WorldWideScience

Sample records for clean water healthcare

  1. An international survey of cleaning and disinfection practices in the healthcare environment.

    Science.gov (United States)

    Kenters, Nikki; Gottlieb, Thomas; Hopman, Joost; Mehtar, Shaheen; Schweizer, Marin L; Tartari, Ermira; Huijskens, E G W; Voss, Andreas

    2018-05-14

    Antimicrobial resistance has become an urgent global health priority. Basic hygiene practices and cleaning and disinfection of the hospital environment are key in preventing pathogen cross-transmission. To our knowledge no studies have assessed the worldwide differences in cleaning and disinfection practices in healthcare facilities. The electronic survey described here was developed in order to evaluate differences in healthcare facility cleaning practices around the world. The International Society of Antimicrobial Chemotherapy (ISAC, formerly ISC), Infection Prevention and Control work group developed a survey with 30 multiple-choice questions. The questions were designed to assess the current cleaning practices in healthcare settings around the world. A total of 110 healthcare professionals, representing 23 countries participated in the online survey. In 96% of the facilities a written cleaning policy was present. Training of cleaning staff occurred in 70% of the facilities at the start of employment. Cleaning practices and monitoring of these practices varied. In summary, the survey enabled assessment and recognition of widely differing global practices in approaches to environmental cleaning and disinfection. Development of guideline recommendations for cleaning and disinfection could improve practices and set minimum standards worldwide. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Microbial water quality in clean water tanks following inspection and cleaning

    DEFF Research Database (Denmark)

    Christensen, Sarah Christine Boesgaard; Esbjørn, Anne; Mollerup, Finn

    Increased bacterial counts are often registered in drinking water leaving clean water tanks after the tanks have been emptied, inspected and cleaned by flushing. To investigate the reason for the increased bacterial concentrations and consequently limit it, samples from two clean water tanks befo...... start-up of the tanks, which may indicate that a substantial part of the bacteria in the drinking water leaving the tanks originated from the sand filter. This was supported by 16S DNA analyses....

  3. Reactor water clean-up device

    International Nuclear Information System (INIS)

    Tanaka, Koji; Egashira, Yasuo; Shimada, Fumie; Igarashi, Noboru.

    1983-01-01

    Purpose: To save a low temperature reactor water clean-up system indispensable so far and significantly simplify the system by carrying out the reactor water clean-up solely in a high temperature reactor water clean-up system. Constitution: The reactor water clean-up device comprises a high temperature clean-up pump and a high temperature adsorption device for inorganic adsorbents. The high temperature adsorption device is filled with amphoteric ion adsorbing inorganic adsorbents, or amphoteric ion adsorbing inorganic adsorbents and anionic adsorbing inorganic adsorbents. The reactor water clean-up device introduces reactor water by the high temperature clean-up pump through a recycling system to the high temperature adsorption device for inorganic adsorbents. Since cations such as cobalt ions and anions such as chlorine ions in the reactor water are simultaneously removed in the device, a low temperature reactor water clean-up system which has been indispensable so far can be saved to realize the significant simplification for the entire system. (Seki, T.)

  4. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility

    Science.gov (United States)

    Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.

    2018-01-01

    Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951

  5. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.

    Science.gov (United States)

    Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C

    2018-01-01

    Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

  6. Pool water cleaning facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro [Hitachi Ltd., Tokyo (Japan); Asano, Takashi

    1998-05-29

    Only one system comprising a suppression poor water cleaning system (SPCU) and a filtration desalting tower (F/D) is connected for a plurality of nuclear power plants. Pipelines/valves for connecting the one system of the SPCU pump, the F/D and the plurality of nuclear power plants are disposed, and the system is used in common with the plurality of nuclear power plants. Pipelines/valves for connecting a pipeline for passing SP water to the commonly used SPCU pump and a skimmer surge tank are disposed, and fuel pool water is cooled and cleaned by the commonly used SPCU pump and the commonly used F/D. The number of SPCU pumps and the F/D facilities can be reduced, and a fuel pool water cooling operation mode and a fuel pool water cleaning operation mode which were conducted by an FPC pump so far are conducted by the SPCU pump. (N.H.)

  7. 14 CFR 1260.34 - Clean air and water.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319...

  8. Clean Water Action Plan: Restoring and protecting America`s waters

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    On October 18, 1997, the 25th anniversary of the enactment of the Clean Water Act, the Vice President called for a renewed effort to restore and protect water quality. The Vice President asked that the Secretary of Agriculture and the Administrator of the Environmental Protection Agency (EPA), working with other affected agencies, develop a Clean Water Action Plan that builds on clean water successes and addresses three major goals: (1) enhanced protection from public health threats posed by water pollution; (2) more effective control of polluted runoff; and (3) promotion of water quality protection on a watershed basis.

  9. Impact of emerging clean vehicle system on water stress

    International Nuclear Information System (INIS)

    Cai, Hua; Hu, Xiaojun; Xu, Ming

    2013-01-01

    Graphical abstract: Display Omitted - Highlights: • Clean vehicles may increase US water consumption up to 2810 billion gallons/year. • Large-scale clean vehicle adoption could lead to severe regional water stress. • Fuel choice for clean vehicle is crucial in minimizing regional water stress. • Regional optimization illustrated the importance of regional consideration. - Abstract: While clean vehicles (i.e., vehicles powered by alternative fuels other than fossil fuels) offer great potential to reduce greenhouse gas emissions from gasoline-based vehicles, the associated impact on water resources has not yet been fully assessed. This research provides a systematic evaluation of the impact of a fully implemented clean vehicle system on national and state-level water demand and water stress. On the national level, based on existing policies, transitioning the current gasoline-based transportation into one with clean vehicles will increase national annual water consumption by 1950–2810 billion gallons of water, depending on the market penetration of electric vehicles. On the state level, variances of water efficiency in producing different fuels are significant. The fuel choice for clean vehicle development is especially crucial for minimizing water stress increase in states with already high water stress, high travel demands, and significant variations in water efficiency in producing different alternative fuels. Current development of clean vehicle infrastructure, however, has not reflected these state-level variations. This study takes an optimization approach to further evaluate impacts on state-level water stress from a fully implemented clean vehicle system and identified potential roles (fuel producer or consumer) states may play in real world clean vehicle development scenario. With an objective of minimizing overall water stress impact, our optimization model aims to provide an analytical framework to better assess impacts on state-level water

  10. Clean Water Act

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data represent geographic terms used within the Clean Water Act (CWA). The CWA establishes the basic structure for regulating the addition of pollutants...

  11. In-Water Hull Cleaning & Filtration System

    Science.gov (United States)

    George, Dan

    2015-04-01

    Dan George R & D Mining Technology LinkedIn GRD Franmarine have received the following prestigious awards in 2014 for their research & development of an in-water hull cleaning and filtration system "The Envirocart: Golden Gecko Award for Environmental Excellence; WA Innovator of the Year - Growth Sector; Department of Fisheries - Excellence in Marine Biosecurity Award - Innovation Category; Lloyd's List Asia Awards - Environmental Award; The Australian Innovation Challenge - Environment, Agriculture and Food Category; and Australian Shipping and Maritime Industry Award - Environmental Transport Award. The Envirocart developed and patented by GRD Franmarine is a revolutionary new fully enclosed capture and containment in-water hull cleaning technology. The Envirocart enables soft Silicon based antifouling paints and coatings containing pesticides such as Copper Oxide to be cleaned in situ using a contactless cleaning method. This fully containerised system is now capable of being deployed to remote locations or directly onto a Dive Support Vessel and is rated to offshore specifications. This is the only known method of in-water hull cleaning that complies with the Department of Agriculture Fisheries and Forestry (DAFF) and Department of Fisheries WA (DoF) Guidelines. The primary underwater cleaning tool is a hydraulically powered hull cleaning unit fitted with rotating discs. The discs can be fitted with conventional brushes for glass or epoxy based coatings or a revolutionary new patented blade system which can remove marine biofouling without damaging the antifouling paint (silicone and copper oxide). Additionally there are a patented range of fully enclosed hand cleaning tools for difficult to access niche areas such as anodes and sea chests, providing an innovative total solution that enables in-water cleaning to be conducted in a manner that causes no biological risk to the environment. In full containment mode or when AIS are present, material is pumped

  12. Moderator clean-up system in a heavy water reactor

    International Nuclear Information System (INIS)

    Sasada, Yasuhiro; Hamamura, Kenji.

    1983-01-01

    Purpose: To decrease the fluctuation of the poison concentration in heavy water moderator due to a heavy water clean-up system. Constitution: To a calandria tank filled with heavy water as poison-containing moderators, are connected both end of a pipeway through which heavy water flows and to which a clean-up device is provided. Strongly basic resin is filled within the clean-up device and a cooler is disposed to a pipeway at the upstream of the clean-up device. In this structure, the temperature of heavy water at the inlet of the clean-up device at a constant level between the temperature at the exit of the cooler and the lowest temperature for the moderator to thereby decrease the fluctuation in the poison concentration in the heavy water moderator due to the heavy water clean-up device. (Moriyama, K.)

  13. Cleaning the feed-water pipeline internal surfaces

    International Nuclear Information System (INIS)

    Podkopaev, V.A.

    1984-01-01

    The procedure of cleaning the feed-water pipeline internal surfaces at the Chernobylsk-4 power unit is described. Cleaning was conducted in five stages. Pipelines were cleaned from mechanical impurities at the first stage. At the second stage the pipelines were washing by water heated up to 80 deg C. At the third stage nitric acid was added to 95-100 deg C water the acid concentration in the circuit = 60 mg/l, purification period = 14 h. At the fourth stage hydrogen peroxide was added to the circuit at 95-100 deg C (the solution concentration was equal to 5-6 mg/l, the solution stayed in the circuit for 1 h 20 min). At the fifth stage sodium nitrite concentrated to 20 mg/l was introduced to the circuit in 75 minutes; this promoted strengthening of the oxide layer in the circuit on the base of nitric acid and hydrogen peroxide. Data on the water acidity in the circuit, water electric conductivity and iron concentration after the fourth stage and on completion of the circuit cleaning are presented. The described method of cleaning enables to save scarce reagents and use cheaper ones

  14. Cleaning the feed-water pipeline internal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Podkopaev, V.A.

    1984-12-01

    The procedure of cleaning the feed-water pipeline internal surfaces at the Chernobylsk-4 power unit is described. Cleaning was conducted in five stages. Pipelines were cleaned from mechanical impurities at the first stage. At the second stage the pipelines were washed by water heated up to 80 deg C. At the third stage nitric acid was added to 95-100 deg C water with the acid concentration in the circuit = 60 mg/l, purification period = 14 h. At the fourth stage hydrogen peroxide was added to the circuit at 95-100 deg C (the solution concentration was equal to 5-6 mg/l, the solution stayed in the circuit for 1 h 20 min). At the fifth stage sodium nitrite concentrated to 20 mg/l was introduced to the circuit in 75 minutes; this promoted strengthening of the oxide layer in the circuit on the base of nitric acid and hydrogen peroxide. Data on the water acidity in the circuit, water electric conductivity and iron concentration after the fourth stage and on completion of the circuit cleaning are presented. The described method of cleaning enables to save scarce reagents and use cheaper ones.

  15. Nuclear waste water being cleaned in Paldinski

    International Nuclear Information System (INIS)

    Lahtinen, A.

    1995-01-01

    The cleaning of nuclear waste water in the former military base of Paldiski, Estonia, has started with Finnish assistance. During the Soviet era, Paldiski served as a site for training nuclear submarine crews. Spent fuel has already been removed from the two nuclear reactors on the base. The volume of water to be cleaned totals some 450 cubic metres. The work is estimated to take till May 1995. The filtering technique used for cleaning has been developed in cooperation by IVO International and the Department of Radiochemistry of the University of Helsinki. The project is one aspect of an extensive international cooperation programme for reducing environmental hazards arising from the base. The experience of the cleaning obtained so far has been positive. In the first water tank, filtering reduced the cesium activity of waste water from 1,500 becquerels to less than one becquerel. Two water tanks, however, have bottom sediment that probably cannot be treated during the present project. (orig.)

  16. Solar photocatalytic cleaning of polluted water

    International Nuclear Information System (INIS)

    Bockelmann, D.

    1994-01-01

    Alternatively to biological, physical and chemical methods of waste water cleaning, photocatalysis can be employed. In this residue-free method, titanium dioxide particles are brought into contact with polluted water as photocatalysts. Under UV irradiation at wave-lengths below 400 nm, change carriers are generated in the semiconductor particles that act so intensely oxidizing as to completely degrade almost all organic pollutants in waste water. In this process, the ultra-violet part of the solar spectrum can be harnessed to generate oxidation equivalents. Thus, solar photocatalytic waste water cleaning is excellently suited for developing countries. (BWI) [de

  17. Processing method for cleaning water waste from cement kneader

    International Nuclear Information System (INIS)

    Soda, Kenzo; Fujita, Hisao; Nakajima, Tadashi.

    1990-01-01

    The present invention concerns a method of processing cleaning water wastes from a cement kneader in a case of processing liquid wastes containing radioactive wastes or deleterious materials such as heavy metals by means of cement solidification. Cleaning waste wastes from the kneader are sent to a cleaning water waste tank, in which gentle stirring is applied near the bottom and sludges are retained so as not to be coagulated. Sludges retained at the bottom of the cleaning water waste tank are sent after elapse of a predetermined time and then kneaded with cements. Thus, since the sludges in the cleaning water are solidified with cement, inhomogenous solidification products consisting only of cleaning sludges with low strength are not formed. The resultant solidification product is homogenous and the compression strength thereof reaches such a level as capable of satisfying marine disposal standards required for the solidification products of radioactive wastes. (I.N.)

  18. Hawaii Clean Water Branch (CWB) Beach Water Quality Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Exposure to sewage contaminated recreational waters may cause gastrointestinal illnesses in swimmers. The State of Hawaii Department of Health (HIDOH) Clean Water...

  19. Using Ecosystem Function in the Clean Water Act

    Science.gov (United States)

    Clean, fresh water is one of our most precious natural resources. The Clean Water Act was enacted to control pollution. It has been highly successful in controlling pollution at the point of contamination. Yet, there are still areas where vast improvements need to be made. Enviro...

  20. TORR system polishes oily water clean

    International Nuclear Information System (INIS)

    Mowers, J.

    2002-01-01

    The TORR (total oil recovery and remediation) system utilizes a specially patented polymer material, similar to styrofoam, which is used to get rid of non-soluble hydrocarbons from water. An application in Fort Smith, Northwest Territories, is described where it was used to recover diesel oil, which had been seeping into the groundwater over a period of 20 years. About 100,000 gallons of heating oil had leached into the water; TORR removed the non-soluble hydrocarbons, while another piece of equipment removed the soluble portions. After treatment the water tested consistently at non-detectable levels and was clean enough to be discharged into the town's sewer system. The system is considered ideal for oil spills clean-up underground, onshore, or the open sea, but it also has many potentially useful applications in industrial and oilfield applications. Water used in steam injection and water floods to produce heavy oil and SAGD applications are some of the obvious ones that come to mind. Cleaning up the huge tailings ponds at the mining and processing of oil sands, and removing diluent from water that is used to thin out bitumen in pipelines so that it can be transported to processing plants, are other promising areas of application. Several field trials to test the effectiveness of the system in these type of applications are scheduled for the summer and fall of 2002

  1. Technology: New Ways for Clean Water

    Science.gov (United States)

    Roberts, Amanda S.

    2012-01-01

    Water purification promotes healthy living. While the developing world is working to provide its citizens with future access to clean water sources, the demand for that water is a pressing need today. It should be understood that drinking water, sanitation, and hygiene are interwoven and are all necessary for the overall improved standard of…

  2. Emerging forward osmosis (FO) technologies and challenges ahead for clean water and clean energy applications

    KAUST Repository

    Chung, Tai-Shung; Li, Xue; Ong, Rui Chin; Ge, Qingchun; Wang, Honglei; Han, Gang

    2012-01-01

    The purpose of this short review is to share our understanding and perspectives with the chemical, environmental, water and osmotic power communities on FO processes in order to conduct meaningful R & D and develop effective and sustainable FO technologies for clean water and clean energy. © 2012 Elsevier Ltd. All rights reserved.

  3. Emerging forward osmosis (FO) technologies and challenges ahead for clean water and clean energy applications

    KAUST Repository

    Chung, Tai-Shung

    2012-08-01

    The purpose of this short review is to share our understanding and perspectives with the chemical, environmental, water and osmotic power communities on FO processes in order to conduct meaningful R & D and develop effective and sustainable FO technologies for clean water and clean energy. © 2012 Elsevier Ltd. All rights reserved.

  4. Bioinspired Bifunctional Membrane for Efficient Clean Water Generation.

    Science.gov (United States)

    Liu, Yang; Lou, Jinwei; Ni, Mengtian; Song, Chengyi; Wu, Jianbo; Dasgupta, Neil P; Tao, Peng; Shang, Wen; Deng, Tao

    2016-01-13

    Solving the problems of water pollution and water shortage is an urgent need for the sustainable development of modern society. Different approaches, including distillation, filtration, and photocatalytic degradation, have been developed for the purification of contaminated water and the generation of clean water. In this study, we explored a new approach that uses solar light for both water purification and clean water generation. A bifunctional membrane consisting of a top layer of TiO2 nanoparticles (NPs), a middle layer of Au NPs, and a bottom layer of anodized aluminum oxide (AAO) was designed and fabricated through multiple filtration processes. Such a design enables both TiO2 NP-based photocatalytic function and Au NP-based solar-driven plasmonic evaporation. With the integration of these two functions into a single membrane, both the purification of contaminated water through photocatalytic degradation and the generation of clean water through evaporation were demonstrated using simulated solar illumination. Such a demonstration should also help open up a new strategy for maximizing solar energy conversion and utilization.

  5. 77 FR 54909 - Clean Water Act: Availability of List Decisions

    Science.gov (United States)

    2012-09-06

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9724-6] Clean Water Act: Availability of List Decisions... notice announces EPA's decision to identify certain water quality limited waters and the associated pollutant to be listed pursuant to the Clean Water Act Section 303(d)(2) on New York's list of impaired...

  6. Assessed Clean Water Act 305(b) Water Sources of Impairment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Identifies the sources of impairment for assessed waters under the Clean Water Act 305(b) program. This view can be used for viewing the details at the assessment...

  7. 78 FR 20912 - Clean Water Act: Availability of List Decisions

    Science.gov (United States)

    2013-04-08

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9798-8] Clean Water Act: Availability of List Decisions.... SUMMARY: The Clean Water Act requires that States periodically submit, and EPA approve or disapprove... are not stringent enough to attain or maintain State water quality standards and for which total...

  8. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et seq...

  9. Clean Water Act Section 404 and Agriculture

    Science.gov (United States)

    The U.S. Department of Agriculture (USDA) and EPA have longstanding programs to promote water quality and broader environmental goals identified in both the Agriculture Act of 2014 and the Clean Water Act.

  10. Section 404 of the Clean Water Act

    Science.gov (United States)

    Information about the Clean Water Act permitting program for dredge or fill material into waters of the US, including roles, 401 certification of permits, state/tribal assumption of 404 program, mitigation requirements, regulations

  11. A self-cleaning underwater superoleophobic mesh for oil-water separation

    KAUST Repository

    Zhang, Lianbin; Zhong, Yujiang; Cha, Dong Kyu; Wang, Peng

    2013-01-01

    and inexpensive approaches for the cleaning-up of the oily pollution in water system. In this study, a self-cleaning underwater superoleophobic mesh that can be used for oil-water separation is prepared by the layer-by-layer (LbL) assembly of sodium silicate

  12. The applied technologies to access clean water for remote communities

    Science.gov (United States)

    Rabindra, I. B.

    2018-01-01

    A lot of research is done to overcome the remote communities to access clean water, yet very little is utilized and implemented by the community. Various reasons can probably be made for, which is the application of research results is assessed less practical. The aims of this paper is seeking a practical approach, how to establish criteria for the design can be easier applied, at the proper locations, the simple construction, effectively producing a volume and quality of clean water designation. The methods used in this paper is a technological model assessment of treatment/filtering clean water produced a variety of previous research, to establish a model of appropriate technology for remote communities. Various research results collected from the study of literature, while the identification of opportunities and threats to its application is done using a SWOT analysis. This article discussion is looking for alternative models of clean water filtration technology from the previous research results, to be selected as appropriate technology, easily applied and bring of many benefits to the remote communities. The conclusions resulting from the discussion in this paper, expected to be used as the basic criteria of design model of clean water filtration technologies that can be accepted and applied effectively by the remote communities.

  13. Water, sanitation and hygiene in Jordan's healthcare facilities.

    Science.gov (United States)

    Khader, Yousef Saleh

    2017-08-14

    Purpose The purpose of this paper is to determine water availability, sanitation and hygiene (WSH) services, and healthcare waste management in Jordan healthcare facilities. Design/methodology/approach In total, 19 hospitals (15 public and four private) were selected. The WSH services were assessed in hospitals using the WSH in health facilities assessment tool developed for this purpose. Findings All hospitals (100 percent) had a safe water source and most (84.2 percent) had functional water sources to provide enough water for users' needs. All hospitals had appropriate and sufficient gender separated toilets in the wards and 84.2 percent had the same in outpatient settings. Overall, 84.2 percent had sufficient and functioning handwashing basins with soap and water, and 79.0 percent had sufficient showers. Healthcare waste management was appropriately practiced in all hospitals. Practical implications Jordan hospital managers achieved major achievements providing access to drinking water and improved sanitation. However, there are still areas that need improvements, such as providing toilets for patients with special needs, establishing handwashing basins with water and soap near toilets, toilet maintenance and providing sufficient trolleys for collecting hazardous waste. Efforts are needed to integrate WSH service policies with existing national policies on environmental health in health facilities, establish national standards and targets for the various healthcare facilities to increase access and improve services. Originality/value There are limited WSH data on healthcare facilities and targets for basic coverage in healthcare facilities are also lacking. A new assessment tool was developed to generate core WSH indicators and to assess WSH services in Jordan's healthcare facilities. This tool can be used by a non-WSH specialist to quickly assess healthcare facility-related WSH services and sanitary hazards in other countries. This tool identified some areas

  14. Chemical cleaning the service water system at a nuclear power plant

    International Nuclear Information System (INIS)

    Brice, T.O.; Glover, W.A.

    1994-01-01

    Chemical cleaning a large cooling water system in a nuclear power plant presented many unique problems. The selection, qualification, and performance of the cleaning process were done using a phased approach. The piping was inspected to determine the extent of the problem. Deposit samples were removed from the service water system pipe and tested in the laboratory to determine the most effective cleaning solvent for deposit removal. An engineering study was performed to define the design parameters required to implement the system-wide chemical cleaning

  15. Occupational radon expositions during cleaning processes of water reservoirs

    International Nuclear Information System (INIS)

    Hingmann, H.; Ehret, V.; Hegenbart, L.; Krieg, K.

    2002-01-01

    According to the new German ''Strahlenschutzverordnung'' (Radiation Protection Directive) the annual dose due to the exposition to radon has to be estimated for employees of water works. This includes employees of service companies. While the job of employees of water works usually covers a broad spectrum of different activities, employees of service companies may spend a considerable amount of time of their total working hours cleaning water reservoirs. This investigation is concerned with this type of employees. The radon exposition of one or more cleaning processes were determined by passive dosimeters. The mean radon concentration was calculated for the duration of the cleaning process. In some cases, members of the project team accompanied cleaning processes and performed stationary radon measurements on site. Sometimes, parallel to the passive dosimeters, electronic dosimeters were used to measure personal exposure. The results - and results from additional laboratory reference measurements - are compared. All results until January 2002 are considered. The project still goes on and will end in summer of 2002. Experiences made during this investigation are described in the end of this report. (orig.)

  16. Remote Water Lance Technology for Cleaning Waste Tanks

    International Nuclear Information System (INIS)

    Lehr, R.M.; Owen, J.R.; Mangold, F.E.

    2006-01-01

    This paper describes the use of remote water lances for cleaning sludge or solidified heel materials from waste tanks. S.A.Robotics has developed a long arm retrieval system to deploy ultra-high pressure water lances and vacuum recovery systems for tank cleanup operations. This system uses remote-operated telescoping long arms with light weight, high strength materials, innovative high capacity joint designs, and multiple degrees of freedom to deploy tank cleaning heads to all areas within the tanks. Arm designs can be scaled and adjusted to suit even the largest tanks. (authors)

  17. Service water chemical cleaning at River Bend gets results

    International Nuclear Information System (INIS)

    Brice, T.O.; Glover, W.A.

    1994-01-01

    The largest known Service Water System (SWS) chemical cleaning ever performed at a nuclear plant was successfully completed at, River Bend Station. Corrosion product buildup was observed during system inspections in the first operating cycle and the first refueling outage in 1987. Under deposit corrosion was followed with microbiologically influenced corrosion (MIC) occurring as a later stage under deposits. The heavy corrosion caused blockage of heat exchanger tubes, fouling of valve seats, and general flow blockage throughout the system. Various options were evaluated for restoring the SWS back to an acceptable long term operating condition. The large scale chemical cleaning performed arrested the corrosion by removing the deposits down to the bare metal surfaces and leaving behind a protective passivation layer. After the cleaning, the open recirculating SWS was converted to a closed system. The implementation of a molybdate/nitrate water treatment program with a copper corrosion inhibitor maintained at a high pH (8.5--10.5) has significantly reduced corrosion rates in the closed system. This should extend the life of the SWS piping for the remaining life of the plant. Several field tests were conducted to qualify the process and demonstrate its ability to achieve acceptable cleaning results prior to being used on a larger scale. In the summer of 1992, temporary and permanent modifications were installed to divide the SWS into two separate cleaning loops for the system wide cleaning. The SWS chemical was successfully performed and completed on schedule during the fourth refueling outage. Post cleaning inspections at various locations throughout the Service Water System showed the process to be very effective at complete deposit removal

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Published on May 5, 2017 This video for healthcare providers is intended to promote or encourage adherence ... role in their care by asking or reminding healthcare providers to clean their hands. See: https://www. ...

  19. Comparison of cleaning efficacy between in-use disinfectant and electrolysed water in an English residential care home.

    Science.gov (United States)

    Meakin, N S; Bowman, C; Lewis, M R; Dancer, S J

    2012-02-01

    Infection control in hospitals and care homes remains a key issue. They are regularly inspected regarding standards of hygiene, but visual assessment does not necessarily correlate with microbial cleanliness. Pathogens can persist in the inanimate environment for extended periods of time. This prospective study compared the effectiveness of a novel sanitizer containing electrolysed water, in which the active ingredient is stabilized hypochlorous acid (Aqualution™), with the effectiveness of the quaternary ammonium disinfectant in current use for microbial removal from hand-touch surfaces in a care home. The study had a two-period crossover design. Five surfaces were cleaned daily over a four-week period, with screening swabs taken before and after cleaning. Swabs were cultured in order to compare levels of surface microbial contamination [colony-forming units (cfu)/cm(2)] before and after cleaning with each product. Cleaning with electrolysed water reduced the mean surface bacterial load from 2.6 [interquartile range (IQR) 0.30-30.40] cfu/cm(2) to 0.10 (IQR 0.10-1.40) cfu/cm(2) [mean log(10) reduction factor 1.042, 95% confidence interval (CI) 0.79-1.30]. Cleaning with the in-use quaternary ammonium disinfectant increased the bacterial load from 0.90 (IQR 0.10-8.50) cfu/cm(2) to 93.30 (IQR 9.85-363.65) cfu/cm(2) (mean log(10) reduction -1.499, 95% CI -1.87 to -1.12) (P effective bacterial kill than the in-use quaternary ammonium disinfectant, which suggests that it may be useful as a surface sanitizer in environments such as care homes. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. EPA Office of Water (OW): Clean Watersheds Needs Survey NHDPlus Indexed Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Clean Watersheds Needs Survey (CWNS) is a comprehensive assessment of the capital needs to the water quality goals set in the Clean Water Act. Every four years,...

  1. Environmental cleaning and disinfection of patient areas

    Directory of Open Access Journals (Sweden)

    Michelle Doll

    2018-02-01

    Full Text Available The healthcare setting is predisposed to harbor potential pathogens, which in turn can pose a great risk to patients. Routine cleaning of the patient environment is critical to reduce the risk of hospital-acquired infections. While many approaches to environmental cleaning exist, manual cleaning supplemented with ongoing assessment and feedback may be the most feasible for healthcare facilities with limited resources.

  2. A self-cleaning underwater superoleophobic mesh for oil-water separation

    KAUST Repository

    Zhang, Lianbin

    2013-07-31

    Oil-water separation has recently become a global challenging task because of the frequent occurrence of oil spill accidents due to the offshore oil production and transportation, and there is an increasing demand for the development of effective and inexpensive approaches for the cleaning-up of the oily pollution in water system. In this study, a self-cleaning underwater superoleophobic mesh that can be used for oil-water separation is prepared by the layer-by-layer (LbL) assembly of sodium silicate and TiO2 nanoparticles on the stainless steel mesh. The integration of the self-cleaning property into the all-inorganic separation mesh by using TiO2 enables the convenient removal of the contaminants by ultraviolet (UV) illumination, and allows for the facile recovery of the separation ability of the contaminated mesh, making it promising for practial oil-water separation applications.

  3. Water cleaning by pulsed corona discharges

    NARCIS (Netherlands)

    Grabowski, L.R.; Veldhuizen, van E.M.; Rutgers, W.R.

    2004-01-01

    Direct electrical energization methods for water cleaning are under investigation in the framework of the ytriD-project1. The emphasis of the first stage of the project is optimization of the reactor configuration regarding the energy efficiency. A comparison is made between a batch reactor and an

  4. Clean Air Markets - Monitoring Surface Water Chemistry

    Science.gov (United States)

    Learn about how EPA uses Long Term Monitoring (LTM) and Temporily Integrated Monitoring of Ecosystems (TIME) to track the effect of the Clean Air Act Amendments on acidity of surface waters in the eastern U.S.

  5. The role of water in healthcare-associated infections.

    Science.gov (United States)

    Decker, Brooke K; Palmore, Tara N

    2013-08-01

    The aim is to discuss the epidemiology of infections that arise from contaminated water in healthcare settings, including Legionnaires' disease, other Gram-negative pathogens, nontuberculous mycobacteria, and fungi. Legionella can colonize a hospital water system and infect patients despite use of preventive disinfectants. Evidence-based measures are available for secondary prevention. Vulnerable patients can develop healthcare-associated infections with waterborne organisms that are transmitted by colonization of plumbing systems, including sinks and their fixtures. Room humidifiers and decorative fountains have been implicated in serious outbreaks, and pose unwarranted risks in healthcare settings. Design of hospital plumbing must be purposeful and thoughtful to avoid the features that foster growth and dissemination of Legionella and other pathogens. Exposure of patients who have central venous catheters and other invasive devices to tap water poses a risk for infection with waterborne pathogens. Healthcare facilities must conduct aggressive clinical surveillance for Legionnaires' disease and other waterborne infections in order to detect and remediate an outbreak promptly. Hand hygiene is the most important measure to prevent transmission of other Gram-negative waterborne pathogens in the healthcare setting.

  6. Environmental cleaning and disinfection of patient areas.

    Science.gov (United States)

    Doll, Michelle; Stevens, Michael; Bearman, Gonzalo

    2018-02-01

    The healthcare setting is predisposed to harbor potential pathogens, which in turn can pose a great risk to patients. Routine cleaning of the patient environment is critical to reduce the risk of hospital-acquired infections. While many approaches to environmental cleaning exist, manual cleaning supplemented with ongoing assessment and feedback may be the most feasible for healthcare facilities with limited resources. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. 78 FR 79692 - Clean Water Act; Contractor Access to Confidential Business Information

    Science.gov (United States)

    2013-12-31

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9904-94-OW] Clean Water Act; Contractor Access to... Transfer of Confidential Business Information to Contractor, Subcontractors, and Consultants. SUMMARY: The... contractors listed below require access to CBI submitted to EPA under Section 308 of the Clean Water Act (CWA...

  8. Separations Technology for Clean Water and Energy

    Energy Technology Data Exchange (ETDEWEB)

    Jarvinen, Gordon D [Los Alamos National Laboratory

    2012-06-22

    Providing clean water and energy for about nine billion people on the earth by midcentury is a daunting challenge. Major investments in efficiency of energy and water use and deployment of all economical energy sources will be needed. Separations technology has an important role to play in producing both clean energy and water. Some examples are carbon dioxide capture and sequestration from fossil energy power plants and advanced nuclear fuel cycle scemes. Membrane separations systems are under development to improve the economics of carbon capture that would be required at a huge scale. For nuclear fuel cycles, only the PUREX liquid-liquid extraction process has been deployed on a large scale to recover uranium and plutonium from used fuel. Most current R and D on separations technology for used nuclear fuel focuses on ehhancements to a PUREX-type plant to recover the minor actinides (neptunium, americiu, and curium) and more efficiently disposition the fission products. Are there more efficient routes to recycle the actinides on the horizon? Some new approaches and barriers to development will be briefly reviewed.

  9. Reactor water clean-up device

    International Nuclear Information System (INIS)

    Sawa, Toshio; Takahashi, Sankichi; Takashima, Yoshie.

    1983-01-01

    Purpose: To efficiently eliminate radioactive materials such as iron oxide and cobalt ions with less heat loss by the use of an electrode assembly applied with a direct current. Constitution: In a reactor water clean-up device adapted to pass reactor water through an electrode assembly comprising at least a pair of anode and cathode applied with a direct current to eliminate various types of ions contained in the reactor water by way of the electrolysis or charge neutralization at the anode, the cathode is constituted with a corrosion resistant grid-like or porous metal plate and a layer to the upper portion of the metal plate filled with a plurality of metal spheres of about 1 - 5 mm diameter, and the anode is made of insoluble porous or spirally wound metal material. (Seki, T.)

  10. A cup of coffee with biodiversity and clean drinking water, please

    DEFF Research Database (Denmark)

    Bosselmann, Aske Skovmand

    2012-01-01

    Sales of clean water, CO2 credits and the protection of biodiversity can benefit the environment and provide an extra income for farmers who grow coffee under the shade of trees.......Sales of clean water, CO2 credits and the protection of biodiversity can benefit the environment and provide an extra income for farmers who grow coffee under the shade of trees....

  11. 75 FR 52735 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2010-08-27

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9189-7] Clean Water Act Section 303(d): Availability of List...: This notice announces the availability of EPA's decision identifying 12 water quality limited waterbodies and associated pollutants in South Dakota to be listed pursuant to the Clean Water Act Section 303...

  12. 77 FR 27770 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2012-05-11

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9670-5] Clean Water Act Section 303(d): Availability of List...: This notice announces EPA's decision identifying certain water quality limited waterbodies, and the associated pollutant, in Utah to be listed pursuant to the Clean Water Act Section 303(d)(2), and requests...

  13. 76 FR 20664 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2011-04-13

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9294-5] Clean Water Act Section 303(d): Availability of List... notice announces the availability of EPA's action identifying water quality limited segments and associated pollutants in Louisiana to be listed pursuant to Clean Water Act Section 303(d), and request for...

  14. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  15. Food-Growing, Air- And Water-Cleaning Module

    Science.gov (United States)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  16. The Solubility of Ozone in Deionized Water and its Cleaning Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Han, J.H.; Park, J.G. [Hanyang University, Seoul (Korea, Republic of); Kwak, Y.S. [Hanyang Technology Co., Ltd., Ansan (Korea, Republic of)

    1998-06-01

    The purpose of this study was to investigate the behavior of ozone in DI water and the reaction with wafers during the semiconductor wet cleaning process. The solubility of ozone in DI water was not only dependent on the temperature but also directly proportional to the input concentration of ozone. The lower the initial ozone concentration and the temperature, the longer the half-life time of ozone. The reaction order of ozone in DI water was calculated to be around 1.5. The redox potential reached a saturation value in 5min and slightly increased as the input ozone concentrations increased. The completely hydrophilic surface was created in 1min when HF etched silicon wafer was cleaned in ozonized DI water containing higher ozone concentrations than 2ppm. Spectroscopic ellipsometry measurements showed that the chemical oxide formed by ozonized DI water was measured to be thicker than that by piranha solution. The wafers contaminated with a non-ionic surfactant were more effectively cleaned in ozonized DI water than in piranha and ozonized piranha solutions. (author). 19 refs., 11 figs., 1 tab.

  17. Does Clean Water Make You Dirty? Water Supply and Sanitation in the Philippines

    Science.gov (United States)

    Bennett, Daniel

    2012-01-01

    Water supply investments in developing countries may inadvertently worsen sanitation if clean water and sanitation are substitutes. This paper examines the negative correlation between the provision of piped water and household sanitary behavior in Cebu, the Philippines. In a model of household sanitation, a local externality leads to a sanitation…

  18. Cleaning of OPR1000 Steam Generator by Ultrasonic Cavitation in Water

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Wootae [Korea Hydro and Nuclear Power Co., Ltd, Daejeon (Korea, Republic of); Kim, Sangtae; Yoon, Sangjung; Choi, Yongseok [Saean Engineering Corporation, Seoul (Korea, Republic of)

    2013-05-15

    Magnetic wheels are attached to the transducers to prevent tube damage which may be caused by wear between the transducers and SG tubes. To remove heat generated by transducers, we used water to water heat exchanger. Sludge removed from tube sheet area of the steam generator was pumped to filtering station for removing impurities in it. We designed an ultrasonic cleaning system for application to OPR1000 S/G. The technology was developed for removing sludge in OPR1000 S/G. However, the technology could easily be applied to other types of S/Gs. For cleaning OPR1000 SG, we designed an ultrasonic cleaning system with 12 transducers, 15 generators, a WRS, and a water treatment system. An experiment with a single transducer and the full scale OPR1000 S/G mock-up did not show very satisfactory result in ultrasound energy level. However, we expect sufficient effects if we apply 12 or more transducers in this case considering our previous experimental results as shown in the references. The ultrasonic cleaning system will be ready in August this year for performance test. After several experiments and the experiments followed, we are planning to apply this cleaning system for removing sludge in Korean OPR1000 S/Gs.

  19. Water supply, waste water cleaning and waste disposal. 2. rev. ed.

    International Nuclear Information System (INIS)

    Knoch, W.

    1994-01-01

    The first part of the book contains fundamentals of chemistry, always having environmental protection in mind. Numerous examples are calculated. The second part gives detailed explanations of the material-scientific and analytical bases of the indispensable resource water and its conditioning, waste water cleaning and sludge treatment. Collection, transport, handling, disposal and recycling of unavoidable wastes and toxic wastes are finally dealt with. (orig./EF) [de

  20. Healthcare worker and family caregiver hand hygiene in Bangladeshi healthcare facilities: results from the Bangladesh National Hygiene Baseline Survey.

    Science.gov (United States)

    Horng, L M; Unicomb, L; Alam, M-U; Halder, A K; Shoab, A K; Ghosh, P K; Opel, A; Islam, M K; Luby, S P

    2016-11-01

    Healthcare facility hand hygiene impacts patient care, healthcare worker safety, and infection control, but low-income countries have few data to guide interventions. To conduct a nationally representative survey of hand hygiene infrastructure and behaviour in Bangladeshi healthcare facilities to establish baseline data to aid policy. The 2013 Bangladesh National Hygiene Baseline Survey examined water, sanitation, and hand hygiene across households, schools, restaurants and food vendors, traditional birth attendants, and healthcare facilities. We used probability proportional to size sampling to select 100 rural and urban population clusters, and then surveyed hand hygiene infrastructure in 875 inpatient healthcare facilities, observing behaviour in 100 facilities. More than 96% of facilities had 'improved' water sources, but environmental contamination occurred frequently around water sources. Soap was available at 78-92% of handwashing locations for doctors and nurses, but just 4-30% for patients and family. Only 2% of 4676 hand hygiene opportunities resulted in recommended actions: using alcohol sanitizer or washing both hands with soap, then drying by air or clean cloth. Healthcare workers performed recommended hand hygiene in 9% of 919 opportunities: more after patient contact (26%) than before (11%). Family caregivers frequently washed hands with only water (48% of 2751 opportunities), but with little soap (3%). Healthcare workers had more access to hand hygiene materials and performed better hand hygiene than family, but still had low adherence. Increasing hand hygiene materials and behaviour could improve infection control in Bangladeshi healthcare facilities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. 76 FR 72973 - Notice of Lodging of Consent Decree Under the Clean Water Act and Safe Drinking Water Act

    Science.gov (United States)

    2011-11-28

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act and Safe Drinking Water Act Notice is hereby given that on November 21, 2011, a proposed Consent Decree (``proposed... penalties under the Clean Water Act, 33 U.S.C. 1251-387; the Safe Drinking Water Act, 42 U.S.C. 300f-300j-26...

  2. Optimizing UF Cleaning in UF-SWRO System Using Red Sea Water

    KAUST Repository

    Bahshwan, Mohanad

    2012-07-01

    Increasing demand for fresh water in arid and semi-arid areas, similar to the Middle East, pushed for the use of seawater desalination techniques to augment freshwater. Seawater Reverse Osmosis (SWRO) is one of the techniques that have been commonly used due to its cost effectiveness. Recently, the use of Ultrafiltration (UF) was recommended as an effective pretreatment for SWRO membranes, as opposed to conventional methods (i.e. sand filtration). During UF operation, intermittent cleaning is required to remove particles and contaminants from the membrane\\'s surface and pores. The different cleaning steps consume chemicals and portion of the product water, resulting in a decrease in the overall effectiveness of the process and hence an increase in the production cost. This research focused on increasing the plant\\'s efficiency through optimizing the cleaning protocol without jeopardizing the effectiveness of the cleaning process. For that purpose, the design of experiment (DOE) focused on testing different combinations of these cleaning steps while all other parameters (such as filtration flux or backwash flux) remained constant. The only chemical used was NaOCI during the end of each experiment to restore the trans-membrane pressure (TMP) to its original state. Two trains of Dow™ Ultrafiltration SFP-2880 were run in parallel for this study. The first train (named UF1) was kept at the manufacturer\\'s recommended cleaning steps and frequencies, while the second train (named UF2) was varied according to the DOE. The normalized final TMP was compared to the normalized initial TMP to measure the fouling rate of the membrane at the end of each experiment. The research was supported by laboratory analysis to investigate the cause of the error in the data by analyzing water samples collected at different locations. Visual inspection on the results from the control unit showed that the data cannot be reproduced with the current feed water quality. Statistical analysis

  3. Drinking and Cleaning Water Use in a Dairy Cow Barn

    Directory of Open Access Journals (Sweden)

    Michael Krauß

    2016-07-01

    Full Text Available Water is used in dairy farming for producing feed, watering the animals, and cleaning and disinfecting barns and equipment. The objective of this study was to investigate the drinking and cleaning water use in a dairy cow barn. The water use was measured on a well-managed commercial dairy farm in North-East Germany. Thirty-eight water meters were installed in a barn with 176 cows and two milking systems (an automatic milking system and a herringbone parlour. Their counts were logged hourly over 806 days. On average, the cows in the automatic milking system used 91.1 (SD 14.3 L drinking water per cow per day, while those in the herringbone parlour used 54.4 (SD 5.3 L per cow per day. The cows drink most of the water during the hours of (natural and artificial light in the barn. Previously published regression functions of drinking water intake of the cows were reviewed and a new regression function based on the ambient temperature and the milk yield was developed (drinking water intake (L per cow per day = −27.937 + 0.49 × mean temperature + 3.15 × milk yield (R2 = 0.67. The cleaning water demand had a mean of 28.6 (SD 14.8 L per cow per day in the automatic milking system, and a mean of 33.8 (SD 14.1 L per cow per day in the herringbone parlour. These findings show that the total technical water use in the barn makes only a minor contribution to water use in dairy farming compared with the water use for feed production.

  4. California's 2002 Clean Water Act Section 303(d) - Impaired Waterbodies

    Data.gov (United States)

    California Natural Resource Agency — This dataset contains California's 2002 Clean Water Act Section 303(d) list which is submitted by the California State Water Resources Control Board. The layer has...

  5. Clean subglacial access: prospects for future deep hot-water drilling

    Science.gov (United States)

    Pearce, David; Hodgson, Dominic A.; Smith, Andrew M.; Rose, Mike; Ross, Neil; Mowlem, Matt; Parnell, John

    2016-01-01

    Accessing and sampling subglacial environments deep beneath the Antarctic Ice Sheet presents several challenges to existing drilling technologies. With over half of the ice sheet believed to be resting on a wet bed, drilling down to this environment must conform to international agreements on environmental stewardship and protection, making clean hot-water drilling the most viable option. Such a drill, and its water recovery system, must be capable of accessing significantly greater ice depths than previous hot-water drills, and remain fully operational after connecting with the basal hydrological system. The Subglacial Lake Ellsworth (SLE) project developed a comprehensive plan for deep (greater than 3000 m) subglacial lake research, involving the design and development of a clean deep-ice hot-water drill. However, during fieldwork in December 2012 drilling was halted after a succession of equipment issues culminated in a failure to link with a subsurface cavity and abandonment of the access holes. The lessons learned from this experience are presented here. Combining knowledge gained from these lessons with experience from other hot-water drilling programmes, and recent field testing, we describe the most viable technical options and operational procedures for future clean entry into SLE and other deep subglacial access targets. PMID:26667913

  6. Improving water, sanitation and hygiene in health-care facilities, Liberia.

    Science.gov (United States)

    Abrampah, Nana Mensah; Montgomery, Maggie; Baller, April; Ndivo, Francis; Gasasira, Alex; Cooper, Catherine; Frescas, Ruben; Gordon, Bruce; Syed, Shamsuzzoha Babar

    2017-07-01

    The lack of proper water and sanitation infrastructures and poor hygiene practices in health-care facilities reduces facilities' preparedness and response to disease outbreaks and decreases the communities' trust in the health services provided. To improve water and sanitation infrastructures and hygiene practices, the Liberian health ministry held multistakeholder meetings to develop a national water, sanitation and hygiene and environmental health package. A national train-the-trainer course was held for county environmental health technicians, which included infection prevention and control focal persons; the focal persons acted as change agents. In Liberia, only 45% of 701 surveyed health-care facilities had an improved water source in 2015, and only 27% of these health-care facilities had proper disposal for infectious waste. Local ownership, through engagement of local health workers, was introduced to ensure development and refinement of the package. In-county collaborations between health-care facilities, along with multisectoral collaboration, informed national level direction, which led to increased focus on water and sanitation infrastructures and uptake of hygiene practices to improve the overall quality of service delivery. National level leadership was important to identify a vision and create an enabling environment for changing the perception of water, sanitation and hygiene in health-care provision. The involvement of health workers was central to address basic infrastructure and hygiene practices in health-care facilities and they also worked as stimulators for sustainable change. Further, developing a long-term implementation plan for national level initiatives is important to ensure sustainability.

  7. 75 FR 43554 - Notice of Lodging of Consent Decree Under the Federal Water Pollution Control Act (“Clean Water...

    Science.gov (United States)

    2010-07-26

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Federal Water Pollution Control Act (``Clean Water Act'') Notice is hereby given that on July 21, 2010, a proposed Consent Decree... Sections 301 and 308 of the Clean Water Act, 33 U.S.C. 1311 and 1318, at thirteen of its facilities in...

  8. Clean water and family forest management: some emerging issues

    Science.gov (United States)

    Peter A. Bisson

    2011-01-01

    Demand for clean water for a variety of uses will increase. Watersheds are where we live, grow crops and create various forms of industry. As the Pacific Northwest's human population expands, competition for water and the ecological goods and services that water provides will grow more intense. With this in mind it is helpful to review emerging issues that are of...

  9. A home-based clean water revolution | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2010-12-08

    Dec 8, 2010 ... Highly effective yet simple BioSand Filters are providing clean water in more ... Manz, the University of Calgary civil engineering professor who developed the filter. ... Keeping the technology in the public domain has allowed ...

  10. Hard surface biocontrol in hospitals using microbial-based cleaning products.

    Directory of Open Access Journals (Sweden)

    Alberta Vandini

    Full Text Available Healthcare-Associated Infections (HAIs are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies.This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans on hard surfaces in a hospital setting.The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy and approximately 20000 microbial surface samples were collected.Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3-4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities.This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost

  11. Hard surface biocontrol in hospitals using microbial-based cleaning products.

    Science.gov (United States)

    Vandini, Alberta; Temmerman, Robin; Frabetti, Alessia; Caselli, Elisabetta; Antonioli, Paola; Balboni, Pier Giorgio; Platano, Daniela; Branchini, Alessio; Mazzacane, Sante

    2014-01-01

    Healthcare-Associated Infections (HAIs) are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies. This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans) on hard surfaces in a hospital setting. The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy) and approximately 20000 microbial surface samples were collected. Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3-4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities. This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost-effective strategy

  12. Glufosinate ammonium clean-up procedure from water samples using SPE

    Science.gov (United States)

    Tayeb M., A.; Ismail B., S.; Mardiana-Jansar, K.; Ta, Goh Choo; Agustar, Hani Kartini

    2015-09-01

    For the determination of glufosinate ammonium residue in soil and water samples, different solid phase extraction (SPE) sorbent efficiency was studied. Four different SPE sorbents i.e.: CROMABOND PS-H+, CROMABOND PS-OH-, ISOLUTE ENV+, Water Sep-Pak and OASIS HLB were used. Sample clean-up performance was evaluated using high performance liquid chromatography (Agilent 1220 infinity LC) with fluorescence detector. Detection of FMO-derivatives was done at λ ex = 260 nm and λ em= 310 nm. OASIS HLB column was the most suitable for the clean-up in view of the overall feasibility of the analysis.

  13. 78 FR 27233 - Clean Water Act: Availability of List Decisions

    Science.gov (United States)

    2013-05-09

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9811-4] Clean Water Act: Availability of List Decisions AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the availability of EPA's action identifying water quality limited segments and associated...

  14. Analysis of UV filters in tap water and other clean waters in Spain.

    Science.gov (United States)

    Díaz-Cruz, M Silvia; Gago-Ferrero, Pablo; Llorca, Marta; Barceló, Damià

    2012-03-01

    The present paper describes the development of a method for the simultaneous determination of five hormonally active UV filters namely benzophenone-3 (BP3), 3-(4-methylbenzylidene) camphor (4MBC), 2-ethylhexyl 4-(dimethylamino) benzoate (OD-PABA), 2-ethylhexyl 4-methoxycinnamate (EHMC) and octocrylene (OC) by means of solid-phase extraction and gas chromatography-electron impact ionization-mass spectrometry. Under optimized conditions, this methodology achieved low method limits of detection (needed for clean waters, especially drinking water analysis), between 0.02 and 8.42 ng/L, and quantitative recovery rates higher than 73% in all cases. Inter- and intraday precision for all compounds were lower than 7% and 11%, respectively. The optimized methodology was applied to perform the first survey of UV absorbing compounds in tap water from the metropolitan area and the city of Barcelona (Catalonia, Spain). In addition, other types of clean water matrices (mineral bottled water, well water and tap water treated with an ion-exchange resin) were investigated as well. Results evidenced that all the UV filters investigated were detected in the water samples analyzed. The compounds most frequently found were EHMC and OC. Maximum concentrations reached in tap water were 290 (BP3), 35 (4MBC), 110 (OD-PABA), 260 (EHMC), and 170 ng/L (OC). This study constitutes the first evidence of the presence of UV filter residues in tap water in Europe.

  15. Solar photocatalytic cleaning of polluted water. Solare Reinigung verschmutzter Waesser mittels Photokatalyse

    Energy Technology Data Exchange (ETDEWEB)

    Bockelmann, D

    1994-01-01

    Alternatively to biological, physical and chemical methods of waste water cleaning, photocatalysis can be employed. In this residue-free method, titanium dioxide particles are brought into contact with polluted water as photocatalysts. Under UV irradiation at wave-lengths below 400 nm, change carriers are generated in the semiconductor particles that act so intensely oxidizing as to completely degrade almost all organic pollutants in waste water. In this process, the ultra-violet part of the solar spectrum can be harnessed to generate oxidation equivalents. Thus, solar photocatalytic waste water cleaning is excellently suited for developing countries. (BWI)

  16. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water Pollution...

  17. Chicago Clean Air, Clean Water Project: Environmental Monitoring for a Healthy, Sustainable Urban Future

    Energy Technology Data Exchange (ETDEWEB)

    none, none; Tuchman, Nancy [Institute of Environmental Sustainability (IES), Chicago, IL (United States)

    2015-11-11

    The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has been launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.

  18. Water management for sustainable and clean energy in Turkey

    Directory of Open Access Journals (Sweden)

    Ibrahim Yuksel

    2015-11-01

    Full Text Available Water management has recently become a major concern for many countries. During the last century consumption of water and energy has been increased in the world. This trend is anticipated to continue in the decades to come. One of the greatest reasons is the unplanned industrial activities deteriorating environment in the name of rising standard of life. What is needed is the avoidance of environmental pollution and maintenance of natural balance, in the context of sustainable development. However, Turkey’s geographical location has several advantages for extensive use of most of the renewable energy resources. There is a large variation in annual precipitation, evaporation and surface run-off parameters, in Turkey. Precipitation is not evenly distributed in time and space throughout the country. There are 25 hydrological basins in Turkey. But the rivers often have irregular regimes. In this situation the main aim is to manage and use the water resources for renewable, sustainable and clean energy. This paper deals with water management for renewable, sustainable and clean energy in Turkey.

  19. Federal Disaster Funding Opportunities for Water and Wastewater Utilities through the Drinking Water and Clean Water State Revolving Funds

    Science.gov (United States)

    The following provides a checklist that will help you take advantage of Drinking Water State Revolving Funds. For more detailed information on Drinking Water SRF, see DWSRF in Fed FUNDS. For more information on Clean Water SRF, see CWSRF in Fed FUNDS.

  20. Water Conservation and Reuse. Instructor Guide. Working for Clean Water: An Information Program for Advisory Committees.

    Science.gov (United States)

    Pennsylvania State Univ., Middletown. Inst. of State and Regional Affairs.

    Described is a learning session on water conservation intended for citizen advisory groups interested in water quality planning. Topics addressed in this instructor's manual include water conservation needs, benefits, programs, technology, and problems. These materials are components of the Working for Clean Water Project. (Author/WB)

  1. Clean Water Act 303(d) Listed Impaired Waters and their Causes of Impairment from All Years

    Data.gov (United States)

    U.S. Environmental Protection Agency — Waters identified as impaired as well as their associated causes of impairment from all approved Clean Water Act 303(d) lists submitted by the states. Includes all...

  2. Clean Water Act (excluding Section 404)

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-15

    This Reference Book contains a current copy of the Clean Water Act (excluding Section 404) and those regulations that implement the statutes and appear to be most relevant to US Department of Energy (DOE) activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, EH-231 (202/586-2609).

  3. Evaluating exposure of pedestrians to airborne contaminants associated with non-potable water use for pavement cleaning.

    Science.gov (United States)

    Seidl, M; Da, G; Ausset, P; Haenn, S; Géhin, E; Moulin, L

    2016-04-01

    Climate change and increasing demography press local authorities to look after affordable water resources and replacement of drinking water for city necessities like street and pavement cleaning by more available raw water. Though, the substitution of drinking by non-drinking resources demands the evaluation of sanitary hazards. This article aims therefore to evaluate the contribution of cleaning water to the overall exposure of city dwellers in case of wet pavement cleaning using crossed physical, chemical and biological approaches. The result of tracer experiments with fluorescein show that liquid water content of the cleaning aerosol produced is about 0.24 g m(-3), rending possible a fast estimation of exposure levels. In situ analysis of the aerosol particles indicates a significant increase in particle number concentration and particle diameter, though without change in particle composition. The conventional bacterial analysis using total coliforms as tracer suggests that an important part of the contamination is issued from the pavement. The qPCR results show a more than 20-fold increase of background genome concentration for Escherichia coli and 10-fold increase for Enterococcus but a negligible contribution of the cleaning water. The fluorescence analysis of the cleaning aerosol confirms the above findings identifying pavement surface as the major contributor to aerosol organic load. The physical, chemical and microbiological approaches used make it possible to describe accurately the cleaning bioaerosol and to identify the existence of significantly higher levels of all parameters studied during the wet pavement cleaning. Though, the low level of contamination and the very short time of passage of pedestrian in the zone do not suggest a significant risk for the city dwellers. As the cleaning workers remain much longer in the impacted area, more attention should be paid to their chronic exposure.

