WorldWideScience

Sample records for clinical dti gradient

  1. Segmentation of DTI based on tensorial morphological gradient

    Science.gov (United States)

    Rittner, Leticia; de Alencar Lotufo, Roberto

    2009-02-01

    This paper presents a segmentation technique for diffusion tensor imaging (DTI). This technique is based on a tensorial morphological gradient (TMG), defined as the maximum dissimilarity over the neighborhood. Once this gradient is computed, the tensorial segmentation problem becomes an scalar one, which can be solved by conventional techniques, such as watershed transform and thresholding. Similarity functions, namely the dot product, the tensorial dot product, the J-divergence and the Frobenius norm, were compared, in order to understand their differences regarding the measurement of tensor dissimilarities. The study showed that the dot product and the tensorial dot product turned out to be inappropriate for computation of the TMG, while the Frobenius norm and the J-divergence were both capable of measuring tensor dissimilarities, despite the distortion of Frobenius norm, since it is not an affine invariant measure. In order to validate the TMG as a solution for DTI segmentation, its computation was performed using distinct similarity measures and structuring elements. TMG results were also compared to fractional anisotropy. Finally, synthetic and real DTI were used in the method validation. Experiments showed that the TMG enables the segmentation of DTI by watershed transform or by a simple choice of a threshold. The strength of the proposed segmentation method is its simplicity and robustness, consequences of TMG computation. It enables the use, not only of well-known algorithms and tools from the mathematical morphology, but also of any other segmentation method to segment DTI, since TMG computation transforms tensorial images in scalar ones.

  2. Preliminary clinical applications of DTI in human cervical spinal cord

    International Nuclear Information System (INIS)

    Song Ting; Mai Weiwen; Liang Biling; Shen Jun; Huang Suiqiao; Hu Chunhong

    2007-01-01

    Objective: To condcut preliminary study of the value of DTI(diffusion tensor imaging) in human cervical spinal cord. Methods: Twenty-one patients suffering from cervical spondylotic myelopathy and twenty volunteers without any clinical symptoms underwent routine MRI and DTI examination. DTI was performed in six non-collinear directions with single-shot fast spin echo echo, planar imaging sequence(b value = 400 s·mm -2 ). ADC(apparent diffusion coefficient) and FA(fractional anisotropy)values were measured by ROIs(regions of interest) in 4 different level segment spinal cord (C 2/3 , C 3/4 , C 4/5 , C 5/6 ) in normal volunteers, in lesions and normal segmental spinal cord in clinical cases respectively. DTI original images were automatically processed by using IDL (Version 5.6) soft- ware to produce color tensor images. SPSS11.0 software for windows was used for t-test and one-way ANOVA analysis. The difference was considered statistically significant if P 2/3 , C 3/4 , C 4/5 , C 5/6 , were analyzed and it was found that FA value between them had a significant difference by ANOVA, F=159.24, P 2/3 level. However, ADC value between 4 segments had no significant difference(F=2.191, P>0.05). (2)In patients of cervical spondylotic myelopathy, routine MRI T2WI showed abnormal signal in 9 cases, and showed no abnormal signal in 12 dases. In sixteen cases it was found that abnormal patchy green signal on colorized tensor maps appeared on the normal blue spinal cord. Also, in patients of cervical spondylotic myelopathy, there was significant difference in ADC and FA value between lesions and normal spinal cord (paired t test, for ADC, t=2.88, P 2/3 level segment spinal cord in normal volunteers (0.85 ± 0.03) is the highest among other segments. FA value decreases gradually along cervical spinal cord towards the caudal direction. However, the difference of ADC values amongst 4 segments is not significant. DTI colorized tensor maps can show more lesions than routine MRI

  3. A preliminary study of DTI Fingerprinting on stroke analysis.

    Science.gov (United States)

    Ma, Heather T; Ye, Chenfei; Wu, Jun; Yang, Pengfei; Chen, Xuhui; Yang, Zhengyi; Ma, Jingbo

    2014-01-01

    DTI (Diffusion Tensor Imaging) is a well-known MRI (Magnetic Resonance Imaging) technique which provides useful structural information about human brain. However, the quantitative measurement to physiological variation of subtypes of ischemic stroke is not available. An automatically quantitative method for DTI analysis will enhance the DTI application in clinics. In this study, we proposed a DTI Fingerprinting technology to quantitatively analyze white matter tissue, which was applied in stroke classification. The TBSS (Tract Based Spatial Statistics) method was employed to generate mask automatically. To evaluate the clustering performance of the automatic method, lesion ROI (Region of Interest) is manually drawn on the DWI images as a reference. The results from the DTI Fingerprinting were compared with those obtained from the reference ROIs. It indicates that the DTI Fingerprinting could identify different states of ischemic stroke and has promising potential to provide a more comprehensive measure of the DTI data. Further development should be carried out to improve DTI Fingerprinting technology in clinics.

  4. Role of DTI neuroimaging in diagnosis of vascular dementia

    International Nuclear Information System (INIS)

    Kozarova, G.; Georgieva- Penev, L.

    2013-01-01

    Full text: Introduction: Since its introduction more than two decades ago, Magnetic Resonance Imaging (MRI) has not only allowed for visualization of the macrostructure of the CNS, but also has been able to study dynamic processes which constitute the substrate of currently available MRI variants. Materials and methods: In this presentation, the potential role of MRI techniques, particularly DTI, for the study of the relationship between changes in the microstructural integrity of WM and cognitive impairment in the context of cerebrovascular disease and particularly the vascular dementia (VaD) are discussed. Results: While conventional Diffusion Weighted Imaging (DWI) permits a robust visualization of lesions just a few minutes after the onset of cerebral ischemia, Diffusion Tensor Imaging (DTI) measures the magnitude and direction of diffusion, leading to the characterization of cerebral white matter (WM) microstructural integrity of white matter fibers using quantitative fractionated anisotropy (DTI-FA) and tractography (DTI-TR). DTI-FA is an important technique in considering the large extension of white matter, and has been previously applied in clinical practice. DTI-TR can visualize the bundles interconnecting various regions whose interruption can cause a range of different disconnection syndromes. The method is not routinely used in clinical practice.In this presentation, the potential role of MRI techniques, particularly DTI, for the study of the relationship between changes in the microstructural integrity of WM and cognitive impairment in the context of cerebrovascular disease and particularly the vascular dementia (VaD) are discussed. Conclusion: Significant correlations between cognitive function and regional anisotropy values are an example of the potential efficacy of DTI for in vivo studies of brain connectivity in vascular neurodegenerative conditions

  5. Acute radial nerve entrapment at the spiral groove: detection by DTI-based neurography

    Energy Technology Data Exchange (ETDEWEB)

    Jengojan, Suren; Breitenseher, Julia; Weber, Michael; Prayer, Daniela; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuro- and Musculosceletal Radiology, Vienna (Austria); Kovar, Florian [Medical University of Vienna, Department of Trauma-Surgery, Vienna (Austria)

    2015-06-01

    This study evaluated the potential of three-tesla diffusion tensor imaging (DTI) and tractography to detect changes of the radial (RN) and median (MN) nerves during transient upper arm compression by a silicon ring tourniquet. Axial T2-weighted and DTI sequences (b = 700 s/mm{sup 2}, 16 gradient encoding directions) of 13 healthy volunteers were obtained. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the MN and RN were measured at the spiral groove and further visualized in 3D by deterministic tractography (thresholds: FA =.15, angle change = 27 ). Local/lesional RN FA values increased (p = 0.001) and ADC values decreased (p = 0.02) during a 20-min upper arm compression, whereas no significant FA (p = 0.49) or ADC (p = 0.73) changes of the MN were detected. There were no T2-w nerve signal changes or alterations of nerve trajectories in 3D. Acute nerve compression of the RN leads to changes of its three-tesla DTI metrics. Peripheral nerve DTI provides non-invasive insights into the ''selective'' vulnerability of the RN at the spiral groove. (orig.)

  6. Impact of Gradient Number and Voxel Size on Diffusion Tensor Imaging Tractography for Resective Brain Surgery

    NARCIS (Netherlands)

    Hoefnagels, Friso W. A.; de Witt Hamer, Philip C.; Pouwels, Petra J. W.; Barkhof, Frederik; Vandertop, W. Peter

    2017-01-01

    To explore quantitatively and qualitatively how the number of gradient directions (NGD) and spatial resolution (SR) affect diffusion tensor imaging (DTI) tractography in patients planned for brain tumor surgery, using routine clinical magnetic resonance imaging protocols. Of 67 patients with

  7. Impact of Gradient Number and Voxel Size on Diffusion Tensor Imaging Tractography for Resective Brain Surgery.

    Science.gov (United States)

    Hoefnagels, Friso W A; de Witt Hamer, Philip C; Pouwels, Petra J W; Barkhof, Frederik; Vandertop, W Peter

    2017-09-01

    To explore quantitatively and qualitatively how the number of gradient directions (NGD) and spatial resolution (SR) affect diffusion tensor imaging (DTI) tractography in patients planned for brain tumor surgery, using routine clinical magnetic resonance imaging protocols. Of 67 patients with intracerebral lesions who had 2 different DTI scans, 3 DTI series were reconstructed to compare the effects of NGD and SR. Tractographies for 4 clinically relevant tracts (corticospinal tract, superior longitudinal fasciculus, optic radiation, and inferior fronto-occipital fasciculus) were constructed with a probabilistic tracking algorithm and automated region of interest placement and compared for 3 quantitative measurements: tract volume, median fiber density, and mean fractional anisotropy, using linear mixed-effects models. The mean tractography volume and intersubject reliability were visually compared across scanning protocols, to assess the clinical relevance of the quantitative differences. Both NGD and SR significantly influenced tract volume, median fiber density, and mean fractional anisotropy, but not to the same extent. In particular, higher NGD increased tract volume and median fiber density. More importantly, these effects further increased when tracts were affected by disease. The effects were tract specific, but not dependent on threshold. The superior longitudinal fasciculus and inferior fronto-occipital fasciculus showed the most significant differences. Qualitative assessment showed larger tract volumes given a fixed confidence level, and better intersubject reliability for the higher NGD protocol. SR in the range we considered seemed less relevant than NGD. This study indicates that, under time constraints of clinical imaging, a higher number of diffusion gradients is more important than spatial resolution for superior DTI probabilistic tractography in patients undergoing brain tumor surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. DTI analysis methods : Voxel-based analysis

    NARCIS (Netherlands)

    Van Hecke, Wim; Leemans, Alexander; Emsell, Louise

    2016-01-01

    Voxel-based analysis (VBA) of diffusion tensor imaging (DTI) data permits the investigation of voxel-wise differences or changes in DTI metrics in every voxel of a brain dataset. It is applied primarily in the exploratory analysis of hypothesized group-level alterations in DTI parameters, as it does

  9. Microstructural integrity of white matter tracts amongst older fallers: A DTI study.

    Directory of Open Access Journals (Sweden)

    Yoke Queen Wong

    Full Text Available This study assesses the whole brain microstructural integrity of white matter tracts (WMT among older individuals with a history of falls compared to non-fallers.85 participants (43 fallers, 42 non-fallers were evaluated with conventional MRI and diffusion tensor imaging (DTI sequences of the brain. DTI metrics were obtained from selected WMT using tract-based spatial statistics (TBSS method. This was followed by binary logistic regression to investigate the clinical variables that could act as confounding elements on the outcomes. The TBSS analysis was then repeated, but this time including all significant predictor variables from the regression analysis as TBSS covariates.The mean diffusivity (MD and axial diffusivity (AD and to a lesser extent radial diffusivity (RD values of the projection fibers and commissural bundles were significantly different in fallers (p < 0.05 compared to non-fallers. However, the final logistic regression model obtained showed that only functional reach, white matter lesion volume, hypertension and orthostatic hypotension demonstrated statistical significant differences between fallers and non-fallers. No significant differences were found in the DTI metrics when taking into account age and the four variables as covariates in the repeated analysis.This DTI study of 85 subjects, do not support DTI metrics as a singular factor that contributes independently to the fall outcomes. Other clinical and imaging factors have to be taken into account.

  10. Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI.

    Science.gov (United States)

    Martin, Allan R; Aleksanderek, Izabela; Cohen-Adad, Julien; Tarmohamed, Zenovia; Tetreault, Lindsay; Smith, Nathaniel; Cadotte, David W; Crawley, Adrian; Ginsberg, Howard; Mikulis, David J; Fehlings, Michael G

    2016-01-01

    A recent meeting of international imaging experts sponsored by the International Spinal Research Trust (ISRT) and the Wings for Life Foundation identified 5 state-of-the-art MRI techniques with potential to transform the field of spinal cord imaging by elucidating elements of the microstructure and function: diffusion tensor imaging (DTI), magnetization transfer (MT), myelin water fraction (MWF), MR spectroscopy (MRS), and functional MRI (fMRI). However, the progress toward clinical translation of these techniques has not been established. A systematic review of the English literature was conducted using MEDLINE, MEDLINE-in-Progress, Embase, and Cochrane databases to identify all human studies that investigated utility, in terms of diagnosis, correlation with disability, and prediction of outcomes, of these promising techniques in pathologies affecting the spinal cord. Data regarding study design, subject characteristics, MRI methods, clinical measures of impairment, and analysis techniques were extracted and tabulated to identify trends and commonalities. The studies were assessed for risk of bias, and the overall quality of evidence was assessed for each specific finding using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. A total of 6597 unique citations were identified in the database search, and after full-text review of 274 articles, a total of 104 relevant studies were identified for final inclusion (97% from the initial database search). Among these, 69 studies utilized DTI and 25 used MT, with both techniques showing an increased number of publications in recent years. The review also identified 1 MWF study, 11 MRS studies, and 8 fMRI studies. Most of the studies were exploratory in nature, lacking a priori hypotheses and showing a high (72%) or moderately high (20%) risk of bias, due to issues with study design, acquisition techniques, and analysis methods. The acquisitions for each technique varied widely across

  11. DTI measurements for Alzheimer’s classification

    Science.gov (United States)

    Maggipinto, Tommaso; Bellotti, Roberto; Amoroso, Nicola; Diacono, Domenico; Donvito, Giacinto; Lella, Eufemia; Monaco, Alfonso; Antonella Scelsi, Marzia; Tangaro, Sabina; Disease Neuroimaging Initiative, Alzheimer's.

    2017-03-01

    Diffusion tensor imaging (DTI) is a promising imaging technique that provides insight into white matter microstructure integrity and it has greatly helped identifying white matter regions affected by Alzheimer’s disease (AD) in its early stages. DTI can therefore be a valuable source of information when designing machine-learning strategies to discriminate between healthy control (HC) subjects, AD patients and subjects with mild cognitive impairment (MCI). Nonetheless, several studies have reported so far conflicting results, especially because of the adoption of biased feature selection strategies. In this paper we firstly analyzed DTI scans of 150 subjects from the Alzheimer’s disease neuroimaging initiative (ADNI) database. We measured a significant effect of the feature selection bias on the classification performance (p-value  informative content provided by DTI measurements for AD classification. Classification performances and biological insight, concerning brain regions related to the disease, provided by cross-validation analysis were both confirmed on the independent test.

  12. Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI

    Directory of Open Access Journals (Sweden)

    Allan R. Martin

    2016-01-01

    Conclusions: State-of-the-art spinal cord MRI techniques are emerging with great potential to improve the diagnosis and management of various spinal pathologies, but the current body of evidence has only showed limited clinical utility to date. Among these imaging tools DTI is the most mature, but further work is necessary to standardize and validate its use before it will be adopted in the clinical realm. Large, well-designed studies with a priori hypotheses, standardized acquisition methods, detailed clinical data collection, and robust automated analysis techniques are needed to fully demonstrate the potential of these rapidly evolving techniques.

  13. Illustrative uncertainty visualization of DTI fiber pathways

    NARCIS (Netherlands)

    Brecheisen, R.; Platel, B.; Haar Romeny, B.M. Ter; Vilanova, A.

    2013-01-01

    Diffusion Tensor Imaging (DTI) and fiber tracking provide unique insight into the 3D structure of fibrous tissues in the brain. However, the output of fiber tracking contains a significant amount of uncertainty accumulated in the various steps of the processing pipeline. Existing DTI visualization

  14. DTI fiber tractography of cerebro-cerebellar pathways and clinical evaluation of ataxia in childhood posterior fossa tumor survivors.

    Science.gov (United States)

    Oh, Myung Eun; Driever, Pablo Hernáiz; Khajuria, Rajiv K; Rueckriegel, Stefan Mark; Koustenis, Elisabeth; Bruhn, Harald; Thomale, Ulrich-Wilhelm

    2017-01-01

    Pediatric posterior fossa (PF) tumor survivors experience long-term motor deficits. Specific cerebrocerebellar connections may be involved in incidence and severity of motor dysfunction. We examined the relationship between long-term ataxia as well as fine motor function and alteration of differential cerebellar efferent and afferent pathways using diffusion tensor imaging (DTI) and tractography. DTI-based tractography was performed in 19 patients (10 pilocytic astrocytoma (PA) and 9 medulloblastoma patients (MB)) and 20 healthy peers. Efferent Cerebello-Thalamo-Cerebral (CTC) and afferent Cerebro-Ponto-Cerebellar (CPC) tracts were reconstructed and analyzed concerning fractional anisotropy (FA) and volumetric measurements. Clinical outcome was assessed with the International Cooperative Ataxia Rating Scale (ICARS). Kinematic parameters of fine motor function (speed, automation, variability, and pressure) were obtained by employing a digitizing graphic tablet. ICARS scores were significantly higher in MB patients than in PA patients. Poorer ICARS scores and impaired fine motor function correlated significantly with volume loss of CTC pathway in MB patients, but not in PA patients. Patients with pediatric post-operative cerebellar mutism syndrome showed higher loss of CTC pathway volume and were more atactic. CPC pathway volume was significantly reduced in PA patients, but not in MB patients. Neither relationship was observed between the CPC pathway and ICARS or fine motor function. There was no group difference of FA values between the patients and healthy peers. Reduced CTC pathway volumes in our cohorts were associated with severity of long-term ataxia and impaired fine motor function in survivors of MBs. We suggest that the CTC pathway seems to play a role in extent of ataxia and fine motor dysfunction after childhood cerebellar tumor treatment. DTI may be a useful tool to identify relevant structures of the CTC pathway and possibly avoid surgically induced long

  15. Evaluation of skeletal muscle DTI in patients with duchenne muscular dystrophy.

    Science.gov (United States)

    Hooijmans, M T; Damon, B M; Froeling, M; Versluis, M J; Burakiewicz, J; Verschuuren, J J G M; Niks, E H; Webb, A G; Kan, H E

    2015-11-01

    Diffusion tensor imaging (DTI) is a popular method to assess differences in fiber organization in diseased and healthy muscle tissue. Previous work has shown that muscle DTI measurements depend on signal-to-noise ratio (SNR), %fat, and tissue T2. The goal of this study was to evaluate the potential biasing effects of these factors on skeletal muscle DTI data in patients with Duchenne Muscular Dystrophy (DMD). MR images were obtained of the right lower leg of 21 DMD patients and 12 healthy controls on a Philips 3T system. DTI measurements were combined with quantitative in-vivo measures of mean water T2, %fat and SNR to evaluate their effect on DTI parameter estimation. All outcome measures were determined within ROIs drawn for six lower leg muscles. Between group analysis, using all ROIs, revealed a significantly elevated FA in the GCL, SOL and PER muscles (pDTI parameter estimation. These findings suggest that measuring mean water T2, %fat and SNR is essential to ascribe changes in DTI measures to intrinsic diffusion changes or to confounding influences. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Language pathway tracking: comparing nTMS-based DTI fiber tracking with a cubic ROIs-based protocol.

    Science.gov (United States)

    Negwer, Chiara; Sollmann, Nico; Ille, Sebastian; Hauck, Theresa; Maurer, Stefanie; Kirschke, Jan S; Ringel, Florian; Meyer, Bernhard; Krieg, Sandro M

    2017-03-01

    OBJECTIVE Diffusion tensor imaging (DTI) fiber tracking (FT) has been widely used in glioma surgery in recent years. It can provide helpful information about subcortical structures, especially in patients with eloquent space-occupying lesions. This study compared the newly developed navigated transcranial magnetic stimulation (nTMS)-based DTI FT of language pathways with the most reproducible protocol for language pathway tractography, using cubic regions of interest (ROIs) for the arcuate fascicle. METHODS Thirty-seven patients with left-sided perisylvian lesions underwent language mapping by repetitive nTMS. DTI FT was performed using the cubic ROIs-based protocol and the authors' nTMS-based DTI FT approach. The same minimal fiber length and fractional anisotropy were chosen (50 mm and 0.2, respectively). Both protocols were performed with standard clinical tractography software. RESULTS Both methods visualized language-related fiber tracts (i.e., corticonuclear tract, arcuate fascicle, uncinate fascicle, superior longitudinal fascicle, inferior longitudinal fascicle, arcuate fibers, commissural fibers, corticothalamic fibers, and frontooccipital fascicle) in all 37 patients. Using the cubic ROIs-based protocol, 39.9% of these language-related fiber tracts were detected in the examined patients, as opposed to 76.0% when performing nTMS-based DTI FT. For specifically tracking the arcuate fascicle, however, the cubic ROIs-based approach showed better results (97.3% vs 75.7% with nTMS-based DTI FT). CONCLUSIONS The cubic ROIs-based protocol was designed for arcuate fascicle tractography, and this study shows that it is still useful for this intention. However, superior results were obtained using the nTMS-based DTI FT for visualization of other language-related fiber tracts.

  17. Direction-controlled DTI interpolation

    NARCIS (Netherlands)

    Florack, L.M.J.; Dela Haije, T.C.J.; Fuster, A.; Hotz, I.; Schultz, T.

    2015-01-01

    Diffusion Tensor Imaging (DTI) is a popular model for representing diffusion weighted magnetic resonance images due to its simplicity and the fact that it strikes a good balance between signal fit and robustness. Nevertheless, problematic issues remain. One of these concerns the problem of

  18. Revised DTI Guidelines for Petroleum Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.; Philip, L.N.

    1997-07-01

    The DTI's guidelines on petroleum measurement have been extensively revised and enlarged. The new guidelines cover a much wider scope of measurement situations than before. Included in the new issue is guidance on allocation measurement, well testing, multiphase flow measurement, new technology acceptance procedures and operating procedures for different types of measurement systems. Significant changes have taken place in recent years both in the way the oil and gas industry conducts its business and in the fiscal regime operated by the UK government. New developments in flow measurement have progressed to such an extent that they have now been adopted by the industry or are close to being adopted as beneficial methods of the measurement of hydrocarbons in whatever form they present themselves for measurement. The rapid pace of development has left the standards-making bodies behind and in some cases there is insufficient quality data to enable the standards makers to produce guidance of the generic type appropriate for national or international standards. The case-by-case approach of the DTI in approving methods of measurement lends itself better to consideration of new technology where there may be no existing standards. These, amongst other considerations, make it appropriate for the DTI to extend the scope of its guidance into these new areas. The policy developments behind the changes in the new guidelines are not static and this new document has been produced in response to an evolutionary process which is still continuing but it is right to collate and make defining statements from time to time to put on record the current status of measurement requirements for the purpose of attaining DTI approval. (author)

  19. Medio-dorsal thalamus and confabulations: Evidence from a clinical case and combined MRI/DTI study

    Directory of Open Access Journals (Sweden)

    Valeria Onofrj

    2016-01-01

    Full Text Available The Medio-Dorsal Nuclei (MDN including the thalamic magnocellular and parvocellular thalamic regions has been implicated in verbal memory function. In a 77 year old lady, with a prior history of a clinically silent infarct of the left MDN, we observed the acute onset of spontaneous confabulations when an isolated new infarct occurred in the right MDN. The patient and five age-matched healthy subjects underwent Magnetic Resonance Imaging (MRI and Diffusion Tensor Imaging (DTI. The thalamic lesions were localized by overlapping Morel Thalamic Atlas with structural MRI data. DTI was used to assess: i white matter alterations (Fractional Anisotropy, FA within fibers connecting the ischemic areas to cortex; ii the micro-structural damage (Mean Diffusivity within the thalamic sub-regions defined by their structural connectivity to the Anterior Cingulate Cortex (ACC and to the temporal lobes. These target regions were chosen because their damage is considered associated with the appearance of confabulations. Thalamic lesions were localized within the parvocellular regions of the right and left MDNs. The structural connectivity study showed that the fiber tracts, connecting the bilaterally damaged thalamic regions with the frontal cortex, corresponded to the anterior thalamic radiations (ATR. FA within these tracts was significantly lower in the patient as compared to controls. Mean diffusivity within the MDNs projecting to Broadman area (BA 24, BA25 and BA32 of ACC was significantly higher in the patient than in control group. Mean diffusivity values within the MDN projecting to temporal lobes in contrast were not different between patient and controls. Our findings suggest the involvement of bilateral MDNs projections to ACC in the genesis of confabulations and help provide clarity to the longstanding debate on the origin of confabulations.

  20. DTI study of Children with Congenital Hydrocephalus: 1 Year Post-Surgical Outcomes

    Science.gov (United States)

    Mangano, Francesco T.; Altaye, Mekibib; McKinstry, Robert C.; Shimony, Joshua S.; Powell, Stephanie K.; Phillips, Jannel M.; Barnard, Holly; Limbrick, David D.; Holland, Scott K.; Jones, Blaise V.; Dodd, Jonathon; Simpson, Sarah; Deanna, Mercer; Rajagopal, Akila; Bidwell, Sarah; Yuan, Weihong

    2016-01-01

    Object To investigate white matter structural abnormalities using diffusion tensor imaging (DTI) in children with hydrocephalus before CSF diversionary surgery (including ventriculoperitoneal shunting and endoscopic third ventriculoscopy) and the course of recovery post-surgery in association with neuropsychological and behavioral outcome. Methods This was a prospective study that included 54 children with congenital hydrocephalus (21F/33M; age range: 0.03–194.5 months) who underwent surgery and 64 normal controls (30F/34M, age range: 0.30–197.75 months). DTI and neurodevelopmental outcome data were collected once in the control group and at pre-surgery, 3-month, and 12-month post-surgery in the patients. DTI measures, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) values were extracted from the genu of corpus callosum (gCC) and the posterior limb of internal capsule (PLIC). Group analysis was performed first cross-sectionally to quantify DTI abnormalities at three time points by comparing the controls and the patients group at the three time points separately. Longitudinal comparisons were conducted pairwise between different time points in patients whose data were acquired at multiple time points. Neurodevelopmental data were collected and analyzed using the Adaptive Behavior Assessment System, Second Edition (ABAS-II) and the Bayley Scales of Infant Development, Third Edition (Bayley-III). Correlation analyses were performed between DTI and behavioral outcomes. Results Significant DTI abnormalities were found in both the gCC (lower FA and higher MD, AD, and RD) and the PLIC (higher FA, lower AD and RD) at pre-surgery. The DTI measures in the gCC remained mostly abnormal at 3-month and 12-month post-surgery. The DTI abnormalities in the PLIC were significant in FA and AD at 3-month post-surgery but did nor persist when tested at 12-month post-surgery. Significant longitudinal DTI changes in the

  1. Diffusion tensor imaging (DTI) findings in adult civilian, military, and sport-related mild traumatic brain injury (mTBI): a systematic critical review.

    Science.gov (United States)

    Asken, Breton Michael; DeKosky, Steven T; Clugston, James R; Jaffee, Michael S; Bauer, Russell M

    2018-04-01

    This review seeks to summarize diffusion tensor imaging (DTI) studies that have evaluated structural changes attributed to the mechanisms of mild traumatic brain injury (mTBI) in adult civilian, military, and athlete populations. Articles from 2002 to 2016 were retrieved from PubMed/MEDLINE, EBSCOhost, and Google Scholar, using a Boolean search string containing the following terms: "diffusion tensor imaging", "diffusion imaging", "DTI", "white matter", "concussion", "mild traumatic brain injury", "mTBI", "traumatic brain injury", and "TBI". We added studies not identified by this method that were found via manually-searched reference lists. We identified 86 eligible studies from English-language journals using, adult, human samples. Studies were evaluated based on duration between injury and DTI assessment, categorized as acute, subacute/chronic, remote mTBI, and repetitive brain trauma considerations. Since changes in brain structure after mTBI can also be affected by other co-occurring medical and demographic factors, we also briefly review DTI studies that have addressed socioeconomic status factors (SES), major depressive disorder (MDD), and attention-deficit hyperactivity disorder (ADHD). The review describes population-specific risks and the complications of clinical versus pathophysiological outcomes of mTBI. We had anticipated that the distinct population groups (civilian, military, and athlete) would require separate consideration, and various aspects of the study characteristics supported this. In general, study results suggested widespread but inconsistent differences in white matter diffusion metrics (primarily fractional anisotropy [FA], mean diffusivity [MD], radial diffusivity [RD], and axial diffusivity [AD]) following mTBI/concussion. Inspection of study designs and results revealed potential explanations for discrepant DTI findings, such as control group variability, analytic techniques, the manner in which regional differences were reported, and

  2. Histological validation of high-resolution DTI in human post mortem tissue

    NARCIS (Netherlands)

    Seehaus, A.; Roebroeck, A.; Bastiani, M.; Fonseca, L.; Bratzke, H.; Lori, N.; Vilanova, A.; Goebel, R.; Galuske, R.

    2015-01-01

    Diffusion tensor imaging (DTI) is amongst the simplest mathematical models available for diffusion magnetic resonance imaging, yet still by far the most used one. Despite the success of DTI as an imaging tool for white matter fibers, its anatomical underpinnings on a microstructural basis remain

  3. Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, Maria Isabel; Nguyen, Duy; Delavelle, Jacqueline [Geneva University Hospital, Department of Neuroradiology, DISIM, Geneve 14 (Switzerland); Viallon, Magalie [Geneva University Hospital and University of Geneva, Radiology, Geneva (Switzerland); Becker, Minerva [Geneva University Hospital and University of Geneva, Unit of Head and Neck Radiology, Geneva (Switzerland)

    2010-03-15

    The objective of this study was to assess the feasibility and potential clinical applications of diffusion tensor imaging (DTI) and tractography in the normal and pathologic brachial plexus prospectively. Six asymptomatic volunteers and 12 patients with symptoms related to the brachial plexus underwent DTI on a 1.5T system in addition to the routine anatomic plexus imaging protocol. Maps of the apparent diffusion coefficient (ADC) and of fractional anisotropy (FA), as well as tractography of the brachial plexus were obtained. Images were evaluated by two experienced neuroradiologists in a prospective fashion. Three patients underwent surgery, and nine patients underwent conservative medical treatment. Reconstructed DTI (17/18) were of good quality (one case could not be reconstructed due to artifacts). In all volunteers and in 11 patients, the roots and the trunks were clearly delineated with tractography. Mean FA and mean ADC values were as follows: 0.30{+-}0.079 and 1.70{+-}0.35 mm{sup 2}/s in normal fibers, 0.22{+-}0.04 and 1.49{+-}0.49 mm{sup 2}/s in benign neurogenic tumors, and 0.24{+-}0.08 and 1.51{+-}0.52 mm{sup 2}/s in malignant tumors, respectively. Although there was no statistically significant difference in FA and ADC values of normal fibers and fibers at the level of pathology, tractography revealed major differences regarding fiber architecture. In benign neurogenic tumors (n=4), tractography revealed fiber displacement alone (n=2) or fiber displacement and encasement by the tumor (n=2), whereas in the malignant tumors, either fiber disruption/destruction with complete disorganization (n=6) or fiber displacement (n=1) were seen. In patients with fiber displacement alone, surgery confirmed the tractography findings, and excision was successful without sequelae. Our preliminary data suggest that DTI with tractography is feasible in a clinical routine setting. DTI may demonstrate normal tracts, tract displacement, deformation, infiltration, disruption

  4. Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions

    International Nuclear Information System (INIS)

    Vargas, Maria Isabel; Nguyen, Duy; Delavelle, Jacqueline; Viallon, Magalie; Becker, Minerva

    2010-01-01

    The objective of this study was to assess the feasibility and potential clinical applications of diffusion tensor imaging (DTI) and tractography in the normal and pathologic brachial plexus prospectively. Six asymptomatic volunteers and 12 patients with symptoms related to the brachial plexus underwent DTI on a 1.5T system in addition to the routine anatomic plexus imaging protocol. Maps of the apparent diffusion coefficient (ADC) and of fractional anisotropy (FA), as well as tractography of the brachial plexus were obtained. Images were evaluated by two experienced neuroradiologists in a prospective fashion. Three patients underwent surgery, and nine patients underwent conservative medical treatment. Reconstructed DTI (17/18) were of good quality (one case could not be reconstructed due to artifacts). In all volunteers and in 11 patients, the roots and the trunks were clearly delineated with tractography. Mean FA and mean ADC values were as follows: 0.30±0.079 and 1.70±0.35 mm 2 /s in normal fibers, 0.22±0.04 and 1.49±0.49 mm 2 /s in benign neurogenic tumors, and 0.24±0.08 and 1.51±0.52 mm 2 /s in malignant tumors, respectively. Although there was no statistically significant difference in FA and ADC values of normal fibers and fibers at the level of pathology, tractography revealed major differences regarding fiber architecture. In benign neurogenic tumors (n=4), tractography revealed fiber displacement alone (n=2) or fiber displacement and encasement by the tumor (n=2), whereas in the malignant tumors, either fiber disruption/destruction with complete disorganization (n=6) or fiber displacement (n=1) were seen. In patients with fiber displacement alone, surgery confirmed the tractography findings, and excision was successful without sequelae. Our preliminary data suggest that DTI with tractography is feasible in a clinical routine setting. DTI may demonstrate normal tracts, tract displacement, deformation, infiltration, disruption, and disorganization of

  5. Identifying the white matter impairments among ART-naive HIV patients: a multivariate pattern analysis of DTI data

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Zhenchao [Shandong University, School of Mechanical, Electrical and Information Engineering, Weihai, Shandong Province (China); Institute of Automation, CAS Key Laboratory of Molecular Imaging, Beijing (China); Liu, Zhenyu; Yang, Xin; Wang, Shuo; Yu, Dongdong [Institute of Automation, CAS Key Laboratory of Molecular Imaging, Beijing (China); Li, Ruili; Li, Hongjun [Beijing YouAn Hospital, Capital Medical University, Department of Radiology, Beijing (China); Cui, Xingwei [Zhengzhou University, Cooperative Innovation Center of Internet Healthcare, Zhengzhou (China); Dong, Enqing [Shandong University, School of Mechanical, Electrical and Information Engineering, Weihai, Shandong Province (China); Tian, Jie [Institute of Automation, CAS Key Laboratory of Molecular Imaging, Beijing (China); University of Chinese Academy of Sciences, Beijing (China)

    2017-10-15

    To identify the white matter (WM) impairments of the antiretroviral therapy (ART)-naive HIV patients by conducting a multivariate pattern analysis (MVPA) of Diffusion Tensor Imaging (DTI) data We enrolled 33 ART-naive HIV patients and 32 Normal controls in the current study. Firstly, the DTI metrics in whole brain WM tracts were extracted for each subject and feed into the Least Absolute Shrinkage and Selection Operators procedure (LASSO)-Logistic regression model to identify the impaired WM tracts. Then, Support Vector Machines (SVM) model was constructed based on the DTI metrics in the impaired WM tracts to make HIV-control group classification. Pearson correlations between the WM impairments and HIV clinical statics were also investigated. Extensive HIV-related impairments were observed in the WM tracts associated with motor function, the corpus callosum (CC) and the frontal WM. With leave-one-out cross validation, accuracy of 83.08% (P=0.002) and the area under the Receiver Operating Characteristic curve of 0.9110 were obtained in the SVM classification model. The impairments of the CC were significantly correlated with the HIV clinic statics. The MVPA was sensitive to detect the HIV-related WM changes. Our findings indicated that the MVPA had considerable potential in exploring the HIV-related WM impairments. (orig.)

  6. Identifying the white matter impairments among ART-naive HIV patients: a multivariate pattern analysis of DTI data

    International Nuclear Information System (INIS)

    Tang, Zhenchao; Liu, Zhenyu; Yang, Xin; Wang, Shuo; Yu, Dongdong; Li, Ruili; Li, Hongjun; Cui, Xingwei; Dong, Enqing; Tian, Jie

    2017-01-01

    To identify the white matter (WM) impairments of the antiretroviral therapy (ART)-naive HIV patients by conducting a multivariate pattern analysis (MVPA) of Diffusion Tensor Imaging (DTI) data We enrolled 33 ART-naive HIV patients and 32 Normal controls in the current study. Firstly, the DTI metrics in whole brain WM tracts were extracted for each subject and feed into the Least Absolute Shrinkage and Selection Operators procedure (LASSO)-Logistic regression model to identify the impaired WM tracts. Then, Support Vector Machines (SVM) model was constructed based on the DTI metrics in the impaired WM tracts to make HIV-control group classification. Pearson correlations between the WM impairments and HIV clinical statics were also investigated. Extensive HIV-related impairments were observed in the WM tracts associated with motor function, the corpus callosum (CC) and the frontal WM. With leave-one-out cross validation, accuracy of 83.08% (P=0.002) and the area under the Receiver Operating Characteristic curve of 0.9110 were obtained in the SVM classification model. The impairments of the CC were significantly correlated with the HIV clinic statics. The MVPA was sensitive to detect the HIV-related WM changes. Our findings indicated that the MVPA had considerable potential in exploring the HIV-related WM impairments. (orig.)

  7. Evaluation of skeletal muscle DTI in patients with duchenne muscular dystrophy

    NARCIS (Netherlands)

    Hooijmans, M. T.; Damon, B. M.; Froeling, M.; Versluis, M. J.; Burakiewicz, J.; Verschuuren, J. J G M; Niks, E. H.; Webb, A. G.; Kan, H. E.

    2015-01-01

    Diffusion tensor imaging (DTI) is a popular method to assess differences in fiber organization in diseased and healthy muscle tissue. Previous work has shown that muscle DTI measurements depend on signal-to-noise ratio (SNR), %fat, and tissue T2. The goal of this study was to evaluate the potential

  8. Population-averaged macaque brain atlas with high-resolution ex vivo DTI integrated into in vivo space.

    Science.gov (United States)

    Feng, Lei; Jeon, Tina; Yu, Qiaowen; Ouyang, Minhui; Peng, Qinmu; Mishra, Virendra; Pletikos, Mihovil; Sestan, Nenad; Miller, Michael I; Mori, Susumu; Hsiao, Steven; Liu, Shuwei; Huang, Hao

    2017-12-01

    Animal models of the rhesus macaque (Macaca mulatta), the most widely used nonhuman primate, have been irreplaceable in neurobiological studies. However, a population-averaged macaque brain diffusion tensor imaging (DTI) atlas, including comprehensive gray and white matter labeling as well as bony and facial landmarks guiding invasive experimental procedures, is not available. The macaque white matter tract pathways and microstructures have been rarely recorded. Here, we established a population-averaged macaque brain atlas with high-resolution ex vivo DTI integrated into in vivo space incorporating bony and facial landmarks, and delineated microstructures and three-dimensional pathways of major white matter tracts in vivo MRI/DTI and ex vivo (postmortem) DTI of ten rhesus macaque brains were acquired. Single-subject macaque brain DTI template was obtained by transforming the postmortem high-resolution DTI data into in vivo space. Ex vivo DTI of ten macaque brains was then averaged in the in vivo single-subject template space to generate population-averaged macaque brain DTI atlas. The white matter tracts were traced with DTI-based tractography. One hundred and eighteen neural structures including all cortical gyri, white matter tracts and subcortical nuclei, were labeled manually on population-averaged DTI-derived maps. The in vivo microstructural metrics of fractional anisotropy, axial, radial and mean diffusivity of the traced white matter tracts were measured. Population-averaged digital atlas integrated into in vivo space can be used to label the experimental macaque brain automatically. Bony and facial landmarks will be available for guiding invasive procedures. The DTI metric measurements offer unique insights into heterogeneous microstructural profiles of different white matter tracts.

  9. The role of DTI in early detection of cervical spondylotic myelopathy: a preliminary study with 3-T MRI

    International Nuclear Information System (INIS)

    Kara, Batuhan; Celik, Azim; Karadereler, Selhan; Ulusoy, Levent; Ganiyusufoglu, Kursat; Onat, Levent; Mutlu, Ayhan; Sirvanci, Mustafa; Ornek, Ibrahim; Hamzaoglu, Azmi

    2011-01-01

    The radiological diagnosis of cervical spondylotic myelopathy (CSM) has to be made as soon as possible, since surgery performed in earlier stages during the course of CSM was reported to be more successful when compared with later stages. We hypothesized that diffusion tensor imaging (DTI) may detect CSM in earlier stages, before the appearance of signal increase in T2-weighted sequences. A total of 16 patients with neurological signs and symptoms of CSM but without hyperintensity in spinal cord on T2-weighted sequences enrolled in the study. The magnetic resonance (MR) examinations were performed on a 3-T MR imaging system. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps were generated on axial plane. The ADC and FA measurements in each individual were made at the level of most severe cervical canal stenosis and at a nonstenotic level. Student's t test was used to compare FA and ADC values of the spinal cord in stenotic and nonstenotic segments. We also investigated if there was a correlation between DTI parametrics and duration of clinical symptoms by using Pearson correlation analysis. All patients showed changes in DTI parametrics at stenotic segments. While FA values of the spinal cord at the stenotic level showed a statistically significant reduction, there was a statistically significant increase in the measured ADC values (p < 0.001). There was no statistical correlation between the duration of symptoms and DTI parametrics. Our preliminary findings indicate that DTI may show abnormalities in the spinal cord before the development of T2 hyperintensity on conventional sequences in patients with CSM. (orig.)

  10. TU-CD-BRB-05: Radiation Damage Signature of White Matter Fiber Bundles Using Diffusion Tensor Imaging (DTI)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, T; Chapman, C; Lawrence, T; Cao, Y [University of Michigan, Ann Arbor, MI (United States); Tsien, C [Washington University at St. Louis, St. Louis, MO (United States)

    2015-06-15

    Purpose: To develop an automated and scalable approach and identify temporal, spatial and dosimetric patterns of radiation damage of white matter (WM) fibers following partial brain irradiation. Methods: An automated and scalable approach was developed to extract DTI features of 22 major WM fibers from 33 patients with low-grade/benign tumors treated by radiation therapy (RT). DTI scans of the patients were performed pre-RT, 3- and 6-week during RT, and 1, 6 and 18 months after RT. The automated tractography analysis was applied to 198 datasets as: (1) intra-subject registration of longitudinal DTI, (2) spatial normalization of individual-patient DTI to the Johns Hopkins WM Atlas, (3) automatic fiber tracking regulated by the WM Atlas, and (4) segmentation of WM into 22 major tract profiles. Longitudinal percentage changes in fractional anisotropy (FA), and mean, axial and radial diffusivity (MD/AD/RD) of each tract from pre-RT were quantified and correlated to 95%, 90% and 80% percentiles of doses and mean doses received by the tract. Heatmaps were used to identify clusters of significant correlation and reveal temporal, spatial and dosimetric signatures of WM damage. A multivariate linear regression was further carried out to determine influence of clinical factors. Results: Of 22 tracts, AD/MD changes in 12 tracts had significant correlation with doses, especially at 6 and 18 months post-RT, indicating progressive radiation damage after RT. Most interestingly, the DTI-index changes in the elongated tracts were associated with received maximum doses, suggesting a serial-structure behavior; while short association fibers were affected by mean doses, indicating a parallel-structure response. Conclusion: Using an automated DTI-tractography analysis of whole brain WM fibers, we reveal complex radiation damage patterns of WM fibers. Damage in WM fibers that play an important role in the neural network could be associated with late neurocognitive function declines

  11. DTI Analysis of Presbycusis Using Voxel-Based Analysis.

    Science.gov (United States)

    Ma, W; Li, M; Gao, F; Zhang, X; Shi, L; Yu, L; Zhao, B; Chen, W; Wang, G; Wang, X

    2016-07-14

    Presbycusis is the most common sensory deficit in the aging population. A recent study reported using a DTI-based tractography technique to identify a lack of integrity in a portion of the auditory pathway in patients with presbycusis. The aim of our study was to investigate the white matter pathology of patients with presbycusis by using a voxel-based analysis that is highly sensitive to local intensity changes in DTI data. Fifteen patients with presbycusis and 14 age- and sex-matched healthy controls were scanned on a 3T scanner. Fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity were obtained from the DTI data. Intergroup statistics were implemented on these measurements, which were transformed to Montreal Neurological Institute coordinates by using a nonrigid image registration method called large deformation diffeomorphic metric mapping. Increased axial diffusivity, radial diffusivity, and mean diffusivity and decreased fractional anisotropy were found near the right-side hearing-related areas in patients with presbycusis. Increased radial diffusivity and mean diffusivity were also found near a language-related area (Broca area) in patients with presbycusis. Our findings could be important for exploring reliable imaging evidence of presbycusis and could complement an ROI-based approach. © 2016 American Society of Neuroradiology.

  12. The role of DTI in early detection of cervical spondylotic myelopathy: a preliminary study with 3-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kara, Batuhan [Bakirkoey Dr. Sadi Konuk Teaching Hospital, Department of Radiology, Istanbul (Turkey); Celik, Azim [General Electric Healthcare, Istanbul (Turkey); Karadereler, Selhan [Florence Nightingale Hospital, Department of Neurosurgery, Istanbul (Turkey); Ulusoy, Levent; Ganiyusufoglu, Kursat; Onat, Levent; Mutlu, Ayhan; Sirvanci, Mustafa [Florence Nightingale Hospital, Department of Radiology, Istanbul (Turkey); Ornek, Ibrahim [Florence Nightingale Hospital, Department of Neurology, Istanbul (Turkey); Hamzaoglu, Azmi [Florence Nightingale Hospital, Department of Orthopedic Surgery, Istanbul (Turkey)

    2011-08-15

    The radiological diagnosis of cervical spondylotic myelopathy (CSM) has to be made as soon as possible, since surgery performed in earlier stages during the course of CSM was reported to be more successful when compared with later stages. We hypothesized that diffusion tensor imaging (DTI) may detect CSM in earlier stages, before the appearance of signal increase in T2-weighted sequences. A total of 16 patients with neurological signs and symptoms of CSM but without hyperintensity in spinal cord on T2-weighted sequences enrolled in the study. The magnetic resonance (MR) examinations were performed on a 3-T MR imaging system. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps were generated on axial plane. The ADC and FA measurements in each individual were made at the level of most severe cervical canal stenosis and at a nonstenotic level. Student's t test was used to compare FA and ADC values of the spinal cord in stenotic and nonstenotic segments. We also investigated if there was a correlation between DTI parametrics and duration of clinical symptoms by using Pearson correlation analysis. All patients showed changes in DTI parametrics at stenotic segments. While FA values of the spinal cord at the stenotic level showed a statistically significant reduction, there was a statistically significant increase in the measured ADC values (p < 0.001). There was no statistical correlation between the duration of symptoms and DTI parametrics. Our preliminary findings indicate that DTI may show abnormalities in the spinal cord before the development of T2 hyperintensity on conventional sequences in patients with CSM. (orig.)

  13. A pilot DTI analysis in patients with recent onset post-traumatic stress disorder

    Science.gov (United States)

    Liu, Yang; Li, Liang; Li, Baojuan; Zhang, Xi; Lu, Hongbing

    2016-03-01

    To explore the alteration in white matter between survivors with recent onset post-traumatic stress disorder (PTSD) and without PTSD, who survived from the same coal mine flood disaster, the diffusion tensor imaging (DTI) sequences were analyzed using DTI studio and statistical parametric mapping (SPM) packages in this paper. From DTI sequence, the fractional anisotropy (FA) value describes the degree of anisotropy of a diffusion process, while the apparent diffusion coefficient (ADC) value reflects the magnitude of water diffusion. The DTI analyses between PTSD and non-PTSD indicate lower FA values in the right caudate nucleus, right middle temporal gyrus, right fusiform gyrus, and right superior temporal gyrus, and higher ADC values in the right superior temporal gyrus and right corpus callosum of the subjects with PTSD. These results are partly in line with our previous volume and cortical thickness analyses, indicating the importance of multi-modality analysis for PTSD.

  14. Tracking the Re-organization of Motor Functions After Disconnective Surgery: A Longitudinal fMRI and DTI Study

    Directory of Open Access Journals (Sweden)

    Cristina Rosazza

    2018-06-01

    Full Text Available Objective: Mechanisms of motor plasticity are critical to maintain motor functions after cerebral damage. This study explores the mechanisms of motor reorganization occurring before and after surgery in four patients with drug-refractory epilepsy candidate to disconnective surgery.Methods: We studied four patients with early damage, who underwent tailored hemispheric surgery in adulthood, removing the cortical motor areas and disconnecting the corticospinal tract (CST from the affected hemisphere. Motor functions were assessed clinically, with functional MRI (fMRI tasks of arm and leg movement and Diffusion Tensor Imaging (DTI before and after surgery with assessments of up to 3 years. Quantifications of fMRI motor activations and DTI fractional anisotropy (FA color maps were performed to assess the lateralization of motor network. We hypothesized that lateralization of motor circuits assessed preoperatively with fMRI and DTI was useful to evaluate the motor outcome in these patients.Results: In two cases preoperative DTI-tractography did not reconstruct the CST, and FA-maps were strongly asymmetric. In the other two cases, the affected CST appeared reduced compared to the contralateral one, with modest asymmetry in the FA-maps. fMRI showed different degrees of lateralization of the motor network and the SMA of the intact hemisphere was mostly engaged in all cases. After surgery, patients with a strongly lateralized motor network showed a stable performance. By contrast, a patient with a more bilateral pattern showed worsening of the upper limb function. For all cases, fMRI activations shifted to the intact hemisphere. Structural alterations of motor circuits, observed with FA values, continued beyond 1 year after surgery.Conclusion: In our case series fMRI and DTI could track the longitudinal reorganization of motor functions. In these four patients the more the paretic limbs recruited the intact hemisphere in primary motor and associative

  15. Tracking the Re-organization of Motor Functions After Disconnective Surgery: A Longitudinal fMRI and DTI Study.

    Science.gov (United States)

    Rosazza, Cristina; Deleo, Francesco; D'Incerti, Ludovico; Antelmi, Luigi; Tringali, Giovanni; Didato, Giuseppe; Bruzzone, Maria G; Villani, Flavio; Ghielmetti, Francesco

    2018-01-01

    Objective: Mechanisms of motor plasticity are critical to maintain motor functions after cerebral damage. This study explores the mechanisms of motor reorganization occurring before and after surgery in four patients with drug-refractory epilepsy candidate to disconnective surgery. Methods: We studied four patients with early damage, who underwent tailored hemispheric surgery in adulthood, removing the cortical motor areas and disconnecting the corticospinal tract (CST) from the affected hemisphere. Motor functions were assessed clinically, with functional MRI (fMRI) tasks of arm and leg movement and Diffusion Tensor Imaging (DTI) before and after surgery with assessments of up to 3 years. Quantifications of fMRI motor activations and DTI fractional anisotropy (FA) color maps were performed to assess the lateralization of motor network. We hypothesized that lateralization of motor circuits assessed preoperatively with fMRI and DTI was useful to evaluate the motor outcome in these patients. Results: In two cases preoperative DTI-tractography did not reconstruct the CST, and FA-maps were strongly asymmetric. In the other two cases, the affected CST appeared reduced compared to the contralateral one, with modest asymmetry in the FA-maps. fMRI showed different degrees of lateralization of the motor network and the SMA of the intact hemisphere was mostly engaged in all cases. After surgery, patients with a strongly lateralized motor network showed a stable performance. By contrast, a patient with a more bilateral pattern showed worsening of the upper limb function. For all cases, fMRI activations shifted to the intact hemisphere. Structural alterations of motor circuits, observed with FA values, continued beyond 1 year after surgery. Conclusion: In our case series fMRI and DTI could track the longitudinal reorganization of motor functions. In these four patients the more the paretic limbs recruited the intact hemisphere in primary motor and associative areas, the

  16. UNC-Utah NA-MIC Framework for DTI Fiber Tract Analysis

    Directory of Open Access Journals (Sweden)

    Audrey Rose Verde

    2014-01-01

    Full Text Available Diffusion tensor imaging has become an important modality in the field ofneuroimaging to capture changes in micro-organization and to assess white matterintegrity or development. While there exists a number of tractography toolsets,these usually lack tools for preprocessing or to analyze diffusion properties alongthe fiber tracts. Currently, the field is in critical need of a coherent end-to-endtoolset for performing an along-fiber tract analysis, accessible to non-technicalneuroimaging researchers. The UNC-Utah NA-MIC DTI framework represents acoherent, open source, end-to-end toolset for atlas fiber tract based DTI analysisencompassing DICOM data conversion, quality control, atlas building, fibertractography, fiber parameterization, and statistical analysis of diffusionproperties. Most steps utilize graphical user interfaces (GUI to simplifyinteraction and provide an extensive DTI analysis framework for non-technicalresearchers/investigators. We illustrate the use of our framework on a smallsample, cross sectional neuroimaging study of 8 healthy 1-year-old children fromthe Infant Brain Imaging Study (IBIS Network. In this limited test study, weillustrate the power of our method by quantifying the diffusion properties at 1year of age on the genu and splenium fiber tracts.

  17. UNC-Utah NA-MIC framework for DTI fiber tract analysis.

    Science.gov (United States)

    Verde, Audrey R; Budin, Francois; Berger, Jean-Baptiste; Gupta, Aditya; Farzinfar, Mahshid; Kaiser, Adrien; Ahn, Mihye; Johnson, Hans; Matsui, Joy; Hazlett, Heather C; Sharma, Anuja; Goodlett, Casey; Shi, Yundi; Gouttard, Sylvain; Vachet, Clement; Piven, Joseph; Zhu, Hongtu; Gerig, Guido; Styner, Martin

    2014-01-01

    Diffusion tensor imaging has become an important modality in the field of neuroimaging to capture changes in micro-organization and to assess white matter integrity or development. While there exists a number of tractography toolsets, these usually lack tools for preprocessing or to analyze diffusion properties along the fiber tracts. Currently, the field is in critical need of a coherent end-to-end toolset for performing an along-fiber tract analysis, accessible to non-technical neuroimaging researchers. The UNC-Utah NA-MIC DTI framework represents a coherent, open source, end-to-end toolset for atlas fiber tract based DTI analysis encompassing DICOM data conversion, quality control, atlas building, fiber tractography, fiber parameterization, and statistical analysis of diffusion properties. Most steps utilize graphical user interfaces (GUI) to simplify interaction and provide an extensive DTI analysis framework for non-technical researchers/investigators. We illustrate the use of our framework on a small sample, cross sectional neuroimaging study of eight healthy 1-year-old children from the Infant Brain Imaging Study (IBIS) Network. In this limited test study, we illustrate the power of our method by quantifying the diffusion properties at 1 year of age on the genu and splenium fiber tracts.

  18. Human brain functional MRI and DTI visualization with virtual reality.

    Science.gov (United States)

    Chen, Bin; Moreland, John; Zhang, Jingyu

    2011-12-01

    Magnetic resonance diffusion tensor imaging (DTI) and functional MRI (fMRI) are two active research areas in neuroimaging. DTI is sensitive to the anisotropic diffusion of water exerted by its macromolecular environment and has been shown useful in characterizing structures of ordered tissues such as the brain white matter, myocardium, and cartilage. The diffusion tensor provides two new types of information of water diffusion: the magnitude and the spatial orientation of water diffusivity inside the tissue. This information has been used for white matter fiber tracking to review physical neuronal pathways inside the brain. Functional MRI measures brain activations using the hemodynamic response. The statistically derived activation map corresponds to human brain functional activities caused by neuronal activities. The combination of these two methods provides a new way to understand human brain from the anatomical neuronal fiber connectivity to functional activities between different brain regions. In this study, virtual reality (VR) based MR DTI and fMRI visualization with high resolution anatomical image segmentation and registration, ROI definition and neuronal white matter fiber tractography visualization and fMRI activation map integration is proposed. Rationale and methods for producing and distributing stereoscopic videos are also discussed.

  19. Evaluation of low-grade glioma structural changes after chemotherapy using DTI-based histogram analysis and functional diffusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, Antonella; Iadanza, Antonella; Falini, Andrea [San Raffaele Scientific Institute and Vita-Salute San Raffaele University, Neuroradiology Unit and CERMAC, Milano (Italy); Donativi, Marina [University of Salento, Department of Mathematics and Physics ' ' Ennio De Giorgi' ' and A.D.A.M. (Advanced Data Analysis in Medicine), Lecce (Italy); Ruda, Roberta; Bertero, Luca; Soffietti, Riccardo [University of Torino, Department of Neuro-oncology, Turin (Italy); De Nunzio, Giorgio [University of Salento, Department of Mathematics and Physics ' ' Ennio De Giorgi' ' and A.D.A.M. (Advanced Data Analysis in Medicine), Lecce (Italy); INFN (National Institute of Nuclear Physics), Lecce (Italy); Riva, Marco; Bello, Lorenzo [Universita degli Studi di Milano, Milan, and Humanitas Research Hospital, Department of Medical Biotechnology and Translational Medicine, Rozzano, MI (Italy); Rucco, Matteo [University of Camerino, School of Science and Technology, Computer Science Division, Camerino, MC (Italy)

    2016-05-15

    To explore the role of diffusion tensor imaging (DTI)-based histogram analysis and functional diffusion maps (fDMs) in evaluating structural changes of low-grade gliomas (LGGs) receiving temozolomide (TMZ) chemotherapy. Twenty-one LGG patients underwent 3T-MR examinations before and after three and six cycles of dose-dense TMZ, including 3D-fluid-attenuated inversion recovery (FLAIR) sequences and DTI (b = 1000 s/mm{sup 2}, 32 directions). Mean diffusivity (MD), fractional anisotropy (FA), and tensor-decomposition DTI maps (p and q) were obtained. Histogram and fDM analyses were performed on co-registered baseline and post-chemotherapy maps. DTI changes were compared with modifications of tumour area and volume [according to Response Assessment in Neuro-Oncology (RANO) criteria], and seizure response. After three cycles of TMZ, 20/21 patients were stable according to RANO criteria, but DTI changes were observed in all patients (Wilcoxon test, P ≤ 0.03). After six cycles, DTI changes were more pronounced (P ≤ 0.005). Seventy-five percent of patients had early seizure response with significant improvement of DTI values, maintaining stability on FLAIR. Early changes of the 25th percentiles of p and MD predicted final volume change (R{sup 2} = 0.614 and 0.561, P < 0.0005, respectively). TMZ-related changes were located mainly at tumour borders on p and MD fDMs. DTI-based histogram and fDM analyses are useful techniques to evaluate the early effects of TMZ chemotherapy in LGG patients. (orig.)

  20. A novel DTI-QA tool: Automated metric extraction exploiting the sphericity of an agar filled phantom.

    Science.gov (United States)

    Chavez, Sofia; Viviano, Joseph; Zamyadi, Mojdeh; Kingsley, Peter B; Kochunov, Peter; Strother, Stephen; Voineskos, Aristotle

    2018-02-01

    To develop a quality assurance (QA) tool (acquisition guidelines and automated processing) for diffusion tensor imaging (DTI) data using a common agar-based phantom used for fMRI QA. The goal is to produce a comprehensive set of automated, sensitive and robust QA metrics. A readily available agar phantom was scanned with and without parallel imaging reconstruction. Other scanning parameters were matched to the human scans. A central slab made up of either a thick slice or an average of a few slices, was extracted and all processing was performed on that image. The proposed QA relies on the creation of two ROIs for processing: (i) a preset central circular region of interest (ccROI) and (ii) a signal mask for all images in the dataset. The ccROI enables computation of average signal for SNR calculations as well as average FA values. The production of the signal masks enables automated measurements of eddy current and B0 inhomogeneity induced distortions by exploiting the sphericity of the phantom. Also, the signal masks allow automated background localization to assess levels of Nyquist ghosting. The proposed DTI-QA was shown to produce eleven metrics which are robust yet sensitive to image quality changes within site and differences across sites. It can be performed in a reasonable amount of scan time (~15min) and the code for automated processing has been made publicly available. A novel DTI-QA tool has been proposed. It has been applied successfully on data from several scanners/platforms. The novelty lies in the exploitation of the sphericity of the phantom for distortion measurements. Other novel contributions are: the computation of an SNR value per gradient direction for the diffusion weighted images (DWIs) and an SNR value per non-DWI, an automated background detection for the Nyquist ghosting measurement and an error metric reflecting the contribution of EPI instability to the eddy current induced shape changes observed for DWIs. Copyright © 2017 Elsevier

  1. Development of model DTY-104 radon measuring meter

    International Nuclear Information System (INIS)

    Shi Zhixia; Zhang Aiming; Li Yachun; Wang Qingheng

    2000-01-01

    Model DTY-104 radon measuring meter is an improvement on Model DTY-103. 'Difference value method' is used, which has been strictly developed and makes the radon exhalation rate more accurate, instead of using 'simplified difference value method'. The electronic circuit is redesigned and 80C31 single chip processor is used, which makes the operation more convenient and the function strengthened. In a more reasonable manner, the humidity sensor is mounted in the collection chamber. The collection efficiency can be automatically corrected. The technique of exchanging the collection mylar reduces the waiting time and improves work efficiency. The apparatus is applied to the measurement of the radon concentration in the environment and the radon exhalation from the surface of the building materials, walls and ground. The lower detection limit is about 4Bq/m 3 for 222 Rn concentration and 5 x 10 -5 Bq/s/m 2 for 222 Rn exhalation rate

  2. Glaucoma severity affects diffusion tensor imaging (DTI) parameters of the optic nerve and optic radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sidek, S. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Medical Imaging Unit, Faculty of Medicine, Universiti Teknologi MARA, Selangor (Malaysia); Ramli, N. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Rahmat, K., E-mail: katt_xr2000@yahoo.com [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Ramli, N.M.; Abdulrahman, F. [Department of Ophthalmology, Faculty of Medicine, University Malaya, Kuala Lumpur (Malaysia); Tan, L.K. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia)

    2014-08-15

    Objectives: To evaluate whether MR diffusion tensor imaging (DTI) of the optic nerve and optic radiation in glaucoma patients provides parameters to discriminate between mild and severe glaucoma and to determine whether DTI derived indices correlate with retinal nerve fibre layer (RNFL) thickness. Methods: 3-Tesla DTI was performed on 90 subjects (30 normal, 30 mild glaucoma and 30 severe glaucoma subjects) and the FA and MD of the optic nerve and optic radiation were measured. The categorisation into mild and severe glaucoma was done using the Hodapp–Parrish–Anderson (HPA) classification. RNFL thickness was also assessed on all subjects using OCT. Receiver operating characteristic (ROC) analysis and Spearman's correlation coefficient was carried out. Results: FA and MD values in the optic nerve and optic radiation decreased and increased respectively as the disease progressed. FA at the optic nerve had the highest sensitivity (87%) and specificity (80%). FA values displayed the strongest correlation with RNFL thickness in the optic nerve (r = 0.684, p ≤ 0.001) while MD at the optic radiation showed the weakest correlation with RNFL thickness (r = −0.360, p ≤ 0.001). Conclusions: The high sensitivity and specificity of DTI-derived FA values in the optic nerve and the strong correlation between DTI-FA and RNFL thickness suggest that these parameters could serve as indicators of disease severity.

  3. Glaucoma severity affects diffusion tensor imaging (DTI) parameters of the optic nerve and optic radiation

    International Nuclear Information System (INIS)

    Sidek, S.; Ramli, N.; Rahmat, K.; Ramli, N.M.; Abdulrahman, F.; Tan, L.K.

    2014-01-01

    Objectives: To evaluate whether MR diffusion tensor imaging (DTI) of the optic nerve and optic radiation in glaucoma patients provides parameters to discriminate between mild and severe glaucoma and to determine whether DTI derived indices correlate with retinal nerve fibre layer (RNFL) thickness. Methods: 3-Tesla DTI was performed on 90 subjects (30 normal, 30 mild glaucoma and 30 severe glaucoma subjects) and the FA and MD of the optic nerve and optic radiation were measured. The categorisation into mild and severe glaucoma was done using the Hodapp–Parrish–Anderson (HPA) classification. RNFL thickness was also assessed on all subjects using OCT. Receiver operating characteristic (ROC) analysis and Spearman's correlation coefficient was carried out. Results: FA and MD values in the optic nerve and optic radiation decreased and increased respectively as the disease progressed. FA at the optic nerve had the highest sensitivity (87%) and specificity (80%). FA values displayed the strongest correlation with RNFL thickness in the optic nerve (r = 0.684, p ≤ 0.001) while MD at the optic radiation showed the weakest correlation with RNFL thickness (r = −0.360, p ≤ 0.001). Conclusions: The high sensitivity and specificity of DTI-derived FA values in the optic nerve and the strong correlation between DTI-FA and RNFL thickness suggest that these parameters could serve as indicators of disease severity

  4. Preoperative DTI and probabilistic tractography in an amputee with deep brain stimulation for lower limb stump pain.

    Science.gov (United States)

    Owen, S L F; Heath, J; Kringelbach, M L; Stein, J F; Aziz, T Z

    2007-10-01

    This study aimed to find out whether preoperative diffusion tensor imaging (DTI) and probabilistic tractography could help with surgical planning for deep brain stimulation in the periaqueductal/periventricular grey area (PAG/PVG) in a patient with lower leg stump pain. A preoperative DTI was obtained from the patient, who then received DBS surgery in the PAG/PVG area with good pain relief. The postoperative MRI scan showing electrode placement was used to calculate four seed areas to represent the contacts on the Medtronic 3387 electrode. Probabilistic tractography was then performed from the pre-operative DTI image. Tracts were seen to connect to many areas within the pain network from the four different contacts. These initial findings suggest that preoperative DTI scanning and probabilistic tractography may be able to assist surgical planning in the future.

  5. Correlations between Diffusion Tensor Imaging (DTI and Magnetic Resonance Spectroscopy (1H MRS in schizophrenic patients and normal controls

    Directory of Open Access Journals (Sweden)

    Ng Johnny

    2007-06-01

    Full Text Available Abstract Background Evidence suggests that white matter integrity may play an underlying pathophysiological role in schizophrenia. N-acetylaspartate (NAA, as measured by Magnetic Resonance Spectroscopy (MRS, is a neuronal marker and is decreased in white matter lesions and regions of axonal loss. It has also been found to be reduced in the prefrontal and temporal regions in patients with schizophrenia. Diffusion Tensor Imaging (DTI allows one to measure the orientations of axonal tracts as well as the coherence of axonal bundles. DTI is thus sensitive to demyelination and other structural abnormalities. DTI has also shown abnormalities in these regions. Methods MRS and DTI were obtained on 42 healthy subjects and 40 subjects with schizophrenia. The data was analyzed using regions of interests in the Dorso-Lateral Prefrontal white matter, Medial Temporal white matter and Occipital white matter using both imaging modalities. Results NAA was significantly reduced in the patient population in the Medial Temporal regions. DTI anisotropy indices were also reduced in the same Medial Temporal regions. NAA and DTI-anisotropy indices were also correlated in the left medial temporal region. Conclusion Our results implicate defects in the medial temporal white matter in patients with schizophrenia. Moreover, MRS and DTI are complementary modalities for the study of white matter disruptions in patients with schizophrenia.

  6. Machine learning for the assessment of Alzheimer's disease through DTI

    Science.gov (United States)

    Lella, Eufemia; Amoroso, Nicola; Bellotti, Roberto; Diacono, Domenico; La Rocca, Marianna; Maggipinto, Tommaso; Monaco, Alfonso; Tangaro, Sabina

    2017-09-01

    Digital imaging techniques have found several medical applications in the development of computer aided detection systems, especially in neuroimaging. Recent advances in Diffusion Tensor Imaging (DTI) aim to discover biological markers for the early diagnosis of Alzheimer's disease (AD), one of the most widespread neurodegenerative disorders. We explore here how different supervised classification models provide a robust support to the diagnosis of AD patients. We use DTI measures, assessing the structural integrity of white matter (WM) fiber tracts, to reveal patterns of disrupted brain connectivity. In particular, we provide a voxel-wise measure of fractional anisotropy (FA) and mean diffusivity (MD), thus identifying the regions of the brain mostly affected by neurodegeneration, and then computing intensity features to feed supervised classification algorithms. In particular, we evaluate the accuracy of discrimination of AD patients from healthy controls (HC) with a dataset of 80 subjects (40 HC, 40 AD), from the Alzheimer's Disease Neurodegenerative Initiative (ADNI). In this study, we compare three state-of-the-art classification models: Random Forests, Naive Bayes and Support Vector Machines (SVMs). We use a repeated five-fold cross validation framework with nested feature selection to perform a fair comparison between these algorithms and evaluate the information content they provide. Results show that AD patterns are well localized within the brain, thus DTI features can support the AD diagnosis.

  7. Diagnostic value of conventional MRI combined with DTI for neonatal hyperbilirubinemia

    Directory of Open Access Journals (Sweden)

    Ruifang Yan

    2018-04-01

    Full Text Available Background: Neonatal hyperbilirubinemia (NHB is a common clinical disease and can cause bilirubin encephalopathy in severe cases. It is now widely accepted that increased signal intensity in the globus pallidus on MR T1WI is an important sign of neonatal bilirubin encephalopathy. And brain diffusion tensor imaging (DTI has not been used extensively to study hyperbilirubinemia (HB. So we compared newborns with different hyperbilirubinemia of different severities and healthy newborns in order to determine the relationships among MRI signal intensities, serum bilirubin levels, and the molecular changes in brain water diffusion in hyperbilirubinemia. Methods: Seventy-three newborns with hyperbilirubinemia were grouped into three groups: the mild increase group (M, 27 cases, the moderate increase group (O, 28 cases, and the severe group (S, 18 cases. The groups were based on serum bilirubin levels. We performed cranial MRI in these newborns, as well as 29 healthy full-term infants (group N. We compared and analyzed the mean signal values for the globus pallidus and the relationship between the bilirubin level and the score on the neonatal behavioral neurological assessment. Fifteen, 10, and 10 patients in groups M, O + S, and N were successfully examined using diffusion tensor imaging (DTI. We assessed the relationships among the signal from the globus pallidus, fractional anisotropy (FA, and average diffusion coefficient (DCav of the posterior limb of the internal capsule (PLIC. Results: There were significant differences in the mean signal value of bilateral globus pallidus between group O/S and group N [p = 0.029 and 0.000 (left, 0.038 and 0.000 (right]. There were no significant differences in bilateral FA or DCav values between the patient groups and group N. The bilateral PLIC-FA and DCav values were significantly different between the patient groups and group N (P = 0.014 and 0.047, respectively. Conclusions: Increased signal intensity

  8. White matter mapping by DTI-based tractography for neurosurgery

    International Nuclear Information System (INIS)

    Kamada, Kyousuke

    2009-01-01

    To validate the corticospinal tract (CST) and arcuate fasciculus (AF) illustrated by diffusion tensor imaging (DTI), we used CST- and AF-tractography integrated neuronavigation and monopolar and bipolar direct fiber stimulation. Forty seven patients with brain lesions adjacent to the CST and AF were studied. During lesion resection, direct fiber stimulation was applied to the CST and AF to elicit motor responses (fiber-motor evoked potential (MEP)) and the impairment of language-related functions to identify the CST and AF. The minimum distance between the resection border and illustrated CST was measured on postoperative images. Direct fiber stimulation demonstrated that CST- and AF-tractography accurately reflected anatomical CST functioning. The cortical stimulation to the gyrus, including the language-functional MRI (fMRI) activation, evoked speech arrest, while the subcortical stimulation close to the AF reproducibly caused 'paranomia' without speech arrest. There were strong correlations between stimulus intensity for the fiber-MEP and the distance between eloquent fibers and the stimulus points. The convergent calculation formulated 1.8 mA as the electrical threshold of CST for the fiber-MEP, which was much smaller than that of the hand motor area. Validated tractography demonstrated the mean distance and intersection angle between CST and AF were 5 mm and 107 deg, respectively. In addition, the anisotropic diffusion-weighted image (ADWI) and CST-tractography clearly indicated the locations of the primary motor area (PMA) and the central sulcus and well reflected the anatomical characteristics of the corticospinal tract in the human brain. DTI-based tractography is a reliable way to map the white matter connections in the entire brain in clinical and basic neuroscience. By combining these techniques, investigating the cortico-subcortical connections in the human central nervous system could contribute to elucidating the neural networks of the human brain and

  9. White matter mapping by DTI-based tractography for neurosurgery

    International Nuclear Information System (INIS)

    Kamada, Kyousuke

    2011-01-01

    The purpose of this study was to validate the corticospinal tract (CST) and arcuate fasciculus (AF) illustrated by diffusion tensor imaging (DTI), we used CST- and AF-tractography integrated neuronavigation and monopolar and bipolar direct fiber stimulation. Forty seven patients with brain lesions adjacent to the CST and AF were studied. During lesion resection, direct fiber stimulation was applied to the CST and AF to elicit motor responses (fiber-MEP) and the impairment of language-related functions to identify the CST and AF. The minimum distance between the resection border and illustrated CST was measured on postoperative images. Direct fiber stimulation demonstrated that CST- and AF-tractography accurately reflected anatomical CST functioning. The cortical stimulation to the gyrus, including the language-fMRI activation, evoked speech arrest, while the subcortical stimulation close to the AF reproducibly caused 'paranomia' without speech arrest. There were strong correlations between stimulus intensity for the fiber-MEP and the distance between eloquent fibers and the stimulus points. The convergent calculation formulated 1.8 mA as the electrical threshold of CST for the fiber-MEP, which was much smaller than that of the hand motor area. Validated tractography demonstrated the mean distance and intersection angle between CST and AF were 5 mm and 107 deg, respectively. In addition, the anisotropic diffusion-weighted image (ADWI) and CST-tractography clearly indicated the locations of the primary motor area (PMA) and the central sulcus and well reflected the anatomical characteristics of the corticospinal tract in the human brain. DTI-based tractography is a reliable way to map the white matter connections in the entire brain in clinical and basic neuroscience. By combining these techniques, investigating the cortico-subcortical connections in the human central nervous system could contribute to elucidating the neural networks of the human brain and shed light

  10. Diffusion tensor imaging and neuromodulation: DTI as key technology for deep brain stimulation.

    Science.gov (United States)

    Coenen, Volker Arnd; Schlaepfer, Thomas E; Allert, Niels; Mädler, Burkhard

    2012-01-01

    Diffusion tensor imaging (DTI) is more than just a useful adjunct to invasive techniques like optogenetics which recently have tremendously influenced our understanding of the mechanisms of deep brain stimulation (DBS). In combination with other technologies, DTI helps us to understand which parts of the brain tissue are connected to others and which ones are truly influenced with neuromodulation. The complex interaction of DBS with the surrounding tissues-scrutinized with DTI-allows to create testable hypotheses that can explain network interactions. Those interactions are vital for our understanding of the net effects of neuromodulation. This work naturally was first done in the field of movement disorder surgery, where a lot of experience regarding therapeutic effects and only a short latency between initiation of neuromodulation and alleviation of symptoms exist. This chapter shows the journey over the past 10 years with first applications in DBS toward current research in affect regulating network balances and their therapeutic alterations with the neuromodulation technology. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Correlation of force control with regional spinal DTI in patients with cervical spondylosis without signs of spinal cord injury on conventional MRI

    International Nuclear Information System (INIS)

    Lindberg, Paavel G.; Sanchez, Katherine; Rannou, Francois; Poiraudeau, Serge; Ozcan, Fidan; Feydy, Antoine; Maier, Marc A.

    2016-01-01

    The aim of this study was to investigate spinal cord structure in patients with cervical spondylosis where conventional MRI fails to reveal spinal cord damage. We performed a cross-sectional study of patients with cervical spondylosis without conventional MRI findings of spinal cord damage and healthy controls. Subjects were studied using spinal diffusion tensor imaging (DTI), precision grip and foot force-tracking tasks, and a clinical examination including assessment of neurological signs. A regional analysis of lateral and medial spinal white matter across multiple cervical levels (C1-C5) was performed. DTI revealed reduced fractional anisotropy (FA) and increased radial diffusivity (RD) in the lateral spinal cord at the level of greatest compression (lowest Pavlov ratio) in patients (p < 0.05). Patients with spondylosis had greater error and longer release duration in both grip and foot force-tracking. Similar spinal cord deficits were present in patients without neurological signs. Increased error in grip and foot tracking (low accuracy) correlated with increased RD in the lateral spinal cord at the level of greatest compression (p ≤ 0.01). Spinal DTI can detect subtle spinal cord damage of functional relevance in cervical spondylosis, even in patients without signs on conventional T2-imaging and without neurological signs. (orig.)

