WorldWideScience

Sample records for clean air standards

  1. Airing 'clean air' in Clean India Mission.

    Science.gov (United States)

    Banerjee, T; Kumar, M; Mall, R K; Singh, R S

    2017-03-01

    The submission explores the possibility of a policy revision for considering clean air quality in recently launched nationwide campaign, Clean India Mission (CIM). Despite of several efforts for improving availability of clean household energy and sanitation facilities, situation remain still depressing as almost half of global population lacks access to clean energy and proper sanitation. Globally, at least 2.5 billion people do not have access to basic sanitation facilities. There are also evidences of 7 million premature deaths by air pollution in year 2012. The situation is even more disastrous for India especially in rural areas. Although, India has reasonably progressed in developing sanitary facilities and disseminating clean fuel to its urban households, the situation in rural areas is still miserable and needs to be reviewed. Several policy interventions and campaigns were made to improve the scenario but outcomes were remarkably poor. Indian census revealed a mere 31% sanitation coverage (in 2011) compared to 22% in 2001 while 60% of population (700 million) still use solid biofuels and traditional cook stoves for household cooking. Further, last decade (2001-2011) witnessed the progress decelerating down with rural households without sanitation facilities increased by 8.3 million while minimum progress has been made in conversion of conventional to modern fuels. To revamp the sanitation coverage, an overambitious nationwide campaign CIM was initiated in 2014 and present submission explores the possibility of including 'clean air' considerations within it. The article draws evidence from literatures on scenarios of rural sanitation, energy practises, pollution induced mortality and climatic impacts of air pollution. This subsequently hypothesised with possible modification in available technologies, dissemination modes, financing and implementation for integration of CIM with 'clean air' so that access to both sanitation and clean household energy may be

  2. 77 FR 73459 - California State Motor Vehicle Pollution Control Standards; Notice of Waiver of Clean Air Act...

    Science.gov (United States)

    2012-12-10

    ... AGENCY California State Motor Vehicle Pollution Control Standards; Notice of Waiver of Clean Air Act..., challenging the need for CARB's own motor vehicle pollution control program based on lack of compelling and... Administrator shall waive preemption for California to enforce new motor vehicle emissions standards and...

  3. Clean air in the Anthropocene.

    Science.gov (United States)

    Lelieveld, Jos

    2017-08-24

    In atmospheric chemistry, interactions between air pollution, the biosphere and human health, often through reaction mixtures from both natural and anthropogenic sources, are of growing interest. Massive pollution emissions in the Anthropocene have transformed atmospheric composition to the extent that biogeochemical cycles, air quality and climate have changed globally and partly profoundly. It is estimated that mortality attributable to outdoor air pollution amounts to 4.33 million individuals per year, associated with 123 million years of life lost. Worldwide, air pollution is the major environmental risk factor to human health, and strict air quality standards have the potential to strongly reduce morbidity and mortality. Preserving clean air should be considered a human right, and is fundamental to many sustainable development goals of the United Nations, such as good health, climate action, sustainable cities, clean energy, and protecting life on land and in the water. It would be appropriate to adopt "clean air" as a sustainable development goal.

  4. Air Cleaning Technologies

    Science.gov (United States)

    2005-01-01

    Executive Summary Objective This health technology policy assessment will answer the following questions: When should in-room air cleaners be used? How effective are in-room air cleaners? Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone? What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan? The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario’s capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry’s Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Clinical Need Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering

  5. Clean Air Act Standards and Guidelines for Energy, Engines, and Combustion

    Science.gov (United States)

    This page contains the stationary sources of air pollution for the energy, engines, and combustion industries, and their corresponding air pollution regulations. To learn more about the regulations for each industry, just click on the links below.

  6. Clean Air OnLine

    Energy Technology Data Exchange (ETDEWEB)

    Finney, D. [Environment Canada, Gatineau, PQ (Canada). Air Pollution Prevention Directorate

    2004-04-07

    This presentation describes Clean Air OnLine, a multi-tiered website dedicated to providing Canadians with information on air quality. The website is under development to support action to reduce air emissions, demonstrate the links between air emissions and environmental impacts, and enhance the understanding of sustainable community development issues such as health, energy, and urban sprawl. Partners in the Clean Air OnLine (CAOL) initiative include Environment Canada and the Clean Air Partnership which includes the Greater Toronto Area pilot project. The audience for CAOL includes municipal decision makers, local decision makers, community leaders, and the general public. The project provides Canadians with air pollution contextual information on pollution sources, pollutants, and related issues. It also provides information on health, environmental and economic impacts and the interrelationships with climate change issues and energy use. tabs., figs.

  7. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  8. A method and device for cleaning air

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to a method and device for cleaning pollution from air wherin the air to be cleaned is subjected to a sequence of physical and chemical treatments.......The present invention relates to a method and device for cleaning pollution from air wherin the air to be cleaned is subjected to a sequence of physical and chemical treatments....

  9. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  10. Senate passes clean air bill

    Science.gov (United States)

    In an 89 to 11 vote the Senate passed a clean air bill aimed at reducing pollution by the turn of the century by imposing tougher controls on American industry. The bill is the first revision of the Clean Air Act of 1970 in 13 years and calls for new limits on auto pollution to clean up smog in most U.S. cities, decreasing by half emissions by power plants that cause acid rain to protect the ecology, and increasing technological controls on factories to protect against cancer-causing and toxic substances. The bill will add about $20 billion per year to the estimated $33 billion cost of complying with current pollution laws.

  11. Air cleaning using regenerative silica gel wheel

    DEFF Research Database (Denmark)

    Fang, Lei

    2011-01-01

    This paper discussed the necessity of indoor air cleaning and the state of the art information on gas-phase air cleaning technology. The performance and problems of oxidation and sorption air cleaning technology were summarized and analysed based on the literature studies. Eventually, based on an...

  12. Clean Air Act. Revision 5

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-15

    This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

  13. Allegheny County Clean Indoor Air Act Exemptions

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — List and location of all the businesses and social clubs who have received an exemption from the Pennsylvania Clean Indoor Air Act. “The Clean Indoor Air Act, Act...

  14. The Value of Clean Air

    Science.gov (United States)

    Shindell, D. T.

    2014-12-01

    How can society place a value on clean air? I present a multi-impact economic valuation framework called the Social Cost of Atmospheric Release (SCAR) that extends the Social Cost of Carbon (SCC) used previously for carbon dioxide (CO2) to a broader range of pollutants and impacts. Values consistently incorporate health impacts of air quality along with climate damages. The latter include damages associated with aerosol-induced hydrologic cycle changes that lead to net climate benefits when reducing cooling aerosols. Evaluating a 1% reduction in current global emissions, benefits with a high discount rate are greatest for reductions of co-emitted products of incomplete combustion (PIC), followed by sulfur dioxide (SO2), nitrogen oxides (NOx) and then CO2, ammonia and methane. With a low discount rate, benefits are greatest for CO2 reductions, though the sum of SO2, PIC and methane is substantially larger. These results suggest that efforts to mitigate atmosphere-related environmental damages should target a broad set of emissions including CO2, methane and aerosol/ozone precursors. Illustrative calculations indicate environmental damages are 410-1100 billion yr-1 for current US electricity generation ( 19-46¢ per kWh for coal, 4-24¢ for gas) and 3.80 (-1.80/+2.10) per gallon of gasoline ($4.80 (-3.10/+3.50) per gallon for diesel). These results suggest that total atmosphere-related environmental damages plus generation costs are much greater for coal-fired power than other types of electricity generation, and that damages associated with gasoline vehicles substantially exceed those for electric vehicles.

  15. Clean Air Markets - Compliance Query Wizard

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Compliance Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://ampd.epa.gov/ampd/. The Compliance module provides...

  16. Clean Air Markets - Allowances Query Wizard

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Allowances Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The Allowances...

  17. Clean Air Markets - Quick Facts and Trends

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Quick Facts and Trends module is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The...

  18. Clean air Hamilton 2001 progress report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-05-01

    This community initiative called Clean Air Hamilton was established to improve air quality in Hamilton, Ontario. It has been mandated to annually report on progress and provide advice with regard to current air quality issues. The quality of life of residents is improved as a result of the work performed by Clean Air Hamilton, and it also enhances Hamilton's image. Numerous inquiries have been received from City officials in several municipalities such as Toronto, Kitchener-Waterloo and Windsor as a testament to the success of the initiative. Financial support is received from all levels of government. The funding received from the Council has helped in attracting additional donations in support of this initiative. Clean Air Hamilton was involved in one capacity or another in research, emissions reduction projects and public awareness campaigns during 2001, and its contributions were valued at approximately 500,000 dollars. The City of Hamilton was awarded the United Nations for Human Settlements award as a result of Clean Air Hamilton's community process in local air quality improvement. In addition, the City received the Dubai International Award for Best Practices in Improving the Living Environment. Clean Air Hamilton is ready to move to the next phase, which requires moving current structures that supplements voluntary commitments with committed funding from key stakeholders. Since June 1996, the advisory level of 32 on the Air Pollution Index has not been reached, and rarely goes over 20. Throughout the 1990s, levels of toxics have decreased significantly. A three-year self-sustaining program should be developed and funding sought for those initiatives, discussions should be facilitated among industrial stakeholders when they address air quality issues, and research should continue to be supported and advice on current air quality issues be provided to City Council. 1 fig.

  19. 76 FR 40728 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence...

    Science.gov (United States)

    2011-07-11

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence Awards Program AGENCY: Environmental Protection Agency (EPA). ACTION: Request for nominations for Clean Air Excellence Awards. ] SUMMARY: EPA established the Clean Air Excellence Awards Program in...

  20. 75 FR 35025 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence...

    Science.gov (United States)

    2010-06-21

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence Awards Program AGENCY: Environmental Protection Agency (EPA). ACTION: Request for nominations for Clean Air Excellence Awards. SUMMARY: EPA established the Clean Air Excellence Awards Program in...

  1. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  2. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference; Sessions 1--8

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. [ed.] [Harvard Univ., Boston, MA (United States). Harvard Air Cleaning Lab.

    1991-02-01

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  3. 14 CFR 1260.34 - Clean air and water.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C....

  4. 33 CFR 157.220 - Dedicated clean ballast tanks: Standards.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated clean ballast tanks... CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels Design and Equipment § 157.220 Dedicated clean ballast tanks: Standards. (a) Cargo tanks that are designated as dedicated clean ballast...

  5. State Clean Energy Practices: Renewable Fuel Standards

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, G.; Kreycik, C.

    2008-07-01

    The State Clean Energy Policies Analysis (SCEPA) project is supported by the Weatherization and Intergovernmental Program within the Department of Energy's Office of Energy Efficiency and Renewable Energy. This project seeks to quantify the impacts of existing state policies, and to identify crucial policy attributes and their potential applicability to other states. The goal is to assist states in determining which clean energy policies or policy portfolios will best accomplish their environmental, economic, and security goals. For example, renewable fuel standards (RFS) policies are a mechanism for developing a market for renewable fuels in the transportation sector. This flexible market-based policy, when properly executed, can correct for market failures and promote growth of the renewable fuels industry better than a more command-oriented approach. The policy attempts to correct market failures such as embedded fossil fuel infrastructure and culture, risk associated with developing renewable fuels, consumer information gaps, and lack of quantification of the non-economic costs and benefits of both renewable and fossil-based fuels. This report focuses on renewable fuel standards policies, which are being analyzed as part of this project.

  6. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo......An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  7. State Clean Energy Practices: Renewable Portfolio Standards

    Energy Technology Data Exchange (ETDEWEB)

    Hurlbut, D.

    2008-07-01

    The State Clean Energy Policies Analysis (SCEPA) project is supported by the Weatherization and Intergovernmental Program within the Department of Energy's Office of Energy Efficiency and Renewable Energy. This project seeks to quantify the impacts of existing state policies, and to identify crucial policy attributes and their potential applicability to other states. The goal is to assist states in determining which clean energy policies or policy portfolios will best accomplish their environmental, economic, and security goals. For example, a renewable portfolio standard (RPS) mandates an increase in the use of wind, solar, biomass, and other alternatives to fossil and nuclear electric generation. This paper provides a summary of the policy objectives that commonly drive the establishment of an RPS, the key issues that states have encountered in implementing an RPS, and the strategies that some of the leading states have followed to address implementation challenges. The factors that help an RPS function best generally have been explored in other analyses. This study complements others by comparing empirical outcomes, and identifying the policies that appear to have the greatest impact on results.

  8. Risk Management Programs under Clean Air Act Section 112(r): Guidance for Implementing Agencies

    Science.gov (United States)

    Accidental release prevention programs under section 112(r) of the Clean Air Act (CAA) are related to and build on activities under the Emergency Planning and Community Right-to-Know Act, and Occupational Safety and Health Administration standards.

  9. 77 FR 44672 - Notice of Lodging of Consent Decree Under the Clean Water and Clean Air Acts

    Science.gov (United States)

    2012-07-30

    ... of Lodging of Consent Decree Under the Clean Water and Clean Air Acts Notice is hereby given that on... resolve its violations of the Clean Air Act and the Clean Water Act. The Allegheny County Health... the Clean Water Act, Plaintiffs allege that Shenango violated the effluent limitations in the...

  10. 17th DOE nuclear air cleaning conference: proceedings. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1983-02-01

    Volume 2 contains papers presented at the following sessions: adsorption; noble gas treatment; personnel education and training; filtration and filter testing; measurement and instrumentation; air cleaning equipment response to accident related stress; containment venting air cleaning; and an open end session. Twenty-eight papers were indexed separately for inclusion in the Energy Data Base. Ten papers had been entered earlier.

  11. Air cleaning issues with contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Bellamy, R.R. [Nuclear Regulatory Commission, King of Prussia, PA (United States)

    1997-08-01

    The US Nuclear Regulatory Commission has developed a list of contaminated sites that warrant special USNRC attention because they pose unique or complex decommissioning issues. This list of radiologically contaminated sites is termed the Site Decommissioning Management Plan (SDMP), and was first issued in 1990. A site is placed on the SDMP list if it has; (1) Problems with the viability of the responsible organization (e.g., the licensee for the site is unable or unwilling to pay for the decommissioning); (2) Large amounts of soil contamination or unused settling ponds or burial grounds that may make the waste difficult to dispose of; (3) The long-term presence of contaminated, unused buildings; (4) A previously terminated license; or (5) Contaminated or potential contamination of the ground water from on-site wastes. In deciding whether to add a site to the SDMP list, the NRC also considers the projected length of time for decommissioning and the willingness of the responsible organization to complete the decommissioning in a timely manner. Since the list was established, 9 sites have been removed from the list, and the current SDMP list contains 47 sites in 11 states. The USNRC annually publishes NUREG-1444, {open_quotes}Site Decommissioning Management Plan{close_quotes}, which updates the status of each site. This paper will discuss the philosophical goals of the SDMP, then will concentrate on the regulatory requirements associated with air cleaning issues at the SDMP sites during characterization and remediation. Both effluent and worker protection issues will be discussed. For effluents, the source terms at sites will be characterized, and measurement techniques will be presented. Off-site dose impacts will be included. For worker protection issues, air sampling analyses will be presented in order to show how the workers are adequately protected and their doses measured to satisfy regulatory criteria during decontamination operations. 1 tab.

  12. 75 FR 11560 - Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act

    Science.gov (United States)

    2010-03-11

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act Notice is hereby given that... violations of the Clean Water Act, 33 U.S.C. 1251 et seq., and the Clean Air Act, 42 U.S.C. 7401 et seq....

  13. Proceedings of the fifteenth DOE nuclear air cleaning conference

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1979-02-01

    Papers presented are grouped under the following topics: noble gas separation, damage control, aerosols, test methods, new air cleaning technology from Europe, open-end, and filtration. A separate abstract was prepared for each paper.

  14. EnviroAtlas - Clean Air Metrics for Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas web service supports research and online mapping activities related to EnviroAtlas (https://www.epa.gov/enviroatlas). The Clean Air category in this...

  15. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  16. Food-Growing, Air- And Water-Cleaning Module

    Science.gov (United States)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  17. Prototype air cleaning system for a firing range

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, J.A.; Mishima, J.; Bamberger, J.A.

    1985-01-01

    This report recommends air cleaning system components for the US Army Ballistics Research Laboratory's new large-caliber firing range, which is used for testing depleted uranium (DU) penetrators. The new air cleaning system has lower operating costs during the life of the system compared to that anticipated for the existing air cleaning system. The existing system consists of three banks of filters in series; the first two banks are prefilters and the last are high-efficiency particulate air (HEPA) filters. The principal disadvantage of the existing filters is that they are not cleanable and reusable. Pacific Northwest Laboratory focused the search for alternate air cleaning equipment on devices that do not employ liquids as part of the particle collection mechanism. Collected dry particles were assumed preferable to a liquid waste stream. The dry particle collection devices identified included electrostatic precipitators; inertial separators using turning vanes or cyclones; and several devices employing a filter medium such as baghouses, cartridge houses, cleanable filters, and noncleanable filters similar to those in the existing system. The economics of practical air cleaning systems employing the dry particle collection devices were evaluated in 294 different combinations. 7 references, 21 figures, 78 tables.

  18. Fundamentals of air cleaning technology and its application in cleanrooms

    CERN Document Server

    Xu, Zhonglin

    2014-01-01

    Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms sets up the theoretical framework for cleanrooms. New ideas and methods are presented, which include the characteristic index of cleanrooms, uniform and non-uniform distribution characteristics, the minimum sampling volume, a new concept of outdoor air conditioning and the fundamentals of leakage-preventing layers. Written by an author who can look back on major scientific achievements and 50 years of experience in this field, this book offers a concise and accessible introduction to the fundamentals of air cleaning technology and its application. The work is intended for researchers, college teachers, graduates, designers, technicians and corporate R&D personnel in the field of HVAC and air cleaning technology. Zhonglin Xu is a senior research fellow at China Academy of Building Research.

  19. Ductless personalized ventilation with local air cleaning

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    was equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C. The pollution load in the room was simulated by PVC floor covering. The subjects assessed...

  20. Section 609 of the Clean Air Act: Motor Vehicle Air Conditioning

    Science.gov (United States)

    Fact sheet provides a general overview of EPA regulations under Section 609 of the Clean Air Act, which is focused on preventing the release of refrigerants during the servicing of motor vehicle air-conditioning systems and similar appliances.

  1. Self-Cleaning Particulate Air Filter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA requires an innovative solution to the serious issue of particulate fouling on air revitalization component surfaces in order to address the potential for...

  2. The Clean Air Act and the Economy

    Science.gov (United States)

    Since 1970, cleaner air and a growing economy have gone hand in hand. The Act has created market opportunities that have helped to inspire innovation in cleaner technologies for which the United States has become a global market leader.

  3. 76 FR 52275 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revisions to Clean Air...

    Science.gov (United States)

    2011-08-22

    ... to Clean Air Interstate Rule Emissions Trading Program AGENCY: Environmental Protection Agency (EPA... Commonwealth of Virginia. The revision, which amends the Virginia Clean Air Interstate Rule (CAIR) trading program, is comprised of technical corrections and revisions to the definition of a cogeneration unit to...

  4. Evaluation of various activated carbons for air cleaning - Towards design of immune and sustainable buildings

    Science.gov (United States)

    Haghighat, Fariborz; Lee, Chang-Seo; Pant, Bhuvan; Bolourani, Golnoush; Lakdawala, Ness; Bastani, Arash

    There are increased demands for security, sustainability and indoor air quality in today's building design, construction, operation and maintenance. Installation of air cleaning systems can improve the indoor air quality by reducing the air pollution levels, and enhance the building security against sudden release of chemical and/or biological agents. At the same time, air cleaning techniques may reduce the building energy consumption by reducing the outdoor air supply rate, hence lowering the needs for conditioning of outdoor air. While the air filtration of particulate matter is well standardized, the standards against which the performance of air cleaning for gaseous contaminants is measured or classified are still under development. This study examined the performance of various granular activated carbons (GACs) for the removal of volatile organic compounds (VOCs) from mechanically ventilated buildings. Eight different GACs (three virgin and five impregnated) were tested against toluene using a dynamic test system. The virgin GACs showed better performance than impregnated ones, the percentage and the type of impregnation affected the removal efficiencies. Tests were also conducted with selected GACs against toluene, cyclohexane and ethyl acetate at relative humidity (RH) values of 30%, 50% and 70%. The effect of humidity was dependant on the VOC used. Both for toluene and cyclohexane, the removal efficiency decreased as RH increased. However, higher humidity showed a positive impact on the removal of ethyl acetate.

  5. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    DEFF Research Database (Denmark)

    Nazaroff, W.; Weschler, Charles J.

    2004-01-01

    . More than two dozen research articles present evidence of adverse health effects from inhalation exposure associated with cleaning or cleaning products. Exposure to primary and secondary pollutants depends on the complex interplay of many sets of factors and processes, including cleaning product...... by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals...... that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which...

  6. New challenges to air/gas cleaning systems

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, J.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    This paper discusses the need for changes in the design and manufacturing of air and gas cleaning systems to meet waste management and site remediation requirements. Current design and manufacturing practices are primarily directed toward evaluating operational problems with existing systems in nuclear reactor facilities. However, nuclear waste management needs have developed which are much broader in scope and have different processing conditions. Numerous examples of air cleaning needs for waste management activities are provided; the major differences from operating facility needs are the requirement for continuous effluent treatment under widely different processing conditions. Related regulatory issues are also discussed briefly. 1 ref.

  7. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    Science.gov (United States)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo; Sundell, Jan; Wargocki, Pawel; Zhang, Jensen; Little, John C.; Corsi, Richard; Deng, Qihong; Leung, Michael H. K.; Fang, Lei; Chen, Wenhao; Li, Jinguang; Sun, Yuexia

    2011-08-01

    comparing the performance of different air cleaning technologies. (4) To compare and select suitable indoor air cleaning devices, a labeling system accounting for characteristics such as CADR, energy consumption, volume, harmful by-products, and life span is necessary. For that purpose, a standard test room and condition should be built and studied. (5) Although there is evidence that some air cleaning technologies improve indoor air quality, further research is needed before any of them can be confidently recommended for use in indoor environments.

  8. Clean air litigation; Klagen fuer Saubere Luft

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-11-11

    The pollution of air by nitrogen dioxide (NO{sub 2}) in cities is one of the central challenges of air pollution in Germany, in addition to the pollution of particulate matter (PM10). In cooperation with the British non-governmental organization ClientEarth, the German Environmental Aid (DUH) filed a lawsuit in November 2015 for exceeding air quality limits for NO{sub 2}. The cities of Stuttgart, Frankfurt, Duesseldorf, Essen, Gelsenkirchen, Aachen, Cologne and Bonn are affected. Here, citizens are constantly exposed to high air pollution. Because of the excess of the NO{sub 2} limits at all traffic-related measuring stations in Berlin, the DUH initiated legal steps and filed a lawsuit too in June 2016. With the lawsuits, DUH wants to promote the implementation of measures to reduce NO{sub 2} in Germany. [German] Die Belastung der Luft durch Stickstoffdioxid (NO{sub 2}) in Staedten ist neben der Belastung durch Feinstaub (PM10) eine der zentralen Herausforderungen der Luftreinhaltung in Deutschland. In Zusammenarbeit mit der britischen Nichtregierungsorganisation ClientEarth legte die Deutsche Umwelthilfe (DUH) im November 2015 Klage wegen Ueberschreitung der Luftqualitaetsgrenzwerte fuer NO{sub 2}ein. Betroffen sind die Staedte Stuttgart, Frankfurt, Duesseldorf, Essen, Gelsenkirchen, Aachen, Koeln und Bonn. Hier sind Buergerinnen und Buerger anhaltend zu hoher Luftverschmutzung ausgesetzt. Wegen Ueberschreitung der NO{sub 2}-Grenzwerte an allen verkehrsnahen Messstationen in Berlin hat die DUH im Juni 2016 auch hier rechtliche Schritte eingeleitet und Klage eingereicht. Mit den Klagen will die DUH die Umsetzung von Massnahmen zur NO{sub 2}-Reduktion in Deutschland voranbringen.

  9. Rationing health protection: a proposal to exempt nuisance dust from US Clean Air Act regulations.

    Science.gov (United States)

    Centner, Terence J; Colson, Gregory

    2013-03-15

    The US House of Representative has passed a bill called the "Farm Dust Regulation Prevention Act" (Dust Act) that would exempt most types of particulate matter (PM) in rural areas from the air quality controls of the US Clean Air Act. The Dust Act would markedly change the country's air quality standards. An examination of the proposed provisions shows that they would exempt non-combustion PM pollutants from mining, smelting, petroleum production, and power generation from existing air quality standards. Persons downwind from pollutants generated in rural areas could be exposed to concentrations of carcinogenic heavy metals, asbestos, and benzene known to adversely affect their health and ecological resources. Existing federal air quality standards based on science would be replaced by a flexible standard that rations health protection.

  10. Evaluation of air cleaning technologies existing in the Danish market

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2014-01-01

    the ozone level significantly in the room. Moreover, they can cause generation of ultrafine particles and consequently increase ultrafine particle concentration in the room. The study suggests using a mechanical filter with low pressure drop as a recommended air cleaning technology in order to remove...

  11. Further developed filter systems for keeping the air clean

    Energy Technology Data Exchange (ETDEWEB)

    Hochstrat, W.B.

    1978-12-01

    The pulse-jet filter system is presented in this contribution. The development of improved fibers to produce high-quality needle felting was the basis for surface filters as well as tube filters. The system tube filter with pressurized-air cleaning is described in greater detail. Its advantage besides good degrees of separation is especially the little maintenance required.

  12. Proceedings of the fifteenth DOE nuclear air cleaning conference

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1979-02-01

    Papers presented are grouped under the following topics: air cleaning; waste volume reduction and preparation for storage; tritium, carbon-14, ozone; containment of accidental releases; adsorbents and absorbents; and off-gas treatment. A separate abstract was prepared for each paper.

  13. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  14. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    Energy Technology Data Exchange (ETDEWEB)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M. [Brookhaven National Lab., Upton, NY (United States); Hemenway, A. [USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States)

    1991-12-31

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protection Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.

  15. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    Energy Technology Data Exchange (ETDEWEB)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M. (Brookhaven National Lab., Upton, NY (United States)); Hemenway, A. (USDOE Assistant Secretary for Fossil Energy, Washington, DC (United States))

    1991-01-01

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protection Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.

  16. Chapter 4: Assessing the Air Pollution, Greenhouse Gas, Air Quality, and Health Benefits of Clean Energy Initiatives

    Science.gov (United States)

    Chapter 4 of “Assessing the Multiple Benefits of Clean Energy” helps state energy, environmental, and economic policy makers assess the air quality, greenhouse gas, air pollution, and health benefits of clean energy initiatives.

  17. [Assessment of the air quality improment of cleaning and disinfection on central air-conditioning ventilation system].

    Science.gov (United States)

    Liu, Hongliang; Zhang, Lei; Feng, Lihong; Wang, Fei; Xue, Zhiming

    2009-09-01

    To assess the effect of air quality of cleaning and disinfection on central air-conditioning ventilation systems. 102 air-conditioning ventilation systems in 46 public facilities were sampled and investigated based on Hygienic assessment criterion of cleaning and disinfection of public central air-conditioning systems. Median dust volume decreased from 41.8 g/m2 to 0.4 g/m2, and the percentage of pipes meeting the national standard for dust decreased from 17.3% (13/60) to 100% (62/62). In the dust, median aerobic bacterial count decreased from 14 cfu/cm2 to 1 cfu/cm2. Median aerobic fungus count decreased from 10 cfu/cm2 to 0 cfu/cm2. The percentage of pipes with bacterial and fungus counts meeting the national standard increased from 92.4% (171/185) and 82.2% (152/185) to 99.4% (165/166) and 100% (166/166), respectively. In the ventilation air, median aerobic bacterial count decreased from 756 cfu/m3 to 229 cfu/m3. Median aerobic fungus count decreased from 382 cfu/m3 to 120 cfu/m3. The percentage of pipes meeting the national standard for ventilation air increased from 33.3% (81/243) and 62.1% (151/243) to 79.8% (292/366) and 87.7% (242/276), respectively. But PM10 rose from 0.060 mg/m3 to 0.068 mg/m3, and the percentage of pipes meeting the national standard for PM10 increased from 74.2% (13/60) to 90.2% (46/51). The cleaning and disinfection of central air-conditioning ventilation systems could have a beneficial effect of air quality.

  18. Proceedings of the 21st DOE/NRC nuclear air cleaning conference; Volume 2, Sessions 9--16

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. [ed.] [Harvard Univ., Boston, MA (United States). Harvard Air Cleaning Lab.

    1991-02-01

    The 21st meeting of the Department of Energy/Nuclear Regulatory Commission (DOE/NRC) Nuclear Air Cleaning Conference was held in San Diego, CA on August 13--16, 1990. The proceedings have been published as a two volume set. Volume 2 contains sessions covering adsorbents, nuclear codes and standards, modelling, filters, safety, containment venting and a review of nuclear air cleaning programs around the world. Also included is the list of attendees and an index of authors and speakers. (MHB)

  19. Is the perception of clean, humid air indeed affected by cooling the respiratory tract?

    Science.gov (United States)

    Burek, Rudolf; Polednik, Bernard; Guz, Łukasz

    2017-07-01

    The study aims at determining exposure-response relationships after short exposure to clean air and long exposure to air polluted by people. The impact of water vapor content in the indoor air on its acceptability (ACC) was assessed by the occupants after a short exposure to clean air and an hour-long exposure to increasingly polluted air. The study presents a critical analysis pertaining to the stimulation of olfactory sensations by the air enthalpy suggested in previous models and proposes a new model based on the Weber-Fechner law. Our assumption was that water vapor is the stimulus of olfactory sensations. The model was calibrated and verified in field conditions, in a mechanically ventilated and air conditioned auditorium. Measurements of the air temperature, relative humidity, velocity and CO2 content were carried out; the acceptability of air quality was assessed by 162 untrained students. The subjective assessments and the measurements of the environmental qualities allowed for determining the Weber coefficients and the threshold concentrations of water vapor, as well as for establishing the limitations of the model at short and long exposure to polluted indoor air. The results are in agreement with previous studies. The standard error equals 0.07 for immediate assessments and 0.17 for assessments after adaptation. Based on the model one can predict the ACC assessments of trained and untrained participants.