  4. 78 FR 44599 - Notice of Lodging of Proposed Consent Decree Under the Clean Water Act

    Science.gov (United States)

    2013-07-24

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Proposed Consent Decree Under the Clean Water Act On... seeking permanent injunctive relief and civil penalties under the Clean Water Act (``CWA''), 33 U.S.C..., manganese, potassium, sodium, strontium, bromide, chloride, [[Page 44600

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ... It's in your hands - prevent sepsis in health care' A 5 May 2018 advocacy message from WHO - ...

  6. Notification: Oversight of Clean Water State Revolving Loan Funds

    Science.gov (United States)

    Project #OA-FY15-0153, April 6, 2015. The Office of Inspector General (OIG) for the U.S. Environmental Protection Agency (EPA) is beginning preliminary research on the EPA oversight of the Clean Water State Revolving Fund (CWSRF).

  7. Sunoco Pipeline, L.P. Clean Water Act Settlement - 2017

    Science.gov (United States)

    EPA, and the U.S. Department of Justice announced that Sunoco Pipeline, L.P. (Sunoco) has agreed to pay a civil penalty for alleged violation of the Clean Water Act stemming from a 2012 gasoline discharge near Wellington, Ohio.

  8. Implementation of State Obligations and Responsibility Ensuring the Availability of Clean Water in Karimunjawa Islands

    Science.gov (United States)

    Rahayu; Soeprobowati, Tri Retnaningsih

    2018-02-01

    This article aims to analyze the implementation of state obligations and responsibility ensuring the availability of clean water as part of human rights in Karimunjawa islands. The analysis based on principle of the State obligations and responsibility to fulfill their citizen right. Water sources in Karimunjawa Islands is very limited. It depend on forest conservation. Around 9.600 peoples live in Karimunjawa Islands, but Karimunjawa is non groundwater basin region. It means, Karimunjawa doesn't have groundwater potential. The quantity of water depends on the season. The solution to maintain the sustainability of clean water is piping from water reservoir to residential areas. The problem is there are so many hotels in Karimunjawa islands, it disrupted the fulfillment of clean water. Besides utilizing water from reservoir, many hotels drilled the ground to get water. It had impact to the availibity of water in dry season and affected to fulfillment of water supply for Karimunjawa people. There is no specific regulation and policy to solve this problem. Clean water management is doing by Karimunjawa's people. Meanwhile, based on Mahkamah Konstitusi Decree number 85/PUU-XI/2013, state is a rights holder to dominate the water in accordance with the Articles 33 paragraph (2) and (3) UUD NRI 1945, so the government has an obligation to make a policy, regulations, management, and supervision.

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... reminding healthcare providers to clean their hands. See: https://www.cdc.gov/handhygiene/campa... . Comments on this ... are allowed in accordance with our comment policy: http://www.cdc.gov/SocialMedia/Tools/... This video can ...

  10. Dealing with the Clean Water Act pending reauthorization

    International Nuclear Information System (INIS)

    Mathews, S.

    1994-01-01

    This report addresses probable changes in the Clean Water Act that may affect federal facilities such as those under the DOE. These changes will be included in a reauthorization of the act. The author draws upon the 1992 National Water Quality Inventory Report to Congress as a source to identify changes in the focus of the reauthorized act on non-point source issues, watershed management, new enforcement mechanisms and an assortment of smaller issues that will have indirect effects on federal facilities

  11. Vertically Aligned Graphene Sheets Membrane for Highly Efficient Solar Thermal Generation of Clean Water.

    Science.gov (United States)

    Zhang, Panpan; Li, Jing; Lv, Lingxiao; Zhao, Yang; Qu, Liangti

    2017-05-23

    Efficient utilization of solar energy for clean water is an attractive, renewable, and environment friendly way to solve the long-standing water crisis. For this task, we prepared the long-range vertically aligned graphene sheets membrane (VA-GSM) as the highly efficient solar thermal converter for generation of clean water. The VA-GSM was prepared by the antifreeze-assisted freezing technique we developed, which possessed the run-through channels facilitating the water transport, high light absorption capacity for excellent photothermal transduction, and the extraordinary stability in rigorous conditions. As a result, VA-GSM has achieved average water evaporation rates of 1.62 and 6.25 kg m -2 h -1 under 1 and 4 sun illumination with a superb solar thermal conversion efficiency of up to 86.5% and 94.2%, respectively, better than that of most carbon materials reported previously, which can efficiently produce the clean water from seawater, common wastewater, and even concentrated acid and/or alkali solutions.

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  13. Cleaning of conveyor belt materials using ultrasound in a thin layer of water.

    Science.gov (United States)

    Axelsson, L; Holck, A; Rud, I; Samah, D; Tierce, P; Favre, M; Kure, C F

    2013-08-01

    Cleaning of conveyor belts in the food industry is imperative for preventing the buildup of microorganisms that can contaminate food. New technologies for decreasing water and energy consumption of cleaning systems are desired. Ultrasound can be used for cleaning a wide range of materials. Most commonly, baths containing fairly large amounts of water are used. One possibility to reduce water consumption is to use ultrasonic cavitation in a thin water film on a flat surface, like a conveyor belt. In order to test this possibility, a model system was set up, consisting of an ultrasound transducer/probe with a 70-mm-diameter flat bottom, operating at 19.8 kHz, and contaminated conveyor belt materials in the form of coupons covered with a thin layer of water or water with detergent. Ultrasound was then applied on the water surface at different power levels (from 46 to 260 W), exposure times (10 and 20 s), and distances (2 to 20 mm). The model was used to test two different belt materials with various contamination types, such as biofilms formed by bacteria in carbohydrate- or protein-fat-based soils, dried microorganisms (bacteria, yeasts, and mold spores), and allergens. Ultrasound treatment increased the reduction of bacteria and yeast by 1 to 2 log CFU under the most favorable conditions compared with water or water-detergent controls. The effect was dependent on the type of belt material, the power applied, the exposure time, and the distance between the probe and the belt coupon. Generally, dried microorganisms were more easily removed than biofilms. The effect on mold spores was variable and appeared to be species and material dependent. Spiked allergens were also efficiently removed by using ultrasound. The results in this study pave the way for new cleaning designs for flat conveyor belts, with possibilities for savings of water, detergent, and energy consumption.

  14. California's 2002 Clean Water Act Section 303(d) - Impaired Streams and Rivers

    Data.gov (United States)

    California Natural Resource Agency — This dataset contains California's 2002 Clean Water Act Section 303(d) list which is submitted by the California State Water Resources Control Board. The layer has...

  15. Cleaning Up Our Drinking Water

    International Nuclear Information System (INIS)

    Manke, Kristin L.

    2007-01-01

    Imagine drinking water that you wring out of the sponge you've just used to wash your car. This is what is happening around the world. Rain and snow pass through soil polluted with pesticides, poisonous metals and radionuclides into the underground lakes and streams that supply our drinking water. 'We need to understand this natural system better to protect our groundwater and, by extension, our drinking water,' said Pacific Northwest National Laboratory's Applied Geology and Geochemistry Group Manager, Wayne Martin. Biologists, statisticians, hydrologists, geochemists, geologists and computer scientists at PNNL work together to clean up contaminated soils and groundwater. The teams begin by looking at the complexities of the whole environment, not just the soil or just the groundwater. PNNL researchers also perform work for private industries under a unique use agreement between the Department of Energy and Battelle, which operates the laboratory for DOE. This research leads to new remediation methods and technologies to tackle problems ranging from arsenic at old fertilizer plants to uranium at former nuclear sites. Our results help regulators, policy makers and the public make critical decisions on complex environmental issues

  16. A preliminary investigation of the barriers to clean water access in the urban slums of Kolkata, India

    Directory of Open Access Journals (Sweden)

    Holly Anne Beistline

    2016-01-01

    Full Text Available Introduction: Safe drinking water is scarce in Kolkata. Inadequate knowledge and poor practices of storing and cleaning drinking water can cause severe effects on the health of the population. There is a need to understand the current trend of attitudes and practices of individuals living in urban slums to reduce water-borne diseases and mortality. This limited convenience sample study attempted to explore and identify areas for further study regarding the barriers of clean water access in urban slums of Kolkata, India. Methods: This pilot cross-sectional study was conducted in Kolkata, India during July 2014. Five urban slums were selected based on proximity and cooperation from the community. A sample of 50 women was taken, representing the five slums, with a sample of 10 women taken from each slum. Results: The majority (80% of the participants said they regularly have enough water available to meet the needs of their household. Fifty-two percent of subjects received their water for drinking from a tap, hand pump, or time pump. Thirty percent had water pumped into their homes, and 18% purchased their water from a water truck. Fourteen percent said they did not treat their water because it was too time consuming, 40% said it was too much work, and 34% said it was not needed. Ninety percent said they felt it was important to clean their water, almost half (48% thought their water was not clean, but only 42% used some method to clean their water. Many subjects (68% stated they knew how to clean their water, but 66% were unaware that visible dirt is not an indicator of illness-causing bacteria in water. Conclusions: More focus should be directed towards improving awareness and knowledge and changing attitudes, motivation, and perceived susceptibility to disease from water within slum communities in Kolkata, India.

  17. Cleaning conveyor belts in the chicken-cutting area of a poultry processing plant with 45°c water.

    Science.gov (United States)

    Soares, V M; Pereira, J G; Zanette, C M; Nero, L A; Pinto, J P A N; Barcellos, V C; Bersot, L S

    2014-03-01

    Conveyor belts are widely used in food handling areas, especially in poultry processing plants. Because they are in direct contact with food and it is a requirement of the Brazilian health authority, conveyor belts are required to be continuously cleaned with hot water under pressure. The use of water in this procedure has been questioned based on the hypothesis that water may further disseminate microorganisms but not effectively reduce the organic material on the surface. Moreover, reducing the use of water in processing may contribute to a reduction in costs and emission of effluents. However, no consistent evidence in support of removing water during conveyor belt cleaning has been reported. Therefore, the objective of the present study was to compare the bacterial counts on conveyor belts that were or were not continuously cleaned with hot water under pressure. Superficial samples from conveyor belts (cleaned or not cleaned) were collected at three different times during operation (T1, after the preoperational cleaning [5 a.m.]; T2, after the first work shift [4 p.m.]; and T3, after the second work shift [1:30 a.m.]) in a poultry meat processing facility, and the samples were subjected to mesophilic and enterobacterial counts. For Enterobacteriaceae, no significant differences were observed between the conveyor belts, independent of the time of sampling or the cleaning process. No significant differences were observed between the counts of mesophilic bacteria at the distinct times of sampling on the conveyor belt that had not been subjected to continuous cleaning with water at 45°C. When comparing similar periods of sampling, no significant differences were observed between the mesophilic counts obtained from the conveyor belts that were or were not subjected to continuous cleaning with water at 45°C. Continuous cleaning with water did not significantly reduce microorganism counts, suggesting the possibility of discarding this procedure in chicken processing.

  18. Algal Turf Scrubbers: Cleaning Water While Capturing Solar Energy

    International Nuclear Information System (INIS)

    Adey, W.

    2009-01-01

    Algal Turfs and Algal Turf Scrubbers (ATS) Algal Turfs are bio diverse communities of unicellular to filamentous algae of all major algal phyla. Algal Turf Scrubbers (ATS) are bioengineered ecosystems dominated by algal turfs. They clean water to very high quality, and remove CO 2 from the atmosphere by capturing solar energy at rates 10 times that of agriculture and 50 times that of forestry. ATS was invented at the Smithsonian Institution, by scientist, Walter Adey in the 1980s as a tool for controlling water quality in highly diverse model ecosystems. The technology received extensive R and D for aqua cultural, municipal, and industrial water cleaning by Dr. Adey, using venture capital, through the 1990s. Later, Hydro Mentia, Inc., of Ocala, Florida, engineered ATS to landscape scale of 20-50 Mgpd (it is important to note that this is a modular system, capable of expanding to any size.) A 2005 independent study of ATS, by the South Florida Water Management District and the IFAS Institute of the University of Florida, certified ATS as 5-100 times more cost efficient at removing nutrients from Everglades canal waters than the next competitor, the STA, a managed marsh system. ATS and STA were the final contestants in a 15-year study of nine technologies, and ATS was the only technology that created a use able byproduct.

  19. A climate risk assessment of clean water supply in an urban area: A case study of South Tangerang city, Indonesia

    Science.gov (United States)

    Nastiti, S. I. W.; Kusnoputranto, H.; Boer, R.; Utomo, S. W.

    2018-03-01

    The demand for clean water in South Tangerang, Indonesia, is very high. At present, this demand is mostly met by groundwater that is much influenced by climate variability, land cover change, and human activities. The local company on water services (PDAM) provides clean water services for only about 9% of the population. The climate risk assessment conducted by South Tangerang Government in 2016 indicates that several areas are potentially exposed to a high risk of climate change. Survey and in-depth interview with communities and sectoral officers suggest that a risk to clean water supply in this city is increasing. This study aims to assess climate potential risks on clean water supply based on the 2016 study. We adopted the method of that study by modifying some of the vulnerability indicators that can represent clean water access and supply. The results of the study demonstrate that many wards in South Tangerang would be exposed to high climate risks of clean water supply. By 2021, about 54% of wards would be exposed from high to the very very high risk of clean water supply. These results signify the tangible need of adaptation actions, to prevent the worsening impacts of climate on clean water supply.

  20. Steam cleaning device

    International Nuclear Information System (INIS)

    Karaki, Mikio; Muraoka, Shoichi.

    1985-01-01

    Purpose: To clean complicated and long objects to be cleaned having a structure like that of nuclear reactor fuel assembly. Constitution: Steams are blown from the bottom of a fuel assembly and soon condensated initially at the bottom of a vertical water tank due to water filled therein. Then, since water in the tank is warmed nearly to the saturation temperature, purified water is supplied from a injection device below to the injection device above the water tank on every device. In this way, since purified water is sprayed successively from below to above and steams are condensated in each of the places, the entire fuel assembly elongated in the vertical direction can be cleaned completely. Water in the reservoir goes upward like the steam flow and is drained together with the eliminated contaminations through an overflow pipe. After the cleaning has been completed, a main steam valve is closed and the drain valve is opened to drain water. (Kawakami, Y.)

  1. Emerging investigator series: the rise of nano-enabled photothermal materials for water evaporation and clean water production by sunlight

    KAUST Repository

    Wang, Peng

    2018-04-05

    Solar driven water evaporation and distillation is an ancient technology, but has been rejuvenated by nano-enabled photothermal materials in the past 4 years. The nano-enabled state-of-the-art photothermal materials are able to harvest a full solar spectrum and convert it to heat with extremely high efficiency. Moreover, photothermal structures with heat loss management have evolved in parallel. These together have led to the steadily and significantly improved energy efficiency of solar evaporation and distillation in the past 4 years. Some unprecedented clean water production rates have been reported in small-scale and fully solar-driven devices. This frontier presents a timely and systematic review of the impressive developments in photothermal nanomaterial discovery, selection, optimization, and photothermal structural designs along with their applications especially in clean water production. The current challenges and future perspectives are provided. This article helps inspire more research efforts from environmental nano communities to push forward practical solar-driven clean water production.

  2. 23 CFR 633.211 - Implementation of the Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-04-01

    ... Water Pollution Control Act. 633.211 Section 633.211 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT...) implementing requirements with respect to the Clean Air Act and the Federal Water Pollution Control Act are... Contracts (Appalachian Contracts) § 633.211 Implementation of the Clean Air Act and the Federal Water...

  3. Water, sanitation and hygiene infrastructure and quality in rural healthcare facilities in Rwanda.

    Science.gov (United States)

    Huttinger, Alexandra; Dreibelbis, Robert; Kayigamba, Felix; Ngabo, Fidel; Mfura, Leodomir; Merryweather, Brittney; Cardon, Amelie; Moe, Christine

    2017-08-03

    WHO and UNICEF have proposed an action plan to achieve universal water, sanitation and hygiene (WASH) coverage in healthcare facilities (HCFs) by 2030. The WASH targets and indicators for HCFs include: an improved water source on the premises accessible to all users, basic sanitation facilities, a hand washing facility with soap and water at all sanitation facilities and patient care areas. To establish viable targets for WASH in HCFs, investigation beyond 'access' is needed to address the state of WASH infrastructure and service provision. Patient and caregiver use of WASH services is largely unaddressed in previous studies despite being critical for infection control. The state of WASH services used by staff, patients and caregivers was assessed in 17 rural HCFs in Rwanda. Site selection was non-random and predicated upon piped water and power supply. Direct observation and semi-structured interviews assessed drinking water treatment, presence and condition of sanitation facilities, provision of soap and water, and WASH-related maintenance and record keeping. Samples were collected from water sources and treated drinking water containers and analyzed for total coliforms, E. coli, and chlorine residual. Drinking water treatment was reported at 15 of 17 sites. Three of 18 drinking water samples collected met the WHO guideline for free chlorine residual of >0.2 mg/l, 6 of 16 drinking water samples analyzed for total coliforms met the WHO guideline of hygienic condition and accessible to patients. Regular maintenance of WASH infrastructure consisted of cleaning; no HCF had on-site capacity for performing repairs. Quarterly evaluations of HCFs for Rwanda's Performance Based Financing system included WASH indicators. All HCFs met national policies for water access, but WHO guidelines for environmental standards including water quality were not fully satisfied. Access to WASH services at the HCFs differed between staff and patients and caregivers.

  4. 77 FR 15368 - Clean Water Act; Availability of List Decisions

    Science.gov (United States)

    2012-03-15

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9646-9] Clean Water Act; Availability of List Decisions AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Availability and Request for Public Comment. SUMMARY: This action announces the availability of the Environmental Protection Agency's (EPA...

  5. 78 FR 45925 - Clean Water Act: Availability of List Decisions

    Science.gov (United States)

    2013-07-30

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9840-5] Clean Water Act: Availability of List Decisions AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the availability of EPA's Responsiveness Summary Concerning EPA's May 9, 2013 Public Notice of...

  6. Co-production as deep engagement: Improving and sustaining access to clean water in Ghana and Nigeria

    NARCIS (Netherlands)

    Mangai, M.S.; Vries, M.S. de

    2018-01-01

    PURPOSE – While there is an urgent need for clean water in Ghana and Nigeria, governments lack the financial means to do much to address this need. This does not mean that improving access to clean water is impossible. On the contrary, this paper argued that engaging citizens through

  7. Implementing Biocriteria: Coral Reef Protection Using the Clean Water Act

    Science.gov (United States)

    Biological assessments (surveying the presence, number, size and condition of fish, coral and other biota) provide important information about the health and integrity of coral reef ecosystems. Biological criteria are one means under the Clean Water Act (CWA) that managers can us...

  8. Letter from A & R Transport about Section 308 of the Clean Water Act Discharge of Perfluorinated Compounds

    Science.gov (United States)

    January 16, 2009 letter from Kenneth E. Pate, VP of Safety and Risk Management of A & R Transport, Inc. to EPA Clean Water Enforcement Branch, about an Information Request about the Section 308 of the Clean Water Act, discharge of pefluorinated compounds.

  9. Key Lake mine water spill: further clean-up not required

    International Nuclear Information System (INIS)

    Potvin, R.

    1984-02-01

    The Atomic Energy Control Board (AECB) has concluded that no additional remedial measures are warranted with regard to the mine water spill which occurred in early January at the Key Lake Mining Corporation facility in northern Saskatchewan, and has advised the company to reconsider its proposal for clean-up of the adjoining Gerald Lake basin. On January 5, an estimated 87 million litres of mine water was accidentally released to the environment when a water storage reservoir at the mine site overflowed. The spilled water flowed into the adjoining Gerald Lake catchment area where it has remained adequately contained

  10. The Ready System of Clean Water for Population in Musuk District to Respon Dry Season

    Directory of Open Access Journals (Sweden)

    Yuli Priyana

    2017-07-01

    Full Text Available This research about ready system of clean water in District of Musuk, Sub-Province of Boyolali. This research aim to study how ready system of clean water, research area especially of dry season. That wish to know how much amount of resident drinking water consumption at area District of Musuk. The method of research in this research is survey method. The data which collected in this research consist of primary data result of interview by 150 responded (head of house hold and perception in field. Secondary data an obtain from governmental institution, books, other resource person and reference related to this topic of research. Intake of sample done with area of random sampling, to know the target of research to description analyses and tabulation. The result of research indicate that ready system of clean water at dry season most relying on rainwater with accommodating the rainwater at pools, besides to overcome water of water supply of rain of society buy water of springs pass tank truck, small to partly use surface water and also of PDAM. Water consumption at mean dry season 48.47 liter/day/capita. But at high area (volcanic slope its slimmer consumption in comparing plain area of Fluvial foot/feet of Volcano.

  11. Development of a dynamic model for cleaning ultra filtration membranes fouled by surface water

    NARCIS (Netherlands)

    Zondervan, Edwin; Betlem, Ben H.L.; Roffel, Brian

    2007-01-01

    In this paper, a dynamic model for cleaning ultra filtration membranes fouled by surface water is proposed. A model that captures the dynamics well is valuable for the optimization of the cleaning process. The proposed model is based on component balances and contains three parameters that can be

  12. Practical Approaches for Assessment of Daily and Post-discharge Room Disinfection in Healthcare Facilities.

    Science.gov (United States)

    Deshpande, Abhishek; Donskey, Curtis J

    2017-09-01

    Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.

  13. An Architecture Of Plc Ls Xbc-Dr30e Based Clean Water Controlling System

    Directory of Open Access Journals (Sweden)

    M.Jusuf Jamanawar Purba

    2017-12-01

    Full Text Available In the industrial field the good controlling system is definitely required to improve the working efficiency of a system. The type of controller PLC Programmable Logic Controller used in Clean Water Controlling System in Electrical Workshop with PLC LS XBC-DR30E. Furthermore such system consistently uses two types of component they are Relay and Timer. The clean water pump control aims to pump the water in well A to storage tank B. The pump will work when water-contained well A is marked by sensor level well A on and the water inside storage tank B is under level 3. When the water inside storage tank B is under level 2 both pumps M1 and M2 will work to fill storage tank B. on the contrary when storage tank B is above level 2 only one pump M1 works until the tank reach level 3. In addition when storage tank B is above level 3 both pumps will stop working. However along with the advancement of recent technology the above system can be controlled by using PLC Programmable Logic Controller. Therefore it is possible to apply the controlling method of PLC as the semester Vs practical module. Based on the trial performed the PLC-based clean water system is well-functioned as the working description compiled before the operation of the tool.

  14. 76 FR 62061 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2011-10-06

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9475-4] Clean Water Act Section 303(d): Availability of List... three waterbodies. These three waterbodies were added by EPA because the applicable numeric water... be obtained at EPA Region 6's Web site at http://www.epa.gov/region6/water/npdes/tmdl/index.htm...

  15. Clean-up system for pool water in pressure suppression chamber and operation method therefor

    Energy Technology Data Exchange (ETDEWEB)

    Hirabayashi, Kentaro; Kinoshita, Shoichiro

    1996-09-17

    Pool water in a pressure suppression chamber of a BWR type reactor is sucked by a pump of an after-heat removing system. The pool water pressurized here is sent to the pressure suppression chamber by way of a heat exchanger and a test line backwarding pipeline to stir the pool water in the pressure suppression chamber. Further, the pool water pressurized by the pump is sent to the pressure suppression chamber by way of a filtration desalting device and an exit pipe to purify the pool water. Upon cleaning of pipelines before the start of a periodical test, the pool water sucked by the pump is sent to the filtration desalting device and recovered to the pressure suppression chamber. This can reduce the amount of impurities carried to the suppression chamber. After the cleaning of the pipelines, pool water is passed through the test line backwarding pipeline, so that the pool water can be stirred at the same time. (I.N.)

  16. Streams in Iowa Listed as Impaired in 2010 Under the Clean Water Act

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Under Section 303(d) of the Clean Water Act, states are required from "time to time" to submit a list of waters for which effluent limits will not be sufficient to...

  17. Lakes in Iowa Listed as Impaired in 2010 Under the Clean Water Act

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Under Section 303(d) of the Clean Water Act, states are required from "time to time" to submit a list of waters for which effluent limits will not be sufficient to...

  18. 76 FR 74057 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2011-11-30

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9498-4] Clean Water Act Section 303(d): Availability of List Decisions AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the availability of EPA's action identifying water quality limited segments and...

  19. 75 FR 68783 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2010-11-09

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9223-5] Clean Water Act Section 303(d): Availability of List Decisions AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This action announces the availability of EPA decisions identifying water quality limited segments and...

  20. Applicability of the Clean Water Act to Indian tribes - may tribes stop or constrain a cleanup?

    International Nuclear Information System (INIS)

    Emge, M.L.

    1993-01-01

    Indian tribes retain their sovereign rights of self-government and self-determination unless it is specifically waived by the tribe or abrogated by the US Congress, through treaty or statute. The Clean Water Act does not specifically abrogate tribal sovereignty. This raises the issue of what would occur if an on-scene coordinator decides that cleanup of tribal lands is necessary to protect the public health and welfare, but the tribe does not want the cleanup activities to proceed? May a tribe impede cleanup efforts? During the cleanup of the barge Nestucca oil spill, this occurred when the Quinault Tribe did not allow the OSC to clean lands that the tribe holds sacred. This issue with the Clean Water Act has not been decided by Congress, nor by the courts. Recently, courts have applied at least three different approaches to determine if a statute of general application, such as the Clean Water Act, applies to Indian tribes. The different tests do not always yield the same result. An on-scene coordinator, when confronted with this scenario, might handle the situation in several different ways, or perhaps move to prevent such an occurrence. The different approaches used by the courts can be taken together to gain a sense of whether the Clean Water Act may preempt tribal sovereignty

  1. Development of chemical cleaning formulation for service water system of FBTR

    International Nuclear Information System (INIS)

    Velmurugan, S.; Narasimhan, S.V.; Das, P.C.; Mathur, P.K.

    1995-01-01

    Service water system of Fast Breeder Test Reactor (FBTR) was found to be corroded and at few locations, the corrosion product oxides were choking the smaller diameter pipelines. An attempt was made to develop a chemical cleaning formulation to chemically remove the oxides using a surface conditioner and chelating agents. Of the several complexants tested, hydroxyethylethylene diamine tetraacetic acid (HEDTA) was found to be better than other complexants from the point of view of oxide dissolution efficiency, solubility etc. A two stage chemical cleaning process involving conditioning of the oxide layer with 0.1% tannic acid followed by exposure of the conditioned oxide layer with a formulation containing 1% HEDTA + 0.5% Sodium Gluconate +0.2% hexamine was recommended to remove the corrosion product oxide present in the service water system. (author). 4 refs., 2 tabs

  2. Toward the development of erosion-free ultrasonic cavitation cleaning with gas-supersaturated water

    Science.gov (United States)

    Yamashita, Tatsuya; Ando, Keita

    2015-11-01

    In ultrasonic cleaning, contaminant particles attached at target surfaces are removed by liquid flow or acoustic waves that are induced by acoustic cavitation bubbles. However, the inertial collapse of such bubbles often involve strong shock emission or water hammer by re-entrant jets, thereby giving rise to material erosion. Here, we aim at developing an erosion-free ultrasonic cleaning technique with the aid of gas-supersaturated water. The key idea is that (gaseous) cavitation is triggered easily even with low-intensity sonication in water where gases are dissolved beyond Henry's saturation limit, allowing us to buffer violent bubble collapse. In this presentation, we report on observations of the removal of micron/submicron-sized particles attached at glass surfaces by the action of gaseous cavitation bubbles under low-intensity sonication.

  3. Advances in telescope mirror cleaning

    Science.gov (United States)

    Blanken, Maarten F.; Chopping, Alan K.; Dee, Kevin M.

    2004-09-01

    Metrology and cleaning techniques for telescope mirrors are generally well established. CO2 cleaning and water washing are mainly used. Water washing has proven to be the best method of removing oil and water stains and restoring the aluminium to nearly fresh values. The risk of water getting to unwanted places such as electronics or other optics prevents this method from being employed more often. Recently the Isaac Newton Group introduced a new cleaning technique for their telescope mirrors, which reduces the risks discussed above. This technique uses water vapour instead of water to wash the mirror. The advantage of this method is that the amount of water needed is drastically reduced. In addition the pressure of the vapour will blow away any large dust particles on the mirror and the temperature shock between the vapour and the mirror will help to de-bond the dust particles. Adding a soapy solution will help to clean oil and watermarks of the mirror. This paper describes the vapour cleaning method, tests that have been done and the overall findings.

  4. A home-based clean water revolution | CRDI - Centre de recherches ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    8 déc. 2010 ... Highly effective yet simple BioSand Filters are providing clean water in more than 300000 homes around the world. Early support from ... Keeping the technology in the public domain has allowed non-governmental organizations to bring the filters to communities across the globe. “Sometimes I'll get an ...

  5. Financing CHP Projects at Wastewater Treatment Facilities with Clean Water State Revolving Funds

    Science.gov (United States)

    This factsheet provides information about CHP at wastewater treatment facilities, including applications, financial challenges, and financial opportunities, such as the Clean Water State Revolving Fund.

  6. Stethoscope Cleaning During Patient Care.

    Science.gov (United States)

    Ghumman, Ghazi Wahla; Ahmad, Nina; Pop-Vicas, Aurora; Iftikhar, Sadia

    2018-05-01

    We conducted a cross-sectional survey of healthcare workers in two community teaching hospitals to better understand clinicians' beliefs and practices related to cleaning of their stethoscopes. The study was conducted from September 2015 to May 2016. Among the total 358 responses received, 45%, 40%, 10% and 5% were from attending physicians, medical students, nurses, and resident physicians, respectively. Although the majority of the respondents (76%) frequently used a stethoscope at work, and almost all (93%) believed that stethoscopes can be involved in pathogen transmission, only 29% of participants reported cleaning their stethoscopes after every use. Hospitals should include stethoscope cleaning into their overall infection prevention efforts. [Full article available at http://rimed.org/rimedicaljournal-2018-05.asp].

  7. C&S Enterprise, L.L.C. - Clean Water Act Public Notice

    Science.gov (United States)

    The EPA is providing notice of a proposed Administrative Penalty Assessment against C & S Enterprise, L.L.C. (“Respondent”), a business located at 2454 480th Ave, Deep River, IA 52222, for alleged violations of the Clean Water Act at property owned by Resp

  8. State of Hawaii, Department of Health, Clean Water Branch State-wide Water Quality Sampling Dataset 1999-2006 (NODC Accession 0013723)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Monitoring Section of the State of Hawaii, Department of Health, Clean Water Branch collects water quality data at over 300 coastal locations state-wide using...

  9. State of Hawaii, Department of Health, Clean Water Branch State-wide Water Quality Sampling Dataset 1973-1998 (NODC Accession 0013724)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Monitoring Section of the State of Hawaii, Department of Health, Clean Water Branch collects water quality data at over 300 coastal locations state-wide using...

  10. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  11. CORAL REEF BIOLOGICAL CRITERIA: USING THE CLEAN WATER ACT TO PROTECT A NATIONAL TREASURE

    Science.gov (United States)

    Coral reefs are declining at unprecedented rates worldwide due to multiple interactive stressors including climate change and land-based sources of pollution. The Clean Water Act (CWA) can be a powerful legal instrument for protecting water resources, including the biological inh...

  12. Clean Water Act (CWA) Action Plan Implementation Priorities: Changes to Improve Water Quality, Increase Compliance and Expand Transparency

    Science.gov (United States)

    The Clean Water Act (CWA) Action Plan Implementation Priorities describes the new approaches to revamp the National Pollutant Discharge Elimination System (NPDES) permitting, compliance and enforcement program.Issued May 11, 2011

  13. Method of cleaning pipeline in control rod drive

    International Nuclear Information System (INIS)

    Baba, Mikiya.

    1993-01-01

    A step of filtering cleaning water by a provisional filter unit and a step of returning filtered cleaning water to a provisional tank are disposed. That is, purified water is stored in the provisional tank and it is sucked by a driving pump under pressure by way of a suction filter into the pipelines in a control rod drive system to clean them. Purified water after the cleaning is filtered by the provisional filter unit and returned to the provisional tank by way of provisional pipelines to form a closed loop. A great amount of purified water to be used is no more necessary by thus changing the water passing cleaning method to the recycling cleaning method, which moderate influences on other steps using purified water and ensure a cleaning step for pipelines in a CRD system, in addition, save the steps for plant construction greatly. (N.H.)

  14. 75 FR 26956 - Clean Water Act Section 303(d): Availability of Los Angeles Area Lakes Total Maximum Daily Loads...

    Science.gov (United States)

    2010-05-13

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9146-6] Clean Water Act Section 303(d): Availability of Los...: Notice of availability. SUMMARY: This action announces the availability of EPA proposed total maximum... nutrient, mercury, chlordane, dieldrin, DDT, PCB, and trash impairments pursuant to Clean Water Act Section...

  15. Efficient methods of piping cleaning

    Directory of Open Access Journals (Sweden)

    Orlov Vladimir Aleksandrovich

    2014-01-01

    Full Text Available The article contains the analysis of the efficient methods of piping cleaning of water supply and sanitation systems. Special attention is paid to the ice cleaning method, in course of which biological foil and various mineral and organic deposits are removed due to the ice crust buildup on the inner surface of water supply and drainage pipes. These impurities are responsible for the deterioration of the organoleptic properties of the transported drinking water or narrowing cross-section of drainage pipes. The co-authors emphasize that the use of ice compared to other methods of pipe cleaning has a number of advantages due to the relative simplicity and cheapness of the process, economical efficiency and lack of environmental risk. The equipment for performing ice cleaning is presented, its technological options, terms of cleansing operations, as well as the volumes of disposed pollution per unit length of the water supply and drainage pipelines. It is noted that ice cleaning requires careful planning in the process of cooking ice and in the process of its supply in the pipe. There are specific requirements to its quality. In particular, when you clean drinking water system the ice applied should be hygienically clean and meet sanitary requirements.In pilot projects, in particular, quantitative and qualitative analysis of sediments adsorbed by ice is conducted, as well as temperature and the duration of the process. The degree of pollution of the pipeline was estimated by the volume of the remote sediment on 1 km of pipeline. Cleaning pipelines using ice can be considered one of the methods of trenchless technologies, being a significant alternative to traditional methods of cleaning the pipes. The method can be applied in urban pipeline systems of drinking water supply for the diameters of 100—600 mm, and also to diversion collectors. In the world today 450 km of pipelines are subject to ice cleaning method.Ice cleaning method is simple

  16. Feasibility, safety, and economic implications of whey-recovered water in cleaning-in-place systems: A case study on water conservation for the dairy industry.

    Science.gov (United States)

    Meneses, Yulie E; Flores, Rolando A

    2016-05-01

    Water scarcity is threatening food security and business growth in the United States. In the dairy sector, most of the water is used in cleaning applications; therefore, any attempt to support water conservation in these processes will have a considerable effect on the water footprint of dairy products. This study demonstrates the viability for recovering good quality water from whey, a highly pollutant cheese-making by-product, to be reused in cleaning-in-place systems. The results obtained in this study indicate that by using a combined ultrafiltration and reverse osmosis system, 47% of water can be recovered. This system generates protein and lactose concentrates, by-products that once spray-dried fulfill commercial standards for protein and lactose powders. The physicochemical and microbiological quality of the recovered permeate was also analyzed, suggesting suitable properties to be reused in the cleaning-in-place system without affecting the quality and safety of the product manufactured on the cleaned equipment. A cost analysis was conducted for 3 cheese manufacturing levels, considering an annual production of 1, 20, and 225 million liters of whey. Results indicate the feasibility of this intervention in the dairy industry, generating revenues of $0.18, $3.05, and $33.4 million per year, respectively. The findings provide scientific evidence to promote the safety of reuse of reconditioned water in food processing plants, contributing to building a culture of water conservation and sustainable production throughout the food supply chain. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. 75 FR 20351 - Clean Water Act Section 303(d): Availability of One Total Maximum Daily Load (TMDL) in Arkansas

    Science.gov (United States)

    2010-04-19

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9139-5] Clean Water Act Section 303(d): Availability of One...: Notice of availability. SUMMARY: This notice announces the availability of the administrative record file... in the State of Arkansas under Section 303(d) of the Clean Water Act (CWA). This TMDL was completed...

  18. 75 FR 55577 - Clean Water Act; Contractor Access to Confidential Business Information

    Science.gov (United States)

    2010-09-13

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9200-8] Clean Water Act; Contractor Access to Confidential... Recovery Act (RCRA). Transfer of the information will allow the contractor and subcontractors to access... contractors and subcontractors over the history of the effluent guidelines program. EPA determined that this...

  19. 77 FR 60962 - Clean Water Act; Contractor Access to Confidential Business Information

    Science.gov (United States)

    2012-10-05

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 2 [FRL-9733-8] Clean Water Act; Contractor Access to... transfer of confidential business information to contractor, subcontractors, and consultants. SUMMARY: The... certain industries. We have determined that the contractors listed below require access [[Page 60963

  20. 75 FR 60452 - Clean Water Act; Contractor Access to Confidential Business Information

    Science.gov (United States)

    2010-09-30

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9208-9] Clean Water Act; Contractor Access to Confidential... electric industry to a new subcontractor of a contractor, Eastern Research Group (ERG). EPA previously... contractors and subcontractors to access information necessary to support EPA in the planning, development...

  1. 75 FR 71431 - Clean Water Act Section 303(d): Availability of List Decisions Correction

    Science.gov (United States)

    2010-11-23

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9230-1] Clean Water Act Section 303(d): Availability of List... Availability. SUMMARY: This action corrects a Federal Register notice that published on November 9, 2010 at 75 FR 68783 announcing the availability of EPA decisions identifying water quality limited segments and...

  2. Testing the Waters: From Moringa Seeds to Fruit Peels, Researchers Are Seeking Out New Ways to Clean Up the World?s Drinking Water.

    Science.gov (United States)

    Yan, Wudan

    2017-01-01

    Water on Earth-in our oceans, rivers, lakes, and wetlands-might seem plentiful, but water that is clean and safe enough to drink actually isn't so abundant. Nearly one in ten people still lacks access to safe water worldwide, according to the World Health Organization. In some of the world's most remote and impoverished communities, people live with no taps, showers, flushing toilets, or nearby springs, making it difficult to keep water supplies safe from bacteria, chemicals, and particulates. Moreover, access to clean drinking water isn't just a problem in the developing world; groundwater in developed countries is typically used far more quickly than it is being replenished. As the world population rises, growing numbers of thirsty people could exacerbate already-scant resources.

  3. Application of Self Cleaning Rapid Sand Filter in Water Treatment

    Directory of Open Access Journals (Sweden)

    Ali Reza Rahmani

    2005-08-01

    Full Text Available Rapid sand filter is one of the most important units in the water treatment plants. It has some difficulties in operation such as backwashing. For the solving of this problem a rapid sand filter has designed and built with the self-cleaning backwashing system. This system consist of 3 main constituents; one galvanized siphon and two galvanized steel tanks. One of them is used for filtration and the other used for the storage of filtrated water in elevation for backwashing the system. Water enter from upside of the filter through the inlet pipe, and collected from the under drainage pipe. Then filter water conduct to the storage tank and exit from outlet pipe. In the beginning, the head loss was low, but because of bed clogging by suspended solids, it increases gradually to the designed head loss (1.2m. Then the system is outed of the service automatically and the backwash is began. The main data for the design of system selected from the hydraulic rules of siphons and rapid sand filter criteria. After essential calculations it was constructed and was started operation. For the hydraulic studies a known volume of storage tank was selected and the time needed for the fill (in filtration stage and empty (in backwash stage of water volume with volumetric method were measured. In hydraulic studies the filter surface rate (SOR was selected about 5-7.5m3/m2/hr (1.39-2.08 lit/sec and the flow of water in siphon, during the backwashing was measured 8.7 lit/sec. It can be seen that the siphon passes 4-6 times the inlet raw water thus a negative pressure will created in the siphon which causes the water above the sand bed to be discharged automatically and rinse water from elevated tank flow under the sand bed and back wash it. So according to this study self cleaning rapid sand filter is very useful for water filtration, especially in small population community. The construction of system is rapid, simple and economic.

  4. Clean water provision in rural areas of less developed countries

    Energy Technology Data Exchange (ETDEWEB)

    Roundy, R W

    1985-01-01

    The decade of the 1980s is declared as a time to solve global domestic water supply problems. By 1990 international goals include the provision of adequate quantities of clean water to every person on earth. Such goals are justified on the basis of human health, economic well being, political development and equity and public safety. Drawing upon observations from Ethiopia, Malaysia and Liberia, cases where attempts to provide domestic water to villagers and rural town dwellers are presented. In all cited cases attempts to provide safe water have failed or are in jeopardy. Conclusions drawn from these cases include acknowledgement that global goals will best be achieved by approaching local problems one-by-one and recognizing the technical, environmental and human constraints upon safe water provision interact differently from one site to another. To properly plan, implement and maintain safe water systems the current technical solutions must be combined with the contributions of social and environmental scientists on a case-by-case basis.

  5. Coal-water fuels - a clean coal solution for Eastern Europe

    International Nuclear Information System (INIS)

    Ljubicic, B.; Willson, W.; Bukurov, Z.; Cvijanovic, P.; Stajner, K.; Popovic, R.

    1993-01-01

    Eastern Europe currently faces great economic and environmental problems. Among these problems is energy provision. Coal reserves are large but cause pollution while oil and gas need to be used for export. Formal 'clean coal technologies' are simply too expensive to be implemented on a large scale in the current economic crisis. The promised western investment and technological help has simply not taken place, western Europe must help eastern Europe with coal technology. The cheapest such technology is coal-water fuel slurry. It can substitute for oil, but research has not been carried out because of low oil prices. Coal-water fuel is one of the best methods of exploiting low rank coal. Many eastern European low rank coals have a low sulfur content, and thus make a good basis for a clean fuel. Italy and Russia are involved in such a venture, the slurry being transported in a pipeline. This technology would enable Russia to exploit Arctic coal reserves, thus freeing oil and gas for export. In Serbia the exploitation of sub-Danube lignite deposits with dredging mining produced a slurry. This led to the use and development of hot water drying, which enabled the removal of many of the salts which cause problems in pulverized fuel combustion. The system is economic, the fuel safer to transport then oil, either by rail or in pipelines. Many eastern European oil facilities could switch. 24 refs

  6. Developing technique for waste water cleaning of a division for equipment decontamination

    International Nuclear Information System (INIS)

    Gromoglasov, A.A.; Solyakov, V.K.; Novikov, V.N.; Pil'shchikov, A.P.; Chekalov, A.G.; Sinyukov, M.A.; Pshenichnykh, V.N.

    1989-01-01

    Results are described of developing technique for radionuclide cleaning solutions after metal product decontamination. The method is based on the adagulation with usage of quicklime. The conclusion is method permits to consider it as the main technique for waste water decontamination. 3 refs.; 2 figs.; 3 tabs

  7. The Economic and Social Benefits and the Barriers of Providing People with Disabilities Accessible Clean Water and Sanitation

    Directory of Open Access Journals (Sweden)

    Gregor Wolbring

    2012-11-01

    Full Text Available Resolution A/HRC/RES/16/2 adopted by the UN Human Rights Council on 8 April 2011 declared access to safe drinking water and sanitation a human right. However many people around the globe including people with disabilities do not have access to safe drinking water, hygiene or sanitation facilities. Inaccessibility of clean water sources, hygiene and sanitation facilities negatively impacts among others health, education, the ability to work, and the ability to partake in social activities. This paper looks at the benefits of, and access barriers to, clean water and sanitation for people with disabilities.

  8. Sodium cleaning device for nuclear reactor equipments

    International Nuclear Information System (INIS)

    Fujisawa, Morio.

    1985-01-01

    Purpose: To enable sodium cleaning over the entire length of large size equipments such as control rod drives and primary coolant recycling pumps for use in FBR type reactors. Constitution: A plurality of warm water supply nozzles each having a valve are connected at varying height on the side of a cleaning tank, to which an exhaust line is connected. These nozzles are connected with an exhaust port at the bottom of the tank to constitute a pipeway for cleaning warm water recycling line including a water feed pump and a feedwater heater. The water level in the tank is changed stepwise by successively selecting the warm water feed nozzles. Further, the warm water in the tank is recyclically fed through the nozzles selected at each step of the water level through the recycle line while warming. On the other hand, the pressure inside the tank is reduced through the exhaust line, whereby the warm water in the tank is boiled at low temperature to clean-up sodium on the equipments to be cleaned over the entire length. (Horiuchi, T.)

  9. Letters initiating Clean Water Act 404(c) review of mining at Pebble deposit

    Science.gov (United States)

    Correspondence between EPA and the Pebble Limited Partnership and the State of Alaska initiating review under section 404(c) of the Clean Water Act of potential adverse environmental effects associated with mining the Pebble deposit in southwest Alaska.

  10. Coolant cleaning facility for nuclear reactor

    International Nuclear Information System (INIS)

    Kuboniwa, Takao; Konno, Yasuhiro; Kumaya, Shin; Osumi, Katsumi.

    1982-01-01

    Purpose: To remove cation of radioactive cobalt 60 produced in a reactor water during the ordinary operation of the reactor and chlorine when sea water is leaked in a condenser as well as to suppress an increase in iron clad containing radioactive cobalt 60 in the reactor water when the reactor is stopped. Constitution: A large flow rate high temperature cleaning system having an electromagnetic filter capable of removing radioactive substance in a reactor water, a low temperature cleaning system having a desalting unit using ion exchanger resin, a turbidity meter for measuring the turbidity of the reactor water and a conductivity meter for measuring the conductivity are provided. Further, flow rate control means are provided in the high and low temperature cleaning systems. The flow rate control means of the high temperature cleaning system is controlled by a measured signal of the turbidity meter, and the flow rete control means of the low temperature cleaning system is controlled by the measured signal of the conductivity meter. (Aizawa, K.)

  11. Depauperate macroinvertebrates in a mine affected stream: Clean water may be the key to recovery

    International Nuclear Information System (INIS)

    Battaglia, M.; Hose, G.C.; Turak, E.; Warden, B.

    2005-01-01

    Acid mine drainage (AMD) is frequently linked with changes in macroinvertebrate assemblages, but the relative contribution of water and sediment to toxicity is equivocal. We have shown that the macroinvertebrate fauna of Neubecks Ck, a mine impacted stream in New South Wales, Australia, was much poorer than in two reference streams. Multivariate RELATE analyses indicated that the patterns in the biological data were more strongly correlated with the concentrations of common metals in the surface water than the pore water of these streams. From this we hypothesised that the water was more toxic to the biota than the sediment and we tested this hypothesis with a sediment transplant experiment. Sediment from Neubecks Ck that was placed in reference streams retained high concentrations of metals throughout the experiment, yet supported a macroinvertebrate assemblage similar to that in the reference streams. Sediment from the reference streams that was placed in Neubecks Ck supported few, if any, animals. This indicates that water in Neubecks Ck is toxic to biota, but that sediment is able to support aquatic biota in clean water. Therefore, remediation should focus on improving water quality rather than sediment quality. - Macroinvertebrates colonise contaminated sediment in clean water

  12. State of Hawaii, Department of Health, Clean Water Branch Hanalei, Kauai Water Quality Sampling Dataset October 2005 - November 2006 (NODC Accession 0020391)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Monitoring Section of the State of Hawaii, Department of Health, Clean Water Branch collected water quality data at 8 sites centered on Hanalei Bay on the north...

  13. Ship for the cleaning of water from oil, fuel oil, and other floating objects

    Energy Technology Data Exchange (ETDEWEB)

    Nentvih, V

    1969-12-31

    The newly designed ship for the cleaning of water surface from floating pollution has its bow section built much lower than its main hull. A slanted platform leads to a channel guiding the water into a centrifuge which separates oil from water. Oil proceeds to a reservoir for reprocessing while water is discharged from the ship. A variable ballast controls the depth of submersion of the platform. The ship is equilibrated by means of a built-in air float.

  14. CORE MUSCLE ACTIVITY DURING THE CLEAN AND JERK LIFT WITH BARBELL VERSUS SANDBAGS AND WATER BAGS.

    Science.gov (United States)

    Calatayud, Joaquin; Colado, Juan C; Martin, Fernando; Casaña, José; Jakobsen, Markus D; Andersen, Lars L

    2015-11-01

    While the traditional clean and jerk maneuver implies simultaneous participation of a large number of muscle groups, the use of this exercise with some variations to enhance core muscle activity remains uninvestigated. The purpose of this study was to compare the muscle activity during clean and jerk lift when performed with a barbell, sandbag and a water bag at same absolute load. Descriptive, repeated-measures study. Twenty-one young fit male university students (age: 25 ± 2.66 years; height: 180.71 ± 5.42 cm; body mass: 80.32 ± 9.8 kg; body fat percentage: 12.41 ± 3.56 %) participated. Surface electromyographic (EMG) signals were recorded from the anterior deltoid (AD), external oblique (OBLIQ), lumbar erector spinae (LUMB), and gluteus medius (GM) and were expressed as a percentage of the maximum voluntary isometric contraction (MVIC). There were no significantly significant differences for AD muscle activity between conditions, whereas muscle activation values for OBLIQ (60%MVIC), GM (29%MVIC) and LUMB (85%MVIC) were significantly higher during the water bag power clean and jerk maneuver when compared with the other conditions. The clean and jerk is an exercise that may be used to enhance core muscle activity. Performing the maneuver with water bags resulted in higher core muscle activity compared with sandbag and standard barbell versions. 3.

  15. 77 FR 20020 - Clean Water Act Section 303(d): Availability of List Decisions

    Science.gov (United States)

    2012-04-03

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9655-2] Clean Water Act Section 303(d): Availability of List Decisions AGENCY: Environmental Protection Agency. ACTION: Notice of availability. SUMMARY: This notice announces the availability of EPA's Responsiveness Summary Concerning EPA's November 30, 2011, Public Notice...

  16. Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals .

    Science.gov (United States)

    Carling, P C; Parry, M F; Von Beheren, S M

    2008-01-01

    The quality of environmental hygiene in hospitals is under increasing scrutiny from both healthcare providers and consumers because the prevalence of serious infections due to multidrug-resistant pathogens has reached alarming levels. On the basis of the results from a small number of hospitals, we undertook a study to evaluate the thoroughness of disinfection and cleaning in the patient's immediate environment and to identify opportunities for improvement in a diverse group of acute care hospitals. Prospective multicenter study to evaluate the thoroughness of terminal room cleaning in hospitals using a novel targeting method to mimic the surface contamination of objects in the patient's immediate environment. Twenty-three acute care hospitals. The overall thoroughness of terminal cleaning, expressed as a percentage of surfaces evaluated, was 49% (range for all 23 hospitals, 35%-81%). Despite the tight clustering of overall cleaning rates in 21 of the hospitals, there was marked variation within object categories, which was particularly notable with respect to the cleaning of toilet handholds, bedpan cleaners, light switches, and door knobs (mean cleaning rates, less than 30%; institutional ranges, 0%-90%). Sinks, toilet seats, and tray tables, in contrast, were consistently relatively well cleaned (mean cleaning rates, over 75%). Patient telephones, nurse call devices, and bedside rails were inconsistently cleaned. We identified significant opportunities in all participating hospitals to improve the cleaning of frequently touched objects in the patient's immediate environment. The information obtained from such assessments can be used to develop focused administrative and educational interventions that incorporate ongoing feedback to the environmental services staff, to improve cleaning and disinfection practices in healthcare institutions.

  17. Performances in Tank Cleaning

    Directory of Open Access Journals (Sweden)

    Fanel-Viorel Panaitescu

    2018-03-01

    Full Text Available There are several operations which must do to maximize the performance of tank cleaning. The new advanced technologies in tank cleaning have raised the standards in marine areas. There are many ways to realise optimal cleaning efficiency for different tanks. The evaluation of tank cleaning options means to start with audit of operations: how many tanks require cleaning, are there obstructions in tanks (e.g. agitators, mixers, what residue needs to be removed, are cleaning agents required or is water sufficient, what methods can used for tank cleaning. After these steps, must be verify the results and ensure that the best cleaning values can be achieved in terms of accuracy and reliability. Technology advancements have made it easier to remove stubborn residues, shorten cleaning cycle times and achieve higher levels of automation. In this paper are presented the performances in tank cleaning in accordance with legislation in force. If tank cleaning technologies are effective, then operating costs are minimal.

  18. A comparative study on laser induced shock cleaning of radioactive contaminants in air and water

    Science.gov (United States)

    Kumar, Aniruddha; Prasad, Manisha; Bhatt, R. B.; Behere, P. G.; Biswas, D. J.

    2018-03-01

    Efficient removal of Uranium-di-oxide (UO2) particulates from stainless steel surface was effected by Nd-YAG laser induced plasma shock waves in air as well as in water environment. The propagation velocity of the generated shock wave was measured by employing the photo-acoustic probe deflection method. Monitoring of the alpha activity of the sample with a ZnS (Ag) scintillation detector before and after the laser exposure allowed the estimation of decontamination efficiency defined as the percentage removal of the initial activity. Experiments were carried out to study the effect of laser pulse energy, number of laser exposures, orientation of the sample, the separation between the substrate surface and the onset point of the shock wave on the de-contamination efficiency. The most optimised cleaning was found to occur when the laser beam impinged normally on the sample that was immersed in water and placed at a distance of ∼0.7 mm from the laser focal spot. Analysis of the cleaned surface by optical microscopes established that laser induced shock cleaning in no way altered the surface property. The shock force generated in both air and water has been estimated theoretically and has been found to exceed the Van der Waal's binding force for spherical contaminant particulate.

  19. NHS connecting for health: healthcare professionals, mobile technology, and infection control.

    Science.gov (United States)

    Brady, Richard R W; Chitnis, Shruti; Stewart, Ross W; Graham, Catriona; Yalamarthi, Satheesh; Morris, Keith

    2012-05-01

    Mobile phones improve the efficiency of clinical communication and are increasingly involved in all areas of healthcare delivery. Despite this, healthcare workers' mobile phones provide a known reservoir of pathogenic bacteria, with the potential to undermine infection control efforts aimed at the reducing bacterial cross-contamination in hospitals. This potential could be amplified further when employers require doctors to carry additional electronic devices for communication, without concurrently providing appropriate guidance on decontamination or use. Eighty-seven on-call doctors' mobile phones were sampled for bacterial growth prior to, and 12 h after, a cleaning intervention involving 70% isopropyl alcohol. Seventy-eight percent of doctors were aware that mobile phones could carry pathogenic bacteria, but only 8% cleaned their phones regularly. The cleaning intervention reduced the number of phones that grew bacteria by 79% (55% [48 of 87] before versus 16% [14 of 87] after cleaning). Eight percent of the phones grew Staphyloccus aureus, and 44.8% of phones grew Gram-positive cocci. All S. aureus isolates were methicillin-sensitive. Bacterial contamination was not associated with gender, specialty, or seniority of the phone user (p>0.05). Simple cleaning interventions can reduce the surface bioburden of hospital-provided doctors' mobile phones and therefore the potential for cross-contamination. This cleaning intervention is inexpensive, easily instituted, and effective. Healthcare workers should carry the minimum number of electronic devices on their person, maintain good hand hygiene, and clean their device appropriately in order to minimize the potential for cross-contamination in the work place.

  20. Village of Pender, Nebraska Wastewater Treatment Facility, Pender, Nebraska - Clean Water Act Public Notice

    Science.gov (United States)

    The EPA is providing notice of proposed Administrative Penalty Assessment against the Village of Pender, Nebraska Wastewater Treatment Facility (“Respondent”) for alleged violations of Sections 301 and/or 404 of the Clean Water Act

  1. Treatment of waste water from flue gas cleaning; Behandlung von Abwasser der Rauchgasreinigung

    Energy Technology Data Exchange (ETDEWEB)

    Ogiermann, Klaus; Meyerhoff, Thomas [Berkefeld - VWS Deutschland GmbH, Celle (Germany); Hagen, Klaus [Berkefeld - VWS Deutschland GmbH, Bayreuth (Germany); Basabe, Juan Luis [HPD Process Engineering S.A., Bilbao (Spain); Vendrup, Michael [Krueger A/S, Soeborg (Denmark)

    2012-11-01

    Strict limits must be adhered to for treating waste water incurred during flue gas desulphurisation (FGD). One and two-stage precipitation processes have proven themselves in FGD waste water treatment. Metals can be removed with the MetClean {sup registered} process. Another option is evaporation. Waste water ZLD systems (Zero Liquid Discharge) recover, via a falling film evaporator with subsequent crystallisation, more than 98 % of the water and produce, aside from the condensate, only solid material that can be disposed of in landfill. A further development, named ZLD CoLD trademark, significantly reduces the investment and operating costs of this solution. (orig.)