  12. Correlation of force control with regional spinal DTI in patients with cervical spondylosis without signs of spinal cord injury on conventional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lindberg, Paavel G. [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Centre de Psychiatrie et Neurosciences, Inserm U894, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Descartes, Service de Radiologie B, APHP, CHU Cochin, Faculte de Medecine, Paris (France); Sanchez, Katherine; Rannou, Francois; Poiraudeau, Serge [Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Service de Medecine Physique et de Readaptation, APHP, CHU Cochin, Paris (France); INSERM U1153 Epidemiologie Clinique des Maladies Osteo-Articulaires, Paris (France); Ozcan, Fidan [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Feydy, Antoine [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Descartes, Service de Radiologie B, APHP, CHU Cochin, Faculte de Medecine, Paris (France); Maier, Marc A. [Universite Paris Descartes, Sorbonne Paris Cite, FR 3636 Neurosciences, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Paris (France); Universite Paris Diderot, Sorbonne Paris Cite, Paris (France)

    2016-03-15

    The aim of this study was to investigate spinal cord structure in patients with cervical spondylosis where conventional MRI fails to reveal spinal cord damage. We performed a cross-sectional study of patients with cervical spondylosis without conventional MRI findings of spinal cord damage and healthy controls. Subjects were studied using spinal diffusion tensor imaging (DTI), precision grip and foot force-tracking tasks, and a clinical examination including assessment of neurological signs. A regional analysis of lateral and medial spinal white matter across multiple cervical levels (C1-C5) was performed. DTI revealed reduced fractional anisotropy (FA) and increased radial diffusivity (RD) in the lateral spinal cord at the level of greatest compression (lowest Pavlov ratio) in patients (p < 0.05). Patients with spondylosis had greater error and longer release duration in both grip and foot force-tracking. Similar spinal cord deficits were present in patients without neurological signs. Increased error in grip and foot tracking (low accuracy) correlated with increased RD in the lateral spinal cord at the level of greatest compression (p ≤ 0.01). Spinal DTI can detect subtle spinal cord damage of functional relevance in cervical spondylosis, even in patients without signs on conventional T2-imaging and without neurological signs. (orig.)

  13. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    International Nuclear Information System (INIS)

    Zijta, F.M.; Froeling, M.; Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J.; Lakeman, M.M.E.; Montauban van Swijndregt, A.D.; Strijkers, G.J.

    2011-01-01

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 ± 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues (λ1, λ2, λ3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 ± 0.02 to 0.30 ± 0.04, MD values from 1.30 ± 0.08 to 1.73 ± 0.12 x 10- 3 mm 2 /s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  14. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Zijta, F.M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Froeling, M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands); Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Lakeman, M.M.E. [University of Amsterdam, Department of Gynaecology, Academic Medical Center, Amsterdam (Netherlands); Montauban van Swijndregt, A.D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Strijkers, G.J. [Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands)

    2011-06-15

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 {+-} 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues ({lambda}1, {lambda}2, {lambda}3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 {+-} 0.02 to 0.30 {+-} 0.04, MD values from 1.30 {+-} 0.08 to 1.73 {+-} 0.12 x 10-{sup 3} mm{sup 2}/s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  15. Combination of Resting state fMRI, DTI and sMRI Data to Discriminate Schizophrenia by N-way MCCA+jICA

    Directory of Open Access Journals (Sweden)

    Jing eSui

    2013-05-01

    Full Text Available Multimodal brain imaging data have shown increasing utility in answering both scientifically interesting and clinically relevant questions. Each brain imaging technique provides a different view of brain function or structure, while multimodal fusion capitalizes on the strength of each and may uncover hidden relationships that can merge findings from separate neuroimaging studies. However, most current approaches have focused on pair-wise fusion and there is still relatively little work on N-way data fusion and examination of the relationships among multiple data types. We recently developed an approach called mCCA+jICA" as a novel multi-way fusion method which is able to investigate the disease risk factors that are either shared or distinct across multiple modalities as well as the full correspondence across modalities. In this paper, we applied this model to combine resting state fMRI (amplitude of low-frequency fluctuation, ALFF, grey matter density (GM and DTI (fractional anisotropy, FA data, in order to elucidate the abnormalities underlying schizophrenia patients (SZs, n=35 relative to healthy controls (HCs, n=28. Both modality-common and modality-unique abnormal regions were identified in SZs, which were then used for successful classification for 7 modality-combinations, showing the potential for a broad applicability of the mCCA+jICA model and its results. In addition, a pair of GM-DTI components showed significant correlation with the positive symptom subscale of Positive and Negative Syndrome Scale (PANSS, suggesting that gray matter density changes in default model network along with white matter disruption in anterior thalamic radiation are associated with increased positive PANSS. Findings suggest the DTI anisotropy changes in frontal lobe may relate to the corresponding functional/structural changes in prefrontal cortex and superior temporal gyrus that are thought to play a role in the clinical expression of schizophrenia.

  16. The effect of short-term workshop on improving clinical reasoning skill of medical students.

    Science.gov (United States)

    Yousefichaijan, Parsa; Jafari, Farshad; Kahbazi, Manijeh; Rafiei, Mohammad; Pakniyat, AbdolGhader

    2016-01-01

    Clinical reasoning process leads clinician to get purposeful steps from signs and symptoms toward diagnosis and treatment. This research intends to investigate the effect of teaching clinical reasoning on problem-solving skills of medical students. This research is a semi-experimental study. Nineteen Medical student of the pediatric ward as case group participated in a two-day workshop for training clinical reasoning. Before the workshop, they filled out Diagnostic Thinking Inventory (DTI) questionnaires. Fifteen days after the workshop the DTI questionnaire completed and "key feature" (KF) test and "clinical reasoning problem" (CRP) test was held. 23 Medical student as the control group, without passing the clinical reasoning workshop DTI questionnaire completed, and KF test and CRP test was held. The average score of the DTI questionnaire in the control group was 162.04 and in the case group before the workshop was 153.26 and after the workshop was 181.68. Compare the average score of the DTI questionnaire before and after the workshop there is a significant difference. The difference between average KF test scores in the control and the case group was not significant but between average CRP test scores was significant. Clinical reasoning workshop is effectiveness in promoting problem-solving skills of students.

  17. Diffusion tensor MR imaging (DTI) metrics in the cervical spinal cord in asymptomatic HIV-positive patients

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Mang, Christina; Mang, Thomas; Fruehwald-Pallamar, Julia; Weber, Michael; Thurnher, Majda M. [Medical University of Vienna, Department of Radiology, Vienna (Austria); Law, Meng [University of Southern California, Los Angeles County Hospital and USC Medical Center, Department of Radiology, Keck School of Medicine, Los Angeles, CA (United States)

    2011-08-15

    This study was conducted to compare diffusion tensor MR imaging (DTI) metrics of the cervical spinal cord in asymptomatic human immunodeficiency virus (HIV)-positive patients with those measured in healthy volunteers, and to assess whether DTI is a valuable diagnostic tool in the early detection of HIV-associated myelopathy (HIVM). MR imaging of the cervical spinal cord was performed in 20 asymptomatic HIV-positive patients and in 20 healthy volunteers on a 3-T MR scanner. Average fractional anisotropy (FA), mean diffusivity (MD), and major (E1) and minor (E2, E3) eigenvalues were calculated within regions of interest (ROIs) at the C2/3 level (central and bilateral anterior, lateral and posterior white matter). Statistical analysis showed significant differences with regard to mean E3 values between patients and controls (p = 0.045; mixed-model analysis of variance (ANOVA) test). Mean FA was lower, and mean MD, mean E1, and mean E2 were higher in each measured ROI in patients compared to controls, but these differences were not statistically significant. Asymptomatic HIV-positive patients demonstrate only subtle changes in DTI metrics measured in the cervical spinal cord compared to healthy volunteers that currently do not support using DTI as a diagnostic tool for the early detection of HIVM. (orig.)

  18. Analysis of DTI-Derived Tensor Metrics in Differential Diagnosis between Low-grade and High-grade Gliomas.

    Science.gov (United States)

    Jiang, Liang; Xiao, Chao-Yong; Xu, Quan; Sun, Jun; Chen, Huiyou; Chen, Yu-Chen; Yin, Xindao

    2017-01-01

    Purpose: It is critical and difficult to accurately discriminate between high- and low-grade gliomas preoperatively. This study aimed to ascertain the role of several scalar measures in distinguishing high-grade from low-grade gliomas, especially the axial diffusivity (AD), radial diffusivity (RD), planar tensor (Cp), spherical tensor (Cs), and linear tensor (Cl) derived from diffusion tensor imaging (DTI). Materials and Methods: Fifty-three patients with pathologically confirmed brain gliomas (21 low-grade and 32 high-grade) were included. Contrast-enhanced T1-weighted images and DTI were performed in all patients. The AD, RD, Cp, Cs, and Cl values in the tumor zone, peritumoral edema zone, white matter (WM) adjacent to edema and contralateral normal-appearing white matter (NAWM) were calculated. The DTI parameters and tumor grades were statistically analyzed, and receiver operating characteristic (ROC) curve analysis was also performed. Results: The DTI metrics in the affected hemisphere showed significant differences from those in the NAWM, except for the AD values in the tumor zone and the RD values in WM adjacent to edema in the low-grade groups, as well as the Cp values in WM adjacent to edema in the high-grade groups. AD in the tumor zone as well as Cs and Cl in WM adjacent to edema revealed significant differences between the low- and high-grade gliomas. The areas under the curve (Az) of all three metrics were greater than 0.5 in distinguishing low-grade from high-grade gliomas by ROC curve analysis, and the best DTI metric was Cs in WM adjacent to edema (Az: 0.692). Conclusion: AD in the tumor zone as well as Cs and Cl in WM adjacent to edema will provide additional information to better classify gliomas and can be used as non-invasive reliable biomarkers in glioma grading.

  19. Does the use of hormonal contraceptives cause microstructural changes in cerebral white matter? Preliminary results of a DTI and tractography study.

    Science.gov (United States)

    De Bondt, Timo; Van Hecke, Wim; Veraart, Jelle; Leemans, Alexander; Sijbers, Jan; Sunaert, Stefan; Jacquemyn, Yves; Parizel, Paul M

    2013-01-01

    To evaluate the effect of monophasic combined oral contraceptive pill (COCP) and menstrual cycle phase in healthy young women on white matter (WM) organization using diffusion tensor imaging (DTI). Thirty young women were included in the study; 15 women used COCP and 15 women had a natural cycle. All subjects underwent DTI magnetic resonance imaging during the follicular and luteal phase of their cycle, or in different COCP cycle phases. DTI parameters were obtained in different WM structures by performing diffusion tensor fibre tractography. Fractional anisotropy and mean diffusivity were calculated for different WM structures. Hormonal plasma concentrations were measured in peripheral venous blood samples and correlated with the DTI findings. We found a significant difference in mean diffusivity in the fornix between the COCP and the natural cycle group. Mean diffusivity values in the fornix were negatively correlated with luteinizing hormone and estradiol blood concentrations. An important part in the limbic system, the fornix, regulates emotional processes. Differences in diffusion parameters in the fornix may contribute to behavioural alternations related to COCP use. This finding also suggests that the use of oral contraceptives needs to be taken into account when designing DTI group studies.

  20. Functional neuroimaging correlates of thinking flexibility and knowledge structure in memory: Exploring the relationships between clinical reasoning and diagnostic thinking.

    Science.gov (United States)

    Durning, Steven J; Costanzo, Michelle E; Beckman, Thomas J; Artino, Anthony R; Roy, Michael J; van der Vleuten, Cees; Holmboe, Eric S; Lipner, Rebecca S; Schuwirth, Lambert

    2016-06-01

    Diagnostic reasoning involves the thinking steps up to and including arrival at a diagnosis. Dual process theory posits that a physician's thinking is based on both non-analytic or fast, subconscious thinking and analytic thinking that is slower, more conscious, effortful and characterized by comparing and contrasting alternatives. Expertise in clinical reasoning may relate to the two dimensions measured by the diagnostic thinking inventory (DTI): memory structure and flexibility in thinking. Explored the functional magnetic resonance imaging (fMRI) correlates of these two aspects of the DTI: memory structure and flexibility of thinking. Participants answered and reflected upon multiple-choice questions (MCQs) during fMRI. A DTI was completed shortly after the scan. The brain processes associated with the two dimensions of the DTI were correlated with fMRI phases - assessing flexibility in thinking during analytical clinical reasoning, memory structure during non-analytical clinical reasoning and the total DTI during both non-analytical and analytical reasoning in experienced physicians. Each DTI component was associated with distinct functional neuroanatomic activation patterns, particularly in the prefrontal cortex. Our findings support diagnostic thinking conceptual models and indicate mechanisms through which cognitive demands may induce functional adaptation within the prefrontal cortex. This provides additional objective validity evidence for the use of the DTI in medical education and practice settings.

  1. Functional MRI, DTI and neurophysiology in horizontal gaze palsy with progressive scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Sven; Wetzel, Stephan G. [University Hospital Basel, Institute of Radiology, Department of Neuroradiology, Basel (Switzerland); Luetschg, Juerg [University Children' s Hospital (UKBB), Basel (Switzerland)

    2008-05-15

    Horizontal gaze palsy with progressive scoliosis (HGPPS) is an autosomal recessive disease due to a mutation in the ROBO3 gene. This rare disease is of particular interest because the absence, or at least reduction, of crossing of the ascending lemniscal and descending corticospinal tracts in the medulla predicts abnormal ipsilateral sensory and motor systems. We evaluated the use of functional magnetic resonance imaging (fMRI) for the first time in this disease and compared it to diffusion tensor imaging (DTI) tractography and neurophysiological findings in the same patient with genetically confirmed ROBO3 mutation. As expected, motor fMRI, somatosensory evoked potentials (SSEP) and motor evoked potentials (MEP) were dominantly ipsilateral to the stimulation side. DTI tractography revealed ipsilateral ascending and descending connectivity in the brainstem yet normal interhemispheric connections in the corpus callosum. Auditory fMRI revealed bilateral auditory activation to monaural left-sided auditory stimulation. No significant cortical activation was observed after monaural right-sided stimulation, a hearing defect having been excluded. Prosaccades fMRI showed no activations in the eye-movement network. Motor fMRI confirmed the established findings of DTI and neurophysiology in the same patient. In suspected HGPPS, any technique appears appropriate for further investigation. Auditory fMRI suggests that a monaural auditory system with bilateral auditory activations might be a physiological advantage as compared to a binaural yet only unilateral auditory system, in analogy to anisometropic amblyopia. Moving-head fMRI studies in the future might show whether the compensatory head movements instead of normal eye movements activate the eye-movement network. (orig.)

  2. Functional MRI, DTI and neurophysiology in horizontal gaze palsy with progressive scoliosis

    International Nuclear Information System (INIS)

    Haller, Sven; Wetzel, Stephan G.; Luetschg, Juerg

    2008-01-01

    Horizontal gaze palsy with progressive scoliosis (HGPPS) is an autosomal recessive disease due to a mutation in the ROBO3 gene. This rare disease is of particular interest because the absence, or at least reduction, of crossing of the ascending lemniscal and descending corticospinal tracts in the medulla predicts abnormal ipsilateral sensory and motor systems. We evaluated the use of functional magnetic resonance imaging (fMRI) for the first time in this disease and compared it to diffusion tensor imaging (DTI) tractography and neurophysiological findings in the same patient with genetically confirmed ROBO3 mutation. As expected, motor fMRI, somatosensory evoked potentials (SSEP) and motor evoked potentials (MEP) were dominantly ipsilateral to the stimulation side. DTI tractography revealed ipsilateral ascending and descending connectivity in the brainstem yet normal interhemispheric connections in the corpus callosum. Auditory fMRI revealed bilateral auditory activation to monaural left-sided auditory stimulation. No significant cortical activation was observed after monaural right-sided stimulation, a hearing defect having been excluded. Prosaccades fMRI showed no activations in the eye-movement network. Motor fMRI confirmed the established findings of DTI and neurophysiology in the same patient. In suspected HGPPS, any technique appears appropriate for further investigation. Auditory fMRI suggests that a monaural auditory system with bilateral auditory activations might be a physiological advantage as compared to a binaural yet only unilateral auditory system, in analogy to anisometropic amblyopia. Moving-head fMRI studies in the future might show whether the compensatory head movements instead of normal eye movements activate the eye-movement network. (orig.)

  3. Functional MRI, DTI and neurophysiology in horizontal gaze palsy with progressive scoliosis.

    Science.gov (United States)

    Haller, Sven; Wetzel, Stephan G; Lütschg, Jürg

    2008-05-01

    Horizontal gaze palsy with progressive scoliosis (HGPPS) is an autosomal recessive disease due to a mutation in the ROBO3 gene. This rare disease is of particular interest because the absence, or at least reduction, of crossing of the ascending lemniscal and descending corticospinal tracts in the medulla predicts abnormal ipsilateral sensory and motor systems. We evaluated the use of functional magnetic resonance imaging (fMRI) for the first time in this disease and compared it to diffusion tensor imaging (DTI) tractography and neurophysiological findings in the same patient with genetically confirmed ROBO3 mutation. As expected, motor fMRI, somatosensory evoked potentials (SSEP) and motor evoked potentials (MEP) were dominantly ipsilateral to the stimulation side. DTI tractography revealed ipsilateral ascending and descending connectivity in the brainstem yet normal interhemispheric connections in the corpus callosum. Auditory fMRI revealed bilateral auditory activation to monaural left-sided auditory stimulation. No significant cortical activation was observed after monaural right-sided stimulation, a hearing defect having been excluded. Prosaccades fMRI showed no activations in the eye-movement network. Motor fMRI confirmed the established findings of DTI and neurophysiology in the same patient. In suspected HGPPS, any technique appears appropriate for further investigation. Auditory fMRI suggests that a monaural auditory system with bilateral auditory activations might be a physiological advantage as compared to a binaural yet only unilateral auditory system, in analogy to anisometropic amblyopia. Moving-head fMRI studies in the future might show whether the compensatory head movements instead of normal eye movements activate the eye-movement network.

  4. Structural brain alterations of Down's syndrome in early childhood evaluation by DTI and volumetric analyses

    International Nuclear Information System (INIS)

    Gunbey, Hediye Pinar; Bilgici, Meltem Ceyhan; Aslan, Kerim; Incesu, Lutfi; Has, Arzu Ceylan; Ogur, Methiye Gonul; Alhan, Aslihan

    2017-01-01

    To provide an initial assessment of white matter (WM) integrity with diffusion tensor imaging (DTI) and the accompanying volumetric changes in WM and grey matter (GM) through volumetric analyses of young children with Down's syndrome (DS). Ten children with DS and eight healthy control subjects were included in the study. Tract-based spatial statistics (TBSS) were used in the DTI study for whole-brain voxelwise analysis of fractional anisotropy (FA) and mean diffusivity (MD) of WM. Volumetric analyses were performed with an automated segmentation method to obtain regional measurements of cortical volumes. Children with DS showed significantly reduced FA in association tracts of the fronto-temporo-occipital regions as well as the corpus callosum (CC) and anterior limb of the internal capsule (p < 0.05). Volumetric reductions included total cortical GM, cerebellar GM and WM volume, basal ganglia, thalamus, brainstem and CC in DS compared with controls (p < 0.05). These preliminary results suggest that DTI and volumetric analyses may reflect the earliest complementary changes of the neurodevelopmental delay in children with DS and can serve as surrogate biomarkers of the specific elements of WM and GM integrity for cognitive development. (orig.)

  5. Diffusion abnormality maps in demyelinating disease: Correlations with clinical scores

    International Nuclear Information System (INIS)

    Onu, Mihaela; Roceanu, Adina; Sboto-Frankenstein, Uta; Bendic, Robert; Tarta, Eugen; Preoteasa, Florentin; Bajenaru, Ovidiu

    2012-01-01

    Background and purpose: Magnetic resonance imaging (MRI) has been explored as a noninvasive tool to assess pathology in multiple sclerosis (MS) patients. However, the correlation between classical MRI measures and physical disability is modest in MS. The diffusion tensor imaging (DTI) MRI technique holds particular promise in this regard. The present study shows brain regions where FA and individual diffusivities abnormalities are present and check their correlations with physical disability clinical scores. Methods: Eight patients and 12 matched healthy controls were recruited. The Multiple Sclerosis Functional Composite was administered. For MR-DTI acquisitions, a Genesis Signa 1.5T MR system, an EP/SE scanning sequence, 25 gradient directions were used. Results: Tract Based Spatial Statistics (TBSS) group comparisons showed reduced FA and increased individual diffusivities in several brain regions in patients. Significant correlations were found between FA and: EDSS, 9-HPT(NON)DOM and 25FW score; between λ 2 and: P100 (r and l), 9-HPT(NON)DOM and 25FW; between λ 3 and: 9-HPT(NON)DOM and 25FW score. Conclusions: Fractional anisotropy and individual radial diffusivities proved to be important markers of motor disabilities in MS patients when the disease duration mean and the disability scores values range are relatively high.

  6. Harmonizing DTI measurements across scanners to examine the development of white matter microstructure in 803 adolescents of the NCANDA study.

    Science.gov (United States)

    Pohl, Kilian M; Sullivan, Edith V; Rohlfing, Torsten; Chu, Weiwei; Kwon, Dongjin; Nichols, B Nolan; Zhang, Yong; Brown, Sandra A; Tapert, Susan F; Cummins, Kevin; Thompson, Wesley K; Brumback, Ty; Colrain, Ian M; Baker, Fiona C; Prouty, Devin; De Bellis, Michael D; Voyvodic, James T; Clark, Duncan B; Schirda, Claudiu; Nagel, Bonnie J; Pfefferbaum, Adolf

    2016-04-15

    notable in the boys. The contribution of demographic and clinical differences to DTI metrics was assessed with General Additive Models (GAM) testing for age, sex, and ethnicity differences in regional skeleton mean values. The results supported the primary study hypothesis that FA skeleton mean values in the no/low-drinking group were highest at different ages. When differences in intracranial volume were covaried, FA skeleton mean reached a maximum at younger ages in girls than boys and varied in magnitude with ethnicity. Our results, however, did not support the hypothesis that youth who exceeded exposure criteria would have lower FA or higher diffusivity measures than the no/low-drinking group; detecting the effects of excessive alcohol consumption during adolescence on DTI metrics may require longitudinal study. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. MRI assessment of the thigh musculature in dermatomyositis and healthy subjects using diffusion tensor imaging, intravoxel incoherent motion and dynamic DTI.

    Science.gov (United States)

    Sigmund, E E; Baete, S H; Luo, T; Patel, K; Wang, D; Rossi, I; Duarte, A; Bruno, M; Mossa, D; Femia, A; Ramachandran, S; Stoffel, D; Babb, J S; Franks, A; Bencardino, J

    2018-06-04

    Dermatomyositis (DM) is an idiopathic inflammatory myopathy involving severe debilitation in need of diagnostics. We evaluated the proximal lower extremity musculature with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM) and dynamic DTI in DM patients and controls and compared with standard clinical workup.  METHODS: In this IRB-approved, HIPAA-compliant study with written informed consent, anatomical, Dixon fat/water and diffusion imaging were collected in bilateral thigh MRI of 22 controls and 27 DM patients in a 3T scanner. Compartments were scored on T1/T2 scales. Single voxel dynamic DTI metrics in quadriceps before and after 3-min leg exercise were measured. Spearman rank correlation and mixed model analysis of variance/covariance (ANOVA/ANCOVA) were used to correlate with T1 and T2 scores and to compare patients with controls. DM patients showed significantly lower pseudo-diffusion and volume in quadriceps than controls. All subjects showed significant correlation between T1 score and signal-weighted fat fraction; tissue diffusion and pseudo-diffusion varied significantly with T1 and T2 score in patients. Radial and mean diffusion exercise response in patients was significantly higher than controls. Static and dynamic diffusion imaging metrics show correlation with conventional imaging scores, reveal spatial heterogeneity, and provide means to differentiate dermatomyositis patients from controls. • Diffusion imaging shows regional differences between thigh muscles of dermatomyositis patients and controls. • Signal-weighted fat fraction and diffusion metrics correlate with T1/T2 scores of disease severity. • Dermatomyositis patients show significantly higher radial diffusion exercise response than controls.

  8. Cerebral metabolic and structural alterations in hereditary spastic paraplegia with thin corpus callosum assessed by MRS and DTI

    International Nuclear Information System (INIS)

    Dreha-Kulaczewski, Steffi; Dechent, Peter; Helms, Gunther; Frahm, Jens; Gaertner, Jutta; Brockmann, Knut

    2006-01-01

    Hereditary spastic paraplegia with thin corpus callosum (HSP-TCC) is a complicated form of autosomal-recessive hereditary spastic paraplegia. Characteristic clinical features comprise progressive spastic gait, cognitive impairment, and ataxia. Diagnostic MRI findings include thinning of the corpus callosum and non-progressive white matter (WM) alterations. To study the extent of axonal involvement, we performed localized proton magnetic resonance spectroscopy (MRS) of the cerebral WM and cortical grey matter (GM) in a patient with HSP-TCC at 20 and 25 years of age. The second investigation included diffusion tensor imaging (DTI). While MRS of the GM was normal, affected WM was characterized by major metabolic alterations such as reduced concentrations of N-acetylaspartate and N-acetylaspartyl-glutamate, creatine and phosphocreatine, and choline-containing compounds as well as elevated levels of myo-inositol. These abnormalities showed progression over a period of 5 years. DTI revealed increased mean diffusivity as well as reduced fractional anisotropy in periventricular WM. The metabolic and structural findings are consistent with progressive neuroaxonal loss in the WM accompanied by astrocytic proliferation - histopathological changes known to occur in HSP-TCC. Our results are in agreement with the hypothesis that the primary pathological process in HSP-TCC affects the axon, possibly due to impaired axonal trafficking. (orig.)

  9. MARCHIAFAVA-BIGNAMI DISEASE (MBD AND DIFFUSION TENSOR IMAGE (DTI TRACTOGRAPHY

    Directory of Open Access Journals (Sweden)

    Priscilla Chukwueke

    2015-06-01

    Full Text Available Marchiafava-Bignami Disease (MBD is a rare central nervous system (CNS disease characterized by demyelination of the corpus callosum. It is mostly found in men with alcohol use disorder and malnutrition with cases reported worldwide across all races. The onset of the disease may be sudden presenting with stupor, coma or seizures while some may present with gait abnormality (spasticity, psychiatric problems, hemiparesis, aphasia, apraxia and incontinence with a resultant high morbidity and mortality rates. Case description: patient is a 30 year old left handed African-American, who presented with c/o altered mental status, urinary incontinence, slurred speech and left-sided weakness. The diagnosis of MBD was confirmed with DTI Tractography which showed significantly diminished commissural fibers extending to the right central semiovale lesion, near absent or significantly diminished commissural fiber extending through the corpus callosum indicating demyelination. Discussion: MBD is often an incidental diagnosis with high morbidity and mortality. This is different from previous casas because of earlier onset as opposed to onset around age 45, rapid recovery and minimal disability as he could walk independently before discharge from hospital. This case also shows added benefit of the DTI tractography in the diagnosis of MBD.

  10. Histogram analysis of diffusion measures in clinically isolated syndromes and relapsing-remitting multiple sclerosis

    International Nuclear Information System (INIS)

    Yu Chunshui; Lin Fuchun; Liu Yaou; Duan Yunyun; Lei Hao; Li Kuncheng

    2008-01-01

    Objective: The purposes of our study were to employ diffusion tensor imaging (DTI)-based histogram analysis to determine the presence of occult damage in clinically isolated syndrome (CIS), to compare its severity with relapsing-remitting multiple sclerosis (RRMS), and to determine correlations between DTI histogram measures and clinical and MRI indices in these two diseases. Materials and methods: DTI scans were performed in 19 CIS and 19 RRMS patients and 19 matched healthy volunteers. Histogram analyses of mean diffusivity and fractional anisotropy were performed in normal-appearing brain tissue (NABT), normal-appearing white matter (NAWM) and gray matter (NAGM). Correlations were analyzed between these measures and expanded disability status scale (EDSS) scores, T 2 WI lesion volumes (LV) and normalized brain tissue volumes (NBTV) in CIS and RRMS patients. Results: Significant differences were found among CIS, RRMS and control groups in the NBTV and most of the DTI histogram measures of the NABT, NAWM and NAGM. In CIS patients, some DTI histogram measures showed significant correlations with LV and NBTV, but none of them with EDSS. In RRMS patients, however, some DTI histogram measures were significantly correlated with LV, NBTV and EDSS. Conclusion: Occult damage occurs in both NAGM and NAWM in CIS, but the severity is milder than that in RRMS. In CIS and RRMS, the occult damage might be related to both T2 lesion load and brain tissue atrophy. Some DTI histogram measures might be useful for assessing the disease progression in RRMS patients

  11. Quantitative analysis of diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) for brain disorders

    Science.gov (United States)

    Lee, Jae-Seung; Im, In-Chul; Kang, Su-Man; Goo, Eun-Hoe; Kwak, Byung-Joon

    2013-07-01

    This study aimed to quantitatively analyze data from diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) in patients with brain disorders and to assess its potential utility for analyzing brain function. DTI was obtained by performing 3.0-T magnetic resonance imaging for patients with Alzheimer's disease (AD) and vascular dementia (VD), and the data were analyzed using Matlab-based SPM software. The two-sample t-test was used for error analysis of the location of the activated pixels. We compared regions of white matter where the fractional anisotropy (FA) values were low and the apparent diffusion coefficients (ADCs) were increased. In the AD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right sub-lobar insula, and right occipital lingual gyrus whereas the ADCs were significantly increased in the right inferior frontal gyrus and right middle frontal gyrus. In the VD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right limbic cingulate gyrus, and right sub-lobar caudate tail whereas the ADCs were significantly increased in the left lateral globus pallidus and left medial globus pallidus. In conclusion by using DTI and SPM analysis, we were able to not only determine the structural state of the regions affected by brain disorders but also quantitatively analyze and assess brain function.

  12. Progressive decline in fractional anisotropy on serial DTI examinations of the corpus callosum: a putative marker of disease activity and progression in SPMS

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Wei; Zhu, Tong; Zhong, Jianhui; Liu, Xiang [University of Rochester Medical Center, Department of Imaging Sciences, Rochester, NY (United States); Rao, Praveen; Segal, Benjamin M. [University of Michigan, Department of Neurology, Holtom-Garrett Program in Neuroimmunology, Ann Arbor, MI (United States); Ekholm, Sven [University of Rochester Medical Center, Department of Imaging Sciences, Rochester, NY (United States); University of Rochester Medical Center, Division of Diagnostic and Interventional Neuroradiology, Rochester, NY (United States)

    2012-04-15

    Clinical trials of secondary progressive multiple sclerosis (SPMS) is lacking reliable biomarkers or outcome measures that reflect tissue injury incurred within a 1- to 2-year observation period. Diffusion tensor imaging (DTI) is sensitive in detecting acute brain tissue damage. We monitored SPMS patients over 12 months for diffusion changes within the corpus callosum (CC). Bimonthly MRI examinations over a 1-year period were performed on 11 SPMS patients. The protocol included postcontrast T1-weighted images and DTI. Based on the appearance of T1 enhancing lesion(s) during the study period, the patients were divided into enhancing (five patients) and nonenhancing (six patients) groups. Fractional anisotropy (FA) and mean diffusivity (MD) of the genu, body, and splenium of the CC were measured and temporal changes in mean FA and MD were evaluated for each group as well as between groups. Immunology data from peripheral blood mononuclear cells were also collected on a monthly basis. The enhancing group showed significant, progressive decrease in FA in body (p = 0.012) and splenium (p = 0.033) of CC, and significantly higher lymphotoxin-{beta} levels. No significant FA changes were seen in the nonenhancing group. Moreover, the FA decline in the enhancing group deviated significantly from the nonenhancing group, which remained essentially stable. Although MD increased slightly in both groups, there was no significant difference between the two groups. Based on the MR and immunology findings, the results of our study suggest that DTI undergo more rapid and longitudinal changes in SPMS patients with inflammatory activity. (orig.)

  13. Linear associations between clinically assessed upper motor neuron disease and diffusion tensor imaging metrics in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Woo, John H; Wang, Sumei; Melhem, Elias R; Gee, James C; Cucchiara, Andrew; McCluskey, Leo; Elman, Lauren

    2014-01-01

    To assess the relationship between clinically assessed Upper Motor Neuron (UMN) disease in Amyotrophic Lateral Sclerosis (ALS) and local diffusion alterations measured in the brain corticospinal tract (CST) by a tractography-driven template-space region-of-interest (ROI) analysis of Diffusion Tensor Imaging (DTI). This cross-sectional study included 34 patients with ALS, on whom DTI was performed. Clinical measures were separately obtained including the Penn UMN Score, a summary metric based upon standard clinical methods. After normalizing all DTI data to a population-specific template, tractography was performed to determine a region-of-interest (ROI) outlining the CST, in which average Mean Diffusivity (MD) and Fractional Anisotropy (FA) were estimated. Linear regression analyses were used to investigate associations of DTI metrics (MD, FA) with clinical measures (Penn UMN Score, ALSFRS-R, duration-of-disease), along with age, sex, handedness, and El Escorial category as covariates. For MD, the regression model was significant (p = 0.02), and the only significant predictors were the Penn UMN Score (p = 0.005) and age (p = 0.03). The FA regression model was also significant (p = 0.02); the only significant predictor was the Penn UMN Score (p = 0.003). Measured by the template-space ROI method, both MD and FA were linearly associated with the Penn UMN Score, supporting the hypothesis that DTI alterations reflect UMN pathology as assessed by the clinical examination.

  14. Structural brain alterations of Down's syndrome in early childhood evaluation by DTI and volumetric analyses

    Energy Technology Data Exchange (ETDEWEB)

    Gunbey, Hediye Pinar; Bilgici, Meltem Ceyhan; Aslan, Kerim; Incesu, Lutfi [Ondokuz Mayis University, Faculty of Medicine, Department of Radiology, Kurupelit, Samsun (Turkey); Has, Arzu Ceylan [Bilkent University, National Magnetic Resonance Research Center, Ankara (Turkey); Ogur, Methiye Gonul [Ondokuz Mayis University, Department of Genetics, Samsun (Turkey); Alhan, Aslihan [Ufuk University, Department of Statistics, Ankara (Turkey)

    2017-07-15

    To provide an initial assessment of white matter (WM) integrity with diffusion tensor imaging (DTI) and the accompanying volumetric changes in WM and grey matter (GM) through volumetric analyses of young children with Down's syndrome (DS). Ten children with DS and eight healthy control subjects were included in the study. Tract-based spatial statistics (TBSS) were used in the DTI study for whole-brain voxelwise analysis of fractional anisotropy (FA) and mean diffusivity (MD) of WM. Volumetric analyses were performed with an automated segmentation method to obtain regional measurements of cortical volumes. Children with DS showed significantly reduced FA in association tracts of the fronto-temporo-occipital regions as well as the corpus callosum (CC) and anterior limb of the internal capsule (p < 0.05). Volumetric reductions included total cortical GM, cerebellar GM and WM volume, basal ganglia, thalamus, brainstem and CC in DS compared with controls (p < 0.05). These preliminary results suggest that DTI and volumetric analyses may reflect the earliest complementary changes of the neurodevelopmental delay in children with DS and can serve as surrogate biomarkers of the specific elements of WM and GM integrity for cognitive development. (orig.)

  15. The efficiency of retrospective artifact correction methods in improving the statistical power of between-group differences in spinal cord DTI.

    Science.gov (United States)

    David, Gergely; Freund, Patrick; Mohammadi, Siawoosh

    2017-09-01

    Diffusion tensor imaging (DTI) is a promising approach for investigating the white matter microstructure of the spinal cord. However, it suffers from severe susceptibility, physiological, and instrumental artifacts present in the cord. Retrospective correction techniques are popular approaches to reduce these artifacts, because they are widely applicable and do not increase scan time. In this paper, we present a novel outlier rejection approach (reliability masking) which is designed to supplement existing correction approaches by excluding irreversibly corrupted and thus unreliable data points from the DTI index maps. Then, we investigate how chains of retrospective correction techniques including (i) registration, (ii) registration and robust fitting, and (iii) registration, robust fitting, and reliability masking affect the statistical power of a previously reported finding of lower fractional anisotropy values in the posterior column and lateral corticospinal tracts in cervical spondylotic myelopathy (CSM) patients. While established post-processing steps had small effect on the statistical power of the clinical finding (slice-wise registration: -0.5%, robust fitting: +0.6%), adding reliability masking to the post-processing chain increased it by 4.7%. Interestingly, reliability masking and registration affected the t-score metric differently: while the gain in statistical power due to reliability masking was mainly driven by decreased variability in both groups, registration slightly increased variability. In conclusion, reliability masking is particularly attractive for neuroscience and clinical research studies, as it increases statistical power by reducing group variability and thus provides a cost-efficient alternative to increasing the group size. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. White matter alterations in the brains of patients with active, remitted, and cured cushing syndrome: a DTI study.

    Science.gov (United States)

    Pires, P; Santos, A; Vives-Gilabert, Y; Webb, S M; Sainz-Ruiz, A; Resmini, E; Crespo, I; de Juan-Delago, M; Gómez-Anson, B

    2015-06-01

    Cushing syndrome appears after chronic exposure to elevated glucocorticoid levels. Cortisol excess may alter white matter microstructure. Our purpose was to study WM changes in patients with Cushing syndrome compared with controls by using DTI and the influence of hypercortisolism. Thirty-five patients with Cushing syndrome and 35 healthy controls, matched for age, education, and sex, were analyzed through DTI (tract-based spatial statistics) for fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity (general linear model, family-wise error, and threshold-free cluster enhancement corrections, P Cushing syndrome with active hypercortisolism, 7 with Cushing syndrome with medication-remitted cortisol, 20 surgically cured, and 35 controls. Cardiovascular risk factors were used as covariates. In addition, correlations were analyzed among DTI values, concomitant 24-hour urinary free cortisol levels, and disease duration. There were widespread alterations (reduced fractional anisotropy, and increased mean diffusivity, axial diffusivity, and radial diffusivity values; P Cushing syndrome compared with controls, independent of the cardiovascular risk factors present. Both active and cured Cushing syndrome subgroups showed similar changes compared with controls. Patients with medically remitted Cushing syndrome also had reduced fractional anisotropy and increased mean diffusivity and radial diffusivity values, compared with controls. No correlations were found between DTI maps and 24-hour urinary free cortisol levels or with disease duration. Diffuse WM alterations in patients with Cushing syndrome suggest underlying loss of WM integrity and demyelination. Once present, they seem to be independent of concomitant hypercortisolism, persisting after remission/cure. © 2015 by American Journal of Neuroradiology.

  17. Correlation of Diffusion and Metabolic Alterations in Different Clinical Forms of Multiple Sclerosis

    Science.gov (United States)

    Hannoun, Salem; Bagory, Matthieu; Durand-Dubief, Francoise; Ibarrola, Danielle; Comte, Jean-Christophe; Confavreux, Christian; Cotton, Francois; Sappey-Marinier, Dominique

    2012-01-01

    Diffusion tensor imaging (DTI) and MR spectroscopic imaging (MRSI) provide greater sensitivity than conventional MRI to detect diffuse alterations in normal appearing white matter (NAWM) of Multiple Sclerosis (MS) patients with different clinical forms. Therefore, the goal of this study is to combine DTI and MRSI measurements to analyze the relation between diffusion and metabolic markers, T2-weighted lesion load (T2-LL) and the patients clinical status. The sensitivity and specificity of both methods were then compared in terms of MS clinical forms differentiation. MR examination was performed on 71 MS patients (27 relapsing remitting (RR), 26 secondary progressive (SP) and 18 primary progressive (PP)) and 24 control subjects. DTI and MRSI measurements were obtained from two identical regions of interest selected in left and right centrum semioval (CSO) WM. DTI metrics and metabolic contents were significantly altered in MS patients with the exception of N-acetyl-aspartate (NAA) and NAA/Choline (Cho) ratio in RR patients. Significant correlations were observed between diffusion and metabolic measures to various degrees in every MS patients group. Most DTI metrics were significantly correlated with the T2-LL while only NAA/Cr ratio was correlated in RR patients. A comparison analysis of MR methods efficiency demonstrated a better sensitivity/specificity of DTI over MRSI. Nevertheless, NAA/Cr ratio could distinguish all MS and SP patients groups from controls, while NAA/Cho ratio differentiated PP patients from controls. This study demonstrated that diffusivity changes related to microstructural alterations were correlated with metabolic changes and provided a better sensitivity to detect early changes, particularly in RR patients who are more subject to inflammatory processes. In contrast, the better specificity of metabolic ratios to detect axonal damage and demyelination may provide a better index for identification of PP patients. PMID:22479330

  18. Brain structure in narcissistic personality disorder: a VBM and DTI pilot study.

    Science.gov (United States)

    Nenadic, Igor; Güllmar, Daniel; Dietzek, Maren; Langbein, Kerstin; Steinke, Johanna; Gaser, Christian

    2015-02-28

    We analysed T1-weighted MRI scans using voxel-based morphometry (VBM) and tract-based spatial statistics (TBBS) on diffusion tensor images (DTI) in narcissistic personality disorder (NaPD) patients and healthy controls. Grey matter deficits include right prefrontal and bilateral medial prefrontal/anterior cingulate cortices, and decreased fractional anisotropy in right frontal lobe white matter. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Integrating retrogenesis theory to Alzheimer's disease pathology: insight from DTI-TBSS investigation of the white matter microstructural integrity.

    Science.gov (United States)

    Alves, Gilberto Sousa; Oertel Knöchel, Viola; Knöchel, Christian; Carvalho, André Férrer; Pantel, Johannes; Engelhardt, Eliasz; Laks, Jerson

    2015-01-01

    Microstructural abnormalities in white matter (WM) are often reported in Alzheimer's disease (AD) and may reflect primary or secondary circuitry degeneration (i.e., due to cortical atrophy). The interpretation of diffusion tensor imaging (DTI) eigenvectors, known as multiple indices, may provide new insights into the main pathological models supporting primary or secondary patterns of WM disruption in AD, the retrogenesis, and Wallerian degeneration models, respectively. The aim of this review is to analyze the current literature on the contribution of DTI multiple indices to the understanding of AD neuropathology, taking the retrogenesis model as a reference for discussion. A systematic review using MEDLINE, EMBASE, and PUBMED was performed. Evidence suggests that AD evolves through distinct patterns of WM disruption, in which retrogenesis or, alternatively, the Wallerian degeneration may prevail. Distinct patterns of WM atrophy may be influenced by complex interactions which comprise disease status and progression, fiber localization, concurrent risk factors (i.e., vascular disease, gender), and cognitive reserve. The use of DTI multiple indices in addition to other standard multimodal methods in dementia research may help to determine the contribution of retrogenesis hypothesis to the understanding of neuropathological hallmarks that lead to AD.

  20. White Matter Changes in Bipolar Disorder, Alzheimer Disease, and Mild Cognitive Impairment: New Insights from DTI

    Directory of Open Access Journals (Sweden)

    Aikaterini Xekardaki

    2011-01-01

    Full Text Available Neuropathological and neuroimaging studies have reported significant changes in white matter in psychiatric and neurodegenerative diseases. Diffusion tensor imaging (DTI, a recently developed technique, enables the detection of microstructural changes in white matter. It is a noninvasive in vivo technique that assesses water molecules' diffusion in brain tissues. The most commonly used parameters are axial and radial diffusivity reflecting diffusion along and perpendicular to the axons, as well as mean diffusivity and fractional anisotropy representing global diffusion. Although the combination of these parameters provides valuable information about the integrity of brain circuits, their physiological meaning still remains controversial. After reviewing the basic principles of DTI, we report on recent contributions that used this technique to explore subtle structural changes in white matter occurring in elderly patients with bipolar disorder and Alzheimer disease.

  1. DTI studies in patients with Alzheimer's disease, mild cognitive impairment, or normal cognition with evaluation of the intrinsic background gradients

    International Nuclear Information System (INIS)

    Jahng, Geon-Ho; Xu, Songfan; Weiner, Micheal W.; Meyerhoff, Dieter J.; Schuff, Norbert; Park, Seungjoon

    2011-01-01

    The objective of the study was to explore the impact of the background gradients on diffusion tensor (DT) magnetic resonance imaging (DT-MRI) in patients with Alzheimer's disease (AD), mild cognitive impairment (MCI), or cognitively normal (CN) aging. Two DT-MRI sets with positive and negative polarities of the diffusion-sensitizing gradients were obtained in 15 AD patients, 18 MCI patients, and 16 CN control subjects. The maps of mean diffusivity (MD) and fractional anisotropy (FA) were computed separately for positive (p: pMD and pFA) and negative (n: nMD and nFA) polarities, and we computed the geometric mean (gm) of the DT-MRI to obtain the gmFA and gmMD with reducing the background gradient effects. Regional variations were assessed across the groups using one-way analysis of variance. Increased regional gmMD values in the AD subjects, as compared to the regional gmMD values in the MCI and CN subjects, were found primarily in the frontal, limbic, and temporal lobe regions. We also found increased nMD and pMD values in the AD subjects compared to those values in the MCI and CN subjects, including in the temporal lobe and the left limbic parahippocampal gyrus white matter. Results of comparisons among the three methods showed that the left limbic parahippocampal gyrus and right temporal gyrus were the increased MD in the AD patients for all three methods. Background gradients affect the DT-MRI measurements in AD patients. Geometric average diffusion measures can be useful to minimize the intrinsic local magnetic susceptibility variations in brain tissue. (orig.)

  2. A Potential Biomarker in Amyotrophic Lateral Sclerosis: Can Assessment of Brain Iron Deposition with SWI and Corticospinal Tract Degeneration with DTI Help?

    Science.gov (United States)

    Sheelakumari, R; Madhusoodanan, M; Radhakrishnan, A; Ranjith, G; Thomas, B

    2016-02-01

    Iron-mediated oxidative stress plays a pivotal role in the pathogenesis of amyotrophic lateral sclerosis. This study aimed to assess iron deposition qualitatively and quantitatively by using SWI and microstructural changes in the corticospinal tract by using DTI in patients with amyotrophic lateral sclerosis. Seventeen patients with amyotrophic lateral sclerosis and 15 age- and sex-matched controls underwent brain MR imaging with SWI and DTI. SWI was analyzed for both signal-intensity scoring and quantitative estimation of iron deposition in the anterior and posterior banks of the motor and sensory cortices and deep gray nuclei. The diffusion measurements along the corticospinal tract at the level of pons and medulla were obtained by ROI analysis. Patients with amyotrophic lateral sclerosis showed reduced signal-intensity grades in the posterior bank of the motor cortex bilaterally. Quantitative analysis confirmed significantly higher iron content in the posterior bank of the motor cortex in patients with amyotrophic lateral sclerosis. In contrast, no significant differences were noted for the anterior bank of the motor cortex, anterior and posterior banks of the sensory cortex, and deep nuclei. Receiver operating characteristic comparison showed a cutoff of 35μg Fe/g of tissue with an area under the curve of 0.78 (P = .008) for the posterior bank of the motor cortex in discriminating patients with amyotrophic lateral sclerosis from controls. Fractional anisotropy was lower in the pyramidal tracts of patients with amyotrophic lateral sclerosis at the pons and medulla on either side, along with higher directionally averaged mean diffusivity values. The combination of SWI and DTI revealed an area under the curve of 0.784 for differentiating patients with amyotrophic lateral sclerosis from controls. Measurements of motor cortex iron deposition and diffusion tensor parameters of the corticospinal tract may be useful biomarkers for the diagnosis of clinically suspected

  3. Histogram analysis of noise performance on fractional anisotropy brain MR image with different diffusion gradient numbers

    International Nuclear Information System (INIS)

    Chang, Yong Min; Kim, Yong Sun; Kang, Duk Sik; Lee, Young Joo; Sohn, Chul Ho; Woo, Seung Koo; Suh, Kyung Jin

    2005-01-01

    We wished to analyze, qualitatively and quantitatively, the noise performance of fractional anisotropy brain images along with the different diffusion gradient numbers by using the histogram method. Diffusion tensor images were acquired using a 3.0 T MR scanner from ten normal volunteers who had no neurological symptoms. The single-shot spin-echo EPI with a Stejskal-Tanner type diffusion gradient scheme was employed for the diffusion tensor measurement. With a b-valuee of 1000 s/mm 2 , the diffusion tensor images were obtained for 6, 11, 23, 35 and 47 diffusion gradient directions. FA images were generated for each DTI scheme. The histograms were then obtained at selected ROIs for the anatomical structures on the FA image. At the same ROI location, the mean FA value and the standard deviation of the mean FA value were calculated. The quality of the FA image was improved as the number of diffusion gradient directions increased by showing better contrast between the WM and GM. The histogram showed that the variance of FA values was reduced as the number of diffusion gradient directions increased. This histogram analysis was in good agreement with the result obtained using quantitative analysis. The image quality of the FA map was significantly improved as the number of diffusion gradient directions increased. The histogram analysis well demonstrated that the improvement in the FA images resulted from the reduction in the variance of the FA values included in the ROI

  4. Enhancing the Clinical Reasoning Skills of Postgraduate Students in Internal Medicine Through Medical Nonfiction and Nonmedical Fiction Extracurricular Books.

    Science.gov (United States)

    Kiran, H S; Chacko, Thomas V; Murthy, K A Sudharshana; Gowdappa, H Basavana

    2016-12-01

    To improve the clinical reasoning skills of postgraduate students in internal medicine through 2 kinds of extracurricular books: medical nonfiction and nonmedical fiction. Clinical reasoning is difficult to define, understand, observe, teach, and measure. This is an educational innovation under an experimental framework based on a cognitive intervention grounded in constructivist and cognitivist theories. This study was conducted from June 1, 2014, through May 31, 2015. It was a pre-post, randomized, controlled, prospective, mixed-methods, small-group study. The intervention was through medical nonfiction and nonmedical fiction books. The process was structured to ensure that the students would read the material in phases and reflect on them. Clinical reasoning (pretests and posttests) was quantitatively assessed using the Diagnostic Thinking Inventory (DTI) and clinical reasoning exercises (CREs) and their assessment using a rubric. A qualitative design was used, and face-to-face semistructured interviews were conducted. Posttest total scores (DTI=188.92; CREs=53.92) were higher for the study group after the intervention compared with its own pretest scores (DTI=165.25; CREs=41.17) and with the pretest (DTI=159.27; CRE=40.73) and posttest (DTI=166.91; CREs=41.18) scores of the control group. Interviews with the study group confirmed that the intervention was acceptable and useful in daily practice. We introduced, evaluated, and proved an approach to teaching-learning clinical reasoning based on the assumption that the clinical reasoning skills of postgraduate students in internal medicine can be enhanced through 2 kinds of extracurricular books and that fun as well as interest will enhance learning. This study is not only about teaching-learning clinical reasoning but also about the humanities in medical education. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  5. A DTI-based tractography study of effects on brain structure associated with prenatal alcohol exposure in newborns

    Science.gov (United States)

    Taylor, Paul A.; Jacobson, Sandra W.; van der Kouwe, André; Molteno, Christopher D.; Chen, Gang; Wintermark, Pia; Alhamud, Alkathafi; Jacobson, Joseph L.; Meintjes, Ernesta M.

    2014-01-01

    Prenatal alcohol exposure is known to have severe, long-term consequences for brain and behavioral development already detectable in infancy and childhood. Resulting features of fetal alcohol spectrum disorders (FASD) include cognitive and behavioral effects, as well as facial anomalies and growth deficits. Diffusion tensor imaging (DTI) and tractography were used to analyze white matter development in 11 newborns (age since conception <45 weeks) whose mothers were recruited during pregnancy. Comparisons were made with 9 age-matched controls born to abstainers or light drinkers from the same Cape Coloured (mixed ancestry) community near Cape Town, South Africa. DTI parameters, T1 relaxation time, proton density and volumes were used to quantify and investigate group differences in white matter (WM) in the newborn brains. Probabilistic tractography was used to estimate and to delineate similar tract locations among the subjects for transcallosal pathways, cortico-spinal projection fibers and cortico-cortical association fibers. In each of these WM networks, the axial diffusivity AD was the parameter that showed the strongest association with maternal drinking. The strongest relations were observed in medial and inferior WM, regions in which the myelination process typically begins. In contrast to studies of older individuals with prenatal alcohol exposure, FA did not exhibit a consistent and significant relation with alcohol exposure. To our knowledge, this is the first DTI-tractography study of prenatally alcohol exposed newborns. PMID:25182535

  6. Demyelinating evidences in CMS rat model of depression: a DTI study at 7 T.

    Science.gov (United States)

    Hemanth Kumar, B S; Mishra, S K; Trivedi, R; Singh, S; Rana, P; Khushu, S

    2014-09-05

    Depression is among the most debilitating diseases worldwide. Long-term exposure to stressors plays a major role in development of human depression. Chronic mild stress (CMS) seems to be a valid animal model for depression. Diffusion tensor imaging (DTI) is capable of inferring microstructural abnormalities of the white matter and has shown to serve as non-invasive marker of specific pathology. We developed a CMS rat model of depression and validated with behavioral experiments. We measured the diffusion indices (mean diffusivity (MD), fractional anisotropy (FA), axial (λ∥) and radial (λ⊥) diffusivity) to investigate the changes in CMS rat brain during depression onset. Diffusion indices have shown to be useful to discriminate myelin damage from axon loss. DTI was performed in both control and CMS rats (n=10, in each group) and maps of FA, MD, λ∥ and λ⊥ diffusivity values were generated using in-house built software. The diffusion indices were calculated by region of interest (ROI) analysis in different brain regions like the frontal cortex, hippocampus, hypothalamus, cingulum, thalamus, caudate putamen, corpus callosum, cerebral peduncle and sensory motor cortex. The results showed signs of demyelination, reflected by increased MD, decreased FA and increased λ⊥. The results also suggest a possible role of edema or inflammation concerning the brain morphology in CMS rats. The overall finding using DTI suggests there might be a major role of loss of myelin sheath, which leads to disrupted connectivity between the limbic area and the prefrontal cortex during the onset of depression. Our findings indicate that interpretation of these indices may provide crucial information about the type and severity of mood disorders. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  7. Magnetic resonance imaging DTI-FT study on schizophrenic patients with typical negative first symptoms.

    Science.gov (United States)

    Gu, Chengyu; Zhang, Ying; Wei, Fuquan; Cheng, Yougen; Cao, Yulin; Hou, Hongtao

    2016-09-01

    Magnetic resonance imaging (MRI) with diffusion-tensor imaging (DTI) together with a white matter fiber tracking (FT) technique was used to assess different brain white matter structures and functionalities in schizophrenic patients with typical first negative symptoms. In total, 30 schizophrenic patients with typical first negative symptoms, comprising an observation group were paired 1:1 according to gender, age, right-handedness, and education, with 30 healthy individuals in a control group. Individuals in each group underwent routine MRI and DTI examination of the brain, and diffusion-tensor tractography (DTT) data were obtained through whole brain analysis based on voxel and tractography. The results were expressed by fractional anisotropy (FA) values. The schizophrenic patients were evaluated using a positive and negative symptom scale (PANSS) as well as a Global Assessment Scale (GAS). The results of the study showed that routine MRIs identified no differences between the two groups. However, compared with the control group, the FA values obtained by DTT from the deep left prefrontal cortex, the right deep temporal lobe, the white matter of the inferior frontal gyrus and part of the corpus callosum were significantly lower in the observation group (Pscale value in the observation group averaged 7.7±1.5, and the negative scale averaged 46.6±5.9, while the general psychopathology scale averaged 65.4±10.3, and GAS averaged 53.8±19.2. The Pearson statistical analysis, the left deep prefrontal cortex, the right deep temporal lobe, the white matter of the inferior frontal gyrus and the FA value of part of the corpus callosum in the observation group was negatively correlated with the negative scale (Pnegative symptoms and the application of MRI DTI-FT can improve diagnostic accuracy.

  8. Structural brain alterations in bipolar disorder II: a combined voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) study.

    Science.gov (United States)

    Ambrosi, Elisa; Rossi-Espagnet, Maria Camilla; Kotzalidis, Georgios D; Comparelli, Anna; Del Casale, Antonio; Carducci, Filippo; Romano, Andrea; Manfredi, Giovanni; Tatarelli, Roberto; Bozzao, Alessandro; Girardi, Paolo

    2013-09-05

    Brain structural changes have been described in bipolar disorder (BP), but usually studies focused on both I and II subtypes indiscriminately and investigated changes in either brain volume or white matter (WM) integrity. We used combined voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) analysis to track changes in the grey matter (GM) and WM in the brains of patients affected by BPII, as compared to healthy controls. Using VBM and DTI, we scanned 20 DSM-IV-TR BPII patients in their euthymic phase and 21 healthy, age- and gender-matched volunteers with no psychiatric history. VBM showed decreases in GM of BPII patients, compared to controls, which were diffuse in nature and most prominent in the right middle frontal gyrus and in the right superior temporal gurus. DTI showed significant and widespread FA reduction in BPII patients in all major WM tracts, including cortico-cortical association tracts. The small sample size limits the generalisability of our findings. Reduced GM volumes and WM integrity changes in BPII patients are not prominent like those previously reported in bipolar disorder type-I and involve cortical structures and their related association tracts. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Surgical outcome of motor deficits and neurological status in brainstem cavernous malformations based on preoperative diffusion tensor imaging: a prospective randomized clinical trial.

    Science.gov (United States)

    Li, Da; Jiao, Yu-Ming; Wang, Liang; Lin, Fu-Xin; Wu, Jun; Tong, Xian-Zeng; Wang, Shuo; Cao, Yong

    2018-03-16

    OBJECTIVE Surgical management of brainstem lesions is challenging due to the highly compact, eloquent anatomy of the brainstem. This study aimed to evaluate the safety and efficacy of preoperative diffusion tensor imaging (DTI) and diffusion tensor tractography (DTT) in brainstem cavernous malformations (CMs). METHODS A prospective randomized controlled clinical trial was performed by using stratified blocked randomization. The primary eligibility criterion of the study was being a surgical candidate for brainstem CMs (with informed consent). The study enrolled 23 patients who underwent preoperative DTI/DTT and 24 patients who did not (the control group). The pre- and postoperative muscle strength of both limbs and modified Rankin Scale (mRS) scores were evaluated. Muscle strength of any limb at 12 months after surgery at the clinic visit was the primary outcome; worsened muscle strength was considered to be a poor outcome. Outcome assessors were blinded to patient management. This study reports the preliminary results of the interim analysis. RESULTS The cohort included 47 patients (22 women) with a mean age of 35.7 years. The clinical baselines between these 2 groups were not significantly different. In the DTI/DTT group, the corticospinal tract was affected in 17 patients (73.9%): it was displaced, deformed/partially interrupted, or completely interrupted in 6, 7, and 4 patients, respectively. The surgical approach and brainstem entry point were adjusted in 3 patients (13.0%) based on DTI/DTT data. The surgical morbidity of the DTI/DTT group (7/23, 30.4%) was significantly lower than that of the control group (19/24, 79.2%, p = 0.001). At 12 months, the mean mRS score (1.1, p = 0.034) and percentage of patients with worsened motor deficits (4.3%, p = 0.006) were significantly lower in the DTI/DTT group than in the control group (1.7% and 37.5%). Multivariate logistic regression identified the absence of preoperative DTI/DTT (OR 0.06, 95% CI 0.01-0.73, p = 0

  10. A DTI study to probe tumor microstructure and its connection with hypoxia.

    Science.gov (United States)

    Majumdar, Shreyan; Kotecha, Mrignayani; Triplett, William; Epel, Boris; Halpern, Howard

    2014-01-01

    Solid tumors have chaotic organization of blood vessels, disruptive nerve paths and muscle fibers that result in a hostile and heterogeneous microenvironment. These tumor regions are often hypoxic and resistant to radiation therapy. The knowledge of partial pressure of oxygen concentration (pO2), in conjunction with the information about tissue organization, can predict tissue health and may eventually be used in combination with intensity-modulated radiation therapy (IMRT) for targeted destruction of radiation-resistant areas, while sparing healthy tissues. Diffusion tensor imaging (DTI) based parameter fractional anisotropy (FA) can be used to assess organization of tissue microstructure, whereas the pO2 can be measured using electron paramagnetic resonance oxygen imaging (EPROI). This study is our first step to connect these two important physiological parameters. We calculated FA in fixed fibrosarcoma (FSa) grown in hind leg of nude mice (n = 6) using preclinical 9.4 T MRI. The FA in tumor region (0.34 ± 0.014) was found to be lower when compared to normal surrounding region (0.36 ± 0.013). We hypothesized that the change in FA is directly correlated with the change in oxygen concentration in tumor. We present preliminary in vivo results showing a positive correlation (R = 0.85, p = 0.017) between the FA and pO2 values acquired for MCa4 tumor (n = 1) using DTI and EPROI.

  11. Microstructural Changes in Compressed Nerve Roots Are Consistent With Clinical Symptoms and Symptom Duration in Patients With Lumbar Disc Herniation.

    Science.gov (United States)

    Wu, Weifei; Liang, Jie; Ru, Neng; Zhou, Caisheng; Chen, Jianfeng; Wu, Yongde; Yang, Zong

    2016-06-01

    A prospective study. To investigate the association between microstructural nerve roots changes on diffusion tensor imaging (DTI) and clinical symptoms and their duration in patients with lumbar disc herniation. The ability to identify microstructural properties of the nervous system with DTI has been demonstrated in many studies. However, there are no data regarding the association between microstructural changes evaluated using DTI and symptoms assessed with the Oswestry Disability Index (ODI) and their duration. Forty consecutive patients with foraminal disc herniation affecting unilateral sacral 1 (S1) nerve roots were enrolled in this study. DTI with tractography was performed on the S1 nerve roots. Clinical symptoms were evaluated using an ODI questionnaire for each patient, and the duration of clinical symptoms was noted based on the earliest instance of leg pain and numbness. Mean fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values were calculated from tractography images. The mean FA value of the compressed lumbar nerve roots was significantly lower than the FA of the contralateral nerve roots (P leg pain, indicating that the microstructure of the nerve root has been damaged. 3.

  12. Pre-surgical integration of FMRI and DTI of the sensorimotor system in transcortical resection of a high-grade insular astrocytoma

    Directory of Open Access Journals (Sweden)

    Chelsea eEkstrand

    2016-03-01

    Full Text Available Herein we report on a patient with a WHO Grade III astrocytoma in the right insular region in close proximity to the internal capsule who underwent a right frontotemporal craniotomy. Total gross resection of insular gliomas remains surgically challenging based on the possibility of damage to the corticospinal tracts. However, maximizing the extent of resection has been shown to decrease future adverse outcomes. Thus, the goal of such surgeries should focus on maximizing extent of resection while minimizing possible adverse outcomes. In this case, pre-surgical planning included integration of functional magnetic resonance imaging (fMRI and diffusion tensor imaging (DTI, to localize motor and sensory pathways. Novel fMRI tasks were individually developed for the patient to maximize both somatosensory and motor activation simultaneously in areas in close proximity to the tumor. Information obtained was used to optimize resection trajectory and extent, facilitating gross total resection of the astrocytoma. Across all three motor-sensory tasks administered, fMRI revealed an area of interest just superior and lateral to the astrocytoma. Further, DTI analyses showed displacement of the corona radiata around the superior dorsal surface of the astrocytoma, extending in the direction of the activation found using fMRI. Taking into account these results, a transcortical superior temporal gyrus surgical approach was chosen in order to avoid the area of interest identified by fMRI and DTI. Total gross resection was achieved and minor post-surgical motor and sensory deficits were temporary. This case highlights the utility of comprehensive pre-surgical planning, including fMRI and DTI, to maximize surgical outcomes on a case-by-case basis.

  13. Functional imaging for brain tumors (perfusion, DTI and MR spectroscopy)

    International Nuclear Information System (INIS)

    Essig, M.; Giesel, F.; Stieltjes, B.; Weber, M.A.

    2007-01-01

    This contribution considers the possibilities involved with using functional methods in magnetic resonance imaging (MRI) diagnostics for brain tumors. Of the functional methods available, we discuss perfusion MRI (PWI), diffusion MRI (DWI and DTI) and MR spectroscopy (H-MRS). In cases of brain tumor, PWI aids in grading and better differentiation in diagnostics as well as for pre-therapeutic planning. In addition, the course of treatment, both after chemo- as well as radiotherapy in combination with surgical treatment, can be optimized. PWI allows better estimates of biological activity and aggressiveness in low grade brain tumors, and in the case of WHO grade II astrocytoma showing anaplastically transformed tumor areas, allows more rapid visualization and a better prediction of the course of the disease than conventional MRI diagnostics. Diffusion MRI, due to the directional dependence of the diffusion, can illustrate the course and direction of the nerve fibers, as well as reconstructing the nerve tracts in the cerebrum, pons and cerebellum 3-dimensionally. Diffusion imaging can be used for describing brain tumors, for evaluating contralateral involvement and the course of the nerve fibers near the tumor. Due to its operator dependence, DTI based fiber tracking for defining risk structures is controversial. DWI can also not differentiate accurately between cystic and necrotic brain tumors, or between metastases and brain abscesses. H-MRS provides information on cell membrane metabolism, neuronal integrity and the function of neuronal structures, energy metabolism and the formation of tumors and brain tissue necroses. Diagnostic problems such as the differentiation between neoplastic and non-neoplastic lesions, grading cerebral glioma and distinguishing between primary brain tumors and metastases can be resolved. An additional contribution will discuss the control of the course of glial tumors after radiotherapy. (orig.)

  14. Effect of increasing diffusion gradient direction number on diffusion tensor imaging fiber tracking in the human brain

    International Nuclear Information System (INIS)

    Yao, Xu Fang; Liang, Bie Bei; Xia, Tian; Huang, Qin Ming; Zhuang, Song Lin; Yu, Tong Gang

    2015-01-01

    To assess the effects of varying the number of diffusion gradient directions (NDGDs) on diffusion tensor fiber tracking (FT) in human brain white matter using tract characteristics. Twelve normal volunteers underwent diffusion tensor imaging (DTI) scanning with NDGDs of 6, 11, 15, 21, and 31 orientations. Three fiber tract groups, including the splenium of the corpus callosum (CC), the entire CC, and the full brain tract, were reconstructed by deterministic DTI-FT. Tract architecture was first qualitatively evaluated by visual observation. Six quantitative tract characteristics, including the number of fibers (NF), average length (AL), fractional anisotropy (FA), relative anisotropy (RA), mean diffusivity (MD), and volume ratio (VR) were measured for the splenium of the CC at the tract branch level, for the entire CC at tract level, and for the full brain tract at the whole brain level. Visual results and those of NF, AL, FA, RA, MD, and VR were compared among the five different NDGDs. The DTI-FT with NDGD of 11, 15, 21, and 31 orientations gave better tracking results compared with NDGD of 6 after the visual evaluation. NF, FA, RA, MD, and VR values with NDGD of six were significantly greater (smallest p = 0.001 to largest p = 0.042) than those with four other NDGDs (11, 15, 21, or 31 orientations), whereas AL measured with NDGD of six was significantly smaller (smallest p = 0.001 to largest p = 0.041) than with four other NDGDs (11, 15, 21, or 31 orientations). No significant differences were observed in the results among the four NDGD groups of 11, 15, 21, and 31 directions (smallest p = 0.059 to largest p = 1.000). The main fiber tracts were detected with NDGD of six orientations; however, the use of larger NDGD (> or = 11 orientations) could provide improved tract characteristics at the expense of longer scanning time.

  15. Effect of increasing diffusion gradient direction number on diffusion tensor imaging fiber tracking in the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Xu Fang; Liang, Bie Bei; Xia, Tian; Huang, Qin Ming; Zhuang, Song Lin [School of Optical-Electrical and Computer Engineering, Shanghai Medical Instrument College, University of Shanghai for Science and Technology, Shanghai (China); Yu, Tong Gang [Dept. of Radiology, Huashan Hospital, Fudan University, Shanghai (China)

    2015-04-15

    To assess the effects of varying the number of diffusion gradient directions (NDGDs) on diffusion tensor fiber tracking (FT) in human brain white matter using tract characteristics. Twelve normal volunteers underwent diffusion tensor imaging (DTI) scanning with NDGDs of 6, 11, 15, 21, and 31 orientations. Three fiber tract groups, including the splenium of the corpus callosum (CC), the entire CC, and the full brain tract, were reconstructed by deterministic DTI-FT. Tract architecture was first qualitatively evaluated by visual observation. Six quantitative tract characteristics, including the number of fibers (NF), average length (AL), fractional anisotropy (FA), relative anisotropy (RA), mean diffusivity (MD), and volume ratio (VR) were measured for the splenium of the CC at the tract branch level, for the entire CC at tract level, and for the full brain tract at the whole brain level. Visual results and those of NF, AL, FA, RA, MD, and VR were compared among the five different NDGDs. The DTI-FT with NDGD of 11, 15, 21, and 31 orientations gave better tracking results compared with NDGD of 6 after the visual evaluation. NF, FA, RA, MD, and VR values with NDGD of six were significantly greater (smallest p = 0.001 to largest p = 0.042) than those with four other NDGDs (11, 15, 21, or 31 orientations), whereas AL measured with NDGD of six was significantly smaller (smallest p = 0.001 to largest p = 0.041) than with four other NDGDs (11, 15, 21, or 31 orientations). No significant differences were observed in the results among the four NDGD groups of 11, 15, 21, and 31 directions (smallest p = 0.059 to largest p = 1.000). The main fiber tracts were detected with NDGD of six orientations; however, the use of larger NDGD (> or = 11 orientations) could provide improved tract characteristics at the expense of longer scanning time.

  16. The Value of Neurosurgical and Intraoperative Magnetic Resonance Imaging and Diffusion Tensor Imaging Tractography in Clinically Integrated Neuroanatomy Modules: A Cross-Sectional Study

    Science.gov (United States)

    Familiari, Giuseppe; Relucenti, Michela; Heyn, Rosemarie; Baldini, Rossella; D'Andrea, Giancarlo; Familiari, Pietro; Bozzao, Alessandro; Raco, Antonino

    2013-01-01

    Neuroanatomy is considered to be one of the most difficult anatomical subjects for students. To provide motivation and improve learning outcomes in this area, clinical cases and neurosurgical images from diffusion tensor imaging (DTI) tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI) were presented and…

  17. The effects of mild germinal matrix-intraventricular haemorrhage on the developmental white matter microstructure of preterm neonates. A DTI study

    International Nuclear Information System (INIS)

    Tortora, Domenico; Martinetti, Carola; Severino, Mariasavina; Morana, Giovanni; Rossi, Andrea; Uccella, Sara; Brera, Fabia; Malova, Mariya; Parodi, Alessandro; Ramenghi, Luca Antonio

    2018-01-01

    To evaluate white matter (WM) microstructural changes in preterm neonates (PN) with mild germinal matrix-intraventricular haemorrhage (mGMH-IVH) (grades I and II) and no other associated MRI abnormalities, and correlate them with gestational age (GA) and neurodevelopmental outcome. Tract-based spatial-statistics (TBSS) was performed on DTI of 103 patients studied at term-equivalent age, to compare diffusional parameters (fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD), axial diffusivity (AD)) between mGMH-IVH neonates (24/103) and controls matched by GA at birth and sex. The relationship between DTI abnormalities, GA and neurodevelopmental outcome assessed with Griffiths' Developmental Scale-Revised:0-2 was explored using TBSS and Spearman-correlation analysis (p <.05). Affected neonates had lower FA, higher RD and MD of the corpus callosum, limbic pathways and cerebellar tracts. Extremely preterm neonates (GA < 29 weeks) presented more severe microstructural impairment (higher RD and MD) in periventricular regions. Neonates of GA ≥ 29 weeks had milder WM alterations (lower FA), also in subcortical WM. DTI abnormalities were associated with poorer locomotor, eye-hand coordination and performance outcomes at 24 months. WM microstructural changes occur in PN with mGMH-IVH with a GA-dependent selective vulnerability of WM regions, and correlate with adverse neurodevelopmental outcome at 24 months. (orig.)

  18. The effects of mild germinal matrix-intraventricular haemorrhage on the developmental white matter microstructure of preterm neonates. A DTI study

    Energy Technology Data Exchange (ETDEWEB)

    Tortora, Domenico; Martinetti, Carola; Severino, Mariasavina; Morana, Giovanni; Rossi, Andrea [Istituto Giannina Gaslini, Neuroradiology Unit, Genoa (Italy); Uccella, Sara; Brera, Fabia [Istituto Giannina Gaslini, Neuropsychiatry Unit, Genoa (Italy); Malova, Mariya; Parodi, Alessandro; Ramenghi, Luca Antonio [Istituto Giannina Gaslini, Neonatal Intensive Care Unit, Genoa (Italy)

    2018-03-15

    To evaluate white matter (WM) microstructural changes in preterm neonates (PN) with mild germinal matrix-intraventricular haemorrhage (mGMH-IVH) (grades I and II) and no other associated MRI abnormalities, and correlate them with gestational age (GA) and neurodevelopmental outcome. Tract-based spatial-statistics (TBSS) was performed on DTI of 103 patients studied at term-equivalent age, to compare diffusional parameters (fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD), axial diffusivity (AD)) between mGMH-IVH neonates (24/103) and controls matched by GA at birth and sex. The relationship between DTI abnormalities, GA and neurodevelopmental outcome assessed with Griffiths' Developmental Scale-Revised:0-2 was explored using TBSS and Spearman-correlation analysis (p <.05). Affected neonates had lower FA, higher RD and MD of the corpus callosum, limbic pathways and cerebellar tracts. Extremely preterm neonates (GA < 29 weeks) presented more severe microstructural impairment (higher RD and MD) in periventricular regions. Neonates of GA ≥ 29 weeks had milder WM alterations (lower FA), also in subcortical WM. DTI abnormalities were associated with poorer locomotor, eye-hand coordination and performance outcomes at 24 months. WM microstructural changes occur in PN with mGMH-IVH with a GA-dependent selective vulnerability of WM regions, and correlate with adverse neurodevelopmental outcome at 24 months. (orig.)

  19. DTI studies in patients with Alzheimer's disease, mild cognitive impairment, or normal cognition with evaluation of the intrinsic background gradients

    Energy Technology Data Exchange (ETDEWEB)

    Jahng, Geon-Ho [Kyung Hee University, Department of Radiology, Kyung Hee University Hospital-Gangdong, School of Medicine, Seoul (Korea, Republic of); Xu, Songfan [Graduate School of Kyung Hee University, Department of Biomedical Science, Seoul (Korea, Republic of); Weiner, Micheal W.; Meyerhoff, Dieter J.; Schuff, Norbert [University of California-San Francisco, Center for Imaging of Neurodegenerative Diseases, VA Medical Center and the Department of Radiology, San Francisco, CA (United States); Park, Seungjoon [Graduate School of Kyung Hee University, Department of Biomedical Science, Seoul (Korea, Republic of); Kyung Hee University, Department of Pharmacology and the Medical Research Center for Bioreaction to ROS and the Biomedical Science Institute, School of Medicine, Seoul (Korea, Republic of)

    2011-10-15

    The objective of the study was to explore the impact of the background gradients on diffusion tensor (DT) magnetic resonance imaging (DT-MRI) in patients with Alzheimer's disease (AD), mild cognitive impairment (MCI), or cognitively normal (CN) aging. Two DT-MRI sets with positive and negative polarities of the diffusion-sensitizing gradients were obtained in 15 AD patients, 18 MCI patients, and 16 CN control subjects. The maps of mean diffusivity (MD) and fractional anisotropy (FA) were computed separately for positive (p: pMD and pFA) and negative (n: nMD and nFA) polarities, and we computed the geometric mean (gm) of the DT-MRI to obtain the gmFA and gmMD with reducing the background gradient effects. Regional variations were assessed across the groups using one-way analysis of variance. Increased regional gmMD values in the AD subjects, as compared to the regional gmMD values in the MCI and CN subjects, were found primarily in the frontal, limbic, and temporal lobe regions. We also found increased nMD and pMD values in the AD subjects compared to those values in the MCI and CN subjects, including in the temporal lobe and the left limbic parahippocampal gyrus white matter. Results of comparisons among the three methods showed that the left limbic parahippocampal gyrus and right temporal gyrus were the increased MD in the AD patients for all three methods. Background gradients affect the DT-MRI measurements in AD patients. Geometric average diffusion measures can be useful to minimize the intrinsic local magnetic susceptibility variations in brain tissue. (orig.)

  20. Diffusion tensor imaging during recovery from severe traumatic brain injury and relation to clinical outcome: A longitudinal study

    DEFF Research Database (Denmark)

    Sidaros, A.; Engberg, A.W.; Sidaros, K.

    2008-01-01

    of longitudinal studies on TBI that follow DTI changes over time and correlate findings with long-term clinical outcome. We performed a prospective longitudinal study of 30 adult patients admitted for subacute rehabilitation following severe traumatic brain injury. DTI and conventional MRI were acquired at mean 8......Diffusion tensor imaging (DTI) has been proposed as a sensitive biomarker of traumatic white matter injury, which could potentially serve as a tool for prognostic assessment and for studying microstructural changes during recovery from traumatic brain injury (TBI). However, there is a lack...... weeks (5-11 weeks), and repeated in 23 of the patients at mean 12 months (9-15 months) post-trauma. Using a region-of-interest-based approach, DTI parameters were compared to those of healthy matched controls, scanned during the same time period and rescanned with a similar interval as that of patients...

