano-Gayosso, Patricia; Méndez-Tovar, Luis Javier; López-Martínez, Rubén; Hernández-Hernández, Francisca

    To identify the most frequent Candida species in specimens from patients hospitalized in different medical centers of Mexico City, with suspected fungal infection. Specimens were grown on Sabouraud dextrose agar at 28°C for 72 h. In addition, DNA was extracted. Isolates were grown on CHROMagar Candida™, at 37°C for 48 h. The molecular identification was performed by polymerase chain reaction (PCR) using primers specific for four species. Eighty one specimens were processed and included: bronchial lavage, pleural, cerebrospinal, peritoneal, ascites and bile fluids; blood, sputum, bone marrow, oro-tracheal cannula and ganglion. By culture, 30 samples (37%) were positive, and by PCR, 41 (50.6%). By PCR, the frequency of species was: Candida albicans 82.9%, Candida tropicalis 31.7%, Candida glabrata 24.4%, and Candida parapsilosis 4.9%. In 34.1% of specimens a species mixture was detected suggesting a co-infection: Two species in five specimens (C. albicans-C tropicalis and C. albicans-C glabrata), and three species in three specimens (C. albicans-C. glabrata-C. tropicalis). The PCR is an useful tool for detection the most common Candida species causing infection in hospitalized patients, it avoids the requirement of culture weather we start from clinical specimen and it favors the early diagnosis of invasive candidiasis. Copyright: © 2017 SecretarÍa de Salud

  14. Rotating specimen rack repair

    International Nuclear Information System (INIS)

    Miller, G.E.; Rogers, P.J.; Nabor, W.G.; Bair, H.

    1984-01-01

    In 1980, an operator at the UCI TRIGA Reactor noticed difficulties with the rotation of the specimen rack. Investigations showed that the drive bearing in the rack had failed and allowed the bearings to enter the rack. After some time of operation in static mode it was decided that installation of a bearing substitute - a graphite sleeve - would be undertaken. Procedures were written and approved for removal of the rack, fabrication and installation of the sleeve, and re-installation of the rack. This paper describes these procedures in some detail. Detailed drawings of the necessary parts may be obtained from the authors

  15. Rotary powered device for bone marrow aspiration and biopsy yields excellent specimens quickly and efficiently.

    Science.gov (United States)

    Swords, Ronan T; Kelly, Kevin R; Cohen, Stephen C; Miller, Larry J; Philbeck, Thomas E; Hacker, Sander O; Spadaccini, Cathy J; Giles, Francis J; Brenner, Andrew J

    2010-06-01

    Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. A pre-clinical evaluation of the device (OnControl, Vidacare Corporation, San Antonio, TX, USA) on anesthetized pigs was conducted, in addition to a clinical evaluation in hematology clinic patients requiring a bone marrow biopsy. Twenty-six samples were collected from the swine model. No cellular artifact or thermal damage was reported in any of the samples obtained. For the clinical evaluation of the device, 16 patients were recruited. Mean time from needle contact with skin to needle removal was 38.5 +/- 13.94 seconds. No complications were reported. In this study, the manual and powered samples were equivalent in specimen quality. In the patients evaluated, the device was safe, easy to use and the mean procedural time was significantly faster than previously reported with a manual technique.

  16. An analysis of forensic entomological specimens by Universiti Kebangsaan Malaysia.

    Science.gov (United States)

    Syamsa, R A; Ahmad, F M S; Marwi, M A; Zuha, R M; Omar, B

    2010-09-01

    This study reviews forensic entomological specimens analysed by the Department of Parasitology & Medical Entomology, Universiti Kebangsaan Malaysia for the year 2004. A total of 10 cases (6 males and 4 females) were observed for the entomological specimens. Various types of death scenes were obtained including indoor and outdoor area such as bushes field, rubbish dumping site, and aquatic areas. Identified fly species collected from the death sites were blow flies, Chrysomya megacephala, Chrysomya rufifacies and Lucilia cuprina and unknown sarcophagid larvae, with Ch. megacephala being the most common species found in the ecologically varied death scene habitats. The post-mortem interval (PMI) estimation ranged from one to five days, based on the entomological specimens collected.

  17. The effect of specimen and flaw dimensions on fracture toughness

    Energy Technology Data Exchange (ETDEWEB)

    Nevalainen, M.J. [VTT Manufacturing Technology, Espoo (Finland)

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account. 64 refs. The thesis includes also four previous publications by author.

  18. Cerenkov and radioluminescence imaging of brain tumor specimens during neurosurgery

    Science.gov (United States)

    Spinelli, Antonello Enrico; Schiariti, Marco P.; Grana, Chiara M.; Ferrari, Mahila; Cremonesi, Marta; Boschi, Federico

    2016-05-01

    We presented the first example of Cerenkov luminescence imaging (CLI) and radioluminescence imaging (RLI) of human tumor specimens. A patient with a brain meningioma localized in the left parietal region was injected with 166 MBq of Y90-DOTATOC the day before neurosurgery. The specimens of the tumor removed during surgery were imaged using both CLI and RLI using an optical imager prototype developed in our laboratory. The system is based on a cooled electron multiplied charge coupled device coupled with an f/0.95 17-mm C-mount lens. We showed for the first time the possibility of obtaining CLI and RLI images of fresh human brain tumor specimens removed during neurosurgery.

  19. Prediction of mass absorption coefficients from inelastically scattered X-radiation for specimens of less than 'infinite thickness'

    International Nuclear Information System (INIS)

    Kieser, R.; Mulligan, T.J.

    1979-01-01

    An equation is developed which describes the X-ray scatter radiation from specimens of any thickness. This equation suggests that a specimen's mass absorption coefficient can be determined from its inelastically scattered X-radiation not only when the specimen is 'infinitely thick' but also when it is of 'intermediate thickness'. Measurements have been carried out with a standard energy-dispersive X-ray spectrometer on specimens of 'intermediate thickness'. Good agreement is obtained between the mass absorption coefficients that are calculated from the scattered radiation and those obtained on the basis of tabulated mass absorption coefficients for the elements. (author)

  20. How useful are delta checks in the 21st century? A stochastic-dynamic model of specimen mix-up and detection

    Directory of Open Access Journals (Sweden)

    Katie Ovens

    2012-01-01

    Full Text Available Introduction: Delta checks use two specimen test results taken in succession in order to detect test result changes greater than expected physiological variation. One of the most common and serious errors detected by delta checks is specimen mix-up errors. The positive and negative predictive values of delta checks for detecting specimen mix-up errors, however, are largely unknown. Materials and Methods: We addressed this question by first constructing a stochastic dynamic model using repeat test values for five analytes from approximately 8000 inpatients in Calgary, Alberta, Canada. The analytes examined were sodium, potassium, chloride, bicarbonate, and creatinine. The model simulated specimen mix-up errors by randomly switching a set number of pairs of second test results. Sensitivities and specificities were then calculated for each analyte for six combinations of delta check equations and cut-off values from the published literature. Results: Delta check specificities obtained from this model ranged from 50% to 99%; however the sensitivities were generally below 20% with the exception of creatinine for which the best performing delta check had a sensitivity of 82.8%. Within a plausible incidence range of specimen mix-ups the positive predictive values of even the best performing delta check equation and analyte became negligible. Conclusion: This finding casts doubt on the ongoing clinical utility of delta checks in the setting of low rates of specimen mix-ups.

  1. Pathologic diagnoses of appendectomy specimens: a 10-year review.

    African Journals Online (AJOL)

    A retrospective study was performed to see the pattern of histopathologic diagnoses in appendectomy specimens, their demographics, and the rate of negative appendectomy. Materials and methods: Records of resected appendices with a clinical diagnosis of acute appendicitis submitted to histopathology department of ...

  2. Antibiotic Resistance Profiling of Staphylococcus aureus Isolated from Clinical Specimens in a Tertiary Hospital from 2010 to 2012

    Directory of Open Access Journals (Sweden)

    Alain C. Juayang

    2014-01-01

    Full Text Available MRSA infection can affect a wide array of individuals that may lead to treatment failure. Also, the infection has the potential to spread from one area to another particularly health care facilities or communities eventually causing minor outbreaks. With this premise, the study aimed to describe MRSA infections using the hospital-based data of a tertiary hospital in Bacolod City, Philippines, from 2010 to 2012. Specifically, this study aimed to evaluate the antimicrobial resistance of S. aureus isolated from clinical specimens and to put emphasis on the prevalence of MRSA and Inducible Clindamycin Resistance. A total of 94 cases from 2010 to 2012 were diagnosed to have S. aureus infection using conventional bacteriologic methods. From these cases, 38 (40.6% were identified as MRSA and 37 (39.4% were inducible clindamycin resistant. Wounds and abscesses were considered to be the most common specimens with MRSA infections having 71.05% while blood was the least with 5.3%. For drug susceptibility, out of the 94 S. aureus cases, including MRSA, 100% were susceptible to linezolid making it the drug of choice for this study. It was then followed by tetracycline having a mean susceptibility of 95%;, while penicillin G was ineffective with 94 cases having 0% susceptibility.

  3. Preparation of TEM specimen by cross-section technique

    International Nuclear Information System (INIS)

    Hamada, Shozo

    1986-01-01

    Transmission electron microscopy (TEM) is applied to the direct observation of the depth dependent damage structure in ion-irradiated stainless steel by using the cross-section technique; obtaining the TEM specimen from a slice of the irradiated stainless steel with thick Ni plating. Here has been developed the specimen preparation method of cross-section technique without heat treatment, which was necessary in the conventional method to strengthen the bonding between Ni and stainless steel. Nickel plating with good bonding to stainless steel is enabled by the following manner. First, the irradiated stainless steel is immersed in the Wood's nickel solution at room temperature for 60s to activate the surface, followed by the stricking for 300s at a current density of 300 A/m 2 in the solution to make fine and homogeneous nucleation of Ni on the stainless steel. Then, the sample is plated with Ni in the Watt's nickel plating solution at 333 K with current density of 900 ∼ 1,000 A/m 2 . The TEM disc is obtained by mechanical slicing from the specimen with Ni plating of more than 3 mm thickness. Electropolishing is accomplished by using both Ballmann method and jet electropolishing to perforate the disc accurately at the aimed point for the observation of the damage structure. (author)

  4. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  5. Testing machine for fatigue crack kinetic investigation in specimens under bending

    International Nuclear Information System (INIS)

    Panasyuk, V.V.; Ratych, L.V.; Dmytrakh, I.N.

    1978-01-01

    A kinematic diagram of testing mashine for the investigation of fatigue crack kinetics in prismatic specimens, subjected to pure bending is described. Suggested is a technique of choosing an optimum ratio of the parameters of ''the testing machine-specimen'' system, which provide the stabilization of the stress intensity coefficient for a certain region of crack development under hard loading. On the example of the 40KhS and 15Kh2MFA steel specimens the pliability of the machine constructed according to the described diagram and designed for the 30ONxm maximum bending moment. The results obtained can be used in designing of the testing machines for studying pure bending under hard loading and in choosing the sizes of specimens with rectangular cross sections for investigations into the kinetics of the fatigue crack

  6. Evaluation of the ARCHITECT urine NGAL assay: Assay performance, specimen handling requirements and biological variability

    NARCIS (Netherlands)

    Grenier, F.C.; Ali, S.; Syed, H.; Workman, R.; Martens, F.; Liao, M.; Wang, Y.; Wong, P.Y.

    2010-01-01

    Objectives: NGAL (Neutrophil Gelatinase-Associated Lipocalin) has emerged as a new biomarker for the identification of acute kidney injury. Reliable clinical evaluations require a simple, robust test method for NGAL, and knowledge of specimen handling and specimen stability characteristics. We

  7. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Science.gov (United States)

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  8. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  9. Specimen Identification Errors in Breast Biopsies: Age Matters. Report of Two Near-Miss Events and Review of the Literature.

    Science.gov (United States)

    Tozbikian, Gary; Gemignani, Mary L; Brogi, Edi

    2017-09-01

    The consequences of patient identification errors due to specimen mislabeling can be deleterious. We describe two near-miss events involving mislabeled breast specimens from two patients who sought treatment at our institution. In both cases, microscopic review of the slides identified inconsistencies between the histologic findings and patient age, unveiling specimen identification errors. By correlating the clinical information with the microscopic findings, we identified mistakes that had occurred at the time of specimen accessioning at the original laboratories. In both cases, thanks to a timely reassignment of the specimens, the patients suffered no harm. These cases highlight the importance of routine clinical and pathologic correlation as a critical component of quality assurance and patient safety. A review of possible specimen identification errors in the anatomic pathology setting is presented. © 2017 Wiley Periodicals, Inc.

  10. Contribution of flow cytometry to the diagnosis of gastric lymphomas in endoscopic biopsy specimens.

    Science.gov (United States)

    Almasri, N M; Zaer, F S; Iturraspe, J A; Braylan, R C

    1997-07-01

    Gastric lymphomas seem to have unique clinical, pathologic, and immunophenotypic features that set them apart from nodal lymphomas. Microscopic examination of endoscopic biopsy specimens is the most frequent procedure used to diagnose gastric tumors, but it is very difficult, and sometimes impossible, to recognize lymphomas in endoscopic samples by histologic or even immunohistologic methods. Because most gastric lymphomas are of B-cell origin, we used flow cytometry to assess B-cell clonality in gastric biopsy specimens containing dense lymphocytic infiltrates thought to represent lymphoma. We prepared viable cell suspensions from unfixed specimens obtained from 29 consecutive patients who had a previous microscopic diagnosis of suspicious gastric lymphoid infiltrates. We performed immunophenotypic studies with multicolor flow cytometry, and we assessed clonality by examination of immunoglobulin (Ig) light-chain expression analyzed exclusively on B cells identified by anti-CD20 or CD19 antibodies. The mean number of cells recovered was 1.04 x 10(6), from an average of 5.5 gastric biopsy fragments per patient. In 26 of the 29 patients, the number of cells was adequate for analysis. We detected B-cell monoclonality in 16 cases, including 5 in which the percentage of clonal B cells was less than 5%. Of the 16 cases, only 8 could be diagnosed as lymphomas on morphologic grounds alone; the remaining 8 patients had either suspicious lymphoid infiltrates or chronic gastritis. The three cases with an insufficient number of cells were considered non-neoplastic either on histologic grounds alone or in conjunction with Southern analysis of Ig genes. We conclude that flow cytometric immunophenotypic analysis of freshly prepared cell suspensions obtained from endoscopic biopsy specimens can be used to evaluate gastric lymphocytic infiltrates. Specifically, the analysis of surface Ig light-chain expression on B cells distinguishes between monoclonal (lymphoma) and polyclonal

  11. Culturing Stool Specimens for Campylobacter spp., Pennsylvania, USA

    Science.gov (United States)

    M’ikanatha, Nkuchia M.; Dettinger, Lisa A.; Perry, Amanda; Rogers, Paul; Reynolds, Stanley M.

    2012-01-01

    In 2010, we surveyed 176 clinical laboratories in Pennsylvania regarding stool specimen testing practices for enteropathogens, including Campylobacter spp. Most (96.3%) routinely test for Campylobacter spp. In 17 (15.7%), a stool antigen test is the sole method for diagnosis. We recommend that laboratory practice guidelines for Campylobacter spp. testing be developed. PMID:22377086

  12. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  13. Measurement of deformation field in CT specimen using laser speckle

    International Nuclear Information System (INIS)

    Jeon, Moon Chang; Kang, Ki Ju

    2001-01-01

    To obtain A 2 experimentally in the J-A 2 theory, deformation field on the lateral surface of a CT specimen was to be determined using laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure A 2 continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and A 2 were explored

  14. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.; Maslehuddin, M.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.

    2010-01-01

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the γ-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring γ-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  15. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-04-15

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the {gamma}-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring {gamma}-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  16. Relationship between strain and central deflection in small punch creep specimens

    International Nuclear Information System (INIS)

    Yang Zhen; Wang Zhiwen

    2003-01-01

    Acquiring information about creep strain directly from small punch creep tests is difficult because the deformation behaviour of the small punch specimen is complicated. A routine is suggested in the present paper to treat this problem indirectly. Based on a finite element analysis, it is proposed that the relationship of central deflection δ to central creep strain ε c of a specimen subjected to creep can be represented approximately by the relationship of central deflection δ to central (elastic-plastic) strain ε of a specimen not subjected to creep. With this hypothesis, the δ∼ε c relation of the small punch creep specimen is obtained by resorting to a rigid-plastic membrane stretch forming model. Finally, small punch creep test results are used to evaluate creep strain and creep strain rate by taking advantage of this δ∼ε c relation

  17. The frequency of Listeria monocytogenes strains recovered from clinical and non-clinical samples using phenotypic methods and confirmed by PCR

    Directory of Open Access Journals (Sweden)

    abazar pournajaf

    2013-09-01

    Full Text Available Background: Listeria monocytogenes is a facultative intracellular pathogen that causes listeriosis which has extensive clinical manifestations. Infections with L. monocytogenes are a serious threat to immunocompromised persons. The aim of this study was to determine the frequency of L. monocytogenes strains recovered from clinical and non-clinical samples using phenotypic methods and confirmed by PCR. Materials and Methods: In this study, 617 specimens were analyzed. All specimens were cultured in the specific PALCAM agar. Colonies were initially identified by routine biochemical tests. Finally, PCR assays using primers specific for inlA gene were performed. Results: In all, 46 (8.2% L. monocytogenes isolates were recovered from 617 specimens. Fourteen (8.2% strains, including 4 (7.5%, 2 (5.7%, 5 (14.2% and 3 (8.5% isolates were obtained from placental tissue, urine, vaginal and rectal swabs, respectively. In addition, 9 (7.4% strains of L. monocytogenes which were isolated from 107 different dairy products originated from cheese 5 (7.1%, cream 2 (10% and kashk 2 (11.7%, respectively. Among 11 (5.2% strains isolated from 210 different meat products, 5 (5.5%, 4 (7.2% and 2 (3% strains belonged to sausage, meat and poultry extracts, respectively. Finally, 12 (9.2% Listeria strains were recovered from 130 animal specimens that included 6 (10%, 4 (8% and 2 (10% strains from goat, sheep and cattle, respectively. Furthermore, all Listeria isolates (100% were found to be carriers of  inlA gene in PCR assay. Conclusion: The present study showed that the clinical and non-clinical specimens were contaminated with L. monocytogenes. So, it seems necessary to use a simple and standard technique such as PCR for rapid detection of this organism from various sources.

  18. Transmission electron microscopy of bulk specimens over 10 µm in thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sadamatsu, Sunao, E-mail: sadamatsu@mech.kagoshima-u.ac.jp [Department of Mechanical Engineering, Kagoshima University, Korimoto, Kagoshima 890-0065 (Japan); Tanaka, Masaki; Higashida, Kenji [Department of Materials Science and Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Matsumura, Syo [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Ultramicroscopy Research Center, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-03-15

    We succeeded the observation of microstructures in bulk-sized specimens of over 10 µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10 µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. - Highlights: • We developed a method which enables thick specimens to be observed using EF-TEM. • The effects of energy filter width and position on images were determined. • We suggested a method to determine the thickness of a thick film sample. • We achieved observation of microstructures in specimens with a thickness of 10 µm.

  19. Thermal analysis on the specimens for low irradiation temperature below 100degC in the HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Kim, Bong-Goo; Lee, Byung-Chul; Kim, Tae-Kyu [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2012-03-15

    A capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. As a part of the research reactor development project with a plate type fuel, the irradiation tests of beryllium, zircaloy-4 and graphite materials using the capsule will be carried out to obtain the mechanical characteristics at low temperatures below 100degC with 30 MW reactor power. In this study, in order to obtain the preliminary design data of the capsule with various specimens and the temperature of specimens, a thermal analysis is performed by using an ANSYS program. The finite element models for the cross section of the capsule containing the specimen are generated, and the temperatures are evaluated. The analysis results show that most specimens meet the irradiation target temperature. However, some canned graphite specimens have a slightly high temperature, and the gap size has a significant effect on the specimen temperature. Based on those results a detailed design and analysis of the capsule will be completed this year. (author)

  20. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    Science.gov (United States)

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  1. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  2. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  3. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  4. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  5. Next-generation sampling: Pairing genomics with herbarium specimens provides species-level signal in Solidago (Asteraceae).

    Science.gov (United States)

    Beck, James B; Semple, John C

    2015-06-01

    The ability to conduct species delimitation and phylogeny reconstruction with genomic data sets obtained exclusively from herbarium specimens would rapidly enhance our knowledge of large, taxonomically contentious plant genera. In this study, the utility of genotyping by sequencing is assessed in the notoriously difficult genus Solidago (Asteraceae) by attempting to obtain an informative single-nucleotide polymorphism data set from a set of specimens collected between 1970 and 2010. Reduced representation libraries were prepared and Illumina-sequenced from 95 Solidago herbarium specimen DNAs, and resulting reads were processed with the nonreference Universal Network-Enabled Analysis Kit (UNEAK) pipeline. Multidimensional clustering was used to assess the correspondence between genetic groups and morphologically defined species. Library construction and sequencing were successful in 93 of 95 samples. The UNEAK pipeline identified 8470 single-nucleotide polymorphisms, and a filtered data set was analyzed for each of three Solidago subsections. Although results varied, clustering identified genomic groups that often corresponded to currently recognized species or groups of closely related species. These results suggest that genotyping by sequencing is broadly applicable to DNAs obtained from herbarium specimens. The data obtained and their biological signal suggest that pairing genomics with large-scale herbarium sampling is a promising strategy in species-rich plant groups.

  6. Detection of adenovirus in nasopharyngeal specimens by radioactive and nonradioactive DNA probes

    International Nuclear Information System (INIS)

    Hyypiae, T.

    1985-01-01

    The presence of adenovirus DNA in clinical specimens was analyzed by nucleic acid hybridization assays by both radioactive and enzymatic detection systems. The sensitivity of the hybridization tests was in the range of 10 to 100 pg of homologous adenovirus DNA. Minimal background was noticed with unrelated viral and nonviral DNA. Twenty-four nasopharyngeal mucus aspirate specimens, collected from children with acute respiratory infection, were assayed in the hybridization tests and also by an enzyme immunoassay for adenovirus hexon antigen which was used as a reference test. Sixteen specimens positive by the enzyme immunoassay also were positive in the two nucleic acid hybridization tests, and the remaining eight specimens were negative in all of the tests. The results indicate that nucleid acid hybridization tests with both radioactive and nonradioactive probes can be used for diagnosis of microbial infections

  7. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  8. Automated processing, extraction and detection of herpes simplex virus types 1 and 2: A comparative evaluation of three commercial platforms using clinical specimens.

    Science.gov (United States)

    Binnicker, Matthew J; Espy, Mark J; Duresko, Brian; Irish, Cole; Mandrekar, Jay

    2017-04-01

    Recently, automated platforms have been developed that can perform processing, extraction and testing for herpes simplex virus (HSV) nucleic acid on a single instrument. In this study, we compared three commercially-available systems; Aptima ® /Panther (Hologic, San Diego, CA), ARIES ® (Luminex Corporation, Austin, TX), and cobas ® 4800 (Roche Molecular Systems Inc, Pleasanton, CA) for the qualitative detection of HSV-1/2 in clinical samples. Two-hundred seventy-seven specimens (genital [n=193], dermal [n=84]) were submitted for routine HSV-1/2 real-time PCR by a laboratory developed test. Following routine testing, samples were also tested by the Aptima, ARIES, and cobas HSV-1/2 assays per the manufacturer's recommendations. Results were compared to a "consensus standard" defined as the result obtained from ≥3 of the 4 assays. Following testing of 277 specimens, the cobas and ARIES assays demonstrated a sensitivity of 100% for HSV-1 (61/61) and HSV-2 (55/55). The Aptima assays showed a sensitivity of 91.8% (56/61) for HSV-1 and 90.9% (50/55) for HSV-2. Percent specificities for HSV-1 were 96.2% (202/210) by cobas, 99.5% (209/210) by ARIES and 100% (236/236) by Aptima. For HSV-2, the specificities were 98.1% (211/215) by cobas, 99.5% (215/216) by ARIES and 100% (216/216) by Aptima. The turnaround time for testing 24 samples was 2.5h by the cobas 4800, 3.1h by Aptima/Panther, and 3.9h by ARIES. The three commercial systems can perform all current functions on a single platform, thereby improving workflow and potentially reducing errors associated with manual processing of samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    Science.gov (United States)

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  10. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  11. Development of Piezoelectric DNA-Based Biosensor for Direct Detection of Mycobacterium Tuberculosis in Clinical Specimens

    Directory of Open Access Journals (Sweden)

    Thongchai KAEWPHINIT

    2010-02-01

    Full Text Available This study was focused on establishment of piezoelectric biosensor for direct detection of Mycobacterium tuberculosis (MTB in clinical specimens. The quartz crystal immobilized via 3-mercaptopropionic acid (MPA/avidin/DNA biotinylated probe on gold surface and hybridization of the DNA target to DNA biotinylated probe. The optimal concentration of MPA, avidin and 5’-biotinylated DNA probe for immobilization of specific DNA probe on gold surface were 15 mM, 0.1 mg/ml and 1.5 μM, respectively. The detection of genomic DNA digestion in the range from 0.5 to 30 μg/ml. The fabricated biosensor was evaluated through an examination of 200 samples. No cross hybridization were observed against M. avium complex (MAC and other microorganism. This target DNA preparation without amplification will reduce time consuming, costs, and the tedious step of amplification. This study can be extended to develop the new method which is high sensitivity, specificity, cheap, easy to use, and rapid for detection of MTB in many fields.

  12. HMSRP Hawaiian Monk Seal Specimen Data (includes physical specimens, collection information, status, storage locations, and laboratory results associated with individual specimens)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes physical specimens, paper logs and Freezerworks database of all logged information on specimens collected from Hawaiian monk seals since 1975....

  13. Material Stress Fringe Constant Measurement of Specimen under Pure Bending Load by Use of Photoelastic Phase Shifting Method

    International Nuclear Information System (INIS)

    Liu, Guan Yong; Kim, Myung Soo; Baek, Tae Hyun

    2014-01-01

    In a photoelastic experiment, it is necessary to know the material stress fringe constant of the photoelastic specimen to determine the stresses from the measured isochromatic fringe orders. The material stress fringe constant can be obtained using a simple tension specimen and/or a circular disk under diametric compression. In these methods, there is generally a need to apply numerous loads to the specimen in response to the relationship of the fringe order. Then, the least squares method is used to obtain the material constant. In this paper, the fringe orders that appear on a four-point bending specimen are used to determine the fringe constant. This method requires four photoelastic fringes obtained from a circular polariscope by rotating the analyzer to 0, π/4, π/2, and 3π/4 radians. Using the four-point bending specimen to determine the material stress fringe constant has an advantage because measurements can be made at different locations by applying a constant load. The stress fringe constant measured with this method is within the range suggested by the manufacturer of the photoelastic material

  14. Significance of microscopic extention from 1162 esophageal carcinoma specimens

    International Nuclear Information System (INIS)

    Wang Jun; Zhu Shuchai; Han Chun; Zhang Xin; Xiao Aiqin; Ma Guoxin

    2007-01-01

    Objective: To examine the subclinical microscopic tumor extention along the long axis in 1162 specimens of esophageal carcinoma so as to help define the clinical target volume(CTV) according to the degree of microscopic extention(ME) for radiotherapy for esophageal carcinoma. Methods: 1162 resected esophageal carcinoma specimens originally located in the neck and thorax were studied with special reference to the correlation between upper and lower resection length from the tumor and positive microscopic margin. Another 52 resected esophageal carcinoma specimens were made into pathological giant sections: the actual resection length of upper and para-esophageal normal tissues was compared with that of the lower nor- mal tissues from the tumor, there by, the ratio of shrinkage was obtained and compared. Results: After fixation, microscopic positive margin ratio of the upper resection border in length ≤0.5 cm group was higher than that in length > 0.5 cm group (16.4% vs 4.1%, P=0.000). Microscopic positive margin ratio of the lower resection border in length ≤1.5 cm group was higher than that in length > 1.5 cm group( 8.1% vs 0.4%, P = 0.000). This showed that the positive margin ratio of the upper border was higher than that of the lower border in resection length > 1.5 cm group(3.5% vs 0.4%, P=0. 000). The actual length of upper and lower normal esophageal tissue after having been made into pathological giant sections in 52 patients, was 30% ± 14% and 44% ± 19% of that measured in the operation. Conclusions: Considering the shrinkage of the normal esophagus during fixation, a CTV margin of 2.0 cm along the upper long axis and 3.5 cm along the lower long axis should be chosen for radiotherapy for esophageal carcinoma, according to the ratio of shrinkage. Ascending invasion proportion is higher than the descending invasion in that tumor. (authors)

  15. Correlation between measured energy expenditure and clinically obtained variables in trauma and sepsis patients.

    Science.gov (United States)

    Frankenfield, D C; Omert, L A; Badellino, M M; Wiles, C E; Bagley, S M; Goodarzi, S; Siegel, J H

    1994-01-01

    Indirect calorimetry is the preferred method for determining caloric requirements of patients, but availability of the device is limited by high cost. A study was therefore conducted to determine whether clinically obtainable variables could be used to predict metabolic rate. Patients with severe trauma or sepsis who required mechanical ventilation were measured by an open-circuit indirect calorimeter. Several clinical variables were obtained simultaneously. Measurements were repeated every 12 hours for up to 10 days. Twenty-six trauma and 30 sepsis patients were measured 423 times. Mean resting energy expenditure was 36 +/- 7 kcal/kg (trauma) vs 45 +/- 8 kcal/kg (sepsis) (p types.

  16. Applicability of the Modified Ritchie-Knott-Rice Failure Criterion to Examine the Feasibility of Miniaturized Charpy Type SE(B Specimens

    Directory of Open Access Journals (Sweden)

    Toshiyuki Meshii

    2016-01-01

    Full Text Available This paper examined whether the modified Ritchie-Knott-Rice (RKR failure criterion can be applied to examine the feasibility of miniaturized Charpy type SE(B specimens of thickness-to-width ratio B/W=1. The modified RKR failure criterion considered in this paper is the (4δt,σ22c criterion which predicts the onset of cleavage fracture when the midplane crack-opening stress measured at a distance equal to four times the crack-tip opening displacement, denoted as σ22d, exceeds a critical stress σ22c. Specimens with B values of 25, 10, 3, and 2 mm (denoted as 25t, 10t, 3t, and 2t specimens, resp. manufactured with 0.55% carbon steel were tested at 20°C. The results showed that the modified RKR criterion could appropriately predict the occurrence of cleavage fracture accompanied by negligibly small stable crack extension (denoted as KJc fracture naturally for the 25t and 10t specimens. The modified RKR criterion could also predict that KJc fracture does not occur for the 2t specimen. The σ22c obtained from specimens for the 25t and 10t specimens exhibited only a small difference, indicating that the Jc obtained from the 10t specimens can be used to predict the Jc that will be obtained with the 25t specimens.

  17. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    Science.gov (United States)

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    Science.gov (United States)

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  19. Impregnation of soft biological specimens with thermosetting resins and elastomers.

    Science.gov (United States)

    von Hagens, G

    1979-06-01

    A new method for impregnation of biological specimens with thermosetting resins and elastomers is described. The method has the advantage that the original relief of the surface is retained. The impregnation is carried out by utilizing the difference between the high vapor tension of the intermedium (e.g., methylene chloride) and the low vapor tension of the solution to be polymerized. After impregnation, the specimen is subject to polymerization conditions without surrounding embedding material. The optical and mechanical properties can be selected by proper choice from various kinds of resins and different procedures, for example, by complete or incomplete impregnation. Acrylic resins, polyester resins, epoxy resins, polyurethanes and silicone rubber have been found suitable for the method. Excellent results have been obtained using transparent silicone rubber since after treatment the specimens are still flexible and resilient, and have retained their natural appearance.

  20. Influence of thermal conditioning media on Charpy specimen test temperature

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  1. Clinical usefulness of physiological components obtained by factor analysis

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Murata, Hajime; Matsuda, Hirofumi; Yokoyama, Masao; Toyama, Hinako; Satoh, Tomohiko.

    1989-01-01

    The clinical usefulness of physiological components obtained by factor analysis was assessed in 99m Tc-DTPA renography. Using definite physiological components, another dynamic data could be analyzed. In this paper, the dynamic renal function after ESWL (Extracorporeal Shock Wave Lithotripsy) treatment was examined using physiological components in the kidney before ESWL and/or a normal kidney. We could easily evaluate the change of renal functions by this method. The usefulness of a new analysis using physiological components was summarized as follows: 1) The change of a dynamic function could be assessed in quantity as that of the contribution ratio. 2) The change of a sick condition could be morphologically evaluated as that of the functional image. (author)

  2. Bireflectance imaging of coal and carbon specimens

    Energy Technology Data Exchange (ETDEWEB)

    Crelling, J.C. [Department of Geology, 1259 Lincoln Drive, Southern Illinois University, Carbondale, Illinois 62901 (United States); Glasspool, I.J.; Gibbins, J.R.; Seitz, M. [Department of Mechanical Engineering, Imperial College, Exhibition Road, London, SW7 2BX (United Kingdom)

    2005-11-10

    Although bireflectance measurements are routine, to date they have been limited to selected single point measurements. This study uses a 360{sup o} rotating polarizer in the incident light path combined with digital imaging to map the optical bireflectance of a polished specimen over the complete field of view, a system herein referred to as 'Bireflectance Imaging of Coal and Carbon Specimens' (BRICCS). True maximum reflectance maps and maps of polarizer angle for maximum reflectance (to identify co-ordered regions) are obtainable from the same data. A variety of coal, coke, char, graphite, and carbon/carbon specimens have been examined with the BRICCS system and the results demonstrate that the system can produce accurate maximum and apparent minimum reflectance, bireflectance, and extinction angle images. For example, flakes of natural graphite show no bireflectance along their long axis except in areas that have been strained. The images are maps showing the value of every pixel that has been calibrated by mineral reflectance standards. The maps are unique in that they show fields of view that cannot be seen by normal viewing through the microscope. For example, the bireflectance maps show the maximum difference between the maximum and apparent minimum reflectance for each of the million pixels at twenty orientations of the polarizer. (author)

  3. Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

    Science.gov (United States)

    Pothnis, J. R.; Ravikumar, G.; Arya, H.; Yerramalli, Chandra S.; Naik, N. K.

    2018-02-01

    Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x- t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

  4. The incidence and relevance of prostate cancer in radical cystoprostatectomy specimens.

    LENUS (Irish Health Repository)

    Alsinnawi, M

    2012-12-01

    To review the incidence, histopathological features and clinical outcomes of patients with incidental prostate cancer (CaP) found in cystoprostatectomy specimens (CP) excised for bladder cancer and to determine whether these prostate cancers could affect the follow-up strategy.

  5. Utility of pooled urine specimens for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in men attending public sexually transmitted infection clinics in Mumbai, India, by PCR.

    Science.gov (United States)

    Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne

    2005-04-01

    Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.

  6. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  7. [Automated RNA amplification for the rapid identification of Mycobacterium tuberculosis complex in respiratory specimens].

    Science.gov (United States)

    Drouillon, V; Houriez, F; Buze, M; Lagrange, P; Herrmann, J-L

    2006-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis complex (MTB) directly on clinical respiratory specimens is essential for a correct management of patients suspected of tuberculosis. For this purpose PCR-based kits are available to detect MTB in respiratory specimen but most of them need at least 4 hours to be completed. New methods, based on TRC method (TRC: Transcription Reverse transcription Concerted--TRCRapid M. Tuberculosis--Tosoh Bioscience, Tokyo, Japon) and dedicated monitor have been developed. A new kit (TRC Rapid M. tuberculosis and Real-time monitor TRCRapid-160, Tosoh Corporation, Japan) enabling one step amplification and real-time detection of MTB 16S rRNA by a combination of intercalative dye oxazole yellow-linked DNA probe and isothermal RNA amplification directly on respiratory specimens has been tested in our laboratory. 319 respiratory specimens were tested in this preliminary study and results were compared to smear and culture. Fourteen had a positive culture for MTB. Among theses samples, smear was positive in 11 cases (78.6%) and TRC process was positive in 8 cases (57.1%). Overall sensitivity of TRC compared to smear positive samples is 73%. Theses first results demonstrated that a rapid identification of MTB was possible (less than 2 processing hours for 14 specimens and about 1 hour for 1 specimen) in most cases of smear positive samples using ready to use reagents for real time detection of MTB rRNA in clinical samples. New pretreatment and extraction reagents kits to increase the stability of the sputum RNA and the extraction efficiency are now tested in our laboratory.

  8. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    Science.gov (United States)

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  9. Results of the Abbott RealTime HIV-1 Assay for Specimens Yielding “Target Not Detected” Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test▿

    OpenAIRE

    Babady, N. Esther; Germer, Jeffrey J.; Yao, Joseph D. C.

    2009-01-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding “target not detected” results by CTM.

  10. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  11. Experimental Study On Fracture Property Of Double Cantilever Beam Specimen With Aluminum Foam

    Directory of Open Access Journals (Sweden)

    Kim Y.C.

    2015-06-01

    Full Text Available This study aims to investigate double cantilever beam specimen with aluminum foam bonded by spray adhesive to investigate the fracture strength of the adhesive joint experimentally. The fracture energy at opening mode is calculated by the formulae of British Engineering Standard (BS 7991 and International Standard (ISO 11343. For the static experiment, four types of specimens with the heights (h of 25 mm, 30 mm, 35 mm and 40 mm are manufactured and the experimental results are compared with each other. As the height becomes greater, the fracture energy becomes higher. After the length of crack reaches 150 mm, the fracture energy of the specimen (h=35 mm is greater than that of the specimen (h=40 mm. Fatigue test is also performed with DCB test specimen. As the height decreases, the fracture energy becomes higher. By the result obtained from this study, aluminum foam with adhesive joint can be applied to actual composite structure and its fracture property can possibly be anticipated.