  2. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals.

    Science.gov (United States)

    Boyce, John M

    2016-01-01

    Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer's recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating "self-disinfecting" surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer "no-touch" (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These "no-touch" technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to

  3. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals

    Directory of Open Access Journals (Sweden)

    John M. Boyce

    2016-04-01

    Full Text Available Abstract Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer’s recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid and cold atmospheric pressure plasma show potential for use in hospitals. Creating “self-disinfecting” surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer “no-touch” (automated decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm light. These “no-touch” technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections

  4. Supply of clean water to the bearings and mechanical seals of the backup pumps

    International Nuclear Information System (INIS)

    Jolas, C.

    1997-01-01

    The purpose of the backup pumps is to cool the primary circuit and pressurised water reactor containment in the case of a primary cooler loss accident. The water taken in by these pumps in the case of accident is loaded with solid particles. In order to ensure correct operation of the bearings and mechanical seals of these machines, they must be supplied with clean water. In other words, the solid particles must be removed from the water intake. Manufacturers generally use cyclonic separators to achieve this. (author)

  5. 75 FR 8697 - Notice of Availability of Class Deviation; Disputes Resolution Procedures Related to Clean Water...

    Science.gov (United States)

    2010-02-25

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9115-1] Notice of Availability of Class Deviation; Disputes Resolution Procedures Related to Clean Water and Drinking Water State Revolving Fund (CWSRF and DWSRF...: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This document provides notice of...

  6. [Importance of cleaning and disinfection of critical surfaces in dental health services. Impact of an intervention program].

    Science.gov (United States)

    Véliz, Elena; Vergara, Teresa; Pearcy, Mercedes; Dabanch, Jeannette

    Introduction Dental care has become a challenge for healthcare associated infection prevention programs, since the environment, within other factors, plays an important role in the transmission chain. Materials and Methods An intervention program was designed for the Dental Unit of Hospital Militar de Santiago, between years 2014 and 2015. The program contemplated 3 stages: diagnostic, intervention and evaluation stage. Objective To improve the safety of critical surfaces involved in dental healthcare. Results During the diagnostic stage, the cleaning and disinfection process was found to be deficient. The most contaminated critical surface was the instrument holder unit, then the clean area and lamp handle. The surfaces that significantly reduced their contamination, after the intervention, were the clean area and the instrument carrier unit. Conclusion Training in the processes of cleaning and disinfecting surfaces and dental equipment is one of the cost-effective strategies in preventing healthcare-associated infections (HCAI), with simple and easy-to-apply methods.

  7. Quality of Drinking Water Treated at Point of Use in Residential Healthcare Facilities for the Elderly.

    Science.gov (United States)

    Sacchetti, Rossella; De Luca, Giovanna; Guberti, Emilia; Zanetti, Franca

    2015-09-09

    Municipal tap water is increasingly treated at the point of use (POU) to improve the acceptability and palatability of its taste. The aim of this study was to assess the bacteriologic and nutritional characteristics of tap water treated at the point of use in residential healthcare facilities for the elderly. Two types of POU devices were used: microfiltered water dispensers (MWDs) and reverse-osmosis water dispensers (ROWDs). All samples of water entering the devices and leaving them were tested for the bacteriological parameters set by Italian regulations for drinking water and for opportunistic pathogens associated with various infections in healthcare settings; in addition, the degree of mineralization of the water was assessed. The results revealed widespread bacterial contamination in the POU treatment devices, particularly from potentially pathogenic species. As expected, the use of ROWDs led to a decrease in the saline content of the water. In conclusion, the use of POU treatment in healthcare facilities for the elderly can be considered advisable only if the devices are constantly and carefully maintained.

  8. Quality of Drinking Water Treated at Point of Use in Residential Healthcare Facilities for the Elderly

    Directory of Open Access Journals (Sweden)

    Rossella Sacchetti

    2015-09-01

    Full Text Available Municipal tap water is increasingly treated at the point of use (POU to improve the acceptability and palatability of its taste. The aim of this study was to assess the bacteriologic and nutritional characteristics of tap water treated at the point of use in residential healthcare facilities for the elderly. Two types of POU devices were used: microfiltered water dispensers (MWDs and reverse-osmosis water dispensers (ROWDs. All samples of water entering the devices and leaving them were tested for the bacteriological parameters set by Italian regulations for drinking water and for opportunistic pathogens associated with various infections in healthcare settings; in addition, the degree of mineralization of the water was assessed. The results revealed widespread bacterial contamination in the POU treatment devices, particularly from potentially pathogenic species. As expected, the use of ROWDs led to a decrease in the saline content of the water. In conclusion, the use of POU treatment in healthcare facilities for the elderly can be considered advisable only if the devices are constantly and carefully maintained.

  9. New catalysts for photocatalytic cleaning of waste water; Neue Katalysatoren zur photokatalytischen Abwasserreinigung

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, M [Inst. for Solarenergieforschung GmbH, Hannover (Germany); Bahnemann, D [Inst. for Solarenergieforschung GmbH, Hannover (Germany); Hirthe, B [Sachtleben Chemie, Duisburg (Germany); Griebler, W D [Sachtleben Chemie, Duisburg (Germany)

    1994-11-01

    Cleaning of polluted ground and waste water meets with particular problems where the group of halogenated hydrocarbons is concerned, which are not, or not readily, to be biologically degraded by conventional techniques. As an alternative technique to waste water cleaning, a method known as photocatalysis was proposed some years ago, which removes the organic pollutants by oxidation at semiconductor particles exposed to a light source. The article reports on a newly developed photocatalyst with distinctly enhanced pollutant degradation efficiency. (orig./EF) [Deutsch] Besondere Schwierigkeiten bei der Reinigung verschmutzter Grund- und Abwaesser bereitet die Gruppe der halogenierten Kohlenwasserstoffe, die sich nicht oder nur schwer auf herkoemmliche Weise biologisch abbauen lassen. Als alternative Technik zur Abwasserreinigung wurde vor einigen Jahren die sogenannte Photokatalyse vorgeschlagen, bei der die organischen Schadstoffe durch Oxidation an belichteten Halbleiterteilchen entfernt werden. Nachfolgend wird ueber einen neu entwickelten Photokatalysator berichtet, mit dessen Hilfe eine deutliche Steigerung der Effektivitaet des photokatalytischen Schadstoffabbaus gelingt. (orig./EF)

  10. Limonene and tetrahydrofurfuryl alcohol cleaning agent

    Science.gov (United States)

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1996-05-07

    The present invention is a tetrahydrofurfuryl alcohol and limonene or terpineol cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  11. Limonene and tetrahydrofurfurly alcohol cleaning agent

    Science.gov (United States)

    Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.

    1997-10-21

    The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.

  12. In the way of clean and safe drinking water : exploring limitations to improvement of the water supply in Bagamoyo District, Tanzania

    OpenAIRE

    Bemspång, Josefina; Segerström, Rebecka

    2009-01-01

    Bagamoyo District, in the Pwani region in Tanzania, supplies a large part of Tanzania'sbiggest city, Dar es Salaam, with water. At the same time many people in rural villages in thedistrict do not have access to clean and safe water. This thesis aims to explore what limitationsthere are to improvement of the rural water supply in Bagamoyo District. Specific attention ispaid to the organizational structure of the water sector and how roles and responsibilities aredivided, defined and communica...

  13. Cleaning device for recycling pump motor cooling system in nuclear reactor

    International Nuclear Information System (INIS)

    Katayama, Kenjiro; Kondo, Takahisa; Shindo, Kenjiro; Akimoto, Jun.

    1996-01-01

    The cleaning device of the present invention comprises a cleaning water supply pump, a filter for filtering the cleaning water and a cap member for isolating the inside of a motor casing from the inside of a reactor pressure vessel. A motor in the motor casing and a pump in the reactor pressure vessel are removed, the cap member is attached to the upper end of the motor casing to isolate the inside of the motor casing from the inside of the reactor pressure vessel. If the cleaning water supply pump is operated in this state, the cleaning water flows from a returning pipeline for cooling water circulation, connected to the motor casing to supply pipelines through a heat exchange and is discharged. The discharged water passes through a filter and is sent again, as the cleaning water, to the cleaning water supply pump. With such procedures, the recycling pump motor cooling system in the BWR type reactor can be cleaned without disposing a cyclone separator and irrespective of presence or absence of reactor coolants in the reactor pressure vessel. (I.N.)

  14. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. The role of the surface environment in healthcare-associated infections.

    Science.gov (United States)

    Weber, David J; Anderson, Deverick; Rutala, William A

    2013-08-01

    This article reviews the evidence demonstrating the importance of contamination of hospital surfaces in the transmission of healthcare-associated pathogens and interventions scientifically demonstrated to reduce the levels of microbial contamination and decrease healthcare-associated infections. The contaminated surface environment in hospitals plays an important role in the transmission of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus spp. (VRE), Clostridium difficile, Acinetobacter spp., and norovirus. Improved surface cleaning and disinfection can reduce transmission of these pathogens. 'No-touch' methods of room disinfection (i.e., devices which produce ultraviolet light or hydrogen peroxide) and 'self-disinfecting' surfaces (e.g., copper) also show promise to decrease contamination and reduce healthcare-associated infections. Hospital surfaces are frequently contaminated with important healthcare-associated pathogens. Contact with the contaminated environment by healthcare personnel is equally as likely as direct contact with a patient to lead to contamination of the healthcare provider's hands or gloves that may result in patient-to-patient transmission of nosocomial pathogens. Admission to a room previously occupied by a patient with MRSA, VRE, Acinetobacter, or C. difficile increases the risk for the subsequent patient admitted to the room to acquire the pathogen. Improved cleaning and disinfection of room surfaces decreases the risk of healthcare-associated infections.

  16. The Sequential Probability Ratio Test: An efficient alternative to exact binomial testing for Clean Water Act 303(d) evaluation.

    Science.gov (United States)

    Chen, Connie; Gribble, Matthew O; Bartroff, Jay; Bay, Steven M; Goldstein, Larry

    2017-05-01

    The United States's Clean Water Act stipulates in section 303(d) that states must identify impaired water bodies for which total maximum daily loads (TMDLs) of pollution inputs into water bodies are developed. Decision-making procedures about how to list, or delist, water bodies as impaired, or not, per Clean Water Act 303(d) differ across states. In states such as California, whether or not a particular monitoring sample suggests that water quality is impaired can be regarded as a binary outcome variable, and California's current regulatory framework invokes a version of the exact binomial test to consolidate evidence across samples and assess whether the overall water body complies with the Clean Water Act. Here, we contrast the performance of California's exact binomial test with one potential alternative, the Sequential Probability Ratio Test (SPRT). The SPRT uses a sequential testing framework, testing samples as they become available and evaluating evidence as it emerges, rather than measuring all the samples and calculating a test statistic at the end of the data collection process. Through simulations and theoretical derivations, we demonstrate that the SPRT on average requires fewer samples to be measured to have comparable Type I and Type II error rates as the current fixed-sample binomial test. Policymakers might consider efficient alternatives such as SPRT to current procedure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Emulsion type dry cleaning system

    International Nuclear Information System (INIS)

    Kohanawa, Osamu; Matsumoto, Hiroyo.

    1988-01-01

    Protective clothing against radioactive contamination used in the radiation controlled areas of nuclear plants has been washed by the same wet washing as used for underwear washing, but recently dry cleaning is getting used in place of wet washing, which generates a large quantity of laundry drain. However, it was required to use wet washing once every five to ten dry cleanings for washing protective clothing, because conventional dry cleaning is less effective in removing water-soluble soils. Therefore, in order to eliminate wet washing, and to decrease the quantity of laundry drains, the emulsion type dry cleaning system capable of removing both oil-soluble and water-soluble soils at a time has been developed. The results of developmental experiments and actual application are presented in this paper. (author)

  18. Revisions to the Clean Water Act Regulatory Definition of Discharge of Dredged Material; Final Rule

    Science.gov (United States)

    The U.S. Army Corps of Engineers (Corps) and the Environmental Protection Agency (EPA) promulgated a final rule Amending a Clean Water Act (CWA) section 404 regulation that defines the term discharge of dredged material.

  19. Reaction of water vapor with a clean liquid uranium surface

    International Nuclear Information System (INIS)

    Siekhaus, W.

    1985-01-01

    To study the reaction of water vapor with uranium, we have exposed clean liquid uranium surfaces to H 2 O under UHV conditions. We have measured the surface concentration of oxygen as a function of exposure, and determined the maximum attainable surface oxygen concentration X 0 /sup s/ as a function of temperature. We have used these measurements to estimate, close to the melting point, the solubility of oxygen (X 0 /sup b/, -4 ) and its surface segregation coefficient β/sup s/(> 10 3 ). 8 refs., 5 figs., 1 tab

  20. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-01-01

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water

  1. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-02-14

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water or other cleaning liquids in the whole cleaning process, which makes them prominent well suited in for water-deficit environments such as deserts. In one embodiment, the solar panel cleaning apparatus comprises one or more rotatable brushes each having a rotational axis and a drive configured to move each of the one or more rotatable brushes in a direction that is not perpendicular to the rotational axis. The solar panel cleaning apparatus is may be configured such that the angle of the rotational axis of at least one of the one or more rotatable brushes is adjustable relative to the direction of travel.

  2. Colloborative International Resesarch on the Water Energy Nexus: Lessons Learned from the Clean Energy Research Center - Water Energy Technologies (CERC-WET)

    Science.gov (United States)

    Remick, C.

    2017-12-01

    The U.S.-China Clean Energy Research Center - Water and Energy Technologies (CERC-WET) is a global research partnership focused on developing and deploying technologies that to allow the U.S. and China to thrive in a future with constrained energy and water resources in a changing global climate. This presentation outlines and addresses the opportunities and challenges for international research collaboration on the so called "water-energy nexus", with a focus on industrial partnership, market readiness, and intellectual property. The U.S. Department of Energy created the CERC program as a research and development partnership between the United States and China to accelerate the development and deployment of advanced clean energy technologies. The United States and China are not only the world's largest economies; they are also the world's largest energy producers and energy consumers. Together, they account for about 40% of annual global greenhouse gas emissions. The bilateral investment in CERC-WET will total $50 million over five years and will target on the emerging issues and cut-edge research on the topics of (1) water use reduction at thermoelectric plants; (2) treatment and management of non-traditional waters; (3) improvements in sustainable hydropower design and operation; (4) climate impact modeling, methods, and scenarios to support improved understanding of energy and water systems; and (5) data and analysis to inform planning and policy.

  3. Self-cleaning efficiency of artificial superhydrophobic surfaces.

    Science.gov (United States)

    Bhushan, Bharat; Jung, Yong Chae; Koch, Kerstin

    2009-03-03

    The hierarchical structured surface of the lotus (Nelumbo nucifera, Gaertn.) leaf provides a model for the development of biomimetic self-cleaning surfaces. On these water-repellent surfaces, water droplets move easily at a low inclination of the leaf and collect dirt particles adhering to the leaf surface. Flat hydrophilic and hydrophobic, nanostructured, microstructured, and hierarchical structured superhydrophobic surfaces were fabricated, and a systematic study of wettability and adhesion properties was carried out. The influence of contact angle hysteresis on self-cleaning by water droplets was studied at different tilt angles (TA) of the specimen surfaces (3 degrees for Lotus wax, 10 degrees for n-hexatriacontane, as well as 45 degrees for both types of surfaces). At 3 degrees and 10 degrees TA, no surfaces were cleaned by moving water applied onto the surfaces with nearly zero kinetic energy, but most particles were removed from hierarchical structured surfaces, and a certain amount of particles were captured between the asperities of the micro- and hierarchical structured surfaces. After an increase of the TA to 45 degrees (larger than the tilt angles of all structured surfaces), as usually used for industrial self-cleaning tests, all nanostructured surfaces were cleaned by water droplets moving over the surfaces followed by hierarchical and microstructures. Droplets applied onto the surfaces with some pressure removed particles residues and led to self-cleaning by a combination of sliding and rolling droplets. Geometrical scale effects were responsible for superior performance of nanostructured surfaces.

  4. Value of Clean Water Resources: Estimating the Water Quality Improvement in Metro Manila, Philippines

    Directory of Open Access Journals (Sweden)

    Shokhrukh-Mirzo Jalilov

    2017-12-01

    Full Text Available While having many positive impacts, a tremendous economic performance and rapid industrial expansion over the last decades in the Philippines has had negative effects that have resulted in unfavorable hydrological and ecological changes in most urban river systems and has created environmental problems. Usually, these effects would not be part of a systematic assessment of urban water benefits. To address the issue, this study investigates the relationship between poor water quality and resident’s willingness to pay (WTP for improved water quality in Metro Manila. By employing a contingent valuation method (CVM, this paper estimates the benefits of the provision of clean water quality (swimmable and fishable in waterbodies of Metro Manila for its residents. Face-to-face interviews were completed with 240 randomly selected residents. Residents expressed a mean WTP of PHP102.44 (USD2.03 for a swimmable water quality (good quality and a mean WTP of PHP102.39 (USD2.03 for fishable water quality (moderate quality. The aggregation of this mean willingness-to-pay value amounted to annual economic benefits from PHP9443 billion to PHP9447 billion (approx. USD190 million per year for all taxpayers in Metro Manila. As expected, these estimates could inform local decision-makers about the benefits of future policy interventions aimed at improving the quality of waterbodies in Metro Manila.

  5. 76 FR 15998 - Notice of Lodging of Consent Decree Under the Clean Water Act

    Science.gov (United States)

    2011-03-22

    ..., treatment plant, and landfill. To address two mines with discharges into the Ohio River Basin, Defendants... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act Notice is..., Defendants will perform injunctive relief with two components. To address four mines with discharges into the...

  6. Modularized and water-cooled photo-catalyst cleaning devices for aquaponics based on ultraviolet light-emitting diodes

    Science.gov (United States)

    Yang, Henglong; Lung, Louis; Wei, Yu-Chien; Huang, Yi-Bo; Chen, Zi-Yu; Chou, Yu-Yang; Lin, Anne-Chin

    2017-08-01

    The feasibility of applying ultraviolet light-emitting diodes (UV-LED's) as triggering sources of photo-catalyst based on titanium dioxide (TiO2) nano-coating specifically for water-cleaning process in an aquaponics system was designed and proposed. The aquaponics system is a modern farming system to integrate aquaculture and hydroponics into a single system to establish an environmental-friendly and lower-cost method for farming fish and vegetable all together in urban area. Water treatment in an aquaponics system is crucial to avoid mutual contamination. we proposed a modularized watercleaning device composed of all commercially available components and parts to eliminate organic contaminants by using UV-LED's for TiO2 photo-catalyst reaction. This water-cleaning module consisted of two coaxial hollowed cylindrical pipes can be submerged completely in water for water treatment and cooling UV-LED's. The temperature of the UV-LED after proper thermal management can be reduced about 16% to maintain the optimal operation condition. Our preliminary experimental result by using Methylene Blue solution to simulate organic contaminants indicated that TiO2 photo-catalyst triggered by UV-LED's can effectively decompose organic compound and decolor Methylene Blue solution.

  7. Investigation of aluminum surface cleaning using cavitating fluid flow

    Energy Technology Data Exchange (ETDEWEB)

    Ralys, Aurimas; Striška, Vytautas; Mokšin, Vadim [Vilnius Gediminas Technical University, Faculty of Mechanics, Department of Machine Engineering, J. Basanavičiaus str.28, 03224, Vilnius (Lithuania)

    2013-12-16

    This paper investigates efficiency of specially designed atomizer used to spray water and cavitate microbubbles in water flow. Surface cleaning system was used to clean machined (grinded) aluminum surface from abrasive particles. It is established that cleaning efficiency depends on diameter of the diffuser, water pressure and distance between nozzle and metal surface. It is obtained that the best cleaning efficiency (100%) is achieved at pressure 36 bar, when diameter of diffuser is 0.4 mm and distance between nozzle and surface is 1 mm. It is also established that satisfactory cleaning efficiency (80%) is achieved not only when atomizer is placed closer to metal surface, but also at larger (120 mm) distances.

  8. Heat exchanger cleaning

    International Nuclear Information System (INIS)

    Gatewood, J.R.

    1980-01-01

    A survey covers the various types of heat-exchange equipment that is cleaned routinely in fossil-fired generating plants, the hydrocarbon-processing industry, pulp and paper mills, and other industries; the various types, sources, and adverse effects of deposits in heat-exchange equipment; some details of the actual procedures for high-pressure water jetting and chemical cleaning of some specific pieces of equipment, including nuclear steam generators. (DN)

  9. Paraffin dispersant application for cleaning subsea flow lines in the deep water Gulf of Mexico cottonwood development

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, David; White, Jake; Pogoson, Oje [Baker Hughes Inc., Houston, TX (United States); Barros, Dalmo; Ramachandran, Kartik; Bonin, George; Waltrich, Paulo; Shecaira, Farid [PETROBRAS America, Houston, TX (United States); Ziglio, Claudio [Petroleo Brasileiro S.A. (CENPES/PETROBRAS), Rio de Janeiro, RJ (Brazil). Centro de Pesquisa e Desenvolvimento

    2012-07-01

    This paper discusses a paraffin dispersant (in seawater) application to clean paraffin deposition from a severely restricted 17.4-mile dual subsea flow line system in the Gulf of Mexico Cottonwood development. In principle, dispersant treatments are simple processes requiring effective dispersant packages and agitation to break-up and disperse deposition. Dispersants have been used onshore for treating wax deposition for decades. Implementation of a treatment in a long deep water production system, however, poses numerous challenges. The Cottonwood application was one of the first ever deep water dispersant applications. The application was designed in four separate phases: pre-treatment displacement for hydrate protection, dispersant treatment for paraffin deposition removal, pigging sequence for final flow line cleaning, and post-treatment displacement for hydrate protection. In addition, considerable job planning was performed to ensure the application was executed in a safe and environmentally responsible manner. Two dynamically positioned marine vessels were used for pumping fluids and capturing returns. The application was extremely successful in restoring the deep water flow lines back to near pre-production state. Final pigging operations confirmed the flow lines were cleaned of all restrictions. Significant paraffin deposition was removed in the application. Approximately 900 bbls of paraffin sludge was recovered from the 4000 bbl internal volume flow line loop. Furthermore, the application was completed with zero discharge of fluids. The application provided significant value for the Cottonwood development. It allowed production from wells to be brought on-line at a higher capacity, thereby generating increased revenue. It also allowed resumption of routine pigging operations. As such, the Cottonwood dispersant application illustrates that with proper planning and execution, paraffin dispersant treatments can be highly effective solutions for cleaning

  10. Control rod guide tube cleaning device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi; Shiota, Yoshiaki.

    1990-01-01

    Since there was no exclusive device for cleaning control rods, no effective cleaning could not be conducted and there was a possibility that obstacles may not be recovered. Then, there are disposed a first pump for supplying pressurized water, a spray nozzle for forming a swirling flow in a control rod guide tube, a second pump for pressurizing water introduced by a sucking pipeline and a collecting device for recovering obstacles intruding to water from the second pump. The pressurized water supplied from the first pump is introduced to a head passing through a blowing pipe and jetted from the spray nozzle to the control rod guide tube. In this case, a swirling stream occurs and obstacles in the control guide tube are mixed into water. The water containing the obstacles passes from the sucking port through a pipeline, introduced to the second pump and recovered to the collecting device. Since there is no water staying portion upon cleaning operation, the obstacles accumulating over the entire region of the bottom of the guide tube can be recovered reliably and efficiently. (N.H.)

  11. An Evaluation of Common Cleaning Methods for the Removal of a Clinical Isolate of Escherichia coli in Personal Hydration System Water Reservoirs.

    Science.gov (United States)

    Helmus, Stephanie; Blythe, Jauchia; Guevara, Peter; Washington, Michael A

    2016-01-01

    Waterborne infection is an important cause of morbidity and mortality throughout the world. Personal hydration packs have been used by military personnel since the Gulf War and are now a common issue item. Since military personnel tend to operate under austere conditions and may use a variety of water sources, preventing the acquisition of waterborne infections is extremely important. Further, since hydration pack water reservoir replacements may not be available during combat operations, the development of a reliable cleaning protocol for use in the field is essential. Several methods for cleaning have been described. In the current study, three common cleaning methodologies-bleach treatment, baking soda treatment, and proprietary CAMELBAK Cleaning Tabs™-were evaluated for the ability to remove Escherichia coli contamination from hydration pack water reservoirs. The study results suggest that the use of bleach and proprietary CAMELBAK tablets should be encouraged since they both operate by releasing bactericidal chlorine compounds into solution, which is more effective at reducing post-treatment bacterial burden. It should be noted that no method was 100% effective at completely eliminating bacteria from the reservoirs and that mechanical cleaning was not attempted. 2016.

  12. Coolant clean-up system in nuclear reactor

    International Nuclear Information System (INIS)

    Tsuburaya, Hirobumi; Akita, Minoru; Shiraishi, Tadashi; Kinoshita, Shoichiro; Okura, Minoru; Tsuji, Akio.

    1987-01-01

    Purpose: To ensure a sufficient urging pressure at the inlet of a coolant clean-up system pump in a nuclear reactor and eliminate radioactive contaminations to the pump. Constitution: Coolant clean-up system (CUW) pump in a nuclear reactor is disposed to the downstream of a filtration desalter and, for compensating the insufficiency of the urging pressure at the pump inlet, the reactor water intake port to the clean-up system is disposed to the downstream of the after-heat removing pump and the heat exchanger. By compensating the net positive suction head (NPSH) of the clean-up system from the residual heat removing system, the problems of insufficient NPSH for the CUW pump upon reactor shut-down can be dissolved and, accordingly, the reactor clean-up system can be arranged in the order of the heat exchanger, clean-up device and pump. Thus, the CUW pump acts on reactor water after cleaned-up in the clean-up device to reduce the radioactivity contamination to the pump. (Kawakami, Y.)

  13. CORAL REEF BIOLOGICAL CRITERIA: USING THE CLEAN ...

    Science.gov (United States)

    Coral reefs are declining at unprecedented rates worldwide due to multiple interactive stressors including climate change and land-based sources of pollution. The Clean Water Act (CWA) can be a powerful legal instrument for protecting water resources, including the biological inhabitants of coral reefs. The objective of the CWA is to restore and maintain the chemical, physical and biological integrity of water resources. Coral reef protection and restoration under the Clean Water Act begins with water quality standards - provisions of state or Federal law that consist of a designated use(s) for the waters of the United States and water quality criteria sufficient to protect the uses. Aquatic life use is the designated use that is measured by biological criteria (biocriteria). Biocriteria are expectations set by a jurisdiction for the quality and quantity of living aquatic resources in a defined waterbody. Biocriteria are an important addition to existing management tools for coral reef ecosystems. The Technical Support Document “Coral Reef Biological Criteria: Using the Clean Water Act to Protect a National Treasure” will provide a framework to aid States and Territories in their development, adoption, and implementation of coral reef biocriteria in their respective water quality standards. The Technical Support Document “Coral Reef Biological Criteria: Using the Clean Water Act to Protect a National Treasure” will provide a framework for coral re

  14. Comparison of trace metals in intake and discharge waters of power plants using clean techniques

    International Nuclear Information System (INIS)

    Salvito, D.T.; Allen, H.E.

    1995-01-01

    In order to determine the impact to receiving waters of trace metals potentially discharged from a once-through, non-contact cooling water system from a power plant, a study was conducted utilizing clean sampling and analytical techniques for a series of metals. Once-through, non-contact cooling water at power plants is frequently discharged back to the fresh or saline waterbody utilized for its intake water. This water is used to cool plant condensers. Intake and discharge data were collected and evaluated using paired t-tests. Study results indicate that there is no measurable contribution of metals from non-contact cooling water from this power plant

  15. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P [Gas Turbine Efficiency, Jarfalla (Sweden)

    1999-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  16. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P. [Gas Turbine Efficiency, Jarfalla (Sweden)

    1998-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  17. Cleaning and dewatering fine coal

    Science.gov (United States)

    Yoon, Roe-Hoan; Eraydin, Mert K.; Freeland, Chad

    2017-10-17

    Fine coal is cleaned of its mineral matter impurities and dewatered by mixing the aqueous slurry containing both with a hydrophobic liquid, subjecting the mixture to a phase separation. The resulting hydrophobic liquid phase contains coal particles free of surface moisture and droplets of water stabilized by coal particles, while the aqueous phase contains the mineral matter. By separating the entrained water droplets from the coal particles mechanically, a clean coal product of substantially reduced mineral matter and moisture contents is obtained. The spent hydrophobic liquid is separated from the clean coal product and recycled. The process can also be used to separate one type of hydrophilic particles from another by selectively hydrophobizing one.

  18. Keeping condensers clean

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, K.

    2006-04-15

    The humble condenser is among the biggest contributors to a steam power plant's efficiency. But although a clean condenser can provide great economic benefit, a dirty one can raise plant heat rate, resulting in large losses of generation revenue and/or unnecessarily high fuel bills. Conventional methods for cleaning fouled tubes range form chemicals to scrapers to brushes and hydro-blasters. This article compares the available options and describes how one power station, Omaha Public Power District's 600 MW North Omaha coal-fired power station, cleaned up its act. The makeup and cooling water of all its five units comes from the Missouri River. 6 figs.

  19. Governance by green taxes: Implementing clean water policies in Europe 1970 - 1990

    DEFF Research Database (Denmark)

    Andersen, Mikael Skou

    1999-01-01

    This article analyzes the use of economic instruments for environmental policy in four European countries. The study employs data from national and international sources for an ex post evaluation of the effects of economic policy instruments in the clean water programs of Denmark, France, Germany...... to the significance of taking into account the institutional setting of the design and operation of market-based instruments, an observation with both theoretical and practical implications....

  20. Gas plant cleaning case history

    Energy Technology Data Exchange (ETDEWEB)

    Woods, B

    1971-03-22

    Basic steps to be taken before using any cleaning method are select a responsible group and give it full responsibility; know the problem, what type of fouling, lab samples, amount of material, time and cost; sell the idea to management; maintain the cleaning equipment; and follow up each cleaning operation. These principles have been applied to advantage in the amine contractor at Taylor, a vessel 60 ft high with 78-in. OD, containing carbon steel deck trays with stainless steel caps. The original attempt to clean with wire scrapers manually involved much lost time and several crews. There was limited space in the tray vessels, design created areas difficult to clean, working conditions were unpleasant, equipment downtime was extended, labor cost was high, and the final result was not satisfactory. Chemical cleaning was substituted, preceded by a water wash. Five hours of caustic wash with a 3% solution at 170$F were followed by a water wash, an acid wash, 1-hr neutralization with a weak soda ash solution, and finally passivation to eliminate iron oxide. For the acid wash, sulfamic acid was found best, in 10% concentration for 4 hr. Cascading was most economical, but flooding has been employed sometimes at 2-1/2 times the cost, to reach all the dark corners.

  1. The clean water act -- (Federal Water Pollution Control Act), what it means to utilities

    Energy Technology Data Exchange (ETDEWEB)

    Talt, L.A. [Howard and Howard Attorneys, Bloomfield Hills, MI (United States)

    1996-10-01

    Departing from previous policy, in August 1993 the USEPA`s Water Office recommended that the agency regulate a proposed electric power plant`s cooling pond as a water of the US. At issue was a proposal by Florida Power corp. to build a new electric power plant in Polk County, Florida. A 2,600 acre cooling pond to collect heated and discharged water was included in the proposal. Region 4 USEPA staff asked USEPA Headquarters in Washington, DC to decide whether the pond was exempt from the CWA or a water of the US. The pond could be a habitat for migratory birds according to a memo prepared by Region 4 staff. The USEPA Water Office used the presence of migratory birds to claim a nexus to interstate commerce and therefore concluded that the pond should be regulated under the CWA. Electric power industry proponents have argued that an overly expansive definition of waters of the US may result in any new power plant being required to construct cooling towers. Cooling towers are said to be a more expensive and wasteful method to cool heated water. Region 4 ultimately recanted its earlier position after considerable discussions with various other Environmental Protection Agency offices and, no doubt industry pressure. Florida Power Corp. was not required to obtain an NPDES permit for the cooling pond. The lesson of Florida Power Corp. is that the regulatory environment for utilities can be uncertain under the Clean Water Act even in the face of a relatively straightforward exemption from regulation.

  2. Use of wetlands for water quality improvement under the USEPA Region V Clean Lakes Program

    Science.gov (United States)

    Landers, Judith C.; Knuth, Barbara A.

    1991-03-01

    The United States Environmental Protection Agency (USEPA) Region V Clean Lakes Program employs artificial and modified natural wetlands in an effort to improve the water quality of selected lakes. We examined use of wetlands at seven lake sites and evaluated the physical and institutional means by which wetland projects are implemented and managed, relative to USEPA program goals and expert recommendations on the use of wetlands for water quality improvement. Management practices recommended by wetlands experts addressed water level and retention, sheet flow, nutrient removal, chemical treatment, ecological and effectiveness monitoring, and resource enhancement. Institutional characteristics recommended included local monitoring, regulation, and enforcement and shared responsibilities among jurisdictions. Institutional and ecological objectives of the National Clean Lakes Program were met to some degree at every site. Social objectives were achieved to a lesser extent. Wetland protection mechanisms and appropriate institutional decentralization were present at all sites. Optimal management techniques were employed to varying degrees at each site, but most projects lack adequate monitoring to determine adverse ecological impacts and effectiveness of pollutant removal and do not extensively address needs for recreation and wildlife habitat. There is evidence that the wetland projects are contributing to improved lake water quality; however, more emphasis needs to be placed on wetland protection and long-term project evaluation.

  3. High Rate Production of Clean Water Based on the Combined Photo-Electro-Thermal Effect of Graphene Architecture.

    Science.gov (United States)

    Cui, Linfan; Zhang, Panpan; Xiao, Yukun; Liang, Yuan; Liang, Hanxue; Cheng, Zhihua; Qu, Liangti

    2018-04-23

    The use of abundant solar energy for regeneration and desalination of water is a promising strategy to address the challenge of a global shortage of clean water. Progress has been made to develop photothermal materials to improve the solar steam generation performance. However, the mass production rate of water is still low. Herein, by a rational combination of photo-electro-thermal effect on an all-graphene hybrid architecture, solar energy can not only be absorbed fully and transferred into heat, but also converted into electric power to further heat up the graphene skeleton frame for a much enhanced generation of water vapor. As a result, the unique graphene evaporator reaches a record high water production rate of 2.01-2.61 kg m -2 h -1 under solar illumination of 1 kW m -2 even without system optimization. Several square meters of the graphene evaporators will provide a daily water supply that is enough for tens of people. The combination of photo-electro-thermal effect on graphene materials offers a new strategy to build a fast and scalable solar steam generation system, which makes an important step towards a solution for the scarcity of clean water. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Hybrid Pressure Retarded Osmosis−Membrane Distillation (PRO−MD) Process for Osmotic Power and Clean Water Generation

    KAUST Repository

    Han, Gang

    2015-05-20

    A novel pressure retarded osmosis−membrane distillation (PRO−MD) hybrid process has been experimentally conceived for sustainable production of renewable osmotic power and clean water from various waters. The proposed PRO−MD system may possess unique advantages of high water recovery rate, huge osmotic power generation, well controlled membrane fouling, and minimal environmental impacts. Experimental results show that the PRO−MD hybrid process is promising that not only can harvest osmotic energy from freshwater but also from wastewater. When employing a 2 M NaCl MD concentrate as the draw solution, ultrahigh power densities of 31.0 W/m2 and 9.3 W/m2 have been demonstrated by the PRO subsystem using deionized water and real wastewater brine as the feeds, respectively. Simultaneously, high purity potable water with a flux of 32.5−63.1 L/(m2.h) can be produced by the MD subsystem at 40−60 °C without any detrimental effects of fouling. The energy consumption in the MD subsystem might be further reduced by applying a heat exchanger in the hybrid system and using low-grade heat or solar energy to heat up the feed solution. The newly developed PRO−MD hybrid process would provide insightful guidelines for the exploration of alternative green technologies for renewable osmotic energy and clean water production.

  5. 75 FR 8698 - Clean Water Act Section 303(d): Availability of Ten Total Maximum Daily Loads (TMDLs) in Louisiana

    Science.gov (United States)

    2010-02-25

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9118-5] Clean Water Act Section 303(d): Availability of Ten...: Notice of availability. SUMMARY: This notice announces the availability for comment on the administrative... Smith, Environmental Protection Specialist, Water Quality Protection Division, U.S. Environmental...

  6. 76 FR 76161 - Clean Water Act Section 303(d): Availability of Three Total Maximum Daily Loads (TMDLs) in Louisiana

    Science.gov (United States)

    2011-12-06

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9500-1] Clean Water Act Section 303(d): Availability of Three...: Notice of availability. SUMMARY: This notice announces the availability for comment on the administrative... Smith, Environmental Protection Specialist, Water Quality Protection Division, U.S. Environmental...

  7. 76 FR 70442 - Clean Water Act Section 303(d): Availability of 28 Total Maximum Daily Loads (TMDLs) in Louisiana

    Science.gov (United States)

    2011-11-14

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9491-1] Clean Water Act Section 303(d): Availability of 28...: Notice of availability. SUMMARY: This notice announces the availability for comment on the administrative..., Environmental Protection Specialist, Water Quality Protection Division, U.S. Environmental Protection Agency...

  8. 76 FR 80366 - Clean Water Act Section 303(d): Availability of One Total Maximum Daily Load (TMDL) in Louisiana

    Science.gov (United States)

    2011-12-23

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9610-6] Clean Water Act Section 303(d): Availability of One...: Notice of availability. SUMMARY: This notice announces the availability for comment on the administrative..., Environmental Protection Specialist, Water Quality Protection Division, U.S. Environmental Protection Agency...

  9. Potential Implications of Approaches to Climate Change on the Clean Water Rule Definition of "Waters of the United States".

    Science.gov (United States)

    Faust, Derek R; Moore, Matthew T; Emison, Gerald Andrews; Rush, Scott A

    2016-05-01

    The 1972 Clean Water Act was passed to protect chemical, physical, and biological integrity of United States' waters. The U.S. Environmental Protection Agency and U.S. Army Corps of Engineers codified a new "waters of the United States" rule on June 29, 2015, because several Supreme Court case decisions caused confusion with the existing rule. Climate change could affect this rule through connectivity between groundwater and surface waters; floodplain waters and the 100-year floodplain; changes in jurisdictional status; and sea level rise on coastal ecosystems. Four approaches are discussed for handling these implications: (1) "Wait and see"; (2) changes to the rule; (3) use guidance documents; (4) Congress statutorily defining "waters of the United States." The approach chosen should be legally defensible and achieved in a timely fashion to provide protection to "waters of the United States" in proactive consideration of scientifically documented effects of climate change on aquatic ecosystems.

  10. L-Reactor 186-basin cleaning alternatives

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1983-01-01

    Operation of L Reactor will necessitate annual cleaning of the L Area 186 basins. Alternatives are presented for sediment discharge due to 186-basin cleaning activities as a basis for choosing the optimal cleaning method. Current cleaning activities (i.e. removal of accumulated sediments) for the P, C and K-Area 186 basins result in suspended solids concentrations in the effluent waters above the NPDES limits, requiring an exemption from the NPDES permit for these short-term releases. The objective of mitigating the 186-basin cleaning activities is to decrease the suspended solids concentrations to within permit limits while continuing satisfactory operation of the basins

  11. Rudimentary Cleaning Compared to Level 300A

    Science.gov (United States)

    Arpin, Christina Y. Pina; Stoltzfus, Joel

    2012-01-01

    A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.

  12. On-farm comparisons of different cleaning protocols in broiler houses.

    Science.gov (United States)

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  13. Cleaning the Produced Water in Offshore Oil Production by Using Plant-wide Optimal Control Strategy

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Pedersen, Simon; Løhndorf, Petar Durdevic

    2014-01-01

    To clean the produced water is always a challenging critical issue in the offshore oil & gas industry. By employing the plant-wide control technology, this paper discussed the opportunity to optimize the most popular hydrocyclone-based Produced Water Treatment (PWT) system. The optimizations of t...... of this research is to promote a technical breakthrough in the PWT control design, which can lead to the best environmental protection in the oil & gas production, without sacrificing the production capability and production costs....

  14. Forward Osmosis/Low Pressure Reverse Osmosis for Water Reuse: Removal of Organic Micropollutants, Fouling and Cleaning

    KAUST Repository

    Linares, Rodrigo

    2011-07-01

    Forward osmosis (FO) is a natural process in which a solution with high concentration of solutes is diluted when being in contact, through a semipermeable membrane, with a low concentration solution. This osmotic process has been demonstrated to be efficient to recover wastewater effluents while diluting a saline draw solution. Nevertheless, the study of the removal of micropollutants by FO is barely described in the literature. This research focuses on the removal of these substances spiked in a secondary wastewater effluent, while diluting water from the Red Sea, generating feed water that can be desalinated with a low pressure reverse osmosis (LPRO) system. Another goal of this work is to characterize the fouling of the FO membrane, and its effect on micropollutants rejection, as well as the membrane cleaning efficiency of different methods. When considering only FO with a clean membrane, the rejection of the hydrophilic neutral compounds was between 48.6% and 84.7%, for the hydrophobic neutrals the rejection ranged from 40.0% to 87.5%, and for the ionic compounds the rejections were between 92.9% and 96.5%. With a fouled membrane, the rejections were between 44.6% to 95.2%, 48.7% to 91.5% and 96.9% to 98.6%, respectively. These results suggest that, except for the hydrophilic neutral compounds, the rejection of the micropollutants is increased by the fouling layer, possibly due to the higher hydrophilicity of the FO fouled membrane compared to the clean one, the increased adsorption capacity and reduced mass transport capacity, membrane swelling, and the higher negative charge of the surface, related to the foulants. However, when coupled with low pressure reverse osmosis, the rejections for both, the clean and fouled membrane, increased above 98%. The fouling layer, after characterizing the wastewater effluent and the concentrated wastewater after the FO process, proved to be composed of biopolymers, which can be removed with air scouring during short periods

  15. Improving the cleaning procedure to make kitchen floors less slippery.

    Science.gov (United States)

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  16. 76 FR 77226 - Clean Water Act Section 303(d): Availability of 28 Total Maximum Daily Loads (TMDLs) in Louisiana

    Science.gov (United States)

    2011-12-12

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9505-4] Clean Water Act Section 303(d): Availability of 28... public comment period for the notice of availability that published on November 14, 2011, 76 FR 70442... Protection Specialist, Water Quality Protection Division, U.S. Environmental Protection Agency Region 6, 1445...

  17. Measuring process performance within healthcare logistics - a decision tool for selecting track and trace technologies

    DEFF Research Database (Denmark)

    Feibert, Diana Cordes; Jacobsen, Peter

    2015-01-01

    quality of work. Data validity is essential for enabling performance measurement, and selecting the right technologies is important to achieve this. A case study of the hospital cleaning process was conducted at a public Danish hospital to develop a framework for assessing technologies in healthcare......Monitoring tasks and ascertaining quality of work is difficult in a logistical healthcare process due to cleaning personnel being dispersed throughout the hospital. Performance measurement can support the organization in improving the efficiency and effectiveness of processes and in ensuring...... logistics. A set of decision indicators was identified in the case study to assess technologies based on expected process performance. Two aspects of performance measurement were investigated for the hospital cleaning process: what to measure and how to measure it....

  18. ''In sutu'' radiation cleaning of underground water contaminated with cyanides - six years of experience

    International Nuclear Information System (INIS)

    Pastuszek, F.; Vacek, K.; Vondruska, V.

    1993-01-01

    Underground water, contaminated with cyanides, has been successfully cleaned using the hydraulic barrier method (assembly of pumped wells) since 1986. The average cyanide concentrations in the outflow exceeded 35 mg per litre. Contamination had to be eliminated before the discharge into the sewer system. The radiation approach ''in situ'' i.e. decomposition of cyanides by barrier, was applied and is still being used today. The cyanide concentration was lowered more than one order of magnitude. This process was approved by the Czechoslovak radiation security authorities and further applications of ''in situ'' regeneration of underground water contamination is anticipated. (author)

  19. Oil-in-water nanocontainers as low environmental impact cleaning tools for works of art: two case studies.

    Science.gov (United States)

    Carretti, Emiliano; Giorgi, Rodorico; Berti, Debora; Baglioni, Piero

    2007-05-22

    A novel class of p-xylene-in-water microemulsions mainly based on nonionic surfactants and their application as low impact cleaning tool in cultural heritage conservation is presented. Alkyl polyglycosides (APG) and Triton X-100 surfactants allow obtaining very effective low impact oil-in-water (o/w) microemulsions as alternatives to pure organic solvents for the removal of polymers (particularly Paraloid B72 and Primal AC33) applied during previous conservation treatments. The ternary APG/p-xylene/water microemulsions have been characterized by quasi elastic light scattering to obtain the hydrodynamic radius and the polydispersity of the microemulsion droplets. Laplace inversion of the correlation function CONTIN analysis provided evidence of acrylic copolymers solubilization into the oil nanodroplets. Contact angle, Fourier transform infrared (FTIR), and scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS) data confirmed that microemulsions were effective in removing polymer coatings. The phase diagram of APG microemulsions showed that a reduction >90% (compared to the conventional cleaning methods) of the organic solvent can be achieved by using o/w microemulsions. The microemulsions were successfully tested in two real cases: (1) the APG based microemulsion was used in a Renaissance painting by Vecchietta in Santa Maria della Scala, Siena, Italy, degraded by the presence of a polyacrylate coating applied during a previous restoration and (2) a Triton X-100 oil-in-water microemulsion containing (NH4)2CO3 in the water continuous phase. The association of ammoniun carbonate to the microemusion led to the swelling of an organic deposit (mainly asphaltenes deposited on the fresco in the Oratorio di San Nicola al Ceppo in Florence, still contamined by the water of the Arno river during the 1966 flood) and a very efficient removal of highly insoluble inorganic deposits (mainly gypsum) strongly associated to asphaltenes. These innovative systems are

  20. Brushless Cleaning of Solar Panels and Windows

    Science.gov (United States)

    Schneider, H. W.

    1982-01-01

    Machine proposed for cleaning solar panels and reflectors uses multiple vortexes of air, solvent, and water to remove dust and dirt. Uses no brushes that might abrade solar surfaces and thereby reduce efficiency. Machine can be readily automated and can be used on curved surfaces such as aparbolic reflectors as well as on flat ones. Cleaning fluids are recycled, so that large quantities of water and solvent are not needed.

  1. State of Hawaii, Department of Health, Clean Water Branch Special Surveys for Bellow Beach, Oahu, Hawaii 1992-1999 (NODC Accession 0014264)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Monitoring Section of the State of Hawaii, Department of Health, Clean Water Branch collected water quality samples at six sites near the mouth of streams and...

  2. Specialised cleaning associated with antimicrobial coatings for reduction of hospital acquired infection. Opinion of the COST Action Network AMiCI (CA15114).

    Science.gov (United States)

    Dunne, Suzanne S; Ahonen, Merja; Modic, Martina; Crijns, Francy Rl; Keinänen-Toivola, Minna M; Meinke, Ruth; Keevil, C William; Gray, Jim; O'Connell, Nuala H; Dunne, Colum P

    2018-03-14

    Recognized issues with poor hand hygiene compliance among healthcare workers, and reports of re-contamination of previously chemically disinfected surfaces through hand contact, emphasize need for novel hygiene methods in addition to those currently available. One such approach involves antimicrobial (nano)-coatings (AMC), whereby integrated active ingredients are responsible for elimination of microorganisms that come into contact with treated surfaces. While widely studied under laboratory conditions with promising results, studies under real life healthcare conditions are scarce. The views of 75 contributors from 30 European countries were collated regarding specialised cleaning associated with antimicrobial coatings for reduction of hospital acquired infection. There was unanimous agreement that generation of scientific guidelines for cleaning of antimicrobial coatings, using traditional or new processes, are needed. Specific topics included: understanding mechanisms of action of cleaning materials and their physical interactions with conventional and antimicrobial coatings; that assessments mimic the life-cycle of coatings to determine the impact of repetitive cleaning and other aspects of ageing (e.g., exposure to sunlight); determining concentrations of AMC-derived biocides in effluents, and development of effective de-activation and sterilisation treatments for cleaning effluents. Further, the consensus opinion was that prior to widespread implementation of AMCs, the varying responsibilities of involved clinical, healthcare management, cleaning services, and environmental safety stakeholders need clarification. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Consensus statement: patient safety, healthcare-associated infections and hospital environmental surfaces.

    Science.gov (United States)

    Roques, Christine; Al Mousa, Haifaa; Duse, Adriano; Gallagher, Rose; Koburger, Torsten; Lingaas, Egil; Petrosillo, Nicola; Škrlin, Jasenka

    2015-01-01

    Healthcare-associated infections have serious implications for both patients and hospitals. Environmental surface contamination is the key to transmission of nosocomial pathogens. Routine manual cleaning and disinfection eliminates visible soil and reduces environmental bioburden and risk of transmission, but may not address some surface contamination. Automated area decontamination technologies achieve more consistent and pervasive disinfection than manual methods, but it is challenging to demonstrate their efficacy within a randomized trial of the multiple interventions required to reduce healthcare-associated infection rates. Until data from multicenter observational studies are available, automated area decontamination technologies should be an adjunct to manual cleaning and disinfection within a total, multi-layered system and risk-based approach designed to control environmental pathogens and promote patient safety.

  4. Patient and environmental service employee satisfaction of using germicidal bleach wipes for patient room cleaning.

    Science.gov (United States)

    Aronhalt, Kimberly C; McManus, James; Orenstein, Robert; Faller, Rebecca; Link, Mary

    2013-01-01

    More healthcare institutions are using bleach products which are sporicidal to reduce Clostridium difficile infection (CDI). There may be patient and employee concerns about the appearance of bleach residue left on surfaces, odors, and respiratory tract irritation. The intervention used bleach wipes for daily and terminal patient room cleaning to reduce transmission of CDI and was implemented on patient care units with a relatively high incidence of CDI. Both patients and Environmental Services (ES) staff were surveyed to assess their satisfaction of the bleach wipe product used during room cleaning. Patients (n = 94) (91%) continued to be very satisfied with how well their rooms were cleaned every day. Bleach wipes were well tolerated by patients (n = 44) (100%) surveyed on the medical units and less tolerated by patients (n = 50) (22%) on the hematology-oncology units. ES staff (6) reported less satisfaction and more respiratory irritation from using the bleach wipes; however, later their satisfaction improved. © 2012 National Association for Healthcare Quality.

  5. Cleaning must be well planned; Rengjoeringsopplegget maa planlegges

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Both detergents and water may damage painted and varnished surfaces in the long run. It is therefore important to choose the right cleaning method once the rooms are put to use. It is essential that a cleaning method be found that does not require great quantities of chemicals. Professional cleaning implies that a program is used that describes in detail the cleaning operation in each room. Materials used in walls often do not tolerate much moisture. If such components are cleaned by means of too much water to which is added detergents, they may swell. These walls are exposed above all the first time they are cleaned because those doing the cleaning are not aware of the situation. Some of the detergents in current use contain hazardous components. It is very important to know the individual detergent's contents of volatile components as these may cause damage. Some detergents may lead to deterioration of the surface if incorrectly used. Some contain perfume or dyes that may develop allergies. Thus, detergents must be selected with due consideration of both the subject and the personnel. Declaration and user instruction is necessary.

  6. Invertebrate-Based Water Quality Impairments and Associated Stressors Identified through the US Clean Water Act

    Science.gov (United States)

    Govenor, Heather; Krometis, Leigh Anne H.; Hession, W. Cully

    2017-10-01

    Macroinvertebrate community assessment is used in most US states to evaluate stream health under the Clean Water Act. While water quality assessment and impairment determinations are reported to the US Environmental Protection Agency, there is no national summary of biological assessment findings. The objective of this work was to determine the national extent of invertebrate-based impairments and to identify pollutants primarily responsible for those impairments. Evaluation of state data in the US Environmental Protection Agency's Assessment and Total Maximum Daily Load Tracking and Implementation System database revealed considerable differences in reporting approaches and terminologies including differences in if and how states report specific biological assessment findings. Only 15% of waters impaired for aquatic life could be identified as having impairments determined by biological assessments (e.g., invertebrates, fish, periphyton); approximately one-third of these were associated with macroinvertebrate bioassessment. Nearly 650 invertebrate-impaired waters were identified nationwide, and sediment was the most common pollutant in bedded (63%) and suspended (9%) forms. This finding is not unexpected, given previous work on the negative impacts of sediment on aquatic life, and highlights the need to more specifically identify the mechanisms driving sediment impairments in order to design effective remediation plans. It also reinforces the importance of efforts to derive sediment-specific biological indices and numerical sediment quality guidelines. Standardization of state reporting approaches and terminology would significantly increase the potential application of water quality assessment data, reveal national trends, and encourage sharing of best practices to facilitate the attainment of water quality goals.

  7. Clean Water Act (excluding Section 404). Environmental guidance program reference book: Revision 6

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-15

    This Reference Book contains a current copy of the Clean Water Act (excluding Section 404) and those regulations that implement the statutes and appear to be most relevant to US Department of Energy (DOE) activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, EH-231 (202/586-2609).

  8. Cleaning device for steam units in a nuclear power plant

    International Nuclear Information System (INIS)

    Sasamuro, Takemi.

    1978-01-01

    Purpose: To prevent radioactive contamination upon dismantling and inspection of steam units such as a turbine to a building containing such units and the peripheral area. Constitution: A steam generator indirectly heated by steam supplied from steam generating source in a separate system containing no radioactivity is provided to produce cleaning steam. A cleaning steam pipe is connected by way of a stop valve between separation valve of a nuclear power plant steam pipe and a high pressure turbine. Upon cleaning, the separation valve is closed, and steam supplied from the cleaning steam pipe is flown into a condenser. The water thus condensated is returned by way of a feed water heater and a condenser to a water storage tank. (Nakamura, S.)

  9. Overview of shoreline cleaning agents

    International Nuclear Information System (INIS)

    Clayton, J.

    1992-01-01

    Chemical cleaning agents may be used to promote release of stranded oil from shorelines for reasons including biological sensitivity of indigenous fauna and flora to the oil, amenity considerations of the shoreline, or concern about refloating of the oil and subsequent stranding on adjacent shorelines. While use of chemical cleaning agents may be appropriate under proper toxic responses in circumstances, certain limitations should be recognized. The potential for toxic responses in indigenous fauna and flora to the cleaning agents must be considered. Enhanced penetration of oil into permeable shorelines following treatment with chemical cleaning agents also is not desirable. However, if conditions related to toxicity and substrate permeability are determined to be acceptable, the use of chemical cleaning agents for treatment of stranded oil can be considered. Chemical agents for cleaning oiled shorelines can be grouped into three categories: (1) non-surfactant-based solvents, (2) chemical dispersants, and (3) formulations especially designed to release stranded oil from shoreline substrates (i.e., shoreline-cleaning-agents). Depending on the specific circumstances present on an oiled shoreline, it is generally desirable that chemical agents used for cleaning will release oil from shoreline substrate(s) to surface waters. Recovery of the oil can then be accomplished by mechanical procedures such as booming and skimming operations

  10. Hand hygiene in rural Indonesian healthcare workers: barriers beyond sinks, hand rubs and in-service training.

    Science.gov (United States)

    Marjadi, B; McLaws, M-L

    2010-11-01

    Few attempts to increase healthcare workers' hand hygiene compliance have included an in-depth analysis of the social and behavioural context in which hand hygiene is not undertaken. We used a mixed method approach to explore hand hygiene barriers in rural Indonesian healthcare facilities to develop a resource-appropriate adoption of international guidelines. Two hospitals and eight clinics (private and public) in a rural Indonesian district were studied for three months each. Hand hygiene compliance was covertly observed for two shifts each in three adult wards at two hospitals. Qualitative data were collected from direct observation, focus group discussions and semistructured in-depth and informal interviews within healthcare facilities and the community. Major barriers to compliance included longstanding water scarcity, tolerance of dirtiness by the community and the healthcare organisational culture. Hand hygiene compliance was poor (20%; 57/281; 95% CI: 16-25%) and was more likely to be undertaken after patient contact (34% after-patient contact vs 5% before-patient contact, Pperceived to be dirty (49% 'inherent' vs 11% 'elective' opportunities associated with clean contacts, Pcommitment to the provision of supportive working conditions. Copyright © 2010 The Hospital Infection Society. All rights reserved.