  20. Market Initiatives for Clean Air Schools; Marktinitiatieven frisse scholen

    Energy Technology Data Exchange (ETDEWEB)

    Teeuwen, D. [Communication Concert, Weesp (Netherlands)

    2012-07-15

    Seven years ago, the Clean Air Schools Program was launched to encourage people to use less energy and improve the indoor environment. In 2012, the program Energy and Built Environment will no longer pay specific attention focused on school buildings. Therefore, the market needs to jump in. 'Market initiatives' refers to projects, products and services that contribute to the realization of Clean Air Schools and which are not initiated by the Dutch government [Dutch] Zeven jaar geleden is het Frisse Scholen Programma gestart om gemeenten en scholen te stimuleren om minder energie te gebruiken en het binnenmilieu te verbeteren. In 2012 biedt het programma Energie en Gebouwde Omgeving geen ruimte meer voor specifieke aandacht gericht op scholen. Daarom zal het stokje overgedragen moeten worden aan marktpartijen. Met 'marktinitiatieven' wordt gedoeld op projecten, producten en diensten die bijdragen aan de realisatie van Frisse Scholen en niet door de Rijksoverheid worden geinitieerd.

  1. 40 CFR 2.301 - Special rules governing certain information obtained under the Clean Air Act.

    Science.gov (United States)

    2010-07-01

    ... information obtained under the Clean Air Act. 2.301 Section 2.301 Protection of Environment ENVIRONMENTAL... governing certain information obtained under the Clean Air Act. (a) Definitions. For the purpose of this section: (1) Act means the Clean Air Act, as amended, 42 U.S.C. 7401 et seq. (2)(i) Emission data...

  2. 76 FR 17671 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-03-30

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on March 21, 2011, a... this Clean Air Act enforcement action resolves allegations by the Environmental Protection Agency, asserted in a complaint filed together with the Consent Decree, under Section 113(b) of the Clean Air...

  3. 76 FR 66718 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2011-10-27

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  4. 75 FR 25855 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-05-10

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  5. 76 FR 9609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-02-18

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on February 14, 2011... Consent Decree in this Clean Air Act enforcement action resolves allegations by the Environmental... in a complaint filed together with the Consent Decree, under Section 113(b) of the Clean Air Act,...

  6. 77 FR 66462 - Clean Air Act Advisory Committee; Notice of Charter Renewal

    Science.gov (United States)

    2012-11-05

    ... AGENCY Clean Air Act Advisory Committee; Notice of Charter Renewal AGENCY: Environmental Protection...'s Clean Air Act Advisory committee (CAAAC) will be renewed for an additional two-year period, as a... recommendations to the EPA Administrator on policy issues associated with implementation of the Clean Air Act....

  7. 78 FR 9388 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-02-08

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... the Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  8. 75 FR 1379 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-01-11

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with ] implementation of the Clean Air Act of 1990. The...

  9. 75 FR 79369 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-12-20

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  10. 76 FR 9610 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-02-18

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on February 14, 2011... California. The Consent Decree in this Clean Air Act enforcement action resolves allegations by the...''), asserted in a complaint filed together with the Consent Decree, under Section 113(b) of the Clean Air...

  11. 78 FR 49511 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-08-14

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meeting of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on November... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  12. 78 FR 77448 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-12-23

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meetings of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  13. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  14. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    Science.gov (United States)

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology.

  15. A synthetic zero air standard

    Science.gov (United States)

    Pearce, Ruth

    2016-04-01

    A Synthetic Zero Air Standard R. E. Hill-Pearce, K. V. Resner, D. R. Worton, P. J. Brewer The National Physical Laboratory Teddington, Middlesex TW11 0LW UK We present work towards providing traceability for measurements of high impact greenhouse gases identified by the World Meteorological Organisation (WMO) as critical for global monitoring. Standards for these components are required with challengingly low uncertainties to improve the quality assurance and control processes used for the global networks to better assess climate trends. Currently the WMO compatibility goals require reference standards with uncertainties of < 100 nmolmol-1 for CO2 (northern hemisphere) and < 2 nmolmol-1 for CH4 and CO. High purity zero gas is required for both the balance gas in the preparation of reference standards and for baseline calibrations of instrumentation. Quantification of the amount fraction of the target components in the zero gas is a significant contributor to the uncertainty and is challenging due to limited availability of reference standard at the amount fraction of the measurand and limited analytical techniques with sufficient detection limits. A novel dilutor was used to blend NPL Primary Reference Gas Mixtures containing CO2, CH4 and CO at atmospheric amount fractions with a zero gas under test. Several mixtures were generated with nominal dilution ratios ranging from 2000:1 to 350:1. The baseline of two cavity ring down spectrometers was calibrated using the zero gas under test after purification by oxidative removal of CO and hydrocarbons to < 1 nmolmol-1 (SAES PS15-GC50) followed by the removal of CO2 and water vapour to < 100 pmolmol-1 (SAES MC190). Using the standard addition method.[1] we have quantified the amount fraction of CO, CO2, and CH4 in scrubbed whole air (Scott Marrin) and NPL synthetic zero air. This is the first synthetic zero air standard with a matrix of N2, O2 and Ar closely matching ambient composition with gravimetrically assigned

  16. Time to harmonize national ambient air quality standards.

    Science.gov (United States)

    Kutlar Joss, Meltem; Eeftens, Marloes; Gintowt, Emily; Kappeler, Ron; Künzli, Nino

    2017-05-01

    The World Health Organization has developed ambient air quality guidelines at levels considered to be safe or of acceptable risk for human health. These guidelines are meant to support governments in defining national standards. It is unclear how they are followed. We compiled an inventory of ambient air quality standards for 194 countries worldwide for six air pollutants: PM2.5, PM10, ozone, nitrogen dioxide, sulphur dioxide and carbon monoxide. We conducted literature and internet searches and asked country representatives about national ambient air quality standards. We found information on 170 countries including 57 countries that did not set any air quality standards. Levels varied greatly by country and by pollutant. Ambient air quality standards for PM2.5, PM10 and SO2 poorly complied with WHO guideline values. The agreement was higher for CO, SO2 (10-min averaging time) and NO2. Regulatory differences mirror the differences in air quality and the related burden of disease around the globe. Governments worldwide should adopt science based air quality standards and clean air management plans to continuously improve air quality locally, nationally, and globally.

  17. Proceedings of the clean air and climate change summit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The Clean Air Partnership was established in the Greater Toronto Area (GTA) over 10 years ago to work on issues related to air pollution and climate change. This summit presented details of the partnership's municipal activities and provided an outline of various projects conducted to reduce air pollution, increase the use of green energy, and encourage residents to reduce their ecological footprint. Climate change was discussed in relation to the recent economic crisis and recently discovered problems related to ocean acidification. The International Energy Agency (IEA) annual report was discussed in relation to peak oil and future economic crises. Advancements in green energy policy in Ontario were outlined. Sustainable housing and renewable energy projects in Germany were presented along with successful urban designs in Melbourne, New York City, and Denver. The GTA-CAC inter-governmental declaration on clean air was discussed, and an interim progress report was presented. The summit concluded with a video presentation of a collaborative artistic piece about climate change and the Arctic. 11 figs.

  18. Effects of the 1990 Clean Air Act Amendments

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, D.A.

    1992-12-31

    At Argonne National Laboratory, we have a great deal of interest in the coal resource and in Clean Coal Technology, CCT. We had helped to develop dry scrubbing technology and we are currently active in developing Integrated Gasification Combined Cycle (IGCC) and combined SO{sub 2} and NO{sub x} removal technologies. I have spent much of the last 10 years developing computer simulation models representing the impacts of environmental policies on electric utilities, the coal industry and the economy as a whole. This work has been sponsored by the National Acid Precipitation Assessment Program (NA.PAP), the US Departmentof Energy, the US Environmental Protection Agency and the Federal Reserve Bank. Today I will talk about the 1990 Clean Air Act Amendments (CAAA) which will affect the coal market. I will focus on the sulfur dioxide (SO{sub 2}) requirements and not nitrogen oxides (NO{sub x}) or other aspects of the CAAA regulations.

  19. Effects of the 1990 Clean Air Act Amendments

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, D.A.

    1992-01-01

    At Argonne National Laboratory, we have a great deal of interest in the coal resource and in Clean Coal Technology, CCT. We had helped to develop dry scrubbing technology and we are currently active in developing Integrated Gasification Combined Cycle (IGCC) and combined SO[sub 2] and NO[sub x] removal technologies. I have spent much of the last 10 years developing computer simulation models representing the impacts of environmental policies on electric utilities, the coal industry and the economy as a whole. This work has been sponsored by the National Acid Precipitation Assessment Program (NA.PAP), the US Departmentof Energy, the US Environmental Protection Agency and the Federal Reserve Bank. Today I will talk about the 1990 Clean Air Act Amendments (CAAA) which will affect the coal market. I will focus on the sulfur dioxide (SO[sub 2]) requirements and not nitrogen oxides (NO[sub x]) or other aspects of the CAAA regulations.

  20. An introduction to the design, commissioning and operation of nuclear air cleaning systems for Qinshan Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Xinliang Chen; Jiangang Qu; Minqi Shi [Shanghai Nuclear Engineering Research and Design Institute (China)] [and others

    1995-02-01

    This paper introduces the design evolution, system schemes and design and construction of main nuclear air cleaning components such as HEPA filter, charcoal adsorber and concrete housing etc. for Qinshan 300MW PWR Nuclear Power Plant (QNPP), the first indigenously designed and constructed nuclear power plant in China. The field test results and in-service test results, since the air cleaning systems were put into operation 18 months ago, are presented and evaluated. These results demonstrate that the design and construction of the air cleaning systems and equipment manufacturing for QNPP are successful and the American codes and standards invoked in design, construction and testing of nuclear air cleaning systems for QNPP are applicable in China. The paper explains that the leakage rate of concrete air cleaning housings can also be assured if sealing measures are taken properly and embedded parts are designed carefully in the penetration areas of the housing and that the uniformity of the airflow distribution upstream the HEPA filters can be achieved generally no matter how inlet and outlet ducts of air cleaning unit are arranged.

  1. Investigation of air cleaning system response to accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Andrae, R.W.; Bolstad, J.W.; Foster, R.D.; Gregory, W.S.; Horak, H.L.; Idar, E.S.; Martin, R.A.; Ricketts, C.I.; Smith, P.R.; Tang, P.K.

    1980-01-01

    Air cleaning system response to the stress of accident conditions are being investigated. A program overview and hghlight recent results of our investigation are presented. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. The test facilities used to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components are described. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported.

  2. Path instabilities of air bubbles rising in clean water

    CERN Document Server

    Wu, M; Wu, Mingming; Gharib, Moteza

    1998-01-01

    Experiments are conducted to study the path and shape of single air bubbles (diameter range 0.10- 0.20cm) rising freely in clean water. The experimental results demonstrate that the bubble shape has a bistable state, i. e. the bubble chooses to be in spherical or ellipsoidal shape depending on its generation mechanism. The path of a spherical/ellipsoidal bubble is found to change from a straight path to a zigzag/spiral path via a supercritical/subcritical bifurcation when the Reynolds number of the bubble exceeds a threshold.

  3. Pure Air`s advanced flue gas desulfurization clean coal project

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J.R. [Pure Air Bailly Station, Chesterton, IN (United States)

    1998-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project successfully completed four and a half years of operation in December 1996 at Northern Indiana Public Service Company`s (NIPSCO) Bailly Generating Station. This project received a $60 million grant from the DOE Clean Coal II program. Included in this was a three year DOE demonstration period. The facility was designed, built and is owned and operated by Pure Air of Allentown, Pennsylvania, through its project company, Pure Air on the Lake, Limited Partnership. The project met or exceeded all performance criteria. It has averaged 95.3% SO{sub 2} removal, 99.9% availability and produced high quality commercial gypsum during this four and a half year period. It demonstrated many advanced technology features including a single, large absorber module serving two boilers, a wastewater evaporation system, an air rotary sparger for oxidation, and a new technology for agglomerating gypsum.

  4. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...

  5. 75 FR 34673 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Science.gov (United States)

    2010-06-18

    ...'') request for approval to implement and enforce Air Pollution Control Regulation Number 36, Control of Emissions from Organic Solvent Cleaning (``RI Regulation No. 36'') and Rhode Island Air Pollution Control.... Ira W. Leighton, Acting Regional Administrator, EPA New England. BILLING CODE 6560-50-P...

  6. 76 FR 30600 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revisions to Clean Air...

    Science.gov (United States)

    2011-05-26

    ... (CAIR) trading program, is comprised of technical corrections and revisions to the definition of a cogeneration unit to ensure the Commonwealth's CAIR trading program is consistent with Federal CAIR... to Clean Air Interstate Rule Emissions Trading Program AGENCY: Environmental Protection Agency (EPA...

  7. Cleaning practices and cleaning products in nurseries and schools: to what extent can they impact indoor air quality?

    Science.gov (United States)

    Wei, W; Boumier, J; Wyart, G; Ramalho, O; Mandin, C

    2016-08-01

    In the framework of a nationwide survey on indoor air quality conducted from September 2009 to June 2011 in 310 nurseries, kindergartens, and elementary schools in all regions of France, cleaning practices and products were described through an extensive questionnaire completed on-site by expert building inspectors. The questionnaire included the cleaning frequencies and periods, cleaning techniques, whether windows were open during cleaning, and the commercial names of the products used. Analysis of the questionnaire responses showed that cleaning was generally performed daily for furniture and floors. It was performed mostly in the evening with wet mopping and with one or more windows open. Five hundred eighty-four different cleaning products were listed, among which 218 safety data sheets (SDSs) were available and analyzed. One hundred fifty-two chemical substances were identified in the SDSs. The typical substances in cleaning products included alcohols, chlorides, terpenes, aldehydes, and ethers; more than half of them are irritants. Two endocrine disruptors, 2-phenylphenol and Galaxolide, were identified in two cleaning products used every day to clean the floors, in seven kindergartens and in a nursery respectively. Eleven reactive substances containing C=C double bonds, mostly terpenes, were identified in a wide variety of cleaning products.

  8. Chicago Clean Air, Clean Water Project: Environmental Monitoring for a Healthy, Sustainable Urban Future

    Energy Technology Data Exchange (ETDEWEB)

    none, none; Tuchman, Nancy [Institute of Environmental Sustainability (IES), Chicago, IL (United States)

    2015-11-11

    The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has been launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.

  9. Clean Air for London (CLEARFLO) Final Campaign Summary

    Energy Technology Data Exchange (ETDEWEB)

    Worsnop, D. R. [Aerodyne Research, Inc., Billerica, MA (United States); Williams, L. R. [Aerodyne Research, Inc., Billerica, MA (United States); Herndon, S. C. [Aerodyne Research, Inc., Billerica, MA (United States); Dubey, M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ng, N. L. [Georgia Inst. of Technology, Atlanta, GA (United States); Thornton, J. [Univ. of Washington, Seattle, WA (United States); Knighton, B. [Montana State Univ., Bozeman, MT (United States); Coulter, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Prévôt, Ash [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    2016-03-01

    This field campaign funded the participation of scientists from seven different research groups and operated over thirty instruments during the Winter Intensive Operating Period (January-February 2012) of the Clean Air for London (ClearfLo) campaign. The campaign took place at a rural site in Detling, UK, 45 kilometers southeast of central London. The primary science questions for the ClearfLo winter IOP (intensive operational periods) were: 1) “what is the urban increment of particulate matter (PM) and other pollutants in the greater London area?” and 2) “what is the contribution of solid fuel use for home heating to wintertime PM?” An additional motivation for the Detling measurements was the question of whether coatings on black carbon particles enhance absorption.

  10. Citizen Science Air Sensor Project with Clean Air Carolina and the Eastern Band of Cherokee Indians Fact Sheet

    Science.gov (United States)

    EPA scientists are partnering with Clean Air Carolina (CAC) in Charlotte, N.C., and the Eastern Band of Cherokee Indians (EBCI) in Cherokee, N.C., to conduct a citizen science air quality project in these regions.

  11. A review of potential alternatives for air cleaning at the Hanford Waste Vitrification Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sehmel, G.A.

    1990-07-01

    Pacific Northwest Laboratory conducted this review in support of the Hanford Waste Vitrification Plant (HWVP) being designed by Fluor Daniel Inc. for the US Department of Energy (DOE). The literature on air cleaning systems is reviewed to identify potential air cleaning alternatives that might be included in the design of HWVP. An overview of advantages/disadvantages of the various air cleaning technologies follows. Information and references are presented for the following potential air cleaning alternatives: deep-bed glass-fiber filters (DBGF), high-efficiency particulate air filters (HEPA), remote modular filter systems, high-efficiency mist eliminators (HEME), electrostatic precipitators, and the sand filter. Selected information is summarized for systems in the United States, Belgium, Japan, and West Germany. This review addresses high-capacity air cleaning systems currently used in the nuclear industry and emphasizes recent developments. 10 refs., 9 figs., 3 tabs.

  12. Interaction between Titles 2 and 3 of the Clean Air Act as amended, 1990

    Energy Technology Data Exchange (ETDEWEB)

    Szpunar, C.B.

    1996-02-01

    This report examines Some issues that would I affect the refining industry if the requirements for hazardous air pollutants set out in Title III of the Clean Air Act Amendments were to impede the market entrance of oxygenated fuels, as me; required by Title II. It describes the mandate for reformulated gasoline; considers gasoline characteristics in light of component shifts in refining; examines the supply of, demand for, and cost of various feedstocks and blendstocks; and identifies the emissions and atmospheric impacts that might result from the production and use of reformulated gasoline. Attention is focused on methanol and MTBE, two potential blendstocks that are also hazardous air pollutants, and on maximum achievable control technology standards, which might be applied to the stationary sources that produce them.

  13. In pursuit of clean air: a data book of problems and strategies at the state level. Supplement

    Energy Technology Data Exchange (ETDEWEB)

    Garvey, D.B.; Moser, S.B.; Streets, D.G.

    1980-08-01

    The Clean Air Act Amendments of 1977 and EPA regulations set stringent requirements for the control of emissions in areas where the National Ambient Air Quality Standards were being exceeded. This supplement updates a previous five-volume summary of nonattainment area designations and attainment strategies of the states as of July 1, 1980. It also contains maps of PSD Class I areas and additional information on coal production, coal reserves, and coal quality.

  14. An evaluation of hospital cleaning regimes and standards.

    Science.gov (United States)

    Griffith, C J; Cooper, R A; Gilmore, J; Davies, C; Lewis, M

    2000-05-01

    A four-part study assessing cleanliness in up to 113 environmental surfaces in an operating theatre and a hospital ward is reported. Surfaces were assessed visually, using microbiological methods and ATP bioluminescence. Results from a preliminary random survey indicated variability in cleanliness. These results were then used to select sites for monitoring before and after routine cleaning, over a 14-day period. Using published microbiological and ATP specifications 70 and 76% of these sites were unacceptable after cleaning. Visual assessment was a poor indicator of cleaning efficacy with only 18% considered unacceptable. Sites most likely to fail in the ward were in the toilet and kitchen, areas which are frequently implicated in the spread of infectious intestinal disease. Operating theatre sites had lower ATP results but 61% of sites would be considered unacceptable. There was no significant difference in general microbiological or ATP results overall before and after routine cleaning. Although some important hand contact sites showed no significant difference, overall there was a significant decrease in staphylococcal and enterobacteria counts in the ward but not in the operating theatre after cleaning. The routine cleaning programmes used did not include a biocide and cleaning using a hypochlorite based sanitizer gave much lower values. The results are discussed in relation to infection control, cleaning audits and cleaning schedules: an integrated cleaning monitoring programme using ATP bioluminescence in conjunction with visual and microbiological assessments is recommended.

  15. No Need to Wait for the Clean Air Dividend

    Science.gov (United States)

    Shindell, Drew

    2012-01-01

    Controlling smog and soot is the classic win-win situation, so it's great that the world is finally waking up to the idea. WHAT if there was a way to simultaneously slow down climate change, save millions of lives, improve crop yields and contribute to sustainable development and energy security? It sounds too good to be true, but it is possible. It won't be free or easy, but with some effort and moderate investment, it can be done. The way to do it is to reduce emissions leading to two types of pollution: black carbon and ozone. These are the only pollutants that we know contribute to both global warming and poor air quality. Black carbon is essentially soot, emitted from incomplete combustion of fossil fuels and biomass. It warms the climate in two ways: by absorbing heat in the atmosphere - similar to the greenhouse effect - and by reducing Earth's albedo, or ability to reflect sunlight. Inhaled into the lungs, it leads to cancer and cardiovascular disease. Ozone in the atmosphere also acts as a greenhouse gas, while ground-level ozone is toxic to humans and plants, so leads to both premature death and reduced crop yields. Ozone is not emitted directly but is produced by the action of sunlight on other pollutants, which are known as ozone precursors. Since black carbon and ozone are important components of soot and smog, a great deal of effort has already been put into developing methods to reduce emissions. So effective technology is available, but needs wider implementation. The recommended control measures for black carbon include widespread and tight emission standards on diesel cars and trucks; improved solid fuel cooking stoves, brick kilns and coke ovens in the developing world; and a ban on the open burning of agricultural waste. Implementation of these measures would have a rapid impact on the climate and human health, and also have the added benefit of greatly reducing emissions of carbon monoxide, an important ozone precursor. A second key ozone

  16. Saving energy and improving IAQ through application of advanced air cleaning technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J; Destaillats, H.; Sidheswaran, M.A.

    2011-03-01

    In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

  17. 76 FR 5609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-02-01

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on January 26, 2011, a... United States et al. v. HOVENSA L.L.C., Civil Action No. 1:11-cv-6. The Consent Decree in this Clean Air... Agency, asserted in a complaint filed together with the Consent Decree, under section 113(b) of the...

  18. 75 FR 61774 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2010-10-06

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on September 28, 2010... Consent Decree in this Clean Air Act enforcement actions against Murphy Oil USA, Inc. (``Murphy... Louisiana asserted in a complaint filed together with the Consent Decree, under Section 113(b) of the...

  19. 40 CFR 23.3 - Timing of Administrator's action under Clean Air Act.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Timing of Administrator's action under Clean Air Act. 23.3 Section 23.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL JUDICIAL REVIEW UNDER EPA-ADMINISTERED STATUTES § 23.3 Timing of Administrator's action under Clean Air...

  20. 75 FR 74046 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-11-30

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``Act''), 42 U.S.C. 7413(g), notice is hereby given of a... Colorado doing business as Xcel Energy to operate the Pawnee coal-fired power plant in Morgan...

  1. 75 FR 20863 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2010-04-21

    ... of Lodging of Consent Decree Under the Clean Air Act Notice is hereby given that on April 16, 2010, a... complaint filed together with the Consent Decree that Defendants violated the Clean Air Act and regulations... bringing storage tanks and loading racks at their bulk gasoline terminals into compliance with the NSPS...

  2. 77 FR 5010 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-02-01

    ... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g... shall jointly file a stipulation of dismissal with prejudice with the court, within 10 days of the...

  3. 77 FR 45605 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-08-01

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice is... with prejudice. For a period of thirty (30) days following the date of publication of this notice,...

  4. 76 FR 75545 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-12-02

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), notice is... request to the Court to dismiss this matter with prejudice. For a period of thirty (30) days following...

  5. 77 FR 14785 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-03-13

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), 42 U.S.C. 7413(g), notice is hereby given of a... would then dismiss the case with prejudice once EPA has fulfilled these obligations under the...

  6. 78 FR 30919 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-05-23

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), notice is hereby given of a... shall be terminated and the case dismissed with prejudice. For a period of thirty (30) days...

  7. 76 FR 17416 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-03-29

    ... AGENCY Proposed Settlement Agreement, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency... accordance with section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 42 U.S.C. 7413(g... dismiss this suit with prejudice. For a period of thirty (30) days following the date of publication...

  8. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et...

  9. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  10. Implementation of the clean air strategy for Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Sandhu, H.S.; Angle, R.P. [Alberta Dept. of Environmental Protection, Alberta (Canada); Kelly, M. [Clean Air Strategic Alliance, Alberta (Canada)

    1995-12-31

    Air quality and its effects on the environment and human health have received considerable attention during the last three decades in Alberta, Canada. Among the issues receiving a high priority are acid deposition, smog and global warming. There are various sources of emissions to Alberta`s atmosphere, many of which relate to the extraction, processing, and burning of fossil fuels; pulp and paper manufacture; and transportation. There are also natural sources of contaminants, such as particulates from forest fires and methane from bogs. The extraction, processing and combustion of fossil fuels play an important role in Alberta`s economy. The province produces over 80 % of the oil and natural gas in Canada, and nearly half the coal. Low sulphur coal is used in power plants to supply more than 90 % of the electricity used in this province by nearly three million people. As a result, Alberta is responsible for about 27 % of the CO{sub 2}, 23 % of the nitrogen oxides, and 16 % of the SO{sub 2} emissions generated in Canada. Alberta`s air quality is monitored by the Government of Alberta at nine continuous, eight intermittent, over 250 static, and 12 precipitation monitoring stations. Parameters such as carbon monoxide, oxides of nitrogen, sulphur dioxide, particulates, and ion-content of precipitation are measured. Industry operates a large number of ambient and static SO{sub 2} and H{sub 2}S monitoring stations across Alberta, with monitoring costs estimated at 56-80 million USD annually. The unique features of the Clean Air Strategy for Alberta (CASA) have already been published elsewhere. This presentation discusses the mechanism and progress on its implementation. (author)

  11. CLEAN-AIR heat pump. Reduced energy consumption for ventilation in buildings by integrating air cleaning and heat pump. Final Report; CLEAN-AIR heat pump - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Fang, L.; Olesen, Bjarne W.; Molinaro, G.; Simmonsen, P.; Skocajic, S. [Danmarks Tekniske Univ. Institut for Byggeri og Anlaeg, Lyngby (Denmark); Hummelshoej, R.M.; Carlassara, L. [COWI A/S, Lyngby, (Denmark); Groenbaek, H.; Hansen, Ole R. [Exhausto A/S, Langeskov (Denmark)

    2011-07-01

    This report summarizes task 1 of the Clean Air Heat Pump project - modelling and simulation on energy savings when using the clean air heat pump for ventilation, air cleaning and energy recovery. The total energy consumption of the proposed ventilation systems using clean air heat pump technology was calculated by a theoretical model and compared with the reference ventilation systems (conventional ventilation systems). The energy compared between the two systems includes energy used for heating, cooling and fan. The simulation and energy saving calculation was made for the application of the clean air heat pump in three typical climate conditions, i.e. mild-cold, mild-hot and hot and wet climates. Real climate data recorded from three cities in 2002 was used for the calculation. The three cities were Copenhagen (Denmark), Milan (Italy) and Colombo (Sir Lanka) which represent the above three typical climate zones. For the Danish climate (the mild cold climate), the calculations show that the ventilation system using clean air heat pump technology can save up to 42% of energy cost in winter compared to the conventional ventilation system. The energy saving in summer can be as high as 66% for the ventilation system with humidity control and 9% for the ventilation system without the requirement of humidity control. Since the Danish summer climate is very mild, over 80% of the yearly energy consumption for ventilation is used during winter season. It is, therefore, estimated that more than 35% annual energy saving for ventilation is expected in Denmark using the clean air heat pump ventilation technology. For the mild hot climate, e.g. the Italian climate, the calculations show that up to 63% of the energy saving can be achieved in summer season. For the winter mode, 17% reduction of the energy cost can be expected for the domestic use. For industrial use, the energy cost of the clean air heat pump may not be favourable due to the industrial price of gas in Italy is

  12. Evaluating The Operation Of Three Air Cleaners Working Individually In A Clean Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2011-01-01

    The use of portable air cleaners is becoming increasingly popular in many countries including Denmark. Portable air cleaners are known for not only removing but also generating particles and gases. To clarify this, three air cleaning technologies were evaluated. They were nonthermal plasma......, photochemical air purifier and corona discharge ionizer. The concentrations of ultrafine particles, ozone and total volatile organic compounds were measured both in a duct and in a clean room. It was found that the studied air cleaning technologies increased the ozone level in the clean room and the duct....... The increase of ozone level in the clean room was more than that was measured in the duct. Additionally, it was found that the number of ultrafine particles in the room increased due to the generated ozone. The number of generated particles changed with the season. The study leads to the recommendation...

  13. Energy efficient biological air cleaning for farm stable ventilation; Energieffektiv biologisk luftrensning til staldventilation

    Energy Technology Data Exchange (ETDEWEB)

    Groenborg Nicolaisen, C.; Hansen, Mads P.R. [Teknologisk Institut, Aarhus (Denmark); Stroem, J.; Soerensen, Keld [DXT. Danish Exergy Technology A/S, Skoerping (Denmark); Goetke, C. [Lokalenergi Aarhus, Viby J. (Denmark); Morsing, S.; Soerensen, Lars C. [SKOV A/S, Roslev (Denmark); Ladegaerd Jensen, T.; Pedersen, Poul [Videncenter for svineproduktion, Copenhagen (Denmark)

    2013-05-01

    The project has been designed to reduce energy consumption for air purification by 30% while having a payback period of maximum 3 years. The project has achieved very significant results which are far above the target. Particularly satisfying is the wide range of new components that are launched in late 2012. By implementing the newly developed system at 100% cleaning (LPC 13 ventilators and Dynamic multistep control) in relation to Best Practice (SKOV's original system with DA600 fans) in a concrete pigsty, a saving of 61% and a simple payback of 1.7 years is achieved. Similarly, it is found that the energy used for pump operation can be reduced by 37% with the new Dynamic sprinkling control. At 20% cleaning a potential saving of 15% per year and a payback period of between 0 and 5 years was found, which is dependent on the desired performance as the capacities in the bio-filter's upper capacity range between 26 thousand to 30 thousand m3 / h entails costs for an additional extraction unit in the new solution. Furthermore, the newly developed components proved highly suitable for standard installations without air cleaning where a savings potential is 53% and the payback period 1.5 years. Product-wise, the project formed the basis for the development of: 1. New energy-efficient ventilation units (LPC11, 12,13) that are suitable for air purification; 2. A new energy-saving control principle (Dynamic Multi-Step) which is particularly suitable for low-energy ventilators; 3. A new energy-saving flow measurement system for ventilating ducts (Dynamic air to the central exhaust); 4. An energy-saving pressure control in common ducts (pressure control as a function of outside temperature); 5. Proposal for a new energy-saving pump operation for sprinkling of biological filters (Dynamic sprinkling). (LN)

  14. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R.H. [Trinity Consultants Incorporated, Dallas, TX (United States)

    1995-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  15. Pure Air`s Advanced Flue Gas Desulfurization Clean Coal Project

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J.R. [Pure Air Bailly Station, Chesterton, IN (United States)

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project successfully completed four and a half years of operation in December 1996 at Northern Indiana Public Service Company`s (NIPSCO) Bailly Generation Station. Included in this was a three year DOE demonstration period. The project was built by a joint venture company of Air Products and Chemicals, Inc. and Mitsubishi Heavy Industries America, Inc., utilizing Mitsubishi`s wet limestone flue gas desulfurization technology. The project met or exceeded all performance criteria. It has averaged 95.3% SO{sub 2} removal, 99.9% availability and produced 936,000 metric tons of high quality commercial gypsum during this four and a half year period. It demonstrated many advanced technology features including a single, large absorber module serving two boilers, a wastewater evaporation system, an air rotary sparger for oxidation, and a new technology for agglomerating gypsum. The AFGD system was designed, built, owned and operated by Pure Air and will continue to serve NIPSCO`s Bailly Station for at least another 15{1/2} years under an Own and Operate contract. The project enabled NIPSCO to cost effectively achieve full system wide compliance with the Phase 2 emission requirements for SO{sub 2} of the Clean Air Act Amendments (CAAA) of 1990 almost eight years before the target date. The project was the recipient of the Outstanding Engineering Achievement Award from the National Society of Professional Engineers in 1993 and the 1993 Powerplant Award from Power magazine. The data presented in this paper are based on performance during the first three years of operation.