  1. Assessment of brain maturation in the preterm infants using diffusion tensor imaging (DTI) and enhanced T2 star weighted angiography (ESWAN)

    International Nuclear Information System (INIS)

    Ling, Xueying; Tang, Wen; Liu, Guosheng; Huang, Li; Li, Bingxiao; Li, Xiaofei; Liu, Sirun; Xu, Jing

    2013-01-01

    Purpose: To assess the brain maturation of preterm infants using diffusion tensor imaging (DTI) and enhanced T2 star weighted angiography (ESWAN). Materials and methods: Conventional magnetic resonance imaging (MRI), DTI and ESWAN were performed in 60 preterm infants and 21 term controls. 60 preterm infants were subgrouped to two groups according to the age at imaging: before and at term-equivalent age (TEA). Fractional anisotropy (FA), apparent diffusion coefficient (ADC) map from DTI, T 2 * and R 2 * maps from ESWAN were post-processed at an off-line workstation. The values of FA, ADC, T 2 * and R 2 * from the posterior limb of internal capsule (PLIC), frontal white matter (FWM), occipital white matter (OWM) and lentiform nuclei (LN) were determined. These parameters were compared between preterm and term infants. Correlations of DTI and ESWAN parameters with the gestational age, postmenstrual age and postnatal age were analyzed. Results: ADCs of FWM, OWM and LN, and T 2 * values of the PLIC and LN were higher in the preterm infants at TEA compared with the term controls. The correlations were existed between the postmenstrual age and the values of FA, ADC, T 2 *, R 2 * from the PLIC, values of ADC, T 2 *, R 2 * from the LN, T 2 * value from the OWM. The correlations were also found between the postnatal age and the values of FA, ADC, T 2 * from the PLIC, and T 2 * value from the LN. Conclusion: The maturity of preterm brain around TEA was different from that of term controls and appeared to be independent of the prematurity at birth. T 2 * was one of valuable indices to evaluate brain maturation in preterm infants

  2. Assessment of brain maturation in the preterm infants using diffusion tensor imaging (DTI) and enhanced T2 star weighted angiography (ESWAN)

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Xueying, E-mail: lingxuey@163.com [Department of Medical Imaging Center, the First Affiliated Hospital, Jinan University, Guangzhou (China); Tang, Wen [Department of Medical Imaging Center, the First Affiliated Hospital, Jinan University, Guangzhou (China); Liu, Guosheng [Neonatal Intensive Care Unit, the First Affiliated Hospital, Jinan University, Guangzhou (China); Huang, Li [Department of Medical Imaging Center, the First Affiliated Hospital, Jinan University, Guangzhou (China); Li, Bingxiao [Neonatal Intensive Care Unit, the First Affiliated Hospital, Jinan University, Guangzhou (China); Li, Xiaofei; Liu, Sirun [Department of Medical Imaging Center, the First Affiliated Hospital, Jinan University, Guangzhou (China); Xu, Jing [Neonatal Intensive Care Unit, the First Affiliated Hospital, Jinan University, Guangzhou (China)

    2013-09-15

    Purpose: To assess the brain maturation of preterm infants using diffusion tensor imaging (DTI) and enhanced T2 star weighted angiography (ESWAN). Materials and methods: Conventional magnetic resonance imaging (MRI), DTI and ESWAN were performed in 60 preterm infants and 21 term controls. 60 preterm infants were subgrouped to two groups according to the age at imaging: before and at term-equivalent age (TEA). Fractional anisotropy (FA), apparent diffusion coefficient (ADC) map from DTI, T{sub 2}* and R{sub 2}* maps from ESWAN were post-processed at an off-line workstation. The values of FA, ADC, T{sub 2}* and R{sub 2}* from the posterior limb of internal capsule (PLIC), frontal white matter (FWM), occipital white matter (OWM) and lentiform nuclei (LN) were determined. These parameters were compared between preterm and term infants. Correlations of DTI and ESWAN parameters with the gestational age, postmenstrual age and postnatal age were analyzed. Results: ADCs of FWM, OWM and LN, and T{sub 2}* values of the PLIC and LN were higher in the preterm infants at TEA compared with the term controls. The correlations were existed between the postmenstrual age and the values of FA, ADC, T{sub 2}*, R{sub 2}* from the PLIC, values of ADC, T{sub 2}*, R{sub 2}* from the LN, T{sub 2}* value from the OWM. The correlations were also found between the postnatal age and the values of FA, ADC, T{sub 2}* from the PLIC, and T{sub 2}* value from the LN. Conclusion: The maturity of preterm brain around TEA was different from that of term controls and appeared to be independent of the prematurity at birth. T{sub 2}* was one of valuable indices to evaluate brain maturation in preterm infants.

  3. Structural MRI research in patients with nasopharyngeal carcinoma following radiotherapy: A DTI and VBM study.

    Science.gov (United States)

    Leng, Xi; Fang, Peng; Lin, Huan; An, Jie; Tan, Xin; Zhang, Chi; Wu, Donglin; Shen, Wen; Qiu, Shijun

    2017-11-01

    The aim of the present study was to investigate the microstructural characteristics of the brain lobes following radiotherapy (RT) for patients with nasopharyngeal carcinoma (NPC) at distinct times. Diffusion tensor imaging (DTI) and 3D-T1-weighted imaging was performed in 70 age- and sex-matched subjects, 24 of whom were pre-treatment patients. The patients were divided into three groups, according to the time following completion of RT. Fractional anisotropy (FA) and gray matter (GM) volume were determined. The DTI data were analyzed using tract-based spatial statistics and the GM volume was analyzed using voxel-based morphometry (VBM). Compared with the pre-RT group, the mean FA values in the left parietal lobe white matter (WM) and right cerebellum decreased significantly in the post-RT 0-6 month group (P<0.05). In addition, the mean FA values in the right parietal lobe WM decreased significantly in the post-RT 6-12 month group (P<0.05), compared with the pre-RT group. The FA level in the right temporal lobe remained significantly decreased, compared with that in the pre-RT group (P<0.05) for 1 year after RT. Furthermore, compared with pre-RT group, the GM volume in the bilateral frontal lobe, right occipital lobe, left parietal lobe, right temporal lobe and left cerebellum decreased significantly in the post-RT 0-6 month group (P<0.05), and in the bilateral temporal lobe, parietal lobe, right frontal lobe and left cerebellum, the GM volume decreased significantly in the post-RT 6-12 month group (P<0.05). The GM volume in the right temporal lobe, bilateral frontal lobe and bilateral cerebellum remained significantly decreased compared with that in the pre-RT group (P<0.05) for 1 year after RT. A combination of DTI and VBM may be used to determine radiation-induced brain injury in patients treated for NPC.

  4. Visualizing whole-brain DTI tractography with GPU-based Tuboids and LoD management.

    Science.gov (United States)

    Petrovic, Vid; Fallon, James; Kuester, Falko

    2007-01-01

    Diffusion Tensor Imaging (DTI) of the human brain, coupled with tractography techniques, enable the extraction of large-collections of three-dimensional tract pathways per subject. These pathways and pathway bundles represent the connectivity between different brain regions and are critical for the understanding of brain related diseases. A flexible and efficient GPU-based rendering technique for DTI tractography data is presented that addresses common performance bottlenecks and image-quality issues, allowing interactive render rates to be achieved on commodity hardware. An occlusion query-based pathway LoD management system for streamlines/streamtubes/tuboids is introduced that optimizes input geometry, vertex processing, and fragment processing loads, and helps reduce overdraw. The tuboid, a fully-shaded streamtube impostor constructed entirely on the GPU from streamline vertices, is also introduced. Unlike full streamtubes and other impostor constructs, tuboids require little to no preprocessing or extra space over the original streamline data. The supported fragment processing levels of detail range from texture-based draft shading to full raycast normal computation, Phong shading, environment mapping, and curvature-correct text labeling. The presented text labeling technique for tuboids provides adaptive, aesthetically pleasing labels that appear attached to the surface of the tubes. Furthermore, an occlusion query aggregating and scheduling scheme for tuboids is described that reduces the query overhead. Results for a tractography dataset are presented, and demonstrate that LoD-managed tuboids offer benefits over traditional streamtubes both in performance and appearance.

  5. Cerebral asymmetry in patients with schizophrenia: a voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) study.

    Science.gov (United States)

    Takao, Hidemasa; Abe, Osamu; Yamasue, Hidenori; Aoki, Shigeki; Kasai, Kiyoto; Ohtomo, Kuni

    2010-01-01

    To evaluate the differences in gray- and white-matter asymmetry between schizophrenia patients and normal subjects. Forty-eight right-handed patients with chronic schizophrenia (24 males and 24 females) and 48 right-handed age- and sex-matched healthy controls (24 males and 24 females) were included in this study. The effects of diagnosis on gray-matter volume asymmetry and white-matter fractional anisotropy (FA) asymmetry were evaluated with use of voxel-based morphometry (VBM) and voxel-based analysis of FA maps derived from diffusion tensor imaging (DTI), respectively. The mean gray- and white-matter volumes were significantly smaller in the schizophrenia group than in the control group. The voxel-based morphometry (VBM) showed no significant effect of diagnosis on gray-matter volume asymmetry. The voxel-based analysis of DTI also showed no significant effect of diagnosis on white-matter FA asymmetry. Our results of voxel-based analyses showed no significant differences in either gray-matter volume asymmetry or white-matter FA asymmetry between schizophrenia patients and normal subjects. (c) 2009 Wiley-Liss, Inc.

  6. Rat brain digital stereotaxic white matter atlas with fine tract delineation in Paxinos space and its automated applications in DTI data analysis.

    Science.gov (United States)

    Liang, Shengxiang; Wu, Shang; Huang, Qi; Duan, Shaofeng; Liu, Hua; Li, Yuxiao; Zhao, Shujun; Nie, Binbin; Shan, Baoci

    2017-11-01

    To automatically analyze diffusion tensor images of the rat brain via both voxel-based and ROI-based approaches, we constructed a new white matter atlas of the rat brain with fine tracts delineation in the Paxinos and Watson space. Unlike in previous studies, we constructed a digital atlas image from the latest edition of the Paxinos and Watson. This atlas contains 111 carefully delineated white matter fibers. A white matter network of rat brain based on anatomy was constructed by locating the intersection of all these tracts and recording the nuclei on the pathway of each white matter tract. Moreover, a compatible rat brain template from DTI images was created and standardized into the atlas space. To evaluate the automated application of the atlas in DTI data analysis, a group of rats with right-side middle cerebral artery occlusion (MCAO) and those without were enrolled in this study. The voxel-based analysis result shows that the brain region showing significant declines in signal in the MCAO rats was consistent with the occlusion position. We constructed a stereotaxic white matter atlas of the rat brain with fine tract delineation and a compatible template for the data analysis of DTI images of the rat brain. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Integration of BOLD-fMRI and DTI into radiation treatment planning for high-grade gliomas located near the primary motor cortexes and corticospinal tracts

    International Nuclear Information System (INIS)

    Wang, Minglei; Ma, Hui; Wang, Xiaodong; Guo, Yanhong; Xia, Xinshe; Xia, Hechun; Guo, Yulin; Huang, Xueying; He, Hong; Jia, Xiaoxiong; Xie, Yan

    2015-01-01

    The main objective of this study was to evaluate the efficacy of integrating the blood oxygen level dependent functional magnetic resonance imaging (BOLD-fMRI) and diffusion tensor imaging (DTI) data into radiation treatment planning for high-grade gliomas located near the primary motor cortexes (PMCs) and corticospinal tracts (CSTs). A total of 20 patients with high-grade gliomas adjacent to PMCs and CSTs between 2012 and 2014 were recruited. The bilateral PMCs and CSTs were located in the normal regions without any overlapping with target volume of the lesions. BOLD-fMRI, DTI and conventional MRI were performed on patients (Karnofsky performance score ≥ 70) before radical radiotherapy treatment. Four different imaging studies were conducted in each patient: a planning computed tomography (CT), an anatomical MRI, a DTI and a BOLD-fMRI. For each case, three treatment plans (3DCRT, IMRT and IMRT-PMC&CST) were developed by 3 different physicists using the Pinnacle planning system. Our study has shown that there was no significant difference between the 3DCRT and IMRT plans in terms of dose homogeneity, but IMRT displayed better planning target volume (PTV) dose conformity. In addition, we have found that the Dmax and Dmean to the ipsilateral and contralateral PMC and CST regions were considerably decreased in IMRT-PMC&CST group (p < 0.001). In conclusion, integration of BOLD-fMRI and DTI into radiation treatment planning is feasible and beneficial. With the assistance of the above-described techniques, the bilateral PMCs and CSTs adjacent to the target volume could be clearly marked as OARs and spared during treatment

  8. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  9. Diagnostic utility of DTI in prostate cancer

    International Nuclear Information System (INIS)

    Guerses, Bengi; Tasdelen, Neslihan; Yencilek, Faruk; Kilickesmez, N. Ozguer; Alp, Turgut; Firat, Zeynep; Albayrak, M. Selami; Ulug, Aziz M.; Guermen, A. Nevzat

    2011-01-01

    Purpose: The aim of this study was to compare the diffusion tensor parameters of prostate cancer, prostatitis and normal prostate tissue. Materials and Methods: A total of 25 patients with the suspicion of prostate cancer were included in the study. MRI was performed with 3 T system (Intera Achieva, Philips Medical Systems, The Netherlands). T2 TSE and DTI with ss-EPI were obtained in each subject. TRUS-guided prostate biopsy was performed after the MRI examination. Images were analyzed by two radiologists using a special software system. ROI's were drawn according to biopsy zones which are apex, midgland, base and central zone on each sides of the gland. FA and ADC values in areas of cancer, chronic prostatitis and normal prostate tissue were compared using Student's t-test. Results: Histopathological analysis revealed carcinoma in 68, chronic prostatitis in 67 and was reported as normal in 65 zones. The mean FA of cancerous tissue was significantly higher (p < 0.01) than the FA of chronic prostatitis and normal gland. The mean ADC of cancerous tissue was found to be significantly lower (p < 0.01), compared with non-cancerous tissue. Conclusion: Decreased ADC and increased FA are compatible with the hypercellular nature of prostate tumors. These differences may increase the accuracy of MRI in the detection of carcinoma and to differentiate between cancer and prostatitis.

  10. Diagnostic utility of DTI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guerses, Bengi, E-mail: bengur0@yahoo.com [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Tasdelen, Neslihan [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Yencilek, Faruk [Yeditepe University Medical Faculty, Department of Urology, Istanbul (Turkey); Kilickesmez, N. Ozguer [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Alp, Turgut [Fatih Sultan Mehmet Training and Research Hospital, Division of Urology, Istanbul (Turkey); Firat, Zeynep [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Albayrak, M. Selami [Kartal Training and Research Hospital, Division of Urology, Istanbul (Turkey); Ulug, Aziz M. [Yeditepe University Department of Biomedical Engineering, Istanbul (Turkey); The Feinstein Institute for Medical Research, Manhasset, New York (United States); Guermen, A. Nevzat [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey)

    2011-08-15

    Purpose: The aim of this study was to compare the diffusion tensor parameters of prostate cancer, prostatitis and normal prostate tissue. Materials and Methods: A total of 25 patients with the suspicion of prostate cancer were included in the study. MRI was performed with 3 T system (Intera Achieva, Philips Medical Systems, The Netherlands). T2 TSE and DTI with ss-EPI were obtained in each subject. TRUS-guided prostate biopsy was performed after the MRI examination. Images were analyzed by two radiologists using a special software system. ROI's were drawn according to biopsy zones which are apex, midgland, base and central zone on each sides of the gland. FA and ADC values in areas of cancer, chronic prostatitis and normal prostate tissue were compared using Student's t-test. Results: Histopathological analysis revealed carcinoma in 68, chronic prostatitis in 67 and was reported as normal in 65 zones. The mean FA of cancerous tissue was significantly higher (p < 0.01) than the FA of chronic prostatitis and normal gland. The mean ADC of cancerous tissue was found to be significantly lower (p < 0.01), compared with non-cancerous tissue. Conclusion: Decreased ADC and increased FA are compatible with the hypercellular nature of prostate tumors. These differences may increase the accuracy of MRI in the detection of carcinoma and to differentiate between cancer and prostatitis.

  11. Fractional anisotropy in white matter tracts of very-low-birth-weight infants

    Energy Technology Data Exchange (ETDEWEB)

    Dudink, Jeroen; Conneman, Nikk; Goudoever, Johannes van; Govaert, Paul [Erasmus MC-Sophia Children' s Hospital, Division of Neonatology, Department of Paediatrics, P.O. Box 2060, Rotterdam (Netherlands); Lequin, Maarten [Erasmus MC-Sophia Children' s Hospital, Division of Paediatrics, Department of Radiology, Rotterdam (Netherlands); Pul, Carola van [Maxima Medical Center, Department of Clinical Physics, Veldhoven (Netherlands); Buijs, Jan [Maxima Medical Center, Division of Neonatology, Department of Paediatrics, Veldhoven (Netherlands)

    2007-12-15

    Advances in neonatal intensive care have not yet reduced the high incidence of neurodevelopmental disability among very-low-birth-weight (VLBW) infants. As neurological deficits are related to white-matter injury, early detection is important. Diffusion tensor imaging (DTI) could be an excellent tool for assessment of white-matter injury. To provide DTI fractional anisotropy (FA) reference values for white-matter tracts of VLBW infants for clinical use. We retrospectively analysed DTI images of 28 VLBW infants (26-32 weeks gestational age) without evidence of white-matter abnormalities on conventional MRI sequences, and normal developmental outcome (assessed at age 1-3 years). For DTI an echoplanar sequence with diffusion gradient (b = 1,000 s/mm{sup 2}) applied in 25 non-collinear directions was used. We measured FA and apparent diffusion coefficient (ADC) of different white-matter tracts in the first 4 days of life. A statistically significant correlation was found between gestational age and FA of the posterior limb of the internal capsule in VLBW infants (r = 0.495, P<0.01). Values of FA and ADC were measured in white-matter tracts of VLBW infants. FA of the pyramidal tracts measured in the first few days after birth is related to gestational age. (orig.)

  12. Fractional anisotropy in white matter tracts of very-low-birth-weight infants

    International Nuclear Information System (INIS)

    Dudink, Jeroen; Conneman, Nikk; Goudoever, Johannes van; Govaert, Paul; Lequin, Maarten; Pul, Carola van; Buijs, Jan

    2007-01-01

    Advances in neonatal intensive care have not yet reduced the high incidence of neurodevelopmental disability among very-low-birth-weight (VLBW) infants. As neurological deficits are related to white-matter injury, early detection is important. Diffusion tensor imaging (DTI) could be an excellent tool for assessment of white-matter injury. To provide DTI fractional anisotropy (FA) reference values for white-matter tracts of VLBW infants for clinical use. We retrospectively analysed DTI images of 28 VLBW infants (26-32 weeks gestational age) without evidence of white-matter abnormalities on conventional MRI sequences, and normal developmental outcome (assessed at age 1-3 years). For DTI an echoplanar sequence with diffusion gradient (b = 1,000 s/mm 2 ) applied in 25 non-collinear directions was used. We measured FA and apparent diffusion coefficient (ADC) of different white-matter tracts in the first 4 days of life. A statistically significant correlation was found between gestational age and FA of the posterior limb of the internal capsule in VLBW infants (r = 0.495, P<0.01). Values of FA and ADC were measured in white-matter tracts of VLBW infants. FA of the pyramidal tracts measured in the first few days after birth is related to gestational age. (orig.)

  13. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    International Nuclear Information System (INIS)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor; Kranz, Gottfried; Sycha, Thomas; Hold, Alina

    2015-01-01

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  14. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Kranz, Gottfried; Sycha, Thomas [Medical University of Vienna, Department of Neurology, Vienna (Austria); Hold, Alina [Medical University of Vienna, Department of Plastic and Reconstructive Surgery, Vienna (Austria)

    2015-07-15

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  15. Do different medical curricula influence self-assessed clinical thinking of students?

    Science.gov (United States)

    Gehlhar, Kirsten; Klimke-Jung, Kathrin; Stosch, Christoph; Fischer, Martin R

    2014-01-01

    As a fundamental element of medical practice, clinical reasoning should be cultivated in courses of study in human medicine. To date, however, no conclusive evidence has been offered as to what forms of teaching and learning are most effective in achieving this goal. The Diagnostic Thinking Inventory (DTI) was developed as a means of measuring knowledge-unrelated components of clinical reasoning. The present pilot study examines the adequacy of this instrument in measuring differences in the clinical reasoning of students in varying stages of education in three curricula of medical studies. The Diagnostic Thinking Inventory (DTI) comprises 41 items in two subscales ("Flexibility in Thinking" and "Structure of Knowledge in Memory"). Each item contains a statement or finding concerning clinical reasoning in the form of a stem under which a 6-point scale presents opposing conclusions. The subjects are asked to assess their clinical thinking within this range. The German-language version of the DTI was completed by 247 student volunteers from three schools and varying clinical semesters. In a quasi-experimental design, 219 subjects from traditional and model courses of study in the German state of North Rhine-Westphalia took part. Specifically, these were 5(th), 6(th) and 8(th) semester students from the model course of study at Witten/Herdecke University (W/HU), from the model (7(th) and 9(th) semester) and traditional (7(th) semester) courses of study at the Ruhr University Bochum (RUB) and from the model course of study (9(th) semester) at the University of Cologne (UoC). The data retrieved were quantitatively assessed. The reliability of the questionnaire in its entirety was good (Cronbach's alpha between 0.71 and 0.83); the reliability of the subscales ranged between 0.49 and 0.75. The different groups were compared using the Mann-Whitney test, revealing significant differences among semester cohorts within a school as well as between students from similar

  16. DTI and VBM reveal white matter changes without associated gray matter changes in patients with idiopathic restless legs syndrome

    Science.gov (United States)

    Belke, Marcus; Heverhagen, Johannes T; Keil, Boris; Rosenow, Felix; Oertel, Wolfgang H; Stiasny-Kolster, Karin; Knake, Susanne; Menzler, Katja

    2015-01-01

    Background and Purpose We evaluated cerebral white and gray matter changes in patients with iRLS in order to shed light on the pathophysiology of this disease. Methods Twelve patients with iRLS were compared to 12 age- and sex-matched controls using whole-head diffusion tensor imaging (DTI) and voxel-based morphometry (VBM) techniques. Evaluation of the DTI scans included the voxelwise analysis of the fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD). Results Diffusion tensor imaging revealed areas of altered FA in subcortical white matter bilaterally, mainly in temporal regions as well as in the right internal capsule, the pons, and the right cerebellum. These changes overlapped with changes in RD. Voxel-based morphometry did not reveal any gray matter alterations. Conclusions We showed altered diffusion properties in several white matter regions in patients with iRLS. White matter changes could mainly be attributed to changes in RD, a parameter thought to reflect altered myelination. Areas with altered white matter microstructure included areas in the internal capsule which include the corticospinal tract to the lower limbs, thereby supporting studies that suggest changes in sensorimotor pathways associated with RLS. PMID:26442748

  17. Low-gradient aortic stenosis.

    Science.gov (United States)

    Clavel, Marie-Annick; Magne, Julien; Pibarot, Philippe

    2016-09-07

    An important proportion of patients with aortic stenosis (AS) have a 'low-gradient' AS, i.e. a small aortic valve area (AVA gradient (gradient discrepancy raises uncertainty about the actual stenosis severity and thus about the indication for aortic valve replacement (AVR) if the patient has symptoms and/or left ventricular (LV) systolic dysfunction. The most frequent cause of low-gradient (LG) AS is the presence of a low LV outflow state, which may occur with reduced left ventricular ejection fraction (LVEF), i.e. classical low-flow, low-gradient (LF-LG), or preserved LVEF, i.e. paradoxical LF-LG. Furthermore, a substantial proportion of patients with AS may have a normal-flow, low-gradient (NF-LG) AS: i.e. a small AVA-low-gradient combination but with a normal flow. One of the most important clinical challenges in these three categories of patients with LG AS (classical LF-LG, paradoxical LF-LG, and NF-LG) is to differentiate a true-severe AS that generally benefits from AVR vs. a pseudo-severe AS that should be managed conservatively. A low-dose dobutamine stress echocardiography may be used for this purpose in patients with classical LF-LG AS, whereas aortic valve calcium scoring by multi-detector computed tomography is the preferred modality in those with paradoxical LF-LG or NF-LG AS. Although patients with LF-LG severe AS have worse outcomes than those with high-gradient AS following AVR, they nonetheless display an important survival benefit with this intervention. Some studies suggest that transcatheter AVR may be superior to surgical AVR in patients with LF-LG AS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  18. UK DTI wind programme area - review and current priorities

    International Nuclear Information System (INIS)

    Craig, J.W.

    1998-01-01

    The Wind Energy programme commenced in 1979 initially to determine the technical and economic feasibility of the technology. Since that time the programme has progressed from research, development and assessment to commercial deployment. It now provides a technology push to complement the market pull created by the Non-Fossil Fuel Obligation (NFFO). Over 280 MW of capacity has now been commissioned. The wind energy programme, is based upon a five year strategy in common with other DTI renewable energy technologies, which were outlined in Energy Paper 62. The programme has four key aims: 1. To encourage the uptake of wind energy. 2. To encourage internationally competitive industries to develop and utilise capabilities for the domestic and export markets. 3. To quantify environmental improvements and disbenefits associated with wind energy. 4. To manage the programme effectively. During the mid 1980s and early 1990s the programme concentrated on technology development and demonstration, which has helped to establish UK expertise in wind energy. Non-technical barriers such as planning have been addressed but are now largely for the industry to resolve. The development of wind turbine technology and related components is aimed at meeting the challenge of both the domestic and world markets. The ability of the DTI programme to meet these challenges is partly dependent on the technical ability and commercially acumen of British companies and partly on the level of support offered by Government. The programme budget has fallen from Pound8.7M/year in 1992/93 to current level of Pound1.4M/year and is yet to fall further. It should be stressed that the decline in budgets followed a review of the Renewables Programme in 1995 which affected all technologies. The wind programme budget was reduced substantially at that time which resulted in a revision of priorities. Continued support for market enablement measures was reduced partly because the industry, supported by the NFFO

  19. Neonatal brain microstructure correlates of neurodevelopment and gait in preterm children 18-22 mo of age: an MRI and DTI study.

    Science.gov (United States)

    Rose, Jessica; Cahill-Rowley, Katelyn; Vassar, Rachel; Yeom, Kristen W; Stecher, Ximena; Stevenson, David K; Hintz, Susan R; Barnea-Goraly, Naama

    2015-12-01

    Near-term brain structure was examined in preterm infants in relation to neurodevelopment. We hypothesized that near-term macrostructural brain abnormalities identified using conventional magnetic resonance imaging (MRI), and white matter (WM) microstructure detected using diffusion tensor imaging (DTI), would correlate with lower cognitive and motor development and slower, less-stable gait at 18-22 mo of age. One hundred and two very-low-birth-weight preterm infants (≤1,500 g birth weight; ≤32 wk gestational age) were recruited prior to routine near-term brain MRI at 36.6 ± 1.8 wk postmenstrual age. Cerebellar and WM macrostructure was assessed on conventional structural MRI. DTI was obtained in 66 out of 102 and WM microstructure was assessed using fractional anisotropy and mean diffusivity (MD) in six subcortical brain regions defined by DiffeoMap neonatal atlas. Neurodevelopment was assessed with Bayley-Scales-of-Infant-Toddler-Development, 3rd-Edition (BSID-III); gait was assessed using an instrumented mat. Neonates with cerebellar abnormalities identified using MRI demonstrated lower mean BSID-III cognitive composite scores (89.0 ± 10.1 vs. 97.8 ± 12.4; P = 0.002) at 18-22 mo. Neonates with higher DTI-derived left posterior limb of internal capsule (PLIC) MD demonstrated lower cognitive and motor composite scores (r = -0.368; P = 0.004; r = -0.354; P = 0.006) at 18-22 mo; neonates with higher genu MD demonstrated slower gait velocity (r = -0.374; P = 0.007). Multivariate linear regression significantly predicted cognitive (adjusted r(2) = 0.247; P = 0.002) and motor score (adjusted r(2) = 0.131; P = 0.017). Near-term cerebellar macrostructure and PLIC and genu microstructure were predictive of early neurodevelopment and gait.

  20. Clinical and Paraclinical Indicators of Motor System Impairment in Hereditary Spastic Paraplegia: A Pilot Study.

    Directory of Open Access Journals (Sweden)

    Andrea Martinuzzi

    Full Text Available Hereditary spastic paraplegias (HSP are a composite and genetically heterogeneous group of conditions mainly expressed by the impairment of the central motor system ("pure" forms. The involvement of other components of the central nervous system or of other systems is described in the "complicate" forms. The definition of an investigation protocol capable, by assembling clinical and paraclinical indicators to fully represent the extent of the motor system impairment, would help both the clinical handling of these conditions and contribute to our understanding of their pathogenesis.We applied a clinical and paraclinical protocol which included tools exploring motor and non motor functioning, neurophysiology and MRI to a composite cohort of 70 molecularly defined HSP patients aged 3 to 65, to define for each indicator its significance in detailing the presence and the severity of the pathology.Clinically increased deep tendon reflexes and lower limb (LL weakness are constant findings in all patients. The "complicated" forms are characterized by peripheral motor impairment, cognitive and cerebellar involvement. The Spastic Paraplegia Rating Scale efficiently reflects the severity of functional problems and correlates with disease duration. Neurophysiology consistently documents the impairment of the central motor pathway to the LLs. Nevertheless, the upper extremities and sensory system involvement is a frequent finding. MRI diffusion tensor imaging (DTI highlighted a significant alteration of FA and MD. Combining the sampling of the various portion of the cortico-spinal tract (CST DTI consistently discriminated patients from controls.We propose a graded clinical and paraclinical protocol for HSP phenotype definition, indicating for each tool the discriminative and descriptive capacity. Our protocol applied to 9 different forms of HSP showed that the functional impairment often extends beyond the CST. The novel DTI approach may add significant

  1. Clinical and Paraclinical Indicators of Motor System Impairment in Hereditary Spastic Paraplegia: A Pilot Study.

    Science.gov (United States)

    Martinuzzi, Andrea; Montanaro, Domenico; Vavla, Marinela; Paparella, Gabriella; Bonanni, Paolo; Musumeci, Olimpia; Brighina, Erika; Hlavata, Hana; Rossi, Giuseppe; Aghakhanyan, Gayane; Martino, Nicola; Baratto, Alessandra; D'Angelo, Maria Grazia; Peruch, Francesca; Fantin, Marianna; Arnoldi, Alessia; Citterio, Andrea; Vantaggiato, Chiara; Rizzo, Vincenzo; Toscano, Antonio; Bresolin, Nereo; Bassi, Maria Teresa

    2016-01-01

    Hereditary spastic paraplegias (HSP) are a composite and genetically heterogeneous group of conditions mainly expressed by the impairment of the central motor system ("pure" forms). The involvement of other components of the central nervous system or of other systems is described in the "complicate" forms. The definition of an investigation protocol capable, by assembling clinical and paraclinical indicators to fully represent the extent of the motor system impairment, would help both the clinical handling of these conditions and contribute to our understanding of their pathogenesis. We applied a clinical and paraclinical protocol which included tools exploring motor and non motor functioning, neurophysiology and MRI to a composite cohort of 70 molecularly defined HSP patients aged 3 to 65, to define for each indicator its significance in detailing the presence and the severity of the pathology. Clinically increased deep tendon reflexes and lower limb (LL) weakness are constant findings in all patients. The "complicated" forms are characterized by peripheral motor impairment, cognitive and cerebellar involvement. The Spastic Paraplegia Rating Scale efficiently reflects the severity of functional problems and correlates with disease duration. Neurophysiology consistently documents the impairment of the central motor pathway to the LLs. Nevertheless, the upper extremities and sensory system involvement is a frequent finding. MRI diffusion tensor imaging (DTI) highlighted a significant alteration of FA and MD. Combining the sampling of the various portion of the cortico-spinal tract (CST) DTI consistently discriminated patients from controls. We propose a graded clinical and paraclinical protocol for HSP phenotype definition, indicating for each tool the discriminative and descriptive capacity. Our protocol applied to 9 different forms of HSP showed that the functional impairment often extends beyond the CST. The novel DTI approach may add significant elements in

  2. Diffusion tensor MRI: clinical applications

    International Nuclear Information System (INIS)

    Meli, Francisco; Romero, Carlos; Carpintiero, Silvina; Salvatico, Rosana; Lambre, Hector; Vila, Jose

    2005-01-01

    Purpose: To evaluate the usefulness of diffusion-tensor imaging (DTI) on different neurological diseases, and to know if this technique shows additional information than conventional Magnetic Resonance Imaging (MRI). Materials and method: Eight patients, with neurological diseases (five patients with brain tumors, one with multiple sclerosis (MS), one with variant Creutzfeldt-Jakob disease (vCJD) and the other with delayed CO intoxication were evaluated. A MR scanner of 1.5 T was used and conventional sequences and DTI with twenty-five directions were done. Quantitative maps were gotten, where the fractional anisotropy (FA) through regions of interest (ROIs) in specific anatomic area were quantified (i.e.: internal and external capsules, frontal and temporal bundles, corpus fibers). Results: In the patients with brain tumors, there was a decrease of FA on intra and peritumoral fibers. Some of them had a disruption in their pattern. In patients with MS and CO intoxication, partial interruption along white matter bundles was demonstrated. However, a 'mismatch' between the findings of FLAIR, Diffusion-weighted images (DWI) and DTI, in the case of CO intoxication, was seen. Conclusions: DTI gave more information compared to conventional sequences about ultrastructural brain tissue in almost all the diseases above mentioned. Therefore, there is a work in progress about DTI acquisition, to evaluate a new technique, called tractography. (author)

  3. Distortion-free diffusion tensor imaging for evaluation of lumbar nerve roots: Utility of direct coronal single-shot turbo spin-echo diffusion sequence.

    Science.gov (United States)

    Sakai, Takayuki; Doi, Kunio; Yoneyama, Masami; Watanabe, Atsuya; Miyati, Tosiaki; Yanagawa, Noriyuki

    2018-06-01

    Diffusion tensor imaging (DTI) based on a single-shot echo planer imaging (EPI-DTI) is an established method that has been used for evaluation of lumbar nerve disorders in previous studies, but EPI-DTI has problems such as a long acquisition time, due to a lot of axial slices, and geometric distortion. To solve these problems, we attempted to apply DTI based on a single-shot turbo spin echo (TSE-DTI) with direct coronal acquisition. Our purpose in this study was to investigate whether TSE-DTI may be more useful for evaluation of lumbar nerve disorders than EPI-DTI. First, lumbar nerve roots of five healthy volunteers were evaluated for optimization of imaging parameters with TSE-DTI including b-values and the number of motion proving gradient (MPG) directions. Subsequently, optimized TSE-DTI was quantitatively compared with conventional EPI-DTI by using fractional anisotropy (FA) values and visual scores in subjective visual evaluation of tractography. Lumbar nerve roots of six patients, who had unilateral neurologic symptoms in one leg, were evaluated by the optimized TSE-DTI. TSE-DTI with b-value of 400 s/mm 2 and 32 diffusion-directions could reduce the image distortion compared with EPI-DTI, and showed that the average FA values on the symptomatic side for six patients were significantly lower than those on the non-symptomatic side (P DTI might show damaged areas of lumbar nerve roots without severe image distortion. TSE-DTI might improve the reproducibility in measurements of FA values for quantification of a nerve disorder, and would become a useful tool for diagnosis of low back pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Analysis of fractional anisotropy facilitates differentiation of glioblastoma and brain metastases in a clinical setting

    Energy Technology Data Exchange (ETDEWEB)

    Bette, Stefanie, E-mail: stefanie.bette@tum.de [Department of Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Huber, Thomas; Wiestler, Benedikt; Boeckh-Behrens, Tobias [Department of Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Gempt, Jens; Ringel, Florian; Meyer, Bernhard [Department of Neurosurgery, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Zimmer, Claus; Kirschke, Jan S. [Department of Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany)

    2016-12-15

    Purpose: Differentiating glioblastoma from brain metastases is important for therapy planning. Diffusion tensor imaging (DTI) was described as a promising tool, however with conflicting results. Aim: of this study was to analyze the clinical utility of DTI for the differentiation of brain metastases and glioblastoma. Methods: 294 patients (165 glioblastoma, 129 brain metastases) with preoperative DTI were included in this retrospective study. Fractional anisotropy (FA) was measured via regions of interest (ROIs) in the contrast-enhancing tumor, the necrosis and the FLAIR-hyperintense non-enhancing peritumoral region (NEPTR). Two neuroradiologists classified patient cases as glioblastoma or brain metastases without and with knowledge of FA values. Results: Glioblastoma showed significantly higher FA{sub contrast} (median glioblastoma = 0.33, metastases = 0.23; P < 0.001) whereas no significant difference was observed for FA{sub NEPTR} (0.21 vs. 0.22; P = 0.28) and for FA{sub necrosis} (0.17 vs. 0.18, P = 0.37). FA improved diagnostic accuracy of the neuroradiologists significantly from an AUC of 0.84/0.85 (Reader1/Reader2) to 0.89/0.92. Conclusions: Glioblastoma show significantly higher FA values in the contrast enhancing tumor part than brain metastases. Implementation of a ROI-based measurement of FA values and FA color maps in clinical routine helps to differentiate between glioblastoma and brain metastases.

  5. Clinical correlates of decreased anteroposterior metabolic gradients in positron emission tomography (PET) of schizophrenic patients

    International Nuclear Information System (INIS)

    DeLisi, L.E.; Buchsbaum, M.S.; Holcomb, H.H.

    1985-01-01

    The finding in schizophrenic patients of a reversal of the normal frontal to posterior pattern of brain metabolic activity with positron emission tomography (PET) is of interest, but its relevance to psychopathology is unknown. Using PET, the authors studied 21 patients with chronic schizophrenia and 21 age- and sex-matched control subjects. Although eight of the 21 patients and only one of the control subjects showed a relatively lower anteroposterior metabolic gradient, no clinical correlates of this finding were noted. In addition, cerebral atrophy, as determined by CAT scan, was not associated with this aberrant metabolic pattern

  6. Multilevel Deficiency of White Matter Connectivity Networks in Alzheimer's Disease: A Diffusion MRI Study with DTI and HARDI Models.

    Science.gov (United States)

    Wang, Tao; Shi, Feng; Jin, Yan; Yap, Pew-Thian; Wee, Chong-Yaw; Zhang, Jianye; Yang, Cece; Li, Xia; Xiao, Shifu; Shen, Dinggang

    2016-01-01

    Alzheimer's disease (AD) is the most common form of dementia in elderly people. It is an irreversible and progressive brain disease. In this paper, we utilized diffusion-weighted imaging (DWI) to detect abnormal topological organization of white matter (WM) structural networks. We compared the differences between WM connectivity characteristics at global, regional, and local levels in 26 patients with probable AD and 16 normal control (NC) elderly subjects, using connectivity networks constructed with the diffusion tensor imaging (DTI) model and the high angular resolution diffusion imaging (HARDI) model, respectively. At the global level, we found that the WM structural networks of both AD and NC groups had a small-world topology; however, the AD group showed a significant decrease in both global and local efficiency, but an increase in clustering coefficient and the average shortest path length. We further found that the AD patients had significantly decreased nodal efficiency at the regional level, as well as weaker connections in multiple local cortical and subcortical regions, such as precuneus, temporal lobe, hippocampus, and thalamus. The HARDI model was found to be more advantageous than the DTI model, as it was more sensitive to the deficiencies in AD at all of the three levels.

  7. The DTI FSU Nuclear legacy programme: UK experience of radiation protection at Andreeva Bay

    International Nuclear Information System (INIS)

    Hammon, C.; Parker, R.

    2006-01-01

    Full text of publication follows: The United Kingdom (UK) has committed substantial long term funding to the Former Soviet Union (FSU) to assist with their nuclear legacy as part of the UK contribution to the G8 Global Partnership. The budget is managed by the UK Department of Trade and Industry (DTI) and RWE NUKEM are the programme management consultants for the Nuclear Legacy programme, which includes the Andreeva Bay project. The fundamental driver for the DTI is to improve the safety, security and non-proliferation of fissile material and RWE NUKEM is working closely with the DTI to achieve this. Andreeva Bay is located in the extreme north -west of the Kola Peninsula in Russia. The site was established in the 1960's to be used for the interim storage of used nuclear fuel, and solid and liquid radioactive wastes arising from the operation of nuclear powered submarines and icebreakers. However, leakage in the spent fuel pond storage facility during the late 1970's resulted in the emergency transfer of the fuel (20,000 spent fuel assemblies) to 3 dry storage tanks, which are now in very poor condition, and a highly contaminated pond storage facility, Building 5. The objectives of the project are to identify and implement solutions for the existing safety, security and environmental problems of SNF. One of the tasks at Andreeva Bay was to work together with the Russian site operators with the aim of improving standards of radiation protection on the site. This is being achieved by providing the Russians with funding to enable them to implement measures to improve radiological safety. The following measures have been put in place so far: the introduction of a Radiation Management System, the provision of mobile and permanent staff change room facilities, the provision of decontamination facilities, the provision of radiation protection instrumentation, the provision of laboratory facilities, the provision of secondary waste storage containers, the provision of

  8. Social gradients in periodontal diseases among adolescents.

    Science.gov (United States)

    López, Rodrigo; Fernández, Olaya; Baelum, Vibeke

    2006-06-01

    To investigate the association between socioeconomic position and periodontal diseases among adolescents. Data were obtained from 9203 Chilean high school students. Clinical examinations included direct recordings of clinical attachment level and the necrotizing ulcerative gingival lesions. Students answered a questionnaire on various dimensions of socioeconomic position. Seven periodontal outcomes were analyzed. Logistic regression analyses were used to identify socioeconomic variables associated with the periodontal outcomes. The occurrence of all periodontal outcomes investigated followed social gradients, and paternal income and parental education were the most influential variables. The study demonstrates the existence of significant social gradients in periodontal diseases already among adolescents. This is worrying, and indicates a new potential for further insight into the mechanisms of periodontal disease causation.

  9. Predicting the laterality of temporal lobe epilepsy from PET, MRI, and DTI: A multimodal study

    Directory of Open Access Journals (Sweden)

    Dorian Pustina

    2015-01-01

    Full Text Available Pre-surgical evaluation of patients with temporal lobe epilepsy (TLE relies on information obtained from multiple neuroimaging modalities. The relationship between modalities and their combined power in predicting the seizure focus is currently unknown. We investigated asymmetries from three different modalities, PET (glucose metabolism, MRI (cortical thickness, and diffusion tensor imaging (DTI; white matter anisotropy in 28 left and 30 right TLE patients (LTLE and RTLE. Stepwise logistic regression models were built from each modality separately and from all three combined, while bootstrapped methods and split-sample validation verified the robustness of predictions. Among all multimodal asymmetries, three PET asymmetries formed the best predictive model (100% success in full sample, >95% success in split-sample validation. The combinations of PET with other modalities did not perform better than PET alone. Probabilistic classifications were obtained for new clinical cases, which showed correct lateralization for 7/7 new TLE patients (100% and for 4/5 operated patients with discordant or non-informative PET reports (80%. Metabolism showed closer relationship with white matter in LTLE and closer relationship with gray matter in RTLE. Our data suggest that metabolism is a powerful modality that can predict seizure laterality with high accuracy, and offers high value for automated predictive models. The side of epileptogenic focus can affect the relationship of metabolism with brain structure. The data and tools necessary to obtain classifications for new TLE patients are made publicly available.

  10. Post-mortem inference of the human hippocampal connectivity and microstructure using ultra-high field diffusion MRI at 11.7 T.

    Science.gov (United States)

    Beaujoin, Justine; Palomero-Gallagher, Nicola; Boumezbeur, Fawzi; Axer, Markus; Bernard, Jeremy; Poupon, Fabrice; Schmitz, Daniel; Mangin, Jean-François; Poupon, Cyril

    2018-06-01

    The human hippocampus plays a key role in memory management and is one of the first structures affected by Alzheimer's disease. Ultra-high magnetic resonance imaging provides access to its inner structure in vivo. However, gradient limitations on clinical systems hinder access to its inner connectivity and microstructure. A major target of this paper is the demonstration of diffusion MRI potential, using ultra-high field (11.7 T) and strong gradients (750 mT/m), to reveal the extra- and intra-hippocampal connectivity in addition to its microstructure. To this purpose, a multiple-shell diffusion-weighted acquisition protocol was developed to reach an ultra-high spatio-angular resolution with a good signal-to-noise ratio. The MRI data set was analyzed using analytical Q-Ball Imaging, Diffusion Tensor Imaging (DTI), and Neurite Orientation Dispersion and Density Imaging models. High Angular Resolution Diffusion Imaging estimates allowed us to obtain an accurate tractography resolving more complex fiber architecture than DTI models, and subsequently provided a map of the cross-regional connectivity. The neurite density was akin to that found in the histological literature, revealing the three hippocampal layers. Moreover, a gradient of connectivity and neurite density was observed between the anterior and the posterior part of the hippocampus. These results demonstrate that ex vivo ultra-high field/ultra-high gradients diffusion-weighted MRI allows the mapping of the inner connectivity of the human hippocampus, its microstructure, and to accurately reconstruct elements of the polysynaptic intra-hippocampal pathway using fiber tractography techniques at very high spatial/angular resolutions.

  11. Multilevel Deficiency of White Matter Connectivity Networks in Alzheimer’s Disease: A Diffusion MRI Study with DTI and HARDI Models

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2016-01-01

    Full Text Available Alzheimer’s disease (AD is the most common form of dementia in elderly people. It is an irreversible and progressive brain disease. In this paper, we utilized diffusion-weighted imaging (DWI to detect abnormal topological organization of white matter (WM structural networks. We compared the differences between WM connectivity characteristics at global, regional, and local levels in 26 patients with probable AD and 16 normal control (NC elderly subjects, using connectivity networks constructed with the diffusion tensor imaging (DTI model and the high angular resolution diffusion imaging (HARDI model, respectively. At the global level, we found that the WM structural networks of both AD and NC groups had a small-world topology; however, the AD group showed a significant decrease in both global and local efficiency, but an increase in clustering coefficient and the average shortest path length. We further found that the AD patients had significantly decreased nodal efficiency at the regional level, as well as weaker connections in multiple local cortical and subcortical regions, such as precuneus, temporal lobe, hippocampus, and thalamus. The HARDI model was found to be more advantageous than the DTI model, as it was more sensitive to the deficiencies in AD at all of the three levels.

  12. Structural and diffusion imaging versus clinical assessment to monitor amyotrophic lateral sclerosis

    Directory of Open Access Journals (Sweden)

    Arturo Cardenas-Blanco

    2016-01-01

    Full Text Available Amyotrophic lateral sclerosis is a progressive neurodegenerative disease that affects upper and lower motor neurons. Observational and intervention studies can be tracked using clinical measures such as the revised Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS-R but for a complete understanding of disease progression, objective in vivo biomarkers of both central and peripheral motor pathway pathology are highly desirable. The aim of this study was to determine the utility of structural and diffusion imaging as central nervous system biomarkers compared to the standard clinical measure, ALSFRS-R, to track longitudinal evolution using three time-point measurements. N = 34 patients with ALS were scanned and clinically assessed three times at a mean of three month time intervals. The MRI biomarkers were structural T1-weighted volumes for cortical thickness measurement as well as deep grey matter volumetry, voxel-based morphometry and diffusion tensor imaging (DTI. Cortical thickness focused specifically on the precentral gyrus while quantitative DTI biomarkers focused on the corticospinal tracts. The evolution of imaging biomarkers and ALSFRS-R scores over time were analysed using a mixed effects model that accounted for the scanning interval as a fixed effect variable, and, the initial measurements and time from onset as random variables. The mixed effects model showed a significant decrease in the ALSFRS-R score, (p  0.5. In addition, deep grey matter volumetry and voxel-based morphometry also identified no significant changes. Furthermore, the availability of three time points was able to indicate that there was a linear progression in both clinical and fractional anisotropy measures adding to the validity of these results. The results indicate that DTI is clearly a superior imaging marker compared to atrophy for tracking the evolution of the disease and can act as a central nervous biomarker in longitudinal studies. It

  13. Interhemispheric Functional and Structural Disconnection in Alzheimer's Disease: A Combined Resting-State fMRI and DTI Study.

    Directory of Open Access Journals (Sweden)

    Zhiqun Wang

    Full Text Available Neuroimaging studies have demonstrated that patients with Alzheimer's disease presented disconnection syndrome. However, little is known about the alterations of interhemispheric functional interactions and underlying structural connectivity in the AD patients. In this study, we combined resting-state functional MRI and diffusion tensor imaging (DTI to investigate interhemispheric functional and structural connectivity in 16 AD, 16 mild cognitive impairment (MCI, as well as 16 cognitive normal healthy subjects (CN. The pattern of the resting state interhemispheric functional connectivity was measured with a voxel-mirrored homotopic connectivity (VMHC method. Decreased VMHC was observed in AD and MCI subjects in anterior brain regions including the prefrontal cortices and subcortical regions with a pattern of ADDTI analysis showed the most significant difference among the three cohorts was the fractional anisotropy in the genu of corpus callosum, which was positively associated with the VMHC of prefrontal and subcortical regions. Across all the three cohorts, the diffusion parameters in the genu of corpus callosum and VMHC in the above brain regions had significant correlation with the cognitive performance. These results demonstrate that there are specific patterns of interhemispheric functional connectivity changes in the AD and MCI, which can be significantly correlated with the integrity changes in the midline white matter structures. These results suggest that VMHC can be used as a biomarker for the degeneration of the interhemispheric connectivity in AD.

  14. Alterations of brain network hubs in reflex syncope: Evidence from a graph theoretical analysis based on DTI.

    Science.gov (United States)

    Park, Bong Soo; Lee, Yoo Jin; Park, Jin-Han; Kim, Il Hwan; Park, Si Hyung; Lee, Ho-Joon; Park, Kang Min

    2018-06-01

    We evaluated global topology and organization of regional hubs in the brain networks and microstructural abnormalities in the white matter of patients with reflex syncope. Twenty patients with reflex syncope and thirty healthy subjects were recruited, and they underwent diffusion tensor imaging (DTI) scans. Graph theory was applied to obtain network measures based on extracted DTI data, using DSI Studio. We then investigated differences in the network measures between the patients with reflex syncope and the healthy subjects. We also analyzed microstructural abnormalities of white matter using tract-based spatial statistics analysis (TBSS). Measures of global topology were not different between patients with reflex syncope and healthy subjects. However, in reflex syncope patients, the strength measures of the right angular, left inferior frontal, left middle orbitofrontal, left superior medial frontal, and left middle temporal gyrus were lower than in healthy subjects. The betweenness centrality measures of the left middle orbitofrontal, left fusiform, and left lingual gyrus in patients were lower than those in healthy subjects. The PageRank centrality measures of the right angular, left middle orbitofrontal, and left superior medial frontal gyrus in patients were lower than those in healthy subjects. Regarding the analysis of the white matter microstructure, there were no differences in the fractional anisotropy and mean diffusivity values between the two groups. We have identified a reorganization of network hubs in the brain network of patients with reflex syncope. These alterations in brain network may play a role in the pathophysiologic mechanism underlying reflex syncope. © 2018 The Authors. Brain and Behavior published by Wiley Periodicals, Inc.

  15. A T1 and DTI fused 3D corpus callosum analysis in pre- vs. post-season contact sports players

    Science.gov (United States)

    Lao, Yi; Law, Meng; Shi, Jie; Gajawelli, Niharika; Haas, Lauren; Wang, Yalin; Leporé, Natasha

    2015-01-01

    Sports related traumatic brain injury (TBI) is a worldwide public health issue, and damage to the corpus callosum (CC) has been considered as an important indicator of TBI. However, contact sports players suffer repeated hits to the head during the course of a season even in the absence of diagnosed concussion, and less is known about their effect on callosal anatomy. In addition, T1-weighted and diffusion tensor brain magnetic resonance images (DTI) have been analyzed separately, but a joint analysis of both types of data may increase statistical power and give a more complete understanding of anatomical correlates of subclinical concussions in these athletes. Here, for the first time, we fuse T1 surface-based morphometry and a new DTI analysis on 3D surface representations of the CCs into a single statistical analysis on these subjects. Our new combined method successfully increases detection power in detecting differences between pre- vs. post-season contact sports players. Alterations are found in the ventral genu, isthmus, and splenium of CC. Our findings may inform future health assessments in contact sports players. The new method here is also the first truly multimodal diffusion and T1-weighted analysis of the CC, and may be useful to detect anatomical changes in the corpus callosum in other multimodal datasets.

  16. Clinical heterogeneity among people with high functioning autism spectrum conditions: evidence favouring a continuous severity gradient

    Directory of Open Access Journals (Sweden)

    Woodbury-Smith Marc

    2008-02-01

    Full Text Available Abstract Background Autism Spectrum Conditions (ASCs are characterized by a high degree of clinical heterogeneity, but the extent to which this variation represents a severity gradient versus discrete phenotypes is unclear. This issue has complicated genetic studies seeking to investigate the genetic basis of the high hereditability observed clinically in those with an ASC. The aim of this study was to examine the possible clustering of symptoms associated with ASCs to determine whether the observed distribution of symptom type and severity supported either a severity or a symptom subgroup model to account for the phenotypic variation observed within the ASCs. Methods We investigated the responses of a group of adults with higher functioning ASCs on the fifty clinical features examined in the Autism Spectrum Quotient, a screening questionnaire used in the diagnosis of higher functioning ASCs. In contrast to previous studies we have used this instrument with no a priori assumptions about any underlying factor structure of constituent items. The responses obtained were analyzed using complete linkage hierarchical cluster analysis. For the members of each cluster identified the mean score on each Autism Spectrum Quotient question was calculated. Results Autism Spectrum Quotient responses from a total of 333 individuals between the ages of 16.6 and 78.0 years were entered into the hierarchical cluster analysis. The four cluster solution was the one that generated the largest number of clusters that did not also include very small cluster sizes, defined as a membership comprising 10 individuals or fewer. Examination of these clusters demonstrated that they varied in total Autism Spectrum Quotient but that the profiles across the symptoms comprising the Autism Spectrum Quotient did not differ independently of this severity factor. Conclusion These results are consistent with a unitary spectrum model, suggesting that the clinical heterogeneity observed

  17. Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging.

    Science.gov (United States)

    Truong, Trong-Kha; Song, Allen W; Chen, Nan-Kuei

    2015-01-01

    In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

  18. A Unified Approach to Diffusion Direction Sensitive Slice Registration and 3-D DTI Reconstruction From Moving Fetal Brain Anatomy

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Seshamani, Sharmishtaa; Kroenke, Christopher

    2014-01-01

    to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction...... (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired...

  19. Fifty shades of gradients: does the pressure gradient in venous sinus stenting for idiopathic intracranial hypertension matter? A systematic review.

    Science.gov (United States)

    McDougall, Cameron M; Ban, Vin Shen; Beecher, Jeffrey; Pride, Lee; Welch, Babu G

    2018-03-02

    OBJECTIVE The role of venous sinus stenting (VSS) for idiopathic intracranial hypertension (IIH) is not well understood. The aim of this systematic review is to attempt to identify subsets of patients with IIH who will benefit from VSS based on the pressure gradients of their venous sinus stenosis. METHODS MEDLINE/PubMed was searched for studies reporting venous pressure gradients across the stenotic segment of the venous sinus, pre- and post-stent pressure gradients, and clinical outcomes after VSS. Findings are reported according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. RESULTS From 32 eligible studies, a total of 186 patients were included in the analysis. Patients who had favorable outcomes had higher mean pressure gradients (22.8 ± 11.5 mm Hg vs 17.4 ± 8.0 mm Hg, p = 0.033) and higher changes in pressure gradients after stent placement (19.4 ± 10.0 mm Hg vs 12.0 ± 6.0 mm Hg, p = 0.006) compared with those with unfavorable outcomes. The post-stent pressure gradients between the 2 groups were not significantly different (2.8 ± 4.0 mm Hg vs 2.7 ± 2.0 mm Hg, p = 0.934). In a multivariate stepwise logistic regression controlling for age, sex, body mass index, CSF opening pressure, pre-stent pressure gradient, and post-stent pressure gradient, the change in pressure gradient with stent placement was found to be an independent predictor of favorable outcome (p = 0.028). Using a pressure gradient of 21 as a cutoff, 81/86 (94.2%) of patients with a gradient > 21 achieved favorable outcomes, compared with 82/100 (82.0%) of patients with a gradient ≤ 21 (p = 0.022). CONCLUSIONS There appears to be a relationship between the pressure gradient of venous sinus stenosis and the success of VSS in IIH. A randomized controlled trial would help elucidate this relationship and potentially guide patient selection.

  20. Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.

    Science.gov (United States)

    Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L

    2014-03-01

    Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.

  1. The influence of ALN-Al gradient material gradient index on ballistic performance

    International Nuclear Information System (INIS)

    Wang Youcong; Liu Qiwen; Li Yao; Shen Qiang

    2013-01-01

    Ballistic performance of the gradient material is superior to laminated material, and gradient materials have different gradient types. Using ls-dyna to simulate the ballistic performance of ALN-AL gradient target plates which contain three gradient index (b = 1, b = 0.5, b = 2). Through Hopkinson bar numerical simulation to the target plate materials, we obtained the reflection stress wave and transmission stress wave state of gradient material to get the best gradient index. The internal stress state of gradient material is simulated by amplification processing of the target plate model. When the gradient index b is equal to 1, the gradient target plate is best of all.

  2. Clinical impacts of 3.0 Tesla magnetic resonance imaging in stroke patients

    International Nuclear Information System (INIS)

    Inoue, Takashi; Ogasawara, Kuniaki; Ogawa, Akira

    2004-01-01

    The progress of the magnetic resonance (MR) imaging in the cerebral stroke patients was remarkable, and it became possible to evaluate a brain perfusion or function. Here, we describe about the clinical application of the neuronal tracts and brain perfusion evaluation using 3.0 Tesla MR imaging. The subjects were patients with internal cerebral hemorrhage and major cerebral occlusive diseases. Three dimensional anisotropy contrast (3DAC) imaging and diffusion tensor imaging (DTI) were accepted to estimate the damages of neurnal tracts. Perfusion weighted images with the contrast medium were performed for a quantitative evaluation. The pyramidal tracts were depicted well with 3DAC imaging. Fractional anisotropy (FA) value generated from DTI can predict the outcome of the motor dysfunction in each patient at early stage. Cerebral blood volume calculated from perfusion weighted imaging (PWI) was correlated with and cerebral vascular reserve capacity. 3.0 Tesla MR imaging may develop in cerebral stroke patients in near future. (author)

  3. Evaluation of glymphatic system activity with the diffusion MR technique: diffusion tensor image analysis along the perivascular space (DTI-ALPS) in Alzheimer's disease cases.

    Science.gov (United States)

    Taoka, Toshiaki; Masutani, Yoshitaka; Kawai, Hisashi; Nakane, Toshiki; Matsuoka, Kiwamu; Yasuno, Fumihiko; Kishimoto, Toshifumi; Naganawa, Shinji

    2017-04-01

    The activity of the glymphatic system is impaired in animal models of Alzheimer's disease (AD). We evaluated the activity of the human glymphatic system in cases of AD with a diffusion-based technique called diffusion tensor image analysis along the perivascular space (DTI-ALPS). Diffusion tensor images were acquired to calculate diffusivities in the x, y, and z axes of the plane of the lateral ventricle body in 31 patients. We evaluated the diffusivity along the perivascular spaces as well as projection fibers and association fibers separately, to acquire an index for diffusivity along the perivascular space (ALPS-index) and correlated them with the mini mental state examinations (MMSE) score. We found a significant negative correlation between diffusivity along the projection fibers and association fibers. We also observed a significant positive correlation between diffusivity along perivascular spaces shown as ALPS-index and the MMSE score, indicating lower water diffusivity along the perivascular space in relation to AD severity. Activity of the glymphatic system may be evaluated with diffusion images. Lower diffusivity along the perivascular space on DTI-APLS seems to reflect impairment of the glymphatic system. This method may be useful for evaluating the activity of the glymphatic system.

  4. Contrasting brain patterns of writing-related DTI parameters, fMRI connectivity, and DTI–fMRI connectivity correlations in children with and without dysgraphia or dyslexia

    Science.gov (United States)

    Richards, T.L.; Grabowski, T.J.; Boord, P.; Yagle, K.; Askren, M.; Mestre, Z.; Robinson, P.; Welker, O.; Gulliford, D.; Nagy, W.; Berninger, V.

    2015-01-01

    Based on comprehensive testing and educational history, children in grades 4–9 (on average 12 years) were diagnosed with dysgraphia (persisting handwriting impairment) or dyslexia (persisting word spelling/reading impairment) or as typical writers and readers (controls). The dysgraphia group (n = 14) and dyslexia group (n = 17) were each compared to the control group (n = 9) and to each other in separate analyses. Four brain region seed points (left occipital temporal gyrus, supramarginal gyrus, precuneus, and inferior frontal gyrus) were used in these analyses which were shown in a metaanalysis to be related to written word production on four indicators of white matter integrity and fMRI functional connectivity for four tasks (self-guided mind wandering during resting state, writing letter that follows a visually displayed letter in alphabet, writing missing letter to create a correctly spelled real word, and planning for composing after scanning on topic specified by researcher). For those DTI indicators on which the dysgraphic group or dyslexic group differed from the control group (fractional anisotropy, relative anisotropy, axial diffusivity but not radial diffusivity), correlations were computed between the DTI parameter and fMRI functional connectivity for the two writing tasks (alphabet and spelling) by seed points. Analyses, controlled for multiple comparisons, showed that (a) the control group exhibited more white matter integrity than either the dysgraphic or dyslexic group; (b) the dysgraphic and dyslexic groups showed more functional connectivity than the control group but differed in patterns of functional connectivity for task and seed point; and (c) the dysgraphic and dyslexic groups showed different patterns of significant DTI–fMRI connectivity correlations for specific seed points and written language tasks. Thus, dysgraphia and dyslexia differ in white matter integrity, fMRI functional connectivity, and white matter–gray matter

  5. Contrasting brain patterns of writing-related DTI parameters, fMRI connectivity, and DTI–fMRI connectivity correlations in children with and without dysgraphia or dyslexia

    Directory of Open Access Journals (Sweden)

    T.L. Richards

    2015-01-01

    Full Text Available Based on comprehensive testing and educational history, children in grades 4–9 (on average 12 years were diagnosed with dysgraphia (persisting handwriting impairment or dyslexia (persisting word spelling/reading impairment or as typical writers and readers (controls. The dysgraphia group (n = 14 and dyslexia group (n = 17 were each compared to the control group (n = 9 and to each other in separate analyses. Four brain region seed points (left occipital temporal gyrus, supramarginal gyrus, precuneus, and inferior frontal gyrus were used in these analyses which were shown in a metaanalysis to be related to written word production on four indicators of white matter integrity and fMRI functional connectivity for four tasks (self-guided mind wandering during resting state, writing letter that follows a visually displayed letter in alphabet, writing missing letter to create a correctly spelled real word, and planning for composing after scanning on topic specified by researcher. For those DTI indicators on which the dysgraphic group or dyslexic group differed from the control group (fractional anisotropy, relative anisotropy, axial diffusivity but not radial diffusivity, correlations were computed between the DTI parameter and fMRI functional connectivity for the two writing tasks (alphabet and spelling by seed points. Analyses, controlled for multiple comparisons, showed that (a the control group exhibited more white matter integrity than either the dysgraphic or dyslexic group; (b the dysgraphic and dyslexic groups showed more functional connectivity than the control group but differed in patterns of functional connectivity for task and seed point; and (c the dysgraphic and dyslexic groups showed different patterns of significant DTI–fMRI connectivity correlations for specific seed points and written language tasks. Thus, dysgraphia and dyslexia differ in white matter integrity, fMRI functional connectivity, and white matter–gray matter

  6. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.

    Science.gov (United States)

    Malkyarenko, Dariya I; Chenevert, Thomas L

    2014-12-01

    To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.

  7. Gradient waveform synthesis for magnetic propulsion using MRI gradient coils

    International Nuclear Information System (INIS)

    Han, B H; Lee, S Y; Park, S

    2008-01-01

    Navigating an untethered micro device in a living subject is of great interest for both diagnostic and therapeutic applications. Magnetic propulsion of an untethered device carrying a magnetic core in it is one of the promising methods to navigate the device. MRI gradients coils are thought to be suitable for navigating the device since they are capable of magnetic propulsion in any direction while providing magnetic resonance images. For precise navigation of the device, especially in the peripheral region of the gradient coils, the concomitant gradient fields, as well as the linear gradient fields in the main magnetic field direction, should be considered in driving the gradient coils. For simple gradient coil configurations, the Maxwell coil in the z-direction and the Golay coil in the x- and y-directions, we have calculated the magnetic force fields, which are not necessarily the same as the conventional linear gradient fields of MRI. Using the calculated magnetic force fields, we have synthesized gradient waveforms to navigate the device along a desired path

  8. A preliminary DTI study showing no brain structural change associated with adolescent cannabis use

    Directory of Open Access Journals (Sweden)

    Brown Kyle

    2006-05-01

    Full Text Available Abstract Analyses were performed on brain MRI scans from individuals who were frequent cannabis users (N = 10; 9 males, 1 female, mean age 21.1 ± 2.9, range: 18–27 in adolescence and similar age and sex matched young adults who never used cannabis (N = 10; 9 males, 1 female, mean age of 23.0 ± 4.4, range: 17–30. Cerebral atrophy and white matter integrity were determined using diffusion tensor imaging (DTI to quantify the apparent diffusion coefficient (ADC and the fractional anisotropy (FA. Whole brain volumes, lateral ventricular volumes, and gray matter volumes of the amygdala-hippocampal complex, superior temporal gyrus, and entire temporal lobes (excluding the amygdala-hippocampal complex were also measured. While differences existed between groups, no pattern consistent with evidence of cerebral atrophy or loss of white matter integrity was detected. It is concluded that frequent cannabis use is unlikely to be neurotoxic to the normal developing adolescent brain.

  9. Combining Step Gradients and Linear Gradients in Density.

    Science.gov (United States)

    Kumar, Ashok A; Walz, Jenna A; Gonidec, Mathieu; Mace, Charles R; Whitesides, George M

    2015-06-16

    Combining aqueous multiphase systems (AMPS) and magnetic levitation (MagLev) provides a method to produce hybrid gradients in apparent density. AMPS—solutions of different polymers, salts, or surfactants that spontaneously separate into immiscible but predominantly aqueous phases—offer thermodynamically stable steps in density that can be tuned by the concentration of solutes. MagLev—the levitation of diamagnetic objects in a paramagnetic fluid within a magnetic field gradient—can be arranged to provide a near-linear gradient in effective density where the height of a levitating object above the surface of the magnet corresponds to its density; the strength of the gradient in effective density can be tuned by the choice of paramagnetic salt and its concentrations and by the strength and gradient in the magnetic field. Including paramagnetic salts (e.g., MnSO4 or MnCl2) in AMPS, and placing them in a magnetic field gradient, enables their use as media for MagLev. The potential to create large steps in density with AMPS allows separations of objects across a range of densities. The gradients produced by MagLev provide resolution over a continuous range of densities. By combining these approaches, mixtures of objects with large differences in density can be separated and analyzed simultaneously. Using MagLev to add an effective gradient in density also enables tuning the range of densities captured at an interface of an AMPS by simply changing the position of the container in the magnetic field. Further, by creating AMPS in which phases have different concentrations of paramagnetic ions, the phases can provide different resolutions in density. These results suggest that combining steps in density with gradients in density can enable new classes of separations based on density.

  10. Application of velocity imaging and gradient-recalled echo in neuroimaging

    International Nuclear Information System (INIS)

    Boyko, O.B.; Pelc, N.J.; Shimakawa, A.

    1990-01-01

    This paper describes the initial clinical experience with imaging blood flow at 1.5 T by means of a phase-sensitive gradient refocused pulse sequence. A spin-echo flow-encoding technique was modified to a gradient recalled acquisition in a steady state sequence, producing a velocity imaging and gradient recalled echo (VIGRE) sequence (TR = 24 msec, TE = 13 msec, flip angle = 45 degrees, 24-cm field of view, 7 mm contiguous sections). Two views per phase-encoding step are acquired; one using the first-moment flow-compensation gradient waveform and the second having a (selectable) nonzero first moment. A phase subtraction image is obtained where the signal is dependent on the direction and velocity of flow. The sequence was done following routine spin-echo imaging in 35 patients

  11. Momentum-weighted conjugate gradient descent algorithm for gradient coil optimization.

    Science.gov (United States)

    Lu, Hanbing; Jesmanowicz, Andrzej; Li, Shi-Jiang; Hyde, James S

    2004-01-01

    MRI gradient coil design is a type of nonlinear constrained optimization. A practical problem in transverse gradient coil design using the conjugate gradient descent (CGD) method is that wire elements move at different rates along orthogonal directions (r, phi, z), and tend to cross, breaking the constraints. A momentum-weighted conjugate gradient descent (MW-CGD) method is presented to overcome this problem. This method takes advantage of the efficiency of the CGD method combined with momentum weighting, which is also an intrinsic property of the Levenberg-Marquardt algorithm, to adjust step sizes along the three orthogonal directions. A water-cooled, 12.8 cm inner diameter, three axis torque-balanced gradient coil for rat imaging was developed based on this method, with an efficiency of 2.13, 2.08, and 4.12 mT.m(-1).A(-1) along X, Y, and Z, respectively. Experimental data demonstrate that this method can improve efficiency by 40% and field uniformity by 27%. This method has also been applied to the design of a gradient coil for the human brain, employing remote current return paths. The benefits of this design include improved gradient field uniformity and efficiency, with a shorter length than gradient coil designs using coaxial return paths. Copyright 2003 Wiley-Liss, Inc.

  12. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Bhat, Himanshu; Runge, Val M; Guggenberger, Roman

    2016-06-01

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

  13. Limbic-thalamo-cortical projections and reward-related circuitry integrity affects eating behavior: A longitudinal DTI study in adolescents with restrictive eating disorders.

    Directory of Open Access Journals (Sweden)

    Gaia Olivo

    Full Text Available Few studies have used diffusion tensor imaging (DTI to investigate the micro-structural alterations of WM in patients with restrictive eating disorders (rED, and longitudinal data are lacking. Twelve patients with rED were scanned at diagnosis and after one year of family-based treatment, and compared to twenty-four healthy controls (HCs through DTI analysis. A tract-based spatial statistics procedure was used to investigate diffusivity parameters: fractional anisotropy (FA and mean, radial and axial diffusivities (MD, RD and AD, respectively. Reduced FA and increased RD were found in patients at baseline in the corpus callosum, corona radiata and posterior thalamic radiation compared with controls. However, no differences were found between follow-up patients and controls, suggesting a partial normalization of the diffusivity parameters. In patients, trends for a negative correlation were found between the baseline FA of the right anterior corona radiata and the Eating Disorder Examination Questionnaire total score, while a positive trend was found between the baseline FA in the splenium of corpus callosum and the weight loss occurred between maximal documented weight and time of admission. A positive trend for correlation was also found between baseline FA in the right anterior corona radiata and the decrease in the Obsessive-Compulsive Inventory Revised total score over time. Our results suggest that the integrity of the limbic-thalamo-cortical projections and the reward-related circuitry are important for cognitive control processes and reward responsiveness in regulating eating behavior.

  14. Full magnetic gradient tensor from triaxial aeromagnetic gradient measurements: Calculation and application

    Science.gov (United States)

    Luo, Yao; Wu, Mei-Ping; Wang, Ping; Duan, Shu-Ling; Liu, Hao-Jun; Wang, Jin-Long; An, Zhan-Feng

    2015-09-01

    The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mapping, resources exploration, magnetic navigation, and others. However, it is very difficult to measure the full magnetic tensor gradient using existing engineering technology. We present a method to use triaxial aeromagnetic gradient measurements for deriving the full MGT. The method uses the triaxial gradient data and makes full use of the variation of the magnetic anomaly modulus in three dimensions to obtain a self-consistent magnetic tensor gradient. Numerical simulations show that the full MGT data obtained with the proposed method are of high precision and satisfy the requirements of data processing. We selected triaxial aeromagnetic gradient data from the Hebei Province for calculating the full MGT. Data processing shows that using triaxial tensor gradient data allows to take advantage of the spatial rate of change of the total field in three dimensions and suppresses part of the independent noise in the aeromagnetic gradient. The calculated tensor components have improved resolution, and the transformed full tensor gradient satisfies the requirement of geological mapping and interpretation.

  15. Fractional anisotropy and diffusivity changes in thyroid-associated orbitopathy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Ji Sung; Seo, Hyung Suk; Lee, Young Hen [Korea University Ansan Hospital, Department of Radiology, Ansan, Gyeonggido (Korea, Republic of); Lee, Hwa [Korea University Ansan Hospital, Department of Ophthalmology, Ansan (Korea, Republic of); Suh, Sang-il [Korea University Guro Hospital, Department of Radiology, Seoul (Korea, Republic of); Jeong, Eun-Kee; Sapkota, Nabraj [University of Utah, Utah Center for Advanced Imaging Research, Salt Lake City, UT (United States); Kim, Ki Joon [Nanoori Hospital, Department of Neurosurgery, Seoul (Korea, Republic of)

    2016-12-15

    To investigate the extraocular muscle (EOM) changes in thyroid-associated orbitopathy (TAO) on DTI and the correlations between DTI parameters and clinical features. Twenty TAO patients and 20 age- and sex-matched controls provided informed consent and were enrolled. Ten-directional DTI was acquired in orbit. Fractional anisotropy (FA), mean, axial, and radial diffusivities were obtained at medial and lateral EOMs in both orbits. EOM thickness was measured in patients using axial CT images. FA and diffusivities were compared between patients and controls. The relationships between DTI values and muscle thickness and exophthalmos were evaluated. DTI values compared between patients in active and inactive phases by clinical activity score of TAO. DTI values were also compared between acute and chronic stages by the duration of disease. In medial EOM, FA was significantly lower in patients (p < 0.001) and negatively correlated with muscle thickness (r = -0.604, p < 0.001). Radial diffusivity was significantly higher in patients (p = 0.010) and correlated with muscle thickness (r = 0.349, p = 0.027). In lateral EOM, DTI values did not differ between patients and controls. In the acute stage, the diffusivities of the medial rectus EOM were increased compared with the chronic stage. DTI values of the medial and lateral rectus EOM did not differ significantly between active and inactive phases. DTI can be used to diagnose TAO with FA and radial diffusivity change in EOM. Diffusivities can be used to differentiate acute and chronic stage of TAO. However, DTI values showed limitation in reflecting TAO activity according to the CAS. (orig.)

  16. The Effects of Synthetic Cannabinoids on Alveolar-Arterial Oxygen Gradient

    Directory of Open Access Journals (Sweden)

    Egemen Kucuk

    2016-09-01

    Full Text Available Aim: Synthetic cannabinoids are chemicals that produce several marijuana-like effects in humans. Aim of this study is to investigate the effects of synthetic cannabinoids on to alveolar-arterial oxygen gradient. Material and Method: A total of 112 patients, who admitted directly to emergency clinic with synthetic cannabinoid usage, were determined between February 2014 and August 2014. Blood gases of 41 patients were determined as arterial blood gases on room air, and included in to study. Patients were evaluated according to age, sex, decade, partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, pH, bicarbonate, metabolic status, age consistent expected alveolar-arterial oxygen gradient and calculated alveolar-arterial oxygen gradient. Results: Synthetic cannabinoid using was higher in males, mean age of patients was 23.32±6.14 years. Number of patients in the third decade were significantly higher than the other decades. The calculated alveolar-arterial oxygen gradient value of patients was significantly higher than age consistent expected alveolar-arterial oxygen gradient value. Respiratory acidosis, was significantly higher than the other types of the metabolic disorders. The best cutoff point for calculated alveolar-arterial oxygen gradient was 12.70, with sensitivity of 90% and specifity of 85%. Area under curve was 0.70 for calculated alveolar-arterial oxygen gradient. Discussion: The value of alveolar-arterial oxygen gradient has been increased due to synthetic cannabinoid usage. This can be used as a supportive parameter in the diagnosis of synthetic cannabinoid usage.