  11. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

    International Nuclear Information System (INIS)

    Simon, N.; Lorcet, H.; Beauchamp, F.; Guigues, E.; Lovera, P.; Fleche, J. L.; Lacroix, M.; Carra, O.; Dechelette, F.; Prele, G.; Rodriguez, G.

    2012-01-01

    Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO 2 interaction are also presented. Then, in a second part, a functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)

  13. Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

    Energy Technology Data Exchange (ETDEWEB)

    Simon, N.; Lorcet, H.; Beauchamp, F.; Guigues, E. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Lovera, P.; Fleche, J. L. [CEA, DEN, DPC Saclay, F-91191 Gif-sur-Yvette (France); Lacroix, M. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Carra, O. [AREVA / NP, 10 Rue Juliette Recamier, 69003 Lyon (France); Dechelette, F. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France); Prele, G. [EDF/SEPTEN, 12-14 avenue Dutrievoz, 69628 Villeurbane Cedex (France); Rodriguez, G. [CEA, DEN, DTN Cadarache, F-13108 Saint-Paul-lez-Durance (France)

    2012-07-01

    Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO{sub 2} interaction are also presented. Then, in a second part, a functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)

  14. Characterization of Cleaning and Disinfecting Tasks and Product Use Among Hospital Occupations

    Science.gov (United States)

    Saito, Rena; Virji, M. Abbas; Henneberger, Paul K.; Humann, Michael J.; LeBouf, Ryan F.; Stanton, Marcia L.; Liang, Xiaoming; Stefaniak, Aleksandr B.

    2016-01-01

    Background Healthcare workers have an elevated prevalence of asthma and related symptoms associated with the use of cleaning/disinfecting products. The objective of this study was to identify and characterize cleaning/disinfecting tasks and products used among hospital occupations. Methods Workers from 14 occupations at five hospitals were monitored for 216 shifts, and work tasks and products used were recorded at five-minute intervals. The major chemical constituents of each product were identified from safety data sheets. Results Cleaning and disinfecting tasks were performed with a high frequency at least once per shift in many occupations. Medical equipment preparers, housekeepers, floor strippers/waxers, and endoscopy technicians spent on average 108–177 min/shift performing cleaning/disinfecting tasks. Many occupations used products containing amines and quaternary ammonium compounds for > 100 min/shift. Conclusions This analysis demonstrates that many occupations besides housekeeping incur exposures to cleaning/disinfecting products, albeit for different durations and using products containing different chemicals. PMID:25351791

  15. Biological approaches for addressing the grand challenge of providing access to clean drinking water

    Science.gov (United States)

    2011-01-01

    The U.S. National Academy of Engineering (NAE) recently published a document presenting "Grand Challenges for Engineering". This list was proposed by leading engineers and scientists from around the world at the request of the U.S. National Science Foundation (NSF). Fourteen topics were selected for these grand challenges, and at least seven can be addressed using the tools and methods of biological engineering. Here we describe how biological engineers can address the challenge of providing access to clean drinking water. This issue must be addressed in part by removing or inactivating microbial and chemical contaminants in order to properly deliver water safe for human consumption. Despite many advances in technologies this challenge is expanding due to increased pressure on fresh water supplies and to new opportunities for growth of potentially pathogenic organisms. PMID:21453515

  16. Chemical dynamics of acidity and heavy metals in a mine water-polluted soil during decontamination using clean water.

    Science.gov (United States)

    Chen, A; Lin, C; Lu, W; Ma, Y; Bai, Y; Chen, H; Li, J

    2010-03-15

    A column leaching experiment was conducted to investigate the chemical dynamics of the percolating water and washed soil during decontamination of an acidic mine water-polluted soil. The results show that leaching of the contaminated soil with clean water rapidly reduced soluble acidity and ion concentrations in the soils. However, only soil column was eliminated after 30 leaching cycles. It is likely that the stored acidity continues to be released to the percolating water over a long period of time. During the column leaching, dissolved Cu and Pb were rapidly leached out, followed by mobilization of colloidal Cu and Pb from the exchangeable and the oxide-bound fractions as a result of reduced ionic strength in the soil solution. The soluble Fe contained in the soil was rare, probably because the soil pH was not sufficiently low; marked mobility of colloidal Fe took place after the ionic strength of the percolating water was weakened and the mobilized Fe was mainly derived from iron oxides. In contrast with Cu, Pb and Fe, the concentration of leachate Zn and Mn showed a continuously decreasing trend during the entire period of the experiment. (c) 2009 Elsevier B.V. All rights reserved.

  17. Decontamination of polypropylene fabrics by dry cleaning

    International Nuclear Information System (INIS)

    Severa, J.; Knajfl, J.

    1983-01-01

    Polypropylene fabrics can efficiently be decontaminated by dry cleaning in benzine or perchloroethylene, this also in case the fabric was greased in addition to radioactive contamination. For heavily soiled fabric, it is advantageous to first dry clean it and then wash it. The positive effect was confirmed of intensifiers on the cleaning process, especially of benzine soap. In practice, its concentration should be selected within 1 and 10 g.dm - 3 . Decontamination by dry cleaning and subsequent washing is advantageous in that that the resulting activity of waste water from the laundry is low. Radioactive wastes from the dry cleaning process have a low weight and can be handled as solid waste. (M.D.)

  18. Clean and safe supply of fish and shellfish to clear the HACCP regulation by use of clean and cold deep ocean water in Rausu, Hokkaido, Japan

    Science.gov (United States)

    Mac Takahashi, Masayuki; Yamashita, Kazunori

    2005-07-01

    For the supply of fish and shellfish to consumers in fresh condition, clean handling after catch from the sea is essential. According to HACCP (Hazard Analysis and Critical Control Points), it is important to meet such requirement by keeping fish and shellfish under a certain low temperature and clean conditions after catching. The deep ocean water (DOW) characterized by low temperature and cleanliness has been chosen for fish and shellfish handlings, particularly for salmon, cod, and sea urchin in Town ‘Rausu’ in Hokkaido, Japan. DOW below 2.9’C of an amount of nearly 5 000m3 is planned to be pumped up every day from a depth of about 350 m, and temporarily stored in a large simulated tank on land. DOW is then supplied to fish boats through hydrants distributed throughout the harbor and used for keeping salmon in clean and cold conditions. Ice made from DOW is also used for lowering temperature if necessary. DOW and ice made from DOW are also used during the transportation of fish and shellfish. The entire system is scheduled to be completed by the summer of 2005.

  19. Healthcare and healthcare systems: inspiring progress and future prospects.

    Science.gov (United States)

    Durrani, Hammad

    2016-01-01

    growth will occur in the urban areas of poor countries. The rapid, unplanned and unsustainable style of urban development will make developing countries cities the key focal points for emerging environmental and health hazards. Changes will be seen in design, culture and practices of hospitals to better meet the needs of patients, families and providers. Top driving factors of global healthcare system for next 30 years will be leading causes of mortalities, non-health factors (impact of nutrition, sanitation and women's empowerment), investment in health workforce and growth of medical tourism in future healthcare scenario. Evaluating the patterns of previous 30 years and predicting the progress and challenges of future health system are no rocket science. Medical care will be more self-directed in a more tech-savvy population as information will be more accessible and user friendly with higher quality. Health driving factors such as clean water, sanitation and food will take the center stage in humanities struggle and even increase population size.

  20. 6 Home Cleaning Recipes

    Science.gov (United States)

    ... aluminum, brass, ceramics, chrome, copper, fiberglass, glass/quartz, plastic, and steel. GLASS CLEANER 1 cup vinegar 1 ... originally filled with commercial cleaning products. Instead, reuse plastic water bottles.  Always place a label on the ...

  1. Clean delivery practices in rural northern Ghana: a qualitative study of community and provider knowledge, attitudes, and beliefs

    Directory of Open Access Journals (Sweden)

    Moyer Cheryl A

    2012-06-01

    Full Text Available Abstract Background Knowledge, attitudes and practices of community members and healthcare providers in rural northern Ghana regarding clean delivery are not well understood. This study explores hand washing/use of gloves during delivery, delivering on a clean surface, sterile cord cutting, appropriate cord tying, proper cord care following delivery, and infant bathing and cleanliness. Methods In-depth interviews and focus group discussions were audiotaped, transcribed, and analyzed using NVivo 9.0. Results 253 respondents participated, including women with newborn infants, grandmothers, household and compound heads, community leaders, traditional birth attendants, and formally trained health care providers. There is widespread understanding of the need for clean delivery to reduce the risk of infection to both mothers and their babies during and shortly after delivery. Despite this understanding, the use of gloves during delivery and hand washing during and after delivery were mentioned infrequently. The need for a clean delivery surface was raised repeatedly, including explicit discussion of avoiding delivering in the dirt. Many activities to do with cord care involved non-sterile materials and practices: 1 Cord cutting was done with a variety of tools, and the most commonly used were razor blades or scissors; 2 Cord tying utilized a variety of materials, including string, rope, thread, twigs, and clamps; and 3 Cord care often involved applying traditional salves to the cord - including shea butter, ground shea nuts, local herbs, local oil, or “red earth sand.” Keeping babies and their surroundings clean was mentioned repeatedly as an important way to keep babies from falling ill. Conclusions This study suggests a widespread understanding in rural northern Ghana of the need for clean delivery. Nonetheless, many recommended clean delivery practices are ignored. Overarching themes emerging from this study included the increasing use of

  2. Low-cost engineering techniques in sustainable operation of a rural clean water plant in thailand

    International Nuclear Information System (INIS)

    Pengchai, P.; Keawkhun, K.; Suwapaet, N.

    2012-01-01

    Problems of water supply in many rural regions of Thailand result from the lack of awareness and financial limitations. Payanghang Clean Water Plant is an example of the rural water plant that has been suffering from the poor operation since 2003. The objective of this study was to modify the operation processes of this water plant to achieve cleaner water and better financial condition. Low-cost engineering techniques, such as the use of floating switches in filtration ponds, the use of water drip system for alum dosing and the addition of Tamarindus indica Linn seed solution was applied. As a result, 76% of turbidity removal efficiency was derived. Although, the difference was not statistically significant at 95% confidence level, higher removal efficiency in comparison with the one before modification (65%) suggested better operation. In the view of financial aspect, l07 dollars (1 baht = 0.0326 U.S. dollar) benefit was obtained from 7 month-operation period. (author)

  3. The effect of consumer expectations and perceptions regarding sanitation on access to clean water

    CSIR Research Space (South Africa)

    Duncker, Louiza

    2017-08-01

    Full Text Available and Sanitation Centre. Drangert, Jan-Olof, Louiza Christina Duncker, Gertrude Matsebe, and Victoria Abu Atukunda. 2006. “Ecological Sanitation, Urban Agriculture and Gender in Peri- Journal of Ethical Urban Living 34 urban Settlements: A Comparative Study... the author worked on. Publication Details Journal of Ethical Urban Living (ISSN: 2470-2641). August, 2017. Volume 1, Issue 1. Citation Duncker, Louiza. 2017. “The Effect of Consumer Expectations and Perceptions Regarding Sanitation on Access to Clean Water...

  4. Use of fluorescent tagging for assessment of environmental cleaning and disinfection in a veterinary hospital.

    Science.gov (United States)

    Weese, J S; Lowe, T; Walker, M

    2012-09-01

    Environmental cleaning was assessed at a small animal veterinary referral hospital and associated primary healthcare facility. A convenience sample of surfaces was contaminated with fluorescent dye, and then cleaning was assessed 24 hours later by UV light visualisation. Five hundred sixty-three sites were assessed; however, 70 sites were unable to be evaluated 24 hours later because equipment had been removed or because rooms were occupied at the time of re-evaluation. Overall, dye was removed from 212/493 (43%) of sites. Site-specific rates ranged from 14% (computer keyboards and mice, 9/66 site cleaned) to 81% (examination tables, 44/54 sites cleaned). There was a significant difference in the prevalence of successful cleaning by general location (P cleaning practices. Results prompted further infection control investigations to explain selected deficiencies, leading to identification of inadequacies in protocols and practices. Environmental tagging may be a useful infection control tool for establishing baseline cleaning rates, identifying deficiencies in protocols, evaluating the effects of interventions and education of personnel.

  5. EBR-II facility for cleaning and maintenance of LMR components

    International Nuclear Information System (INIS)

    Washburn, R.A.

    1986-01-01

    The cleaning and maintenance of EBR-II sodium wetted components is accomplished in a separate hands-on maintenance facility known as the Sodium Components Maintenance Shop (SCMS). Sodium removal is mostly done using alcohol but steam or water is used. The SCMS has three alcohol cleaning systems: one for small nonradioactive components, one for small radioactive components, and one for large radioactive components. The SCMS also has a water-wash station for the removal of sodium with steam or water. An Alcohol Recovery Facility removes radioactive contaminants from the alcohol and reclaims the alcohol for reuse. Associated with the large components cleaning system is a major component handling system

  6. Engineering innovation in healthcare: technology, ethics and persons.

    Science.gov (United States)

    Bowen, W Richard

    2011-01-01

    Engineering makes profound contributions to our health. Many of these contributions benefit whole populations, such as clean water and sewage treatment, buildings, dependable sources of energy, efficient harvesting and storage of food, and pharmaceutical manufacture. Thus, ethical assessment of these and other engineering activities has often emphasized benefits to communities. This is in contrast to medical ethics, which has tended to emphasize the individual patient affected by a doctor's actions. However technological innovation is leading to an entanglement of the activities, and hence ethical responsibilities, of healthcare professionals and engineering professionals. The article outlines three categories of innovation: assistive technologies, telehealthcare and quasi-autonomous systems. Approaches to engineering ethics are described and applied to these innovations. Such innovations raise a number of ethical opportunities and challenges, especially as the complexity of the technology increases. In particular the design and operation of the technologies require engineers to seek closer involvement with the persons benefiting from their work. Future innovation will require engineers to have a good knowledge of human biology and psychology. More particularly, healthcare engineers will need to prioritize each person's wellbeing, agency, human relationships and ecological self rather than technology, in the same way that doctors prioritize the treatment of persons rather than their diseases.

  7. A novel polymer inclusion membrane based method for continuous clean-up of thiocyanate from gold mine tailings water.

    Science.gov (United States)

    Cho, Youngsoo; Cattrall, Robert W; Kolev, Spas D

    2018-01-05

    Thiocyanate is present in gold mine tailings waters in concentrations up to 1000mgL -1 and this has a serious environmental impact by not allowing water reuse in the flotation of gold ore. This significantly increases the consumption of fresh water and the amount of wastewater discharged in tailings dams. At the same time thiocyanate in tailings waters often leads to groundwater contamination. A novel continuous membrane-based method for the complete clean-up of thiocyanate in concentrations as high as 1000mgL -1 from its aqueous solutions has been developed. It employs a flat sheet polymer inclusion membrane (PIM) of composition 70wt% PVC, 20wt% Aliquat 336 and 10wt% 1-tetradecanol which separates counter-current streams of a feed thiocyanate solution and a 1M NaNO 3 receiving solution. The PIM-based system has been operated continuously for 45days with 99% separation efficiency. The volume of the receiving solution has been drastically reduced by recirculating it and continuously removing thiocyanate by precipitating it with in-situ generated Cu(I). The newly developed PIM-based thiocyanate clean-up method is environmentally friendly in terms of reagent use and inexpensive with respect to both equipment and running costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Cleaning of aluminum after machining with coolants

    International Nuclear Information System (INIS)

    Roop, B.

    1992-01-01

    An x-ray photoemission spectroscopic study was undertaken to compare the cleaning of the Advanced Photon Source (APS) aluminum extrusion storage ring vacuum chambers after machining with and without water soluble coolants. While there was significant contamination left by the coolants, the cleaning process was capable of removing the residue. The variation of the surface and near surface composition of samples machined either dry or with coolants was negligible after cleaning. The use of such coolants in the machining process is therefore recommended

  9. Cleaning UF membranes with simple and formulated solutions

    NARCIS (Netherlands)

    Levitsky, I.; Duek, A.; Naim, R.; Arkhangelsky, E.; Gitis, V.

    2012-01-01

    The ultrafiltration membranes fouled by proteins are typically cleaned by consecutive soaking in alkali, surfactant and oxidizing solutions. We combined all three chemicals into a formulated cleaning agent and examined its efficiency to restore the water flux without damaging the membrane or

  10. Systematic review and meta-analysis of the effectiveness of antiseptic agents for meatal cleaning in the prevention of catheter-associated urinary tract infections.

    Science.gov (United States)

    Fasugba, O; Koerner, J; Mitchell, B G; Gardner, A

    2017-03-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common healthcare-associated infections. Antiseptic cleaning of the meatal area before and during catheter use may reduce the risk of CAUTIs. To undertake a systematic review of the literature and meta-analysis of studies investigating the effectiveness of antiseptic cleaning before urinary catheter insertion and during catheter use for prevention of CAUTIs. Electronic databases were searched to identify randomized controlled trials. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated and compared across intervention and control groups using DerSimonian-Laird random-effects model. Subgroup analyses were performed. Heterogeneity was estimated using the I 2 statistic. In total, 2665 potential papers were identified; of these, 14 studies were eligible for inclusion. There was no difference in the incidence of CAUTIs when comparing antiseptic and non-antiseptic agents (pooled OR 0.90, 95% CI 0.73-1.10; P=0.31), or when comparing different agents: povidone-iodine vs routine care; povidone-iodine vs soap and water; chlorhexidine vs water; povidone-iodine vs saline; povidone-iodine vs water; and green soap and water vs routine care (P>0.05 for all). Comparison of an antibacterial agent with routine care indicated near significance (P=0.06). There was no evidence of heterogeneity (I 2 =0%; P>0.05). Subgroup analyses showed no difference in the incidence of CAUTIs in terms of country, setting, risk of bias, sex and frequency of administration. There were no differences in CAUTI rates, although methodological issues hamper generalizability of this finding. Antibacterial agents may prove to be significant in a well-conducted study. The present results provide good evidence to inform infection control guidelines in catheter management. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Bifunctional Au@TiO_2 core–shell nanoparticle films for clean water generation by photocatalysis and solar evaporation

    International Nuclear Information System (INIS)

    Huang, Jian; He, Yurong; Wang, Li; Huang, Yimin; Jiang, Baocheng

    2017-01-01

    Highlights: • Au@TiO_2 core-shell nanoparticles were prepared in this study. • Bifunctional films for photocatalysis and solar evaporation were designed. • The evaporation and photodegradation with core-shell structures were investigated. - Abstract: With water scarcity becoming an increasingly critical issue for modern society, solar seawater desalination represents a promising approach to mitigating water shortage. In addition, solar seawater desalination shows great potential for mitigating the energy crisis due to its high photo-thermal conversion efficiency. However, the increasing contamination of seawater makes it difficult to generate clean water through simple desalination processes. In this work, clean water is generated by a newly designed bifunctional Au@TiO_2 core-shell nanoparticle film with a high photo-thermal conversion efficiency that is capable of photocatalysis and solar evaporation for seawater desalination. Bifunctional films of Au@TiO_2 core-shell nanoparticles with good stability were prepared. It was found that the formation of the core-shell structures played a key role in promoting the photo-thermal conversion efficiency and the evaporation of seawater, while the photocatalytic function demonstrated herein could contribute to the purification of polluted seawater. Furthermore, the film structure can serve to concentrate the NPs for the photo-reaction, as well as heat for water evaporation, improving both the photo-reaction efficiency and photo-thermal conversion efficiency. This efficient approach to solar seawater desalination, which combines evaporation with the photodegradation of pollutants, could help to address the dual issues of water scarcity and water pollution.

  12. Biochar-based water treatment systems as a potential low-cost and sustainable technology for clean water provision.

    Science.gov (United States)

    Gwenzi, Willis; Chaukura, Nhamo; Noubactep, Chicgoua; Mukome, Fungai N D

    2017-07-15

    Approximately 600 million people lack access to safe drinking water, hence achieving Sustainable Development Goal 6 (Ensure availability and sustainable management of water and sanitation for all by 2030) calls for rapid translation of recent research into practical and frugal solutions within the remaining 13 years. Biochars, with excellent capacity to remove several contaminants from aqueous solutions, constitute an untapped technology for drinking water treatment. Biochar water treatment has several potential merits compared to existing low-cost methods (i.e., sand filtration, boiling, solar disinfection, chlorination): (1) biochar is a low-cost and renewable adsorbent made using readily available biomaterials and skills, making it appropriate for low-income communities; (2) existing methods predominantly remove pathogens, but biochars remove chemical, biological and physical contaminants; (3) biochars maintain organoleptic properties of water, while existing methods generate carcinogenic by-products (e.g., chlorination) and/or increase concentrations of chemical contaminants (e.g., boiling). Biochars have co-benefits including provision of clean energy for household heating and cooking, and soil application of spent biochar improves soil quality and crop yields. Integrating biochar into the water and sanitation system transforms linear material flows into looped material cycles, consistent with terra preta sanitation. Lack of design information on biochar water treatment, and environmental and public health risks constrain the biochar technology. Seven hypotheses for future research are highlighted under three themes: (1) design and optimization of biochar water treatment; (2) ecotoxicology and human health risks associated with contaminant transfer along the biochar-soil-food-human pathway, and (3) life cycle analyses of carbon and energy footprints of biochar water treatment systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Optimizing UF Cleaning in UF-SWRO System Using Red Sea Water

    KAUST Repository

    Bahshwan, Mohanad

    2012-01-01

    in the production cost. This research focused on increasing the plant's efficiency through optimizing the cleaning protocol without jeopardizing the effectiveness of the cleaning process. For that purpose, the design of experiment (DOE) focused on testing

  14. Clean power from deserts. The DESERTEC concept for energy, water and climate security

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    The main challenge for the future is to reclaim energy from renewable and clean sources in environmentally compatible ways. Here the deserts of the earth can play a key role. They receive about 700 times more energy from the sun than humankind consumes by burning fossil fuels, day by day. Deserts are the places with the best solar radiation conditions and with the least possible impact of collector deployment onto the biosphere on earth. In deserts, clean power can be produced by solar thermal power plants (CSP) in a truly sustainable way and at any volume of conceivable demand. Power can be transmitted with low losses by high voltage direct current (HVDC) lines to more than 90% of the world's population. This gives the deserts a new role: Together with the many other forms of accessible renewable energy the newly utilized desert would enable us to replace fossil fuels and thus end the ongoing destruction of our natural living conditions. To put this into practice, countries with deserts, countries with high energy demand and countries with technology competence must cooperate. This is an opportunity for the Mediterranean riparian regions of Europe, the Middle East and North Africa (EUMENA) to form a community for energy, water and climate security. With the political will, EUMENA countries could now launch 'EUMENA-DESERTEC' Program, to bring humankind back into balance with its environment, by putting deserts and technology into service for energy, water and climate security. This would be an important step towards creating a truly sustainable civilization.

  15. ANALYSIS ON TECHNOLOGICAL PROCESSES CLEANING OIL PIPELINES

    Directory of Open Access Journals (Sweden)

    Mariana PǍTRAŞCU

    2015-05-01

    Full Text Available In this paper the researches are presented concerning the technological processes of oil pipelines.We know several technologies and materials used for cleaning the sludge deposits, iron and manganese oxides, dross, stone, etc.de on the inner walls of drinking water pipes or industries.For the oil industry, methods of removal of waste materials and waste pipes and liquid and gas transport networks are operations known long, tedious and expensive. The main methods and associated problems can be summarized as follows: 1 Blowing with compressed air.2 manual or mechanical brushing, sanding with water or dry.3 Wash with water jet of high pressure, solvent or chemical solution to remove the stone and hard deposits.4 The combined methods of cleaning machines that use water jets, cutters, chains, rotary heads cutters, etc.

  16. Fabrication of superhydrophobic copper surface on various substrates for roll-off, self-cleaning, and water/oil separation.

    Science.gov (United States)

    Sasmal, Anup Kumar; Mondal, Chanchal; Sinha, Arun Kumar; Gauri, Samiran Sona; Pal, Jaya; Aditya, Teresa; Ganguly, Mainak; Dey, Satyahari; Pal, Tarasankar

    2014-12-24

    Superhydrophobic surfaces prevent percolation of water droplets and thus render roll-off, self-cleaning, corrosion protection, etc., which find day-to-day and industrial applications. In this work, we developed a facile, cost-effective, and free-standing method for direct fabrication of copper nanoparticles to engender superhydrophobicity for various flat and irregular surfaces such as glass, transparency sheet (plastic), cotton wool, textile, and silicon substrates. The fabrication of as-prepared superhydrophobic surfaces was accomplished using a simple chemical reduction of copper acetate by hydrazine hydrate at room temperature. The surface morphological studies demonstrate that the as-prepared surfaces are rough and display superhydrophobic character on wetting due to generation of air pockets (The Cassie-Baxter state). Because of the low adhesion of water droplets on the as-prepared surfaces, the surfaces exhibited not only high water contact angle (164 ± 2°, 5 μL droplets) but also superb roll-off and self-cleaning properties. Superhydrophobic copper nanoparticle coated glass surface uniquely withstands water (10 min), mild alkali (5 min in saturated aqueous NaHCO3 of pH ≈ 9), acids (10 s in dilute HNO3, H2SO4 of pH ≈ 5) and thiol (10 s in neat 1-octanethiol) at room temperature (25-35 °C). Again as-prepared surface (cotton wool) was also found to be very effective for water-kerosene separation due to its superhydrophobic and oleophilic character. Additionally, the superhydrophobic copper nanoparticle (deposited on glass surface) was found to exhibit antibacterial activity against both Gram-negative and Gram-positive bacteria.

  17. Biological decomposition of aqueous solutions from soil cleaning

    International Nuclear Information System (INIS)

    Kniebusch, M.M.; Sekoulov, I.

    1993-01-01

    The biological cleaning of process water from soil cleaning and from contaminated groundwater required the development of new types of reaction systems. With the introduced membrane biofilm reactor, even substances difficult to decompose can be removed from contaminated water. Previous investigations of the elimination of pyrene in the presence of n-hexadecane show an optimum temperature at 30 C. An increase of scale is possible based on the invesstigations carried out on the aerobic biological decomposition of polycyclic aromatic hydrocarbons. (orig.) [de

  18. Proposal for the award of a contract for the upgrade of clean and waste water systems for the LHC

    CERN Document Server

    2003-01-01

    This document concerns the award of a contract for the upgrade of clean and waste water systems for the LHC. Following a market survey carried out among 61 firms in thirteen Member States, a call for tenders (IT-3176/ST/LHC) was sent on 28 May 2003 to four firms and four consortia in six Member States. By the closing date, CERN had received six tenders from two firms and four consortia in five Member States. The Finance Committee is invited to agree to the negotiation of a contract with ABB (CH), the lowest bidder, for the upgrade of clean and waste water systems for the LHC for a total amount of 920 000 Swiss francs, not subject to revision. The firm has indicated the following distribution by country of the contract value covered by this adjudication proposal: DE - 35%; FR - 31%; CH - 17%; SE - 13%; DK - 4%.

  19. Chemical cleaning of Dresden Unit 1: Final report

    International Nuclear Information System (INIS)

    1986-05-01

    The introduction of NS-1 solvent into the full primary system of Dresden Unit-1 nuclear power reactor on September 12, 1984, represented the culmination of several years of development, testing, planning, and construction. The requirement was to dissolve the highly radioactive deposits of primarily nickel ferrite without any corrosion which might compromise the reactor systems. During the actual cleaning with the NS-1 solvent, the chemical condition of the circulating solvent was measured. Iron, nickel, and radioactive cobalt all dissolved smoothly. The amount of copper in solution decreased in concentration, verifying expectations that metallic copper would plate on to clean metal surfaces. A special rinse formulation was employed after the primary cleaning steps and the ''lost'' copper was thus redissolved and removed from the system. After the cleaning was complete and the reactor had been refilled with pure water, radiation levels were measured. The most accurate of these measurements gave decontamination factors ranging well above 100, which indicated a significant removal of the radioactive deposits, and demonstrated the success of this project. Treatment of the radioactive liquid wastes from this operation required volume reduction and water purification. The primary method of processing the spent cleaning solvent and rinse water was evaporation. The resulting concentrate has been stored as a liquid, awaiting solidification to allow burial at a designated site. Water which was separated during evaporation, along with the dilute rinses, was processed by various chemical means, reevaporated, treated with activated carbon, and/or demineralized before its radionuclide and chemical content was low enough to allow it to be returned to Dresden Station for treatment or disposal. 60 figs., 31 tabs

  20. A clean bill of health? The efficacy of an NHS commissioned outsourced police custody healthcare service.

    Science.gov (United States)

    de Viggiani, Nick

    2013-08-01

    Police custody healthcare services for detainees in the UK are most commonly outsourced to independent healthcare providers who employ custody nurses and forensic physicians to deliver forensic healthcare services. A pilot was introduced in 2008 by the Department of Health to explore the efficacy of commissioning custody healthcare via the NHS, in the wake of the 2005-2006 shift of prison healthcare to the NHS. The objective was to improve quality and accountability through NHS commissioning and the introduction of NHS governance to the management and delivery of custody healthcare. This article discusses key themes that arose from the project evaluation, which focused on the commissioning relationship between the police, the NHS commissioner and the private healthcare provider. The evaluation observed an evolving relationship between the police, the local NHS and the front-line nurses, which was complicated by the quite distinctive professional values and ideologies operating, with their contrasting organisational imperatives and discordant values and principles. A key challenge for commissioners is to develop synergy between operational and strategically located stakeholders so that they can work effectively towards common goals. Government policy appears to remain focused on creating safe, supportive and humane custody environments that balance criminal justice and health imperatives and support the rights and needs of detainees, victims, professionals and the public. This remains an ambitious agenda and presents a major challenge for new criminal justice health partnerships. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. Operation Clean Feather: Reducing oil pollution in Newfoundland waters

    International Nuclear Information System (INIS)

    Chardine, J.W.; Pelly, G.

    1994-01-01

    Oil pollution of marine waters around Newfoundland, and particularly in the vicinity of Placentia Bay, is a frequent occurrence. Many oiled seabirds are found on beaches in the bay, particularly in winter. The most likely pollution sources are ship operators who dump waste oils from bilges and slop tanks. In an effort to reduce the chronic discharge of waste oil into Placentia Bay, and thus the incidence of bird oiling, Operation Clean Feather was launched in 1991-92 and consisted of weekly surveys of Placentia Bay beaches, sampling of oil from vessels using the bay and from oiled birds and beaches, and experimentation to determine possible recovery rates of birds oiled at sea. The operation was considered a success at a number of levels. Significant reductions in numbers of oiled birds were noted in both 1991 and 1992 compared to 1989 or 1990. Estimated oil-related mortality was reduced to ca 25% of levels seen in the two years prior to the operation. The operation also provided the opportunity to test and refine an organizational framework designed to deal with the problem of chronic oil pollution reports. Communication efforts heightened the awareness of the oil pollution problem in Newfoundland waters. These efforts included distribution of pamphlets in various languages to ship operators, describing the seriousness of oil-related marine bird mortality and warning of the substantial fines that can be imposed under the Canada Shipping Act. 6 refs., 3 figs., 1 tab

  2. Robotic cleaning of a spent fuel pool

    International Nuclear Information System (INIS)

    Roman, H.T.; Marian, F.A.; Silverman, E.B.; Barkley, V.P.

    1987-01-01

    Spent fuel pools at nuclear power plants are not cleaned routinely, other than by purifying the water that they contain. Yet, debris can collect on the bottom of a pool and should be removed prior to fuel transfer. At Public Service Electric and Gas Company's Hope Creek Nuclear Power Plant, a submersible mobile robot - ARD Corporation's SCAVENGER - was used to clean the bottom of the spent fuel pool prior to initial fuel loading. The robotic device was operated remotely (as opposed to autonomously) with a simple forward/reverse control, and it cleaned 70-80% of the pool bottom. This paper reports that a simple cost-benefit analysis shows that the robotic device would be less expensive, on a per mission basis, than other cleaning alternatives, especially if it were used for other similar cleaning operations throughout the plant

  3. Manual cleaning of hospital mattresses: an observational study comparing high- and low-resource settings.

    Science.gov (United States)

    Hopman, J; Hakizimana, B; Meintjes, W A J; Nillessen, M; de Both, E; Voss, A; Mehtar, S

    2016-01-01

    Hospital-associated infections (HAIs) are more frequently encountered in low- than in high-resource settings. There is a need to identify and implement feasible and sustainable approaches to strengthen HAI prevention in low-resource settings. To evaluate the biological contamination of routinely cleaned mattresses in both high- and low-resource settings. In this two-stage observational study, routine manual bed cleaning was evaluated at two university hospitals using adenosine triphosphate (ATP). Standardized training of cleaning personnel was achieved in both high- and low-resource settings. Qualitative analysis of the cleaning process was performed to identify predictors of cleaning outcome in low-resource settings. Mattresses in low-resource settings were highly contaminated prior to cleaning. Cleaning significantly reduced biological contamination of mattresses in low-resource settings (P cleaning in both the high- and low-resource settings seemed comparable. Cleaning with appropriate type of cleaning materials reduced the contamination of mattresses adequately. Predictors for mattresses that remained contaminated in a low-resource setting included: type of product used, type of ward, training, and the level of contamination prior to cleaning. In low-resource settings mattresses were highly contaminated as noted by ATP levels. Routine manual cleaning by trained staff can be as effective in a low-resource setting as in a high-resource setting. We recommend a multi-modal cleaning strategy that consists of training of domestic services staff, availability of adequate time to clean beds between patients, and application of the correct type of cleaning products. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Ultrasonic Cleaning of Nuclear Steam Generator by Micro Bubble

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Woo Tae [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of); Kim, Sang Tae; Yoon, Sang Jung [Sae-An Engineering Co., Seoul (Korea, Republic of)

    2012-05-15

    In this paper, we present ultrasonic cleaning technology for a nuclear steam generator using micro bubble. We could extend the boundary of ultrasonic cleaning by using micro bubbles in water. Ultrasonic energy measured was increased about 5 times after the generation of micro bubbles in water. Furthermore, ultrasound energy was measured to be strong enough to create cavitation even though the ultrasound sensor was about 2 meters away from the ultrasonic transducer

  5. Clean Water Act (Section 404) and Rivers and Harbors Act (Sections 9 and 10)

    International Nuclear Information System (INIS)

    1992-01-01

    This Reference Book contains a current copy of the Clean Water Act (Section 404) and the Rivers and Harbors Act (Sections 9 and 10) and those regulations that implement those sections of the statutes and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, IH-231 (FTS 896-2609 or Commercial 202/586-2609)

  6. Solution-derived photocatalytic films for environmental cleaning applications

    International Nuclear Information System (INIS)

    Štangar, U Lavrencic; Kete, M; Šuligoj, A; Tasbihi, M

    2012-01-01

    When photocatalytic water treatment is concerned, suspended catalyst in the aqueous phase is usually more efficient than immobilized on an inert support, but in the former case an undesirable separation/recycling step is needed. We have therefore concentrated on the preparation of immobilized catalysts in the form of films on glass and aluminium supports. The low-temperature sol-gel processing route to obtain transparent thin TiO 2 /SiO 2 films for self-cleaning purposes and thicker TiO 2 /SiO 2 coatings for efficient removal of pollutants in water and air are presented. The synthesis is based on a production of a nanocrystalline titania sol with a silica binder that after deposition does not require thermal treatment at high temperatures. Depending on the target application, some specific synthesis parameters and photocatalytic activity testing conditions are illustrated. For water-cleaning coatings fast kinetics is required, which was achieved by addition of a highly active titania powder into the sol. The same preparation procedure was used to prepare efficient air-cleaning coatings. On the other hand, self-cleaning films were thinner and transparent to keep the original appearance of the substrate and they solidified at ambient conditions. Advanced methodologies to evaluate photocatalytic activity of the films were applied.

  7. Infrasonic backpulsed membrane cleaning of micro- and ...

    African Journals Online (AJOL)

    2011-08-29

    Aug 29, 2011 ... become prominent in water treatment for domestic and indus- trial water ... fouling and cleaning in a reverse osmosis (RO) system, and showed that the .... used to make yeast suspensions with concentrations of 1 g/ℓ. Alumina ...

  8. Interpretation of key points of "regulation for cleaning and disinfection management of environmental surface in healthcare facilities"%《医疗机构环境表面清洁与消毒管理规范》重点诠释

    Institute of Scientific and Technical Information of China (English)

    倪晓平

    2017-01-01

    医疗机构环境清洁质量是医院相关性感染预防与控制的基础,污染的环境表面是易感患者获得感染性病原微生物的重要来源;强化的终末消毒措施可减少多药耐药菌(MDROs)和艰难梭菌(CD)感染发病10.00%~30.00%;为此,国家卫计委于2016年底发布《医疗机构环境表面清洁与消毒管理规范》,成为我国首部针对环境感染控制的卫生行业标准;为了帮助广大读者更好地理解《规范》,本文就《规范》编写背景与目的,以及涉及环境清洁理念、环境清洁管理,以及环境清洁实践等重要内容进行诠释.%The quality of environmental cleaning within healthcare facilities is the foundation for prevention and control of health care-associated infections (HAIs).The contaminated environmental surface contributes patients acquired HAIs.Enhanced terminal disinfection can reduce the incidence rates of multidrug-resistant organisms (MDROS) and Clostridium difficile infections by 10.00%~30.00%.Thus, the National Health and Family Planning Commission of the People's republic of China issued the Regulation for cleaning and disinfection management of environmental surface in healthcare facilities in 2016, which is the first standard for control of environmental infection in China.In order to help readers to understand this regulation, the paper interprets the background and purpose of drafting the regulation and the key contents involving the environmental cleaning ideas and environmental cleaning management as well as the environmental cleaning practice.

  9. Clean water billing monitoring system using flow liquid meter sensor and SMS gateway

    Science.gov (United States)

    Fahmi, F.; Hizriadi, A.; Khairani, F.; Andayani, U.; Siregar, B.

    2018-03-01

    Public clean water company (PDAM) as a public service is designed and organized to meet the needs of the community. Currently, the number of PDAM subscribers is very big and will continue to grow, but the service and facilities to customers are still done conventionally by visiting the customer’s home to record the last position of the meter. One of the problems of PDAM is the lack of disclosure of PDAM customers’ invoice because it is only done monthly. This, of course, makes PDAM customers difficult to remember the date of payment of water account. Therefore it is difficult to maintain the efficiency. The purpose of this research is to facilitate customers of PDAM water users to know the details of water usage and the time of payment of water bills easily. It also facilitates customers in knowing information related to the form of water discharge data used, payment rates, and time grace payments using SMS Gateway. In this study, Flow Liquid Meter Sensor was used for data retrieval of water flowing in the piping system. Sensors used to require the help of Hall Effect sensor that serves to measure the speed of water discharge and placed on the pipe that has the same diameter size with the sensor diameter. The sensor will take the data from the rate of water discharge it passes; this data is the number of turns of the mill on the sensor. The results of the tests show that the built system works well in helping customers know in detail the amount of water usage in a month and the bill to be paid

  10. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    Directory of Open Access Journals (Sweden)

    Robert Clifford

    Full Text Available The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal correlates with cleaning efficacy (absence of molecular or cultivable biomaterial and whether one brief educational intervention improves cleaning outcomes.Before-after trial.Newly built community hospital.90 minute training refresher with surface-specific performance results.Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention and assessments continued for another eight consecutive months.1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant. For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant, and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016. For nonspecific biomaterial on surfaces: a removal of cultivable Gram-negatives (GN trended toward improvement (P = 0.056; b removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning worsened (P = 0.017; c removal of PCR-based detection of bacterial DNA improved (P = 0.046, but acquisition worsened (P = 0.003; d cleaning thoroughness and efficacy were not correlated.At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences.

  11. 75 FR 39683 - Clean Water Act Section 312(b): Notice Seeking Stakeholder Input on Petition and Other Request To...

    Science.gov (United States)

    2010-07-12

    ... the Earth (FOE) and another separate request for rulemaking under section 312 of the Clean Water Act... performance standards for vessel sewage treatment devices under the CWA. The rulemaking petition from FOE also... Petition On April 28, 2009, pursuant to the Administrative Procedure Act, Friends of the Earth (FOE...

  12. Algal Turf Scrubbers: Cleaning Water while Capturing Solar Energy for Bio fuel Production

    International Nuclear Information System (INIS)

    Jeffrey Bannon, J.; Adey, W.

    2010-01-01

    Algal Turfs are bio diverse communities of unicellular to filamentous algae of all major algal phyla. Algal Turf Scrubbers (ATS) are bioengineered ecosystems dominated by algal turfs. They clean water to very high quality, and remove CO 2 from the atmosphere by capturing solar energy at rates 10 times that of agriculture and 50 times that of forestry. Since they are controlled ecosystems, using local algae, ATS does not suffer the major disadvantages of agricultural crops, which for maximum efficiency require fertilizers, herbicides and pesticides. ATS removes CO 2 from water and the atmosphere, and can be configured to remove CO 2 from power plant stack gases. As a normal part of operations, ATS removes heavy metals, break down toxic hydrocarbons, and oxygenates treated waters. ATS systems are capable of removing nitrogen and phosphorous from surface waters in the mid latitude US at $0.60/kg and $10.60/kg respectively (10% of the cost certified by the Chesapeake Bay Commission), and independently producing an energy product at $0.85/gallon. Given a nutrient credit system for rewarding nutrient removal from rivers and lakes, this price can be driven down to below $.40/gallon. Conservatively ATS can produce the equivalent of US imported oil on less than 30 M acres of land along major rivers

  13. An outbreak of Legionnaires disease associated with a decorative water wall fountain in a hospital.

    Science.gov (United States)

    Haupt, Thomas E; Heffernan, Richard T; Kazmierczak, James J; Nehls-Lowe, Henry; Rheineck, Bruce; Powell, Christine; Leonhardt, Kathryn K; Chitnis, Amit S; Davis, Jeffrey P

    2012-02-01

    To detect an outbreak-related source of Legionella, control the outbreak, and prevent additional Legionella infections from occurring. Epidemiologic investigation of an acute outbreak of hospital-associated Legionnaires disease among outpatients and visitors to a Wisconsin hospital. Patients with laboratory-confirmed Legionnaires disease who resided in southeastern Wisconsin and had illness onsets during February and March 2010. Patients with Legionnaires disease were interviewed using a hypothesis-generating questionnaire. On-site investigation included sampling of water and other potential environmental sources for Legionella testing. Case-finding measures included extensive notification of individuals potentially exposed at the hospital and alerts to area healthcare and laboratory personnel. Laboratory-confirmed Legionnaires disease was diagnosed in 8 patients, all of whom were present at the same hospital during the 10 days prior to their illness onsets. Six patients had known exposure to a water wall-type decorative fountain near the main hospital entrance. Although the decorative fountain underwent routine cleaning and maintenance, high counts of Legionella pneumophila serogroup 1 were isolated from cultures of a foam material found above the fountain trough. This outbreak of Legionnaires disease was associated with exposure to a decorative fountain located in a hospital public area. Routine cleaning and maintenance of fountains does not eliminate the risk of bacterial contamination. Our findings highlight the need to evaluate the safety of water fountains installed in any area of a healthcare facility.

  14. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.

  15. Nonpoint Source Pollution: Agriculture, Forestry, and Mining. Instructor Guide. Working for Clean Water: An Information Program for Advisory Groups.

    Science.gov (United States)

    Buskirk, E. Drannon, Jr.

    Nonpoint sources of pollution have diffuse origins and are major contributors to water quality problems in both urban and rural areas. Addressed in this instructor's manual are the identification, assessment, and management of nonpoint source pollutants resulting from mining, agriculture, and forestry. The unit, part of the Working for Clean Water…

  16. Evaluation of ozonated water using ASTM E1174 for standardized testing of handwash formulations for healthcare personnel.

    Science.gov (United States)

    Nakamura, K; Saito, K; Kashiwazaki, J; Aoyagi, T; Arai, K; Hara, Y; Kobari, S; Mori, H; Ohashi, K; Takano, Y; Kaku, M; Kanemitsu, K

    2018-02-13

    Removal of bacteria by handwashing with ozonated water was evaluated using the ASTM E1174 standard test method. Thirty healthy volunteers were assigned randomly to three groups: ozonated water, antimicrobial soap and water, and non-antimicrobial soap and water. A 3 log 10  cfu reduction was achieved by washing hands with ozonated water or antimicrobial soap and water. However, ozonated water was not significantly superior to non-antimicrobial soap and water. Ozonated water may remove bacteria from the hands to at least a similar extent as that by non-antimicrobial soap and water in the absence of visible dirt or body fluid contamination. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Alberta's clean energy future

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    This paper deals with the future of clean energy in Alberta. With the present economic growth of the oil sands industry in Alberta, it is expected that there will be very considerable increases in job opportunities and GDP in both Canada and US. The challenges include high-energy demand and reduction of the carbon footprint. Alberta has adopted certain approaches to developing renewable and alternate forms of energy as well as to increasing the efficiency of present energy use and raising environmental consciousness in energy production. Three areas where the effects of clean energy will be felt are energy systems, climate change, and regional impacts, for instance on land, water, and wildlife. Alberta's regulatory process is shown by means of a flow chart. Aspects of oil sands environmental management include greenhouse gas targets, air quality assurance, and water quality monitoring, among others. Steps taken by Alberta to monitor and improve air quality and water management are listed. In conclusion, the paper notes that significant amounts of money are being pumped into research and development for greenhouse gas and water management projects.

  18. Atmosphere self-cleaning under humidity conditions and influence of the snowflakes and artificial light interaction for water dissociation simulated by the means of COMSOL

    Science.gov (United States)

    Cocean, A.; Cocean, I.; Cazacu, M. M.; Bulai, G.; Iacomi, F.; Gurlui, S.

    2018-06-01

    The self-cleaning of the atmosphere under humidity conditions is observed due to the change in emission intensity when chemical traces are investigated with DARLIOES - the advanced LIDAR based on space- and time-resolved RAMAN and breakdown spectroscopy in conditions of consistent humidity of atmosphere. The determination was performed during the night, in the wintertime under conditions of high humidity and snowfall, in urban area of Iasi. The change in chemical composition of the atmosphere detected was assumed to different chemical reactions involving presence of the water. Water dissociation that was registered during spectral measurements is explained by a simulation of the interaction between artificial light and snowflakes - virtually designed in a spherical geometry - in a wet air environment, using COMSOL Multiphysics software. The aim of the study is to explain the decrease or elimination of some of the toxic trace chemical compounds in the process of self-cleaning in other conditions than the sun light interaction for further finding application for air cleaning under artificial conditions.

  19. Efficacy of a hospital-wide environmental cleaning protocol on hospital-acquired methicillin-resistant Staphylococcus aureus rates.

    Science.gov (United States)

    Watson, Paul Andrew; Watson, Luke Robert; Torress-Cook, Alfonso

    2016-07-01

    Environmental contamination has been associated with over half of methicillin-resistant Staphylococcus aureus (MRSA) outbreaks in hospitals. We explored if a hospital-wide environmental and patient cleaning protocol would lower hospital acquired MRSA rates and associated costs. This study evaluates the impact of implementing a hospital-wide environmental and patient cleaning protocol on the rate of MRSA infection and the potential cost benefit of the intervention. A retrospective, pre-post interventional study design was used. The intervention comprised a combination of enhanced environmental cleaning of high touch surfaces, daily washing of patients with benzalkonium chloride, and targeted isolation of patients with active infection. The rate of MRSA infection per 1000 patient days (PD) was compared with the rate after the intervention (Steiros Algorithm ® ) was implemented. A cost-benefit analysis based on the number of MRSA infections avoided was conducted. The MRSA rates decreased by 96% from 3.04 per 1000 PD to 0.11 per 1000 PD ( P reduction in MRSA infections, avoided an estimated $1,655,143 in healthcare costs. Implementation of this hospital-wide protocol appears to be associated with a reduction in the rate of MRSA infection and therefore a reduction in associated healthcare costs.

  20. Effects of beach cast cleaning on beach quality, microbial food web, and littoral macrofaunal biodiversity

    Science.gov (United States)

    Malm, Torleif; Råberg, Sonja; Fell, Sabine; Carlsson, Per

    2004-06-01

    At the end of the summer, drifting filamentous red algae cover shallow bottoms and accumulate in huge cast walls on the open shores of the non-tidal central Baltic Sea. The hypotheses that beach cleaning increases water clarity, decreases the organic content of the sand, and increases the species diversity in the shallow zone closest to the shore, were tested through field investigations and experiments. Cleaned shorelines were compared with un-cleaned shorelines at two sites with different intensity of beach cleaning in a rural area of SE Sweden. The results show that water clarity was significantly increased off the intensively cleaned beach but not off the moderately cleaned one. Similarly, the total leakage of nitrogenous compounds decreased off the intensively cleaned beach, but not off the moderately cleaned. The organic content of the sand was lower on both cleaned beaches compared with nearby un-cleaned beaches. The total animal biomass was significantly lower on the intensively cleaned beach compared with the un-cleaned beach, but the moderately cleaned beach gave no such effect. The difference in biodiversity and community structure between cleaned and un-cleaned beaches was insignificant. The most obvious difference in species composition was a much higher number of planktivore opossum shrimps of the genus Mysis and Praunus on the un-cleaned beaches. The bacterial production and the amount of ciliates larger than 20 mm were also higher on un-cleaned beaches, indicating that the microbial food web off the un-cleaned beaches is stimulated by the discharge of decomposing algal material. The conclusion of the study is that mechanical cleaning reduces the organic content of the beach sand and may change the water quality and microbial production, but the effect on the macrofaunal biodiversity is insignificant.

  1. Fouling and cleaning of seawater reverse osmosis membranes in Kalpakkam Nuclear Desalination Plant

    International Nuclear Information System (INIS)

    Murugan, V.; Rajanbabu, K.; Tiwari, S.A.; Balasubramanian, C.; Yadav, Manoj Kumar; Dangore, A.Y.; Prabhakar, S.; Tewari, P.K.

    2005-01-01

    Seawater reverse osmosis plant of 1800 m 3 /day capacity is a part of 6300 m 3 /day capacity Nuclear Desalination Demonstration Project, at Kalpakkam. The plant was commissioned in October 2002 and is in continuous operation. This paper deals with types of foulants, membrane cleaning procedures and the improvement in the reverse osmosis system after cleaning. This paper also describes analysis of foulants which may consist of adsorbed organic compounds, particulate matter, microorganisms, metallic oxides and chemical cleaning procedure to be adopted, which is characteristics of sea water used as the membrane foulant is very much specific with respect to the sea water constituents. The cleaning of the membranes in Kalpakkam Nuclear Desalination plant were taken up as the quality of permeate deteriorated and differential pressure across membrane had gone-up. This paper essentially deals with selection of cleaning chemicals, the experience gained in cleaning procedure adopted and effects of cleaning for the membrane system. (author)

  2. Epidemiology of occupational injury among cleaners in the healthcare sector.

    Science.gov (United States)

    Alamgir, Hasanat; Yu, Shicheng

    2008-09-01

    The cleaning profession has been associated with multiple ergonomic and chemical hazards which elevate the risk for occupational injury. This study investigated the epidemiology of occupational injury among cleaners in healthcare work settings in the Canadian province of British Columbia. Incidents of occupational injury among cleaners, resulting in lost time from work or medical care, over a period of 1 year in two healthcare regions were extracted from a standardized operational database and with person-years obtained from payroll data. Detailed analysis was conducted using Poisson regression modeling. A total of 145 injuries were identified among cleaners, with an annual incidence rate of 32.1 per 100 person-years. After adjustment for age, gender, subsector, facility, experience and employment status, Poisson regression models demonstrated that a significantly higher relative risk (RR) of all injury, musculoskeletal injury and cuts was associated with cleaning work in acute care facilities, compared with long-term care facilities. Female cleaners were at a higher RR of all injuries and contusions than male cleaners. A lower risk of all injury and allergy and irritation incidents among part-time or casual workers was found. Cleaners with >10 years of experience were at significantly lower risk for all injury, contusion and allergy and irritation incidents. Cleaners were found to be at an elevated risk of all injury categories compared with healthcare workers in general.

  3. Piped water consumption in Ghana: A case study of temporal and spatial patterns of clean water demand relative to alternative water sources in rural small towns.

    Science.gov (United States)

    Kulinkina, Alexandra V; Kosinski, Karen C; Liss, Alexander; Adjei, Michael N; Ayamgah, Gilbert A; Webb, Patrick; Gute, David M; Plummer, Jeanine D; Naumova, Elena N

    2016-07-15

    Continuous access to adequate quantities of safe water is essential for human health and socioeconomic development. Piped water systems (PWSs) are an increasingly common type of water supply in rural African small towns. We assessed temporal and spatial patterns in water consumption from public standpipes of four PWSs in Ghana in order to assess clean water demand relative to other available water sources. Low water consumption was evident in all study towns, which manifested temporally and spatially. Temporal variability in water consumption that is negatively correlated with rainfall is an indicator of rainwater preference when it is available. Furthermore, our findings show that standpipes in close proximity to alternative water sources such as streams and hand-dug wells suffer further reductions in water consumption. Qualitative data suggest that consumer demand in the study towns appears to be driven more by water quantity, accessibility, and perceived aesthetic water quality, as compared to microbiological water quality or price. In settings with chronic under-utilization of improved water sources, increasing water demand through household connections, improving water quality with respect to taste and appropriateness for laundry, and educating residents about health benefits of using piped water should be prioritized. Continued consumer demand and sufficient revenue generation are important attributes of a water service that ensure its function over time. Our findings suggest that analyzing water consumption of existing metered PWSs in combination with qualitative approaches may enable more efficient planning of community-based water supplies and support sustainable development. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Cleaning, disassembly, and requalification of the FFTF in vessel handling machine

    International Nuclear Information System (INIS)

    Coops, W.J.

    1977-10-01

    The Engineering Model In Vessel Handling Machine (IVHM) was successfully removed, cleaned, disassembled, inspected, reassembled and reinstalled into the sodium test vessel at Richland, Washington. This was the first time in the United States a full size operational sodium wetted machine has been cleaned by the water vapor nitrogen process and requalified for operation. The work utilized an atmospheric control system during removal, a tank type water vapor nitrogen cleaning system and an open ''hands on'' disassembly and assembly stand. Results of the work indicate the tools, process and equipment are adequate for the non-radioactive maintenance sequence. Additionally, the work proves that a machine of this complexity can be successfully cleaned, maintained and re-used without the need to replace a large percentage of the sodium wetted parts

  5. Oxygen transfer rate estimation in oxidation ditches from clean water measurements.

    Science.gov (United States)

    Abusam, A; Keesman, K J; Meinema, K; Van Straten, G

    2001-06-01

    Standard methods for the determination of oxygen transfer rate are based on assumptions that are not valid for oxidation ditches. This paper presents a realistic and simple new method to be used in the estimation of oxygen transfer rate in oxidation ditches from clean water measurements. The new method uses a loop-of-CSTRs model, which can be easily incorporated within control algorithms, for modelling oxidation ditches. Further, this method assumes zero oxygen transfer rates (KLa) in the unaerated CSTRs. Application of a formal estimation procedure to real data revealed that the aeration constant (k = KLaVA, where VA is the volume of the aerated CSTR) can be determined significantly more accurately than KLa and VA. Therefore, the new method estimates k instead of KLa. From application to real data, this method proved to be more accurate than the commonly used Dutch standard method (STORA, 1980).