  16. 3 CFR - State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act

    Science.gov (United States)

    2010-01-01

    ....C. 7543(b), the Clean Air Act Presidential Documents Other Presidential Documents Memorandum of January 26, 2009 State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act Memorandum for the Administrator of the Environmental Protection Agency Under the Clean Air Act (42...

  17. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Science.gov (United States)

    2010-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  18. Clean Power Plan Toolbox

    Science.gov (United States)

    These are resources to help states as they develop state implementation plans under section 111(d) of the Clean Air Act to meet EPA's carbon pollution standards for existing power plants. Supplements www2.epa.gov/carbon-pollution-standards.

  19. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    Science.gov (United States)

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  20. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  1. Keeping the Air Clean and Safe: An Anthrax Smoke Detector

    Science.gov (United States)

    2005-01-01

    Scientists at work in the Planetary Protection division at NASA s Jet Propulsion Laboratory (JPL) sterilize everything before blasting it to the Red Planet. They take great pains to ensure that all spacecraft are void of bacterial life, especially the microscopic bacteria that can live hundreds of years in their spore states. No one is quite sure what Earthly germs would do on Mars, but scientists agree that it is safest to keep the Martian terrain as undisturbed as possible. Errant Earth germs would also render useless the instruments placed on exploration rovers to look for signs of life, as the life that they registered would be life that came with them from Earth. A team at JPL, headed by Dr. Adrian Ponce, developed a bacterial spore-detection system that uses a simple and robust chemical reaction that visually alerts Planetary Protection crews. It is a simple air filter that traps micron-sized bacterial spores and then submits them to the chemical reaction. When the solution is then viewed under an ultraviolet light, the mixture will glow green if it is contaminated by bacteria. Scientists can then return to the scrubbing and cleaning stages of the sterilization process to remove these harmful bacteria. The detection system is the space-bound equivalent of having your hands checked for cleanliness before being allowed to the table; and although intended to keep terrestrial germs from space, this technology has awesome applications here on Mother Earth. The bacterial spore-detection unit can recognize anthrax and other harmful, spore-forming bacteria and alert people of the impending danger. As evidenced in the anthrax mailings of fall 2001 in the United States, the first sign of anthrax exposure was when people experienced flu-like symptoms, which unfortunately, can take as much as a week to develop after contamination. Anthrax cost 5 people their lives and infected 19 others; and the threat of bioterrorism became a routine concern, with new threats popping up

  2. 76 FR 28318 - National Emission Standards for Hazardous Air Pollutants From the Portland Cement Manufacturing...

    Science.gov (United States)

    2011-05-17

    ... the Portland Cement Manufacturing Industry and Standards of Performance for Portland Cement Plants... Pollutants emitted by the Portland Cement Industry and the New Source Performance Standards for Portland Cement Plants issued under sections 112(d) and 111(b) of the Clean Air Act, respectively. The EPA is...

  3. Self-scrubbing coal{sup TM}: An integrated approach to clean air. A proposed Clean Coal Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    This environmental assessment (EA) was prepared by the U.S.Department of Energy (DOE), with compliance with the National Environmental Policy Act (NEPA) of 1969, Council on Environmental Quality (CE) regulations for implementating NEPA (40 CFR 1500-1508) and DOE regulations for compliance with NEPA (10 CFR 1021), to evaluate the potential environmental impacts associated with a proposed demonstration project to be cost-shared by DOE and Custom Coals International (CCI) under the Clean Coal Technology (CCT) Demonstration Program of DOE`s Office of Fossil Energy. CCI is a Pennsylvania general partnership located in Pittsburgh, PA engaged in the commercialization of advanced coal cleaning technologies. The proposed federal action is for DOE to provide, through a cooperative agreement with CCI, cost-shared funding support for the land acquisition, design, construction and demonstration of an advanced coal cleaning technology project, {open_quotes}Self-Scrubbing Coal: An Integrated Approach to Clean Air.{close_quotes} The proposed demonstration project would take place on the site of the presently inactive Laurel Coal Preparation Plant in Shade Township, Somerset County, PA. A newly constructed, advanced design, coal preparation plant would replace the existing facility. The cleaned coal produced from this new facility would be fired in full-scale test burns at coal-fired electric utilities in Indiana, Ohio and PA as part of this project.

  4. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    DEFF Research Database (Denmark)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo

    2011-01-01

    Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some...... air cleaners are largely ineffective, and some produce harmful by-products. To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North...... technologies was able to effectively remove all indoor pollutants and many were found to generate undesirable by-products during operation. (2) Particle filtration and sorption of gaseous pollutants were among the most effective air cleaning technologies, but there is insufficient information regarding long...

  5. OH and HO2 chemistry in clean marine air during SOAPEX-2

    Directory of Open Access Journals (Sweden)

    R. Sommariva

    2004-01-01

    Full Text Available Model-measurement comparisons of HOx in extremely clean air ([NO] The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM. Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 17 NMHCs, while the "simple" model contained only the CO and CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx concentrations predicted by the two models agreed to within 5–10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion technique during four days of clean Southern Ocean marine boundary layer (MBL air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D and [HCHO] and of the kinetic parameters that determine the efficiency of O(1D to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30–40% for OH and 25–30% for HO2 was estimated for the model calculations using a Monte Carlo technique coupled with Latin Hypercube Sampling (LHS.

  6. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    Science.gov (United States)

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  7. Norma Primaria de calidad del aire AIR QUALITY STANDARD

    Directory of Open Access Journals (Sweden)

    PATRICIA MATUS C.

    2002-04-01

    Full Text Available Las normas primarias de calidad del aire tienen por finalidad proteger la salud de la población de la contaminación atmosférica. Ellas establecen un nivel de riesgo socialmente aceptado. Este artículo describe los antecedentes considerados durante el proceso de actualización de la regulación vigente en Chile. Detalla conceptos sobre la calidad del aire, describe los efectos en la salud de los contaminantes, y el procedimiento seguido para fijar los nuevos estándares Finaliza enumerando la norma primaria de calidad del aire, sus valores y los limites definidos para ser considerados en el ámbito de la gestión de los episodios críticos o de alta contaminaciónThe main purpose of air quality standards is to protect people health from air pollution. They establish a socially accepted level of risk. This article describes the background information considered during the process for updating the current Chilean regulation. Concepts about quality of air, and the effects of the pollutants on the health are described. The procedure followed to fix the new standards is detailed. Finally we state the primary air quality norm, its values as well as the critical limits in order to control critical events of high air pollution

  8. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Science.gov (United States)

    2010-07-01

    ..., whichever date comes first, an owner or operator of pneumatic coal-cleaning equipment constructed... date comes first, an owner or operator of pneumatic coal-cleaning equipment constructed, reconstructed... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic...

  9. Radical observations during the Clean air for London project

    Science.gov (United States)

    Whalley, L. K.; Stone, D.; Clancy, N.; Lee, J. D.; Laufs, S.; Kleffmann, J.; Heard, D. E.

    2012-12-01

    With greater than 50 % of the global population residing in urban conurbations, poor urban air quality has a demonstrable effect on human health. OH and HO2 radicals, (collectively termed HOx) together with RO2 radicals, mediate virtually all of the oxidative chemistry in the atmosphere, being responsible for the transformation of primary emissions into secondary pollutants such as NO2, O3 and particulates. Understanding the chemistry of free-radicals in the atmosphere is essential in improving predictions of the lifetimes of pollutants and spatial scales of their transport within urban areas. Results from earlier field campaigns in urban and polluted regions have demonstrated the significance of HONO photolysis and alkene ozonolysis in the production of HOx radicals. In many cases, however, measurements of HONO have not been made, reducing the ability to evaluate model successes for OH in these environments. Here we present measurements of OH, HO2, RO2 and OH reactivity taken during the wintertime (January - February, 2012) and summertime (July - August, 2012) as part of the Clean air for London (ClearfLo) project in London. RO2 was detected using a newly developed flow-reactor laser-induced fluorescence technique which is able to discriminate between HO2 and organic peroxy radicals [1]. Low concentrations of radicals were observed during the wintertime, midday [OH], [HO2] and [RO2] were ~ 0.04, 0.8 and 1.5 pptv respectively, comparable to observations of radicals at other urban locations in winter [2,3,4], and which displayed a negative correlation with NO concentrations. OH reactivity was high and largely tracked the diurnal profiles of NOx and CO, with the highest reactivity ~100 s-1 observed during the morning rush hour. Analysis of factors controlling OH concentrations during the wintertime suggests that the formation of OH from the photolysis of O3 and subsequent reaction of O(1D) with H2O is a minor contribution both under high and low NOx conditions owing

  10. Self-Scrubbing Coal -- an integrated approach to clean air

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, K.E. [Custom Coals Corp., Pittsburgh, PA (United States)

    1997-12-31

    Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceeding boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.

  11. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  12. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a)...

  13. Should You Have the Air Ducts in Your Home Cleaned?

    Science.gov (United States)

    ... home are present, you may wish to consider leaving the premises while the biocide is being applied ... About Indoor Air Quality U.S. Environmental Protection Agency Office of Radiation and Indoor Air Indoor Environments Division ( ...

  14. Give clean air the economic value it deserves

    Energy Technology Data Exchange (ETDEWEB)

    Verhagen, H. [United Air Fund, Amsterdam (Netherlands)

    2000-07-01

    India contributes more to the management of the atmosphere than a country like the Netherlands. This is not to the credit of the Indian government; rather, it is merely a consequence of poverty. Poor people use almost no fossil fuels and emit almost no CO2. Paying developing countries for this environmental service to the world community would create a financial incentive to continue to provide this service in the future, while at the same time generating additional funds to improve the living standards of the poorest people. The attractiveness of this approach depends on one important assumption: the conventional development path - economic growth implies emissions - must be replaced by a sustainable development path delinks economic growth from increasing emissions. Rich industrialised countries also have an interest in such decoupling. The compensation they pay the developing countries would fall proportionately to the reduction of their CO2 emissions. So an incentive is created on both sides to switch over to a low-carbon energy strategy. After the completion of this transition, every country can use as much energy as it wants, because energy consumption would then no longer cause CO2 emissions. This is the picture of the future to which the United Air Fund aspires.

  15. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  17. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA`s Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  18. Airborne lidar mapping of vertical ozone distributions in support of the 1990 Clean Air Act Amendments

    Science.gov (United States)

    Uthe, Edward E.; Nielsen, Norman B.; Livingston, John M.

    1992-01-01

    The 1990 Clean Air Act Amendments mandated attainment of the ozone standard established by the U.S. Environmental Protection Agency. Improved photochemical models validated by experimental data are needed to develop strategies for reducing near surface ozone concentrations downwind of urban and industrial centers. For more than 10 years, lidar has been used on large aircraft to provide unique information on ozone distributions in the atmosphere. However, compact airborne lidar systems are needed for operation on small aircraft of the type typically used on regional air quality investigations to collect data with which to develop and validate air quality models. Data presented in this paper will consist of a comparison between airborne differential absorption lidar (DIAL) and airborne in-situ ozone measurements. Also discussed are future plans to improve the airborne ultraviolet-DIAL for ozone and other gas observations and addition of a Fourier Transform Infrared (FTIR) emission spectrometer to investigate the effects of other gas species on vertical ozone distribution.

  19. OH and HO2 chemistry in clean marine air during SOAPEX-2

    Directory of Open Access Journals (Sweden)

    A. C. Lewis

    2004-01-01

    Full Text Available Model-measurement comparisons of HOx in extremely clean air ([NO]<3  ppt are reported. Measurements were made during the second Southern Ocean Photochemistry Experiment (SOAPEX-2, held in austral summer 1999 at the Cape Grim Baseline Air Pollution Station in north-western Tasmania, Australia. The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM. Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 15 NMHCs, while the "simple" model contained only the CO and  CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx concentrations predicted by the two models agreed to within 5–10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion technique during four days of clean Southern Ocean marine boundary layer (MBL air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D and [HCHO] and of the kinetic parameters that determine the efficiency of  O(1D to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30–40% for OH and

  20. Your Right to Clean Air, A Manual for Citizen Action.

    Science.gov (United States)

    1970

    This manual provides the citizen with basic information for taking action against air pollution. A summary of the effects of various concentrations of sulfur oxides, particulate matter, carbon monoxide, photochemical smog, and hydrocarbons is presented. Suggestions are made for obtaining information about community air pollution problems, and how…

  1. Wet-air oxidation cleans up black wastewater

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    Sterling Organics produces the analgesic paracetamol (acetaminophen) at its Dudley, England, plant. The wastewater from the batch process contains intermediates such as para-aminophenol (PAP) and byproducts such as thiosulfates, sulfites and sulfides. To stay ahead of increasingly strict environmental legislation, Sterling Organics installed a wet-air oxidation system at the Dudley facility in August 1992. The system is made by Zimpro Environmental Inc. (Rothschild, Wis.). Zimpro's wet-air oxidation system finds a way around the limitations of purely chemical or physical processes. In the process, compressed air at elevated temperature and pressure oxidizes the process intermediates and byproducts and removes the color from the wastewater.

  2. Eastern States Harness Clean Energy to Promote Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    2007-10-01

    States on the East Coast are including renewable energy and energy efficiency projects into their air quality plans that they submit to the EPA to address nonattainment for nitrogen oxides and other pollutants.

  3. California Clean Air Act: A compliance strategy for the City of San Diego`s non-emergency fleet

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-31

    Historically, parts of California have had the worst air quality in the nation. The California Energy Commission began experimenting with alternate fuels in the 1970`s in an effort to reduce harmful automobile emissions and hence, improve air quality. It is recognized that the costs to California which result from our air quality problems are immense. Ten to twenty billion dollars each year is the estimated damage in terms of health impacts, materials damages, lost agricultural crop output and forest damages. As the California population increases and health care costs escalate, the total monetary damages from air pollution will increase. The California Energy Commission goal to improve air quality became a mandate in 1988 with the passage of the California Clean Air Act (CCAA). The CCAA requires a revised air quality strategy for the San Diego district since we do not meet State air quality standards for smog, carbon monoxide and nitrogen dioxide. Smog remains San Diego`s major air quality problem, even though the annual number of days each year over the Federal standard has been reduced by 55 percent in the past ten years. Ten years ago about two-thirds of San Diego`s smog was transported from Los Angeles. Today more than 60 per cent of the days San Diego exceeds the State standard are from locally generated smog. It is estimated that 57% of the reactive hydrocarbon emissions (which react with nitrogen dioxide in the presence of sunlight to form smog) is from cars, trucks and buses. The Air Pollution Control District (part of the County of San Diego) is the office that the Air Resources Board has put in charge of creating regulations and designing strategy to reduce polluting emissions. The purpose of this project is to determine the full cost of acquiring and operating a municipal fleet which meets the mandates of the California Clean Air Act. With that information, a plan to meet the Clear Air Act (CCAA) requirements can be formulated by local government.

  4. Can Market Forces Clean The Air In Metro Manila?

    OpenAIRE

    Catherine Frances J. Corpuz

    1999-01-01

    Metro Manila, like many cities in Southeast Asia, is badly affected by poor air quality. Legislation has failed to combat the problem due to inadequate regulatory enforcement and industry's cavalier attitude towards pollution. However a recent economic study has found that a solution to this crisis could be provided by taxation and other similar economic instruments. The study drew on a wide range of research and information to get an overview of the air pollution situation in Metro Manila. T...

  5. 77 FR 53199 - California State Motor Vehicle Pollution Control Standards; Advanced Clean Car Program; Request...

    Science.gov (United States)

    2012-08-31

    ... AGENCY California State Motor Vehicle Pollution Control Standards; Advanced Clean Car Program; Request... control of emissions from new motor vehicles or new motor vehicle engines subject to this part. No state... crankcase emission standards) for the control of emissions from new motor vehicles or new motor vehicle...

  6. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria;

    2013-01-01

    The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...... rate and tear film quality. In a test room with DV and six workstations 30 human subjects were exposed for four hours to each of the following 5 experimental conditions: 23 °C and DV only, 23 °C and DPV with air filter, 29 °C and DV only, 29 °C and DPV, and 29 °C and DPV with air filter. At warm...... environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film...

  7. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Fisk, William J.

    2007-08-01

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  8. Window-mounted unit cleans air at hazardous waste site

    Energy Technology Data Exchange (ETDEWEB)

    Battaglia, J.M. (Independent Equipment Corp., Raritan, NJ (United States)); Sawyer, P.

    1994-07-01

    Uncontrolled hazardous waste sites present the potential for exposure to numerous airborne chemicals--both identified and unidentified. This was the case at an Elizabeth, N.J., remediation project managed by a major environmental contractor. The four-acre site housed three active manufacturing facilities and was bordered by an operation commuter railroad line. About 6,300 drums of assorted organic chemicals, mostly acid chlorides and bromides, awaited sampling and removal. In addition, 120 tanks and vessels required sampling, characterization and removal. Due to site restrictions, support trailers were located relatively close to active work areas. Damaged drums littering the site contained water-reactive, organic acid chlorides and bromides, and released slight emissions during humid or rainy conditions. Shifting winds could (and did) carry trace releases or trace contaminants toward the trailers, potentially exposing unprotected workers. Efforts were begun to alleviate even trace contaminant at levels in the remediation site's temporary office trailers. One potential solution to managing trace contaminants at the site was to use a window-mounted, air conditioner-type unit that would replenish each trailer with filtered air three times an hour, and provide positive pressure in the trailer to compensate for repeated openings and closings of doors. The design uses common, off-the-shelf components to temper the approximately 10 percent makeup air, which provides positive pressure.

  9. Proceedings of the 10th world clean air congress. Impacts and management

    Energy Technology Data Exchange (ETDEWEB)

    Kaemaeri, J.; Tolvanen, M.; Anttila, P.; Salonen, R.O. [eds.

    1995-12-31

    Rapid economical growth and expansion of human population have produced a number of environmental problems with varying geographic dimensions. While local problems remain near the pollution sources, the focus of the scientific community is more and more shifted towards regional, continental and global consequences of air pollutants. The theme of the 10th Clean Air Congress `Growing Challenges from Local to Global` reflects the growing demand from the scientific and professional community working in air pollution prevention and environmental protection - more and more complex mechanisms should be understood on a growing spatial scale. The 10th World Clean Air Congress addresses in its more than 400 presentations, documented in three Volumes of Proceedings, the history, the present and the potential futures of the air pollution problems. This volume includes all papers of paths C `Pollutant Impacts`, D `Pollution Management`, and E `Health Effects`. Path C includes numerous highly relevant papers dealing with climate change and greenhouse gases, as well as with environmental effects of air pollutants mostly on materials and vegetation. The most critical issues on air pollutant management throw light on national and regional abatement strategies and on the applicability of various tools for pollution management. The path on effects on human health includes a session on `Air pollution epidemiology` sponsored by the Economic Commission for Europe and a session on `Health effect control strategies` sponsored by the UN World Health Organization. In these sessions invited speakers describe the current understanding of human responses to air pollution exposure

  10. 77 FR 41930 - Bleed Air Cleaning and Monitoring Equipment and Technology

    Science.gov (United States)

    2012-07-17

    ... an opportunity to participate in #0;the rule making prior to the adoption of the final rules. #0; #0... Equipment and Technology ACTION: Notice; request for information. SUMMARY: The FAA seeks information from industry developers, manufacturers, and the public related to effective air cleaning technology and...

  11. 78 FR 11682 - Notice of Lodging of Proposed Settlement Under the Clean Air Act

    Science.gov (United States)

    2013-02-19

    ... violations of the Risk Management Program requirements of the Clean Air Act and 40 CFR part 68 at three of... reproduction costs. Please mail your request and payment to: Consent Decree Library, U.S. DOJ--ENRD, P.O....

  12. 78 FR 1883 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2013-01-09

    ... alleges that Wisconsin Public Service Corporation (``WPS'') failed to comply with certain requirements of... regulations. The complaint alleges that WPS failed to obtain appropriate permits and failed to install and... resolve past Clean Air Act violations and would require WPS to reduce harmful emissions of sulfur...

  13. Clean Air Act Settlement Improves Chemical Safety at Bloomfield, Conn. Meat Processor

    Science.gov (United States)

    A CT co. that runs an ammonia refrigeration system at its meat processing plant has agreed to pay $65K in civil penalties to resolve claims by the EPA that it violated federal clean air laws as well as the federal right-to-know law in its use of ammonia.

  14. Assessing the Link between Environmental Concerns and Consumers' Decisions to Use Clean-Air Vehicles

    Science.gov (United States)

    Plax, Timothy G.; Kearney, Patricia; Ross, Ted J.; Jolly, J. Christopher

    2008-01-01

    A consulting contract with the California Air Resources Board led to a project examining how California drivers' and fleet managers' perceptions, attitudes, and consumer behavior regarding Clean Vehicle Technologies influenced their own energy choices when it came to purchasing vehicles. The consultants examined archival research, conducted focus…

  15. Key Technology and Experimental Results of the Clean Air Heated Facility for Supersonic Combustion

    Institute of Scientific and Technical Information of China (English)

    ZHONG Zipeng; SONG Wenyan; LE Jialing

    2009-01-01

    The scramjet, which is the propulsion of hypersonic vehicle, has become the focus in many military developed countries. The ground tests play an important role in the research of scramjet. There is defect of test medium contamination (the thermochemical characteristic of the ground test medium is different from that of the flight medium) in existing ground test facilities for scramjet combustor experiment. To solve the problem of test medium contamination, the first clean air heated facility of China for scramjet combustor experiment is designed. The key technology of designing the clean air heated facility is summarized. By using bypass duct, combustor model is protected from high temperature. To reduce the switching time between main duct and bypass duct, solenoid valve and water-cooled system were used. Having centrosymmetric structure, the heat radiating area of the facility and heat loss of the facility are much lower than others. Clean air heated facility is adopted to conduct experiment, which is the first experiment of China in clean air inflow, research on hydrogen-fueled and ethylene-fueled ignition and combustion for scramjet combustor at different equivalence ratio. Successful ignition and sustained combustion of hydrogen has been achieved. Successful ethylene ignition and sustained main stream combustion is achieved with normal fuel injection and taking hydrogen as pilot flame. Experiment result shows that the wall pressure of combustor model rises when the equivalence ratio of hydrogen rises. As the wall pressure of combustor model rises, the pressure disturbance influences the shock train in the upstream.

  16. Citizen suit Clean Air Act enforcement: An update

    Energy Technology Data Exchange (ETDEWEB)

    Wright, W.G. Jr.

    1999-07-01

    Almost every federal environmental statute has a provision that allows citizens to sue violators in lieu of governmental enforcement authorities under certain circumstances. Generally, if the relevant governmental enforcement authority was not deemed to be diligently prosecuting enforcement action against an alleged violator and certain procedural requirements were met a citizens suit could be filed in federal court. If a violation was proved penalties could be assessed against the violator and the plaintiff citizen could receive reimbursement of both his or her attorney's fees and other expenses. Historically, however, the only federal statute that has been the subject of significant citizens suit activity has been the federal Clean Water Act (CWA). This paper will explore a variety of events that are expected to significantly increase the number of citizen suits CAA permitted facilities will face over the next ten years. The paper will briefly address the role the Title V operating permit will play. It will also include a discussion of how this permit will now encompass specific emission limitations along with a mandate to report exceedances. Further, and equally important, will be the role of the 1997 federal Environmental Protection Agency any credible evidence rule which potentially broadens the type, amount, and accessibility available to a CAA citizen suit plaintiff. This rule along with the additional monitoring data that will be generated by the Title V periodic and compliance assurance monitoring requirements will be an issue. Two important CAA citizen suits will be discussed which illustrate the potential role of credible evidence. Also, recent citizen suit decisions involving other federal environmental statutes with implications for the CAA will be examined. Further, the paper will provide some thoughts on how facilities can protect themselves to the extent possible against citizen suits.

  17. 75 FR 68094 - Partial Grant and Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy...

    Science.gov (United States)

    2010-11-04

    ... Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy To Increase the Allowable... AGENCY [EPA-HQ-OAR-2009-0211; FRL-9215-5] Partial Grant and Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy To Increase the Allowable Ethanol Content of Gasoline to 15 Percent...

  18. 23 CFR 633.211 - Implementation of the Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-04-01

    ... Water Pollution Control Act. 633.211 Section 633.211 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT...) implementing requirements with respect to the Clean Air Act and the Federal Water Pollution Control Act are... Contracts (Appalachian Contracts) § 633.211 Implementation of the Clean Air Act and the Federal...

  19. 78 FR 63494 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act and the Emergency Planning...

    Science.gov (United States)

    2013-10-24

    ... of Lodging of Proposed Consent Decree Under the Clean Air Act and the Emergency Planning and Community Right-To Know Act On September 30, 2013, the Department of Justice lodged a proposed Consent... Door Company, Civil Action No. 6:13-cv-01738-MC. In this lawsuit filed under the Clean Air Act and...

  20. Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act_considered MAJOR permits

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act, considered "major" permits. Also includes emission points...

  1. 40 CFR 63.5734 - What standards must I meet for resin and gel coat application equipment cleaning operations?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true What standards must I meet for resin... Pollutants for Boat Manufacturing Standards for Resin and Gel Coat Application Equipment Cleaning Operations § 63.5734 What standards must I meet for resin and gel coat application equipment cleaning...

  2. Measuring the benefits of clean air and water

    Energy Technology Data Exchange (ETDEWEB)

    Kneese, A.V.

    1984-01-01

    Methods are discussed for quantitatively estimating the benefits derived from the maintenance or improvement of air and water quality. Investigations are centered on two broad approaches. The first approach involves methods based, however indirectly, on observed human behavior with respect to environmental good, including travel to recreational opportunities of varying quality and prices paid for houses in different locations. The second approach involves questioning respondents about their willingness to pay for various hypothetical changes in environmental quality. Included in this book is the current state of the art regarding benefits assessment, including such tools as bidding games, surveys, property-value studies, wage differentials, risk-reduction evaluation, and mortality and morbidity cost estimation.

  3. Cleaning mechanism of particle contaminants on large aperture optical components by using air knife sweeping technology

    Science.gov (United States)

    Niu, Longfei; Liu, Hao; Miao, Xinxiang; Lv, Haibing; Yuan, Xiaodong; Zhou, Hai; Yao, Caizhen; Zhou, Guorui; Li, Qin

    2017-05-01

    The cleaning mechanism of optical surface particle contaminants in the light pneumatic tube was simulated based on the static equations and JKR model. Cleaning verification experiment based on air knife sweeping system and on-line monitoring system in high power laser facility was set up in order to verify the simulated results. Results showed that the removal ratio is significantly influenced by sweeping velocity and angle. The removal ratio can reach to 94.3% by using higher input pressure of the air knife, demonstrating that the air knife sweeping technology is useful for maintaining the surface cleanliness of optical elements, and thus guaranteeing the long-term stable running of the high power laser facility.

  4. Bed-integrated local exhaust ventilation system combined with local air cleaning for improved IAQ in hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Mizutani, Chiyomi;

    2016-01-01

    The performance of a ventilated mattress (VM) used as a bed-integrated local exhaust ventilation system combined with air cleaning fabric (acid-treated activated carbon fibre (ACF) fabric) was developed and studied. The separate and combined effect of the VM and the local air cleaning for reducing...... micro-environment was exhausted. Two modes of operation were studied: 1) the exhausted polluted air was discharged out of the room and 2) the polluted air was cleaned by the ACF material installed inside the mattress and recirculated back into the room. Both modes of operation efficiently reduced...

  5. 77 FR 12524 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule...) under the Clean Air Act (CAA). This submittal incorporates the National Ambient Air Quality...

  6. Investigation of efficiency of air cleaning from acetone using a segmental construction biofilter

    Directory of Open Access Journals (Sweden)

    Denas Bacevičius

    2015-10-01

    Full Text Available Volatile organic compounds, e. g. acetone, have a direct impact on climate change, decrease of ozone in the air, and on the growth of greenhouse effect. One of the most popular air purifying methods from VOC is a biological air cleaning. Experimental investigations were conducted to determine the efficiency of the new structure of biofilter with polypropylene plates segments. During the investigations the efficiency of segmental construction biofilter of air purification at different initial concentrations of pollutants was determined. Different concentrations of pollutants were estimated during the acetone dilution with water. During the tests the efficiency of biofilter air purification from acetone vapor and its change under different concentrations of vapors was set. Based on test results, the maximum efficiency of biofilter air purification was up to 93%. Studies have shown that increasing the allowable pollutant concentration, the efficiency of air purification unit decreases. Increasing the concentration of supplied acetone vapor into the biofilter from 232 to 701 mg/m3, cleaning efficiency decreased from 92.8 to 82.3%. Since microorganisms fail to oxidize organic compounds, the filter works better at lower initial concentrations of pollutants.