  12. 49 CFR 40.105 - What happens if the laboratory reports a result different from that expected for a blind specimen?

    Science.gov (United States)

    2010-10-01

    ... different from that expected for a blind specimen? 40.105 Section 40.105 Transportation Office of the... for a blind specimen? (a) If you are an employer, MRO, or C/TPA who submits a blind specimen, and if... expected results (obtained from the supplier of the blind specimen), and direct the laboratory to determine...

  13. Breast surgical specimen radiographs: How reliable are they?

    International Nuclear Information System (INIS)

    Britton, P.D.; Sonoda, L.I.; Yamamoto, A.K.; Koo, B.; Soh, E.; Goud, A.

    2011-01-01

    Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated 'very reliably' or 'reliably' in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5 mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.

  14. Superconducting glass-ceramics in BiSrCaCu2Al0.5Ox---Comparison between rod and powder compacted specimens

    International Nuclear Information System (INIS)

    Hirata, K.; Abe, Y.

    1991-01-01

    Superconducting properties are studied for glass-ceramics which were prepared by reheating glass rods and the glass powder compacts in the BiSrCaCu 2 Al 0.5 O x system, respectively. The glass-ceramic rod specimens obtained by reheating rod glass at 800--830 degree C for 50 h have a T c (R=0) of 85 K, while the disk specimens obtained by reheating the powered glass compacts in the same way do not exhibit superconductivity above 77 K. This difference in superconductivity between the specimens is discussed in terms of crystallization process and the amount of oxygen absorption of the specimens during heating

  15. The response of pressure vessel steel specimens on drop weight loading

    International Nuclear Information System (INIS)

    Winkler, S.; Kalthoff, J.F.; Gerscha, A.

    1979-01-01

    Load records obtained in instrumented impact tests in general are disturbed by inertia effects. The influence of mechanical damping provisions on these disturbing inertia effects is investigated. Precracked bend specimens are dynamically loaded in a drop weight testing system. The specimens of size 620 mm x 150 mm (25 mm or 50 mm thick) were machined from the pressure vessel steel 22 NiMoCr 37 which was heat treated to achieve a specially hardened condition. The tests were performed at two different low temperatures. The impact velocity was about 4 m/s. As it is usual in instrumented impact testing, the load at the tup of the impining striker is recorded as a function of time during the impact process. In addition the specimen is instrumented by a strain gage close to the crack tip in order to directly measure the stress intensification. Experiments were performed under pure and damped impact conditions. Damping was achieved by utilizing a soft aluminum plate between the striker and the specimen. (orig.)

  16. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Directory of Open Access Journals (Sweden)

    Hongxue Luo

    Full Text Available Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample.Two cervico-vaginal specimens (pseudo self-collected were obtained from 319 women. One was applied to an iFTA Card (FTA then the brush placed in liquid-based medium (LSELF; the other was applied to a new solid media: POI card (POI. The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC.The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC, 81.0% (FTA vs. LDOC, and 82.3% (POI vs. LDOC. LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF, 73.8% (FTA, 95.1% (POI, and 93.4% (LDOC respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both.Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  17. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Science.gov (United States)

    Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang

    2016-01-01

    Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  18. Method for quantifying percentage wood failure in block-shear specimens by a laser scanning profilometer

    Science.gov (United States)

    C. T. Scott; R. Hernandez; C. Frihart; R. Gleisner; T. Tice

    2005-01-01

    A new method for quantifying percentage wood failure of an adhesively bonded block-shear specimen has been developed. This method incorporates a laser displacement gage with an automated two-axis positioning system that functions as a highly sensitive profilometer. The failed specimen is continuously scanned across its width to obtain a surface failure profile. The...

  19. Interpretation of acoustic parameters obtained by EMAR measurement for non-destructive hydrogen concentration measurement in Zr alloy

    International Nuclear Information System (INIS)

    Nakatsuka, Masafumi; Uchida, Katsuya; Miyazaki, Akihiro; Ishii, Yoshiaki

    2007-01-01

    An obvious quantitative relation between hydrogen concentrations in zirconium alloy and acoustic anisotropy parameters obtained by the electromagnetic acoustic resonance (EMAR) method was reported. To elucidate the mechanism, the acoustic parameters were calculated based on the elastic theory and the equation of motion. The acoustic parameters of obtained by the EMAR method were interpreted quantitatively using the anisotropic elastic constants of the specimen, and value calculated from texture data for non-hydrogen charged specimens showed good agreement with those obtained by the EMAR method. Calculated temperature dependence of the acoustic anisotropy for the non-hydrogen charged specimen also agreed well with that by the EMAR method. The consistencies demonstrated that the absolute values of the acoustic parameters for non-hydrogen charged specimen can be calculated from both the texture data of (0002) pole figure and the elastic constants of the specimen. Hydrogen addition up to approximately 650ppm was found not to change the original (0002) pole figure and, correspondingly, no hydrogen concentration dependence of the acoustic parameters was obtained from the calculation. These results implied that the zirconium hydride itself played an important role for the change in the acoustic parameters of the hydrogen charged specimens, and the importance of obtaining the information on the elastic constants of the zirconium hydride was pointed out. (author)

  20. An Inset CT Specimen for Evaluating Fracture in Small Samples of Material

    Science.gov (United States)

    Yahyazadehfar, M.; Nazari, A.; Kruzic, J.J.; Quinn, G.D.; Arola, D.

    2013-01-01

    In evaluations on the fracture behavior of hard tissues and many biomaterials, the volume of material available to study is not always sufficient to apply a standard method of practice. In the present study an inset Compact Tension (inset CT) specimen is described, which uses a small cube of material (approximately 2×2×2 mm3) that is molded within a secondary material to form the compact tension geometry. A generalized equation describing the Mode I stress intensity was developed for the specimen using the solutions from a finite element model that was defined over permissible crack lengths, variations in specimen geometry, and a range in elastic properties of the inset and mold materials. A validation of the generalized equation was performed using estimates for the fracture toughness of a commercial dental composite via the “inset CT” specimen and the standard geometry defined by ASTM E399. Results showed that the average fracture toughness obtained from the new specimen (1.23 ± 0.02 MPa•m0.5) was within 2% of that from the standard. Applications of the inset CT specimen are presented for experimental evaluations on the crack growth resistance of dental enamel and root dentin, including their fracture resistance curves. Potential errors in adopting this specimen are then discussed, including the effects of debonding between the inset and molding material on the estimated stress intensity distribution. Results of the investigation show that the inset CT specimen offers a viable approach for studying the fracture behavior of small volumes of structural materials. PMID:24268892

  1. Transition Fracture Toughness Characterization of Eurofer 97 Steel using Pre-Cracked Miniature Multi-notch Bend Bar Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiang [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sokolov, Mikhail A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linton, Kory D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Clowers, Logan N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Katoh, Yutai [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-11-01

    In this report, we present the feasibility study of using pre-cracked miniature multi-notch bend bar specimens (M4CVN) with a dimension of 45mm (length) x 3.3mm (width) x 1.65mm (thickness) to characterize the transition fracture toughness of Eurofer97 based on the ASTM E1921 Master Curve method. From literature survey results, we did not find any obvious specimen size effects on the measured fracture toughness of unirradiated Eurofer97. Nonetheless, in order to exclude the specimen size effect on the measured fracture toughness of neutron irradiated Eurofer97, comparison of results obtained from larger size specimens with those from smaller size specimens after neutron irradiation is necessary, which is not practical and can be formidably expensive. However, limited literature results indicate that the transition fracture toughness of Eurofer97 obtained from different specimen sizes and geometries followed the similar irradiation embrittlement trend. We then described the newly designed experimental setup to be used for testing neutron irradiated Eurofer97 pre-cracked M4CVN bend bars in the hot cell. We recently used the same setup for testing neutron irradiated F82H pre-cracked miniature multi-notch bend bars with great success. Considering the similarity in materials, specimen types, and the nature of tests between Eurofer97 and F82H, we believe the newly designed experimental setup can be used successfully in fracture toughness testing of Eurofer97 pre-cracked M4CVN specimens.

  2. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  3. Native alunogen: A Raman spectroscopic study of a well-described specimen

    Science.gov (United States)

    Košek, Filip; Culka, Adam; Žáček, Vladimír; Laufek, František; Škoda, Radek; Jehlička, Jan

    2018-04-01

    Alunogen (Al2(SO4)3 · 17H2O) is a common secondary mineral in the terrestrial environment (acid mine drainage, volcanic or coal-fire fumaroles), and is also formed through the acidic weathering of aluminosilicates. Moreover, alunogen has been suggested as a part of the Al-bearing deposits on Mars. The identification of alunogen in secondary sulfate mixtures by Raman spectroscopy strictly depends on good knowledge of alunogen spectral features and band positions. However, comprehensive Raman data of alunogen of natural origin are lacking. This study reports on Raman spectra obtained from two natural specimens originating from a burning coal dump at the Schoeller mine, Kladno, Czech Republic, along with the additional characterizations by infrared spectroscopy, X-ray diffraction, and electron microprobe. For comparison purposes, a Raman spectrum of a synthetic analogue was also obtained. The studied specimens have (Al1.99Fe3+0.01)2 (SO4)3·17H2O as their calculated empirical formula, and the structural parameters correspond to the previously reported data for alunogen. Both natural specimens and the synthetic analogue showed uniform Raman spectra with no extensive band splitting in the sulfate vibrational regions. The most intensive Raman band associated with the symmetric stretching vibration of the SO4 tetrahedra (ν1) is located at 992 cm-1. A multicomponent band was observable in the characteristic region for OH-related vibrations. A small variation in the spectral intensity of the hydroxyl bands suggests that the studied specimens could possibly be slightly dehydrated.

  4. LPTR irradiation of LLL vanadium tensile specimens and LLL Nb--1Zr tensile specimens

    International Nuclear Information System (INIS)

    MacLean, S.C.; Rowe, C.L.

    1977-01-01

    The LPTR irradiation of 14 LLL vanadium tensile specimens and 14 LLL Nb-1Zr tensile specimens is described. Sample packaging, the irradiation schedule and neutron fluences for three energy ranges are given

  5. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  6. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  7. New Procedure for Compacting Prismatic Specimens of Cement-Treated Base Materials

    Directory of Open Access Journals (Sweden)

    Alaitz Linares-Unamunzaga

    2018-06-01

    Full Text Available Understanding the long-term behaviour of cement-treated base materials is a key factor to improve its design and obtain environmentally friendly pavement base materials. Their characterization requires manufacturing prismatic specimens. However, various authors highlight the absence of standardized test methods for fabricating beams in the field and laboratory, which is not an easy task because it depends on the qualification and experience of the testing team. The aim of this paper is to present a new device and procedure for compacting prismatic specimens of cement-treated base materials. In this research, it was used for compacting soil-cement to simulate its performance as a road base material. This device employs elements that are generally available in a concrete laboratory test, such as a vibrating table or prismatic moulds. Once the procedure was established, and in order to verify its suitability, flexural and compressive strength tests were carried out. Results showed that the values obtained were consistent with this material and, despite the heterogeneity of the material, specimens from the same batch provided similar results and, hence, validated the compaction process. This new compacting procedure can improve understanding of the long-term performance of cement-treated materials from flexural and fatigue tests.

  8. Profiling cancer gene mutations in clinical formalin-fixed, paraffin-embedded colorectal tumor specimens using targeted next-generation sequencing.

    Science.gov (United States)

    Zhang, Liangxuan; Chen, Liangjing; Sah, Sachin; Latham, Gary J; Patel, Rajesh; Song, Qinghua; Koeppen, Hartmut; Tam, Rachel; Schleifman, Erica; Mashhedi, Haider; Chalasani, Sreedevi; Fu, Ling; Sumiyoshi, Teiko; Raja, Rajiv; Forrest, William; Hampton, Garret M; Lackner, Mark R; Hegde, Priti; Jia, Shidong

    2014-04-01

    The success of precision oncology relies on accurate and sensitive molecular profiling. The Ion AmpliSeq Cancer Panel, a targeted enrichment method for next-generation sequencing (NGS) using the Ion Torrent platform, provides a fast, easy, and cost-effective sequencing workflow for detecting genomic "hotspot" regions that are frequently mutated in human cancer genes. Most recently, the U.K. has launched the AmpliSeq sequencing test in its National Health Service. This study aimed to evaluate the clinical application of the AmpliSeq methodology. We used 10 ng of genomic DNA from formalin-fixed, paraffin-embedded human colorectal cancer (CRC) tumor specimens to sequence 46 cancer genes using the AmpliSeq platform. In a validation study, we developed an orthogonal NGS-based resequencing approach (SimpliSeq) to assess the AmpliSeq variant calls. Validated mutational analyses revealed that AmpliSeq was effective in profiling gene mutations, and that the method correctly pinpointed "true-positive" gene mutations with variant frequency >5% and demonstrated high-level molecular heterogeneity in CRC. However, AmpliSeq enrichment and NGS also produced several recurrent "false-positive" calls in clinically druggable oncogenes such as PIK3CA. AmpliSeq provided highly sensitive and quantitative mutation detection for most of the genes on its cancer panel using limited DNA quantities from formalin-fixed, paraffin-embedded samples. For those genes with recurrent "false-positive" variant calls, caution should be used in data interpretation, and orthogonal verification of mutations is recommended for clinical decision making.

  9. Georeferencing Animal Specimen Datasets

    NARCIS (Netherlands)

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  10. Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available Concrete cracking strength can be defined as the tensile strength of concrete subjected to pure tension stress. However, as it is difficult to apply direct tension load to concrete specimens, concrete cracking is usually quantified by the modulus of rupture for flexural members. In this study, a new direct tension test setup for cylindrical specimens (101.6 mm in diameter and 203.2 mm in height similar to those used in compression test is developed. Double steel plates are used to obtain uniform stress distributions. Finite element analysis for the proposed test setup is conducted. The uniformity of the stress distribution along the cylindrical specimen is examined and compared with rectangular cross section. Fuzzy image pattern recognition method is used to assess stress uniformity along the specimen. Moreover, the probability of cracking at different locations along the specimen is evaluated using probabilistic finite element analysis. The experimental and numerical results of the cracking location showed that gravity effect on fresh concrete during setting time might affect the distribution of concrete cracking strength along the height of the structural elements.

  11. Improved quality of patient care through routine second review of histopathology specimens prior to multidisciplinary meetings.

    Science.gov (United States)

    Kuijpers, Chantal C H J; Burger, Gerard; Al-Janabi, Shaimaa; Willems, Stefan M; van Diest, Paul J; Jiwa, Mehdi

    2016-10-01

    Double reading may be a valuable tool for improving quality of patient care by identifying diagnostic errors before final sign-out, but standard double reading would significantly increase costs of pathology. We assessed the added value of intradepartmental routine double reading of histopathology specimens prior to multidisciplinary meetings. Diagnoses, treatment plans and prognoses of patients are often discussed at multidisciplinary meetings. As part of the daily routine, all pathology specimens to be discussed at upcoming multidisciplinary meetings undergo prior intradepartmental double reading. We identified all histopathology specimens from 2013 that underwent such double reading and determined major and minor discordance rates based on clinical relevance between the initial and consensus sign-out diagnoses. We included 6796 histopathology specimens that underwent double reading, representing approximately 8% of all histopathology cases at our institution in 2013. Double reading diagnoses were concordant in 6566 specimens (96.6%). Major and minor discordances were observed in 60 (0.9%) and 170 (2.5%) specimens, respectively. Urology specimens had significantly more discordances than other tissues of origin, Gleason grading of prostate cancer biopsies being the most frequent diagnostic problem. Furthermore, premalignant and malignant cases showed significantly higher discordance rates than the rest. The vast majority (90%) of discordances represented changes within the same diagnostic category (eg, malignant to malignant). Routine double reading of histopathology specimens prior to multidisciplinary meetings prevents diagnostic errors. It resulted in about 1% discordant diagnoses of potential clinical significance, indicating that second review is worthwhile in terms of patient safety and quality of patient care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. System for nucleation and propagation of fatigue cracks on SE(B) specimens

    International Nuclear Information System (INIS)

    Rocha, Nirlando Antonio; Gomes Junyor, Jose Onesimo; Reis, Emil; Vilela, Jefferson Jose; Moura, Cassio Melo

    2015-01-01

    The degree of safety that a structural component has against catastrophic fracture in service can be obtained from fracture mechanics parameters. The master curve could be used for integrity evaluation in pressure vessel of nuclear power plant. The pre-crack specimens are used in this evaluation. The tests based on ASTM E 8M and ASTM E 647 standards to determination of material properties related to fracture mechanics, most often performed in a servo-hydraulic drive equipment, are time consuming and costly. This paper presents the development of a system for nucleation and propagation of fatigue cracks on SE(B) specimens. The operating principle consists of a cyclic loading, concentrated in the center of the specimen, transmitted and controlled by an eccentric mechanism. The main contribution of this work is the low-cost technology in the production of fatigue pre-crack, and the possibility of performing the nucleation and propagation of the pre-crack required for obtaining the J IC and CTOD parameters. The experimental results satisfied expectations with respect to the plastic deformation in the crack tip and met the requirements of the standards. (author)

  13. System for nucleation and propagation of fatigue cracks on SE(B) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Nirlando Antonio; Gomes Junyor, Jose Onesimo; Reis, Emil; Vilela, Jefferson Jose, E-mail: nar@cdtn.br, E-mail: ze_onezo@hotmail.com, E-mail: emilr@cdtn.br, E-mail: jjv@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Moura, Cassio Melo, E-mail: cassio.moura@gerdau.com.br [Gerdau S.A., Ouro Branco, MG (Brazil)

    2015-07-01

    The degree of safety that a structural component has against catastrophic fracture in service can be obtained from fracture mechanics parameters. The master curve could be used for integrity evaluation in pressure vessel of nuclear power plant. The pre-crack specimens are used in this evaluation. The tests based on ASTM E 8M and ASTM E 647 standards to determination of material properties related to fracture mechanics, most often performed in a servo-hydraulic drive equipment, are time consuming and costly. This paper presents the development of a system for nucleation and propagation of fatigue cracks on SE(B) specimens. The operating principle consists of a cyclic loading, concentrated in the center of the specimen, transmitted and controlled by an eccentric mechanism. The main contribution of this work is the low-cost technology in the production of fatigue pre-crack, and the possibility of performing the nucleation and propagation of the pre-crack required for obtaining the J{sub IC} and CTOD parameters. The experimental results satisfied expectations with respect to the plastic deformation in the crack tip and met the requirements of the standards. (author)

  14. DNA extraction from herbarium specimens.

    Science.gov (United States)

    Drábková, Lenka Záveská

    2014-01-01

    With the expansion of molecular techniques, the historical collections have become widely used. Studying plant DNA using modern molecular techniques such as DNA sequencing plays an important role in understanding evolutionary relationships, identification through DNA barcoding, conservation status, and many other aspects of plant biology. Enormous herbarium collections are an important source of material especially for specimens from areas difficult to access or from taxa that are now extinct. The ability to utilize these specimens greatly enhances the research. However, the process of extracting DNA from herbarium specimens is often fraught with difficulty related to such variables as plant chemistry, drying method of the specimen, and chemical treatment of the specimen. Although many methods have been developed for extraction of DNA from herbarium specimens, the most frequently used are modified CTAB and DNeasy Plant Mini Kit protocols. Nine selected protocols in this chapter have been successfully used for high-quality DNA extraction from different kinds of plant herbarium tissues. These methods differ primarily with respect to their requirements for input material (from algae to vascular plants), type of the plant tissue (leaves with incrustations, sclerenchyma strands, mucilaginous tissues, needles, seeds), and further possible applications (PCR-based methods or microsatellites, AFLP).

  15. Estimation of Fatigue Crack Growth Behavior of Cracked Specimen Under Mixed-mode Loads

    International Nuclear Information System (INIS)

    Han, Jeong Woo; Woo, Eun Taek; Han, Seung Ho

    2015-01-01

    To estimate the fatigue crack propagation behavior of compact tension shear (CTS) specimen under mixed-mode loads, crack path prediction theories and Tanaka’s equation were applied. The stress intensity factor at a newly created crack tip was calculated using a finite element method via ANSYS, and the crack path and crack increment were then obtained from the crack path prediction theories, Tanaka’s equation, and the Paris’ equation, which were preprogrammed in Microsoft Excel. A new method called the finite element crack tip updating method (FECTUM) was developed. In this method, the finite element method and Microsoft Excel are used to calculate the stress intensity factors and the crack path, respectively, at the crack tip per each crack increment. The developed FECTUM was applied to simulate the fatigue crack propagation of a single-edge notched bending (SENB) specimen under eccentric three-point bending loads. The results showed that the number of cycles to failure of the specimen obtained experimentally and numerically were in good agreement within an error range of less than 3%

  16. Estimation of Fatigue Crack Growth Behavior of Cracked Specimen Under Mixed-mode Loads

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jeong Woo [KIMM, Daejeon (Korea, Republic of); Woo, Eun Taek; Han, Seung Ho [Dong-A University, Busan (Korea, Republic of)

    2015-07-15

    To estimate the fatigue crack propagation behavior of compact tension shear (CTS) specimen under mixed-mode loads, crack path prediction theories and Tanaka’s equation were applied. The stress intensity factor at a newly created crack tip was calculated using a finite element method via ANSYS, and the crack path and crack increment were then obtained from the crack path prediction theories, Tanaka’s equation, and the Paris’ equation, which were preprogrammed in Microsoft Excel. A new method called the finite element crack tip updating method (FECTUM) was developed. In this method, the finite element method and Microsoft Excel are used to calculate the stress intensity factors and the crack path, respectively, at the crack tip per each crack increment. The developed FECTUM was applied to simulate the fatigue crack propagation of a single-edge notched bending (SENB) specimen under eccentric three-point bending loads. The results showed that the number of cycles to failure of the specimen obtained experimentally and numerically were in good agreement within an error range of less than 3%.

  17. 49 CFR 40.71 - How does the collector prepare the specimens?

    Science.gov (United States)

    2010-10-01

    ... this requirement: you may use excess urine to conduct clinical tests (e.g., protein, glucose) if the... 49 Transportation 1 2010-10-01 2010-10-01 false How does the collector prepare the specimens? 40.71 Section 40.71 Transportation Office of the Secretary of Transportation PROCEDURES FOR...

  18. The quantification of specimen size effects in the ductile-brittle transition for C-Mn steel

    International Nuclear Information System (INIS)

    Knee, N.; Worthington, P.J.; Moskovic, R.

    1989-02-01

    It is now generally accepted that the temperature range of the brittle to ductile transition, determined using fracture mechanics specimens, is dependent of the specimen size for ferritic steels. This size effect arises through increasing constraint at the crack tip as the specimen thickness increases together with an increasing volume of material sampled. The size effect can be quantified in terms of a shift in temperature for a given toughness level. This was determined in the present work from fracture toughness/temperature curves obtained by performing fracture toughness tests on eight 100 mm thick compact tension specimens and 40 25 mm thick compact tension specimens over the ductile-brittle transition range of a C-Mn steel. The emphasis is on the development of a practical methodology to quantify the size effect from a limited but still appreciable number of tests. (author)

  19. Specimen-specific modeling of hip fracture pattern and repair.

    Science.gov (United States)

    Ali, Azhar A; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H; Rullkoetter, Paul J; Laz, Peter J

    2014-01-22

    Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. © 2013 Published by Elsevier Ltd.

  20. Validatin of miniaturised tensile testing on DMLS TI6AL4V (ELI specimens

    Directory of Open Access Journals (Sweden)

    Van Zyl, Ian

    2016-11-01

    Full Text Available Direct metal laser sintering (DMLS is a relatively new technology that is developing rapidly. Since DMLS material is created by melting/solidifying tracks and layers from powder, even building geometry can influence the mechanical properties. To certify a material, the testing specimens must be designed and manufactured according to the appropriate standards. Miniaturised tensile DMLS samples could be a good alternative for express quality control, and could reduce the cost of DMLS-specific testing. In this study, as-built and stress-relieved miniaturised tensile DMLS Ti6Al4V (ELI specimens with different surface qualities were investigated. The fracture surfaces and mechanical properties of the mini-tensile specimens were analysed and compared with standard full-sized specimens also manufactured by DMLS. The obtained data showed the applicability of mini-tensile tests for the express analysis of DMLS objects if a correction factor is applied for the calculation of the load-bearing cross-section of the specimen.

  1. MR evaluation of postmenopausal ovarian size. Comparison with surgical specimen

    International Nuclear Information System (INIS)

    Joja, Ikuo; Ishida, Kana; Matsushita, Toshi; Mimura, Seiichi; Yamaguchi, Takuya; Akagi, Noriaki; Miyagi, Yasunari; Hara, Takeshi; Kanazawa, Susumu

    2008-01-01

    We investigated ovarian size after menopause using magnetic resonance (MR) imaging and gross specimens obtained from patients with uterine cancer after menopause in whom normal ovaries were confirmed at the time of surgery. The relationships between size of ovarian long axis and age, the number of years since menopause, and age at menopause were statistically evaluated for 130 ovaries observed in short-axis T 2 -weighted MR images of the uterine corpus and in 147 ovarian gross specimens. No significant relationships were found between size of ovarian long axis and these 3 factors. When the sizes of the ovaries in MR images were compared with those in gross specimens, the latter were larger, with a statistically significant difference. Similarly, when the sizes of the ovaries observed or not observed in MR images were compared in gross specimens, the former were larger, with a statistically significant difference. These results indicate that the size of the ovarian long axis observed in MR images does not accurately reflect the true size of the long axis, but ovarian size strongly affects visualization of the ovaries in MR images after menopause. In addition, these results indicate that there are no significant relationships between ovarian size after menopause and age, the number of years since menopause, or age at menopause. (author)

  2. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  3. Techniques for the recovery and identification of Cryptosporidium oocysts from stool specimens.

    Science.gov (United States)

    Garcia, L S; Bruckner, D A; Brewer, T C; Shimizu, R Y

    1983-07-01

    Due to increasing numbers of patients with documented infections with Cryptosporidium and other coccidia, it is important for the physician and clinical laboratory to be aware of the appropriate diagnostic techniques necessary for organism recovery and identification. Although Cryptosporidium is found in the gastrointestinal tract, tissue biopsies may be insufficient for organism recovery; the examination of stool specimens is a noninvasive procedure and will provide better overall opportunities for organism recovery. Human clinical specimens were examined from 45 patients with confirmed cryptosporidiosis or suspected of having the infection. Tissue biopsy sections, fecal wet preparations, and permanent stained smears were examined. Stool specimens were submitted in 10% Formalin, 2.5% potassium dichromate, and polyvinyl alcohol and were examined for oocysts by using 15 different methods: phase-contrast and light microscopy; Sheather's sugar flotation; Formalin concentration techniques; 10% potassium hydroxide; Giemsa; trichrome; periodic acid-Schiff; modified periodic acid-Schiff; silver methenamine; acridine orange; auramine-rhodamine; Kinyoun acid-fast; Ziehl-Neelsen carbolfuchsin; and a modified acid-fast procedure. Each technique or combination of techniques was assessed by organism quantitation, organism morphology, and ease of visual recognition. Based on these comparative studies, the modified Ziehl-Neelsen carbolfuchsin stain on 10% Formalin-preserved stool is recommended for the recovery and identification of Cryptosporidium.

  4. Chemo-radioresistance of small cell lung cancer cell lines derived from untreated primary tumors obtained by diagnostic bronchofiberscopy

    International Nuclear Information System (INIS)

    Tanio, Yoshiro; Watanabe, Masatoshi; Inoue, Tamotsu

    1990-01-01

    New cell lines of small cell lung cancer (SCLC) were established from specimens of untreated primary tumors biopsied by diagnostic bronchofiberscopy. The advantage of this method was ease of obtaining specimens from lung tumors. Establishment of cell lines was successful with 4 of 13 specimens (30%). Clinical responses of the tumors showed considerable variation, but were well correlated with the in vitro sensitivity of the respective cell lines to chemotherapeutic drugs and irradiation. One of the cell lines was resistant to all drugs tested and irradiation, while another was sensitive to all of them. Although the acquired resistance of SCLC is the biggest problem in treatment, the natural resistance to therapy is another significant problem. Either acquired or natural, resistance mechanisms of SCLC may be elucidated by the use of such cell lines derived from untreated tumors. This method and these SCLC cell lines are expected to be useful for the serial study of biologic and genetic changes of untreated and pre-treated tumors, or primary and secondary tumors. (author)

  5. Yield of two consecutive sputum specimens for the effective diagnosis of pulmonary tuberculosis.

    Directory of Open Access Journals (Sweden)

    Mohammad R Islam

    Full Text Available BACKGROUND: From long instances, it is debatable whether three sputum specimens are required for the diagnosis of pulmonary tuberculosis (TB or TB can be diagnosed effectively using two consecutive sputum specimens. This study was set out to evaluate the significance of examining multiple sputum specimens in diagnosis of TB. METHODS: We retrospectively reviewed the acid-fast bacillus (AFB smear and culture results of three consecutive days' sputum specimens from 413 confirmed TB patients which were detected as part of a larger active case finding study in Dhaka Central Jail, the largest correctional facility in Bangladesh. RESULTS: AFB was detected from 81% (n = 334 patients, of which 89% (n = 297 were diagnosed from the first and additional 9% (n = 30 were from the second sputum specimen. M. tuberculosis growth was observed for 406 patients and 85% (n = 343 were obtained from the first sputum and additional 10% (n = 42 were from the second one. The third specimen didn't show significant additional diagnostic value for the detection of AFB by microscopy or growth of the M. tuberculosis. CONCLUSIONS: We concluded from our study results that examining two consecutive sputum specimens is sufficient enough for the effective diagnosis of TB. It can also decrease the laboratory workload and hence improve the quality of work in settings with high TB burden like Bangladesh.

  6. Yield of two consecutive sputum specimens for the effective diagnosis of pulmonary tuberculosis.

    Science.gov (United States)

    Islam, Mohammad R; Khatun, Razia; Uddin, Mohammad Khaja Mafij; Khan, Md Siddiqur Rahman; Rahman, Md Toufiq; Ahmed, Tahmeed; Banu, Sayera

    2013-01-01

    From long instances, it is debatable whether three sputum specimens are required for the diagnosis of pulmonary tuberculosis (TB) or TB can be diagnosed effectively using two consecutive sputum specimens. This study was set out to evaluate the significance of examining multiple sputum specimens in diagnosis of TB. We retrospectively reviewed the acid-fast bacillus (AFB) smear and culture results of three consecutive days' sputum specimens from 413 confirmed TB patients which were detected as part of a larger active case finding study in Dhaka Central Jail, the largest correctional facility in Bangladesh. AFB was detected from 81% (n = 334) patients, of which 89% (n = 297) were diagnosed from the first and additional 9% (n = 30) were from the second sputum specimen. M. tuberculosis growth was observed for 406 patients and 85% (n = 343) were obtained from the first sputum and additional 10% (n = 42) were from the second one. The third specimen didn't show significant additional diagnostic value for the detection of AFB by microscopy or growth of the M. tuberculosis. We concluded from our study results that examining two consecutive sputum specimens is sufficient enough for the effective diagnosis of TB. It can also decrease the laboratory workload and hence improve the quality of work in settings with high TB burden like Bangladesh.

  7. [Which are the most frequently occurring enteropathogenic bacteria in clinical practice?].

    Science.gov (United States)

    Rohrbach, M; Gualzata, M D; Hollfelder, R; Viollier, A F; Viollier, M; Viollier, E H

    1988-12-10

    Diarrhea is an increasingly frequent clinical finding in Swiss medical practice. One reason is the volume of tourism in countries with different climatic and social circumstances. To obtain an overview of the enteropathogenic bacteria spectrum as a cause of diarrhea, we analyzed 11,163 stool specimens from a representative group of patients throughout Switzerland. Enteropathogenic bacteria were found in 15.2% of all specimens; 50% were Campylobacter jejuni/coli, 35% Salmonella spp., 8% Aeromonas hydrophila group, 4% Shigella spp. and 3% Yersinia enterocolitica. This distribution is taken for all age groups and for both sexes. In the infant age there was a maximum evidence of enteropathogenic bacteria of the female sex. In childhood this maximum concerned to the male sex. Patients older than fifty had no positive stool specimens. As expected the most frequent positive stool specimens were in summer.

  8. Processing of fallopian tube, ovary, and endometrial surgical pathology specimens: A survey of U.S. laboratory practices.

    Science.gov (United States)

    Samimi, Goli; Trabert, Britton; Duggan, Máire A; Robinson, Jennifer L; Coa, Kisha I; Waibel, Elizabeth; Garcia, Edna; Minasian, Lori M; Sherman, Mark E

    2018-03-01

    Many high-grade serous carcinomas initiate in fallopian tubes as serous tubal intraepithelial carcinoma (STIC), a microscopic lesion identified with specimen processing according to the Sectioning and Extensive Examination of the Fimbria protocol (SEE-Fim). Given that the tubal origin of these cancers was recently recognized, we conducted a survey of pathology practices to assess processing protocols that are applied to gynecologic surgical pathology specimens in clinical contexts in which finding STIC might have different implications. We distributed a survey electronically to the American Society for Clinical Pathology list-serve to determine practice patterns and compared results between practice types by chi-square (χ2) tests for categorical variables. Free text comments were qualitatively reviewed. Survey responses were received from 159 laboratories (72 academic, 87 non-academic), which reported diverse specimen volumes and percentage of gynecologic samples. Overall, 74.1% of laboratories reported performing SEE-Fim for risk-reducing surgical specimens (82.5% academic versus 65.7% non-academic, p STIC or early cancer precursors. Published by Elsevier Inc.

  9. Charpy impact test of oxidized and hydrogenated zircaloy using a thin strip specimen

    International Nuclear Information System (INIS)

    Otsuka, Teppei; Hashizume, Kenichi; Sugisaki, Masayasu

    2004-01-01

    The impact properties of an oxidized and a hydrogenated Zircaloy have been studied with an instrumented Charpy machine by using a strip Charpy V-notch specimen (1 mm thick by 4mm wide). Fracture processes such as crack initiation and propagation were examined using load-displacement curves obtained in this study. In the case of the hydrogenated specimen containing preferentially oriented hydrides, an appreciable decrease in the absorbed energy was observed in the crack propagation rather than in the crack initiation. From results of fractographs of the specimen, it was suggested that the reduction of the crack propagation energy of hydrogenated specimen could be attributed to the change of the stress state in the Zircaloy matrix, which was caused by the fracture of hydride in the inner part of specimen. In the case of the specimen oxidized at 973k for 60 min, on which an oxide layer (4 μm in thickness) and oxygen incursion layer (4μm) were formed, the surface layers affected the crack initiation process. The growing oxygen incursion layer, in particular, resulted in the constraint of plastic deformation of the Zircaloy matrix not only in the crack initiation but also in the crack propagation as its thickness increased. (author)

  10. Measurement of temperature fields in specimens of quartz ceramic during surface ablation

    Science.gov (United States)

    Frolov, G. A.; Pasichnyi, V. V.; Suzdal'Tsev, E. I.; Tsyganenko, V. S.

    1989-08-01

    The authors propose a method of mounting thermocouples and have obtained temperature fields within specimens of pure and doped quartz ceramic. The linearity of the dependenceΔ * = fleft( {sqrt tau } right) for deep isotherms has been proved experimentally.

  11. Experimental procedure for the characterization of cyclic behavior from very thin plate specimens

    International Nuclear Information System (INIS)

    Maury, A.; Moulin, D.

    1983-01-01

    Many investigators, including those involved in the INTERNATIONAL BENCHMARK PROJECT ON SIMPLIFIED METHODS FOR ELEVATED TEMPERATURE DESIGN AND ANALYSIS - PROBLEM II, have tried to reproduce experimentally observed behavior by inelastic calculations. Unfortunately, the material characteristics used in the computer code were established from monotonic tensile tests performed with specimens extracted from the plate product itself (1.45 mm thick) employed to construct the ratchetting specimen. It now appears that the cyclic behavior of the material is much more relevant to the phenomenon observed. Hence the need to make this kind of characterization. Nevertheless, the practical problem is to produce cyclic stresses, i.e. tensile and compressive stresses, with very thin specimens. The main difficulty is to prevent the buckling effect. A new special device set up for this particular purpose is described here. The solution adopted was to create uniformly distributed alternative pure bending stresses in the thin plate specimen. Bending moments were produced by two end-grips fixed to the specimen, and these grips were mounted on a conventional test-machine which was displacement-controlled. To reduce tensile and compressive membrane stresses inside the specimen, the grips had two parallel axles of rotation. The forces produced by the machine and the displacements of a number of points of the specimen were continuously recorded during the test, so that cyclically stabilized, bending moments could be evaluated easily for each curvature variation imposed. The very first cyclic experimental data obtained, at room temperature, for the material of the sodium test specimen, a 316 type stainless steel, are presented. It may be noted that the simple specimens were very easy to prepare and hence inexpensive. (orig.)

  12. Effect of laser power and specimen temperature on atom probe analyses of magnesium alloys

    International Nuclear Information System (INIS)

    Oh-ishi, K.; Mendis, C.L.; Ohkubo, T.; Hono, K.

    2011-01-01

    The influence of laser power, wave length, and specimen temperature on laser assisted atom probe analyses for Mg alloys was investigated. Higher laser power and lower specimen temperature led to improved mass and spatial resolutions. Background noise and mass resolutions were degraded with lower laser power and higher specimen temperature. By adjusting the conditions for laser assisted atom probe analyses, atom probe results with atomic layer resolutions were obtained from all the Mg alloys so far investigated. Laser assisted atom probe investigations revealed detailed chemical information on Guinier-Preston zones in Mg alloys. -- Research highlights: → We study performance of UV laser assisted atom probe analysis for Mg alloys. → There is an optimized range of laser power and specimen temperature. → Optimized UV laser enables atom probe data of Mg alloys with high special resolution.