  17. The semantic variant of primary progressive aphasia: clinical and neuroimaging evidence in single subjects.

    Directory of Open Access Journals (Sweden)

    Leonardo Iaccarino

    Full Text Available We present a clinical-neuroimaging study in a series of patients with a clinical diagnosis of semantic variant of primary progressive aphasia (svPPA, with the aim to provide clinical-functional correlations of the cognitive and behavioral manifestations at the single-subject level.We performed neuropsychological investigations, 18F-FDG-PET single-subject and group analysis, with an optimized SPM voxel-based approach, and correlation analyses. A measurement of white matter integrity by means of diffusion tensor imaging (DTI was also available for a subgroup of patients.Cognitive assessment confirmed the presence of typical semantic memory deficits in all patients, with a relative sparing of executive, attentional, visuo-constructional, and episodic memory domains. 18F-FDG-PET showed a consistent pattern of cerebral hypometabolism across all patients, which correlated with performance in semantic memory tasks. In addition, a majority of patients also presented with behavioral disturbances associated with metabolic dysfunction in limbic structures. In a subgroup of cases the DTI analysis showed FA abnormalities in the inferior longitudinal and uncinate fasciculi.Each svPPA individual had functional derangement involving an extended, connected system within the left temporal lobe, a crucial part of the verbal semantic network, as well as an involvement of limbic structures. The latter was associated with behavioral manifestations and extended beyond the area of atrophy shown by CT scan.Single-subject 18F-FDG-PET analysis can account for both cognitive and behavioral alterations in svPPA. This provides useful support to the clinical diagnosis.

  18. Rank gradient and p-gradient of amalgamated free products and HNN extensions

    OpenAIRE

    Pappas, Nathaniel

    2013-01-01

    We calculate the rank gradient and p-gradient of free products, free products with amalgamation over an amenable subgroup, and HNN extensions with an amenable associated subgroup. The notion of cost is used to compute the rank gradient of amalgamated free products and HNN extensions. For the p-gradient the Kurosh subgroup theorems for amalgamated free products and HNN extensions will be used.

  19. Right is not always wrong: DTI and fMRI evidence for the reliance of reading comprehension on language-comprehension networks in the right hemisphere.

    Science.gov (United States)

    Horowitz-Kraus, Tzipi; Grainger, Molly; DiFrancesco, Mark; Vannest, Jennifer; Holland, Scott K

    2015-03-01

    The Simple View theory suggests that reading comprehension relies on automatic recognition of words combined with language comprehension. The goal of the current study was to examine the structural and functional connectivity in networks supporting reading comprehension and their relationship with language comprehension within 7-9 year old children using Diffusion Tensor Imaging (DTI) and fMRI during a Sentence Picture Matching task. Fractional Anisotropy (FA) values in the left and right Inferior Longitudinal Fasciculus (ILF) and Superior Longitudinal Fasciculus (SLF), known language-related tracts, were correlated from DTI data with scores from the Woodcock-Johnson III (WJ-III) Passage Comprehension sub-test. Brodmann areas most proximal to white-matter regions with significant correlation to Passage Comprehension scores were chosen as Regions-of-Interest (ROIs) and used as seeds in a functional connectivity analysis using the Sentence Picture Matching task. The correlation between percentile scores for the WJ-III Passage Comprehension subtest and the FA values in the right and left ILF and SLF indicated positive correlation in language-related ROIs, with greater distribution in the right hemisphere, which in turn showed strong connectivity in the fMRI data from the Sentence Picture Matching task. These results support the participation of the right hemisphere in reading comprehension and may provide physiologic support for a distinction between different types of reading comprehension deficits vs difficulties in technical reading.

  20. Diffusion Tensor Imaging: Application to the Study of the Developing Brain

    Science.gov (United States)

    Cascio, Carissa J.; Gerig, Guido; Piven, Joseph

    2007-01-01

    Objective: To provide an overview of diffusion tensor imaging (DTI) and its application to the study of white matter in the developing brain in both healthy and clinical samples. Method: The development of DTI and its application to brain imaging of white matter tracts is discussed. Forty-eight studies using DTI to examine diffusion properties of…

  1. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Runge, Val M.; Guggenberger, Roman [University Hospital of Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Piccirelli, Marco [University Hospital of Zurich, Department of Neuroradiology, Zurich (Switzerland); Bhat, Himanshu [Siemens Medical Solutions USA Inc, Charlestown, MA (United States)

    2016-06-15

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm{sup 2}; 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm{sup 2}/s; twofold acceleration: 1.016 ± 0.123 mm{sup 2}/s; threefold acceleration: 0.979 ± 0.153 mm{sup 2}/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. (orig.)

  2. Combination of DTI and fMRI reveals the white matter changes correlating with the decline of default-mode network activity in Alzheimer's disease

    Science.gov (United States)

    Wu, Xianjun; Di, Qian; Li, Yao; Zhao, Xiaojie

    2009-02-01

    Recently, evidences from fMRI studies have shown that there was decreased activity among the default-mode network in Alzheimer's disease (AD), and DTI researches also demonstrated that demyelinations exist in white matter of AD patients. Therefore, combining these two MRI methods may help to reveal the relationship between white matter damages and alterations of the resting state functional connectivity network. In the present study, we tried to address this issue by means of correlation analysis between DTI and resting state fMRI images. The default-mode networks of AD and normal control groups were compared to find the areas with significantly declined activity firstly. Then, the white matter regions whose fractional anisotropy (FA) value correlated with this decline were located through multiple regressions between the FA values and the BOLD response of the default networks. Among these correlating white matter regions, those whose FA values also declined were found by a group comparison between AD patients and healthy elderly control subjects. Our results showed that the areas with decreased activity among default-mode network included left posterior cingulated cortex (PCC), left medial temporal gyrus et al. And the damaged white matter areas correlated with the default-mode network alterations were located around left sub-gyral temporal lobe. These changes may relate to the decreased connectivity between PCC and medial temporal lobe (MTL), and thus correlate with the deficiency of default-mode network activity.

  3. The clinical and imaging characteristics of delayed encephalopathy after acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Huang Chuming; Yin Zhao; Fang Yannan; Hong Weimin; Zeng Xianjie; Wang Tianwen

    2008-01-01

    Objective: To discuss the clinical and imaging characteristics of delayed encephalopathy after acute carbon monoxide poisoning (DEACMP). Methods: The clinical data of 14 patients with DEACMP were respectively analyzed. Results: Initial symptom included mentally falling (MMSE rate < 20 points) in 14 patients (100%), incontinence of urine in 11 patients (78%). Relatively significant increase of hematoma (HCT) (average level 0.503±0.027) was found in 6 patients. Three kinds of brain magnetic resonance imaging (MRI) appearance including diffuse white matter lesion, cortical lesion and basal nuclei lesion often existed in association. Therapy for improving circulation was given in 14 patients, and therapy with hormone was given in 9 patients; with 85% improvement rate. 5 patients without hormone therapy but with improving circulation therapy also received improvement. Conclusion: High level of HCT might be one of the causes of DECACMP due to acute disturbance of brain micro-circulation.. Close monitoring the change of HCT levels should be adopted for at least 3-6 months during therapy. Therapy for improving circulation and for anti-agglutination of platelets should be performed besides the routine high-tension oxygen therapy. Low FA value on DTI indicates the occurrence of a demyelization change in the brain long tract fibers, which indicated therapeutic effect of hormone treatment. And, therefore it would be better to perform DTI scan before therapy for individualized therapy. (authors)

  4. Graph Theory-Based Brain Connectivity for Automatic Classification of Multiple Sclerosis Clinical Courses

    Directory of Open Access Journals (Sweden)

    Gabriel Kocevar

    2016-10-01

    Full Text Available Purpose: In this work, we introduce a method to classify Multiple Sclerosis (MS patients into four clinical profiles using structural connectivity information. For the first time, we try to solve this question in a fully automated way using a computer-based method. The main goal is to show how the combination of graph-derived metrics with machine learning techniques constitutes a powerful tool for a better characterization and classification of MS clinical profiles.Materials and methods: Sixty-four MS patients (12 Clinical Isolated Syndrome (CIS, 24 Relapsing Remitting (RR, 24 Secondary Progressive (SP, and 17 Primary Progressive (PP along with 26 healthy controls (HC underwent MR examination. T1 and diffusion tensor imaging (DTI were used to obtain structural connectivity matrices for each subject. Global graph metrics, such as density and modularity, were estimated and compared between subjects’ groups. These metrics were further used to classify patients using tuned Support Vector Machine (SVM combined with Radial Basic Function (RBF kernel.Results: When comparing MS patients to HC subjects, a greater assortativity, transitivity and characteristic path length as well as a lower global efficiency were found. Using all graph metrics, the best F-Measures (91.8%, 91.8%, 75.6% and 70.6% were obtained for binary (HC-CIS, CIS-RR, RR-PP and multi-class (CIS-RR-SP classification tasks, respectively. When using only one graph metric, the best F-Measures (83.6%, 88.9% and 70.7% were achieved for modularity with previous binary classification tasks.Conclusion: Based on a simple DTI acquisition associated with structural brain connectivity analysis, this automatic method allowed an accurate classification of different MS patients’ clinical profiles.

  5. The neuroanatomy of subthreshold depressive symptoms in Huntington's disease: a combined diffusion tensor imaging (DTI) and voxel-based morphometry (VBM) study.

    Science.gov (United States)

    Sprengelmeyer, R; Orth, M; Müller, H-P; Wolf, R C; Grön, G; Depping, M S; Kassubek, J; Justo, D; Rees, E M; Haider, S; Cole, J H; Hobbs, N Z; Roos, R A C; Dürr, A; Tabrizi, S J; Süssmuth, S D; Landwehrmeyer, G B

    2014-07-01

    Depressive symptoms are prominent psychopathological features of Huntington's disease (HD), making a negative impact on social functioning and well-being. We compared the frequencies of a history of depression, previous suicide attempts and current subthreshold depression between 61 early-stage HD participants and 40 matched controls. The HD group was then split based on the overall HD group's median Hospital Anxiety and Depression Scale-depression score into a group of 30 non-depressed participants (mean 0.8, s.d. = 0.7) and a group of 31 participants with subthreshold depressive symptoms (mean 7.3, s.d. = 3.5) to explore the neuroanatomy underlying subthreshold depressive symptoms in HD using voxel-based morphometry (VBM) and diffusion tensor imaging (DTI). Frequencies of history of depression, previous suicide attempts or current subthreshold depressive symptoms were higher in HD than in controls. The severity of current depressive symptoms was also higher in HD, but not associated with the severity of HD motor signs or disease burden. Compared with the non-depressed HD group DTI revealed lower fractional anisotropy (FA) values in the frontal cortex, anterior cingulate cortex, insula and cerebellum of the HD group with subthreshold depressive symptoms. In contrast, VBM measures were similar in both HD groups. A history of depression, the severity of HD motor signs or disease burden did not correlate with FA values of these regions. Current subthreshold depressive symptoms in early HD are associated with microstructural changes - without concomitant brain volume loss - in brain regions known to be involved in major depressive disorder, but not those typically associated with HD pathology.

  6. Active brain changes after initiating fingolimod therapy in multiple sclerosis patients using individual voxel-based analyses for diffusion tensor imaging.

    Science.gov (United States)

    Senda, Joe; Watanabe, Hirohisa; Endo, Kuniyuki; Yasui, Keizo; Hawsegawa, Yasuhiro; Yoneyama, Noritaka; Tsuboi, Takashi; Hara, Kazuhiro; Ito, Mizuki; Atsuta, Naoki; Epifanio, Bagarinao; Katsuno, Masahisa; Naganawa, Shinji; Sobue, Gen

    2016-12-01

    Voxel-based analysis (VBA) of diffusion tensor images (DTI) and voxel-based morphometry (VBM) in patients with multiple sclerosis (MS) can sensitively detect occult tissue damage that underlies pathological changes in the brain. In the present study, both at the start of fingolimod and post-four months clinical remission, we assessed four patients with MS who were evaluated with VBA of DTI, VBM, and fluid-attenuated inversion recovery (FLAIR). DTI images for all four patients showed widespread areas of increased mean diffusivity (MD) and decreased fractional anisotropy (FA) that were beyond the high-intensity signal areas across images. After four months of continuous fingolimod therapy, DTI abnormalities progressed; in particular, MD was significantly increased, while brain volume and high-intensity signals were unchanged. These findings suggest that VBA of DTI (e.g., MD) may help assess MS demyelination as neuroinflammatory conditions, even though clinical manifestations of MS appear to be in complete remission during fingolimod.

  7. Dai-Kou type conjugate gradient methods with a line search only using gradient.

    Science.gov (United States)

    Huang, Yuanyuan; Liu, Changhe

    2017-01-01

    In this paper, the Dai-Kou type conjugate gradient methods are developed to solve the optimality condition of an unconstrained optimization, they only utilize gradient information and have broader application scope. Under suitable conditions, the developed methods are globally convergent. Numerical tests and comparisons with the PRP+ conjugate gradient method only using gradient show that the methods are efficient.

  8. In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR Diffusion Tensor Imaging

    International Nuclear Information System (INIS)

    Panebianco, Valeria; Barchetti, Flavio; Sciarra, Alessandro; Marcantonio, Andrea; Zini, Chiara; Salciccia, Stefano; Collettini, Federico; Gentile, Vincenzo; Hamm, Bernard; Catalano, Carlo

    2013-01-01

    Objectives: To evaluate if Diffusion Tensor Imaging technique (DTI) can improve the visualization of periprostatic nerve fibers describing the location and distribution of entire neurovascular plexus around the prostate in patients who are candidates for prostatectomy. Materials and methods: Magnetic Resonance Imaging (MRI), including a 2D T2-weighted FSE sequence in 3 planes, 3D T2-weighted and DTI using 16 gradient directions and b = 0 and 1000, was performed on 36 patients. Three out of 36 patients were excluded from the analysis due to poor image quality (blurring N = 2, artifact N = 1). The study was approved by local ethics committee and all patients gave an informed consent. Images were evaluated by two radiologists with different experience in MRI. DTI images were analyzed qualitatively using dedicated software. Also 2D and 3D T2 images were independently considered. Results: 3D-DTI allowed description of the entire plexus of the periprostatic nerve fibers in all directions, while 2D and 3D T2 morphological sequences depicted part of the fibers, in a plane by plane analysis of fiber courses. DTI demonstrated in all patients the dispersion of nerve fibers around the prostate on both sides including the significant percentage present in the anterior and anterolateral sectors. Conclusions: DTI offers optimal representation of the widely distributed periprostatic plexus. If validated, it may help guide nerve-sparing radical prostatectomy

  9. Accelerated gradient methods for total-variation-based CT image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Joergensen, Jakob H.; Hansen, Per Christian [Technical Univ. of Denmark, Lyngby (Denmark). Dept. of Informatics and Mathematical Modeling; Jensen, Tobias L.; Jensen, Soeren H. [Aalborg Univ. (Denmark). Dept. of Electronic Systems; Sidky, Emil Y.; Pan, Xiaochuan [Chicago Univ., Chicago, IL (United States). Dept. of Radiology

    2011-07-01

    Total-variation (TV)-based CT image reconstruction has shown experimentally to be capable of producing accurate reconstructions from sparse-view data. In particular TV-based reconstruction is well suited for images with piecewise nearly constant regions. Computationally, however, TV-based reconstruction is demanding, especially for 3D imaging, and the reconstruction from clinical data sets is far from being close to real-time. This is undesirable from a clinical perspective, and thus there is an incentive to accelerate the solution of the underlying optimization problem. The TV reconstruction can in principle be found by any optimization method, but in practice the large scale of the systems arising in CT image reconstruction preclude the use of memory-intensive methods such as Newton's method. The simple gradient method has much lower memory requirements, but exhibits prohibitively slow convergence. In the present work we address the question of how to reduce the number of gradient method iterations needed to achieve a high-accuracy TV reconstruction. We consider the use of two accelerated gradient-based methods, GPBB and UPN, to solve the 3D-TV minimization problem in CT image reconstruction. The former incorporates several heuristics from the optimization literature such as Barzilai-Borwein (BB) step size selection and nonmonotone line search. The latter uses a cleverly chosen sequence of auxiliary points to achieve a better convergence rate. The methods are memory efficient and equipped with a stopping criterion to ensure that the TV reconstruction has indeed been found. An implementation of the methods (in C with interface to Matlab) is available for download from http://www2.imm.dtu.dk/~pch/TVReg/. We compare the proposed methods with the standard gradient method, applied to a 3D test problem with synthetic few-view data. We find experimentally that for realistic parameters the proposed methods significantly outperform the standard gradient method. (orig.)

  10. MODIFIED ARMIJO RULE ON GRADIENT DESCENT AND CONJUGATE GRADIENT

    Directory of Open Access Journals (Sweden)

    ZURAIDAH FITRIAH

    2017-10-01

    Full Text Available Armijo rule is an inexact line search method to determine step size in some descent method to solve unconstrained local optimization. Modified Armijo was introduced to increase the numerical performance of several descent algorithms that applying this method. The basic difference of Armijo and its modified are in existence of a parameter and estimating the parameter that is updated in every iteration. This article is comparing numerical solution and time of computation of gradient descent and conjugate gradient hybrid Gilbert-Nocedal (CGHGN that applying modified Armijo rule. From program implementation in Matlab 6, it's known that gradient descent was applying modified Armijo more effectively than CGHGN from one side: iteration needed to reach some norm of the gradient  (input by the user. The amount of iteration was representing how long the step size of each algorithm in each iteration. In another side, time of computation has the same conclusion.

  11. Ternary gradient metal-organic frameworks.

    Science.gov (United States)

    Liu, Chong; Rosi, Nathaniel L

    2017-09-08

    Gradient MOFs contain directional gradients of either structure or functionality. We have successfully prepared two ternary gradient MOFs based on bMOF-100 analogues, namely bMOF-100/102/106 and bMOF-110/100/102, via cascade ligand exchange reactions. The cubic unit cell parameter discrepancy within an individual ternary gradient MOF crystal is as large as ∼1 nm, demonstrating the impressive compatibility and flexibility of the component MOF materials. Because of the presence of a continuum of unit cells, the pore diameters within individual crystals also change in a gradient fashion from ∼2.5 nm to ∼3.0 nm for bMOF-100/102/106, and from ∼2.2 nm to ∼2.7 nm for bMOF-110/100/102, indicating significant porosity gradients. Like previously reported binary gradient MOFs, the composition of the ternary gradient MOFs can be easily controlled by adjusting the reaction conditions. Finally, X-ray diffraction and microspectrophotometry were used to analyse fractured gradient MOF crystals by comparing unit cell parameters and absorbance spectra at different locations, thus revealing the profile of heterogeneity (i.e. gradient distribution of properties) and further confirming the formation of ternary gradient MOFs.

  12. Evaluation of glymphatic system activity with the diffusion MR technique: diffusion tensor image analysis along the perivascular space (DTI-ALPS) in Alzheimer’s disease cases

    OpenAIRE

    Taoka, Toshiaki; Masutani, Yoshitaka; Kawai, Hisashi; Nakane, Toshiki; Matsuoka, Kiwamu; Yasuno, Fumihiko; Kishimoto, Toshifumi; Naganawa, Shinji

    2017-01-01

    Purpose: The activity of the glymphatic system is impaired in animal models of Alzheimer’s disease (AD). We evaluated the activity of the human glymphatic system in cases of AD with a diffusion-based technique called diffusion tensor image analysis along the perivascular space (DTI-ALPS). Materials and methods: Diffusion tensor images were acquired to calculate diffusivities in the x, y, and z axes of the plane of the lateral ventricle body in 31 patients. We evaluated the diffusivity along t...

  13. $L_{0}$ Gradient Projection.

    Science.gov (United States)

    Ono, Shunsuke

    2017-04-01

    Minimizing L 0 gradient, the number of the non-zero gradients of an image, together with a quadratic data-fidelity to an input image has been recognized as a powerful edge-preserving filtering method. However, the L 0 gradient minimization has an inherent difficulty: a user-given parameter controlling the degree of flatness does not have a physical meaning since the parameter just balances the relative importance of the L 0 gradient term to the quadratic data-fidelity term. As a result, the setting of the parameter is a troublesome work in the L 0 gradient minimization. To circumvent the difficulty, we propose a new edge-preserving filtering method with a novel use of the L 0 gradient. Our method is formulated as the minimization of the quadratic data-fidelity subject to the hard constraint that the L 0 gradient is less than a user-given parameter α . This strategy is much more intuitive than the L 0 gradient minimization because the parameter α has a clear meaning: the L 0 gradient value of the output image itself, so that one can directly impose a desired degree of flatness by α . We also provide an efficient algorithm based on the so-called alternating direction method of multipliers for computing an approximate solution of the nonconvex problem, where we decompose it into two subproblems and derive closed-form solutions to them. The advantages of our method are demonstrated through extensive experiments.

  14. Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

    Science.gov (United States)

    Tao, Shengzhen; Weavers, Paul T; Trzasko, Joshua D; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M; Bernstein, Matt A

    2017-06-01

    To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Gradient waveform pre-emphasis based on the gradient system transfer function.

    Science.gov (United States)

    Stich, Manuel; Wech, Tobias; Slawig, Anne; Ringler, Ralf; Dewdney, Andrew; Greiser, Andreas; Ruyters, Gudrun; Bley, Thorsten A; Köstler, Herbert

    2018-02-25

    The gradient system transfer function (GSTF) has been used to describe the distorted k-space trajectory for image reconstruction. The purpose of this work was to use the GSTF to determine the pre-emphasis for an undistorted gradient output and intended k-space trajectory. The GSTF of the MR system was determined using only standard MR hardware without special equipment such as field probes or a field camera. The GSTF was used for trajectory prediction in image reconstruction and for a gradient waveform pre-emphasis. As test sequences, a gradient-echo sequence with phase-encoding gradient modulation and a gradient-echo sequence with a spiral read-out trajectory were implemented and subsequently applied on a structural phantom and in vivo head measurements. Image artifacts were successfully suppressed by applying the GSTF-based pre-emphasis. Equivalent results are achieved with images acquired using GSTF-based post-correction of the trajectory as a part of image reconstruction. In contrast, the pre-emphasis approach allows reconstruction using the initially intended trajectory. The artifact suppression shown for two sequences demonstrates that the GSTF can serve for a novel pre-emphasis. A pre-emphasis based on the GSTF information can be applied to any arbitrary sequence type. © 2018 International Society for Magnetic Resonance in Medicine.

  16. Structural and functional abnormalities of default mode network in minimal hepatic encephalopathy: a study combining DTI and fMRI.

    Directory of Open Access Journals (Sweden)

    Rongfeng Qi

    Full Text Available BACKGROUND AND PURPOSE: Live failure can cause brain edema and aberrant brain function in cirrhotic patients. In particular, decreased functional connectivity within the brain default-mode network (DMN has been recently reported in overt hepatic encephalopathy (HE patients. However, so far, little is known about the connectivity among the DMN in the minimal HE (MHE, the mildest form of HE. Here, we combined diffusion tensor imaging (DTI and resting-state functional MRI (rs-fMRI to test our hypothesis that both structural and functional connectivity within the DMN were disturbed in MHE. MATERIALS AND METHODS: Twenty MHE patients and 20 healthy controls participated in the study. We explored the changes of structural (path length, tracts count, fractional anisotropy [FA] and mean diffusivity [MD] derived from DTI tractography and functional (temporal correlation coefficient derived from rs-fMRI connectivity of the DMN in MHE patients. Pearson correlation analysis was performed between the structural/functional indices and venous blood ammonia levels/neuropsychological tests scores of patients. All thresholds were set at P<0.05, Bonferroni corrected. RESULTS: Compared to the healthy controls, MHE patients showed both decreased FA and increased MD in the tract connecting the posterior cingulate cortex/precuneus (PCC/PCUN to left parahippocampal gyrus (PHG, and decreased functional connectivity between the PCC/PCUN and left PHG, and medial prefrontal cortex (MPFC. MD values of the tract connecting PCC/PCUN to the left PHG positively correlated to the ammonia levels, the temporal correlation coefficients between the PCC/PCUN and the MPFC showed positive correlation to the digital symbol tests scores of patients. CONCLUSION: MHE patients have both disturbed structural and functional connectivity within the DMN. The decreased functional connectivity was also detected between some regions without abnormal structural connectivity, suggesting that the

  17. Left hemisphere fractional anisotropy increase in noise-induced tinnitus: a diffusion tensor imaging (DTI) study of white matter tracts in the brain.

    Science.gov (United States)

    Benson, Randall R; Gattu, Ramtilak; Cacace, Anthony T

    2014-03-01

    Diffusion tensor imaging (DTI) is a contemporary neuroimaging modality used to study connectivity patterns and microstructure of white matter tracts in the brain. The use of DTI in the study of tinnitus is a relatively unexplored methodology with no studies focusing specifically on tinnitus induced by noise exposure. In this investigation, participants were two groups of adults matched for etiology, age, and degree of peripheral hearing loss, but differed by the presence or absence (+/-) of tinnitus. It is assumed that matching individuals on the basis of peripheral hearing loss, allows for differentiating changes in white matter microstructure due to hearing loss from changes due to the effects of chronic tinnitus. Alterations in white matter tracts, using the fractional anisotropy (FA) metric, which measures directional diffusion of water, were quantified using tract-based spatial statistics (TBSS) with additional details provided by in vivo probabilistic tractography. Our results indicate that 10 voxel clusters differentiated the two groups, including 9 with higher FA in the group with tinnitus. A decrease in FA was found for a single cluster in the group with tinnitus. However, seven of the 9 clusters with higher FA were in left hemisphere thalamic, frontal, and parietal white matter. These foci were localized to the anterior thalamic radiations and the inferior and superior longitudinal fasciculi. The two right-sided clusters with increased FA were located in the inferior fronto-occipital fasciculus and superior longitudinal fasciculus. The only decrease in FA for the tinnitus-positive group was found in the superior longitudinal fasciculus of the left parietal lobe. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Neonatal physiological correlates of near-term brain development on MRI and DTI in very-low-birth-weight preterm infants.

    Science.gov (United States)

    Rose, Jessica; Vassar, Rachel; Cahill-Rowley, Katelyn; Stecher Guzman, Ximena; Hintz, Susan R; Stevenson, David K; Barnea-Goraly, Naama

    2014-01-01

    Structural brain abnormalities identified at near-term age have been recognized as potential predictors of neurodevelopment in children born preterm. The aim of this study was to examine the relationship between neonatal physiological risk factors and early brain structure in very-low-birth-weight (VLBW) preterm infants using structural MRI and diffusion tensor imaging (DTI) at near-term age. Structural brain MRI, diffusion-weighted scans, and neonatal physiological risk factors were analyzed in a cross-sectional sample of 102 VLBW preterm infants (BW ≤ 1500 g, gestational age (GA) ≤ 32 weeks), who were admitted to the Lucile Packard Children's Hospital, Stanford NICU and recruited to participate prior to routine near-term brain MRI conducted at 36.6 ± 1.8 weeks postmenstrual age (PMA) from 2010 to 2011; 66/102 also underwent a diffusion-weighted scan. Brain abnormalities were assessed qualitatively on structural MRI, and white matter (WM) microstructure was analyzed quantitatively on DTI in six subcortical regions defined by DiffeoMap neonatal brain atlas. Specific regions of interest included the genu and splenium of the corpus callosum, anterior and posterior limbs of the internal capsule, the thalamus, and the globus pallidus. Regional fractional anisotropy (FA) and mean diffusivity (MD) were calculated using DTI data and examined in relation to neonatal physiological risk factors including gestational age (GA), bronchopulmonary dysplasia (BPD), necrotizing enterocolitis (NEC), retinopathy of prematurity (ROP), and sepsis, as well as serum levels of C-reactive protein (CRP), glucose, albumin, and total bilirubin. Brain abnormalities were observed on structural MRI in 38/102 infants including 35% of females and 40% of males. Infants with brain abnormalities observed on MRI had higher incidence of BPD (42% vs. 25%) and sepsis (21% vs. 6%) and higher mean and peak serum CRP levels, respectively, (0.64 vs. 0.34 mg/dL, p = .008; 1.57 vs. 0.67

  19. Magnetoelectric Transverse Gradient Sensor with High Detection Sensitivity and Low Gradient Noise.

    Science.gov (United States)

    Zhang, Mingji; Or, Siu Wing

    2017-10-25

    We report, theoretically and experimentally, the realization of a high detection performance in a novel magnetoelectric (ME) transverse gradient sensor based on the large ME effect and the magnetic field gradient (MFG) technique in a pair of magnetically-biased, electrically-shielded, and mechanically-enclosed ME composites having a transverse orientation and an axial separation. The output voltage of the gradient sensor is directly obtained from the transverse MFG-induced difference in ME voltage between the two ME composites and is calibrated against transverse MFGs to give a high detection sensitivity of 0.4-30.6 V/(T/m), a strong common-mode magnetic field noise rejection rate of gradient noise of 0.16-620 nT/m/ Hz in a broad frequency range of 1 Hz-170 kHz under a small baseline of 35 mm. An analysis of experimental gradient noise spectra obtained in a magnetically-unshielded laboratory environment reveals the domination of the pink (1/ f ) noise, dielectric loss noise, and power-frequency noise below 3 kHz, in addition to the circuit noise above 3 kHz, in the gradient sensor. The high detection performance, together with the added merit of passive and direct ME conversion by the large ME effect in the ME composites, makes the gradient sensor suitable for the passive, direct, and broadband detection of transverse MFGs.

  20. Wetting of flat gradient surfaces.

    Science.gov (United States)

    Bormashenko, Edward

    2018-04-01

    Gradient, chemically modified, flat surfaces enable directed transport of droplets. Calculation of apparent contact angles inherent for gradient surfaces is challenging even for atomically flat ones. Wetting of gradient, flat solid surfaces is treated within the variational approach, under which the contact line is free to move along the substrate. Transversality conditions of the variational problem give rise to the generalized Young equation valid for gradient solid surfaces. The apparent (equilibrium) contact angle of a droplet, placed on a gradient surface depends on the radius of the contact line and the values of derivatives of interfacial tensions. The linear approximation of the problem is considered. It is demonstrated that the contact angle hysteresis is inevitable on gradient surfaces. Electrowetting of gradient surfaces is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Regional vulnerability of longitudinal cortical association connectivity: Associated with structural network topology alterations in preterm children with cerebral palsy.

    Science.gov (United States)

    Ceschin, Rafael; Lee, Vince K; Schmithorst, Vince; Panigrahy, Ashok

    2015-01-01

    Preterm born children with spastic diplegia type of cerebral palsy and white matter injury or periventricular leukomalacia (PVL), are known to have motor, visual and cognitive impairments. Most diffusion tensor imaging (DTI) studies performed in this group have demonstrated widespread abnormalities using averaged deterministic tractography and voxel-based DTI measurements. Little is known about structural network correlates of white matter topography and reorganization in preterm cerebral palsy, despite the availability of new therapies and the need for brain imaging biomarkers. Here, we combined novel post-processing methodology of probabilistic tractography data in this preterm cohort to improve spatial and regional delineation of longitudinal cortical association tract abnormalities using an along-tract approach, and compared these data to structural DTI cortical network topology analysis. DTI images were acquired on 16 preterm children with cerebral palsy (mean age 5.6 ± 4) and 75 healthy controls (mean age 5.7 ± 3.4). Despite mean tract analysis, Tract-Based Spatial Statistics (TBSS) and voxel-based morphometry (VBM) demonstrating diffusely reduced fractional anisotropy (FA) reduction in all white matter tracts, the along-tract analysis improved the detection of regional tract vulnerability. The along-tract map-structural network topology correlates revealed two associations: (1) reduced regional posterior-anterior gradient in FA of the longitudinal visual cortical association tracts (inferior fronto-occipital fasciculus, inferior longitudinal fasciculus, optic radiation, posterior thalamic radiation) correlated with reduced posterior-anterior gradient of intra-regional (nodal efficiency) metrics with relative sparing of frontal and temporal regions; and (2) reduced regional FA within frontal-thalamic-striatal white matter pathways (anterior limb/anterior thalamic radiation, superior longitudinal fasciculus and cortical spinal tract) correlated with

  2. Regional vulnerability of longitudinal cortical association connectivity

    Directory of Open Access Journals (Sweden)

    Rafael Ceschin

    2015-01-01

    Full Text Available Preterm born children with spastic diplegia type of cerebral palsy and white matter injury or periventricular leukomalacia (PVL, are known to have motor, visual and cognitive impairments. Most diffusion tensor imaging (DTI studies performed in this group have demonstrated widespread abnormalities using averaged deterministic tractography and voxel-based DTI measurements. Little is known about structural network correlates of white matter topography and reorganization in preterm cerebral palsy, despite the availability of new therapies and the need for brain imaging biomarkers. Here, we combined novel post-processing methodology of probabilistic tractography data in this preterm cohort to improve spatial and regional delineation of longitudinal cortical association tract abnormalities using an along-tract approach, and compared these data to structural DTI cortical network topology analysis. DTI images were acquired on 16 preterm children with cerebral palsy (mean age 5.6 ± 4 and 75 healthy controls (mean age 5.7 ± 3.4. Despite mean tract analysis, Tract-Based Spatial Statistics (TBSS and voxel-based morphometry (VBM demonstrating diffusely reduced fractional anisotropy (FA reduction in all white matter tracts, the along-tract analysis improved the detection of regional tract vulnerability. The along-tract map-structural network topology correlates revealed two associations: (1 reduced regional posterior–anterior gradient in FA of the longitudinal visual cortical association tracts (inferior fronto-occipital fasciculus, inferior longitudinal fasciculus, optic radiation, posterior thalamic radiation correlated with reduced posterior–anterior gradient of intra-regional (nodal efficiency metrics with relative sparing of frontal and temporal regions; and (2 reduced regional FA within frontal–thalamic–striatal white matter pathways (anterior limb/anterior thalamic radiation, superior longitudinal fasciculus and cortical spinal tract

  3. Aberrant supracallosal longitudinal bundle: MR features, pathogenesis and associated clinical phenotype

    International Nuclear Information System (INIS)

    Arrigoni, Filippo; Peruzzo, Denis; Romaniello, Romina; Borgatti, Renato; Righini, Andrea; Parazzini, Cecilia; Colombo, Paola; Bassi, Maria Teresa; Triulzi, Fabio

    2016-01-01

    To describe the MRI and structural features of a peculiar malformation of the corpus callosum (CC) in a group of young patients with intellectual disability. We studied with conventional MRI and DTI a group of subjects showing an aberrant supracallosal bundle, characterized by the presence of a triangle-shaped bulging above the dorsal surface of CC on the midline. Clinical evaluations, CGH-array and instrumental analysis were also collected. Among 85 patients with malformed CC, we identified 15 subjects that showed the supracallosal bundle. The CC was thickened in five cases, long and thinned in three cases, short and thinned in three cases and it had a ''ribbon-like'' appearance in four subjects. Additional brain anomalies were present in eight cases. DTI colour maps and tractography showed that the bundle had an antero-posterior longitudinal orientation and that the tract bifurcated posteriorly, ending in the posterior hippocampi. Patients had different combinations of neurological symptoms, but all showed mild or severe intellectual disability. Combining radiological and genetic data with embryological knowledge of the development of cerebral commissures, we hypothesize that the supracallosal bundle represents a vestigial structure, the dorsal fornix, present during fetal life. Its persistence is associated with intellectual disability. (orig.)

  4. Sobolev gradients and differential equations

    CERN Document Server

    Neuberger, J W

    2010-01-01

    A Sobolev gradient of a real-valued functional on a Hilbert space is a gradient of that functional taken relative to an underlying Sobolev norm. This book shows how descent methods using such gradients allow a unified treatment of a wide variety of problems in differential equations. For discrete versions of partial differential equations, corresponding Sobolev gradients are seen to be vastly more efficient than ordinary gradients. In fact, descent methods with these gradients generally scale linearly with the number of grid points, in sharp contrast with the use of ordinary gradients. Aside from the first edition of this work, this is the only known account of Sobolev gradients in book form. Most of the applications in this book have emerged since the first edition was published some twelve years ago. What remains of the first edition has been extensively revised. There are a number of plots of results from calculations and a sample MatLab code is included for a simple problem. Those working through a fair p...

  5. Comparative Lateralizing Ability of Multimodality MRI in Temporal Lobe Epilepsy

    Directory of Open Access Journals (Sweden)

    Karabekir Ercan

    2016-01-01

    Full Text Available Purpose. The objective is to compare lateralizing ability of three quantitative MR (qMRI modalities to depict changes of hippocampal architecture with clinical entities in temporal lobe epilepsy. Methods. We evaluated 14 patients with clinical and EEG proven diagnosis of unilateral TLE and 15 healthy volunteers. T1-weighted 3D dataset for volumetry, single-voxel 1H MR spectroscopy (MRS, and diffusion tensor imaging (DTI were performed for bilateral hippocampi of all subjects. Results. Individual volumetric measurements provided accurate lateralization in 85% of the patients, spectroscopy in 57%, and DTI in 57%. Higher lateralization ratios were acquired combining volumetry-spectroscopy (85%, spectroscopy-DTI (85%, and volumetry-DTI (100%. Significantly decreased NAA/(Cho+Cr ratios (p=0.002 and increased FA (p=0.001 values were obtained in ipsilateral to epileptogenic hippocampus. Duration of epilepsy and FA values showed a significant negative correlation (p=0.016, r=-0.847. The history of febrile convulsion associated with ipsilateral increased ADC values (p=0.015, r=0.851 and reduced NAA/(Cho+Cr ratios (p=0.047, r=-761. Conclusion. Volumetry, MRS, and DTI studies provide complementary information of hippocampal pathology. For lateralization of epileptogenic focus and preoperative examination, volumetry-DTI combination may be indicative of diagnostic accuracy.

  6. Large Airborne Full Tensor Gradient Data Inversion Based on a Non-Monotone Gradient Method

    Science.gov (United States)

    Sun, Yong; Meng, Zhaohai; Li, Fengting

    2018-03-01

    Following the development of gravity gradiometer instrument technology, the full tensor gravity (FTG) data can be acquired on airborne and marine platforms. Large-scale geophysical data can be obtained using these methods, making such data sets a number of the "big data" category. Therefore, a fast and effective inversion method is developed to solve the large-scale FTG data inversion problem. Many algorithms are available to accelerate the FTG data inversion, such as conjugate gradient method. However, the conventional conjugate gradient method takes a long time to complete data processing. Thus, a fast and effective iterative algorithm is necessary to improve the utilization of FTG data. Generally, inversion processing is formulated by incorporating regularizing constraints, followed by the introduction of a non-monotone gradient-descent method to accelerate the convergence rate of FTG data inversion. Compared with the conventional gradient method, the steepest descent gradient algorithm, and the conjugate gradient algorithm, there are clear advantages of the non-monotone iterative gradient-descent algorithm. Simulated and field FTG data were applied to show the application value of this new fast inversion method.

  7. Magnetoelectric Transverse Gradient Sensor with High Detection Sensitivity and Low Gradient Noise

    OpenAIRE

    Zhang, Mingji; Or, Siu Wing

    2017-01-01

    We report, theoretically and experimentally, the realization of a high detection performance in a novel magnetoelectric (ME) transverse gradient sensor based on the large ME effect and the magnetic field gradient (MFG) technique in a pair of magnetically-biased, electrically-shielded, and mechanically-enclosed ME composites having a transverse orientation and an axial separation. The output voltage of the gradient sensor is directly obtained from the transverse MFG-induced difference in ME vo...

  8. Predictors of Desire to Institutionalization in Dementia Caregivers From a Developing Country.

    Science.gov (United States)

    Sinha, Preeti; Yohannan, Sherin; Thirumoorthy, A; Sivakumar, Palanimuthu Thangaraju

    2017-08-01

    Older adults with dementia have higher rates of institutionalization than those without dementia. Desire to institutionalization (DTI) is an important factor influencing the actual institutionalization but is less well studied. This cross-sectional study examines the DTI with the scale of same name developed by Morycz, in 1985, in a sample of 50 caregivers of patients with dementia in a tertiary clinical care setting in a developing country. Caregiver burden associated with personal strain (by factor analyzed Zarit Burden Interview scale), and stress perceived out of caregiving (by Perceived Stress Scale) predicted higher DTI. Besides, those who were married had lower DTI scores. The factors which didn't affect DTI were total caregiver burden, family and social support, age of patient and caregiver, education of caregiver, severity and duration of dementia, and treatment duration. These results were different from those of developed country-based DTI studies and may indicate sociocultural differences.

  9. Density Gradient Stabilization of Electron Temperature Gradient Driven Turbulence in a Spherical Tokamak

    International Nuclear Information System (INIS)

    Ren, Y.; Kaye, S.M.; Mazzucato, E.; Guttenfelder, W.; Bell, R.E.; Domier, C.W.; LeBlanc, B.P.; Lee, K.C.; Luhmann, N.C. Jr.; Smith, D.R.; Yuh, H.

    2011-01-01

    In this letter we report the first clear experimental observation of density gradient stabilization of electron temperature gradient driven turbulence in a fusion plasma. It is observed that longer wavelength modes, k (perpendicular) ρ s ∼< 10, are most stabilized by density gradient, and the stabilization is accompanied by about a factor of two decrease in the plasma effective thermal diffusivity.

  10. The Origins of UV-optical Color Gradients in Star-forming Galaxies at z ˜ 2: Predominant Dust Gradients but Negligible sSFR Gradients

    Science.gov (United States)

    Liu, F. S.; Jiang, Dongfei; Faber, S. M.; Koo, David C.; Yesuf, Hassen M.; Tacchella, Sandro; Mao, Shude; Wang, Weichen; Guo, Yicheng; Fang, Jerome J.; Barro, Guillermo; Zheng, Xianzhong; Jia, Meng; Tong, Wei; Liu, Lu; Meng, Xianmin

    2017-07-01

    The rest-frame UV-optical (I.e., NUV - B) color is sensitive to both low-level recent star formation (specific star formation rate—sSFR) and dust. In this Letter, we extend our previous work on the origins of NUV - B color gradients in star-forming galaxies (SFGs) at z˜ 1 to those at z˜ 2. We use a sample of 1335 large (semimajor axis radius {R}{SMA}> 0\\buildrel{\\prime\\prime}\\over{.} 18) SFGs with extended UV emission out to 2{R}{SMA} in the mass range {M}* ={10}9{--}{10}11 {M}⊙ at 1.5negative NUV - B color gradients (redder centers), and their color gradients strongly increase with galaxy mass. We also show that the global rest-frame FUV - NUV color is approximately linear with {A}{{V}}, which is derived by modeling the observed integrated FUV to NIR spectral energy distributions of the galaxies. Applying this integrated calibration to our spatially resolved data, we find a negative dust gradient (more dust extinguished in the centers), which steadily becomes steeper with galaxy mass. We further find that the NUV - B color gradients become nearly zero after correcting for dust gradients regardless of galaxy mass. This indicates that the sSFR gradients are negligible and dust reddening is likely the principal cause of negative UV-optical color gradients in these SFGs. Our findings support that the buildup of the stellar mass in SFGs at Cosmic Noon is self-similar inside 2{R}{SMA}.

  11. Rapid Gradient-Echo Imaging

    Science.gov (United States)

    Hargreaves, Brian

    2012-01-01

    Gradient echo sequences are widely used in magnetic resonance imaging (MRI) for numerous applications ranging from angiography to perfusion to functional MRI. Compared with spin-echo techniques, the very short repetition times of gradient-echo methods enable very rapid 2D and 3D imaging, but also lead to complicated “steady states.” Signal and contrast behavior can be described graphically and mathematically, and depends strongly on the type of spoiling: fully balanced (no spoiling), gradient spoiling, or RF-spoiling. These spoiling options trade off between high signal and pure T1 contrast while the flip angle also affects image contrast in all cases, both of which can be demonstrated theoretically and in image examples. As with spin-echo sequences, magnetization preparation can be added to gradient-echo sequences to alter image contrast. Gradient echo sequences are widely used for numerous applications such as 3D perfusion imaging, functional MRI, cardiac imaging and MR angiography. PMID:23097185

  12. Association between portal vein pressure drop gradient after transjugular intrahepatic portosystemic shunt and clinical prognosis

    Directory of Open Access Journals (Sweden)

    XU Zhengguo

    2016-12-01

    Full Text Available ObjectiveTo investigate the association between portal vein pressure drop gradient in patients with cirrhotic portal hypertension treated by transjugular intrahepatic portosystemic shunt (TIPS and clinical prognosis, as well as the ideal range of portal vein pressure drop. MethodsA total of 58 patients who underwent TIPS in Xinqiao Hospital of Third Military Medical University from November 2013 to December 2015 were enrolled. All the patients underwent TIPS and embolization of the gastric coronary vein and the short gastric veins, and the change intervals of portal vein pressure gradient were monitored. The follow-up time ranged from 3 days to 2 years, and the association of portal vein pressure drop gradient with postoperative liver function, splenic function, rebleeding rate, hepatic encephalopathy, and portal hypertensive gastrointestinal diseases was analyzed. The paired t-test was used for comparison of parameters before and after treatment. ResultsThe patients had a significant reduction in liver function on day 3 after surgery. At 2 month after surgery, the levels of TBil was rised and had significant changes[(49.81±27.82μmol/L vs (31.64±17.67 μmol/L,t=5.372,P<0.001]. At 6 months after surgery, red blood cell count and platelet count had no significant changes,but,white blood cell count was reduced[(3.79±1.37)×109/L vs (4.57±2.24×109/L,t=2.835,P=0.006]. There was a 23% reduction in portal vein pressure after surgery (from 30.62±3.56 mmHg before surgery to 21.21±2.90 mmHg after surgery, t=23.318,P<0.001. All the patients had varying degrees of relief of gastrointestinal symptoms associated with portal vein hypertension, such as abdominal distension, poor appetite, and diarrhea. Of all patients, none experienced in-stent restenosis or occlusion and 13 experienced hepatic encephalopathy after surgery, which tended to occur at the time when postoperative portal vein pressure was reduced to 14.7-25.7 mmHg, i

  13. Difficult Tracheal Intubation in Obese Gastric Bypass patients

    DEFF Research Database (Denmark)

    Dohrn, Niclas; Sommer, Thorbjørn; Bisgaard, J.

    2016-01-01

    Endotracheal intubation is commonly perceived to be more difficult in obese patients than in lean patients. Primarily, we investigated the association between difficult tracheal intubation (DTI) and obesity, and secondarily, the association between DTI and validated scoring systems used to assess...... the airways, the association between DTI and quantities of anesthetics used to induce general anesthesia, and the association between DTI and difficulties with venous and arterial cannulation. This is a monocentric prospective observational clinical study of a consecutive series of 539 obese patients...... was 3.5 % and the patients with DTI were more frequently males, had higher CLC, higher American Society of Anesthesiologists physical status classification (ASA), and noticeably, a lower BMI compared to the patients with easy tracheal intubation. After adjustment with multivariable analyses body mass...

  14. Graded/Gradient Porous Biomaterials

    Directory of Open Access Journals (Sweden)

    Xigeng Miao

    2009-12-01

    Full Text Available Biomaterials include bioceramics, biometals, biopolymers and biocomposites and they play important roles in the replacement and regeneration of human tissues. However, dense bioceramics and dense biometals pose the problem of stress shielding due to their high Young’s moduli compared to those of bones. On the other hand, porous biomaterials exhibit the potential of bone ingrowth, which will depend on porous parameters such as pore size, pore interconnectivity, and porosity. Unfortunately, a highly porous biomaterial results in poor mechanical properties. To optimise the mechanical and the biological properties, porous biomaterials with graded/gradient porosity, pores size, and/or composition have been developed. Graded/gradient porous biomaterials have many advantages over graded/gradient dense biomaterials and uniform or homogenous porous biomaterials. The internal pore surfaces of graded/gradient porous biomaterials can be modified with organic, inorganic, or biological coatings and the internal pores themselves can also be filled with biocompatible and biodegradable materials or living cells. However, graded/gradient porous biomaterials are generally more difficult to fabricate than uniform or homogenous porous biomaterials. With the development of cost-effective processing techniques, graded/gradient porous biomaterials can find wide applications in bone defect filling, implant fixation, bone replacement, drug delivery, and tissue engineering.

  15. Clinical feasibility of simultaneous multi-slice imaging with blipped-CAIPI for diffusion-weighted imaging and diffusion-tensor imaging of the brain.

    Science.gov (United States)

    Yokota, Hajime; Sakai, Koji; Tazoe, Jun; Goto, Mariko; Imai, Hiroshi; Teramukai, Satoshi; Yamada, Kei

    2017-12-01

    Background Simultaneous multi-slice (SMS) imaging is starting to be used in clinical situation, although evidence of clinical feasibility is scanty. Purpose To prospectively assess the clinical feasibility of SMS diffusion-weighted imaging (DWI) and diffusion-tensor imaging (DTI) with blipped-controlled aliasing in parallel imaging for brain lesions. Material and Methods The institutional review board approved this study. This study included 156 hyperintense lesions on DWI from 32 patients. A slice acceleration factor of 2 was applied for SMS scans, which allowed shortening of the scan time by 41.3%. The signal-to-noise ratio (SNR) was calculated for brain tissue of a selected slice. The contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated in 36 hyperintense lesions with a diameter of three pixels or more. Visual assessment was performed for all 156 lesions. Tractography of the corticospinal tract of 29 patients was evaluated. The number of tracts and averaged tract length were used for quantitative analysis, and visual assessment was evaluated by grading. Results The SMS scan showed no bias and acceptable 95% limits of agreement compared to conventional scans in SNR, CNR, and ADC on Bland-Altman analyses. Only FA of the lesions was higher in the SMS scan by 9% ( P = 0.016), whereas FA of the surrounding tissues was similar. Quantitative analysis of tractography showed similar values. Visual assessment of DWI hyperintense lesions and tractography also resulted in comparable evaluation. Conclusion SMS imaging was clinically feasible for imaging quality and quantitative values compared with conventional DWI and DTI.

  16. Testing the limits of gradient sensing.

    Directory of Open Access Journals (Sweden)

    Vinal Lakhani

    2017-02-01

    Full Text Available The ability to detect a chemical gradient is fundamental to many cellular processes. In multicellular organisms gradient sensing plays an important role in many physiological processes such as wound healing and development. Unicellular organisms use gradient sensing to move (chemotaxis or grow (chemotropism towards a favorable environment. Some cells are capable of detecting extremely shallow gradients, even in the presence of significant molecular-level noise. For example, yeast have been reported to detect pheromone gradients as shallow as 0.1 nM/μm. Noise reduction mechanisms, such as time-averaging and the internalization of pheromone molecules, have been proposed to explain how yeast cells filter fluctuations and detect shallow gradients. Here, we use a Particle-Based Reaction-Diffusion model of ligand-receptor dynamics to test the effectiveness of these mechanisms and to determine the limits of gradient sensing. In particular, we develop novel simulation methods for establishing chemical gradients that not only allow us to study gradient sensing under steady-state conditions, but also take into account transient effects as the gradient forms. Based on reported measurements of reaction rates, our results indicate neither time-averaging nor receptor endocytosis significantly improves the cell's accuracy in detecting gradients over time scales associated with the initiation of polarized growth. Additionally, our results demonstrate the physical barrier of the cell membrane sharpens chemical gradients across the cell. While our studies are motivated by the mating response of yeast, we believe our results and simulation methods will find applications in many different contexts.

  17. Improved olefinic fat suppression in skeletal muscle DTI using a magnitude-based dixon method.

    Science.gov (United States)

    Burakiewicz, Jedrzej; Hooijmans, Melissa T; Webb, Andrew G; Verschuuren, Jan J G M; Niks, Erik H; Kan, Hermien E

    2018-01-01

    To develop a method of suppressing the multi-resonance fat signal in diffusion-weighted imaging of skeletal muscle. This is particularly important when imaging patients with muscular dystrophies, a group of diseases which cause gradual replacement of muscle tissue by fat. The signal from the olefinic fat peak at 5.3 ppm can significantly confound diffusion-tensor imaging measurements. Dixon olefinic fat suppression (DOFS), a magnitude-based chemical-shift-based method of suppressing the olefinic peak, is proposed. It is verified in vivo by performing diffusion tensor imaging (DTI)-based quantification in the lower leg of seven healthy volunteers, and compared to two previously described fat-suppression techniques in regions with and without fat contamination. In the region without fat contamination, DOFS produces similar results to existing techniques, whereas in muscle contaminated by subcutaneous fat signal moved due to the chemical shift artefact, it consistently showed significantly higher (P = 0.018) mean diffusivity (MD). Because fat presence lowers MD, this suggests improved fat suppression. DOFS offers superior fat suppression and enhances quantitative measurements in the muscle in the presence of fat. DOFS is an alternative to spectral olefinic fat suppression. Magn Reson Med 79:152-159, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Clinically feasible NODDI characterization of glioma using multiband EPI at 7 T

    Directory of Open Access Journals (Sweden)

    Qiuting Wen

    2015-01-01

    Full Text Available Recent technological progress in the multiband echo planer imaging (MB EPI technique enables accelerated MR diffusion weighted imaging (DWI and allows whole brain, multi-b-value diffusion imaging to be acquired within a clinically feasible time. However, its applications at 7 T have been limited due to B1 field inhomogeneity and increased susceptibility artifact. It is an ongoing debate whether DWI at 7 T can be performed properly in patients, and a systematic SNR comparison for multiband spin-echo EPI between 3 T and 7 T has not been methodically studied. The goal of this study was to use MB EPI at 7 T in order to obtain 90-directional multi-shell DWI within a clinically feasible acquisition time for patients with glioma. This study included an SNR comparison between 3 T and 7 T, and the application of B1 mapping and distortion correction procedures for reducing the impact of variations in B0 and B1. The optimized multiband sequence was applied in 20 patients with glioma to generate both DTI and NODDI maps for comparison of values in tumor and normal appearing white matter (NAWM. Our SNR analysis showed that MB EPI at 7 T was comparable to that at 3 T, and the data quality acquired in patients was clinically acceptable. NODDI maps provided unique contrast within the T2 lesion that was not seen in anatomical images or DTI maps. Such contrast may reflect the complexity of tissue compositions associated with disease progression and treatment effects. The ability to consistently obtain high quality diffusion data at 7 T will contribute towards the implementation of a comprehensive brain MRI examination at ultra-high field.

  19. SU-F-J-160: Clinical Evaluation of Targeting Accuracy in Radiosurgery Using Tractography

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R; Han, J; Kim, C; Oh, C [Seoul National University Bundang Hospital, Seongnamsi, GyeonggiDo (Korea, Republic of); Suh, T [The catholic university of Korea, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 males, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve. Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated. Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement. Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment

  20. Quantification of diffusion tensor imaging in normal white matter maturation of early childhood using an automated processing pipeline.

    Science.gov (United States)

    Loh, K B; Ramli, N; Tan, L K; Roziah, M; Rahmat, K; Ariffin, H

    2012-07-01

    The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas. Anatomical MRI and structural DTI were performed cross-sectionally on 26 normal children (newborn to 48 months old), using 1.5-T MRI. The automated processing pipeline was implemented to convert diffusion-weighted images into the NIfTI format. DTI-TK software was used to register the processed images to the ICBM DTI-81 atlas, while AFNI software was used for automated atlas-based volumes of interest (VOIs) and statistical value extraction. DTI exhibited consistent grey-white matter contrast. Triphasic temporal variation of the FA and MD values was noted, with FA increasing and MD decreasing rapidly early in the first 12 months. The second phase lasted 12-24 months during which the rate of FA and MD changes was reduced. After 24 months, the FA and MD values plateaued. DTI is a superior technique to conventional MR imaging in depicting WM maturation. The use of the automated processing pipeline provides a reliable environment for quantitative analysis of high-throughput DTI data. Diffusion tensor imaging outperforms conventional MRI in depicting white matter maturation. • DTI will become an important clinical tool for diagnosing paediatric neurological diseases. • DTI appears especially helpful for developmental abnormalities, tumours and white matter disease. • An automated processing pipeline assists quantitative analysis of high throughput DTI data.

  1. The utility of preoperative diffusion tensor imaging in the surgical management of brainstem cavernous malformations.

    Science.gov (United States)

    Flores, Bruno C; Whittemore, Anthony R; Samson, Duke S; Barnett, Samuel L

    2015-03-01

    Resection of brainstem cavernous malformations (BSCMs) may reduce the risk of stepwise neurological deterioration secondary to hemorrhage, but the morbidity of surgery remains high. Diffusion tensor imaging (DTI) and diffusion tensor tractography (DTT) are neuroimaging techniques that may assist in the complex surgical planning necessary for these lesions. The authors evaluate the utility of preoperative DTI and DTT in the surgical management of BSCMs and their correlation with functional outcome. A retrospective review was conducted to identify patients who underwent resection of a BSCM between 2007 and 2012. All patients had preoperative DTI/DTT studies and a minimum of 6 months of clinical and radiographic follow-up. Five major fiber tracts were evaluated preoperatively using the DTI/DTT protocol: 1) corticospinal tract, 2) medial lemniscus and medial longitudinal fasciculus, 3) inferior cerebellar peduncle, 4) middle cerebellar peduncle, and 5) superior cerebellar peduncle. Scores were applied according to the degree of distortion seen, and the sum of scores was used for analysis. Functional outcomes were measured at hospital admission, discharge, and last clinic visit using modified Rankin Scale (mRS) scores. Eleven patients who underwent resection of a BSCM and preoperative DTI were identified. The mean age at presentation was 49 years, with a male-to-female ratio of 1.75:1. Cranial nerve deficit was the most common presenting symptom (81.8%), followed by cerebellar signs or gait/balance difficulties (54.5%) and hemibody anesthesia (27.2%). The majority of the lesions were located within the pons (54.5%). The mean diameter and estimated volume of lesions were 1.21 cm and 1.93 cm(3), respectively. Using DTI and DTT, 9 patients (82%) were found to have involvement of 2 or more major fiber tracts; the corticospinal tract and medial lemniscus/medial longitudinal fasciculus were the most commonly affected. In 2 patients with BSCMs without pial presentation, DTI

  2. Combined DTI Tractography and Functional MRI Study of the Language Connectome in Healthy Volunteers: Extensive Mapping of White Matter Fascicles and Cortical Activations.

    Directory of Open Access Journals (Sweden)

    François Vassal

    Full Text Available Despite a better understanding of brain language organization into large-scale cortical networks, the underlying white matter (WM connectivity is still not mastered. Here we combined diffusion tensor imaging (DTI fiber tracking (FT and language functional magnetic resonance imaging (fMRI in twenty healthy subjects to gain new insights into the macroscopic structural connectivity of language. Eight putative WM fascicles for language were probed using a deterministic DTI-FT technique: the arcuate fascicle (AF, superior longitudinal fascicle (SLF, uncinate fascicle (UF, temporo-occipital fascicle, inferior fronto-occipital fascicle (IFOF, middle longitudinal fascicle (MdLF, frontal aslant fascicle and operculopremotor fascicle. Specific measurements (i.e. volume, length, fractional anisotropy and precise cortical terminations were derived for each WM fascicle within both hemispheres. Connections between these WM fascicles and fMRI activations were studied to determine which WM fascicles are related to language. WM fascicle volumes showed asymmetries: leftward for the AF, temporoparietal segment of SLF and UF, and rightward for the frontoparietal segment of the SLF. The lateralization of the AF, IFOF and MdLF extended to differences in patterns of anatomical connections, which may relate to specific hemispheric abilities. The leftward asymmetry of the AF was correlated to the leftward asymmetry of fMRI activations, suggesting that the lateralization of the AF is a structural substrate of hemispheric language dominance. We found consistent connections between fMRI activations and terminations of the eight WM fascicles, providing a detailed description of the language connectome. WM fascicle terminations were also observed beyond fMRI-confirmed language areas and reached numerous cortical areas involved in different functional brain networks. These findings suggest that the reported WM fascicles are not exclusively involved in language and might be

  3. Combined DTI Tractography and Functional MRI Study of the Language Connectome in Healthy Volunteers: Extensive Mapping of White Matter Fascicles and Cortical Activations.

    Science.gov (United States)

    Vassal, François; Schneider, Fabien; Boutet, Claire; Jean, Betty; Sontheimer, Anna; Lemaire, Jean-Jacques

    2016-01-01

    Despite a better understanding of brain language organization into large-scale cortical networks, the underlying white matter (WM) connectivity is still not mastered. Here we combined diffusion tensor imaging (DTI) fiber tracking (FT) and language functional magnetic resonance imaging (fMRI) in twenty healthy subjects to gain new insights into the macroscopic structural connectivity of language. Eight putative WM fascicles for language were probed using a deterministic DTI-FT technique: the arcuate fascicle (AF), superior longitudinal fascicle (SLF), uncinate fascicle (UF), temporo-occipital fascicle, inferior fronto-occipital fascicle (IFOF), middle longitudinal fascicle (MdLF), frontal aslant fascicle and operculopremotor fascicle. Specific measurements (i.e. volume, length, fractional anisotropy) and precise cortical terminations were derived for each WM fascicle within both hemispheres. Connections between these WM fascicles and fMRI activations were studied to determine which WM fascicles are related to language. WM fascicle volumes showed asymmetries: leftward for the AF, temporoparietal segment of SLF and UF, and rightward for the frontoparietal segment of the SLF. The lateralization of the AF, IFOF and MdLF extended to differences in patterns of anatomical connections, which may relate to specific hemispheric abilities. The leftward asymmetry of the AF was correlated to the leftward asymmetry of fMRI activations, suggesting that the lateralization of the AF is a structural substrate of hemispheric language dominance. We found consistent connections between fMRI activations and terminations of the eight WM fascicles, providing a detailed description of the language connectome. WM fascicle terminations were also observed beyond fMRI-confirmed language areas and reached numerous cortical areas involved in different functional brain networks. These findings suggest that the reported WM fascicles are not exclusively involved in language and might be related to

  4. Strain gradient effects on cyclic plasticity

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Legarth, Brian Nyvang

    2010-01-01

    Size effects on the cyclic shear response are studied numerically using a recent higher order strain gradient visco-plasticity theory accounting for both dissipative and energetic gradient hardening. Numerical investigations of the response under cyclic pure shear and shear of a finite slab between...... rigid platens have been carried out, using the finite element method. It is shown for elastic–perfectly plastic solids how dissipative gradient effects lead to increased yield strength, whereas energetic gradient contributions lead to increased hardening as well as a Bauschinger effect. For linearly...... hardening materials it is quantified how dissipative and energetic gradient effects promote hardening above that of conventional predictions. Usually, increased hardening is attributed to energetic gradient effects, but here it is found that also dissipative gradient effects lead to additional hardening...

  5. Characteristics of 3D gamma evaluation according to phantom rotation error and dose gradient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Hyun; Kim, Dong Su; Kim, Tae Ho; Kang, Seong Hee; Shin, Dong Seok; Noh, Yu Yoon; Suh, Tae Seok [Dept. of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Seoul (Korea, Republic of); Cho, Min Seok [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2016-12-15

    In intensity modulated radiation therapy (IMRT) quality assurance (QA) using dosimetric phantom, a spatial uncertainty induced from phantom set-up inevitably occurs and gamma index that is used to evaluate IMRT plan quality can be affected differently by a combination of the spatial uncertainty and magnitude of dose gradient. In this study, we investigated the impacts of dose gradient and the phantom set-up error on 3D gamma evaluation. In this study, we investigated the characteristics of gamma evaluation according to dose gradient and phantom rotation axis. As a result, 3D gamma had better performance than 2D gamma. Therefore, it can be useful for IMRT QA analysis at clinical field.

  6. High Gradient Accelerating Structures for Carbon Therapy Linac

    Energy Technology Data Exchange (ETDEWEB)

    Kutsaev, Sergey; Agustsson, R.; Faillace, L.; Goel, A.; Mustapha, B.; Nassiri, A.; Ostroumov, P.; Plastun, A.; Savin, E.

    2016-05-01

    Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

  7. Fetal diffusion tensor quantification of brainstem pathology in Chiari II malformation

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Prayer, Daniela; Weber, Michael; Schoepf, Veronika; Furtner, Julia; Asenbaum, Ulrika; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Department of Clinical Pathology, Vienna (Austria); Seidl, Rainer [Medical University of Vienna, Department of Paediatrics and Adolescent Medicine, Vienna (Austria); Bettelheim, Dieter [Medical University of Vienna, Department of Obstetrics and Gynecology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Center for Anatomy and Cell Biology, Vienna (Austria)

    2016-05-15

    This prenatal MRI study evaluated the potential of diffusion tensor imaging (DTI) metrics to identify changes in the midbrain of fetuses with Chiari II malformations compared to fetuses with mild ventriculomegaly, hydrocephalus and normal CNS development. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated from a region of interest (ROI) in the midbrain of 46 fetuses with normal CNS, 15 with Chiari II malformations, eight with hydrocephalus and 12 with mild ventriculomegaly. Fetuses with different diagnoses were compared group-wise after age-matching. Axial T2W-FSE sequences and single-shot echo planar DTI sequences (16 non-collinear diffusion gradient-encoding directions, b-values of 0 and 700 s/mm{sup 2}, 1.5 Tesla) were evaluated retrospectively. In Chiari II malformations, FA was significantly higher than in age-matched fetuses with a normal CNS (p =.003), while ADC was not significantly different. No differences in DTI metrics between normal controls and fetuses with hydrocephalus or vetriculomegaly were detected. DTI can detect and quantify parenchymal alterations of the fetal midbrain in Chiari II malformations. Therefore, in cases of enlarged fetal ventricles, FA of the fetal midbrain may contribute to the differentiation between Chiari II malformation and other entities. (orig.)

  8. Fetal diffusion tensor quantification of brainstem pathology in Chiari II malformation

    International Nuclear Information System (INIS)

    Woitek, Ramona; Prayer, Daniela; Weber, Michael; Schoepf, Veronika; Furtner, Julia; Asenbaum, Ulrika; Kasprian, Gregor; Amann, Gabriele; Seidl, Rainer; Bettelheim, Dieter; Brugger, Peter C.

    2016-01-01

    This prenatal MRI study evaluated the potential of diffusion tensor imaging (DTI) metrics to identify changes in the midbrain of fetuses with Chiari II malformations compared to fetuses with mild ventriculomegaly, hydrocephalus and normal CNS development. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated from a region of interest (ROI) in the midbrain of 46 fetuses with normal CNS, 15 with Chiari II malformations, eight with hydrocephalus and 12 with mild ventriculomegaly. Fetuses with different diagnoses were compared group-wise after age-matching. Axial T2W-FSE sequences and single-shot echo planar DTI sequences (16 non-collinear diffusion gradient-encoding directions, b-values of 0 and 700 s/mm 2 , 1.5 Tesla) were evaluated retrospectively. In Chiari II malformations, FA was significantly higher than in age-matched fetuses with a normal CNS (p =.003), while ADC was not significantly different. No differences in DTI metrics between normal controls and fetuses with hydrocephalus or vetriculomegaly were detected. DTI can detect and quantify parenchymal alterations of the fetal midbrain in Chiari II malformations. Therefore, in cases of enlarged fetal ventricles, FA of the fetal midbrain may contribute to the differentiation between Chiari II malformation and other entities. (orig.)

  9. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  10. Self-organization of intracellular gradients during mitosis

    Directory of Open Access Journals (Sweden)

    Fuller Brian G

    2010-01-01

    Full Text Available Abstract Gradients are used in a number of biological systems to transmit spatial information over a range of distances. The best studied are morphogen gradients where information is transmitted over many cell lengths. Smaller mitotic gradients reflect the need to organize several distinct events along the length of the mitotic spindle. The intracellular gradients that characterize mitosis are emerging as important regulatory paradigms. Intracellular gradients utilize intrinsic auto-regulatory feedback loops and diffusion to establish stable regions of activity within the mitotic cytosol. We review three recently described intracellular mitotic gradients. The Ran GTP gradient with its elaborate cascade of nuclear transport receptors and cargoes is the best characterized, yet the dynamics underlying the robust gradient of Ran-GTP have received little attention. Gradients of phosphorylation have been observed on Aurora B kinase substrates both before and after anaphase onset. In both instances the phosphorylation gradient appears to result from a soluble gradient of Aurora B kinase activity. Regulatory properties that support gradient formation are highlighted. Intracellular activity gradients that regulate localized mitotic events bare several hallmarks of self-organizing biologic systems that designate spatial information during pattern formation. Intracellular pattern formation represents a new paradigm in mitotic regulation.

  11. Strength gradient enhances fatigue resistance of steels

    Science.gov (United States)

    Ma, Zhiwei; Liu, Jiabin; Wang, Gang; Wang, Hongtao; Wei, Yujie; Gao, Huajian

    2016-02-01

    Steels are heavily used in infrastructure and the transportation industry, and enhancing their fatigue resistance is a major challenge in materials engineering. In this study, by introducing a gradient microstructure into 304 austenitic steel, which is one of the most widely used types of stainless steel, we show that a strength gradient substantially enhances the fatigue life of the material. Pre-notched samples with negative strength gradients in front of the notch’s tip endure many more fatigue cycles than do samples with positive strength gradients during the crack initiation stage, and samples with either type of gradient perform better than do gradient-free samples with the same average yield strength. However, as a crack grows, samples with positive strength gradients exhibit better resistance to fatigue crack propagation than do samples with negative gradients or no gradient. This study demonstrates a simple and promising strategy for using gradient structures to enhance the fatigue resistance of materials and complements related studies of strength and ductility.

  12. Short-term evolution of spinal cord damage in multiple sclerosis: a diffusion tensor MRI study

    International Nuclear Information System (INIS)

    Theaudin, M.; Denier, C.; Adams, D.; Saliou, G.; Ducot, B.; Deiva, K.; Ducreux, D.

    2012-01-01

    The potential of diffusion tensor imaging (DTI) to detect spinal cord abnormalities in patients with multiple sclerosis has already been demonstrated. The objective of this study was to apply DTI techniques to multiple sclerosis patients with a recently diagnosed spinal cord lesion, in order to demonstrate a correlation between variations of DTI parameters and clinical outcome, and to try to identify DTI parameters predictive of outcome. A prospective single-centre study of patients with spinal cord relapse treated by intravenous steroid therapy was made. Patients were assessed clinically and by conventional MRI with DTI sequences at baseline and at 3 months. Sixteen patients were recruited. At 3 months, 12 patients were clinically improved. All but one patient had lower fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values than normal subjects in either inflammatory lesions or normal-appearing spinal cord. Patients who improved at 3 months presented a significant reduction in the radial diffusivity (p = 0.05) in lesions during the follow-up period. They also had a significant reduction in the mean ADC (p = 0.002), axial diffusivity (p = 0.02), radial diffusivity (p = 0.02) and a significant increase in FA values (p = 0.02) in normal-appearing spinal cord. Patients in whom the American Spinal Injury Association sensory score improved at 3 months showed a significantly higher FA (p = 0.009) and lower radial diffusivity (p = 0.04) in inflammatory lesion at baseline compared to patients with no improvement. DTI MRI detects more extensive abnormalities than conventional T2 MRI. A less marked decrease in FA value and more marked decreased in radial diffusivity inside the inflammatory lesion were associated with better outcome. (orig.)

  13. Short-term evolution of spinal cord damage in multiple sclerosis: a diffusion tensor MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Theaudin, M.; Denier, C.; Adams, D. [AP-HP, CHU Bicetre, Service de Neurologie Adultes, Le Kremlin-Bicetre (France); INSERM, UMR788, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); Saliou, G. [AP-HP, CHU Bicetre, Service de Neuroradiologie, Le Kremlin-Bicetre (France); Ducot, B. [INSERM, U1018, CESP Centre for Research in Epidemiology and Population Health, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); Deiva, K. [Service de Neuropediatrie, Le Kremlin-Bicetre (France); Ducreux, D. [INSERM, UMR788, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); AP-HP, CHU Bicetre, Service de Neuroradiologie, Le Kremlin-Bicetre (France)

    2012-10-15

    The potential of diffusion tensor imaging (DTI) to detect spinal cord abnormalities in patients with multiple sclerosis has already been demonstrated. The objective of this study was to apply DTI techniques to multiple sclerosis patients with a recently diagnosed spinal cord lesion, in order to demonstrate a correlation between variations of DTI parameters and clinical outcome, and to try to identify DTI parameters predictive of outcome. A prospective single-centre study of patients with spinal cord relapse treated by intravenous steroid therapy was made. Patients were assessed clinically and by conventional MRI with DTI sequences at baseline and at 3 months. Sixteen patients were recruited. At 3 months, 12 patients were clinically improved. All but one patient had lower fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values than normal subjects in either inflammatory lesions or normal-appearing spinal cord. Patients who improved at 3 months presented a significant reduction in the radial diffusivity (p = 0.05) in lesions during the follow-up period. They also had a significant reduction in the mean ADC (p = 0.002), axial diffusivity (p = 0.02), radial diffusivity (p = 0.02) and a significant increase in FA values (p = 0.02) in normal-appearing spinal cord. Patients in whom the American Spinal Injury Association sensory score improved at 3 months showed a significantly higher FA (p = 0.009) and lower radial diffusivity (p = 0.04) in inflammatory lesion at baseline compared to patients with no improvement. DTI MRI detects more extensive abnormalities than conventional T2 MRI. A less marked decrease in FA value and more marked decreased in radial diffusivity inside the inflammatory lesion were associated with better outcome. (orig.)

  14. SU-E-J-34: Clinical Evaluation of Targeting Accuracy and Tractogrphy Delineation of Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R; Suh, T; Kim, Y; Han, J; Kim, C; Oh, C; Kim, D [Seoul National University Bundang Hospital (Korea, Republic of)

    2014-06-01

    Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 male, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve . Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.

  15. Gradient Boosting Machines, A Tutorial

    Directory of Open Access Journals (Sweden)

    Alexey eNatekin

    2013-12-01

    Full Text Available Gradient boosting machines are a family of powerful machine-learning techniques that have shown considerable success in a wide range of practical applications. They are highly customizable to the particular needs of the application, like being learned with respect to different loss functions. This article gives a tutorial introduction into the methodology of gradient boosting methods. A theoretical information is complemented with many descriptive examples and illustrations which cover all the stages of the gradient boosting model design. Considerations on handling the model complexity are discussed. A set of practical examples of gradient boosting applications are presented and comprehensively analyzed.

  16. The geomagnetic field gradient tensor

    DEFF Research Database (Denmark)

    Kotsiaros, Stavros; Olsen, Nils

    2012-01-01

    We develop the general mathematical basis for space magnetic gradiometry in spherical coordinates. The magnetic gradient tensor is a second rank tensor consisting of 3 × 3 = 9 spatial derivatives. Since the geomagnetic field vector B is always solenoidal (∇ · B = 0) there are only eight independent...... tensor elements. Furthermore, in current free regions the magnetic gradient tensor becomes symmetric, further reducing the number of independent elements to five. In that case B is a Laplacian potential field and the gradient tensor can be expressed in series of spherical harmonics. We present properties...... of the magnetic gradient tensor and provide explicit expressions of its elements in terms of spherical harmonics. Finally we discuss the benefit of using gradient measurements for exploring the Earth’s magnetic field from space, in particular the advantage of the various tensor elements for a better determination...

  17. Block-conjugate-gradient method

    International Nuclear Information System (INIS)

    McCarthy, J.F.

    1989-01-01

    It is shown that by using the block-conjugate-gradient method several, say s, columns of the inverse Kogut-Susskind fermion matrix can be found simultaneously, in less time than it would take to run the standard conjugate-gradient algorithm s times. The method improves in efficiency relative to the standard conjugate-gradient algorithm as the fermion mass is decreased and as the value of the coupling is pushed to its limit before the finite-size effects become important. Thus it is potentially useful for measuring propagators in large lattice-gauge-theory calculations of the particle spectrum

  18. Improved characterisation of stroke phenotype using sequential MR diffusion tensor imaging at 3 tesla

    International Nuclear Information System (INIS)

    Green, H.; Price, C.J.S.; Warburton, E; Pena, A.; Donovan, T.; Carpenter, T.A.; Pickard, J.D.; Gillard, J.H.