  7. Fighting ambient air pollution and its impact on health: from human rights to the right to a clean environment.

    Science.gov (United States)

    Guillerm, N; Cesari, G

    2015-08-01

    Clean air is one of the basic requirements of human health and well-being. However, almost nine out of 10 individuals living in urban areas are affected by air pollution. Populations living in Africa, South-East Asia, and in low- and middle-income countries across all regions are the most exposed. Exposure to outdoor air pollution ranks as the ninth leading risk factor for mortality, killing 3.2 million people each year, especially young children, the elderly, persons with lung or cardiovascular disease, those who work or exercise outdoors and low-income populations. In October 2013, the International Agency for Research on Cancer (IARC) classified outdoor air pollution as carcinogenic to humans, calling air pollution 'a major environmental health problem'. Human rights and environmental norms are powerful tools to combat air pollution and its impact on health. The dependence of human rights on environmental quality has been recognised in international texts and by human rights treaty bodies. The growing awareness of the environment has already yielded considerable legislative and regulatory output. However, the implementation of standards remains a pervasive problem. In the fight against violations of norms, citizens have a crucial role to play. We discuss the relevance of a yet to be proclaimed standalone right to a healthy environment.

  8. 40 CFR 52.14 - State ambient air quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false State ambient air quality standards. 52... quality standards. Any ambient air quality standard submitted with a plan which is less stringent than a national standard is not considered part of the plan....

  9. Cost-effectiveness and Economic Incidence of a Clean Energy Standard

    Energy Technology Data Exchange (ETDEWEB)

    Mignone, Bryan K.; Alfstad, Thomas; Bergman, Aaron; Dubin, Kenneth; Duke, Richard; Friley, Paul; Martinez, Andrew; Mowers, Matthew; Palmer, Karen; Paul, Anthony; Showalter, Sharon; Steinberg, Daniel; Woerman, Matt; Wood, Frances

    2012-07-01

    A Clean Energy Standard (CES) is a flexible, market-based policy instrument that could be adopted to reduce greenhouse gas emissions from the U.S. electricity system over time. This paper uses several well-known energy system and electricity models to analyze a CES that reflects broad principles outlined in President Obama's January 2011 State of the Union Address and in the Administration's subsequent Blueprint for a Secure Energy Future. 1 In particular, it examines three different design options for a CES that would each lead to approximately 80% clean electricity by 2035. These different design options provide broadly similar economic incentives for clean energy deployment and yield similar overall welfare impacts, but they exhibit different distributional outcomes. The most inclusive CES crediting approach favors producers over consumers in competitive electricity markets as well as regions with larger initial endowments of clean energy. On the other hand, the most restrictive crediting approach favors consumers over producers and reduces preferences for regions with larger initial endowments of clean energy. While specific technology outcomes vary across the four models used in this study, key insights about cost-effectiveness and economic incidence are largely robust to the underlying modeling platform. These insights may be important considerations in future CES policy design efforts.

  10. A Multilevel Test of Constrained Choices Theory: The Case of Tobacco Clean Air Restrictions.

    Science.gov (United States)

    Vuolo, Mike; Kadowaki, Joy; Kelly, Brian C

    2016-09-01

    According to Bird and Rieker's sociology of constrained choices, decisions and priorities concerning health are shaped by the contexts-including policy, community, and work/family-in which they are formulated. While each level received attention in the original and subsequent research, we contend their constrained choices theory provides a powerful multilevel framework for modeling health outcomes. We apply this framework to tobacco clean air restrictions, combining a comprehensive database of tobacco policies with the National Longitudinal Survey of Youth 1997 from ages 19 to 31. Using multilevel panel models, we find that clean air policies lower the odds of past 30 day smoking and dependence while controlling for other policy-, city-, and individual-level constraints. We also find unique between- and within-person effects, as well as gender effects, for the constraint levied by smoking bans. We argue for the theory's broad applicability beyond commonly cited findings regarding gender and biological influences.

  11. The Impact of the Clean Air Acts on Coal Mining Employment in Kentucky

    OpenAIRE

    Hoag, John H.; Reed, J. David

    2002-01-01

    This article provides empirical evidence that environmental legislation affecting coal mining employment passed in 1977 had different effects on Western Kentucky, where the coal is of higher sulfur content, compared to Eastern Kentucky, where coals are of lower sulfur content, while the 1990 amendments to the Clean Air Act had no statistically significant impact in either region. The 1977 law generated a statistically significant reduction in West Kentucky employment. In addition, it appears ...

  12. Experimental Study on Indoor Air Cleaning Technique of Nano-Titania Catalysis Under Plasma Discharge

    Institute of Scientific and Technical Information of China (English)

    GAO Deli; YANG Xuechang; ZHOU Fei; WU Yuhuang

    2008-01-01

    In this study, a new technique of air cleaning by plasma combined with catalyst was proposed, which consisted of electrostatic precipitation, volatile organic compounds (VOCs) decomposition and sterilization. A novel indoor air purifier based on this technique was adopted. The experimental results showed that formaldehyde decomposition by the plasma-catalyst hybrid system was more efficient than that by plasma only. Positive discharge was better than negative discharge in formaldehyde removal. Meanwhile, the outlet concentration of ozone byproduct was effectively reduced by the nano-titania catalyst.

  13. Standard Test Method for Stress-Corrosion of Titanium Alloys by Aircraft Engine Cleaning Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method establishes a test procedure for determining the propensity of aircraft turbine engine cleaning and maintenance materials for causing stress corrosion cracking of titanium alloy parts. 1.2 The evaluation is conducted on representative titanium alloys by determining the effect of contact with cleaning and maintenance materials on tendency of prestressed titanium alloys to crack when subsequently heated to elevated temperatures. 1.3 Test conditions are based upon manufacturer's maximum recommended operating solution concentration. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see and .

  14. Cleaning Pakistan's Air : Policy Options to Address the Cost of Outdoor Air Pollution

    OpenAIRE

    Sanchez-Triana, Ernesto; Enriquez, Santiago; Afzal, Javaid; Nakagawa,Akiko; Khan, Asif Shuja

    2014-01-01

    Pakistan's urban air pollution is among the most severe in the world and it engenders significant damages to human health and the economy. Air pollution, inadequate water supply, sanitation, and hygiene are the top environmental priority problems in Pakistan. Industrialization and urbanization, in conjunction with motorization, can result in further deterioration of urban air quality. This...

  15. 76 FR 36917 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Science.gov (United States)

    2011-06-23

    ... AGENCY Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for TransAlta Centralia Generation, LLC--Coal- Fired Power Plant AGENCY: Environmental Protection Agency (EPA... to a citizen petition asking EPA to object to an operating permit issued by the Southwest Clean...

  16. Cleaning Products and Air Fresheners: Emissions and ResultingConcentrations of Glycol Ethers and Terpenoids

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.; Nazaroff,William W.

    2005-08-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.

  17. Effects of welding fumes on nuclear air cleaning system carbon adsorber banks

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, P.W. [Duke Power Company, Huntersville, NC (United States)

    1997-08-01

    Standard Technical Specifications for nuclear air cleaning systems include requirements for surveillance tests following fire, painting, or chemical release in areas communicating with the affected system. To conservatively implement this requirement, many plants categorize welding as a chemical release process, and institute controls to ensure that welding fumes do not interact with carbon adsorbers in a filter system. After reviewing research data that indicated welding had a minimal impact on adsorber iodine removal efficiency, further testing was performed with the goal of establishing a welding threshold. It was anticipated that some quantity of weld electrodes could be determined that had a corresponding detrimental impact on iodine removal efficiency for the exposed adsorber. This value could be used to determine a conservative sampling schedule that would allow the station to perform laboratory testing to ensure system degradation did not occur without a full battery of surveillance tests. A series of tests was designed to demonstrate carbon efficiency versus cumulative welding fume exposure. Three series of tests were performed, one for each of three different types of commonly used weld electrodes. Carbon sampling was performed at baseline conditions, and every five pounds of electrode thereafter. Two different laboratory tests were performed for each sample; one in accordance with ASTM 3803/1989 at 95% relative humidity and 30 degrees C, and another using the less rigorous conditions of 70% relative humidity and 80 degrees C. Review of the test data for all three types of electrodes failed to show a significant correlation between carbon efficiency degradation and welding fume exposure. Accordingly, welding is no longer categorized as a `chemical release process` at McGuire Nuclear Station, and limits on welding fume interaction with ventilation systems have been eliminated. 4 refs., 3 figs., 1 tab.

  18. 75 FR 71033 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2010-11-22

    ... AGENCY 40 CFR Part 81 RIN-2060-AP78 Air Quality Designations for the 2008 Lead (Pb) National Ambient Air... establishes air quality designations for certain areas in the United States for the 2008 lead (Pb) National Ambient Air Quality Standards (NAAQS). Based on air quality monitoring data, EPA is issuing this rule to...

  19. Removal of mercury vapor from ambient air of dental clinics using an air cleaning system based on silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Chiman Saeidi

    2015-06-01

    Full Text Available Background & objective: Mercury is a toxic and bio-accumulative pollutant that has adverse effects on environmental and human health. There have been a number of attempts to regulate mercury emissions tothe atmosphere. Silver nanoparticles are a number of materials that have highly potential to absorb mercury and formation of mercury amalgam.The aim of this study is removal of mercury vapors in the dental clinic using a n a ir cleaning system based on silver nanoparticles. Methods: In this study, silver nanoparticles coated on the bed of foam and chemical and structural properties were determined using a number of methods such as UV-VIS-NIR spectroscopy and Scanning Electron Microscope (SEM connected the X-ray Emission Spectroscopy Energy (EDS. The a ir cleaning system efficiency to remove of the mercury vapor in simulated conditions in the laboratory and real conditions in the dental clinicwere measured by Cold Vapor Atomic Absorption Spectroscopy (CVAAS. Results: The images of SEM, showed that average sizeof silver nanoparticles in colloidal solution was ∼ 30nm and distribution of silver nanoparticles coated on foam was good. EDS spectrum confirmed associated the presence of silver nanoparticles coated on foam. The significantly difference observed between the concentration of mercury vapor in the off state (9.43 ± 0.342 μg.m-3 and on state (0.51 ± 0.031μg.m-3 of the a ir cleaning system. The mercury vapor removal efficiencyof the a ir cleaning system was calculated 95%. Conclusion : The air cleaning system based on foam coated by silver nanoparticles, undertaken to provide the advantages such as use facilitating, highly efficient operational capacity and cost effective, have highly sufficiency to remove mercury vapor from dental clinics.

  20. Accuracy of Linear Depolarisation Ratios in Clean Air Ranges Measured with POLIS-6 at 355 and 532 NM

    Directory of Open Access Journals (Sweden)

    Freudenthaler Volker

    2016-01-01

    Full Text Available Linear depolarization ratios in clean air ranges were measured with POLIS-6 at 355 and 532 nm. The mean deviation from the theoretical values, including the rotational Raman lines within the filter bandwidths, amounts to 0.0005 at 355 nm and to 0.0012 at 532 nm. The mean uncertainty of the measured linear depolarization ratio of clean air is about 0.0005 at 355 nm and about 0.0006 at 532 nm.

  1. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys

    2013-01-01

    ) and six workstations, three of which had DPV. The DV kept air temperature in the occupied zone (1.1 m above the floor). Pollution load was simulated by PVC floor covering and the bioeffluents generated by the subjects (60% recirculated room air). DPV sucked the air distributed over the floor by the DV...... and supplied it to the breathing zone of the subjects. The subjects were allowed to control the position of the DPV supply diffuser and the personalized flow rate. Each subject participated in five 4-hour experiments: 23 °C with DV only, 23 °C with DPV with air filter, 29 °C with DV only, 29 °C with DPV......The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV...

  2. New clean air efforts face tough challenges, say senators and former EPA administrators

    Science.gov (United States)

    Showstack, Randy

    2012-02-01

    With the U.S. Environmental Protection Agency (EPA) coming under repeated attack from some members of Congress and others for perceived heavy-handed regulatory actions, two moderate U.S. senators and two former EPA administrators recently noted the need for continued measures to improve air quality. However, they also acknowledged the difficulty in moving forward with new legislative efforts to revise the federal Clean Air Act to further reduce air pollution in the current polarized political climate. "Nobody who wants to see constructive changes [to the act] would dare touch it or propose it in the current climate," said former EPA administrator William Reilly at a 23 January forum sponsored by the World Resources Institute. Reilly, who served as EPA administrator from 1989 to 1992, noted that bipartisan congressional support had been key to addressing many environmental problems up until the mid-1990s.

  3. Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone

    DEFF Research Database (Denmark)

    Singer, B.C.; Coleman, B.K.; Destaillats, H.

    2006-01-01

    This study investigated the formation of secondary pollutants resulting from household product use in the presence of ozone. Experiments were conducted in a 50-m(3) chamber simulating a residential room. The chamber was operated at conditions relevant to US residences in polluted areas during warm......-oil air freshener (AFR) was operated for several days. Cleaning products were applied realistically with quantities scaled to simulate residential use rates. Concentrations of organic gases and secondary organic aerosol from the terpene-containing consumer products were measured with and without ozone...... than 100 mu g m(-3)) in some experiments. Ozone consumption and elevated hydroxyl radical concentrations persisted for 10-12 h following brief cleaning events, indicating that secondary pollutant production can persist for extended periods. (c) 2006 Elsevier Ltd. All rights reserved....

  4. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    and is determined mainly considering the metabolic CO2 production. It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source control and when air used for ventilation is clean health-based ventilation rate should......Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main factors that affect negatively the characteristics of the air they breathe are outdoor air used to ventilate indoor spaces and indoor...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...

  5. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and...

  6. Air quality standards and town planning; Luchtkwaliteitsbeleid in ruimtelijk perspectief

    Energy Technology Data Exchange (ETDEWEB)

    Van Dam, C.E.; Kruyt, H.A.; Dorel, F.G. [Bureau Luchtkwaliteit en Veiligheid, Directie Water en Milieu, Provincie Zuid-Holland, The Hague (Netherlands)

    1998-08-01

    Current levels of air pollutants still cause effects on human health. Therefore it is necessary to pay attention to air quality during town planning processes. A study of the Dutch Province of South Holland showed exceedances of air quality standards near motorways in 1995 as well as in 2010. Some objects should be excluded from these zones. These are objects where people either stay during a long time of the day, or are sensitive for air pollutants or places for physical exercising. Examples of these are houses, schools and hospitals. A scheme is presented for local authorities to take Dutch Air Quality Standards into account during physical planning. 7 refs.

  7. 77 FR 30087 - Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards

    Science.gov (United States)

    2012-05-21

    ... 21, 2012 Part III Environmental Protection Agency 40 CFR Parts 50, 51 and 81 Air Quality Designations for the 2008 Ozone National Ambient Air Quality Standards; Implementation of the 2008 National Ambient Air Quality Standards for Ozone: Nonattainment Area Classifications Approach, Attainment Deadlines and...

  8. Development of a Standardized Procedure for Cleaning Glass Apparatus in Analytical Laboratories

    Directory of Open Access Journals (Sweden)

    HUDSON C. POLONINI

    2011-06-01

    Full Text Available ABSTRACT Adequate cleaning of analytical glassware is an essential procedure that determines the reliability of assays and tests carried out in laboratories, keeping the glassware free of interference from residues left by previous tests. In the present paper, standard cleaning procedures are proposed for laboratory glassware, which were tested on cyanocobalamin as a marker contaminant. A spectrophotometric method was used for quantitative determination of both residual marker and cleaning product. Beakers, volumetric flasks and volumetric pipettes were successfully cleaned with a 2% detergent solution, with several rinses in water. Vials were cleaned adequately in an ultrasonic bath. These procedures utilize non-toxic and cheap reagents, factors of paramount importance for their application in routine laboratory analysis. Keywords: Validation Studies. Detergents. Laboratory Techniques and Procedures. Glassware Cleaning. RESUMO Desenvolvimento de procedimento padronizado para a lavagem de vidraria em laboratórios analíticos A lavagem da vidraria analítica é um procedimento essencial e determinante na confiabilidade dos resultados de testes e ensaios, a despeito da interferência dos resíduos de análises anteriores. Neste trabalho, foram propostos procedimentos de limpeza de vidrarias utilizando cianocobalamina como um marcador da eficiência de limpeza. Foi utilizado método espectrofotométrico para determinação dos resíduos do marcador e também do agente de limpeza. Béqueres, balões volumétricos e pipetas volumétricas foram comprovadamente limpos com detergente a 2% e múltiplos enxágues. Vials e seringas foram apropriadamente limpos utilizando-se banho ultrassônico. Esses procedimentos de limpeza fazem uso de reagentes baratos e não tóxicos, parâmetros de suma importância para sua aplicação em rotina laboratorial de análises físico-químicas. Palavras-chave: Estudos de Validação. Detergentes. Técnicas e

  9. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  10. 76 FR 72097 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-11-22

    ... AGENCY 40 CFR Part 81 RIN 2060-AR17 Air Quality Designations for the 2008 Lead (Pb) National Ambient Air... establishes air quality designations for most areas in the United States for the 2008 lead (Pb) National Ambient Air Quality Standards (NAAQS). In a previous action established on November 16, 2010, the EPA...

  11. The North Carolina Department of Environment and Natural Resources: clean land, water, and air for healthy people and communities.

    Science.gov (United States)

    Riegel, Lisa Diaz; Wakild, Charles; Boothe, Laura; Hildebrandt, Heather J; Nicholson, Bruce

    2012-01-01

    The North Carolina Department of Environment and Natural Resources works with communities and other agencies to sustain clean air, water, and land. Sustainability efforts include protecting air quality through community design, community enhancement through brownfields revitalization, community development strategies to protect water resources, and the integration of natural resource conservation.

  12. 中央空调管道清洗机器人控制系统设计%Design of central air conditioning duct cleaning robot control system

    Institute of Scientific and Technical Information of China (English)

    何琴

    2011-01-01

    In order to solve the problems of central air conditioning duct diameter non-standard and the difficulty of the duct cleaning,the automatic centering technology was investigated. After analysing the central air conditioning duct cleaning robot control system,adopting a modular design thought, taking ATmega64 microcontroller as the control core,the relations between modules were established. A method was presented to the central air conditioning duct cleaning robot control system design. The cleaning technology was evaluated based on the existing cleaning technology. The results show that the cleaning robot can achieve automatic centering to adapt different pipe diameters to finish cleaning tasks, provide a broad application prospects for central air conditioning duct cleaning technology.%为解决中央空调管道清洗难及管径不规范等问题,将自动定心技术应用到管道清洗机器人中,开展了中央空调管道清洗机器人控制系统方案分析与设计.采用模块化的设计思想,以ATmega64单片机为控制核心,建立了各个功能模块之间的关系,实现了中央空调管道清洗机器人整个控制系统的方案设计.在现有的中央空调管道清洗技术基础上,对相关研究成果进行了对比分析及评价.研究结果表明,所设计的清洗机器人能够实现自动定心以适应不同的空调管径,完成清洗作业,为中央空调管道清洗技术提供了广阔的应用前景.

  13. National Emission Standards for Hazardous Air Pollutants Calendar Year 2005

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada

    2006-06-01

    The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). From 1951 through 1992, the NTS was operated as the nation’s site for nuclear weapons testing. The release of man-made radionuclides from the NTS as a result of testing activities has been monitored since the first decade of atmospheric testing. After 1962, when nuclear tests were conducted only underground, the radiation exposure to the public surrounding the NTS was greatly reduced. After the 1992 moratorium on nuclear testing, radiation monitoring on the NTS focused on detecting airborne radionuclides that are resuspended into the air (e.g., by winds, dust-devils) along with historically-contaminated soils on the NTS. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (40 Code of Federal Regulations 61 Subpart H) limits the release of radioactivity from a U. S. Department of Energy (DOE) facility (e.g., the NTS) to 10 millirem per year (mrem/yr) effective dose equivalent (EDE) to any member of the public. This is the dose limit established for someone living off of the NTS for inhaling radioactive particles that may be carried by wind off of the NTS. This limit assumes that members of the public surrounding the NTS may also inhale “background levels” or radioactive particles unrelated to NTS activities that come from naturally-occurring elements in the environment (e.g., radon gas from the earth or natural building materials) or from other man-made sources (e.g., cigarette smoke). The U. S. Environmental Protection Agency (EPA) requires DOE facilities (e.g., the NTS) to demonstrate compliance with the NESHAP dose limit by annually estimating the dose to a hypothetical member of the public, referred to as the maximally exposed individual (MEI), or the member of the public who resides within an 80-kilometer (50-mile

  14. Design of wind turbines for non-standard air density

    DEFF Research Database (Denmark)

    Soraperra, Giusepe

    2005-01-01

    New site typologies characterized by non-standard air density have been recently considered for wind energy exploitation. The work attempts to assess the effect of air density on turbine performance, whether with variable or fixed speed. Since the power density of the sites with non......-standard density is intrinsically different, it is impossible to reach the standard rated power at the standard rated speed. Three scenarios are possible (i) to keep the standard rated speed of the turbine by changing the size of the electric generator; (ii) to change the rated speed of the turbine by adopting...... a different pitch angel setting; (iii) adoption of extendeders to the blades can also help in restraining the standard rated power at the standard rated speed for p less than pst. The power curves for the three turbine configurations, each in three different air density conformations, have been calculated...

  15. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor

    2014-01-01

    was evaluated as deodorant materials neutralising ammonia in air. The deodorant material efficiency was tested in a special experimental set-up consisting of a straight pipe section, an ammonia gas generator, a fan and a textile frame. The deodorant materials, placed in the pipe, were exposed to a flow of air...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity....... The porous activated carbon fiber fabric did not have a deodorant effect....

  16. How can the Clean Development Mechanism contribute to better air quality?

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, S.J.A. [ECN Policy Studies, Petten (Netherlands)

    2009-06-15

    Air pollutants and greenhouse gases are to a large extent emitted by the same sources, notably in the industry, transport and residential sectors. However, climate change mitigation is a global issue and is mostly driven by national and international policy. Local governments are in general more interested in improving urban air quality, which is posing serious health hazards across the globe. The Clean Development Mechanism (CDM) was designed to reduce greenhouse gas emissions, helping industrialised countries to achieve their targets under the Kyoto Protocol while contributing to sustainable development in developing countries. As of January 2009 over 4000 projects are in the pipeline. The CDM could be used by local governments and the private sector to finance projects that contribute to both climate change mitigation and better air quality. However, CDM projects in particularly the transport sector face a number of barriers. We identify the most important issues for such projects, as well as the lessons learnt and some recommendations based on four case studies in Asian cities related to biofuels and bus rapid transit systems. The main conclusions is that successful implementation of CDM projects beneficial for urban air quality depends on the applicability of approved CDM methodologies, the strong cooperation between project developers and local authorities, and the availability of data.

  17. Evaluation Clean Air Effects on Tehran City Residential Houses Price in 2009

    Directory of Open Access Journals (Sweden)

    Aghapour Sabbagi M.

    2011-06-01

    Full Text Available BackgroundsandObjectives: Environmental activitiesunknownprice and value caused establishing of some unique characteristics for mentioned commodities. One of these characteristics was existing gap between private and social cost and benefit. For assessing these activities different approaches include travel cost, willingness to pay and hedonic price had been suggested. According to Tehran's air pollution problem, in this study Hedonic approach had was used for the assessment of healthy air on Tehran's residential house price.Materials and Method : Hedonic approach is one of the methods that are used for evolution environmental goods. In this method, each good's price is estimated as a functions of that good`s properties. To gather this study information 300 questionnaires has been collected by random sampling from different area of Tehran.Result: Results revealed that activities in order to reduce air pollutions, in addition to environmental value have economical value form the point of view of consumers. Also, results show that willingness to pay of every Tehran's citizens for every square meter of house located in region with less pollution is between 1120 to 1350 thousands Rials.Conclusion: According to the obtained results can be said that, clean air as an environmental good from the viewpoint of consumers has economic value that can be calculated this value using methods such as Hedonic.

  18. Evaluating the Impact of Air Pollution on Human Health in China: the Price of Clean Air

    Science.gov (United States)

    Wang, X.; Mauzerall, D. L.; Hu, Y.; Russell, A. G.; Woo, J.; Streets, D. G.

    2003-12-01

    Population growth, rapid urbanization and economic development are contributing to increased energy consumption in China. One of the unintended consequences is poor air quality due to a lack of environmental controls. The coal dependent energy structure in China only worsens the situation. Quantification of the environmental costs resulting from air pollution is needed in order to provide a mechanism for making strategic energy policy that accounts for the life-cycle cost of energy use. However, few such studies have been conducted for China that examine the entire energy system. Here we examine the extent to which public health has been compromised due to elevated air pollution and how China could incorporate environmental costs into future energy and environmental policies. Taking the Shandong region in eastern China as a case study, we develop a high-resolution regional inventory for anthropogenic emissions of NOx, CO, PM2.5, PM10, VOCs, NH3 and SO2. SMOKE (Sparse Matrix Operator Kernel Emissions Modeling System) is used to process spatial and temporal distributions and chemical speciation of the regional emissions, MM5 (the Fifth-Generation NCAR/Penn State Meso-scale Model, Version 3) is used to generate meteorology and Models3/CMAQ (Community Multi-scale Air Quality Modeling System) is used to simulate ambient concentrations of particulates and other gaseous species in this region. We then estimate the mortality and morbidity in this region resulting from exposure to these air pollutants. We also estimate the monetary values associated with the resulting mortality and morbidity and quantify the contributions from various economic sectors (i.e. power generation, transportation, industry, residential and others). Finally, we examine the potential health benefits that adoption of best available or advanced energy (coal-based, in particular) and environmental technologies in different sectors could bring about. The results of these analyses are intended to provide

  19. Development of an air cleaning system for dissolving high explosives from nuclear warheads

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Wilson, K.; Staggs, K.; Wapman, D. [Lawrence Livermore National Lab., CA (United States)

    1997-08-01

    The Department of Energy (DOE) has a major effort underway in dismantling nuclear weapons. In support of this effort we have been developing a workstation for removing the high explosive (HE) from nuclear warheads using hot sprays of dimethyl sulfoxide (DMSO) solvent to dissolve the HE. An important component of the workstation is the air cleaning system that is used to contain DMSO aerosols and vapor and radioactive aerosols. The air cleaning system consists of a condenser to liquefy the hot DMSO vapor, a demister pad to remove most of the DMSO aerosols, a high efficiency particulate air (HEPA) filter to remove the remaining aerosols, an activated carbon filter to remove the DMSO vapor, and a final HEPA filter to meet the redundancy requirement for HEPA filters in radioactive applications. The demister pad is a 4{double_prime} thick mat of glass and steel fibers and was selected after conducting screening tests on promising candidates. We also conducted screening tests on various activated carbons and found that all had a similar performance. The carbon breakthrough curves were fitted to a modified Wheeler`s equation and gave excellent predictions for the effect of different flow rates. After all of the components were assembled, we ran a series of performance tests on the components and system to determine the particle capture efficiency as a function of size for dioctyl sebacate (DOS) and DMSO aerosols using laser particle counters and filter samples. The pad had an efficiency greater than 990% for 0.1 {mu}m DMSO particles. Test results on the prototype carbon filter showed only 70% efficiency, instead of the 99.9% in small scale laboratory tests. Thus further work will be required to develop the prototype carbon filter. 7 refs., 18 figs., 10 tabs.

  20. Aqua AIRS Level 3 8-day Standard Physical Retrieval (AIRS-only) V006

    Data.gov (United States)

    National Aeronautics and Space Administration — The AIRS Only Level 3 8-Day Gridded Retrieval Product contains standard retrieval means, standard deviations and input counts. Each file covers an 8-day period, or...

  1. Clean air matters: an overview of traffic-related air pollution and pregnancy

    Science.gov (United States)

    Slovic, Anne Dorothée; Diniz, Carmen Simone; Ribeiro, Helena

    2017-01-01

    ABSTRACT The right to a healthy pregnancy and to giving birth in a safe environment is source of comprehensive research. Decent birth facilities, respect, and no discrimination are already recognized as fundamental rights, but an accurate look at the outdoor environment is required. Air pollution is a dangerous factor to pregnant women and newborns, many of whom highly exposed to traffic-related atmospheric pollutants in urban areas. Such exposure can lead to low birth weight and long-lasting effects, such as respiratory diseases and premature death. Thus, this commentary, based on the analysis of literature, presents the importance of the exposome concept and of epigenetics in identifying the role of the environment for better health conditions of pregnant women and newborns. In the final considerations, this study proposes the deepening of the subject and the mobilization in this regard, with a human rights-based approach to environmental health and to the increased awareness of pregnant women on the risks of air pollution and its effects on health. PMID:28225911

  2. Air Quality of Beijing and Impacts of the New Ambient Air Quality Standard

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2015-08-01

    Full Text Available Beijing has been publishing daily reports on its air quality since 2000, and while the air pollution index (API shows that the air quality has improved greatly since 2000, this is not the perception of Beijing’s residents. The new national ambient air quality standard (NAAQS-2012, which includes the monitoring of PM2.5, has posed stricter standards for evaluating air quality. With the new national standard, the air quality in Beijing is calculated using both NAAQS-2012 and the previous standard. The annual attainment rate has dropped from 75.5% to 50.7%. The spatial analysis of air quality shows that only a background station could attain the national standard, while urban and suburban stations exceed the national standard. Among the six pollutants included in the NAAQS-2012, PM2.5 is the major contributor to the air quality index (AQI comparing with the five other pollutants. The results indicate that under previous NAAQS without PM2.5 monitoring, the air quality has improved greatly in the past decade.  By considering PM2.5, the air quality attainment has dropped greatly. Furthermore, a great effort is needed for local government to bring down the PM2.5 concentration.

  3. 75 FR 15655 - Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

    Science.gov (United States)

    2010-03-30

    ... AGENCY 40 CFR Part 63 RIN 2060-AP91 Requirements for Control Technology Determinations for Major Sources... Division, Office of Air Quality Planning and Standards (D205- 02), Environmental Protection Agency... facilities. Brick and Structural Clay Products; Clay 327122 Ceramic wall and floor tile manufacturing...

  4. Sophisticated Clean Air Strategies Required to Mitigate Against Particulate Organic Pollution

    Science.gov (United States)

    Grigas, T.; Ovadnevaite, J.; Ceburnis, D.; Moran, E.; McGovern, F. M.; Jennings, S. G.; O’Dowd, C.