  6. McClean Lake. Site Guide

    International Nuclear Information System (INIS)

    2016-09-01

    Located over 700 kilometers northeast of Saskatoon, Areva's McClean Lake site is comprised of several uranium mines and one of the most technologically advanced uranium mills in the world - the only mill designed to process high-grade uranium ore without dilution. Areva has operated several open-pit uranium mines at the McClean Lake site, and is evaluating future mines at and near the site. The McClean Lake mill has recently undergone a multimillion-dollar upgrade and expansion, which has doubled its annual production capacity of uranium concentrate to 24 million pounds. It is the only facility in the world capable of processing high-grade uranium ore without diluting it. The mill processes the ore from the Cigar Lake mine, the world's second largest and highest-grade uranium mine. The McClean Lake site operates 365 days a year on a week-in/week-out rotation schedule for workers, over 50% of whom reside in northern Saskatchewan communities. Tailings are waste products resulting from milling uranium ore. This waste is made up of leach residue solids, waste solutions and chemical precipitates that are carefully engineered for long-term disposal. The TMF serves as the repository for all resulting tailings. This facility allows proper waste management, which minimizes potential adverse environmental effects. Mining projections indicate that the McClean Lake mill will produce tailings in excess of the existing capacity of the TMF. After evaluating a number of options, Areva has decided to pursue an expansion of this facility. Areva is developing the Surface Access Borehole Resource Extraction (SABRE) mining method, which uses a high-pressure water jet placed at the bottom of the drill hole to extract ore. Areva has conducted a series of tests with this method and is evaluating its potential for future mining operations. McClean Lake maintains its certification in ISO 14001 standards for environmental management and OHSAS 18001 standards for occupational health

  7. Carbon dioxide nucleation as a novel cleaning method for ultrafiltration membranes

    KAUST Repository

    Al Ghamdi, Mohanned

    2016-12-08

    The use of low-pressure membranes, mainly ultrafiltration (UF), has emerged in the last decade and began to show acceptance as a novel pretreatment process for seawater reverse osmosis (SWRO) desalination. This is mainly due to the superior water quality provided by these membranes, in addition to reduction in chemicals consumption compared to conventional methods. However, membrane fouling remains the main drawback of this technology. Therefore, frequent cleaning of these membranes is required to maintain water flux and its quality. Usually, after a series of backwash using UF permeate chemical cleaning is required under some conditions to fully recover the operating flux. Frequent chemical cleaning will probably decrease the life time of the membrane, increase costs, and will have some effects on the environment. The new cleaning method proposed in this study consists of using a solution saturated with carbon dioxide (CO2) to clean UF membranes. Under the drop in pressure, this solution will become in a supersaturated state and bubbles will start to nucleate on the surface of the membrane and its pores from this solution resulting in the removal of the fouling material deposited on the membrane. Different compositions of fouling solutions including the use of organic compounds such as sodium alginate and colloidal 5 silica with different concentrations were studied using synthetic seawater with different concentrations. This cleaning method was then compared to the backwash using Milli-Q water and showed an improved performance compared to it. An operational modification to this cleaning technique was then investigated which includs a series of sudden pressure drop during the backwash process. This enhanced technique showed an even better performance in cleaning the membrane, especially at severe fouling conditions. In most cases, the membrane permeability was fully recovered even at harsh conditions where conventional backwash failed to maintain a stable

  8. Clean-up criteria for remediation of contaminated soils

    International Nuclear Information System (INIS)

    Nguyen, H.D.; Wilson, J.R.; Sato, Chikashi

    1997-01-01

    'How clean is clean?' is a question commonly raised in the remediation of contaminated soils. To help with the answer, criteria are proposed to serve as guidelines for remedial actions and to define a clean-up level such that the remaining contaminant residuals in the soil will not violate the Drinking Water Standards (DWS). The equations for computing those criteria are developed from the principle of conservation of mass and are functions of the maximum concentration level in the water (MCL) and the sorption coefficient. A multiplier, ranging from 10 to 1000, is also factored into the soil standard equation to reflect the effectiveness of various remediation techniques. Maximum allowable concentration in the soil (MSCL) is presented for several contaminants which are being regulated at the present time. Future modifications are recommended for better estimates of the MSCLs as additional transport mechanisms are incorporated to account for other potentially dominant effects

  9. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  10. Challenges with modifications of the McClean Lake mill to process midwest ore

    International Nuclear Information System (INIS)

    Nguyen, T.T.; Backham, L.

    2010-01-01

    Midwest is a unique uranium deposit with exceptionally high arsenic content. The ore body is located 17 km west of the McClean Lake operation. The McClean Lake mill will be modified to process Midwest ore and handle solid wastes from the Midwest water treatment plant. This paper describes the modifications required of the McClean Lake mill, process challenges associated with treatment of the arsenic, and the possibility of recovering nickel and cobalt as a by-product. It also reviews the complexity in the design of the Midwest water treatment facility which incorporates reverse osmosis technology with conventional physical-chemical water treatment. (author)

  11. Fluorescent Penetrant INSPECTION—CLEANING Study Update

    Science.gov (United States)

    Eisenmann, D.; Brasche, L.

    2009-03-01

    Fluorescent penetrant inspection (FPI) is widely used in the aviation industry and other industries for surface-breaking crack detection. As with all inspection methods, adherence to the process parameters is critical to the successful detection of defects. There is variety of lubricants and surface coatings used in the aviation industry which must be removed prior to FPI. Before the FPI process begins, components are cleaned using a variety of cleaning methods which are selected based on the alloy and the soil types which must be removed. It is also important that the cleaning process not adversely affect the FPI process. From the first three phases of this project it has been found that a hot water rinse can aid in the detection process when using this nondestructive method.

  12. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; E. Huijskens (Elisabeth); de Wit, S.C.J.; Sanders, I.G.J.M.; J.M. van Rosmalen (Joost); E. Kuijper; Voss, A.

    2017-01-01

    textabstractBackground: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested

  13. Condenser performance monitoring and cleaning

    International Nuclear Information System (INIS)

    Walden, J.V.

    1998-01-01

    The main condenser at Ginna Station was retubed from admiralty brass to 316 stainless steel. A condenser performance monitoring spreadsheet was developed using EPRI guidelines after fouling was discovered. PEPSE computer models were used to determine the power loss and confirm the spreadsheet results. Cleaning of the condenser was performed using plastic scrubbers. Condenser performance improved dramatically following the cleaning. PEPSE, condenser spreadsheet performance, and actual observed plant data correlated well together. The fouling mechanism was determined to be a common lake bacteria and fungus growth which was combined with silt. Chlorination of the circulating water system at the allowable limits is keeping the biofouling under control

  14. Effectiveness of various cleaning and disinfectant products on Clostridium difficile spores of PCR ribotypes 010, 014 and 027

    NARCIS (Netherlands)

    Kenters, N.; Huijskens, E.G.; Wit, S.C.J. de; Sanders, I.; Rosmalen, J. van; Kuijper, E.J.; Voss, A.

    2017-01-01

    BACKGROUND: In healthcare facilities, Clostridium difficile infections spread by transmission of bacterial spores. Appropriate sporicidal disinfectants are needed to prevent development of clusters and outbreaks. In this study different cleaning/disinfecting wipes and sprays were tested for their

  15. Chemical cleaning for sludge in steam generator of nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Mengqin; Lu Yucheng; Zhang Binyong; Yu Jinghua

    2002-01-01

    The sludge induced corrosion damage to secondary side of tubes of Steam Generator (SG), effect of chemical cleaning technique on maintenance integrity of tubes of SG NPP and use of chemical cleaning technique in SG NPP have been summarized. The engineering technique of chemical cleaning for removing sludge in secondary side of SG NPP has been studied and qualified by CIAE (China Institute of Atomic Energy). Chemical cleaning engineering technique is introduced (main agent is EDTA, temp. <100 degree C), including chemical cleaning technology for tube plate and full tube nest of secondary side of SG, the monitoring technique of chemical cleaning process (effectiveness and safety), the disposal method of wastage of chemical cleaning, the system of chemical cleaning. The method for preventing sludge deposition in secondary side and the research on advanced water chemistry of secondary loop are introduced

  16. Physical cleaning by bubbly streaming flow in an ultrasound field

    Science.gov (United States)

    Yamashita, Tatsuya; Ando, Keita

    2017-11-01

    Low-intensity ultrasonic cleaning with gas-supersaturated water is a promising method of physical cleaning without erosion; we are able to trigger cavitation bubble nucleation by weak ultrasound under gas supersaturation and thus clean material surfaces by mild bubble dynamics. Here, we perform particle image velocimetry (PIV) measurement of liquid flow and cavitation bubble translation in an ultrasonic cleaning bath driven at 28 kHz and then relate it to cleaning tests using glass slides at which silica particles are attached. The ultrasound pressure amplitude at the cleaning spot is set at 1.4 atm. We select the supersaturation level of dissolved oxygen (DO) as a parameter and control it by oxygen microbubble aeration. It follows from the PIV measurement that the liquid flow is enhanced by the cavitation bubble translation driven by acoustic radiation force; this trend becomes clearer when the bubbles appear more densely as the DO supersaturation increases. In the cleaning tests, the cleaned areas appear as straight streaks. This suggests that physical cleaning is achieved mainly by cavitation bubbles that translate in ultrasound fields.

  17. Clean air in the Anthropocene.

    Science.gov (United States)

    Lelieveld, Jos

    2017-08-24

    In atmospheric chemistry, interactions between air pollution, the biosphere and human health, often through reaction mixtures from both natural and anthropogenic sources, are of growing interest. Massive pollution emissions in the Anthropocene have transformed atmospheric composition to the extent that biogeochemical cycles, air quality and climate have changed globally and partly profoundly. It is estimated that mortality attributable to outdoor air pollution amounts to 4.33 million individuals per year, associated with 123 million years of life lost. Worldwide, air pollution is the major environmental risk factor to human health, and strict air quality standards have the potential to strongly reduce morbidity and mortality. Preserving clean air should be considered a human right, and is fundamental to many sustainable development goals of the United Nations, such as good health, climate action, sustainable cities, clean energy, and protecting life on land and in the water. It would be appropriate to adopt "clean air" as a sustainable development goal.

  18. Researching effective approaches to cleaning in hospitals: protocol of the REACH study, a multi-site stepped-wedge randomised trial.

    Science.gov (United States)

    Hall, Lisa; Farrington, Alison; Mitchell, Brett G; Barnett, Adrian G; Halton, Kate; Allen, Michelle; Page, Katie; Gardner, Anne; Havers, Sally; Bailey, Emily; Dancer, Stephanie J; Riley, Thomas V; Gericke, Christian A; Paterson, David L; Graves, Nicholas

    2016-03-24

    The Researching Effective Approaches to Cleaning in Hospitals (REACH) study will generate evidence about the effectiveness and cost-effectiveness of a novel cleaning initiative that aims to improve the environmental cleanliness of hospitals. The initiative is an environmental cleaning bundle, with five interdependent, evidence-based components (training, technique, product, audit and communication) implemented with environmental services staff to enhance hospital cleaning practices. The REACH study will use a stepped-wedge randomised controlled design to test the study intervention, an environmental cleaning bundle, in 11 Australian hospitals. All trial hospitals will receive the intervention and act as their own control, with analysis undertaken of the change within each hospital based on data collected in the control and intervention periods. Each site will be randomised to one of the 11 intervention timings with staggered commencement dates in 2016 and an intervention period between 20 and 50 weeks. All sites complete the trial at the same time in 2017. The inclusion criteria allow for a purposive sample of both public and private hospitals that have higher-risk patient populations for healthcare-associated infections (HAIs). The primary outcome (objective one) is the monthly number of Staphylococcus aureus bacteraemias (SABs), Clostridium difficile infections (CDIs) and vancomycin resistant enterococci (VRE) infections, per 10,000 bed days. Secondary outcomes for objective one include the thoroughness of hospital cleaning assessed using fluorescent marker technology, the bio-burden of frequent touch surfaces post cleaning and changes in staff knowledge and attitudes about environmental cleaning. A cost-effectiveness analysis will determine the second key outcome (objective two): the incremental cost-effectiveness ratio from implementation of the cleaning bundle. The study uses the integrated Promoting Action on Research Implementation in Health Services (i

  19. Preventing healthcare-associated infections through human factors engineering.

    Science.gov (United States)

    Jacob, Jesse T; Herwaldt, Loreen A; Durso, Francis T

    2018-05-24

    Human factors engineering (HFE) approaches are increasingly being used in healthcare, but have been applied in relatively limited ways to infection prevention and control (IPC). Previous studies have focused on using selected HFE tools, but newer literature supports a system-based HFE approach to IPC. Cross-contamination and the existence of workarounds suggest that healthcare workers need better support to reduce and simplify steps in delivering care. Simplifying workflow can lead to better understanding of why a process fails and allow for improvements to reduce errors and increase efficiency. Hand hygiene can be improved using visual cues and nudges based on room layout. Using personal protective equipment appropriately appears simple, but exists in a complex interaction with workload, behavior, emotion, and environmental variables including product placement. HFE can help prevent the pathogen transmission through improving environmental cleaning and appropriate use of medical devices. Emerging evidence suggests that HFE can be applied in IPC to reduce healthcare-associated infections. HFE and IPC collaboration can help improve many of the basic best practices including use of hand hygiene and personal protective equipment by healthcare workers during patient care.

  20. Probe measurements of hydrogen fluxes during discharge cleaning in JFT-2M

    International Nuclear Information System (INIS)

    Matsuzaki, Y.

    1989-01-01

    Thermal desorption spectroscopy (TDS) has been applied during discharge cleaning in the JFT-2M tokamak to measure hydrogen fluxes. The TDS carbon sample, thickness 0.13 mm, was heated to 1000 0 C by direct current and the temperature distribution of the sample surface measured by infrared thermography. The probe was exposed to three types of plasma: Taylor-type discharge cleaning (TDC), ECR discharge cleaning (ECR-DC), and glow discharge cleaning (GDC). The TDS spectra show peak desorption at around 800 0 C. The hydrogen flux, obtained by integration of the TDS spectrum, decreases exponentially in the radial direction with decay length 7.4 cm and 5.8 cm in TDC and ECR-DC, respectively. The relation between hydrogen fluxes and water vapour production was investigated. In TDC, the amount of water vapour depends more strongly on the electron temperature of the plasma than on the hydrogen flux. In ECR-DC, the production of water vapour increases approximately linearly with the hydrogen-flux. In GDC, hydrogen fluxes were measured by TDS but no water vapour could be detected in the residual gases during the discharge. (orig.)

  1. Aquaporin based biomimetic membrane in forward osmosis: Chemical cleaning resistance and practical operation

    KAUST Repository

    Li, Zhenyu

    2017-07-27

    Aquaporin plays a promising role in fabricating high performance biomimetic forward osmosis (FO) membranes. However, aquaporin as a protein also has a risk of denaturation caused by various chemicals, resulting in a possible decay of membrane performance. The present study tested a novel aquaporin based biomimetic membrane in simulated membrane cleaning processes. The effects of cleaning agents on water flux and salt rejection were evaluated. The membrane showed a good resistance to the chemical agents. The water flux after chemical cleaning showed significant increases, particularly after cleaning with NaOCl and Alconox. Changes in the membrane structure and increased hydrophilicity in the surrounding areas of the aquaporin may be accountable for the increase in water permeability. The membrane shows stable salt rejection up to 99% after all cleaning agents were tested. A 15-day experiment with secondary wastewater effluent as the feed solution and seawater as the draw solution showed a stable flux and high salt rejection. The average rejection of the dissolved organic carbon from wastewater after the 15-day test was 90%. The results demonstrated that the aquaporin based biomimetic FO membrane exhibits chemical resistance for most agents used in membrane cleaning procedures, maintaining a stable flux and high salt rejection.

  2. Aquaporin based biomimetic membrane in forward osmosis: Chemical cleaning resistance and practical operation

    KAUST Repository

    Li, Zhenyu; Valladares Linares, Rodrigo; Bucs, Szilard; Fortunato, Luca; Hé lix-Nielsen, Claus; Vrouwenvelder, Johannes S.; Ghaffour, NorEddine; Leiknes, TorOve; Amy, Gary

    2017-01-01

    Aquaporin plays a promising role in fabricating high performance biomimetic forward osmosis (FO) membranes. However, aquaporin as a protein also has a risk of denaturation caused by various chemicals, resulting in a possible decay of membrane performance. The present study tested a novel aquaporin based biomimetic membrane in simulated membrane cleaning processes. The effects of cleaning agents on water flux and salt rejection were evaluated. The membrane showed a good resistance to the chemical agents. The water flux after chemical cleaning showed significant increases, particularly after cleaning with NaOCl and Alconox. Changes in the membrane structure and increased hydrophilicity in the surrounding areas of the aquaporin may be accountable for the increase in water permeability. The membrane shows stable salt rejection up to 99% after all cleaning agents were tested. A 15-day experiment with secondary wastewater effluent as the feed solution and seawater as the draw solution showed a stable flux and high salt rejection. The average rejection of the dissolved organic carbon from wastewater after the 15-day test was 90%. The results demonstrated that the aquaporin based biomimetic FO membrane exhibits chemical resistance for most agents used in membrane cleaning procedures, maintaining a stable flux and high salt rejection.

  3. Cleaning Robot for Solar Panels in Solar Power Station

    Science.gov (United States)

    Hang, Lu-Bin; Shen, Cheng-Wei; Bian, Huai-Qiang; Wang, Yan

    2016-05-01

    The dust particles on solar panel surface have been a serious problem for the photovoltaic industry, a new monorail-tracked robot used for automatic cleaning of solar panel is presented in this paper. To meet the requirement of comprehensive and stable cleaning of PV array, the monorail-tracked pattern of robot is introduced based on the monorail structure technique. The running and striding mechanism are designed for mobility of robot on the solar panels. According to the carrying capacity and water circulation mechanism, a type of self-cleaning device with filtering system is developed. Combined with the computer software and communications technology, the control system is built in this robot, which can realize the functions of autonomous operation, positioning and monitoring. The application of this developed cleaning robot can actualize the Industrialization of automatic cleaning for PV components and have wide market prospect.

  4. Clean Water State Revolving Fund (CWSRF): Water Conservation

    Science.gov (United States)

    The CWSRF can provide financial assistance for water conservation projects that reduce the demand for POTW capacity through reduced water consumption (i.e., water efficiency), as well as water reuse and precipitation harvesting.

  5. Nonhazardous solvent composition and method for cleaning metal surfaces

    International Nuclear Information System (INIS)

    Googin, J.M.; Simandl, R.F.; Thompson, L.M.

    1993-01-01

    A solvent composition for displacing greasy and oily contaminants as well as water and/or aqueous residue from metallic surfaces, especially surfaces of radioactive materials so that such surfaces can be wiped clean of the displaced contaminants, water and/or aqueous residue. The solvent composition consists essentially of a blend of nonpolar aliphatic hydrocarbon solvent having a minimum flash point of about 140 F and 2 to 25 volume percent of a polar solvent having a flash point sufficiently high so as to provide the solvent composition with a minimum flash point of at least 140 F. The solvent composition is nonhazardous so that when it is used to clean the surfaces of radioactive materials the waste in the form of paper or cloth wipes, lab coats and the like used in the cleaning operation is not considered to be mixed waste composed of a hazardous solvent and a radioactive material

  6. Should you get your heating ducts cleaned?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Canada Mortgage and Housing Corporation conducted research into duct cleaning during which time several houses were tested for hot air furnace duct performance before and after cleaning. Duct cleaning is a major industry which claims that cleaning of ducts will provide you with better indoor air quality, reduce household molds and allergens, get rid of house dust, result in more airflow and better delivery of warm air and reduce energy costs. This report does not substantiate those claims. Researchers found little or no discernible differences in the concentrations of house airborne particles or in duct airflows due to duct cleaning. This is because ducts are metal passages that cannot create dust. Most household dusts come from outdoors that has been tracked in or blows through windows and other openings. While duct cleaning may be justifiable personally, it does not change the quality of the air you breathe, nor will it significantly affect airflow or heating costs. Some filters effectively clean the air in the ducts but they do not create a dust-free environment because of the above-mentioned dust sources. The only time that duct cleaning may make sense is if you have water in your ducts that can result in mold growth, if you are moving into a newly constructed house to remove drywall dust, if your are having trouble with furnace airflow, or if you see an accumulation of debris in the return air ducts. It was emphasized that broadcast spraying of biocides within the duct system should not be performed.

  7. Waste water cleaning in high-performance bioreactors; Abwasserreinigung in Hochleistungsbioreaktoren

    Energy Technology Data Exchange (ETDEWEB)

    Holler, S.; Sternad, W.; Troesch, W. [Fraunhofer-Institut fuer Grenzflaechen- und Bioverfahrenstechnik (IGB), Stuttgart (Germany)

    1999-07-01

    Cleaning of municipal sewage in bioreactors with biomass retention constitutes a modern and sustainable way of cleaning sewage. Contrary to conventional aerated sludge techniques, such systems achieve high productivity at high biomass concentrations. Reactor volume can be kept low, and short retention times are realized. It is shown that a loop reactor in combination with a crossflow microfiltration unit constitutes an appropriate system to meet future demands on sewage cleaning. Such a system can realize a COD turnover of 95 % at retention times of 0.5 hours. Crossflow microfiltration can set the concentration of biomass in the bioreactor to up to 30 grammes of dry substance per litre. (orig.) [German] Die Reinigung kommunaler Abwaesser in Bioreaktoren mit Biomasserueckhaltung stellt ein modernes und nachhaltiges Verfahren zur Abwasserreinigung dar. Im Gegensatz zu konventionellen Belebungsverfahren laesst sich in einem solchen System bei hohen Biomassekonzentrationen eine hohe Produktivitaet erreichen. Das Reaktorvolumen kann gering gehalten werden, und kurze Verweilzeiten koennen realisiert werden. Es wird gezeigt, dass ein Strahlschlaufenreaktor in Kombination mit einer Crossflow-Mikrofiltration ein geeignetes System dargestellt, um die Anforderungen an eine zukuenftige Abwasserreinigung zu gewaehrleisten. In einem solchen System kann ein CSB-Umsatz von 95% bei Verweilzeiten von 0,5 Stunden realisiert werden. Durch Crossflow-Mikrofiltration wird eine Biomassekonzentration bis 30 g TS/l im Bioreaktor eingestellt. (orig.)

  8. Utility view of the source term and air cleaning

    International Nuclear Information System (INIS)

    Littlefield, P.S.

    1985-01-01

    The utility view of the source term and air cleaning is discussed. The source term is made up of: (1) noble gases, which there has been a tendency to ignore in the past because it was thought there was nothing that could be done with them anyway, (2) the halogens, which have been dealt with in Air Cleaning Conferences in the past in terms of charcoal and other systems for removing them, and (3) the solid components of the source term which particulate filters are designed to handle. Air cleaning systems consist of filters, adsorbers, containment sprays, suppression pools in boiling water reactors and ice beds in ice condenser-equipped plants. The feasibility and cost of air cleaning systems are discussed

  9. Ecological effectiveness of oil spill countermeasures: how clean is clean?

    International Nuclear Information System (INIS)

    Baker, J.M.

    1999-01-01

    This paper with 94 references examines background levels of hydrocarbons and the difficulty of defining clean. Processes and timescales for natural cleaning, and factors affecting natural cleaning timescales are considered. Ecological advantages and disadvantages of clean-up methods are highlighted, and five case histories of oil spills are summarised. The relationships between ecological and socio-economic considerations, and the need for a net environmental benefit analysis which takes into account the advantages and disadvantages of clean-up responses and natural clean-up are discussed. A decision tree for evaluating the requirement for shore clean-up is illustrated. (UK)

  10. Society in the north depends on being able to fish in clean waters; Samfunnet i nord er avhengig av aa fiske i et reint hav

    Energy Technology Data Exchange (ETDEWEB)

    Vaage, Roald

    1997-12-31

    This presentation begins by putting the northern seas in a geographic and oceanographic context. This is important for the understanding of the threats and possibilities faced by Norway in the near waters when it comes to keeping these waters clean. Contaminations in Norwegian waters may be carried by the Gulf Stream straight into the Barents Sea to important fish areas west of Spitzbergen. Organic environmental poisons like PCB found in fish from the Barents Sea are mainly air transported. Radioactive contamination of fish from the Barents Sea is decreasing, although it has never been large, but the concentration of environmental poisons and extraneous matter is increasing. It causes concern that considerable concentrations of environmental poisons have been found in polar bears. People in the north of Norway, are not at present worried about clean sea or failing fish resources, but rather about the fact that strong interest groups and others will take an interest in the Barents Sea and adjacent seas. To qualify for an exploration licence for this area, oil companies must document that they will not compromise the purity of Europe`s cleanest seas. It now appears that the greatest threats to the Barents Sea may not come from northbound contaminated flows or from discharge of water from Russian rivers, but from petroleum activities in the area. Probably the petroleum activities will be subject to increasing attention from many sides and the companies will depend on keeping these areas in a clean condition. 12 figs.

  11. Evidence for self-cleaning in gecko setae

    Science.gov (United States)

    Hansen, W. R.; Autumn, K.

    2005-01-01

    A tokay gecko can cling to virtually any surface and support its body mass with a single toe by using the millions of keratinous setae on its toe pads. Each seta branches into hundreds of 200-nm spatulae that make intimate contact with a variety of surface profiles. We showed previously that the combined surface area of billions of spatulae maximizes van der Waals interactions to generate large adhesive and shear forces. Geckos are not known to groom their feet yet retain their stickiness for months between molts. How geckos manage to keep their feet clean while walking about with sticky toes has remained a puzzle until now. Although self-cleaning by water droplets occurs in plant and animal surfaces, no adhesive has been shown to self-clean. In the present study, we demonstrate that gecko setae are a self-cleaning adhesive. Geckos with dirty feet recovered their ability to cling to vertical surfaces after only a few steps. Self-cleaning occurred in arrays of setae isolated from the gecko. Contact mechanical models suggest that self-cleaning occurs by an energetic disequilibrium between the adhesive forces attracting a dirt particle to the substrate and those attracting the same particle to one or more spatulae. We propose that the property of self-cleaning is intrinsic to the setal nanostructure and therefore should be replicable in synthetic adhesive materials in the future. adhesion | contact mechanics | locomotion | reptilia | nanotechnology

  12. Commercial Cleaning Products for Chemical Decontamination: A Scoping Study

    Science.gov (United States)

    2014-05-01

    and may injure human skin without dilution), although this approach is less favoured in a mass casualty decontamination situation than soap and water...commercial cleaning products, full strength K-O-K® liquid bleach (5.25% aqueous solution of NaOCl), dish-washing detergent Cascade® with Extra...Bleach Action Gel, OxiClean® Versatile Stain Remover Powder, and ZEP® Industrial Purple liquid cleaner (proprietary caustic cleaner containing

  13. Self-Cleaning Coatings and Materials for Decontaminating Field-Deployable Land and Water-Based Optical Systems

    Science.gov (United States)

    Ryan, Robert; Underwood, Lauren; Holekamp, Kara; May, George; Spiering, Bruce; Davis, Bruce

    2011-01-01

    This technology exploits the organic decomposition capability and hydrophilic properties of the photocatalytic material titanium dioxide (TiO2), a nontoxic and non-hazardous substance, to address contamination and biofouling issues in field-deployed optical sensor systems. Specifically, this technology incorporates TiO2 coatings and materials applied to, or integrated as a part of, the optical surfaces of sensors and calibration sources, including lenses, windows, and mirrors that are used in remote, unattended, ground-based (land or maritime) optical sensor systems. Current methods used to address contamination or biofouling of these optical surfaces in deployed systems are costly, toxic, labor intensive, and non-preventative. By implementing this novel technology, many of these negative aspects can be reduced. The functionality of this innovative self-cleaning solution to address the problem of contamination or biofouling depends on the availability of a sufficient light source with the appropriate spectral properties, which can be attained naturally via sunlight or supplemented using artificial illumination such as UV LEDs (light emitting diodes). In land-based or above-water systems, the TiO2 optical surface is exposed to sunlight, which catalyzes the photocatalytic reaction, facilitating both the decomposition of inorganic and organic compounds, and the activation of superhydrophilic properties. Since underwater optical surfaces are submerged and have limited sunlight exposure, supplementary UV light sources would be required to activate the TiO2 on these optical surfaces. Nighttime operation of land-based or above-water systems would require this addition as well. For most superhydrophilic self-cleaning purposes, a rainwater wash will suffice; however, for some applications an attached rainwater collector/ dispenser or other fresh water dispensing system may be required to wash the optical surface and initiate the removal of contaminates. Deployment of this

  14. Empowering village doctors and enhancing rural healthcare using cloud computing in a rural area of mainland China.

    Science.gov (United States)

    Lin, Che-Wei; Abdul, Shabbir Syed; Clinciu, Daniel L; Scholl, Jeremiah; Jin, Xiangdong; Lu, Haifei; Chen, Steve S; Iqbal, Usman; Heineck, Maxwell J; Li, Yu-Chuan

    2014-02-01

    China's healthcare system often struggles to meet the needs of its 900 million people living in rural areas due to major challenges in preventive medicine and management of chronic diseases. Here we address some of these challenges by equipping village doctors (ViDs) with Health Information Technology and developing an electronic health record (EHR) system which collects individual patient information electronically to aid with implementation of chronic disease management programs. An EHR system based on a cloud-computing architecture was developed and deployed in Xilingol county of Inner Mongolia using various computing resources (hardware and software) to deliver services over the health network using Internet when available. The system supports the work at all levels of the healthcare system, including the work of ViDs in rural areas. An analysis done on 291,087 EHRs created from November 2008 to June 2011 evaluated the impact the EHR system has on preventive medicine and chronic disease management programs in rural China. From 2008 to 2011 health records were created for 291,087 (26.25%) from 1,108,951 total Xilingol residents with 10,240 cases of hypertension and 1152 cases of diabetes diagnosed and registered. Furthermore, 2945 hypertensive and 305 diabetic patients enrolled in follow-up. Implementing the EHR system revealed a high rate of cholecystectomies leading to investigations and findings of drinking water contaminated with metals. Measures were taken to inform the population and clean drinking water was supplied. The cloud-based EHR approach improved the care provision for ViDs in rural China and increased the efficiency of the healthcare system to monitor the health status of the population and to manage preventive care efforts. It also helped discover contaminated water in one of the project areas revealing further benefits if the system is expanded and improved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Chemical cleaning - essential for optimal steam generator asset management

    International Nuclear Information System (INIS)

    Ammann, Franz

    2009-01-01

    Accumulation of deposits in Steam Generator is intrinsic during the operation of Pressurized Water Reactors. Such depositions lead to reduction of thermal performance, loss of component integrity and, in some cases, to power restrictions. Accordingly, removal of such deposits is an essential part of the asset management program of Steam Generators. Every plant has specific conditions, history and constraints which must be considered when planning and performing a chemical cleaning. Typical points are: -Constitution of the deposits or sludge - Sludge load - Sludge distribution in the steam generator - Existing or expected corrosion problems - Amount and tendency of fouling for waste treatment The strategy for chemical cleaning is developed from these points. The range of chemical cleaning treatments starts with very soft cleanings which can remove approximately 100kg per steam generator and ends with full scale, i.e., hard, cleanings which can remove several thousand kilograms of deposits from a steam generator. Dependent upon the desired goal for the operating plant and the steam generator material condition, the correct cleaning method can be selected. This requires flexible cleaning methods that can be adapted to the individual needs of a plant. Such customizing of chemical cleaning methods is a crucial factor for an optimized asset management program of steam generators in a nuclear power plant

  16. Textile Dry Cleaning Using Carbon Dioxide : Process, Apparatus and Mechanical Action

    NARCIS (Netherlands)

    Sutanto, S.

    2014-01-01

    Fabrics that are sensitive to water, may wrinkle or shrink when washed in regular washing machines and are usually cleaned by professional dry cleaners. Dry cleaning is a process of removing soils from substrate, in this case textile, using a non-aqueous solvent. The most common solvent in

  17. What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Vincenzo Russotto

    2017-01-01

    Full Text Available Intensive care unit- (ICU- acquired infections are a major health problem worldwide. Inanimate surfaces and equipment contamination may play a role in cross-transmission of pathogens and subsequent patient colonization or infection. Bacteria contaminate inanimate surfaces and equipment of the patient zone and healthcare area, generating a reservoir of potential pathogens, including multidrug resistant species. Traditional terminal cleaning methods have limitations. Indeed patients who receive a bed from prior patient carrying bacteria are exposed to an increased risk (odds ratio 2.13, 95% confidence intervals 1.62–2.81 of being colonized and potentially infected by the same bacterial species of the previous patient. Biofilm formation, even on dry surfaces, may play a role in reducing the efficacy of terminal cleaning procedures since it enables bacteria to survive in the environment for a long period and provides increased resistance to commonly used disinfectants. No-touch methods (e.g., UV-light, hydrogen peroxide vapour are under investigation and further studies with patient-centred outcomes are needed, before considering them the standard of terminal cleaning in ICUs. Healthcare workers should be aware of the role of environmental contamination in the ICU and consider it in the broader perspective of infection control measures and stewardship initiatives.

  18. What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit.

    Science.gov (United States)

    Russotto, Vincenzo; Cortegiani, Andrea; Fasciana, Teresa; Iozzo, Pasquale; Raineri, Santi Maurizio; Gregoretti, Cesare; Giammanco, Anna; Giarratano, Antonino

    2017-01-01

    Intensive care unit- (ICU-) acquired infections are a major health problem worldwide. Inanimate surfaces and equipment contamination may play a role in cross-transmission of pathogens and subsequent patient colonization or infection. Bacteria contaminate inanimate surfaces and equipment of the patient zone and healthcare area, generating a reservoir of potential pathogens, including multidrug resistant species. Traditional terminal cleaning methods have limitations. Indeed patients who receive a bed from prior patient carrying bacteria are exposed to an increased risk (odds ratio 2.13, 95% confidence intervals 1.62-2.81) of being colonized and potentially infected by the same bacterial species of the previous patient. Biofilm formation, even on dry surfaces, may play a role in reducing the efficacy of terminal cleaning procedures since it enables bacteria to survive in the environment for a long period and provides increased resistance to commonly used disinfectants. No-touch methods (e.g., UV-light, hydrogen peroxide vapour) are under investigation and further studies with patient-centred outcomes are needed, before considering them the standard of terminal cleaning in ICUs. Healthcare workers should be aware of the role of environmental contamination in the ICU and consider it in the broader perspective of infection control measures and stewardship initiatives.

  19. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    Science.gov (United States)

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  20. Interactive Visualization of Healthcare Data Using Tableau.

    Science.gov (United States)

    Ko, Inseok; Chang, Hyejung

    2017-10-01

    Big data analysis is receiving increasing attention in many industries, including healthcare. Visualization plays an important role not only in intuitively showing the results of data analysis but also in the whole process of collecting, cleaning, analyzing, and sharing data. This paper presents a procedure for the interactive visualization and analysis of healthcare data using Tableau as a business intelligence tool. Starting with installation of the Tableau Desktop Personal version 10.3, this paper describes the process of understanding and visualizing healthcare data using an example. The example data of colon cancer patients were obtained from health insurance claims in years 2012 and 2013, provided by the Health Insurance Review and Assessment Service. To explore the visualization of healthcare data using Tableau for beginners, this paper describes the creation of a simple view for the average length of stay of colon cancer patients. Since Tableau provides various visualizations and customizations, the level of analysis can be increased with small multiples, view filtering, mark cards, and Tableau charts. Tableau is a software that can help users explore and understand their data by creating interactive visualizations. The software has the advantages that it can be used in conjunction with almost any database, and it is easy to use by dragging and dropping to create an interactive visualization expressing the desired format.

  1. Ion filter for high temperature cleaning

    International Nuclear Information System (INIS)

    Kutomi, Yasuhiro; Nakamori, Masaharu.

    1994-01-01

    A porous ceramic pipe mainly comprising alumina is used as a base pipe, and then crud and radioactive ion adsorbing materials in high temperature and high pressure water mainly comprising a FeTiO 3 compound are flame-coated on the outer surface thereof to a film thickness of about 100 to 300μ m as an aimed value by an acetylene flame-coating method. The flame-coated FeTiO 3 layer is also porous, so that high temperature and high pressure water to be cleaned can pass through from the inside to the outside of the pipe. Cruds can be removed and radioactive ions can be adsorbed during passage. Since all the operations can be conducted at high temperature and high pressure state, cooling is no more necessary for the high temperature and high pressure water to be cleaned, heat efficiency of the plant can be improved and a cooling facility can be saved. Further, since the flame-coating of FeTiO 3 to the porous ceramic pipe can be conducted extremely easily compared with production of a sintering product, cost for the production of filter elements can be saved remarkably. (T.M.)

  2. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  3. ODS - modified TiO2 nanoparticles for the preparation of self-cleaning superhydrophobic coating

    Science.gov (United States)

    Kokare, Ashvini M.; Sutar, Rajaram S.; Deshmukh, S. G.; Xing, Ruimin; Liu, Shanhu; Latthe, Sanjay S.

    2018-05-01

    Rolling water drops takes off dust particles from lotus leaf showing self-cleaning performance. Self-cleaning effect has great importance in industry as well as in daily life. The present paper describes the preparation of self-cleaning superhydrophobic coating through simple and low cost dip coating technique. The prepared superhydrophobic surface enact as lotus leaf. Firstly TiO2 nanoparticles were dispersed in ethanol and different concentration of octadecyltrichlorosilane (ODS) was added in TiO2 dispersion. The effect of number of deposition layer on the wettability of the coating was studied. The coating prepared from five deposition layers showed contact angle higher than 150° and sliding angle less than 10°. The superhydrophobicity increases with increasing concentration of ODS. The hierarchical rough morphology which is preferable for superhydrophobicity was obtained. The prepared coatings were stable against water jet impact and showed repellent towards colored and muddy water. Such superhydrophobic coating can find enormous scope in self-cleaning application.

  4. CLEAN RIVER PROGRAM AT KALIGARANG CENTRAL JAVA PROVINCE

    Directory of Open Access Journals (Sweden)

    Harihanto Harihanto

    2006-11-01

    Full Text Available Kaligarang River that located n Central Java Province represents one of the rivers in Indonesia which water quality was proved very bad. Since 1989 Clean River Program has been executed in this river. Nevertheless, untul 1998 there have not yet independent evaluation towards this program. To Know wether of this program successful a survey has been conducted from November 1998 to November 1999. The success of this program investigated by: (1 reducing of pollutant loads, (2 target of pollution loads that reached, and (3 improving of river water quality. It was foujd that this program has been successfully reducing pollutant loads of waste of all factories as target froups. Nevertheless, the quality of water of Kaligarang River was still relatively bad. This condition porbably was cause by domestic waste partivularly from hospital, hotel, restaurant dan small factories that was not included as tartet group in this program. Thus it was conclude at the implementation of the Clean River Program in Kaligarang has not been succesful to im[rove water quality of this river.

  5. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    Science.gov (United States)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-09-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  6. Preparation and characterization of underwater superoleophobic chitosan/poly(vinyl alcohol) coatings for self-cleaning and oil/water separation

    International Nuclear Information System (INIS)

    Wang, Qian; Fu, Youjia; Yan, Xiaoxia; Chang, Yanjiao; Ren, Lili; Zhou, Jiang

    2017-01-01

    Highlights: • Underwater superoleophobic CS/PVA coatings were prepared using a facile method. • Immersion in NaOH solution was crucial to enhance roughness of the coating surface. • Effects of coating composition on wettability of coating surface were investigated. • The CS/PVA coatings possess self-cleaning property. • The CS/PVA coatings can be used for oil/water separation with high efficiency. - Abstract: In this paper, chitosan (CS)/poly(vinyl alcohol) (PVA) coatings cross-linked with glutaraldehyde (GA) were prepared. Effects of the coating composition and NaOH solution treatment on surface morphology and topography were investigated by scanning electron microscope and atomic force microscope. It was found that the process of immersing the CS/PVA coatings into NaOH solution was crucial to enhance rough structure on the coating surface. The rough surface structure and the hydrophilic groups of CS and PVA made the CS/PVA coatings possess underwater superoleophobicity and low adhesion to oil. Oil contact angle of the prepared CS/PVA coatings was up to 161° and slide angle was only 3°. Moreover, the CS/PVA coatings showed stable superoleophobicity in high salt, strong acidic, and alkaline environments as well as underwater self-cleaning property and excellent transparency. The CS/PVA coatings could be used for gravity driven oil/water separation with high efficiency.

  7. Preparation and characterization of underwater superoleophobic chitosan/poly(vinyl alcohol) coatings for self-cleaning and oil/water separation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qian; Fu, Youjia; Yan, Xiaoxia; Chang, Yanjiao; Ren, Lili; Zhou, Jiang

    2017-08-01

    Highlights: • Underwater superoleophobic CS/PVA coatings were prepared using a facile method. • Immersion in NaOH solution was crucial to enhance roughness of the coating surface. • Effects of coating composition on wettability of coating surface were investigated. • The CS/PVA coatings possess self-cleaning property. • The CS/PVA coatings can be used for oil/water separation with high efficiency. - Abstract: In this paper, chitosan (CS)/poly(vinyl alcohol) (PVA) coatings cross-linked with glutaraldehyde (GA) were prepared. Effects of the coating composition and NaOH solution treatment on surface morphology and topography were investigated by scanning electron microscope and atomic force microscope. It was found that the process of immersing the CS/PVA coatings into NaOH solution was crucial to enhance rough structure on the coating surface. The rough surface structure and the hydrophilic groups of CS and PVA made the CS/PVA coatings possess underwater superoleophobicity and low adhesion to oil. Oil contact angle of the prepared CS/PVA coatings was up to 161° and slide angle was only 3°. Moreover, the CS/PVA coatings showed stable superoleophobicity in high salt, strong acidic, and alkaline environments as well as underwater self-cleaning property and excellent transparency. The CS/PVA coatings could be used for gravity driven oil/water separation with high efficiency.

  8. Dynamic change of surface microbiota with different environmental cleaning methods between two wards in a hospital.

    Science.gov (United States)

    Chen, Chang-Hua; Tu, Chi-Chao; Kuo, Han-Yueh; Zeng, Rong-Fong; Yu, Cheng-Sheng; Lu, Henry Horng-Shing; Liou, Ming-Li

    2017-01-01

    Terminal disinfection and daily cleaning have been performed in hospitals in Taiwan for many years to reduce the risks of healthcare-associated infections. However, the effectiveness of these cleaning approaches and dynamic changes of surface microbiota upon cleaning remain unclear. Here, we report the surface changes of bacterial communities with terminal disinfection and daily cleaning in a medical intensive care unit (MICU) and only terminal disinfection in a respiratory care center (RCC) using 16s ribosomal RNA (rRNA) metagenomics. A total of 36 samples, including 9 samples per sampling time, from each ward were analysed. The clinical isolates were recorded during the sampling time. A large amount of microbial diversity was detected, and human skin microbiota (HSM) was predominant in both wards. In addition, the colonization rate of the HSM in the MICU was higher than that in the RCC, especially for Moraxellaceae. A higher alpha-diversity (p = 0.005519) and a lower UniFrac distance was shown in the RCC due to the lack of daily cleaning. Moreover, a significantly higher abundance among Acinetobacter sp., Streptococcus sp. and Pseudomonas sp. was shown in the RCC compared to the MICU using the paired t test. We concluded that cleaning changes might contribute to the difference in diversity between two wards.

  9. Life cycle assessment ultra-clean micronized coal-water-oil fuel preparation and its usage in diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Fu, X.; Wang, Z.; Novelli, G.; Benedetti, B. [China University of Mining and Technology, Beijing (China)

    2005-08-15

    The study described the preparation of ultra-clean micronized coal-water-oil fuel (UCMWOF) and its usage in diesel engine. The production and usage of UCMCWOF and diesel oil, on a Life Cycle Assessment (LCA) basis, were evaluated. A comparison between the two systems shows that beside reducing of photochemical ozone creation potential and rest indicators in UCMCWOF increase. This predicates that the system of UCMCWOF is characterized by high global environmental impact, but its local impacts are lower if compared with the use of diesel and traditional coal. 3 refs., 3 figs., 3 tabs.

  10. Advanced waste water cleaning with the aid of an algae biofilm; Weitergehende Abwasserreinigung mit Hilfe eines Algenbiofilms

    Energy Technology Data Exchange (ETDEWEB)

    Schumacher, G.; Patzold, V.; Ike, A.; Sekoulov, I. [Technische Univ. Hamburg-Harburg, Hamburg (Germany). Arbeitsbereich Abwasserwirtschaft

    1999-07-01

    These first investigations have led to results indicating that advanced waste water cleaning with the aid of algae biofilm as a downstream process stage is feasible. The concentration of phosphorus in waste water could be reduced to less than 1 mg per litre. Ammonium, which is toxic to fish, was nitrified, and the overall nitrogen concentration could be cut down. The concentration of bacteria was reduced by means of a close-to-nature process to less than the limiting values set by the European Union directive governing the quality of bathing waters. (orig.) [German] Die Ergebnisse dieser ersten Untersuchungen zeigen, dass eine weitergehende Abwasserreinigung mit Hilfe eines Algenbiofilms als nachgeschaltete Verfahrensstufe moeglich ist. Die Phosphorkonzentration im Abwasser konnte auf unter 1 mg/l reduziert werden. Fischgiftiges Ammonium wurde nitrifiziert und die Gesamtstickstoffkonzentration konnte gesenkt werden. Die Bakterienkonzentration konnte mit Hilfe eines naturnahen Verfahrens bis unter die Grenzwerte der EU-Richtlinie ueber die Qualitaet der Badegewaesser reduziert werden. (orig.)

  11. Controlling the cost of clean air - A new clean coal technology

    International Nuclear Information System (INIS)

    Kindig, J.K.; Godfrey, R.L.

    1991-01-01

    This article presents the authors' alternative to expensive coal combustion products clean-up by cleaning the coal, removing the sulfur, before combustion. Topics discussed include sulfur in coal and the coal cleaning process, the nature of a new coal cleaning technology, the impact on Clean Air Act compliance, and the economics of the new technology

  12. Mechanical cleaning of oil spills in seawater using circular conduits

    Energy Technology Data Exchange (ETDEWEB)

    Shedid, S.; Abou Kassem, J.; Zekri, A. [United Arab Emirates Univ., Al Ain City (United Arab Emirates). Dept. of Chemical and Petroleum Engineering

    2005-10-15

    Treatment of the crude oil pollution in seawater has attracted global attention during the last two decades. This study was undertaken using circular conduits as a mechanical means to clean oil spills in seawater under different conditions of temperature, oil gravity, shaking frequency, conduit diameter, and initial thickness of oil layer. An experimental model was designed and built to achieve the study. It consists of shaking water bath (to represent sea waves) fitted with temperature controller and glass tubes of different inside diameters of 0.3 cm, 0.5 cm, and 0.7 cm. Three crude oils of different oil gravity of 35{sup o}API, 38{sup o}API, and 47{sup o}API were investigated under different shaking frequencies of 20, 40, and 60 stroke/minute with different tube diameters. The results proved that application of mechanical cleaning of oil spills using circular conduits is a practical technique. The cleaning of black oil spills is more efficient than one of volatile oil. Furthermore, the results indicated that the increase of shaking frequency and/or water temperature provide(s) faster cleaning of oil spills while temperature increase recovers the maximum oil. (Author)

  13. HYDRAULIC ELEVATOR INSTALLATION ESTIMATION FOR THE WATER SOURCE WELL SAND-PACK CLEANING UP

    Directory of Open Access Journals (Sweden)

    V. V. Ivashechkin

    2016-01-01

    Full Text Available The article offers design of a hydraulic elevator installation for cleaning up water-source wells of sand packs. It considerers the installation hydraulic circuit according to which the normal pump feeds the high-level tank water into the borehole through two parallel water lines. The water-jet line with washing nozzle for destroying the sand-pack and the supply pipe-line coupled with the operational nozzle of the hydraulic elevator containing the inlet and the supply pipelines for respectively intaking the hydromixture and removing it from the well. The paper adduces equations for fluid motion in the supply and the water-jet pipelines and offers expressions for evaluating the required heads in them. For determining water flow in the supply and the water-jet pipe lines the author proposes to employ graphical approach allowing finding the regime point in Q–H chart by means of building characteristics of the pump and the pipe-lines. For calculating the useful vertical head, supply and dimensions of the hydraulic elevator the article employs the equation of motion quantity with consistency admission of the motion quantity before and after mixing the flows in the hydraulic elevator. The suggested correlations for evaluating the hydraulic elevator efficiency determine the sand pack removal duration as function of its sizes and the ejected fluid flow rate. A hydraulic-elevator installation parameters estimation example illustrates removing a sand pack from a water-source borehole of 41 m deep and 150 mm diameter bored in the village of Uzla of Myadelsk region, of Minsk oblast. The working efficiency of a manufactured and laboratory tested engineering prototype of the hydraulic elevator installation was acknowledged in actual tests at the indicated borehole site. With application of graphical approach, the suggested for the hydraulic elevator installation parameters calculation procedure allows selecting, with given depth and the borehole diameter

  14. Cleaning fluid emulsions

    Energy Technology Data Exchange (ETDEWEB)

    Prikryl, J; Kotyza, R; Krulikovsky, J; Mjartan, V; Valisova, I

    1981-09-15

    Composition of cleaning fluid emulsion are presented for drilling small diameter wells in clay soils, at high drill bit rotation velocity. The emulsions have lubricating properties and the abilty to improve stability of the drilled soil. The given fluids have a high fatty acid content with 12-24 carbon atoms in a single molecule, with a predominance of resinous acids 1-5% in mass, and having been emulsified in water or clay suspension without additives, or in a clay suspension with high-molecular polymer additives (glycobate cellulose compounds and/or polysaccharides, and/or their derivatives) in an amount of 0.1-3% per mass; thinning agents - huminite or lignite compounds in the amount of 0.01 to 0.5% in mass; weighting material - barite or lime 0.01 to 50% per mass; medium stabilizers - organic poly-electrolyte with polyacrylate in the amount of 0.05 to 2% in mass, or alkaline chloride/alkaline-ground metals 1-10% per mass. A cleaning emulsion fluid was prepared in the laboratory according to the given method. Add 3 kg tall oil to a solution of 1 kg K/sub 2/CO/sub 3/ per 100 l of water. Dynamic viscosity was equal to 1.4 x 10-/sup 3/ Pa/s. When drilling in compacted clay soils, when the emulsions require improved stability, it is necessary to add the maximum amount of tall oil whose molecules are absorbed by the clay soil and increase its durability.

  15. Study of bacterial flora associated with mobile phones of healthcare workers and non-healthcare workers.

    Science.gov (United States)

    Morubagal, Raghavendra Rao; Shivappa, Sowmya Govindanahalli; Mahale, Rashmi Padmanabha; Neelambike, Sumana Mhadevaiah

    2017-06-01

    Despite improvements in modern diagnosis and therapies, hospital acquired infections remain a leading problem of global health systems. Healthcare workers mobile phones is a reservoir for potential pathogens. Despite the high possibility of being contaminated, mobile phones are rarely clean and are often touched during or after examination of patients and handling of specimens without proper hand washing. The main objective of the present study was to isolate, identify different types of bacteria and their antibiotic sensitivity from mobile phones of healthcare workers and non-health-care workers. Samples were collected aseptically by rolling over the exposed surfaces of the mobile phones inoculated on the agar plates and incubated aerobically. After incubation, plates were examined for growth. Bacteria were identified and antibiotic sensitivity was tested as per standard microbiological procedures. In this study a total of 175 samples were examined, out of which 125 samples were from healthcare workers (HCWs), 50 samples were from non-healthcare workers (non-HCWs). Among the mobile phones of HCW's from ICUs, Acinetobacter baumannii (36.84%) was the predominant organism isolated followed by methicillin resistant Staphylococcus aureus (MRSA) (21.05%). Predominant organism isolated from HCW's in operation theater theater was MRSA (46.66%). Out of 50 worker's non-HCWs mobile phones samples cultured, 23 (46.00%) samples yielded growth of six different types of bacteria. Our study reveals that there is definite colonization of bacteria on mobile phones of the HCWs. It is not only capable of transferring message but also disease-producing microbes. In order to reduce incidence of nosocomial infections, there should be implementation of hand washing practices and regulations around the use of mobile telephones in hospital settings.

  16. Use of a fluorescent chemical as a quality indicator for a hospital cleaning program.

    Science.gov (United States)

    Blue, Jennifer; O'Neill, Cindy; Speziale, Paul; Revill, Jeff; Ramage, Lee; Ballantyne, Lisa

    2008-01-01

    Hamilton Health Sciences is a large teaching hospital with over 1,000 beds and consists of three acute care sites, one Regional Cancer Center and two Rehabilitation/Chronic Care facilities. An environmental cleaning pilot project was initiated at the acute care Henderson site, following an outbreak of vancomycin-resistant Enterococcus (VRE). Healthcare-associated infections (HAI) due to antibiotic-resistant organisms are increasing in Southern Ontario. Environmental cleaning plays a key role in eradicating resistant organisms that live in hospital environments, thereby helping to reduce HAIs. The environmental cleaning practices on the Orthopaedic Unit were identified as a contributing factor to the VRE outbreak after visual assessments were completed using a Brevis GlitterBug product, a chemical that fluoresces under an ultraviolet (UV) lamp. These findings led to a hospital-wide cleaning improvement initiative on all units except critical care areas. The GlitterBug potion was employed by Infection Control and Customer Support Services (CSS) as a tool to evaluate the daily cleaning of patient washrooms as well as discharge cleaning of contact precaution isolation rooms. Over a four-week period, the GlitterBug potion was applied to seven frequently touched standard targets in randomly selected patient bathrooms on each unit and 14 frequently touched targets prior to cleaning in the rooms used for isolation. The targets were then evaluated using the UV lamp to detect objects that were not cleaned and the results were recorded on a standardized form. The rate of targets cleaned versus the targets missed was calculated. The overall rate for daily cleaning of bathrooms and cleaning of isolation rooms was poor with only 23% of the targets cleaned. Based on these findings, several interventions were implemented. This resulted in a significant improvement in cleaning practices during the pilot project. Greater than 80% of the targets were cleaned compared to the baseline

  17. Bio-Inspired Polymer Membrane Surface Cleaning

    Directory of Open Access Journals (Sweden)

    Agnes Schulze

    2017-03-01

    Full Text Available To generate polyethersulfone membranes with a biocatalytically active surface, pancreatin was covalently immobilized. Pancreatin is a mixture of digestive enzymes such as protease, lipase, and amylase. The resulting membranes exhibit self-cleaning properties after “switching on” the respective enzyme by adjusting pH and temperature. Thus, the membrane surface can actively degrade a fouling layer on its surface and regain initial permeability. Fouling tests with solutions of protein, oil, and mixtures of both, were performed, and the membrane’s ability to self-clean the fouled surface was characterized. Membrane characterization was conducted by investigation of the immobilized enzyme concentration, enzyme activity, water permeation flux, fouling tests, porosimetry, X-ray photoelectron spectroscopy, and scanning electron microscopy.

  18. Critical cleaning agents for Di-2-ethylhexyl sebacate.

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, Mya; Archuleta, Kim M.

    2013-08-01

    It is required that Di-2-ethylhexyl Sebacate oil, also commonly known as Dioctyl Sebacate oil, be thoroughly removed from certain metals, in this case stainless steel parts with narrow, enclosed spaces. Dioctyl Sebacate oil is a synthetic oil with a low compressibility. As such, it is ideally used for high pressure calibrations. The current method to remove the Dioctyl Sebacate from stainless steel parts with narrow, enclosed spaces is a labor-intensive, multi-step process, including a detergent clean, a deionized (DI) water rinse, and several solvent rinses, to achieve a nonvolatile residue of 0.04 mg per 50 mL rinse effluent. This study was undertaken to determine a superior detergent/solvent cleaning method for the oil to reduce cleaning time and/or the amount of detergent/solvent used. It was determined that while some detergent clean the oil off the metal better than the current procedure, using only solvents obtained the best result. In addition, it can be inferred, based on elevated temperature test results, that raising the temperature of the oil-contaminated stainless steel parts to approximately 50ÀC will provide for improved cleaning efficacy.