    2002-01-01

    Full text: MR diffusion weighted imaging (DWI) enables the identification of early ischemia in acute stroke. Recent advances in DWI allow the identification of anisotropic white matter tracts with diffusion tensor imaging (DTI).We used DTI to study patients with recent stroke in a high field MR system to establish the type of phenotypic abnormalities demonstrated and to determine whether DTI could produce an alternative tool that might be used in studies of clinical outcome and recovery. 25 patients with recent stroke were imaged at 3 Telsa. The extent of abnormality on the conventional and tensor images were compared. Regions of interest were drawn within the area of ischemia and in the contralateral hemisphere. The relative anisotropy index for these areas was calculated and compared. DTI studies were repeated in 11 patients at 1 week and 8 patients at 3 months. DTI was successfully performed in 21 patients. There were 21 men, mean age 58 years (range 25-86 years) imaged at a median of 1 day (range 6 hours to 14 days) from the known time of stroke onset. 19/21 patients demonstrated DWI changes on the b = 1000s/mm2 trace image. DTI imaging was initially normal in 6 patients. The abnormalities consisted of actual disruption of white matter tracts in 13 patients. Ansiotropy indices were reduced to 0.21 in the ischaemic areas compared with 0.34 in normal appearing contralateral white matter (p = 0.016). 2 patients demonstrated distortion of white matter tracts around ischemia induced mass effect. One patient without tract disruption initially had progressed to tract disruption when re-imaged six days from stroke onset. A further patient had distortion of white matter tracts around an infarct and had a good clinical outcome. DTI is able to quantify the extent of white matter tract disruption in acute stroke. The extent or lack of tract destruction may be prognostically important as it provides information that is not available with conventional diffusion or perfusion

  19. Measurement of carotid bifurcation pressure gradients using the Bernoulli principle.

    Science.gov (United States)

    Illig, K A; Ouriel, K; DeWeese, J A; Holen, J; Green, R M

    1996-04-01

    Current randomized prospective studies suggest that the degree of carotid stenosis is a critical element in deciding whether surgical or medical treatment is appropriate. Of potential interest is the actual pressure drop caused by the blockage, but no direct non-invasive means of quantifying the hemodynamic consequences of carotid artery stenoses currently exists. The present prospective study examined whether preoperative pulsed-Doppler duplex ultrasonographic velocity (v) measurements could be used to predict pressure gradients (delta P) caused by carotid artery stenoses, and whether such measurements could be used to predict angiographic percent diameter reduction. Preoperative Doppler velocity and intraoperative direct pressure measurements were obtained, and per cent diameter angiographic stenosis measured in 76 consecutive patients who underwent 77 elective carotid endarterectomies. Using the Bernoulli principle (delta P = 4v(2), pressure gradients across the stenoses were calculated. The predicted delta P, as well as absolute velocities and internal carotid artery/common carotid velocity ratios were compared with the actual delta P measured intraoperatively and with preoperative angiography and oculopneumoplethysmography (OPG) results. An end-diastolic velocity of > or = 1 m/s and an end-diastolic internal carotid artery/common carotid artery velocity ratio of > or = 10 predicted a 50% diameter angiographic stenosis with 100% specificity. Although statistical significance was reached, preoperative pressure gradients derived from the Bernoulli equation could not predict actual individual intraoperative pressure gradients with enough accuracy to allow decision making on an individual basis. Velocity measurements were as specific and more sensitive than OPG results. Delta P as predicted by the Bernoulli equation is not sufficiently accurate at the carotid bifurcation to be useful for clinical decision making on an individual basis. However, end

  20. Altered microstructural connectivity of the superior and middle cerebellar peduncles are related to motor dysfunction in children with diffuse periventricular leucomalacia born preterm: A DTI tractography study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shanshan, E-mail: jelly_66@126.com; Fan, Guo Guang, E-mail: cjr.fanguoguang@vip.163.com; Xu, Ke, E-mail: cjr.xuke@vip.163.com; Wang, Ci, E-mail: xiangxuehai19850224@yahoo.cn

    2014-06-15

    Purpose: To investigate the microstructural integrity of superior cerebellar peduncles (SCP) and middle cerebellar peduncles (MCP) by using DTI tractography method, and further to detect whether the microstructural integrity of these major cerebellar pathways is related to motor function in children with diffuse periventricular leucomalacia (PVL) born preterm. Materials and methods: 46 children with diffuse PVL (30 males and 16 females; age range 3–48 months; mean age 22.4 ± 6.7 months; mean gestational age 30.5 ± 2.2 weeks) and 40 healthy controls (27 males and 13 females; age range 3.5–48 months; mean age 22.1 ± 5.8 months) were enrolled in this study. DTI outcome measurements, fractional anisotropy (FA), for the SCP, MCP and cortical spinal tract (CST) were calculated. The gross motor function classification system (GMFCS) was used for assessing motor functions. Results: Compared to the controls, patients with diffuse PVL had a significantly lower FA in bilateral SCP, MCP and CST. There was a significant negative correlation between GMFCS levels and FA in bilateral SCP, MCP and CST in the patients group. In addition, significant inverse correlation of FA value was found between not only the contralateral but also the ipsilateral CST and SCP/MCP. Conclusions: These findings suggest that the injury of SCP and MCP may contribute to the motor dysfunction of diffuse PVL. Moreover, the correlations we found between supratentorial and subtentorial injured white matter extend our knowledge about the cerebro-cerebellar white matter interaction in children with diffuse PVL.

  1. Altered microstructural connectivity of the superior and middle cerebellar peduncles are related to motor dysfunction in children with diffuse periventricular leucomalacia born preterm: A DTI tractography study

    International Nuclear Information System (INIS)

    Wang, Shanshan; Fan, Guo Guang; Xu, Ke; Wang, Ci

    2014-01-01

    Purpose: To investigate the microstructural integrity of superior cerebellar peduncles (SCP) and middle cerebellar peduncles (MCP) by using DTI tractography method, and further to detect whether the microstructural integrity of these major cerebellar pathways is related to motor function in children with diffuse periventricular leucomalacia (PVL) born preterm. Materials and methods: 46 children with diffuse PVL (30 males and 16 females; age range 3–48 months; mean age 22.4 ± 6.7 months; mean gestational age 30.5 ± 2.2 weeks) and 40 healthy controls (27 males and 13 females; age range 3.5–48 months; mean age 22.1 ± 5.8 months) were enrolled in this study. DTI outcome measurements, fractional anisotropy (FA), for the SCP, MCP and cortical spinal tract (CST) were calculated. The gross motor function classification system (GMFCS) was used for assessing motor functions. Results: Compared to the controls, patients with diffuse PVL had a significantly lower FA in bilateral SCP, MCP and CST. There was a significant negative correlation between GMFCS levels and FA in bilateral SCP, MCP and CST in the patients group. In addition, significant inverse correlation of FA value was found between not only the contralateral but also the ipsilateral CST and SCP/MCP. Conclusions: These findings suggest that the injury of SCP and MCP may contribute to the motor dysfunction of diffuse PVL. Moreover, the correlations we found between supratentorial and subtentorial injured white matter extend our knowledge about the cerebro-cerebellar white matter interaction in children with diffuse PVL

  2. Fast diffusion tensor magnetic resonance imaging of the mouse brain at ultrahigh-field: aiming at cohort studies.

    Directory of Open Access Journals (Sweden)

    Hans-Peter Müller

    Full Text Available INTRODUCTION: In-vivo high resolution diffusion tensor imaging (DTI of the mouse brain is often limited by the low signal to noise ratio (SNR resulting from the required small voxel sizes. Recently, cryogenically cooled resonators (CCR have demonstrated significant increase of the effective SNR. It is the objective of this study to enable fast DTI of the mouse brain. In this context, CCRs appear attractive for SNR improvement. METHODS: Three mice underwent a DTI examination at 156²×250 µm³ spatial resolution with a CCR at ultrahigh field (11.7T. Diffusion images were acquired along 30 gradient directions plus 5 references without diffusion encoding, resulting in a total acquisition time of 35 minutes. For comparison, mice additionally underwent a standardized 110 minutes acquisition protocol published earlier. Fractional anisotropy (FA and fiber tracking (FT results including quantitative tractwise fractional anisotropy statistics (TFAS were qualitatively and quantitatively compared. RESULTS: Qualitative and quantitative assessment of the calculated fractional anisotropy maps and fibre tracking results showed coinciding outcome comparing 35 minute scans to the standardized 110 minute scan. Coefficients of variation for ROI-based FA-comparison as well as for TFAS revealed comparable results for the different scanning protocols. CONCLUSION: Mouse DTI at 11.7 T was performed with an acquisition time of approximately 30 minutes, which is considered feasible for cohort studies. The rapid acquisition protocol reveals reliable and reproducible FA-values and FT reconstructions, thus allowing an experimental setup for in-vivo large scale whole brain murine DTI cohort studies.

  3. Gradient Alloy for Optical Packaging

    Data.gov (United States)

    National Aeronautics and Space Administration — Advances in additive manufacturing, such as Laser Engineered Net Shaping (LENS), enables the fabrication of compositionally gradient microstructures, i.e. gradient...

  4. Three-dimensional display of peripheral nerves in the wrist region based on MR diffusion tensor imaging and maximum intensity projection post-processing

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Wen Quan, E-mail: dingwenquan1982@163.com [Department of Hand Surgery, Hand Surgery Research Center, Affiliated Hospital of Nantong University, Nantong, Jiangsu (China); Zhou, Xue Jun, E-mail: zxj0925101@sina.com [Department of Radiology, Affiliated Hospital of Nantong University, Nantong, Jiangsu (China); Tang, Jin Bo, E-mail: jinbotang@yahoo.com [Department of Hand Surgery, Hand Surgery Research Center, Affiliated Hospital of Nantong University, Nantong, Jiangsu (China); Gu, Jian Hui, E-mail: gujianhuint@163.com [Department of Hand Surgery, Hand Surgery Research Center, Affiliated Hospital of Nantong University, Nantong, Jiangsu (China); Jin, Dong Sheng, E-mail: jindongshengnj@aliyun.com [Department of Radiology, Jiangsu Province Official Hospital, Nanjing, Jiangsu (China)

    2015-06-15

    Highlights: • 3D displays of peripheral nerves can be achieved by 2 MIP post-processing methods. • The median nerves’ FA and ADC values can be accurately measured by using DTI6 data. • Adopting 6-direction DTI scan and MIP can evaluate peripheral nerves efficiently. - Abstract: Objectives: To achieve 3-dimensional (3D) display of peripheral nerves in the wrist region by using maximum intensity projection (MIP) post-processing methods to reconstruct raw images acquired by a diffusion tensor imaging (DTI) scan, and to explore its clinical applications. Methods: We performed DTI scans in 6 (DTI6) and 25 (DTI25) diffusion directions on 20 wrists of 10 healthy young volunteers, 6 wrists of 5 patients with carpal tunnel syndrome, 6 wrists of 6 patients with nerve lacerations, and one patient with neurofibroma. The MIP post-processing methods employed 2 types of DTI raw images: (1) single-direction and (2) T{sub 2}-weighted trace. The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the median and ulnar nerves were measured at multiple testing sites. Two radiologists used custom evaluation scales to assess the 3D nerve imaging quality independently. Results: In both DTI6 and DTI25, nerves in the wrist region could be displayed clearly by the 2 MIP post-processing methods. The FA and ADC values were not significantly different between DTI6 and DTI25, except for the FA values of the ulnar nerves at the level of pisiform bone (p = 0.03). As to the imaging quality of each MIP post-processing method, there were no significant differences between DTI6 and DTI25 (p > 0.05). The imaging quality of single-direction MIP post-processing was better than that from T{sub 2}-weighted traces (p < 0.05) because of the higher nerve signal intensity. Conclusions: Three-dimensional displays of peripheral nerves in the wrist region can be achieved by MIP post-processing for single-direction images and T{sub 2}-weighted trace images for both DTI6 and DTI25

  5. Validation of diffusion tensor MRI measurements of cardiac microstructure with structure tensor synchrotron radiation imaging.

    Science.gov (United States)

    Teh, Irvin; McClymont, Darryl; Zdora, Marie-Christine; Whittington, Hannah J; Davidoiu, Valentina; Lee, Jack; Lygate, Craig A; Rau, Christoph; Zanette, Irene; Schneider, Jürgen E

    2017-03-10

    Diffusion tensor imaging (DTI) is widely used to assess tissue microstructure non-invasively. Cardiac DTI enables inference of cell and sheetlet orientations, which are altered under pathological conditions. However, DTI is affected by many factors, therefore robust validation is critical. Existing histological validation is intrinsically flawed, since it requires further tissue processing leading to sample distortion, is routinely limited in field-of-view and requires reconstruction of three-dimensional volumes from two-dimensional images. In contrast, synchrotron radiation imaging (SRI) data enables imaging of the heart in 3D without further preparation following DTI. The objective of the study was to validate DTI measurements based on structure tensor analysis of SRI data. One isolated, fixed rat heart was imaged ex vivo with DTI and X-ray phase contrast SRI, and reconstructed at 100 μm and 3.6 μm isotropic resolution respectively. Structure tensors were determined from the SRI data and registered to the DTI data. Excellent agreement in helix angles (HA) and transverse angles (TA) was observed between the DTI and structure tensor synchrotron radiation imaging (STSRI) data, where HA DTI-STSRI  = -1.4° ± 23.2° and TA DTI-STSRI  = -1.4° ± 35.0° (mean ± 1.96 standard deviation across all voxels in the left ventricle). STSRI confirmed that the primary eigenvector of the diffusion tensor corresponds with the cardiomyocyte long-axis across the whole myocardium. We have used STSRI as a novel and high-resolution gold standard for the validation of DTI, allowing like-with-like comparison of three-dimensional tissue structures in the same intact heart free of distortion. This represents a critical step forward in independently verifying the structural basis and informing the interpretation of cardiac DTI data, thereby supporting the further development and adoption of DTI in structure-based electro-mechanical modelling and routine clinical

  6. Coding gaze tracking data with chromatic gradients for VR Exposure Therapy

    DEFF Research Database (Denmark)

    Herbelin, Bruno; Grillon, Helena; De Heras Ciechomski, Pablo

    2007-01-01

    This article presents a simple and intuitive way to represent the eye-tracking data gathered during immersive virtual reality exposure therapy sessions. Eye-tracking technology is used to observe gaze movements during vir- tual reality sessions and the gaze-map chromatic gradient coding allows to...... is fully compatible with different VR exposure systems and provides clinically meaningful data....

  7. Tubing-Electrospinning: A One-Step Process for Fabricating Fibrous Matrices with Spatial, Chemical, and Mechanical Gradients.

    Science.gov (United States)

    Kim, Jung-Suk; Im, Byung Gee; Jin, Gyuhyung; Jang, Jae-Hyung

    2016-08-31

    Guiding newly generated tissues in a gradient pattern, thereby precisely mimicking inherent tissue morphology and subsequently arranging the intimate networks between adjacent tissues, is essential to raise the technical levels of tissue engineering and facilitate its transition into the clinic. In this study, a straightforward electrospinning method (the tubing-electrospinning technique) was developed to create fibrous matrices readily with diverse gradient patterns and to induce patterned cellular responses. Gradient fibrous matrices can be produced simply by installing a series of polymer-containing lengths of tubing into an electrospinning circuit and sequentially processing polymers without a time lag. The loading of polymer samples with different characteristics, including concentration, wettability, and mechanical properties, into the tubing system enabled unique features in fibrous matrices, such as longitudinal gradients in fiber density, surface properties, and mechanical stiffness. The resulting fibrous gradients were shown to arrange cellular migration and residence in a gradient manner, thereby offering efficient cues to mediate patterned tissue formation. The one-step process using tubing-electrospinning apparatus can be used without significant modifications regardless of the type of fibrous gradient. Hence, the tubing-electrospinning system can serve as a platform that can be readily used by a wide-range of users to induce patterned tissue formation in a gradient manner, which will ultimately improve the functionality of tissue engineering scaffolds.

  8. COMPARISON OF GKS CALCULATED CRITICAL ION TEMPERATURE GRADIENTS AND ITG GROWTH RATES TO DIII-D MEASURED GRADIENTS AND DIFFUSIVITIES

    International Nuclear Information System (INIS)

    BAKER, DR; STAEBLER, GM; PETTY, CC; GREENFIELD, CM; LUCE, TC

    2003-01-01

    OAK-B135 The gyrokinetic equations predict that various drift type waves or modes can be unstable in a tokamak. For some of these modes, such as the ion temperature gradient (ITG) mode and the electron temperature gradient mode, there exists a critical gradient, above which the mode is unstable. Since the existence of unstable modes can cause increased transport, plasmas which are centrally heated tend to increase in temperature gradient until the modes become unstable. Under some conditions the increased transport can fix the gradient at the critical value. here they present a comparison between the measured ion temperature gradients and the critical gradient as calculated by a gyrokinetic linear stability (GKS) code. They also present the maximum linear growth rate as calculated by this code for comparison to experimentally derived transport coefficients. The results show that for low confinement mode (L-mode) discharges, the measured ion temperature gradient is significantly greater than the GKS calculated critical gradient over a large region of the plasma. This is the same region of the plasma where the ion thermal diffusivity is large. For high confinement mode (H-mode) discharges the ion temperature gradient is closer to the critical gradient, but often still greater than the critical gradient over some region. For the best H-mode discharges, the ion temperature is less than or equal to the critical gradient over the whole plasma. In general they find that the position in the plasma where the ion thermal diffusivity starts to increase rapidly is where the maximum linear growth rate is greater than the E x B shearing rate

  9. fMRI. Basics and clinical applications. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Stephan [Medizinisch Radiologisces Institut (MRI), Zuerich (Switzerland); Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Neuroradiologie; Jansen, Olav (eds.) [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Neuroradiologie

    2013-11-01

    State of the art overview of fMRI. Covers technical issues, methods of statistical analysis, and the full range of clinical applications. Revised and expanded edition including discussion of novel aspects of analysis and further important applications. Includes comparisons with other brain mapping techniques and discussion of potential combined uses. Since functional MRI (fMRI) and the basic method of BOLD imaging were introduced in 1993 by Seiji Ogawa, fMRI has evolved into an invaluable clinical tool for routine brain imaging, and there have been substantial improvements in both the imaging technique itself and the associated statistical analysis. This book provides a state of the art overview of fMRI and its use in clinical practice. Experts in the field share their knowledge and explain how to overcome diverse potential technical barriers and problems. Starting from the very basics on the origin of the BOLD signal, the book covers technical issues, anatomical landmarks, the full range of clinical applications, methods of statistical analysis, and special issues in various clinical fields. Comparisons are made with other brain mapping techniques, such as DTI, PET, TMS, EEG, and MEG, and their combined use with fMRI is also discussed. Since the first edition, original chapters have been updated and new chapters added, covering both novel aspects of analysis and further important clinical applications.

  10. Strain gradient effects in surface roughening

    DEFF Research Database (Denmark)

    Borg, Ulrik; Fleck, N.A.

    2007-01-01

    evidence for strain gradient effects. Numerical analyses of a bicrystal undergoing in-plane tensile deformation are also studied using a strain gradient crystal plasticity theory and also by using a strain gradient plasticity theory for an isotropic solid. Both theories include an internal material length...

  11. Patterns of macromycete community assemblage along an elevation gradient: options for fungal gradient and metacommunity analyse

    Science.gov (United States)

    Marko Gómez-Hernández; Guadalupe Williams-Linera; Roger Guevara; D. Jean Lodge

    2012-01-01

    Gradient analysis is rarely used in studies of fungal communities. Data on macromycetes from eight sites along an elevation gradient in central Veracruz, Mexico, were used to demonstrate methods for gradient analysis that can be applied to studies of communities of fungi. Selected sites from 100 to 3,500 m altitude represent tropical dry forest, tropical montane cloud...

  12. A new study on diffusion tensor imaging of the whole visual pathway fiber bundle and clinical application

    Institute of Scientific and Technical Information of China (English)

    TAO Xiao-feng; WANG Zhong-qiu; GONG Wan-qing; JIANG Qing-jun; SHI Zeng-ru

    2009-01-01

    Background With conventional imaging methods only the morphous of the visual nerve fiber bundles can be demonstrated, while the earlier period functional changes can not be demonstrated. We hypothesized that diffusion tensor imaging (DTI) would demonstrated the whole optic never fiber bundle and visual pathway and the earlier period functional changes. The purpose of the present study was to evaluate the application of DTI technique in the demonstration of the whole optic never fiber bundle and visual pathway, and the influence of orbital tumors on them. Methods GE 1.5T signa HD MR System, and the software package DTV2 were adopted. The total 45 subjects were enrolled, including 15 volunteers and 30 patients. All patients had ocular proptosis from minor to major. Seven patients had visual acuity decrescence. Results The nerve fiber bundles, e.g. optic chiasma, optic tract and optic radiation in posterior visual pathway were well demonstrated in all cases. Wherein, the intact whole visual pathway fiber bundles were clearly revealed in 10 volunteers and 17 patients, and optic nerve was not wholly revealed in the rest of the subjects. Shift of optic nerve caused by compression and partial deformation were seen in 7 patients with orbital tumor. In 6 of 7 patients, DTI displayed significant abscise and deformation of visual nerve. Chi-square test indicated significant correlation between visual acuity decrescence and DTI visual nerve non-display. Conclusions Visual nerve fiber bundles and the whole visual pathway were visualized in most of patients with DTI. It might be an effective method of providing imaging evidence for visual nerve fiber earlier period functional changes, and laid a foundation for the study in other cranial nerves.

  13. A PD-SOI based DTI-LOCOS combined cross isolation technique for minimizing TID radiation induced leakage in high density memory

    International Nuclear Information System (INIS)

    Qiao Fengying; Pan Liyang; Wu Dong; Liu Lifang; Xu Jun

    2014-01-01

    In order to minimize leakage current increase under total ionizing dose (TID) radiation in high density memory circuits, a new isolation technique, combining deep trench isolation (DTI) between the wells, local oxidation of silicon (LOCOS) isolation between the devices within the well, and a P-diffused area in order to limit leakage at the isolation edge is implemented in partly-depleted silicon-on-insulator (PD-SOI) technology. This radiation hardening technique can minimize the layout area by more than 60%, and allows flexible placement of the body contact. Radiation hardened transistors and 256 Kb flash memory chips are designed and fabricated in a 0.6 μm PD-SOI process. Experiments show that no obvious increase in leakage current is observed for single transistors under 1 Mrad(Si) radiation, and that the 256 Kb memory chip still functions well after a TID of 100 krad(Si), with only 50% increase of the active power consumption in read mode. (semiconductor devices)

  14. The need for clinical quantification of combined PET/MRI data in pediatric epilepsy

    International Nuclear Information System (INIS)

    Muzik, Otto; Pai, Darshan; Juhasz, Csaba; Hua, Jing

    2013-01-01

    In the past, multimodality integrative analysis of image data has been used to obtain a better understanding of underlying mechanisms of seizure generation and propagation in children with extratemporal lobe epilepsy. However, despite important advances in the combined analysis of PET, MRI, DTI and EEG data, successful surgical outcome is only achieved in about 2/3 of patients undergoing resective surgery. The advent of simultaneous PET/MR data acquisition promises an important advance in neuroimaging through clinical quantification, which will finally translate the strength of PET (which is the ability to absolutely quantify physiological parameters such as metabolic rates and receptor densities) into clinical work. Taking advantage of recently developed integrated PET/MR devices, absolute physiological values will be available in clinical routine, replacing currently used visual assessment of relative tissue tracer uptake. This will allow assessment of global increases/decreases of brain function during critical phases of development and is likely to have a significant impact on patient management in pediatric epilepsy

  15. The need for clinical quantification of combined PET/MRI data in pediatric epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Muzik, Otto, E-mail: otto@pet.wayne.edu [Department of Pediatrics, Wayne State University School of Medicine, Detroit, MI (United States); Department of Radiology, Wayne State University School of Medicine, Detroit, MI (United States); Pai, Darshan [Department of Computer Science, Wayne State University School of Medicine, Detroit, MI (United States); Juhasz, Csaba [Department of Pediatrics, Wayne State University School of Medicine, Detroit, MI (United States); Hua, Jing [Department of Computer Science, Wayne State University School of Medicine, Detroit, MI (United States)

    2013-02-21

    In the past, multimodality integrative analysis of image data has been used to obtain a better understanding of underlying mechanisms of seizure generation and propagation in children with extratemporal lobe epilepsy. However, despite important advances in the combined analysis of PET, MRI, DTI and EEG data, successful surgical outcome is only achieved in about 2/3 of patients undergoing resective surgery. The advent of simultaneous PET/MR data acquisition promises an important advance in neuroimaging through clinical quantification, which will finally translate the strength of PET (which is the ability to absolutely quantify physiological parameters such as metabolic rates and receptor densities) into clinical work. Taking advantage of recently developed integrated PET/MR devices, absolute physiological values will be available in clinical routine, replacing currently used visual assessment of relative tissue tracer uptake. This will allow assessment of global increases/decreases of brain function during critical phases of development and is likely to have a significant impact on patient management in pediatric epilepsy.

  16. Evaluation of deep gray matter volume, cortical thickness and white matter integrity in patients with typical absence epilepsy: a study using voxelwise-based techniques

    Energy Technology Data Exchange (ETDEWEB)

    Correa, D.G.; Ventura, N.; Tukamoto, G.; Gasparetto, E.L. [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro (Brazil); Zimmermann, N. [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Pontifical Catholic University of Rio Grande do Sul, Department of Psychology, Porto Alegre (Brazil); Doring, T.M. [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro (Brazil); Leme, J.; Pereira, M. [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Andrea, I. d' ; Rego, C.; Alves-Leon, S.V. [Federal University of Rio de Janeiro, Department of Neurology, Epilepsy Center, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro (Brazil)

    2017-03-15

    The objective of this study was to evaluate the cortical thickness and the volume of deep gray matter structures, measured from 3D T1-weighted gradient echo imaging, and white matter integrity, by diffusion tensor imaging (DTI) in patients with typical absence epilepsy (AE). Patients (n = 19) with typical childhood AE and juvenile AE, currently taking antiepileptic medication, were compared with control subjects (n = 19), matched for gender and age. 3D T1 magnetization-prepared rapid gradient echo-weighted imaging and DTI along 30 noncolinear directions were performed using a 1.5-T MR scanner. FreeSurfer was used to perform cortical volumetric reconstruction and segmentation of deep gray matter structures. For tract-based spatial statistics analysis of DTI, a white matter skeleton was created, along with a permutation-based inference with 5000 permutations. A threshold of p < 0.05 was used to identify abnormalities in fractional anisotropy (FA). The mean, radial, and axial diffusivities were also projected onto the mean FA skeleton. Patients with AE presented decreased FA and increased mean diffusivity and radial diffusivity values in the genu and the body of the corpus callosum and right anterior corona radiata, as well as decreased axial diffusivity in the left posterior thalamic radiation, inferior cerebellar peduncle, right cerebral peduncle, and right corticospinal tract. However, there were no significant differences in cortical thickness or deep gray matter structure volumes between patients with AE and controls. Abnormalities found in white matter integrity may help to better understand the pathophysiology of AE and optimize diagnosis and treatment strategies. (orig.)

  17. Evaluation of deep gray matter volume, cortical thickness and white matter integrity in patients with typical absence epilepsy: a study using voxelwise-based techniques

    International Nuclear Information System (INIS)

    Correa, D.G.; Ventura, N.; Tukamoto, G.; Gasparetto, E.L.; Zimmermann, N.; Doring, T.M.; Leme, J.; Pereira, M.; Andrea, I. d'; Rego, C.; Alves-Leon, S.V.

    2017-01-01

    The objective of this study was to evaluate the cortical thickness and the volume of deep gray matter structures, measured from 3D T1-weighted gradient echo imaging, and white matter integrity, by diffusion tensor imaging (DTI) in patients with typical absence epilepsy (AE). Patients (n = 19) with typical childhood AE and juvenile AE, currently taking antiepileptic medication, were compared with control subjects (n = 19), matched for gender and age. 3D T1 magnetization-prepared rapid gradient echo-weighted imaging and DTI along 30 noncolinear directions were performed using a 1.5-T MR scanner. FreeSurfer was used to perform cortical volumetric reconstruction and segmentation of deep gray matter structures. For tract-based spatial statistics analysis of DTI, a white matter skeleton was created, along with a permutation-based inference with 5000 permutations. A threshold of p < 0.05 was used to identify abnormalities in fractional anisotropy (FA). The mean, radial, and axial diffusivities were also projected onto the mean FA skeleton. Patients with AE presented decreased FA and increased mean diffusivity and radial diffusivity values in the genu and the body of the corpus callosum and right anterior corona radiata, as well as decreased axial diffusivity in the left posterior thalamic radiation, inferior cerebellar peduncle, right cerebral peduncle, and right corticospinal tract. However, there were no significant differences in cortical thickness or deep gray matter structure volumes between patients with AE and controls. Abnormalities found in white matter integrity may help to better understand the pathophysiology of AE and optimize diagnosis and treatment strategies. (orig.)

  18. Velocity ratio predicts outcomes in patients with low gradient severe aortic stenosis and preserved EF

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Hochholzer, Willibald; Kaufmann, Beat A

    2014-01-01

    OBJECTIVE: To evaluate the usefulness of velocity ratio (VR) in patients with low gradient severe aortic stenosis (LGSAS) and preserved EF. BACKGROUND: LGSAS despite preserved EF represents a clinically challenging entity. Reliance on mean pressure gradient (MPG) may underestimate stenosis severity...... for severe stenosis. We hypothesised that VR may have conceptual advantages over MPG and AVA, predict clinical outcomes and thereby be useful in the management of patients with LGSAS. METHODS: Patients from the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study with an AVA...≤40 mm Hg and EF≥55% and asymptomatic at baseline were stratified according to VR with a cut-off value of 0.25. Outcomes were evaluated according to aortic valve-related events and cardiovascular death. RESULTS: Of 435 patients with LGSAS, 197 (45%) had VRVR≥0...

  19. Direct diffusion tensor estimation using a model-based method with spatial and parametric constraints.

    Science.gov (United States)

    Zhu, Yanjie; Peng, Xi; Wu, Yin; Wu, Ed X; Ying, Leslie; Liu, Xin; Zheng, Hairong; Liang, Dong

    2017-02-01

    To develop a new model-based method with spatial and parametric constraints (MB-SPC) aimed at accelerating diffusion tensor imaging (DTI) by directly estimating the diffusion tensor from highly undersampled k-space data. The MB-SPC method effectively incorporates the prior information on the joint sparsity of different diffusion-weighted images using an L1-L2 norm and the smoothness of the diffusion tensor using a total variation seminorm. The undersampled k-space datasets were obtained from fully sampled DTI datasets of a simulated phantom and an ex-vivo experimental rat heart with acceleration factors ranging from 2 to 4. The diffusion tensor was directly reconstructed by solving a minimization problem with a nonlinear conjugate gradient descent algorithm. The reconstruction performance was quantitatively assessed using the normalized root mean square error (nRMSE) of the DTI indices. The MB-SPC method achieves acceptable DTI measures at an acceleration factor up to 4. Experimental results demonstrate that the proposed method can estimate the diffusion tensor more accurately than most existing methods operating at higher net acceleration factors. The proposed method can significantly reduce artifact, particularly at higher acceleration factors or lower SNRs. This method can easily be adapted to MR relaxometry parameter mapping and is thus useful in the characterization of biological tissue such as nerves, muscle, and heart tissue. © 2016 American Association of Physicists in Medicine.

  20. Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques

    Directory of Open Access Journals (Sweden)

    S Timothy Chelliah

    2011-01-01

    Full Text Available Aims: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard. Materials and Methods: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge during transjugular liver biopsy under fluoroscopic guidance. Statistical Analysis: Spearman′s rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. Results: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001. Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. Conclusions: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

  1. The clinical utility of MR diffusion tensor imaging and spatially normalized PET to evaluate traumatic brain injury patients with memory and cognitive impairments

    International Nuclear Information System (INIS)

    Okumura, Ayumi; Yasokawa, Yuuto; Nakayama, Noriyuki; Miwa, Kazuhiro; Shinoda, Jun; Iwama, Toru

    2005-01-01

    We detected and compared abnormal brain areas using both MR diffusion tensor imaging (DTI) and easy Z score imaging system (eZIS) of fluorodeoxyglucose (FDG)-PET for traumatic brain injury patients with memory and cognitive impairments. Twenty normal subjects and eighteen diffuse axonal injury patients with memory and cognitive impairments were studied with DTI and eZIS of 18 F-FDG-PET. DTI contained fractional anisotorophy (FA) analysis and the tractography for the corpus callosum. After PET imaging was performed, statistical analysis using eZIS was undergone with followed processing steps, including smoothing, normalization and z transformation with respect to normal database. Z score map was superimposed on 3D MRI brain. Group analysis was performed using statistical parametric mapping (SPM). In diffuse axonal injury patients, the decline of FA was observed around the corpus callosum in comparison with normal subjects and the reduction of glucose metabolism was shown in the cingulated association. These results suggest that the reduction of metabolism within the cingulated cortex indicated deprived neuronal activation caused by the impaired neuronal connectivity that was revealed with DTI. Furthermore, the metabolic abnormalities within the cingulated cortex may be responsible for memory and cognitive impairments. DTI and spatially normalized PET have a role in neuroimaging interpretation for patients with memory and cognition impairments be cause its 3D better visualization allows objective and systematic investigation. (author)

  2. TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

    Energy Technology Data Exchange (ETDEWEB)

    Weavers, P; Shu, Y; Tao, S; Bernstein, M [Mayo Clinic, Rochester, Minnesota (United States); Lee, S; Piel, J; Foo, T [GE Global Research, Niskayuna, NY (United States); Mathieu, J-B [GE Healthcare, Florence, SC (Italy)

    2015-06-15

    Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

  3. TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

    International Nuclear Information System (INIS)

    Weavers, P; Shu, Y; Tao, S; Bernstein, M; Lee, S; Piel, J; Foo, T; Mathieu, J-B

    2015-01-01

    Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065

  4. Uniform gradient expansions

    CERN Document Server

    Giovannini, Massimo

    2015-01-01

    Cosmological singularities are often discussed by means of a gradient expansion that can also describe, during a quasi-de Sitter phase, the progressive suppression of curvature inhomogeneities. While the inflationary event horizon is being formed the two mentioned regimes coexist and a uniform expansion can be conceived and applied to the evolution of spatial gradients across the protoinflationary boundary. It is argued that conventional arguments addressing the preinflationary initial conditions are necessary but generally not sufficient to guarantee a homogeneous onset of the conventional inflationary stage.

  5. Gradient Flow Convolutive Blind Source Separation

    DEFF Research Database (Denmark)

    Pedersen, Michael Syskind; Nielsen, Chinton Møller

    2004-01-01

    Experiments have shown that the performance of instantaneous gradient flow beamforming by Cauwenberghs et al. is reduced significantly in reverberant conditions. By expanding the gradient flow principle to convolutive mixtures, separation in a reverberant environment is possible. By use...... of a circular four microphone array with a radius of 5 mm, and applying convolutive gradient flow instead of just applying instantaneous gradient flow, experimental results show an improvement of up to around 14 dB can be achieved for simulated impulse responses and up to around 10 dB for a hearing aid...

  6. An implicit tensorial gradient plasticity model - formulation and comparison with a scalar gradient model

    NARCIS (Netherlands)

    Poh, L.H.; Peerlings, R.H.J.; Geers, M.G.D.; Swaddiwudhipong, S.

    2011-01-01

    Many rate-independent models for metals utilize the gradient of effective plastic strain to capture size-dependent behavior. This enhancement, sometimes termed as "explicit" gradient formulation, requires higher-order tractions to be imposed on the evolving elasto-plastic boundary and the resulting

  7. High Gradient Accelerator Research

    International Nuclear Information System (INIS)

    Temkin, Richard

    2016-01-01

    The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave cold test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.

  8. SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    Science.gov (United States)

    Sheth, N; Chen, Y; Yang, J

    2012-06-01

    The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. Single isocenter intracranial SRS plans were created to treat the center of a solid water anthropomorphism head phantom for each GammaKnife collimator (4 mm, 8 mm, 14 mm, and 18 mm). The dose gradient, defined as the difference of effective radii of spheres equal to half and full Rx volumes, and Rx treatment volume was analyzed for isodoses from 99% to 20% of Rx. The dosimetric data on Rx volume and dose gradient vs. Rx isodose for each collimator was compiled into an easy to read nomogram as well as plotted graphically. The 4, 8, 14, and 18 mm collimators have the sharpest dose gradient at the 64%, 70%, 76%, and 77% Rx isodose lines, respectively. This corresponds to treating 4.77 mm, 8.86 mm, 14.78 mm, and 18.77 mm diameter targets with dose gradients radii of 1.06 mm, 1.63 mm, 2.54 mm, and 3.17 mm, respectively. We analyzed the dosimetric data for the most recent version of GammaPlan treatment planning software to develop tools that when applied clinically will aid in the selection of a collimator and Rx isodose line for optimal dose gradient and target coverage for single isocenter intracranial SRS with GammaKnife 4C. © 2012 American Association of Physicists in Medicine.

  9. Effects of Gradient Coil Noise and Gradient Coil Replacement on the Reproducibility of Resting State Networks.

    Science.gov (United States)

    Bagarinao, Epifanio; Tsuzuki, Erina; Yoshida, Yukina; Ozawa, Yohei; Kuzuya, Maki; Otani, Takashi; Koyama, Shuji; Isoda, Haruo; Watanabe, Hirohisa; Maesawa, Satoshi; Naganawa, Shinji; Sobue, Gen

    2018-01-01

    The stability of the MRI scanner throughout a given study is critical in minimizing hardware-induced variability in the acquired imaging data set. However, MRI scanners do malfunction at times, which could generate image artifacts and would require the replacement of a major component such as its gradient coil. In this article, we examined the effect of low intensity, randomly occurring hardware-related noise due to a faulty gradient coil on brain morphometric measures derived from T1-weighted images and resting state networks (RSNs) constructed from resting state functional MRI. We also introduced a method to detect and minimize the effect of the noise associated with a faulty gradient coil. Finally, we assessed the reproducibility of these morphometric measures and RSNs before and after gradient coil replacement. Our results showed that gradient coil noise, even at relatively low intensities, could introduce a large number of voxels exhibiting spurious significant connectivity changes in several RSNs. However, censoring the affected volumes during the analysis could minimize, if not completely eliminate, these spurious connectivity changes and could lead to reproducible RSNs even after gradient coil replacement.

  10. Tearing modes with pressure gradient effect in pair plasmas

    International Nuclear Information System (INIS)

    Cai Huishan; Li Ding; Zheng Jian

    2009-01-01

    The general dispersion relation of tearing mode with pressure gradient effect in pair plasmas is derived analytically. If the pressure gradients of positron and electron are not identical in pair plasmas, the pressure gradient has significant influence at tearing mode in both collisionless and collisional regimes. In collisionless regime, the effects of pressure gradient depend on its magnitude. For small pressure gradient, the growth rate of tearing mode is enhanced by pressure gradient. For large pressure gradient, the growth rate is reduced by pressure gradient. The tearing mode can even be stabilized if pressure gradient is large enough. In collisional regime, the growth rate of tearing mode is reduced by the pressure gradient. While the positron and electron have equal pressure gradient, tearing mode is not affected by pressure gradient in pair plasmas.

  11. Diffusion tensor imaging of the cortico-ponto-cerebellar pathway in patients with adult-onset ataxic neurodegenerative disease

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Kaeko; Nakayama, Keiko; Yamada, Eiji; Inoue, Yuichi [Osaka City University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Kosaka, Satoru; Shimada, Hiroyuki; Miki, Takami [Osaka City University Graduate School of Medicine, Department of Neurology, Osaka (Japan)

    2008-04-15

    We sought to determine whether diffusion-tensor imaging (DTI) can detect in vivo axonal damage in the corticopontocerebellar pathway of patients with adult-onset ataxic neurodegenerative disease. Conventional MRI and DTI were performed on 18 patients with adult-onset ataxic neurodegenerative disease and 28 age-matched control subjects. Fractional anisotropy (FA) and the mean diffusivity (MD) were measured in the ventral, central, and dorsal pons, middle cerebellar peduncle (MCP) and internal capsule to evaluate corticopontocerebellar projection. Changes in FA and MD values were compared between patients and controls. Clinical disability was assessed according to the International Cooperative Ataxia Rating Scale (ICARS). The relationship between DTI measurements and ICARS was studied. Follow-up MRI was performed in five patients approximately 1 year later. FA values were significantly lower in the ventral and central portions of the pons, MCP, and internal capsules than in these areas in control subjects (P < 0.05) with the lower FA values correlating with poorer ICARS (r > -0.57, P < 0.05). MD values were elevated in these areas, but the differences were smaller than for the FA values. No relationship was observed between the MD and ICARS. In the five patients who underwent the follow-up study, there were significant decreases between the initial study and the follow-up DTI study for FA in the MCP and internal capsule (P < 0.05). DTI can demonstrate a degenerated corticopontocerebellar pathway in patients, and FA values can be correlated with ataxia severity. DTI may be a clinically useful tool as a quantitative surrogate marker for monitoring disease progression. (orig.)

  12. Diffusion tensor imaging of the cortico-ponto-cerebellar pathway in patients with adult-onset ataxic neurodegenerative disease

    International Nuclear Information System (INIS)

    Kitamura, Kaeko; Nakayama, Keiko; Yamada, Eiji; Inoue, Yuichi; Kosaka, Satoru; Shimada, Hiroyuki; Miki, Takami

    2008-01-01

    We sought to determine whether diffusion-tensor imaging (DTI) can detect in vivo axonal damage in the corticopontocerebellar pathway of patients with adult-onset ataxic neurodegenerative disease. Conventional MRI and DTI were performed on 18 patients with adult-onset ataxic neurodegenerative disease and 28 age-matched control subjects. Fractional anisotropy (FA) and the mean diffusivity (MD) were measured in the ventral, central, and dorsal pons, middle cerebellar peduncle (MCP) and internal capsule to evaluate corticopontocerebellar projection. Changes in FA and MD values were compared between patients and controls. Clinical disability was assessed according to the International Cooperative Ataxia Rating Scale (ICARS). The relationship between DTI measurements and ICARS was studied. Follow-up MRI was performed in five patients approximately 1 year later. FA values were significantly lower in the ventral and central portions of the pons, MCP, and internal capsules than in these areas in control subjects (P -0.57, P < 0.05). MD values were elevated in these areas, but the differences were smaller than for the FA values. No relationship was observed between the MD and ICARS. In the five patients who underwent the follow-up study, there were significant decreases between the initial study and the follow-up DTI study for FA in the MCP and internal capsule (P < 0.05). DTI can demonstrate a degenerated corticopontocerebellar pathway in patients, and FA values can be correlated with ataxia severity. DTI may be a clinically useful tool as a quantitative surrogate marker for monitoring disease progression. (orig.)

  13. Evidence of counter-gradient growth in western pond turtles (Actinemys marmorata) across thermal gradients

    Science.gov (United States)

    Snover, Melissa; Adams, Michael J.; Ashton, Donald T.; Bettaso, Jamie B.; Welsh, Hartwell H.

    2015-01-01

    Counter-gradient growth, where growth per unit temperature increases as temperature decreases, can reduce the variation in ectothermic growth rates across environmental gradients. Understanding how ectothermic species respond to changing temperatures is essential to their conservation and management due to human-altered habitats and changing climates.

  14. DWI-based neural fingerprinting technology: a preliminary study on stroke analysis.

    Science.gov (United States)

    Ye, Chenfei; Ma, Heather Ting; Wu, Jun; Yang, Pengfei; Chen, Xuhui; Yang, Zhengyi; Ma, Jingbo

    2014-01-01

    Stroke is a common neural disorder in neurology clinics. Magnetic resonance imaging (MRI) has become an important tool to assess the neural physiological changes under stroke, such as diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI). Quantitative analysis of MRI images would help medical doctors to localize the stroke area in the diagnosis in terms of structural information and physiological characterization. However, current quantitative approaches can only provide localization of the disorder rather than measure physiological variation of subtypes of ischemic stroke. In the current study, we hypothesize that each kind of neural disorder would have its unique physiological characteristics, which could be reflected by DWI images on different gradients. Based on this hypothesis, a DWI-based neural fingerprinting technology was proposed to classify subtypes of ischemic stroke. The neural fingerprint was constructed by the signal intensity of the region of interest (ROI) on the DWI images under different gradients. The fingerprint derived from the manually drawn ROI could classify the subtypes with accuracy 100%. However, the classification accuracy was worse when using semiautomatic and automatic method in ROI segmentation. The preliminary results showed promising potential of DWI-based neural fingerprinting technology in stroke subtype classification. Further studies will be carried out for enhancing the fingerprinting accuracy and its application in other clinical practices.

  15. Multimodal image registration based on binary gradient angle descriptor.

    Science.gov (United States)

    Jiang, Dongsheng; Shi, Yonghong; Yao, Demin; Fan, Yifeng; Wang, Manning; Song, Zhijian

    2017-12-01

    Multimodal image registration plays an important role in image-guided interventions/therapy and atlas building, and it is still a challenging task due to the complex intensity variations in different modalities. The paper addresses the problem and proposes a simple, compact, fast and generally applicable modality-independent binary gradient angle descriptor (BGA) based on the rationale of gradient orientation alignment. The BGA can be easily calculated at each voxel by coding the quadrant in which a local gradient vector falls, and it has an extremely low computational complexity, requiring only three convolutions, two multiplication operations and two comparison operations. Meanwhile, the binarized encoding of the gradient orientation makes the BGA more resistant to image degradations compared with conventional gradient orientation methods. The BGA can extract similar feature descriptors for different modalities and enable the use of simple similarity measures, which makes it applicable within a wide range of optimization frameworks. The results for pairwise multimodal and monomodal registrations between various images (T1, T2, PD, T1c, Flair) consistently show that the BGA significantly outperforms localized mutual information. The experimental results also confirm that the BGA can be a reliable alternative to the sum of absolute difference in monomodal image registration. The BGA can also achieve an accuracy of [Formula: see text], similar to that of the SSC, for the deformable registration of inhale and exhale CT scans. Specifically, for the highly challenging deformable registration of preoperative MRI and 3D intraoperative ultrasound images, the BGA achieves a similar registration accuracy of [Formula: see text] compared with state-of-the-art approaches, with a computation time of 18.3 s per case. The BGA improves the registration performance in terms of both accuracy and time efficiency. With further acceleration, the framework has the potential for

  16. STOCHASTIC GRADIENT METHODS FOR UNCONSTRAINED OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    Nataša Krejić

    2014-12-01

    Full Text Available This papers presents an overview of gradient based methods for minimization of noisy functions. It is assumed that the objective functions is either given with error terms of stochastic nature or given as the mathematical expectation. Such problems arise in the context of simulation based optimization. The focus of this presentation is on the gradient based Stochastic Approximation and Sample Average Approximation methods. The concept of stochastic gradient approximation of the true gradient can be successfully extended to deterministic problems. Methods of this kind are presented for the data fitting and machine learning problems.

  17. Spatial gradient tuning in metamaterials

    Science.gov (United States)

    Driscoll, Tom; Goldflam, Michael; Jokerst, Nan; Basov, Dimitri; Smith, David

    2011-03-01

    Gradient Index (GRIN) metamaterials have been used to create devices inspired by, but often surpassing the potential of, conventional GRIN optics. The unit-cell nature of metamaterials presents the opportunity to exert much greater control over spatial gradients than is possible in natural materials. This is true not only during the design phase but also offers the potential for real-time reconfiguration of the metamaterial gradient. This ability fits nicely into the picture of transformation-optics, in which spatial gradients can enable an impressive suite of innovative devices. We discuss methods to exert control over metamaterial response, focusing on our recent demonstrations using Vanadium Dioxide. We give special attention to role of memristance and mem-capacitance observed in Vanadium Dioxide, which simplify the demands of stimuli and addressing, as well as intersecting metamaterials with the field of memory-materials.

  18. Approximate error conjugation gradient minimization methods

    Science.gov (United States)

    Kallman, Jeffrey S

    2013-05-21

    In one embodiment, a method includes selecting a subset of rays from a set of all rays to use in an error calculation for a constrained conjugate gradient minimization problem, calculating an approximate error using the subset of rays, and calculating a minimum in a conjugate gradient direction based on the approximate error. In another embodiment, a system includes a processor for executing logic, logic for selecting a subset of rays from a set of all rays to use in an error calculation for a constrained conjugate gradient minimization problem, logic for calculating an approximate error using the subset of rays, and logic for calculating a minimum in a conjugate gradient direction based on the approximate error. In other embodiments, computer program products, methods, and systems are described capable of using approximate error in constrained conjugate gradient minimization problems.

  19. Gravity gradient preprocessing at the GOCE HPF

    Science.gov (United States)

    Bouman, J.; Rispens, S.; Gruber, T.; Schrama, E.; Visser, P.; Tscherning, C. C.; Veicherts, M.

    2009-04-01

    One of the products derived from the GOCE observations are the gravity gradients. These gravity gradients are provided in the Gradiometer Reference Frame (GRF) and are calibrated in-flight using satellite shaking and star sensor data. In order to use these gravity gradients for application in Earth sciences and gravity field analysis, additional pre-processing needs to be done, including corrections for temporal gravity field signals to isolate the static gravity field part, screening for outliers, calibration by comparison with existing external gravity field information and error assessment. The temporal gravity gradient corrections consist of tidal and non-tidal corrections. These are all generally below the gravity gradient error level, which is predicted to show a 1/f behaviour for low frequencies. In the outlier detection the 1/f error is compensated for by subtracting a local median from the data, while the data error is assessed using the median absolute deviation. The local median acts as a high-pass filter and it is robust as is the median absolute deviation. Three different methods have been implemented for the calibration of the gravity gradients. All three methods use a high-pass filter to compensate for the 1/f gravity gradient error. The baseline method uses state-of-the-art global gravity field models and the most accurate results are obtained if star sensor misalignments are estimated along with the calibration parameters. A second calibration method uses GOCE GPS data to estimate a low degree gravity field model as well as gravity gradient scale factors. Both methods allow to estimate gravity gradient scale factors down to the 10-3 level. The third calibration method uses high accurate terrestrial gravity data in selected regions to validate the gravity gradient scale factors, focussing on the measurement band. Gravity gradient scale factors may be estimated down to the 10-2 level with this method.

  20. Associations between clinical outcome and navigated transcranial magnetic stimulation characteristics in patients with motor-eloquent brain lesions: a combined navigated transcranial magnetic stimulation-diffusion tensor imaging fiber tracking approach.

    Science.gov (United States)

    Sollmann, Nico; Wildschuetz, Noémie; Kelm, Anna; Conway, Neal; Moser, Tobias; Bulubas, Lucia; Kirschke, Jan S; Meyer, Bernhard; Krieg, Sandro M

    2018-03-01

    This is one of the first studies to show a direct correlation between imaging, clinical status, and neurophysiological markers for the integrity of the motor system in patients with brain tumors. The findings suggest that nTMS-based DTI FT might be suitable for individual risk assessment in patients with HGG, in addition to being a surgery-planning tool. Importantly, necessary data for risk assessment were obtained without significant additional efforts, making this approach potentially valuable for direct clinical use.

  1. The disparate impact of the ion temperature gradient and the density gradient on edge transport and the low-high transition in tokamaks

    International Nuclear Information System (INIS)

    Kleva, Robert G.; Guzdar, Parvez N.

    2009-01-01

    Steepening of the ion temperature gradient in nonlinear fluid simulations of the edge region of a tokamak plasma causes a rapid degradation in confinement. As the density gradient steepens, there is a continuous improvement in confinement analogous to the low (L) to high (H) transition observed in tokamaks. In contrast, as the ion temperature gradient steepens, there is a rapid increase in the particle and energy fluxes and no L-H transition. For a given pressure gradient, confinement always improves when more of the pressure gradient arises from the density gradient, and less of the pressure gradient arises from the ion temperature gradient.

  2. Bone marrow-derived cells for cardiovascular cell therapy: an optimized GMP method based on low-density gradient improves cell purity and function.

    Science.gov (United States)

    Radrizzani, Marina; Lo Cicero, Viviana; Soncin, Sabrina; Bolis, Sara; Sürder, Daniel; Torre, Tiziano; Siclari, Francesco; Moccetti, Tiziano; Vassalli, Giuseppe; Turchetto, Lucia

    2014-09-27

    Cardiovascular cell therapy represents a promising field, with several approaches currently being tested. The advanced therapy medicinal product (ATMP) for the ongoing METHOD clinical study ("Bone marrow derived cell therapy in the stable phase of chronic ischemic heart disease") consists of fresh mononuclear cells (MNC) isolated from autologous bone marrow (BM) through density gradient centrifugation on standard Ficoll-Paque. Cells are tested for safety (sterility, endotoxin), identity/potency (cell count, CD45/CD34/CD133, viability) and purity (contaminant granulocytes and platelets). BM-MNC were isolated by density gradient centrifugation on Ficoll-Paque. The following process parameters were optimized throughout the study: gradient medium density; gradient centrifugation speed and duration; washing conditions. A new manufacturing method was set up, based on gradient centrifugation on low density Ficoll-Paque, followed by 2 washing steps, of which the second one at low speed. It led to significantly higher removal of contaminant granulocytes and platelets, improving product purity; the frequencies of CD34+ cells, CD133+ cells and functional hematopoietic and mesenchymal precursors were significantly increased. The methodological optimization described here resulted in a significant improvement of ATMP quality, a crucial issue to clinical applications in cardiovascular cell therapy.

  3. Clinical functional MRI. Persurgical functional neuroimaging. 2. ed.

    International Nuclear Information System (INIS)

    Stippich, Christoph

    2015-01-01

    The second, revised edition of this successful textbook provides an up-to-date description of the use of preoperative fMRI in patients with brain tumors and epilepsies. State of the art fMRI procedures are presented, with detailed consideration of practical aspects, imaging and data processing, normal and pathological findings, and diagnostic possibilities and limitations. Relevant information on brain physiology, functional neuroanatomy, imaging technique, and methodology is provided by recognized experts in these fields. Compared with the first edition, chapters have been updated to reflect the latest developments and in particular the current use of diffusion tensor imaging (DTI) and resting-state fMRI. Entirely new chapters are included on resting-state presurgical fMRI and the role of DTI and tractography in brain tumor surgery. Further chapters address multimodality functional neuroimaging, brain plasticity, and pitfalls, tips, and tricks.

  4. Clinical functional MRI. Persurgical functional neuroimaging. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stippich, Christoph (ed.) [Univ. Hospitals Basel (Switzerland). Division of Diagnostic and Inventional Neuroradiology

    2015-06-01

    The second, revised edition of this successful textbook provides an up-to-date description of the use of preoperative fMRI in patients with brain tumors and epilepsies. State of the art fMRI procedures are presented, with detailed consideration of practical aspects, imaging and data processing, normal and pathological findings, and diagnostic possibilities and limitations. Relevant information on brain physiology, functional neuroanatomy, imaging technique, and methodology is provided by recognized experts in these fields. Compared with the first edition, chapters have been updated to reflect the latest developments and in particular the current use of diffusion tensor imaging (DTI) and resting-state fMRI. Entirely new chapters are included on resting-state presurgical fMRI and the role of DTI and tractography in brain tumor surgery. Further chapters address multimodality functional neuroimaging, brain plasticity, and pitfalls, tips, and tricks.

  5. Clinical characteristics in normal healthy adults with microbleeds on echo-planar gradient-echo T2*-weighted MRI

    International Nuclear Information System (INIS)

    Takahashi, Wakoh; Ide, Michiru; Ohnuki, Tomohide; Takagi, Shigeharu; Shinohara, Yukito

    2004-01-01

    The gradient-echo T 2 * -weighted sequence in magnetic resonance imaging is known to be useful for detecting microbleeds (MBs) in patients with intracranial hemorrhage or lacunar stroke. We investigated the characteristics of apparently healthy adults with MBs but without stroke, employing echo-planar gradient-echo T 2 * -weighted MRI. The subjects were recruited from among 3,537 participants who underwent brain check-ups at the HIMEDIC Imaging Center. Of the 3,537 participants, 3,296 (mean age, 55±11 years) without any history of cerebrovascular disease or apparent focal neurological manifestations were selected for the present study. MBs on echo-planar gradient-echo T 2 * -weighted MRI were observed in 74 (2.2%) of the 3,296 subjects. Of a total of 133 lesions found in these 74 persons, 31 were located in the basal ganglia or cortico-subcortical regions. Thirty were in the deep white matter, 19 in the thalamus, 16 in the cerebellum, and 6 in the brain stem. The subjects with MBs were significantly older than the subjects without MBs, and the mean values for their systolic and diastolic blood pressures were higher than those in the subjects without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs, as compared with those without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs of the basal ganglia or thalamus than in those with MBs in other regions. MBs on echo-planar gradient-echo T 2 * -weighted MRI were thus relatively rare in apparently healthy adults. However, MBs in the basal ganglia or thalamus are suggested to be closely related to intracerebral microangiopathy. Persons with MBs in such regions should therefore be carefully checked for cerebrovascular risk

  6. Is there a rural gradient in the diagnosis of aortic stenosis? An analysis of a remote Scottish cohort.

    Science.gov (United States)

    Maycock, Matthew I; Farman, Colin; Mort, Alasdair; Turpie, David; Leslie, Stephen J

    2013-01-01

    Calcific aortic stenosis is the most common cardiac valve lesion and is becoming increasingly prevalent as life expectancy rises. There is evidence that patients in remote and rural areas with certain diseases have worse outcomes and present to specialist services later than their urban counterparts. It is not known whether patients with aortic stenosis follow a similar pattern. The aim of this study was to investigate whether increasing rurality was associated with later presentation to healthcare services at a more advanced stage of aortic stenosis. This was a retrospective cohort study. Using ICD-10 discharge codes and local databases, 605 patients with aortic stenosis who presented between 31 November 1999 and 1 December 2008 were identified. Aortic stenosis was defined as a pressure gradient across the aortic valve of 25 mmHg or more. Patients with prior aortic valve replacement were excluded. Clinical notes were reviewed for all patients. Gender, age and pressure gradient across the aortic valve at presentation and patient GP-practice location were recorded. Patients were then assigned a Clinical Peripherality Index score based on the postcode of their GP's practice to define rurality. Patient data were compared across the six defined levels of clinical peripherality by ANOVA. Mean patient age was 73 ± 13 years, and 336 (54%) were male. The peak gradient across the valve was 41.1 ± 26.7 mmHg. There was no association between the level of clinical peripherality and the stage of aortic stenosis at presentation, age or gender (all p >0.05). There was no urban-rural gradient in the severity of aortic stenosis at presentation in this remote Scottish cohort. This suggests that patients with this condition in remote areas do not present later in their disease trajectory.

  7. Intracellular chemical gradients: morphing principle in bacteria

    Directory of Open Access Journals (Sweden)

    Endres Robert G

    2012-09-01

    Full Text Available Abstract Advances in computational biology allow systematic investigations to ascertain whether internal chemical gradients can be maintained in bacteria – an open question at the resolution limit of fluorescence microscopy. While it was previously believed that the small bacterial cell size and fast diffusion in the cytoplasm effectively remove any such gradient, a new computational study published in BMC Biophysics supports the emerging view that gradients can exist. The study arose from the recent observation that phosphorylated CtrA forms a gradient prior to cell division in Caulobacter crescentus, a bacterium known for its complicated cell cycle. Tropini et al. (2012 postulate that such gradients can provide an internal chemical compass, directing protein localization, cell division and cell development. More specifically, they describe biochemical and physical constraints on the formation of such gradients and explore a number of existing bacterial cell morphologies. These chemical gradients may limit in vitro analyses, and may ensure timing control and robustness to fluctuations during critical stages in cell development.

  8. Protein gradient films of fibroin and gelatine.

    Science.gov (United States)

    Claussen, Kai U; Lintz, Eileen S; Giesa, Reiner; Schmidt, Hans-Werner; Scheibel, Thomas

    2013-10-01

    Gradients are a natural design principle in biological systems that are used to diminish stress concentration where materials of differing mechanical properties connect. An interesting example of a natural gradient material is byssus, which anchors mussels to rocks and other hard substrata. Building upon previous work with synthetic polymers and inspired by byssal threads, protein gradient films are cast using glycerine-plasticized gelatine and fibroin exhibiting a highly reproducible and smooth mechanical gradient, which encompasses a large range of modulus from 160 to 550 MPa. The reproducible production of biocompatible gradient films represents a first step towards medical applications. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Characterization of gradient control systems

    NARCIS (Netherlands)

    Cortés, Jorge; van der Schaft, Arjan; Crouch, Peter E.

    2005-01-01

    Given a general nonlinear affine control system with outputs and a torsion-free affine connection defined on its state space, we investigate the gradient realization problem: we give necessary and sufficient conditions under which the control system can be written as a gradient control system

  10. Characterization of Gradient Control Systems

    NARCIS (Netherlands)

    Cortés, Jorge; Schaft, Arjan van der; Crouch, Peter E.

    2005-01-01

    Given a general nonlinear affine control system with outputs and a torsion-free affine connection defined on its state space, we investigate the gradient realization problem: we give necessary and sufficient conditions under which the control system can be written as a gradient control system

  11. Quaternion Gradient and Hessian

    OpenAIRE

    Xu, Dongpo; Mandic, Danilo P.

    2014-01-01

    The optimization of real scalar functions of quaternion variables, such as the mean square error or array output power, underpins many practical applications. Solutions typically require the calculation of the gradient and Hessian. However, real functions of quaternion variables are essentially nonanalytic, which are prohibitive to the development of quaternion-valued learning systems. To address this issue, we propose new definitions of quaternion gradient and Hessian, based on the novel gen...

  12. Cell orientation gradients on an inverse opal substrate.

    Science.gov (United States)

    Lu, Jie; Zou, Xin; Zhao, Ze; Mu, Zhongde; Zhao, Yuanjin; Gu, Zhongze

    2015-05-20

    The generation of cell gradients is critical for understanding many biological systems and realizing the unique functionality of many implanted biomaterials. However, most previous work can only control the gradient of cell density and this has no effect on the gradient of cell orientation, which has an important role in regulating the functions of many connecting tissues. Here, we report on a simple stretched inverse opal substrate for establishing desired cell orientation gradients. It was demonstrated that tendon fibroblasts on the stretched inverse opal gradient showed a corresponding alignment along with the elongation gradient of the substrate. This "random-to-aligned" cell gradient reproduces the insertion part of many connecting tissues, and thus, will have important applications in tissue engineering.

  13. Jupiter's evolution with primordial composition gradients

    Science.gov (United States)

    Vazan, Allona; Helled, Ravit; Guillot, Tristan

    2018-02-01

    Recent formation and structure models of Jupiter suggest that the planet can have composition gradients and not be fully convective (adiabatic). This possibility directly affects our understanding of Jupiter's bulk composition and origin. In this Letter we present Jupiter's evolution with a primordial structure consisting of a relatively steep heavy-element gradient of 40 M⊕. We show that for a primordial structure with composition gradients, most of the mixing occurs in the outer part of the gradient during the early evolution (several 107 yr), leading to an adiabatic outer envelope (60% of Jupiter's mass). We find that the composition gradient in the deep interior persists, suggesting that 40% of Jupiter's mass can be non-adiabatic with a higher temperature than the one derived from Jupiter's atmospheric properties. The region that can potentially develop layered convection in Jupiter today is estimated to be limited to 10% of the mass. Movies associated to Figs. 1-3 are available at http://https://www.aanda.org

  14. Dexamethasone concentration gradients along scala tympani after application to the round window membrane.

    Science.gov (United States)

    Plontke, Stefan K; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Salt, Alec N

    2008-04-01

    substantial basal-apical concentration gradients of Dex-P in ST perilymph were demonstrated experimentally. If the variability in peak concentration and gradient is also present under clinical conditions, this may contribute to the heterogeneity of outcome that is observed after intratympanic application of glucocorticoids for various inner ear diseases.

  15. Frequency Analysis of Gradient Estimators in Volume Rendering

    NARCIS (Netherlands)

    Bentum, Marinus Jan; Lichtenbelt, Barthold B.A.; Malzbender, Tom

    1996-01-01

    Gradient information is used in volume rendering to classify and color samples along a ray. In this paper, we present an analysis of the theoretically ideal gradient estimator and compare it to some commonly used gradient estimators. A new method is presented to calculate the gradient at arbitrary

  16. Instabilities in power law gradient hardening materials

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Tvergaard, Viggo

    2005-01-01

    Tension and compression instabilities are investigated for specimens with dimensions in the micron range. A finite strain generalization of a higher order strain gradient plasticity theory is implemented in a finite element scheme capable of modeling power law hardening materials. Effects...... of gradient hardening are found to delay the onset of localization under plane strain tension, and significantly reduce strain gradients in the localized zone. For plane strain compression gradient hardening is found to increase the load-carrying capacity significantly....

  17. Utilization of a pressure sensor guidewire to measure bileaflet mechanical valve gradients: hemodynamic and echocardiographic sequelae.

    Science.gov (United States)

    Doorey, Andrew J; Gakhal, Mandip; Pasquale, Michael J

    2006-04-01

    Suspected prosthetic valve dysfunction is a difficult clinical problem, because of the high risk of repeat valvular surgery. Echocardiographic measurements of prosthetic valvular dysfunction can be misleading, especially with bileaflet valves. Direct measurement of trans-valvular gradients is problematic because of potentially serious catheter entrapment issues. We report a case in which a high-fidelity pressure sensor angioplasty guidewire was used to cross prosthetic mitral and aortic valves in a patient, with hemodynamic and echocardiographic assessment. This technique was safe and effective, refuting the inaccurate non-invasive tests that over-estimated the aortic valvular gradient.

  18. Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: Evaluation using a diffusional anisotropic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Joon; Choi, Choong Gon; Kim, Jeong Kon [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yun, Sung Cheol [Dept. of Biostatistics, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Jeong, Ha Kyu [Dept. of Radiology, East-West Neomedical Center, Kyung Hee University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Ju [Clinical Scientist, MR, Philips Healthcare, Seoul (Korea, Republic of)

    2015-04-15

    To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis. The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value. A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies.

  19. Self-induced temperature gradients in Brownian dynamics

    Science.gov (United States)

    Devine, Jack; Jack, M. W.

    2017-12-01

    Brownian systems often surmount energy barriers by absorbing and emitting heat to and from their local environment. Usually, the temperature gradients created by this heat exchange are assumed to dissipate instantaneously. Here we relax this assumption to consider the case where Brownian dynamics on a time-independent potential can lead to self-induced temperature gradients. In the same way that externally imposed temperature gradients can cause directed motion, these self-induced gradients affect the dynamics of the Brownian system. The result is a coupling between the local environment and the Brownian subsystem. We explore the resulting dynamics and thermodynamics of these coupled systems and develop a robust method for numerical simulation. In particular, by focusing on one-dimensional situations, we show that self-induced temperature gradients reduce barrier-crossing rates. We also consider a heat engine and a heat pump based on temperature gradients induced by a Brownian system in a nonequilibrium potential.

  20. Up-gradient transport in a probabilistic transport model

    DEFF Research Database (Denmark)

    Gavnholt, J.; Juul Rasmussen, J.; Garcia, O.E.

    2005-01-01

    The transport of particles or heat against the driving gradient is studied by employing a probabilistic transport model with a characteristic particle step length that depends on the local concentration or heat gradient. When this gradient is larger than a prescribed critical value, the standard....... These results supplement recent works by van Milligen [Phys. Plasmas 11, 3787 (2004)], which applied Levy distributed step sizes in the case of supercritical gradients to obtain the up-gradient transport. (c) 2005 American Institute of Physics....

  1. Elemental gradients in macrophytes from a reactor effluent gradient

    International Nuclear Information System (INIS)

    Grace, J.B.; Tilly, L.J.

    1978-01-01

    The tissues of submersed macrophtes from along the thermal gradient were analyzed for phosphorus to determine whether any pattern correspondent to standing crop distributions could be detected. Although water concentrations of phosphorus showed no detectable relationship to the thermal effluent, tissue concentrations of this element in submersed macrophytes declined with distance from the effluent entry point. The occurrence of this concentration pattern suggests that phosphorus availability is greater near the discharge. Because phosphorus is the element most often determined to limit aquatic productivity, its greater availability may partially account for the apparent enhancement of macrophte growth near the thermal discharge. A patter of macrophyte abundance which indicated enchancement related to the discharge gradient in the reactor-cooling reservoir, Par Pond is reported. Correlative data tended to implicate light and temperature as important in influencing the differential abundance pattern

  2. An education gradient in health, a health gradient in education, or a confounded gradient in both?

    Science.gov (United States)

    Lynch, Jamie L; von Hippel, Paul T

    2016-04-01

    There is a positive gradient associating educational attainment with health, yet the explanation for this gradient is not clear. Does higher education improve health (causation)? Do the healthy become highly educated (selection)? Or do good health and high educational attainment both result from advantages established early in the life course (confounding)? This study evaluates these competing explanations by tracking changes in educational attainment and Self-rated Health (SRH) from age 15 to age 31 in the National Longitudinal Study of Youth, 1997 cohort. Ordinal logistic regression confirms that high-SRH adolescents are more likely to become highly educated. This is partly because adolescent SRH is associated with early advantages including adolescents' academic performance, college plans, and family background (confounding); however, net of these confounders adolescent SRH still predicts adult educational attainment (selection). Fixed-effects longitudinal regression shows that educational attainment has little causal effect on SRH at age 31. Completion of a high school diploma or associate's degree has no effect on SRH, while completion of a bachelor's or graduate degree have effects that, though significant, are quite small (less than 0.1 points on a 5-point scale). While it is possible that educational attainment would have greater effect on health at older ages, at age 31 what we see is a health gradient in education, shaped primarily by selection and confounding rather than by a causal effect of education on health. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Extended Erythropoietin Treatment Prevents Chronic Executive Functional and Microstructural Deficits Following Early Severe Traumatic Brain Injury in Rats

    Directory of Open Access Journals (Sweden)

    Shenandoah Robinson

    2018-06-01

    Full Text Available Survivors of infant traumatic brain injury (TBI are prone to chronic neurological deficits that impose lifelong individual and societal burdens. Translation of novel interventions to clinical trials is hampered in part by the lack of truly representative preclinical tests of cognition and corresponding biomarkers of functional outcomes. To address this gap, the ability of a high-dose, extended, post-injury regimen of erythropoietin (EPO, 3000U/kg/dose × 6d to prevent chronic cognitive and imaging deficits was tested in a postnatal day 12 (P12 controlled-cortical impact (CCI model in rats, using touchscreen operant chambers and regional analysis of diffusion tensor imaging (DTI. Results indicate that EPO prevents functional injury and MRI injury after infant TBI. Specifically, subacute DTI at P30 revealed widespread microstructural damage that is prevented by EPO. Assessment of visual discrimination on a touchscreen operant chamber platform demonstrated that all groups can perform visual discrimination. However, CCI rats treated with vehicle failed to pass reversal learning, and perseverated, in contrast to sham and CCI-EPO rats. Chronic DTI at P90 showed EPO treatment prevented contralateral white matter and ipsilateral lateral prefrontal cortex damage. This DTI improvement correlated with cognitive performance. Taken together, extended EPO treatment restores executive function and prevents microstructural brain abnormalities in adult rats with cognitive deficits in a translational preclinical model of infant TBI. Sophisticated testing with touchscreen operant chambers and regional DTI analyses may expedite translation and effective yield of interventions from preclinical studies to clinical trials. Collectively, these data support the use of EPO in clinical trials for human infants with TBI.

  4. Electric field gradients in metals

    International Nuclear Information System (INIS)

    Schatz, G.

    1979-01-01

    A review of the recent works on electric field gradient in metals is given. The main emphasis is put on the temperature dependence of the electric field gradient in nonmagnetic metals. Some methods of investigation of this effect using nuclear probes are described. One of them is nuclear accoustic resonance method. (S.B.)

  5. Ponderomotive force effects on temperature-gradient-driven instabilities

    International Nuclear Information System (INIS)

    Sundaram, A.K.; Hershkowitz, N.

    1992-01-01

    The modification of temperature-gradient-driven instabilities due to the presence of nonuniform radio-frequency fields near the ion cyclotron frequency is investigated in the linear regime. Employing the fluid theory, it is shown that the induced field line compression caused by ion cyclotron range of frequencies (ICRF) fields makes the net parallel compressibility positive, and thus provides a stabilizing influence on the ion-temperature-gradient-driven mode for an appropriately tailored profile of radio-frequency (rf) pressure. Concomitantly, the radial ponderomotive force generates an additional contribution via coupling between the perturbed fluid motion and the equilibrium ponderomotive force and this effect plays the role of dissipation to enhance or decrease the growth of temperature-gradient-driven modes depending upon the sign of rf pressure gradients. For decreased growth of temperature-gradient-driven instabilities, the plasma density gradients and rf pressure gradients must have opposite signs while enhancement in growth arises when both gradients have the same sign. Finally, the kinetic effects associated with these modes are briefly discussed

  6. Substrate-Bound Protein Gradients to Study Haptotaxis

    Directory of Open Access Journals (Sweden)

    Sebastien G. Ricoult

    2015-03-01

    Full Text Available Cells navigate in response to inhomogeneous distributions of extracellular guidance cues. The cellular and molecular mechanisms underlying migration in response to gradients of chemical cues have been investigated for over a century. Following the introduction of micropipettes and more recently microfluidics for gradient generation, much attention and effort was devoted to study cellular chemotaxis, which is defined as guidance by gradients of chemical cues in solution. Haptotaxis, directional migration in response to gradients of substrate-bound cues, has received comparatively less attention; however it is increasingly clear that in vivo many physiologically relevant guidance proteins – including many secreted cues – are bound to cellular surfaces or incorporated into extracellular matrix and likely function via a haptotactic mechanism. Here, we review the history of haptotaxis. We examine the importance of the reference surface, the surface in contact with the cell that is not covered by the cue, which forms a gradient opposing the gradient of the protein cue and must be considered in experimental designs and interpretation of results. We review and compare microfluidics, contact-printing, light patterning and 3D fabrication to pattern substrate-bound protein gradients in vitro, and focus on their application to study axon guidance. The range of methods to create substrate-bound gradients discussed herein make possible systematic analyses of haptotactic mechanisms. Furthermore, understanding the fundamental mechanisms underlying cell motility will inform bioengineering approaches to program cell navigation and recover lost function.

  7. Role of spatial averaging in multicellular gradient sensing.

    Science.gov (United States)

    Smith, Tyler; Fancher, Sean; Levchenko, Andre; Nemenman, Ilya; Mugler, Andrew

    2016-05-20

    Gradient sensing underlies important biological processes including morphogenesis, polarization, and cell migration. The precision of gradient sensing increases with the length of a detector (a cell or group of cells) in the gradient direction, since a longer detector spans a larger range of concentration values. Intuition from studies of concentration sensing suggests that precision should also increase with detector length in the direction transverse to the gradient, since then spatial averaging should reduce the noise. However, here we show that, unlike for concentration sensing, the precision of gradient sensing decreases with transverse length for the simplest gradient sensing model, local excitation-global inhibition. The reason is that gradient sensing ultimately relies on a subtraction of measured concentration values. While spatial averaging indeed reduces the noise in these measurements, which increases precision, it also reduces the covariance between the measurements, which results in the net decrease in precision. We demonstrate how a recently introduced gradient sensing mechanism, regional excitation-global inhibition (REGI), overcomes this effect and recovers the benefit of transverse averaging. Using a REGI-based model, we compute the optimal two- and three-dimensional detector shapes, and argue that they are consistent with the shapes of naturally occurring gradient-sensing cell populations.

  8. Community and ecosystem responses to elevational gradients

    DEFF Research Database (Denmark)

    Sundqvist, Maja K.; Sanders, Nate; Wardle, David A.

    2013-01-01

    Community structure and ecosystem processes often vary along elevational gradients. Their responses to elevation are commonly driven by changes in temperature, and many community- and ecosystem-level variables therefore frequently respond similarly to elevation across contrasting gradients...... elevational gradients for understanding community and ecosystem responses to global climate change at much larger spatial and temporal scales than is possible through conventional ecological experiments. However, future studies that integrate elevational gradient approaches with experimental manipulations...... will provide powerful information that can improve predictions of climate change impacts within and across ecosystems....

  9. Noninvasive prenatal diagnosis. Use of density gradient centrifugation, magnetically activated cell sorting and in situ hybridization

    DEFF Research Database (Denmark)

    Campagnoli, C; Multhaupt, H A; Ludomirski, A

    1997-01-01

    OBJECTIVE: To develop a noninvasive method suitable for clinical prenatal diagnosis. STUDY DESIGN: Fetal nucleated erythrocytes were separated from peripheral blood of 17 healthy pregnant women using small magnetically activated cell sorting columns (MiniMACS) following density gradient centrifug...

  10. ZOOM or Non-ZOOM? Assessing Spinal Cord Diffusion Tensor Imaging Protocols for Multi-Centre Studies.

    Directory of Open Access Journals (Sweden)

    Rebecca S Samson

    Full Text Available The purpose of this study was to develop and evaluate two spinal cord (SC diffusion tensor imaging (DTI protocols, implemented at multiple sites (using scanners from two different manufacturers, one available on any clinical scanner, and one using more advanced options currently available in the research setting, and to use an automated processing method for unbiased quantification. DTI parameters are sensitive to changes in the diseased SC. However, imaging the cord can be technically challenging due to various factors including its small size, patient-related and physiological motion, and field inhomogeneities. Rapid acquisition sequences such as Echo Planar Imaging (EPI are desirable but may suffer from image distortions. We present a multi-centre comparison of two acquisition protocols implemented on scanners from two different vendors (Siemens and Philips, one using a reduced field-of-view (rFOV EPI sequence, and one only using options available on standard clinical scanners such as outer volume suppression (OVS. Automatic analysis was performed with the Spinal Cord Toolbox for unbiased and reproducible quantification of DTI metrics in the white matter. Images acquired using the rFOV sequence appear less distorted than those acquired using OVS alone. SC DTI parameter values obtained using both sequences at all sites were consistent with previous measurements made at 3T. For the same scanner manufacturer, DTI parameter inter-site SDs were smaller for the rFOV sequence compared to the OVS sequence. The higher inter-site reproducibility (for the same manufacturer and acquisition details, i.e. ZOOM data acquired at the two Philips sites of rFOV compared to the OVS sequence supports the idea that making research options such as rFOV more widely available would improve accuracy of measurements obtained in multi-centre clinical trials. Future multi-centre studies should also aim to match the rFOV technique and signal-to-noise ratios in all

  11. Gradient remediability in linear distributed parabolic systems ...

    African Journals Online (AJOL)

    The aim of this paper is the introduction of a new concept that concerned the analysis of a large class of distributed parabolic systems. It is the general concept of gradient remediability. More precisely, we study with respect to the gradient observation, the existence of an input operator (gradient efficient actuators) ensuring ...