    2017-01-01

    Since the 1980’s, measures mitigating the impact of transboundary air pollution have been implemented successfully as evidenced in the 1980–2014 record of atmospheric sulphur pollution over the NE-Atlantic, a key region for monitoring background northern-hemisphere pollution levels. The record reveals a 72–79% reduction in annual-average airborne sulphur pollution (SO4 and SO2, respectively) over the 35-year period. The NE-Atlantic, as observed from the Mace Head research station on the Irish coast, can be considered clean for 64% of the time during which sulphate dominates PM1 levels, contributing 42% of the mass, and for the remainder of the time, under polluted conditions, a carbonaceous (organic matter and Black Carbon) aerosol prevails, contributing 60% to 90% of the PM1 mass and exhibiting a trend whereby its contribution increases with increasing pollution levels. The carbonaceous aerosol is known to be diverse in source and nature and requires sophisticated air pollution policies underpinned by sophisticated characterisation and source apportionment capabilities to inform selective emissions-reduction strategies. Inauspiciously, however, this carbonaceous concoction is not measured in regulatory Air Quality networks. PMID:28303958

  5. [Potential exposure to silver nanoparticles during spraying preparation for air-conditioning cleaning].

    Science.gov (United States)

    Jankowska, Elzbieta; Łukaszewska, Joanna

    2013-01-01

    Unique properties of engineered nanomaterials (ENMs) and products made of them have contributed to a rapid progress in the production and application of ENMs in different branches of industry and in factories with different production scale. Bearing in mind that nano-objects (nanoplates, nanofibres, nanoparticles), emitted during ENM production and application, can cause many diseases, even those not yet recognized, extensive studies have been carried all over the world to assess the extent of exposure to nano-objects at workstations and related health effects in workers employed in ENM manufacture and application processes. The study of potential exposure to silver nanoparticles contained in the preparation for air-conditioning cleaning (Nano Silver from Amtra Sp. z o.o.) involved the determination of concentrations and size distribution of particles, using different devices, allowing for tracing changes in a wide range of dimensions, from nano-size (10 nm) to micrometer-size (10 pm), of the particles which are usually inhaled by humans. The results of the study shows that even during a short-term spraying of Nano Silver preparation (for 10 s) at the distance of 52 cm from the place of preparation spraying--particles of 10 nm-10 microm can be emitted into in the air. During a three-fold preparation spraying in similar conditions differences in concentration increase were observed, but in each case the particles remained in the air for a relatively long time.

  6. Sophisticated Clean Air Strategies Required to Mitigate Against Particulate Organic Pollution

    Science.gov (United States)

    Grigas, T.; Ovadnevaite, J.; Ceburnis, D.; Moran, E.; McGovern, F. M.; Jennings, S. G.; O’Dowd, C.

    2017-03-01

    Since the 1980’s, measures mitigating the impact of transboundary air pollution have been implemented successfully as evidenced in the 1980–2014 record of atmospheric sulphur pollution over the NE-Atlantic, a key region for monitoring background northern-hemisphere pollution levels. The record reveals a 72–79% reduction in annual-average airborne sulphur pollution (SO4 and SO2, respectively) over the 35-year period. The NE-Atlantic, as observed from the Mace Head research station on the Irish coast, can be considered clean for 64% of the time during which sulphate dominates PM1 levels, contributing 42% of the mass, and for the remainder of the time, under polluted conditions, a carbonaceous (organic matter and Black Carbon) aerosol prevails, contributing 60% to 90% of the PM1 mass and exhibiting a trend whereby its contribution increases with increasing pollution levels. The carbonaceous aerosol is known to be diverse in source and nature and requires sophisticated air pollution policies underpinned by sophisticated characterisation and source apportionment capabilities to inform selective emissions-reduction strategies. Inauspiciously, however, this carbonaceous concoction is not measured in regulatory Air Quality networks.

  7. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible...

  8. Preservation of atomically clean silicon surfaces in air by contact bonding

    DEFF Research Database (Denmark)

    Grey, Francois; Ljungberg, Karin

    1997-01-01

    When two hydrogen-passivated silicon surfaces are placed in contact under cleanroom conditions, a weak bond is formed. Cleaving this bond under ultrahigh vacuum (UHV) conditions, and observing the surfaces with low energy electron diffraction and scanning tunneling microscopy, we find that the or......When two hydrogen-passivated silicon surfaces are placed in contact under cleanroom conditions, a weak bond is formed. Cleaving this bond under ultrahigh vacuum (UHV) conditions, and observing the surfaces with low energy electron diffraction and scanning tunneling microscopy, we find...... that the ordered atomic structure of the surfaces is protected from oxidation, even after the bonded samples have been in air for weeks. Further, we show that silicon surfaces that have been cleaned and hydrogen-passivated in UHV can be contacted in UHV in a similarly hermetic fashion, protecting the surface...

  9. Development of an emergency air-cleaning system for liquid-metal reactors

    Energy Technology Data Exchange (ETDEWEB)

    Owen, R.K.

    1980-11-01

    A novel air cleaning concept has been developed for potential use in venting future commercial liquid metal fast breeder reactor containment buildings in the unlikely event of postulated core disruptive accidents. The passive concept consists of a submerged gravel bed to collect the bulk of particulate contaminates carried by the vented gas. A fibrous scrubber could be combined with the submerged gravel scrubber to enhance collection efficiencies for the smaller sized particles. The submerged gravel scrubber is unique in that water flow through the packed bed is induced by the gas flow, eliminating the need for an active liquid pump. In addition, design gas velocities through the packed bed are 10 to 20 times higher than for a conventional sand bed filter.

  10. CTEPP STANDARD OPERATING PROCEDURE FOR PRE-CLEANING FILTERS AND XAD-2 (SOP-5.10)

    Science.gov (United States)

    This SOP summarizes the method for pre-cleaning XAD-2 resin and quartz fiber filters. The procedure provides a cleaning method to help reduce potential background contamination in the resin and filters.

  11. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    Energy Technology Data Exchange (ETDEWEB)

    Wright, S.R.; Crouch, H.S.; Bond, J.H. [Micro Composite Materials Corp., Durham, NC (United States)

    1997-08-01

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ {mu}m diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 {mu}m were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs.

  12. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  13. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Science.gov (United States)

    2010-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the...

  14. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Science.gov (United States)

    2010-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  15. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9...

  16. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of...

  17. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    Science.gov (United States)

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

  18. Asbestos: Rationale Behind a Proposed Air Quality Standard

    Science.gov (United States)

    Bruckman, Leonard; Rubino, Robert A.

    1975-01-01

    This article proposes an asbestos air quality standard for Connecticut lower than proposed Federal regulation. Data are given relating mesothelioma incidence to occupational and non-occupational asbestos exposure. New standards lower asbestos emissions from manufacturing operations thus reducing possible asbestos-related fatalities. Rebuttals and…

  19. State Skill Standards: Heating, Ventilation, Air Conditioning, and Refrigeration

    Science.gov (United States)

    Ball, Larry; Soukup, Dennis

    2006-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide career and technical education skill standards. The standards in this document are for Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) programs and are designed to clearly state what the student should know and be able to do upon completion of…

  20. An Air Quality Data Analysis System for Interrelating Effects, Standards and Needed Source Reductions

    Science.gov (United States)

    Larsen, Ralph I.

    1973-01-01

    Makes recommendations for a single air quality data system (using average time) for interrelating air pollution effects, air quality standards, air quality monitoring, diffusion calculations, source-reduction calculations, and emission standards. (JR)

  1. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  2. 78 FR 34177 - Implementation of the 2008 National Ambient Air Quality Standards for Ozone: State Implementation...

    Science.gov (United States)

    2013-06-06

    ... the 2008 National Ambient Air Quality Standards for Ozone: State Implementation Plan Requirements... Ambient Air Quality Standards for Ozone: State Implementation Plan Requirements AGENCY: Environmental... 2008 ozone national ambient air quality standards (NAAQS) (the ``2008 ozone NAAQS'') that...

  3. Exemptions for hookah bars in clean indoor air legislation: a public health concern.

    Science.gov (United States)

    Noonan, Devon

    2010-01-01

    Popularity of waterpipe smoking or hookah smoking in the United States has been growing for some time now among youth and young adults. Currently, many cities and states have exemptions that allow hookah bars to remain in operation despite the passage of clean indoor air legislation. From a public health perspective this is concerning for many reasons. One public health concern with the increase in popularity of this type of tobacco use is the associated health effects. Another concern is that hookah smoke produces a sweet smelling aroma making it less obvious that patrons and employees of hookah bars are inhaling noxious fumes from mainstream smoke, as well as the toxins from the charcoal that is used to heat the tobacco. The purpose of this paper is to discuss smoke-free air legislation in relation to hookah use, the public health implications of exempting hookah bars from current smoke-free legislation, and implications for the public health nurse in protecting the public from the dangers of second-hand smoke, and limiting this new form of tobacco use.

  4. 76 FR 53452 - Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit...

    Science.gov (United States)

    2011-08-26

    ... the U.S. Court of Appeals for Third Circuit. Under the terms of a settlement agreement between EPA and... Circuit Court of Appeals is the appropriate court of appeals. Section 307(b)(1) also requires that any.... Judicial Review Section 307(b)(1) of the Clean Air Act indicates which Federal Courts of Appeals have...

  5. 75 FR 75463 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper...

    Science.gov (United States)

    2010-12-03

    ... From the Federal Register Online via the Government Publishing Office ENVIROMENTAL PROTECTION AGENCY Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper... issues during the comment period or that the grounds for objection or other issue arose after the comment...

  6. 76 FR 11280 - Notice of Lodging of an Amendment to Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-03-01

    ... February 14, 2011, a proposed Amendment to the consent decree in United States et al. v. Lafarge North... states or state agencies against Lafarge North America, Inc.'s, Lafarge Midwest, Inc.'s, and Lafarge Building Materials, Inc.'s (``Lafarge's'') for alleged violations of the Clean Air Act (``CAA'' or...

  7. 77 FR 38830 - Notice of Lodging of an Amendment to Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2012-06-29

    ... June 25, 2012, a proposed Second Amendment to the consent decree in United States et al. v. Lafarge... and twelve states or state agencies against Lafarge North America, Inc., Lafarge Midwest, Inc., and Lafarge Building Materials, Inc. (``Lafarge'') for alleged violations of the Clean Air Act (``CAA''...

  8. 40 CFR 62.15395 - Does this subpart require me to obtain an operating permit under title V of the Clean Air Act?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Does this subpart require me to obtain an operating permit under title V of the Clean Air Act? 62.15395 Section 62.15395 Protection of... require me to obtain an operating permit under title V of the Clean Air Act? Yes. If you are subject...

  9. Plants + microbes: Innovative food crop systems that also clean air and water

    Science.gov (United States)

    Nelson, Mark; Wolverton, B. C.

    The limitations that will govern bioregenerative life support applications in space, especially volume and weight, make multi-purpose systems advantageous. This paper outlines two systems which utilize plants and associated microbial communities of root or growth medium to both produce food crops and clean air and water. Underlying these approaches are the large numbers and metabolic diversity of microbes associated with roots and found in either soil or other suitable growth media. It is known that most biogeochemical cycles have a microbial link, and the ability of microbes to metabolize virtually all trace gases, whether of technogenic or biogenic origin, have long been established. Wetland plants and soil/media also been extensively researched for their ability to purify wastewaters of all kinds of potential water pollutants, from nutrients like N and P, to heavy metals and a range of complex industrial pollutants. There is a growing body of research on the ability of higher plants to purify air and water. Associated benefits of these approaches is that by utilizing natural ecological processes, the cleansing of air and water can be done with little or no energy inputs. Soil and root microorganisms respond to changing pollutant types by an increase of the types of organisms with the capacity to use these compounds. Thus living systems have an extraordinary adaptive capacity as long as the starting populations are sufficiently diverse. It is known that tightly sealed environments, from office buildings to spacecraft, can have hundreds or even thousands of potential air pollutants, depending on the materials and machines enclosed. Human waste products carry a plethora of microbes can are readily used in the process of converting its organic load to forms that can be utilized by green plants. Having endogenous means of responding to changing air and water quality conditions represents safety factors which operate without the need for human direction. We will

  10. Plants + soil/wetland microbes: Food crop systems that also clean air and water

    Science.gov (United States)

    Nelson, Mark; Wolverton, B. C.

    2011-02-01

    The limitations that will govern bioregenerative life support applications in space, especially volume and weight, make multi-purpose systems advantageous. This paper outlines two systems which utilize plants and associated microbial communities of root or growth medium to both produce food crops and clean air and water. Underlying these approaches are the large numbers and metabolic diversity of microbes associated with roots and found in either soil or other suitable growth media. Biogeochemical cycles have microbial links and the ability of microbes to metabolize virtually all trace gases, whether of technogenic or biogenic origin, has long been established. Wetland plants and the rootzone microbes of wetland soils/media also been extensively researched for their ability to purify wastewaters of a great number of potential water pollutants, from nutrients like N and P, to heavy metals and a range of complex industrial pollutants. There is a growing body of research on the ability of higher plants to purify air and water. Associated benefits of these approaches is that by utilizing natural ecological processes, the cleansing of air and water can be done with little or no energy inputs. Soil and rootzone microorganisms respond to changing pollutant types by an increase of the types of organisms with the capacity to use these compounds. Thus living systems have an adaptive capacity as long as the starting populations are sufficiently diverse. Tightly sealed environments, from office buildings to spacecraft, can have hundreds or even thousands of potential air pollutants, depending on the materials and equipment enclosed. Human waste products carry a plethora of microbes which are readily used in the process of converting its organic load to forms that can be utilized by green plants. Having endogenous means of responding to changing air and water quality conditions represents safety factors as these systems operate without the need for human intervention. We review

  11. 76 FR 76048 - Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards

    Science.gov (United States)

    2011-12-06

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 81 RIN 2060-AR17 Air Quality Designations for the 2008 Lead (Pb) National Ambient Air Quality Standards Correction In rule document 2011-29460 appearing on pages 72097-72120 in the issues of...

  12. 78 FR 30770 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards...

    Science.gov (United States)

    2013-05-23

    ... appropriate, disproportionate human health or environmental effects, using practicable and legally permissible...).) List of Subjects in 40 CFR Part 52 Environmental protection, Air pollution control, Incorporation by... Pollution; Chapter I: Pollution Control Board; Subchapter l: Air Quality Standards And Episodes; Part...

  13. 78 FR 30829 - Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards...

    Science.gov (United States)

    2013-05-23

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Illinois; Air Quality Standards Revision AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: EPA is proposing to approve a revision to the Illinois State Implementation Plan (SIP) to reflect...

  14. Potential exposure to silver nanoparticles during spraying preparation for air-conditioning cleaning

    Directory of Open Access Journals (Sweden)

    Elżbieta Jankowska

    2013-02-01

    Full Text Available Background: Unique properties of engineered nanomaterials (ENMs and products made of them have contributed to a rapid progress in the production and application of ENMs in different branches of industry and in factories with different production scale. Bearing in mind that nano-objects (nanoplates, nanofibres, nanoparticles, emitted during ENM production and application, can cause many diseases, even those not yet recognized, extensive studies have been carried all over the world to assess the extent of exposure to nano-objects at workstations and related health effects in workers employed in ENM manufacture and application processes. Material and Methods: The study of potential exposure to silver nanoparticles contained in the preparation for airconditioning cleaning (Nano Silver from Amtra Sp. z o.o. involved the determination of concentrations and size distribution of particles, using different devices, allowing for tracing changes in a wide range of dimensions, from nano-size (10 nm to micrometrsize (10 µm, of the particles which are usually inhaled by humans. Results and Conclusions: The results of the study shows that even during a short-term spraying of Nano Silver preparation (for 10 s at the distance of 52 cm from the place of preparation spraying - particles of 10 nm-10 µm can be emitted into in the air. During a three-fold preparation spraying in similar conditions differences in concentration increase were observed, but in each case the particles remained in the air for a relatively long time. Med Pr 2013;64(1:57–67

  15. The Effects of Workplace Clean Indoor Air Law Coverage on Workers' Smoking-Related Outcomes.

    Science.gov (United States)

    Cheng, Kai-Wen; Liu, Feng; Gonzalez, MariaElena; Glantz, Stanton

    2017-02-01

    This study investigated the effects of workplace clean indoor air law (CIAL) coverage on worksite compliance with CIALs, smoking participation among indoor workers, and secondhand smoke (SHS) exposure among nonsmoker indoor workers. This study improved on previous research by using the probability of a resident in a county covered by workplace CIALs, taking into account the state, county, and city legislation. The county-level probability of being covered by a CIAL is merged into two large nationally representative US surveys on smoking behaviors: Tobacco Use Supplement of the Current Population Survey (2001-2010) and Behavioral Risk Factor Surveillance System (2000-2006) based on the year of the survey and respondent's geographic location to identify respondents' CIAL coverage. This study estimated several model specifications of including and not including state or county fixed effects, and the effects of workplace CIALs are consistent across models. Increased coverage by workplace CIALs significantly increased likelihood of reporting a complete smoking restriction by 8% and 10% for the two different datasets, decreased smoking participation among indoor workers by 12%, and decreased SHS exposure among nonsmokers by 28%. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Evidence of recovery of Juniperus virginiana trees from sulfur pollution after the Clean Air Act.

    Science.gov (United States)

    Thomas, Richard B; Spal, Scott E; Smith, Kenneth R; Nippert, Jesse B

    2013-09-17

    Using dendroisotopic techniques, we show the recovery of Juniperus virginiana L. (eastern red cedar) trees in the Central Appalachian Mountains from decades of acidic pollution. Acid deposition over much of the 20th century reduced stomatal conductance of leaves, thereby increasing intrinsic water-use efficiency of the Juniperus trees. These data indicate that the stomata of Juniperus may be more sensitive to acid deposition than to increasing atmospheric CO2. A breakpoint in the 100-y δ(13)C tree ring chronology occurred around 1980, as the legacy of sulfur dioxide emissions declined following the enactment of the Clean Air Act in 1970, indicating a gradual increase in stomatal conductance (despite rising levels of atmospheric CO2) and a concurrent increase in photosynthesis related to decreasing acid deposition and increasing atmospheric CO2. Tree ring δ(34)S shows a synchronous change in the sources of sulfur used at the whole-tree level that indicates a reduced anthropogenic influence. The increase in growth and the δ(13)C and δ(34)S trends in the tree ring chronology of these Juniperus trees provide evidence for a distinct physiological response to changes in atmospheric SO2 emissions since ∼1980 and signify the positive impacts of landmark environmental legislation to facilitate recovery of forest ecosystems from acid deposition.

  17. 40 CFR 50.8 - National primary ambient air quality standards for carbon monoxide.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.8 National primary ambient air quality standards for carbon monoxide. (a) The national primary ambient air quality standards... 40 Protection of Environment 2 2010-07-01 2010-07-01 false National primary ambient air...

  18. Determination of the Clean Air Delivery Rate (CADR) of Photocatalytic Oxidation (PCO) Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part II: Experimental Results.

    Science.gov (United States)

    Héquet, Valérie; Batault, Frédéric; Raillard, Cécile; Thévenet, Frédéric; Le Coq, Laurence; Dumont, Éric

    2017-03-06

    The performances of a laboratory PhotoCatalytic Oxidation (PCO) device were determined using a recirculation closed-loop pilot reactor. The closed-loop system was modeled by associating equations related to two ideal reactors: a perfectly mixed reservoir with a volume of VR = 0.42 m³ and a plug flow system corresponding to the PCO device with a volume of VP = 5.6 × 10(-3) m³. The PCO device was composed of a pleated photocatalytic filter (1100 cm²) and two 18-W UVA fluorescent tubes. The Clean Air Delivery Rate (CADR) of the apparatus was measured under different operating conditions. The influence of three operating parameters was investigated: (i) light irradiance I from 0.10 to 2.0 mW·cm(-2); (ii) air velocity v from 0.2 to 1.9 m·s(-1); and (iii) initial toluene concentration C₀ (200, 600, 1000 and 4700 ppbv). The results showed that the conditions needed to apply a first-order decay model to the experimental data (described in Part I) were fulfilled. The CADR values, ranging from 0.35 to 3.95 m³·h(-1), were mainly dependent on the light irradiance intensity. A square root influence of the light irradiance was observed. Although the CADR of the PCO device inserted in the closed-loop reactor did not theoretically depend on the flow rate (see Part I), the experimental results did not enable the confirmation of this prediction. The initial concentration was also a parameter influencing the CADR, as well as the toluene degradation rate. The maximum degradation rate rmax ranged from 342 to 4894 ppbv/h. Finally, this study evidenced that a recirculation closed-loop pilot could be used to develop a reliable standard test method to assess the effectiveness of PCO devices.

  19. A 14-year longitudinal study of the impact of clean indoor air legislation on state smoking prevalence, USA, 1997-2010.

    Science.gov (United States)

    Becker, Craig M; Lee, Joseph G L; Hudson, Suzanne; Hoover, Jeanne; Civils, Donald

    2017-06-01

    While clean indoor air legislation at the state level is an evidence-based recommendation, only limited evidence exists regarding the impact of clean indoor air policies on state smoking prevalence. Using state smoking prevalence data from 1997 to 2010, a repeated measures observational analysis assessed the association between clean indoor air policies (i.e., workplace, restaurant, and bar) and state smoking prevalence while controlling for state cigarette taxes and year. The impacts from the number of previous years with any clean indoor air policy, the number of policies in effect during the current year, and the number of policies in effect the previous year were analyzed. Findings indicate a smoking prevalence predicted decrease of 0.13 percentage points (p=0.03) for each additional year one or more clean indoor air policies were in effect, a predicted decrease of 0.12 percentage points (p=0.09) for each policy in effect in the current year, and a predicted decrease of 0.22 percentage points (p=0.01) for each policy in effect in the previous year on the subsequent year. Clean indoor air policies show measurable associations with reductions in smoking prevalence within a year of implementation above and beyond taxes and time trends. Further efforts are needed to diffuse clean indoor air policies across states and provinces that have not yet adopted such policies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Contamination of Dental Unit Water and Air Outlets Following Use of Clean Head System and Conventional Handpieces

    Directory of Open Access Journals (Sweden)

    Mehrnoosh Sadighi

    2007-06-01

    Full Text Available

    Background and aims. Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces.

    Materials and methods. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p< 0.01 was considered significant.

    Results. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p< 0.01.

    Conclusion. A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

  1. Saving energy in the make-up air unit (MAU) for semiconductor clean rooms in subtropical areas

    Energy Technology Data Exchange (ETDEWEB)

    Tsao, Jhy-Ming; Hu, Shih-Cheng [Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology. 1, Sec. 3, Chung-Hsiao E. Rd. Taipei 106 (China); Chan, David Yih-Liang; Hsu, Rich Tsung-Chi; Lee, Jane Car-Cheng [Energy and Environment Research Labs, Industrial Technology Research Institute Bldg 51, 195, Sec. 4, Chung Hsing Rd, Chutung, Hinchu 106 Taiwan (China)

    2008-07-01

    The energy requirements to cool, dehumidify, preheat and/or humidify outdoor air are significant in the make-up air unit (MAU) of clean room air-conditioning systems, and can represent 30% to 65% of the total thermal energy required to maintain a clean room environment. Because of these high-energy requirements, cost-effective means to reduce energy costs can influence unit production costs. Reducing or displacing mechanical cooling or electrical heating requirements can achieve the greatest opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the MAU system by properly arranging compositions of components of a typical MAU applied in a semiconductor clean room. Explicitly, we investigated the influence of various factors including the fan location (draft-through type vs. push-through type), chilled water system (single-chilled water temperature system vs. two chilled water temperature system) and reheating scheme (electrical heating vs. hot water provided by heat recovery chiller). The result shows that the draw-through type accompanied by two chilled water temperature system with heat recovery function exhibits the lowest electrical power consumption. (author)

  2. Allowance trading under the Clean Air Act: Who should regulate, and when?

    Energy Technology Data Exchange (ETDEWEB)

    Lock, R. [LeBoeuf, Lamb, Leiby & MacRae, Washington, DC (United States)

    1993-07-01

    The goal of this paper is to explore how compliance with the Clean Air Act Amendments of 1990 (CAAA), especially Title IV and emission trading under it, will affect the current relationship between state and federal regulation. It is difficult, with the limited experience we have had under Title IV, to be definitive about or to be a very strong advocate of too many policy positions. What may be most helpful at this point is to identify where the difficult issues in state/federal relations might arise; and then to explore ways in which tensions might be either avoided or resolved. One anticipated conclusion is that a traditional regulatory mindset could be very destructive if applied to this new area of oversight without due sensitivity to what Congress is trying to achieve in Title IV. That concern pervaded the early legislative debates; and it persists today. Title IV presents some unique challenges to state regulators and will require some creative solutions and fresh thinking if the goals of Congress are to be realized and the full benefits that allowance trading can offer are to be reaped by electricity consumers. In the ultimate analysis, Title IV amounts to a massive internalization of the external costs imposed on society by acid rain deposition. (This places in serious question the notion of additional externality {open_quotes}adders{close_quotes} for sulfur dioxide (SO{sub 2}) and nitrous oxide (NO{sub x}) at the state level for utility supply planning purposes.) The whole point of Title IV is to give those directly charged with compliance, namely power producers, the maximum flexibility to pursue least-cost compliance solutions. Perhaps the biggest single factor in how well they do this will be how state regulators respond to their compliance and allowance trading initiatives.

  3. Regulatory policy issues and the Clean Air Act: Issues and papers from the state implementation workshops

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K. [ed.; Burns, R.E.

    1993-07-01

    The National Regulatory Research Institute (NRRI), with funding from the US Environmental Protection Agency (EPA) and the US Department of Energy (DOE), conducted four regional workshops` on state public utility commission implementation of the Clean Air Act Amendments of 1990 (CAAA). The workshops had four objectives: (1) to discuss key issues and concerns on CAAA implementation, (2) to encourage a discussion among states on issues of common interests, (3) to attempt to reach consensus, where possible, on key issues, and (4) to provide the workshop participants with information and materials to assist in developing state rules, orders, and procedures. From the federal perspective, a primary goal was to ensure that workshop participants return to their states with a comprehensive background and understanding of how state commission actions may affect implementation of the CAAA and to be able to provide guidance to their jurisdictional utilities. It was hoped that this would reduce some of the uncertainty utilities face and assist in the development of an efficient allowance market. This report is divided into two main sections. In Section II, eleven principal issues are identified and discussed. These issues were chosen because they were either the most frequently discussed or they were related to the questions asked in response to the speakers` presentations. This section does not cover all the issues relevant to state implementation nor all the issues discussed at the workshops; rather, Section II is intended to provide an overview of the,planning, ratemaking, and multistate issues. Part III is a series of workshop papers presented by some of the speakers. Individual papers have been cataloged separately.

  4. We Care for Clean Air! The Contribution of ACCENT to Education and Communication

    Science.gov (United States)

    Schuepbach, Eva; Brimblecombe, Peter; Gross, Krisjanis; Jacobs, Mark J.; Ladstätter-Weißenmayer, Annette; Moussiopoulos, Nicolas; Slini, Theodora; Übelis, Arnolds; Uherek, Elmar

    2010-05-01

    A new booklet on: "We Care for Clean Air! Motivating the Next Generation of Atmospheric Scientists" (ISBN 978-88-95665-01-6) as recently published by the education community in ACCENT (www.accent-network.org/portal/education) is presented. Promoting creative and innovative researchers and teachers and encouraging the next generation to move into the field were among the key issues in ACCENT "Training and Education" (T&E). During the 5-year programme, a wealth of educational events (e.g., workshops) and programmes (e.g., "ACCENT FAR EAST") were organized and tools developed for teachers and learners at Universities and Schools around the globe. Activities such as National ACCENT Days or Cafés Scientifiques also targeted stakeholders, policy makers and the general public to increase the expertise in atmospheric composition change to a common level across Europe. The volume introduces the integrated learning environment, high-quality tools and methods for air quality and climate change science education created by ACCENT T&E, and provides an overview on the unbiased scientific information that has been didactically translated based on knowledge available from ongoing research projects.The core messages are that (i) the translation of complex issues in atmospheric composition and climate change science to non-scientists should be scientifically acceptable and that (ii) scientists should stay in control of the translation process. After the publication of the 4th Assessment Report of the Intergovernmental Panel for Climate Change (IPCC) in 2007, ACCENT intensified its efforts to reach greater visibility and distribute the body of know-how, skills and competencies within the networked community of atmospheric scientists in the World Wide Web. For example, a Special Issue of the "Global Change Magazine for Schools" on IPCC 2007 contains a compact introduction to the basics of global warming for direct application in the classroom, also focusing on uncertainties and

  5. 77 FR 60341 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Science.gov (United States)

    2012-10-03

    ... Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion... Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines to..., ``National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New...

  6. Improvement of self-cleaning type air filter%自洁式空气过滤器的改进

    Institute of Scientific and Technical Information of China (English)

    王鹏

    2012-01-01

    The self-cleaning type air filter is fitted before air inlet pipe of air compressor completed for air separation plant. The domestic-made carriage has low service life, and in case of highly wet air the filter paper is liable to stick, which lowers the filtering efficiency, results in frequent repair of air compressor repair, and seriously impairs prolonged stable run of air separation plant. The service life of carriage of self-cleaning type air filter is extended and the filtering efficiency is improved through use of the non-woven filtering cotton blended with compound fiber, the carriage made of compound fiber, and the imported filter paper, adjustment of its programmable controller, and change of its back-blowing pressure and air supply. Here, the work principle of self- cleaning type air filter is briefed, the problems during its operation process are analyzed, and the implementation process and economic benefits of the improvement measures are described.%空分设备配套空压机进气管前设置自洁式空气过滤器,由于国内生产的滤筒使用寿命短,遇含湿量大的空气时滤纸易黏连,进而影响过滤效率,导致空压机检修频繁,严重影响了空分设备长周期稳定运行。通过增加复合纤维无纺滤棉,选用复合纤维滤筒和进口滤纸,调整自洁式空气过滤器的编程控制仪,以及改变反吹压力和反吹气源,达到延长自洁式空气过滤器的滤筒寿命和提高过滤效率的目的。简述自洁式空气过滤器的工作原理,分析其使用过程中存在的问题,阐述改进措施的实施过程及取得的经济效益。

  7. Will the circle be unbroken: a history of the U.S. National Ambient Air Quality Standards.

    Science.gov (United States)

    Bachmann, John

    2007-06-01

    In celebration of the 100th anniversary of the Air & Waste Management Association, this review examines the history of air quality management (AQM) in the United States over the last century, with an emphasis on the ambient standards programs established by the landmark 1970 Clean Air Act (CAA) Amendments. The current CAA system is a hybrid of several distinct air pollution control philosophies, including the recursive or circular system driven by ambient standards. Although this evolving system has resulted in tremendous improvements in air quality, it has been far from perfect in terms of timeliness and effectiveness. The paper looks at several periods in the history of the U.S. program, including: (1) 1900-1970, spanning the early smoke abatement and smog control programs, the first federal involvement, and the development of a hybrid AQM approach in the 1970 CAA; (2) 1971-1976, when the first National Ambient Air Quality Standards (NAAQS) were set and implemented; (3) 1977-1993, a period of the first revisions to the standards, new CAA Amendments, delays in implementation and decision-making, and key science/policy/legislative developments that would alter both the focus and scale of air pollution programs and how they are implemented; and (4) 1993-2006, the second and third wave of NAAQS revisions and their implementation in the context of the 1990 CAA. This discussion examines where NAAQS have helped drive implementation programs and how improvements in both effects and air quality/control sciences influenced policy and legislation to enhance the effectiveness of the system over time. The review concludes with a look toward the future of AQM, emphasizing challenges and ways to meet them. The most significant of these is the need to make more efficient progress toward air quality goals, while adjusting the system to address the growing intersections between air quality management and climate change.