  13. HAADF-STEM atom counting in atom probe tomography specimens: Towards quantitative correlative microscopy.

    Science.gov (United States)

    Lefebvre, W; Hernandez-Maldonado, D; Moyon, F; Cuvilly, F; Vaudolon, C; Shinde, D; Vurpillot, F

    2015-12-01

    The geometry of atom probe tomography tips strongly differs from standard scanning transmission electron microscopy foils. Whereas the later are rather flat and thin (atom probe tomography specimens. Based on simulations (electron probe propagation and image simulations), the possibility to apply quantitative high angle annular dark field scanning transmission electron microscopy to of atom probe tomography specimens has been tested. The influence of electron probe convergence and the benefice of deconvolution of electron probe point spread function electron have been established. Atom counting in atom probe tomography specimens is for the first time reported in this present work. It is demonstrated that, based on single projections of high angle annular dark field imaging, significant quantitative information can be used as additional input for refining the data obtained by correlative analysis of the specimen in APT, therefore opening new perspectives in the field of atomic scale tomography. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Amoxicillin-resistant oral streptococci identified in dental plaque specimens from healthy Japanese adults.

    Science.gov (United States)

    Masuda, Katsuhiko; Nemoto, Hirotoshi; Nakano, Kazuhiko; Naka, Shuhei; Nomura, Ryota; Ooshima, Takashi

    2012-05-01

    Infective endocarditis (IE) is known to be a life-threatening disease and invasive dental procedures are considered to be important factors. Oral amoxicillin (AMPC) is widely used for prophylaxis in patients with heart disorders who are at risk for IE. However, there is only limited information regarding the inhibition of oral bacteria by AMPC. Dental plaque specimens were obtained from 120 healthy Japanese adult subjects, then diluted and streaked onto selective medium for oral streptococci. The minimum inhibitory concentration (MIC) of AMPC was evaluated using a macro-dilution method by Clinical Laboratory Standard Institute (2006). Seven strains with an MIC of AMPC of 16μg/mL or more were isolated from 5 subjects. The bacterial species were confirmed by sequence analysis of 16S rRNA from each strain, which demonstrated that most were Streptococcus sanguinis, followed by Streptococcus oralis. Dental plaque specimens collected from these 5 subjects again after an interval of 2-3 months possessed no strains with an MIC of AMPC of 16μg/mL or more. These findings suggest that strains with a high MIC of AMPC are present in the oral cavities of Japanese adults, though they may be transient rather than inhabitants. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Application Anti Microbial Activity Test and Direct Inoculation of Urinary Specimen Test to Increase the Quality of Results and Decrease the Production Cost in Clinical Microbiology Laboratory, Sanglah General Hospital Hospital, Bali-Indonesia

    Directory of Open Access Journals (Sweden)

    Nyoman Sri-Budayanti

    2012-05-01

    Full Text Available Objective: Urinary tract infection (UTI is the most common bacterial infection in general practice and in hospitals. Fast and accurate urine culture and sensitivity test are needed for adequate therapy. Anti Microbial Activity test (AMA test that is used to detect the presence of antibiotics in urine specimens is not commonly used in clinical microbiology laboratories. Some laboratories are still using indirect inoculation technique using enriched media before inoculating onto the agar media. The aim of this research is to compare results of urinary examination of direct inoculation technique with AMA test with indirect inoculation technique without AMA test.Methods: A number of 210 urine specimens were collected in Clinical Microbiology Laboratory at Sanglah General Hospital within a time period between 16 June until 16 July 2009.Results: Antibiotics were detected in 40% of the urinary specimens; whereas 48.1% showed no evidence of UTI, that is negative AMA test and sterile urinary culture or colony growth < 105 CFU/ml. Only 11.9% of the specimens indicates urinary tract infections. The examination can be completed within 2-3 days which is shorter than indirect inoculation test which require 5-7 days. Direct inoculation technique can reduce the cost of production three-fold the costs require for an indirect inoculation test.Conclusions: Application of AMA test and direct inoculation technique can give results more rapidly, reliable and useful for clinicians. This also decrease the laboratory’s cost of production.

  16. Specimen rejection in laboratory medicine: Necessary for patient safety?

    Science.gov (United States)

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.

  17. Structural strength of cancellous specimens from bovine femur under cyclic compression

    Directory of Open Access Journals (Sweden)

    Kaori Endo

    2016-01-01

    Full Text Available The incidence of osteoporotic fractures was estimated as nine million worldwide in 2000, with particular occurrence at the proximity of joints rich in cancellous bone. Although most of these fractures spontaneously heal, some fractures progressively collapse during the early post-fracture period. Prediction of bone fragility during progressive collapse following initial fracture is clinically important. However, the mechanism of collapse, especially the gradual loss of the height in the cancellous bone region, is not clearly proved. The strength of cancellous bone after yield stress is difficult to predict since structural and mechanical strength cannot be determined a priori. The purpose of this study was to identify whether the baseline structure and volume of cancellous bone contributed to the change in cancellous bone strength under cyclic loading. A total of fifteen cubic cancellous bone specimens were obtained from two 2-year-old bovines and divided into three groups by collection regions: femoral head, neck, and proximal metaphysis. Structural indices of each 5-mm cubic specimen were determined using micro-computed tomography. Specimens were then subjected to five cycles of uniaxial compressive loading at 0.05 mm/min with initial 20 N loading, 0.3 mm displacement, and then unloading to 0.2 mm with 0.1 mm displacement for five successive cycles. Elastic modulus and yield stress of cancellous bone decreased exponentially during five loading cycles. The decrease ratio of yield stress from baseline to fifth cycle was strongly correlated with bone volume fraction (BV/TV, r = 0.96, p < 0.01 and structural model index (SMI, r = − 0.81, p < 0.01. The decrease ratio of elastic modulus from baseline to fifth cycle was also correlated with BV/TV (r = 0.80, p < 0.01 and SMI (r = − 0.78, p < 0.01. These data indicate that structural deterioration of cancellous bone is associated with bone strength after yield stress. This study suggests that

  18. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  19. CT appearances of emphysema and clinical application

    International Nuclear Information System (INIS)

    Wang Xinlian; Ma Daqing; Chen Budong; He Wen; Guan Yansheng; Zhang Yansong; Tang Hongqu; Wang Zhenguang

    2006-01-01

    Objective: To investigate CT appearances of different types of emphysema and to determine the clinic value for differential diagnosis. Methods: Twenty-three specimens with emphysema selected from 33 autopsy specimens were included in this study. All specimens were inflated and fixed by Heitzman's method, then examined by spiral CT scan. The CT appearances of different types of emphysema in every specimen were analyzed. After the specimens were cut into 10 mm thickness slices, the CT- pathologic correlation was done. Fifteen clinical cases confirmed by pathology or clinical process were all performed spiral CT scan and analyzed, including emphysema-accompanying pneumonia 11 cases, emphysema-accompanying nodule 4 cases. Result: Centriacinar emphysema (CAE)can be seen in 21 of 23 specimens, pancinar emphysema(PAE) can be seen in 5 of 23 specimens, all coexisting with CAE. Distal acinar emphysema(DAE) can be seen in 19 of 23 specimens, irregular emphysema can be seen in 3 of 23 specimens. In all specimens, emphysema can be seen in bilateral lung fields, distributing similarly. Seventeen of 23 eases (17/23) showed no less than two types of emphysema. Fourteen cases of emphysema- accompanying pneumonia (clinic: 11 cases, specimen: 3 cases) showed 'pseudocavity' or 'pseudohoneycombing' (emphysema lesion that had not been filled in the consolidation). Four eases of emphysema-accompanying nodule showed 'pseudopleuralhollow' (wall of DAE or bulla connecting with nodule). Conclusion: The CT manifestations of emphysema, the characteristics of distribution and multi- type of emphysema coexisting can help differentiate cystic air space diseases. The characteristics of complications of emphysema, the 'pseudocavity', 'pseudohoneycombing' and 'pseudopleuralhollow', may be help for differential diagnosis. (authors)

  20. Clinical and histologic evaluation of non-surgical periodontal therapy with enamel matrix derivative: a report of four cases.

    Science.gov (United States)

    Mellonig, James T; Valderrama, Pilar; Gregory, Holly J; Cochran, David L

    2009-09-01

    Enamel matrix derivative (EMD) is a composite of proteins that was demonstrated histologically to work as an adjunct to periodontal regenerative surgical therapy. The purpose of this study was to evaluate the clinical and histologic effects of EMD as an adjunct to scaling and root planing. Four patients with severe chronic periodontitis and scheduled to receive complete dentures were accrued. Probing depth and clinical attachment levels were obtained. Unlimited time was allowed for hand and ultrasonic instrumentation. A notch was placed in the root >or=1 to 2 mm from the apical extent of root planing. EMD was inserted into the pocket, and a periodontal dressing was placed. Patients were seen every 2 weeks for plaque control. At 6 months post-treatment, soft tissue measurements were repeated, and the teeth were removed en bloc and prepared for histomorphologic analysis. Probing depth reduction and clinical attachment level gain were obtained in three-fourths of the specimens. Three of the four specimens analyzed histologically demonstrated new cementum, bone, periodontal ligament, and connective tissue attachment coronal to the notch. In one specimen, the gingival margin had receded below the notch. The results were unexpected and may represent an aberration. However, the substantial reduction in deep probing depths and clinical attachment level gain in three of four specimens, in addition to the histologic findings of new cementum, new bone, a new periodontal ligament, and a new connective tissue attachment, suggest that EMD may be useful as an adjunct to scaling and root planing in single-rooted teeth.

  1. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  2. DNA barcode sequencing from old type specimens as a tool in taxonomy: a case study in the diverse genus Eois (Lepidoptera: Geometridae.

    Directory of Open Access Journals (Sweden)

    Patrick Strutzenberger

    Full Text Available In this study we report on the sequencing of the COI barcode region from 96 historical specimens (92 type specimens +4 non-types of Eois. Eois is a diverse clade of tropical geometrid moths and is the target of a number of ongoing studies on life-histories, phylogeny, co-evolution with host plants or parasitoids, and diversity patterns across temporal and spatial dimensions. The unequivocal application of valid names is crucial for all aspects of biodiversity research as well as monitoring and conservation efforts. The availability of barcodes from historical type specimens has the potential to facilitate the much-needed acceleration of species description. We performed non-destructive DNA extraction on the abdomens of Eois specimens between 79 and 157 years of age. We used six primer combinations (recovering between 109 and 130 bp each to target the full-length barcode sequence of each specimen. We were able to obtain sequences for 91 of 96 specimens (success rate 94.8%. Sequence length ranged from 121 bp to full barcode sequences (658 bp, the average sequence length was ~500 bp. We detected a moderately strong and statistically significant negative correlation between specimen age and total sequence length, which is in agreement with expectations. The abdomen proved to be an exceedingly valuable source of DNA in old specimens of Lepidoptera. Barcode sequences obtained in this study are currently being used in an effort towards a step-wise taxonomic revision of Eois. We encourage that DNA barcodes obtained from types specimens should be included in all species descriptions and revisions whenever feasible.

  3. Clinicopathologic features of incidental prostatic adenocarcinoma in radical cystoprostatectomy specimens

    Directory of Open Access Journals (Sweden)

    Vuruskan Hakan

    2011-07-01

    Full Text Available Abstract Background The aim of this study is to review all features of incidentally discovered prostate adenocarcinoma in patients undergoing radical cystoprostatectomy for bladder cancer. Methods The medical charts of 300 male patients who underwent radical cystoprostatectomy for bladder cancer between 1997 and 2005 were retrospectively reviewed. The mean age of the patients was 62 (range 51-75 years. Results Prostate adenocarcinoma was present in 60 (20% of 300 specimens. All were acinar adenocarcinoma. Of these, 40 (66.7% were located in peripheral zone, 20 (33.3% had pT2a tumor, 12 (20% had pT2b tumor, 22(36.7% had pT2c and, 6 (10% had pT3a tumor. Gleason score was 6 or less in 48 (80% patients. Surgical margins were negative in 54 (90% patients, and tumor volume was less than 0.5 cc in 23 (38.3% patients. Of the 60 incidentally detected cases of prostate adenocarcinoma 40 (66.7% were considered clinically significant. Conclusion Incidentally detected prostate adenocarcinoma is frequently observed in radical cystoprostatectomy specimens. The majority are clinically significant.

  4. Fracture toughness evaluation of small notched specimen in consideration of notch effect and loading rate

    International Nuclear Information System (INIS)

    Lee, Baik Woo; Kwon, Dong Il; Jang, Jae Il

    2000-01-01

    Notch effect and loading rate dependency on fracture toughness were considered when evaluating fracture toughness of small notched specimens using the instrumented impact test. Notch effect was analyzed into stress redistribution effect and stress relaxation with a viewpoint of stress triaxiality. Stress redistribution effect was corrected by introducing effective crack length, which was the sum of actual crack length and plastic zone size. Stress relaxation effect was also corrected using elastic stress concentration factor, which would decrease if plastic deformation occurred. As a result, corrected fracture toughness of the notched specimen was very consistent with the reference fracture toughness obtained using precracked specimen. In addition, limiting notch root radius, below which fracture toughness was independent of notch radius, was observed and discussed. Loading rate dependency on fracture toughness, which was obtained from the static three point bending test and the instrumented impact test, was also discussed with stress field in plastic zone ahead of a notch and fracture based on stress control mechanism. (author)

  5. Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants

    International Nuclear Information System (INIS)

    Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail

    2008-01-01

    Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis

  6. Development of sacrificial specimen for fatigue damage prediction of structure (2nd report); Kozobutsu no hiro sonsho yochi no tameno giseishikenhen no kaihatsu ( 2 )

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Y.; Huang, F.; Hada, K.; Sato, A.; Hamada, K.; Iwata, M. [Hiroshima Univ. (Japan)

    1998-12-31

    The study aims at applying the sacrificial specimen developed by the authors of the paper on practical structures, the sacrificial specimens are secured to a smooth specimen and a boxing welded joint, and fatigue tests are performed under varying stress amplitude. The load is cyclic 8 stage block load that has load frequency distribution similar to exponential distribution. Then, a fatigue life prediction of structural element is studied based on monitoring results of the sacrificial specimen. The obtained results are as follows. The sacrificial specimen shows steady fatigue property without occurrence of peeling off or buckling even under varying stress amplitude. A limited accumulated damage value of the sacrificial specimen is obtained under the varying stress amplitude. While arranging the crack growth curve of the varying sacrificial specimen in N/Nf, they show almost the same shape not depending on the life. The prediction method of fatigue life of a structure is described based on monitoring results of the sacrificial specimen. 9 refs., 16 figs., 2 tabs.

  7. The AIDS and Cancer Specimen Resource: Role in HIV/AIDS scientific discovery

    Directory of Open Access Journals (Sweden)

    McGrath Michael S

    2007-03-01

    Full Text Available Abstract The AIDS Cancer and Specimen Resource (ACSR supports scientific discovery in the area of HIV/AIDS-associated malignancies. The ACSR was established as a cooperative agreement between the NCI (Office of the Director, Division of Cancer Treatment and Diagnosis and regional consortia, University of California, San Francisco (West Coast, George Washington University (East Coast and Ohio State University (Mid-Region to collect, preserve and disperse HIV-related tissues and biologic fluids and controls along with clinical data to qualified investigators. The available biological samples with clinical data and the application process are described on the ACSR web site. The ACSR tissue bank has more than 100,000 human HIV positive specimens that represent different processing (43, specimen (15, and anatomical site (50 types. The ACSR provides special biospecimen collections and prepares speciality items, e.g., tissue microarrays (TMA, DNA libraries. Requests have been greatest for Kaposi's sarcoma (32% and non-Hodgkin's lymphoma (26%. Dispersed requests include 83% tissue (frozen and paraffin embedded, 18% plasma/serum and 9% other. ACSR also provides tissue microarrays of, e.g., Kaposi's sarcoma and non-Hodgkin's lymphoma, for biomarker assays and has developed collaborations with other groups that provide access to additional AIDS-related malignancy specimens. ACSR members and associates have completed 63 podium and poster presentations. Investigators have submitted 125 letters of intent requests. Discoveries using ACSR have been reported in 61 scientific publications in notable journals with an average impact factor of 7. The ACSR promotes the scientific exploration of the relationship between HIV/AIDS and malignancy by participation at national and international scientific meetings, contact with investigators who have productive research in this area and identifying, collecting, preserving, enhancing, and dispersing HIV

  8. Prevalence of mabDAS-1 positivity in biopsy specimens from the esophagogastric junction.

    Science.gov (United States)

    Rogge-Wolf, Claudia; Seldenrijk, Cornelis A; Das, Kiron M; Timmer, Robin; Breumelhof, Ronald; Smout, André J P M; Amenta, Peter S; Griffel, Louis H

    2002-12-01

    Intestinal metaplasia (IM) is a precursor for malignancies at the esophagogastric junction. A monoclonal antibody, mAbDAS-1, can probably identify cellular characteristics of IM before the appearance of goblet cells. The aim of this study was to examine the prevalence of mAbDAS-1 positivity in biopsies from the squamocolumnar junction (SCJ) and to correlate this positivity with the presence of IM and clinical findings. In 559 patients, reflux symptoms were scored, and the presence of reflux esophagitis and hiatus hernia was evaluated during endoscopy. Two biopsy specimens were obtained from the SCJ. In a subset of patients (n = 99), biopsies from the endoscopically defined cardiac region (2 cm distal to proximal margin of gastric folds) were available. Biopsy specimens were stained with hematoxylin and eosin, Alcian Blue, modified Giemsa, and mAbDAS-1. mAbDAS-1 positivity was observed in the SCJ biopsies of 201 of 486 (41.4%) patients without IM and in 64 of 73 (87.7%) patients with IM. Patients without IM but with antibody positivity showed similar histological characteristics as patients with IM at the SCJ. Biopsies of 123 of 559 patients (22%) revealed a columnar-cuboidal epithelium, which was found to be mAbDAS-1 positive in 64.2% (77 of 123). Tissue specimens from the cardiac region without IM stained positive in 14.2% (13 of 91), 12 of those also stained at the SCJ. In patients without IM, a high prevalence of mAbDAS-1 positivity was observed. Biopsies of these patients showed similar histological characteristics as patients with IM. Although not all patients exhibiting this reactivity may develop IM, mAbDAS-1 reactivity may help in the understanding of the histogenesis of IM at the SCJ.

  9. Fatal Pasteurella haemolytica pneumonia in bighorn sheep after direct contact with clinically normal domestic sheep.

    Science.gov (United States)

    Foreyt, W J

    1989-03-01

    Six Rocky Mountain bighorn sheep were raised in captivity from birth (n = 5) or taken from the wild as a lamb (n = 1). After the bighorn sheep were in captivity for over a year, 6 clinically normal domestic sheep were placed on the 2 ha of pasture on which the bighorn sheep were kept. Nasal swab specimens were obtained from all sheep at the time the domestic sheep were introduced. Pasteurella haemolytica was isolated from swab specimens obtained from 4 of 6 domestic sheep, but not from specimens obtained from the bighorn sheep. All 6 bighorn sheep died of acute hemorrhagic pneumonia after exposure to domestic sheep. Death in the bighorn sheep occurred on days 4, 27, 27, 29, 36, or 71 after initial exposure to domestic sheep. Pasteurella haemolytica was isolated from respiratory tract tissue specimens of all bighorn sheep at the time of death. None of the domestic sheep were clinically ill during the study. At the end of the study, 3 of 6 domestic sheep were euthanatized, and at necropsy, P haemolytica was isolated from 2 of them. The most common serotypes in bighorn and domestic sheep were P haemolytica T-3 and A-2. Other serotypes isolated included P haemolytica A-1, A-9, and A-11 in bighorn sheep and A-1 in domestic sheep. On the basis of results of this study and of other reports, domestic sheep and bighorn sheep should not be managed in proximity to each other because of the potential fatal consequences in bighorn sheep.

  10. Miniature Precracked Charpy Specimens for Measuring the Master Curve Reference Temperature of RPV Steels at Impact Loading Rates

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.; Puzzolante, L.

    2008-10-15

    In the framework of the 2006 Convention, we investigated the applicability of fatigue precracked miniature Charpy specimens of KLST type (MPCC - B = 3 mm, W = 4 mm and L = 27 mm) for impact toughness measurements, using the well-characterized JRQ RPV steel. In the ductile to-brittle transition region, MPCC tests analyzed using the Master Curve approach and compared to data previously obtained from PCC specimens had shown a more ductile behavior and therefore un conservative results. In the investigation presented in this report, two additional RPV steels have been used to compare the performance of impact-tested MPCC and PCC specimens in the transition regime: the low-toughness JSPS steel and the high-toughness 20MnMoNi55 steel. The results obtained (excellent agreement for 20MnMoNi55 and considerable differences between T0 values for JSPS) are contradictory and do not presently allow qualifying the MPCC specimens as a reliable alternative to PCC samples for impact toughness measurements.

  11. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    Science.gov (United States)

    Beltrán-Fernández, J. A.; Hernández-Gómez, L. H.; Ruiz-Muñoz, E.; González-Rebattú, A.; Rodríguez-Cañizo, R. G.; Urriolagoitia-Calderón, G.; Urriolagoitia-Sosa, G.; Hernández-Moreno, H.

    2009-08-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  12. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    International Nuclear Information System (INIS)

    Beltran-Fernandez, J A; Hernandez-Gomez, L H; Ruiz-Munoz, E; Urriolagoitia-Calderon, G; Urriolagoitia-Sosa, G; Gonzalez-Rebattu, A; RodrIguez-Canizo, R G; Hernandez-Moreno, H

    2009-01-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  13. Introducing 3-Dimensional Printing of a Human Anatomic Pathology Specimen: Potential Benefits for Undergraduate and Postgraduate Education and Anatomic Pathology Practice.

    Science.gov (United States)

    Mahmoud, Amr; Bennett, Michael

    2015-08-01

    Three-dimensional (3D) printing, a rapidly advancing technology, is widely applied in fields such as mechanical engineering and architecture. Three-dimensional printing has been introduced recently into medical practice in areas such as reconstructive surgery, as well as in clinical research. Three-dimensionally printed models of anatomic and autopsy pathology specimens can be used for demonstrating pathology entities to undergraduate medical, dental, and biomedical students, as well as for postgraduate training in examination of gross specimens for anatomic pathology residents and pathology assistants, aiding clinicopathological correlation at multidisciplinary team meetings, and guiding reconstructive surgical procedures. To apply 3D printing in anatomic pathology for teaching, training, and clinical correlation purposes. Multicolored 3D printing of human anatomic pathology specimens was achieved using a ZCorp 510 3D printer (3D Systems, Rock Hill, South Carolina) following creation of a 3D model using Autodesk 123D Catch software (Autodesk, Inc, San Francisco, California). Three-dimensionally printed models of anatomic pathology specimens created included pancreatoduodenectomy (Whipple operation) and radical nephrectomy specimens. The models accurately depicted the topographic anatomy of selected specimens and illustrated the anatomic relation of excised lesions to adjacent normal tissues. Three-dimensional printing of human anatomic pathology specimens is achievable. Advances in 3D printing technology may further improve the quality of 3D printable anatomic pathology specimens.

  14. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  15. Histology of periapical lesions obtained during apical surgery.

    Science.gov (United States)

    Schulz, Malte; von Arx, Thomas; Altermatt, Hans Jörg; Bosshardt, Dieter

    2009-05-01

    The aim of this was to evaluate the histology of periapical lesions in teeth treated with periapical surgery. After root-end resection, the root tip was removed together with the periapical pathological tissue. Histologic sectioning was performed on calcified specimens embedded in methylmethacrylate (MMA) and on demineralized specimens embedded in LR White (Fluka, Buchs, Switzerland). The samples were evaluated with light and transmission electron microscopy (TEM). The histologic findings were classified into periapical abscesses, granulomas, or cystic lesions (true or pocket cysts). The final material comprised 70% granulomas, 23% cysts and 5% abscesses, 1% scar tissues, and 1% keratocysts. Six of 125 samples could not be used. The cystic lesions could not be subdivided into pocket or true cysts. All cysts had an epithelium-lined cavity, two of them with cilia-lined epithelium. These results show the high incidence of periapical granulomas among periapical lesions obtained during apical surgery. Periapical abscesses were a rare occasion. The histologic findings from samples obtained during apical surgery may differ from findings obtained by teeth extractions. A determination between pocket and true apical cysts is hardly possible when collecting samples by apical surgery.

  16. Production of iodine-123 radiobiological specimen on 25 MeV electron beam

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Starodub, G.Ya.; Buklanov, G.V.; Korotkin, Yu.S.; Belov, A.G.

    1988-01-01

    The technique is described and experimental results are presented for production of radioactive specimen-iodine-123 for medical biological investigations. It is shown that in ten hour irradiation of 124 Xe enriched target of 10 g weight by the 25 MeV electron beam at MT-25 microtron short lived 123 I with activity of about 200 mCl can be accumulated. The procedure was developed for extraction of radioactive atoms and preparing the solution that permits to obtain during 1-1.5 h after the end of irradiation the specimen which satisfies all pharmacopeia requirements. It follows from the results that using small-size electron accelerators with the beam energy up to 25 MeV permits to organize economical and large-scale production of high quality radioactive specimen of 123 I for servicing a large region of this country. 14 refs.; 4 figs.; 1 tab

  17. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  18. Recalibrating the Ginkgo Stomatal Index Proxy for Past CO2 with Herbarium Specimens

    Science.gov (United States)

    Conde, G. D.; Retallack, G.

    2015-12-01

    The stomatal index of plant cuticles is inversely related to atmospheric CO2 concentrations, as calibrated from greenhouse experiments and herbarium specimens. Such calibration data for Ginkgo biloba are available for the ongoing rise in atmospheric CO2 and for high levels of CO2 anticipated in the future, but lacking for low CO2 levels of preindustrial and glacial ages. The oldest modern specimen that we have been able to obtain consists of leaf fragments collected in 1829 and provided by Arne Anderberg from the Swedish Natural History Museum. The specimen was labeled "Argentina", but also "Hortus Botanicus Augustinus", a garden founded in 1638 in Amsterdam, Netherlands. Ginkgo has a very thin cuticle that is difficult to prepare, but images very similar to cuticular preparation can be obtained by backscatter SEM imagery. We also obtained secondary SEM images of the same areas and counted 13 images with 6,184 cells from five leaf fragments. Our analyses yield a stomatal index of 10.9 ± 0.9 % for an atmospheric CO2 of 286 ppm, as determined by ice core data from Ciais and Sabine for IPCC-2013. This value is lower than from previous calibration curves for this level of CO2 and changes their curvature. With additional late nineteenth, twentieth and twenty-first century leaves, we can improve both the precision and lower limits of the transfer function for atmospheric CO2 from Ginkgo stomatal index last revised in 2009.

  19. Progress in Tissue Specimens Alternative for the Driver Genes Testing of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yan SUN

    2015-06-01

    Full Text Available Target treatment based on driver genes in advanced non-small cell lung cancer is very important currently. Tumor tissues is the gold standard for driver genes testing. However, most of patients could not get the gene information for lack of enough tissues. To explore the tissue specimens alternatives is a hot spot in clinical work. This report reviews the tissue specimen alternatives of driver gene testing in non-small cell lung cancer.

  20. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  1. Bulk specimen X-ray microanalysis of freeze-fractured, freeze-dried tissues in gerontological research

    International Nuclear Information System (INIS)

    Nagy, I.

    1988-01-01

    The rationale for choosing the freeze-fracture freeze-drying (FFFD) method of biological bulk specimen preparation as well as the theoretical and practical problems of this method are treated. FFFD specimens are suitable for quantitative X-ray microanalysis of biologically relevant elements. Although the spatial resolution of this analytical technique is low, the application of properly selected bulk standard crystals as well as the measurement of the intracellular water and dry mass content by means of another method developed in the same laboratory, allow us to obtain useful information about the age-dependent changes of ionic composition in the main intracellular compartments. The paper summarizes the problems with regard to specimen preparation, beam penetration and the quantitative analysis of FFFD specimens. The method has been applied so far mainly for the analysis of intranuclear and intracytoplasmic concentrations of Na, C1 and K in various types of cells and has resulted in a significant contribution to our understanding of the cellular mechanisms of aging. 84 references

  2. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  3. Utility of bronchial lavage fluids for epithelial growth factor receptor mutation assay in lung cancer patients: Comparison between cell pellets, cell blocks and matching tissue specimens

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Nakata, Rie; Negishi, Tatsuya; Yamamoto, Hiroshi; Shiina, Takayuki; Shigeto, Shohei; Matsuda, Kazuyuki; Kobayashi, Yukihiro; Honda, Takayuki

    2018-01-01

    The detection of epidermal growth factor receptor (EGFR) mutations is necessary for the selection of suitable patients with non-small cell lung cancer (NSCLC) for treatment with EGFR tyrosine kinase inhibitors. Cytology specimens are known to be suitable for EGFR mutation detection, although tissue specimens should be prioritized; however, there are limited studies that examine the utility of bronchial lavage fluid (BLF) in mutation detection. The purpose of the present study was to investigate the utility of BLF specimens for the detection of EGFR mutations using a conventional quantitative EGFR polymerase chain reaction (PCR) assay. Initially, quantification cycle (Cq) values of cell pellets, cell-free supernatants and cell blocks obtained from three series of 1% EGFR mutation-positive lung cancer cell line samples were compared for mutation detection. In addition, PCR analysis of BLF specimens obtained from 77 consecutive NSCLC patients, detecting EGFR mutations was validated, and these results were compared with those for the corresponding formalin-fixed paraffin-embedded (FFPE) tissue specimens obtained by surgical resection or biopsy of 49 of these patients. The Cq values for mutation detection were significantly lower in the cell pellet group (average, 29.58) compared with the other groups, followed by those in cell-free supernatants (average, 34.15) and in cell blocks (average, 37.12) for all three series (P<0.05). Mutational status was successfully analyzed in 77 BLF specimens, and the results obtained were concordant with those of the 49 matching FFPE tissue specimens. Notably, EGFR mutations were even detected in 10 cytological specimens that contained insufficient tumor cells. EGFR mutation testing with BLF specimens is therefore a useful and reliable method, particularly when sufficient cancer cells are not obtained. PMID:29399190

  4. The Alaska Area Specimen Bank: a tribal-federal partnership to maintain and manage a resource for health research.

    Science.gov (United States)

    Parkinson, Alan J; Hennessy, Thomas; Bulkow, Lisa; Smith, H Sally

    2013-01-01

    Banked biospecimens from a defined population are a valuable resource that can be used to assess early markers for illness or to determine the prevalence of a disease to aid the development of intervention strategies to reduce morbidity and mortality. The Alaska Area Specimen Bank (AASB) currently contains 266,353 residual biologic specimens (serum, plasma, whole blood, tissue, bacterial cultures) from 83,841 persons who participated in research studies, public health investigations and clinical testing conducted by the U.S. Public Health Service and Alaska Native tribal health organisations dating back to 1961. The majority (95.7%) are serum specimens, 77% were collected between 1981 and 1994 and 85% were collected from Alaska Native people. Oversight of the specimen bank is provided by a working group with representation from tribal, state and federal health organisations, the Alaska Area IRB and a specimen bank committee which ensures the specimens are used in accordance with policies and procedures developed by the working group.

  5. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    Science.gov (United States)

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  6. Recent advances in FIB-TEM specimen preparation techniques

    International Nuclear Information System (INIS)

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  7. Analysis of the truth loading conditions of a austenitic CT specimen during a SCC experiment

    International Nuclear Information System (INIS)

    Marie, S.; Guerre, C.; Herms, E.

    2012-01-01

    With the aim to investigate the influence of strain hardening on the stainless steels susceptibility to stress corrosion cracking, tests were conducted in PWR environment on CT specimens, taken from a 316L stainless steel sheet cold rolled to 40% in thickness reduction. The initial cracks obtained by the fatigue pre-cracking have an atypical 'V' shape with smaller propagation in the center of the CT thickness compared to nominal propagation observed at both sides. The initial explanation was to consider a stress intensity factor derived from classical reference solution on the basis of a straight crack front, and considering the local value of the crack depth in the equation. This assumption raised several problems analyses in this paper. This particular shape of the initial defect may be related to several factors, and partly to the 40% cold rolling. It is likely that the hardening is not uniform, with a higher rate at the specimen sides than in the central area. In addition, significant residual stresses due to the gradient of mechanical properties are observed. Due to the high rate of work hardening by rolling of the sheet metal, a gradient of the mechanical properties through the thickness was determined, and the residual stresses profile induced by this process was measured. The variations obtained are consistent with each other: the material is more hardened in the vicinity of specimen surface and residual stresses are compressive in nature in the central part of the specimen and of tensile type on the flanks. All these data were firstly considered in order to assess their role regarding the particular form of the initial crack front obtained after fatigue: the 3D finite element calculations taking into account the true shape of the crack front demonstrate the relationship between the characteristics of the experimental crack front obtained after fatigue pre-cracking and the residual stresses. Moreover, from the residual stresses measured on the plate where

  8. Reliability of 46,XX results on miscarriage specimens: a review of 1,222 first-trimester miscarriage specimens.

    Science.gov (United States)

    Lathi, Ruth B; Gustin, Stephanie L F; Keller, Jennifer; Maisenbacher, Melissa K; Sigurjonsson, Styrmir; Tao, Rosina; Demko, Zach

    2014-01-01

    To examine the rate of maternal contamination in miscarriage specimens. Retrospective review of 1,222 miscarriage specimens submitted for chromosome testing with detection of maternal cell contamination (MCC). Referral centers requesting genetic testing of miscarriage specimens at a single reference laboratory. Women with pregnancy loss who desire complete chromosome analysis of the pregnancy tissue. Analysis of miscarriage specimens using single-nucleotide polymorphism (SNP) microarray technology with bioinformatics program to detect maternal cell contamination. Chromosome content of miscarriages and incidence of 46,XX results due to MCC. Of the 1,222 samples analyzed, 592 had numeric chromosomal abnormalities, and 630 were normal 46,XX or 46,XY (456 and 187, respectively). In 269 of the 46,XX specimens, MCC with no embryonic component was found. With the exclusion of maternal 46,XX results, the chromosomal abnormality rate increased from 48% to 62%, and the ratio for XX to XY results dropped from 2.6 to 1.0. Over half of the normal 46,XX results in miscarriage specimens were due to MCC. The use of SNPs in MCC testing allows for precise identification of chromosomal abnormalities in miscarriage as well as MCC, improving the accuracy of products of conception testing. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  9. A computational approach to distinguish somatic vs. germline origin of genomic alterations from deep sequencing of cancer specimens without a matched normal.

    Directory of Open Access Journals (Sweden)

    James X Sun

    2018-02-01

    Full Text Available A key constraint in genomic testing in oncology is that matched normal specimens are not commonly obtained in clinical practice. Thus, while well-characterized genomic alterations do not require normal tissue for interpretation, a significant number of alterations will be unknown in whether they are germline or somatic, in the absence of a matched normal control. We introduce SGZ (somatic-germline-zygosity, a computational method for predicting somatic vs. germline origin and homozygous vs. heterozygous or sub-clonal state of variants identified from deep massively parallel sequencing (MPS of cancer specimens. The method does not require a patient matched normal control, enabling broad application in clinical research. SGZ predicts the somatic vs. germline status of each alteration identified by modeling the alteration's allele frequency (AF, taking into account the tumor content, tumor ploidy, and the local copy number. Accuracy of the prediction depends on the depth of sequencing and copy number model fit, which are achieved in our clinical assay by sequencing to high depth (>500x using MPS, covering 394 cancer-related genes and over 3,500 genome-wide single nucleotide polymorphisms (SNPs. Calls are made using a statistic based on read depth and local variability of SNP AF. To validate the method, we first evaluated performance on samples from 30 lung and colon cancer patients, where we sequenced tumors and matched normal tissue. We examined predictions for 17 somatic hotspot mutations and 20 common germline SNPs in 20,182 clinical cancer specimens. To assess the impact of stromal admixture, we examined three cell lines, which were titrated with their matched normal to six levels (10-75%. Overall, predictions were made in 85% of cases, with 95-99% of variants predicted correctly, a significantly superior performance compared to a basic approach based on AF alone. We then applied the SGZ method to the COSMIC database of known somatic variants

  10. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  11. Crashworthiness Analysis and Evaluation of Fuselage Section with Sub-floor Composite Sinusoidal Specimens

    Directory of Open Access Journals (Sweden)

    H.L. Mou

    Full Text Available Abstract Crashworthiness is one of the main concerns in civil aviation safety particularly with regard to the increasing ratio of carbon fiber reinforced plastic (CFRP in aircraft primary structures. In order to generate dates for model validations, the mechanical properties of T700/3234 were obtained by material performance tests, and energy-absorbing results were gained by quasi-static crushing tests of composite sinusoidal specimens. The correctness of composite material model and single-layer finite element model of composite sinusoidal specimens were verified based on the simulation results and test results that were in good agreement. A typical civil aircraft fuselage section with composite sinusoidal specimens under cargo floor was suggested. The crashworthiness of finite element model of fuselage section was assessed by simulating the vertical drop test subjected to 7 m/s impact velocity, and the influences of different thickness of sub-floor composite sinusoidal specimens on crashworthiness of fuselage section were also analyzed. The simulation results show that the established finite element model can accurately simulate the crushing process of composite sinusoidal specimens; the failure process of fuselage section is more stable, and the safety of occupants can be effectively improved because of the smaller peak accelerations that was limited to human tolerance, a critical thickness of sub-floor composite sinusoidal specimens can restrict the magnitude of acceleration peaks, which has certain reference values for enhancing crashworthiness capabilities of fuselage section and improving the survivability of passengers.