  12. Structural and compositional gradients: basic idea, preparation, applications

    International Nuclear Information System (INIS)

    Ilschner, B.

    1993-01-01

    The term gradient materials refers to gradients of chemical composition and/or microstructural parameters which are intentionally introduced into components of any kind of homogeneous or heterogeneous materials, including metallic alloys, ceramics, glasses, polymers, and composites. After a short review of the development of the gradient materials technology since 1972, some fundamental aspects concerning the effects of such gradients on physical or mechanical properties are discussed. A selection of technical applications which have been discussed recently is presented. Finally, different methods for the preparation of gradients from gaseous, liquid or powder precursors are reviewed. (orig.)

  13. Thermal conduction down steep temperature gradients

    International Nuclear Information System (INIS)

    Bell, A.R.; Evans, R.G.; Nicholas, D.J.

    1980-08-01

    The Fokker-Planck equation has been solved numerically in one spatial and two velocity dimensions in order to study thermal conduction in large temperature gradients. An initially cold plasma is heated at one end of the spatial grid producing temperature gradients with scale lengths of a few times the electron mean free path. The heat flow is an order of magnitude smaller than that predicted by the classical theory which is valid in the limit of small temperature gradients. (author)

  14. High gradient superconducting quadrupoles

    International Nuclear Information System (INIS)

    Lundy, R.A.; Brown, B.C.; Carson, J.A.; Fisk, H.E.; Hanft, R.H.; Mantsch, P.M.; McInturff, A.D.; Remsbottom, R.H.

    1987-07-01

    Prototype superconducting quadrupoles with a 5 cm aperture and gradient of 16 kG/cm have been built and tested as candidate magnets for the final focus at SLC. The magnets are made from NbTi Tevatron style cable with 10 inner and 14 outer turns per quadrant. Quench performance and multipole data are presented. Design and data for a low current, high gradient quadrupole, similar in cross section but wound with a cable consisting of five insulated conductors are also discussed

  15. B1 gradient coherence selection using a tapered stripline.

    Science.gov (United States)

    van Meerten, S G J; Tijssen, K C H; van Bentum, P J M; Kentgens, A P M

    2018-01-01

    Pulsed-field gradients are common in modern liquid state NMR pulse sequences. They are often used instead of phase cycles for the selection of coherence pathways, thereby decreasing the time required for the NMR experiment. Soft off-resonance pulses with a B 1 gradient result in a spatial encoding similar to that created by pulsed-field (B 0 ) gradients. In this manuscript we show that pulse sequences with pulsed-field gradients can easily be converted to one which uses off-resonance B 1 field gradient (OFFBEAT) pulses. The advantage of B 1 gradient pulses for coherence selection is that the chemical shift evolution during the pulses is (partially) suppressed. Therefore no refocusing echos are required to correct for evolution during the gradient pulses. A tapered stripline is shown to be a convenient tool for creating a well-defined gradient in the B 1 field strength. B 1 gradient coherence selection using a tapered stripline is a simple and cheap alternative to B 0 pulsed-field gradients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Flexoelectricity: strain gradient effects in ferroelectrics

    Energy Technology Data Exchange (ETDEWEB)

    Ma Wenhui [Department of Physics, Shantou Unversity, Shantou, Guangdong 515063 (China)

    2007-12-15

    Mechanical strain gradient induced polarization effect or flexoelectricity in perovskite-type ferroelectric and relaxor ferroelectric ceramics was investigated. The flexoelectric coefficients measured at room temperature ranged from about 1 {mu} C m{sup -1} for lead zirconate titanate to 100 {mu} C m{sup -1} for barium strontium titanate. Flexoelectric effects were discovered to be sensitive to chemical makeup, phase symmetry, and domain structures. Based on phenomenological discussion and experimental data on flexoelectricity, the present study proposed that mechanical strain gradient field could influence polarization responses in a way analogous to electric field. Flexoelectric coefficients were found to be nonlinearly enhanced by dielectric permittivity and strain gradient. Interfacial mismatch in epitaxial thin films can give rise to high strain gradients, enabling flexoelectric effects to make a significant impact in properly engineered ferroelectric heterostructure systems.

  17. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments.

    Science.gov (United States)

    Tyler, Madelaine K

    2016-01-08

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.

  18. Sildenafil does not influence hepatic venous pressure gradient in patients with cirrhosis

    DEFF Research Database (Denmark)

    Clemmesen, Jens-Otto; Giraldi, Annamaria; Ott, Peter

    2008-01-01

    AIM: To investigate if sildenafil increases splanchnic blood flow and changes the hepatic venous pressure gradient (HVPG) in patients with cirrhosis. Phosphodiesterase type-5 inhibitors are valuable in the treatment of erectile dysfunction and pulmonary hypertension in patients with end-stage liv...... type-5 inhibitor sildenafil, the present study could not demonstrate any clinical relevant influence on splanichnic blood flow, oxygen consumption or the HVPG....

  19. Global correlation imaging of magnetic total field gradients

    International Nuclear Information System (INIS)

    Guo, Lianghui; Meng, Xiaohong; Shi, Lei

    2012-01-01

    Firstly we introduce the correlation imaging approach for the x-, y- and z-gradients of a magnetic total field anomaly for deriving the distribution of equivalent magnetic sources of the subsurface. In this approach, the subsurface space is divided into a regular grid, and then a correlation coefficient function is computed at each grid node, based on the cross-correlation between the x-gradient (or y-gradient or z-gradient) of the observed magnetic total field anomaly and the x-gradient (or y-gradient or z-gradient) of the theoretical magnetic total field anomaly due to a magnetic dipole. The resultant correlation coefficient is used to describe the probability of a magnetic dipole occurring at the node. We then define a global correlation coefficient function for comprehensively delineating the probability of an occurrence of a magnetic dipole, which takes, at each node, the maximum positive value of the corresponding correlation coefficient function of the three gradients. We finally test the approach both on synthetic data and real data from a metallic deposit area in the middle-lower reaches of the Yangtze River, China. (paper)

  20. Photon and proton therapy planning comparison for malignant glioma based on CT, FDG-PET, DTI-MRI and fiber tracking

    Energy Technology Data Exchange (ETDEWEB)

    Munck af Rosenschoeld, Per; Engelholm, Silke; Ohlhues, Lars; Vogelius, Ivan; Engelholm, Svend Aage (Radiation Medicine Research Center, Dept. of Radiation Oncology, Rigshospitalet, Copenhagen (Denmark)), e-mail: per.munck@rh.regionh.dk; Law, Ian (Dept. of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark))

    2011-08-15

    Purpose. The purpose of this study was to compare treatment plans generated using fixed beam Intensity Modulated photon Radiation Therapy (IMRT), inversely optimized arc therapy (RapidArc(R), RA) with spot-scanned Intensity Modulated Proton Therapy (IMPT) for high-grade glioma patients. Plans were compared with respect to target coverage and sparing of organs at risk (OARs), with special attention to the possibility of hippocampus sparing. Method. Fifteen consecutive patients diagnosed with grade III and IV glioma were selected for this study. The target and OARs were delineated based on computed tomography (CT), FDG-positron emission tomography (PET) and T1-, T2-weighted, and Diffusion Tensor Imaging (DTI) magnetic resonance imaging (MRI) and fiber-tracking. In this study, a 6 MV photon beam on a linear accelerator with a multileaf collimator (MLC) with 2.5 mm leaves and a spot-scanning proton therapy machine were used. Two RA fields, using both a coplanar (clinical standard) and a non-coplanar, setup was compared to the IMRT and IMPT techniques. Three and three to four non-coplanar fields where used in the spot-scanned IMPT and IMRT plans, respectively. The same set of planning dose-volume optimizer objective values were used for the four techniques. The highest planning priority was given to the brainstem (maximum 54 Gy) followed by the PTV (prescription 60 Gy); the hippocampi, eyes, inner ears, brain and chiasm were given lower priority. Doses were recorded for the plans to targets and OARs and compared to our clinical standard technique using the Wilcoxon signed rank test. Result. The PTV coverage was significantly more conform for IMPT than the coplanar RA technique, while RA plans tended to be more conform than the IMRT plans, as measured by the standard deviation of the PTV dose. In the cases where the tumor was confined in one cerebral hemisphere (eight patients), the non-coplanar RA and IMPT techniques yielded borderline significantly lower doses to the

  1. Universal field matching in craniospinal irradiation by a background-dose gradient-optimized method.

    Science.gov (United States)

    Traneus, Erik; Bizzocchi, Nicola; Fellin, Francesco; Rombi, Barbara; Farace, Paolo

    2018-01-01

    The gradient-optimized methods are overcoming the traditional feathering methods to plan field junctions in craniospinal irradiation. In this note, a new gradient-optimized technique, based on the use of a background dose, is described. Treatment planning was performed by RayStation (RaySearch Laboratories, Stockholm, Sweden) on the CT scans of a pediatric patient. Both proton (by pencil beam scanning) and photon (by volumetric modulated arc therapy) treatments were planned with three isocenters. An 'in silico' ideal background dose was created first to cover the upper-spinal target and to produce a perfect dose gradient along the upper and lower junction regions. Using it as background, the cranial and the lower-spinal beams were planned by inverse optimization to obtain dose coverage of their relevant targets and of the junction volumes. Finally, the upper-spinal beam was inversely planned after removal of the background dose and with the previously optimized beams switched on. In both proton and photon plans, the optimized cranial and the lower-spinal beams produced a perfect linear gradient in the junction regions, complementary to that produced by the optimized upper-spinal beam. The final dose distributions showed a homogeneous coverage of the targets. Our simple technique allowed to obtain high-quality gradients in the junction region. Such technique universally works for photons as well as protons and could be applicable to the TPSs that allow to manage a background dose. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  2. Is the temperature gradient or the derivative of the density gradient responsible for drift solitons?

    International Nuclear Information System (INIS)

    Salat, A.

    1990-01-01

    In conventional drift wave theory the density gradient κ n =d lnn/dχ determines the linear phase velocity, and the (electron) temperature gradient κ T =d lnT/dχ gives rise to a nonlinear term which leads to the existence of soliton-type solutions and solitary waves. LAKHIN, MIKHAILOVSKI and ONISHCHENKO, Phys. Lett. A 119, 348 (1987) and Plasma Phys. and Contr. Fus. 30, 457 (1988), recently claimed that it is not κ T but essentially the derivative of the density gradient, dκ n /dχ, that is relevant. This claim is refuted by means of an expansion scheme in ε=eΦ/T≤1, where Φ is the drift wave potential. (orig.)

  3. Dual fuel gradients in uranium silicide plates

    Energy Technology Data Exchange (ETDEWEB)

    Pace, B.W. [Babock and Wilcox, Lynchburg, VA (United States)

    1997-08-01

    Babcock & Wilcox has been able to achieve dual gradient plates with good repeatability in small lots of U{sub 3}Si{sub 2} plates. Improvements in homogeneity and other processing parameters and techniques have allowed the development of contoured fuel within the cladding. The most difficult obstacles to overcome have been the ability to evaluate the bidirectional fuel loadings in comparison to the perfect loading model and the different methods of instilling the gradients in the early compact stage. The overriding conclusion is that to control the contour of the fuel, a known relationship between the compact, the frames and final core gradient must exist. Therefore, further development in the creation and control of dual gradients in fuel plates will involve arriving at a plausible gradient requirement and building the correct model between the compact configuration and the final contoured loading requirements.

  4. Modified conjugate gradient method for diagonalizing large matrices.

    Science.gov (United States)

    Jie, Quanlin; Liu, Dunhuan

    2003-11-01

    We present an iterative method to diagonalize large matrices. The basic idea is the same as the conjugate gradient (CG) method, i.e, minimizing the Rayleigh quotient via its gradient and avoiding reintroducing errors to the directions of previous gradients. Each iteration step is to find lowest eigenvector of the matrix in a subspace spanned by the current trial vector and the corresponding gradient of the Rayleigh quotient, as well as some previous trial vectors. The gradient, together with the previous trial vectors, play a similar role as the conjugate gradient of the original CG algorithm. Our numeric tests indicate that this method converges significantly faster than the original CG method. And the computational cost of one iteration step is about the same as the original CG method. It is suitable for first principle calculations.

  5. Stability of gradient semigroups under perturbations

    Science.gov (United States)

    Aragão-Costa, E. R.; Caraballo, T.; Carvalho, A. N.; Langa, J. A.

    2011-07-01

    In this paper we prove that gradient-like semigroups (in the sense of Carvalho and Langa (2009 J. Diff. Eqns 246 2646-68)) are gradient semigroups (possess a Lyapunov function). This is primarily done to provide conditions under which gradient semigroups, in a general metric space, are stable under perturbation exploiting the known fact (see Carvalho and Langa (2009 J. Diff. Eqns 246 2646-68)) that gradient-like semigroups are stable under perturbation. The results presented here were motivated by the work carried out in Conley (1978 Isolated Invariant Sets and the Morse Index (CBMS Regional Conference Series in Mathematics vol 38) (RI: American Mathematical Society Providence)) for groups in compact metric spaces (see also Rybakowski (1987 The Homotopy Index and Partial Differential Equations (Universitext) (Berlin: Springer)) for the Morse decomposition of an invariant set for a semigroup on a compact metric space).

  6. Usefulness of diffusion tensor imaging in amyotrophic lateral sclerosis: potential biomarker and association with the cognitive profile

    Directory of Open Access Journals (Sweden)

    Marcelo Chaves

    Full Text Available ABSTRACT The objective of this preliminary study was to correlate diffusion tensor imaging (DTI alterations with the cognitive profile of patients with amyotrophic lateral sclerosis (ALS. Methods This was a case-control study conducted from December 1, 2012 to December 1, 2014. Clinical and demographic data were recorded. A neuropsychological test battery adapted to ALS patients was used. An MRI with DTI was performed in all patients and fractional anisotropy (FA was analyzed in the white matter using the tract based spatial statistics program. Results Twenty-four patients with ALS (15 females, mean age 66.9 + -2.3 and 13 healthy controls (four females, average age 66.9 + - 2 were included. The DTI showed white matter damage in ALS patients vs. healthy controls (p < 0.001. Discussion In our preliminary study the alterations of white matter in DTI were significantly associated with cognitive impairment in patients with ALS.

  7. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging

    DEFF Research Database (Denmark)

    Lasic, Samo; Lundell, Henrik; Topgaard, Daniel

    2017-01-01

    low-pass diffusion filtering during the LS interval, which is more pronounced at lower exchange rates. For a total exchange rate constant larger than 1 s-1, the AXR bias is expected to be negligible when slices thicker than 2.5mm are used. Conclusion: In correlation experiments like FEXI, relying...... on LS with variable duration, imaging gradients may cause disrupting effects that cannot be easily mitigated and should be carefully considered for unbiased results. In typical clinical applications of FEXI, the imaging gradients are expected to cause a negligible AXR bias. However, the AXR bias may...

  8. What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Nelson, Arden D.; Choi, Walter; Arai, Yoshio; Faulhaber, Peter F.; Kang, Patrick; Almeida, Fabio D.; Xiao, Ying; Ohri, Nitin; Brockway, Kristin D.; Piper, Jonathan W.; Nelson, Aaron S.

    2012-01-01

    Purpose: To evaluate the accuracy and consistency of a gradient-based positron emission tomography (PET) segmentation method, GRADIENT, compared with manual (MANUAL) and constant threshold (THRESHOLD) methods. Methods and Materials: Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10–37 mm in diameter and were acquired at five institutions emulating clinical conditions. One institution also acquired a sphere phantom with multiple source-to-background ratios of 2:1, 5:1, 10:1, 20:1, and 70:1. One observer segmented (contoured) each sphere with GRADIENT and THRESHOLD from 25% to 50% at 5% increments. Subsequently, seven physicians segmented 31 lesions (7–264 mL) from 25 digital thorax phantoms using GRADIENT, THRESHOLD, and MANUAL. Results: For spheres 20 mm (p < 0.065) and <20 mm (p < 0.015). For digital thorax phantoms, GRADIENT was the most accurate (p < 0.01), with a mean absolute % error in volume of 10.99% (11.9% SD), followed by 25% THRESHOLD at 17.5% (29.4% SD), and MANUAL at 19.5% (17.2% SD). GRADIENT had the least systematic bias, with a mean % error in volume of –0.05% (16.2% SD) compared with 25% THRESHOLD at –2.1% (34.2% SD) and MANUAL at –16.3% (20.2% SD; p value <0.01). Interobserver variability was reduced using GRADIENT compared with both 25% THRESHOLD and MANUAL (p value <0.01, Levene’s test). Conclusion: GRADIENT was the most accurate and consistent technique for target volume contouring. GRADIENT was also the most robust for varying imaging conditions. GRADIENT has the potential to play an important role for tumor delineation in radiation therapy planning and response assessment.

  9. Fundamental limits to position determination by concentration gradients.

    Directory of Open Access Journals (Sweden)

    Filipe Tostevin

    2007-04-01

    Full Text Available Position determination in biological systems is often achieved through protein concentration gradients. Measuring the local concentration of such a protein with a spatially varying distribution allows the measurement of position within the system. For these systems to work effectively, position determination must be robust to noise. Here, we calculate fundamental limits to the precision of position determination by concentration gradients due to unavoidable biochemical noise perturbing the gradients. We focus on gradient proteins with first-order reaction kinetics. Systems of this type have been experimentally characterised in both developmental and cell biology settings. For a single gradient we show that, through time-averaging, great precision potentially can be achieved even with very low protein copy numbers. As a second example, we investigate the ability of a system with oppositely directed gradients to find its centre. With this mechanism, positional precision close to the centre improves more slowly with increasing averaging time, and so longer averaging times or higher copy numbers are required for high precision. For both single and double gradients, we demonstrate the existence of optimal length scales for the gradients for which precision is maximized, as well as analyze how precision depends on the size of the concentration-measuring apparatus. These results provide fundamental constraints on the positional precision supplied by concentration gradients in various contexts, including both in developmental biology and also within a single cell.

  10. Pressure gradients fail to predict diffusio-osmosis

    Science.gov (United States)

    Liu, Yawei; Ganti, Raman; Frenkel, Daan

    2018-05-01

    We present numerical simulations of diffusio-osmotic flow, i.e. the fluid flow generated by a concentration gradient along a solid-fluid interface. In our study, we compare a number of distinct approaches that have been proposed for computing such flows and compare them with a reference calculation based on direct, non-equilibrium molecular dynamics simulations. As alternatives, we consider schemes that compute diffusio-osmotic flow from the gradient of the chemical potentials of the constituent species and from the gradient of the component of the pressure tensor parallel to the interface. We find that the approach based on treating chemical potential gradients as external forces acting on various species agrees with the direct simulations, thereby supporting the approach of Marbach et al (2017 J. Chem. Phys. 146 194701). In contrast, an approach based on computing the gradients of the microscopic pressure tensor does not reproduce the direct non-equilibrium results.

  11. What Is the Best Way to Contour Lung Tumors on PET Scans? Multiobserver Validation of a Gradient-Based Method Using a NSCLC Digital PET Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Werner-Wasik, Maria, E-mail: Maria.Werner-wasik@jeffersonhospital.org [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Nelson, Arden D. [MIM Software Inc., Cleveland, OH (United States); Choi, Walter [Department of Radiation Oncology, UPMC Health Systems, Pittsburgh, PA (United States); Arai, Yoshio [Department of Radiation Oncology, Beth Israel Medical Center, New York, NY (Israel); Faulhaber, Peter F. [University Hospitals Case Medical Center, Cleveland, OH (United States); Kang, Patrick [Department of Radiology, Beth Israel Medical Center, New York, NY (Israel); Almeida, Fabio D. [Division of Nuclear Medicine, University of Arizona Health Sciences Center, Tucson, AZ (United States); Xiao, Ying; Ohri, Nitin [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Brockway, Kristin D.; Piper, Jonathan W.; Nelson, Aaron S. [MIM Software Inc., Cleveland, OH (United States)

    2012-03-01

    Purpose: To evaluate the accuracy and consistency of a gradient-based positron emission tomography (PET) segmentation method, GRADIENT, compared with manual (MANUAL) and constant threshold (THRESHOLD) methods. Methods and Materials: Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10-37 mm in diameter and were acquired at five institutions emulating clinical conditions. One institution also acquired a sphere phantom with multiple source-to-background ratios of 2:1, 5:1, 10:1, 20:1, and 70:1. One observer segmented (contoured) each sphere with GRADIENT and THRESHOLD from 25% to 50% at 5% increments. Subsequently, seven physicians segmented 31 lesions (7-264 mL) from 25 digital thorax phantoms using GRADIENT, THRESHOLD, and MANUAL. Results: For spheres <20 mm in diameter, GRADIENT was the most accurate with a mean absolute % error in diameter of 8.15% (10.2% SD) compared with 49.2% (51.1% SD) for 45% THRESHOLD (p < 0.005). For larger spheres, the methods were statistically equivalent. For varying source-to-background ratios, GRADIENT was the most accurate for spheres >20 mm (p < 0.065) and <20 mm (p < 0.015). For digital thorax phantoms, GRADIENT was the most accurate (p < 0.01), with a mean absolute % error in volume of 10.99% (11.9% SD), followed by 25% THRESHOLD at 17.5% (29.4% SD), and MANUAL at 19.5% (17.2% SD). GRADIENT had the least systematic bias, with a mean % error in volume of -0.05% (16.2% SD) compared with 25% THRESHOLD at -2.1% (34.2% SD) and MANUAL at -16.3% (20.2% SD; p value <0.01). Interobserver variability was reduced using GRADIENT compared with both 25% THRESHOLD and MANUAL (p value <0.01, Levene's test). Conclusion: GRADIENT was the most accurate and consistent technique for target volume contouring. GRADIENT was also the most robust for varying imaging conditions. GRADIENT has the potential to play an important role for tumor delineation in

  12. A method for easily customizable gradient gel electrophoresis.

    Science.gov (United States)

    Miller, Andrew J; Roman, Brandon; Norstrom, Eric

    2016-09-15

    Gradient polyacrylamide gel electrophoresis is a powerful tool for the resolution of polypeptides by relative mobility. Here, we present a simplified method for generating polyacrylamide gradient gels for routine analysis without the need for specialized mixing equipment. The method allows for easily customizable gradients which can be optimized for specific polypeptide resolution requirements. Moreover, the method eliminates the possibility of buffer cross contamination in mixing equipment, and the time and resources saved with this method in place of traditional gradient mixing, or the purchase of pre-cast gels, are noteworthy given the frequency with which many labs use gradient gel SDS-PAGE. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Gradient-type methods in inverse parabolic problems

    International Nuclear Information System (INIS)

    Kabanikhin, Sergey; Penenko, Aleksey

    2008-01-01

    This article is devoted to gradient-based methods for inverse parabolic problems. In the first part, we present a priori convergence theorems based on the conditional stability estimates for linear inverse problems. These theorems are applied to backwards parabolic problem and sideways parabolic problem. The convergence conditions obtained coincide with sourcewise representability in the self-adjoint backwards parabolic case but they differ in the sideways case. In the second part, a variational approach is formulated for a coefficient identification problem. Using adjoint equations, a formal gradient of an objective functional is constructed. A numerical test illustrates the performance of conjugate gradient algorithm with the formal gradient.

  14. On lower order strain gradient plasticity theories

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Hutchinson, J. W.

    2003-01-01

    By way of numerical examples, this paper explores the nature of solutions to a class of strain gradient plasticity theories that employ conventional stresses, equilibrium equations and boundary conditions. Strain gradients come into play in these modified conventional theories only to alter...... the tangent moduli governing increments of stress and strain. It is shown that the modification is far from benign from a mathematical standpoint, changing the qualitative character of solutions and leading to a new type of localization that is at odds with what is expected from a strain gradient theory....... The findings raise questions about the physical acceptability of this class of strain gradient theories....

  15. Stability of gradient semigroups under perturbations

    International Nuclear Information System (INIS)

    Aragão-Costa, E R; Carvalho, A N; Caraballo, T; Langa, J A

    2011-01-01

    In this paper we prove that gradient-like semigroups (in the sense of Carvalho and Langa (2009 J. Diff. Eqns 246 2646–68)) are gradient semigroups (possess a Lyapunov function). This is primarily done to provide conditions under which gradient semigroups, in a general metric space, are stable under perturbation exploiting the known fact (see Carvalho and Langa (2009 J. Diff. Eqns 246 2646–68)) that gradient-like semigroups are stable under perturbation. The results presented here were motivated by the work carried out in Conley (1978 Isolated Invariant Sets and the Morse Index (CBMS Regional Conference Series in Mathematics vol 38) (RI: American Mathematical Society Providence)) for groups in compact metric spaces (see also Rybakowski (1987 The Homotopy Index and Partial Differential Equations (Universitext) (Berlin: Springer)) for the Morse decomposition of an invariant set for a semigroup on a compact metric space)

  16. Sildenafil does not influence hepatic venous pressure gradient in patients with cirrhosis

    DEFF Research Database (Denmark)

    Clemmesen, J.O.; Giraldi, A.; Ott, P.

    2008-01-01

    AIM: To investigate if sildenafil increases splanchnic blood flow and changes the hepatic venous pressure gradient (HVPG) in patients with cirrhosis. Phosphodiesterase type-5 inhibitors are valuable in the treatment of erectile dysfunction and pulmonary hypertension in patients with end-stage liv...... type-5 inhibitor sildenafil, the present study could not demonstrate any clinical relevant influence on splanichnic blood flow, oxygen consumption or the HVPG Udgivelsesdato: 2008/10/28...

  17. A substrate independent approach for generation of surface gradients

    Energy Technology Data Exchange (ETDEWEB)

    Goreham, Renee V. [Mawson Institute, University of South Australia, Mawson Lakes 5095 (Australia); Mierczynska, Agnieszka; Pierce, Madelene [Ian Wark Research Institute, University of South Australia, Mawson Lakes 5095 (Australia); Short, Robert D.; Taheri, Shima; Bachhuka, Akash; Cavallaro, Alex; Smith, Louise E. [Mawson Institute, University of South Australia, Mawson Lakes 5095 (Australia); Vasilev, Krasimir, E-mail: krasimir.vasilev@unisa.edu.au [Mawson Institute, University of South Australia, Mawson Lakes 5095 (Australia)

    2013-01-01

    Recently, surface gradients have attracted significant interest for various research and technological applications. In this paper, we report a facile and versatile method for generating surface gradients of immobilized nanoparticles, nanotopography and ligands that is independent from the substrate material. The method consists of first depositing a functional polymer layer on a substrate and subsequent time controlled immersion of this functionalized substrate in solution gold nanoparticles (AuNPs), silver nanoparticles (AgNPs) or poly (styrenesulfonate) (PSS). Chemical characterization by X-ray Photoelectron Spectroscopy (XPS) and morphological analysis by Atomic Force Microscopy (AFM) show that the density of nanoparticles and the concentration of PSS across the surface increases in a gradient manner. As expected, time of immersion determines the concentration of surface bound species. We also demonstrate the generation of surface gradients of pure nanotopography. This is achieved by depositing a 5 nm thick plasma polymer layer on top of the number density gradient of nanoparticles to achieve a homogeneous surface chemistry. The surface independent approach for generation of surface gradients presented in this paper may open opportunities for a wider use of surface gradient in research and in various technologies. - Highlights: ► We present a substrate independent approach for generation of surface gradients. ► We demonstrate well-defined density gradients of gold and silver nanoparticles. ► We provide an example of pure surface nanotopography gradients. ► We demonstrate concentration gradients of bound ligands.

  18. A substrate independent approach for generation of surface gradients

    International Nuclear Information System (INIS)

    Goreham, Renee V.; Mierczynska, Agnieszka; Pierce, Madelene; Short, Robert D.; Taheri, Shima; Bachhuka, Akash; Cavallaro, Alex; Smith, Louise E.; Vasilev, Krasimir

    2013-01-01

    Recently, surface gradients have attracted significant interest for various research and technological applications. In this paper, we report a facile and versatile method for generating surface gradients of immobilized nanoparticles, nanotopography and ligands that is independent from the substrate material. The method consists of first depositing a functional polymer layer on a substrate and subsequent time controlled immersion of this functionalized substrate in solution gold nanoparticles (AuNPs), silver nanoparticles (AgNPs) or poly (styrenesulfonate) (PSS). Chemical characterization by X-ray Photoelectron Spectroscopy (XPS) and morphological analysis by Atomic Force Microscopy (AFM) show that the density of nanoparticles and the concentration of PSS across the surface increases in a gradient manner. As expected, time of immersion determines the concentration of surface bound species. We also demonstrate the generation of surface gradients of pure nanotopography. This is achieved by depositing a 5 nm thick plasma polymer layer on top of the number density gradient of nanoparticles to achieve a homogeneous surface chemistry. The surface independent approach for generation of surface gradients presented in this paper may open opportunities for a wider use of surface gradient in research and in various technologies. - Highlights: ► We present a substrate independent approach for generation of surface gradients. ► We demonstrate well-defined density gradients of gold and silver nanoparticles. ► We provide an example of pure surface nanotopography gradients. ► We demonstrate concentration gradients of bound ligands

  19. Refined discrete and empirical horizontal gradients in VLBI analysis

    Science.gov (United States)

    Landskron, Daniel; Böhm, Johannes

    2018-02-01

    Missing or incorrect consideration of azimuthal asymmetry of troposphere delays is a considerable error source in space geodetic techniques such as Global Navigation Satellite Systems (GNSS) or Very Long Baseline Interferometry (VLBI). So-called horizontal troposphere gradients are generally utilized for modeling such azimuthal variations and are particularly required for observations at low elevation angles. Apart from estimating the gradients within the data analysis, which has become common practice in space geodetic techniques, there is also the possibility to determine the gradients beforehand from different data sources than the actual observations. Using ray-tracing through Numerical Weather Models (NWMs), we determined discrete gradient values referred to as GRAD for VLBI observations, based on the standard gradient model by Chen and Herring (J Geophys Res 102(B9):20489-20502, 1997. https://doi.org/10.1029/97JB01739) and also for new, higher-order gradient models. These gradients are produced on the same data basis as the Vienna Mapping Functions 3 (VMF3) (Landskron and Böhm in J Geod, 2017.https://doi.org/10.1007/s00190-017-1066-2), so they can also be regarded as the VMF3 gradients as they are fully consistent with each other. From VLBI analyses of the Vienna VLBI and Satellite Software (VieVS), it becomes evident that baseline length repeatabilities (BLRs) are improved on average by 5% when using a priori gradients GRAD instead of estimating the gradients. The reason for this improvement is that the gradient estimation yields poor results for VLBI sessions with a small number of observations, while the GRAD a priori gradients are unaffected from this. We also developed a new empirical gradient model applicable for any time and location on Earth, which is included in the Global Pressure and Temperature 3 (GPT3) model. Although being able to describe only the systematic component of azimuthal asymmetry and no short-term variations at all, even these

  20. Continuous spray forming of functionally gradient materials

    International Nuclear Information System (INIS)

    McKechnie, T.N.; Richardson, E.H.

    1995-01-01

    Researchers at Plasma Processes Inc. have produced a Functional Gradient Material (FGM) through advanced vacuum plasma spray processing for high heat flux applications. Outlined in this paper are the manufacturing methods used to develop a four component functional gradient material of copper, tungsten, boron, and boron nitride. The FGM was formed with continuous gradients and integral cooling channels eliminating bondlines and providing direct heat transfer from the high temperature exposed surface to a cooling medium. Metallurgical and x-ray diffraction analyses of the materials formed through innovative VPS (vacuum plasma spray) processing are also presented. Applications for this functional gradient structural material range from fusion reactor plasma facing components to missile nose cones to boilers

  1. Calibration of a rotating accelerometer gravity gradiometer using centrifugal gradients

    Science.gov (United States)

    Yu, Mingbiao; Cai, Tijing

    2018-05-01

    The purpose of this study is to calibrate scale factors and equivalent zero biases of a rotating accelerometer gravity gradiometer (RAGG). We calibrate scale factors by determining the relationship between the centrifugal gradient excitation and RAGG response. Compared with calibration by changing the gravitational gradient excitation, this method does not need test masses and is easier to implement. The equivalent zero biases are superpositions of self-gradients and the intrinsic zero biases of the RAGG. A self-gradient is the gravitational gradient produced by surrounding masses, and it correlates well with the RAGG attitude angle. We propose a self-gradient model that includes self-gradients and the intrinsic zero biases of the RAGG. The self-gradient model is a function of the RAGG attitude, and it includes parameters related to surrounding masses. The calibration of equivalent zero biases determines the parameters of the self-gradient model. We provide detailed procedures and mathematical formulations for calibrating scale factors and parameters in the self-gradient model. A RAGG physical simulation system substitutes for the actual RAGG in the calibration and validation experiments. Four point masses simulate four types of surrounding masses producing self-gradients. Validation experiments show that the self-gradients predicted by the self-gradient model are consistent with those from the outputs of the RAGG physical simulation system, suggesting that the presented calibration method is valid.

  2. Ultra-high gradient compact accelerator developments

    NARCIS (Netherlands)

    Brussaard, G.J.H.; Wiel, van der M.J.

    2004-01-01

    Continued development of relatively compact, although not quite 'table-top', lasers with peak powers in the range up to 100 TW has enabled laser-plasma-based acceleration experiments with amazing gradients of up to 1 TV/m. In order to usefully apply such gradients to 'controlled' acceleration,

  3. 40 CFR 230.25 - Salinity gradients.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Salinity gradients. 230.25 Section 230.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING SECTION 404(b... Physical and Chemical Characteristics of the Aquatic Ecosystem § 230.25 Salinity gradients. (a) Salinity...

  4. DWI-Based Neural Fingerprinting Technology: A Preliminary Study on Stroke Analysis

    Directory of Open Access Journals (Sweden)

    Chenfei Ye

    2014-01-01

    Full Text Available Stroke is a common neural disorder in neurology clinics. Magnetic resonance imaging (MRI has become an important tool to assess the neural physiological changes under stroke, such as diffusion weighted imaging (DWI and diffusion tensor imaging (DTI. Quantitative analysis of MRI images would help medical doctors to localize the stroke area in the diagnosis in terms of structural information and physiological characterization. However, current quantitative approaches can only provide localization of the disorder rather than measure physiological variation of subtypes of ischemic stroke. In the current study, we hypothesize that each kind of neural disorder would have its unique physiological characteristics, which could be reflected by DWI images on different gradients. Based on this hypothesis, a DWI-based neural fingerprinting technology was proposed to classify subtypes of ischemic stroke. The neural fingerprint was constructed by the signal intensity of the region of interest (ROI on the DWI images under different gradients. The fingerprint derived from the manually drawn ROI could classify the subtypes with accuracy 100%. However, the classification accuracy was worse when using semiautomatic and automatic method in ROI segmentation. The preliminary results showed promising potential of DWI-based neural fingerprinting technology in stroke subtype classification. Further studies will be carried out for enhancing the fingerprinting accuracy and its application in other clinical practices.

  5. Morphogengineering roots: comparing mechanisms of morphogen gradient formation

    Science.gov (United States)

    2012-01-01

    Background In developmental biology, there has been a recent focus on the robustness of morphogen gradients as possible providers of positional information. It was shown that functional morphogen gradients present strong biophysical constraints and lack of robustness to noise. Here we explore how the details of the mechanism which underlies the generation of a morphogen gradient can influence those properties. Results We contrast three gradient-generating mechanisms, (i) a source-decay mechanism; and (ii) a unidirectional transport mechanism; and (iii) a so-called reflux-loop mechanism. Focusing on the dynamics of the phytohormone auxin in the root, we show that only the reflux-loop mechanism can generate a gradient that would be adequate to supply functional positional information for the Arabidopsis root, for biophysically reasonable kinetic parameters. Conclusions We argue that traits that differ in spatial and temporal time-scales can impose complex selective pressures on the mechanism of morphogen gradient formation used for the development of the particular organism. PMID:22583698

  6. Techniques and Applications of in vivo Diffusion Imaging of Articular Cartilage

    Science.gov (United States)

    Raya, José G.

    2014-01-01

    Early in the process of osteoarthritis (OA) the composition (water, proteoglycan [PG], and collagen) and structure of articular cartilage is altered leading to changes in its mechanical properties. A technique that can assess the composition and structure of the cartilage in vivo can provide insight in the mechanical integrity of articular cartilage and become a powerful tool for the early diagnosis of OA. Diffusion tensor imaging (DTI) has been proposed as a biomarker for cartilage composition and structure. DTI is sensitive to the PG content through the mean diffusivity (MD) and to the collagen architecture through the fractional anisotropy (FA). However, the acquisition of DTI of articular cartilage in vivo is challenging due to the short T2 of articular cartilage (~40 ms at 3 T) and the high resolution needed (0.5–0.7 mm in plane) to depict the cartilage anatomy. We describe the pulse sequences used for in vivo DTI of articular cartilage and discus general strategies for protocol optimization. We provide a comprehensive review of measurements of DTI of articular cartilage from ex vivo validation experiments to its recent clinical applications. PMID:25865215

  7. Directional phytoscreening: contaminant gradients in trees for plume delineation.

    Science.gov (United States)

    Limmer, Matt A; Shetty, Mikhil K; Markus, Samantha; Kroeker, Ryan; Parker, Beth L; Martinez, Camilo; Burken, Joel G

    2013-08-20

    Tree sampling methods have been used in phytoscreening applications to delineate contaminated soil and groundwater, augmenting traditional investigative methods that are time-consuming, resource-intensive, invasive, and costly. In the past decade, contaminant concentrations in tree tissues have been shown to reflect the extent and intensity of subsurface contamination. This paper investigates a new phytoscreening tool: directional tree coring, a concept originating from field data that indicated azimuthal concentrations in tree trunks reflected the concentration gradients in the groundwater around the tree. To experimentally test this hypothesis, large diameter trees were subjected to subsurface contaminant concentration gradients in a greenhouse study. These trees were then analyzed for azimuthal concentration gradients in aboveground tree tissues, revealing contaminant centroids located on the side of the tree nearest the most contaminated groundwater. Tree coring at three field sites revealed sufficiently steep contaminant gradients in trees reflected nearby groundwater contaminant gradients. In practice, trees possessing steep contaminant gradients are indicators of steep subsurface contaminant gradients, providing compass-like information about the contaminant gradient, pointing investigators toward higher concentration regions of the plume.

  8. Hydraulic gradients in rock aquifers

    International Nuclear Information System (INIS)

    Dahlblom, P.

    1992-05-01

    This report deals with fractured rock as a host for deposits of hazardous waste. In this context the rock, with its fractures containing moving groundwater, is called the geological barrier. The desired properties of the geological barrier are low permeability to water, low hydraulic gradients and ability to retain matter dissolved in the water. The hydraulic gradient together with the permeability and the porosity determines the migration velocity. Mathematical modelling of the migration involves calculation of the water flow and the hydrodynamic dispersion of the contaminant. The porous medium approach can be used to calculate mean flow velocities and hydrodynamic dispersion of a large number of fractures are connected, which means that a large volume have to be considered. It is assumed that the porous medium approach can be applied, and a number of idealized examples are shown. It is assumed that the groundwater table is replenished by percolation at a constant rate. One-dimensional analytical calculations show that zero hydraulic gradients may exist at relatively large distance from the coast. Two-dimensional numerical calculations show that it may be possible to find areas with low hydraulic gradients and flow velocities within blocks surrounded by areas with high hydraulic conductivity. (au)

  9. Preconditioning the modified conjugate gradient method ...

    African Journals Online (AJOL)

    In this paper, the convergence analysis of the conventional conjugate Gradient method was reviewed. And the convergence analysis of the modified conjugate Gradient method was analysed with our extension on preconditioning the algorithm. Convergence of the algorithm is a function of the condition number of M-1A.

  10. Unimodal and crossmodal gradients of spatial attention

    DEFF Research Database (Denmark)

    Föcker, J.; Hötting, K.; Gondan, Matthias

    2010-01-01

    Behavioral and event-related potential (ERP) studies have shown that spatial attention is gradually distributed around the center of the attentional focus. The present study compared uni- and crossmodal gradients of spatial attention to investigate whether the orienting of auditory and visual...... spatial attention is based on modality specific or supramodal representations of space. Auditory and visual stimuli were presented from five speaker locations positioned in the right hemifield. Participants had to attend to the innermost or outmost right position in order to detect either visual...... or auditory deviant stimuli. Detection rates and event-related potentials (ERPs) indicated that spatial attention is distributed as a gradient. Unimodal spatial ERP gradients correlated with the spatial resolution of the modality. Crossmodal spatial gradients were always broader than the corresponding...

  11. Motor function outcomes of pediatric patients with hemiplegic cerebral palsy after rehabilitation treatment: a diffusion tensor imaging study

    Directory of Open Access Journals (Sweden)

    Jin Hyun Kim

    2015-01-01

    Full Text Available Previous diffusion tensor imaging (DTI studies regarding pediatric patients with motor dysfunction have confirmed the correlation between DTI parameters of the injured corticospinal tract and the severity of motor dysfunction. There is also evidence that DTI parameters can help predict the prognosis of motor function of patients with cerebral palsy. But few studies are reported on the DTI parameters that can reflect the motor function outcomes of pediatric patients with hemiplegic cerebral palsy after rehabilitation treatment. In the present study, 36 pediatric patients with hemiplegic cerebral palsy were included. Before and after rehabilitation treatment, DTI was used to measure the fiber number (FN, fractional anisotropy (FA and apparent diffusion coefficient (ADC of bilateral corticospinal tracts. Functional Level of Hemiplegia scale (FxL was used to assess the therapeutic effect of rehabilitative therapy on clinical hemiplegia. Correlation analysis was performed to assess the statistical interrelationship between the change amount of DTI parameters and FxL. DTI findings obtained at the initial and follow-up evaluations demonstrated that more affected corticospinal tract yielded significantly decreased FN and FA values and significantly increased ADC value compared to the less affected corticospinal tract. Correlation analysis results showed that the change amount of FxL was positively correlated to FN and FA values, and the correlation to FN was stronger than the correlation to FA. The results suggest that FN and FA values can be used to evaluate the motor function outcomes of pediatric patients with hemiplegic cerebral palsy after rehabilitation treatment and FN is of more significance for evaluation.

  12. Collisional transport in a plasma with steep gradients

    International Nuclear Information System (INIS)

    Wang, W.; Okamoto, M.; Nakajima, N.; Murakami, S.

    1999-06-01

    The validity is given to the newly proposed two δf method for neoclassical transport calculation, which can be solve the drift kinetic equation considering effects of steep plasma gradients, large radial electric field, finite banana width, and an orbit topology near the axis. The new method is applied to the study of ion transport with steep plasma gradients. It is found that the ion thermal diffusivity decreases as the scale length of density gradient decreases, while the ion particle flux due to ion-ion self collisions increases with increasing gradient. (author)

  13. Clinical efficacy of a combination of Percoll continuous density gradient and swim-up techniques for semen processing in HIV-1 serodiscordant couples

    Directory of Open Access Journals (Sweden)

    Osamu Inoue

    2017-01-01

    Full Text Available To evaluate the clinical efficacy of a procedure comprising a combination of Percoll continuous density gradient and modified swim-up techniques for the removal of human immunodeficiency virus type 1 (HIV-1 from the semen of HIV-1 infected males, a total of 129 couples with an HIV-1 positive male partner and an HIV-1 negative female partner (serodiscordant couples who were treated at Keio University Hospital between January 2002 and April 2012 were examined. A total of 183 ejaculates from 129 HIV-1 infected males were processed. After swim-up, we successfully collected motile sperms at a recovery rate as high as 100.0% in cases of normozoospermia (126/126 ejaculates, oligozoospermia (6/6, and asthenozoospermia (36/36. The recovery rate of oligoasthenozoospermia was 86.7% (13/15. In processed semen only four ejaculates (4/181:2.2% showed viral nucleotide sequences consistent with those in the blood of the infected males. After using these sperms, no horizontal infections of the female patients and no vertical infections of the newborns were observed. Furthermore, no obvious adverse effects were observed in the offspring. This protocol allowed us to collect HIV-1 negative motile sperms at a high rate, even in male factor cases. We concluded that our protocol is clinically effective both for decreasing HIV-1 infections and for yielding a healthy child.

  14. Gradient dissimilation in Mongolian: Implications for diachrony

    DEFF Research Database (Denmark)

    Jatteau, Adèle; Hejná, Michaela

    2018-01-01

    This paper explores the implications of ‘gradient dissimilation’ (Jatteau & Hejná 2016) for the diachronic implementation of dissimilation. Since this sound change is usually considered as typically sporadic, lexically regular cases should result from lexical diffusion. In contrast with this ass......This paper explores the implications of ‘gradient dissimilation’ (Jatteau & Hejná 2016) for the diachronic implementation of dissimilation. Since this sound change is usually considered as typically sporadic, lexically regular cases should result from lexical diffusion. In contrast...... with this assumption, we explore the hypothesis that gradient dissimilation may represent the phonetic precursor of completed, regular dissimilatory processes. Such cases of dissimilation might then be reanalysed as Neogrammarian types of change. To assess this question, we gather and analyse new data from Halh...... Mongolian, a language reported to show gradient dissimilation (Svantesson et al. 2005), and compare it to two completed patterns of dissimilation reconstructed within the Mongolic family: Mongolian Chahar and Monguor. The results suggest that the gradient dissimilation in Halh may represent the phonetic...

  15. Systems biology derived source-sink mechanism of BMP gradient formation.

    Science.gov (United States)

    Zinski, Joseph; Bu, Ye; Wang, Xu; Dou, Wei; Umulis, David; Mullins, Mary C

    2017-08-09

    A morphogen gradient of Bone Morphogenetic Protein (BMP) signaling patterns the dorsoventral embryonic axis of vertebrates and invertebrates. The prevailing view in vertebrates for BMP gradient formation is through a counter-gradient of BMP antagonists, often along with ligand shuttling to generate peak signaling levels. To delineate the mechanism in zebrafish, we precisely quantified the BMP activity gradient in wild-type and mutant embryos and combined these data with a mathematical model-based computational screen to test hypotheses for gradient formation. Our analysis ruled out a BMP shuttling mechanism and a bmp transcriptionally-informed gradient mechanism. Surprisingly, rather than supporting a counter-gradient mechanism, our analyses support a fourth model, a source-sink mechanism, which relies on a restricted BMP antagonist distribution acting as a sink that drives BMP flux dorsally and gradient formation. We measured Bmp2 diffusion and found that it supports the source-sink model, suggesting a new mechanism to shape BMP gradients during development.

  16. Structures and Strength of Gradient Nanostructures

    DEFF Research Database (Denmark)

    Hansen, Niels; Zhang, Xiaodan; Huang, Xiaoxu

    distance from the surface forming a gradient structure. In this study [2], by shot peening of a low carbon steel a gradient structure has been produced extending to about 1 mm below the surface. A number of strengthening mechanisms have been analyzed as a basis for a calculation of the stress and strain...

  17. Combined MR direct thrombus imaging and non-contrast magnetic resonance venography reveal the evolution of deep vein thrombosis: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Mendichovszky, I.A.; Lomas, D.J. [Addenbrooke' s Hospital, Department of Radiology, Cambridge (United Kingdom); University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Priest, A.N.; Bowden, D.J.; Hunter, S.; Joubert, I.; Hilborne, S.; Graves, M.J. [Addenbrooke' s Hospital, Department of Radiology, Cambridge (United Kingdom); Baglin, T. [Addenbrooke' s Hospital, Department of Haematology, Cambridge (United Kingdom)

    2017-06-15

    Lower limb deep venous thrombosis (DVT) is a common condition with high morbidity and mortality. The aim of the study was to investigate the temporal evolution of the acute thrombus by magnetic resonance imaging (MRI) and its relationship to venous recanalization in patients with recurrent DVTs. Thirteen patients with newly diagnosed lower limb DVTs underwent MRI with non-contrast MR venography (NC-MRV) and MR direct thrombus imaging (MR-DTI), an inversion-recovery water-selective fast gradient-echo acquisition. Imaging was performed within 7 days of the acute thrombotic event, then at 3 and 6 months. By 3 months from the thrombotic event a third of the thrombi had resolved and by 6 months about half of the cases had resolved on the basis of vein recanalisation using NC-MRV. On the initial MR-DTI acute thrombus was clearly depicted by hyperintense signal, while the remaining thrombi were predominantly low signal at 3 and 6 months. Some residual thrombi contained small and fragmented persisting hyperintense areas at 3 months, clearing almost completely by 6 months. Our study suggests that synergistic venous assessment with combined NC-MRV and MR-DTI is able to distinguish acute venous thrombosis from the established (old) or evolving DVT detected by ultrasound. (orig.)

  18. Combined MR direct thrombus imaging and non-contrast magnetic resonance venography reveal the evolution of deep vein thrombosis: a feasibility study

    International Nuclear Information System (INIS)

    Mendichovszky, I.A.; Lomas, D.J.; Priest, A.N.; Bowden, D.J.; Hunter, S.; Joubert, I.; Hilborne, S.; Graves, M.J.; Baglin, T.

    2017-01-01

    Lower limb deep venous thrombosis (DVT) is a common condition with high morbidity and mortality. The aim of the study was to investigate the temporal evolution of the acute thrombus by magnetic resonance imaging (MRI) and its relationship to venous recanalization in patients with recurrent DVTs. Thirteen patients with newly diagnosed lower limb DVTs underwent MRI with non-contrast MR venography (NC-MRV) and MR direct thrombus imaging (MR-DTI), an inversion-recovery water-selective fast gradient-echo acquisition. Imaging was performed within 7 days of the acute thrombotic event, then at 3 and 6 months. By 3 months from the thrombotic event a third of the thrombi had resolved and by 6 months about half of the cases had resolved on the basis of vein recanalisation using NC-MRV. On the initial MR-DTI acute thrombus was clearly depicted by hyperintense signal, while the remaining thrombi were predominantly low signal at 3 and 6 months. Some residual thrombi contained small and fragmented persisting hyperintense areas at 3 months, clearing almost completely by 6 months. Our study suggests that synergistic venous assessment with combined NC-MRV and MR-DTI is able to distinguish acute venous thrombosis from the established (old) or evolving DVT detected by ultrasound. (orig.)

  19. Co-occurrence of Local Anisotropic Gradient Orientations (CoLlAGe): A new radiomics descriptor.

    Science.gov (United States)

    Prasanna, Prateek; Tiwari, Pallavi; Madabhushi, Anant

    2016-11-22

    In this paper, we introduce a new radiomic descriptor, Co-occurrence of Local Anisotropic Gradient Orientations (CoLlAGe) for capturing subtle differences between benign and pathologic phenotypes which may be visually indistinguishable on routine anatomic imaging. CoLlAGe seeks to capture and exploit local anisotropic differences in voxel-level gradient orientations to distinguish similar appearing phenotypes. CoLlAGe involves assigning every image voxel an entropy value associated with the co-occurrence matrix of gradient orientations computed around every voxel. The hypothesis behind CoLlAGe is that benign and pathologic phenotypes even though they may appear similar on anatomic imaging, will differ in their local entropy patterns, in turn reflecting subtle local differences in tissue microarchitecture. We demonstrate CoLlAGe's utility in three clinically challenging classification problems: distinguishing (1) radiation necrosis, a benign yet confounding effect of radiation treatment, from recurrent tumors on T1-w MRI in 42 brain tumor patients, (2) different molecular sub-types of breast cancer on DCE-MRI in 65 studies and (3) non-small cell lung cancer (adenocarcinomas) from benign fungal infection (granulomas) on 120 non-contrast CT studies. For each of these classification problems, CoLlAGE in conjunction with a random forest classifier outperformed state of the art radiomic descriptors (Haralick, Gabor, Histogram of Gradient Orientations).

  20. Coreless Concept for High Gradient Induction Cell

    International Nuclear Information System (INIS)

    Krasnykh, Anatoly

    2008-01-01

    An induction linac cell for a high gradient is discussed. The proposed solid state coreless approach for the induction linac topology (SLIM(reg s ign)) is based on nanosecond mode operation. This mode may have an acceleration gradient comparable with gradients of rf- accelerator structures. The discussed induction system has the high electric efficiency. The key elements are a solid state semiconductor switch and a high electric density dielectric with a thin section length. The energy in the induction system is storied in the magnetic field. The nanosecond current break-up produces the high voltage. The induced voltage is used for acceleration. This manner of an operation allows the use of low voltage elements in the booster part and achieves a high accelerating gradient. The proposed topology was tested in POP (proof of principle) experiments

  1. Three gradients and the perception of flat and curved surfaces.

    Science.gov (United States)

    Cutting, J E; Millard, R T

    1984-06-01

    Researchers of visual perception have long been interested in the perceived slant of a surface and in the gradients that purportedly specify it. Slant is the angle between the line of sight and the tangent to the planar surface at any point, also called the surface normal. Gradients are the sources of information that grade, or change, with visual angle as one looks from one's feet upward to the horizon. The present article explores three gradients--perspective, compression, and density--and the phenomenal impression of flat and curved surfaces. The perspective gradient is measured at right angles to the axis of tilt at any point in the optic array; that is, when looking down a hallway at the tiles of a floor receding in the distance, perspective is measured by the x-axis width of each tile projected on the image plane orthogonal to the line of sight. The compression gradient is the ratio of y/x axis measures on the projected plane. The density gradient is measured by the number of tiles per unit solid visual angle. For flat surfaces and many others, perspective and compression gradients decrease with distance, and the density gradient increases. We discuss the manner in which these gradients change for various types of surfaces. Each gradient is founded on a different assumption about textures on the surfaces around us. In Experiment 1, viewers assessed the three-dimensional character of projections of flat and curved surfaces receding in the distance. They made pairwise judgments of preference and of dissimilarity among eight stimuli in each of four sets. The presence of each gradient was manipulated orthogonally such that each stimulus had zero, one, two, or three gradients appropriate for either a flat surface or a curved surface. Judgments were made were made for surfaces with both regularly shaped and irregularly shaped textures scattered on them. All viewer assessment were then scaled in one dimension. Multiple correlation and regression on the scale values

  2. Nonlinear conjugate gradient methods in micromagnetics

    Directory of Open Access Journals (Sweden)

    J. Fischbacher

    2017-04-01

    Full Text Available Conjugate gradient methods for energy minimization in micromagnetics are compared. The comparison of analytic results with numerical simulation shows that standard conjugate gradient method may fail to produce correct results. A method that restricts the step length in the line search is introduced, in order to avoid this problem. When the step length in the line search is controlled, conjugate gradient techniques are a fast and reliable way to compute the hysteresis properties of permanent magnets. The method is applied to investigate demagnetizing effects in NdFe12 based permanent magnets. The reduction of the coercive field by demagnetizing effects is μ0ΔH = 1.4 T at 450 K.

  3. Comparison of 3- and 20-Gradient Direction Diffusion-Weighted Imaging in a Clinical Subacute Cohort of Patients with Transient Ischemic Attack: Application of Standard Vendor Protocols for Lesion Detection and Final Infarct Size Projection

    Directory of Open Access Journals (Sweden)

    Inger Havsteen

    2017-12-01

    Full Text Available ObjectiveDiffusion tensor imaging may aid brain ischemia assessment but is more time consuming than conventional diffusion-weighted imaging (DWI. We compared 3-gradient direction DWI (3DWI and 20-gradient direction DWI (20DWI standard vendor protocols in a hospital-based prospective cohort of patients with transient ischemic attack (TIA for lesion detection, lesion brightness, predictability of persisting infarction, and final infarct size.MethodsWe performed 3T-magnetic resonance imaging including diffusion and T2-fluid attenuated inversion recovery (FLAIR within 72 h and 8 weeks after ictus. Qualitative lesion brightness was assessed by visual inspection. We measured lesion area and brightness with manual regions of interest and compared with homologous normal tissue.Results117 patients with clinical TIA showed 78 DWI lesions. 2 lesions showed only on 3DWI. No lesions were uniquely 20DWI positive. 3DWI was visually brightest for 34 lesions. 12 lesions were brightest on 20DWI. The median 3DWI lesion area was larger for lesions equally bright, or brightest on 20DWI [median (IQR 39 (18–95 versus 18 (10–34 mm2, P = 0.007]. 3DWI showed highest measured relative lesion signal intensity [median (IQR 0.77 (0.48–1.17 versus 0.58 (0.34–0.81, P = 0.0006]. 3DWI relative lesion signal intensity was not correlated to absolute signal intensity, but 20DWI performed less well for low-contrast lesions. 3DWI lesion size was an independent predictor of persistent infarction. 3-gradient direction apparent diffusion coefficient areas were closest to 8-week FLAIR infarct size.Conclusion3DWI detected more lesions and had higher relative lesion SI than 20DWI. 20DWI appeared blurred and did not add information.Clinical Trial Registrationhttp://www.clinicaltrials.gov. Unique Identifier NCT01531946.

  4. SU-F-T-255: Accuracy and Precision of Dynamic Tracking Irradiation with VERO-4DRT System

    International Nuclear Information System (INIS)

    Hayashi, N; Takada, Y; Mizuno, T; Nakae, H; Murai, T

    2016-01-01

    Purpose: The VERO-4DRT system is able to provide dynamic tracking irradiation (DTI) for the target with respiratory motion. This technique requires enough commissioning for clinical implementation. The purpose of this study is to make sure the accuracy and precision of DTI using VERO- 4DRT through commissioning from fundamental evaluation to end-to-end test. Method: We evaluated several contents for DTI commissioning: the accuracy of absorption dose at isocenter in DTI, the field size and penumbra of DTI, the accuracy of 4D modeling in DTI. All evaluations were performed by respiratory motion phantom (Quasar phantom). These contents were compared the results between static irradiation and DTI. The shape of radiation field was set to square from 3 cm × 3 cm to 10 cm × 10 cm. The micro 3D chamber and Gafchromic EBT3 film were used for absorbed dose and relative dose distribution measurement, respectively. The sine and irregular shaped waves were used for demonstrative respiratory motion. The visicoil was implanted into the phantom for guidance of respiratory motion. The respiration patterns of frequency and motion amount were set to 10–15 BPM and 1–2 cm, respectively. Results: As the result of absorbed dose of DTI in comparison with static irradiation, the average dose error at isocenter was 0.5% even though various respiratory patterns were set on. As the result of relative dose distribution, the field size (set it on 50% dose line) was not significantly changed in all respiratory patterns. However, the penumbra was larger in greater respiratory motion (up to 4.1 mm). The 4D modeling coincidence between actual and created waves was within 1%. Conclusion: The DTI using VERO-4DRT can provide sufficient accuracy and precision in absorbed dose and distribution. However, the patientspecific quantitative internal margin corresponding respiratory motion should be taken into consideration with image guidance.

  5. SU-F-T-255: Accuracy and Precision of Dynamic Tracking Irradiation with VERO-4DRT System

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, N [Graduate school of Health Sciences, Fujita Health University, Tayoake, Aichi (Japan); Takada, Y; Mizuno, T; Nakae, H [Department of Radiology, Ogaki Tokushukai Hospital, Ogaki, Gifu (Japan); Murai, T [Department of Radiation Oncology, Nagoya City University, Nagoya, Aichi (Japan)

    2016-06-15

    Purpose: The VERO-4DRT system is able to provide dynamic tracking irradiation (DTI) for the target with respiratory motion. This technique requires enough commissioning for clinical implementation. The purpose of this study is to make sure the accuracy and precision of DTI using VERO- 4DRT through commissioning from fundamental evaluation to end-to-end test. Method: We evaluated several contents for DTI commissioning: the accuracy of absorption dose at isocenter in DTI, the field size and penumbra of DTI, the accuracy of 4D modeling in DTI. All evaluations were performed by respiratory motion phantom (Quasar phantom). These contents were compared the results between static irradiation and DTI. The shape of radiation field was set to square from 3 cm × 3 cm to 10 cm × 10 cm. The micro 3D chamber and Gafchromic EBT3 film were used for absorbed dose and relative dose distribution measurement, respectively. The sine and irregular shaped waves were used for demonstrative respiratory motion. The visicoil was implanted into the phantom for guidance of respiratory motion. The respiration patterns of frequency and motion amount were set to 10–15 BPM and 1–2 cm, respectively. Results: As the result of absorbed dose of DTI in comparison with static irradiation, the average dose error at isocenter was 0.5% even though various respiratory patterns were set on. As the result of relative dose distribution, the field size (set it on 50% dose line) was not significantly changed in all respiratory patterns. However, the penumbra was larger in greater respiratory motion (up to 4.1 mm). The 4D modeling coincidence between actual and created waves was within 1%. Conclusion: The DTI using VERO-4DRT can provide sufficient accuracy and precision in absorbed dose and distribution. However, the patientspecific quantitative internal margin corresponding respiratory motion should be taken into consideration with image guidance.

  6. Assessing public health policy approaches to level-up the gradient in health inequalities: the Gradient Evaluation Framework.

    Science.gov (United States)

    Davies, J K; Sherriff, N S

    2014-03-01

    This paper seeks to introduce and analyse the development of the Gradient Evaluation Framework (GEF) to facilitate evaluation of policy actions for their current or future use in terms of their 'gradient friendliness'. In particular, this means their potential to level-up the gradient in health inequalities by addressing the social determinants of health and thereby reducing decision-makers' chances of error when developing such policy actions. A qualitative developmental study to produce a policy-based evaluation framework. The scientific basis of GEF was developed using a comprehensive consensus-building process. This process followed an initial narrative review, based on realist review principles, which highlighted the need for production of a dedicated evaluation framework. The consensus-building process included expert workshops, a pretesting phase, and external peer review, together with support from the Gradient project Scientific Advisory Group and all Gradient project partners, including its Project Steering Committee. GEF is presented as a flexible policy tool resulting from a consensus-building process involving experts from 13 European countries. The theoretical foundations which underpin GEF are discussed, together with a range of practical challenges. The importance of systematic evaluation at each stage of the policy development and implementation cycle is highlighted, as well as the socio-political context in which policy actions are located. GEF offers potentially a major contribution to the public health field in the form of a practical, policy-relevant and common frame of reference for the evaluation of public health interventions that aim to level-up the social gradient in health inequalities. Further research, including the need for practical field testing of GEF and the exploration of alternative presentational formats, is recommended. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  7. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir; Wang, Hui; Tsvankin, Ilya; Diaz, Esteban; Alkhalifah, Tariq Ali

    2016-01-01

    -power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space

  8. Income inequality and socioeconomic gradients in mortality.

    Science.gov (United States)

    Wilkinson, Richard G; Pickett, Kate E

    2008-04-01

    We investigated whether the processes underlying the association between income inequality and population health are related to those responsible for the socioeconomic gradient in health and whether health disparities are smaller when income differences are narrower. We used multilevel models in a regression analysis of 10 age- and cause-specific US county mortality rates on county median household incomes and on state income inequality. We assessed whether mortality rates more closely related to county income were also more closely related to state income inequality. We also compared mortality gradients in more- and less-equal states. Mortality rates more strongly associated with county income were more strongly associated with state income inequality: across all mortality rates, r= -0.81; P=.004. The effect of state income inequality on the socioeconomic gradient in health varied by cause of death, but greater equality usually benefited both wealthier and poorer counties. Although mortality rates with steep socioeconomic gradients were more sensitive to income distribution than were rates with flatter gradients, narrower income differences benefit people in both wealthy and poor areas and may, paradoxically, do little to reduce health disparities.

  9. Gradient algorithm applied to laboratory quantum control

    International Nuclear Information System (INIS)

    Roslund, Jonathan; Rabitz, Herschel

    2009-01-01

    The exploration of a quantum control landscape, which is the physical observable as a function of the control variables, is fundamental for understanding the ability to perform observable optimization in the laboratory. For high control variable dimensions, trajectory-based methods provide a means for performing such systematic explorations by exploiting the measured gradient of the observable with respect to the control variables. This paper presents a practical, robust, easily implemented statistical method for obtaining the gradient on a general quantum control landscape in the presence of noise. In order to demonstrate the method's utility, the experimentally measured gradient is utilized as input in steepest-ascent trajectories on the landscapes of three model quantum control problems: spectrally filtered and integrated second harmonic generation as well as excitation of atomic rubidium. The gradient algorithm achieves efficiency gains of up to approximately three times that of the standard genetic algorithm and, as such, is a promising tool for meeting quantum control optimization goals as well as landscape analyses. The landscape trajectories directed by the gradient should aid in the continued investigation and understanding of controlled quantum phenomena.

  10. Primordial vorticity and gradient expansion

    CERN Document Server

    Giovannini, Massimo

    2012-01-01

    The evolution equations of the vorticities of the electrons, ions and photons in a pre-decoupling plasma are derived, in a fully inhomogeneous geometry, by combining the general relativistic gradient expansion and the drift approximation within the Adler-Misner-Deser decomposition. The vorticity transfer between the different species is discussed in this novel framework and a set of general conservation laws, connecting the vorticities of the three-component plasma with the magnetic field intensity, is derived. After demonstrating that a source of large-scale vorticity resides in the spatial gradients of the geometry and of the electromagnetic sources, the total vorticity is estimated to lowest order in the spatial gradients and by enforcing the validity of the momentum constraint. By acknowledging the current bounds on the tensor to scalar ratio in the (minimal) tensor extension of the $\\Lambda$CDM paradigm the maximal comoving magnetic field induced by the total vorticity turns out to be, at most, of the or...

  11. Review of diffusion tensor imaging and its application in children

    Energy Technology Data Exchange (ETDEWEB)

    Vorona, Gregory A. [Children' s Hospital of Richmond at Virginia Commonwealth University, Department of Radiology, Richmond, VA (United States); Berman, Jeffrey I. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2015-09-15

    Diffusion MRI is an imaging technique that uses the random motion of water to probe tissue microstructure. Diffusion tensor imaging (DTI) can quantitatively depict the organization and connectivity of white matter. Given the non-invasiveness of the technique, DTI has become a widely used tool for researchers and clinicians to examine the white matter of children. This review covers the basics of diffusion-weighted imaging and diffusion tensor imaging and discusses examples of their clinical application in children. (orig.)

  12. Diffusion tensor imaging for long-term follow-up of corticospinal tract degeneration in amyotrophic lateral sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, S.; Ehrenreich, H. [Max-Planck-Institute for Experimental Medicine, Georg-August-University, Hermann-Rein-Strasse 3, 37075, Goettingen (Germany); Departments of Neurology and Psychiatry, Georg-August-University, Goettingen (Germany); Finsterbusch, J.; Frahm, J. [Biomedizinische NMR Forschungs GmbH, Max-Planck-Institute for Biophysical Chemistry, Georg-August-University, Goettingen (Germany); Weishaupt, J.H. [Departments of Neurology and Psychiatry, Georg-August-University, Goettingen (Germany); Khorram-Sefat, D. [Department of Neuroradiology, Georg-August-University, Goettingen (Germany)

    2003-09-01

    Amyotrophic lateral sclerosis (ALS) is a predominantly clinical and electromyographic diagnosis. Conventional MRI reveals atrophy of the motor system, particularly the pyramidal tract, in the advanced stages but does not provide a sensitive measure of disease progression. Three patients with different principal symptoms of ALS, i.e., with predominant involvement of the upper (UMN) or lower (UMN) motor neurons, or bulbar disease, respectively, underwent serial clinical examination including lung function tests, conventional MRI, and diffusion tensor imaging (DTI). MRI demonstrated changes in of the pyramidal tract without measurable variation on follow-up. The patient with UMN involvement showed remarkable progressive loss of diffusion anisotropy in the pyramidal tract. DTI might be useful, together with clinical follow-up, as an objective morphological marker in therapeutic trials. (orig.)

  13. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  14. Gradient biomaterials and their influences on cell migration

    Science.gov (United States)

    Wu, Jindan; Mao, Zhengwei; Tan, Huaping; Han, Lulu; Ren, Tanchen; Gao, Changyou

    2012-01-01

    Cell migration participates in a variety of physiological and pathological processes such as embryonic development, cancer metastasis, blood vessel formation and remoulding, tissue regeneration, immune surveillance and inflammation. The cells specifically migrate to destiny sites induced by the gradually varying concentration (gradient) of soluble signal factors and the ligands bound with the extracellular matrix in the body during a wound healing process. Therefore, regulation of the cell migration behaviours is of paramount importance in regenerative medicine. One important way is to create a microenvironment that mimics the in vivo cellular and tissue complexity by incorporating physical, chemical and biological signal gradients into engineered biomaterials. In this review, the gradients existing in vivo and their influences on cell migration are briefly described. Recent developments in the fabrication of gradient biomaterials for controlling cellular behaviours, especially the cell migration, are summarized, highlighting the importance of the intrinsic driving mechanism for tissue regeneration and the design principle of complicated and advanced tissue regenerative materials. The potential uses of the gradient biomaterials in regenerative medicine are introduced. The current and future trends in gradient biomaterials and programmed cell migration in terms of the long-term goals of tissue regeneration are prospected. PMID:23741610

  15. Recognition of handwritten characters using local gradient feature descriptors

    NARCIS (Netherlands)

    Surinta, Olarik; Karaaba, Mahir F.; Schomaker, Lambert R.B.; Wiering, Marco A.

    2015-01-01

    Abstract In this paper we propose to use local gradient feature descriptors, namely the scale invariant feature transform keypoint descriptor and the histogram of oriented gradients, for handwritten character recognition. The local gradient feature descriptors are used to extract feature vectors

  16. HG2006 Workshop on High-Gradient Radio Frequency

    CERN Multimedia

    2006-01-01

    Meeting to be held at CERN on 25-27 September 2006 in Room 40/S2-B01 (Building 40). The objective of the workshop is to bring the high-gradient RF community together to present and discuss recent theoretical and experimental developments. Significant progress has recently been made in understanding the basic physics of rf breakdown and developing techniques for achieving higher gradients. This workshop should contribute to maintaining these efforts and to promoting contacts and collaboration. The scientific programme will be organized in half day sessions dedicated to: High-gradient rf experimental results Theory and computation High-gradient technology, materials and processing Specialized experiments on related high-gradient or high-power phenomenon like dc discharge and pulsed surface heating Reports from collaborations and projects. Each session will consist of selected presentations followed by a dedicated discussion. Information about the meeting and participant registration is available at http...

  17. Relativistic klystrons for high-gradient accelerators

    International Nuclear Information System (INIS)

    Westenskow, G.A.; Aalberts, D.P.; Boyd, J.K.; Deis, G.A.; Houck, T.L.; Orzechowski, T.J.; Ryne, R.D.; Yu, S.S.; Allen, M.A.; Callin, R.S.; Deruyter, H.; Eppley, K.R.; Fant, K.S.; Fowkes, W.R.; Hoag, H.A.; Koontz, R.F.; Lavine, T.L.; Loew, G.A.; Miller, R.H.; Ruth, R.D.; Vlieks, A.E.; Wang, J.W.; Hopkins, D.B.; Sessler, A.M.; Haimson, J.; Mecklenburg, B.

    1991-01-01

    Experimental work is being performed by collaborators at LLNL, SLAC, and LBL to investigate relativistic klystrons as a possible rf power source for future high-gradient accelerators. The authors have learned how to overcome their previously reported problem of high power rf pulse shortening and have achieved peak rf power levels of 330 MW using an 11.4-GHz high-gain tube with multiple output structures. In these experiments the rf pulse is of the same duration as the beam current pulse. In addition, experiments have been performed on two short sections of a high-gradient accelerator using the rf power from a relativistic klystron. An average accelerating gradient of 84 MV/m has been achieved with 80-MW of rf power

  18. Conjugate gradient algorithms using multiple recursions

    Energy Technology Data Exchange (ETDEWEB)

    Barth, T.; Manteuffel, T.

    1996-12-31

    Much is already known about when a conjugate gradient method can be implemented with short recursions for the direction vectors. The work done in 1984 by Faber and Manteuffel gave necessary and sufficient conditions on the iteration matrix A, in order for a conjugate gradient method to be implemented with a single recursion of a certain form. However, this form does not take into account all possible recursions. This became evident when Jagels and Reichel used an algorithm of Gragg for unitary matrices to demonstrate that the class of matrices for which a practical conjugate gradient algorithm exists can be extended to include unitary and shifted unitary matrices. The implementation uses short double recursions for the direction vectors. This motivates the study of multiple recursion algorithms.

  19. The Potential of Tropospheric Gradients for Regional Precipitation Prediction

    Science.gov (United States)

    Boisits, Janina; Möller, Gregor; Wittmann, Christoph; Weber, Robert

    2017-04-01

    Changes of temperature and humidity in the neutral atmosphere cause variations in tropospheric path delays and tropospheric gradients. By estimating zenith wet delays (ZWD) and gradients using a GNSS reference station network the obtained time series provide information about spatial and temporal variations of water vapour in the atmosphere. Thus, GNSS-based tropospheric parameters can contribute to the forecast of regional precipitation events. In a recently finalized master thesis at TU Wien the potential of tropospheric gradients for weather prediction was investigated. Therefore, ZWD and gradient time series at selected GNSS reference stations were compared to precipitation data over a period of six months (April to September 2014). The selected GNSS stations form two test areas within Austria. All required meteorological data was provided by the Central Institution for Meteorology and Geodynamics (ZAMG). Two characteristics in ZWD and gradient time series can be anticipated in case of an approaching weather front. First, an induced asymmetry in tropospheric delays results in both, an increased magnitude of the gradient and in gradients pointing towards the weather front. Second, an increase in ZWD reflects the increased water vapour concentration right before a precipitation event. To investigate these characteristics exemplary test events were processed. On the one hand, the sequence of the anticipated increase in ZWD at each GNSS station obtained by cross correlation of the time series indicates the direction of the approaching weather front. On the other hand, the corresponding peak in gradient time series allows the deduction of the direction of movement as well. To verify the results precipitation data from ZAMG was used. It can be deduced, that tropospheric gradients show high potential for predicting precipitation events. While ZWD time series rather indicate the orientation of the air mass boundary, gradients rather indicate the direction of movement

  20. Semiautomated system for the production and analysis of sucrose density gradients

    International Nuclear Information System (INIS)

    Lange, C.S.; Liberman, D.F.

    1974-01-01

    A semiautomated system in DNA damage studies permitting considerable accuracy, speed, and reproducibility in the making and fractionation of sucrose density gradients is described. The system consists of a modified Beckman gradient forming device that makes six gradients simultaneously and delivers them into six 12.5 ml polyallomer centrifuge tubes in such a manner that new material is continuously added to the meniscus of the gradient. The gradients are fractionated three at a time and up to 100 fractions per gradient can be collected automatically directly into scintillation vials with a choice of drop counting or time mode with rinse and automatic addition of scintillation fluid to each vial. The system can process up to six gradients per hour but centrifugation time is usually the limiting factor. With neutral sucrose gradients, sharp, reproducible, monodisperse peaks containing up to 100 percent of the gradient radioactivity are usually obtained but a smaller monodisperse peak containing as little as 3.5 percent of the gradient radioactivity can be detected under conditions where some pairs of molecules might tangle or dimerize. The resolution and reproducibility of this system when used with neutral sucrose gradients is at least the equal if not superior to that commonly claimed for alkaline sucrose gradients. (U.S.)

  1. On lower order strain gradient plasticity theories

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Hutchinson, J. W.

    2002-01-01

    By way of numerical examples, this paper explores the nature of solutions to a class of strain gradient plasticity theories that employ conventional stresses, equilibrium equations and boundary conditions. Strain gradients come into play in these modified conventional theories only to alter...