  19. Discharge cleaning on TFTR after boronization

    International Nuclear Information System (INIS)

    Mueller, D.; Dylla, H.F.; LaMarche, P.H.; Bell, M.G.; Blanchard, W.; Bush, C.E.; Gentile, C.; Hawryluk, R.J.; HIll, K.W.; Janos, A.C.; Jobes, F.C; Owens, D.K.; Pearson, G.; Schivell, J.; Ulrickson, M.A.; Vannoy, C.; Wong, K.L.

    1991-05-01

    At the beginning of the 1990 TFTR experimental run, after replacement of POCO-AXF-5Q graphite tiles on the midplane of the bumper limiter by carbon fiber composite (CFC) tiles and prior to any Pulse Discharge Cleaning (PDC), boronization was performed. Boronization is the deposition of a layer of boron and carbon on the vacuum vessel inner surface by a glow discharge in a diborane, methane and helium mixture. The amount of discharge cleaning required after boronization was substantially reduced compared to that which was needed after previous openings when boronization was not done. Previously, after a major shutdown, about 10 5 low current (∼20 kA) Taylor Discharge Cleaning (TDC) pulses were required before high current (∼400 kA) aggressive Pulse Discharge Cleaning (PDC) pulses could be performed successfully. Aggressive PDC is used to heat the limiters from the vessel bakeout temperature of 150 degrees C to 250 degrees C for a period of several hours. Heating the limiters is important to increase the rate at which water is removed from the carbon limiter tiles. After boronization, the number of required TDC pulses was reduced to <5000. The number of aggressive PDC pulses required was approximately unchanged. 14 refs., 1 tab

  20. NOVEL GAS CLEANING/CONDITIONING FOR INTEGRATED GASIFICATION COMBINED CYCLE

    Energy Technology Data Exchange (ETDEWEB)

    Dennis A. Horazak; Richard A. Newby; Eugene E. Smeltzer; Rachid B. Slimane; P. Vann Bush; James L. Aderhold Jr; Bruce G. Bryan

    2005-12-01

    Development efforts have been underway for decades to replace dry-gas cleaning technology with humid-gas cleaning technology that would maintain the water vapor content in the raw gas by conducting cleaning at sufficiently high temperature to avoid water vapor condensation and would thus significantly simplify the plant and improve its thermal efficiency. Siemens Power Generation, Inc. conducted a program with the Gas Technology Institute (GTI) to develop a Novel Gas Cleaning process that uses a new type of gas-sorbent contactor, the ''filter-reactor''. The Filter-Reactor Novel Gas Cleaning process described and evaluated here is in its early stages of development and this evaluation is classified as conceptual. The commercial evaluations have been coupled with integrated Process Development Unit testing performed at a GTI coal gasifier test facility to demonstrate, at sub-scale the process performance capabilities. The commercial evaluations and Process Development Unit test results are presented in Volumes 1 and 2 of this report, respectively. Two gas cleaning applications with significantly differing gas cleaning requirements were considered in the evaluation: IGCC power generation, and Methanol Synthesis with electric power co-production. For the IGCC power generation application, two sets of gas cleaning requirements were applied, one representing the most stringent ''current'' gas cleaning requirements, and a second set representing possible, very stringent ''future'' gas cleaning requirements. Current gas cleaning requirements were used for Methanol Synthesis in the evaluation because these cleaning requirements represent the most stringent of cleaning requirements and the most challenging for the Filter-Reactor Novel Gas Cleaning process. The scope of the evaluation for each application was: (1) Select the configuration for the Filter-Reactor Novel Gas Cleaning Process, the arrangement of the

  1. Successful cleaning concept for Germany's biggest reverse osmosis plant; Ein erfolgreiches Reinigungskonzept fuer die groesste Umkehrosmoseanlage Deutschlands

    Energy Technology Data Exchange (ETDEWEB)

    Kempen, Hermann [Kurita Europe GmbH, Viersen (Germany); Zierau, Ronald [Zellstoff-Stendal GmbH, Arneburg (Germany)

    2012-07-01

    During the last years, new developments for membrane material and also for treatment chemicals have resulted in higher efficiency and reliability of reverse osmosis (RO) plants. Nevertheless, especially RO plants receiving raw water from surface waters with open intake or from waste water streams are facing problems with fouling on membranes during operation. In such cases, the efficient cleaning of membranes is mandatory to ensure long-term supply of permeate in high quality and sufficient quantity. New cleaning concepts with proprietary cleaning products are gaining in importance. The successful application of such a cleaning concept at Germany's biggest RO plant is described in this paper. (orig.)

  2. July 2011 Memorandum: Improving EPA Review of Appalachian Surface Coal Mining Operations Under the Clean Water Act, National Environmental Policy Act, and the Environmental Justice Executive Order

    Science.gov (United States)

    Memorandum: Improving EPA Review of Appalachian Surface Coal Mining Operations Under the Clean Water Act, National Environmental Policy Act, and the Environmental Justice Executive Order, July 21, 2011

  3. Significant reduction in vancomycin-resistant enterococcus colonization and bacteraemia after introduction of a bleach-based cleaning-disinfection programme.

    Science.gov (United States)

    Grabsch, E A; Mahony, A A; Cameron, D R M; Martin, R D; Heland, M; Davey, P; Petty, M; Xie, S; Grayson, M L

    2012-12-01

    Vancomycin-resistant enterococcus (VRE) colonization and infection have increased at our hospital, despite adherence to standard VRE control guidelines. We implemented a multi-modal, hospital-wide improvement programme including a bleach-based cleaning-disinfection programme ('Bleach-Clean'). VRE colonization, infection and environmental contamination were compared pre and post implementation. The programme included a new product (sodium hypochlorite 1000 ppm + detergent), standardized cleaning-disinfection practices, employment of cleaning supervisors, and modified protocols to rely on alcohol-based hand hygiene and sleeveless aprons instead of long-sleeved gowns and gloves. VRE was isolated using chromogenic agar and/or routine laboratory methods. Outcomes were assessed during the 6 months pre and 12 months post implementation, including proportions (per 100 patients screened) of VRE colonization in high-risk wards (HRWs: intensive care, liver transplant, renal, haematology/oncology); proportions of environmental contamination; and episodes of VRE bacteraemia throughout the entire hospital. Significant reductions in newly recognized VRE colonizations (208/1948 patients screened vs 324/4035, a 24.8% reduction, P = 0.001) and environmental contamination (66.4% reduction, P = 0.012) were observed, but the proportion of patients colonized on admission was stable. The total burden of inpatients with VRE in the HRWs also declined (median percentage of colonized inpatients per week, 19.4% vs 17.3%, P = 0.016). Hospital-wide VRE bacteraemia declined from 14/2935 patients investigated to 5/6194 (83.1% reduction; P Clean programme was associated with marked reductions in new VRE colonizations in high-risk patients, and VRE bacteraemia across the entire hospital. These findings have important implications for VRE control in endemic healthcare settings. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Operational experience of the fuel cleaning facility of Joyo

    International Nuclear Information System (INIS)

    Mukaibo, R.; Matsuno, Y.; Sato, I.; Yoneda, Y.; Ito, H.

    1978-01-01

    Spent fuel assemblies in 'Joyo', after they are taken out of the core, are taken to the Fuel Cleaning Facility in the reactor service building and sodium removal is done. The cleaning process is done by cooling the assembly with argon gas, steam charging and rinsing by demineralized water. Deposited sodium was 50 ∼ 60 g per assembly. The sodium and steam reaction takes about 15 minutes to end and the total time the fuel is placed in the pot is about an hour. The total number of assemblies cleaned in the facility was 95 as of November 1977. In this report the operational experience together with discussions of future improvements are given. (author)

  5. Operational experience of the fuel cleaning facility of Joyo

    Energy Technology Data Exchange (ETDEWEB)

    Mukaibo, R; Matsuno, Y; Sato, I; Yoneda, Y; Ito, H [O-arai Engineering Centre, PNC, Ibaraki-ken, Tokio (Japan)

    1978-08-01

    Spent fuel assemblies in 'Joyo', after they are taken out of the core, are taken to the Fuel Cleaning Facility in the reactor service building and sodium removal is done. The cleaning process is done by cooling the assembly with argon gas, steam charging and rinsing by demineralized water. Deposited sodium was 50 {approx} 60 g per assembly. The sodium and steam reaction takes about 15 minutes to end and the total time the fuel is placed in the pot is about an hour. The total number of assemblies cleaned in the facility was 95 as of November 1977. In this report the operational experience together with discussions of future improvements are given. (author)

  6. [Analysis and research on cleaning points of HVAC systems in public places].

    Science.gov (United States)

    Yang, Jiaolan; Han, Xu; Chen, Dongqing; Jin, Xin; Dai, Zizhu

    2010-03-01

    To analyze cleaning points of HVAC systems, and to provides scientific base for regulating the cleaning of HVAC systems. Based on the survey results on the cleaning situation of HVAC systems around China for the past three years, we analyzes the cleaning points of HVAC systems from various aspects, such as the major health risk factors of HVAC systems, the formulation strategy of the cleaning of HVAC systems, cleaning methods and acceptance points of the air ducts and the parts of HVAC systems, the onsite protection and individual protection, the waste treatment and the cleaning of the removed equipment, inspection of the cleaning results, video record, and the final acceptance of the cleaning. The analysis of the major health risk factors of HVAC systems and the formulation strategy of the cleaning of HVAC systems is given. The specific methods for cleaning the air ducts, machine units, air ports, coil pipes and the water cooling towers of HVAC systems, the acceptance points of HVAC systems and the requirements of the report on the final acceptance of the cleaning of HVAC systems are proposed. By the analysis of the points of the cleaning of HVAC systems and proposal of corresponding measures, this study provides the base for the scientific and regular launch of the cleaning of HVAC systems, a novel technology service, and lays a foundation for the revision of the existing cleaning regulations, which may generate technical and social benefits to some extent.

  7. Steam generator cleaning campaigns at Bruce A: 1993-1996

    International Nuclear Information System (INIS)

    Puzzuoli, F.V.; Leinonen, P.J.; Lowe, G.A.

    1997-01-01

    Boiler chemical cleaning (BOCC) and high-pressure water lancing operations were performed during the Bruce A 1993 Unit 3, 1994 Unit 3, 1995 Unit 1 and 1996 Unit 3 outages to remove secondary side deposits. High-pressure water lancing focused on three boiler areas: tube support plates, to remove broached hole deposits, hot leg U-bend supports to dislodge deposits contributing to boiler tube stress corrosion cracking and tube sheets with the aim of removing accumulated sludge piles and post BOCC insoluble residues. The chemical cleaning processes applied were modified versions of the one developed by the Electric Power Research Institute/Steam Generator Owners Group. During these BOCC operations, corrosion for several key boiler materials was monitored and was well below the specified allowances

  8. Wet self-cleaning of superhydrophobic microfiber adhesives formed from high density polyethylene.

    Science.gov (United States)

    Lee, Jongho; Fearing, Ronald S

    2012-10-30

    Biologically inspired adhesives developed for switchable and controllable adhesion often require repetitive uses in general, dirty, environments. Superhydrophobic microstructures on the lotus leaf lead to exceptional self-cleaning of dirt particles on nonadhesive surfaces with water droplets. This paper describes the self-cleaning properties of a hard-polymer-based adhesive formed with high-aspect-ratio microfibers from high-density polyethylene (HDPE). The microfiber adhesive shows almost complete wet self-cleaning of dirt particles with water droplets, recovering 98% of the adhesion of the pristine microfiber adhesives. The low contact angle hysteresis indicates that the surface of microfiber adhesives is superhydrophobic. Theoretical and experimental studies reveal a design parameter, length, which can control the adhesion without affecting the superhydrophobicity. The results suggest some properties of biologically inspired adhesives can be controlled independently by adjusting design parameters.

  9. Proposed prediction algorithms based on hybrid approach to deal with anomalies of RFID data in healthcare

    Directory of Open Access Journals (Sweden)

    A. Anny Leema

    2013-07-01

    Full Text Available The RFID technology has penetrated the healthcare sector due to its increased functionality, low cost, high reliability, and easy-to-use capabilities. It is being deployed for various applications and the data captured by RFID readers increase according to timestamp resulting in an enormous volume of data duplication, false positive, and false negative. The dirty data stream generated by the RFID readers is one of the main factors limiting the widespread adoption of RFID technology. In order to provide reliable data to RFID application, it is necessary to clean the collected data and this should be done in an effective manner before they are subjected to warehousing. The existing approaches to deal with anomalies are physical, middleware, and deferred approach. The shortcomings of existing approaches are analyzed and found that robust RFID system can be built by integrating the middleware and deferred approach. Our proposed algorithms based on hybrid approach are tested in the healthcare environment which predicts false positive, false negative, and redundant data. In this paper, healthcare environment is simulated using RFID and the data observed by RFID reader consist of anomalies false positive, false negative, and duplication. Experimental evaluation shows that our cleansing methods remove errors in RFID data more accurately and efficiently. Thus, with the aid of the planned data cleaning technique, we can bring down the healthcare costs, optimize business processes, streamline patient identification processes, and improve patient safety.

  10. Facile fabrication of uniform hierarchical structured (UHS) nanocomposite surface with high water repellency and self-cleaning properties

    Science.gov (United States)

    Bagheri, H.; Aliofkhazraei, M.; Forooshani, H. Mojiri; Rouhaghdam, A. Sabour

    2018-04-01

    In the present study, two-stage process for the fabrication of superhydrophobic Ni-Cu-TiO2 nanocomposite coatings on the copper substrate has been introduced. Surface modification was performed on the electrodeposited coatings by myristic acid-ethanol solution to achieve superhydrophobicity. Additionally, in order to further study the roughness effect, instead of addition of copper ions in electrodeposition bath, three substrates were roughened by electrochemical etching method. Water repellency properties were studied through measurement of static and dynamic contact angles, and performing bouncing test, self-cleaning and water-jet evaluation. The samples were electrodeposited in various current densities, and the highest corrosion resistance and water repellency properties were obtained for the sample which was electrodeposited in two consecutive steps and modified by a fatty acid called myristic acid (which significantly reduces surface energy of the coating). The highest water contact angle (161°) and the lowest contact angle hysteresis (3°) were obtained for the sample which was coated by 10 mA/cm2 (144 min) and 20 mA/cm2 (18 min), respectively. Since this approach does not require any sophisticated equipment and materials, it shows promising future in the fabrication of superhydrophobic coatings.

  11. Sorbent Nanotechnologies for Water Cleaning

    Science.gov (United States)

    Ahmed, Snober

    Despite decades of regulatory efforts to mitigate water pollution, many chemicals, particularly heavy metals, still present risks to human health. In addition to direct exposure, certain metals such as mercury threaten public health due to its persistence, bioaccumulation and bioamplification throughout the food chain. A number of U.S. Federal and State regulations have been established to reduce the levels of mercury in water. Activated carbon (AC) has been widely explored for the removal of mercury. However, AC suffers from many limitations inherent to its chemical properties, and it becomes increasingly challenging to meet current and future regulations by simply modifying AC to enhance its performance. Recently, the performance of nanosorbents have been studied in order to removal pollutants. Nanosorbents utilize the ultra-high reactive surface of nanoparticles for rapid, effective and even permanent sequestration of heavy metals from water and air, thus showed promising results as compared to AC. The goal of this thesis research is to develop nanomaterial-based sorbents for the removal of mercury from water. It describes the development of a new solid-support assisted growth of selenium nanoparticles, their use for water remediation, and the development of a new nanoselenium-based sorbent sponge for fast and efficient mercury removal. The nanoselenium sorbent not only shows irreversible interaction with mercury but also exhibits remarkable properties by overcoming the limitations of AC. The nanoselenium sponge was shown to remove mercury to undetectable levels within one minute. This new sponge technology would have an impact on inspiring new stringent regulations and lowering costs to help industries meet regulatory requirements, which will ultimately help improve air and water quality, aquatic life and public health.

  12. Clean Cities Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    2004-01-01

    This fact sheet explains the Clean Cities Program and provides contact information for all coalitions and regional offices. It answers key questions such as: What is the Clean Cities Program? What are alternative fuels? How does the Clean Cities Program work? What sort of assistance does Clean Cities offer? What has Clean Cities accomplished? What is Clean Cities International? and Where can I find more information?

  13. Low temperature self-cleaning properties of superhydrophobic surfaces

    Science.gov (United States)

    Wang, Fajun; Shen, Taohua; Li, Changquan; Li, Wen; Yan, Guilong

    2014-10-01

    Outdoor surfaces are usually dirty surfaces. Ice accretion on outdoor surfaces could lead to serious accidents. In the present work, the superhydrophobic surface based on 1H, 1H, 2H, 2H-Perfluorodecanethiol (PFDT) modified Ag/PDMS composite was prepared to investigate the anti-icing property and self-cleaning property at temperatures below freezing point. The superhydrophobic surface was deliberately polluted with activated carbon before testing. It was observed that water droplet picked up dusts on the cold superhydrophobic surface and took it away without freezing at a measuring temperature of -10 °C. While on a smooth PFDT surface and a rough surface base on Ag/PDMS composite without PFDT modification, water droplets accumulated and then froze quickly at the same temperature. However, at even lower temperature of -12 °C, the superhydrophobic surface could not prevent the surface water from icing. In addition, it was observed that the frost layer condensed from the moisture pay an important role in determining the low temperature self-cleaning properties of a superhydrophobic surface.

  14. Laser surface cleaning

    International Nuclear Information System (INIS)

    Freiwald, J.G.; Freiwald, D.A.

    1994-01-01

    The objective of this work is a laboratory demonstration that red-lead primer and two-part epoxy paints can be stripped from concrete and metal surfaces using surface cleaning systems based on pulsed-repetition CO 2 lasers. The three goals are to: (1) demonstrate coatings removal, including surface pore cleaning; (2) demonstrate that there is negligible release of ablated contaminants to the environment; and (3) demonstrate that the process will generate negligible amounts of additional waste compared to competing technologies. Phase 1 involved site visits to RMI and Fernald to assess the cleaning issues for buildings and parts. In addition, Phase 1 included detailed designs of a more powerful system for industrial cleaning rates, including laser, articulating optics, ablated-material capture suction nozzle attached to a horizontal raster scanner for floor cleaning, and filtration system. Some concept development is also being done for using robots, and for parts cleaning. In Phase 2 a transportable 6 kW system will be built and tested, with a horizontal surface scanner for cleaning paint from floors. The laboratory tests will again be instrumented. Some concept development will continue for using robots, and for parts cleaning. This report describes Phase 1 results

  15. The Cost of Clean Water in the Delaware River Basin (USA

    Directory of Open Access Journals (Sweden)

    Gerald J. Kauffman

    2018-01-01

    Full Text Available The Delaware River has made a marked recovery in the half-century since the adoption of the Delaware River Basin Commission (DRBC Compact in 1961 and passage of the Federal Clean Water Act amendments during the 1970s. During the 1960s, the DRBC set a 3.5 mg/L dissolved oxygen criterion for the river based on an economic analysis that concluded that a waste load abatement program designed to meet fishable water quality goals would generate significant recreational and environmental benefits. Scientists with the Delaware Estuary Program have recently called for raising the 1960s dissolved oxygen criterion along the Delaware River from 3.5 mg/L to 5.0 mg/L to protect anadromous American shad and Atlantic sturgeon, and address the prospect of rising temperatures, sea levels, and salinity in the estuary. This research concludes, through a nitrogen marginal abatement cost (MAC analysis, that it would be cost-effective to raise dissolved oxygen levels to meet a more stringent standard by prioritizing agricultural conservation and some wastewater treatment investments in the Delaware River watershed to remove 90% of the nitrogen load by 13.6 million kg N/year (30 million lb N/year for just 35% ($160 million of the $449 million total cost. The annual least cost to reduce nitrogen loads and raise dissolved oxygen levels to meet more stringent water quality standards in the Delaware River totals $45 million for atmospheric NOX reduction, $130 million for wastewater treatment, $132 million for agriculture conservation, and $141 million for urban stormwater retrofitting. This 21st century least cost analysis estimates that an annual investment of $50 million is needed to reduce pollutant loads in the Delaware River to raise dissolved oxygen levels to 4.0 mg/L, $150 million is needed for dissolved oxygen levels to reach 4.5 mg/L, and $449 million is needed for dissolved oxygen levels to reach 5.0 mg/L.

  16. Effectiveness of Runoff Control Legislation and Active, Beautiful, Clean (ABC Waters Design Features in Singapore

    Directory of Open Access Journals (Sweden)

    Xue Ping Goh

    2017-08-01

    Full Text Available Storm water management in Singapore has always been a challenge due to intense rainfall in a flat, low-lying and urbanised catchment. PUB’s (Singapore’s National Water Agency recent runoff control regulation limits the runoff coefficient to 0.55 for developments larger than or equal to 0.2 ha. The use of Active, Beautiful, Clean (ABC Waters design features are encouraged to attain peak runoff reduction. Hence the paper focuses on (i determining the actual hydrological response regime of Singapore using the relationship between runoff coefficient (C, land use and slope; and (ii investigating the effectiveness of ABC Waters design features in delaying and reducing peak runoff using a modelling approach. Based on a Storm Water Management Model (SWMM model and using elevation, land use and soil data as inputs, the peak C-values were obtained for 50 m × 50 m grid cells. The results show that for the same land use, the one with steeper slope resulted in a higher runoff coefficient. Simulations were carried out in two study areas, Green Walk District and Tengah Subcatchment, where ABC Waters design features (such as porous pavements, green roofs, rain gardens and detention tanks were incorporated to reduce C-values. Results showed that peak C-values can be reduced to less than 0.55 after increasing the green areas and constructing detention facilities. Reduction in peak discharge (22% to 63% and a delay in peak discharge by up to 30 min were also observed. Hence, it is recommended to consider the relationship between slope and land use while determining runoff coefficients; and to incorporate ABC Waters design features in urban design to reduce the peak flow and runoff coefficient (C.

  17. The impact of chemical cleaning on separation efficiency and properties of reverse osmosis membrane

    KAUST Repository

    Baatiyyah, Hani

    2018-04-01

    One of most major concerns from both cost-effective and technical point of view in membrane process industry is membrane cleaning. The aim of the project was to investigate the variations in membrane surface properties and separation efficiency of reverse osmosis membrane. Compativtive analysis have to be performed on four RO membrane before and after exposing the virgin membrane into chemical cleaning to identify and analysis the impact of the chemical cleaning on the performance of RO membrane. Commerical chemical cleaning used in this project were caustic and acidic cleaning agent. The project’s aim is the investigation of simulation software’s precision for the four membranes performance projection at different conditions of the feed water. The assessment of the membranes performance was done in the Innovation Cluster at pilot plant that was industrial in size. The main commercial elements used were the thin-film composite membranes with a spiral-wound of 8-inch polyamide. Ultrafiltration (UF) and seawater RO membrane pretreatment process was done for the red sea sourced feed water. A pressure vessel dimensioned at 8-inch was operated in conjunction with an individual element at 8 -20 m3/hr feed flow rate, with an 8 to 12 % recovery and an average 35,000-42,000 mg/L of total dissolved solids (TDS) composition for the feed water. To achieve the project’s aim in assessing the membranes, three phase experimental stages were completed. The membranes performance was assessed in terms of their water flux, salt rejection, boron rejection, bicarbonate rejection and permeate quality. In addition, the membrane surfaces were characterized after exposing the fresh membranes with a chemical cleaning reagent. The experimental results showed an increase in both permeate flow and salt passage for all studied elements. The changes in the membranes performance were systematically explained based on the changes in the charge density and chemical structure of the membranes

  18. Ultra-clean

    International Nuclear Information System (INIS)

    Hergenroether, K.

    1987-01-01

    No other method guarantees such a thorough cleaning of contaminated materials' surfaces. Only ultrasound can reach those cavities crevices and corners where any manual cleaning fails. Furthermore there is no cumbersome and time-consuming manual decontamination which often has to be carried out in glove boxes and hot cells. Depending on the design the cleaning effect can reach from removing adhering dirt particles to removing complete surface layers. (orig./PW) [de

  19. Clean Energy Solutions Center: Assisting Countries with Clean Energy Policy

    Science.gov (United States)

    advice on financing instruments. In a recent keynote to the Climate and Clean Energy Investment Forum renewable energy technologies in the country. Informing Energy Access and Clean Energy Project Finance understanding and knowledge of how to design policies that enable financing and encourage investment in clean

  20. Intelligent Sensor for Autonomous Cleaning in livestock buildings (ISAC) - A challenge in bioenvironmental engineering

    DEFF Research Database (Denmark)

    Strøm, J.S.; Zhang, G.; Blanke, Mogens

    2003-01-01

    Manual cleaning of livestock buildings, using high-pressure water technology, is one of the most tedious and health threatening tasks which is conducted by human labour. The cleaning process itself contributes to deterioration of the working environment due to stirring up dirt, microorganisms...

  1. Design of segmental ultrasonic cleaning equipment for removing the sludge in a steam generator

    International Nuclear Information System (INIS)

    Kim, Seok Tae; Jeong, Woo Tae; Byeon, Min Suk; Lee, Ho One

    2010-01-01

    In nuclear power plants, the water in the coolant system is managed to be clean but metallic sludge is accumulated on the top of tube-sheet in a steam generator. The sludge causes the corrosion of the tubesheet. The electric utility company in Korea removes the sludge with a lancing system for every outage of nuclear power plants. But the sludge is not perfectly removed with lancing system because the pressurized water of the lancing system cannot reach all area in a steam generator. Therefore the steam generator cleaning system with ultrasonic energy has been developed in KEPCO Research Institute. In this paper, the ultrasonic cleaning system is designed for removing the sludge on the steam generator

  2. Corrosion and cleaning aspects of sodium side crevices in components of LMFBR's

    International Nuclear Information System (INIS)

    Chirer, E.G.

    1978-01-01

    Although the presence of crevices is excluded in critical areas of sodium components by design, their occurrence in other areas cannot be eliminated completely. During the lifetime of a component high concentrations of sodium compounds, such as caustics, may be formed in crevices. These compounds can remain within the crevices for some time. In this respect the following situations are recognized: - Reaction products from initial contaminants such as oxide scales. The component with crevices containing oxide scale either from the manufacturing process or insufficient cleaning after water pressure testing is exposed to sodium during actual operation. - Reaction products formed during or after cleaning. Sodium in the crevices of a drained component reacts with water vapour or water during cleaning or during subsequent storing or handling under non-perfect conditions. Before refilling with sodium the component is heated to preheat temperature. Same situation as above, however the component is exposed to sodium at operating temperature. These cycles can be repeated several times. - Products from a small sodium-water reaction. Caustic products from a small sodium-water reaction may be present in crevices or dead ends of a component which is exposed to high temperature during sodium operation or during vacuum distillation. The aims of the investigations are: determination of the corrosive aspects of high concentration of caustic reaction products of sodium in crevices on the structural materials of the component; comparison of the effectiveness of different cleaning procedures in respect to removal of sodium from crevices, e.g. water, steam, alcohol cleaning, vacuum distillation. Concerning the first item, in particular the possibility of the occurrence of intercrystalline corrosion and stress corrosion cracking is investigated. Materials investigated are the Cr-Mo steels 2 1/4Cr1Mo stabilized with Nb, 9Cr1Mo, 12Cr1Mo and the austenitic stainless steal AISI 304. The

  3. Royal Wine Corporation d/b/a/ Royal Kedem (Herzog Wine Cellars), Oxnard, CA; Proposed Settlement of Clean Water Act Class II Administrative Penalty and Opportunity to Comment

    Science.gov (United States)

    Public Notice of Proposed Settlement of Clean Water Act Class II Administrative Penalty and Opportunity to Comment In the Matter of Royal Wine Corporation d/b/a/ Royal Kedem (Herzog Wine Cellars), Oxnard, California.

  4. Renewable Natural Gas Clean-up Challenges and Applications

    Science.gov (United States)

    2011-01-13

    produced from digesters ─ Animal manure (dairy cows, swine ) ─ Waste water treatment facilities > Methane from Landfills > RNG produced from...LNG) for vehicle fuel ─Ft. Lewis — Anaerobic digestion of waste water for production of hydrogen as a fuel cell vehicle fuel ─SCRA * – Landfill gas...BE CLEANED- UP AND PLACED IN THE NATURAL GAS PIPELINE SYSTEM 6 GTI RNG Project Examples >Example GTI Projects: ─Gills Onions— Anaerobic

  5. CHEMICAL AND ENERGETIC CONTENT OF CORN BEFORE AND AFTER PRE-CLEANING

    Directory of Open Access Journals (Sweden)

    Sandra Iara Furtado Costa Rodrigues

    2015-04-01

    Full Text Available The poultry industry normally has little control over the raw material that arrives at the processing plant. This experiment aimed to evaluate chemical and energetic quality of corn obtained in a feed mill before and after pre-cleaning. Twenty samples of 30 kg of corn each were taken from trucks delivering corn to the mill. The trucks were then unloaded and the material passed through a pre-cleaning process when another sample was taken. Samples were graded and physical properties evaluated: density (g/L, grain percentages of foreign material, impurities, fragments, broken, soft, insect damaged, fire-burnt, fermented, damaged, cracked and fine particles, as well as chemical composition analysis: Apparent metabolizable energy for poultry (AME, ether extract (EE, crude fiber (CF, starch (STA, water activity (WA, crude protein (CP, digestible and total lysine, methionine, cystine, threonine, tryptophan, valine, isoleucine, leucine, phenylalanine, histidine and arginine. The experiment was a randomized design with two treatments (before and after pre-cleaning and twenty replications. Data was analyzed using SAS ® and treatment differences obtained using F test. Correlations and principal components were calculated. There was a decrease in density after the pre-cleaning process, which was probably due to the removal of earth and stones rather than grain and its fractions. Significant increases were found for insect damage, fermented and damaged grain while fire-burn was significantly reduced after the pre-cleaning process. Starch increased after pre-cleaning which is a result of contaminants that normally are poor in this carbohydrate, but fiber levels increased too. Apparent metabolizable energy, aminoacids, digestible (P<0.05 and total (P<0.05 histidine, total lysine and methionine (P<0.1 levels were reduced after pre-cleaning. Density was higher when there were fewer impurities such as straw, husk or small grains. Broken corn was positively

  6. Efficient methods of nanoimprint stamp cleaning based on imprint self-cleaning effect

    Energy Technology Data Exchange (ETDEWEB)

    Meng Fantao; Chu Jinkui [Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, 116024 Dalian (China); Luo Gang; Zhou Ye; Carlberg, Patrick; Heidari, Babak [Obducat AB, SE-20125 Malmoe (Sweden); Maximov, Ivan; Montelius, Lars; Xu, H Q [Division of Solid State Physics, Lund University, Box 118, S-22100 Lund (Sweden); Nilsson, Lars, E-mail: ivan.maximov@ftf.lth.se [Department of Food Technology, Engineering and Nutrition, Lund University, Box 117, S-22100 Lund (Sweden)

    2011-05-06

    Nanoimprint lithography (NIL) is a nonconventional lithographic technique that promises low-cost, high-throughput patterning of structures with sub-10 nm resolution. Contamination of nanoimprint stamps is one of the key obstacles to industrialize the NIL technology. Here, we report two efficient approaches for removal of typical contamination of particles and residual resist from stamps: thermal and ultraviolet (UV) imprinting cleaning-both based on the self-cleaning effect of imprinting process. The contaminated stamps were imprinted onto polymer substrates and after demolding, they were treated with an organic solvent. The images of the stamp before and after the cleaning processes show that the two cleaning approaches can effectively remove contamination from stamps without destroying the stamp structures. The contact angles of the stamp before and after the cleaning processes indicate that the cleaning methods do not significantly degrade the anti-sticking layer. The cleaning processes reported in this work could also be used for substrate cleaning.

  7. How clean is clean?---How clean is needed?

    International Nuclear Information System (INIS)

    Hays, A.K.

    1991-01-01

    This paper will provide an overview of cleaning qualifications used in a variety of industries: from small-scale manufacturer's of precision-machined products to large-scale manufacturer's of electronics (printed wiring boards and surface mount technology) and microelectronics. Cleanliness testing techniques used in the production of precision-machined products, will be described. The on-going DOD program to obtain high-reliability electronics, through the use of military specifications for cleaning and cleanliness levels, will be reviewed. In addition, the continually changing cleanroom/materials standards of the microelectronics industry will be discussed. Finally, we will speculate on the role that new and improved analytical techniques and sensor technologies will play in the factories of the future. 4 refs., 1 tab

  8. HACCP and the management of healthcare associated infections: are there lessons to be learnt from other industries?

    Science.gov (United States)

    Griffith, Chris

    2006-01-01

    Hospital cleaning and healthcare associated infections (HCAIs) continue to attract adverse media attention and consumer concern. Parallels exist with similar publicity relating to cleaning and food safety in the food industry almost 13 years earlier. This paper examines some of the management solutions developed in the food industry, and discusses their application to healthcare delivery. The food industry is managing food safety by adopting a dual approach based on pre-requisite programmes and Hazard Analysis Critical Control Points (HACCP). How these differ is described and how the approaches and terminology can be adapted for use in healthcare is discussed. The food industry is moving towards external certification of safety using national and international standards. The HACCP approach, a management tool and a central requirement of these standards, is evolving and there is interest worldwide from the healthcare community. Its application to the decontamination of endoscopes, using conventional HACCP, is presented, as well as suggestions for a simplified format for managing patient-related procedures. Taking this type of approach to the management of HCAIs could provide greater transparency, reduce infection rates and increase consumer confidence. Potential problems in adopting HACCP, including cost and human resource, are discussed. The HACCP method/approach has previously been mentioned in the medical literature but this paper is one of the few to examine, from basic principles, its infection control application within a broader approach to quality assurance.

  9. Water accounting implementation: water footprint and water efficiency of the coffee shop in Indonesia

    Science.gov (United States)

    Hendratno, S. P.; Agustine, Y.

    2018-01-01

    The purpose of this paper is for understand the water accounting practice in the company, especially beverage industry in Indonesia. The sample in this study is one coffee shop near Jakarta. Case study has been choosen as the method in this study. We collect data with semi-structured interview, observation, and survey about the water efficiency in the coffee shop. The operational officers such as barista, cashier, supervisor, and store manager are the respondents in this study. Operational management already understand about the importance of water efficiency in the coffee shop operation, but it can’t be implemented because their standard operation haven’t use the water efficiency as part of their procedures. The coffee shop’s operational standard in cleaning always takes much time and use so much water. The cleaning itself takes one until two hours each day only for cleaning bar and all operational equipment. This paper is for understand the water efficiency in the coffee shop with the focus is in their water footprint, operational standard that used every day in the coffee shop, and the connection between operational standard and the water efficiency.

  10. New NOx cleaning technology helps the government fulfil promise

    International Nuclear Information System (INIS)

    2006-01-01

    The Norwegian, Bergen-based company ECO Energy has recently launched a new cleaning technology halving NO x emissions from industry plants without requiring large investments. Thus, governmental promises to finance NO x cleaning equipment for Norwegian industry have become a less expensive to reach. ECO Energy has ensured world patent on the 'stopNOx' technology. Its method consists of adding water and urea to oil before the combustion process. The technology has been applied in Italy, reducing NO x emissions from industry in average with above 50 percent (ml)

  11. National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware

    International Nuclear Information System (INIS)

    Gabor, K

    2001-01-01

    When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and material, but also produce cleaned parts that meet the stringent NIF cleanliness standards (MIL-STD-1246C Level 83 for particles and A/10 for non-volatile residue). Each unit was designed with extensive water- and energy-conserving features, and the technology used minimizes hazardous waste generation associated with solvent wipe cleaning, the traditional method for cleaning laser mechanical components. The LMPGC provides preliminary gross cleaning for large mechanical parts. Collection, filtration and reuse of the wash and primary rinse water in the LMPGC limit its routine discharge to the volume of the low-pressure, deionized secondary rinse. After an initial gross cleaning in the LMPGC, a large mechanical part goes to the LMPPC. This piece of equipment, unique because of its size, consists of four 2700-gallon tanks. Parts held securely on specialized metal pallets (jointly weighing up to 1500 pounds) move through the tanks on an automated system. Operators program all movement, speeds and process times to

  12. Optimization of waste water discharge and waste water cleaning on the basis of measurements of the organic pollutant load; Optimierung von Abwasserableitung und Abwasserreinigung durch Messung der organischen Abwasserbelastung

    Energy Technology Data Exchange (ETDEWEB)

    Haeck, M. [Dr. Bruno Lange GmbH Berlin, Duesseldorf (Germany)

    1999-07-01

    The spectral absorption coefficient (SAC) is a sum parameter for describing the organic pollutant load of waste water. It is based on a purely physical measuring technique and can be monitored continuously and directly in the medium by means of the described UV process probe. From this arise numerous opportunities for optimizing waste water discharge and cleaning. (orig.) [German] Der spektrale Absorptionskoeffizient (SAK) ist ein Summenparameter zur Beschreibung der organischen Abwasserbelastung. Er basiert auf einem rein physikalischen Messverfahren und kann mit der hier vorgestellten UV-Prozess-Sonde kontinuierlich und direkt im Medium erfasst werden. Daraus ergeben sich zahlreiche Moeglichkeiten zur Optimierung von Abwasserableitung und -reinigung. (orig.)

  13. Application of rapid read-out cleaning indicators for improved process control in hospital sterile services departments.

    Science.gov (United States)

    Nugent, P G; Modi, T; McLeod, N; Bock, L J; Smith, C; Poolman, T M; Warburton, R; Meighan, P; Wells, P; Sutton, J M

    2013-05-01

    Heightened awareness of the importance of cleaning has led to an emphasis on automated systems for the decontamination of re-usable medical devices. The authors have previously described an enzymatic indicator system, based on thermostable adenylate kinases (tAK), for quantitative monitoring of automated cleaning processes within hospital sterile services departments (SSDs). To evaluate tAK indicators for routine process monitoring across a range of SSDs with different cleaning chemistries and different automated washer disinfectors (AWDs). tAK indicator devices and alternative industry test indicators were included in five independent cleaning cycles in each of eight different AWDs. Residual tAK post wash was determined by a coupled luciferase assay using a modified hygiene monitoring system. In all cases, with the exception of a single test, the alternative indicators showed that cleaning had been adequate. They were not able to discriminate between the performance of different processes. In contrast, the tAK indicators were able to resolve differences in the performance of processes across the different SSDs. Where the tAK indicators identified cleaning to the limits of detection of the assay, this demonstrated a log10 enzyme removal factor of >5.69. The results suggest that tAK indicators are suitable for providing improved process control for automated cleaning processes, being able to distinguish between wash performance in different hospital settings and between individual process runs. This technology is believed to be a useful addition to routine AWD performance qualification when used as a daily or weekly test. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Clean coal technology challenges for China

    Energy Technology Data Exchange (ETDEWEB)

    Mao, J. [Tsinghua University, Beijing (China). Dept. of Thermal Engineering

    2001-01-01

    China is rich in coal reserves and also the largest coal producer and consumer in the world. Coal constitutes over 70% of the total energy consumption, some 86% of coal production is burned directly, which causes serious air pollution problems. However, based on China's specific energy structure, coal utilisation will remain the dominant means of energy usage and clean coal technology must be the way forward if the environmental problems are to be resolved. This article discusses China's Clean Coal Technology Program, its implementation, including the clean coal technologies being developed and introduced, with reference to the key R & D institutes for each of the coal-using sectors. The article is an edited version of the 2000 Robens Coal Science Lecture, delivered in London in October 2000. The China Coal Technology Program for the 9th Five-Year Plan (1996-2000) was approved in 1997. The technologies included in the Program considered in this article are in: coal washing and grading, coal briquette, coal water slurry; circulating fluidised bed technology; pressurised fluidised bed combined cycle; integrated gasification combined cycle; coal gasification, coal liquefaction and flue gas desulfurisation. 4 tabs.

  15. Cleaning protocol for a FO membrane fouled in wastewater reuse

    KAUST Repository

    Valladares Linares, Rodrigo; Li, Zhenyu; Yangali-Quintanilla, Victor; Li, Qingyu; Amy, Gary L.

    2013-01-01

    Forward osmosis (FO) is an emerging technology which can be applied in water reuse applications. Osmosis is a natural process that involves less energy consumption than reverse osmosis (RO), and therefore can be applied as a dilution process before low-pressure RO; it is expected to compete favourably against current advanced water reuse technologies that use microfiltration/ultrafiltration and RO. The focus of this research was to assess the efficiency of different cleaning procedures to remove fouling from the surface of a FO membrane during the operation of a submerged system working in FO-mode (active layer (AL) facing feed solution) intended for secondary wastewater effluent (SWWE) recovery, using seawater as draw solution (DS), which will be diluted and can further be fed to a low-pressure RO unit to produce fresh water. Natural organic matter (NOM) fouling was expected to affect the AL, while for the support layer (SL), transparent exopolymer particles (TEP) were used as indicators of fouling due to their stickiness and propensity to enhance the attachment of other foulants in seawater on the membrane surface. The composition of the NOM fouling layer was determined after proper characterisation with a liquid chromatograph coupled with organic carbon detection (LC-OCD), showing biopolymers and protein-like substances as the main constituents. NOM fouling showed high hydraulic reversibility after a 25% flux decline was observed, up to 89.5% when in situ air scouring for 15 min was used as a cleaning technique. Chemical cleaning with a mixture of Alconox, an industrial detergent containing phosphates, and sodium EDTA showed to increase the reversibility (93.6%). Osmotic backwash using a 4% NaCl solution and DI water proved to be ineffective to recover flux due to the salt diffusion phenomena occurring at the AL. Part of the flux that could not be recovered is attributable to TEP fouling on the SL, which forms clusters clearly identifiable with an optical

  16. Cleaning protocol for a FO membrane fouled in wastewater reuse

    KAUST Repository

    Valladares Linares, Rodrigo

    2013-05-30

    Forward osmosis (FO) is an emerging technology which can be applied in water reuse applications. Osmosis is a natural process that involves less energy consumption than reverse osmosis (RO), and therefore can be applied as a dilution process before low-pressure RO; it is expected to compete favourably against current advanced water reuse technologies that use microfiltration/ultrafiltration and RO. The focus of this research was to assess the efficiency of different cleaning procedures to remove fouling from the surface of a FO membrane during the operation of a submerged system working in FO-mode (active layer (AL) facing feed solution) intended for secondary wastewater effluent (SWWE) recovery, using seawater as draw solution (DS), which will be diluted and can further be fed to a low-pressure RO unit to produce fresh water. Natural organic matter (NOM) fouling was expected to affect the AL, while for the support layer (SL), transparent exopolymer particles (TEP) were used as indicators of fouling due to their stickiness and propensity to enhance the attachment of other foulants in seawater on the membrane surface. The composition of the NOM fouling layer was determined after proper characterisation with a liquid chromatograph coupled with organic carbon detection (LC-OCD), showing biopolymers and protein-like substances as the main constituents. NOM fouling showed high hydraulic reversibility after a 25% flux decline was observed, up to 89.5% when in situ air scouring for 15 min was used as a cleaning technique. Chemical cleaning with a mixture of Alconox, an industrial detergent containing phosphates, and sodium EDTA showed to increase the reversibility (93.6%). Osmotic backwash using a 4% NaCl solution and DI water proved to be ineffective to recover flux due to the salt diffusion phenomena occurring at the AL. Part of the flux that could not be recovered is attributable to TEP fouling on the SL, which forms clusters clearly identifiable with an optical

  17. Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection.

    Science.gov (United States)

    Lee, Ji Yeon

    2016-10-01

    Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

  18. Mitigation of unionid mortality caused by zebra mussel infestation: cleaning of unionids

    Science.gov (United States)

    Schloesser, Don W.

    1996-01-01

    Exotic zebra mussels Dreissena polymorpha have infested and caused mortality of native unionids in the Great Lakes since 1986; no other such parasitism of native unionids occurs in North America. Survival of unionids threatened by zebra mussel infestation was tested by suspending uncleaned and cleaned unionids in nearshore waters of western Lake Erie. Survival was determined, and newly settled zebra mussels were removed from clean unionids at eight intervals that ranged from 21 d to 77 d between 5 July 1990 and 3 July 1991. After 1 year, survival rates of uncleaned and cleaned unionids were 0% and 42%, respectively. Of the 10 species examined, only indivduals from 3 species (Amblema plicata plicata, Fusconaia flava, and Quadrula quadrula) survived 1 year. These species have relatively thick shells, which may have contributed to their survival. Removal of newly settled zebra mussels may be important to unionid survival because 98% of the zebra mussels removed after the initial cleaning were small mussels (zebra mussels cause mortality of unionids, but the removal of zebra mussels from unionids is the only method known that successfully reduces unionid mortality in waters colonized by zebra mussels.

  19. Development of durable self-cleaning coatings using organic–inorganic hybrid sol–gel method

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Divya [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Wu, Xinghua [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Energy Research Institute at NTU - ERI@N, 1 CleanTech Loop, #06-04, CleanTech One, Singapore 637141 (Singapore); Fu, Qitao [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Ho, Jeffrey Weng Chye [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Energy Research Institute at NTU - ERI@N, 1 CleanTech Loop, #06-04, CleanTech One, Singapore 637141 (Singapore); Kanhere, Pushkar D. [Energy Research Institute at NTU - ERI@N, 1 CleanTech Loop, #06-04, CleanTech One, Singapore 637141 (Singapore); Li, Lin [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Chen, Zhong, E-mail: ASZChen@ntu.edu.sg [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Energy Research Institute at NTU - ERI@N, 1 CleanTech Loop, #06-04, CleanTech One, Singapore 637141 (Singapore)

    2015-07-30

    Highlights: • A facile method to produce sol–gel based self-cleaning coatings is described. • Effect of filler size and content is evaluated via contact angle, sliding angle, and surface morphology. • Coating with 15 wt.% nano-sized silica fillers exhibits the best self-cleaning performance. • The coatings are resistant to UV radiation and retain the functionality after the abrasion test. • A self-cleaning test and scheme to quantify the self-cleaning efficiency are described in this work. - Abstract: Self-cleaning coatings with excellent water-repellence and good mechanical properties are in high demand. However, producing such coatings with resistance to mechanical abrasion and environmental weathering remains a key challenge. Mechanically robust coatings based on tetraethylorthosilicate (TEOS) and glycidoxypropyltriethoxysilane (Glymo) have been prepared using a sol–gel method. Emphasis is given to the addition of Glymo, an epoxy silane which creates an organic matrix that blends with the inorganic Si−O−Si matrix formed from the TEOS. The combination of the blended matrix produced coatings with good adhesion to substrates and improved mechanical properties. Fluoroalkylsilane (FAS) and silica fillers were introduced to increase the hydrophobicity of the coating. It was found that the water contact angle (CA) of these coatings increases from 115° to 164° upon decreasing filler size from 1–5 μm to 10–20 nm. The sliding angle (SA) for coatings with 15 wt.% loading of 10–20 nm silica is around 2°. UV weathering does not show significant effect on the properties of the coatings. Mechanical properties and performances including hardness, Young's modulus, coating adhesion and abrasion resistance were systematically analyzed. In the current work, a simple self-cleaning test, which measures the extent of dirt accumulation and subsequent removal by water spray, was performed. The coatings with 15 wt.% loading of 10–20 nm silica particles

  20. Ultrasonic and immersion cleaning: a comparison using aqueous and fluorocarbon solvents

    International Nuclear Information System (INIS)

    Bond, R.D.; Kearsey, A.

    1984-11-01

    Decontamination is a necessary process in reducing radiation levels in the working environment in the nuclear industry. Components from active areas which require decontamination for re-use or maintenance operations. In this report, a typical chemical cleaning process using liquid pumping, airagitation and physical movement for agitation is compared with ultrasonic cleaning, now an established cleaning process in many industries. The chosen traditional method is immersion in an agitated solution of warm SDG.3 solution; an established decontaminating reagent. The decontamination effect of this process is compared with the effect of cleaning in an ultrasonic bath containing the same reagent at the same concentration and temperature. Fluorocarbon reagents are of particular interest to the nuclear industry for they offer the ability to clean electrical components without damage, and can clean product contaminated material without the risk of criticality. Such reagents are based on 1,1,2-trichloro, 1,2,2-trifluoroethane and azeotropic mixtures. This reagent and one mixture with 6% methanol were tested under agitation and ultrasonic immersion at the same temperature. Parallel control experiments were conducted using demineralised water as the cleaning media in an agitated bath. SGG3 is a good reagent for general purpose cleaning (it can remove 99% of particulate contamination) using scrubbing, immersion or spraying techniques. There is little evidence to show that ultrasonic cleaning increases its effectiveness. For special purpose fluorocarbon solvents will give satisfactory results when used in an ultrasonic system. (author)

  1. Floatable, Self-Cleaning, and Carbon-Black-Based Superhydrophobic Gauze for the Solar Evaporation Enhancement at the Air-Water Interface.

    Science.gov (United States)

    Liu, Yiming; Chen, Jingwei; Guo, Dawei; Cao, Moyuan; Jiang, Lei

    2015-06-24

    Efficient solar evaporation plays an indispensable role in nature as well as the industry process. However, the traditional evaporation process depends on the total temperature increase of bulk water. Recently, localized heating at the air-water interface has been demonstrated as a potential strategy for the improvement of solar evaporation. Here, we show that the carbon-black-based superhydrophobic gauze was able to float on the surface of water and selectively heat the surface water under irradiation, resulting in an enhanced evaporation rate. The fabrication process of the superhydrophobic black gauze was low-cost, scalable, and easy-to-prepare. Control experiments were conducted under different light intensities, and the results proved that the floating black gauze achieved an evaporation rate 2-3 times higher than that of the traditional process. A higher temperature of the surface water was observed in the floating gauze group, revealing a main reason for the evaporation enhancement. Furthermore, the self-cleaning ability of the superhydrophobic black gauze enabled a convenient recycling and reusing process toward practical application. The present material may open a new avenue for application of the superhydrophobic substrate and meet extensive requirements in the fields related to solar evaporation.

  2. Supply of clean water to the bearings and mechanical seals of the backup pumps; Alimentation en eau propre des paliers et garnitures mecaniques des pompes de sauvetage

    Energy Technology Data Exchange (ETDEWEB)

    Jolas, C. [Department Machines, Service Ensembles de Production, Direction des Etudes et Recherches, Electricite de France (EDF), 92 - Clamart (France)

    1997-01-01

    The purpose of the backup pumps is to cool the primary circuit and pressurised water reactor containment in the case of a primary cooler loss accident. The water taken in by these pumps in the case of accident is loaded with solid particles. In order to ensure correct operation of the bearings and mechanical seals of these machines, they must be supplied with clean water. In other words, the solid particles must be removed from the water intake. Manufacturers generally use cyclonic separators to achieve this. (author) 5 refs., 14 figs.

  3. Chemical cleaning/disinfection and ageing of organic UF membranes: a review.

    Science.gov (United States)

    Regula, C; Carretier, E; Wyart, Y; Gésan-Guiziou, G; Vincent, A; Boudot, D; Moulin, P

    2014-06-01

    Membrane separation processes have become a basic unit operation for process design and product development. These processes are used in a variety of separation and concentration steps, but in all cases, the membranes must be cleaned regularly to remove both organic and inorganic material deposited on the surface and/or into the membrane bulk. Cleaning/disinfection is a vital step in maintaining the permeability and selectivity of the membrane in order to get the plant to its original capacity, to minimize risks of bacteriological contamination, and to make acceptable products. For this purpose, a large number of chemical cleaning/disinfection agents are commercially available. In general, these cleaning/disinfection agents have to improve the membrane flux to a certain extent. However, they can also cause irreversible damages in membrane properties and performances over the long term. Until now, there is considerably less literature dedicated to membrane ageing than to cleaning/disinfection. The knowledge in cleaning/disinfection efficiency has recently been improved. But in order to develop optimized cleaning/disinfection protocols there still remains a challenge to better understand membrane ageing. In order to compensate for the lack of correlated cleaning/disinfection and ageing data from the literature, this paper investigates cleaning/disinfection efficiencies and ageing damages of organic ultrafiltration membranes. The final aim is to provide less detrimental cleaning/disinfection procedures and to propose some guidelines which should have been taken into consideration in term of membrane ageing studies. To carry out this study, this article will detail the background of cleaning/disinfection and aging membrane topics in a first introductive part. In a second part, key factors and endpoints of cleaning/disinfection and aging membranes will be discussed deeply: the membrane role and the cleaning parameters roles, such as water quality, storing conditions

  4. Cleaning ex-uranium sites in Easter Germany

    International Nuclear Information System (INIS)

    Gattsvajler, R.; Khagen, M.

    1995-01-01

    Consideration is given to problems, related with recovery and cleaning of ground and water, damaged during intensive uranium mining in the Easter Germany. Design and reclamation works, conducted in the framework of the unique project of Vismut company, are described. The consultation department of environment recovery for experience and technology propagation was organized in this company. 2 tabs

  5. Clean Slate 2 Revegetation and Monitoring Plan

    International Nuclear Information System (INIS)

    David Anderson

    1998-01-01

    This document is a reclamation plan for short-term and long-term stabilization of land disturbed by activities associated with interim clean-up of radionuclide-contaminated surface soil at Clean Slate 2 located northwest of the Nevada Test Site on the Nellis Air Force Range. Surface soils at Clean Slate 2 were contaminated as a result of the detonation of a device containing plutonium and depleted uranium using chemical explosives. Excavation of contaminated soils at Clean Slate 2 will follow procedures similar to those used during the cleanup of the Double Tracks and Clean Slate 1 sites. A maximum of approximately 33 cm (12 in) of the surface soils will be excavated and removed from the site. Near ground zero, where contamination levels are highest, approximately 2 m (7 ft) of soil may be removed. The maximum area to be excavated is estimated to be 18.4 hectares (45.4) acres. In addition to the disturbance associated with soil excavation, approximately 2.0 hectares (5.0) acres will be disturbed by the construction of staging areas and placement of support facilities. Short term stabilization consists of an application of a chemical soil stabilizer and long-term stabilizations involves the establishment of a permanent vegetative cover using selective native plant species, site preparation techniques, increasing organic matter and water holding capacity, irrigation to ensure seed germination and plant establishment. The cleanup site will be monitored to ensure success of revegetation and resuspension of soil particles is within established limits

  6. New, clean handling process introduced to improve cable quality

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, C G

    1990-05-01

    The clean room system introduced by Canada Wire and Cable Limited in its Toronto plant for its cable manufacturing operation is described. While clean room technology is common in the food processing industry, optical and aerospace manufacturing processes, this is the first time it has been applied to wire and cable extrusion in North America. The purpose of the clean compound handling system is to prevent particle contamination in the shielding and cable insulation materials, as part of an effort to prevent premature underground electric cable failures. Two rooms are dedicated to handling different types of insulation compound, two are dedicated to receiving semi-conducting shielding material, and the fifth room functions as an air lock for the two insulation rooms. The atmosphere is highly regulated with programmable logic control. The air supply filters capture 99.97% of all particles 0.3 microns or larger. The system also maintains air temperature, relative humidity and static pressure. The life variability of cross-linked polyethylene primary distribution cable is dependant on five factors: material purity, extra clean compound handling, cable design, manufacturing process, and installation and operation practices. The clean room system is expected to result in cable that is more resistant to water treeing failures. 2 figs.

  7. Clean data

    CERN Document Server

    Squire, Megan

    2015-01-01

    If you are a data scientist of any level, beginners included, and interested in cleaning up your data, this is the book for you! Experience with Python or PHP is assumed, but no previous knowledge of data cleaning is needed.

  8. Method of cleaning oil slicks and chemical spills

    International Nuclear Information System (INIS)

    Billings, L.