  12. Correlations between Standard and Miniaturised Charpy-V Specimens

    International Nuclear Information System (INIS)

    Lucon, E.; Van Walle, E.; Fabry, A.; Puzzolante, J.-L.; Verstrepen, A.; Vosch, R.; Van de Velde, L.

    1998-12-01

    A total of 565 instrumented impact tests (232 performed on full-size and 333 on sub-size Charpy-V specimens) have been analysed in order to derive meaningful assumptions on the correlations existing between test results obtained on specimens of different size. Nine materials (pressure vessel steels) have been considered, in both as-received and irradiated state, for a total of 19 conditions examined. For the analysis of data, conventional as well novel approaches have been investigated; former ones, based on a review of the existing literature, include predictions of USE values by the use of normalization factors (NF), shifts of index temperatures related to energy/lateral expansion/shear fracture levels, and a combination of both approaches (scaling and shifting of energy curves). More original and recent proposals have also been verified, available in the literature but also proposed by SCK-CEN in the frame of enhanced surveillance of nuclear reactor pressure vessels. Conclusions have been drawn regarding the applicability and reliability of these methodologies, and recommendations have been given for future developments of the activities on this topic

  13. Design of specimen for weld residual stress simulation

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Park, Jong Sun; Lee, Kyung Soo

    2008-01-01

    The objective of this study is to design a laboratory specimen for simulating residual stress of circumferential butt welding of pipe. Specimen type and method for residual stress generation were proposed based on the review of prior studies and parametric finite element simulation. To prove the proposed specimen type and loading method, the residual stress was generated using the designed specimen by applying proposed method and was measured. The measured residual stress using X-ray diffraction reasonably agreed with the results of finite element simulation considered in the specimen design. Comparison of residual strains measured at several locations of specimen and given by finite element simulation also showed good agreement. Therefore, it is indicated that the designed specimen can reasonably simulate the residual stress of circumferential butt welding of pipe

  14. Enterovirus D68 detection in respiratory specimens: Association with severe disease.

    Science.gov (United States)

    Engelmann, Ilka; Fatoux, Marie; Lazrek, Mouna; Alidjinou, Enagnon K; Mirand, Audrey; Henquell, Cécile; Dewilde, Anny; Hober, Didier

    2017-07-01

    Molecular techniques increased the number of documented respiratory infections. In a substantial number of cases the causative agent remains undetected. Since August 2014, an increase in Enterovirus(EV)-D68 infections was reported. We aimed to investigate epidemiology and clinical relevance of EV-D68. From June to December 2014 and from September to December 2015, 803 and 847 respiratory specimens, respectively, were tested for respiratory viruses with a multiplex RT-PCR. This multiplex RT-PCR does not detect EV-D68. Therefore, 457 (2014) and 343 (2015) specimens with negative results were submitted to an EV-specific-RT-PCR. EV-positive specimens were tested with an EV-D68-specific-RT-PCR and genotyped. Eleven specimens of 2014 tested positive in the EV-specific-RT-PCR and of these seven were positive in the EV-D68-specific-RT-PCR. Typing confirmed these as EV-D68. Median age of EV-D68-positive patients was 3 years (1 month-91 years). Common symptoms included fever (n = 6, 86%), respiratory distress (n = 5, 71%), and cough (n = 4, 57%). All EV-D68-positive patients were admitted to hospital, 4 (57%) were admitted to intensive care units and 6 (86%) received oxygen. One patient suffered from acute flaccid paralysis. Seven specimens of 2015 were positive in the EV-specific-RT-PCR but negative in the EV-D68-specific-RT-PCR. In conclusion, use of an EV-specific-RT-PCR allowed us to detect EV-D68 circulation in autumn 2014 that was not detected by the multiplex RT-PCR and was associated with severe disease. © 2017 Wiley Periodicals, Inc.

  15. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    International Nuclear Information System (INIS)

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  16. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    In recent years, technological advances such as computers have been employed in teaching gross anatomy at all levels of education, even in professional schools such as medical and veterinary medical colleges. Benefits of computer based instructional tools for gross anatomy include the convenience of not having to physically view or dissect a cadaver. Anatomy educators debate over the advantages versus the disadvantages of computer based resources for gross anatomy instruction. Many studies, case reports, and editorials argue for the increased use of computer based anatomy educational tools, while others discuss the necessity of dissection for various reasons important in learning anatomy, such as a three-dimensional physical view of the specimen, physical handling of tissues, interactions with fellow students during dissection, and differences between specific specimens. While many articles deal with gross anatomy education using computers, there seems to be a lack of studies investigating the use of computer based resources as an assessment tool for gross anatomy, specifically using the Apple application QuickTime Virtual Reality (QTVR). This study investigated the use of QTVR movie modules to assess if using computer based QTVR movie module assessments were equal in quality to actual physical specimen examinations. A gross anatomy course in the College of Veterinary Medicine at Cornell University was used as a source of anatomy students and gross anatomy examinations. Two groups were compared, one group taking gross anatomy examinations in a traditional manner, by viewing actual physical specimens and answering questions based on those specimens. The other group took the same examinations using the same specimens, but the specimens were viewed as simulated three-dimensional objects in a QTVR movie module. Sample group means for the assessments were compared. A survey was also administered asking students' perceptions of quality and user-friendliness of the QTVR

  17. Evaluation of irradiated coating material specimens

    International Nuclear Information System (INIS)

    Lee, Yong Jin; Nam, Seok Woo; Cho, Lee Moon

    2007-12-01

    Evaluation result of irradiated coating material specimens - Coating material specimens radiated Gamma Energy(Co 60) in air condition. - Evaluation conditions was above 1 X 10 4 Gy/hr, and radiated TID 2.0 X 10 6 Gy. - The radiated coating material specimens, No Checking, Cracking, Flaking, Delamination, Peeling and Blistering. - Coating system at the Kori no. 1 and APR 1400 Nuclear power plant, evaluation of irradiated coating materials is in accordance with owner's requirement(2.0 X 10 6 Gy)

  18. Histopathological Study of Splenectomy Specimens with Correlation with Age, Sex, and Cause of Splenectomy.

    Directory of Open Access Journals (Sweden)

    Dr Hiral Patel

    2016-12-01

    Full Text Available Spleen is mysterious organ. It can be troublesome specimen for surgical pathologist due to discordance between patient’s clinical condition and perceived finding. The weight of spleen is about 150 grams and lies beneath 9th to 12th thoracic rib in healthy adult and between fundus of stomach & diaphragm. It composed of red pulp (76-79% and white pulp (5-20% which are separated by marginal zone. A total of 100 cases were studied at histopathology section of our laboratory during the period of January 2015 to December 2015. The specimens were received in 10% neutral buffer formalin with duly filled request form. All specimens were examined macroscopically. After routine processing the sections were stained with routine haematoxylin and eosin stain. The most common age group to be affected is 3rd decade (29%, next was 4th decade (23% with slightly male predominance. Male: female ratio is 1.3:1. Most common cause for splenectomy was portal hypertension (33% followed by trauma (15%. Most common microscopic finding is fibrocongestive splenomegaly (68% which is correlated with clinical and radiological finding. In adult Portal hypertension as a hepatic cause and in paediatric age group thalassemia is the most common indication for splenectomy.

  19. [The in vitro antifungal activities of fluconazole against pathogenic yeasts recently isolated from clinical specimens].

    Science.gov (United States)

    Yamaguchi, H; Igari, J; Kume, H; Abe, M; Oguri, T; Kanno, H; Kawakami, S; Okuzumi, K; Fukayama, M; Ito, A; Kawata, K; Uchida, K

    1997-09-01

    The emergence of Candida albicans resistance to azole antifungal agents have been reported in the U. S. and Europe. We examined the in vitro antifungal activities of fluconazole against clinical isolates collected by seven investigators in three years to examine if a tendency existed toward the development of azole-resistance among fungal isolates in Japan. The following results were obtained: 1. Sensitivities to fluconazole (FLCZ) were determined for yeast-like fungi, including 113 strains isolated in 1993, 149 strains isolated in 1994 and 205 strains isolated in 1995. No significant differences in sensitivities in the three years were detected. 2. Minimum inhibitory concentrations of FLCZ were 0.1-0.78 microgram/ml for C. albicans and 3.13-25 micrograms/ml for C. glabrata. Strains with 25 micrograms/ml of FLCZ's MIC were detected; two strains of C. krusei and one strain each of C. krusei, Trichospron beigelii and Hansenula anomala. No strains with higher than 50 micrograms/ml MIC of FLCZ were detected. 3. In vitro activities of FLCZ were compared between clinical strains isolated between 1993 and 1995 and clinical strains isolated before the marketing of FLCZ (up to December 1987) or clinical yeasts isolated between 1991 and 1992. No significant differences were observed, suggesting that no tendency existed toward azole resistance among fungal strains examined.

  20. Measurements and Counts for Notacanthidae Specimens

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Taxonomic data were collected for specimens of deep-sea spiny eels (Notacanthidae) from the Hawaiian Ridge by Bruce C. Mundy. Specimens were collected off the north...

  1. Notch effects in uniaxial tension specimens

    International Nuclear Information System (INIS)

    Delph, T.J.

    1979-03-01

    Results of a literature survey on the effect of notches on the time-dependent failure of uniaxial tension specimens at elevated temperatures are presented. Particular attention is paid to the failure of notched specimens containing weldments

  2. Analysis of ductile-brittle transition shifts for standard and miniature bending specimens of irradiated steel

    International Nuclear Information System (INIS)

    Korshunov, M.E.; Korolev, Yu.N.; Krasikov, E.A.; Gabuev, N.N.; Tykhmeev, D.Yu.

    1996-01-01

    A study is made to reveal if there is a correlation between shifts in temperature curves obtained when testing thin plates and standard specimens on impact bending and fracture toughness. The tests were carried out using steel 25Kh3NM specimens irradiated by 6 x 10 19 cm -2 neutron fluence. A conclusion is made about the possibility to evaluate the degree of radiation-induced embrittlement of reactor steels on the basis of thin plate testing under quasistatic loads [ru

  3. Technique of manufacturing specimen of irradiated fuel rods

    International Nuclear Information System (INIS)

    Min, Duck Seok; Seo, Hang Seok; Min, Duck Kee; Koo, Dae Seo; Lee, Eun Pyo; Yang, Song Yeol

    1999-04-01

    Technique of manufacturing specimen of irradiated fuel rods to perform efficient PIE is developed by analyzing the relation between requiring time of manufacturing specimen and manufacturing method in irradiated fuel rods. It takes within an hour to grind 1 mm of specimen thickness under 150 rpm in speed of grinding, 600 g gravity in force using no.120, no.240, no.320 of grinding paper. In case of no.400 of grinding paper, it takes more an hour to grind the same thickness as above. It takes up to a quarter to grind 80-130 μm in specimen thickness using no.400 of grinding paper. When grinding time goes beyond 15 minutes, the grinding thickness of specimen does not exist. The polishing of specimen with 150 Rpms in speed of grinding machine, 600 g gravity in force, 10 minutes in polishing time using diamond paste 15 μm on polishing cloths amounts to 50 μm in specimen thickness. In case of diamond paste 9 μm on polishing cloth, the polishing of specimen amounts to 20 μm. The polishing thickness of specimen with 15 minutes in polishing time using 6 μm, 3 μm, 1 μm, 1/4 μm does not exist. Technique of manufacturing specimen of irradiated fuel rods will have application to the destructive examination of PIE. (author). 6 refs., 1 tab., 10 figs

  4. Epidemiology, Clinical Characteristics, and Antimicrobial Susceptibility Profiles of Human Clinical Isolates of Staphylococcus intermedius Group.

    Science.gov (United States)

    Yarbrough, Melanie L; Lainhart, William; Burnham, C A

    2018-03-01

    The veterinary pathogens in the Staphylococcus intermedius group (SIG) are increasingly recognized as causes of human infection. Shared features between SIG and Staphylococcus aureus may result in the misidentification of SIG in human clinical cultures. This study examined the clinical and microbiological characteristics of isolates recovered at a tertiary-care academic medical center. From 2013 to 2015, 81 SIG isolates were recovered from 62 patients. Patients were commonly ≥50 years old, diabetic, and/or immunocompromised. Documentation of dog exposure in the electronic medical record was not common. Of the 81 SIG isolates, common sites of isolation included 37 (46%) isolates from wound cultures and 17 (21%) isolates from respiratory specimens. Although less common, 10 (12%) bloodstream infections were documented in 7 unique patients. The majority of SIG (65%) isolates were obtained from polymicrobial cultures. In comparison to S. aureus isolates from the same time period, significant differences were noted in proportion of SIG isolates that were susceptible to doxycycline (74% versus 97%, respectively; P SIG isolates. All MR isolates detected by an oxacillin disk diffusion test would have been misclassified as methicillin susceptible using a cefoxitin disk diffusion test. Thus, SIG is recovered from human clinical specimens, and distinction of SIG from S. aureus is critical for the accurate characterization of MR status in these isolates. Copyright © 2018 American Society for Microbiology.

  5. Obtain ceramic porous alumina-zirconia by replica method calcium phosphate coated

    International Nuclear Information System (INIS)

    Silva, A.D.R.; Rigoli, W.R.; Osiro, Denise; Pallone, E.M.J.A.

    2016-01-01

    Biomaterials used in bone replacement, including porous bioceramics, are often used as support structure for bone formation and repair. The porous bioceramics are used because present features as biocompatibility, high porosity and pore morphology that confer adequate mechanical strength and induce bone growth. In this work were obtained porous specimens of alumina containing 5% by inclusion of volume of zirconia produced by the replica method. The porous specimens had its surface chemically treated with phosphoric acid and were coated with calcium phosphate. The coating was performed using the biomimetic method during 14 days and an initial pH of 6.1. The porous specimens were characterized using the follow techniques: porosity, axial compression tests, microtomography, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and pH measurements SBF solution. The results showed specimens with suitable pore morphology for application as biomaterial, and even a reduced time of incubation favored the calcium phosphate phases formation on the material surfaces. (author)

  6. Specimen loading list for the varying temperature experiment

    International Nuclear Information System (INIS)

    Qualls, A.L.; Sitterson, R.G.

    1998-01-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report

  7. Radiation damage relative to transmission electron microscopy of biological specimens at low temperature: a review

    International Nuclear Information System (INIS)

    Glaeser, R.M.; Taylor, K.A.

    1978-01-01

    When biological specimens are irradiated by the electron beam in the electron microscope, the specimen structure is damaged as a result of molecular excitation, ionization, and subsequent chemical reactions. The radiation damage that occurs in the normal process of electron microscopy is known to present severe limitations for imaging high resolution detail in biological specimens. The question of radiation damage at low temperatures has therefore been investigated with the view in mind of reducing somewhat the rate at which damage occurs. The radiation damage protection found for small molecule (anhydrous) organic compounds is generally rather limited or even non-existent. However, large molecule, hydrated materials show as much as a 10-fold reduction at low temperature in the rate at which radiation damage occurs, relative to the damage rate at room temperature. In the case of hydrated specimens, therefore, low temperature electron microscopy offers an important advantage as part of the overall effort required in obtaining high resolution images of complex biological structures. (author)

  8. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  9. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  10. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    Science.gov (United States)

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    were obtained with normalization by both the computer estimated and pathologist estimated epithelium percentage. Our results show that estimation of tissue epithelium percentage using our color-based segmentation method correlates well with pathologists' estimation of tissue epithelium percentages. The epithelium contents estimated by color-based segmentation may be useful in immuno-based analysis or clinical proteomic analysis of tumor proteins. The codes used for epithelium estimation as well as the micrographs with estimated epithelium content are available online.

  11. Concordance of DNA methylation profiles between breast core biopsy and surgical excision specimens containing ductal carcinoma in situ (DCIS).

    Science.gov (United States)

    Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C

    2017-08-01

    The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all Pcore biopsy and surgical specimens, 15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  13. Limited Utility of Polymerase Chain Reaction in Induced Sputum Specimens for Determining the Causes of Childhood Pneumonia in Resource-Poor Settings: Findings From the Pneumonia Etiology Research for Child Health (PERCH) Study.

    Science.gov (United States)

    Thea, Donald M; Seidenberg, Phil; Park, Daniel E; Mwananyanda, Lawrence; Fu, Wei; Shi, Qiyuan; Baggett, Henry C; Brooks, W Abdullah; Feikin, Daniel R; Howie, Stephen R C; Knoll, Maria Deloria; Kotloff, Karen L; Levine, Orin S; Madhi, Shabir A; O'Brien, Katherine L; Scott, J Anthony G; Antonio, Martin; Awori, Juliet O; Baillie, Vicky L; DeLuca, Andrea N; Driscoll, Amanda J; Higdon, Melissa M; Hossain, Lokman; Jahan, Yasmin; Karron, Ruth A; Kazungu, Sidi; Li, Mengying; Moore, David P; Morpeth, Susan C; Ofordile, Ogochukwu; Prosperi, Christine; Sangwichian, Ornuma; Sawatwong, Pongpun; Sylla, Mamadou; Tapia, Milagritos D; Zeger, Scott L; Murdoch, David R; Hammitt, Laura L

    2017-06-15

    Sputum examination can be useful in diagnosing the cause of pneumonia in adults but is less well established in children. We sought to assess the diagnostic utility of polymerase chain reaction (PCR) for detection of respiratory viruses and bacteria in induced sputum (IS) specimens from children hospitalized with severe or very severe pneumonia. Among children aged 1-59 months, we compared organism detection by multiplex PCR in IS and nasopharyngeal/oropharyngeal (NP/OP) specimens. To assess whether organism presence or density in IS specimens was associated with chest radiographic evidence of pneumonia (radiographic pneumonia), we compared prevalence and density in IS specimens from children with radiographic pneumonia and children with suspected pneumonia but without chest radiographic changes or clinical or laboratory findings suggestive of pneumonia (nonpneumonia group). Among 4232 cases with World Health Organization-defined severe or very severe pneumonia, we identified 1935 (45.7%) with radiographic pneumonia and 573 (13.5%) with nonpneumonia. The organism detection yield was marginally improved with IS specimens (96.2% vs 92.4% for NP/OP specimens for all viruses combined [P = .41]; 96.9% vs 93.3% for all bacteria combined [P = .01]). After accounting for presence in NP/OP specimens, no organism was detected more frequently in the IS specimens from the radiographic pneumonia compared with the nonpneumonia cases. Among high-quality IS specimens, there were no statistically significant differences in organism density, except with cytomegalovirus, for which there was a higher quantity in the IS specimens from cases with radiographic pneumonia compared with the nonpneumonia cases (median cycle threshold value, 27.9 vs 28.5, respectively; P = .01). Using advanced molecular methods with IS specimens provided little additional diagnostic information beyond that obtained with NP/OP swab specimens. © The Author 2017. Published by Oxford University Press for the

  14. An Experimental Study of the Fracture Coalescence Behaviour of Brittle Sandstone Specimens Containing Three Fissures

    Science.gov (United States)

    Yang, S. Q.; Yang, D. S.; Jing, H. W.; Li, Y. H.; Wang, S. Y.

    2012-07-01

    To analyse the fracture coalescence behaviour of rock, rectangular prismatic sandstone specimens (80 × 160 × 30 mm in size) containing three fissures were tested under uniaxial compression. The strength and deformation behaviours of the specimens are first analysed by investigating the effects of the ligament angle β2 on the peak strength, peak strain and crack initiation stress of the specimens. To confirm the sequence of crack coalescence, a photographic monitoring technique is used throughout the entire period of deformation. Based on the results, the relationship between the real-time crack coalescence process and the axial stress-strain curve of brittle sandstone specimens is also developed, and this relationship can be used to evaluate the macroscopic deformation characteristics of pre-cracked rock. The equivalent strain evolution fields of the specimen, with α = β1 = 45° and β2 = 90°, are obtained using the digital image correlation technique and show good agreement with the experimental results of pre-cracked brittle sandstone. These experimental results are expected to improve the understanding of fracture mechanisms and be used in rock engineering with intermittent structures, such as deep underground excavated tunnels.

  15. High purity of human oligodendrocyte progenitor cells obtained from neural stem cells: suitable for clinical application.

    Science.gov (United States)

    Wang, Caiying; Luan, Zuo; Yang, Yinxiang; Wang, Zhaoyan; Wang, Qian; Lu, Yabin; Du, Qingan

    2015-01-30

    Recent studies have suggested that the transplantation of oligodendrocyte progenitor cells (OPCs) may be a promising potential therapeutic strategy for a broad range of diseases affecting myelin, such as multiple sclerosis, periventricular leukomalacia, and spinal cord injury. Clinical interest arose from the potential of human stem cells to be directed to OPCs for the clinical application of treating these diseases since large quantities of high quality OPCs are needed. However, to date, there have been precious few studies about OPC induction from human neural stem cells (NSCs). Here we successfully directed human fetal NSCs into highly pure OPCs using a cocktail of basic fibroblast growth factor, platelet-derived growth factor, and neurotrophic factor-3. These cells had typical morphology of OPCs, and 80-90% of them expressed specific OPC markers such as A2B5, O4, Sox10 and PDGF-αR. When exposed to differentiation medium, 90% of the cells differentiated into oligodendrocytes. The OPCs could be amplified in our culture medium and passaged at least 10 times. Compared to a recent published method, this protocol had much higher stability and repeatability, and OPCs could be obtained from NSCs from passage 5 to 38. It also obtained more highly pure OPCs (80-90%) via simpler and more convenient manipulation. This study provided an easy and efficient method to obtain large quantities of high-quality human OPCs to meet clinical demand. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A mechanical microcompressor for high resolution imaging of motile specimens

    OpenAIRE

    Zinskie, Jessica A.; Shribak, Michael; Bruist, Michael F.; Aufderheide, Karl J.; Janetopoulos, Chris

    2015-01-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differenti...

  17. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  18. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  19. Study of deformation evolution during failure of rock specimens using laser-based vibration measurements

    Science.gov (United States)

    Smolin, I. Yu.; Kulkov, A. S.; Makarov, P. V.; Tunda, V. A.; Krasnoveikin, V. A.; Eremin, M. O.; Bakeev, R. A.

    2017-12-01

    The aim of the paper is to analyze experimental data on the dynamic response of the marble specimen in uniaxial compression. To make it we use the methods of mathematical statistics. The lateral surface velocity evolution obtained by the laser Doppler vibrometer represents the data for analysis. The registered data were regarded as a time series that reflects deformation evolution of the specimen loaded up to failure. The revealed changes in statistical parameters were considered as precursors of failure. It is shown that before failure the deformation response is autocorrelated and reflects the states of dynamic chaos and self-organized criticality.

  20. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    Science.gov (United States)

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  1. Development of resistance welding process. 4. Preparation of pressuring enclosed creep test specimen of 7A material

    International Nuclear Information System (INIS)

    Endo, Hideo; Seki, Masayuki; Ishibashi, Fujio; Hirako, Kazuhito; Tsukada, Tatsuya

    2001-02-01

    Mechanical strength in the position welded by resistance welding system was examined in 1999. The test specimens were destroyed in the welding position in a shorter time than expected in the creep test. Therefore, test specimens were prepared to evaluate the cause of destruction. Inner-pressure enclosed creep test specimens were prepared by resistance welding method. Cladding material with low deviation of thickness and high re-crystallization rate was used. Heat treatment after resistance welding was performed to remove the influence of residual stress and the precipitation of carbides. (1) Before preparation of specimens, the welding condition was fixed. Three test specimens were prepared. Two specimens without heat treatment were transported to MMS in Oarai Engineering Center on Aug. 4, 2000. One specimen with heat treatment was transported to MMS after evaluating the residual stress to get optimum heat treatment condition. (2) Specimens were prepared with welding end plugs to both ends of ferritic ODS cladding. Enclosing sides were welded with highly strong Ferritic/Martensitic steel end plugs. The other sides were welded with ferritic ODS end plugs. (3) Some kinds of electrical wave data were obtained during performing welding. Welding position was evaluated with supersonic detector after performing welding. (4) Mechanical strength of welding position in high temperature 800degC was confirmed to be equal to or larger than that of cladding material. The highly qualified specimens in the present were successfully prepared. (author)

  2. A Century of Shope Papillomavirus in Museum Rabbit Specimens.

    Directory of Open Access Journals (Sweden)

    Clara Escudero Duch

    Full Text Available Sylvilagus floridanus Papillomavirus (SfPV causes growth of large horn-like tumors on rabbits. SfPV was described in cottontail rabbits (probably Sylvilagus floridanus from Kansas and Iowa by Richard Shope in 1933, and detected in S. audubonii in 2011. It is known almost exclusively from the US Midwest. We explored the University of Kansas Natural History Museum for historical museum specimens infected with SfPV, using molecular techniques, to assess if additional wild species host SfPV, and whether SfPV occurs throughout the host range, or just in the Midwest. Secondary aims were to detect distinct strains, and evidence for strain spatio-temporal specificity. We found 20 of 1395 rabbits in the KU collection SfPV symptomatic. Three of 17 lagomorph species (S. nuttallii, and the two known hosts were symptomatic, while Brachylagus, Lepus and eight additional Sylvilagus species were not. 13 symptomatic individuals were positive by molecular testing, including the first S. nuttallii detection. Prevalence of symptomatic individuals was significantly higher in Sylvilagus (1.8% than Lepus. Half of these specimens came from Kansas, though new molecular detections were obtained from Jalisco-Mexico's first-and Nebraska, Nevada, New Mexico, and Texas, USA. We document the oldest lab-confirmed case (Kansas, 1915, pre-dating Shope's first case. SfPV amplification was possible from 63.2% of symptomatic museum specimens. Using multiple methodologies, rolling circle amplification and, multiple isothermal displacement amplification in addition to PCR, greatly improved detection rates. Short sequences were obtained from six individuals for two genes. L1 gene sequences were identical to all previously detected sequences; E7 gene sequences, were more variable, yielding five distinct SfPV1 strains that differing by less than 2% from strains circulating in the Midwest and Mexico, between 1915 and 2005. Our results do not clarify whether strains are host species

  3. 7 CFR 97.8 - Specimen requirements.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Specimen requirements. 97.8 Section 97.8 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... required by the examiner to furnish representative specimens of the variety, or its flower, fruit, or seeds...

  4. SEM-analysis of grain boundary porosity in three S-176 specimens

    International Nuclear Information System (INIS)

    Malen, K.; Birath, S.; Mattsson, O.

    1980-10-01

    Porosity in UO 2 -fuel has been studied in scanning electron microscope (SEM). The aim was to obtain a basis for evaluation of porosity in high burnup power reactor fuel. Three specimens have been analyzed. In the high temperature zones porosity can be seen both on grain boundaries and at grain edges. In the low temperature regions very little changes seem to have occurred during irradiation. (author)

  5. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  6. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  7. Can Unmanned Aerial Systems (Drones Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    Directory of Open Access Journals (Sweden)

    Timothy K Amukele

    Full Text Available Unmanned Aerial Systems (UAS or drones could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests.Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total: two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results.Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal, was 97%. Length of flight had no impact on the results.Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  8. Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    Science.gov (United States)

    Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff

    2015-01-01

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  9. Use of the strength ratio for pre-cracked Charpy specimens for the measuring, of the dynamic toughness of steels

    International Nuclear Information System (INIS)

    Pereira, L.C.; Darwish, F.A.I.

    1981-01-01

    The specimen strength ratio (R sub(sb)) determined for precraked Charpy specimens fractured in dynamic bending was correlated with plane strain fracture toughness (K sub(Id)) obtained through valid measurements of the J-integral at the moment of fracture initiation in various microstructures of the AISI 4140 steel. The results indicate a linear relationship between K sub(Id) and R sub(sb) for the microstructures considered in this work. The range of validity of this linear correlation is presented and discussed in terms of the ASTM E399 specimen size criterion. (Author) [pt

  10. Intraoperative digital specimen radiography in the treatment of nonpalpable breast lesions

    Directory of Open Access Journals (Sweden)

    Vicko Ferenc

    2017-01-01

    Full Text Available Introduction/Objective. About a third of the breast lesions on mammography are clinically occult. The goals of surgical treatment are to locate, remove, and verify their presence in the removed breast tissue. Standard specimen mammography (SSM has been an official procedure for the latter, while intraoperative digital specimen radiography (IDSR was introduced recently. The aim of this study was to evaluate the use of IDSR versus SSM and possible benefits regarding the duration of the procedures (operating room occupancy, availability of digital mammography for additional number of patients, surgeon productivity, and the quality of performed services. Methods. A retrospective chart review of 109 patients who underwent IDSR for nonpalpable breast lesions was performed between January 2014 and June 2016. We compared the difference in the duration of IDSR versus SSM procedure. We also observed the number of re-excisions and evaluated time-saving in the operating room workflow. Results. The average duration of surgery in the IDSR group of patients was 51 minutes, compared to 64 minutes in the SSM group. Every IDSR procedure saved 13 minutes over the standard SSM. That would allow another 28 procedures in the same time frame, with the same quality of service compared with SSM. In that way we increased productivity by 27.5%. Additional operation/surgery was needed for histologically involved surgical margins in three cases (2.75%. Conclusion. The use of new technology resulted in the rationalization of the operative room workflow and gave better productivity. More savings were obtained through the increase of digital mammography capacity for diagnostics, decrease of anesthesia duration, and better management of human resources. The number of “true” re-excisions, involving additional surgery, remained similar after introducing IDSR.

  11. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    DEFF Research Database (Denmark)

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  12. Closeout of JOYO-1 Specimen Fabrication Efforts

    International Nuclear Information System (INIS)

    ME Petrichek; JL Bump; RF Luther

    2005-01-01

    Fabrication was well under way for the JOYO biaxial creep and tensile specimens when the NR Space program was canceled. Tubes of FS-85, ASTAR-811C, and T-111 for biaxial creep specimens had been drawn at True Tube (Paso Robles, CA), while tubes of Mo-47.5 Re were being drawn at Rhenium Alloys (Cleveland, OH). The Mo-47.5 Re tubes are now approximately 95% complete. Their fabrication and the quantities produced will be documented at a later date. End cap material for FS-85, ASTAR-811C, and T-111 had been swaged at Pittsburgh Materials Technology, Inc. (PMTI) (Large, PA) and machined at Vangura (Clairton, PA). Cutting of tubes, pickling, annealing, and laser engraving were in process at PMTI. Several biaxial creep specimen sets of FS-85, ASTAR-811C, and T-111 had already been sent to Pacific Northwest National Laboratory (PNNL) for weld development. In addition, tensile specimens of FS-85, ASTAR-811C, T-111, and Mo-47.5 Re had been machined at Kin-Tech (North Huntington, PA). Actual machining of the other specimen types had not been initiated. Flowcharts 1-3 detail the major processing steps each piece of material has experienced. A more detailed description of processing will be provided in a separate document [B-MT(SRME)-51]. Table 1 lists the in-process materials and finished specimens. Also included are current metallurgical condition of these materials and specimens. The available chemical analyses for these alloys at various points in the process are provided in Table 2

  13. Building Connecticut's clinical biodosimetry laboratory surge capacity to mitigate the health consequences of radiological and nuclear disasters: A collaborative approach between the state biodosimetry laboratory and Connecticut's medical infrastructure

    International Nuclear Information System (INIS)

    Albanese, Joseph; Martens, Kelly; Arnold, Jeffrey L.; Kelley, Katherine; Kristie, Virginia; Forte, Elaine; Schneider, Mark; Dainiak, Nicholas

    2007-01-01

    Biodosimetry, based on the analysis of dicentric chromosomes in circulating mononuclear cells, is considered the 'gold standard' for estimating radiation dose and is used to make informed decisions regarding the medical management of irradiated persons. This paper describes the development of biodosimetry laboratory surge capacity for the health consequences of radiological and nuclear disasters in Connecticut, including: (1) establishment of the Biodosimetry Laboratory for the timely assessment of radiation dosage in biodosimetry specimens; (2) identification of clinical laboratories qualified and willing to process biodosimetry specimens from a large number of victims; (3) training of clinical laboratorians in initial biodosimetry specimen processing; and (4) conducting a functional drill that evaluated the effectiveness of these elements. Descriptive information was obtained from: (1) personal observations; (2) a needs assessment of clinical laboratories in Connecticut; (3) records from a training program of clinical laboratorians in biodosimetry specimen processing that was developed and provided by the Yale New Haven Center for Emergency Preparedness and Disaster Response; and (4) records from a statewide functional drill in biodosimetry specimen processing that was developed and conducted by the State of Connecticut Biodosimetry Laboratory. A needs assessment of clinical laboratories in Connecticut identified 30 of 32 clinical laboratories qualified and willing to perform initial biodosimetry specimen processing. Currently, 79 clinical laboratorians in 19 of these qualified clinical laboratories have been trained in biodosimetry specimen processing. A functional exercise was conducted involving 37 of these trained clinical laboratorians in 18 qualified laboratories as well as the Biodosimetry Laboratory. The average turnaround time for biodosimetry specimen processing in this drill was 199 min. Exercise participants provided feedback which will be used to

  14. Techniques in human airway inflammation - Quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes

    NARCIS (Netherlands)

    Aleva, RM; Kraan, J; Smith, M; ten Hacken, NHT; Postma, DS; Timens, W

    Background: In recent years, fiberoptic bronchoscopy has been introduced successfully in the research of bronchial asthma. Bronchial biopsy specimens obtained by this procedure are small, and an optimal biopsy technique is necessary to obtain high-quality tissue samples, as sufficient length of

  15. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  16. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Galicia A, J.; Francois L, J. L.; Aguilar H, F.

    2015-09-01

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO 3 ) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10 18 n/cm 2 , which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  17. Evaluation of a multiplex real-time PCR assay for the detection of respiratory viruses in clinical specimens.

    Science.gov (United States)

    Rheem, Insoo; Park, Joowon; Kim, Tae-Hyun; Kim, Jong Wan

    2012-11-01

    In this study, we evaluated the analytical performance and clinical potential of a one-step multiplex real-time PCR assay for the simultaneous detection of 14 types of respiratory viruses using the AdvanSure RV real-time PCR Kit (LG Life Sciences, Korea). Three hundred and twenty clinical specimens were tested with the AdvanSure RV real-time PCR Kit and conventional multiplex reverse transcription (RT)-PCR assay. The assay results were analyzed and the one-step AdvanSure RV real-time PCR Kit was compared with the conventional multiplex RT-PCR assay with respect to the sensitivity and specificity of the detection of respiratory viruses. The limit of detection (LOD) was 1.31 plaque-forming units (PFU)/mL for human rhinoviruses (hRVs), 4.93 PFU/mL for human coronavirus HCoV-229E/NL63, 2.67 PFU/mL for human coronavirus HCoV-OC43, 18.20 PFU/mL for parainfluenza virus 1 (PIV)-1, 24.57 PFU/mL for PIV-2, 1.73 PFU/mL for PIV-3, 1.79 PFU/mL for influenza virus group (Flu) A, 59.51 PFU/mL for FluB, 5.46 PFU/mL for human respiratory syncytial virus (hRSV)-A, 17.23 PFU/mL for hRSV-B, 9.99 PFU/mL for human adenovirus (ADVs). The cross-reactivity test for this assay against 23 types of non-respiratory viruses showed negative results for all viruses tested. The agreement between the one-step AdvanSure multiplex real-time PCR assay and the conventional multiplex RT-PCR assay was 98%. The one-step AdvanSure RV multiplex real-time PCR assay is a simple assay with high potential for specific, rapid and sensitive laboratory diagnosis of respiratory viruses compared to conventional multiplex RT-PCR.

  18. Simultaneous specimen and stage cleaning device for analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nestor J.

    1996-01-01

    An improved method and apparatus are provided for cleaning both a specimen stage, a specimen and an interior of an analytical electron microscope (AEM). The apparatus for cleaning a specimen stage and specimen comprising a plasma chamber for containing a gas plasma and an air lock coupled to the plasma chamber for permitting passage of the specimen stage and specimen into the plasma chamber and maintaining an airtight chamber. The specimen stage and specimen are subjected to a reactive plasma gas that is either DC or RF excited. The apparatus can be mounted on the analytical electron microscope (AEM) for cleaning the interior of the microscope.

  19. Observation particle morphology of colloidal system by conventional SEM with an improved specimen preparation technique.

    Science.gov (United States)

    Xu, Jing; Hou, Zhaosheng; Yuan, Xiaojiao; Guo, Hong

    2011-08-01

    On the basis of our previous report that polymer emulsion with different viscosity can be investigated by conventional scanning electron microscopy (SEM), we have developed an improved specimen preparation technique for obtaining particle morphology and size of colloidal silver, collagen, glutin, and polymer microspheres. In this study, we expect to provide a means for charactering the three-dimensional surface microstructure of colloidal particles. Dilution of the samples with appropriate volatile solvent like ethanol is effective for SEM specimen preparation. At a proper ratio between sample and ethanol, the colloidal particles are dispersed uniformly in ethanol and then deposited evenly on the substrate. Different drying methods are studied to search a proper drying condition, in which the small molecule solvent is removed without destroying the natural particle morphology. And the effects of ethanol in the specimen preparation process are described by analyzing the physicochemical properties of ethanol. The specimen preparation technique is simple and can be achieved in common laboratory for charactering the particle morphology of colloidal system. Copyright © 2010 Wiley-Liss, Inc.

  20. Evaluation of BacT/Alert 3D Liquid Culture System for Recovery of Mycobacteria from Clinical Specimens Using Sodium Dodecyl (Lauryl) Sulfate-NaOH Decontamination

    Science.gov (United States)

    Carricajo, A.; Fonsale, N.; Vautrin, A. C.; Aubert, G.