  2. Gentamicin concentration gradients in scala tympani perilymph following systemic applications.

    Science.gov (United States)

    Hahn, Hartmut; Salt, Alec N; Schumacher, Ulrike; Plontke, Stefan K

    2013-01-01

    It has been shown in prior studies that round window membrane (RWM) application of gentamicin produced a robust basal-apical concentration gradient in the perilymph of scala tympani (ST) with peak concentrations in the basal turn of ST. These gradients potentially contribute to the clinical efficacy and safety of intratympanic gentamicin applications for the treatment of Ménière's disease. The present study aimed to establish the distribution of gentamicin along ST perilymph after systemic applications. Gentamicin sulfate was applied intravenously in the amounts of 100, 300 and 600 mg/kg body weight (BW) over a period of 3 h or as a 300 mg/kg BW subcutaneous bolus injection. At 3 and 5 h after the start of the application perilymph of ST was aspirated from the cochlea apex of the right and left cochlea, respectively, and 10 sequential 1-µl perilymph samples from the apex of each cochlea were quantitatively analyzed using a fluorescence polarization immunoassay. In contrast to local RWM delivery, systemic application of gentamicin resulted in the highest perilymph levels in the apex of the cochlea with decreasing concentrations towards the basal regions of ST. The absolute gentamicin concentrations increased with the amount of drug applied and time before sampling. While it is likely that the basal-apical gradient measured after local drug applications to the round window niche is the result of the direct uptake of drugs into the perilymph of the ST, distribution by diffusion and a very low perilymph flow towards the cochlear apex, computer simulations suggested that the apical-basal gradient observed with these systemic applications can be explained by higher entry rates of gentamicin in the apex compared to the basal turns of the cochlea. It is also possible that gentamicin enters perilymph indirectly from the blood via the endolymph. In this case the faster kinetics in apical turns could be due to the smaller cross-sectional area of ST relative to endolymph in

  3. Scattering-angle based filtering of the waveform inversion gradients

    KAUST Repository

    Alkhalifah, Tariq Ali

    2014-01-01

    Full waveform inversion (FWI) requires a hierarchical approach to maneuver the complex non-linearity associated with the problem of velocity update. In anisotropic media, the non-linearity becomes far more complex with the potential trade-off between the multiparameter description of the model. A gradient filter helps us in accessing the parts of the gradient that are suitable to combat the potential non-linearity and parameter trade-off. The filter is based on representing the gradient in the time-lag normalized domain, in which the low scattering angle of the gradient update is initially muted out in the FWI implementation, in what we may refer to as a scattering angle continuation process. The result is a low wavelength update dominated by the transmission part of the update gradient. In this case, even 10 Hz data can produce vertically near-zero wavenumber updates suitable for a background correction of the model. Relaxing the filtering at a later stage in the FWI implementation allows for smaller scattering angles to contribute higher-resolution information to the model. The benefits of the extended domain based filtering of the gradient is not only it's ability in providing low wavenumber gradients guided by the scattering angle, but also in its potential to provide gradients free of unphysical energy that may correspond to unrealistic scattering angles.

  4. Scattering-angle based filtering of the waveform inversion gradients

    KAUST Repository

    Alkhalifah, Tariq Ali

    2014-11-22

    Full waveform inversion (FWI) requires a hierarchical approach to maneuver the complex non-linearity associated with the problem of velocity update. In anisotropic media, the non-linearity becomes far more complex with the potential trade-off between the multiparameter description of the model. A gradient filter helps us in accessing the parts of the gradient that are suitable to combat the potential non-linearity and parameter trade-off. The filter is based on representing the gradient in the time-lag normalized domain, in which the low scattering angle of the gradient update is initially muted out in the FWI implementation, in what we may refer to as a scattering angle continuation process. The result is a low wavelength update dominated by the transmission part of the update gradient. In this case, even 10 Hz data can produce vertically near-zero wavenumber updates suitable for a background correction of the model. Relaxing the filtering at a later stage in the FWI implementation allows for smaller scattering angles to contribute higher-resolution information to the model. The benefits of the extended domain based filtering of the gradient is not only it\\'s ability in providing low wavenumber gradients guided by the scattering angle, but also in its potential to provide gradients free of unphysical energy that may correspond to unrealistic scattering angles.

  5. Integral Field Spectroscopy Surveys: Oxygen Abundance Gradients

    Science.gov (United States)

    Sánchez, S. F.; Sánchez-Menguiano, L.

    2017-07-01

    We present here the recent results on our understanding of oxygen abundance gradients derived using Integral Field Spectroscopic surveys. In particular we analyzed more than 2124 datacubes corresponding to individual objects observed by the CALIFA (˜ 734 objects) and the public data by MaNGA (˜ 1390 objects), deriving the oxygen abundance gradient for each galaxy. We confirm previous results that indicate that the shape of this gradient is very similar for all galaxies with masses above 109.5M⊙, presenting in average a very similar slope of ˜ -0.04 dex within 0.5-2.0 re, with a possible drop in the inner regions (r109.5M⊙) the gradient seems to be flatter than for more massive ones. All these results agree with an inside-out growth of massive galaxies and indicate that low mass ones may still be growing in an outside in phase.

  6. Exploring sex differences in the adult zebra finch brain: In vivo diffusion tensor imaging and ex vivo super-resolution track density imaging.

    Science.gov (United States)

    Hamaide, Julie; De Groof, Geert; Van Steenkiste, Gwendolyn; Jeurissen, Ben; Van Audekerke, Johan; Naeyaert, Maarten; Van Ruijssevelt, Lisbeth; Cornil, Charlotte; Sijbers, Jan; Verhoye, Marleen; Van der Linden, Annemie

    2017-02-01

    Zebra finches are an excellent model to study the process of vocal learning, a complex socially-learned tool of communication that forms the basis of spoken human language. So far, structural investigation of the zebra finch brain has been performed ex vivo using invasive methods such as histology. These methods are highly specific, however, they strongly interfere with performing whole-brain analyses and exclude longitudinal studies aimed at establishing causal correlations between neuroplastic events and specific behavioral performances. Therefore, the aim of the current study was to implement an in vivo Diffusion Tensor Imaging (DTI) protocol sensitive enough to detect structural sex differences in the adult zebra finch brain. Voxel-wise comparison of male and female DTI parameter maps shows clear differences in several components of the song control system (i.e. Area X surroundings, the high vocal center (HVC) and the lateral magnocellular nucleus of the anterior nidopallium (LMAN)), which corroborate previous findings and are in line with the clear behavioral difference as only males sing. Furthermore, to obtain additional insights into the 3-dimensional organization of the zebra finch brain and clarify findings obtained by the in vivo study, ex vivo DTI data of the male and female brain were acquired as well, using a recently established super-resolution reconstruction (SRR) imaging strategy. Interestingly, the SRR-DTI approach led to a marked reduction in acquisition time without interfering with the (spatial and angular) resolution and SNR which enabled to acquire a data set characterized by a 78μm isotropic resolution including 90 diffusion gradient directions within 44h of scanning time. Based on the reconstructed SRR-DTI maps, whole brain probabilistic Track Density Imaging (TDI) was performed for the purpose of super resolved track density imaging, further pushing the resolution up to 40μm isotropic. The DTI and TDI maps realized atlas

  7. Prevalence, clinical and echocardiographic characteristics of various flow and gradient patterns in mild or moderate aortic stenosis with normal left ventricular ejection fraction.

    Science.gov (United States)

    Tan, Yong-Qiang Benjamin; Ngiam, Jinghao Nicholas; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong

    2016-10-15

    Paradoxical low-flow aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) has only been described in severe AS. Controversy surrounds prognosis and management but no studies have reported this phenomenon in mild or moderate AS. We investigated the prevalence of flow and gradient patterns in this population, characterising their clinical and echocardiographic profile. Consecutive subjects (n=1362) with isolated AS: mild (n=462, aortic valve area≥1.5cm(2), 2.5m/sgradient patterns. In mild AS, 130 (28%) had low-flow. Lower left ventricular mass index (LVMI) (97.0±28.5vs116.4±2.3g/m(2),p<0.001), higher percentage of concentric remodelling (40%vs6%,p<0.001) and hypertrophy (43%vs40%,p<0.001) and lower end-systolic wall stress (ESWS) (57.6±1.60vs67.7±19.6dyn/cm(2),p=0.014) were independently associated with low-flow. Similarly, in moderate AS, 297 (33%) had low-flow. Older age (73.4±14.8vs69.5±16.5,p=0.027), lower LVMI (88.6±25.9vs118.0±36.5,p<0.001), higher percentage of concentric remodelling (46%vs8%,p<0.001) and lower ESWS (59.9±18.3vs70.5±19.7,p<0.001) were independently associated with low-flow. Despite moderate AS, most had lower mean pressure gradients, especially subjects with concentric remodelling. In the entire cohort, low-flow patients had more concentric remodelling (43%vs7%,p<0.001) and less eccentric hypertrophy (2%vs27%,p<0.001) compared to normal flow. Low-flow AS with normal LVEF is observed in mild or moderate AS, in up to a third of the cases. These patients had different LV structure compared to normal-flow, with more concentric remodelling. Further studies are warranted. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Feasibility of creating a high-resolution 3D diffusion tensor imaging based atlas of the human brainstem: a case study at 11.7 T.

    Science.gov (United States)

    Aggarwal, Manisha; Zhang, Jiangyang; Pletnikova, Olga; Crain, Barbara; Troncoso, Juan; Mori, Susumu

    2013-07-01

    A three-dimensional stereotaxic atlas of the human brainstem based on high resolution ex vivo diffusion tensor imaging (DTI) is introduced. The atlas consists of high resolution (125-255 μm isotropic) three-dimensional DT images of the formalin-fixed brainstem acquired at 11.7 T. The DTI data revealed microscopic neuroanatomical details, allowing three-dimensional visualization and reconstruction of fiber pathways including the decussation of the pyramidal tract fibers, and interdigitating fascicles of the corticospinal and transverse pontine fibers. Additionally, strong gray-white matter contrasts in the apparent diffusion coefficient (ADC) maps enabled precise delineation of gray matter nuclei in the brainstem, including the cranial nerve and the inferior olivary nuclei. Comparison with myelin-stained histology shows that at the level of resolution achieved in this study, the structural details resolved with DTI contrasts in the brainstem were comparable to anatomical delineation obtained with histological sectioning. Major neural structures delineated from DTI contrasts in the brainstem are segmented and three-dimensionally reconstructed. Further, the ex vivo DTI data are nonlinearly mapped to a widely-used in vivo human brain atlas, to construct a high-resolution atlas of the brainstem in the Montreal Neurological Institute (MNI) stereotaxic coordinate space. The results demonstrate the feasibility of developing a 3D DTI based atlas for detailed characterization of brainstem neuroanatomy with high resolution and contrasts, which will be a useful resource for research and clinical applications. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Complex Surface Concentration Gradients by Stenciled "Electro Click Chemistry"

    DEFF Research Database (Denmark)

    Hansen, Thomas Steen; Lind, Johan Ulrik; Daugaard, Anders Egede

    2010-01-01

    Complex one- or two-dimensional concentration gradients of alkynated molecules are produced on azidized conducting polymer substrates by stenciled "electro click chemistry". The latter describes the local electrochemical generation of catalytically active Cu(I) required to complete a "click...... reaction" between alkynes and azides at room temperature. A stencil on the counter electrode defines the shape and multiplicity of the gradient(s) on the conducting polymer substrate, while the specific reaction conditions control gradient steepness and the maximum concentration deposited. Biologically...

  10. Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Loenneker, Thomas; Barta, Gerd; Bellemann, Matthias E.; Hennig, Juergen; Fischer, Joachim E.; Il'yasov, Kamil A.

    2006-01-01

    The objectives were to study the ''impact'' of the magnetic field strength on diffusion tensor imaging (DTI) metrics and also to determine whether magnetic-field-related differences in T2-relaxation times of brain tissue influence DTI measurements. DTI was performed on 12 healthy volunteers at 1.5 and 3.0 Tesla (within 2 h) using identical DTI scan parameters. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured at multiple gray and white matter locations. ADC and FA values were compared and analyzed for statistically significant differences. In addition, DTI measurements were performed at different echo times (TE) for both field strengths. ADC values for gray and white matter were statistically significantly lower at 3.0 Tesla compared with 1.5 Tesla (% change between -1.94% and -9.79%). FA values were statistically significantly higher at 3.0 Tesla compared with 1.5 Tesla (% change between +4.04 and 11.15%). ADC and FA values are not significantly different for TE=91 ms and TE=125 ms. Thus, ADC and FA values vary with the used field strength. Comparative clinical studies using ADC or FA values should consequently compare ADC or FA results with normative ADC or FA values that have been determined for the field strength used. (orig.)

  11. Stereoscopic Visualization of Diffusion Tensor Imaging Data: A Comparative Survey of Visualization Techniques

    International Nuclear Information System (INIS)

    Raslan, O.; Debnam, J.M.; Ketonen, L.; Kumar, A.J.; Schellingerhout, D.; Wang, J.

    2013-01-01

    Diffusion tensor imaging (DTI) data has traditionally been displayed as a gray scale functional anisotropy map (GSFM) or color coded orientation map (CCOM). These methods use black and white or color with intensity values to map the complex multidimensional DTI data to a two-dimensional image. Alternative visualization techniques, such as V m ax maps utilize enhanced graphical representation of the principal eigenvector by means of a headless arrow on regular non stereoscopic (VM) or stereoscopic display (VMS). A survey of clinical utility of patients with intracranial neoplasms was carried out by 8 neuro radiologists using traditional and nontraditional methods of DTI display. Pairwise comparison studies of 5 intracranial neoplasms were performed with a structured questionnaire comparing GSFM, CCOM, VM, and VMS. Six of 8 neuro radiologists favored V m ax maps over traditional methods of display (GSFM and CCOM). When comparing the stereoscopic (VMS) and the non-stereoscopic (VM) modes, 4 favored VMS, 2 favored VM, and 2 had no preference. In conclusion, processing and visualizing DTI data stereoscopically is technically feasible. An initial survey of users indicated that V m ax based display methodology with or without stereoscopic visualization seems to be preferred over traditional methods to display DTI data.

  12. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, C. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; CNR-INFM CRS-Soft, La Sapienza-Univ. Roma (Italy); Enrico Fern Center, Roma (Italy); Boss, A.; Martirosian, P.; Steidle, G.; Schick, F. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; Lindig, T.M. [Enrico Fern Center, Roma (Italy); Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS; Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Maetzler, W. [Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Claussen, C.D. [Radiologische Universitaetsklinik, Tuebingen (Germany). Abt. fuer Radiologische Diagnostik; Klose, U. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS

    2007-03-15

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 {+-} 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 {+-} 0.08, MD = 0.84 {+-} 0.12, 3.0 T: FA = 0.74 {+-} 0.04, MD = 0.93 {+-} 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 {+-} 3.8% in FA (0.40 {+-} 0.03) and an increase of 50.3 {+-} 5.6% in MD (1.40 {+-} 0.05) were found in the ALS patient. (orig.)

  13. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    International Nuclear Information System (INIS)

    Rossi, C.; Boss, A.; Martirosian, P.; Steidle, G.; Schick, F.; Lindig, T.M.; Radiologische Universitaetsklinik, Tuebingen; Universitaetsklinikum Tuebingen; Maetzler, W.; Claussen, C.D.; Klose, U.

    2007-01-01

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 ± 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 ± 0.08, MD = 0.84 ± 0.12, 3.0 T: FA 0.74 ± 0.04, MD = 0.93 ± 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 ± 3.8% in FA (0.40 ± 0.03) and an increase of 50.3 ± 5.6% in MD (1.40 ± 0.05) were found in the ALS patient. (orig.)

  14. Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-07-01

    The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic resonance scanner using a 15-channel knee coil. The EPI was performed at a b value of 500 s/mm2 without slice acceleration (conventional DTI) as well as with 2-fold and 3-fold acceleration. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in all 3 acquisitions. Fiber tracking performance was compared between the acquisitions regarding the number of tracks, average track length, and anatomical precision using multivariate analysis of variance and Mann-Whitney U tests. Acquisition time was 7:24 minutes for conventional DTI, 3:53 minutes for 2-fold acceleration, and 2:38 minutes for 3-fold acceleration. Overall FA and MD values ranged from 0.220 to 0.378 and 1.595 to 1.829 mm2/s, respectively. Two-fold acceleration yielded similar FA and MD values (P ≥ 0.901) and similar fiber tracking performance compared with conventional DTI. Three-fold acceleration resulted in comparable MD (P = 0.199) but higher FA values (P = 0.006) and significantly impaired fiber tracking in the soleus and tibialis anterior muscles (number of tracks, P DTI of skeletal muscle with similar image quality and quantification accuracy of diffusion parameters. This may increase the clinical applicability of muscle anisotropy measurements.

  15. Vertical gradients of sunspot magnetic fields

    Science.gov (United States)

    Hagyard, M. J.; Teuber, D.; West, E. A.; Tandberg-Hanssen, E.; Henze, W., Jr.; Beckers, J. M.; Bruner, M.; Hyder, C. L.; Woodgate, B. E.

    1983-01-01

    The results of a Solar Maximum Mission (SMM) guest investigation to determine the vertical gradients of sunspot magnetic fields for the first time from coordinated observations of photospheric and transition-region fields are described. Descriptions are given of both the photospheric vector field of a sunspot, derived from observations using the NASA Marshall Space Flight Center vector magnetograph, and of the line-of-sight component in the transition region, obtained from the SMM Ultraviolet Spectrometer and Polarimeter instrument. On the basis of these data, vertical gradients of the line-of-sight magnetic field component are calculated using three methods. It is found that the vertical gradient of Bz is lower than values from previous studies and that the transition-region field occurs at a height of approximately 4000-6000 km above the photosphere.

  16. Composition gradients across spiral galaxies II. The stellar mass limit

    International Nuclear Information System (INIS)

    Shields, G.A.; Tinsley, B.M.

    1976-01-01

    The equivalent width of the Hβ emission from H ii regions in spiral galaxies increases with distance from the nucleus. This W (Hβ) gradient is interpreted in terms of a radial gradient in the temperature of the hottest exciting stars. (T/subu/). From Searle's observations of M101, an increase Δ log T/subu/=0.02--0.13 from the intermediate to outermost spiral arms of M101 is inferred. There is also a radial decrease in the metal abundance (Z) across M101, and the T/subu/ gradient is consistent with the prediction of Kahn's recent theory that the upper mass limit for star formation should be smaller in regions of high Z. It is noted also that, even in the absence of changes in the upper mass limit, a T/subu/ gradient is expected because metal-rich stars of given mass have smaller effective temperatures. Several observational and theoretical improvements are needed before firm conclusions can be drawn, but it is clear that the presence of a T/subu/ gradient may lead to several important systematic changes in the interpretation of gradients in the properties of H ii regions across galaxies. A T/subu/ gradient reduces the Z gradient that is inferred from emission-line ratios, and it may help to explain why O ii is strong in the innermost regions where O iii is weak. A T/subu/ gradient may also partly camouflage a helium abundance gradient

  17. Comparison of genetic algorithms with conjugate gradient methods

    Science.gov (United States)

    Bosworth, J. L.; Foo, N. Y.; Zeigler, B. P.

    1972-01-01

    Genetic algorithms for mathematical function optimization are modeled on search strategies employed in natural adaptation. Comparisons of genetic algorithms with conjugate gradient methods, which were made on an IBM 1800 digital computer, show that genetic algorithms display superior performance over gradient methods for functions which are poorly behaved mathematically, for multimodal functions, and for functions obscured by additive random noise. Genetic methods offer performance comparable to gradient methods for many of the standard functions.

  18. Full Gradient Solution to Adaptive Hybrid Control

    Science.gov (United States)

    Bean, Jacob; Schiller, Noah H.; Fuller, Chris

    2017-01-01

    This paper focuses on the adaptation mechanisms in adaptive hybrid controllers. Most adaptive hybrid controllers update two filters individually according to the filtered reference least mean squares (FxLMS) algorithm. Because this algorithm was derived for feedforward control, it does not take into account the presence of a feedback loop in the gradient calculation. This paper provides a derivation of the proper weight vector gradient for hybrid (or feedback) controllers that takes into account the presence of feedback. In this formulation, a single weight vector is updated rather than two individually. An internal model structure is assumed for the feedback part of the controller. The full gradient is equivalent to that used in the standard FxLMS algorithm with the addition of a recursive term that is a function of the modeling error. Some simulations are provided to highlight the advantages of using the full gradient in the weight vector update rather than the approximation.

  19. Analysis of magnetic gradients to study gravitropism.

    Science.gov (United States)

    Hasenstein, Karl H; John, Susan; Scherp, Peter; Povinelli, Daniel; Mopper, Susan

    2013-01-01

    Gravitropism typically is generated by dense particles that respond to gravity. Experimental stimulation by high-gradient magnetic fields provides a new approach to selectively manipulate the gravisensing system. The movement of corn, wheat, and potato starch grains in suspension was examined with videomicroscopy during parabolic flights that generated 20 to 25 s of weightlessness. During weightlessness, a magnetic gradient was generated by inserting a wedge into a uniform, external magnetic field that caused repulsion of starch grains. The resultant velocity of movement was compared with the velocity of sedimentation under 1 g conditions. The high-gradient magnetic fields repelled the starch grains and generated a force of at least 0.6 g. Different wedge shapes significantly affected starch velocity and directionality of movement. Magnetic gradients are able to move diamagnetic compounds under weightless or microgravity conditions and serve as directional stimulus during seed germination in low-gravity environments. Further work can determine whether gravity sensing is based on force or contact between amyloplasts and statocyte membrane system.

  20. On fracture in finite strain gradient plasticity

    DEFF Research Database (Denmark)

    Martínez Pañeda, Emilio; Niordson, Christian Frithiof

    2016-01-01

    In this work a general framework for damage and fracture assessment including the effect of strain gradients is provided. Both mechanism-based and phenomenological strain gradient plasticity (SGP) theories are implemented numerically using finite deformation theory and crack tip fields are invest......In this work a general framework for damage and fracture assessment including the effect of strain gradients is provided. Both mechanism-based and phenomenological strain gradient plasticity (SGP) theories are implemented numerically using finite deformation theory and crack tip fields...... are investigated. Differences and similarities between the two approaches within continuum SGP modeling are highlighted and discussed. Local strain hardening promoted by geometrically necessary dislocations (GNDs) in the vicinity of the crack leads to much higher stresses, relative to classical plasticity...... in the multiple parameter version of the phenomenological SGP theory. Since this also dominates the mechanics of indentation testing, results suggest that length parameters characteristic of mode I fracture should be inferred from nanoindentation....

  1. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  2. Role of the vertical pressure gradient in wave boundary layers

    DEFF Research Database (Denmark)

    Jensen, Karsten Lindegård; Sumer, B. Mutlu; Vittori, Giovanna

    2014-01-01

    By direct numerical simulation (DNS) of the flow in an oscillatory boundary layer, it is possible to obtain the pressure field. From the latter, the vertical pressure gradient is determined. Turbulent spots are detected by a criterion involving the vertical pressure gradient. The vertical pressure...... gradient is also treated as any other turbulence quantity like velocity fluctuations and statistical properties of the vertical pressure gradient are calculated from the DNS data. The presence of a vertical pressure gradient in the near bed region has significant implications for sediment transport....

  3. Near-surface temperature gradient in a coastal upwelling regime

    Science.gov (United States)

    Maske, H.; Ochoa, J.; Almeda-Jauregui, C. O.; Ruiz-de la Torre, M. C.; Cruz-López, R.; Villegas-Mendoza, J. R.

    2014-08-01

    In oceanography, a near homogeneous mixed layer extending from the surface to a seasonal thermocline is a common conceptual basis in physics, chemistry, and biology. In a coastal upwelling region 3 km off the coast in the Mexican Pacific, we measured vertical density gradients with a free-rising CTD and temperature gradients with thermographs at 1, 3, and 5 m depths logging every 5 min during more than a year. No significant salinity gradient was observed down to 10 m depth, and the CTD temperature and density gradients showed no pronounced discontinuity that would suggest a near-surface mixed layer. Thermographs generally logged decreasing temperature with depth with gradients higher than 0.2 K m-1 more than half of the time in the summer between 1 and 3 m, 3 and 5 m and in the winter between 1 and 3 m. Some negative temperature gradients were present and gradients were generally highly variable in time with high peaks lasting fractions of hours to hours. These temporal changes were too rapid to be explained by local heating or cooling. The pattern of positive and negative peaks might be explained by vertical stacks of water layers of different temperatures and different horizontal drift vectors. The observed near-surface gradient has implications for turbulent wind energy transfer, vertical exchange of dissolved and particulate water constituents, the interpretation of remotely sensed SST, and horizontal wind-induced transport.

  4. AGREEMENT BETWEEN THE WHITE MATTER CONNECTIVITY BASED ON THE TENSOR-BASED MORPHOMETRY AND THE VOLUMETRIC WHITE MATTER PARCELLATIONS BASED ON DIFFUSION TENSOR IMAGING.

    Science.gov (United States)

    Kim, Seung-Goo; Lee, Hyekyoung; Chung, Moo K; Hanson, Jamie L; Avants, Brian B; Gee, James C; Davidson, Richard J; Pollak, Seth D

    2012-01-01

    We are interested in investigating white matter connectivity using a novel computational framework that does not use diffusion tensor imaging (DTI) but only uses T1-weighted magnetic resonance imaging. The proposed method relies on correlating Jacobian determinants across different voxels based on the tensor-based morphometry (TBM) framework. In this paper, we show agreement between the TBM-based white matter connectivity and the DTI-based white matter atlas. As an application, altered white matter connectivity in a clinical population is determined.

  5. An Inexpensive Digital Gradient Controller for HPLC.

    Science.gov (United States)

    Brady, James E.; Carr, Peter W.

    1983-01-01

    Use of gradient elution techniques in high performance liquid chromatography (HPLC) is often essential for direct separation of complex mixtures. Since most commercial controllers have features that are of marginal value for instructional purposes, a low-cost controller capable of illustrating essential features of gradient elution was developed.…

  6. Scattering angle base filtering of the inversion gradients

    KAUST Repository

    Alkhalifah, Tariq Ali

    2014-01-01

    Full waveform inversion (FWI) requires a hierarchical approach based on the availability of low frequencies to maneuver the complex nonlinearity associated with the problem of velocity inversion. I develop a model gradient filter to help us access the parts of the gradient more suitable to combat this potential nonlinearity. The filter is based on representing the gradient in the time-lag normalized domain, in which low scattering angles of the gradient update are initially muted. The result are long-wavelength updates controlled by the ray component of the wavefield. In this case, even 10 Hz data can produce near zero wavelength updates suitable for a background correction of the model. Allowing smaller scattering angle to contribute provides higher resolution information to the model.

  7. Analysis of Gradient Waveform in Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    OU-YANG Shan-mei

    2017-12-01

    Full Text Available The accuracy of gradient pulse waveform affects image quality significantly in magnetic resonance imaging (MRI. Recording and analyzing the waveform of gradient pulse helps to make rapid and accurate diagnosis of spectrometer gradient hardware and/or pulse sequence. Using the virtual instrument software LabVIEW to control the high speed data acquisition card DAQ-2005, a multi-channel acquisition scheme was designed to collect the gradient outputs from a custom-made spectrometer. The collected waveforms were post-processed (i.e., histogram statistical analysis, data filtering and difference calculation to obtain feature points containing time and amplitude information. Experiments were carried out to validate the method, which is an auxiliary test method for the development of spectrometer and pulses sequence.

  8. Non-Conventional Thermodynamics and Models of Gradient Elasticity

    Directory of Open Access Journals (Sweden)

    Hans-Dieter Alber

    2018-03-01

    Full Text Available We consider material bodies exhibiting a response function for free energy, which depends on both the strain and its gradient. Toupin–Mindlin’s gradient elasticity is characterized by Cauchy stress tensors, which are given by space-like Euler–Lagrange derivative of the free energy with respect to the strain. The present paper aims at developing a first version of gradient elasticity of non-Toupin–Mindlin’s type, i.e., a theory employing Cauchy stress tensors, which are not necessarily expressed as Euler–Lagrange derivatives. This is accomplished in the framework of non-conventional thermodynamics. A one-dimensional boundary value problem is solved in detail in order to illustrate the differences of the present theory with Toupin–Mindlin’s gradient elasticity theory.

  9. End-inspiratory rebreathing reduces the end-tidal to arterial PCO2 gradient in mechanically ventilated pigs

    NARCIS (Netherlands)

    Fierstra, Jorn; Machina, Matthew; Battisti-Charbonney, Anne; Duffin, James; Fisher, Joseph Arnold; Minkovich, Leonid

    Noninvasive monitoring of the arterial partial pressures of CO2 (PaCO2) of critically ill patients by measuring their end-tidal partial pressures of CO2 (PetCO(2)) would be of great clinical value. However, the gradient between PetCO(2) and PaCO2 (Pet-aCO(2)) in such patients typically varies over a

  10. Estimation of the magnetic field gradient tensor using the Swarm constellation

    DEFF Research Database (Denmark)

    Kotsiaros, Stavros; Finlay, Chris; Olsen, Nils

    2014-01-01

    For the first time, part of the magnetic field gradient tensor is estimated in space by the Swarm mission. We investigate the possibility of a more complete estimation of the gradient tensor exploiting the Swarm constellation. The East-West gradients can be approximated by observations from...... deviations compared to conventional vector observations at almost all latitudes. Analytical and numerical analysis of the spectral properties of the gradient tensor shows that specific combinations of the East-West and North-South gradients have almost identical signal content to the radial gradient...

  11. Energy Transfer Using Gradient Index Metamaterial

    Directory of Open Access Journals (Sweden)

    Boopalan Ganapathy

    2018-01-01

    Full Text Available The gradient refractive index structure in this paper is used to increase the quantum of energy transfer. This is done by improving the directive gain of the pyramidal horn antenna at a frequency of 10 GHz. A three-dimensional array of closed square rings is placed in front of the horn antenna aperture to form a gradient refractive index structure. This structure increases the directive gain by 1.6 dB as compared to that of the conventional horn antenna. The structure nearly doubles the wireless power transfer quantum between the transmitter and the receiver when placed at both ends. The increase in the directivity is achieved by converting the spherical wave emanating from the horn to a plane wave once it passes through the structure. This transformation is realized by the gradient refractive index structure being placed perpendicular to the direction of propagation. The gradient refractive index is constructed by changing the dimensions of a closed square ring placed in the unit cell of the array. The change in the refractive index gives rise to an improvement of the half power beam width and side lobe level compared to that of the normal horn. The design and simulation were done using CST Studio software.

  12. Sound beam manipulation based on temperature gradients

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Feng [Key Laboratory of Modern Acoustics, Institute of Acoustics and School of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China); School of Physics & Electronic Engineering, Changshu Institute of Technology, Changshu 215500 (China); Quan, Li; Liu, Xiaozhou, E-mail: xzliu@nju.edu.cn; Gong, Xiufen [Key Laboratory of Modern Acoustics, Institute of Acoustics and School of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China)

    2015-10-28

    Previous research with temperature gradients has shown the feasibility of controlling airborne sound propagation. Here, we present a temperature gradients based airborne sound manipulation schemes: a cylindrical acoustic omnidirectional absorber (AOA). The proposed AOA has high absorption performance which can almost completely absorb the incident wave. Geometric acoustics is used to obtain the refractive index distributions with different radii, which is then utilized to deduce the desired temperature gradients. Since resonant units are not applied in the scheme, its working bandwidth is expected to be broadband. The scheme is temperature-tuned and easy to realize, which is of potential interest to fields such as noise control or acoustic cloaking.

  13. Gradients estimation from random points with volumetric tensor in turbulence

    Science.gov (United States)

    Watanabe, Tomoaki; Nagata, Koji

    2017-12-01

    We present an estimation method of fully-resolved/coarse-grained gradients from randomly distributed points in turbulence. The method is based on a linear approximation of spatial gradients expressed with the volumetric tensor, which is a 3 × 3 matrix determined by a geometric distribution of the points. The coarse grained gradient can be considered as a low pass filtered gradient, whose cutoff is estimated with the eigenvalues of the volumetric tensor. The present method, the volumetric tensor approximation, is tested for velocity and passive scalar gradients in incompressible planar jet and mixing layer. Comparison with a finite difference approximation on a Cartesian grid shows that the volumetric tensor approximation computes the coarse grained gradients fairly well at a moderate computational cost under various conditions of spatial distributions of points. We also show that imposing the solenoidal condition improves the accuracy of the present method for solenoidal vectors, such as a velocity vector in incompressible flows, especially when the number of the points is not large. The volumetric tensor approximation with 4 points poorly estimates the gradient because of anisotropic distribution of the points. Increasing the number of points from 4 significantly improves the accuracy. Although the coarse grained gradient changes with the cutoff length, the volumetric tensor approximation yields the coarse grained gradient whose magnitude is close to the one obtained by the finite difference. We also show that the velocity gradient estimated with the present method well captures the turbulence characteristics such as local flow topology, amplification of enstrophy and strain, and energy transfer across scales.

  14. Influence of permittivity on gradient force exerted on Mie spheres.

    Science.gov (United States)

    Chen, Jun; Li, Kaikai; Li, Xiao

    2018-04-01

    In optical trapping, whether a particle could be stably trapped into the focus region greatly depends on the strength of the gradient force. Individual theoretical study on gradient force exerted on a Mie particle is rare because the mathematical separation of the gradient force and the scattering force in the Mie regime is difficult. Based on the recent forces separation work by Du et al. [Sci. Rep.7, 18042 (2017)SRCEC32045-232210.1038/s41598-017-17874-1], we investigate the influence of permittivity (an important macroscopic physical quantity) on the gradient force exerted on a Mie particle by cooperating numerical calculation using fast Fourier transform and analytical analysis using multipole expansion. It is revealed that gradient forces exerted on small spheres are mainly determined by the electric dipole moment except for certain permittivity with which the real part of polarizability of the electric dipole approaches zero, and gradient forces exerted on larger spheres are complex because of the superposition of the multipole moments. The classification of permittivity corresponding to different varying tendencies of gradient forces exerted on small spheres or larger Mie particles are illustrated. Absorption of particles favors the trapping of small spheres by gradient force, while it is bad for the trapping of larger particles. Moreover, the absolute values of the maximal gradient forces exerted on larger Mie particles decline greatly versus the varied imaginary part of permittivity. This work provides elaborate investigation on the different varying tendencies of gradient forces versus permittivity, which favors more accurate and free optical trapping.

  15. Color Gradients Within Globular Clusters: Restricted Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Young-Jong Sohn

    1997-06-01

    Full Text Available The results of a restricted numerical simulation for the color gradients within globular clusters have been presented. The standard luminosity function of M3 and Salpeter's initial mass functions were used to generate model clusters as a fundamental population. Color gradients with the sample clusters for both King and power law cusp models of surface brightness distributions are discussed in the case of using the standard luminosity function. The dependence of color gradients on several parameters for the simulations with Salpeter's initial mass functions, such as slope of initial mass functions, cluster ages, metallicities, concentration parameters of King model, and slopes of power law, are also discussed. No significant radial color gradients are shown to the sample clusters which are regenerated by a random number generation technique with various parameters in both of King and power law cusp models of surface brightness distributions. Dynamical mass segregation and stellar evolution of horizontal branch stars and blue stragglers should be included for the general case of model simulations to show the observed radial color gradients within globular clusters.

  16. Individual- and community-level social gradients of edentulousness.

    Science.gov (United States)

    Ito, Kanade; Aida, Jun; Yamamoto, Tatsuo; Ohtsuka, Rika; Nakade, Miyo; Suzuki, Kayo; Kondo, Katsunori; Osaka, Ken

    2015-03-11

    Community-level factors as well as individual-level factors affect individual health. To date, no studies have examined the association between community-level social gradient and edentulousness. The aim of this study was to investigate individual- and community-level social inequalities in edentulousness and to determine any explanatory factors in this association. We analyzed the data from the Japan Gerontological Evaluation Study (JAGES). In 2010-2012, 112,123 subjects aged 65 or older responded to the questionnaire survey (response rate = 66.3%). Multilevel logistic regression analysis was applied to determine the association between community-level income and edentulousness after accounting for individual-level income and demographic covariates. Then, we estimated the probability of edentulousness by individual- and community-level incomes after adjusted for covariates. Of 79,563 valid participants, the prevalence of edentulousness among 39,550 men (49.7%) and 40,013 women (50.3%) were both 13.8%. Living in communities with higher mean incomes and having higher individual-level incomes were significantly associated with a lower risk of edentulousness (odds ratios [ORs] by 10,000 USD increments were 0.37 (95% confidence interval [CI] [0.22-0.63]) for community-level and 0.85 (95% CI [0.84-0.86]) for individual-level income). Individual- and community-level social factors, including density of dental clinics, partially explained the social gradients. However, in the fully adjusted model, both community- and individual-level social gradients of edentulousness remained significant (ORs = 0.43 (95% CI [0.27-0.67]) and 0.90 (95% CI [0.88-0.91]), respectively). One standard deviation changes in community- and individual-level incomes were associated with 0.78 and 0.84 times lower odds of edentulousness, respectively. In addition, compared to men, women living in communities with higher average incomes had a significantly lower risk of edentulousness (p-value for

  17. Aortic-Brachial Pulse Wave Velocity Ratio: A Measure of Arterial Stiffness Gradient Not Affected by Mean Arterial Pressure.

    Science.gov (United States)

    Fortier, Catherine; Desjardins, Marie-Pier; Agharazii, Mohsen

    2018-03-01

    Aortic stiffness, measured by carotid-femoral pulse wave velocity (cf-PWV), is used for the prediction of cardiovascular risk. This mini-review describes the nonlinear relationship between cf-PWV and operational blood pressure, presents the proposed methods to adjust for this relationship, and discusses a potential place for aortic-brachial PWV ratio (a measure of arterial stiffness gradient) as a blood pressure-independent measure of vascular aging. PWV is inherently dependent on the operational blood pressure. In cross-sectional studies, PWV adjustment for mean arterial pressure (MAP) is preferred, but still remains a nonoptimal approach, as the relationship between PWV and blood pressure is nonlinear and varies considerably among individuals due to heterogeneity in genetic background, vascular tone, and vascular remodeling. Extrapolations from the blood pressure-independent stiffness parameter β (β 0 ) have led to the creation of stiffness index β, which can be used for local stiffness. A similar approach has been used for cardio-ankle PWV to generate a blood pressure-independent cardio-ankle vascular index (CAVI). It was recently demonstrated that stiffness index β and CAVI remain slightly blood pressure-dependent, and a more appropriate formula has been proposed to make the proper adjustments. On the other hand, the negative impact of aortic stiffness on clinical outcomes is thought to be mediated through attenuation or reversal of the arterial stiffness gradient, which can also be influenced by a reduction in peripheral medium-sized muscular arteries in conditions that predispose to accelerate vascular aging. Arterial stiffness gradient, assessed by aortic-brachial PWV ratio, is emerging to be at least as good as cf-PWV for risk prediction, but has the advantage of not being affected by operating MAP. The negative impacts of aortic stiffness on clinical outcomes are proposed to be mediated through attenuation or reversal of arterial stiffness gradient

  18. Characterization of a texture gradient in tantalum plate

    International Nuclear Information System (INIS)

    Wright, S.I.; Gray, G.T. III.

    1994-01-01

    Clark et al. have shown that significant texture gradients can be produced in rolled tantalum plate and that the strength of the gradient is dependent on the processing path. Texture gradients are often ignored because they are time consuming to characterize and add significant complexity to materials modeling. The variation in texture through the thickness of rolled materials is most commonly measured by sectioning samples to different depths through the thickness of the plate and then measuring the texture from these section planes by X-ray diffraction. A new technique based on automatic indexing of electron backscatter diffraction patterns in the scanning electron microscope enables spatially specific orientations to be measured in a practical manner. This technique allows spatial variations in texture to be measured directly enabling gradients in texture to be investigated in more detail than previously possible. This data can be used directly in coupled finite-element/polycrystal-plasticity models to simulate the effects of variations in texture on the plastic behavior of polycrystals. This work examines the variation in texture through the thickness of a tantalum plate and its resultant effect on the compressive deformation of samples prepared from the plate. The characterization of the texture gradient using the automatic point-by-point measurement technique mentioned above is described in detail. The effect of the gradient on the plastic response of through-thickness compression tests is also discussed

  19. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  20. Ablation of hypertrophic septum using radiofrequency energy: an alternative for gradient reduction in patient with hypertrophic obstructive cardiomyopathy?

    Science.gov (United States)

    Riedlbauchová, Lucie; Janoušek, Jan; Veselka, Josef

    2013-06-01

    Alcohol septal ablation and surgical myectomy represent accepted therapeutic options for treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy. Long-term experience with radiofrequency ablation of arrhythmogenic substrates raised a question if this technique might be effective for left ventricular outflow tract (LVOT) gradient reduction. We report on a 63-year-old patient with recurrence of symptoms 1 year after alcohol septal ablation (ASA) leading originally to a significant reduction of both symptoms and gradient. Due to a new increase of gradient in the LVOT up to 200 mm Hg with corresponding worsening of symptoms and due to refusal of surgical myectomy by the patient, endocardial radiofrequency ablation of the septal hypertrophy (ERASH) was indicated. Radiofrequency ablation was performed in the LVOT using irrigated-tip ablation catheter; the target site was identified using intracardiac echocardiography and electroanatomical CARTO mapping. ERASH caused an immediate gradient reduction due to hypokinesis of the ablated septum. At 2-month follow-up exam, significant clinical improvement was observed, together with persistent gradient reduction assessed with Doppler echocardiography. Echocardiography and magnetic resonance revealed persistent septal hypokinesis and slight thinning of the ablated region. Septal ablation using radiofrequency energy may be a promising alternative or adjunct to the treatment of hypertrophic obstructive cardiomyopathy. Intracardiac echocardiography and electroanatomical CARTO mapping enable exact lesion placement and preservation of atrioventricular conduction.

  1. Characterizing Intraorbital Optic Nerve Changes on Diffusion Tensor Imaging in Thyroid Eye Disease Before Dysthyroid Optic Neuropathy.

    Science.gov (United States)

    Lee, Hwa; Lee, Young Hen; Suh, Sang-Il; Jeong, Eun-Kee; Baek, Sehyun; Seo, Hyung Suk

    The aim of this study was to determine whether the optic nerve is affected by thyroid eye disease (TED) before the development of dysthyroid optic neuropathy with diffusion-tensor imaging (DTI). Twenty TED patients and 20 controls were included. The mean, axial, and radial diffusivities and fractional anisotropy (FA) value were measured at the optic nerves in DTI. Extraocular muscle diameters were measured on computed tomography. The diffusivities and FA of the optic nerves were compared between TED and controls and between active and inactive stages of TED. The correlations between these DTI parameters and the clinical features were determined. The mean, axial, and radial diffusivities were lower in TED compared with the controls (P optic nerve before dysthyroid optic neuropathy in TED. The FA, in particular, reflected TED activity and severity.

  2. Ultimate gradient in solid-state accelerators

    International Nuclear Information System (INIS)

    Whittum, D.H.

    1998-08-01

    The authors recall the motivation for research in high-gradient acceleration and the problems posed by a compact collider. They summarize the phenomena known to appear in operation of a solid-state structure with large fields, and research relevant to the question of the ultimate gradient. They take note of new concepts, and examine one in detail, a miniature particle accelerator based on an active millimeter-wave circuit and parallel particle beams

  3. Fracture gradient: a new methodology that allows for more safety and economy; Gradiente de fratura: nova metodologia proporciona seguranca e economia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Helio M.R. dos [PETROBRAS, Rio de Janeiro (Brazil). Centro de Pesquisas. Setor de Tecnologia de Perfuracao; Foutoura, Sergio A.B. da [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil)

    1990-12-31

    The purpose of this paper is to show the influence of in-situ stresses and well geometry (direction and inclinational) on the fracture gradient. The results that are presented, obtained through computer simulation using an analytical model of the stresses around the well, show that in some cases it may be very dangerous to use fracture gradient data from vertical wells when dealing with non vertical wells. Likewise, it may also be unsafe to use results from absorption tests as the fracture gradient for the complete phase. The paper also indicates that, depending on the in-situ stresses and on the geometry of the well, the fracture gradient of a non-vertical well may be larger or smaller than that of vertical wells. Another aspects emphasized is that, through the use of more accurate calculations of the fracture gradient, it is possible to obtain great cost reduction, due to the fact that the casing strings will be designed in a more appropriate manner. (author) 12 refs., 4 figs.

  4. Conjugation of gold nanoparticles and recombinant human endostatin modulates vascular normalization via interruption of anterior gradient 2-mediated angiogenesis.

    Science.gov (United States)

    Pan, Fan; Yang, Wende; Li, Wei; Yang, Xiao-Yan; Liu, Shuhao; Li, Xin; Zhao, Xiaoxu; Ding, Hui; Qin, Li; Pan, Yunlong

    2017-07-01

    Several studies have revealed the potential of normalizing tumor vessels in anti-angiogenic treatment. Recombinant human endostatin is an anti-angiogenic agent which has been applied in clinical tumor treatment. Our previous research indicated that gold nanoparticles could be a nanoparticle carrier for recombinant human endostatin delivery. The recombinant human endostatin-gold nanoparticle conjugates normalized vessels, which improved chemotherapy. However, the mechanism of recombinant human endostatin-gold nanoparticle-induced vascular normalization has not been explored. Anterior gradient 2 has been reported to be over-expressed in many malignant tumors and involved in tumor angiogenesis. To date, the precise efficacy of recombinant human endostatin-gold nanoparticles on anterior gradient 2-mediated angiogenesis or anterior gradient 2-related signaling cohort remained unknown. In this study, we aimed to explore whether recombinant human endostatin-gold nanoparticles could normalize vessels in metastatic colorectal cancer xenografts, and we further elucidated whether recombinant human endostatin-gold nanoparticles could interrupt anterior gradient 2-induced angiogenesis. In vivo, it was indicated that recombinant human endostatin-gold nanoparticles increased pericyte expression while inhibit vascular endothelial growth factor receptor 2 and anterior gradient 2 expression in metastatic colorectal cancer xenografts. In vitro, we uncovered that recombinant human endostatin-gold nanoparticles reduced cell migration and tube formation induced by anterior gradient 2 in human umbilical vein endothelial cells. Treatment with recombinant human endostatin-gold nanoparticles attenuated anterior gradient 2-mediated activation of MMP2, cMyc, VE-cadherin, phosphorylation of p38, and extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) in human umbilical vein endothelial cells. Our findings demonstrated recombinant human endostatin-gold nanoparticles might normalize

  5. Spatial Resolution Effect on Forest Road Gradient Calculation and Erosion Modelling

    Science.gov (United States)

    Cao, L.; Elliot, W.

    2017-12-01

    Road erosion is one of the main sediment sources in a forest watershed and should be properly evaluated. With the help of GIS technology, road topography can be determined and soil loss can be predicted at a watershed scale. As a vector geographical feature, the road gradient should be calculated following road direction rather than hillslope direction. This calculation might be difficult with a coarse (30-m) DEM which only provides the underlying topography information. This study was designed to explore the effect of road segmentation and DEM resolution on the road gradient calculation and erosion prediction at a watershed scale. The Water Erosion Prediction Project (WEPP) model was run on road segments of 9 lengths ranging from 40m to 200m. Road gradient was calculated from three DEM data sets: 1m LiDAR, and 10m and 30m USGS DEMs. The 1m LiDAR DEM calculated gradients were very close to the field observed road gradients, so we assumed the 1m LiDAR DEM predicted the true road gradient. The results revealed that longer road segments skipped detail topographical undulations and resulted in lower road gradients. Coarser DEMs computed steeper road gradients as larger grid cells covered more adjacent areas outside road resulting in larger elevation differences. Field surveyed results also revealed that coarser DEM might result in more gradient deviation in a curved road segment when it passes through a convex or concave slope. As road segment length increased, the gradient difference between three DEMs was reduced. There were no significant differences between road gradients of different segment lengths and DEM resolution when segments were longer than 100m. For long segments, the 10m DEM calculated road gradient was similar to the 1m LiDAR gradient. When evaluating the effects of road segment length, the predicted erosion rate decreased with increasing length when road gradient was less than 3%. In cases where the road gradients exceed 3% and rill erosion dominates

  6. Vertebrate pressure-gradient receivers

    DEFF Research Database (Denmark)

    Christensen-Dalsgaard, Jakob

    2011-01-01

    The eardrums of all terrestrial vertebrates (tetrapods) are connected through Eustachian tubes or interaural canals. In some of the animals, these connections create pressure-gradient directionality, an enhanced directionality by interaction of sound arriving at both sides of the eardrum and stro......The eardrums of all terrestrial vertebrates (tetrapods) are connected through Eustachian tubes or interaural canals. In some of the animals, these connections create pressure-gradient directionality, an enhanced directionality by interaction of sound arriving at both sides of the eardrum....... Recent vertebrates form a continuum from perfect interaural transmission (0 dB in a certain frequency band) and pronounced eardrum directionality (30-40 dB) in the lizards, over somewhat attenuated transmission and limited directionality in birds and frogs, to the strongly attenuated interaural...

  7. Signal restoration for NMR imaging using time-dependent gradients

    International Nuclear Information System (INIS)

    Frahm, J.; Haenicke, W.

    1984-01-01

    NMR imaging experiments that employ linear but time-dependent gradients for encoding spatial information in the time-domain signals result in distorted images when treated with conventional image reconstruction techniques. It is shown here that the phase and amplitude distortions can be entirely removed if the timeshape of the gradient is known. The method proposed is of great theoretical and experimental simplicity. It consists of a retransformation of the measured time-domain signal and corresponds to synchronisation of the signal sampling with the time-development of the gradient field strength. The procedure complements other treatments of periodically oscillating gradients in NMR imaging. (author)

  8. Destabilization of drift waves due to nonuniform density gradient

    International Nuclear Information System (INIS)

    Hirose, A.; Ishihara, O.

    1985-01-01

    It is shown that the conventional mode differential equation for low frequency electrostatic waves in a tokamak does not contain full ion dynamics. Both electrons and ions contribute to the ballooning term, which is subject to finite ion Larmor radius effects. Also, both fluid ion approximation and kinetic ion model yield the same correction. Reexamined are the density gradient universal mode and ion temperature gradient instability employing the lowest order Pearlstein-Berk type radial eigenfunctions. No unstable, bounded, energy outgoing eigenfunctions have been found. In particular, a large ion temperature gradient (eta/sub i/) tends to further stabilize the temperature gradient driven mode

  9. Formation of actin networks in microfluidic concentration gradients

    Directory of Open Access Journals (Sweden)

    Natalja eStrelnikova

    2016-05-01

    Full Text Available The physical properties of cytoskeletal networks are contributors in a number of mechanical responses of cells including cellular deformation and locomotion, and are crucial for the proper action of living cells. Local chemical gradients modulate cytoskeletal functionality including the interactions of the cytoskeleton with other cellular components. Actin is a major constituent of the cytoskeleton. Introducing a microfluidic-based platform, we explored the impact of concentration gradients on the formation and structural properties of actin networks. Microfluidics-controlled flow-free steady state experimental conditions allow for the generation of chemical gradients of different profiles, such as linear or step-like. We discovered specific features of actin networks emerging in defined gradients. In particular, we analyzed the effects of spatial conditions on network properties, bending rigidities of network links, and the network elasticity.

  10. Spiral Gradient Coil Design for Use in Cylindrical MRI Systems.

    Science.gov (United States)

    Wang, Yaohui; Xin, Xuegang; Liu, Feng; Crozier, Stuart

    2018-04-01

    In magnetic resonance imaging, the stream function based method is commonly used in the design of gradient coils. However, this method can be prone to errors associated with the discretization of continuous current density and wire connections. In this paper, we propose a novel gradient coil design scheme that works directly in the wire space, avoiding the system errors that may appear in the stream function approaches. Specifically, the gradient coil pattern is described with dedicated spiral functions adjusted to allow the coil to produce the required field gradients in the imaging area, minimal stray field, and other engineering terms. The performance of a designed spiral gradient coil was compared with its stream-function counterpart. The numerical evaluation shows that when compared with the conventional solution, the inductance and resistance was reduced by 20.9 and 10.5%, respectively. The overall coil performance (evaluated by the figure of merit (FoM)) was improved up to 26.5% for the x -gradient coil design; for the z-gradient coil design, the inductance and resistance were reduced by 15.1 and 6.7% respectively, and the FoM was increased by 17.7%. In addition, by directly controlling the wire distributions, the spiral gradient coil design was much sparser than conventional coils.

  11. Color Gradient in the King Type Globular Cluster NGC 7089

    Directory of Open Access Journals (Sweden)

    Young-Jong Sohn

    1999-12-01

    Full Text Available We use BV CCD images to investigate the reality of the color gradient within a King type globular cluster NGC 7089. Surface photometry shows that there is a strong radial color gradient in the central region of the cluster in the sense of bluer center with the amplitude of -0.39 +/- 0.07 mag/arcsec2 in (B - V. In the outer region of the cluster, however, the radial color gradient shows a reverse case, i.e., redder toward the center. (B - V color profile which was derived from resolved stars in VGC 7089 field also shows a significant color gradient in the central region of the clusters, indicating that lights from the combination of red giant stars and blue horizontal branch stars cause the radial color gradient. Color gradient of the outer region of NGC 7089 may be due to the unresolved background of the cluster. Similar color gradients in the central area of clusters have been previously observed exserved exclusively in highly concentrated systems classified as post core collapse clusters. We caution, however, to confirm the reality of the color gradient from resolved stars, we need more accurate imaging data of the cluster with exceptional seeing condition because the effect of completeness correlates with local density of stars.

  12. Review of new shapes for higher gradients

    International Nuclear Information System (INIS)

    Geng, R.L.

    2006-01-01

    High-gradient superconducting RF (SRF) cavities are needed for energy frontier superconducting accelerators. Progress has been made over the past decades and the accelerating gradient E acc has been increased from a few MV/m to ∼42 MV/m in SRF niobium cavities. The corresponding peak RF magnetic field H pk on the niobium cavity surface is approaching the intrinsic RF critical magnetic field H crit,RF , a hard physical limit at which superconductivity breaks down. Pushing the gradient envelope further by adopting new cavity shapes with a lower ratio of H pk /E acc has been recently proposed. For a reduced H pk /E acc , a higher ultimate E acc is sustained when H pk finally strikes H crit,RF . The new cavity geometry include the re-entrant shape conceived at Cornell University and the so-called 'Low-loss' shape proposed by a DESY/JLAB/KEK collaboration. Experimental work is being pursued at Cornell, KEK and JLAB. Results of single-cell cavities are encouraging. A record gradient of 47 MV/m was first demonstrated in a 1.3 GHz re-entrant niobium cavity at Cornell University. At the time of writing, a new record of 52 MV/m has been realized with another 1.3 GHz re-entrant cavity, designed and built at Cornell and processed and tested at KEK. Single-cell low-loss cavities have reached equally high gradients in the range of 45-51 MV/m at KEK and JLAB. Owing to their higher gradient potential and the encouraging single-cell cavity results, the new cavity shapes are becoming attractive for their possible use in the international linear collider (ILC). Experimental work on multi-cell niobium cavities of new shapes is currently under active exploration

  13. Review of new shapes for higher gradients

    Science.gov (United States)

    Geng, R. L.

    2006-07-01

    High-gradient superconducting RF (SRF) cavities are needed for energy frontier superconducting accelerators. Progress has been made over the past decades and the accelerating gradient Eacc has been increased from a few MV/m to ∼42 MV/m in SRF niobium cavities. The corresponding peak RF magnetic field Hpk on the niobium cavity surface is approaching the intrinsic RF critical magnetic field Hcrit,RF, a hard physical limit at which superconductivity breaks down. Pushing the gradient envelope further by adopting new cavity shapes with a lower ratio of Hpk/ Eacc has been recently proposed. For a reduced Hpk/ Eacc, a higher ultimate Eacc is sustained when Hpk finally strikes Hcrit,RF. The new cavity geometry include the re-entrant shape conceived at Cornell University and the so-called “Low-loss” shape proposed by a DESY/JLAB/KEK collaboration. Experimental work is being pursued at Cornell, KEK and JLAB. Results of single-cell cavities are encouraging. A record gradient of 47 MV/m was first demonstrated in a 1.3 GHz re-entrant niobium cavity at Cornell University. At the time of writing, a new record of 52 MV/m has been realized with another 1.3 GHz re-entrant cavity, designed and built at Cornell and processed and tested at KEK. Single-cell low-loss cavities have reached equally high gradients in the range of 45-51 MV/m at KEK and JLAB. Owing to their higher gradient potential and the encouraging single-cell cavity results, the new cavity shapes are becoming attractive for their possible use in the international linear collider (ILC). Experimental work on multi-cell niobium cavities of new shapes is currently under active exploration.

  14. METALLICITY GRADIENTS OF THICK DISK DWARF STARS

    Energy Technology Data Exchange (ETDEWEB)

    Carrell, Kenneth; Chen Yuqin; Zhao Gang, E-mail: carrell@nao.cas.cn [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2012-12-01

    We examine the metallicity distribution of the Galactic thick disk using F, G, and K dwarf stars selected from the Sloan Digital Sky Survey, Data Release 8. Using the large sample of dwarf stars with proper motions and spectroscopically determined stellar parameters, metallicity gradients in the radial direction for various heights above the Galactic plane and in the vertical direction for various radial distances from the Galaxy center have been found. In particular, we find a vertical metallicity gradient of -0.113 {+-} 0.010 (-0.125 {+-} 0.008) dex kpc{sup -1} using an isochrone (photometric) distance determination in the range 1 kpc <|Z| < 3 kpc, which is the vertical height range most consistent with the thick disk of our Galaxy. In the radial direction, we find metallicity gradients between +0.02 and +0.03 dex kpc{sup -1} for bins in the vertical direction between 1 kpc <|Z| < 3 kpc. Both of these results agree with similar values determined from other populations of stars, but this is the first time a radial metallicity gradient for the thick disk has been found at these vertical heights. We are also able to separate thin and thick disk stars based on kinematic and spatial probabilities in the vertical height range where there is significant overlap of these two populations. This should aid further studies of the metallicity gradients of the disk for vertical heights lower than those studied here but above the solar neighborhood. Metallicity gradients in the thin and thick disks are important probes into possible formation scenarios for our Galaxy and a consistent picture is beginning to emerge from results using large spectroscopic surveys, such as the ones presented here.

  15. Increased flow sensitivity from gradient recalled echoes and short TRs

    International Nuclear Information System (INIS)

    Hearshen, D.O.; Froelich, J.W.; Wehrli, F.W.; Haggar, A.M.; Shimakawa, A.

    1986-01-01

    Time-of-flight effects from flow have been characterized in spin-echo images. ''Paradoxical'' enhancement and flow void are observed. Similar enhancement is seen on GRASS images. With no flow void and gradients existing throughout the volume, spins experiencing radio-frequency pulses will give rise to signals even for fast flow, providing a greater velocity sensitivity. GRASS images were obtained from a volunteer with a blood pressure cuff placed over the right thigh. With the cuff inflated, flow in the popliteal vein results in signal saturation. Increasing TR increases intensity in the popliteal vein relative to other vessels. This suggests a clinical role for the technique in assessment of slow flow

  16. Considerations of ion temperature gradient driven turbulence

    International Nuclear Information System (INIS)

    Cowley, S.C.; Kulsrud, R.M.

    1991-02-01

    The ion temperature gradient driven instability is considered in this paper. Physical pictures are presented to clarify the nature of the instability. The saturation of a single eddy is modeled by a simple nonlinear equation. We show that eddies which are elongated in the direction of the temperature gradient are the most unstable and have the highest saturation amplitudes. In a sheared magnetic field, such elongated eddies twist with the field lines. This structure is shown to be alternative to the usual Fourier mode picture in which the mode is localized around the surface where k parallel = 0. We show how these elongated twisting eddies, which are an integral part of the ''ballooning mode'' structure, could survive in a torus. The elongated eddies are shown to be unstable to secondary instabilities that are driven by the large gradients in the long eddy. We argue that this mechanism isotropizes ion temperature gradient turbulence. We further argue that the ''mixing length'' is set by this nonlinear process, not by a linear eigenmode width. 17 refs., 6 figs

  17. Joining of Tungsten Armor Using Functional Gradients

    International Nuclear Information System (INIS)

    John Scott O'Dell

    2006-01-01

    The joining of low thermal expansion armor materials such as tungsten to high thermal expansion heat sink materials has been a major problem in plasma facing component (PFC) development. Conventional planar bonding techniques have been unable to withstand the high thermal induced stresses resulting from fabrication and high heat flux testing. During this investigation, innovative functional gradient joints produced using vacuum plasma spray forming techniques have been developed for joining tungsten armor to copper alloy heat sinks. A model was developed to select the optimum gradient architecture. Based on the modeling effort, a 2mm copper rich gradient was selected. Vacuum plasma pray parameters and procedures were then developed to produce the functional gradient joint. Using these techniques, dual cooling channel, medium scale mockups (32mm wide x 400mm length) were produced with vacuum plasma spray formed tungsten armor. The thickness of the tungsten armor was up to 5mm thick. No evidence of debonding at the interface between the heat sink and the vacuum plasma sprayed material was observed.

  18. Manipulating the Gradient

    Science.gov (United States)

    Gaze, Eric C.

    2005-01-01

    We introduce a cooperative learning, group lab for a Calculus III course to facilitate comprehension of the gradient vector and directional derivative concepts. The lab is a hands-on experience allowing students to manipulate a tangent plane and empirically measure the effect of partial derivatives on the direction of optimal ascent. (Contains 7…

  19. Prediction of Outcome in Acute Lower Gastrointestinal Bleeding Using Gradient Boosting.

    Directory of Open Access Journals (Sweden)

    Lakshmana Ayaru

    Full Text Available There are no widely used models in clinical care to predict outcome in acute lower gastro-intestinal bleeding (ALGIB. If available these could help triage patients at presentation to appropriate levels of care/intervention and improve medical resource utilisation. We aimed to apply a state-of-the-art machine learning classifier, gradient boosting (GB, to predict outcome in ALGIB using non-endoscopic measurements as predictors.Non-endoscopic variables from patients with ALGIB attending the emergency departments of two teaching hospitals were analysed retrospectively for training/internal validation (n=170 and external validation (n=130 of the GB model. The performance of the GB algorithm in predicting recurrent bleeding, clinical intervention and severe bleeding was compared to a multiple logic regression (MLR model and two published MLR-based prediction algorithms (BLEED and Strate prediction rule.The GB algorithm had the best negative predictive values for the chosen outcomes (>88%. On internal validation the accuracy of the GB algorithm for predicting recurrent bleeding, therapeutic intervention and severe bleeding were (88%, 88% and 78% respectively and superior to the BLEED classification (64%, 68% and 63%, Strate prediction rule (78%, 78%, 67% and conventional MLR (74%, 74% 62%. On external validation the accuracy was similar to conventional MLR for recurrent bleeding (88% vs. 83% and therapeutic intervention (91% vs. 87% but superior for severe bleeding (83% vs. 71%.The gradient boosting algorithm accurately predicts outcome in patients with acute lower gastrointestinal bleeding and outperforms multiple logistic regression based models. These may be useful for risk stratification of patients on presentation to the emergency department.

  20. The social gradient in oral health: Is there a role for dental anxiety?

    Science.gov (United States)

    Bernabé, Eduardo; Humphris, Gerry; Freeman, Ruth

    2017-08-01

    To evaluate the contribution of dental anxiety to social gradients in different oral health outcomes and whether social gradients in oral health persist once dental anxiety is removed from the population examined. Data from 9035 British adults were analysed. Participants' socioeconomic position (SEP) was measured through education and household income. Dental anxiety was measured with the Modified Dental Anxiety Scale. Poor subjective oral health, oral impacts on quality of life and edentulism among all adults and the number of teeth, the number of decayed, missing and filled surfaces (DMFS) and sextants with pocketing among dentate adults were the oral health outcomes. The contribution of dental anxiety to absolute and relative social inequalities in each oral health outcome (measured with the Slope and Relative Index of Inequality [SII and RII], respectively) was estimated from regression models without and with adjustment for dental anxiety and quantified with the percentage attenuation. Interactions between each SEP indicator and dental anxiety were used to test what would happen if dental anxiety were removed from the whole population. The largest contribution of dental anxiety to explaining oral health inequalities was found for education gradients in perceived outcomes (11%-13%), but dental anxiety explained social gradients in edentulism. Among dentate adults, dental anxiety accounted for anxiety-free adults but were significant at higher levels of dental anxiety. Little support was found for the role of dental anxiety in explaining social inequalities in various perceived and clinical oral health measures. Oral health inequalities were found among both nondentally anxious and anxious participants. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Generating substrate bound functional chemokine gradients in vitro

    DEFF Research Database (Denmark)

    Hjortø, Gertrud Malene; Hansen, Morten; Larsen, Niels Bent

    2009-01-01

    Microcontact printing (mCP) is employed to generate discontinuous microscale gradients of active fractalkine, a chemokine expressed by endothelial cells near sites of inflammation where it is believed to form concentration gradients descending away from the inflamed area. In vivo, fractalkine...... active part of the molecules. Here, indirect mCP of a capture antibody recognizing a molecular tag on the target protein is successfully used to pattern tagged fractalkine in microscale gradient patterns. Fractalkine functions as an adhesion molecule for leukocytes. Cells expressing the fractalkine...

  2. Quasistatic nonlinear viscoelasticity and gradient flows

    OpenAIRE

    Ball, John M.; Şengül, Yasemin

    2014-01-01

    We consider the equation of motion for one-dimensional nonlinear viscoelasticity of strain-rate type under the assumption that the stored-energy function is λ-convex, which allows for solid phase transformations. We formulate this problem as a gradient flow, leading to existence and uniqueness of solutions. By approximating general initial data by those in which the deformation gradient takes only finitely many values, we show that under suitable hypotheses on the stored-energy function the d...

  3. Substrate curvature gradient drives rapid droplet motion.

    Science.gov (United States)

    Lv, Cunjing; Chen, Chao; Chuang, Yin-Chuan; Tseng, Fan-Gang; Yin, Yajun; Grey, Francois; Zheng, Quanshui

    2014-07-11

    Making small liquid droplets move spontaneously on solid surfaces is a key challenge in lab-on-chip and heat exchanger technologies. Here, we report that a substrate curvature gradient can accelerate micro- and nanodroplets to high speeds on both hydrophilic and hydrophobic substrates. Experiments for microscale water droplets on tapered surfaces show a maximum speed of 0.42  m/s, 2 orders of magnitude higher than with a wettability gradient. We show that the total free energy and driving force exerted on a droplet are determined by the substrate curvature and substrate curvature gradient, respectively. Using molecular dynamics simulations, we predict nanoscale droplets moving spontaneously at over 100  m/s on tapered surfaces.

  4. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    Science.gov (United States)

    Lasič, Samo; Lundell, Henrik; Topgaard, Daniel; Dyrby, Tim B

    2018-04-01

    To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). The effects of imaging gradients in FEXI were observed on yeast cells. To analyze the AXR bias, signal evolution was calculated by applying matrix exponential operators. A sharp threshold for the slice thickness was identified, below which the AXR is increasingly underestimated. The bias can be understood in terms of an extended low-pass diffusion filtering during the LS interval, which is more pronounced at lower exchange rates. For a total exchange rate constant larger than 1 s -1 , the AXR bias is expected to be negligible when slices thicker than 2.5 mm are used. In correlation experiments like FEXI, relying on LS with variable duration, imaging gradients may cause disrupting effects that cannot be easily mitigated and should be carefully considered for unbiased results. In typical clinical applications of FEXI, the imaging gradients are expected to cause a negligible AXR bias. However, the AXR bias may be significant in preclinical settings or whenever thin imaging slices are used. Magn Reson Med 79:2228-2235, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Diffusion tensor imaging of the cervical spinal cord in healthy adult population: normative values and measurement reproducibility at 3T MRI.

    Science.gov (United States)

    Brander, Antti; Koskinen, Eerika; Luoto, Teemu M; Hakulinen, Ullamari; Helminen, Mika; Savilahti, Sirpa; Ryymin, Pertti; Dastidar, Prasun; Ohman, Juha

    2014-05-01

    Compared to diffusion tensor imaging (DTI) of the brain, there is a paucity of reports addressing the applicability of DTI in the evaluation of the spinal cord. Most normative data of cervical spinal cord DTI consist of relatively small and arbitrarily collected populations. Comprehensive normative data are necessary for clinical decision-making. To establish normal values for cervical spinal cord DTI metrics with region of interest (ROI)- and fiber tractography (FT)-based measurements and to assess the reproducibility of both measurement methods. Forty healthy adults underwent cervical spinal cord 3T MRI. Sagittal and axial conventional T2 sequences and DTI in the axial plane were performed. Whole cord fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values were determined at different cervical levels from C2 to C7 using the ROI method. DTI metrics (FA, axial, and radial diffusivities based on eigenvalues λ1, λ2, and λ3, and ADC) of the lateral and posterior funicles were measured at C3 level. FA and ADC of the whole cord and the lateral and posterior funicles were also measured using quantitative tractography. Intra- and inter-observer variation of the measurement methods were assessed. Whole cord FA values decreased and ADC values increased in the rostral to caudal direction from C2 to C7. Between the individual white matter funicles no statistically significant difference for FA or ADC values was found. Both axial diffusivity and radial diffusivity of both lateral funicles differed significantly from those of the posterior funicle. Neither gender nor age correlated with any of the DTI metrics. Intra-observer variation of the measurements for whole cord FA and ADC showed almost perfect agreement with both ROI and tractography-based measurements. There was more variation in measurements of individual columns. Inter-observer agreement varied from moderate to strong for whole cord FA and ADC. Both ROI- and FT-based measurements are applicable

  6. The molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory: The DEC-RI-MP2 gradient

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, Dmytro; Kristensen, Kasper; Kjærgaard, Thomas [Department of Chemistry, qLeap Center for Theoretical Chemistry, University of Aarhus, DK-8000 Århus C (Denmark)

    2016-07-14

    We report an implementation of the molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory (DEC-RI-MP2). The new DEC-RI-MP2 gradient method combines the precision control as well as the linear-scaling and massively parallel features of the DEC scheme with efficient evaluations of the gradient contributions using the RI approximation. We further demonstrate that the DEC-RI-MP2 gradient method is capable of calculating molecular gradients for very large molecular systems. A test set of supramolecular complexes containing up to 158 atoms and 1960 contracted basis functions has been employed to demonstrate the general applicability of the DEC-RI-MP2 method and to analyze the errors of the DEC approximation. Moreover, the test set contains molecules of complicated electronic structures and is thus deliberately chosen to stress test the DEC-RI-MP2 gradient implementation. Additionally, as a showcase example the full molecular gradient for insulin (787 atoms and 7604 contracted basis functions) has been evaluated.

  7. The molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory: The DEC-RI-MP2 gradient

    International Nuclear Information System (INIS)

    Bykov, Dmytro; Kristensen, Kasper; Kjærgaard, Thomas

    2016-01-01

    We report an implementation of the molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory (DEC-RI-MP2). The new DEC-RI-MP2 gradient method combines the precision control as well as the linear-scaling and massively parallel features of the DEC scheme with efficient evaluations of the gradient contributions using the RI approximation. We further demonstrate that the DEC-RI-MP2 gradient method is capable of calculating molecular gradients for very large molecular systems. A test set of supramolecular complexes containing up to 158 atoms and 1960 contracted basis functions has been employed to demonstrate the general applicability of the DEC-RI-MP2 method and to analyze the errors of the DEC approximation. Moreover, the test set contains molecules of complicated electronic structures and is thus deliberately chosen to stress test the DEC-RI-MP2 gradient implementation. Additionally, as a showcase example the full molecular gradient for insulin (787 atoms and 7604 contracted basis functions) has been evaluated.

  8. Voxel-based analysis of the diffusion tensor

    International Nuclear Information System (INIS)

    Abe, Osamu; Takao, Hidemasa; Gonoi, Wataru; Sasaki, Hiroki; Murakami, Mizuho; Ohtomo, Kuni; Kabasawa, Hiroyuki; Kawaguchi, Hiroshi; Goto, Masami; Yamada, Haruyasu; Yamasue, Hidenori; Kasai, Kiyoto; Aoki, Shigeki

    2010-01-01

    Diffusion tensor imaging (DTI) has provided important insights into the neurobiological basis for normal development and aging and various disease processes in the central nervous system. The aim of this article is to review the current protocols for DTI acquisition and preprocessing and statistical testing for a voxelwise analysis of DTI, focused on statistical parametric mapping (SPM) and tract-based spatial statistics (TBSS). We tested the effects of distortion correction induced by gradient nonlinearity on fractional anisotropy (FA) maps or FA skeletons processed via two SPM-based methods (coregistration and FA template methods), or TBSS-based method, respectively. With two SPM-based methods, we found similar results in some points (e.g., significant FA elevation for uncorrected images in anterior-dominant white matter and for corrected images in bilateral middle cerebellar peduncles) and different results in other points (e.g., significantly larger FA for corrected images with coregistration method, but significantly smaller with FA template method in bilateral internal capsules, extending to corona radiata, and semioval centers). In contrast, there was no area with significant difference between uncorrected and corrected FA skeletons with TBSS-based method. The discrepancy among these results was not explained in full, but possible explanations were misregistration and smoothing for the SPM-based methods and insensitivity to FA changes outside the local centers of white matter bundles for TBSS-based method. (orig.)

  9. Modeling chemical gradients in sediments under losing and gaining flow conditions: The GRADIENT code

    Science.gov (United States)

    Boano, Fulvio; De Falco, Natalie; Arnon, Shai

    2018-02-01

    Interfaces between sediments and water bodies often represent biochemical hotspots for nutrient reactions and are characterized by steep concentration gradients of different reactive solutes. Vertical profiles of these concentrations are routinely collected to obtain information on nutrient dynamics, and simple codes have been developed to analyze these profiles and determine the magnitude and distribution of reaction rates within sediments. However, existing publicly available codes do not consider the potential contribution of water flow in the sediments to nutrient transport, and their applications to field sites with significant water-borne nutrient fluxes may lead to large errors in the estimated reaction rates. To fill this gap, the present work presents GRADIENT, a novel algorithm to evaluate distributions of reaction rates from observed concentration profiles. GRADIENT is a Matlab code that extends a previously published framework to include the role of nutrient advection, and provides robust estimates of reaction rates in sediments with significant water flow. This work discusses the theoretical basis of the method and shows its performance by comparing the results to a series of synthetic data and to laboratory experiments. The results clearly show that in systems with losing or gaining fluxes, the inclusion of such fluxes is critical for estimating local and overall reaction rates in sediments.

  10. Tight junction regulates epidermal calcium ion gradient and differentiation

    International Nuclear Information System (INIS)

    Kurasawa, Masumi; Maeda, Tetsuo; Oba, Ai; Yamamoto, Takuya; Sasaki, Hiroyuki

    2011-01-01

    Research highlights: → We disrupted epidermal tight junction barrier in reconstructed epidermis. → It altered Ca 2+ distribution and consequentially differentiation state as well. → Tight junction should affect epidermal homeostasis by maintaining Ca 2+ gradient. -- Abstract: It is well known that calcium ions (Ca 2+ ) induce keratinocyte differentiation. Ca 2+ distributes to form a vertical gradient that peaks at the stratum granulosum. It is thought that the stratum corneum (SC) forms the Ca 2+ gradient since it is considered the only permeability barrier in the skin. However, the epidermal tight junction (TJ) in the granulosum has recently been suggested to restrict molecular movement to assist the SC as a secondary barrier. The objective of this study was to clarify the contribution of the TJ to Ca 2+ gradient and epidermal differentiation in reconstructed human epidermis. When the epidermal TJ barrier was disrupted by sodium caprate treatment, Ca 2+ flux increased and the gradient changed in ion-capture cytochemistry images. Alterations of ultrastructures and proliferation/differentiation markers revealed that both hyperproliferation and precocious differentiation occurred regionally in the epidermis. These results suggest that the TJ plays a crucial role in maintaining epidermal homeostasis by controlling the Ca 2+ gradient.

  11. Precision bounds for gradient magnetometry with atomic ensembles

    Science.gov (United States)

    Apellaniz, Iagoba; Urizar-Lanz, Iñigo; Zimborás, Zoltán; Hyllus, Philipp; Tóth, Géza

    2018-05-01

    We study gradient magnetometry with an ensemble of atoms with arbitrary spin. We calculate precision bounds for estimating the gradient of the magnetic field based on the quantum Fisher information. For quantum states that are invariant under homogeneous magnetic fields, we need to measure a single observable to estimate the gradient. On the other hand, for states that are sensitive to homogeneous fields, a simultaneous measurement is needed, as the homogeneous field must also be estimated. We prove that for the cases studied in this paper, such a measurement is feasible. We present a method to calculate precision bounds for gradient estimation with a chain of atoms or with two spatially separated atomic ensembles. We also consider a single atomic ensemble with an arbitrary density profile, where the atoms cannot be addressed individually, and which is a very relevant case for experiments. Our model can take into account even correlations between particle positions. While in most of the discussion we consider an ensemble of localized particles that are classical with respect to their spatial degree of freedom, we also discuss the case of gradient metrology with a single Bose-Einstein condensate.

  12. Diffusion Tensor Imaging of Central Auditory Pathways in Patients with Sensorineural Hearing Loss: A Systematic Review.