  8. Methods for air cleaning and protection of building occupants from airborne pathogens

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor

    2009-01-01

    germicidal irradiation (UVGI), photocatalytic oxidation (PCO), plasmacluster ions and other technologies for air disinfection and purification from pathogens are analyzed with respect to currently used air distribution principles. The importance of indoor air characteristics, such as temperature, relative...

  9. 40 CFR 50.4 - National primary ambient air quality standards for sulfur oxides (sulfur dioxide).

    Science.gov (United States)

    2010-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.4 National primary ambient air quality standards for sulfur oxides (sulfur dioxide). Link to an... applicable to all areas notwithstanding the promulgation of SO2 national ambient air quality standards...

  10. 40 CFR 50.16 - National primary and secondary ambient air quality standards for lead.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for lead. 50.16 Section 50.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.16 National primary and secondary ambient air quality standards for lead. (a) The national primary...

  11. 40 CFR 50.12 - National primary and secondary ambient air quality standards for lead.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for lead. 50.12 Section 50.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.12 National primary and secondary ambient air quality standards for lead. (a) National primary and...

  12. 40 CFR 50.6 - National primary and secondary ambient air quality standards for PM10.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for PM10. 50.6 Section 50.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.6 National primary and secondary ambient air quality standards for PM10. (a) The level of the...

  13. 40 CFR 50.15 - National primary and secondary ambient air quality standards for ozone.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for ozone. 50.15 Section 50.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.15 National primary and secondary ambient air quality standards for ozone. (a) The level of...

  14. Seeing Through Smoke: Sorting through the Science and Politics in the Making of the 1956 British Clean Air Act (Invited)

    Science.gov (United States)

    Kenny, D. A.

    2010-12-01

    The 1952 “Killer Smog” left over 4000 citizens of Greater London dead in a single week. It was a highly visible environmental disaster, which pinned the British government with responsibility over factory and domestic coal smoke pollution. Within four years of the Smog, the British parliament passed the 1956 Clean Air Act, which was designed primarily to prevent the release of dark smoke from the chimneys of private dwellings and factories. This act is considered a significant turning point in the history of environmental regulation. Through the analysis of confidential documents from government ministries and Members of Parliament, my research has focused on how decisions were made following this man-made environmental catastrophe. The primary focus of this presentation will be to explore why the British government appeared lethargic in the face of its long-standing coal pollution problem and why it finally passed the first clean air act in the world. In this case, establishing responsibility and organizing research were the major time constraints on policy action. In the months following the 1952 Smog, government departments passed off responsibility and quarreled over jurisdiction in the smog matter. Ministries held responsible for air pollution jointly established the Committee on Air Pollution to find a solution to urban smog. In the years following, the Committee on Air Pollution compiled research on the health effects and economic impact of air pollution, deriving its information from a variety of sources. In its 1954 final report, the committee named smoke and sulfur dioxide the most likely culprits of the 1952 deaths, and it recommended the elimination of smoke-producing coal from the British market, a major change to how the British fueled their homes and factories. The resulting 1956 Clean Air Act was the product of numerous compromises over the economic, political, and social issues present in Great Britain at the time. The British government

  15. Robust self-cleaning surfaces that function when exposed to either air or oil

    OpenAIRE

    Lu, Y.

    2015-01-01

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to va...

  16. Technical comments on EPA`s proposed revisions to the National Ambient Air Quality Standard for particulate matter

    Energy Technology Data Exchange (ETDEWEB)

    Lipfert, F.W.

    1997-03-01

    The US Environmental Protection Agency (EPA) has proposed new ambient air quality standards specifically for fine particulate matter, regulating concentrations of particles with median aerodynamic diameters less than 2.5 {mu}m (PM{sub 2.5}). Two new standards have been proposed: a maximum 24-hr concentration that is intended to protect against acute health effects, and an annual concentration limit that is intended to protect against longer-term health effects. EPA has also proposed a slight relaxation of the 24-hr standard for inhalable particles (PM{sub 10}), by allowing additional exceedances each year. Fine particles are currently being indirectly controlled by means of regulations for PM{sub 10} and TSP, under the Clean Air Act of 1970 and subsequent amendments. Although routine monitoring of PM{sub 2.5} is rare and data are sparse, the available data indicate that ambient concentrations have been declining at about 6% per year under existing regulations.

  17. Clean Air for Anchorage and Fairbanks: Curriculum for Grades 1-6.

    Science.gov (United States)

    South East Regional Resource Center, Juneau, AK.

    Through the 10 lessons in this guide, elementary school students can be introduced to the characteristics of air, methods of air pollution control, air movement, and the health effects of polluted air. A directory of field trip sites and a list of teacher resources is included. Contained in each lesson plan are a materials list, general…

  18. An empirical bayes method for comparing air pollution data to air quality standards

    Science.gov (United States)

    Suggs, Jack C.; Curran, Thomas C.

    Air pollution concentrations are often characterized by skewed distributions. For example, 24-h suspended particulate mass concentrations have historically been characterized by a 2-parameter lognormal distribution (Larsen, 1969, J. Air. Pollut. Control. Ass.19, 24-30). The error in making measurements of these concentrations also conforms to a distribution that is more symmetric and can usually be approximated by the normal distribution, often with the added feature that the error variation is a function of concentration level. Air pollution measurements are often used to determine status with respect to legal standards such as the National Ambient Air Quality Standards (NAAQS) (Fed. Reg. 36, 8186, 1971; 44, 8202, 1979). In general, these standards do not explicitly account for measurement error. Using Bayesian mathematics, a model is developed which deals with the probability of the "true" concentration exceeding the NAAQS given a measurement above the NAAQS. Several hypothetical examples are used to demonstrate that Bayesian techniques can combine both pollution history and instrument precision into a probablistic model for comparing air pollution data to NAAQS.

  19. Negative pressure of the environmental air in the cleaning area of the materials and sterilization center: a systematic review.

    Science.gov (United States)

    Ciofi-Silva, Caroline Lopes; Hansen, Lisbeth Lima; Almeida, Alda Graciele Claudio Dos Santos; Kawagoe, Julia Yaeko; Padoveze, Maria Clara; Graziano, Kazuko Uchikawa

    2016-09-01

    to analyze the scientific evidence on aerosols generated during cleaning activities of health products in the Central Service Department (CSD) and the impact of the negative pressure of the ambient air in the cleaning area to control the dispersion of aerosols to adjacent areas. for this literature systematic review the following searches were done: search guidelines, manuals or national and international technical standards given by experts; search in the portal and databases PubMed, Scopus, CINAHL and Web of Science; and a manual search of scientific articles. the five technical documents reviewed recommend that the CSD cleaning area should have a negative differential ambient air pressure, but scientific articles on the impact of this intervention were not found. The four articles included talked about aerosols formed after the use of a ultrasonic cleaner (an increased in the contamination especially during use) and pressurized water jet (formation of smaller aerosols 5μm). In a study, the aerosols formed from contaminated the hot tap water with Legionella pneumophila were evaluated. there is evidence of aerosol formation during cleanup activities in CSD. Studies on occupational diseases of respiratory origin of workers who work in CSD should be performed. analisar as evidências científicas sobre aerossóis gerados durante atividades de limpeza dos produtos para saúde no Centro de Material e Esterilização (CME) e o impacto da pressão negativa do ar ambiente na área de limpeza para controle da dispersão de aerossóis para áreas adjacentes. para essa revisão sistemática de literatura foram realizadas: busca de diretrizes, manuais ou normas técnicas nacionais e internacionais indicadas por especialistas; busca no portal e bases de dados PUBMED, SCOPUS, Cinahl e Web of Science; e busca manual de artigos científicos. Os cinco documentos técnicos analisados preconizam que na área de limpeza do CME haja diferencial negativo de pressão do ar ambiente

  20. 77 FR 11390 - Delegation of National Emission Standards for Hazardous Air Pollutants for Source Categories; Nevada

    Science.gov (United States)

    2012-02-27

    ... Clean Air Act, as amended in 1990 (CAA), authorizes EPA to delegate to State or local air pollution... Portland Cement Manufacturing Industry, as set forth in 75 FR 54970 (September 9, 2010). The amendments to... for Aluminum, Copper, and Other Nonferrous Foundries. ] Subpart AAAAAAA--NESHAP for Area Sources...

  1. Effects of indoor air purification by an air cleaning system (Koala technology) on semen parameters in male factor infertility: results of a pilot study.

    Science.gov (United States)

    Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S

    2009-06-01

    A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment.

  2. Robust self-cleaning surfaces that function when exposed to either air or oil

    Science.gov (United States)

    Lu, Yao; Sathasivam, Sanjayan; Song, Jinlong; Crick, Colin R.; Carmalt, Claire J.; Parkin, Ivan P.

    2015-03-01

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to various substrates and promote robustness. These surfaces maintained their water repellency after finger-wipe, knife-scratch, and even 40 abrasion cycles with sandpaper. The formulations developed can be used on clothes, paper, glass, and steel for a myriad of self-cleaning applications.

  3. Repellent materials. Robust self-cleaning surfaces that function when exposed to either air or oil.

    Science.gov (United States)

    Lu, Yao; Sathasivam, Sanjayan; Song, Jinlong; Crick, Colin R; Carmalt, Claire J; Parkin, Ivan P

    2015-03-06

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to various substrates and promote robustness. These surfaces maintained their water repellency after finger-wipe, knife-scratch, and even 40 abrasion cycles with sandpaper. The formulations developed can be used on clothes, paper, glass, and steel for a myriad of self-cleaning applications.

  4. 75 FR 1770 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-01-13

    ... Health and Environment, Air Pollution Division, to the Public Service of Colorado to operate the Hayden... Department of Public Health and Environment, Air Pollution Division, to the Public Service of Colorado...

  5. 77 FR 5518 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-02-03

    ... Public Health and Environment, Air Pollution Division, to CF&I Steel, d/b/a EVRAZ Rocky Mountain Steel... by the Colorado Department of Public Health and Environment, Air Pollution Division, to CF&I Steel,...

  6. 77 FR 54382 - Revisions of Five California Clean Air Act Title V Operating Permits Programs

    Science.gov (United States)

    2012-09-05

    ... pollution control, Carbon dioxide, Carbon dioxide equivalents, Greenhouse gases, Hydrofluorocarbons... revisions to the Operating Permits (Title V) programs of the Monterey Bay Unified Air Pollution Control District (MBUAPCD), San Luis Obispo County Air Pollution Control District (SLOCAPCD), Santa Barbara...

  7. Preliminary calculations for the CAFE project (Clean Air For Europe); Calculs preparatoires pour la strategie thematique CAFE (Clean Air For Europe)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    The European Commission decided in 2001 an analysis program to reduce the atmospheric emissions. This report presents different limit scenari for France in 2020 (the reference scenari and the MTFR scenari, Maximum Technically Feasible Reduction), optimized scenari calculated by the RAINS model (Regional Air Pollution Information and Simulation), the costs of the scenari calculated with RAINS and the cost-benefit analysis of the strategy CAFE. From the study results, the benefits are higher than the costs, even with the most ambitious scenari. At an european level the emission reduction strategies have no effect on the employment but an impact on the Gross Domestic Product (decrease between 0,04 % and 0,12 % in function of the scenari). (A.L.B.)

  8. CLEAN-ROADS project: air quality considerations after the application of a novel MDSS on winter road maintenance activities

    Science.gov (United States)

    Pretto, Ilaria; Malloci, Elisa; Tonidandel, Gabriele; Benedetti, Guido; Di Napoli, Claudia; Piazza, Andrea; Apolloni, Roberto; Cavaliere, Roberto

    2016-04-01

    With this poster we present the environmental benefit on air quality derived by the application of the CLEAN-ROADS pilot project. The CLEAN-ROADS project addresses the problem of the environmental pollution caused by de-icing salts during winter road maintenance activities in the Province of Trento (Italy). A demonstrative Maintenance Decision Support System (MDSS) has been developed in order to improve the intervention procedures of the road management service. Specifically it aims to optimize the efficiency of how available resources (e.g., salt consumption) are currently used while guaranteeing the current level of road safety. The CLEAN-ROADS project has been tested and validated on a test area located in a valley bottom (Adige Valley), where the highest optimization margins are to be expected. The project supports current road maintenance practices, which has proved to be reliable and accurate, with a new scalable and energy-efficient road monitoring system. This system is based on a network of road weather stations (road weather information system, RWIS) installed on the test route. It is capable to collect real-time data about the road conditions and to perform short-term and now-cast road weather forecasts, which actively integrate weather data and bulletins covering the target area [1]. This poster presents the results obtained from a three-year monitoring activity with the aim to (1) determine the impact of de-icing salts on air quality and (2) quantify the improvements obtained by the application of the CLEAN-ROADS project on air quality. The Ambient Air Quality and Cleaner Air for Europe Directive (2008/50/EC) states that contributions to exceedances of particulate matter PM10 limit values that are attributable to road winter salting may be subtracted when assessing compliance with air quality limit values, once provided that reasonable measures have been taken to lower concentrations [2]. As the de-icing salts used in road maintenance are mainly based

  9. Eliminating second-hand smoke from Mexican-American households: outcomes from Project Clean Air-Safe Air (CASA).

    Science.gov (United States)

    Prokhorov, Alexander V; Hudmon, Karen Suchanek; Marani, Salma K; Bondy, Melissa L; Gatus, Leticia A; Spitz, Margaret R; Wilkinson, Anna V; Hammond, S Katharine; Koehly, Laura M

    2013-01-01

    Exposure to second-hand smoke (SHS) is a major public health problem and a risk factor for morbidity and mortality. The objective of this randomized trial was to estimate the impact of a culturally-sensitive intervention to reduce SHS exposure in Mexican-American households. A total of 91 households (with a child under 18 years of age and two adults, one of whom was a smoker) were recruited from a population-based cohort of Mexican-American households and randomized to receive the experimental intervention (EI; n=47) or standard care (SC; n=44). Of these, 74 households (83%) provided baseline, 6-month, and 12-month survey and nicotine monitor data (EI, n=39; SC, n=35). The EI materials, designed to increase the participants' likelihood of adopting a smoke-free indoor home air policy, included one culturally-appropriate bilingual comic book for children and two fotonovelas for adults. Ambient nicotine levels significantly decreased over the 12 study months (F=13.6, DF=147; peffects of SHS increased from baseline to 6 and 12 months in the EI condition but not in the SC condition (F=6.0, DF=238; p<0.01), and smokers and quitters in the EI group reported an increased perception of health vulnerability compared to those in the SC group. Our low-cost intervention impacted SHS-related knowledge and exposure among Mexican Americans. This culturally-appropriate intervention has the potential to decrease SHS-related health problems in the target population substantially. Published by Elsevier Ltd.

  10. 78 FR 44485 - Implementation of the 2008 National Ambient Air Quality Standards for Ozone: State Implementation...

    Science.gov (United States)

    2013-07-24

    ... AGENCY 40 CFR Parts 50, 51, 70 and 71 Implementation of the 2008 National Ambient Air Quality Standards... on this rulemaking, contact Dr. Karl Pepple, Office of Air Quality Planning and Standards, U.S... Stackhouse, Office of Air Quality Planning and Standards, U.S. Environmental Protection Agency, by phone...

  11. 78 FR 34964 - Implementation of the 2008 National Ambient Air Quality Standards for Ozone: State Implementation...

    Science.gov (United States)

    2013-06-11

    ... AGENCY 40 CFR Parts 50, 51, 70 and 71 Implementation of the 2008 National Ambient Air Quality Standards... proposed rule ``Implementation of the 2008 National Ambient Air Quality Standards for Ozone: State... proposed rulemaking proposes to implement the 2008 ozone national ambient air quality standards...

  12. Information draft on the development of air standards for acrylonitrile

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    Acrylonitrile is a colourless liquid with a faintly sweet and pungent odour. It is widely used as a chemical intermediate in a variety of industrial and commercial products such as acrylic and modacrylic fibres, plastics, styrene-acrylonitrile, nitrile rubber resins, and acrylamide. Although not currently produced in Canada, acrylonitrile is used in the manufacture of industrial and commercial products. Acrylonitrile levels around end-use plants have been found to be significantly higher than at producing facilities. Almost all releases of acrylonitrile are to the atmosphere and one facility is responsible for all releases in Ontario. Human exposure is through air, water and food. Acrylonitrile is absorbed by inhalation, through the mouth and to some extent through the skin. Exposure at concentrations of 7 to 45 microgram/cubic meter for 20 to 45 minutes leads to irritation of the mucous membranes, nausea, headaches, and irritability. Low-grade anaemia, leukocytosis, kidney irritation and mild jaundice have also been observed. Children are more sensitive than adults. Acrylonitrile is classified as probable human carcinogen by the US Environmental Protection Agency. The current ambient air quality criterion (AAQC) in Ontario is 100 microgram/cubic metre and the half-hour interim point of impingement (POI) standard is 300 microgram/cubic meter. Review of world-wide literature showed the existence of standards in several American states. Cancer unit risks estimates have been made by the US Environmental Protection Agency as well as by the World Health Organization. 63 refs., 1 tab., appendix.

  13. Toxaphene in standard solutions and cleaned biota extract-results of the first QUASIMEME interlaboratory studies

    NARCIS (Netherlands)

    Boer, de J.; Oehme, M.; Smith, K.; Wells, D.E.

    2000-01-01

    Two interlaboratory studies on individual toxaphene congeners have been organised by the project Quality Assurance of Information for Marine Environmental Monitoring in Europe (QUASIMEME). Fifteen laboratories analysed two standard solutions in the first study and 13 laboratories analysed a standard

  14. Nonattainment of national ambient air quality standards: implications for energy policy

    Energy Technology Data Exchange (ETDEWEB)

    Garvey, D.B.; Streets, D.G.; Kotecki, R.; Senew, M.

    1979-10-01

    In accordance with the 1977 Clean Air Act Amendments, EPA established regulations governing new and existing sources of emissions in areas where the NAAQS are being exceeded. These requirements may constrain the implementation of a national energy policy to increase the use of coal in utilities and industries. The states designated the nonattainment areas and prepared State Implementation Plans, outlining strategies for attaining the standards by the deadline of December 31, 1982. This report contains maps of nonattainment areas for all pollutants and summaries of the attainment strategies for those pollutants most likely to affect fossil-fueled energy development - SO/sub 2/, TSP, and NO/sub x/. The review of SIPs indicates that attainment of SO/sub 2/ standards should be relatively easy. Attainment of TSP standards may be more difficult since point sources are already well controlled and further reductions in emissions will require controls on fugitive sources. NO/sub x/ nonattainment is currently limited to three small areas. The report also contains an examination of emission limitations in nonattainment areas and a national assessment of the potential constraints of nonattainment on energy development in 1985 to 1990. The assessment concludes that constraints on projected new coal-fired utilities should not be significant. Constraints on expanded industrial coal use from TSP nonattainment may be significant but the effects of SO/sub 2/ nonattainment should be limited.

  15. 3D Air Quality and the Clean Air Interstate Rule: Lagrangian Sampling of CMAQ Model Results to Aid Regional Accountability Metrics

    Science.gov (United States)

    Fairlie, T. D.; Szykman, Jim; Pierce, Robert B.; Gilliland, A. B.; Engel-Cox, Jill; Weber, Stephanie; Kittaka, Chieko; Al-Saadi, Jassim A.; Scheffe, Rich; Dimmick, Fred; hide

    2008-01-01

    The Clean Air Interstate Rule (CAIR) is expected to reduce transport of air pollutants (e.g. fine sulfate particles) in nonattainment areas in the Eastern United States. CAIR highlights the need for an integrated air quality observational and modeling system to understand sulfate as it moves in multiple dimensions, both spatially and temporally. Here, we demonstrate how results from an air quality model can be combined with a 3d monitoring network to provide decision makers with a tool to help quantify the impact of CAIR reductions in SO2 emissions on regional transport contributions to sulfate concentrations at surface monitors in the Baltimore, MD area, and help improve decision making for strategic implementation plans (SIPs). We sample results from the Community Multiscale Air Quality (CMAQ) model using ensemble back trajectories computed with the NASA Langley Research Center trajectory model to provide Lagrangian time series and vertical profile information, that can be compared with NASA satellite (MODIS), EPA surface, and lidar measurements. Results are used to assess the regional transport contribution to surface SO4 measurements in the Baltimore MSA, and to characterize the dominant source regions for low, medium, and high SO4 episodes.

  16. 1999 INEEL National Emission Standards for Hazardous Air Pollutants - Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    J. W. Tkachyk

    2000-06-01

    Under Section 61.94 of Title 40, Code of Federal Regulations (CFR), Part 61, Subpart H, ''National Emission Standards for Emission of Radionuclides Other Than Radon From Department of Energy Facilities,'' each Department of Energy (DOE) facility must submit an annual report documenting compliance. This report addresses the Section 61.94 reporting requirements for operations at the Idaho National Engineering and Environmental Laboratory (INEEL) for calendar year (CY) 1999. The Idaho Operations Office of the DOE is the primary contract concerning compliance with the National Emission Standards for Hazardous Air Pollutants (NESHAPs) at the INEEL. For CY 1999, airborne radionuclide emissions from the INEEL operations were calculated to result in a maximum individual dose to a member of the public of 7.92E-03 mrem (7.92E-08 Sievert). This effective dose equivalent (EDE) is well below the 40 CFR 61, Subpart H, regulatory standard of 10 mrem per year (1.0E-04 Sievert per year).

  17. Clean Air for Anchorage and Fairbanks: Curriculum for Grades 7-12.

    Science.gov (United States)

    South East Regional Resource Center, Juneau, AK.

    Ten lessons on air and air pollution comprise this guide for secondary school teachers. Among the topics addressed are pollutants, health effects, weather inversions, personal involvement, and automobile emissions. Particular emphasis is placed upon problems in Alaskan cities. Lesson plans contain a materials list, background information,…

  18. Information draft on the development of air standards for methanol

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    Methanol is a clear, colourless. very mobile liquid with a slightly alcoholic odour in pure form, but a repulsive pungent odour in crude form. Methanol is the raw material in the production of many gasoline additives, is used as a solvent or antifreeze in paint strippers, aerosol spray paints, wall paints, carburetor cleaners, and car windshield washer compounds. Methanol is one of the top pollutants by release quantities in Ontario, the highest release being generated by the pulp and paper industry. Other large emissions come from the plastics and synthetic resin industry. Total release to the air in Canada was 3,668 tonnes in 1996 and the top ten methanol emitting facilities were in Ontario. Methanol is readily absorbed through inhalation, ingestion and skin exposures. Once absorbed, it is oxidized to formaldehyde and then to formic acid. Common symptoms of exposure are visual disturbances, dizziness, nausea, vertigo, pain in the extremities, and headaches. No information was found as to the carcinogenicity of methanol to humans or animals. Current Ontario half-hour POI standard for methanol is 84,000 microgram/cubic meter and the 24-hour AAQC is 28,000 microgram/cubic meter. Both values were established more than 20 years ago. Review of relevant literature, summarized in this report, indicates that five US states have promulgated air quality guidelines or reference exposure levels for methanol, based on occupational exposure limits. The US Environmental Protection Agency is currently reviewing its reference concentration value for methanol. The World Health Organization and the Canadian federal government have not set air quality guidelines for methanol. 37 refs., 1 tab., appendix.

  19. Acidic precipitation: considerations for an air-quality standard

    Energy Technology Data Exchange (ETDEWEB)

    Evans, L.S.; Hendrey, G.R.; Stensland, G.J.; Johnson, D.W.; Francis, A.J.

    1980-01-01

    Acidic precipitation, wet or frozen deposition with a hydrogen ion concentration greatern than 2.5 ..mu..eq l/sup -1/ is a significant air pollution problem in the United States. The chief anions accounting for the hydrogen ions in rainfall are nitrate and sulfate. Agricultural systems are more likely to derive net nutritional benefits from increasing inputs of acidic rain than are forest systems when soils alone are considered. Agricultural soils may benefit because of the high N and S requirements of agricultural plants. Detrimental effects to forest soils may result if atmospheric H/sup +/ inputs significantly add to or exceed H/sup +/ production by soils. Acidification of fresh waters of southern Scandinavia, southwestern Scotland, southeastern Canada, and northeastern United States is caused by acid deposition. Areas of these regions in which this acidification occurs have in common, highly acidic precipitation with volume weighted mean annual H/sup +/ concentrations of 25 ..mu..eq l/sup -1/ or higher and slow weathering granitic or precambrian bedrock with thin soils deficient in minerals which would provide buffer capacity. Biological effects of acidification of fresh waters are detectable below pH 6.0. As lake and stream pH levels decrease below pH. 6.0, many species of plants, invertebrates, and vertebrates are progressively eliminated. Generally, fisheries are impacted below pH 5.0 and are completely destroyed below pH 4.8. There are few studies that document effects of acidic precipitation on terrestrial vegetation to establish an air quality standard. It must be demonstrated that current levels of precipitation acidity alone significantly injure terrestrial vegetation. In terms of documented damanges, current research indicates that establishing a standard for precipitation for the volume weighted annual H/sup +/ concentration at 25 ..mu..eq l/sup -1/ may protect the most sensitive areas from permanent lake acidification.

  20. 78 FR 54606 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Science.gov (United States)

    2013-09-05

    ... Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion... emission standards for hazardous air pollutants for stationary reciprocating internal combustion engines and the standards of performance for stationary internal combustion engines. Subsequently, the EPA...

  1. Market effects of environmental regulation: coal, railroads, and the 1990 Clean Air Act

    Energy Technology Data Exchange (ETDEWEB)

    Busse, M.R.; Keohane, N.O. [University of California Berkeley, Berkeley, CA (United States)

    2007-01-01

    Many environmental regulations encourage the use of 'clean' inputs. When the suppliers of such an input have market power, environmental regulation will affect not only the quantity of the input used but also its price. We investigate the effect of the Title IV emissions trading program for sulfur dioxide on the market for low-sulfur coal. We find that the two railroads transporting coal were able to price discriminate on the basis of environmental regulation and geographic location. Delivered prices rose for plants in the trading program relative to other plants, and by more at plants near a low-sulfur coal source.

  2. Cleaning up the air: effectiveness of air quality policy for SO2 and NOx emissions in China

    Science.gov (United States)

    van der A, Ronald J.; Mijling, Bas; Ding, Jieying; Elissavet Koukouli, Maria; Liu, Fei; Li, Qing; Mao, Huiqin; Theys, Nicolas

    2017-02-01

    Air quality observations by satellite instruments are global and have a regular temporal resolution, which makes them very useful in studying long-term trends in atmospheric species. To monitor air quality trends in China for the period 2005-2015, we derive SO2 columns and NOx emissions on a provincial level with improved accuracy. To put these trends into perspective they are compared with public data on energy consumption and the environmental policies of China. We distinguish the effect of air quality regulations from economic growth by comparing them relatively to fossil fuel consumption. Pollutant levels, per unit of fossil fuel, are used to assess the effectiveness of air quality regulations. We note that the desulfurization regulations enforced in 2005-2006 only had a significant effect in the years 2008-2009, when a much stricter control of the actual use of the installations began. For national NOx emissions a distinct decreasing trend is only visible from 2012 onwards, but the emission peak year differs from province to province. Unlike SO2, emissions of NOx are highly related to traffic. Furthermore, regulations for NOx emissions are partly decided on a provincial level. The last 3 years show a reduction both in SO2 and NOx emissions per fossil fuel unit, since the authorities have implemented several new environmental regulations. Despite an increasing fossil fuel consumption and a growing transport sector, the effects of air quality policy in China are clearly visible. Without the air quality regulations the concentration of SO2 would be about 2.5 times higher and the NO2 concentrations would be at least 25 % higher than they are today in China.

  3. 76 FR 58808 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-09-22

    ... CONTACT: Geoffrey L. Wilcox, Air and Radiation Law Office (2344A), Office of General Counsel, U.S...; fax number (202) 564-5601; e-mail address: wilcox.geoffrey@epa.gov . SUPPLEMENTARY INFORMATION:...

  4. 76 FR 71027 - Proposed Settlement Agreements, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-11-16

    ... of the Colorado Department of Public Health and Environment, Air Pollution Control Division regarding... Department of Public Health and Environment regarding the issuance of a renewed title V permit for...

  5. 78 FR 60280 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-10-01

    ... above. FOR FURTHER INFORMATION CONTACT: Susmita Dubey, Air and Radiation Law Office (2344A), Office of...; telephone: (202) 564-5577; fax number (202) 564-5603; email address: dubey.susmita@epa.gov . SUPPLEMENTARY...

  6. How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.

    Science.gov (United States)

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research.

  7. Qualitative Analysis and Study of the Microorganisms in Clean Air within Clean Room of the Pharmaceutical Industry%医药工业洁净室洁净空气微生物定性分析与探讨

    Institute of Scientific and Technical Information of China (English)

    吕洪浩; 李俊杰; 徐慰倬

    2012-01-01

    ObjGCtive To study the distribution of the microorganisms in clean air within clean room of the pharmaceutical industry. Methods Test method for settling microbe was used in the clean air of some clean rooms. The microorganisms isolated were analysed by morphological observation, physiological and biochemical tests and 16S rDNA sequence analysis. Results A strain of actinomycete, four strains of fungi and ten strains of bacteria were derived in the experiment. Conclusion The clean air mainly consists of bacteria, a small amount of fungi and actinomycetes. Professionals of enterprise should master the distribution of bacteria, fungi and actinomycetes, analyze the causes of formation of the colony forming unit and take targeted methods of control for the environment of the clean room to guarantee the quality of products.%目的 探讨医药工业洁净室洁净空气中微生物分布情况.方法 对部分洁净室洁净空气进行沉降菌检测,采用形态学观察,生理生化反应检测以及16S rDNA序列测定等技术对微生物进行分析.结果 通过实验共获得放线菌1株,真菌4株,细菌10株.结论 一般洁净空气中以细菌为主,有少量真菌及放线菌,企业生产者应掌握这些菌的分布情况,分析这些菌落形成的原因,对洁净室环境做出针对性控制手段以保证产品质量.