    1992-01-01

    This patent describes a method of cleaning a floating chemical spill on a body of water. It comprises: providing a quantity of popular bark-based pelleted or granular product, flotation means and a flexible net having openings generally smaller than the smallest whole pellet dimension of the pelleted product, spreading the net over a chemical spill on the body of water, connecting the floatation means to the net thereby supporting the net adjacent the surface of the body of water, placing the poplar bark-based product on the net, absorbing the floating chemical spill into the product, and removing the chemical soaked product from the body of water

  9. Healthcare liquid waste management.

    Science.gov (United States)

    Sharma, D R; Pradhan, B; Pathak, R P; Shrestha, S C

    2010-04-01

    The management of healthcare liquid waste is an overlooked problem in Nepal with stern repercussions in terms of damaging the environment and affecting the health of people. This study was carried out to explore the healthcare liquid waste management practices in Kathmandu based central hospitals of Nepal. A descriptive prospective study was conducted in 10 central hospitals of Kathmandu during the period of May to December 2008. Primary data were collected through interview, observation and microbiology laboratory works and secondary data were collected by records review. For microbiological laboratory works,waste water specimens cultured for the enumeration of total viable counts using standard protocols. Evidence of waste management guidelines and committees for the management of healthcare liquid wastes could not be found in any of the studied hospitals. Similarly, total viable counts heavily exceeded the standard heterotrophic plate count (p=0.000) with no significant difference in such counts in hospitals with and without treatment plants (p=0.232). Healthcare liquid waste management practice was not found to be satisfactory. Installation of effluent treatment plants and the development of standards for environmental indicators with effective monitoring, evaluation and strict control via relevant legal frameworks were realized.

  10. High-resolution clean-sc

    NARCIS (Netherlands)

    Sijtsma, P.; Snellen, M.

    2016-01-01

    In this paper a high-resolution extension of CLEAN-SC is proposed: HR-CLEAN-SC. Where CLEAN-SC uses peak sources in “dirty maps” to define so-called source components, HR-CLEAN-SC takes advantage of the fact that source components can likewise be derived from points at some distance from the peak,

  11. How 'healthy' are healthcare organizations? Exploring employee healthcare utilization rates among Dutch healthcare organizations.

    Science.gov (United States)

    Bronkhorst, Babette

    2017-08-01

    Occupational health and safety research rarely makes use of data on employee healthcare utilization to gain insight into the physical and mental health of healthcare staff. This paper aims to fill this gap by examining the prevalence of two relevant types of healthcare utilization among staff working in healthcare organizations: physical therapy and mental healthcare utilization. The paper furthermore explores what role employee and organizational characteristics play in explaining differences in healthcare utilization between organizations. A Dutch healthcare insurance company provided healthcare utilization records for a sample of 417 organizations employing 136,804 healthcare workers in the Netherlands. The results showed that there are large differences between and within healthcare industries when it comes to employee healthcare utilization. Multivariate regression analyses revealed that employee characteristics such as age and gender distributions, and healthcare industry, explain some of the variance between healthcare organizations. Nevertheless, the results of the analyses showed that for all healthcare utilization indicators there is still a large amount of unexplained variance. Further research into the subject of organizational differences in employee healthcare utilization is needed, as finding possibilities to influence employee health and subsequent healthcare utilization is beneficial to employees, employers and society as a whole.

  12. Water changed the cities

    DEFF Research Database (Denmark)

    Elle, Morten; Jensen, Marina Bergen

    An improvement in water infrastructure and cleaning up the waters changed many harbour cities in Denmark at the beginning of the 90s. The harbour cities changed from drity, run-down industrial harbours to clean and attractive harbour dwelling creating new city centres and vital city areas...

  13. [Prevalence of antibodies to hepatitis A virus in healthcare workers and associated variables].

    Science.gov (United States)

    Carreras-Valls, Rosa; Valverde-Lozano, Judit; Benito-Carreras, Dolors; Inglés-Torruella, Joan; Vilardell-Ynaraja, Miquel; Garre-Olmo, Josep; Gil-Soto, Rosa; Escalé-Roca, Margarita

    2013-01-01

    Vaccination against hepatitis A is recommended in risk groups, including healthcare workers. The objective of this study was to determine the prevalence of antibodies to HAV (IgG) among workers in the healthcare setting in order to establish criteria for vaccination. A cross-sectional, analytic, observational study of 4,864 employees was undertaken in four healthcare companies in Catalonia (Spain). The variables gathered included personal data, professional category, location of employment, and serology. The overall prevalence of antibodies to HAV was 52.7%. The prevalence significantly increased with greater age. The mean age of seropositive workers was 41.5 years compared with 34.3 in workers with negative serology. The highest prevalence of antibodies was found in cleaning employees (74.2%) and catering staff (75.3%). Given the high prevalence of seronegative adults susceptible to infection and the characteristics of their professional activities, vaccination of all staff working in health institutions should be considered. Copyright © 2012 SESPAS. Published by Elsevier Espana. All rights reserved.

  14. Economic and environmental impacts of proposed changes to Clean Water Act thermal discharge requirements

    International Nuclear Information System (INIS)

    Veil, J.A.

    1994-01-01

    This paper examines the economic and environmental impact to the power industry of limiting thermal mixing zones to 1000 feet and eliminating the Clean Water Act section 316(a) variance. Power companies were asked what they would do if these two conditions were imposed. Most affected plants would retrofit cooling towers and some would retrofit diffusers. Assuming that all affected plants would proportionally follow the same options as the surveyed plants, the estimated capital cost of retrofitting cooling towers or diffusers at all affected plants exceeds $20 billion. Since both cooling towers and diffusers exert an energy penalty on a plant's output, the power companies must generate additional power. The estimated cost of the additional power exceeds $10 billion over 20 years. Generation of the extra power would emit over 8 million tons per year of additional carbon dioxide. Operation of the new cooling towers would cause more than 1.5 million gallons per minute of additional evaporation

  15. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  16. Clean water, clean hands or new vaccines?

    Science.gov (United States)

    Luby, Stephen P

    2017-06-01

    Throughout human history, pathogens transmitted through feces from person to person have caused substantial mortality. Over a century ago civil engineers in high income countries developed approaches to collect and remove feces from the environment that in communities with high incomes and strong governments markedly reduced the burden of enteric disease. These approaches, however, have not been successfully extended to impoverished communities in low income countries. Water/sanitation/hygiene professionals have attempted, with only limited success, to reduce fecal exposure and human disease in the absence of definitive civil engineering approaches. Medical professionals have worked to develop vaccines against some of the most important fecal oral pathogens. Each of these approaches needs further development and adaptation to optimally address the burden of fecally transmitted diseases in impoverished communities. © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  17. Perceptions of Water Ownership, Water Management, and the Responsibility of Providing Clean Water

    Directory of Open Access Journals (Sweden)

    Jacqueline Noga

    2013-11-01

    Full Text Available Perceptions of water and water related issues still render many under-researched topics. This study aims to further our knowledge regarding people’s perceptions of water and our understanding about the different ways individuals use water. The authors asked the question: Does the way an individual perceives water (i.e., as a commodity, a human right, private resource, public resource and/or natural resource influence consumption and conservation of water, and sentiments towards control and allocation of water? An exploratory online questionnaire was designed to generate qualitative and quantitative data of survey participants’ perceptions, beliefs and actions towards water issues, such as overconsumption and scarcity. Data analysis included comparison of the quantitative data regarding the non-statistical association between how an individual perceives water and the individual’s beliefs, as well as qualitative analysis of the comments using an iterative pattern coding technique. One hundred and sixty four individuals participated in the survey (75% completion rate and over 430 comments were made. Themes that emerged from the comments included: responsibility, scarcity, the value of water, knowledge gained and education needed. Comparison of the different perceptions of water revealed that different perceptions of what water is resulted in different beliefs about what the cost of water should be. These findings have implications for future water use, including what needs to change in order to increase appreciation for water issues.

  18. Re-establishing clean water in a disaster.

    Science.gov (United States)

    Fournier, Chris

    2011-09-01

    When a disaster occurs, water systems can be overwhelmed with sediment, chemicals, microbes, and other harmful organisms. Dialysis clinics need to have disaster management plans and protocols in place to meet the demands of any situation. During emergency events, such as large widespread natural disasters, it is necessary to have the support of outside resources to keep the clinic operating or to aid in returning it to service as quickly and as safely as possible. Before proceeding with any medical treatments that use water, such as dialysis, facilities should address five different response actions to establish the safety and effectiveness of their water system. Test the water quality prior to treating patients. Make sure the system is working properly by performing critical water tests. Compare all results with pre-disaster data to help spot any warning signs. Inspect the water system, including all connections, timers, and settings. Consider contacting your water treatment vendor for additional verification and support. Be sure to closely monitor the water system equipment; make sure it is not overwhelmed by staying in touch with local water authorities. They may "shock" their distribution system to regain compliance. Make every effort to conserve water during this time. Change the water system. If the central water system has been compromised, consider using portable RO units or portable exchange DI tanks. Finally, moving your patients to another facility may be the only alternative, so work with other local facilities unaffected by the disaster.

  19. Controle automático do fluxo de água na etapa de limpeza em unidades de beneficiamento de tomate de mesa Automatic control of water sistems in the cleaning step in fresh market tomato packing units

    Directory of Open Access Journals (Sweden)

    Marcos D. Ferreira

    2011-10-01

    Full Text Available A água é um recurso cada vez mais escasso e também de alto custo em várias regiões. O beneficiamento de frutas e hortaliças, em geral, apresenta elevado consumo de água durante o processo de limpeza. A linha de beneficiamento e de classificação do tomate de mesa é constituída de: recebimento, limpeza, seleção, classificação e embalagem. Normalmente, o recebimento dos tomates em uma linha de beneficiamento ocorre com taxa de alimentação constante, porém com interrupções frequentes dos operadores, ocasionando desperdício de energia e água, e a eficiência de limpeza dos frutos. O objetivo deste trabalho foi avaliar um sistema de limpeza dos frutos, equipado com um controle automático de fluxo de água, visando ao uso racional de água. Para a avaliação da eficiência do processo de limpeza, aplicou-se uma metodologia que utiliza o turbidímetro. Observou-se que o índice de limpeza foi, segundo critérios estatísticos, semelhante nos sistemas automatizado e tradicional, todavia o consumo de água no sistema automatizado foi quatro vezes inferior quando comparado ao sistema tradicional, indicando o potencial de aplicação comercial deste sistema.Water is a natural resource becoming scarce in many regions. Cleaning fruits and vegetables, generally demands high water consumption. A fresh market tomato packing-line is composed of: receiving, cleaning, sorting, classifying and packing. Normally, the receiving process for tomatoes in a packing line happens in a constant flow, however often interruptions of operators cause loss of water, energy and also fruits cleaning efficiency. The main goal of this study was to develop an automation system for cleaning fruits, with a rational water use. For evaluating cleaning efficiency it was developed a methodology using a turbidimiter. The results showed that the cleaning efficiency index was statistically similar between the two systems; however, water consumption for the automated

  20. Aerosol challenges to air cleaning systems during severe accidents in nuclear plants

    International Nuclear Information System (INIS)

    Gieseke, J.A.

    1985-01-01

    A variety of air cleaning systems may be operating in nuclear power plants and under severe accident conditions, these systems may be treating airborne concentrations of aerosols which are very high. Predictions of airborne aerosol concentrations in nuclear power plant containments under severe accident conditions are reviewed to provide a basis for evaluating the potential effects on the air cleaning systems. The air cleaning systems include filters, absorber beds, sprays, water pools, ice beds, and condensers. Not all of these were intended to operate as air cleaners but will in fact be good aerosol collectors. Knowledge of expected airborne concentrations will allow better evaluation of system performances

  1. Clean Hands for Life: results of a large, multicentre, multifaceted, social marketing hand-hygiene campaign.

    Science.gov (United States)

    Forrester, L A; Bryce, E A; Mediaa, A K

    2010-03-01

    A year-long multifaceted hand-hygiene campaign entitled Clean Hands for Life targeting individual, environmental and organisational factors that influence healthcare worker (HCW) hand-hygiene behaviour was implemented in 36 acute and long-term care facilities in Vancouver Coastal Health region. The campaign involved rotation of ten novel posters, two poster contests, and distribution of multiple promotional items. A social marketing approach was used to implement and monitor the effectiveness of the campaign. Evaluation included quality assurance surveys, staff surveys (baseline, mid- and post-campaign), and focus groups. A total of 141 poster contest submissions was received, 5452 staff surveys completed and 14 focus groups conducted. Overall knowledge of the importance of hand-hygiene and intention to clean hands was high at baseline. No significant differences were observed when mid- and post-campaign scores were compared to baseline. The majority (89.5%) of HCWs reported that they preferred soap and water over alcohol hand gel. A significant increase in the self-reported use of hand-hygiene products was observed particularly among HCWs not providing direct patient care. Barriers to hand-hygiene included inappropriate placement of sinks, traffic flow issues, inadequately stocked washrooms, workload and time constraints. Organisational support was visible throughout the campaign. The results showed that social marketing is an effective approach in engaging HCWs. Hand-hygiene campaigns that focus almost exclusively on increasing awareness among HCWs may not be as successful as multifaceted campaigns or campaigns that target identified barriers to hand-hygiene. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Water Quality Assessment of Selected Domestic Water Sources

    African Journals Online (AJOL)

    Nwokem et al.

    @yahoo.com ... were collected in clean sterilized plastic bottles in the rainy ... centers often depend on the water vendors for domestic water supply ... MATERIALS AND METHODS .... water balance problems for individual aquatic organisms.

  3. Clean coal technologies

    International Nuclear Information System (INIS)

    Aslanyan, G.S.

    1993-01-01

    According to the World Energy Council (WEC), at the beginning of the next century three main energy sources - coal, nuclear power and oil will have equal share in the world's total energy supply. This forecast is also valid for the USSR which possesses more than 40% of the world's coal resources and continuously increases its coal production (more than 700 million tons of coal are processed annually in the USSR). The stringent environmental regulations, coupled with the tendency to increase the use of coal are the reasons for developing different concepts for clean coal utilization. In this paper, the potential efficiency and environmental performance of different clean coal production cycles are considered, including technologies for coal clean-up at the pre-combustion stage, advanced clean combustion methods and flue gas cleaning systems. Integrated systems, such as combined gas-steam cycle and the pressurized fluidized bed boiler combined cycle, are also discussed. The Soviet National R and D program is studying new methods for coal utilization with high environmental performance. In this context, some basic research activities in the field of clean coal technology in the USSR are considered. Development of an efficient vortex combustor, a pressurized fluidized bed gasifier, advanced gas cleaning methods based on E-beam irradiation and plasma discharge, as well as new catalytic system, are are presented. In addition, implementation of technological innovations for retrofitting and re powering of existing power plants is discussed. (author)

  4. Effectiveness of deep cleaning followed by hydrogen peroxide decontamination during high Clostridium difficile infection incidence.

    Science.gov (United States)

    Best, E L; Parnell, P; Thirkell, G; Verity, P; Copland, M; Else, P; Denton, M; Hobson, R P; Wilcox, M H

    2014-05-01

    Clostridium difficile infection (CDI) remains an infection control challenge, especially when environmental spore contamination and suboptimal cleaning may increase transmission risk. To substantiate the long-term effectiveness throughout a stroke rehabilitation unit (SRU) of deep cleaning and hydrogen peroxide decontamination (HPD), following a high incidence of CDI. Extensive environmental sampling (342 sites on each occasion) for C. difficile using sponge wipes was performed: before and after deep cleaning with detergent/chlorine agent; immediately following HPD; and on two further occasions, 19 days and 20 weeks following HPD. C. difficile isolates underwent polymerase chain reaction ribotyping and multi-locus variable repeat analysis (MLVA). C. difficile was recovered from 10.8%, 6.1%, 0.9%, 0% and 3.5% of sites at baseline, following deep cleaning, immediately after HPD, and 19 days and 20 weeks after HPD, respectively. C. difficile ribotypes recovered after deep cleaning matched those from CDI cases in the SRU during the previous 10 months. Similarly, 10/12 of the positive sites identified at 20 weeks post-HPD harboured the same C. difficile ribotype (002) and MLVA pattern as the isolate from the first post-HPD CDI case. CDI incidence [number of cases on SRU per 10 months (January-October 2011)] declined from 20 before to seven after the intervention. HPD, after deep cleaning with a detergent/chlorine agent, was highly effective for removing environmental C. difficile contamination. Long-term follow-up demonstrated that a CDI symptomatic patient can rapidly recontaminate the immediate environment. Determining a role for HPD should include long-term cost-effectiveness evaluations. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. Waste cleaning using CO2-acid microemulsion

    International Nuclear Information System (INIS)

    Park, Kwangheon; Sung, Jinhyun; Koh, Moonsung; Ju, Minsu

    2011-01-01

    Frequently we need to decontaminate radioactive wastes for volume reduction purposes. Metallic contaminants in wastes can be removed by dissolution to acid; however, this process produces a large amount of liquid acid waste. To reduce this 2ndary liquid waste, we suggest CO 2 -acid emulsion in removing metallic contaminants. Micro- and macro-emulsion of acid in liquid/supercritical CO 2 were successfully made. The formation region of microemulsion (water or acid in CO 2 ) was measured, and stability of the microemulsion was analyzed with respect to surfactant types. We applied micro- and macro-emulsion containing acid to the decontamination of radioactive metallic parts contaminated on the surface. The cleaning methods of micro- and macro-emulsion seemed better compared to the conventional acid cleaning. Moreover, these methods produce very small amount of secondary wastes. (author)

  6. Cleaning of spent solvent and method of processing cleaning liquid waste

    International Nuclear Information System (INIS)

    Ozawa, Masaki; Kawada, Tomio; Tamura, Nobuhiko.

    1993-01-01

    Spent solvents discharged from a solvent extracting step mainly comprise n-dodecane and TBP and contain nuclear fission products and solvent degradation products. The spent solvents are cleaned by using a sodium chloride free detergent comprising hydrazine oxalate and hydrazine carbonate in a solvent cleaning device. Nitric acid is added to the cleaning liquid wastes containing spent detergents extracted from the solvent cleaning device, to control an acid concentration. The detergent liquid wastes of controlled acid concentration are sent to an electrolysis oxidation bath as electrolytes and electrochemically decomposed in carbonic acid gas, nitrogen gas and hydrogen gas. The decomposed gases are processed as off gases. The decomposed liquid wastes are processed as a waste nitric acid solution. This can provide more effective cleaning. In addition, the spent detergent can be easily decomposed in a room temperature region. Accordingly, the amount of wastes can be decreased. (I.N.)

  7. Laser cleaning of 19th century Congo rattan mats

    International Nuclear Information System (INIS)

    Carmona, N.; Oujja, M.; Roemich, H.; Castillejo, M.

    2011-01-01

    There is a growing interest by art conservators for laser cleaning of organic materials, such as wooden artworks, paper and textiles, since traditional cleaning with solvents can be a source of further decay and mechanical cleaning may be too abrasive for sensitive fibers. In this work we present a successful laser cleaning approach for 19th century rattan mats from the Brooklyn Museum collection of African Art, now part of the study collection at the Conservation Center in New York. Tests were carried out using the fundamental (1064 nm) and second harmonic (532 nm) wavelength of a Q-switched Nd:YAG laser to measure threshold values both for surface damage and color changes for different types of rattan samples. The irradiated substrates were investigated by optical microscopy, scanning electron microscopy and by UV-vis spectroscopy in order to determine the efficiency of laser cleaning and to assess possible deterioration effects that may have occurred as a result of laser irradiation. The study showed that by using the laser emission at 532 nm, a wavelength for which photon energy is below the bond dissociation level of the main cellulosic compounds and the water absorption is negligible, it is possible to select a range of laser fluences to remove the black dust layer without damaging the rattan material.

  8. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, P., E-mail: mportcal@upo.es [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain); Antúnez, V.; Ortiz, R.; Martín, J.M. [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain); Gómez, M.A. [Instituto Andaluz de Patrimonio Histórico, Camino de los Descubrimientos s/n, 41092 Seville (Spain); Hortal, A.R.; Martínez-Haya, B. [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain)

    2013-10-15

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  9. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    International Nuclear Information System (INIS)

    Ortiz, P.; Antúnez, V.; Ortiz, R.; Martín, J.M.; Gómez, M.A.; Hortal, A.R.; Martínez-Haya, B.

    2013-01-01

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  10. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    Science.gov (United States)

    Ortiz, P.; Antúnez, V.; Ortiz, R.; Martín, J. M.; Gómez, M. A.; Hortal, A. R.; Martínez-Haya, B.

    2013-10-01

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  11. Self-cleaning Foliar Surfaces Characterization using RIMAPS Technique and Variogram Method

    International Nuclear Information System (INIS)

    Rosi, Pablo E.

    2002-01-01

    Along the last ten years many important studies about characterization of self-cleaning foliar surfaces have been done and focused new interest on this kind of surfaces.These studies were possible due to the development of a novel preparation technique for this biological material that let us observe the delicate structures of a foliar surface under scanning electron microscope (S.E.M.).This technique consists of replacing the natural water of the specimen by glycerol. Digital S.E.M. images from both self-cleaning and non-self-cleaning foliar surfaces were obtained and analyzed using RIMAPS technique and Variograms method. Our results revealed the existence of a common and exclusive geometrical pattern that is found in species which present self-cleaning foliar surfaces.This pattern combines at least nine different directions.The results from the Variograms method showed that the stomata play a key role in the determination of foliar surface roughness. In addition, spectra from RIMAPS technique constitute a fingerprint of a foliar surface so they can be used to find evolutionary relationships among species.Further studies will provide more detailed information to fully elucidate the self-cleaning pattern, so it might be possible to reproduce it on an artificial surface and make it self-cleaning

  12. Is dry cleaning all wet?

    International Nuclear Information System (INIS)

    Ryan, M.

    1993-01-01

    Chemical solvents from dry cleaning, particularly perchloroethylene (perc), have contributed to groundwater contamination, significant levels of air pollution in and around cleaners, and chemical accumulation in food. Questions are being raised about the process of cleaning clothes with chemical, and other less toxic cleaning methods are being explored. The EPA has focused attention on the 50 year old Friedburg method of cleaning, Ecoclean, which uses no dangerous chemicals and achieves comparable results. Unfortunately, the cleaning industry is resistant to change, so cutting back on amount of clothes that need dry cleaning and making sure labels aren't exaggerating when they say dry clean only, is frequently the only consumer option now

  13. Cleaning of a copper matte smelting slag from a water-jacket furnace by direct reduction of heavy metals.

    Science.gov (United States)

    Maweja, Kasonde; Mukongo, Tshikele; Mutombo, Ilunga

    2009-05-30

    Cleaning experiments of a copper matte smelting slag from the water-jacket furnace was undertaken by direct reduction in a laboratory-scale electric furnace. The effects of coal-to-slag ratio, w, and the reduction time, t, were considered for two different coal/slag mixing procedures. In the first procedure, metallurgical coal was added to the molten slag, whereas in the second procedure, coal was premixed with the solid slag before charging into the furnace. The recovery of heavy metals (Cu, Co), and the fuming of Pb and Zn were investigated. Contamination of the metal phase by iron and the acidity index of the final slag were analysed as these may impede the economical viability of the process. The lower w value of 2.56% yielded a recovery rate of less than 60% for copper and less than 50% for cobalt, and around 70% for zinc. However, increasing w to 5% allowed the recovery of 70-90% for Cu, Co and Zn simultaneously after 30-60 min reduction of the molten slag. After reduction, the cleaned slags contained only small amounts of copper and cobalt (zinc was efficient as the %Pb of the residual slag dropped to levels lower than 0.04% after 30 min of reduction. Ninety percent of the lead was removed from the initial slag and collected in the dusts. The zinc content of the cleaned slags quickly dropped to between 1 and 3 wt% from the initial 8.2% after 30 min reduction for w value of 5 and after 60 min reduction for w value of 2.56. The dusts contained about 60% Zn and 10% Pb. Recovery of lead from fuming of the slag was higher than 90% in all the experimental conditions considered in this study.

  14. Plasma cleaning for waste minimization

    Energy Technology Data Exchange (ETDEWEB)

    Ward, P.P.

    1993-07-01

    Although plasma cleaning is a recognized substitute for solvent cleaning in removing organic contaminants, some universal problems in plasma cleaning processes prevent wider use of plasma techniques. Lack of understanding of the fundamental mechanisms of the process, unreliable endpoint detection techniques, and slow process times make plasma cleaning processes less than desirable. Our approach to address these plasma cleaning problems is described. A comparison of plasma cleaning rates of oxygen and oxygen/sulfur hexafluoride gases shows that fluorine-containing plasmas can enhance etch rates by 400% over oxygen alone. A discussion of various endpoint indication techniques is discussed and compared for application suitability. Work toward a plasma cleaning database is discussed. In addition to the global problems of plasma cleaning, an experiment where the specific mixed-waste problem of removal of machine oils from radioactive scrap metal is discussed.

  15. WINDOW-CLEANING

    CERN Multimedia

    Environmental Section / ST-TFM

    2001-01-01

    The two-month window-cleaning session on the Meyrin, Prévessin and LEP sites will soon begin. The cleaning contractors will work from Monday to Saturday, every week from 4.00 a.m. to 8.00 p.m. The work will be organised so as to disturb users as little as possible. In any event, a work notice will be left in each office 24 hours beforehand. To prevent any damage to documents or items which could occur despite the precautions taken, please clear completely the window-sills and the area immediately around them. If, however, for valid reasons, the work cannot be done on the scheduled day, please inform the Environmental Section by telephoning: 73753 / 74233 / 72242 If you are going to be absent during this two-month period, we should be grateful if you would clear the above mentioned areas before your departure. REMINDER To allow more thorough cleaning of the entrance doors to buildings and also facilitate the weekly work of the cleaning contractors, we ask you to make use of the notice boards at the...

  16. Flux recovery of ceramic tubular membranes fouled with whey proteins: Some aspects of membrane cleaning

    Directory of Open Access Journals (Sweden)

    Popović Svetlana S.

    2008-01-01

    Full Text Available Efficiency of membrane processes is greatly affected by the flux reduction due to the deposits formation at the surface and/or in the pores of the membrane. Efficiency of membrane processes is affected by cleaning procedure applied to regenerate flux. In this work, flux recovery of ceramic tubular membranes with 50 and 200 nm pore size was investigated. The membranes were fouled with reconstituted whey solution for 1 hour. After that, the membranes were rinsed with clean water and then cleaned with sodium hydroxide solutions or formulated detergents (combination of P3 Ultrasil 67 and P3 Ultrasil 69. Flux recovery after the rinsing step was not satisfactory although fouling resistance reduction was significant so that chemical cleaning was necessary. In the case of 50 nm membrane total flux recovery was achieved after cleaning with 1.0% (w/w sodium hydroxide solution. In the case of 200 nm membrane total flux recovery was not achieved irrespective of the cleaning agent choice and concentration. Cleaning with commercial detergent was less efficient than cleaning with the sodium hydroxide solution.

  17. Removal of waterborne pathogens from liver transplant unit water taps in prevention of healthcare-associated infections: a proposal for a cost-effective, proactive infection control strategy.

    Science.gov (United States)

    Zhou, Z Y; Hu, B J; Qin, L; Lin, Y E; Watanabe, H; Zhou, Q; Gao, X D

    2014-04-01

    Hospital water supplies often contain waterborne pathogens, which can become a reservoir for healthcare-associated infections (HAIs). We surveyed the extent of waterborne pathogen contamination in the water supply of a Liver Transplant Unit. The efficacy of point-of-use (POU) water filters was evaluated by comparative analysis in routine clinical use. Our baseline environmental surveillance showed that Legionella spp. (28%, 38/136), Pseudomonas aeruginosa (8%, 11/136), Mycobacterium spp. (87%, 118/136) and filamentous fungi (50%, 68/136) were isolated from the tap water of the Liver Transplant Unit. 28.9% of Legionella spp.-positive water samples (n = 38) showed high-level Legionella contamination (≥10(3) CFU/L). After installation of the POU water filter, none of these pathogens were found in the POU filtered water samples. Furthermore, colonizations/infections with Gram-negative bacteria determined from patient specimens were reduced by 47% during this period, even if only 27% (3/11) of the distal sites were installed with POU water filters. In conclusion, the presence of waterborne pathogens was common in the water supply of our Liver Transplant Unit. POU water filters effectively eradicated these pathogens from the water supply. Concomitantly, healthcare-associated colonization/infections declined after the POU filters were installed, indicating their potential benefit in reducing waterborne HAIs. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  18. Modeling, investigation and formulation of hydrophobic coatings for potential self-cleaning applications

    Science.gov (United States)

    Rios, Pablo Fabian

    Self-cleaning surfaces have received a great deal of attention, both in research and commercial applications. Transparent and non-transparent self-cleaning surfaces are highly desired. The Lotus flower is a symbol of purity in Asian cultures, even when rising from muddy waters it stays clean and untouched by dirt. The Lotus leaf "self-cleaning" surface is hydrophobic and rough, showing a two-layer morphology. While hydrophobicity produces a high contact angle, surface morphology reduces the adhesion of dirt and water to the surface, thus water drops slide easily across the leaf carrying the dirt particles with them. Nature example in the Lotus-effect and extensive scientific research on related fields have rooted wide acceptance that high hydrophobicity can be obtained only by a proper combination of surface chemistry and roughness. Most researchers relate hydrophobicity to a high contact angle. However, the contact angle is not the only parameter that defines liquid-solid interactions. An additional parameter, the sliding angle, related to the adhesion between the liquid drop and the solid surface is also important in cases where liquid sliding is involved, such as self-cleaning applications. In this work, it is postulated that wetting which is related to the contact angle, and interfacial adhesion, which is related to the sliding angle, are interdependent phenomena and have to be considered simultaneously. A variety of models that relate the sliding angle to forces developed along the contact line between a liquid drop and a solid surface have been proposed in the literature. A new model is proposed here that quantifies the drop sliding phenomenon, based also on the interfacial adhesion across the contact area of the liquid/solid interface. The effects of roughness and chemical composition on the contact and sliding angles of hydrophobic smooth and rough surfaces were studied theoretically and experimentally. The validity of the proposed model was investigated

  19. Disposal and handling of nuclear steam generator chemical cleaning wastes

    International Nuclear Information System (INIS)

    Larrick, A.P.; Schneidmiller, D.

    1978-01-01

    A large number of pressurized water nuclear reactor electrical generating plants have experienced a corrosion-related problem with their steam generators known as denting. Denting is a mechanical deformation of the steam generator tubes that occurs at the tube support plates. Corrosion of the tube support plates occurs within the annuli through which the tubes pass and the resulting corrosion oxides, which are larger in volume than the original metal, compress and deform the tubes. In some cases, the induced stresses have been severe enough to cause tube and/or support cracking. The problem was so severe at the Turkey Point and Surrey plants that the tubing is being replaced. For less severe cases, chemical cleaning of the oxides, and other materials which deposit in the annuli from the water, is being considered. A Department of Energy-sponsored program was conducted by Consolidated Edison Co. of New York which identified several suitable cleaning solvents and led to in-plant chemical cleaning pilot demonstrations in the Indian Point Unit 1 steam generators. Current programs to improve the technology are being conducted by the Electric Power Research Institute, and the three PWR NSSS vendors with the assistance of numerous consultants, vendors, and laboratories. These programs are expected to result in more effective, less corrosive solvents. However, after a chemical cleaning is conducted, a large problem still remains- that of disposing of the spent wastes. The paper summarizes some of the methods currently available for handling and disposal of the wastes

  20. Mechanics ofadhesion and contact self-cleaning of bio-inspired microfiberadhesives

    Science.gov (United States)

    Abusomwan, Uyiosa Anthony

    The remarkable attachment system of geckos has inspired the development of dry microfiber adhesives through the last two decades. Some of the notable characteristics of gecko-inspired fibrillar adhesives include: strong, directional, and controllable adhesion to smooth and rough surfaces in air, vacuum, and under water; ability to maintain strong adhesion during repeated use; anti-fouling and self-cleaning after contamination. Given these outstanding qualities, fibrillar adhesives promise an extensive range of use in industrial, robotic, manufacturing, medical, and consumer products. Significant advancements have been made in the design of geckoinspired microfiber adhesives with the characteristic properties listed above, with the exception of the anti-fouling and self-cleaning features. The self-cleaning mechanism of the gecko's adhesion system plays an important role to its ability to remain sticky in various environments. Similarly, enabling self-cleaning capability for synthetic microfiber adhesives will lead to robust performance in various areas of application. Presently, the practical use of fibrillar adhesives is restricted mainly to clean environments, where they are free from contaminants. The goal of this thesis is to conduct a detailed study of the mechanisms and mechanics of contact-based self-cleaning of gecko-inspired microfiber adhesives. This work focuses on contact self-cleaning mechanisms, as a more practical approach to cleaning. Previous studies on the cleaning of microfiber adhesives have mostly focused on mechanisms that involve complete removal of the contaminants from the adhesive. In this thesis, a second cleaning process is proposed whereby particles are removed from the tip of the microfibers and embedded between adjacent microfibers or in grooves patterned onto the adhesive, where they are no longer detrimental to the performance of the adhesive. In this work, a model of adhesion for microfiber adhesives that take the deformation of the

  1. Automated cleaning of electronic components

    International Nuclear Information System (INIS)

    Drotning, W.; Meirans, L.; Wapman, W.; Hwang, Y.; Koenig, L.; Petterson, B.

    1994-01-01

    Environmental and operator safety concerns are leading to the elimination of trichloroethylene and chlorofluorocarbon solvents in cleaning processes that remove rosin flux, organic and inorganic contamination, and particulates from electronic components. Present processes depend heavily on these solvents for manual spray cleaning of small components and subassemblies. Use of alternative solvent systems can lead to longer processing times and reduced quality. Automated spray cleaning can improve the quality of the cleaning process, thus enabling the productive use of environmentally conscious materials, while minimizing personnel exposure to hazardous materials. We describe the development of a prototype robotic system for cleaning electronic components in a spray cleaning workcell. An important feature of the prototype system is the capability to generate the robot paths and motions automatically from the CAD models of the part to be cleaned, and to embed cleaning process knowledge into the automatically programmed operations

  2. Fouling research and cleaning effect by sponge ball on condencer tubes

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, S; Sano, A [Kansai Electric Power Co., Inc., Osaka (Japan); Minamoto, K; Mimura, K; Kyohara, S

    1978-07-01

    Systematic research has been performed to investigate the cleaning effect on condensers cooled by sea water. The test has been done for a year using the test condenser at the Kainan Power Station, Kansai Electric Power Company. The main purpose of this research was to see the effect of cleaning inner walls of condenser tubes with sponge balls on the prevention of adhesion of marine creatures such as barnacles and other shellfishes. As the test tubes, the aluminum-brass and titanium tubes with 25.4 mm diameter, 1.245 mm thickness and 170 mm length were used. Frequency of cleaning and flow rate were chosen as the variable parameters. The effect of seasons was also investigated. Major conclusions drawn from this research were as follows. (1) More adhesion of barnacles was observed at slower flow speed and in titanium tubes rather than aluminum brass tubes. (2) At the flow speed of 1 m/sec. cleaning frequency of more than twice a week was necessary to perfectly avoid the adhesion. (3) In summer, the adhesion was most intensive, whereas in winter, it was the least. (4) Barnacles were the most predominant organism. (5) Cleaning with sponge balls was effective.

  3. Recent developments in the Clean Water Act: Section 404 regulatory program

    Energy Technology Data Exchange (ETDEWEB)

    Kelsch, T. (EPA, Washington, DC (United States))

    1992-12-01

    Since the late 1970's and the 1980's, the Nation has become increasingly aware of the vital role wetlands play in providing habitat, protecting us from flooding and maintaining surface water quality. This public awakening came at the same time that the Fish and Wildlife Service's National Wetlands Inventory published reports indicating that less than one half of the wetlands that existed when the Europeans came to the US remain. The reports also indicated that the US was continuing to lose approximately 450,000 acres of our wetlands per year. Although recent data updating the status and trends of wetland losses for the 1980's indicate that the rate of loss has decreased, the Fish and Wildlife Service estimates indicate that approximately 290,000 acres of wetlands are still lost each year. Any loss in the natural functions provided by wetlands is not just felt in the environment; we simultaneously sustain, as a loss to our national economy, a decline in the income that could have been derived from the fisheries, recreation and other critical services performed by wetland systems. Clearly wetlands merit protection. However, in the US, where over 75 percent of our remaining wetlands are on private property, the protection of wetlands is often a difficult and sometimes contentious issue -- evoking debate about private property rights, economic development, the public interest in protecting wetland values, and the kind of world we wish to leave for future generations. Section 404 of the Clean Water Act establishes the primary Federal regulatory program providing protection for the Nation's remaining wetlands. The Section 404 permit program is recognized by both its supporters and critics as one of the strongest, yet often most contentious, Federal environmental protection programs. This presentation provides an overview of the Section 404 regulatory requirements and discusses some of the recent developments that have stirred considerable

  4. Effects of micro- and nano-structures on the self-cleaning behaviour of lotus leaves

    Science.gov (United States)

    Cheng, Y. T.; Rodak, D. E.; Wong, C. A.; Hayden, C. A.

    2006-03-01

    When rain falls on lotus leaves water beads up with a high contact angle. The water drops promptly roll off the leaves, collecting dirt along the way. This self-cleaning ability or lotus effect has, in recent years, stimulated much research effort worldwide for a variety of applications ranging from self-cleaning window glasses, paints, and fabrics to low friction surfaces. What are the mechanisms giving rise to the lotus effect? Although chemical composition and surface structure are believed important, a systematic experimental investigation of their effects is still lacking. By altering the surface structure of the leaves while keeping their chemical composition approximately the same, we report in this study the influence of micro- and nano-scale structures on the wetting behaviour of lotus leaves. The findings of this work may help design self-cleaning surfaces and improve our understanding of wetting mechanisms.

  5. Occupational skin diseases in Czech healthcare workers from 1997 to 2009.

    Science.gov (United States)

    Machovcová, A; Fenclová, Z; Pelclová, D

    2013-04-01

    The healthcare sector ranked in second place among economic sectors in the Czech Republic, with about 11.4 % of all occupational diseases in 2009. Skin diseases constituted about 20 % of all occupational diseases. The aim of this study was to analyze the causes and trends in allergic and irritant-induced skin diseases in the healthcare sector. The data concerning occupational skin diseases (Chapter IV of the Czech List of Occupational Diseases, non-infectious skin illnesses) in the healthcare sector were analyzed from the Czech National Registry of Occupational Diseases from 1997 until 2009. The trends in the total counts and most frequent causes were evaluated. During the past 13 years, a total of 545 skin diseases were acknowledged in healthcare workers. Allergic contact dermatitis was diagnosed in 464 (85 %), irritant contact dermatitis in 71 (13 %) and contact urticaria in 10 subjects (2 %). Ninety-five percent of the patients were females. The overall incidence in individual years varied between 1.0 and 2.9 cases per 10,000 full-time employees per year. Disinfectants were the most frequent chemical agents causing more than one third of all allergic skin diseases (38 %), followed by rubber components (32 %) and cleaning agents (10 %). A general downward trend of diagnosed cases of occupational skin diseases in heath care workers in the Czech Republic over the past 13 years was demonstrated.

  6. CLEAN CHEMICAL SYNTHESIS IN WATER

    Science.gov (United States)

    Newer green chemistry approach to accomplish chemical synthesis in water is summarized. Recent global developments pertaining to C-C bond forming reactions using metallic reagents and direct use of the renewable materials such as carbohydrates without derivatization are described...

  7. Comparison of glow discharge cleaning with Taylor-type discharge cleaning on JFT-2

    International Nuclear Information System (INIS)

    Yokokura, Kenji; Matsuzaki, Yoshimi; Tani, Takashi

    1983-01-01

    Method of glow discharge cleaning (GDC) was applied to JFT-2 tokamak and the cleaning effect of GDC was compared with that of taylor-type discharge cleaning (TDC) on the same machin. Results show clearly their individual characteristics to remove light impurities. Their abilities of surface cleaning were compared each other by observing cleanliness of sample surfaces with a AES and by measuring decay times of produced gas pressures during discharge cleanings with a mass-analyser. It was shown that TDC method is better by several times than GDC method from a mass-analyser measurement. Moreover discharge cleaning time necessary to reduce light impurities in the normal plasma to a certain level was compared by monitoring time evolution of radiation loss power with a bolometer, and the time by TDC was only one fifth of that by GDC. The advantage of TDC may come from the excellently high hydrogen flux which interacts with the limiter and the wall. (author)

  8. Environmental Compliance Guide. Guidance manual for Department of Energy compliance with the Clean Water Act: National Pollutant Discharge Elimination System (NPDES)

    Energy Technology Data Exchange (ETDEWEB)

    1982-07-01

    This manual provides general guidance for Department of Energy (DOE) officials for complying with Sect. 402 of the Clean Water Act (CWA) of 1977 and amendments. Section 402 authorizes the US Environmental Protection Agency (EPA) or states with EPA approved programs to issue National Pollutant Discharge Elimination System (NPDES) permits for the direct discharge of waste from a point source into waters of the United States. Although the nature of a project dictates the exact information requirements, every project has similar information requirements on the environmental setting, type of discharge(s), characterization of effluent, and description of operations and wastewater treatment. Additional information requirements for projects with ocean discharges, thermal discharges, and cooling water intakes are discussed. Guidance is provided in this manual on general methods for collecting, analyzing, and presenting information for an NPDES permit application. The NPDES program interacts with many sections of the CWA; therefore, background material on pertinent areas such as effluent limitations, water quality standards, toxic substances, and nonpoint source pollutants is included in this manual. Modifications, variances, and extensions applicable to NPDES permits are also discussed.

  9. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    Science.gov (United States)

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  10. Effect of sponge ball cleaning on removing barnacles in condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Mimura, K; Minamoto, K; Kyohara, S [Kobe Steel Ltd. (Japan)

    1977-07-01

    Considering environmental protection, the recent tendency has been to give up chlorination of cooling water for power stations. The experimental results show that cooling sea-water without chlorination cannot get rid of barnacles which grow inside condenser tubes when the speed of the cooling water is less than 1 m/s. Cleaning by sponge balls 2 -- 3 times a week is found to be effective for both barnacle prevention and inactive film formation on the tube surface.

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... has been rented. This feature is not available right now. Please try again later. Published on May ... 34 How The Clean Hands - Safe Hands System Works - Duration: 3:38. Clean Hands-Safe Hands 5, ...

  12. Clean Water Act (Section 404) and Rivers and Harbors Act (Sections 9 and 10). Environmental Guidance Program Reference Book, Revision 4

    Energy Technology Data Exchange (ETDEWEB)

    None

    1992-03-01

    This Reference Book contains a current copy of the Clean Water Act (Section 404) and the Rivers and Harbors Act (Sections 9 and 10) and those regulations that implement those sections of the statutes and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, IH-231 (FTS 896-2609 or Commercial 202/586-2609).

  13. A viable CDM model for solar water heaters; CDM-Clean Development Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    2008-09-15

    It is a well known fact that solar water Heaters (SWH) replace fossil fuels and they do not represent business as usual scenario. Therefore use of this appliance can qualify to be considered as Clean Development Mechanism (CDM) project. However a single solar water heater is a very small unit to be able to generate sufficient Certified Emission Reductions (CERs) to pursue it as a CDM project. Even if the project is considered at the level of local venders or at the level of a company engaged in manufacturing SWH, the CERs still remain very small. The study examines the size of the project from the perspective of its viability as a CDM project and also explores other related issues such as additionality requirement, selection of methodology, baseline calculations, approach for stakeholders' comments, potential bundlers, monitoring and verification, and required policy interventions. Bank of Maharashtra (BOM), a commercial bank in India engaged in financing Solar Water Heaters (SWH), was considered as the base for the study. The CERs were calculated considering Electricity and LPG as the baseline. For the purpose of sensitivity analysis, various price bands for CERs (between US$ 15-25/CER) were considered. The analysis was carried out with bundling of SWH at BOM level, and at the Association of Banks (AOB) / Ministry level (in which case SWH financed by several banks are bundled). Recently approved Programme of Activities (PoA) approach was also considered in the analysis. The analysis clearly indicated that: 1) The CDM project with bundling at an individual bank level with about 8600 installations, though cash surplus, would generate the cash just to meet its own sustainability. But it is a very small project. 2) Bundling of installations by various banks, through an entity such as Association of Banks, would be a viable and sustainable CDM project due to benefits arising out of scale of economy. 3) The profitability of the CDM project would improve further if

  14. Water Pollution Scrubber Activity Simulates Pollution Control Devices.

    Science.gov (United States)

    Kennedy, Edward C., III; Waggoner, Todd C.

    2003-01-01

    A laboratory activity caused students to think actively about water pollution. The students realized that it would be easier to keep water clean than to remove pollutants. They created a water scrubbing system allowing them to pour water in one end and have it emerge clean at the other end. (JOW)

  15. Clean coal technologies: A business report

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The book contains four sections as follows: (1) Industry trends: US energy supply and demand; The clean coal industry; Opportunities in clean coal technologies; International market for clean coal technologies; and Clean Coal Technology Program, US Energy Department; (2) Environmental policy: Clean Air Act; Midwestern states' coal policy; European Community policy; and R ampersand D in the United Kingdom; (3) Clean coal technologies: Pre-combustion technologies; Combustion technologies; and Post-combustion technologies; (4) Clean coal companies. Separate abstracts have been prepared for several sections or subsections for inclusion on the data base

  16. Financing clean energy market creation. Clean energy ventures, venture capitalists and other investors

    Energy Technology Data Exchange (ETDEWEB)

    Teppo, T. [Helsinki Univ. of Technology, Espoo (Finland). Development and Management in Industry

    2006-07-01

    Many factors have emerged for change towards cleaner and more efficient technologies and services: climate change, increasing oil demands, and rising living standards in many parts of the world are putting an ever-increasing strain on the environment. Recently, these drivers have fueled the formation of a clean energy venture capital market where both independent venture capitalists (VCs) and corporate venture capitalists (CVCs) have invested in clean energy start-ups. Financing of clean energy market creation is the focus of this dissertation. The dissertation contributes to several bodies of literature in the area of entrepreneurship, new industry creation, corporate venturing, and venture capital research. The dissertation uses a grounded theory approach. The study is guided by three data collection approaches with an emphasis on the first two. First, interviews with European and North American VC and CVC firms that have invested in the clean energy sector were carried out. Second, a clean energy venture financing survey that consisted of qualitative, essay-format questions and some quantitative questions was carried out. Third, interviews with clean energy stakeholders were carried out in order to gain a better understanding of the emerging sector. The research results consist of three main findings. First, the research results suggest that clean energy ventures face the following three main entrepreneurial challenges: financing, market education, and growth management. A further study of three clean energy industry categories revealed additional challenges that varied according to the industry development stage. Second, the results demonstrate that, from a venture capitalist perspective, clean energy venture risk characteristics can be divided into two groups: generally recognized risk characteristics and cognitive risk characteristics. The identified generally recognized risk characteristics were market demand and adaptation, incompatibility with the VC model

  17. Chemical cleaning review

    International Nuclear Information System (INIS)

    Dow, B.L.; Thomas, R.C.

    1995-01-01

    Three main chemical processes for cleaning steam generators have evolved from the early work of the industry. Of the more than 50 chemical cleanings carried out to date most have been considered a success by the utilities performing them. (author)

  18. Tube micro-fouling, boiling and steam pressure after chemical cleaning

    International Nuclear Information System (INIS)

    Hu, M.H.

    1998-01-01

    This paper presents steam pressure trends after chemical cleaning of steam generator tubes at four plants. The paper also presents tube fouling factor that serves as an objective parameter to assess tubing boiling conditions for understanding the steam pressure trend. Available water chemistry data helps substantiate the concept of tube micro-fouling, its effect on tubing boiling, and its impact on steam pressure. All four plants experienced a first mode of decreasing steam pressure in the post-cleaning operation. After 3 to 4 months of operation, the decreasing trend stopped for three plants and then restored to a pre-cleaning value or better. The fourth plant is soil in decreasing trend after 12 months of operation. Dissolved chemicals, such as silica, titanium can precipitate on tube surface. The precipitate micro-fouling can deactivate or eliminate boiling nucleation sites. Therefore, the first phase of the post-cleaning operation suffered a decrease in steam pressure or an increase in fouling factor. It appears that micro fouling by magnetite deposit can activate or create more bubble nucleation sites. Therefore, the magnetite deposit micro-fouling results in a decrease in fouling factor, and a recovery in steam pressure. Fully understanding the boiling characteristics of the tubing at brand new, fouled and cleaned conditions requires further study of tubing surface conditions. Such study should include boiling heat transfer tests and scanning electronic microscope examination. (author)

  19. Measuring process performance within healthcare logistics - a decision tool for selecting measuring technologies

    DEFF Research Database (Denmark)

    Feibert, Diana Cordes; Jacobsen, Peter

    2015-01-01

    Performance measurement can support the organization in improving the efficiency and effectiveness of logistical healthcare processes. Selecting the most suitable technologies is important to ensure data validity. A case study of the hospital cleaning process at a public Danish hospital...... was conducted. Monitoring tasks and ascertaining quality of work is difficult in such a process. Based on principal-agent theory, a set of decision indicator has been developed, and a decision framework for assessing technologies to enable performance measurement has been proposed....

  20. Contamination of hospital tap water: the survival and persistence of Pseudomonas aeruginosa on conventional and 'antimicrobial' outlet fittings.

    Science.gov (United States)

    Hutchins, C F; Moore, G; Thompson, K-A; Webb, J; Walker, J T

    2017-10-01

    Pseudomonas aeruginosa infections have been linked to contaminated hospital taps, highlighting the potential for tap outlet fittings (OF) to harbour biofilm. P. aeruginosa may be transferred to OFs via contaminated cleaning cloths. Suggested interventions include flushing regimens and alternative OF designs. To investigate the transfer of P. aeruginosa from a contaminated cleaning cloth to conventional and 'antimicrobial/antibiofilm' OFs and to determine whether this contamination persists and/or leads to contamination of tap water. Microfibre cloths contaminated with P. aeruginosa (10 8  cfu/mL) were used to wipe four different types of OF [one of conventional design (OF-A) and three marketed as 'antimicrobial' and/or 'antibiofilm' (OF- B, -C and -D)]. OFs were inserted into an experimental water distribution system for up to 24 h. Survival was assessed by culture. Single and multiple water samples were collected and cultured for P. aeruginosa. The median number of P. aeruginosa transferred from cloth to OF was 5.7 × 10 5  cfu (OF-A), 1.9 × 10 6  cfu (OF-B), 1.4 × 10 5  cfu (OF-C) and 2.9 × 10 6  cfu (OF-D). Numbers declined on all OFs during the 24 h period with log reductions ranging from 3.5 (OF-C) to 5.2 (OF-B; P > 0.05). All water samples delivered immediately after OF contamination contained P. aeruginosa at ≥10 cfu per 100 mL. Contamination of water delivered from OF-A persisted despite continued flushing. Water delivered from OF-B did not contain P. aeruginosa beyond the first flush. Contaminated cleaning cloths may transfer P. aeruginosa to OFs, leading to contamination of tap water. Although not removing the potential for contamination, 'antimicrobial/antibiofilm' OFs may prevent P. aeruginosa from continually contaminating water delivered from the outlet. Copyright © 2017 The Healthcare Infection Society. All rights reserved.

  1. Steam vacuum cleaning. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. The baseline technology currently used for washing debris is a high-pressure water cleaning (HPWC) system. The system used at the FEMP is the Hotsy reg-sign Model 550B HPWC. Although the HPWC technology has functioned satisfactorily, improvements are being sought in areas related to reduced liquid waste volume, increased productivity, increased washing effectiveness, and decreased airborne contamination. An innovative technology that offers potential improvements in these areas is a steam vacuum cleaning (SVC) system that integrates high-pressure steam cleaning with a vacuum recovery sub-system that simultaneously collects dislodged contaminants thereby reducing airborne contamination. The SVC system selected for demonstration at the FEMP was the Kelly trademark Decontamination System shown. This report provides comparative performance and cost analyses between the Hotsy HPWC system and the Kelly Decontamination System. Both technologies were demonstrated at the FEMP site located at Fernald, Ohio from July 29, 1996 through August 15, 1996. The demonstrations were conducted at the FEMP Plant 1 as part of the LSTD project sponsored by the Deactivation and Decommissioning Focus Area (DDFA) of the US DOE's Office of Science and Technology

  2. Chemical cleaning of UK AGR boilers

    International Nuclear Information System (INIS)

    Rudge, A.; Turner, P.; Ghosh, A.; Clary, W.; Tice, D.

    2002-01-01

    For the first time in their operational lives, UK advanced gas-cooled reactor once-through boilers have been chemically cleaned. Chemical cleaning was necessary to avoid lost output resulting from boiler pressure drops, which had been increasing for a number of years. Chemical cleaning of these boilers presents a number of unique difficulties. These include lack of access to the boilers, highly sensitised 316H superheater sections that cannot be excluded from the cleaning flow path, relatively thin boiler tube walls and an intolerance to boiler tube failure because of the role of the boilers in nuclear decay heat removal. The difficulties were overcome by implementing the clean in a staged manner, starting with an extensive materials testwork programme to select and then to substantiate the cleaning process. The selected process was based on ammoniated citric acid plus formic acid for the principal acid cleaning stage. Materials testwork was followed by an in-plant trial clean of six boiler tubes, further materials testwork and the clean of a boiler tube in a full-scale test rig. An overview is presented of the work that was carried out to demonstrate that the clean could be carried out safely, effectively and without leading to unacceptable corrosion losses. Full-scale chemical cleaning was implemented by using as much of the existing plant as possible. Careful control and monitoring was employed to ensure that the cleaning was implemented according to the specified design, thus ensuring that a safe and effective clean was carried out. Full-scale cleaning has resulted in significant boiler pressure drop recovery, even though the iron burden was relatively low and cleaning was completed in a short time. (orig.)

  3. Effects of exposure to the xenoestrogen octylphenol and subsequent transfer to clean water on liver and gonad ultrastructure during early development of Zoarces viviparus embryos

    DEFF Research Database (Denmark)

    Jespersen, Åse; Rasmussen, Tina H.; Hirche, Majken

    2010-01-01

    ) during exposure and after transfer to clean water (depuration). In the mother fish, significantly higher concentrations of plasma vitellogenin (vtg) and calcium were found in the two exposed groups, when compared with the C group after exposure and depuration. When compared, however, with the respective...

  4. Carbon Dioxide Nucleation as a Novel Cleaning Method for Sodium Alginate Fouling Removal from Reverse Osmosis Membranes desalination

    KAUST Repository

    Alnajjar, Heba

    2017-05-01

    The use of Reverse osmosis (RO) membranes have been significantly increasing in water desalination, and the main operational obstacle in RO desalination plants is membrane fouling. Among other solutes, dissolved biopolymers, such as polysaccharides can lead to severe membrane fouling especially with the addition of calcium ions because of the complexation formation between the surface of membrane and foulants materials. However, this complexation can also take place in the feed bulk, resulting in foulants aggregates formation. Although there are some physical techniques that can maintain the membrane performance without reducing its lifetime, only chemical cleanings are still commonly used in RO plants. In this study, a novel cleaning method is proposed to restore the membrane performance by removing the deposited foulants without reducing the membrane lifetime. The cleaning method is based on using water saturated with dissolved CO2 gas, and its principle is based on producing spontaneous CO2 bubbles due to local pressure difference leading to nucleation of bubbles throughout the membrane surface, especially at nucleation sites, which improve the cleaning efficiency. Alginic acid sodium salt was used as a model of polysaccharides foulants in presence of different concentrations of NaCl and calcium ions aiming to enhance membrane fouling, and then CO2 cleaning solution efficiency, in terms flux recovery (FR), was tested under different operating conditions and compared to other cleaning methods. Average FR of 20%±3, 25%±3 and 80%±3 for MilliQ water, a cleaning solution at pH4, and CO2 solution at 6 bar, 0.17 m/s, and 23 ̊C ±0.2 for 6 minutes were obtained, respectively. The efficiency of this novel cleaning method was also compared to direct osmosis overnight, and the average flux was comparable (about 60%±3), though that the cleaning time was significantly different. Various calcium concentrations (0-10 mM) were added in the alginate solution to study the

  5. Extending CO2 cryogenic aerosol cleaning for advanced optical and EUV mask cleaning

    Science.gov (United States)

    Varghese, Ivin; Bowers, Charles W.; Balooch, Mehdi

    2011-11-01

    Cryogenic CO2 aerosol cleaning being a dry, chemically-inert and residue-free process is used in the production of optical lithography masks. It is an attractive cleaning option for the mask industry to achieve the requirement for removal of all printable soft defects and repair debris down to the 50nm printability specification. In the technique, CO2 clusters are formed by sudden expansion of liquid from high to almost atmospheric pressure through an optimally designed nozzle orifice. They are then directed on to the soft defects or debris for momentum transfer and subsequent damage free removal from the mask substrate. Unlike aggressive acid based wet cleaning, there is no degradation of the mask after processing with CO2, i.e., no critical dimension (CD) change, no transmission/phase losses, or chemical residue that leads to haze formation. Therefore no restriction on number of cleaning cycles is required to be imposed, unlike other cleaning methods. CO2 aerosol cleaning has been implemented for several years as full mask final clean in production environments at several state of the art mask shops. Over the last two years our group reported successful removal of all soft defects without damage to the fragile SRAF features, zero adders (from the cleaning and handling mechanisms) down to a 50nm printability specification. In addition, CO2 aerosol cleaning is being utilized to remove debris from Post-RAVE repair of hard defects in order to achieve the goal of no printable defects. It is expected that CO2 aerosol cleaning can be extended to extreme ultraviolet (EUV) masks. In this paper, we report advances being made in nozzle design qualification for optimum snow properties (size, velocity and flux) using Phase Doppler Anemometry (PDA) technique. In addition the two new areas of focus for CO2 aerosol cleaning i.e. pellicle glue residue removal on optical masks, and ruthenium (Ru) film on EUV masks are presented. Usually, the residue left over after the pellicle

  6. Technology of drill hole and well cleaning for in-situ leaching on the 16th section line ore body

    International Nuclear Information System (INIS)

    Li Xiqi; Liu Jianxiang; Wang Haifeng

    2003-01-01

    The specific feature of the 16th section line ore body of a deposit is deep water table and low confined aquifer. It causes the most trouble for well cleaning during completion and recovering the ore-bearing aquifer to natural state after it is worsened. It is a key point mining the ore body to search for a suitable way for well cleaning at the deep water table

  7. Status of Pesticides and Degradation Products in Soil After Clean up

    African Journals Online (AJOL)

    dell

    The status of pesticide residues in soil samples collected from a former storage site one year after clean-up ... risk to the underground water (Felsot et al. ... the properties of the contaminants, soil .... and isotope ratios for the labelled standards.