    Science.gov (United States)

    Tarabichi, Osama; Kozin, Elliott D; Kanumuri, Vivek V; Barber, Samuel; Ghosh, Satra; Sitek, Kevin R; Reinshagen, Katherine; Herrmann, Barbara; Remenschneider, Aaron K; Lee, Daniel J

    2018-03-01

    Objective The radiologic evaluation of patients with hearing loss includes computed tomography and magnetic resonance imaging (MRI) to highlight temporal bone and cochlear nerve anatomy. The central auditory pathways are often not studied for routine clinical evaluation. Diffusion tensor imaging (DTI) is an emerging MRI-based modality that can reveal microstructural changes in white matter. In this systematic review, we summarize the value of DTI in the detection of structural changes of the central auditory pathways in patients with sensorineural hearing loss. Data Sources PubMed, Embase, and Cochrane. Review Methods We used the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement checklist for study design. All studies that included at least 1 sensorineural hearing loss patient with DTI outcome data were included. Results After inclusion and exclusion criteria were met, 20 articles were analyzed. Patients with bilateral hearing loss comprised 60.8% of all subjects. Patients with unilateral or progressive hearing loss and tinnitus made up the remaining studies. The auditory cortex and inferior colliculus (IC) were the most commonly studied regions using DTI, and most cases were found to have changes in diffusion metrics, such as fractional anisotropy, compared to normal hearing controls. Detectable changes in other auditory regions were reported, but there was a higher degree of variability. Conclusion White matter changes based on DTI metrics can be seen in patients with sensorineural hearing loss, but studies are few in number with modest sample sizes. Further standardization of DTI using a prospective study design with larger sample sizes is needed.

  13. Magnetic Resonance Neurography Visualizes Abnormalities in Sciatic and Tibial Nerves in Patients With Type 1 Diabetes and Neuropathy.

    Science.gov (United States)

    Vaeggemose, Michael; Pham, Mirko; Ringgaard, Steffen; Tankisi, Hatice; Ejskjaer, Niels; Heiland, Sabine; Poulsen, Per L; Andersen, Henning

    2017-07-01

    This study evaluates whether diffusion tensor imaging magnetic resonance neurography (DTI-MRN), T2 relaxation time, and proton spin density can detect and grade neuropathic abnormalities in patients with type 1 diabetes. Patients with type 1 diabetes ( n = 49) were included-11 with severe polyneuropathy (sDPN), 13 with mild polyneuropathy (mDPN), and 25 without polyneuropathy (nDPN)-along with 30 healthy control subjects (HCs). Clinical examinations, nerve conduction studies, and vibratory perception thresholds determined the presence and severity of DPN. DTI-MRN covered proximal (sciatic nerve) and distal (tibial nerve) nerve segments of the lower extremity. Fractional anisotropy (FA) and the apparent diffusion coefficient (ADC) were calculated, as were T2 relaxation time and proton spin density obtained from DTI-MRN. All magnetic resonance findings were related to the presence and severity of neuropathy. FA of the sciatic and tibial nerves was lowest in the sDPN group. Corresponding with this, proximal and distal ADCs were highest in patients with sDPN compared with patients with mDPN and nDPN, as well as the HCs. DTI-MRN correlated closely with the severity of neuropathy, demonstrating strong associations with sciatic and tibial nerve findings. Quantitative group differences in proton spin density were also significant, but less pronounced than those for DTI-MRN. In conclusion, DTI-MRN enables detection in peripheral nerves of abnormalities related to DPN, more so than proton spin density or T2 relaxation time. These abnormalities are likely to reflect pathology in sciatic and tibial nerve fibers. © 2017 by the American Diabetes Association.

  14. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    International Nuclear Information System (INIS)

    Ancora, G.; Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R.; Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G.; Tani, G.; Malucelli, E.

    2013-01-01

    MRI, proton magnetic resonance spectroscopy ( 1 H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on 1 H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and 1 H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both 1 H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of 1 H-MRS and DTI, which outperform conventional MRI. (orig.)

  15. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  16. Investigation of axial power gradients near a control rod tip

    International Nuclear Information System (INIS)

    Loberg, John; Osterlund, Michael; Bejmer, Klaes-Hakan; Blomgren, Jan; Kierkegaard, Jesper

    2011-01-01

    Highlights: → Pin power gradients near BWR control rod tips have been investigated. → A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. → Small nodes increases pin power gradients; standard nodes underestimates gradients. → The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, ∼15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  17. Flow-related Right Ventricular - Pulmonary Arterial Pressure Gradients during Exercise.

    Science.gov (United States)

    Wright, Stephen P; Opotowsky, Alexander R; Buchan, Tayler A; Esfandiari, Sam; Granton, John T; Goodman, Jack M; Mak, Susanna

    2018-06-06

    The assumption of equivalence between right ventricular and pulmonary arterial systolic pressure is fundamental to several assessments of right ventricular or pulmonary vascular hemodynamic function. Our aims were to 1) determine whether systolic pressure gradients develop across the right ventricular outflow tract in healthy adults during exercise, 2) examine the potential correlates of such gradients, and 3) consider the effect of such gradients on calculated indices of right ventricular function. Healthy untrained and endurance-trained adult volunteers were studied using right-heart catheterization at rest and during submaximal cycle ergometry. Right ventricular and pulmonary artery pressures were simultaneously transduced, and cardiac output was determined by thermodilution. Systolic pressures, peak and mean gradients, and indices of chamber, vascular, and valve function were analyzed offline. Summary data are reported as mean ± standard deviation or median [interquartile range]. No significant right ventricular outflow tract gradients were observed at rest (mean gradient = 4 [3-5] mmHg), and calculated effective orifice area was 3.6±1.0 cm2. Right ventricular systolic pressure increases during exercise were greater than that of pulmonary artery systolic pressure. Accordingly, mean gradients developed during light exercise (8 [7-9] mmHg) and increased during moderate exercise (12 [9-14] mmHg, p < 0.001). The magnitude of the mean gradient was linearly related to cardiac output (r2 = 0.70, p < 0.001). In healthy adults without pulmonic stenosis, systolic pressure gradients develop during exercise, and the magnitude is related to blood flow rate.

  18. Proton gradients and proton-dependent transport processes in the chloroplast

    Directory of Open Access Journals (Sweden)

    Ricarda eHöhner

    2016-02-01

    Full Text Available Proton gradients are fundamental to chloroplast function. Across thylakoid membranes, the light induced proton gradient is essential for ATP synthesis. As a result of proton pumping into the thylakoid lumen, an alkaline stromal pH develops, which is required for full activation of pH-dependent Calvin Benson cycle enzymes. This implies that a pH gradient between the cytosol (pH 7 and the stroma (pH 8 is established upon illumination. To maintain this pH gradient chloroplasts actively extrude protons. More than 30 years ago it was already established that these proton fluxes are electrically counterbalanced by Mg2+, K+ or Cl- fluxes, but only recently the first transport systems that regulate the pH gradient were identified. Notably several (Na+,K+/H+ antiporter systems where identified, that play a role in pH gradient regulation, ion homeostasis, osmoregulation, or coupling of secondary active transport. The established pH gradients are important to drive uptake of essential ions and solutes, but not many transporters involved have been identified to date. In this mini review we summarize the current status in the field and the open questions that need to be addressed in order to understand how pH gradients are maintained, how this is interconnected with other transport processes and what this means for chloroplast function.

  19. An extended discrete gradient formula for oscillatory Hamiltonian systems

    International Nuclear Information System (INIS)

    Liu Kai; Shi Wei; Wu Xinyuan

    2013-01-01

    In this paper, incorporating the idea of the discrete gradient method into the extended Runge–Kutta–Nyström integrator, we derive and analyze an extended discrete gradient formula for the oscillatory Hamiltonian system with the Hamiltonian H(p,q)= 1/2 p T p+ 1/2 q T Mq+U(q), where q:R→R d represents generalized positions, p:R→R d represents generalized momenta and M is an element of R dxd is a symmetric and positive semi-definite matrix. The solution of this system is a nonlinear oscillator. Basically, many nonlinear oscillatory mechanical systems with a partitioned Hamiltonian function lend themselves to this approach. The extended discrete gradient formula presented in this paper exactly preserves the energy H(p, q). We derive some properties of the new formula. The convergence is analyzed for the implicit schemes based on the discrete gradient formula, and it turns out that the convergence of the implicit schemes based on the extended discrete gradient formula is independent of ‖M‖, which is a significant property for the oscillatory Hamiltonian system. Thus, it transpires that a larger step size can be chosen for the new energy-preserving schemes than that for the traditional discrete gradient methods when applied to the oscillatory Hamiltonian system. Illustrative examples show the competence and efficiency of the new schemes in comparison with the traditional discrete gradient methods in the scientific literature. (paper)

  20. Gradient Dynamics and Entropy Production Maximization

    Science.gov (United States)

    Janečka, Adam; Pavelka, Michal

    2018-01-01

    We compare two methods for modeling dissipative processes, namely gradient dynamics and entropy production maximization. Both methods require similar physical inputs-how energy (or entropy) is stored and how it is dissipated. Gradient dynamics describes irreversible evolution by means of dissipation potential and entropy, it automatically satisfies Onsager reciprocal relations as well as their nonlinear generalization (Maxwell-Onsager relations), and it has statistical interpretation. Entropy production maximization is based on knowledge of free energy (or another thermodynamic potential) and entropy production. It also leads to the linear Onsager reciprocal relations and it has proven successful in thermodynamics of complex materials. Both methods are thermodynamically sound as they ensure approach to equilibrium, and we compare them and discuss their advantages and shortcomings. In particular, conditions under which the two approaches coincide and are capable of providing the same constitutive relations are identified. Besides, a commonly used but not often mentioned step in the entropy production maximization is pinpointed and the condition of incompressibility is incorporated into gradient dynamics.

  1. Microinstabilities in weak density gradient tokamak systems

    International Nuclear Information System (INIS)

    Tang, W.M.; Rewoldt, G.; Chen, L.

    1986-04-01

    A prominent characteristic of auxiliary-heated tokamak discharges which exhibit improved (''H-mode type'') confinement properties is that their density profiles tend to be much flatter over most of the plasma radius. Depsite this favorable trend, it is emphasized here that, even in the limit of zero density gradient, low-frequency microinstabilities can persist due to the nonzero temperature gradient

  2. Imaging the Buried Chicxulub Crater with Gravity Gradients and Cenotes

    Science.gov (United States)

    Hildebrand, A. R.; Pilkington, M.; Halpenny, J. F.; Ortiz-Aleman, C.; Chavez, R. E.; Urrutia-Fucugauchi, J.; Connors, M.; Graniel-Castro, E.; Camara-Zi, A.; Vasquez, J.

    1995-09-01

    Differing interpretations of the Bouguer gravity anomaly over the Chicxulub crater, Yucatan Peninsula, Mexico, have yielded diameter estimates of 170 to 320 km. Knowing the crater's size is necessary to quantify the lethal perturbations to the Cretaceous environment associated with its formation. The crater's size (and internal structure) is revealed by the horizontal gradient of the Bouguer gravity anomaly over the structure, and by mapping the karst features of the Yucatan region. To improve our resolution of the crater's gravity signature we collected additional gravity measurements primarily along radial profiles, but also to fill in previously unsurveyed areas. Horizontal gradient analysis of Bouguer gravity data objectively highlights the lateral density contrasts of the impact lithologies and suppresses regional anomalies which may obscure the gravity signature of the Chicxulub crater lithologies. This gradient technique yields a striking circular structure with at least 6 concentric gradient features between 25 and 85 km radius. These features are most distinct in the southwest probably because of denser sampling of the gravity field. Our detailed profiles detected an additional feature and steeper gradients (up to 5 mGal/km) than the original survey. We interpret the outer four gradient maxima to represent concentric faults in the crater's zone of slumping as is also revealed by seismic reflection data. The inner two probably represent the margin of the central uplift and the peak ring and or collapsed transient cavity. Radial gradients in the SW quadrant over the inferred ~40 km-diameter central uplift (4) may represent structural "puckering" as revealed at eroded terrestrial craters. Gradient features related to regional gravity highs and lows are visible outside the crater, but no concentric gradient features are apparent at distances > 90 km radius. The marginal gradient features may be modelled by slump faults as observed in large complex craters on

  3. Gradient pattern analysis applied to galaxy morphology

    Science.gov (United States)

    Rosa, R. R.; de Carvalho, R. R.; Sautter, R. A.; Barchi, P. H.; Stalder, D. H.; Moura, T. C.; Rembold, S. B.; Morell, D. R. F.; Ferreira, N. C.

    2018-06-01

    Gradient pattern analysis (GPA) is a well-established technique for measuring gradient bilateral asymmetries of a square numerical lattice. This paper introduces an improved version of GPA designed for galaxy morphometry. We show the performance of the new method on a selected sample of 54 896 objects from the SDSS-DR7 in common with Galaxy Zoo 1 catalogue. The results suggest that the second gradient moment, G2, has the potential to dramatically improve over more conventional morphometric parameters. It separates early- from late-type galaxies better (˜ 90 per cent) than the CAS system (C˜ 79 per cent, A˜ 50 per cent, S˜ 43 per cent) and a benchmark test shows that it is applicable to hundreds of thousands of galaxies using typical processing systems.

  4. Abundance gradients in disc galaxies and chemical evolution models

    International Nuclear Information System (INIS)

    Diaz, A.I.

    1989-01-01

    The present state of abundance gradients and chemical evolution models of spiral galaxies is reviewed. An up to date compilation of abundance data in the literature concerning HII regions over galactic discs is presented. From these data Oxygen and Nitrogen radial gradients are computed. The slope of the Oxygen gradient is shown to have a break at a radius between 1.5 and 1.75 times the value of the effective radius of the disc, i.e. the radius containing half of the light of the disc. The gradient is steeper in the central parts of the disc and becomes flatter in the outer parts. N/O gradients are shown to be rather different from galaxy to galaxy and only a weak trend of N/O with O/H is found. The existing chemical evolution models for spiral galaxies are reviewed with special emphasis in the interpretation of numerical models having a large number of parameters. (author)

  5. Discrete gradient methods for solving variational image regularisation models

    International Nuclear Information System (INIS)

    Grimm, V; McLachlan, Robert I; McLaren, David I; Quispel, G R W; Schönlieb, C-B

    2017-01-01

    Discrete gradient methods are well-known methods of geometric numerical integration, which preserve the dissipation of gradient systems. In this paper we show that this property of discrete gradient methods can be interesting in the context of variational models for image processing, that is where the processed image is computed as a minimiser of an energy functional. Numerical schemes for computing minimisers of such energies are desired to inherit the dissipative property of the gradient system associated to the energy and consequently guarantee a monotonic decrease of the energy along iterations, avoiding situations in which more computational work might lead to less optimal solutions. Under appropriate smoothness assumptions on the energy functional we prove that discrete gradient methods guarantee a monotonic decrease of the energy towards stationary states, and we promote their use in image processing by exhibiting experiments with convex and non-convex variational models for image deblurring, denoising, and inpainting. (paper)

  6. Microstructural gradients in thin hard coatings -- tailor-made

    DEFF Research Database (Denmark)

    Pantleon, Karen; Oettel, Heinrich

    1998-01-01

    ) alternating sputtering with and without substrate voltage and (c) pulsed bias voltage. On the basis of X-ray diffraction measurements, it is demonstrated that residual stress gradients and texture gradients can be designed tailor-made. Furthermore, results of microhardness measurements and scratch tests...

  7. The Compression Intensity Index: a practical anatomical estimate of the biomechanical risk for a deep tissue injury.

    Science.gov (United States)

    Gefen, Amit

    2008-01-01

    Pressure-related deep tissue injury (DTI) is a severe form of pressure ulcer that initiates in compressed muscle tissues under bony prominences, and progresses superficially towards the skin. Patients with impaired motosensory capacities are at high risk of developing DTI. There is a critical medical need for developing risk assessment tools for DTI. A new anatomical index, the Compression Intensity Index: CII=(BW/Rt);[1/2], which depends on the body weight (BW), radius of curvature of the ischial tuberosities (R) and thickness of the underlying gluteus muscles (t), is suggested for approximating the loading intensity in muscle tissue during sitting in permanent wheelchair users, as part of a clinically-oriented risk assessment for DTI. Preliminary CII data were calculated for 6 healthy and 4 paraplegic subjects following MRI scans, and data were compared between the groups and with respect to a gold standard, being a previously developed subject-specific MRI-finite-element (MRI-FE) method of calculating muscle tissue stresses (Linder-Ganz et al., J. Biomech. 2007). Marked differences between the R and t parameters of the two groups caused the CII values of the paraplegics to be approximately 1.6-fold higher than for the healthy (pbedridden patients. Hence, CII measurements can be integrated into DTI-risk-assessment tools, the need of which is now being discussed intensively in the American and European Pressure Ulcer Advisory Panel meetings.

  8. Longitudinal diffusion tensor imaging in amyotrophic lateral sclerosis

    Directory of Open Access Journals (Sweden)

    Keil Carsten

    2012-11-01

    Full Text Available Abstract Background Amyotrophic lateral sclerosis (ALS is a fatal neurodegenerative disorder, caused by progressive loss of motor neurons. Changes are widespread in the subcortical white matter in ALS. Diffusion tensor imaging (DTI detects pathological changes in white matter fibres in vivo, based on alterations in the degree (diffusivity, ADC and directedness (fractional anisotropy, FA of proton movement. Methods 24 patients with ALS and 24 age-matched controls received 1.5T DTI. FA and ADC were analyzed using statistical parametric mapping. In 15 of the 24 ALS patients, a second DTI was obtained after 6 months. Results Decreased FA in the corticospinal tract (CST and frontal areas confirm existing results. With a direct comparison of baseline and follow-up dataset, the progression of upper motor neuron degeneration, reflected in FA decrease, could be captured along the CST and in frontal areas. The involvement of cerebellum in the pathology of ALS, as suspected from functional MRI studies, could be confirmed by a reduced FA (culmen, declive. These structural changes correlated well with disease duration, ALSFRS-R, and physical and executive functions. Conclusion DTI detects changes that are regarded as prominent features of ALS and thus, shows promise in its function as a biomarker. Using the technique herein, we could demonstrate DTI changes at follow-up which correlated well with clinical progression.

  9. Magnetic field of longitudinal gradient bend

    Science.gov (United States)

    Aiba, Masamitsu; Böge, Michael; Ehrlichman, Michael; Streun, Andreas

    2018-06-01

    The longitudinal gradient bend is an effective method for reducing the natural emittance in light sources. It is, however, not a common element. We have analyzed its magnetic field and derived a set of formulae. Based on the derivation, we discuss how to model the longitudinal gradient bend in accelerator codes that are used for designing electron storage rings. Strengths of multipole components can also be evaluated from the formulae, and we investigate the impact of higher order multipole components in a very low emittance lattice.

  10. Subsurface temperatures and geothermal gradients on the North Slope, Alaska

    Science.gov (United States)

    Collett, Timothy S.; Bird, Kenneth J.; Magoon, Leslie B.

    1989-01-01

    Geothermal gradients as interpreted from a series of high-resolution stabilized well-bore-temperature surveys from 46 North Slope, Alaska, wells vary laterally and vertically throughout the near-surface sediment (0-2,000 m). The data from these surveys have been used in conjunction with depths of ice-bearing permafrost, as interpreted from 102 well logs, to project geothermal gradients within and below the ice-bearing permafrost sequence. The geothermal gradients calculated from the projected temperature profiles are similar to the geothermal gradients measured in the temperature surveys. Measured and projected geothermal gradients in the ice-bearing permafrost sequence range from 1.5??C/100m in the Prudhoe Bay area to 5.1??C/100m in the National Petroleum Reserve in Alaska (NPRA).

  11. Application of quantitative DTI metrics in sporadic CJD

    Directory of Open Access Journals (Sweden)

    E. Caverzasi

    2014-01-01

    Full Text Available Diffusion Weighted Imaging is extremely important for the diagnosis of probable sporadic Jakob–Creutzfeldt disease, the most common human prion disease. Although visual assessment of DWI MRI is critical diagnostically, a more objective, quantifiable approach might more precisely identify the precise pattern of brain involvement. Furthermore, a quantitative, systematic tracking of MRI changes occurring over time might provide insights regarding the underlying histopathological mechanisms of human prion disease and provide information useful for clinical trials. The purposes of this study were: 1 to describe quantitatively the average cross-sectional pattern of reduced mean diffusivity, fractional anisotropy, atrophy and T1 relaxation in the gray matter (GM in sporadic Jakob–Creutzfeldt disease, 2 to study changes in mean diffusivity and atrophy over time and 3 to explore their relationship with clinical scales. Twenty-six sporadic Jakob–Creutzfeldt disease and nine control subjects had MRIs on the same scanner; seven sCJD subjects had a second scan after approximately two months. Cortical and subcortical gray matter regions were parcellated with Freesurfer. Average cortical thickness (or subcortical volume, T1-relaxiation and mean diffusivity from co-registered diffusion maps were calculated in each region for each subject. Quantitatively on cross-sectional analysis, certain brain regions were preferentially affected by reduced mean diffusivity (parietal, temporal lobes, posterior cingulate, thalamus and deep nuclei, but with relative sparing of the frontal and occipital lobes. Serial imaging, surprisingly showed that mean diffusivity did not have a linear or unidirectional reduction over time, but tended to decrease initially and then reverse and increase towards normalization. Furthermore, there was a strong correlation between worsening of patient clinical function (based on modified Barthel score and increasing mean diffusivity.

  12. Gradient-Index Optics

    Science.gov (United States)

    2010-03-31

    nonimaging design capabilities to incorporate 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 12-04-2011 13. SUPPLEMENTARY NOTES The views, opinions...Box 12211 Research Triangle Park, NC 27709-2211 15. SUBJECT TERMS Imaging Optics, Nonimaging Optics, Gradient Index Optics, Camera, Concentrator...imaging and nonimaging design capabilities to incorporate manufacturable GRIN lenses can provide imaging lens systems that are compact and

  13. Two dimensional dynamic analysis of sandwich plates with gradient foam cores

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Lin; Xiao, Deng Bao; Zhao, Guiping [State Key Laboratory for Mechanical structure Strength and Vibration, School of AerospaceXi' an Jiaotong University, Xi' an (China); Cho, Chong Du [Dept. of Mechanical Engineering, Inha University, Inchon (Korea, Republic of)

    2016-09-15

    Present investigation is concerned about dynamic response of composite sandwich plates with the functionally gradient foam cores under time-dependent impulse. The analysis is based on a model of the gradient sandwich plate, in which the face sheets and the core adopt the Kirchhoff theory and a [2, 1]-order theory, respectively. The material properties of the gradient foam core vary continuously along the thickness direction. The gradient plate model is validated with the finite element code ABAQUS®. And the results show that the proposed model can predict well the free vibration of composite sandwich plates with gradient foam cores. The influences of gradient foam cores on the natural frequency, deflection and energy absorbing of the sandwich plates are also investigated.

  14. Enhanced Photovoltaic Properties of Gradient Doping Solar Cells

    International Nuclear Information System (INIS)

    Zhang Chun-Lei; Du Hui-Jing; Zhu Jian-Zhuo; Xu Tian-Fu; Fang Xiao-Yong

    2012-01-01

    An optimum design of a-Si:H(n)/a-Si:H(i)/c-Si(p) heterojunction solar cell is realized with 24.27% conversion efficiency by gradient doping of the a-Si:H(n) layer. The photovoltaic properties are simulated by the AFORSHET software. Besides the additional electric field caused by the gradient doping, the enhanced and widen spectral response also improves the solar cell performance compared with the uniform-doping mode. The simulation shows that the gradient doping is efficient to improve the photovoltaic performance of the solar cells. The study is valuable for the solar cell design with excellent performances

  15. Geomorphic controls on elevational gradients of species richness.

    Science.gov (United States)

    Bertuzzo, Enrico; Carrara, Francesco; Mari, Lorenzo; Altermatt, Florian; Rodriguez-Iturbe, Ignacio; Rinaldo, Andrea

    2016-02-16

    Elevational gradients of biodiversity have been widely investigated, and yet a clear interpretation of the biotic and abiotic factors that determine how species richness varies with elevation is still elusive. In mountainous landscapes, habitats at different elevations are characterized by different areal extent and connectivity properties, key drivers of biodiversity, as predicted by metacommunity theory. However, most previous studies directly correlated species richness to elevational gradients of potential drivers, thus neglecting the interplay between such gradients and the environmental matrix. Here, we investigate the role of geomorphology in shaping patterns of species richness. We develop a spatially explicit zero-sum metacommunity model where species have an elevation-dependent fitness and otherwise neutral traits. Results show that ecological dynamics over complex terrains lead to the null expectation of a hump-shaped elevational gradient of species richness, a pattern widely observed empirically. Local species richness is found to be related to the landscape elevational connectivity, as quantified by a newly proposed metric that applies tools of complex network theory to measure the closeness of a site to others with similar habitat. Our theoretical results suggest clear geomorphic controls on elevational gradients of species richness and support the use of the landscape elevational connectivity as a null model for the analysis of the distribution of biodiversity.

  16. Competitive ability, stress tolerance and plant interactions along stress gradients.

    Science.gov (United States)

    Qi, Man; Sun, Tao; Xue, SuFeng; Yang, Wei; Shao, DongDong; Martínez-López, Javier

    2018-04-01

    Exceptions to the generality of the stress-gradient hypothesis (SGH) may be reconciled by considering species-specific traits and stress tolerance strategies. Studies have tested stress tolerance and competitive ability in mediating interaction outcomes, but few have incorporated this to predict how species interactions shift between competition and facilitation along stress gradients. We used field surveys, salt tolerance and competition experiments to develop a predictive model interspecific interaction shifts across salinity stress gradients. Field survey and greenhouse tolerance tests revealed tradeoffs between stress tolerance and competitive ability. Modeling showed that along salinity gradients, (1) plant interactions shifted from competition to facilitation at high salinities within the physiological limits of salt-intolerant plants, (2) facilitation collapsed when salinity stress exceeded the physiological tolerance of salt-intolerant plants, and (3) neighbor removal experiments overestimate interspecific facilitation by including intraspecific effects. A community-level field experiment, suggested that (1) species interactions are competitive in benign and, facilitative in harsh condition, but fuzzy under medium environmental stress due to niche differences of species and weak stress amelioration, and (2) the SGH works on strong but not weak stress gradients, so SGH confusion arises when it is applied across questionable stress gradients. Our study clarifies how species interactions vary along stress gradients. Moving forward, focusing on SGH applications rather than exceptions on weak or nonexistent gradients would be most productive. © 2018 by the Ecological Society of America.

  17. Stability of Gradient Field Corrections for Quantitative Diffusion MRI

    OpenAIRE

    Rogers, Baxter P.; Blaber, Justin; Welch, E. Brian; Ding, Zhaohua; Anderson, Adam W.; Landman, Bennett A.

    2017-01-01

    In magnetic resonance diffusion imaging, gradient nonlinearity causes significant bias in the estimation of quantitative diffusion parameters such as diffusivity, anisotropy, and diffusion direction in areas away from the magnet isocenter. This bias can be substantially reduced if the scanner- and coil-specific gradient field nonlinearities are known. Using a set of field map calibration scans on a large (29 cm diameter) phantom combined with a solid harmonic approximation of the gradient fie...

  18. The Carbon Trust and DTI Renewables network impacts study

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, Mott

    2005-11-15

    The study's key objectives, as set by the Renewables Advisory Board, the Carbon Trust and DTI, are as follows: To undertake a forward renewables capacity mapping exercise derived from the generation companies' investment plans to 2010, and if the capacity mapping exercise indicates that the planned level of activity is unlikely to meet the 2010 target, to devise and consider a small number of scenarios whereby the 10% target could be achieved; To determine how the transmission and distribution networks need to evolve to enable the Government's 2010 target of 10% of electricity supplied from renewable sources and the aspiration to double that percentage; To investigate the network issues regarding the intermittent nature of renewable generation and the characterisation of renewable generation with regard to grid code compliance; To provide insights into the actions and the stepping stones required between now and 2020 for the key decisions and investments relating to the transformation of the transmission and distribution network, and those issues likely to affect the rate of progress toward the targets. The study also analyses whether there are potential network impacts on renewables expansion from a simultaneous expansion of the UK's CHP capacity to meet the Government target of 10GW of CHP by 2010. The study (which was largely completed ahead of the Government's announcement on extension of the Renewables Obligation Order to 2015, and the raising of the renewables target to 15% of electricity sales by 2015) has found that based on business plans, developers can meet about 72% of the 2010 target by 20061. The Government's announcement has been welcomed by the renewables community and is expected to give added confidence to developers and investors that the Government is intent on creating a long term stable regime to incentivise investment in renewable energy technologies. However, in parallel with tackling what was a decline in

  19. The Emerging Role of Tractography in Deep Brain Stimulation: Basic Principles and Current Applications

    Directory of Open Access Journals (Sweden)

    Nelson B. Rodrigues

    2018-01-01

    Full Text Available Diffusion tensor imaging (DTI is an MRI-based technique that delineates white matter tracts in the brain by tracking the diffusion of water in neural tissue. This methodology, known as “tractography”, has been extensively applied in clinical neuroscience to explore nervous system architecture and diseases. More recently, tractography has been used to assist with neurosurgical targeting in functional neurosurgery. This review provides an overview of DTI principles, and discusses current applications of tractography for improving and helping develop novel deep brain stimulation (DBS targets.

  20. Gradients of microhabitat and crappie (Pomoxis spp.) distributions in reservoir coves

    Science.gov (United States)

    Kaczka, Levi J.; Miranda, Leandro E.

    2013-01-01

    Embayments are among the most widespread littoral habitats found in Mississippi flood-control reservoirs. These macrohabitats represent commonly used nursery zones for age-0 crappies, Pomoxis spp., despite barren and eroded shorelines formed over 60–70 years of annual water level fluctuations. We tested if embayments displayed microhabitat gradients linked to the effect of water level fluctuations on riparian vegetation and if these gradients were paralleled by gradients in age-0 crappie distribution. Habitat composition changed longitudinally along the embayments with the most pronounced gradient representing a shift from nonvegetated mudflats near the mouth of embayments to herbaceous material upstream. The degree of habitat change depended on the water level. Similarly, catch rates of crappies increased upstream toward the rear of embayments, differing among water levels and reservoirs, but the longitudinal pattern persisted. Our results indicate that habitat composition gradients occur in embayments of northwest Mississippi flood-control reservoirs and that these gradients may influence a similar gradient in age-0 crappie distribution. While the biotic interactions behind the gradients may be less clear, we speculate that water level is the main factor influencing the observed gradients in habitat composition and fish. Management to benefit age-0 crappies may involve habitat improvement along embayment shorelines and water level regimes that foster growth of herbaceous plants.

  1. Calculation of Vertical Temperature Gradients in Heated Rooms

    DEFF Research Database (Denmark)

    Overby, H.; Steen-Thøde, Mogens

    This paper deals with a simple model which predicts the vertical temperature gradient in a heated room. The gradient is calculated from a dimensionless temperature profile which is determined by two room air temperatures only, the mean temperature in the occupied zone and the mean temperature...

  2. Elevational gradient in the cyclicity of a forest-defoliating insect

    Science.gov (United States)

    Kyle J. Haynes; Andrew M. Liebhold; Derek M. Johnson

    2012-01-01

    Observed changes in the cyclicity of herbivore populations along latitudinal gradients and the hypothesis that shifts in the importance of generalist versus specialist predators explain such gradients has long been a matter of intense interest. In contrast, elevational gradients in population cyclicity are largely unexplored. We quantified the cyclicity of gypsy moth...

  3. Topological charge using cooling and the gradient flow

    International Nuclear Information System (INIS)

    Alexandrou, C.; Athenodorou, A.; The Cyprus Institute, Nicosia; Jansen, K.

    2015-12-01

    The equivalence of cooling to the gradient flow when the cooling step n c and the continuous flow step of gradient flow τ are matched is generalized to gauge actions that include rectangular terms. By expanding the link variables up to subleading terms in perturbation theory, we relate n c and τ and show that the results for the topological charge become equivalent when rescaling τ ≅ n c /(3-15c 1 ) where c 1 is the Symanzik coefficient multiplying the rectangular term. We, subsequently, apply cooling and the gradient flow using the Wilson, the Symanzik tree-level improved and the Iwasaki gauge actions to configurations produced with N f = 2 + 1 + 1 twisted mass fermions. We compute the topological charge, its distribution and the correlators between cooling and gradient flow at three values of the lattice spacing demonstrating that the perturbative rescaling τ ≅ n c /(3-15c 1 ) leads to equivalent results.

  4. Lactate uptake against a concentration gradient

    DEFF Research Database (Denmark)

    Nordström, Carl-Henrik; Nielsen, Troels Halfeld; Nielsen, Hans Boye

    2014-01-01

    The recently published article by Jalloh et al (Jalloh I, Helmy A, Shannon RJ, Gallagher CN, Menon D, Carpenter K, Hutchinson P. Lactate uptake by the injured human brain - evidence from an arterio-venous gradient and cerebral microdialysis study. J Neurotrauma. 2013 Aug 22. [Epub ahead of print......]) concludes that lactate may be transported across the blood brain barrier into the brain against a concentration gradient. Unfortunately the authors have misinterpreted the concept of analytical imprecision and their conclusion is based on analytical artifact. As the topic of lactate transport into the brain...

  5. Economic gradients in early child neurodevelopment: A multi-country study

    Science.gov (United States)

    Wehby, George L.; McCarthy, Ann Marie

    2013-01-01

    Little is known about the importance of household wealth for child neurodevelopment very early in life including during infancy. Previous studies have focused on specific developmental domains instead of more holistic multi-domain measures of neurodevelopment and on economic effects for the “average” child instead of evaluating the heterogeneity in economic gradients by different levels of developmental ability. Furthermore, not much is known about whether economic gradients in early child neurodevelopment are country-specific or generalizable between populations. We evaluate wealth gradients in child neurodevelopment, an important predictor of future health and human capital, between ages 3 and 24 months in four South American countries. We also assess the heterogeneity in these gradients at different locations of the neurodevelopment distribution using quantile regression. Employing a unique dataset of 2032 children with neurodevelopment measures obtained by physicians in 2005–2006, we find a large positive wealth gradient in neurodevelopment in Brazil. The wealth gradient is larger for children at higher neurodevelopment rankings, suggesting that wealth is associated with child development inequalities in the form of a wider gap between low and high achievers on neurodevelopment in Brazil. This result highlights the need to target poverty in Brazil as a key factor in health and human capital disparities earlier in life rather than later as early developmental deficits will be carried forward and possibly multiplied later in life. More importantly, small or insignificant wealth gradients are generally found in the other countries. These results suggest that wealth gradients in child neurodevelopment are country-specific and vary with population demographic, health, and socioeconomic characteristics. Therefore, findings from previous studies based on specific populations may not be generalizable to other countries. Furthermore, wealth gradients in child

  6. High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yokoyama, Shunichi; Uomizu, Kenji; Kajiya, Yoriko; Tajitsu, Kenichiro; Kusumoto, Kazuhiro; Hirano, Hirofumi

    2005-01-01

    The incidence and characteristics of microbleeds in hemodialysis (HD) patients were investigated to elucidate the clinical significance with T 2 * -weighted gradient-echo magnetic resonance (MR) imaging. The 57 patients with chronic renal failure maintained by HD had no previous history of stroke. The control group consisted of 53 patients without previous history of stroke or chronic renal failure. The incidence and the number of microbleeds were assessed in the HD and control groups. The findings of microbleeds with T 2 * -weighted gradient-echo MR imaging were compared with those of T 1 - and T 2 -weighted MR imaging in HD patients. The incidence of microbleeds was significantly greater in the HD patients compared with the control patients. T 2 * -weighted gradient-echo imaging revealed a total of 44 microbleeds in 11 HD patients. T 2 -weighted imaging demonstrated 13 of 44 microbleeds as hyperintensity, whereas T 1 -weighted imaging demonstrated 12 lesions as hypointensity. T 2 - and T 1 -weighted imagings did not demonstrate any findings in 31 and 32 lesions, respectively. T 2 * -weighted gradient-echo MR imaging is effective to detect microbleeds which may be a predictor of intracerebral hemorrhage in HD patients and should be included in the protocol for the study of cerebrovascular disease, because T 2 - and T 1 -weighted MR imaging recognizes microbleeds as lacunar infarction. (author)

  7. A parametric study of adverse pressure gradient turbulent boundary layers

    International Nuclear Information System (INIS)

    Monty, J.P.; Harun, Z.; Marusic, I.

    2011-01-01

    There are many open questions regarding the behaviour of turbulent boundary layers subjected to pressure gradients and this is confounded by the large parameter space that may affect these flows. While there have been many valuable investigations conducted within this parameter space, there are still insufficient data to attempt to reduce this parameter space. Here, we consider a parametric study of adverse pressure gradient turbulent boundary layers where we restrict our attention to the pressure gradient parameter, β, the Reynolds number and the acceleration parameter, K. The statistics analyzed are limited to the streamwise fluctuating velocity. The data show that the mean velocity profile in strong pressure gradient boundary layers does not conform to the classical logarithmic law. Moreover, there appears to be no measurable logarithmic region in these cases. It is also found that the large-scale motions scaling with outer variables are energised by the pressure gradient. These increasingly strong large-scale motions are found to be the dominant contributor to the increase in turbulence intensity (scaled with friction velocity) with increasing pressure gradient across the boundary layer.

  8. Advances in high-gradient magnetic fishing for bioprocessing

    DEFF Research Database (Denmark)

    Goncalves Gomes, Claudia Sofia

    2006-01-01

    “High-gradient magnetic fishing” (HGMF) er en metode til processering af fødestrømme med biologiske molekyler. HGMF integrerer brugen af superparamagnetiske adsorbenter med separation og processering med høj-gradient magnetisk separation (HGMS) i et magnetisk filter. Adsorbenterne er uporøse og...

  9. Retinal Microaneurysms Detection Using Gradient Vector Analysis and Class Imbalance Classification.

    Science.gov (United States)

    Dai, Baisheng; Wu, Xiangqian; Bu, Wei

    2016-01-01

    Retinal microaneurysms (MAs) are the earliest clinically observable lesions of diabetic retinopathy. Reliable automated MAs detection is thus critical for early diagnosis of diabetic retinopathy. This paper proposes a novel method for the automated MAs detection in color fundus images based on gradient vector analysis and class imbalance classification, which is composed of two stages, i.e. candidate MAs extraction and classification. In the first stage, a candidate MAs extraction algorithm is devised by analyzing the gradient field of the image, in which a multi-scale log condition number map is computed based on the gradient vectors for vessel removal, and then the candidate MAs are localized according to the second order directional derivatives computed in different directions. Due to the complexity of fundus image, besides a small number of true MAs, there are also a large amount of non-MAs in the extracted candidates. Classifying the true MAs and the non-MAs is an extremely class imbalanced classification problem. Therefore, in the second stage, several types of features including geometry, contrast, intensity, edge, texture, region descriptors and other features are extracted from the candidate MAs and a class imbalance classifier, i.e., RUSBoost, is trained for the MAs classification. With the Retinopathy Online Challenge (ROC) criterion, the proposed method achieves an average sensitivity of 0.433 at 1/8, 1/4, 1/2, 1, 2, 4 and 8 false positives per image on the ROC database, which is comparable with the state-of-the-art approaches, and 0.321 on the DiaRetDB1 V2.1 database, which outperforms the state-of-the-art approaches.

  10. Diffusion tensor imaging for target volume definition in glioblastoma multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Berberat, Jatta; Remonda, Luca [Cantonal Hospital, Department of Neuro-radiology, Aarau (Switzerland); McNamara, Jane; Rogers, Susanne [Cantonal Hospital, Department of Radiation Oncology, Aarau (Switzerland); Bodis, Stephan [Cantonal Hospital, Department of Radiation Oncology, Aarau (Switzerland); University Hospital, Department of Radiation Oncology, Zurich (Switzerland)

    2014-10-15

    Diffusion tensor imaging (DTI) is an MR-based technique that may better detect the peritumoural region than MRI. Our aim was to explore the feasibility of using DTI for target volume delineation in glioblastoma patients. MR tensor tracts and maps of the isotropic (p) and anisotropic (q) components of water diffusion were coregistered with CT in 13 glioblastoma patients. An in-house image processing program was used to analyse water diffusion in each voxel of interest in the region of the tumour. Tumour infiltration was mapped according to validated criteria and contralateral normal brain was used as an internal control. A clinical target volume (CTV) was generated based on the T{sub 1}-weighted image obtained using contrast agent (T{sub 1Gd}), tractography and the infiltration map. This was compared to a conventional T{sub 2}-weighted CTV (T{sub 2}-w CTV). Definition of a diffusion-based CTV that included the adjacent white matter tracts proved highly feasible. A statistically significant difference was detected between the DTI-CTV and T{sub 2}-w CTV volumes (p < 0.005, t = 3.480). As the DTI-CTVs were smaller than the T{sub 2}-w CTVs (tumour plus peritumoural oedema), the pq maps were not simply detecting oedema. Compared to the clinical planning target volume (PTV), the DTI-PTV showed a trend towards volume reduction. These diffusion-based volumes were smaller than conventional volumes, yet still included sites of tumour recurrence. Extending the CTV along the abnormal tensor tracts in order to preserve coverage of the likely routes of dissemination, whilst sparing uninvolved brain, is a rational approach to individualising radiotherapy planning for glioblastoma patients. (orig.) [German] Die Diffusions-Tensor-Bildgebung (DTI) ist eine MR-Technik, die dank der Erfassung des peritumoralen Bereichs eine Verbesserung bezueglich MRI bringt. Unser Ziel war die Pruefung der Machbarkeit der Verwendung der DTI fuer die Zielvolumenabgrenzung fuer Patienten mit

  11. Diffusiophoresis in one-dimensional solute gradients

    International Nuclear Information System (INIS)

    Ault, Jesse T.; Warren, Patrick B.; Shin, Sangwoo; Stone, Howard A.

    2017-01-01

    Here, the diffusiophoretic motion of suspended colloidal particles under one-dimensional solute gradients is solved using numerical and analytical techniques. Similarity solutions are developed for the injection and withdrawal dynamics of particles into semi-infinite pores. Furthermore, a method of characteristics formulation of the diffusion-free particle transport model is presented and integrated to realize particle trajectories. Analytical solutions are presented for the limit of small particle diffusiophoretic mobility Γ p relative to the solute diffusivity D s for particle motions in both semi-infinite and finite domains. Results confirm the build up of local maxima and minima in the propagating particle front dynamics. The method of characteristics is shown to successfully predict particle motions and the position of the particle front, although it fails to accurately predict suspended particle concentrations in the vicinity of sharp gradients, such as at the particle front peak seen in some injection cases, where particle diffusion inevitably plays an important role. Results inform the design of applications in which the use of applied solute gradients can greatly enhance particle injection into and withdrawal from pores.

  12. SGH: stress or strain gradient hypothesis? Insights from an elevation gradient on the roof of the world.

    Science.gov (United States)

    Liancourt, Pierre; Le Bagousse-Pinguet, Yoann; Rixen, Christian; Dolezal, Jiri

    2017-07-01

    The stress gradient hypothesis (SGH), the view that competition prevails in undisturbed and productive environments, and shifts to facilitation in disturbed or stressful environments, has become a central paradigm in ecology. However, an alternative view proposes that the relationship between biotic interactions and environmental severity should be unimodal instead of monotonic. Possible causes of discrepancies between these two views were examined in the high elevation desert of the arid Trans-Himalayas. A putative nurse species and its associated plant community was surveyed over its entire elevation range, spanning from alpine to desert vegetation belts. The results were analysed at the community level (vegetation cover and species richness), considering the distinction between the intensity and the importance of biotic interactions. Interactions at the species level (pairwise interactions) were also considered, i.e. the variation of biotic interactions within the niche of a species, for which the abundance (species cover) and probability of occurrence (presence/absence) for the most widespread species along the gradient were distinguished. Overall, facilitation was infrequent in our study system; however, it was observed for the two most widespread species. At the community level, the intensity and importance of biotic interactions showed a unimodal pattern. The departure from the prediction of the SGH happened abruptly where the nurse species entered the desert vegetation belt at the lowest elevation. This abrupt shift was attributed to the turnover of species with contrasting tolerances. At the species level, however, facilitation increased consistently as the level of stress increases and individuals deviate from their optimum (increasing strain). While the stress gradient hypothesis was not supported along our elevation gradient at the community level, the strain gradient hypothesis, considering how species perceive the ambient level of stress and deviate

  13. Preliminary assessment of amyotrophic lateral sclerosis by using MRI and MR diffusion tensor imaging

    International Nuclear Information System (INIS)

    Ma Lin; Yin Hong; Cai Youquan; Li Dejun; Shen Dingguo

    2003-01-01

    Objective: To describe the characteristic MR findings in the brain in patients with amyotrophic lateral sclerosis (ALS), and to assess the diagnostic value of conventional MR imaging and fractional anisotropy (FA) of diffusion tensor imaging (DTI). Methods: Conventional MR imaging was performed in 14 clinically proved ALS patients and 12 age-matched normal controls. Contrast enhanced MR images were acquired in 2 patients. Axial and coronal DTI scans were performed in 10 patients and 12 normal controls with SE-EPI sequence. The b value was 1000 s/mm 2 , the number of diffusion sensitive gradient direction was 25. For quantitative assessment of the corticospinal tract (CST), FA value of bilateral CST was measured at the level of posterior limb (PL) of the internal capsule (IC) and the cerebral peduncle of the midbrain, respectively, and statistical analysis was performed. Results: Focal slight low signal intensity on T 1 WI and high signal intensity (hyperintense to gray matter) on T 2 WI was demonstrated in 6 ALS cases (42.9%) in bilateral PL of the IC, and the high signal was longitudinally continuous from the PL to the cerebral peduncle on T 2 WI coronal plane, corresponding to the course of CST. In another 8 ALS cases (57.1%), the focal slight low signal intensity on T 1 WI and slight high signal intensity (isointense to gray matter) on T 2 WI was revealed in bilateral PL of the IC. No abnormal contrast enhancement was detected in the 2 cases. In control group, the focal slight low signal intensity on T 1 WI and slight high signal intensity (isointense to gray matter) on T 2 WI was demonstrated in all 12 subjects in bilateral PL of the IC. FA values of the patient group were significantly lower than that of the control group at the level of the PL of the IC (F=7.38, P<0.01) and the cerebral peduncle (F=7.31, P=0.01), respectively. Conclusion: Clinical information must be considered when diagnosing ALS by using conventional MR imaging. The decreased FA value in

  14. Assembly of multiple cell gradients directed by three-dimensional microfluidic channels.

    Science.gov (United States)

    Li, Yiwei; Feng, Xiaojun; Wang, Yachao; Du, Wei; Chen, Peng; Liu, Chao; Liu, Bi-Feng

    2015-08-07

    Active control over the cell gradient is essential for understanding biological systems and the reconstitution of the functionality of many types of tissues, particularly for organ-on-a-chip. Here, we propose a three-dimensional (3D) microfluidic strategy for generating controllable cell gradients. In this approach, a homogeneous cell suspension is loaded into a 3D stair-shaped PDMS microchannel to generate a cell gradient within 10 min by sedimentation. We demonstrate that cell gradients of various profiles (exponential and piecewise linear) can be achieved by precisely controlling the height of each layer during the fabrication. With sequential seeding, we further demonstrate the generation of two overlapping cell gradients on the same glass substrate with pre-defined designs. The cell gradient-based QD cytotoxicity assay also demonstrated that cell behaviors and resistances were regulated by the changes in cell density. These results reveal that the proposed 3D microfluidic strategy provides a simple and versatile means for establishing controllable gradients in cell density, opening up a new avenue for reconstructing functional tissues.

  15. Gradient porous hydroxyapatite ceramics fabricated by freeze casting method

    International Nuclear Information System (INIS)

    Zuo Kaihui; Zhang Yuan; Jiang Dongliang; Zeng Yuping

    2011-01-01

    By controlling the cooling rates and the composition of slurries, the gradient porous hydroxyapatite ceramics are fabricated by the freeze casting method. According to the different cooling rate, the pores of HAP ceramics fabricated by gradient freeze casting are divided into three parts: one is lamellar pores, another is column pore and the last one is fine round pores. The laminated freeze casting is in favour of obtaining the gradient porous ceramics composed of different materials and the ceramics have unclear interfaces.

  16. Minimizing inner product data dependencies in conjugate gradient iteration

    Science.gov (United States)

    Vanrosendale, J.

    1983-01-01

    The amount of concurrency available in conjugate gradient iteration is limited by the summations required in the inner product computations. The inner product of two vectors of length N requires time c log(N), if N or more processors are available. This paper describes an algebraic restructuring of the conjugate gradient algorithm which minimizes data dependencies due to inner product calculations. After an initial start up, the new algorithm can perform a conjugate gradient iteration in time c*log(log(N)).

  17. LES of the adverse-pressure gradient turbulent boundary layer

    International Nuclear Information System (INIS)

    Inoue, M.; Pullin, D.I.; Harun, Z.; Marusic, I.

    2013-01-01

    Highlights: • The adverse-pressure gradient turbulent boundary layer at high Re is studied. • Wall-model LES works well for nonequilibrium turbulent boundary layer. • Relationship of skin-friction to Re and Clauser pressure parameter is explored. • Self-similarity is observed in the velocity statistics over a wide range of Re. -- Abstract: We describe large-eddy simulations (LES) of the flat-plate turbulent boundary layer in the presence of an adverse pressure gradient. The stretched-vortex subgrid-scale model is used in the domain of the flow coupled to a wall model that explicitly accounts for the presence of a finite pressure gradient. The LES are designed to match recent experiments conducted at the University of Melbourne wind tunnel where a plate section with zero pressure gradient is followed by section with constant adverse pressure gradient. First, LES are described at Reynolds numbers based on the local free-stream velocity and the local momentum thickness in the range 6560–13,900 chosen to match the experimental conditions. This is followed by a discussion of further LES at Reynolds numbers at approximately 10 times and 100 times these values, which are well out of range of present day direct numerical simulation and wall-resolved LES. For the lower Reynolds number runs, mean velocity profiles, one-point turbulent statistics of the velocity fluctuations, skin friction and the Clauser and acceleration parameters along the streamwise, adverse pressure-gradient domain are compared to the experimental measurements. For the full range of LES, the relationship of the skin-friction coefficient, in the form of the ratio of the local free-stream velocity to the local friction velocity, to both Reynolds number and the Clauser parameter is explored. At large Reynolds numbers, a region of collapse is found that is well described by a simple log-like empirical relationship over two orders of magnitude. This is expected to be useful for constant adverse

  18. Structural and Functional Brain Connectivity of People with Obesity and Prediction of Body Mass Index Using Connectivity.

    Directory of Open Access Journals (Sweden)

    Bo-yong Park

    Full Text Available Obesity is a medical condition affecting billions of people. Various neuroimaging methods including magnetic resonance imaging (MRI have been used to obtain information about obesity. We adopted a multi-modal approach combining diffusion tensor imaging (DTI and resting state functional MRI (rs-fMRI to incorporate complementary information and thus better investigate the brains of non-healthy weight subjects. The objective of this study was to explore multi-modal neuroimaging and use it to predict a practical clinical score, body mass index (BMI. Connectivity analysis was applied to DTI and rs-fMRI. Significant regions and associated imaging features were identified based on group-wise differences between healthy weight and non-healthy weight subjects. Six DTI-driven connections and 10 rs-fMRI-driven connectivities were identified. DTI-driven connections better reflected group-wise differences than did rs-fMRI-driven connectivity. We predicted BMI values using multi-modal imaging features in a partial least-square regression framework (percent error 15.0%. Our study identified brain regions and imaging features that can adequately explain BMI. We identified potentially good imaging biomarker candidates for obesity-related diseases.

  19. Fiber tracking for brain tumor

    International Nuclear Information System (INIS)

    Yamada, Kei; Nakamura, Hisao; Ito, Hirotoshi; Tanaka, Osamu; Kubota, Takao; Yuen, Sachiko; Kizu, Osamu; Nishimura, Tsunehiko

    2003-01-01

    The purpose of this study was to validate an innovative scanning method for patients diagnosed with brain tumors. Using a 1.5 Tesla whole body magnetic resonance (MR) imager, 23 patients with brain tumors were scanned. The recorded data points of the diffusion-tensor imaging (DTI) sequences were 128 x 37 with the parallel imaging technique. The parallel imaging technique was equivalent to a true resolution of 128 x 74. The scan parameters were repetition time (TR)=6000, echo time (TE)=88, 6 averaging with a b-value of 800 s/mm 2 . The total scan time for DTI was 4 minutes and 24 seconds. DTI scans and subsequent fiber tracking were successfully applied in all cases. All fiber tracts on the contralesional side were visualized in the expected locations. Fiber tracts on the lesional side had varying degrees of displacement, disruption, or a combination of displacement and disruption due to the tumor. Tract disruption resulted from direct tumor involvement, compression upon the tract, and vasogenic edema surrounding the tumor. This DTI method using a parallel imaging technique allows for clinically feasible fiber tracking that can be incorporated into a routine MR examination. (author)

  20. The evolving approach to the evaluation of low-gradient aortic stenosis.

    Science.gov (United States)

    Cutting, William B; Bavry, Anthony A

    2018-04-07

    Severe aortic stenosis (AS) is typically identified by a low valve area (≤1.0 cm 2 ) and high mean gradient (≥40 mm Hg). A subset of patients are found to have a less than severe mean gradient (gradient AS (stage D2) or normal ejection fraction with low-gradient AS (stage D3). Determining the true severity of disease within these categories has proved difficult. In this review we illustrate both traditional and novel techniques that can be used for further valvular assessment. We also propose a simple algorithm that can be used to evaluate low-gradient AS. Published by Elsevier Inc.

  1. Regularized image denoising based on spectral gradient optimization

    International Nuclear Information System (INIS)

    Lukić, Tibor; Lindblad, Joakim; Sladoje, Nataša

    2011-01-01

    Image restoration methods, such as denoising, deblurring, inpainting, etc, are often based on the minimization of an appropriately defined energy function. We consider energy functions for image denoising which combine a quadratic data-fidelity term and a regularization term, where the properties of the latter are determined by a used potential function. Many potential functions are suggested for different purposes in the literature. We compare the denoising performance achieved by ten different potential functions. Several methods for efficient minimization of regularized energy functions exist. Most are only applicable to particular choices of potential functions, however. To enable a comparison of all the observed potential functions, we propose to minimize the objective function using a spectral gradient approach; spectral gradient methods put very weak restrictions on the used potential function. We present and evaluate the performance of one spectral conjugate gradient and one cyclic spectral gradient algorithm, and conclude from experiments that both are well suited for the task. We compare the performance with three total variation-based state-of-the-art methods for image denoising. From the empirical evaluation, we conclude that denoising using the Huber potential (for images degraded by higher levels of noise; signal-to-noise ratio below 10 dB) and the Geman and McClure potential (for less noisy images), in combination with the spectral conjugate gradient minimization algorithm, shows the overall best performance

  2. Bigravity from gradient expansion

    International Nuclear Information System (INIS)

    Yamashita, Yasuho; Tanaka, Takahiro

    2016-01-01

    We discuss how the ghost-free bigravity coupled with a single scalar field can be derived from a braneworld setup. We consider DGP two-brane model without radion stabilization. The bulk configuration is solved for given boundary metrics, and it is substituted back into the action to obtain the effective four-dimensional action. In order to obtain the ghost-free bigravity, we consider the gradient expansion in which the brane separation is supposed to be sufficiently small so that two boundary metrics are almost identical. The obtained effective theory is shown to be ghost free as expected, however, the interaction between two gravitons takes the Fierz-Pauli form at the leading order of the gradient expansion, even though we do not use the approximation of linear perturbation. We also find that the radion remains as a scalar field in the four-dimensional effective theory, but its coupling to the metrics is non-trivial.

  3. Computational strain gradient crystal plasticity

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Kysar, Jeffrey W.

    2014-01-01

    A numerical method for viscous strain gradient crystal plasticity theory is presented, which incorporates both energetic and dissipative gradient effects. The underlying minimum principles are discussed as well as convergence properties of the proposed finite element procedure. Three problems...... of plane crystal plasticity are studied: pure shear of a single crystal between rigid platens as well as plastic deformation around cylindrical voids in hexagonal close packed and face centered cubic crystals. Effective in-plane constitutive slip parameters for plane strain deformation of specifically...... oriented face centered cubic crystals are developed in terms of the crystallographic slip parameters. The effect on geometrically necessary dislocation structures introduced by plastic deformation is investigated as a function of the ratio of void radius to plasticity length scale....

  4. A flexoelectric theory with rotation gradient effects for elastic dielectrics

    International Nuclear Information System (INIS)

    Anqing, Li; Shenjie, Zhou; Lu, Qi; Xi, Chen

    2016-01-01

    In this paper, a general flexoelectric theory in the framework of couple stress theory is proposed for isotropic dielectrics, in which the rotation gradient and the polarization gradient are involved to represent the nonlocal mechanical and electrical effects, respectively. The present flexoelectric theory shows only the anti-symmetric part of rotation gradient can induce polarization, while the symmetric part of rotation gradient cannot induce polarization in isotropic dielectrics. The electrostatic stress is obtained naturally in the governing equations and boundary conditions in terms of the variational principle, which is composed of two parts: the Maxwell stress corresponding to the polarization and the remainder relating to the polarization gradient. The current theory is able to account for the effects of size, direct and inverse flexoelectricities, and electrostatic force. To illustrate this theory, a simple application of Bernoulli–Euler cantilever beam is discussed. The numerical results demonstrate neither the higher-order constant l 1 nor the higher-order constant l 2 associated with the symmetric and anti-symmetric parts of rotation gradient, respectively, can be ignored in the flexoelectric theory. In addition, the induced deflection increases as the increase of the flexoelectric coefficient. The polarization is no longer constant and the potential is no longer linear along the thickness direction of beam because of the influence of polarization gradient. (paper)

  5. Prognostic value of brain proton MR spectroscopy and diffusion tensor imaging in newborns with hypoxic-ischemic encephalopathy treated by brain cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ancora, G. [Neonatal Intensive Care Unit, Department of Mother and Infant Infermi Hospital of Rimini, Rimini (Italy); Testa, C.; Tonon, C.; Manners, D.N.; Gramegna, L.L.; Lodi, R. [Department of Biomedical and Neuromotor Sciences University of Bologna, MR Functional Unit, Bologna (Italy); Grandi, S.; Sbravati, F.; Savini, S.; Corvaglia, L.T.; Faldella, G. [University of Bologna, Neonatology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Tani, G. [University of Bologna, Radiology Unit, Department of Woman, Child and Adolescent Health, Bologna (Italy); Malucelli, E. [University of Bologna, Department of Pharmacy and Biotechnologies, Bologna (Italy)

    2013-08-15

    MRI, proton magnetic resonance spectroscopy ({sup 1}H-MRS), and diffusion tensor imaging (DTI) have been shown to be of great prognostic value in term newborns with moderate-severe hypoxic-ischemic encephalopathy (HIE). Currently, no data are available on {sup 1}H-MRS and DTI performed in the subacute phase after hypothermic treatment. The aim of the present study was to assess their prognostic value in newborns affected by moderate-severe HIE and treated with selective brain cooling (BC). Twenty infants treated with BC underwent conventional MRI and {sup 1}H-MRS at a mean (SD) age of 8.3 (2.8) days; 15 also underwent DTI. Peak area ratios of metabolites and DTI variables, namely mean diffusivity (MD), axial and radial diffusivity, and fractional anisotropy (FA), were calculated. Clinical outcome was monitored until 2 years of age. Adverse outcome was observed in 6/20 newborns. Both {sup 1}H-MRS and DTI variables showed higher prognostic accuracy than conventional MRI. N-acetylaspartate/creatine at a basal ganglia localisation showed 100 % PPV and 93 % NPV for outcome. MD showed significantly decreased values in many regions of white and gray matter, axial diffusivity showed the best predictive value (PPV and NPV) in the genu of corpus callosum (100 and 91 %, respectively), and radial diffusivity was significantly decreased in fronto white matter (FWM) and fronto parietal (FP) WM. The decrement of FA showed the best AUC (0.94) in the FPWM. Selective BC in HIE neonates does not affect the early and accurate prognostic value of {sup 1}H-MRS and DTI, which outperform conventional MRI. (orig.)

  6. Tolman temperature gradients in a gravitational field

    OpenAIRE

    Santiago, Jessica; Visser, Matt

    2018-01-01

    Tolman's relation for the temperature gradient in an equilibrium self-gravitating general relativistic fluid is broadly accepted within the general relativity community. However, the concept of temperature gradients in thermal equilibrium continues to cause confusion in other branches of physics, since it contradicts naive versions of the laws of classical thermodynamics. In this paper we discuss the crucial role of the universality of free fall, and how thermodynamics emphasises the great di...

  7. Gradient Learning Algorithms for Ontology Computing

    Science.gov (United States)

    Gao, Wei; Zhu, Linli

    2014-01-01

    The gradient learning model has been raising great attention in view of its promising perspectives for applications in statistics, data dimensionality reducing, and other specific fields. In this paper, we raise a new gradient learning model for ontology similarity measuring and ontology mapping in multidividing setting. The sample error in this setting is given by virtue of the hypothesis space and the trick of ontology dividing operator. Finally, two experiments presented on plant and humanoid robotics field verify the efficiency of the new computation model for ontology similarity measure and ontology mapping applications in multidividing setting. PMID:25530752

  8. Gradient Learning Algorithms for Ontology Computing

    Directory of Open Access Journals (Sweden)

    Wei Gao

    2014-01-01

    Full Text Available The gradient learning model has been raising great attention in view of its promising perspectives for applications in statistics, data dimensionality reducing, and other specific fields. In this paper, we raise a new gradient learning model for ontology similarity measuring and ontology mapping in multidividing setting. The sample error in this setting is given by virtue of the hypothesis space and the trick of ontology dividing operator. Finally, two experiments presented on plant and humanoid robotics field verify the efficiency of the new computation model for ontology similarity measure and ontology mapping applications in multidividing setting.

  9. Inner ear malformations in patients with sensorineural heating loss: detection with gradient-echo (3DFT-CISS) MRI

    Energy Technology Data Exchange (ETDEWEB)

    Casselman, J.W. [Dept. of Radiology, A.Z. St.-Jan Brugge, Bruges (Belgium); Kuhweide, R. [Dept. of Otorhinolaryngology, A.Z. St.-Jan Brugge, Bruges (Belgium); Ampe, W. [Dept. of Otorhinolaryngology, A.Z. St.-Jan Brugge, Bruges (Belgium); D`Hont, G.D. [Dept. of Otorhinolaryngology, A.Z. St.-Jan Brugge, Bruges (Belgium); Offeciers, E.F. [ENT Dept., Sint-Augustinus Medical Inst., Univ. of Antwerp (Belgium); Faes, W.K. [Dept. of Radiology, A.Z. St.-Jan Brugge, Bruges (Belgium); Pattyn, G. [Dept. of Radiology, A.Z. St.-Jan Brugge, Bruges (Belgium)

    1996-04-01

    The sensitivity of different MRI sequences in the detection of inner ear malformations in patients presenting with sensorineural hearing loss (SNHL) and/or vertigo was evaluated. We studied 650 patients presenting with SNHL and/or vertigo, clinically not suspected of having inner ear malformations. The sensitivity of T1-weigted, Gd-enhanced T1-weighted and (when available) T2-weighted spin-echo images, and three-dimensional Fourier transformation-constructive interference in steady state (3DFT-CISS) gradient-echo images, to unexpected malformations was assessed. Inner ear malformations were found in 15 (2.3%) of these patients. Enlargement of the endolymphatic duct and sac was the most frequent malformation, found in 11 patients. The 3DFT-CISS images showed all lesions; the other sequences were less sensitive and the pathology was missed, partially or only retrospectively seen in 11 of the 15 patients. Therefore, in addition to the routine unenhanced and Gd-enhanced T1-weighted and T2-weighted images, thin gradient-echo (3DFT-CISS) images are necessary to detect all clinically unexpected inner ear malformations in patients presenting with vertigo and/or SNHL. (orig.)

  10. Inner ear malformations in patients with sensorineural heating loss: detection with gradient-echo (3DFT-CISS) MRI

    International Nuclear Information System (INIS)

    Casselman, J.W.; Kuhweide, R.; Ampe, W.; D'Hont, G.D.; Offeciers, E.F.; Faes, W.K.; Pattyn, G.

    1996-01-01

    The sensitivity of different MRI sequences in the detection of inner ear malformations in patients presenting with sensorineural hearing loss (SNHL) and/or vertigo was evaluated. We studied 650 patients presenting with SNHL and/or vertigo, clinically not suspected of having inner ear malformations. The sensitivity of T1-weigted, Gd-enhanced T1-weighted and (when available) T2-weighted spin-echo images, and three-dimensional Fourier transformation-constructive interference in steady state (3DFT-CISS) gradient-echo images, to unexpected malformations was assessed. Inner ear malformations were found in 15 (2.3%) of these patients. Enlargement of the endolymphatic duct and sac was the most frequent malformation, found in 11 patients. The 3DFT-CISS images showed all lesions; the other sequences were less sensitive and the pathology was missed, partially or only retrospectively seen in 11 of the 15 patients. Therefore, in addition to the routine unenhanced and Gd-enhanced T1-weighted and T2-weighted images, thin gradient-echo (3DFT-CISS) images are necessary to detect all clinically unexpected inner ear malformations in patients presenting with vertigo and/or SNHL. (orig.)

  11. Preprocessing of gravity gradients at the GOCE high-level processing facility

    Science.gov (United States)

    Bouman, Johannes; Rispens, Sietse; Gruber, Thomas; Koop, Radboud; Schrama, Ernst; Visser, Pieter; Tscherning, Carl Christian; Veicherts, Martin

    2009-07-01

    One of the products derived from the gravity field and steady-state ocean circulation explorer (GOCE) observations are the gravity gradients. These gravity gradients are provided in the gradiometer reference frame (GRF) and are calibrated in-flight using satellite shaking and star sensor data. To use these gravity gradients for application in Earth scienes and gravity field analysis, additional preprocessing needs to be done, including corrections for temporal gravity field signals to isolate the static gravity field part, screening for outliers, calibration by comparison with existing external gravity field information and error assessment. The temporal gravity gradient corrections consist of tidal and nontidal corrections. These are all generally below the gravity gradient error level, which is predicted to show a 1/ f behaviour for low frequencies. In the outlier detection, the 1/ f error is compensated for by subtracting a local median from the data, while the data error is assessed using the median absolute deviation. The local median acts as a high-pass filter and it is robust as is the median absolute deviation. Three different methods have been implemented for the calibration of the gravity gradients. All three methods use a high-pass filter to compensate for the 1/ f gravity gradient error. The baseline method uses state-of-the-art global gravity field models and the most accurate results are obtained if star sensor misalignments are estimated along with the calibration parameters. A second calibration method uses GOCE GPS data to estimate a low-degree gravity field model as well as gravity gradient scale factors. Both methods allow to estimate gravity gradient scale factors down to the 10-3 level. The third calibration method uses high accurate terrestrial gravity data in selected regions to validate the gravity gradient scale factors, focussing on the measurement band. Gravity gradient scale factors may be estimated down to the 10-2 level with this

  12. Ion temperature gradient mode driven solitons and shocks

    Science.gov (United States)

    Zakir, U.; Adnan, Muhammad; Haque, Q.; Qamar, Anisa; Mirza, Arshad M.

    2016-04-01

    Ion temperature gradient (ITG) driven solitons and shocks are studied in a plasma having gradients in the equilibrium number density and equilibrium ion temperature. In the linear regime, it is found that the ion temperature and the ratio of the gradient scale lengths, ηi=Ln/LT , affect both the real frequency and the growth rate of the ITG driven wave instability. In the nonlinear regime, for the first time we derive a Korteweg de Vries-type equation for the ITG mode, which admits solitary wave solution. It is found that the ITG mode supports only compressive solitons. Further, it is noticed that the soliton amplitude and width are sensitive to the parameter ηi=Ln/LT . Second, in the presence of dissipation in the system, we obtain a Burger type equation, which admits the shock wave solution. This work may be useful to understand the low frequency electrostatic modes in inhomogeneous electron-ion plasma having density and ion temperature gradients. For illustration, the model has been applied to tokamak plasma.

  13. Geothermal gradients in Iraqi Kurdistan deduced from bottom hole temperatures

    Directory of Open Access Journals (Sweden)

    Rzger A. Abdula

    2017-09-01

    Full Text Available Bottom hole temperature (BHT data from 12 oil wells in Iraqi Kurdistan were used to obtain the thermal trend of Iraqi Kurdistan. Due to differences in thermal conductivity of rocks and groundwater movement, variations in geothermal gradients were observed. The highest geothermal gradient (29.2 °C/km was found for well Taq Taq-8 in the Low Folded Zone (central part of the area. The lowest geothermal gradients (14.9 °C/km were observed for well Bekhme-1 in the High Folded Zone (northern and northeastern parts of the area. The average regional geothermal gradient for Iraqi Kurdistan is 21 °C/km.

  14. Application of the conjugate-gradient method to ground-water models

    Science.gov (United States)

    Manteuffel, T.A.; Grove, D.B.; Konikow, Leonard F.

    1984-01-01

    The conjugate-gradient method can solve efficiently and accurately finite-difference approximations to the ground-water flow equation. An aquifer-simulation model using the conjugate-gradient method was applied to a problem of ground-water flow in an alluvial aquifer at the Rocky Mountain Arsenal, Denver, Colorado. For this application, the accuracy and efficiency of the conjugate-gradient method compared favorably with other available methods for steady-state flow. However, its efficiency relative to other available methods depends on the nature of the specific problem. The main advantage of the conjugate-gradient method is that it does not require the use of iteration parameters, thereby eliminating this partly subjective procedure. (USGS)

  15. Generation of tunable and pulsatile concentration gradients via microfluidic network

    KAUST Repository

    Zhou, Bingpu

    2014-06-04

    We demonstrate a compact Polydimethylsiloxane microfluidic chip which can quickly generate ten different chemical concentrations simultaneously. The concentration magnitude of each branch can be flexibly regulated based on the flow rate ratios of the two injecting streams. The temporal/pulsatile concentration gradients are achieved by integrating on-chip pneumatic actuated valves controlled by the external signals. The temporal concentration gradients can also be tuned precisely by varying applied frequency and duty cycle of the trigger signal. It is believed that such microdevice will be potentially used for some application areas of producing stable chemical gradients as well as allowing fast, pulsatile gradient transformation in seconds.

  16. Thermal-gradient migration of brine inclusions in salt crystals

    International Nuclear Information System (INIS)

    Yagnik, S.K.

    1982-09-01

    It has been proposed that high-level nuclear waste be disposed in a geologic repository. Natural-salt deposits, which are being considered for this purpose, contain a small volume fraction of water in the form of brine inclusions distributed throughout the salt. Radioactive-decay heating of the nuclear wastes will impose a temperature gradient on the surrounding salt which mobilizes the brine inclusions. Inclusions filled completely with brine migrate up the temperature gradient and eventually accumulate brine near the buried waste forms. The brine may slowly corrode or degrade the waste forms which is undesirable. In this work, thermal gradient migration of both all-liquid and gas-liquid inclusions was experimentally studied in synthetic single crystals of NaCl and KCl using a hot-stage attachment to an optical microscope which was capable of imposing temperature gradients and axial compressive loads on the crystals. The migration velocities of the inclusions were found to be dependent on temperature, temperature gradient, and inclusion shape and size. The velocities were also dictated by the interfacial mass transfer resistance at brine/solid interface. This interfacial resistance depends on the dislocation density in the crystal, which in turn, depends on the axial compressive loading of the crystal. At low axial loads, the dependence between the velocity and temperature gradient is non-linear.At high axial loads, however, the interfacial resistance is reduced and the migration velocity depends linearly on the temperature gradient. All-liquid inclusions filled with mixed brines were also studied. For gas-liquid inclusions, three different gas phases (helium, air and argon) were compared. Migration studies were also conducted on single crystallites of natural salt as well as in polycrystalline natural salt samples. The behavior of the inclusions at large angle grain boundaries was observed. 35 figures, 3 tables

  17. Thermal gradient migration of brine inclusions in salt crystals

    International Nuclear Information System (INIS)

    Yagnik, S.K.

    1982-01-01

    Natural salt deposits, which are being considered for high-level nuclear wastes repositories, contain a small volume fraction of water in the form of brine inclusions distributed throughout the salt. Radioactive decay heating of the nuclear wastes will impose a temperature gradient on the surrounding salt which mobilizes the brine inclusions. Inclusions filled completely with brine (the all-liquid inclusions) migrate up the temperature gradient and eventually accumulate brine near the buried waste forms. The brine may slowly corrode or degrade the waste forms which is undesirable. In the present work, thermal gradient migration of both all-liquid and gas-liquid inclusions was experimentally studied in synthetic single crystals of NaCl and KCl using a hot-stage attachment to an optical microscope which was capable of imposing temperature gradients and axial compressive loads on the crystals. The migration velocities of the inclusions were found to be dependent on temperature, temperature gradient, and inclusion shape and size. The velocities were also dictated by the interfacial mass transfer resistance at brine/solid interface. This interfacial resistance depends on the dislocation density in the crystal, which in turn, depends on the axial compressive loading of the crystal. At low axial loads, the dependence between the velocity and temperature gradient is nonlinear. At high axial loads, however, the interfacial resistance is reduced and the migration velocity depends linearly on the temperature gradient. All-liquid inclusions filled with mixed brines were also studied. For gas-liquid inclusions, three different gas phases (helium, air and argon) were compared. Migration studies were also conducted on single crystallites of natural salt as well as in polycrystalline natural salt samples. The behavior of the inclusions at large angle grain boudaries was observed

  18. Main Achievements 2003-2004 - Interdisciplinary Research - Applications of nuclear methods to biomedical physics, environmental biology, environmental physics, and medical physics - Magnetic Resonance Diffusion Tensor

    International Nuclear Information System (INIS)

    2005-01-01

    Magnetic Resonance Diffusion Tensor Imaging in the human cervical spinal cord, using an in-house developed DW-EPI sequence in the axial plane, was implemented on a 1.5 T SIGNA ECHO-PLUS GE system of the Silesian Imaging Centre HELIMED, tested on 30 volunteers to gather reference data, and used on patients with cervical spinal cord traumatic injury. Original software was developed to analyse data from DTI experiments. This work is performed in collaboration with Collegium Medicum UJ and Silesian Medical University. Special gradient coils capable of delivering gradients up 500 mT/m, a RF birdcage coil and a life-support system including temperature regulation and monitoring were designed and constructed to do MRI on transgenic mouse heart. A fast MRI cine-like FLASH sequence based on gradient echo was developed. Experiments are now under way, in collaboration with the Department of Pharmacology of the Collegium Medicum, Jagiellonian University to test heart-protecting drugs

  19. Conditioning the full-waveform inversion gradient to welcome anisotropy

    KAUST Repository

    Alkhalifah, Tariq Ali

    2015-04-23

    Multiparameter full-waveform inversion (FWI) suffers from complex nonlinearity in the objective function, compounded by the eventual trade-off between the model parameters. A hierarchical approach based on frequency and arrival time data decimation to maneuver the complex nonlinearity associated with this problem usually falls short in anisotropic media. In place of data decimation, I use a model gradient filter approach to access the parts of the gradient more suitable to combat the potential nonlinearity and parameter trade-off. The filter is based on representing the gradient in the time-lag normalized domain, in which small scattering-angles of the gradient update are initially muted out. The model update hierarchical filtering strategy include applying varying degrees of filtering to the different anisotropic parameter updates, a feature not easily accessible to simple data decimation. Using FWI and reflection-based FWI, when the modeled data are obtained with the single-scattering theory, allows access to additional low model wavenumber components. Combining such access to wavenumbers with scattering-angle filters applied to the individual parameter gradients allows for multiple strategies to avoid complex FWI nonlinearity as well as the parameter trade-off.

  20. W-Cu gradient materials - processing, properties and application possibilities

    International Nuclear Information System (INIS)

    Joensson, M.; Kieback, B.

    2001-01-01

    The functionally graded material (FGM) of tungsten with its high thermal and mechanical resistance and copper with its very high thermal and electrical conductivity and ductility expands the application fields of this material in the direction of extreme demands such as plasma facing components in fusion reactors. The PM-production of W-Cu-gradients recommends itself because of the possibility to form the gradient by the mixing of powder components, but is also demanding because of the differences in their sintering behavior and thermal expansions. W-Gu-gradient samples of different concentration profiles have been formed in layers by powder stacking in a die and continuously by centrifugal powder forming. The consolidation routes were determined by the concentration areas of the gradients and encompass liquid phase sintering, pressure assisted solid phase sintering and the application of coated Tungsten powder and sintering additives. The microstructure and the concentration profiles of the samples have been investigated metaliographically and by EDX. The influence of processing and the gradient profile of the properties have been characterized by TRS and the investigation of residual thermal stresses by neutron diffraction. (author)