  8. 76 FR 36120 - Science Advisory Board Staff Office Notification of a Public Meeting of the Clean Air Scientific...

    Science.gov (United States)

    2011-06-21

    ... on EPA's Review of the National Ambient Air Quality Standards for Lead: Risk and Exposure Assessment... that are important to the design and scope of exposure and risk assessments, as well as other aspects...: Risk and Exposure Assessment Planning Document. DATES: The CASAC Lead Review Panel meeting will be...

  9. Removal of NO2 and O3 generated from corona discharge in indoor air cleaning with MnO2 catalyst

    Science.gov (United States)

    Ge, H.; Yu, R.; Mi, D.; Zhu, Y. M.

    2013-03-01

    The production rules and removal efficiency of harmful byproducts such as NO2 and O3 generated from DC corona discharge in indoor air cleaning were investigated. The production behaviours of NO2 and O3 and the relationship between the amount of catalyst (MnO2) and the removal rate of harmful byproducts were experimentally studied. Further, indoor application tests were carried out in a closed room with 90 m3. The results showed that the concentrations of NO2 and O3 produced by corona discharge linearly increased with discharge time. The NO2 yield is larger than O3 by almost one order of magnitude under the same discharge power. To satisfy the demand of Standard of Indoor Air Quality (GB/T18883-2002), the power consumption of unit volume should be less than 1 W m-3 and the catalyst MnO2 consumptions in positive-negative corona discharge were 200 cm3 W-1 and 100 cm3 W-1, respectively.

  10. Standard Practice for Preparing Aircraft Cleaning Compounds, Liquid-Type, Temperature-Sensitive, or Solvent-Based, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers the determination of the stability in storage of liquid enzyme-based, terpene-based, and solvent-based chemical cleaning compounds used to clean the exterior surfaces of aircraft. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. HVAC--the importance of clean intake section and dry air filter in cold climate.

    Science.gov (United States)

    Hanssen, S O

    2004-01-01

    HVAC systems, if properly designed, installed, operated and maintained, will improve thermal conditions and air quality indoors. However, the success strongly depends on the design of the system and the quality of the components we use in our HVAC installations. Regrettably, several investigations have revealed that many HVAC installations have a lot of operational and maintenance problems, especially related to moisture, rain and snow entrainment. In short, it seems that too little attention is placed on the design of the intake section, despite the fact that there exists a large number of national and international guidelines and recommendations. This is a serious problem because the air intake is the initial component of the ventilation plant and as such the first line of defense against debris and other outdoor air pollutants. Unfortunately, the design is often an argued compromise between the architect, the civil engineer and the HVAC engineer. In the future, the technical, hygienic and microbiological feature of air intakes must be better ensured in order to avoid the air intake becoming a risk component as regards contamination and indoor air quality. Further, it seems that the magnitude of the problem is not well known, or recognized, by the building designers, engineers and professionals involved in the construction and operation of buildings. This fact needs to be addressed more seriously, because obviously there is a big difference between the idealistic architectonic design, engineering intentions and the real life situation. Several practical recommendations for design and operation of HVAC systems are presented. Following the recommendations will result in less pollution from the HVAC-system and increased indoor environmental quality.

  12. A review of the current geographic distribution of and debate surrounding electronic cigarette clean air regulations in the United States.

    Science.gov (United States)

    Kadowaki, Joy; Vuolo, Mike; Kelly, Brian C

    2015-01-01

    In this article, we present the results of a systematic review of state, county, and municipal restrictions on the use of electronic cigarettes (e-cigarettes) in public spaces within the United States, alongside an overview of the current legal landscape. The lack of federal guidance leaves lower-level jurisdictions to debate the merits of restrictions on use in public spaces without sufficient scientific research. As we show through a geographic assessment of restrictions, this has resulted in an inconsistent patchwork of e-cigarette use bans across the United States of varying degrees of coverage. Bans have emerged over time in a manner that suggests a "bottom up" diffusion of e-cigarette clean air policies. Ultimately, the lack of clinical and scientific knowledge on the risks and potential harm reduction benefits has led to precautionary policymaking, which often lacks grounding in empirical evidence and results in spatially uneven diffusion of policy.

  13. The effects of Title IV of the Clean Air Act amendments of 1990 on electric utilities: An update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This report presents data and analyses related to Phase I implementation of the Clean Air Act Amendment by electric utilities. It describes the strategies used to comply with the Acid Rain Program in 1995, the effect of compliance on sulfur dioxide emissions levels, the cost of compliance, and the effects of the program on coal supply and demand. The first year of Phase I demonstrated that the market-based sulfur dioxide emissions control system could achieve significant reductions in emissions at lower than expected costs. Some utilities reduced aggregate emissions below legal requirements due to economic incentives; other utilities purchased additional allowances to avoid noncompliance. More than half of the utilities switched to or blended with lower sulfur coal, due to price reductions in the coal market which were partially due to the allowance trading program. 21 figs., 20 tabs.

  14. 77 FR 44544 - Approval and Promulgation of Air Quality Implementation Plans; Utah; Determination of Clean Data...

    Science.gov (United States)

    2012-07-30

    ... Coso Junction, California, and 75 FR 6571 (February 10, 2010), the determination of attainment of the 1..., 2007) (Miami, Arizona area); 75 FR 27944 (May 19, 2010) (Coso Junction, California area); and 76 FR... promulgated secondary PM 10 standards that were identical to the primary standards. See 52 FR 24634 (July...

  15. 76 FR 77226 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-12-12

    ... June 3, 2011, Plaintiffs filed a complaint alleging that EPA failed to promulgate Federal... to promulgate a FIP by May 31, 2012 for VOC RACT rules for the 1997 8-hour ozone standard for all of the State and NOx RACT rules for the 1997 8-hour ozone standard for all of the State except...

  16. 75 FR 38519 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-07-02

    ...-00946 PJH (N.D. C.A.). On March 5, 2010, Plaintiff filed a complaint to compel the U. S. Environmental... County Air Pollution Control District Rule 420'' (Imperial Rule 420), a State implementation plan (SIP... Rule 420. In addition, the proposed consent decree requires that following signature on such notice...

  17. 78 FR 27234 - Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC...

    Science.gov (United States)

    2013-05-09

    ... Development of the Integrated Science Assessment (ISA) for NOX--Health Criteria. DATES: The public teleconference will be held on Wednesday, June 5, 2013 from 1:00 p.m. to 4:00 p.m. (Eastern Time). Location: The... on the scientific and technical aspects of issues related to the criteria for air quality...

  18. 76 FR 44829 - Federal Motor Vehicle Safety Standards; Air Brake Systems

    Science.gov (United States)

    2011-07-27

    ... Administration 49 CFR Part 571 [Docket No. NHTSA-2009-0175] RIN 2127-AK84 Federal Motor Vehicle Safety Standards... published a final rule that amended the Federal motor vehicle safety standard for air brake systems by... Federal Motor Vehicle Safety Standard (FMVSS) No. 121, Air Brake Systems, to require improved...

  19. 78 FR 10005 - National Emission Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing...

    Science.gov (United States)

    2013-02-12

    ... Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing Industry and Standards of Performance for Portland Cement Plants; Final Rule #0;#0;Federal Register / Vol. 78 , No. 29 / Tuesday... RIN 2060-AQ93 National Emission Standards for Hazardous Air Pollutants for the Portland...

  20. 77 FR 42367 - National Emission Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing...

    Science.gov (United States)

    2012-07-18

    ... Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing Industry and Standards of Performance for Portland Cement Plants; Proposed Rule #0;#0;Federal Register / Vol. 77 , No. 138 / Wednesday...-AQ93 National Emission Standards for Hazardous Air Pollutants for the Portland Cement...

  1. 用标准传热系数评价凝汽器水侧、汽侧清洁程度%ESTIMATION OF WATER-AND STEAM-SIDE CLEANNESS IN CONDENSERS BY USING STANDARD HEAT TRANSFER COEFFICIENT

    Institute of Scientific and Technical Information of China (English)

    江宁; 曹祖庆

    2001-01-01

    The concept and physical meanings of condenser’s cleanness coefficient and the modified coefficient of air content in the steam side of condensers have been described,It is suggested to use the measured standard heat transfer coefficient in good state of condensers as a standard for comparison with heat transfer coefficient of condensers.The calculation method of standard heat transfer coefficient has been analyzed,a modified calculation method of test condition for water temperature and water volume etc.in the HEI formula is put forward,a method for on-line calculating the cleanness coefficient of the condenser and modified coefficient of air content at the steam side is put forward as well.%对凝汽器清洁系数和汽侧空气量修正系数的概念与物理意义进行了论述,提出了以良好状态实测标准传热系数作为凝汽器传热系数的比较标准,分析了标准传热系数的计算方法,提出了在HEI公式中对水温、水量等试验条件的修正算法,以及在线计算凝汽器清洁系数、汽侧空气量修正系数的方法。

  2. Environmental health in China: progress towards clean air and safe water.

    Science.gov (United States)

    Zhang, Junfeng; Mauzerall, Denise L; Zhu, Tong; Liang, Song; Ezzati, Majid; Remais, Justin V

    2010-03-27

    Environmental risk factors, especially air and water pollution, are a major source of morbidity and mortality in China. Biomass fuel and coal are burned for cooking and heating in almost all rural and many urban households, resulting in severe indoor air pollution that contributes greatly to the burden of disease. Many communities lack access to safe drinking water and sanitation, and thus the risk of waterborne disease in many regions is high. At the same time, China is rapidly industrialising with associated increases in energy use and industrial waste. Although economic growth from industrialisation has improved health and quality of life indicators, it has also increased the release of chemical toxins into the environment and the rate of environmental disasters, with severe effects on health. Air quality in China's cities is among the worst in the world, and industrial water pollution has become a widespread health hazard. Moreover, emissions of climate-warming greenhouse gases from energy use are rapidly increasing. Global climate change will inevitably intensify China's environmental health troubles, with potentially catastrophic outcomes from major shifts in temperature and precipitation. Facing the overlap of traditional, modern, and emerging environmental dilemmas, China has committed substantial resources to environmental improvement. The country has the opportunity to address its national environmental health challenges and to assume a central role in the international effort to improve the global environment.

  3. Emission projections for the U.S. Environmental Protection Agency Section 812 second prospective Clean Air Act cost/benefit analysis.

    Science.gov (United States)

    Wilson, James H; Mullen, Maureen A; Bollman, Andrew D; Thesing, Kirstin B; Salhotra, Manish; Divita, Frank; Neumann, James E; Price, Jason C; DeMocker, James

    2008-05-01

    Section 812 of the Clean Air Act Amendments (CAAA) of 1990 requires the U.S. Environmental Protection Agency (EPA) to perform periodic, comprehensive analyses of the total costs and total benefits of programs implemented pursuant to the CAAA. The first prospective analysis was completed in 1999. The second prospective analysis was initiated during 2005. The first step in the second prospective analysis was the development of base and projection year emission estimates that will be used to generate benefit estimates of CAAA programs. This paper describes the analysis, methods, and results of the recently completed emission projections. There are several unique features of this analysis. One is the use of consistent economic assumptions from the Department of Energy's Annual Energy Outlook 2005 (AEO 2005) projections as the basis for estimating 2010 and 2020 emissions for all sectors. Another is the analysis of the different emissions paths for both with and without CAAA scenarios. Other features of this analysis include being the first EPA analysis that uses the 2002 National Emission Inventory files as the basis for making 48-state emission projections, incorporating control factor files from the Regional Planning Organizations (RPOs) that had completed emission projections at the time the analysis was performed, and modeling the emission benefits of the expected adoption of measures to meet the 8-hr ozone National Ambient Air Quality Standards (NAAQS), the Clean Air Visibility Rule, and the PM2.5 NAAQS. This analysis shows that the 1990 CAAA have produced significant reductions in criteria pollutant emissions since 1990 and that these emission reductions are expected to continue through 2020. CAAA provisions have reduced volatile organic compound (VOC) emissions by approximately 7 million t/yr by 2000, and are estimated to produce associated VOC emission reductions of 16.7 million t by 2020. Total oxides of nitrogen (NO(x)) emission reductions attributable to the

  4. The role of integrated resource planning, environmental externalities, and anticipation of future regulation in compliance planning under the Clean Air Act Amendments of 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bernow, S.; Biewald, B.; Wulfsberg, K. [Tellus Institute, Boston, MA (United States)

    1993-07-01

    Utilities are developing sulfur dioxide (SO{sub 2}) emission compliance plans to meet limitations of the Clean Air Act Amendments of 1990 (CAAA). Compliance plans will have long-term effects on resource selection, fuel choice, and system dispatch. Use of integrated resource planning (IRP) is necessary to ensure compliance plans are consistent with the overall societal goals. In particular, environmental externalities must be integrated with the compliance planning process. The focus of the CAAA is on air pollution reduction, specifically acid gases and toxics, and attainment of National Ambient Air Quality Standards (NAAQS) for criteria pollutants. Title IV specifically focuses on sulfur dioxide with a national allowance trading system, while further regulation of toxics and nitrogen oxides is slated for additional study. Yet, compliance planning based narrowly upon today`s environmental regulations could fail to meet the broad goals of IRP if a larger array of environmental externalities is excluded from the analysis. Compliance planning must consider a broad range of environmental effects from energy production and use to (1) protect society`s long-term stake in environmental quality, and (2) ensure that today`s plans are rich enough to accommodate potential changes in regulation and national environmental goals. The explicit recognition of environmental effects, such as those associated with CO{sub 2} release, will result in prudent compliance plans that take advantage of current opportunities for pollution avoidance and have long-term viability in the face of regulatory change. By including such considerations, the mix of resources acquired and operated (supply and demand, existing and new, conventional and renewable, fuel type and fuel quality, pollution control, and dispatch protocols) will be robust and truly least-cost.

  5. Development of a software and hardware system for monitoring the air cleaning process using a cyclone-separator

    Science.gov (United States)

    Nicolaeva, B. K.; Borisov, A. P.; Zlochevskiy, V. L.

    2017-08-01

    The article is devoted to the development of a hardware-software complex for monitoring and controlling the process of air purification by means of a cyclone-separator. The hardware of this complex is the Arduino platform, to which are connected pressure sensors, air velocities, dustmeters, which allow monitoring of the main parameters of the cyclone-separator. Also, a frequency converter was developed to regulate the rotation speed of an asynchronous motor necessary to correct the flow rate, the control signals of which come with Arduino. The program part of the complex is written in the form of a web application in the programming language JavaScript and inserts into CSS and HTML for the user interface. This program allows you to receive data from sensors, build dependencies in real time and control the speed of rotation of an asynchronous electric drive. The conducted experiment shows that the cleaning efficiency is 95-99.9%, while the airflow at the cyclone inlet is 16-18 m/s, and at the exit 50-70 m/s.

  6. Validation of the criteria for initiating the cleaning of heating, ventilation, and air-conditioning (HVAC) ductwork under real conditions.

    Science.gov (United States)

    Lavoie, Jacques; Marchand, Geneviève; Cloutier, Yves; Lavoué, Jérôme

    2011-08-01

    Dust accumulation in the components of heating, ventilation, and air-conditioning (HVAC) systems is a potential source of contaminants. To date, very little information is available on recognized methods for assessing dust buildup in these systems. The few existing methods are either objective in nature, involving numerical values, or subjective in nature, based on experts' judgments. An earlier project aimed at assessing different methods of sampling dust in ducts was carried out in the laboratories of the Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST). This laboratory study showed that all the sampling methods were practicable, provided that a specific surface-dust cleaning initiation criterion was used for each method. However, these conclusions were reached on the basis of ideal conditions in a laboratory using a reference dust. The objective of this present study was to validate these laboratory results in the field. To this end, the laboratory sampling templates were replicated in real ducts and the three sampling methods (the IRSST method, the method of the U.S. organization National Air Duct Cleaner Association [NADCA] and that of the French organization Association pour la Prévention et l'Étude de la Contamination [ASPEC]) were used simultaneously in a statistically representative number of systems. The air return and supply ducts were also compared. Cleaning initiation criteria under real conditions were found to be 6.0 mg/100 cm(2) using the IRSST method, 2.0 mg/100 cm(2) using the NADCA method, and 23 mg/100 cm(2) using the ASPEC method. In the laboratory study, the criteria using the same methods were 6.0 for the IRSST method, 2.0 for the NADCA method, and 3.0 for the ASPEC method. The laboratory criteria for the IRSST and NADCA methods were therefore validated in the field. The ASPEC criterion was the only one to change. The ASPEC method therefore allows for the most accurate evaluation of dust accumulation in HVAC

  7. The Ontario Energy Board`s draft standard supply service code: effects on air quality

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J.; Bjorkquist, S. [Ontario Clean Air Alliance, Toronto, ON (Canada)

    1999-06-29

    The Ontario Clean Air Alliance (OCAA), a coalition of 67 organizations, takes issue with the Ontario Energy Board`s draft document `Standard Supply Service Code`, particularly sections 2.2.2. and 2.5.2 which they claim are not in the public interest unless the Ontario government implements the OCAA`s recommended emission caps. The alliance is of the view that without strict new environmental regulations the proposed Code would encourage the use of coal for electricity generation. Public health, the environment, consumer interests, job creation and promotion of a competitive electricity market would all be jeopardized by this development, the alliance states. The argument is supported by extensive reference to the Final Report of the Ontario Market Design Committee (MDC) which also emphasized the importance of combining the introduction of competition with appropriate environmental regulations, singling out the emission cap and trade program, and recommending that it be launched concurrently with the electricity market opening for competition. The view of the MDC was that public support for restructuring would not be forthcoming in the absence of regulatory measures to control power plant emissions. 25 refs.

  8. 40 CFR 62.14830 - Does this subpart require me to obtain an operating permit under title V of the Clean Air Act?

    Science.gov (United States)

    2010-07-01

    ... operating permit unless you meet the relevant requirements specified in 40 CFR 62.14525(a) through (h) and (j) through (o) and all of the requirements specified in 40 CFR 62.14531. ... an operating permit under title V of the Clean Air Act? 62.14830 Section 62.14830 Protection...

  9. A historical overview of the development of manganese (Mn) pharmacokinetic data under Section 211(b) of the Clean Air Act (CAA)

    Science.gov (United States)

    Abstract for Manganese 2016A historical overview of the development of manganese (Mn) pharmacokinetic data under Section 211(b) of the Clean Air Act (CAA)William K BoyesBackground. In the 1990’s, the use of methylcyclopentadienyl manganese tricarbonyl (MMT) as an octane-enh...

  10. 40 CFR Appendix H to Subpart A of... - Clean Air Act Amendments of 1990 Phaseout Schedule for Production of Ozone-Depleting Substances

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Clean Air Act Amendments of 1990 Phaseout Schedule for Production of Ozone-Depleting Substances H Appendix H to Subpart A of Part 82... STRATOSPHERIC OZONE Production and Consumption Controls Pt. 82, Subpt. A, App. H Appendix H to Subpart A of...

  11. A historical overview of the development of manganese (Mn) pharmacokinetic data under Section 211(b) of the Clean Air Act (CAA)

    Science.gov (United States)

    Abstract for Manganese 2016A historical overview of the development of manganese (Mn) pharmacokinetic data under Section 211(b) of the Clean Air Act (CAA)William K BoyesBackground. In the 1990’s, the use of methylcyclopentadienyl manganese tricarbonyl (MMT) as an octane-enh...

  12. Issuance of the Clean Air Act Stationary Source Compliance Monitoring Strategy

    Science.gov (United States)

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  13. Response to Request for EPA's Interpretation of Several Provisions of the Clean Air Act

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  14. Guidance On Enforcement of PSD Requirements Under the Clean Air Act

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  15. Issuance of PSD Permit to Sources Impacting Dirty and Clean Air Areas

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  16. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions, Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Ecological and Environmental Monitoring

    2011-06-30

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada National Security Site (NNSS, formerly the Nevada Test Site) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as those from the damaged Fukushima nuclear power plant in Japan. Because this report is intended to discuss radioactive air emissions during calendar year 2010, data on radionuclides in air from the 2011 Fukushima nuclear power plant releases are not presented but will be included in the report for calendar year 2011. The NNSS demonstrates compliance with the NESHAP

  17. 78 FR 51186 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-08-20

    ..., Environmental Integrity Project, Louisiana Bucket Brigade, and Texas Environmental Justice Advocacy Services... complaint concerning EPA's obligation to develop residual risk and technology standards for the petroleum... 112(f)(2), 42 U.S.C. 7412(f)(2), for petroleum refineries under 40 CFR Part 63, Subpart CC and 40 CFR...

  18. 78 FR 56633 - Approval and Promulgation of Air Quality Implementation Plans; New York; Determination of Clean...

    Science.gov (United States)

    2013-09-13

    ... of attainment of the PM 10 standard in Coso Junction, California), and 75 FR 6571 (February 10, 2010..., California area); 72 FR 14422 (March 28, 2007) (Miami, Arizona area); 75 FR 27944 (May 19, 2010) (Coso... and 75 FR 27944, the proposed and final determination of attainment for Coso Junction. \\6\\ Thus,...

  19. 78 FR 26103 - Proposed Standard Operating Procedure (SOP) of the Aircraft Certification Service (AIR) Project...

    Science.gov (United States)

    2013-05-03

    ... Federal Aviation Administration Proposed Standard Operating Procedure (SOP) of the Aircraft Certification... comments on, the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the... comments on the SOP to: Federal Aviation Administration (FAA) Aircraft Certification Service,...

  20. Photocatalytic equipment with nitrogen-doped titanium dioxide for air cleaning and disinfecting

    Science.gov (United States)

    Son Le, Thanh; Buu Ngo, Quoc; Dung Nguyen, Viet; Chau Nguyen, Hoai; Hien Dao, Trong; Tin Tran, Xuan; Kabachkov, E. N.; Balikhin, I. L.

    2014-03-01

    Nitrogen-doped TiO2 nanoparticle photocatalysts were synthesized by a sol-gel procedure using tetra-n-butyl orthotitanate as a titanium precursor and urea as a nitrogen source. Systematic studies for the preparation parameters and their impact on the material's structure were carried out by multiple techniques: thermogravimetric and differential scanning calorimetric analysis, x-ray diffraction, scanning electron microscope, transmission electron microscopy, energy dispersive x-ray spectroscopy and UV-Vis diffuse reflectance spectrophotometry showed that the nitrogen-doped TiO2 calcined at 500 °C for 3 h exhibited a spherical form with a particle size about 15-20 nm and crystal phase presented a mixture of 89.12% anatase. The obtained product was deposited on a porous quartz tube (D = 74 mm l = 418 mm) to manufacture an air photocatalytic cleaner as a prototype of the TIOKRAFT company's equipment. The created air cleaner was able to remove 60% of 10 ppm acetone within 390 min and degrade 98.5% of bacteria (total aerobic bacteria and fungi, 300 cfu m-3) within 120 min in a 10 m3 box. These photodegradation activities of N-TiO2 are higher than that of the commercial nano-TiO2 (Skyspring Inc., USA, particle size of 5-10 nm).

  1. Air cleaning performance of a new environmentally controlled primary crusher operator booth.

    Science.gov (United States)

    Organiscak, J A; Cecala, A B; Zimmer, J A; Holen, B; Baregi, J R

    2016-02-01

    The National Institute for Occupational Safety and Health (NIOSH) cooperated with 3M Company in the design and testing of a new environmentally controlled primary crusher operator booth at the company's Wausau granite quarry near Wausau, WI. This quarry had an older crusher booth without a central heating, ventilation and air conditioning (HVAC) system, and without an air filtration and pressurization system. A new replacement operator booth was designed and installed by 3M based on design considerations from past NIOSH research on enclosed cab filtration systems. NIOSH conducted pre-testing of the old booth and post-testing of the new booth to assess the new filtration and pressurization system's effectiveness in controlling airborne dusts and particulates. The booth's dust and particulate control effectiveness is described by its protection factor, expressed as a ratio of the outside to inside concentrations measured during testing. Results indicate that the old booth provided negligible airborne respirable dust protection and low particulate protection from the outside environment. The newly installed booth provided average respirable dust protection factors from 2 to 25 over five shifts of dust sampling with occasional worker ingress and egress from the booth, allowing some unfiltered contaminants to enter the enclosure. Shorter-term particle count testing outside and inside the booth under near-steady-state conditions, with no workers entering or exiting the booth, resulted in protection factors from 35 to 127 on 0.3- to 1.0-μm respirable size particulates under various HVAC airflow operating conditions.

  2. Clean Cities ozone air quality attainment and maintenance strategies that employ alternative fuel vehicles, with special emphasis on natural gas and propane

    Energy Technology Data Exchange (ETDEWEB)

    Santini, D.J.; Saricks, C.L.

    1998-08-04

    Air quality administrators across the nation are coming under greater pressure to find new strategies for further reducing automotive generated non-methane hydrocarbon (NMHC) and nitrogen oxide (NOx) emissions. The US Environmental Protection Agency (EPA) has established stringent emission reduction requirements for ozone non-attainment areas that have driven the vehicle industry to engineer vehicles meeting dramatically tightened standards. This paper describes an interim method for including alternative-fueled vehicles (AFVs) in the mix of strategies to achieve local and regional improvements in ozone air quality. This method could be used until EPA can develop the Mobile series of emissions estimation models to include AFVs and until such time that detailed work on AFV emissions totals by air quality planners and emissions inventory builders is warranted. The paper first describes the challenges confronting almost every effort to include AFVs in targeted emissions reduction programs, but points out that within these challenges resides an opportunity. Next, it discusses some basic relationships in the formation of ambient ozone from precursor emissions. It then describes several of the salient provisions of EPA`s new voluntary emissions initiative, which is called the Voluntary Mobile Source Emissions Reduction Program (VMEP). Recent emissions test data comparing gaseous-fuel light-duty AFVs with their gasoline-fueled counterparts is examined to estimate percent emissions reductions achievable with CNG and LPG vehicles. Examples of calculated MOBILE5b emission rates that would be used for summer ozone season planning purposes by an individual Air Quality Control Region (AQCR) are provided. A method is suggested for employing these data to compute appropriate voluntary emission reduction credits where such (lighter) AFVs would be acquired. It also points out, but does not quantify, the substantial reduction credits potentially achievable by substituting gaseous

  3. Determination of the Clean Air Delivery Rate (CADR) of Photocatalytic Oxidation (PCO) Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part I: Theoretical Considerations.

    Science.gov (United States)

    Dumont, Éric; Héquet, Valérie

    2017-03-06

    This study demonstrated that a laboratory-scale recirculation closed-loop reactor can be an efficient technique for the determination of the Clean Air Delivery Rate (CADR) of PhotoCatalytic Oxidation (PCO) air purification devices. The recirculation closed-loop reactor was modeled by associating equations related to two ideal reactors: one is a perfectly mixed reservoir and the other is a plug flow system corresponding to the PCO device itself. Based on the assumption that the ratio between the residence time in the PCO device and the residence time in the reservoir τP/τR tends to 0, the model highlights that a lab closed-loop reactor can be a suitable technique for the determination of the efficiency of PCO devices. Moreover, if the single-pass removal efficiency is lower than 5% of the treated flow rate, the decrease in the pollutant concentration over time can be characterized by a first-order decay model in which the time constant is proportional to the CADR. The limits of the model are examined and reported in terms of operating conditions (experiment duration, ratio of residence times, and flow rate ranges).

  4. Clean air. Measures against fine dust and nitrogen oxide; Luftreinhalteplanung. Massnahmen gegen Feinstaub und Stickstoffoxide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-10-15

    Within the meeting of the Bavarian State Ministry of the Environment (Hof, Federal Republic of Germany) on 23rd October, 2012, the following lectures were held: (1) Future development of emissions and immission in Germany (Johanna Appelhans); (2) Air pollution control in urban areas - Example Stuttgart (Ulrich Reuter); (3) Green zones in Munich and Augsburg - Results from the efficiency analysis 2012 (Manfred Ertl); (4) Photocatalytic efficiency of titanium dioxide - Pilot experiment Fulda (Marita Mang); (5) Emission behaviour of Euro V/5 and VI/6 vehicles in real operation (Stefan Hausberger); (6) Reduction of particles and NO{sub x} by means of Euro VI commercial vehicles (Stefan Kamm); (7) Possibilities of retrofitting at vehicles for the reduction of emissions of fine dust and nitrous oxides (Michael Himmen); (8) Measures for reduction of emissions at construction machinery (Hinrich Helms); (9) ChimCat/circledR - Catalytic reduction of emissions (Martin Pley); (10) Improvement of the immission behaviour at the Airport Munich (Hermann Blomeyer).

  5. Combining active chilled beams and air-cleaning technologies to improve the indoor climate in offices

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2013-01-01

    of air in offices. For this purpose, a mechanical filter with low pressure drop was selected for testing in a laboratory environment. The measurements included tests of the filter in a ductwork to study the efficiency of the filter. Moreover, the combined system of the filter and a chilled beam...... was tested in a room. The efficiency of the mechanical filter to remove ultrafine particles was examined using pure wax candles and salt as sources of emission of particles. The measurements in the duct showed that the efficiency of the filter ranged between 54% and 78% and that the pressure loss was less...... than 5 Pa (0.104 Ibf /ft2). Furthermore, the measurement results of the combined system showed that adding the filter accelerated the removal rate of the particles by 2 h-1. However, the efficiency of the chilled beam in exchanging heat was reduced by 38%....

  6. 40 CFR 63.322 - Standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards. 63.322 Section 63.322... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities § 63.322 Standards. (a) The owner or operator of...