    2001-01-01

    A total of 52 mycobacterial isolates were recovered from 1,197 clinical specimens decontaminated by a sodium dodecyl (lauryl) sulfate (SDS)-NaOH protocol. Of these, 94% were recovered with the BacT/Alert 3D system (Organon Teknika, Durham, N.C.) and 79% were recovered on Löwenstein-Jensen (LJ) medium. Mean times to detection of organisms of the Mycobacterium tuberculosis complex (n = 47) were 22.8 days with LJ medium and 16.2 days with the system. The BacT/Alert 3D system is a rapid and efficient detection system which can be used with an SDS-NaOH decontamination procedure. PMID:11574623

  1. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    Science.gov (United States)

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. Effect of postmortem sampling technique on the clinical significance of autopsy blood cultures.

    Science.gov (United States)

    Hove, M; Pencil, S D

    1998-02-01

    Our objective was to investigate the value of postmortem autopsy blood cultures performed with an iodine-subclavian technique relative to the classical method of atrial heat searing and antemortem blood cultures. The study consisted of a prospective autopsy series with each case serving as its own control relative to subsequent testing, and a retrospective survey of patients coming to autopsy who had both autopsy blood cultures and premortem blood cultures. A busy academic autopsy service (600 cases per year) at University of Texas Medical Branch Hospitals, Galveston, Texas, served as the setting for this work. The incidence of non-clinically relevant (false-positive) culture results were compared using different methods for collecting blood samples in a prospective series of 38 adult autopsy specimens. One hundred eleven adult autopsy specimens in which both postmortem and antemortem blood cultures were obtained were studied retrospectively. For both studies, positive culture results were scored as either clinically relevant or false positives based on analysis of the autopsy findings and the clinical summary. The rate of false-positive culture results obtained by an iodine-subclavian technique from blood drawn soon after death were statistically significantly lower (13%) than using the classical method of obtaining blood through the atrium after heat searing at the time of the autopsy (34%) in the same set of autopsy subjects. When autopsy results were compared with subjects' antemortem blood culture results, there was no significant difference in the rate of non-clinically relevant culture results in a paired retrospective series of antemortem blood cultures and postmortem blood cultures using the iodine-subclavian postmortem method (11.7% v 13.5%). The results indicate that autopsy blood cultures obtained using the iodine-subclavian technique have reliability equivalent to that of antemortem blood cultures.

  3. An Experimental Study of Shear-Dominated Failure in the 2013 Sandia Fracture Challenge Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Deibler, Lisa Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reedlunn, Benjamin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingraham, Mathew Duffy [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williams, Shelley [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    This report presents an experimental study motivated by results obtained during the 2013 Sandia Fracture Challenge. The challenge involved A286 steel, shear-dominated compression specimens whose load-deflection response contained a load maximum fol- lowed by significant displacement under decreasing load, ending with a catastrophic fracture. Blind numerical simulations deviated from the experiments well before the maximum load and did not predict the failure displacement. A series of new tests were conducted on specimens machined from the original A286 steel stock to learn more about the deformation and failure processes in the specimen and potentially improve future numerical simulations. The study consisted of several uniaxial tension tests to explore anisotropy in the material, and a set of new tests on the compression speci- men. In some compression specimen tests, stereo digital image correlation (DIC) was used to measure the surface strain fields local to the region of interest. In others, the compression specimen was loaded to a given displacement prior to failure, unloaded, sectioned, and imaged under the microscope to determine when material damage first appeared and how it spread. The experiments brought the following observations to light. The tensile tests revealed that the plastic response of the material is anisotropic. DIC during the shear- dominated compression tests showed that all three in-plane surface strain components had maxima in the order of 50% at the maximum load. Sectioning of the specimens revealed no signs of material damage at the point where simulations deviated from the experiments. Cracks and other damage did start to form approximately when the max- imum load was reached, and they grew as the load decreased, eventually culminating in catastrophic failure of the specimens. In addition to the steel specimens, a similar study was carried out for aluminum 7075-T651 specimens. These specimens achieved much lower loads and displacements

  4. DNA damage in preserved specimens and tissue samples: a molecular assessment

    Directory of Open Access Journals (Sweden)

    Cantin Elizabeth

    2008-10-01

    Full Text Available Abstract The extraction of genetic information from preserved tissue samples or museum specimens is a fundamental component of many fields of research, including the Barcode of Life initiative, forensic investigations, biological studies using scat sample analysis, and cancer research utilizing formaldehyde-fixed, paraffin-embedded tissue. Efforts to obtain genetic information from these sources are often hampered by an inability to amplify the desired DNA as a consequence of DNA damage. Previous studies have described techniques for improved DNA extraction from such samples or focused on the effect of damaging agents – such as light, oxygen or formaldehyde – on free nucleotides. We present ongoing work to characterize lesions in DNA samples extracted from preserved specimens. The extracted DNA is digested to single nucleosides with a combination of DNase I, Snake Venom Phosphodiesterase, and Antarctic Phosphatase and then analyzed by HPLC-ESI-TOF-MS. We present data for moth specimens that were preserved dried and pinned with no additional preservative and for frog tissue samples that were preserved in either ethanol, or formaldehyde, or fixed in formaldehyde and then preserved in ethanol. These preservation methods represent the most common methods of preserving animal specimens in museum collections. We observe changes in the nucleoside content of these samples over time, especially a loss of deoxyguanosine. We characterize the fragmentation state of the DNA and aim to identify abundant nucleoside lesions. Finally, simple models are introduced to describe the DNA fragmentation based on nicks and double-strand breaks.

  5. Significant histologic features differentiating cellular fibroadenoma from phyllodes tumor on core needle biopsy specimens.

    Science.gov (United States)

    Yasir, Saba; Gamez, Roberto; Jenkins, Sarah; Visscher, Daniel W; Nassar, Aziza

    2014-09-01

    Cellular fibroepithelial lesions (CFELs) are a heterogeneous group of tumors encompassing cellular fibroadenoma (CFA) and phyllodes tumor (PT). Distinction between the two is challenging on core needle biopsy (CNB) specimens. The objective of this study was to evaluate histologic features that can help distinguish PT from CFA on CNB specimens. Records of all patients diagnosed with CFELs on CNB specimens with follow-up excision between January 2002 and December 2012 were retrieved. Histopathologic stromal features were evaluated on CNB specimens, including mitoses per 10 high-power fields (hpf), overgrowth, increased cellularity, fragmentation, adipose tissue infiltration, heterogeneity, subepithelial condensation, and nuclear pleomorphism. Twenty-seven (42.2%) of 64 were diagnosed as PT (24 benign PTs and three borderline PTs) and 37 (57.8%) as CFA on excision. All features except for increased stromal cellularity were statistically significant. The average number of histologic features seen in PT and CFA was 3.9 and 1.4, respectively (odds ratio [OR], 7.27; 95% confidence interval [CI], 2.44-21.69; P = .0004). The average number of mitoses per 10 hpf was 3.0 for PT compared with 0.8 for CFA (OR, 2.14; 95% CI, 1.18-3.86; P = .01). The presence of mitoses (three or more) and/or total histologic features of three or more on CNB specimens were the most helpful features in predicting PT on excision. Copyright© by the American Society for Clinical Pathology.

  6. Effect of sized and specimen geometry on the initiation and propagation of the ductile fracture

    International Nuclear Information System (INIS)

    Frund, J.M.; Marini, B.; Bethmont, M.

    1994-02-01

    Strength to the fracture of the pipe in PWR has to be justified with mechanical analyses. These tests are based on the strength to ductile fracture of steels which are tested in lab. The values of resistance to fracture are obtained through tensile tests on CT specimens (determination of J-R curves). The purpose of this study is to justify the sizes of the specimens which have to be used to characterize the strength to ductile fracture of steel in secondary pipes. Tests were conducted on 0,5T-CT, 1T-CT and 2T-CT specimens. Two materials with different suffer contents were studied. The test results show that the JO,2 values gotten from the different specimens are similar. But the strength to ductile fracture in 2T-CT specimens in lower than the one measured in 0,5t-CT and 1T-CT specimens. The surface of fracture of the different specimens displays splits perpendicular to the notch and parallel to the sheet surface. These splits are produced by the separation of the manganese sulfur inclusions. The effect notes on the J-R curves seems to be relevant to these splits. The reason why these splits might be responsible for a decrease of the tearing modulus are not clearly defined up to this point. The results which have been published show the importance of the geometry effects (presence or not of lateral notches...) and the loading mode on the strength to ductile fracture. We note that the curves determined from tests on CT specimens are conservative. A few preliminary studies showed that the geometry effects on resistance to fracture can be studied and explained by using local approach methods. The Rousselier modeling is useful to explain the behaviour of ferritic steels in ductile fracture. (authors). 20 refs., 7 figs., 5 tabs

  7. Replacement/Refurbishment of JSC/NASA POD Specimens

    Science.gov (United States)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  8. The influence of specimen size on creep crack growth rate in cross-weld CT specimens cut out from a welded component

    International Nuclear Information System (INIS)

    Andersson, Peder; Segle, Peter; Samuelson, Lars Aa.

    1999-04-01

    A 3D finite element study of creep crack growth in cross-weld CT specimens with material properties of 2.25Cr1Mo at 550 deg C is carried out, where large strain and displacement theory is used. The creep crack growth rate is calculated using a creep ductility based damage model, in which the creep strain rate perpendicular to the crack plane ahead of the crack tip is integrated, considering the multiaxial stress state. The influence of specimen size on creep crack growth rate under constant load is given special attention, but the possibility to transfer results from cross-weld CT specimens to welded high temperature components is also investigated. The creep crack growth rate of a crack in a circumferentially welded pipe is compared with the creep crack growth rate of cross-weld CT specimens of three different sizes, cut out from the pipe. Although the constraint ahead of the crack tip is higher for a larger CT specimen, the creep crack growth rate is higher for a smaller specimen than for a larger one if they are loaded to attain the same stress intensity factor. If the specimens are loaded to the same C* value, however, a more complicated pattern occurs; depending on the material properties of the weldment constituents, the CT specimen with the intermediate size will either yield the highest or the lowest creep crack growth rate

  9. Fracture toughness evaluation using small specimens for assuring structural integrity of PRV's

    International Nuclear Information System (INIS)

    Lee, Bong Sang; Hong, J. H.; Chi, S. H.; Kim, J. H.; Yang, W. J.

    1999-08-01

    This report summarizes the results obtained from the three year contribution of KAERI to the IAEA-CRP on ''Assuring Structural Integrity of Reactor Pressure Vessels''. The mandatory part of this programme is to perform fracture toughness K jc tests using pre-cracked Charpy specimens on the IAEA reference material JRQ (ASTM A533-B1 steel). The results will be used to validate the small specimens for surveillance tests. In this report, three different heats of reactor pressure vessel materials are characterized by the ASTM E 1921-97 s tandard test method for determination of reference temperature, T o , for ferritic steels in the transition range . The materials are the IAEA reference plate (JRQ), a Japanese forging (JEL), and a Korean forging (KFY5). 6 refs., 7 tabs., 20 figs

  10. Development of laser plasma x-ray microscope for living hydrated biological specimens

    International Nuclear Information System (INIS)

    Kado, Masataka; Daido, Hiroyuki

    2005-01-01

    Investigating the structure and the function of life object performing advanced life activity becomes important. In order to investigate the life object, it is necessary to observe living specimens with high spatial resolution and high temporal resolution. Since laser plasma x-ray source has high brightness and short pulse duration, x-ray microscope with the laser plasma x-ray source makes possible to observe living specimens. Such as chromosomes, macrophages, bacterium, and so on have been observed by contact x-ray microscopy. The x-ray images obtained by indirect measurements such as the contact x-ray microscopy have difficulty to avoid artificial effect such as irregular due to developing process. Development of an x-ray microscope with laser plasma x-ray source is necessary to avoid such defects. (author)

  11. Recommendations for Pathologic Evaluation of Reduction Mammoplasty Specimens: A Prospective Study With Systematic Tissue Sampling.

    Science.gov (United States)

    Ambaye, Abiy B; Goodwin, Andrew J; MacLennan, Susan E; Naud, Shelly; Weaver, Donald L

    2017-11-01

    - Breast reduction mammaplasty (RMP) for symptomatic macromastia or correction of asymmetry is performed in more than 100 000 patients per year in the United States. The reported incidence of significant pathologic findings (SPF), that is, carcinoma and atypical hyperplasia, ranges from 0.06% to 12.8%. No standard pathology assessment for RMP exists. - To propose standard sampling for microscopic evaluation in RMP specimens, to evaluate the incidence of occult carcinoma and atypical hyperplasia, and to identify clinical risk factors for SPF in patients undergoing RMP. - All RMP specimens from 2006 to 2013 at a single institution were prospectively examined. After baseline gross and microscopic evaluations, each specimen was subjected to systematic additional sampling. The incidence of SPF was tabulated, and variables such as age, specimen weight, previous history of SPF, and results of preoperative mammogram were examined. Clinical follow-up review was also subsequently undertaken. - A total of 595 patients were evaluated. Significant pathologic findings were present in 9.8% (58 of 595) of patients. No cancer was identified in patients younger than 40 years; the rates of carcinoma were 2.4% (14 of 595) in all patients, 3.6% (14 of 392) in patients aged 40 years or older, and 4.3% (10 of 233) in patients aged 50 years or older. No carcinoma or atypical hyperplasia was identified on preoperative mammogram. Increased sampling was associated with a significantly greater frequency of SPF only in patients aged 40 years or older. - In patients younger than 35 years, gross-only evaluation is sufficient. However, increased sampling may be necessary in patients older than 40 years.

  12. Long-term follow-up of patients with a clinically benign extrahepatic biliary stenosis and K-ras mutation in endobiliary brush cytology

    NARCIS (Netherlands)

    van Heek, N. Tjarda; Rauws, Erik A. J.; Caspers, Eric; Drillenburg, Paul; Gouma, Dirk J.; Offerhaus, G. Johan A.

    2002-01-01

    Background. K-ras mutations in endobiliary brush cytology are an early event in carcinogenesis and justify a suspicion of malignancy in patients with extrahepatic biliary stenosis. However, K-ras mutations have been detected in specimens obtained by brushing of clinically benign extrahepatic biliary

  13. Clinical Evaluation of the Cepheid Xpert TV Assay for Detection of Trichomonas vaginalis with Prospectively Collected Specimens from Men and Women.

    Science.gov (United States)

    Schwebke, Jane R; Gaydos, C A; Davis, T; Marrazzo, J; Furgerson, D; Taylor, S N; Smith, B; Bachmann, L H; Ackerman, R; Spurrell, T; Ferris, D; Burnham, C A; Reno, H; Lebed, J; Eisenberg, D; Kerndt, P; Philip, S; Jordan, J; Quigley, N

    2018-02-01

    Trichomoniasis is the most prevalent curable sexually transmitted disease (STD). It has been associated with preterm birth and the acquisition and transmission of HIV. Recently, nucleic acid amplification tests (NAAT) have been FDA cleared in the United States for detection of Trichomonas vaginalis in specimens from both women and men. This study reports the results of a multicenter study recently conducted using the Xpert TV ( T. vaginalis ) assay to test specimens from both men and women. On-demand results were available in as little as 40 min for positive specimens. A total of 1,867 women and 4,791 men were eligible for inclusion in the analysis. In women, the performance of the Xpert TV assay was compared to the patient infected status (PIS) derived from the results of InPouch TV broth culture and Aptima NAAT for T. vaginalis The diagnostic sensitivities and specificities of the Xpert TV assay for the combined female specimens (urine samples, self-collected vaginal swabs, and endocervical swabs) ranged from 99.5 to 100% and 99.4 to 99.9%, respectively. For male urine samples, the diagnostic sensitivity and specificity were 97.2% and 99.9%, respectively, compared to PIS results derived from the results of broth culture for T. vaginalis and bidirectional gene sequencing of amplicons. Excellent performance characteristics were seen using both female and male specimens. The ease of using the Xpert TV assay should result in opportunities for enhanced screening for T. vaginalis in both men and women and, hopefully, improved control of this infection. Copyright © 2018 Schwebke et al.

  14. A Multiplex PCR for Detection of Mycoplasma pneumoniae, Chlamydophila pneumoniae, Legionella pneumophila, and Bordetella pertussis in Clinical Specimens

    National Research Council Canada - National Science Library

    McDonough, E. A; Barrozo, C. P; Russell, K. L; Metzgar, D

    2005-01-01

    ..., and Bordetella pertussis in uncultured patient specimens. These organisms cause similar symptomologies and are often not diagnosed because they are difficult to identify with classical methods such as culture and serology...

  15. Comparison between instrumented precracked Charpy and compact specimen tests of carbon steels

    International Nuclear Information System (INIS)

    Nanstad, R.K.

    1980-01-01

    The General Atomic Company High Temperature Gas-Cooled Reactor (HTGR) is housed within a prestressed concrete reactor vessel (PCRV). Various carbon steel structural members serve as closures at penetrations in the vessel. A program of testing and evaluation is underway to determine the need for reference fracture toughness (K/sub IR/) and indexing procedures for these materials as described in Appendix G to Section III, ASME Code for light water reactor steels. The materials of interest are carbon steel forgings (SA508, Class 1) and plates (SA537, Classes 1 and 2) as well as weldments of these steels. The fracture toughness behavior is characterized with instrumented precracked Charpy V-votch specimens (PCVN) - slow-bend and dynamic - and compact specimens (10-mm and 25-mm thicknesses) using both linear elastic (ASTM E399) and elastic-plastic (equivalent Energy and J-Integral) analytical procedures. For the dynamic PCVN tests, force-time traces are analyzed according to the procedures of the Pressure Vessel Research Council (PVRC)/Metal Properties Council (MPC). Testing and analytical procedures are discussed and PCVN results are compared to those obtained with compact specimens

  16. Production and use of plastinated anatomical specimens as teaching and learning tools in veterinary gross anatomy in the Caribbean

    Directory of Open Access Journals (Sweden)

    Reda Mohamed

    2018-03-01

    Full Text Available Objective: Veterinary Anatomy is considered as the backbone subject in the veterinary medicine program. Formalized specimens were not very much accepted by the veterinary students due to their wetness, bad smell and potential harmful effects. Plastination has evolved as a new technique for prolonged preservation of specimens by replacing the water and fat by a curable plastic polymer. Material and methods: The process of plastination involved fixation, dehydration, impregnation and curing. The plastinated specimens were used for teaching and learning of veterinary gross anatomy courses for veterinary students. Results: Plastinated specimens were appreciated by the staff and students as they were odorless, non-toxic and durable, needed less space for storage and they were used in teaching the veterinary anatomy courses. Plastinated specimens were used for studying not only in the dissection hall but also in the lecture room, both individually and in groups. Conclusion: The plastinated specimens were excellent for demonstration but they could not completely replace the traditional dissection because students learn best by exploratory and hands-on dissection. Moreover, the wet specimens provided a more accurate visual representation of the body parts and skills to aid in dealing with actual clinical cases in the future. Therefore, the plastinated and wet specimens were used simultaneously depending on the topic being taught at the time. [J Adv Vet Anim Res 2018; 5(1.000: 44-52

  17. Effects of canine parvovirus strain variations on diagnostic test results and clinical management of enteritis in dogs.

    Science.gov (United States)

    Markovich, Jessica E; Stucker, Karla M; Carr, Alaina H; Harbison, Carole E; Scarlett, Janet M; Parrish, Colin R

    2012-07-01

    To estimate the prevalence of canine parvovirus (CPV) strains among dogs with enteritis admitted to a referral hospital in the southwestern United States during an 11-month period and to compare diagnostic test results, disease severity, and patient outcome among CPV strains. Prospective observational study. 72 dogs with histories and clinical signs of parvoviral enteritis. For each dog, a fecal sample or rectal swab specimen was evaluated for CPV antigen via an ELISA. Subsequently, fecal samples (n = 42 dogs) and pharyngeal swab specimens (16) were obtained and tested for CPV antigen via an ELISA and CPV DNA via a PCR assay. For specimens with CPV-positive results via PCR assay, genetic sequencing was performed to identify the CPV strain. 56 dogs tested positive for CPV via ELISA or PCR assay. For 42 fecal samples tested via both ELISA and PCR assay, 27 had positive results via both assays, whereas 6 had positive PCR assay results only. Ten pharyngeal swab specimens yielded positive PCR assay results. Genetic sequencing was performed on 34 fecal or pharyngeal swab specimens that had CPV-positive PCR assay results; 25 (73.5%) were identified as containing CPV type-2c, and 9 (26.5%) were identified as containing CPV type-2b. No association was found between CPV strain and disease severity or clinical outcome. CPV type-2b and CPV type-2c posed similar health risks for dogs; therefore, genetic sequencing of CPV does not appear necessary for clinical management of infected patients. The diagnostic tests used could detect CPV type-2c.

  18. Timing of specimen collection is crucial in urine screening of drug dependent mothers and newborns.

    Science.gov (United States)

    Halstead, A C; Godolphin, W; Lockitch, G; Segal, S

    1988-01-01

    We compared results of urine drug analysis with clinical data and history to test the usefulness of peripartum drug screening and to establish guidelines for optimal testing. Urine from 28 mothers and 52 babies was analysed. Drugs not suspected by history were found in 10 mothers and six babies. Results assisted in the management of neonatal withdrawal in three babies. Drugs suspected by history were not found in 11/22 mothers and 23/35 babies. About half of these results were associated with delayed urine collection. In 12/28 mothers, drugs administered in hospital could have confused interpretation of screen results. We conclude that urine drug screening without strict protocols for specimen collection is of limited usefulness for management of drug abuse in pregnancy and neonatal drug withdrawal. We favour testing of maternal urine obtained before drugs are administered in hospital. Neonatal urine, if used, should be collected in the first day of life.

  19. A non-destructive DNA sampling technique for herbarium specimens.

    Science.gov (United States)

    Shepherd, Lara D

    2017-01-01

    Herbarium specimens are an important source of DNA for plant research but current sampling methods require the removal of material for DNA extraction. This is undesirable for irreplaceable specimens such as rare species or type material. Here I present the first non-destructive sampling method for extracting DNA from herbarium specimens. DNA was successfully retrieved from robust leaves and/or stems of herbarium specimens up to 73 years old.

  20. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  1. Multiple antimicrobial resistance in bacterial isolates from clinical ...

    African Journals Online (AJOL)

    A total of 545 clinical specimens (pus, blood, urine, and stool) and environmental specimens (air sample, saline solution, nasal swabs etc) were cultured for isolation and identification of aerobic bacteria and antimicrobial susceptibility testing. Out of these, 356(65%) specimens yielded one or more bacterial strains. Frequent ...

  2. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  3. Thermal neutron flux measurements in the rotary specimen rack of the IPR-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rose Mary G. do Prado; Rodrigues, Rogério R.; Souza, Luiz Claudio A., E-mail: souzarm@cdtn.br, E-mail: rrr@cdtn.br, E-mail: lcas@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The thermal neutron flux in the rotary specimen rack of the IPR-R1 TRIGA reactor at the Nuclear Technology Development Center (CDTN), Belo Horizonte, Brazil, has been measured by the neutron activation method, using bare and cadmium covered gold foils. Those foils were irradiated in the rotary specimen rack with the reactor at 100 kW. The reactor core configuration has 63 fuel elements, composed of 59 original aluminum-clad elements and 4 stainless steel-clad fuel elements. The gamma activities of the foils were measured using Ge spectrometer. The perturbations of the thermal neutron flux caused by the introduction of an absorbing foil into the medium were considered in order to obtain accurate determination of the flux. The thermal neutron flux obtained was 7.4 x 10{sup 11} n.cm{sup -2}.s{sup -1}. (author)

  4. Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).

    Science.gov (United States)

    Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P

    2015-01-01

    An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).

  5. Predicting crack instability behavior of burst tests from small specimens for irradiated Zr-2.5Nb pressure tubes

    International Nuclear Information System (INIS)

    Davies, P.H.

    1997-01-01

    A scaling approach, based on the deformation J-integral at maximum load obtained from small specimens, is proposed for predicting the crack instability behavior of burst tests on irradiated Zr-2.5Nb pressure tubes. An assessment of this approach is carried out by comparison with other toughness criteria such as the modified J-integral and the plastic work dissipation rate approach. The largest discrepancy between the different parameters occurs for materials of intermediate toughness which exhibit the most stable crack growth and tunnelling up to maximum load. A study of one material of intermediate toughness suggests crack-front tunnelling has a significant influence on the results obtained from the 17-mm-wide specimens. It is shown that for a tube of intermediate toughness the different approaches can significantly underpredict the extent of stable crack growth before instability in a burst test even after correcting for tunnelling. The usefulness of a scaling approach in reducing the discrepancy between the small- and large-scale specimen results for this material is demonstrated

  6. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  7. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  8. Dynamic Toughness Testing of Pre-Cracked Charpy V-Notch Specimens. Convention ELECTRABEL - SCK-CEN

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E

    1999-04-01

    This document describes the experimental and analytical procedures which have been adopted at the laboratories of the Belgian Nuclear Research Centre SCK-CEN for performing dynamic toughness tests on pre-cracked Charpy-V specimens. Such procedures were chosen on the basis of the existing literature on the subject, with several updates in the data analysis stages which reflect more recent developments in fracture toughness testing. Qualification tests have been carried out on PCCv specimens of JRQ steel, in order to assess the reliability of the results obtained; straightforward comparisons with reference data have been performed, as well as more advanced analyses using the Master Curve approach. Aspects related to machine compliance and dynamic tup calibration have also been addressed.

  9. Model Equation for Acoustic Nonlinear Measurement of Dispersive Specimens at High Frequency

    Science.gov (United States)

    Zhang, Dong; Kushibiki, Junichi; Zou, Wei

    2006-10-01

    We present a theoretical model for acoustic nonlinearity measurement of dispersive specimens at high frequency. The nonlinear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation governs the nonlinear propagation in the SiO2/specimen/SiO2 multi-layer medium. The dispersion effect is considered in a special manner by introducing the frequency-dependant sound velocity in the KZK equation. Simple analytic solutions are derived by applying the superposition technique of Gaussian beams. The solutions are used to correct the diffraction and dispersion effects in the measurement of acoustic nonlinearity of cottonseed oil in the frequency range of 33-96 MHz. Regarding two different ultrasonic devices, the accuracies of the measurements are improved to ±2.0% and ±1.3% in comparison with ±9.8% and ±2.9% obtained from the previous plane wave model.

  10. On the crack propagation analysis of rock like Brazilian disc specimens containing cracks under compressive line loading

    Directory of Open Access Journals (Sweden)

    Hadi Haeri

    Full Text Available The pre-existing cracks in the brittle substances seem to be the main cause of their failure under various loading conditions. In this study, a simultaneous analytical, experimental and numerical analysis of crack propagation, cracks coalescence and failure process of brittle materials has been performed. Brazilian disc tests are being carried out to evaluate the cracks propagation paths in rock-like Brazilian disc specimens containing single and double cracks (using rock-like specimens which are specially prepared from Portland Pozzolana Cement (PPC, fine sands and water in a rock mechanics laboratory. The failure load of the pre-cracked disc specimens are measured showing the decreasing effects of the cracks and their orientation on the final failure load. The same specimens are numerically simulated by a higher order indirect boundary element method known as displacement discontinuity method. These numerical results are compared with the existing analytical and experimental results proving the accuracy and validity of the proposed numerical method. The numerical and experimental results obtained from the tested specimens are in good agreement and demonstrate the accuracy and effectiveness of the proposed approach.

  11. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  12. Scanning transmission ion micro-tomography (STIM-T) of biological specimens

    International Nuclear Information System (INIS)

    Schwertner, Michael; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-01-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations

  13. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  14. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Science.gov (United States)

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  15. Experimental study on variations in Charpy impact energies of low carbon steel, depending on welding and specimen cutting method

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhaorui; Kang, Hansaem; Lee, Young Seog [Chung-Ang University, Seoul (Korea, Republic of)

    2016-05-15

    This paper presents an experimental study that examines variations of Charpy impact energy of a welded steel plate, depending upon the welding method and the method for obtaining the Charpy specimens. Flux cored arc welding (FCAW) and Gas tungsten arc welding (GTAW) were employed to weld an SA516 Gr. 70 steel plate. The methods of wire cutting and water-jet cutting were adopted to take samples from the welded plate. The samples were machined according to the recommendations of ASTM SEC. II SA370, in order to fit the specimen dimension that the Charpy impact test requires. An X-ray diffraction (XRD) method was used to measure the as-weld residual stress and its redistribution after the samples were cut. The Charpy impact energy of specimens was considerably dependent on the cutting methods and locations in the welded plate where the specimens were taken. The specimens that were cut by water jet followed by FCAW have the greatest resistance-to-fracture (Charpy impact energy). Regardless of which welding method was used, redistributed transverse residual stress becomes compressive when the specimens are prepared using water-jet cutting. Meanwhile, redistributed transverse residual stress becomes tensile when the specimens are prepared using wire cutting.

  16. Deginerative changes of femoral articular cartilage in the knee : comparative study of specimen sonography and pathology

    International Nuclear Information System (INIS)

    Park, Ju Youn; Hong, Sung Hwan; Sohn, Jin Hee; Wee, Young Hoon; Chang, Jun Dong; Park, Hong Seok; Lee, Eil Seoung; Kang Ik Won

    2001-01-01

    To determine the sonographic findings of degenerative change in femoral articular cartilage of the knee by comparative study of specimen sonography and pathology. We obtained 40 specimens of cartilage of the femur (20 medial and 20 lateral condylar) from 20 patients with osteoarthritis of the knee who had undergone total knee replacement. The specimens were placed in a saline-filled container and sonography was performed using a 10-MHz linear transducer. Sonographic abnormalities were evaluated at the cartilage surface, within the cartilage, and at the bone-cartilage interface, and were compared with the corresponding pathologic findings. In addition, cartilage thickness was measured at a representative portion of each femoral cartilage specimen and was compared with the thickness determined by sonography. 'Dot' lesions, irregularity or loss of the hyperechoic line, were demonstrated by sonography at the saline-cartilage interface of 14 cartilages. Pathologic examination showed that these findings corresponded to cleft, detachment, erosion, and degeneration. Irregularities in the hyperechoic line at the bone-cartilage interface were revealed by sonography in eight cartilages and were related to irregularity or loss of tidemark, downward displacement of the cartilage, and subchondral callus formation. Dot lesions, corresponding to cleft and degeneration, were noted within one cartilage. Cartilage thickness measured on specimen and by sonography showed no significant difference (p=0.446). Specimen sonography suggested that articular cartilage underwent degenerative histopathological change. Cartilage thickness measured by sonography exactly reflected real thickness

  17. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  18. Estimation of stress distribution in ferromagnetic tensile specimens using low cost eddy current stress measurement system and BP neural network.

    Science.gov (United States)

    Li, Jianwei; Zhang, Weimin; Zeng, Weiqin; Chen, Guolong; Qiu, Zhongchao; Cao, Xinyuan; Gao, Xuanyi

    2017-01-01

    Estimation of the stress distribution in ferromagnetic components is very important for evaluating the working status of mechanical equipment and implementing preventive maintenance. Eddy current testing technology is a promising method in this field because of its advantages of safety, no need of coupling agent, etc. In order to reduce the cost of eddy current stress measurement system, and obtain the stress distribution in ferromagnetic materials without scanning, a low cost eddy current stress measurement system based on Archimedes spiral planar coil was established, and a method based on BP neural network to obtain the stress distribution using the stress of several discrete test points was proposed. To verify the performance of the developed test system and the validity of the proposed method, experiment was implemented using structural steel (Q235) specimens. Standard curves of sensors at each test point were achieved, the calibrated data were used to establish the BP neural network model for approximating the stress variation on the specimen surface, and the stress distribution curve of the specimen was obtained by interpolating with the established model. The results show that there is a good linear relationship between the change of signal modulus and the stress in most elastic range of the specimen, and the established system can detect the change in stress with a theoretical average sensitivity of -0.4228 mV/MPa. The obtained stress distribution curve is well consonant with the theoretical analysis result. At last, possible causes and improving methods of problems appeared in the results were discussed. This research has important significance for reducing the cost of eddy current stress measurement system, and advancing the engineering application of eddy current stress testing.

  19. Evaluation of fracture toughness of vessel materials using small-size specimens and full stress-strain curves

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, A A; Chausov, N G [Akademyiya Nauk Ukrayini, Kiev (Ukraine)

    1994-12-31

    Physically substantiated dependences between crack resistance characteristics determined by the parameters of descending sections of full stress-strain curves and stressed state rigidity at crack initiation moment, have been experimentally obtained. The possibility of crack resistance reliable estimation based on full stress-strain obtained using small-size specimens with different concentrators, has thus been experimentally substantiated. Results obtained by the method and actual temperature dependence of irradiated steel 15X2NMFA crack resistance characteristics, agreed well. 2 refs., 7 figs.

  20. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  1. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    Science.gov (United States)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  2. Small specimen test technology of fracture toughness in structural material F82H steel for fusion nuclear reactors

    International Nuclear Information System (INIS)

    Wakai, Eiichi; Ohtsuka, Hideo; Jitsukawa, Shiro; Matsukawa, Shingo; Ando, Masami

    2006-03-01

    Small specimen test technology (SSTT) has been developed to investigate mechanical properties of nuclear materials. SSTT has been driven by limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources, and it is very useful for the reduction of waste materials produced in nuclear engineering. In this study new bend test machines have been developed to obtain fracture behaviors of F82H steel for very small bend specimens of pre-cracked t/2-1/3CVN (Charpy V-notch) with 20 mm-length and DFMB (deformation and fracture mini bend specimen) with 9 mm-length and disk compact tension of 0.18DCT type, and fracture behaviors were examined to evaluate DBTT (ductile-brittle transition temperature) at temperature from -180 to 25degC. The effect of specimen size on DBTT of F82H steel was also examined by using Charpy type specimens such as 1/2t-CVN, 1/3CVN and t/2-1/3CVN. In this paper, it also provides the information of the specimens irradiated at 250degC and 350degC to about 2 dpa in the capsule of 04M-67A and 04M-68A of JMTR experiments. (author)

  3. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  4. Integrative specimen information service - a campus-wide resource for tissue banking, experimental data annotation, and analysis services.

    Science.gov (United States)

    Schadow, Gunther; Dhaval, Rakesh; McDonald, Clement J; Ragg, Susanne

    2006-01-01

    We present the architecture and approach of an evolving campus-wide information service for tissues with clinical and data annotations to be used and contributed to by clinical researchers across the campus. The services provided include specimen tracking, long term data storage, and computational analysis services. The project is conceived and sustained by collaboration among researchers on the campus as well as participation in standards organizations and national collaboratives.

  5. AGC-2 Specimen Post Irradiation Data Package Report

    Energy Technology Data Exchange (ETDEWEB)

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  6. An Extended Multilocus Sequence Typing (MLST Scheme for Rapid Direct Typing of Leptospira from Clinical Samples.

    Directory of Open Access Journals (Sweden)

    Sabrina Weiss

    2016-09-01

    Full Text Available Rapid typing of Leptospira is currently impaired by requiring time consuming culture of leptospires. The objective of this study was to develop an assay that provides multilocus sequence typing (MLST data direct from patient specimens while minimising costs for subsequent sequencing.An existing PCR based MLST scheme was modified by designing nested primers including anchors for facilitated subsequent sequencing. The assay was applied to various specimen types from patients diagnosed with leptospirosis between 2014 and 2015 in the United Kingdom (UK and the Lao Peoples Democratic Republic (Lao PDR. Of 44 clinical samples (23 serum, 6 whole blood, 3 buffy coat, 12 urine PCR positive for pathogenic Leptospira spp. at least one allele was amplified in 22 samples (50% and used for phylogenetic inference. Full allelic profiles were obtained from ten specimens, representing all sample types (23%. No nonspecific amplicons were observed in any of the samples. Of twelve PCR positive urine specimens three gave full allelic profiles (25% and two a partial profile. Phylogenetic analysis allowed for species assignment. The predominant species detected was L. interrogans (10/14 and 7/8 from UK and Lao PDR, respectively. All other species were detected in samples from only one country (Lao PDR: L. borgpetersenii [1/8]; UK: L. kirschneri [1/14], L. santarosai [1/14], L. weilii [2/14].Typing information of pathogenic Leptospira spp. was obtained directly from a variety of clinical samples using a modified MLST assay. This assay negates the need for time-consuming culture of Leptospira prior to typing and will be of use both in surveillance, as single alleles enable species determination, and outbreaks for the rapid identification of clusters.

  7. Loss of high-molecular-weight cytokeratin antigenicity in prostate tissue obtained by transurethral resections

    DEFF Research Database (Denmark)

    Multhaupt, H A; Fessler, J N; Warhol, M J

    2000-01-01

    could be restored in these specimens by antigen retrieval in a low pH citrate buffer using a microwave heat technique. Keratin staining in needle biopsies and total prostatectomies was unaffected. CONCLUSION: In summary, our results indicate the technique of transurethral resection results in a specific......OBJECTIVE: Staining of prostatic basal cells for the expression of high-molecular-weight cytokeratin has been suggested as a way of distinguishing benign from malignant prostate glands. We evaluated the utility of high-molecular-weight cytokeratin in the diagnosis of malignancy in prostate...... specimens obtained in various ways. DESIGN: Prostate tissues obtained from needle biopsies, transurethral resections, and total prostatectomies were immunostained with monoclonal antibody 34betaE12, an antibody directed against high-molecular-weight cytokeratins. RESULTS: Antiserum to high...