  8. What's in Your Water? An Educator's Guide to Water Quality.

    Science.gov (United States)

    Constabile, Kerry, Comp.; Craig, Heidi, Comp.; O'Laughlin, Laura, Comp.; Reiss, Anne Bei, Comp.; Spencer, Liz, Comp.

    This guide provides basic information on the Clean Water Act, watersheds, and testing for water quality, and presents four science lesson plans on water quality. Activities include: (1) "Introduction to Water Quality"; (2) "Chemical Water Quality Testing"; (3) "Biological Water Quality Testing"; and (4) "What Can We Do?" (YDS)

  9. Fouling research and cleaning effect by sponge ball on condencer tubes

    International Nuclear Information System (INIS)

    Matsumoto, Seizo; Sano, Akira; Minamoto, Kenju; Mimura, Keisuke; Kyohara, Shigeru.

    1978-01-01

    Systematic research has been performed to investigate the cleaning effect on condensers cooled by sea water. The test has been done for a year using the test condenser at the Kainan Power Station, Kansai Electric Power Company. The main purpose of this research was to see the effect of cleaning inner walls of condenser tubes with sponge balls on the prevention of adhesion of marine creatures such as barnacles and other shellfishes. As the test tubes, the aluminum-brass and titanium tubes with 25.4 mm diameter, 1.245 mm thickness and 170 mm length were used. Frequency of cleaning and flow rate were chosen as the variable parameters. The effect of seasons was also investigated. Major conclusions drawn from this research were as follows. (1) More adhesion of barnacles was observed at slower flow speed and in titanium tubes rather than aluminum brass tubes. (2) At the flow speed of 1 m/sec. cleaning frequency of more than twice a week was necessary to perfectly avoid the adhesion. (3) In summer, the adhesion was most intensive, whereas in winter, it was the least. (4) Barnacles were the most predominant organism. (5) Cleaning with sponge balls was effective. (Aoki, K.)

  10. Exhaust gas clean up process

    Science.gov (United States)

    Walker, R.J.

    1988-06-16

    A method of cleaning an exhaust gas containing particulates, SO/sub 2/ and NO/sub x/ is described. The method involves prescrubbing with water to remove HCl and most of the particulates, scrubbing with an aqueous absorbent containing a metal chelate and dissolved sulfite salt to remove NO/sub x/ and SO/sub 2/, and regenerating the absorbent solution by controlled heating, electrodialysis and carbonate salt addition. The NO/sub x/ is removed as N/sub 2/ gas or nitrogen sulfonate ions and the oxides of sulfur are removed as a valuable sulfate salt. 4 figs.

  11. Economic Floating Waste Detectionfor Surface Cleaning Robots

    Directory of Open Access Journals (Sweden)

    Sumroengrit Jakkrit

    2017-01-01

    Full Text Available Removing waste out of water surface is a routine task and can be operated by using autonomous surface cleaning robots. This paper presents amethodoflaser-based floating waste detection for surface robot guidance when waste positions are unknown beforehand. Basing on concept of refraction and reflection of laser ray, the proposed laser-based technique is proven to be applicable on floating waste detection. The economic waste detector is constructed and mounted on the robot. Five DOF equations of motion are formulated for calculation of waste position incorporating distance measured by the laser and also the robot motion caused by external wind force as well as water surface tension. Experiments were conducted on a pond with calm water and results show that the presented economic waste detection successfully identify and locate position of plastic bottles floating on water surface within the range of 5 meters.

  12. Waters Edge Land Company, LLC - Clean Water Act Public Notice

    Science.gov (United States)

    The EPA is providing notice of an Administrative Penalty Assessment in the form of an Expedited Storm Water Settlement Agreement against Waters Edge Land Company, LLC, a business located at 10800 Farley St. Overland Park, KS, for alleged violations located

  13. Responsibility for managing healthcare-associated infections: where does the buck stop?

    Science.gov (United States)

    Duerden, B I

    2009-12-01

    The prevention and control of healthcare-associated infections (HCAIs) requires a tripartite partnership between clinicians and carers, managers and government/Department of Health (DoH) across the whole health and social care community. Mandatory surveillance of meticillin-resistant Staphylococcus aureus bacteraemia and Clostridium difficile infection has shown a significant fall from peak numbers in 2003/04 and 2006, respectively, and there is now a zero tolerance approach to preventable infections and poor practice. Success so far has been based on senior management commitment, enhanced real-time surveillance, implementation of clinical protocols (high impact interventions, prudent prescribing), improved hand hygiene and environmental cleaning, and training and audit, backed up by a heightened performance management focus through targets and legislation (Code of Practice). DoH improvement teams have supported National Health Service trusts in implementing change. Responsibility for managing HCAI is a combination of managerial responsibility based upon compliance assurance that procedures and protocols are being implemented and personal professional responsibility of all clinicians and other healthcare workers.

  14. Cleaning and decontamination: Experimental feedback from PHENIX

    International Nuclear Information System (INIS)

    Masse, F.; Rodriguez, G.

    1997-01-01

    After the first few years of operation of PHENIX, it proved necessary to clean, then decontaminate sodium-polluted components, particularly large components such as the intermediate heat exchangers (IHX) and the primary pumps (PP). Ibis document presents the evolution of the cleaning and decontamination processes used, and specifies the reasons for this evolution. As regards the cleaning, experimental feedback and a greater rigour with respect to the hydrogen hazard have resulted in a modification of the process. The new cleaning process used at present (since 1994) is described in greater detail in this document. The main steps are: cold CO 2 bubbling in water, followed by hot CO 2 bubbling, spraying phase, then drying for inspection before immersion. In order to optimize and validate the process, the cleaning and decontamination plant has been highly instrumented, which, in particular, has allowed confirmation of the contention that the major part of the sodium is eliminated during the bubbling phases. With respect to decontamination, the objective is to perfect an efficient process that allows both human intervention with no particular biological shield for repair or maintenance of the components, and requalification of the materials after the decontamination operation. Owing to the high operating temperature of Fast Breeder Reactor components (400 to 550 deg. C), the activated corrosion products deposited on the components melt into the metal. The decontamination process therefore consists in either dissolving the deposits on the surface, or dissolving a thickness of about less than ten micrometers of the base metal. The reference process for austenitic-type steels is the SPm process, which consists in immersing the component in a sulphuric-phosphoric bath (sulphuric acid and phosphoric acid) at a temperature of 60 deg. C for 6 hours. The problem linked to this process is the treatment of the effluents that are produced, particularly phosphate releases. A

  15. Introduction of Small Advertising Cleaning Machine and Its Cleaning Effect Experiments in Beijing%北京市小广告清理设备介绍及清理效果试验

    Institute of Scientific and Technical Information of China (English)

    胡昌夏; 王晓燕; 孙晨阳; 冯伟

    2017-01-01

    对北京市各类小广告清理设备进行了简要介绍,并针对目前广泛使用的移动式小广告清理设备的清理效果进行了试验,在此基础上,对小广告清理设备的选择提出适宜推广使用汽车二类底盘车载小广告清理设备,高压热水清理适应范围最广并且清理效果综合较优,应该作为小广告清理的主要手段.%All kinds of small advertising cleaning machines in Beijing were introduced briefly.Based on the cleaning effect experiment results of small advertising cleaning mobile machines,we offered recornmendatiom on the type selection of the machines that it is suitable for the promotion of the use of two types of chassis car small advertising cleaning equipment;high pressure water cleaning adapts to the widest range and the best comprehensive effect of cleaning,then it should be used as the main means of small advertisements to clean up.

  16. Cleaning lateral morphological features of the root canal: the role of streaming and cavitation.

    Science.gov (United States)

    Robinson, J P; Macedo, R G; Verhaagen, B; Versluis, M; Cooper, P R; van der Sluis, L W M; Walmsley, A D

    2018-01-01

    To investigate the effects of ultrasonic activation file type, lateral canal location and irrigant on the removal of a biofilm-mimicking hydrogel from a fabricated lateral canal. Additionally, the amount of cavitation and streaming was quantified for these parameters. An intracanal sonochemical dosimetry method was used to quantify the cavitation generated by an IrriSafe 25 mm length, size 25 file inside a root canal model filled with filtered degassed/saturated water or three different concentrations of NaOCl. Removal of a hydrogel, demonstrated previously to be an appropriate biofilm mimic, was recorded to measure the lateral canal cleaning rate from two different instruments (IrriSafe 25 mm length, size 25 and K 21 mm length, size 15) activated with a P5 Suprasson (Satelec) at power P8.5 in degassed/saturated water or NaOCl. Removal rates were compared for significant differences using nonparametric Kruskal-Wallis and/or Mann-Whitney U-tests. Streaming was measured using high-speed particle imaging velocimetry at 250 kfps, analysing both the oscillatory and steady flow inside the lateral canals. There was no significant difference in amount of cavitation between tap water and oversaturated water (P = 0.538), although more cavitation was observed than in degassed water. The highest cavitation signal was generated with NaOCl solutions (1.0%, 4.5%, 9.0%) (P streaming. The oscillatory velocities were higher inside the lateral canal 3 mm compared to 6 mm from WL and were higher for NaOCl than for saturated water, which in turn was higher than for degassed water. Measurements of cavitation and acoustic streaming have provided insight into their contribution to cleaning. Significant differences in cleaning, cavitation and streaming were found depending on the file type and size, lateral canal location and irrigant used. In general, the IrriSafe file outperformed the K-file, and NaOCl performed better than the other irrigants tested. The cavitation and

  17. Chemical cleaning of AGR boilers

    International Nuclear Information System (INIS)

    Moore, S.V.; Moore, W.; Rantell, A.

    1978-01-01

    AGR boilers are likely to require post service chemical cleaning to remove accumulated oxides at intervals of 15 - 35 kh. The need to clean will be based on an assessment of such factors as the development of flow imbalances through parallel tubes induced by the formation of rough oxide surfaces, an increasing risk of localised corrosion as the growth of porous oxides proceeds and the risk of tube blockage caused by the exfoliation of steam-grown oxides. The study has shown what heterogeneous multilayer oxides possessing a range of physical and chemical properties form on the alloy steels. They include porous and compact magnetites, chromium spinels and sesquioxide. Ammoniated citric acid has been shown to remove deposited and water-grown magnetites from the carbon and alloy steels but will not necessarily remove the substituted spinels grown on the alloy steels or the potentially spalling steam-grown magnetite on the A1SI 316 superheater. Citric acid supplemented with the reducing agent glyoxal completely removes all oxides from the boiler except the protective inner spinel formed on the 316. Removal of the spinels and compact magnetites occurs more by undercutting and physical detachment than by the dissolution. (author)

  18. Interdental cleaning and gingival injury potential of interdental toothbrushes.

    Science.gov (United States)

    Vogel, Marc; Sener, Beatrice; Roos, M; Attin, Thomas; Schmidlin, Patrick R

    2014-01-01

    The effective cleaning of interdental spaces using toothbrushes is a challenge. The aim of the present in vitro study was to evaluate on the one hand the interdental cleaning efficiency and on the other hand the gingival injury potential of an electric single-headed sonic toothbrush (Water-pik) and two single-tufted manual toothbrushes (Curaprox 1009; Lactona Interdental Brush). Brushes were evaluated using a brushing device. Test dental casts (maxillary sextants) consisting of black teeth coated with white paint were brushed using standardized horizontal movements. Thereafter, black (i.e. cleaned) areas were measured planimetrically. The soft tissue injury potential was evaluated using front segments of porcine mandibles. In the same brushing device, test brushes were moved over the gingiva. Before and after each treatment, the porcine mucosa was stained with a plaque disclosing agent to visualize injured areas, which could then be measured planimetrically as well. These evaluations were each made after 15, 30, 60, and 120 seconds of brushing. The statistical analysis was performed using non-parametric Mann-Whitney tests, and the level of significance was set at 5%. The best cleaning performance of 46% across all interdental spaces assessed was found with the electric sonic toothbrush (Waterpik), while the performances of the manual brushes from Lactona and Curaprox were 14.8% and 5%, respectively. At each point of evaluation, the gingiva was injured most markedly by the powered sonic toothbrush (Waterpik), followed by the manual Curaprox brush. The smallest damage of the porcine gingiva was produced by the manual Lactona brush. When comparing the manual toothbrushes, the Lactona product revealed a better cleaning performance combined with a smaller injury potential than the Curaprox brush. Thus, the prophylactic goal to achieve high degrees of cleaning while producing minimal damage is important and should have priority when evaluating and selecting toothbrushes.

  19. National water summary 1990-91: Hydrologic events and stream water quality

    Science.gov (United States)

    Paulson, Richard W.; Chase, Edith B.; Williams, John S.; Moody, David W.

    1993-01-01

    National Water Summary 1990-91 Hydrologic Events and Stream Water Quality was planned to complement existing Federal-State water-quality reporting to the U.S. Congress that is required by the Clean Water Act of 1972. This act, formally known as the Federal Water Pollution Control Act Amendments of 1972 (Public Law 92-500), and its amendments in 1977,1979,1980,1981,1983, and 1987, is the principal basis for Federal-State cooperation on maintaining and reporting on water quality in the United States. Under section 305(b) of the Clean Water Act, the States must designate uses for waterbodies, biennially assess whether the waterbodies meet designated uses, and report to the U.S. Environmental Protection Agency (EPA), which in turn summarizes the findings of the State assessments in a biennial National Water Quality Inventory report to the Congress.

  20. Cast erosion from the cleaning of debris after the use of a cast trimmer.

    Science.gov (United States)

    Hansen, Paul A; Beatty, Mark W

    2017-02-01

    Whether using tap water to rinse off debris will make a clinical difference to the surface detail of a gypsum cast is unknown. In addition, how best to remove debris from the cast is unknown. The purpose of this in vitro study was to evaluate the efficiency of different methods of cleaning a gypsum cast after trimming and the effect of short-term exposure to tap water on the surface quality of the cast. A die fitting American National Standards Institute/American Dental Association specification 25 (International Standards Organization specification 6873) for dental gypsum products was embedded in a Dentoform with the machined lines positioned at the same level as the occlusal surface of the posterior teeth. A flat plate was used to ensure that the plane of occlusion for the die was at the same position as the posterior teeth. Forty polyvinyl siloxane impressions of the Dentoform were made and poured with vacuum-mixed improved Type IV dental stone. Each cast was inspected for the accurate reproduction of the lines. The base of the 2-stage pour was trimmed with a cast trimmer with water, and surface debris was removed by rinsing by hand under tap water for 10 seconds, by brushing the cast with a soft toothbrush for 10 seconds, or by resoaking the cast and using a soft camel hair brush in slurry water for 10 seconds. The amount of debris was evaluated on a scale of 1 to 4, and the quality of the 20-μm line was evaluated on a scale of 1 to 4 under ×15 magnification. The nonparametric Kruskal-Wallis ranks test was used to identify significant differences among the different cleaning methods (α=.05). Results of the Kruskal-Wallis and Kruskal-Wallis Z-value tests demonstrated that all cleaning methods produced cleaner casts than were observed for uncleansed controls (P<.001), but no differences in debris removal were found among the different cleaning methods (.065≤P≤.901). The ability to see the quality of a 20-μm line (P=.974) was not statistically different

  1. Investigation of effective forensic cleaning methods for bullet and cartridge case samples

    Science.gov (United States)

    Shuherk, Cassie Marie

    Bullet and cartridge case evidence may potentially link weapons and crimes through the comparison of toolmark patterns. This analysis relies on the clarity of the toolmarks and the ability of the examiner to identify patterns on the evidence. These patterns may be distorted by debris such as soil, blood, cyanoacrylate, and construction materials. Despite the potential importance of bullet and cartridge case evidence, few investigations of proper cleaning methods have been conducted. The present study was designed to examine the effects of various cleaning solutions and application methods on copper and brass bullets and cartridge cases. Additionally, this research investigated the efficacy of these cleaning protocols on the common evidence contaminants blood and cyanoacrylate. No cleaning method was found to be universally effective on both contaminant types and nondestructive to the metal surface. Ultrasonication was the most efficient application method employed when used in conjunction with an appropriate cleaning solution. Acetone proved to be safe and successful at removing heavy cyanoacrylate deposits from brass cartridge cases without damaging the metal. Although sulfuric acid removed most of the cyanoacrylate from the brass cartridge case, ultrasonication of the fumed cartridge cases in sulfuric acid caused the nickel-plated primer caps to turn black. Additionally, etching occurred when sulfuric acid was allowed to dry on the cartridge case surface. Citric acid, salt-flour-vinegar paste, TergazymeRTM, and water did not effectively remove the cyanoacrylate from the cartridge cases, but the solutions were safe to use on the brass and sometimes resulted in a shinier surface. Regardless of the cleaning method employed, the bloodstained bullets retained most or all of the underlying brown tarnish. Ultrasonication with sulfuric acid was successful at removing some blood-initiated tarnishing; however, the removal of residues was not complete, making it difficult

  2. Contact lens use and its compliance for care among healthcare workers in Pakistan

    Directory of Open Access Journals (Sweden)

    Muhammed Hamza Khan

    2013-01-01

    Full Text Available Background: Poor care and hygiene of contact lens (CL results in eye problems and infections. Healthcare workers have an important role in advocating correct lens care. Objectives: To determine the practices of CL care and the adverse consequences of poor CL care among healthcare workers. Setting and Design: A cross-sectional study in one public and three private sector hospitals in Karachi, Pakistan, in 2009-2010. Materials and Methods: We questioned 500 healthcare workers of all ages and both sexes, who wore CL, about compliance with advice on care and any complications due to improper hygiene practices. Ethical approval was obtained. Chi-square tests were used to determine significance and p-value less than 0.05 was considered statistically significant. Results: Of the total CL users, 385 (77% were females. Most (75% respondents wore CL to correct myopia, whereas 54% wore CL only occasionally. Surprisingly, only 24% knew the CL cleaning protocol. Lens solution was changed daily by 33% of users and after more than 2 weeks by 42%. Although 412 (82% participants practised reasonable hand hygiene before inserting CL, 88 (18% did not. Infection and eye dryness were statistically significantly (P < 0.01 associated with sex, hand-washing, and frequency of CL use. Conclusion: Noncompliance with the CL protocol was common among healthcare workers in our society. This behavior calls for targeted health education and awareness programs for healthcare workers.

  3. Ensuring clean air: Developing a clean air strategy for British Columbia

    International Nuclear Information System (INIS)

    1992-04-01

    In 1992, a clean air strategy will be developed to incorporate views of British Columbians on ways to meet goals related to air quality. A discussion paper is presented to provide information to those interested in participation in developing this strategy. The paper gives information on air quality issues important to the province, including local air quality, urban smog, ozone layer depletion, and global climate change. The views and concerns expressed by stakeholders who attended the Clean Air Conference in 1991 are summarized. The process used to develop the clean air strategy is outlined and some outcomes to be anticipated from the strategy are suggested, including policies and priorities for action to ensure clean air. Air pollutants of concern are total reduced sulfur, mainly from pulp mills and gas processing plants; smoke from wood burning; sulfur dioxide from pulp mills and gas plants; hydrogen fluoride from aluminum smelting; ground-level ozone in urban areas; and acid rain. Elements of a clean air strategy include a smoke management policy, management strategies for greenhouse gases and ozone smog, ozone layer protection measures, regional air quality management plans, and long-term planning efforts in energy use, transportation modes, community design, and land use. 12 refs., 14 figs., 2 tabs

  4. Surface properties and self-cleaning ability of the fluorinated acrylate coatings modified with dodecafluoroheptyl methacrylate through two adding ways

    International Nuclear Information System (INIS)

    Yang, Xin; Zhu, Liqun; Zhang, Yang; Chen, Yichi; Bao, Baiqing; Xu, Jinlong; Zhou, Weiwei

    2014-01-01

    Highlights: • A self-cleaning test is used to evaluate the self-cleaning ability of coatings. • Adding way of fluorine monomer has an influence on the self-cleaning ability. • The fluorine content of coating surface increases by changing modification method. • High contact angles and low sliding angles are advantageous for self-cleaning. • The self-cleaning ability of coatings is analyzed after scrubbing. - Abstract: The fluorine-modified acrylate resin was synthesized by solution radical polymerization using dodecafluoroheptyl methacrylate (DFMA) and other acrylate monomers. The same weight of DFMA was added into the reaction through two different ways: (1) adding DFMA as bottom monomer (AFBM); (2) adding DFMA drop by drop (AFDD). The different coatings were prepared by blending the fluorine-modified acrylate resin with the curing agent. Compared with AFDD coating, the AFBM coating exhibited better self-cleaning ability which was confirmed by the self-cleaning test through measuring the specular gloss of coatings before contamination and after water droplets flushing. The fluorine content at the surface of AFBM coating increased from 15.1 at.% to 23.1 at.%, while the water contact angles increased by 8° and the sliding angles decreased obviously. Furthermore, the contact angles and self-cleaning ability of the coatings prepared with DFMA through two adding ways both decreased after scrubbing by wet cotton because of the decrease of the surface fluorine atom content. It could be concluded that high contact angles and low sliding angles were advantageous for coatings to obtain excellent self-cleaning ability

  5. Surface properties and self-cleaning ability of the fluorinated acrylate coatings modified with dodecafluoroheptyl methacrylate through two adding ways

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xin [Key Laboratory of Aerospace Advanced Materials and Performance (Ministry of Education), School of Material Science and Engineering, Beihang University, Beijing 100191 (China); Zhu, Liqun, E-mail: zhulq@buaa.edu.cn [Key Laboratory of Aerospace Advanced Materials and Performance (Ministry of Education), School of Material Science and Engineering, Beihang University, Beijing 100191 (China); Zhang, Yang [Key Laboratory of Aerospace Advanced Materials and Performance (Ministry of Education), School of Material Science and Engineering, Beihang University, Beijing 100191 (China); Chen, Yichi [Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry and Environment, Beihang University, Beijing 100191 (China); Bao, Baiqing; Xu, Jinlong; Zhou, Weiwei [Jiangsu Baihe Coatings Co., Ltd, Changzhou 213136 (China)

    2014-03-01

    Highlights: • A self-cleaning test is used to evaluate the self-cleaning ability of coatings. • Adding way of fluorine monomer has an influence on the self-cleaning ability. • The fluorine content of coating surface increases by changing modification method. • High contact angles and low sliding angles are advantageous for self-cleaning. • The self-cleaning ability of coatings is analyzed after scrubbing. - Abstract: The fluorine-modified acrylate resin was synthesized by solution radical polymerization using dodecafluoroheptyl methacrylate (DFMA) and other acrylate monomers. The same weight of DFMA was added into the reaction through two different ways: (1) adding DFMA as bottom monomer (AFBM); (2) adding DFMA drop by drop (AFDD). The different coatings were prepared by blending the fluorine-modified acrylate resin with the curing agent. Compared with AFDD coating, the AFBM coating exhibited better self-cleaning ability which was confirmed by the self-cleaning test through measuring the specular gloss of coatings before contamination and after water droplets flushing. The fluorine content at the surface of AFBM coating increased from 15.1 at.% to 23.1 at.%, while the water contact angles increased by 8° and the sliding angles decreased obviously. Furthermore, the contact angles and self-cleaning ability of the coatings prepared with DFMA through two adding ways both decreased after scrubbing by wet cotton because of the decrease of the surface fluorine atom content. It could be concluded that high contact angles and low sliding angles were advantageous for coatings to obtain excellent self-cleaning ability.

  6. ''How clean is clean'' in the United States federal and Washington State cleanup regulations

    International Nuclear Information System (INIS)

    Landau, H.G.

    1993-01-01

    The enactment of legislation and promulgation of implementing regulations generally involves the resolution of conflicting goals. Defining ''How Clean is Clean?'' in federal and state cleanup laws, regulations, and policies is no exception. Answering the ''How Clean is Clean?'' question has resulted in the identification of some important and sometimes conflicting goals. Continuing resolution of the following conflicting goals is the key to effect cleanup of hazardous waste sites: Expediency vs. Fairness; Flexibility vs. Consistency; Risk Reduction vs. Risk Causation; and Permanence vs. Cost Effectiveness

  7. Cleaning of road accessories with powdered sodium bicarbonate; Jutansan natrium ryu wo mochiita doro fuzokubutsu no senjo

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, H.; Amagori, Y.; Mori, E. [Japan Highway Public Corporation, Tokyo (Japan)

    1998-06-25

    A method for cleaning highway accessories with powdered sodium bicarbonate is developed, to replace mechanical cleaning by a multi-purpose vehicle or manual cleaning, and thereby to reduce road maintenance cost. It pneumatically blows sodium bicarbonate particles by a blaster connected to a water tank and compressor onto a variety of stains to remove them. The cleaning system is applicable to a variety of purposes, allowing dry and wet cleaning modes to be easily switched from each other. Sodium bicarbonate, being naturally occurring, is harmless, and its type can be freely chosen. This method was applied in FY1996 mainly to cleaning interior plates in highways, to collect the basic data. Its cleaning effectiveness has been confirmed by applying it to the internal plates, which are difficult to clean by a multi-purpose vehicle, and illuminators in tunnels, whose cleaning areas are narrow. It recovers reflectivity of plates to 85% of the initial level at the highest, and shows 3 times higher efficiency for heavily stained plates. The test was continued in FY1997. It shows an approximately 5 times higher cleaning capacity than the conventional method, greatly reducing cleaning time, especially for illuminators in tunnels. 7 figs., 5 tabs.

  8. Benchmarks of Global Clean Energy Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sandor, Debra [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chung, Donald [National Renewable Energy Lab. (NREL), Golden, CO (United States); Keyser, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mann, Margaret [National Renewable Energy Lab. (NREL), Golden, CO (United States); Engel-Cox, Jill [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-01-01

    The Clean Energy Manufacturing Analysis Center (CEMAC), sponsored by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), provides objective analysis and up-to-date data on global supply chains and manufacturing of clean energy technologies. Benchmarks of Global Clean Energy Manufacturing sheds light on several fundamental questions about the global clean technology manufacturing enterprise: How does clean energy technology manufacturing impact national economies? What are the economic opportunities across the manufacturing supply chain? What are the global dynamics of clean energy technology manufacturing?

  9. Influence of wet chemical cleaning on quantum efficiency of GaN photocathode

    International Nuclear Information System (INIS)

    Wang Xiao-Hui; Gao Pin; Wang Hong-Gang; Li Biao; Chang Ben-Kang

    2013-01-01

    GaN samples 1–3 are cleaned by a 2:2:1 solution of sulfuric acid (98%) to hydrogen peroxide (30%) to de-ionized water; hydrochloric acid (37%); or a 4:1 solution of sulfuric acid (98%) to hydrogen peroxide (30%). The samples are activated by Cs/O after the same annealing process. X-ray photoelectron spectroscopy after the different ways of wet chemical cleaning shows: sample 1 has the largest proportion of Ga, N, and O among the three samples, while its C content is the lowest. After activation the quantum efficiency curves show sample 1 has the best photocathode performance. We think the wet chemical cleaning method is a process which will mainly remove C contamination. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  10. A new cleaning process for the metallic contaminants on a post-CMP wafer's surface

    International Nuclear Information System (INIS)

    Gao Baohong; Liu Yuling; Wang Chenwei; Wang Shengli; Zhou Qiang; Tan Baimei; Zhu Yadong

    2010-01-01

    This paper presents a new cleaning process using boron-doped diamond (BDD) film anode electrochemical oxidation for metallic contaminants on polished silicon wafer surfaces. The BDD film anode electrochemical oxidation can efficiently prepare pyrophosphate peroxide, pyrophosphate peroxide can oxidize organic contaminants, and pyrophosphate peroxide is deoxidized into pyrophosphate. Pyrophosphate, a good complexing agent, can form a metal complex, which is a structure consisting of a copper ion, bonded to a surrounding array of two pyrophosphate anions. Three polished wafers were immersed in the 0.01 mol/L CuSO 4 solution for 2 h in order to make comparative experiments. The first one was cleaned by pyrophosphate peroxide, the second by RCA (Radio Corporation of America) cleaning, and the third by deionized (DI) water. The XPS measurement result shows that the metallic contaminants on wafers cleaned by the RCA method and by pyrophosphate peroxide is less than the XPS detection limits of 1 ppm. And the wafer's surface cleaned by pyrophosphate peroxide is more efficient in removing organic carbon residues than RCA cleaning. Therefore, BDD film anode electrochemical oxidation can be used for microelectronics cleaning, and it can effectively remove organic contaminants and metallic contaminants in one step. It also achieves energy saving and environmental protection. (semiconductor technology)

  11. Evaluation of methods for cleaning low carbon uranium metal and alloy samples

    International Nuclear Information System (INIS)

    Kirchner, K.; Dixon, M.

    1979-01-01

    Several methods for cleaning uranium samples prior to carbon analysis, using a Leco Carbon Analyzer, were evaluated. Use of Oakite Aluminum NST Cleaner followed by water and acetone rinse was found to be the best overall technique

  12. Diamond-cleaning investigations

    International Nuclear Information System (INIS)

    Derry, T.E.

    Four parcels of diamonds which either had or had not been cleaned using the usual techniques, chiefly involving etch in molten potassium nitrate were supplied by De Beers Diamond Research Laboratories. Each parcel contained about 40 stones, amounting to about 10 carats. Half the diamonds in each parcel were cleaned by a standard procedure involving half an hours ultrasonic agitation in a 20% solution of the commercial detergent 'Contrad' which is effectively a surfactant and chelating agent. Visual comparisons by a number of observers who were not told the stones' histories, established that these diamonds generally had a more sparkling appearance after the cleaning procedure had been applied

  13. National Alliance for Clean Energy Incubators New Mexico Clean Energy Incubator

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Suzanne S.

    2004-12-15

    The National Alliance for Clean Energy Incubators was established by the National Renewable Energy Laboratory (NREL) to develop an emerging network of business incubators for entrepreneurs specializing in clean energy enterprises. The Alliance provides a broad range of business services to entrepreneurs in specific geographic locales across the U.S. and in diverse clean energy technology areas such as fuel cells, alternative fuels, power generation, and renewables, to name a few. Technology Ventures Corporation (TVC) participates in the Alliance from its corporate offices in Albuquerque, NM, and from its sites in Northern and Southern New Mexico, California, and Nevada. TVC reports on the results of its attempts to accelerate the growth and success of clean energy and energy efficiency companies through its array of business support services. During the period from September 2002 through September 2004, TVC describes contributions to the Alliance including the development of 28 clients and facilitating capital raises exceeding $35M.

  14. Drag of Clean and Fouled Net Panels--Measurements and Parameterization of Fouling.

    Directory of Open Access Journals (Sweden)

    Lars Christian Gansel

    Full Text Available Biofouling is a serious problem in marine aquaculture and it has a number of negative impacts including increased forces on aquaculture structures and reduced water exchange across nets. This in turn affects the behavior of fish cages in waves and currents and has an impact on the water volume and quality inside net pens. Even though these negative effects are acknowledged by the research community and governmental institutions, there is limited knowledge about fouling related effects on the flow past nets, and more detailed investigations distinguishing between different fouling types have been called for. This study evaluates the effect of hydroids, an important fouling organism in Norwegian aquaculture, on the forces acting on net panels. Drag forces on clean and fouled nets were measured in a flume tank, and net solidity including effect of fouling were determined using image analysis. The relationship between net solidity and drag was assessed, and it was found that a solidity increase due to hydroids caused less additional drag than a similar increase caused by change in clean net parameters. For solidities tested in this study, the difference in drag force increase could be as high as 43% between fouled and clean nets with same solidity. The relationship between solidity and drag force is well described by exponential functions for clean as well as for fouled nets. A method is proposed to parameterize the effect of fouling in terms of an increase in net solidity. This allows existing numerical methods developed for clean nets to be used to model the effects of biofouling on nets. Measurements with other types of fouling can be added to build a database on effects of the accumulation of different fouling organisms on aquaculture nets.

  15. Sustainable development with clean coal

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    This paper discusses the opportunities available with clean coal technologies. Applications include new power plants, retrofitting and repowering of existing power plants, steelmaking, cement making, paper manufacturing, cogeneration facilities, and district heating plants. An appendix describes the clean coal technologies. These include coal preparation (physical cleaning, low-rank upgrading, bituminous coal preparation); combustion technologies (fluidized-bed combustion and NOx control); post-combustion cleaning (particulate control, sulfur dioxide control, nitrogen oxide control); and conversion with the integrated gasification combined cycle.

  16. Clean Energy Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    For the past several years, the IEA and others have been calling for a clean energy revolution to achieve global energy security, economic growth and climate change goals. This report analyses for the first time progress in global clean energy technology deployment against the pathways that are needed to achieve these goals. It provides an overview of technology deployment status, key policy developments and public spending on RDD&D of clean energy technologies.

  17. 33 CFR Appendix D to Part 157 - Example of a Procedure for Dedicated Clean Ballast Tanks Operations

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Example of a Procedure for... ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Pt. 157, App. D Appendix D to Part 157—Example of a Procedure for Dedicated Clean Ballast Tanks Operations 1. Source. The example procedure for dedicated clean...

  18. Basics about online boiler cleaning according to the Schwandorf principle; Grundlagen zur Online-Kesselreinigung nach dem Schwandorfer Prinzip

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Joerg [VWT Ing.-Buero, Schwandorf (Germany); Krueger, Sascha [IBK-Verfahrenstechnik, Bad Berka (Germany)

    2013-10-01

    In the Schwandorf waste-to-energy (WtE) plant more than ten years ago a wet online boiler cleaning system was developed which has the capability to clean the radiation passes of (WtE-, biomass- and refuse derived fuel (RDF)) boilers without damaging the boiler. During the development it was recognised that the method of atomising the washing agent (water) is highly influencing the effectiveness of cleaning by securing parts of the boiler (membrane walls). (orig.)

  19. Evaluation of Membrane Ultrafiltration and Residual Chlorination as a Decentralized Water Treatment Strategy for Ten Rural Healthcare Facilities in Rwanda

    Directory of Open Access Journals (Sweden)

    Alexandra Huttinger

    2015-10-01

    Full Text Available There is a critical need for safe water in healthcare facilities (HCF in low-income countries. HCF rely on water supplies that may require additional on-site treatment, and need sustainable technologies that can deliver sufficient quantities of water. Water treatment systems (WTS that utilize ultrafiltration membranes for water treatment can be a useful technology in low-income countries, but studies have not systematically examined the feasibility of this technology in low-income settings. We monitored 22 months of operation of 10 WTS, including pre-filtration, membrane ultrafiltration, and chlorine residual disinfection that were donated to and operated by rural HCF in Rwanda. The systems were fully operational for 74% of the observation period. The most frequent reasons for interruption were water shortage (8% and failure of the chlorination mechanism (7%. When systems were operational, 98% of water samples collected from the HCF taps met World Health Organization (WHO guidelines for microbiological water quality. Water quality deteriorated during treatment interruptions and when water was stored in containers. Sustained performance of the systems depended primarily on organizational factors: the ability of the HCF technician to perform routine servicing and repairs, and environmental factors: water and power availability and procurement of materials, including chlorine and replacement parts in Rwanda.

  20. Recherche | Page 5 | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Uganda, as in other African countries, doctors and healthcare workers often don't ... typhoid education about cleaning the water, asking people to boil water.”. ... Yet by 2002, Southern Africa had the world's highest HIV prevalence rates, the ... to regulate and cross-subsidize services such as water supplies and health.

  1. Nuclear air cleaning programs in progress in France

    International Nuclear Information System (INIS)

    Mulcey, P.

    1991-01-01

    A short presentation is given of the nuclear air cleaning programs in progress in France with respect to pressurized water reactors, fuel reprocessing plants, radioactive waste management facilities, and the dismantling of nuclear facilities. The effects of fires in rooms and ventilation ducts in all nuclear facilities is being studied and computer simulation codes are being developed. A brief review of filter development and filter testing is also presented

  2. Development of Natural Gas Fired Combined Cycle Plant for Tri-Generation of Power, Cooling and Clean Water Using Waste Heat Recovery: Techno-Economic Analysis

    OpenAIRE

    Mohan, Gowtham; Dahal, Sujata; Kumar, Uday; Martin, Andrew; Kayal, Hamid

    2014-01-01

    Tri-generation is one of the most efficient ways for maximizing the utilization of available energy. Utilization of waste heat (flue gases) liberated by the Al-Hamra gas turbine power plant is analyzed in this research work for simultaneous production of: (a) electricity by combining steam rankine cycle using heat recovery steam generator (HRSG); (b) clean water by air gap membrane distillation (AGMD) plant; and (c) cooling by single stage vapor absorption chiller (VAC). The flue gases liber...

  3. ATP Bioluminometers Analysis on the Surfaces of Removable Orthodontic Aligners after the Use of Different Cleaning Methods

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2016-01-01

    Full Text Available Purpose. The aim was to quantify the bacteria concentration on the surface of orthodontic clear aligners using three different cleaning methods. Furthermore the objective was to validate the efficacy of the bioluminometer in assessing the bacteria concentration. Materials and Methods. Twenty subjects (six males and fourteen females undergoing orthodontic therapy with clear aligners (Invisalign® Align Technology, Santa Clara, California were enrolled in this study. The observation time was of six weeks. The patients were instructed to use different cleaning methods (water, brushing with toothpaste, and brushing with toothpaste and use of sodium carbonate and sulphate tablet. At the end of each phase a microbiological analysis was performed using the bioluminometer. Results. The highest bacteria concentration was found on aligners cleaned using only water (583 relative light units; a value of 189 relative light units was found on aligners cleaned with brushing and toothpaste. The lowest bacteria concentration was recorded on aligners cleaned with brushing and toothpaste and the use of sodium carbonate and sulfate tablet. Conclusions. The mechanical removal of the bacterial biofilm proved to be effective with brushing and toothpaste. The best results in terms of bacteria concentration were achieved adding the use of sodium carbonate and sulfate tablet.

  4. ATP Bioluminometers Analysis on the Surfaces of Removable Orthodontic Aligners after the Use of Different Cleaning Methods.

    Science.gov (United States)

    Levrini, Luca; Mangano, Alessandro; Margherini, Silvia; Tenconi, Camilla; Vigetti, Davide; Muollo, Raffaele; Marco Abbate, Gian

    2016-01-01

    Purpose. The aim was to quantify the bacteria concentration on the surface of orthodontic clear aligners using three different cleaning methods. Furthermore the objective was to validate the efficacy of the bioluminometer in assessing the bacteria concentration. Materials and Methods. Twenty subjects (six males and fourteen females) undergoing orthodontic therapy with clear aligners (Invisalign® Align Technology, Santa Clara, California) were enrolled in this study. The observation time was of six weeks. The patients were instructed to use different cleaning methods (water, brushing with toothpaste, and brushing with toothpaste and use of sodium carbonate and sulphate tablet). At the end of each phase a microbiological analysis was performed using the bioluminometer. Results. The highest bacteria concentration was found on aligners cleaned using only water (583 relative light units); a value of 189 relative light units was found on aligners cleaned with brushing and toothpaste. The lowest bacteria concentration was recorded on aligners cleaned with brushing and toothpaste and the use of sodium carbonate and sulfate tablet. Conclusions. The mechanical removal of the bacterial biofilm proved to be effective with brushing and toothpaste. The best results in terms of bacteria concentration were achieved adding the use of sodium carbonate and sulfate tablet.

  5. R&D 100 Awards Demonstrate Clean Energy Legacy - Continuum Magazine |

    Science.gov (United States)

    Intel to develop an innovative warm-water, liquid-cooled supercomputer that later won an R&D 100 Award. Photo by Dennis Schroeder, NREL R&D 100 Awards Demonstrate Clean Energy Legacy NREL has won 57 R&D 100 Awards since 1982, many of which led directly to industry successes today. R&D 100

  6. The AREVA customized chemical cleaning C3-concept as part of the steam generator asset management

    International Nuclear Information System (INIS)

    Weiss, Steffen; Drexler, Andreas

    2012-09-01

    In pressurized water reactors corrosion products and impurities are transported into the steam generators by feed water. Corrosion products and impurities are accumulated in the SGs as deposits and scales on the tubes, the tube support structures and the tube sheet. Depending on the location, the composition and the morphology such deposits may negatively affect the performance of the steam generators by reducing the thermal performance, changing the flow patterns and producing localized corrosion promoting conditions. Accordingly removal of deposits or deposit minimization strategies are an essential part of the asset management program of the steam generators in Nuclear Power Plants. It is evident that such a program is plant specific, depending on the individual condition prevailing. Parameters to be considered are for example: - Steam generator and balance of plant design; - Secondary side water chemistry treatment; - Deposit amount and constitution; - Deposit distribution in the steam generator; - Existing or expected corrosion problems. After evaluation of the steam generator condition a strategy for deposit minimization has to be developed. Depending on the individual situation such strategies may span from curative full scale cleanings which are capable of removing the entire sludge inventory in the range of several 1000 kg per SG to preventive cleanings that remove only a portion of the deposits in the range of several 100 kg per SG. But also other goals depending on the specific plant situation, like tube sheet sludge piles or hard scale removal, may be considered. Beside the chemical cleaning process itself also the integration of the process into the outage schedule and considerations about its impact on other maintenance activities is of great importance. It is obvious that all these requirements cannot be met easily by a standardized cleaning method, thus a customisable chemical cleaning technology is required. Based on its comprehensive experience

  7. Clean Energy Policy Analysis: Impact Analysis of Potential Clean Energy Policy Options for the Hawaii Clean Energy Initiative (HCEI)

    Energy Technology Data Exchange (ETDEWEB)

    Busche, S.; Doris, E.; Braccio, R.; Lippert, D.; Finch, P.; O' Toole, D.; Fetter, J.

    2010-04-01

    This report provides detailed analyses of 21 clean energy policy options considered by the Hawaii Clean Energy Initiative working groups for recommendation to the 2010 Hawaii State Legislature. The report considers the impact each policy may have on ratepayers, businesses, and the state in terms of energy saved, clean energy generated, and the financial costs and benefits. The analyses provide insight into the possible impacts, both qualitative and quantitative, that these policies may have in Hawaii based on the experience with these policies elsewhere. As much as possible, the analyses incorporate Hawaii-specific context to reflect the many unique aspects of energy use in the State of Hawaii.

  8. Laser cleaning of Rakowicze sandstone

    NARCIS (Netherlands)

    Nijland, T.G.; Wijffels, T.J.

    2003-01-01

    Decisions about the cleaning of natural stone should always be made within the awareness of direct and indirect damage that may be the result of cleaning. During the last decade, laser cleaning of objects and monuments of natural stone has become increasingly popular. Whereas a considerable amount

  9. Cleanings of the silica scale settled in the transportation-pipes of the geothermal hot water of the Onuma Geothermal Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Ito, J

    1978-09-01

    At the Onuma Geothermal Power Station, silica scale deposits in the hot water transportation pipes between production wells and injection wells, increased the thickness. The operations for cleaning the scale were effectively carried out by the following three methods. (1) Poli-Pig method: The shell-shaped plastic foam sponge mass named Poli-Pig was pressed in the pipes. Various shaped Poli-Pig such as armed by the steel spikes made scratches on the surface of the scale, and then stripped off. This method is effective when thickness of the scale is thinner than 20 mm. (2) Impact-Cutter method. Various shaped steel cutter blocks were attached at the end of a flexible shaft, and gave continuous impact by rotation on the scale and then smashing it away. This method is effective for various thickness, but pipes had to be cut off matched to the length of the flexible shaft. (3) Water-jet method. High pressured water jet through the special nozzle smashed away the scale. For this method the pipe had to be cut off at every joint.

  10. 76 FR 24479 - EPA and Army Corps of Engineers Guidance Regarding Identification of Waters Protected by the...

    Science.gov (United States)

    2011-05-02

    ... Waters Protected by the Clean Water Act AGENCY: Environmental Protection Agency (EPA); and U.S. Army... will identify waters protected by the Federal Water Pollution Control Act Amendments of 1972 (Clean... guidance the number of waters identified as protected by the Clean Water Act will increase compared to...

  11. Alkali-assisted membrane cleaning for fouling control of anaerobic ceramic membrane bioreactor.

    Science.gov (United States)

    Mei, Xiaojie; Quek, Pei Jun; Wang, Zhiwei; Ng, How Yong

    2017-09-01

    In this study, a chemically enhanced backflush (CEB) cleaning method using NaOH solution was proposed for fouling mitigation in anaerobic membrane bioreactors (AnMBRs). Ex-situ cleaning tests revealed that NaOH dosages ranging from 0.05 to 1.30mmol/L had positive impacts on anaerobic biomass, while higher dosages (>1.30mmol/L) showed inhibition and/or toxic impacts. In-situ cleaning tests showed that anaerobic biomass could tolerate much higher NaOH concentrations due to the alkali consumption by anaerobic process and/or the buffering role of mixed liquor. More importantly, 10-20mmol-NaOH/L could significantly reduce membrane fouling rates (4-5.5 times over the AnMBR with deionized water backflush) and slightly improve methanogenic activities. COD removal efficiencies were over 87% and peaked at 20mmol-NaOH/L. However, extremely high NaOH concentration had adverse effects on filtration and treatment performance. Economic analysis indicated that 12mmol/L of NaOH was the cost-efficient and optimal fouling-control dosage for the CEB cleaning. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Enhanced Cleaning of Genesis Solar Wind Sample 61348 for Film Residue Removal

    Science.gov (United States)

    Allums, K. K.; Gonzalez, C. P.; Kuhlman, K. R.; Allton, J. H.

    2015-01-01

    The Genesis mission returned to Earth on September 8, 2004, experiencing a nonnominal reentry. During the recovery of the collector materials from the capsule, many of the collector fragments were placed on the adhesive protion of post-it notes to prevent the fragments from moving during transport back to Johnson Space Center. This unknowingly provided an additional contaminate that would prove difficult to remove with the limited chemistries allowed in the Genesis Curation Laboratory. Generally when collector material samples are prepared for allocation to PIs, the samples are cleaned front side only with Ultra-Pure Water (UPW) via megasonic dispersion to the collector surface to remove crash debris and contamination. While this cleaning method works well on samples that were not placed on post-its during recovery, it has caused movement of the residue on the back of the sample to be deposited on the front in at least two examples. Therefore, samples placed on the adhesive portion on post-it note, require enhanced cleaning methods since post-it residue has proved resistant to UPW cleaning.

  13. Anti-icing/frosting and self-cleaning performance of superhydrophobic aluminum alloys

    Science.gov (United States)

    Feng, Libang; Yan, Zhongna; Shi, Xueting; Sultonzoda, Firdavs

    2018-02-01

    Ice formation and frost deposition on cryogenic equipment and systems can result in serious problems and huge economic loss. Hence, it is quite necessary to develop new materials to prevent icing and frosting on cold surfaces in engineering fields. Here, a superhydrophobic aluminum alloy with enhanced anti-frosting, anti-icing, and self-cleaning performance has been developed by a facile one-step method. The anti-frosting/icing performance of superhydrophobic aluminum alloys is confirmed by frosting/icing time delay, consolidating and freezing temperature reduction, and lower amount of frost/ice adhesion. Meanwhile, the excellent self-cleaning performance is authenticated by the fact that simulated pollution particles can be cleaned out by rolling water droplets completely. Finally, based on the classical nucleation theory, anti-icing and anti-frosting mechanisms of the superhydrophobic aluminum alloys are deduced. Results show that grounded on "air cushion" and "heat insulation" effect, a larger nucleation barrier and a lower crystal growth rate can be observed, which, hence, inhibit ice formation and frost deposition. It can be concluded that preparing superhydrophobic surfaces would be an effective strategy for improving anti-icing, anti-frosting, and self-cleaning performance of aluminum alloys.

  14. Validation of the cleaning and sanitization method for radiopharmaceutical production facilities

    International Nuclear Information System (INIS)

    Robles, Anita; Morote, Mario; Moore, Mariel; Castro, Delcy; Paragulla, Wilson; Novoa, Carlos; Otero, Manuel; Miranda, Jesus; Herrera, Jorge; Gonzales, Luis

    2014-01-01

    A protocol for the cleaning and sanitization method for radiopharmaceutical production facilities has been designed and developed for the inner surface of the hot cells for the production of Sodium Pertechnetate Tc-99m and Sm-153 EDTMP, considering an extreme situation for each hot cell. Cleaning is performed with double-distilled water and sanitation with two disinfectant solutions, 70 % isopropyl alcohol and 3 % hydrogen peroxide in alternate weeks. Microbiological analysis of sanitized surfaces were made after 20 minutes and 48 hours for the hot cell of Tc-99m and 72 hours for the hot cell of EDTMP Sm-153 in 3 consecutive tests by the method of direct contact with plates containing culture medium, made for each sampling point (6 in the first and five in the second). The results showed that the microbial load on surfaces sanitized was below acceptable limits and that the lifetime of cleaning and sanitization is 48 hours for the hot cell of Tc-99m and 72 hours for the one of EDTMP-Sm-153. As a conclusion, the method of cleaning and sanitization is effective to reduce or eliminate microbial contamination therefore, the process is validated. (authors).

  15. Surface cleaning in thin film technology

    International Nuclear Information System (INIS)

    Mattox, D.M.

    1978-01-01

    A ''clean surface'' is one that contains no significant amounts of undesirable material. This paper discusses the types and origin of various contaminants. Since cleaning is often equated with adhesion, the mechanisms of adhesion to oxide, metal, and organic surfaces are reviewed and cleaning processes for these surfaces are outlined. Techniques for monitoring surface cleaning are presented, and the importance of storage of clean surfaces is discussed. An extensive bibliography is given. 4 figs., 89 references

  16. Fair share: Water Demand Management can help provide fair ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The Millennium Development Goals identify lack of clean water supply as a key factor in the lives of the poor. Eighty percent of poor people questioned in 20 countries rated lack of access to clean water as one of the main reasons for their situation. By saving water, WDM contributes to improved access to fresh water, can ...

  17. Surface wastewater in Samara and their impact on water basins as water supply sources

    Science.gov (United States)

    Strelkov, Alexander; Shuvalov, Mikhail; Gridneva, Marina

    2017-10-01

    The paper gives an overview of surface wastewater outlets in Samara through the rainwater sewer system into the Saratov water reservoir and the Samara river. The rainwater sewer system in Samara is designed and executed according to a separate scheme, except for the old part of the city, where surface run-off is dumped into the sewer system through siphoned drain. The rainwater system disposes of surface, drainage, industrial clean-contamined waters, emergency and technology discharges from the city’s heat supply and water supply systems. The effluent discharge is carried out by means of separate wastewater outlets into ravines or directly into the Samara river and the Saratov water reservoir without cleaning. The effluent discharge is carried out through the rainwater sewer system with 17 wastewater outlets into the Saratov water reservoir. In the Samara river, surface runoff drainage and clean-contamined water of industrial enterprises is carried out through 14 wastewater outlets. This study emphasizes the demand to arrange effluent discharge and construction of sewage treatment plants to prevent contamination of water objects by surface run-off from residential areas and industrial territories.

  18. Fire protection for clean rooms

    International Nuclear Information System (INIS)

    Kirson, D.

    1990-01-01

    The fire protection engineer often must decide what size fire can be tolerated before automatic fire suppression systems actuate. Is it a wastepaper basket fire, a bushel basket fire...? In the case of state-of-the-art clean rooms, the answer clearly is not even an incipient fire. Minor fires in clean rooms can cause major losses. This paper discusses what a clean room is and gives a brief overview of the unique fire protection challenges encountered. The two major causes of fire related to clean rooms in the semiconductor industry are flammable/pyrophoric gas fires in plastic ducts and polypropylene wet bench fires. This paper concentrates on plastic ductwork in clean rooms, sprinkler protection in ductwork, and protection for wet benches

  19. Study of chemical cleaning technique for removing sludge in secondary side of PWR SG

    International Nuclear Information System (INIS)

    Zhang Mengqin; Zhang Shufeng; Pan Qingchun; Yu Jinghua; Hou Shufeng

    1993-12-01

    The effect of components, concentration, pH, temperature, cleaning time and flowrate of chemical cleaning solvent made from EDTA mainly on Fe 3 O 4 solubility and corrosion rate of A3 carbon steel, S271 low alloy steel and 800 alloy are introduced. A small chemical cleaning test loop (30L) was built to study the cleaning technique. The effect of residue of chemical cleaning solvent on anti-corrosion performance of materials has been studied under the simulation condition of PWR (pressure water reactor) SG (steam generator) secondary side. The results show that the chemical solvent (pH = 7, 10% EDTA, 1% assistance solvent and 0.25% inhibitor A) can dissolve Fe 3 O 4 18 ∼23 g/L under the conditions of 93 +- 5 degree C, 8 hours and 112 r/min (1.8 ∼ 2.0 t/h). The corrosion rate of material is low. When the residue of EDTA is less than 0.01% there is no impact on the anti-corrosion performance of materials in PWR SG secondary side at normal operation condition (260 +- 5 degree C)

  20. Cleaner shrimp use a rocking dance to advertise cleaning service to clients.

    Science.gov (United States)

    Becker, Justine H A; Curtis, Lynda M; Grutter, Alexandra S

    2005-04-26

    Signals transmit information to receivers about sender attributes, increase the fitness of both parties, and are selected for in cooperative interactions between species to reduce conflict [1, 2]. Marine cleaning interactions are known for stereotyped behaviors [3-6] that likely serve as signals. For example, "dancing" and "tactile dancing" in cleaner fish may serve to advertise cleaning services to client fish [7] and manipulate client behavior [8], respectively. Cleaner shrimp clean fish [9], yet are cryptic in comparison to cleaner fish. Signals, therefore, are likely essential for cleaner shrimp to attract clients. Here, we show that the yellow-beaked cleaner shrimp [10] Urocaridella sp. c [11] uses a stereotypical side-to-side movement, or "rocking dance," while approaching potential client fish in the water column. This dance was followed by a cleaning interaction with the client 100% of the time. Hungry cleaner shrimp, which are more willing to clean than satiated ones [12], spent more time rocking and in closer proximity to clients Cephalopholis cyanostigma than satiated ones, and when given a choice, clients preferred hungry, rocking shrimp. The rocking dance therefore influenced client behavior and, thus, appears to function as a signal to advertise the presence of cleaner shrimp to potential clients.