  8. Improving ED specimen TAT using Lean Six Sigma.

    Science.gov (United States)

    Sanders, Janet H; Karr, Tedd

    2015-01-01

    Lean and Six Sigma are continuous improvement methodologies that have garnered international fame for improving manufacturing and service processes. Increasingly these methodologies are demonstrating their power to also improve healthcare processes. The purpose of this paper is to discuss a case study for the application of Lean and Six Sigma tools in the reduction of turnaround time (TAT) for Emergency Department (ED) specimens. This application of the scientific methodologies uncovered opportunities to improve the entire ED to lab system for the specimens. This case study provides details on the completion of a Lean Six Sigma project in a 1,000 bed tertiary care teaching hospital. Six Sigma's Define, Measure, Analyze, Improve, and Control methodology is very similar to good medical practice: first, relevant information is obtained and assembled; second, a careful and thorough diagnosis is completed; third, a treatment is proposed and implemented; and fourth, checks are made to determine if the treatment was effective. Lean's primary goal is to do more with less work and waste. The Lean methodology was used to identify and eliminate waste through rapid implementation of change. The initial focus of this project was the reduction of turn-around-times for ED specimens. However, the results led to better processes for both the internal and external customers of this and other processes. The project results included: a 50 percent decrease in vials used for testing, a 50 percent decrease in unused or extra specimens, a 90 percent decrease in ED specimens without orders, a 30 percent decrease in complete blood count analysis (CBCA) Median TAT, a 50 percent decrease in CBCA TAT Variation, a 10 percent decrease in Troponin TAT Variation, a 18.2 percent decrease in URPN TAT Variation, and a 2-5 minute decrease in ED registered nurses rainbow draw time. This case study demonstrated how the quantitative power of Six Sigma and the speed of Lean worked in harmony to improve

  9. Detection of iso-α-acids to confirm beer consumption in postmortem specimens.

    Science.gov (United States)

    Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H

    2015-01-01

    Iso-α-acids (IAAs) can be used as markers for the consumption of beer. Postmortem specimens from a range of coronial cases were analyzed for IAAs in order to determine the prevalence of beer consumption and any correlation to blood alcohol concentrations (BAC). A total of 130 cases were included in this study including those where beer was mentioned in the case circumstances, cases where beer was not mentioned specifically but alcohol was detected, and cases where neither beer was mentioned nor a positive BAC was present. Available blood, serum, vitreous humour and urine specimens were analyzed. Of the 50 cases where beer was mentioned, 86% had one or more IAAs detected. In cases that only had a positive BAC (n = 60), 57% of these cases also showed the presence of these beer markers. IAAs were detected in specimens obtained from traumatized, burnt, and decomposed cases with a mention of beer consumption or where BAC was positive in blood. No IAAs were detected in cases where BAC was negative. There was little or no correlation between blood IAA concentrations and BAC. This study demonstrates the possible detection of IAAs as a marker for beer consumption. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Is one sputum specimen as good as two during follow-up cultures for monitoring multi drug resistant tuberculosis patients in India?

    Directory of Open Access Journals (Sweden)

    Sharath Burugina Nagaraja

    Full Text Available BACKGROUND: In India, the Revised National Tuberculosis Control Programme (RNTCP has adopted the strategy of examining two specimens during follow-up culture examinations to monitor the treatment response of multi-drug resistant tuberculosis (MDR-TB patients. OBJECTIVES: To determine the incremental yield of the second sputum specimen during follow-up culture examinations among patients with MDR-TB and the effect on case management on changing from two to one specimen follow-up strategy. METHODS: A cross sectional record review of MDR-TB patients registered during 2008-09 under RNTCP was undertaken in three MDR-TB treatment sites of India. RESULTS: Of 1721 pairs of follow-up sputum culture examinations done among 220 MDR-TB patients, 451(26% were positive with either of the two specimens; 29(1.7% were culture positive only on the second specimen indicating the incremental yield. To detect one additional culture positive result on the second specimen, 59 specimens needed to be processed. If we had examined only one specimen, we would have missed 29 culture-positive results. By current RNTCP guidelines, however, a single specimen policy would have altered case management in only 3(0.2% instances, where patients would have missed a one month extension of the intensive phase of MDR-TB treatment. There is no meaningful advantage in using two specimens for the monitoring of MDR-TB patients. A single specimen policy could be safely implemented with negligible clinical effect on MDR-TB patients and favourable resource implications for RNTCP.

  11. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  12. The effect of specimen size on the ductile/brittle transition temperature in an A533B pressure vessel steel

    International Nuclear Information System (INIS)

    Green, G.; Knott, J.F.

    It was ascertained that it is possible to relate critical crack opening displacement (COD) values, deltasub(crit), obtained on small specimens of A 533-B pressure vessel steel to the fracture toughness value representing the initiation of fracture in a large structure. The variation of deltasub(crit) with temperature is given. A sharp increase in deltasub(crit) is observed above a temperature of approximately -100 degC and this was found to be associated with the initiation of small amounts of fibrous fracture, prior to a cleavage instability. An upper limit to the deltasub(crit) values was obtained above -50 degC, where the fracture was found to be fully ductile. Values of deltasub(crit) estimated from the valid fracture toughness results are shown for comparison. At low temperatures the estimated deltasub(crit) values are seen to be less than those measured in the small bend specimens and the sharp increase in the estimated deltasub(crit) values occurs at a higher temperature, approximately 0 degC. The room temperature deltasub(crit) value, estimated from the valid toughness results (0.15 mm) compares well with COD for the initiation of fibrous fracture, measured at the same temperature in small bend specimens (0.175 mm). The following conclusions were drawn from the experiments: 1. The ductile/brittle transition temperature, determined by critical COD measurements, is influenced by the relaxation of triaxial stresses in small specimens. 2. It is possible to relate critical COD values for the initiation of fibrous fracture, measured in small specimens, to the fracture toughness representing this behaviour in a large structure

  13. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  14. Experimental investigation of effect of specimen thickness on fracture toughness of Al-TiC composites

    Directory of Open Access Journals (Sweden)

    M. S. Raviraj

    2016-07-01

    Full Text Available In this paper, the macro and micro-mechanical fracture behavior was studied for aluminum (Al6061 alloy matrix, reinforced with various proportions of TiC particles such as 3wt%, 5wt% and 7wt%. The Al6061-TiC metal matrix composites were produced by stir casting method to ensure uniform distribution of the TiC particulates in the Al matrix. The compact tension (CT specimens were machined according to ASTM E399 specifications to evaluate the fracture toughness for Al6061-TiC metal matrix composites. The CT specimens were machined for crack to width (a/W ratio of 0.5 and thickness to width (B/W ratios of 0.2 to 0.7 with an increment of 0.1. Load versus crack mouth opening displacement (CMOD data was plotted to estimate stress intensity factor KQ for various thicknesses of the specimen. The fracture toughness KIC was obtained by plotting stress intensity factor versus thickness to width ratios of specimen data. The fracture toughness of these composites varied between 16.4-19.2 MPa√m. Scanning Electron Microscope (SEM studies was made on the fractured surface of the specimens to understand the micro-mechanisms of failure involved in these composites. Void initiation is more significant in the matrix near the interface. The micro-cracks grow from these micro-voids and crack propagates by linking these micro cracks locating the crack path preferentially in the matrix adjacent to the interface indicating ductile fracture.

  15. Ethical communication in clinical trials. Issues faced by data managers in obtaining informed consent.

    Science.gov (United States)

    Loh, Winnie Y; Butow, Phyllis N; Brown, Richard F; Boyle, Frances

    2002-12-01

    Informed consent has been proposed as the optimal method for ensuring the ethical entry of patients into clinical trials. However, it is known that problems with informed consent exist from the perspective of both patients and physicians. This has led to the suggestion that a third party, such as a research nurse or data manager, should be responsible for obtaining informed consent. The objective of this study was to explore the views of data managers concerning the nature, challenges, and rewards of their role and the similarities and differences between their role and that of physicians in obtaining informed consent. Four focus groups in three large teaching hospitals were conducted. Twenty-one data managers who were involved in cancer or pain clinical trials participated. The focus groups were audiotaped, transcribed, and subjected to content analysis to identify themes. Data managers identified three primary roles complementary to that of physicians: information provision, quality assurance of the informed consent process, and ongoing support during the trial. Despite expressed concern that medical and drug company interests may lead to subtle coercion of the patient, participants did not support the notion that they may be solely responsible for the consent process. Participants described a range of ethical dilemmas they confronted, including patients asking them for medical details they could not provide and situations in which they felt that informed consent was compromised in some way, for example, dealing with situations in which the patient appeared to be entering the trial for the wrong reasons due to misunderstanding, need, or passivity. Effective functioning of the multidisciplinary team assisted data managers in performing their role. A range of training needs were identified, particularly communication skills training and trial start-up briefing. The issues raised by these data managers have important implications for the successful conduct of

  16. Evaluation of the Behavior of Technova Corporation Rod-Stiffened Stitched Compression Specimens

    Science.gov (United States)

    Jegley, Dawn C.

    2013-01-01

    Under Space Act Agreement 1347 between NASA and Technova Corporation, Technova designed and fabricated two carbon-epoxy crippling specimens and NASA loaded them to failure in axial compression. Each specimen contained a pultruded rod stiffener which was held to the specimen skin with through-the-thickness stitches. One of these specimens was designed to be nominally the same as pultruded rod stitched specimens fabricated by Boeing under previous programs. In the other specimen, the rod was prestressed in a Technova manufacturing process to increase its ability to carrying compressive loading. Experimental results demonstrated that the specimen without prestressing carried approximately the same load as the similar Boeing specimens and that the specimen with prestressing carried significantly more load than the specimen without prestressing.

  17. Tumor containing fragment number influences immunohistochemistry positive rate of HER2 in biopsy specimens of gastric cancer.

    Science.gov (United States)

    Xu, Chen; Liu, Yalan; Ge, Xiaowen; Jiang, Dongxian; Zhang, Ying; Ji, Yuan; Hou, Jun; Huang, Jie; Su, Jieakesu; Zeng, Haiying; Qin, Jing; Hou, Yingyong

    2017-05-26

    HER2 assessment in biopsy specimens of gastric cancer (GC) is challenging because of the intratumoral heterogeneity. False negative results may be get because of limited biopsy material. The aim of this study is to explore how tumor-containing fragment number and biopsy specimen number affect HER2 immunohistochemistry (IHC) positive rate. Eight hundred and ninety biopsy specimens and 459 paired resected specimens were collected. IHC staining of HER2 was performed. HER2 IHC positive (scored 3+) rate was compared based on tumor-containing fragment number, biopsy specimen number, average size and tumor tissue proportion of tumor-containing fragments. The positive predictability of biopsy specimens to resected specimens was analyzed based on tumor fragment number. HER2 IHC positive rates were 2.0, 3.5, 7.0, 13.2, 17.1, and 15.9% when tumor fragment numbers were 1, 2, 3, 4, 5 and 6 respectively. The rate rose with the increase of tumor fragment number (P = 0.004). ROC curve analysis showed that biopsy specimens exhibited positive predictability when tumor fragment number reached 3, but showed better performance when the number was ≥4 (P fragment number reached 4, no statistic differences were reached in either HER2 IHC positive rate or positive predictability with further increase of the number (P > 0.05). HER2 IHC positive rate was not associated with biopsy number (P = 0.127), average size of tumor fragments (P = 0.397), and tumor tissue proportion of tumor fragments (P = 0.825) directly. The number of tumor-containing fragments influences HER2 IHC positive (scored 3+) rate. Greater than or equal to 4 (≥4) tumor fragments give better results in the positive rate as well as positive predictability. We recommend the number of tumor containing fragments be described in the HER2 IHC pathology reports for clinical reference in endoscopic biopsy specimens of GC.

  18. Finding a vein or obtaining consent: a qualitative study of hepatitis C testing in GP methadone clinics.

    Science.gov (United States)

    Perry, Mark; Chew-Graham, Carolyn

    2003-10-01

    Informed consent is a professional norm, but the promotion of testing for infectious disease in organized clinics and the introduction of targets for uptake, such as those for human immunodeficiency virus (HIV) testing in antenatal clinics, might impair truly voluntary consent. Hepatitis C virus (HCV) is highly prevalent among intravenous drug users (IDUs) and the 'offer' of a serological test for HCV antibodies is now seen as a national standard within drug misuse services, including GP methadone clinics. We hoped that GPs' descriptions of the context and offer of HCV testing could provide an exploratory study of consent within primary care clinics. The aim of this study was to understand GPs' ethical practice when negotiating consent to HCV testing with IDUs. A qualitative semi-structured interview study of 20 GPs in Greater Manchester was carried out. GPs reported that they or their attached drug workers commonly tested for HCV, and many stressed the need for good teamwork and building relationships with 'stable' IDUs before testing. GPs' views on the beneficence of testing and their practices in obtaining consent were diverse. GPs' discourse highlighted important management problems: (i) the adequacy of preparation of some IDUs for testing; (ii) 'opportunistic' HCV testing; and (iii) GPs' recognition of denial after testing. While GPs offered little explicit ethical reflection, occasionally they remarked on tendencies to control a patient's decision, and a deviant case analysis demonstrates how poor teamwork can be associated with coercion. GPs' descriptions suggest that an effective informed consent process is the norm for HCV testing within GP methadone clinics. Importantly, a minority of GPs alluded to the directive effect of team protocols or other problems in obtaining valid consent. We offer recommendations for managing testing to ensure voluntary choice.

  19. Estimation of stress distribution in ferromagnetic tensile specimens using low cost eddy current stress measurement system and BP neural network.

    Directory of Open Access Journals (Sweden)

    Jianwei Li

    Full Text Available Estimation of the stress distribution in ferromagnetic components is very important for evaluating the working status of mechanical equipment and implementing preventive maintenance. Eddy current testing technology is a promising method in this field because of its advantages of safety, no need of coupling agent, etc. In order to reduce the cost of eddy current stress measurement system, and obtain the stress distribution in ferromagnetic materials without scanning, a low cost eddy current stress measurement system based on Archimedes spiral planar coil was established, and a method based on BP neural network to obtain the stress distribution using the stress of several discrete test points was proposed. To verify the performance of the developed test system and the validity of the proposed method, experiment was implemented using structural steel (Q235 specimens. Standard curves of sensors at each test point were achieved, the calibrated data were used to establish the BP neural network model for approximating the stress variation on the specimen surface, and the stress distribution curve of the specimen was obtained by interpolating with the established model. The results show that there is a good linear relationship between the change of signal modulus and the stress in most elastic range of the specimen, and the established system can detect the change in stress with a theoretical average sensitivity of -0.4228 mV/MPa. The obtained stress distribution curve is well consonant with the theoretical analysis result. At last, possible causes and improving methods of problems appeared in the results were discussed. This research has important significance for reducing the cost of eddy current stress measurement system, and advancing the engineering application of eddy current stress testing.

  20. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  1. Dual-Energy CT of Rectal Cancer Specimens

    DEFF Research Database (Denmark)

    Al-Najami, Issam; Beets-Tan, Regina G H; Madsen, Gunvor

    2016-01-01

    is represented by a certain effective Z value, which allows for information on its composition. OBJECTIVE: We wanted to standardize a method for dual-energy scanning of rectal specimens to evaluate the sensitivity and specificity of benign versus malignant lymph node differentiation. Histopathological evaluation...... cancer. MAIN OUTCOME MEASURES: We measured accuracy of differentiating benign from malignant lymph nodes by investigating the following: 1) gadolinium, iodine, and water concentrations in lymph nodes; 2) dual-energy ratio; 3) dual-energy index; and 4) effective Z value. RESULTS: Optimal discriminations...... between benign and malignant lymph nodes were obtained using the following cutoff values: 1) effective Z at 7.58 (sensitivity, 100%; specificity, 90%; and accuracy, 93%), 2) dual-energy ratio at 1.0 × 10 (sensitivity, 96%; specificity, 87%; and accuracy, 90%), 3) dual-energy index at 0.03 (sensitivity, 97...

  2. Compatibility study of the different pole figures in one and the same specimen. Comparison between the results obtained by neutron and by X-ray diffraction

    International Nuclear Information System (INIS)

    Pernot, M.; Penelle, R.; Dervin, P.

    1981-01-01

    Development of a calculation to show directly the compatibility of the different pole figures in the same specimen is exposed. A review of the method by serial development is given. Experimental methods are described. The position of the anisotropy axes is determined. Compatibilities resulting from X-ray and from neutron diffraction is analysed [fr

  3. Bacteriology of Urine Specimens Obtained from Men with ...

    African Journals Online (AJOL)

    Benign prostatic hyperplasia (BPH) is a common condition in the aging male ... A reduction in the concentration of zinc‑associated antimicrobial factor and increasing alkalinity .... the prostate‑specific antigen value, was recorded for all patients.

  4. [A transportation vehicle for laparoscopically obtained follicular specimens].

    Science.gov (United States)

    Fliess, F R; Sudik, R

    1984-01-01

    Structure, function and first results with a vehicle for transportation were described. This apparatus allows to store laparoscopic harvested follicular fluids for a while in constant temperature and in air condition with 5% CO2 in compressed air. Simultaneously the follicular fluids were transported in this vehicle from operating theatre to the laboratory.

  5. Thermal expansion of epoxy-fiberglass composite specimens

    International Nuclear Information System (INIS)

    McElroy, D.L.; Weaver, F.J.; Bridgman, C.

    1986-01-01

    The thermal expansion behavior of three epoxy-fiberglass composite specimens was measured from 20 to 120 0 C (70 to 250 0 F) using a fused quartz push-rod dilatometer. Billets produced by vacuum impregnating layers of two types of fiberglass cloth with an epoxy resin were core-drilled to produce cylindrical specimens. These were used to study expansion perpendicular and parallel to the fiberglass layers. The dilatometer is held at a preselected temperature until steady-state is indicated by stable length and temperature data. Before testing the composite specimens, a reliability check of the dilatometer was performed using a copper secondary standard. This indicated thermal expansion coefficient (α) values within +-2% of expected values from 20 to 200 0 C

  6. Effect of CT Specimen Thickness on the Mechanical Characteristics at the Crack Tip of Stress Corrosion Cracking in Ni-based Alloys

    Science.gov (United States)

    Yinghao, Cui; He, Xue; Lingyan, Zhao

    2017-12-01

    It’s important to obtain accurate stress corrosion crack(SCC) growth rate for quantitative life prediction of components in nuclear power plants. However, the engineering practice shows that the crack tip constraint effect has a great influence on the mechanical properties and crack growth rate of SCC at crack tip. To study the influence of the specimen thickness on the crack tip mechanical properties of SCC, the stress, strain and C integral at creep crack tip are analyzed under different specimens thickness. Results show that the cracked specimen is less likely to crack due to effect of crack tip constraint. When the thickness ratio B/W is larger than 0.1, the crack tip constraint is almost ineffective. Value of C integral is the largest when B/W is 0.25. Then specimen thickness has little effect on the value of C integral. The effect of specimen thickness on the value of C integral is less significant at higher thickness ratio.

  7. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  8. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  9. Effect of ultraviolet light on creatinine measurement in jaundiced specimens

    International Nuclear Information System (INIS)

    Nisbet, J.A.; D'Souza, R.

    1986-01-01

    During initial evaluation of a creatinine method using the RA-1000 analyser, experiments with addition of bilirubin indicated negligible interference. However the finding of a 'zero' creatinine value in an extremely jaundiced specimen prompted to re-examine the method. In contrast to earlier findings with normal plasma containing added bilirubin, the authors found that plasma from moderately or severely jaundiced patients gave creatinine values lower than those obtained with a reference method. Since bilirubin has been implicated in the interference, the authors studied the effect of destroying bilirubin with ultraviolet light to see if this provided a practical solution to the problem. (Auth.)

  10. Structure and morphology of dispersed lanthanum powders and compact specimens of them

    International Nuclear Information System (INIS)

    Strashinskaya, L.V.; Dudnik, E.M.; Kopylova, L.I.; Savvakin, G.I.

    1986-01-01

    In this work a comparative electron microscopic investigation was made of the structure of dispersed LaB 6 powders. Specimens were prepared from the original and shock-wavetreated LaB 6 powders by hot-pressing. The compaction was done in such a manner that the coarser grains are surrounded by finer grains and all of the grains are rounded. Dispersion of LaB 6 powder by a shock wave leads to a decrease in the residual porosity of hot pressed specimens as the result of an increase in the quantity of finer fraction (1-2 um) in the mixture, i.e., better compaction, and the coarser grains are as immersed in a dense ''matrix'' of the finer ones. To obtain compact porosity-free parts of ultradispersed powders it is necessary to have a purer original material and to adopt special methods of forming which would make it possible to realize the potential reserves of activity of these powders in sintering. Illustrations and table are shown

  11. Accurate characterization of wafer bond toughness with the double cantilever specimen

    Science.gov (United States)

    Turner, Kevin T.; Spearing, S. Mark

    2008-01-01

    The displacement loaded double cantilever test, also referred to as the "Maszara test" and the "crack opening method" by the wafer bonding community, is a common technique used to evaluate the interface toughness or surface energy of direct wafer bonds. While the specimen is widely used, there has been a persistent question as to the accuracy of the method since the actual specimen geometry differs from the ideal beam geometry assumed in the expression used for data reduction. The effect of conducting the test on whole wafer pairs, in which the arms of cantilevers are wide plates rather than slender beams, is examined in this work using finite element analysis. A model is developed to predict the equilibrium shape of the crack front and to develop a corrected expression for calculating interface toughness from crack length measurements obtained in tests conducted on whole wafer pairs. The finite element model, which is validated through comparison to experiments, demonstrates that using the traditional beam theory-based expressions for data reduction can lead to errors of up to 25%.

  12. Rehydration of forensically important larval Diptera specimens.

    Science.gov (United States)

    Sanford, Michelle R; Pechal, Jennifer L; Tomberlin, Jeffery K

    2011-01-01

    Established procedures for collecting and preserving evidence are essential for all forensic disciplines to be accepted in court and by the forensic community at large. Entomological evidence, such as Diptera larvae, are primarily preserved in ethanol, which can evaporate over time, resulting in the dehydration of specimens. In this study, methods used for rehydrating specimens were compared. The changes in larval specimens with respect to larval length and weight for three forensically important blow fly (Diptera: Calliphoridae) species in North America were quantified. Phormia regina (Meigen), Cochliomyia macellaria (F.), and Chrysomya rufifacies (Macquart) third-instar larvae were collected from various decomposing animals and preserved with three preservation methods (80% ethanol, 70% isopropyl alcohol, and hot-water kill then 80% ethanol). Preservative solutions were allowed to evaporate. Rehydration was attempted with either of the following: 80% ethanol, commercial trisodium phosphate substitute solution, or 0.5% trisodium phosphate solution. All three methods partially restored weight and length of specimens recorded before preservation. Analysis of variance results indicated that effects of preservation, rehydration treatment, and collection animal were different in each species. The interaction between preservative method and rehydration treatment had a significant effect on both P. regina and C. macellaria larval length and weight. In addition, there was a significant interaction effect of collection animal on larval C. macellaria measurements. No significant effect was observed in C. rufifacies larval length or weight among the preservatives or treatments. These methods could be used to establish a standard operating procedure for dealing with dehydrated larval specimens in forensic investigations.

  13. Illicit drugs in alternative biological specimens: a case report.

    Science.gov (United States)

    Margalho, Cláudia; Franco, João; Corte-Real, Francisco; Vieira, Duarte Nuno

    2011-04-01

    Postmortem tissues (e.g. liver, kidney) have been long used in forensic applications especially in those cases where blood is unavailable. The aim of this paper is to demonstrate the importance of the information provided to the forensic toxicologist at the time of carrying out the toxicological analysis, especially in cases where the samples commonly used in forensic toxicology are unavailable. This work describes the toxicological findings in a violent death resulting from a man who was hit by a train. Vitreous humor, liver and kidney were sent for toxicological analysis, once it was not possible to obtain blood and urine. The validated procedures used in the routine casework of Forensic Toxicology Laboratory of the Centre Branch of the National Institute of Legal Medicine, were applied in the analysis of liver, kidney and vitreous humor, using gas chromatography-mass spectrometry after solid-phase extraction and gas chromatography-flame ionization detector for the analysis of drugs of abuse and ethanol, respectively. Morphine, codeine, cocaine, benzoylecgonine and ecgonine methyl ester were found in the liver and in the kidney and no ethanol was found in the vitreous humor. The method validation included the study of specificity, selectivity, limits of detection, recovery and carryover. Although blood and urine are the most common and preferred matrices used for toxicological studies involving drugs of abuse, sometimes the choice of specimen is determined by the case under investigation. The forensic pathologist must be aware that relevant information must be provided so that the toxicological analysis can be conducted in accordance with case history, particularly when the only samples available for analysis are these "unconventional" specimens, since the interpretation of the obtained results is more difficult. Copyright © 2011 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  14. Demonstration of Laser Cutting System for Tube Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  15. Rapid Fractionation and Isolation of Whole Blood Components in Samples Obtained from a Community-based Setting.

    Science.gov (United States)

    Weckle, Amy; Aiello, Allison E; Uddin, Monica; Galea, Sandro; Coulborn, Rebecca M; Soliven, Richelo; Meier, Helen; Wildman, Derek E

    2015-11-30

    Collection and processing of whole blood samples in a non-clinical setting offers a unique opportunity to evaluate community-dwelling individuals both with and without preexisting conditions. Rapid processing of these samples is essential to avoid degradation of key cellular components. Included here are methods for simultaneous peripheral blood mononuclear cell (PBMC), DNA, RNA and serum isolation from a single blood draw performed in the homes of consenting participants across a metropolitan area, with processing initiated within 2 hr of collection. We have used these techniques to process over 1,600 blood specimens yielding consistent, high quality material, which has subsequently been used in successful DNA methylation, genotyping, gene expression and flow cytometry analyses. Some of the methods employed are standard; however, when combined in the described manner, they enable efficient processing of samples from participants of population- and/or community-based studies who would not normally be evaluated in a clinical setting. Therefore, this protocol has the potential to obtain samples (and subsequently data) that are more representative of the general population.

  16. Instrumentation of a Charpy-pendulum. Additional data obtained from it and its application to nuclear reactor pressure vessels surveillance programs

    International Nuclear Information System (INIS)

    Chomik, Enrique P.; Dhers, Horacio; Iorio, Antonio F.; Ciriani, Dario F.

    1999-01-01

    Charpy test gives information about a material dynamic fracture behavior. In a plain Charpy test, this information is the absorbed energy during fracture of the specimen, lateral deformation and the percentage of ductile fracture of the specimen. These parameters can then be used for the determination of the material response to a dynamic applied load, and are used at present to determine the brittle-ductile transition temperature of a material. However, there is a lot of additional information that can be obtained from a Charpy test, which is vital for the case of surveillance programs of nuclear power plants, where it is necessary to get the most available information from the specimens to be tested, because each one of them was irradiated for many years under temperature and neutronic flux conditions similar to that of the internal surface of the reactor pressure vessel, which converts these specimens in unique and very expensive ones. This additional information can be obtained from the curve that determines the evolution of the applied force to the specimen throughout the time involved in its fracture. It was possible to instrument a Charpy pendulum at a fraction of the cost necessary to buy an instrumentation package like the ones available in the market, and since the instrumentation equipment obtained is easy to transport. It has the additional advantage that can be used to instrument any other pendulum replacing only the hammer of the pendulum with a instrumented one for that pendulum. (author)

  17. Irradiation of UO2 specimens with molten cores in a pressurized water loop. Test X-2-x

    International Nuclear Information System (INIS)

    Bain, A.S.

    1961-08-01

    Two Zircaloy-2 clad specimens containing stoichiometric UO 2 pellets were irradiated in a pressurized water loop for 379 hours at heat ratings sufficient to cause central melting of the UO 2 . There was no appearance of localized overheating or accelerated corrosion of the sheath, but the diametral increases were considerably larger than those observed in loop specimens irradiated at lower heat ratings. The length increases, however, were approximately the same as those measured for specimens at lower ratings. There was a clearly visible demarcation between UO 2 that had been molten and that which had not. The value of ∫ 500 o C Tm kdθ = 74 ± W/cm was essentially the same as that obtained from the short-duration tests in the Hydraulic Rabbit, indicating there is no marked decrease in thermal conductivity of the UO 2 fuel in irradiations up to 379 hours. (author)

  18. Phylogeny of the Clinically Relevant Species of the Emerging Fungus Trichoderma and Their Antifungal Susceptibilities

    Science.gov (United States)

    Sandoval-Denis, Marcelo; Sutton, Deanna A.; Cano-Lira, José F.; Fothergill, Annette W.; Wiederhold, Nathan P.; Guarro, Josep

    2014-01-01

    A set of 73 isolates of the emerging fungus Trichoderma isolated from human and animal clinical specimens were characterized morphologically and molecularly using a multilocus sequence analysis that included the internal transcribed spacer (ITS) regions of the nuclear ribosomal DNA and fragments of the translation elongation factor 1 alpha (Tef1), endochitinase CHI18-5 (Chi18-5), and actin 1 (Act1) genes. The most frequent species was Trichoderma longibrachiatum (26%), followed by Trichoderma citrinoviride (18%), the Hypocrea lixii/Trichoderma harzianum species complex (15%), the newly described species Trichoderma bissettii (12%), and Trichoderma orientale (11%). The most common anatomical sites of isolation in human clinical specimens were the respiratory tract (40%), followed by deep tissue (30%) and superficial tissues (26%), while all the animal-associated isolates were obtained from superficial tissue samples. Susceptibilities of the isolates to eight antifungal drugs in vitro showed mostly high MICs, except for voriconazole and the echinocandins. PMID:24719448

  19. Eddy current crack detection capability assessment approach using crack specimens with differing electrical conductivity

    Science.gov (United States)

    Koshti, Ajay M.

    2018-03-01

    Like other NDE methods, eddy current surface crack detectability is determined using probability of detection (POD) demonstration. The POD demonstration involves eddy current testing of surface crack specimens with known crack sizes. Reliably detectable flaw size, denoted by, a90/95 is determined by statistical analysis of POD test data. The surface crack specimens shall be made from a similar material with electrical conductivity close to the part conductivity. A calibration standard with electro-discharged machined (EDM) notches is typically used in eddy current testing for surface crack detection. The calibration standard conductivity shall be within +/- 15% of the part conductivity. This condition is also applicable to the POD demonstration crack set. Here, a case is considered, where conductivity of the crack specimens available for POD testing differs by more than 15% from that of the part to be inspected. Therefore, a direct POD demonstration of reliably detectable flaw size is not applicable. Additional testing is necessary to use the demonstrated POD test data. An approach to estimate the reliably detectable flaw size in eddy current testing for part made from material A using POD crack specimens made from material B with different conductivity is provided. The approach uses additional test data obtained on EDM notch specimens made from materials A and B. EDM notch test data from the two materials is used to create a transfer function between the demonstrated a90/95 size on crack specimens made of material B and the estimated a90/95 size for part made of material A. Two methods are given. For method A, a90/95 crack size for material B is given and POD data is available. Objective of method A is to determine a90/95 crack size for material A using the same relative decision threshold that was used for material B. For method B, target crack size a90/95 for material A is known. Objective is to determine decision threshold for inspecting material A.

  20. Laboratory specimens and genetic privacy: evolution of legal theory.

    Science.gov (United States)

    Lewis, Michelle Huckaby

    2013-03-01

    Although laboratory specimens are an important resource for biomedical research, controversy has arisen when research has been conducted without the knowledge or consent of the individuals who were the source of the specimens. This paper summarizes the most important litigation regarding the research use of laboratory specimens and traces the evolution of legal theory from property claims to claims related to genetic privacy interests. © 2013 American Society of Law, Medicine & Ethics, Inc.

  1. 50 CFR 31.11 - Donation and loan of wildlife specimens.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Donation and loan of wildlife specimens... of Wildlife Reduction and Disposal § 31.11 Donation and loan of wildlife specimens. Wildlife specimens may be donated or loaned to public institutions for specific purposes. Donation or loans of...

  2. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  3. Drone Transport of Microbes in Blood and Sputum Laboratory Specimens.

    Science.gov (United States)

    Amukele, Timothy K; Street, Jeff; Carroll, Karen; Miller, Heather; Zhang, Sean X

    2016-10-01

    Unmanned aerial vehicles (UAVs) could potentially be used to transport microbiological specimens. To examine the impact of UAVs on microbiological specimens, blood and sputum culture specimens were seeded with usual pathogens and flown in a UAV for 30 ± 2 min. Times to recovery, colony counts, morphologies, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based identifications of the flown and stationary specimens were similar for all microbes studied. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Application of the standard options of the FITNET procedure to the structural integrity assessment of welded specimens containing cracks

    International Nuclear Information System (INIS)

    Dzioba, Ihor; Neimitz, Andrzej

    2007-01-01

    In this paper, the structural integrity of welded specimens is assessed. The specimens were welded using a conventional technique, MAG, and an unconventional one, laser technology. Welded specimens were of the central crack under tension (CCT) type. The elements were loaded, the maximum load was recorded, and the second and the third options of the FITNET procedure were utilized to estimate the critical loading. Estimated and recorded loads were compared to verify the conservatism of the estimated results. For comparison, the results obtained using Option 1 of the FITNET procedure (not recommended in the case analysed) are also presented. Results of the mechanical properties, hardness, fracture toughness for the base and the weld material and residual stress distributions are reported for both MAG and laser welding techniques. The results obtained confirm that the FITNET procedures were properly deigned. The higher the level of analysis, the smaller the conservatism of predictions observed. The overconservative conclusions, following from the lower level of analysis, suggest that the structural element is endangered, do not have to exclude it from exploitation. The higher level of analysis can, in some cases, confirm that the structural element containing a crack can still be exploited

  5. High resolution SAW elastography for ex-vivo porcine skin specimen

    Science.gov (United States)

    Zhou, Kanheng; Feng, Kairui; Wang, Mingkai; Jamera, Tanatswa; Li, Chunhui; Huang, Zhihong

    2018-02-01

    Surface acoustic wave (SAW) elastography has been proven to be a non-invasive, non-destructive method for accurately characterizing tissue elastic properties. Current SAW elastography technique tracks generated surface acoustic wave impulse point by point which are a few millimeters away. Thus, reconstructed elastography has low lateral resolution. To improve the lateral resolution of current SAW elastography, a new method was proposed in this research. A M-B scan mode, high spatial resolution phase sensitive optical coherence tomography (PhS-OCT) system was employed to track the ultrasonically induced SAW impulse. Ex-vivo porcine skin specimen was tested using this proposed method. A 2D fast Fourier transform based algorithm was applied to process the acquired data for estimating the surface acoustic wave dispersion curve and its corresponding penetration depth. Then, the ex-vivo porcine skin elastogram was established by relating the surface acoustic wave dispersion curve and its corresponding penetration depth. The result from the proposed method shows higher lateral resolution than that from current SAW elastography technique, and the approximated skin elastogram could also distinguish the different layers in the skin specimen, i.e. epidermis, dermis and fat layer. This proposed SAW elastography technique may have a large potential to be widely applied in clinical use for skin disease diagnosis and treatment monitoring.

  6. Consistency of direct microscopic examination and ELISA in detection of Giardia in stool specimen among children

    Directory of Open Access Journals (Sweden)

    Zohreh Torabi

    2014-09-01

    Full Text Available Objective: To investigate the consistency of direct microscopic examination and ELISA for determination of Giadia in stool specimen. Method: Study population consisted of children with any clinical symptoms of Giardia infestation since last two weeks. Fresh stool specimen was collected from each child. The stools specimens were assessed by two methods of direct microscopic examination and ELISA.The degree of agreement between direct stool exam and ELISA was calculated by Cohen's kappa coefficient. Results: In this study, 124 children with age range 2-12 years were investigated. A total of 64 (61.7% and 79 (65.7% of children had Giardia by direct stool exam and ELISA test respectively. There was association between frequency of constipation and Giardia infection (P=0.036. The Cohen's kappa coefficient calculated for degree of agreement between direct stool exam and ELISA showed κ=0.756 (P<0.001. Conclusions: The frequency of Giardia infection in symptomatic children was high and there was high agreement rate between ELISA and direct stool smear.

  7. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  8. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  9. High-Resolution Ultrasonography (US) of Appendiceal Specimens: Differentiation of Acute Non-perforated Appendicitis from Perforated Appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyo Chang; Kim, Suk; Im, Han Hyeok; Lee, Sang Jin; Yang, Seung Boo; Lee, Seung Woo; Kim, Il Young [Soonchunhyang University Gumi Hospital, Gumi (Korea, Republic of); Lee, Hae Kyung [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Kwon, Kui Hyang; Shin, Hyung Chul [Soonchunhyang University, College of Medicine, Seoul (Korea, Republic of)

    2007-09-15

    To analyze surgical specimens from patients with acute non-perforated and perforated appendicitis using high-resolution ultrasonography (US), and to correlate the US features with the pathologic findings. One hundred and six surgical appendix specimens obtained from patients with suspected acute appendicitis were evaluated. The following US features were evaluated for differentiating acute non-perforated appendicitis from perforated appendicitis: circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, the sum of opposing walls {>=} 9 mm and the presence of appendicoliths. The sensitivity and specificity of the US findings for diagnosing perforated appendicitis were determined. All US features were detected significantly more often in the perforated appendicitis group of specimens. The disruption of the serosal layer was the most significant independent predictor of perforation (p < .001). The sensitivity for circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, wall thickness {>=} 9 mm, and the presence of appendicoliths individually was 84.6%, 69.2%, 61.5%, 73.1% and 46.2%, respectively. The specificity for all of these findings was 86.3%, 98.7%, 95.0%, 85.0% and 85.0%, respectively. High-resolution US of appendiceal specimens was very useful for differentiating acute non-perforated from perforated appendicitis

  10. An indirect haemagglutination test for demonstration of gonococcal antibodies using gonococcal pili as antigen. II. Serological investigation of patients attending a dermato-venereological outpatients clinic in Copenhagen

    DEFF Research Database (Denmark)

    Reimann, K; Lind, I; Andersen, Klaus Ejner

    1980-01-01

    A total of 1223 serum specimens were obtained from 649 consecutive patients attending a dermatovenereological out-patient clinic in Copenhagen with a request for venereal disease control. The sera were examined for gonococcal antibodies by both a gonococcal complement fixation test (GCF) and an i...

  11. Gram staining of protected pulmonary specimens in the early diagnosis of ventilator-associated pneumonia.

    Science.gov (United States)

    Mimoz, O; Karim, A; Mazoit, J X; Edouard, A; Leprince, S; Nordmann, P

    2000-11-01

    We evaluated prospectively the use of Gram staining of protected pulmonary specimens to allow the early diagnosis of ventilator-associated pneumonia (VAP), compared with the use of 60 bronchoscopic protected specimen brushes (PSB) and 126 blinded plugged telescopic catheters (PTC) obtained from 134 patients. Gram stains were from Cytospin slides; they were studied for the presence of microorganisms in 10 and 50 fields by two independent observers and classified according to their Gram stain morphology. Quantitative cultures were performed after serial dilution and plating on appropriate culture medium. A final diagnosis of VAP, based on a culture of > or = 10(3) c.f.u. ml-1, was established after 81 (44%) samplings. When 10 fields were analysed, a strong relationship was found between the presence of bacteria on Gram staining and the final diagnosis of VAP (for PSB and PTC respectively: sensitivity 74 and 81%, specificity 94 and 100%, positive predictive value 91 and 100%, negative predictive value 82 and 88%). The correlation was less when we compared the morphology of microorganisms observed on Gram staining with those of bacteria obtained from quantitative cultures (for PSB and PTC respectively: sensitivity 54 and 69%, specificity 86 and 89%, positive predictive value 72 and 78%, negative predictive value 74 and 84%). Increasing the number of fields read to 50 was associated with a slight decrease in specificity and positive predictive value of Gram staining, but with a small increase in its sensitivity and negative predictive value. The results obtained by the two observers were similar to each other for both numbers of fields analysed. Gram staining of protected pulmonary specimens performed on 10 fields predicted the presence of VAP and partially identified (using Gram stain morphology) the microorganisms growing at significant concentrations, and could help in the early choice of the treatment of VAP. Increasing the number of fields read or having the Gram

  12. Determination of J-integral R-curves for the pressure vessel material A 533 B1 using the potential drop technique and the multi-specimen method

    International Nuclear Information System (INIS)

    Krompholz, K.; Ullrich, G.

    1985-01-01

    J-integral experiments at room temperature were performed on three point bend type specimens of the nuclear pressure vessel material A 533 B1 with a/w-ratios of 0.3 and 0.5. Following the ASTM-proposal for the multi-specimen technique a value is obtained close to the value obtained in the HSST round robin test. On the other hand, from the measurement of the Jsub(IC)-value by means of the potential drop technique there is an indication that a lower value of Jsub(IC) is correct. This is in agreement with the multi-specimen technique using linear regression lines without excluding 'invalid' points. That is reasonable if fractographic investigations gives clear indications that stable crack growth has occurred as is the case in this work. (Auth.)

  13. Clinical management of rapidly growing mycobacterial cutaneous infections in patients after mesotherapy.

    Science.gov (United States)

    Regnier, Stéphanie; Cambau, Emmanuelle; Meningaud, Jean-Paul; Guihot, Amelie; Deforges, Lionel; Carbonne, Anne; Bricaire, François; Caumes, Eric

    2009-11-01

    Increasing numbers of patients are expressing an interest in mesotherapy as a method of reducing body fat. Cutaneous infections due to rapidly growing mycobacteria are a common complication of such procedures. We followed up patients who had developed cutaneous infections after undergoing mesotherapy during the period October 2006-January 2007. Sixteen patients were infected after mesotherapy injections performed by the same physician. All patients presented with painful, erythematous, draining subcutaneous nodules at the injection sites. All patients were treated with surgical drainage. Microbiological examination was performed on specimens that were obtained before and during the surgical procedure. Direct examination of skin smears demonstrated acid-fast bacilli in 25% of the specimens that were obtained before the procedure and 37% of the specimens obtained during the procedure; culture results were positive in 75% of the patients. Mycobacterium chelonae was identified in 11 patients, and Mycobacterium frederiksbergense was identified in 2 patients. Fourteen patients were treated with antibiotics, 6 received triple therapy as first-line treatment (tigecycline, tobramycin, and clarithromycin), and 8 received dual therapy (clarithromycin and ciprofloxacin). The mean duration of treatment was 14 weeks (range, 1-24 weeks). All of the patients except 1 were fully recovered 2 years after the onset of infection, with the mean time to healing estimated at 6.2 months (range, 1-15 months). This series of rapidly growing mycobacterial cutaneous infections highlights the difficulties in treating such infections and suggests that in vitro susceptibility to antibiotics does not accurately predict their clinical efficacy.

  14. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  15. Using Anisotropic 3D Minkowski Functionals for Trabecular Bone Characterization and Biomechanical Strength Prediction in Proximal Femur Specimens

    Science.gov (United States)

    Nagarajan, Mahesh B.; De, Titas; Lochmüller, Eva-Maria; Eckstein, Felix; Wismüller, Axel

    2017-01-01

    The ability of Anisotropic Minkowski Functionals (AMFs) to capture local anisotropy while evaluating topological properties of the underlying gray-level structures has been previously demonstrated. We evaluate the ability of this approach to characterize local structure properties of trabecular bone micro-architecture in ex vivo proximal femur specimens, as visualized on multi-detector CT, for purposes of biomechanical bone strength prediction. To this end, volumetric AMFs were computed locally for each voxel of volumes of interest (VOI) extracted from the femoral head of 146 specimens. The local anisotropy captured by such AMFs was quantified using a fractional anisotropy measure; the magnitude and direction of anisotropy at every pixel was stored in histograms that served as a feature vectors that characterized the VOIs. A linear multi-regression analysis algorithm was used to predict the failure load (FL) from the feature sets; the predicted FL was compared to the true FL determined through biomechanical testing. The prediction performance was measured by the root mean square error (RMSE) for each feature set. The best prediction performance was obtained from the fractional anisotropy histogram of AMF Euler Characteristic (RMSE = 1.01 ± 0.13), which was significantly better than MDCT-derived mean BMD (RMSE = 1.12 ± 0.16, p<0.05). We conclude that such anisotropic Minkowski Functionals can capture valuable information regarding regional trabecular bone quality and contribute to improved bone strength prediction, which is important for improving the clinical assessment of osteoporotic fracture risk. PMID:29170581

  16. Comparison of immersion density and improved microstructural characterization methods for measuring swelling in small irradiated disk specimens

    International Nuclear Information System (INIS)

    Sawai, T.; Suzuki, M.; Hishinuma, A.; Maziasz, P.J.

    1992-01-01

    The procedure of obtaining microstructural data from reactor-irradiated specimens has been carefully checked for accuracy by comparison of swelling data obtained from transmission electron microscopy (TEM) observations of cavities with density-change data measured using the Precision Densitometer at Oak Ridge National Laboratory (ORNL). Comparison of data measured by both methods on duplicate or, in some cases, on the same specimen has shown some appreciable discrepancies for US/Japan collaborative experiments irradiated in the High Flux Isotope Reactor (HFIR). The contamination spot separation (CSS) method was used in the past to determine the thickness of a TEM foil. Recent work has revealed an appreciable error in this method that can result in an overestimation of the foil thickness. This error causes lower swelling values to be measured by TEM microstructural observation relative to the Precision Densitometer. An improved method is proposed for determining the foil thickness by the CSS method, which includes a correction for the systematic overestimation of foil thickness. (orig.)

  17. Geographic distribution and clinical description of leishmaniasis cases in Peru.

    Science.gov (United States)

    Lucas, C M; Franke, E D; Cachay, M I; Tejada, A; Cruz, M E; Kreutzer, R D; Barker, D C; McCann, S H; Watts, D M

    1998-08-01

    Studies were conducted from 1986 through 1993 to further define the geographic distribution and relative importance of different species of Leishmania as a cause of leishmaniasis in Peru. Patients with a clinical diagnosis of cutaneous and/or mucosal or diffuse cutaneous leishmaniasis were enrolled at the Naval Medical Research Institute Detachment (NAMRID) Laboratory in Lima, the Tropical Disease Clinic at San Marcos University Daniel A. Carrión, the Central Military Hospital, and a Ministry of Health hospital in Cusco, Peru. Clinical features, lesion aspirates, and biopsy tissue were obtained from each patient. All specimens were collected and assayed separately, including multiple specimens from some of the same patients for Leishmania parasites by inoculating aliquots of either aspirates or biopsy tissue suspensions onto Senekji's blood agar medium. Stocks of Leishmania isolates were used to prepare promastigotes to produce extracts for identifying the Leishmania species by the cellulose acetate electrophoresis enzyme technique. A total of 351 isolates of Leishmania were obtained from 350 patients who were infected primarily in the low and high jungle of at least 15 different Departments of Peru. Of the 351 isolates, 79% were identified as L. (V.) braziliensis, 7% as L. (V.) guyanensis, 10% as L. (V.) peruviana, 2% as L. (V.) lainsoni, and 1.7% as L. (L.) amazonensis. The clinical form of disease varied depending on the species of Leishmania, with L. (V.) braziliensis being associated most frequently with cutaneous, mucosal ulcers and mixed cutaneous and mucosal disease, and L. (V) peruviana, L. (V.) guyanensis, L. (V.) lainsoni with cutaneous lesions. Leishmania (L.) amazonensis was isolated from six patients, three with cutaneous lesions, one with mucosal lesions, and two with diffuse cutaneous lesions. Among all of the leishmaniasis cases, males were affected more frequently, and cases occurred among patients less than 10 to more than 51 years of age. These

  18. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  19. Possibility of obtaining reliable information on component safety by means of large-scale tensile samples with Orowan-Soete flaws

    International Nuclear Information System (INIS)

    Aurich, D.; Wobst, K.; Kafka, H.

    1984-01-01

    The aim of the paper is to review the present knowledge regarding the ability of wide plate tensile specimen with saw cut trough center flaws of providing accurate information on component reliability; it points out the advantages and disadvantages of this specimen geometries. The effect of temperature, specimen geometry, ligament size and notch radii are discussed in comparison with other specimen geometries. This is followed by a comparison of the results of such tests with tests on inside stressed tanks. Conclusions: wide-plate tensile specimen are generally appropriate for assessing welded joints. However, they result in a more favourable evaluation of low-toughness steels from the point of view of crack growth than of high-toughness and soft steels in case of stresses with incipient cracks, as compared with the results obtained with three-point bending samples. (orig.) [de

  20. Fracture mechanics characterisation of medium-size adhesive joint specimens

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  1. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  2. Old Plants, New Tricks: Phenological Research Using Herbarium Specimens.

    Science.gov (United States)

    Willis, Charles G; Ellwood, Elizabeth R; Primack, Richard B; Davis, Charles C; Pearson, Katelin D; Gallinat, Amanda S; Yost, Jenn M; Nelson, Gil; Mazer, Susan J; Rossington, Natalie L; Sparks, Tim H; Soltis, Pamela S

    2017-07-01

    The timing of phenological events, such as leaf-out and flowering, strongly influence plant success and their study is vital to understanding how plants will respond to climate change. Phenological research, however, is often limited by the temporal, geographic, or phylogenetic scope of available data. Hundreds of millions of plant specimens in herbaria worldwide offer a potential solution to this problem, especially as digitization efforts drastically improve access to collections. Herbarium specimens represent snapshots of phenological events and have been reliably used to characterize phenological responses to climate. We review the current state of herbarium-based phenological research, identify potential biases and limitations in the collection, digitization, and interpretation of specimen data, and discuss future opportunities for phenological investigations using herbarium specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Multiaxial Cycle Deformation and Low-Cycle Fatigue Behavior of Mild Carbon Steel and Related Welded-Metal Specimen

    Directory of Open Access Journals (Sweden)

    Weilian Qu

    2017-01-01

    Full Text Available The low-cycle fatigue experiments of mild carbon Q235B steel and its related welded-metal specimens are performed under uniaxial, in-phase, and 90° out-of-phase loading conditions. Significant additional cyclic hardening for 90° out-of-phase loading conditions is observed for both base metal and its related weldment. Besides, welding process produces extra additional hardening under the same loading conditions compared with the base metal. Multiaxial low-cycle fatigue strength under 90° out-of-phase loading conditions is significantly reduced for both base-metal and welded-metal specimens. The weldment has lower fatigue life than the base metal under the given loading conditions, and the fatigue life reduction of weldment increases with the increasing strain amplitude. The KBM, FS, and MKBM critical plane parameters are evaluated for the fatigue data obtained. The FS and MKBM parameters are found to show better correlation with fatigue lives for both base-metal and welded-metal specimens.

  4. Design of four-point SENB specimens with stable crack growth

    DEFF Research Database (Denmark)

    Jørgensen, Jeppe Bjørn; Kildegaard, Casper; Sørensen, Bent F.

    2018-01-01

    A four-point single-edge-notch-beam (SENB) test specimen loaded in displacement control (fixed grip) is proposed for studying crack deflection at bi-material interfaces. In order to ensure stable crack growth, a novel analytical model of the four-point SENB specimen in fixed grip is derived...... and compared with numerical models. Model results show that the specimen should be short and thick, and the start-crack length should be deep for the crack to propagate stable towards the bi-material interface. Observations from experimental tests of four-point SENB specimens with different start-crack lengths...

  5. An improved method for obtaining small pressed powder pellets for the analysis by XRF

    International Nuclear Information System (INIS)

    D'Angelo, J.; Marchevsky, E.; Strasser, E.; Perino, E.

    2002-01-01

    A rapid, very low cost of instrumentation and simple approach to specimen preparation for the analysis by X-ray fluorescence spectrometry is presented. This technique requires a few mg of powders samples, Which are compressed to produce pellets. This procedure is employed for determining major and trace elements in muscovites and K-feldspars. Factors affecting measured intensities, such as particle size and distribution, surface texture, pelletizing pressure, etc, are considered. A description of new sample preparation device, including technical characteristics, is also given. It is demonstrated that suitable specimen presentation to the X-ray beam is obtained by using our procedure. (author)

  6. The preanalytic phase in veterinary clinical pathology.

    Science.gov (United States)

    Braun, Jean-Pierre; Bourgès-Abella, Nathalie; Geffré, Anne; Concordet, Didier; Trumel, Cathy

    2015-03-01

    This article presents the general causes of preanalytic variability with a few examples showing specialists and practitioners that special and improved care should be given to this too often neglected phase. The preanalytic phase of clinical pathology includes all the steps from specimen collection to analysis. It is the phase where most laboratory errors occur in human, and probably also in veterinary clinical pathology. Numerous causes may affect the validity of the results, including technical factors, such as the choice of anticoagulant, the blood vessel sampled, and the duration and conditions of specimen handling. While the latter factors can be defined, influence of biologic and physiologic factors such as feeding and fasting, stress, and biologic and endocrine rhythms can often not be controlled. Nevertheless, as many factors as possible should at least be documented. The importance of the preanalytic phase is often not given the necessary attention, although the validity of the results and consequent clinical decision making and medical management of animal patients would likely be improved if the quality of specimens submitted to the laboratory was optimized. © 2014 American Society for Veterinary Clinical Pathology.

  7. How to open the treasure chest? Optimising DNA extraction from herbarium specimens.

    Science.gov (United States)

    Särkinen, Tiina; Staats, Martijn; Richardson, James E; Cowan, Robyn S; Bakker, Freek T

    2012-01-01

    Herbarium collections are potentially an enormous resource for DNA studies, but the use of herbarium specimens in molecular studies has thus far been slowed down by difficulty in obtaining amplifiable DNA. Here we compare a set of commercially available DNA extraction protocols and their performance in terms of DNA purity and yield, and PCR amplification success as measured by using three differentially sized markers, the rbcL barcoding marker (cpDNA), the LEAFY exon 3 (nrDNA), and the trnL((UAA)) P6 loop (cpDNA). Results reveal large differences between extraction methods, where DNA purity rather than yield is shown to be strongly correlated with PCR success. Amplicon size shows similarly strong correlation with PCR success, with the shortest fragment showing the highest success rate (78%, P6 loop, 10-143 base pairs (bp)) and the largest fragment the lowest success (10%, rbcL, 670 bp). The effect of specimen preparation method on PCR success was also tested. Results show that drying method strongly affects PCR success, especially the availability of fragments longer than 250 bp, where longer fragments are more available for PCR amplification in air dried material compared to alcohol dried specimens. Results from our study indicate that projects relying on poor-quality starting material such as herbarium or scat samples should focus on extracting pure DNA and aim to amplify short target regions (herbarium samples available into barcoding initiatives and other molecular studies.

  8. Experimental and numerical investigation of the mixed-mode delamination in Arcan laminated specimens

    International Nuclear Information System (INIS)

    Choupani, Naghdali

    2008-01-01

    This paper investigates mixed-mode interlaminar fracture behaviour in woven carbon fibre/polyetherimide (CF/PEI) thermoplastic composite material based on experimental and numerical analyses. Experiments were conducted on modified Arcan specimens using the special test loading device. By varying the loading angle from 0 o to 90 o , pure mode-I, pure mode-II and a wide range of mixed-mode data were obtained experimentally. Using the finite-element results, correction factors were applied to the CF/PEI fracture specimen. By employing experimentally measured critical loads and the aid of the finite-element method, mixed-mode interlaminar fracture toughness for the composite under consideration determined. The failure response of CF/PEI composite was compared to the different mixed-mode failure criteria, and the best criterion was selected. The fracture surfaces of the CF/PEI composite under different mixed-mode loading conditions were examined by optical and scanning electron microscopy to gain insight into the failure responses

  9. Cluster analysis in soft X-ray spectromicroscopy: Finding the patterns in complex specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lerotic, M. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States)]. E-mail: lerotic@xray1.physics.sunysb.edu; Jacobsen, C. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States); Gillow, J.B. [Environmental Sciences Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Francis, A.J. [Environmental Sciences Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Wirick, S. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States); Vogt, S. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Maser, J. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2005-06-15

    Soft X-ray spectromicroscopy provides spectral data on the chemical speciation of light elements at sub-100 nanometer spatial resolution. If all chemical species in a specimen are known and separately characterized, existing approaches can be used to measure the concentration of each component at each pixel. In other situations such as in biology or environmental science, this approach may not be possible. We have previously described [M. Lerotic, C. Jacobsen, T. Schaefer, S. Vogt, Ultramicroscopy 100 (1-2) (2004) 35] the use of principle component analysis (PCA) to orthogonalize and noise-filter spectromicroscopy data, and cluster analysis (Canada) to classify the analyzed data and obtain thickness maps of representative spectra. We describe here an extension of that work employing an angle distance measure; this measure provides better classification based on spectral signatures alone in specimens with significant thickness variations. The method is illustrated using simulated data, and also to examine sporulation in the bacterium Clostridium sp.

  10. Specimen environments in thermal neutron scattering experiments

    International Nuclear Information System (INIS)

    Cebula, D.J.

    1980-11-01

    This report is an attempt to collect into one place outline information concerning the techniques used and basic design of sample environment apparatus employed in neutron scattering experiments. Preliminary recommendations for the specimen environment programme of the SNS are presented. The general conclusion reached is that effort should be devoted towards improving reliability and efficiency of operation of specimen environment apparatus and developing systems which are robust and easy to use, rather than achieving performance at the limits of technology. (author)

  11. Crack propagation under thermal cycling loading inducing a thermal gradient in the specimen thickness

    International Nuclear Information System (INIS)

    Le, H.N.

    2009-05-01

    This study aims to figure out the crack growth phenomenon by thermal fatigue induced by thermal gradient through thickness of specimen. Firstly, an experimental facility has been developed: a rectangular parallelepiped specimen is subjected to thermal cycling between 350 C and 100 C; the specimen is freed to expand and contract. Two semi-circular notches (0,1 mm depth and 4 mm length) have been machined on the surface of the specimen. A series of interrupted tests has been carried out to characterize and quantify the crack growth in depth and surface of the pre-existing crack. Next, a three-dimensional crack growth simulation has been implemented in ABAQUS. Automation using Python was used to simulate the propagation of a crack under thermal cycling, with re-meshing at crack front after each calculation step. No assumption has been taken on the crack front during the crack propagation. A comparison with test results showed very good agreement on the evolution of crack front shape and on the kinetics of propagation on the edge and the heart of pre-existing crack. An analytical approach was also developed based on the calculation of stress intensity factors (SIC). A two-dimensional approach was first introduced enabling us to better understand the influence of various thermal and geometric parameters. Finally, a three dimensional approach, with an elliptical assumption crack shape during the propagation, leading to a prediction of crack growth on the surface and in depth which is very similar to that obtained numerically, but with computational time much lower. (author)

  12. Specimen aspect ratio and progressive field strain development of sandstone under uniaxial compression by three-dimensional digital image correlation

    Directory of Open Access Journals (Sweden)

    H. Munoz

    2017-08-01

    Full Text Available The complete stress–strain characteristics of sandstone specimens were investigated in a series of quasi-static monotonic uniaxial compression tests. Strain patterns development during pre- and post-peak behaviours in specimens with different aspect ratios was also examined. Peak stress, post-peak portion of stress–strain, brittleness, characteristics of progressive localisation and field strain patterns development were affected at different extents by specimen aspect ratio. Strain patterns of the rocks were obtained by applying three-dimensional (3D digital image correlation (DIC technique. Unlike conventional strain measurement using strain gauges attached to specimen, 3D DIC allowed not only measuring large strains, but more importantly, mapping the development of field strain throughout the compression test, i.e. in pre- and post-peak regimes. Field strain development in the surface of rock specimen suggests that strain starts localising progressively and develops at a lower rate in pre-peak regime. However, in post-peak regime, strains increase at different rates as local deformations take place at different extents in the vicinity and outside the localised zone. The extent of localised strains together with the rate of strain localisation is associated with the increase in rate of strength degradation. Strain localisation and local inelastic unloading outside the localised zone both feature post-peak regime.

  13. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  14. An electronic specimen collection protocol schema (eSCPS). Document architecture for specimen management and the exchange of specimen collection protocols between biobanking information systems.

    Science.gov (United States)

    Eminaga, O; Semjonow, A; Oezguer, E; Herden, J; Akbarov, I; Tok, A; Engelmann, U; Wille, S

    2014-01-01

    The integrity of collection protocols in biobanking is essential for a high-quality sample preparation process. However, there is not currently a well-defined universal method for integrating collection protocols in the biobanking information system (BIMS). Therefore, an electronic schema of the collection protocol that is based on Extensible Markup Language (XML) is required to maintain the integrity and enable the exchange of collection protocols. The development and implementation of an electronic specimen collection protocol schema (eSCPS) was performed at two institutions (Muenster and Cologne) in three stages. First, we analyzed the infrastructure that was already established at both the biorepository and the hospital information systems of these institutions and determined the requirements for the sufficient preparation of specimens and documentation. Second, we designed an eSCPS according to these requirements. Finally, a prospective study was conducted to implement and evaluate the novel schema in the current BIMS. We designed an eSCPS that provides all of the relevant information about collection protocols. Ten electronic collection protocols were generated using the supplementary Protocol Editor tool, and these protocols were successfully implemented in the existing BIMS. Moreover, an electronic list of collection protocols for the current studies being performed at each institution was included, new collection protocols were added, and the existing protocols were redesigned to be modifiable. The documentation time was significantly reduced after implementing the eSCPS (5 ± 2 min vs. 7 ± 3 min; p = 0.0002). The eSCPS improves the integrity and facilitates the exchange of specimen collection protocols in the existing open-source BIMS.

  15. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  16. Catalog of insect type specimens preserved at the Kunming Institute of Zoology, Chinese Academy of Science with corrections of some specimens.

    Science.gov (United States)

    Li, Kai-Qin; Wang, Yun-Zhen; Dong, Da-Zhi; Zhang, Li-Kun

    2015-09-18

    This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3 412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.

  17. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  18. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  19. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  20. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  1. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  2. Measurement on the density resolution of industrial computerized tomography by using disc specimen with holes

    International Nuclear Information System (INIS)

    Tian, Y.; Gao, D.; Zhang, W.; Xia, Z.; Yang, C.

    2004-01-01

    Several ways mainly used for measuring the density resolution of industrial computerized tomography (ICT) are briefly introduced. Based on the equivalent conversion between volume variation and density variation, a kind of disc specimen with holes is designed to measure the density resolution of ICT. In this experiment, a kind of high quality polymethyl methacylate (PMMA) is selected to make specimens with diameter of 250mm, in which six sets of holes with diameter separately 0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, and 3.0mm are distributed in the radial directions with interval of 60 o between two neighboring sets, and in the same set, the distances of holes departing the center of the specimen are respectively 20mm, 40mm, 60mm, 80mm, and 100mm. The experiment shows that the method is sensitive, simple, flexible, and practical. About 0.2% density resolution of region of interest (ROI) with diameter 20mm can be verified, the relationship between CT value of ROI and its position can be obtained, and at the same time the spatial resolution of ICT can be measured in high quality. (author)

  3. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  4. In vitro ciprofloxacin resistance patterns of gram positive bacteria isolated from clinical specimens in a teaching hospital in Saudi Arabia

    International Nuclear Information System (INIS)

    Akhtar, N.; Alzahrani, A.; Obeid, O.El-Treify; Dassal, D.

    2009-01-01

    Over the last few decades the ever-increasing level of bacterial resistance to antimicrobials has been a cause of worldwide concern. Fluoroquinolones, particularly ciprofloxacin has been used indiscriminately for both gram-positive and gram-negative bacterial infections. The increased use of ciprofloxacin has led to a progressive loss of bacterial susceptibility to this antibiotic. Therefore it is necessary to have update knowledge of resistance pattern of bacteria to this antibiotic so that alternate appropriate antibiotics can be used for ciprofloxacin-resistant bacterial infections. Objective: To evaluate the trends of ciprofloxacin resistance pattern in commonly isolated gram positive bacteria over time in a Saudi Arabian teaching hospital. Methods: A retrospective analysis was carried out for ciprofloxacin susceptibility patterns of 5534 isolates of gram-positive bacteria isolated from clinical specimens submitted to microbiology laboratories at King Fahd Hospital of the University (KFHU), Al-Khobar, Saudi Arabia during the period from January 2002 to August 2005. Results: Increase in ciprofloxacin resistance rates with some fluctuations, among these isolates, were observed. For Staphylococcus aureus, it varied from 4.62, 1.83, 7.01 and 3.98%, methicillin resistant Staphylococcus aureus (MRSA) 97.92, 97.75, 87.01 and 88.26%, Streptococcus pyogenes 5.35, 4.47, 14.44 and 3.53% during the years 2002, 2003, 2004 and 2005 respectively. Cirprofloxacin resistance during the years 2002, 2004 and 2005 for other isolates was as follows: Streptococcus pneumoniae, 30.23, 23.02 and 26.47%; enterococcus group D, 43.05, 20.68 and 57.03% and non-enterococcus group D, 62.96, 76.92 and 87.50% respectively. Conclusion: Ciprofloxacin resistance in gram positive bacterial clinical isolates particularly Staphylococcus aureus, methicillin resistant Staphylococcus aureus (MRSA) enterococcus group D, and non-enterococcus group D, has greatly increased and ciprofloxacin no more remains

  5. Fracture toughness assessment of in-service aged primary circuit elbows using mini C(T) specimens taken from outer skin

    International Nuclear Information System (INIS)

    Jayet-Gendrot, S.; Meylogan, T.; Ould, P.

    1995-05-01

    Type CF8M cast duplex stainless steels used in the primary circuit elbows of pressurized water reactors are subject to thermal aging embrittlement at their service temperature, around 300 deg. C. This phenomenon affects their fracture toughness properties. In order to assess the residual fracture toughness of these elbows, estimations are made through predictive formulae based on chemical composition and aging conditions, which provide safe values. However, in the case of the most sensitive materials, it is important to obtain more accurate estimations. A new method of determination was thus considered, based on the testing of mini-CT specimens taken from the skin of in-service elbows. The feasibility of using mini-CT specimens to evaluate the tearing resistance of cast duplex stainless steels seems at first sight difficult, in particular because of the very coarse metallurgical structure of these steels: will small specimens be representative of larger volumes (mainly regular T-CT specimens) and will they not induce too much scatter ? In order to answer such questions, an experimental validation program has been undertaken: the completed program shows that the method is relevant and leads to proposed guidelines which aim at optimizing the experimental results analysis. Then the method is applied to an in-service elbow: the results obtained are found to be in good agreement with the toughness estimations given by our predictive formulae. This subsequently contributes to the validation of the general methodology used for the justification of French primary circuit elbows. (authors). 7 refs., 4 figs., 5 tabs

  6. Ultrastructural study of the mycelial phase of clinical isolates of Sporothrix schenckii obtained from feline, canine and human cases of sporotrichosis

    Directory of Open Access Journals (Sweden)

    Isabel Martins Madrid

    2011-09-01

    Full Text Available Using transmission electron microscopy, we studied the presence of melanin and cell wall thickness of clinical isolates of Sporothrix schenckii obtained from cats, dogs and humans as compared to reference strains. We detected differences regarding presence of the melanin among the clinical isolates of S. schenckii and a correlation between presence of melanin and cell wall thickness.

  7. 21 CFR 866.2900 - Microbiological specimen collection and transport device.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices... microbiological specimen collection and transport device is a specimen collecting chamber intended for medical...

  8. Standard practice for fracture testing with surface-crack tension specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material. 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined. 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate pu...

  9. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M. [Charite, Berlin (Germany). Radiology

    2012-07-15

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  10. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.

    Science.gov (United States)

    Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M

    2012-07-01

    Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    International Nuclear Information System (INIS)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M.

    2012-01-01

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  12. Imaging of concrete specimens using inverse synthetic aperture radar

    International Nuclear Information System (INIS)

    Rhim, Hong C.; Buyukozturk, Oral

    2000-01-01

    Radar Measurement results of laboratory size concrete specimens are presented in this paper. The purpose of this research work is to study various aspects of the radar method in an effort to develop an improved radar system for nondestructive testing of concrete structures. The radar system used for the study is an Inverse Synthetic Aperture Radar (ISAR), which is capable of transmitting microwaves at three different frequency ranges of 2-3.4, 3.4-5.8, and 8-12 GHz. Radar measurement setup is such that the radar is locates 14.4 m away from a concrete target to satisfy a far-field criterion. The concrete target is rotated for 20 degrees during the measurements for the generation of two-dimensional (cross-range) imagery. Concrete targets used for the measurements have the dimensions of 305 mm (width)x305 mm (height)x92 mm (thickness) with different inside configurations. Comparisons are made for dry and wet specimens, specimens with and without inclusions. Each specimen is made to model various situations that a concrete structure can have in reality. Results show that center frequency, frequency bandwidth, and polarization of the incident wave have different effects on identifying the thickness or inclusions inside concrete specimens. Results also suggest that a certain combination of measurement parameters is suitable for a specific application area. Thus, measurement parameters can be optimized for a specific problem. The findings are presented and discussed in details in the paper. Signal processing schemes implemented for imaging of the specimens are also discussed

  13. Ex vivo MRI evaluation of prostate cancer: Localization and margin status prediction of prostate cancer in fresh radical prostatectomy specimens.

    Science.gov (United States)

    Heidkamp, Jan; Hoogenboom, Martijn; Kovacs, Iringo E; Veltien, Andor; Maat, Arie; Sedelaar, J P Michiel; Hulsbergen-van de Kaa, Christina A; Fütterer, Jurgen J

    2018-02-01

    To investigate the ability of high field ex vivo magnetic resonance imaging (MRI) to localize prostate cancer (PCa) and to predict the margin status in fresh radical prostatectomy (RP) specimens using histology as the reference standard. This Institutional Review Board (IRB)-approved study had written informed consent. Patients with biopsy-proved PCa and a diagnostic multiparametric 3T MRI examination of the prostate prior to undergoing RP were prospectively included. A custom-made container provided reference between the 7T ex vivo MRI obtained from fresh RP specimens and histological slicing. On ex vivo MRI, PCa was localized and the presence of positive surgical margins was determined in a double-reading session. These findings were compared with histological findings obtained from completely cut, whole-mount embedded, prostate specimens. In 12 RP specimens, histopathology revealed 36 PCa lesions, of which 17 (47%) and 20 (56%) were correlated with the ex vivo MRI in the first and second reading session, respectively. Nine of 12 (75%) index lesions were localized in the first session, in the second 10 of 12 (83%). Seven and 8 lesions of 11 lesions with Gleason score >6 and >0.5 cc were localized in the first and second session, respectively. In the first session none of the four histologically positive surgical margins (sensitivity 0%) and 9 of 13 negative margins (specificity 69%) were detected. In second session the sensitivity and specificity were 25% and 88%, respectively. Ex vivo MRI enabled accurate localization of PCa in fresh RP specimens, and the technique provided information on the margin status with high specificity. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:439-448. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Study on fatigue strength of specimens with stress concentrators accounting for inelastic cyclic strains

    International Nuclear Information System (INIS)

    Troshchenko, V.T.; Khamaza, L.A.; Mishchenko, Yu.D.

    1978-01-01

    A possibility of plotting the fatigue curves for structural elements with stress concentrators was examined according to the results of testing smooth specimens made of 1Kh2M steel. The technique has been suggested, based on using the Neuber formula, while taking into account the dependence of the effective coefficient of stresses concentration on the number of cycles prior to failure. A good agreement between the calculated and the experimental data has been obtained

  15. Microbiological and biochemical studies on certain antibiotic-resistant bacteria isolated from certain clinical specimens

    Energy Technology Data Exchange (ETDEWEB)

    Nada, H M.AL.M. [National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    Infection is a dynamic process involving invasion of the body by pathogenic microorganisms and reactions of the tissues to microorganisms and their toxins. Pathogenic microorganisms isolated from clinical samples are of great threat to human health.The outcome of an infection depends on the virulence of the pathogen and the relative degree of resistance or susceptibility to antimicrobial chemotherapy. Antimicrobial agents interfere with specific processes that are essential for growth and division.Development of antibiotic resistance in bacteria is a problem of great concern. The high prevalence of resistant bacteria seems to be related to uncontrolled usage of antibiotics. B-lactamases are the most common cause of bacterial resistance to B-lactam antimicrobial agents, and it is one of the most important reason for increasing the resistance in pathogenic bacteria against some antibiotics especially those acting on inhibition of cell wall synthesis. One hundred and seven clinical samples and specimens were collected from public, private hospitals and National Cancer Institute (NCI) in Cairo, Egypt. Out of them 72 cases positive for microbial infection. Twelve cases were showed mixed infection. Eighty four isolates of pathogenic bacteria and yeast were collected from single and mixed culture. Susceptibilities of the isolates to 20 different antimicrobial agents were determined according to Kirby-Bauer method. Nine multi-drug resistant gram-negative bacterial strains were identified by (Micro Scan WalkAway 96 SI System). Six of them urine isolates, 2 wound (pus) isolates and one sputum isolate. The identified strains were exposed to in-vitro gamma irradiation at dose level of 24.4 Gy, which is biologically equivalent to the fractionated multiple therapeutic dose used in the protocol of cancer treatment of some patients. The antimicrobial susceptibility of the nine multi-drug resistant strains were carried out by disk diffusion method before and after irradiation

  16. Microbiological and biochemical studies on certain antibiotic-resistant bacteria isolated from certain clinical specimens

    International Nuclear Information System (INIS)

    Nada, H.M.AL.M.

    2008-01-01

    Infection is a dynamic process involving invasion of the body by pathogenic microorganisms and reactions of the tissues to microorganisms and their toxins. Pathogenic microorganisms isolated from clinical samples are of great threat to human health.The outcome of an infection depends on the virulence of the pathogen and the relative degree of resistance or susceptibility to antimicrobial chemotherapy. Antimicrobial agents interfere with specific processes that are essential for growth and division.Development of antibiotic resistance in bacteria is a problem of great concern. The high prevalence of resistant bacteria seems to be related to uncontrolled usage of antibiotics. B-lactamases are the most common cause of bacterial resistance to B-lactam antimicrobial agents, and it is one of the most important reason for increasing the resistance in pathogenic bacteria against some antibiotics especially those acting on inhibition of cell wall synthesis. One hundred and seven clinical samples and specimens were collected from public, private hospitals and National Cancer Institute (NCI) in Cairo, Egypt. Out of them 72 cases positive for microbial infection. Twelve cases were showed mixed infection. Eighty four isolates of pathogenic bacteria and yeast were collected from single and mixed culture. Susceptibilities of the isolates to 20 different antimicrobial agents were determined according to Kirby-Bauer method. Nine multi-drug resistant gram-negative bacterial strains were identified by (Micro Scan WalkAway 96 SI System). Six of them urine isolates, 2 wound (pus) isolates and one sputum isolate. The identified strains were exposed to in-vitro gamma irradiation at dose level of 24.4 Gy, which is biologically equivalent to the fractionated multiple therapeutic dose used in the protocol of cancer treatment of some patients. The antimicrobial susceptibility of the nine multi-drug resistant strains were carried out by disk diffusion method before and after irradiation

  17. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    Science.gov (United States)

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-04-12

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  18. Improved PID control for triaxial testing liquefied specimen

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  19. Failed PCR of Ganoderma type specimens affects nomenclature.

    Science.gov (United States)

    Paterson, R R M; Lima, N

    2015-06-01

    The nomenclature of Ganoderma used as a Chinese medicine is debated. A group of researchers could not amplify the DNA of type specimens and concluded the DNA was degraded irreparably. New topotypes were used as the type specimens which was premature. The use of internal amplification controls is recommended to determine if other factors were involved as alternative explanations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Monolithic integration of nanoscale tensile specimens and MEMS structures

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet; Kysar, Jeffrey W

    2013-01-01

    Nanoscale materials often have stochastic material properties due to a random distribution of material defects and an insufficient number of defects to ensure a consistent average mechanical response. Current methods to measure the mechanical properties employ MEMS-based actuators. The nanoscale specimens are typically mounted manually onto the load platform, so the boundary conditions have random variations, complicating the experimental measurement of the intrinsic stochasticity of the material properties. Here we show methods for monolithic integration of a nanoscale specimen co-fabricated with the loading platform. The nanoscale specimen is gold with dimensions of ∼40 nm thickness, 350 ± 50 nm width, and 7 μm length and the loading platform is an interdigitated electrode electrostatic actuator. The experiment is performed in a scanning electron microscope and digital image correlation is employed to measure displacements to determine stress and strain. The ultimate tensile strength of the nanocrystalline nanoscale specimen approaches 1 GPa, consistent with measurements made by other nanometer scale sample characterization methods on other material samples at the nanometer scale, as well as gold samples at the nanometer scale. The batch-compatible microfabrication method can be used to create nominally identical nanoscale specimens and boundary conditions for a broad range of materials. (paper)

  1. Increasing the efficiency of digitization workflows for herbarium specimens.

    Science.gov (United States)

    Tulig, Melissa; Tarnowsky, Nicole; Bevans, Michael; Anthony Kirchgessner; Thiers, Barbara M

    2012-01-01

    The New York Botanical Garden Herbarium has been databasing and imaging its estimated 7.3 million plant specimens for the past 17 years. Due to the size of the collection, we have been selectively digitizing fundable subsets of specimens, making successive passes through the herbarium with each new grant. With this strategy, the average rate for databasing complete records has been 10 specimens per hour. With 1.3 million specimens databased, this effort has taken about 130,000 hours of staff time. At this rate, to complete the herbarium and digitize the remaining 6 million specimens, another 600,000 hours would be needed. Given the current biodiversity and economic crises, there is neither the time nor money to complete the collection at this rate.Through a combination of grants over the last few years, The New York Botanical Garden has been testing new protocols and tactics for increasing the rate of digitization through combinations of data collaboration, field book digitization, partial data entry and imaging, and optical character recognition (OCR) of specimen images. With the launch of the National Science Foundation's new Advancing Digitization of Biological Collections program, we hope to move forward with larger, more efficient digitization projects, capturing data from larger portions of the herbarium at a fraction of the cost and time.

  2. The process and challenges of obtaining and sustaining clinical placements for nursing and allied health students.

    Science.gov (United States)

    Taylor, Christine; Angel, Liz; Nyanga, Lucy; Dickson, Cathy

    2017-10-01

    To describe the process and challenges from a project that aimed to develop processes, source new placements and place students primarily in the discipline of nursing, but also occupational therapy, physiotherapy, podiatry, social work, and speech therapy. Clinical experience in health facilities is an essential element of health professional education, yet globally, there is a lack of clinical placements to meet demands. Educational providers are seeking placements in nontraditional facilities, yet little has been reported on the challenges in the process of procuring clinical placements. The project used a descriptive approach within a quality implementation framework. The project was guided by the quality implementation framework that included four critical steps: considerations of the host setting, structuring the implementation, supporting the implementation and improving future applications. A total of 115 new student placements were finalised across six health disciplines, including elderly care, nongovernment organisations and general practice. Sixty-two nursing students were placed in the new placements during the project. Challenges included communication, the time-consuming nature of the process and 'gatekeeping' blocks to obtaining placements. Recommendations included the importance of personal interaction in developing and maintaining relationships, and the need for clear communication processes and documentation. Potential areas for research are also given. There is great potential for growth in establishing new placements outside the traditional placement facilities for nursing and allied health and for expanding already existing nonhospital placements. Clinical professional experiences are essential to any nursing or allied health programme. There is an increasing demand for, and global lack of, clinical placements for nursing and allied health students. The results provide nursing and allied health educators and managers a framework for planning

  3. Comparison of Thellier-type and multispecimen absolute paleointensities obtained on Miocene to historical lava flows from Lanzarote (Canary Islands, Spain)

    Science.gov (United States)

    Calvo-Rathert, M.; Morales, J.; Carrancho, Á.; Gogichaishvili, A.

    2015-12-01

    A paleomagnetic, rock-magnetic and paleointensity study has been carried out on 16 Miocene, Pleistocene, Quaternary and historical lava flows from Lanzarote (Canary Islands, Spain) with two main goals: (i) Compare paleointensity results obtained with two different techniques (Thellier-type and multispecimen) and (ii) obtain new paleointensity data. Initial rock-magnetic experiments on selected samples from each site were carried out to find out the carriers of remanence and to determine their thermal stability and grain size. They included the measurement of thermomagnetic curves, hysteresis parameters and IRM acquisition curves. Mostly reversible but also non-reversible curves were recorded in thermomagnetic experiments, with low-Ti titanomagnetite being the main carrier of remanence in most studied flows. Paleomagnetic analysis showed in most cases a single component and a characteristic component could be determined in 15 flows, all displaying normal-polarity. 83 samples from 13 flows were chosen for paleointensity experiments. In order to compare paleointensity results from exactly the same samples, they were cut into smaller specimens so that in each case a specimen was available to be used for a Thellier-type paleointensity determination, another one for a multispecimen paleointensity experiment and another one for rock-magnetic experiments. Thermomagnetic curves could be therefore measured on all samples subjected to paleointensity experiments. Thellier-type paleointensity determinations were performed with the Coe method between room temperature and 581°C on small (0.9 cm diameter and 1 to 2.5 cm length) specimens. After heating, samples were left cooling down naturally during several hours. Multispecimen paleointensity determinations were carried out using the method of Dekkers and Böhnel. The aforementioned sub-samples were cut into 8 specimens and pressed into salt pellets in order to obtain standard cylindrical specimens. A set of eight experiments

  4. Centrifuge-operated specimen staining method and apparatus

    Science.gov (United States)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  5. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  6. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    Science.gov (United States)

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  7. Maintaining respect and fairness in the usage of stored shared specimens.

    Science.gov (United States)

    Mduluza, Takafira; Midzi, Nicholas; Duruza, Donold; Ndebele, Paul

    2013-01-01

    Every year, research specimens are shipped from one institution to another as well as across national boundaries. A significant proportion of specimens move from poor to rich countries. Concerns are always raised on the future usage of the stored specimens shipped to research institutions from developing countries. Creating awareness of the processes is required in all sectors involved in biomedical research. To maintain fairness and respect in sharing biomedical specimens and research products requires safeguarding by Ethics Review Committees in both provider and recipient institutions. Training in basic ethical principles in research is required to all sectors involved in biomedical research so as to level up the research playing field. By agreeing to provide specimens, individuals and communities from whom samples are collected would have placed their trust and all ensuing up-keep of the specimens to the researchers. In most collaborative set-up, laid down material transfer agreements are negotiated and signed before the shipment of specimens. Researchers, research ethics committees (RECs) and institutions in the countries of origin are supposed to serve as overseers of the specimens. There is need to advocate for honesty in sample handling and sharing, and also need to oversee any written commitments by researchers, RECs and institutions at source as well as in recipient institution. Commitments from source RECs and Institutional Review Boards (IRBs) and in the receiving institution on overseeing the future usage of stored specimens are required; including the ultimate confirmation abiding by the agreement. Training in ethical issues pertaining to sample handling and biomedical research in general is essential at all levels of academic pursuit. While sharing of biological specimens and research data demands honesty and oversight by ethical regulatory agents from both institutions in developing country and recipient institutions in developed countries. Archiving

  8. 50 CFR 14.24 - Scientific specimens.

    Science.gov (United States)

    2010-10-01

    ..., POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS... international mail system. Provided, that this exception will not apply to any specimens or parts thereof taken...

  9. Evaluation of A-1 reactor heavy-water calandria specimens

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  10. Review of forensically important entomological specimens collected from human cadavers in Malaysia (2005-2010).

    Science.gov (United States)

    Kavitha, Rajagopal; Nazni, Wasi Ahmad; Tan, Tian Chye; Lee, Han Lim; Azirun, Mohd Sofian

    2013-07-01

    Forensic entomological specimens collected from human decedents during crime scene investigations in Malaysia in the past 6 years (2005-2010) are reviewed. A total of 80 cases were recorded and 93 specimens were collected. From these specimens, 10 species of cyclorrphagic flies were identified, consisting of Chrysomya rufifacies (Macquart) -38 specimens (40.86%), Chrysomya megacephala (Fabricius) -36 specimens (38.70%), Chrysomya villeneuvi (Patton) -2 specimens (2.15%), Chrysomya nigripes (Aubertin) -2 specimens (2.15%), Chrysomya pinguis (Walker) -1 specimen (1.08%), Hermetia illucens (Linnaeus) -1 specimen (1.08%), Hemipyrellia liguriens (Wiedemann) -5 specimens (5.37%), Synthesiomyia nudiseta (Wulp) -1 specimen (1.08%), Megaselia scalaris (Loew)-1 specimen (1.08%) and Sarcophaga ruficornis (Fabricius) -4 specimens (4.30%). In two specimens (2.15%), the maggots were not identifiable. Ch. megacephala and Ch. rufifacies were the commonest species found in human decedents from three different ecological habitats. S. nudiseta is an uncommon species found only on human cadavers from indoors. A total of 75 cases (93.75%) had a single fly infestation and 5 cases (6.25%) had double fly infestation. In conclusion, although large numbers of fly species were found on human decedents, the predominant species are still those of Chrysomya. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  11. Multicenter Clinical Evaluation of the Alere i Respiratory Syncytial Virus Isothermal Nucleic Acid Amplification Assay.

    Science.gov (United States)

    Hassan, Ferdaus; Hays, Lindsay M; Bonner, Aleta; Bradford, Bradley J; Franklin, Ruffin; Hendry, Phyllis; Kaminetsky, Jed; Vaughn, Michael; Cieslak, Kristin; Moffatt, Mary E; Selvarangan, Rangaraj

    2018-03-01

    The Alere i respiratory syncytial virus (RSV) assay is an isothermal nucleic acid amplification test capable of detecting RSV directly from respiratory specimens, with results being available in ≤13 min after test initiation. The objective of this study was to evaluate the performance characteristics of the Alere i RSV assay in a point-of-care setting by using direct nasopharyngeal (NP) swab specimens (direct NP) and nasopharyngeal swab specimens eluted and transported in viral transport medium (VTM NP). The study was a prospective, multicenter, clinical trial conducted at 9 sites across the United States to evaluate the clinical performance of the Alere i RSV assay with respiratory specimens obtained from both children (age, 60 years). The performance of the Alere i RSV assay was compared with that of the reference method, the Prodesse ProFlu+ real-time reverse transcriptase PCR (RT-PCR) assay. All specimens with discrepant test results were tested further by a second FDA-cleared PCR assay (the Verigene respiratory virus plus nucleic acid test; Luminex Inc., TX). A total of 554 subjects with signs and symptoms of respiratory infections were enrolled, and respiratory samples were collected in this study. In comparison with the ProFlu+ real-time RT-PCR, the overall sensitivity and specificity of Alere i RSV assay for the detection of RSV were 98.6% (95% confidence interval [CI], 94.4 to 99.7%) and 98.0% (95% CI, 95.8 to 99.1%), respectively, for direct NP and 98.6% (95% CI, 94.4 to 99.7%) and 97.8% (95% CI, 95.5 to 98.9%), respectively, for VTM NP. The Alere i RSV is a highly sensitive and specific molecular assay ideal for rapid RSV detection in patients in the point-of-care setting due to its minimal hands-on time and rapid result availability. Copyright © 2018 American Society for Microbiology.

  12. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  13. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  14. Design of creep machine and creep specimen chamber for carrying out creep tests in flowing liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in; Laha, K.; Sakthy, S.; Mathew, M.D.; Jayakumar, T.

    2014-02-15

    Highlights: • Design of a lever type creep machine for carrying out creep test in flowing sodium. • Leveling of lever during creep was achieved by automated movement of fulcrum. • Design of creep chamber for providing constant sodium flow rate across creep specimen. • Minimum use of bellow in chamber for sodium containment and mechanical isolation. • Mini-lever mechanism to counter balance load reduction on specimen due to bellow stiffness. - Abstract: A creep testing system has been designed, fabricated, installed and validated for carrying out creep tests in flowing liquid sodium. The testing system consists of two sections namely creep testing machine and an environmental chamber. The testing system has the ability of (i) applying tensile load to the test specimen through a lever, (ii) monitoring continuously the creep elongation and (iii) allowing sodium to flow around the creep specimen at constant velocity. The annular space between the creep specimen and the environmental chamber has been suitably designed to maintain constant sodium flow velocity. Primary and secondary bellows are employed in the environmental chamber to (i) mechanically isolate the creep specimen, (ii) prevent the flowing sodium in contact with air and (iii) maintain an argon gas cover to the leaking sodium if any from primary bellow, with a provision to an alarm get activated by a spark plug. The lever-horizontality during creep test has been maintained by automatically lifting up the fulcrum instead of lowering down the pull rod as conventionally used. A mini lever mechanism has been incorporated in the load train to counter balance the load reduction on specimen from the changing stiffness of the bellows. The validation of the testing system has been established by carrying out creep tests on 316L(N) stainless steel at 873 K over a wide stress range and comparing the results with those obtained in air by employing the developed and conventional creep testing machines.

  15. Identification of virulence genes carried by bacteriophages obtained from clinically isolated methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Karasartova, Djursun; Cavusoglu, Zeynep Burcin; Turegun, Buse; Ozsan, Murat T; Şahin, Fikret

    2016-12-01

    Bacteriophages play an important role in the pathogenicity of Staphylococcus aureus (S. aureus) either by carrying accessory virulence factors or several superantigens. Despite their importance, there are not many studies showing the actual distribution of the virulence genes carried by the prophages obtained from the clinically isolated Staphylococcus. In this study, we investigated prophages obtained from methicillin-resistant S. aureus (MRSA) strains isolated from hospital- and community-associated (HA-CA) infections for the virulence factors. In the study, 43 phages isolated from 48 MRSA were investigated for carrying toxin genes including the sak, eta, lukF-PV, sea, selp, sek, seg, seq chp, and scn virulence genes using polymerase chain reaction (PCR) and Southern blot. Restriction fragment length polymorphism was used to analyze phage genomes to investigate the relationship between the phage profiles and the toxin genes' presence. MRSA strains isolated from HA infections tended to have higher prophage presence than the MRSA strains obtained from the CA infections (97% and 67%, respectively). The study showed that all the phages with the exception of one phage contained one or more virulence genes in their genomes with different combinations. The most common toxin genes found were sea (83%) followed by sek (77%) and seq (64%). The study indicates that prophages encode a significant proportion of MRSA virulence factors.

  16. Influence of specimen size on the creep of rock salt

    International Nuclear Information System (INIS)

    Senseny, P.E.

    1982-01-01

    Triaxial compression creep data for Avery Island dome salt are analyzed to determine the influence of specimen size on creep deformation. Laboratory experiments were performed on 50- and 100-mm-diameter specimens in the temperature range from 25 to 200 0 C and the axial stress difference range from 2.5 to 31.0 MPa. The strain-vs-time data from each test are divided into transient and steady-state components. Results of statistical analysis of these data show that transient creep of the small specimens is a stronger function of stress, temperature, and time than is transient creep of the larger specimens. Analysis of the steady-state data show no size effect, however. 14 references, 7 figures, 3 tables

  17. Laparoscopic right-sided colonic resection with transluminal colonoscopic specimen extraction

    Science.gov (United States)

    Kayaalp, Cuneyt; Kutluturk, Koray; Yagci, Mehmet Ali; Ates, Mustafa

    2015-01-01

    AIM: To study the transcolonic extraction of the proximally resected colonic specimens by colonoscopic assistance at laparoscopic colonic surgery. METHODS: The diagnoses of our patients were Crohn’s disease, carcinoid of appendix and adenocarcinoma of cecum. We preferred laparoscopic total mesocolic resections. Colon and terminal ileum were divided with endoscopic staplers. A colonoscope was placed per anal and moved proximally in the colon till to reach the colonic closed end under the laparoscopic guidance. The stump of the colon was opened with laparoscopic scissors. A snare of colonoscope was released and the intraperitoneal complete free colonic specimen was grasped. Specimen was moved in to the colon with the help of the laparoscopic graspers and pulled gently through the large bowel and extracted through the anus. The open end of the colon was closed again and the ileal limb and the colon were anastomosed intracorporeally with a 60-mm laparoscopic stapler. The common enterotomy orifice was closed in two layers with a running intracorporeal suture. RESULTS: There were three patients with laparoscopic right-sided colonic resections and their specimens were intended to remove through the remnant colon by colonoscopy but the procedure failed in one patient (adenocarcinoma) due to a bulky mass and the specimen extraction was converted to transvaginal route. All the patients had prior abdominal surgeries and had related adhesions. The operating times were 210, 300 and 500 min. The lengths of the specimens were 13, 17 and 27 cm. In our cases, there were no superficial or deep surgical site infections or any other complications. The patients were discharged uneventfully within 4-5 d and they were asymptomatic after a mean 7.6 mo follow-up (ranged 4-12). As far as we know, there were only 12 cases reported yet on transcolonic extraction of the proximal colonic specimens by colonoscopic assistance after laparoscopic resections. With our cases, success rate of the

  18. Cytogenetic and molecular characterization of Speothos venaticus specimens - doi: 10.4025/actascibiolsci.v32i4.6775 Cytogenetic and molecular characterization of Speothos venaticus specimens - doi: 10.4025/actascibiolsci.v32i4.6775

    Directory of Open Access Journals (Sweden)

    Lígia Souza Lima Silveira da Mota

    2010-11-01

    Full Text Available The bush dog (Speothos venaticus is a South American canid, included in the IBAMA (Brazilian Institute of Environment and Renewable Natural Resources official list of animals threatened with extinction, in the vulnerable category. As a preservation and conservation strategy, specimens kept in captivity by Brazilian Institutions are monitored by a management plan. In order to characterize and analyze the genetic variability of bush dog specimens, a cytogenetic analysis was carried out, and microsatellite data were also obtained through the use of 15 primers, originally developed for the domestic dog (Canis familiaris. All tested primers showed transferability and amplified fragment sizes similar to those described for the canine genome. From the total number of primers, eight were tested, and presented two polymorphic regions. Regarding cytogenetic analysis, one of the animals had chromosomal mosaicism, disqualifying it as a reproducer to form stocks. Thus, we concluded that the genetic evaluation of wild animals kept in captivity provides data that can help with the practice of exchange between different institutions, avoiding problems in the reproductive capacity of the breeding stock.The bush dog (Speothos venaticus is a South American canid, included in the IBAMA (Brazilian Institute of Environment and Renewable Natural Resources official list of animals threatened with extinction, in the vulnerable category. As a preservation and conservation strategy, specimens kept in captivity by Brazilian Institutions are monitored by a management plan. In order to characterize and analyze the genetic variability of bush dog specimens, a cytogenetic analysis was carried out, and microsatellite data were also obtained through the use of 15 primers, originally developed for the domestic dog (Canis familiaris. All tested primers showed transferability and amplified fragment sizes similar to those described for the canine genome. From the total number of

  19. Images of paraffin monolayer crystals with perfect contrast: Minimization of beam-induced specimen motion

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, R.M. [Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States); McMullan, G.; Faruqi, A.R. [MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH (United Kingdom); Henderson, R., E-mail: rh15@mrc-lmb.cam.ac.uk [MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH (United Kingdom)

    2011-01-15

    Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation of the specimen causes beam-induced charging or movement, which in turn causes blurring of the image due to image or specimen movement. In this paper, we used three different approaches to try to overcome this image-blurring problem in monolayer crystals of paraffin. Our first approach was to use an extreme form of spotscan imaging, in which a single image was assembled on film by the successive illumination of up to 50,000 spots, each of a diameter of around 7 nm. The second approach was to use the Medipix II detector with its zero-noise readout to assemble a time-sliced series of images of the same area in which each frame from a movie with up to 400 frames had an exposure of only 500 electrons. In the third approach, we simply used a much thicker carbon support film to increase the physical strength and conductivity of the support. Surprisingly, the first two methods involving dose fractionation in space or time produced only partial improvements in contrast whereas the third approach produced many virtually perfect images, where the absolute contrast predicted from the electron diffraction amplitudes was observed in the images. We conclude that it is possible to obtain consistently almost perfect images of beam-sensitive specimens if they are attached to an appropriately strong and conductive support; however great care is needed in practice and the problem remains of how to best image ice-embedded biological structures in the absence of a strong, conductive support film. -- Research Highlights: {yields}Three ideas were tested to improve the contrast of images of an organic specimen. {yields}High-resolution images of paraffin on thick carbon films can have perfect

  20. Images of paraffin monolayer crystals with perfect contrast: Minimization of beam-induced specimen motion

    International Nuclear Information System (INIS)

    Glaeser, R.M.; McMullan, G.; Faruqi, A.R.; Henderson, R.

    2011-01-01

    Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation of the specimen causes beam-induced charging or movement, which in turn causes blurring of the image due to image or specimen movement. In this paper, we used three different approaches to try to overcome this image-blurring problem in monolayer crystals of paraffin. Our first approach was to use an extreme form of spotscan imaging, in which a single image was assembled on film by the successive illumination of up to 50,000 spots, each of a diameter of around 7 nm. The second approach was to use the Medipix II detector with its zero-noise readout to assemble a time-sliced series of images of the same area in which each frame from a movie with up to 400 frames had an exposure of only 500 electrons. In the third approach, we simply used a much thicker carbon support film to increase the physical strength and conductivity of the support. Surprisingly, the first two methods involving dose fractionation in space or time produced only partial improvements in contrast whereas the third approach produced many virtually perfect images, where the absolute contrast predicted from the electron diffraction amplitudes was observed in the images. We conclude that it is possible to obtain consistently almost perfect images of beam-sensitive specimens if they are attached to an appropriately strong and conductive support; however great care is needed in practice and the problem remains of how to best image ice-embedded biological structures in the absence of a strong, conductive support film. -- Research Highlights: →Three ideas were tested to improve the contrast of images of an organic specimen. →High-resolution images of paraffin on thick carbon films can have perfect contrast

  1. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  2. 3D printing from microfocus computed tomography (micro-CT) in human specimens: education and future implications.

    Science.gov (United States)

    Shelmerdine, Susan C; Simcock, Ian C; Hutchinson, John Ciaran; Aughwane, Rosalind; Melbourne, Andrew; Nikitichev, Daniil I; Ong, Ju-Ling; Borghi, Alessandro; Cole, Garrard; Kingham, Emilia; Calder, Alistair D; Capelli, Claudio; Akhtar, Aadam; Cook, Andrew C; Schievano, Silvia; David, Anna; Ourselin, Sebastian; Sebire, Neil J; Arthurs, Owen J

    2018-06-14

    Microfocus CT (micro-CT) is an imaging method that provides three-dimensional digital data sets with comparable resolution to light microscopy. Although it has traditionally been used for non-destructive testing in engineering, aerospace industries and in preclinical animal studies, new applications are rapidly becoming available in the clinical setting including post-mortem fetal imaging and pathological specimen analysis. Printing three-dimensional models from imaging data sets for educational purposes is well established in the medical literature, but typically using low resolution (0.7 mm voxel size) data acquired from CT or MR examinations. With higher resolution imaging (voxel sizes below 1 micron, printing of micro-CT imaged specimens can provide insight into craniofacial surgical applications, developmental cardiac anatomy, placental imaging, archaeological remains and high-resolution bone imaging. We conclude with other potential future usages of this emerging technique.

  3. Increasing the efficiency of digitization workflows for herbarium specimens

    Directory of Open Access Journals (Sweden)

    Melissa Tulig

    2012-07-01

    Full Text Available The New York Botanical Garden Herbarium has been databasing and imaging its estimated 7.3 million plant specimens for the past 17 years. Due to the size of the collection, we have been selectively digitizing fundable subsets of specimens, making successive passes through the herbarium with each new grant. With this strategy, the average rate for databasing complete records has been 10 specimens per hour. With 1.3 million specimens databased, this effort has taken about 130,000 hours of staff time. At this rate, to complete the herbarium and digitize the remaining 6 million specimens, another 600,000 hours would be needed. Given the current biodiversity and economic crises, there is neither the time nor money to complete the collection at this rate.Through a combination of grants over the last few years, The New York Botanical Garden has been testing new protocols and tactics for increasing the rate of digitization through combinations of data collaboration, field book digitization, partial data entry and imaging, and optical character recognition (OCR of specimen images. With the launch of the National Science Foundation’s new Advancing Digitization of Biological Collections program, we hope to move forward with larger, more efficient digitization projects, capturing data from larger portions of the herbarium at a fraction of the cost and time.

  4. [Application of polyguanidine solution for fixation of biological and anatomical specimens].

    Science.gov (United States)

    Anichkov, N M; Danilova, I A; Riabinin, I A; Kipenko, A V

    2010-01-01

    A new method for fixation of biological material is described, and its effectiveness is compared to that one of formalin fixation. As an embalming agent, polyhexamethylenguanidine (PHMG) hydrochloride was used. Using the proposed method of fixation, the anatomical and histological preparations of human organs and of chick embryos at developmental 12 days, were produced. The anatomical preparations obtained show the appearance, similar to that of the recently removed organs. Histological preparations were free from significant distortions of the microscopic characteristics of the specimens, which are typical to the material fixed with formalin. The results of the study suggest the possibility of PHMG application in the morphological studies.

  5. Catalogue of test specimens for non-destructive examination

    International Nuclear Information System (INIS)

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  6. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  7. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    Science.gov (United States)

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  8. Guidebook for the fabrication of non-destructive testing (NDT) test specimens

    International Nuclear Information System (INIS)

    2001-01-01

    Non-destructive testing (NDT) test specimens constitute a very important part of training and certification of NDT personnel and are important for carrying out actual inspection and testing, and for achieving international harmonization of NDT practices. The IAEA organized an advisory group of experts to develop a Guidebook for Fabrication of NDT Test Specimens. The experts consulted the ISO/FDIS 9712-1999 requirements for training and certification of personnel and the suitability of various types of NDT test specimens that are needed to meet such requirements This guidebook presents a set of NDT test specimens, and the methodology and procedures for their fabrication

  9. Detection of radiation-induced changes in electrochemical properties of austenitic stainless steels using miniaturized specimens and the single-loop electrochemical potentiokinetic reactivation method

    International Nuclear Information System (INIS)

    Inazumi, T.; Bell, G.E.C.; Kenik, E.A.; Kiuchi, K.

    1993-01-01

    Single-loop electrochemical potentiokinetic reactivation testing of miniaturized (TEM) specimens can provide reliable data comparable to data obtained with larger specimens. Significant changes in electrochemical properties (increased reactivation current and Flade potential) were detected for PCA and type 316 stainless steels irradiated at 200--420 degrees C up to 7--9 dpa. Irradiations in the FFTF Materials Open Test Assembly and in the Oak Ridge Research Reactor are reported on. 45 figs., 5 tabs., 52 refs

  10. Determination of necking time in tensile test specimens, under high-temperature creep conditions, subjected to distribution of stresses over the cross-section

    Science.gov (United States)

    Lokoshchenko, A.; Teraud, W.

    2018-04-01

    The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.

  11. Significant association between renal function and amyloid-positive area in renal biopsy specimens in AL amyloidosis

    Directory of Open Access Journals (Sweden)

    Kuroda Takeshi

    2012-09-01

    Full Text Available Abstract Background The kidney is a major target organ for systemic amyloidosis that often affects the kidney including proteinura, and elevated serum creatinine (Cr. The correlation between amount of amyloid deposits and clinical parameters is not known. The aim of this study was to clarify correlation the amyloid area in all renal biopsy specimen and clinical parameters. Methods Fifty-eight patients with an established diagnosis of AL amyloidosis participated in the study. All patients showed amyloid deposits in renal biopsies. We retrospectively investigated the correlation between clinical data and amyloid occupied area in whole renal biopsy specimens. Results The area occupied by amyloid was less than 10% in 57 of the 58 patients, and was under 2% in 40. For statistical analyses, %amyloid-positive areas were transformed to common logarithmic values (Log10%amyloid. Cr showed significant correlation with Log10%amyloid and estimated glomerular filtration rate (eGFR showed the significant negative correlation. Patient age, cleatinine clearance (Ccr, blood urea nitorogen, and urinary protein was not significantly correlated with Log10%amyloid. The correlation with other clinical factors such as sex, and serum concentrations of total protein, albumin, immunoglobulins, compliments was evaluated. None of these factors significantly correlated with Log10%amyloid. According to sex- and age- adjusted multiple linear regression analysis, Log10%amyloid had significant positive association with Cr and significant negative association with eGFR. Conclusion There is significant association between amyloid-positive area in renal tissue and renal function, especially Cr and eGFR. The level of Cr and eGFR may be a marker of amount of amyloid in renal tissue.

  12. Alfredo Dugès' type specimens of amphibians and reptiles revisited.

    Science.gov (United States)

    Flores-Villela, Oscar; Ríos-Muñoz, César A; Magaña-Cota, Gloria E; Quezadas-Tapia, Néstor L

    2016-03-14

    The type specimens of amphibians and reptiles of the Museo de Historia Natural Alfredo Dugès, at the University of Guanajuato (MADUG) were reviewed following Smith & Necker's (1943) summary. Owing to this collection's eventful history and its historical importance as the oldest herpetological collection in Mexico, a review of its conservation status was needed. After many years, the collection has received proper recognition at the University of Guanajuato with a portion of the herpetological types considered "Precious Assets" of the university. We found 34 type specimens pertaining to 18 taxa; six are additional specimens to those previously reported; six herpetological types are missing, including the body of the type of Adelophis copei. All specimens are in good to reasonable condition except for the type of Rhinocheilus antonii, which has dried out completely. All specimens are illustrated to show their condition.

  13. The Diagnosis of Gastric Mucosa-associated Lymphoid Tissue Lymphoma by Flow Cytometry and Fluorescence in situ Hybridization of Biopsy Specimens.

    Science.gov (United States)

    Matsueda, Katsunori; Omote, Sizuma; Sakata, Masahiro; Fujita, Isao; Horii, Jouichiro; Toyokawa, Tatsuya

    2018-04-15

    Mucosa-associated lymphoid tissue (MALT) lymphoma and reactive inflammatory lymphoid changes are frequently difficult to distinguish based on a routine histological differential diagnosis. We were unable to diagnose gastric MALT lymphoma histologically using specimens obtained by endoscopy, although a flow cytometry (FCM) analysis demonstrated clonality of neoplastic cells by separating cells by CD45 gating. Furthermore, a fluorescence in situ hybridization (FISH) analysis showed trisomy 18. We therefore diagnosed gastric MALT lymphoma with trisomy 18. We recommend that FCM and FISH analyses of biopsy specimens be considered for diagnosing gastric MALT lymphoma if this diagnosis is suspected based on endoscopic findings.

  14. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  15. Anterolateral Ligament of the Knee Shows Variable Anatomy in Pediatric Specimens.

    Science.gov (United States)

    Shea, Kevin G; Milewski, Matthew D; Cannamela, Peter C; Ganley, Theodore J; Fabricant, Peter D; Terhune, Elizabeth B; Styhl, Alexandra C; Anderson, Allen F; Polousky, John D

    2017-06-01

    Anterior cruciate ligament (ACL) reconstruction failure rates are highest in youth athletes. The role of the anterolateral ligament in rotational knee stability is of increasing interest, and several centers are exploring combined ACL and anterolateral ligament reconstruction for these young patients. Literature on the anterolateral ligament of the knee is sparse in regard to the pediatric population. A single study on specimens younger than age 5 years demonstrated the presence of the anterolateral ligament in only one of eight specimens; therefore, much about the prevalence and anatomy of the anterolateral ligament in pediatric specimens remains unknown. We sought to (1) investigate the presence or absence of the anterolateral ligament in prepubescent anatomic specimens; (2) describe the anatomic relationship of the anterolateral ligament to the lateral collateral ligament; and (3) describe the anatomic relationship between the anterolateral ligament and the physis. Fourteen skeletally immature knee specimens (median age, 8 years; range, 7-11 years) were dissected (12 male, two female specimens). The posterolateral structures were identified in all specimens, including the lateral collateral ligament and popliteus tendon. The presence or absence of the anterolateral ligament was documented in each specimen, along with origin, insertion, and dimensions, when applicable. The relationship of the anterolateral ligament origin to the lateral collateral ligament origin was recorded. The anterolateral ligament was identified in nine of 14 specimens. The tibial attachment point was consistently located in the same region on the proximal tibia, between the fibular head and Gerdy's tubercle; however, the femoral origin of the anterolateral ligament showed considerable variation with respect to the lateral collateral ligament origin. The median femoral origin of the anterolateral ligament was 10 mm (first interquartile 6 mm, third interquartile 13) distal to the distal

  16. Specimen preparation, imaging, and analysis protocols for knife-edge scanning microscopy.

    Science.gov (United States)

    Choe, Yoonsuck; Mayerich, David; Kwon, Jaerock; Miller, Daniel E; Sung, Chul; Chung, Ji Ryang; Huffman, Todd; Keyser, John; Abbott, Louise C

    2011-12-09

    Major advances in high-throughput, high-resolution, 3D microscopy techniques have enabled the acquisition of large volumes of neuroanatomical data at submicrometer resolution. One of the first such instruments producing whole-brain-scale data is the Knife-Edge Scanning Microscope (KESM), developed and hosted in the authors' lab. KESM has been used to section and image whole mouse brains at submicrometer resolution, revealing the intricate details of the neuronal networks (Golgi), vascular networks (India ink), and cell body distribution (Nissl). The use of KESM is not restricted to the mouse nor the brain. We have successfully imaged the octopus brain, mouse lung, and rat brain. We are currently working on whole zebra fish embryos. Data like these can greatly contribute to connectomics research; to microcirculation and hemodynamic research; and to stereology research by providing an exact ground-truth. In this article, we will describe the pipeline, including specimen preparation (fixing, staining, and embedding), KESM configuration and setup, sectioning and imaging with the KESM, image processing, data preparation, and data visualization and analysis. The emphasis will be on specimen preparation and visualization/analysis of obtained KESM data. We expect the detailed protocol presented in this article to help broaden the access to KESM and increase its utilization.

  17. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  18. Thermal Cycling of Uranium Dioxide - Tungsten Cermet Fuel Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Gripshover, P.J.; Peterson, J.H.

    1969-12-08

    In phase I tungsten clad cermet fuel specimens were thermal cycled, to study the effects of fuel loading, fuel particle size, stablized fuel, duplex coatings, and fabrication techniques on dimensional stability during thermal cycling. In phase II the best combination of the factors studies in phase I were combined in one specimen for evaluation.

  19. Self-heating forecasting for thick laminate specimens in fatigue

    Science.gov (United States)

    Lahuerta, F.; Westphal, T.; Nijssen, R. P. L.

    2014-12-01

    Thick laminate sections can be found from the tip to the root in most common wind turbine blade designs. Obtaining accurate and reliable design data for thick laminates is subject of investigations, which include experiments on thick laminate coupons. Due to the poor thermal conductivity properties of composites and the material self-heating that occurs during the fatigue loading, high temperature gradients may appear through the laminate thickness. In the case of thick laminates in high load regimes, the core temperature might influence the mechanical properties, leading to premature failures. In the present work a method to forecast the self-heating of thick laminates in fatigue loading is presented. The mechanical loading is related with the laminate self-heating, via the cyclic strain energy and the energy loss ratio. Based on this internal volumetric heat load a thermal model is built and solved to obtain the temperature distribution in the transient state. Based on experimental measurements of the energy loss factor for 10mm thick coupons, the method is described and the resulting predictions are compared with experimental surface temperature measurements on 10 and 30mm UD thick laminate specimens.

  20. Development of specimen size and test rate effects on the J-integral upper transition behavior of A533B steel

    International Nuclear Information System (INIS)

    Joyce, James A.

    1988-01-01

    During the past three years a test method has been developed for dynamic testing of fracture mechanics specimens which is specifically designed for application to the upper transition temperature range. The method uses drop tower loading rates of 2.5 m/sec and obtains a J IC or a J-R curve using an analytical key curve approach verified by initial and final crack length measurements obtained from the fracture surface. A J-R curve is obtained from each specimen and contains crack growth corrections so that it is directly comparable with static results obtained in accordance with the ASTM E1152 J-R curve test method. The test procedure has been applied to A106 steel, A533B steel and US Navy HY80 and HY100 steels at temperatures from -200F to 150F. Standard 1T three point bend specimens were used for the A533B and the HY100 steel. Static test results have shown that the J at cleavage initiation (which is presently an unstandardized quantity) is specimen a/W independent throughout the ductile to brittle transition but of course demonstrates considerable statistical scatter in the vicinity of the ductile upper shelf. Dynamic J-R tests have shown an increase in J IC with test rate for most, but not for all, materials. Separation of J into elastic and plastic components shows that the elastic J component increases with test rate in a fashion consistent with the materials tensile sensitivity to test rate but the plastic J component decreases with test rate - an apparent visco-plastic phenomena. For A106 steel the plastic J decrease exceeds the elastic J increase and the upper shelf toughness falls - while the other materials have demonstrated a relatively larger increase in the elastic J component and a smaller decrease in the plastic J component giving an overall increase in upper shelf toughness. Separation of the J integral into elastic and plastic components has demonstrated that J EL is specimen scale and geometry dependent while J PL is relatively scale and geometry