  7. Nevada Test Site National Emission Standards for Hazardous Air Pollutants Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Robert Grossman; Ronald Warren

    2008-06-01

    The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office. From 1951 through 1992, the NTS was operated as the nation's site for nuclear weapons testing. The release of man-made radionuclides from the NTS as a result of testing activities has been monitored since the first decade of atmospheric testing. After 1962, when nuclear tests were conducted only underground, the radiation exposure to the public surrounding the NTS was greatly reduced. After the 1992 moratorium on nuclear testing, radiation monitoring on the NTS focused on detecting airborne radionuclides which come from historically contaminated soils resuspended into the air (e.g., by winds) and tritium-contaminated soil moisture emitted to the air from soils through evapotranspiration. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility (e.g., the NTS) to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This is the dose limit established for someone living off of the NTS from radionuclides emitted to air from the NTS. This limit does not include the radiation doses that members of the public may receive through the intake of radioactive particles unrelated to NTS activities, such as those that come from naturally occurring elements in the environment (e.g., naturally occurring radionuclides in soil or radon gas from the earth or natural building materials), or from other man-made sources (e.g., medical treatments). The NTS demonstrates compliance using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the

  8. 77 FR 12482 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Direct final rule... Clean Air Act (CAA). This submittal incorporates the National Ambient Air Quality Standards (NAAQS) for...

  9. 75 FR 15620 - Federal Motor Vehicle Safety Standards; Air Brake Systems

    Science.gov (United States)

    2010-03-30

    ... National Highway Traffic Safety Administration 49 CFR Part 571 RIN 2127-AK62 Federal Motor Vehicle Safety... that amended the Federal motor vehicle safety standard for air brake systems by requiring substantial... 37122) amending Federal Motor Vehicle Safety Standard (FMVSS) No. 121, Air Brake Systems, to...

  10. 75 FR 32005 - National Emission Standards for Hazardous Air Pollutants for Major Sources: Industrial...

    Science.gov (United States)

    2010-06-04

    ... hazardous air pollutants emissions standards reflecting the application of the maximum achievable control....7485 of subpart DDDDD (National Emission Standards for Hazardous Air Pollutants (NESHAP) for Industrial... were not achieving emissions reductions through the use of an emission control system and there were...

  11. Influence of regional development policies and clean technology adoption on future air pollution exposure

    Science.gov (United States)

    Hixson, Mark; Mahmud, Abdullah; Hu, Jianlin; Bai, Song; Niemeier, Debbie A.; Handy, Susan L.; Gao, Shengyi; Lund, Jay R.; Sullivan, Dana Coe; Kleeman, Michael J.

    2010-02-01

    Future air pollution emissions in the year 2030 were estimated for the San Joaquin Valley (SJV) in central California using a combined system of land use, mobile, off-road, stationary, area, and biogenic emissions models. Four scenarios were developed that use different assumptions about the density of development and level of investment in transportation infrastructure to accommodate the expected doubling of the SJV population in the next 20 years. Scenario 1 reflects current land-use patterns and infrastructure while scenario 2 encouraged compact urban footprints including redevelopment of existing urban centers and investments in transit. Scenario 3 allowed sprawling development in the SJV with reduced population density in existing urban centers and construction of all planned freeways. Scenario 4 followed currently adopted land use and transportation plans for the SJV. The air quality resulting from these urban development scenarios was evaluated using meteorology from a winter stagnation event that occurred on December 15th, 2000 to January 7th 2001. Predicted base-case PM2.5 mass concentrations within the region exceeded 35 μg m -3 over the 22-day episode. Compact growth reduced the PM2.5 concentrations by ˜1 μg m -3 relative to the base-case over most of the SJV with the exception of increases (˜1 μg m -3) in urban centers driven by increased concentrations of elemental carbon (EC) and organic carbon (OC). Low-density development increased the PM2.5 concentrations by 1-4 μg m -3 over most of the region, with decreases (0.5-2 μg m -3) around urban areas. Population-weighted average PM2.5 concentrations were very similar for all development scenarios ranging between 16 and 17.4 μg m -3. Exposure to primary PM components such as EC and OC increased 10-15% for high density development scenarios and decreased by 11-19% for low-density scenarios. Patterns for secondary PM components such as nitrate and ammonium ion were almost exactly reversed, with a 10

  12. Parametric Evaluation of an Innovative Ultra-Violet PhotocatalyticOxidation (UVPCO) Air Cleaning Technology for Indoor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, Alfred T.; Sullivan, Douglas P.; Fisk, William J.

    2005-10-31

    An innovative Ultra-Violet Photocatalytic Oxidation (UVPCO) air cleaning technology employing a semitransparent catalyst coated on a semitransparent polymer substrate was evaluated to determine its effectiveness for treating mixtures of volatile organic compounds (VOCs) representative of indoor environments at low, indoor-relevant concentration levels. The experimental UVPCO contained four 30 by 30-cm honeycomb monoliths irradiated with nine UVA lamps arranged in three banks. A parametric evaluation of the effects of monolith thickness, air flow rate through the device, UV power, and reactant concentrations in inlet air was conducted for the purpose of suggesting design improvements. The UVPCO was challenged with three mixtures of VOCs. A synthetic office mixture contained 27 VOCs commonly measured in office buildings. A building product mixture was created by combining sources including painted wallboard, composite wood products, carpet systems, and vinyl flooring. The third mixture contained formaldehyde and acetaldehyde. Steady state concentrations were produced in a classroom laboratory or a 20-m{sup 3} chamber. Air was drawn through the UVPCO, and single-pass conversion efficiencies were measured from replicate samples collected upstream and downstream of the reactor. Thirteen experiments were conducted in total. In this UVPCO employing a semitransparent monolith design, an increase in monolith thickness is expected to result in general increases in both reaction efficiencies and absolute reaction rates for VOCs oxidized by photocatalysis. The thickness of individual monolith panels was varied between 1.2 and 5 cm (5 to 20 cm total thickness) in experiments with the office mixture. VOC reaction efficiencies and rates increased with monolith thickness. However, the analysis of the relationship was confounded by high reaction efficiencies in all configurations for a number of compounds. These reaction efficiencies approached or exceeded 90% for alcohols, glycol

  13. Clean air plans and action plans: perspectives from the viewpoint of environmental and public health; Luftreinhalteplaene und Aktionsplaene - eine Bewertung aus umweltmedizinischer Sicht

    Energy Technology Data Exchange (ETDEWEB)

    Eikmann, T.; Herr, C. [Inst. fuer Hygiene und Umweltmedizin, Universitaetsklinikum Giessen und Marburg, Justus-Liebig-Univ. Giessen, Giessen (Germany); [Technische Univ. Dreden, Pirna (Germany). Inst. fuer Abfallwirtschaft und Altlasten; Koeckler, H. [Center for Environmental Systems Research (CESR), Univ. Kassel (Germany); [Mentec GmbH, Aue/Sa. (Germany); Nieden, A. zur [Inst. fuer Hygiene und Umweltmedizin, Universitaetsklinikum Giessen und Marburg, Justus-Liebig-Univ. Giessen, Giessen (Germany); FG Stadtklimatologie, Univ. Kassel (Germany); Katzschner, L. [FG Stadtklimatologie, Univ. Kassel (Germany); [INTECUS Dresden GmbH (Germany); Schimmelpfennig, M. [Gesundheitsamt der Stadt Kassel (Germany); Eikmann, S. [GUK - Gesellschaft fuer Umwelttoxikologie und Krankenhaushygiene mbH, Wetzlar (Germany)

    2005-07-01

    The present discussion on the health effects associated with airborne fine particulate matter has lead to an increased public interest in the general framework of compilation and evaluation of clean air plans and actions plans. While the surveys of the ''old'' clean air plans of the 80ies and 90ies of the last century relied on assessment of direct and indirect effects of air pollution on human health (and ecology), theses surveys are not part of the ''new'' clean air plans according to European law. This reduction of surveys and actions directed at threshold compliance only, abandons assessing, i.e., documentation and evaluation the health status and quality of life of populations. Assessment of individual and focus group specific sensibility and vulnerability becomes possible once health related, sociodemographic and environmental data are combined. By this, unequal life chance, i.e., unimpaired health as well as reasonable strategies towards minimizing environmental injustice can be identified. As of yet it is unclear, to what extend quality of life and quality of environment of populations living in air polluted areas are attributable to socioeconomic factors. Likewise, it is not known to which degree the environmental quality of individuals and families is self determined. This has to be considered especially for children, immigrants and women. These issues i.e., environmental justice/injustice should be considered in future projects on the development of clean air plans and especially actions plans derived thereof. Scientists, government officials and physicians working in field of preventive or environmental medicine cannot agree to a limitation of the cautionary principle to the bare compliance with thresholds. (orig.)

  14. Emerging developments in the standardized chemical characterization of indoor air quality.

    Science.gov (United States)

    Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi

    2017-01-01

    Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non

  15. Proceedings of the Clean Air Foundation's shifting mobility workshop

    Energy Technology Data Exchange (ETDEWEB)

    Serafini, E. [Clean Air Foundation, Toronto, ON (Canada)

    2004-07-01

    This workshop brought together organizations with transportation-related initiatives underway across Ontario. The objective of the workshop was to identify strategic options for developing and implementing effective transportation-related public education and outreach initiatives, as well as to identify barriers and opportunities for public participation in sustainable transportation programs and create opportunities for collaboration to maximize the efficiency of existing initiatives. Attendees included representatives from federal, provincial, municipal and regional governments, non-government organizations and the private sector from across Ontario. Three themes were identified: (1) activities focused on encouraging the shift from traveling in single occupant vehicles to transit, autosharing, trains, bicycles and carpooling, (2) activities focused on encouraging consumers to choose more fuel efficient and lower emission vehicles and fuels, and (3) activities focused on encouraging the motoring public to change habits that will increase fuel efficiency and lower emissions, such as not idling their vehicle and monitoring tire pressure. Keynote and panel presentations showcased existing collaborative sustainable transportation initiatives, including integrated transportation systems in Germany. In addition, a summary of outcomes from Pollution Probe's Transportation, Air Issues and Human Health conference was presented in order to provide strategic options for the future and to highlight barriers and opportunities. Strategy sessions were held to allow participants the opportunity to identify specific areas of collaboration. The Smart Commute Initiative was discussed. Emerging automobile technologies were discussed by the Canadian Vehicle Manufacturer's Association. Issues concerning educational programs in schools and in the workplace were examined, as well as the challenges of achieving a system of integrated and sustainable urban transportation. tabs

  16. 75 FR 72963 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile...

    Science.gov (United States)

    2010-11-29

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile Organic Compound Emissions From Industrial Solvent Cleaning Operations; Withdrawal of Direct Final... standards for industrial solvent cleaning operations that satisfy the reasonably available...

  17. Environmental compliance guide. Guidance manual for Department of Energy compliance with the Clean Air Act: nonattainment areas

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-09-01

    The purpose of this manual is to identify information requirements associated with air quality permit applications in areas for which ambient pollutant levels currently exceed the national ambient air quality standards (nonattainment areas). The manual is to be used by project managers at the US Department of Energy (DOE), in conjunction with the DOE Environmental Compliance Guide, to provide preliminary estimates of information required to obtain air quality permits for DOE projects. An analysis of nonattainment area permitting found that permitting of all sources in such areas is done on the state or local levels; the Environmental Protection Agency does not grant permits in nonattainment areas. As a result, Federal information requirements for permitting in nonattainment areas are somewhat vague. To provide a more realistic picture of nonattainment area permitting, selected state and local regulations were surveyed, and were found to contain more detail on the information required for permit approval. The most potentially demanding information requirements associated with nonattainment area permitting are the determination of Lowest Achievable Emission Rate, the negotiation of external emission offsets, and the consideration of the environmental impacts of project alternatives in ozone and carbon monoxide nonattainment areas. In any state, a few information requirements for nonattainment area permitting are likely to overlap with information requirements of other permitting processes, such as those in the Prevention of Significant Deterioration procedure. These requirements are emissions data and air quality modeling and its associated input data requirements (meteorology, topography, etc.).

  18. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions, Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Ecological and Environmental Monitoring

    2012-06-19

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as the damaged Fukushima nuclear power plant in Japan. Radionuclides from the Fukushima nuclear power plant were detected at the NNSS in March 2011 and are discussed further in Section III. The NNSS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the EPA for use on the

  19. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2012

    Energy Technology Data Exchange (ETDEWEB)

    Warren, R.

    2013-06-10

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as the damaged Fukushima nuclear power plant in Japan in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA for use on the NNSS in 2001 (EPA 2001a) and has

  20. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2013

    Energy Technology Data Exchange (ETDEWEB)

    Warren, R.

    2014-06-04

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitations to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as the damaged Fukushima nuclear power plant in Japan in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA for use on the NNSS in 2001 (EPA 2001a) and has

  1. 76 FR 76972 - Release of Final Integrated Review Plan for the National Ambient Air Quality Standards for Lead

    Science.gov (United States)

    2011-12-09

    ... AGENCY Release of Final Integrated Review Plan for the National Ambient Air Quality Standards for Lead... the National Ambient Air Quality Standards for Lead. This document contains the plans for the review of the air quality criteria and national ambient air quality standards (NAAQS) for lead (Pb). The...

  2. 76 FR 20347 - Release of Draft Integrated Review Plan for the National Ambient Air Quality Standards for Lead

    Science.gov (United States)

    2011-04-12

    ... AGENCY Release of Draft Integrated Review Plan for the National Ambient Air Quality Standards for Lead... National Ambient Air Quality Standards for Lead (draft IRP). This document contains the plans for the review of the air quality criteria and national ambient air quality standards (NAAQS) for lead (Pb)....

  3. 40 CFR 50.7 - National primary and secondary ambient air quality standards for PM2.5.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for PM2.5. 50.7 Section 50.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.7 National primary and secondary ambient air quality standards for PM2.5. (a) The national primary...

  4. 40 CFR 50.13 - National primary and secondary ambient air quality standards for PM2.5.

    Science.gov (United States)

    2010-07-01

    ... air quality standards for PM2.5. 50.13 Section 50.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.13 National primary and secondary ambient air quality standards for PM2.5. (a) The national...

  5. 40 CFR 50.10 - National 8-hour primary and secondary ambient air quality standards for ozone.

    Science.gov (United States)

    2010-07-01

    ... ambient air quality standards for ozone. 50.10 Section 50.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.10 National 8-hour primary and secondary ambient air quality standards for ozone. (a) The level...

  6. 40 CFR 50.9 - National 1-hour primary and secondary ambient air quality standards for ozone.

    Science.gov (United States)

    2010-07-01

    ... ambient air quality standards for ozone. 50.9 Section 50.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.9 National 1-hour primary and secondary ambient air quality standards for ozone. (a) The level...

  7. Economic effects of clean indoor air policies on bar and restaurant employment in Minneapolis and St Paul, Minnesota.

    Science.gov (United States)

    Klein, Elizabeth G; Forster, Jean L; Erickson, Darin J; Lytle, Leslie A; Schillo, Barbara

    2010-01-01

    Clean indoor air (CIA) policies have been adopted by communities across the United States and internationally to protect employees in all workplaces from exposure to environmental tobacco smoke. Concerns have been raised that banning smoking in workplaces, particularly in bars and restaurants, will result in severe, negative economic effects. Although objective studies have consistently found no significant economic effects from CIA policies, the concerns persist that CIA policies will negatively affect hospitality businesses. Employment in bars and restaurants in Minneapolis and St Paul, Minnesota, was independently evaluated over a five-year period during which CIA policies were established in each city. An interrupted time series analysis was used to evaluate the short-, intermediate, and longer-term economic effects of the local CIA policies, accounting for the rest of the hospitality industry. The CIA policies were associated with an increase of three percent to four percent in employment for restaurants in Minneapolis and St Paul, after accounting for the rest of the hospitality industry. The CIA policies were inconsistent in their association with bar employment. A comprehensive CIA policy in Minneapolis was associated with an increase of five percent to six percent in bar employment, and St Paul had a one percent nonsignificant decrease in bar employment. The CIA policies continue to yield the best protection against workplace exposure to environmental tobacco smoke for bars and restaurant employees and were not associated with large employment changes for the short or longer term in two urban Midwestern cities in the United States.

  8. Air pollution-related health and climate benefits of clean cookstove programs in Mozambique

    Science.gov (United States)

    Anenberg, Susan C.; Henze, Daven K.; Lacey, Forrest; Irfan, Ans; Kinney, Patrick; Kleiman, Gary; Pillarisetti, Ajay

    2017-02-01

    Approximately 95% of households in Mozambique burn solid fuels for cooking, contributing to elevated indoor and outdoor fine particulate matter (PM2.5) concentrations and subsequent health and climate impacts. Little is known about the potential health and climate benefits of various approaches for expanding the use of cleaner stoves and fuels in Mozambique. We use state-of-the-science methods to provide a first-order estimation of potential air pollution-related health and climate benefits of four illustrative scenarios in which traditional cooking fires and stoves are displaced by cleaner and more efficient technologies. For rural areas, we find that a 10% increase in the number of households using forced draft wood-burning stoves could achieve >2.5 times more health benefits from reduced PM2.5 exposure (200 avoided premature deaths and 14 000 avoided disability adjusted life years, DALYs, over a three-year project lifetime) compared to natural draft stoves in the same households, assuming 70% of households use the new technology for both cases. Expanding use of LPG stoves to 10% of households in five major cities is estimated to avoid 160 premature deaths and 11 000 DALYs from reduced PM2.5 exposure for a three-year intervention, assuming 60% of households use the new stove. Advanced charcoal stoves would achieve ∽80% of the PM2.5-related health benefits of LPG stoves. Approximately 2%–5% additional health benefits would result from reduced ambient PM2.5, depending on the scenario. Although climate impacts are uncertain, we estimate that all scenarios would reduce expected climate change-related temperature increases from continued solid fuel use by 4%–6% over the next century. All results are based on an assumed adjustment factor of 0.8 to convert from laboratory-based emission reduction measurements to exposure reductions, which could be optimistic in reality given potential for continued use of the traditional stove. We conclude that cleaner cooking

  9. US-China Clean Energy Research Center on Building Energy Efficiency: Materials that Improve the Cost-Effectiveness of Air Barrier Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-12-01

    The US–China Clean Energy Research Center (CERC) was launched in 2009 by US Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. This 5-year collaboration emerged from the fact that the United States and China are the world’s largest energy producers, energy consumers, and greenhouse gas emitters, and that their joint effort could have significant positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-related research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE). The project discussed in this report was part of the CERC-BEE consortia; its objective was to lower energy use in buildings by developing and evaluating technologies that improve the cost-effectiveness of air barrier systems for building envelopes.

  10. Development of standardized air-blown coal gasifier/gas turbine concepts for future electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Blough, E.; Russell, W.; Leach, J.W.

    1990-08-01

    Computer models have been developed for evaluating conceptual designs of integrated coal gasification combined cycle power plants. An overall system model was developed for performing thermodynamic cycle analyses, and detailed models were developed for predicting performance characteristics of fixed bed coal gasifiers and hot gas clean up subsystem components. The overall system model performs mass and energy balances and does chemical equilibrium analyses to determine the effects of changes in operating conditions, or to evaluate proposed design changes. An existing plug flow model for fixed bed gasifiers known as the Wen II model was revised and updated. Also, a spread sheet model of zinc ferrite sulfur sorbent regeneration subsystem was developed. Parametric analyses were performed to determine how performance depends on variables in the system design. The work was done to support CRS Sirrine Incorporated in their study of standardized air blown coal gasifier gas turbine concepts.

  11. Nevada Test Site National Emission Standards for Hazardous Air Pollutants Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Warren and Robert F. Grossman

    2009-06-30

    The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office. From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to under-ground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by winds) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the North Las Vegas Facility (NLVF), an NTS support complex in the city of North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2008a) limits the release of radioactivity from a U.S. Department of Energy facility (e.g., the NTS) to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from other man-made sources such as medical treatments. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo

  12. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Ciucci, John [National Security Technologies, LLC, Las Vegas, NV (United States)

    2010-06-11

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no

  13. National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Ecological and Environmental Monitoring

    2010-06-11

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no

  14. 蔬菜清洗中气流强化作用研究%Effects of Vegetable Cleaning Strengthened by Air Fl ow

    Institute of Scientific and Technical Information of China (English)

    李云飞; 张青; 钱丽丽; 李方正

    2001-01-01

    The cleaning mechanisms of vegetable strengthened by air flo w were discussed in the paper. The flow field of cleaning water and the motion s tate of vegetables disturbed by air flow were primarily investigated. The result s s howed that the level of cleaning water was increased approximately 0.03 m due to plenty of gas bubbles near the free surface of water. The cleaning effects of v egetable were strengthened by entrainment of air free-jet and cavitation. Compa red those with non-immersed, the cleaning time for potatoes and greens pre-imm ersed in cool water for 10min, 30 min were also presented.%论述了蔬菜清洗中气流对强化洗净率的作用机理,初步实验研究气流对 洗涤水和蔬菜的扰动状况以及清洗效果。结果表明,在本试验条件下,大量空泡集聚在洗涤 水上部并使清 洗槽液面膨胀0.03 m,射流的卷吸和空泡溃灭强化了对蔬菜的冲刷效果,并给出了马铃薯和 小青菜在未浸泡和分别浸泡10 min、30 min后的洗净时间。

  15. Heating, Air-Conditioning, and Refrigeration Technician. National Skill Standards.

    Science.gov (United States)

    Vocational Technical Education Consortium of States, Decatur, GA.

    This guide contains information on the knowledge and skills identified by industry as essential to the job performance of heating, air-conditioning, and refrigeration technicians. It is intended to assist training providers in public and private institutions, as well as in industry, to develop and implement training that will provide workers with…

  16. Effect of Water Cleaning on Performance of Air Filtration Medias%水清洗对空气净化材料过滤性能的影响

    Institute of Scientific and Technical Information of China (English)

    刘晓培; 卞思思; 常德强; 毛宁; 柳静献; 孙熙

    2012-01-01

    Air filtration media are designed for disposable, but in some application, it should be used for many times with water cleaning. Through experiments, the performances of polyester fiber layer media, which are cleaned with water for many times, including filtration elfieieney, resistance, dust capacity are studied in the paper. It was indicated by the results that water cleaning has less effect on filtration et/ieieney, resistance and dust capacity of the filter media. Therefore, air filtration media can be used repeatedly by way of water cleaning.%用于空气净化的材料一般为一次性使用,但有的应用场所需要对其进行反复水清洗多次使用。通过实验手段,研究常规涤纶纤维层滤料,在荷尘、清洗、烘干、荷尘等多次反复中其过滤效率、阻力、容尘量的变化情况。实验结果表明,清洗对滤料的过滤效率、阻力和容尘量没有明显的影响,滤料可以通过水清洗的方式反复使用。

  17. 77 FR 46371 - National Emission Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing...

    Science.gov (United States)

    2012-08-03

    ... the Portland Cement Manufacturing Industry and Standards of Performance for Portland Cement Plants... Standards for Hazardous Air Pollutants for the Portland Cement Manufacturing Industry and Standards of Performance for Portland Cement Plants,'' which was published in the Federal Register on July 18, 2012....

  18. 76 FR 54528 - Standard Operating Procedures (SOP) of the Aircraft Certification Service (AIR) Process for the...

    Science.gov (United States)

    2011-09-01

    ... Federal Aviation Administration Standard Operating Procedures (SOP) of the Aircraft Certification Service...) standard operating procedure (SOP) describing the process used to sequence certification projects that are... before October 3, 2011. ADDRESSES: Send all comments on the SOP : AIR-100-001; Standard...

  19. 78 FR 6673 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Science.gov (United States)

    2013-01-30

    ... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines; Final Rule #0;#0;Federal Register / Vol. 78, No. 20... Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines...

  20. Elemental analyses of goundwater: demonstrated advantage of low-flow sampling and trace-metal clean techniques over standard techniques

    Science.gov (United States)

    Creasey, C. L.; Flegal, A. R.

    The combined use of both (1) low-flow purging and sampling and (2) trace-metal clean techniques provides more representative measurements of trace-element concentrations in groundwater than results derived with standard techniques. The use of low-flow purging and sampling provides relatively undisturbed groundwater samples that are more representative of in situ conditions, and the use of trace-element clean techniques limits the inadvertent introduction of contaminants during sampling, storage, and analysis. When these techniques are applied, resultant trace-element concentrations are likely to be markedly lower than results based on standard sampling techniques. In a comparison of data derived from contaminated and control groundwater wells at a site in California, USA, trace-element concentrations from this study were 2-1000 times lower than those determined by the conventional techniques used in sampling of the same wells prior to (5months) and subsequent to (1month) the collections for this study. Specifically, the cadmium and chromium concentrations derived using standard sampling techniques exceed the California Maximum Contaminant Levels (MCL), whereas in this investigation concentrations of both of those elements are substantially below their MCLs. Consequently, the combined use of low-flow and trace-metal clean techniques may preclude erroneous reports of trace-element contamination in groundwater. Résumé L'utilisation simultanée de la purge et de l'échantillonnage à faible débit et des techniques sans traces de métaux permet d'obtenir des mesures de concentrations en éléments en traces dans les eaux souterraines plus représentatives que les résultats fournis par les techniques classiques. L'utilisation de la purge et de l'échantillonnage à faible débit donne des échantillons d'eau souterraine relativement peu perturbés qui sont plus représentatifs des conditions in situ, et le recours aux techniques sans éléments en traces limite l

  1. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    sources of pollution. Ventilation is one of many factors determining IAQ. The aim of DG SANCO funded HealthVent project was to assess how ventilation should be defined in terms of achieving conditions for securing health. Methods: Review of the available literature was made so as to break down the health...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...... of diseases and mortality was used in risk analysis. Ventilation rate was defined as volume of fresh air introduced into the space per person (L/sp). Results: The data in the reviewed studies on ventilation and health were found inadequate to set the health-based ventilation rates mainly because the studies...

  2. National Emission Standards for Hazardous Air Pollutants Calendar Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Technical Services

    2007-06-01

    The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). From 1951 through 1992, the NTS was operated as the nation's site for nuclear weapons testing. The release of man-made radionuclides from the NTS as a result of testing activities has been monitored since the first decade of atmospheric testing. After 1962, when nuclear tests were conducted only underground, the radiation exposure to the public surrounding the NTS was greatly reduced. After the 1992 moratorium on nuclear testing, radiation monitoring on the NTS focused on detecting airborne radionuclides which come from historically-contaminated soils resuspended into the air (e.g., by winds) and tritium-contaminated soil moisture emitted to the air from soils through evapotranspiration.

  3. Manganese testing under a clean air act test rule and the application of resultant data in risk assessments.

    Science.gov (United States)

    Smith, Darcie; Woodall, George M; Jarabek, Annie M; Boyes, William K

    2017-07-01

    In the 1990's, the proposed use of methylcyclopentadienyl manganese tricarbonyl (MMT) as an octane-enhancing gasoline fuel additive led to concerns for potential public health consequences from exposure to manganese (Mn) combustion products in automotive exhaust. After a series of regulatory/legal actions and negotiations, the U.S. Environmental Protection Agency (EPA) issued under Clean Air Act (CAA) section 211(b) an Alternative Tier 2 Test Rule that required development of scientific information intended to help resolve uncertainties in exposure or health risk estimates associated with MMT use. Among the uncertainties identified were: the chemical forms of Mn emitted in automotive exhaust; the relative toxicity of different Mn species; the potential for exposure among sensitive subpopulations including females, the young and elderly; differences in sensitivity between test species and humans; differences between inhalation and oral exposures; and the influence of dose rate and exposure duration on tissue accumulation of Mn. It was anticipated that development of specific sets of pharmacokinetic (PK) information and models regarding Mn could help resolve many of the identified uncertainties and serve as the best foundation for available data integration. The results of the test program included development of several unique Mn datasets, and a series of increasingly sophisticated Mn physiologically-based pharmacokinetic (PBPK) models. These data and models have helped address each of the uncertainties originally identified in the Test Rule. The output from these PBPK models were used by the Agency for Toxic Substances and Disease Registry (ATSDR) in 2012 to inform the selection of uncertainty factors for deriving the manganese Minimum Risk Level (MRL) for chronic exposure durations. The EPA used the MRL in the Agency's 2015 evaluation of potential residual risks of airborne manganese released from ferroalloys production plants. This resultant set of scientific

  4. Risk of exposure to second hand smoke for adolescents in Las Vegas casinos: an evaluation of the Nevada Clean Indoor Air Act.

    Science.gov (United States)

    Cochran, Christopher; Henriques, Dominic; York, Nancy; Lee, Kiyoung

    2012-01-01

    Since the Surgeon General's groundbreaking report of 1964, "Smoking and Health," the medical and scientific communities have uncovered the devastating effects of tobacco smoke on health. In reaction to these findings, local and state governments have enacted a variety of clean air acts to prevent unnecessary exposure to this known carcinogen. The Nevada Clean Indoor Air Act (NCIAA), a non-comprehensive smoke-free law, permits smoking in designated areas of casinos, bars, and taverns. With many Las Vegas casinos catering to all ages, this study was designed to evaluate the efficacy of NCIAA in protecting children from second hand smoke exposure. Using a device that measures ambient air particle matter concentrations, this study sampled the air quality in 15 casino gaming areas and corresponding non-smoking, children-friendly areas. The results indicate that current policy fails to preserve indoor air quality in these children-friendly areas. Furthermore, this research suggests the adoption of a more comprehensive, 100% smoke-free policy as the only effective remedy.

  5. 77 FR 16508 - National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins...

    Science.gov (United States)

    2012-03-21

    ...: Group IV Polymers and Resins; Pesticide Active Ingredient Production; and Polyether Polyols Production... pollutants: National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins...: Group IV Polymers and Resins; Pesticide Active Ingredient Production; and Polyether Polyols...

  6. 55 FR 14037 Correction to the National Emission Standards for Hazardous Air Pollutants

    Science.gov (United States)

    Correction to the National Emission Standards for Hazardous Air Pollutants; Benzene Emissions From Maleic Anhydride Plants, Ethylbenzene/Styrene Plants, Benzene Storage Vessels, Benzene Equipment Leaks, and Coke Byproduct Recovery Plants.

  7. 76 FR 76259 - National Emissions Standards for Hazardous Air Pollutants: Primary Aluminum Reduction Plants

    Science.gov (United States)

    2011-12-06

    ... NTTAA National Technology Transfer and Advancement Act O&M operation and maintenance OAQPS Office of Air Quality Planning and Standards ODW Office of Drinking Water OECA Office of Enforcement and Compliance...

  8. 75 FR 37730 - National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries

    Science.gov (United States)

    2010-06-30

    ... Petroleum Refineries AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule; correction. SUMMARY... air pollutants from heat exchange systems at petroleum refineries. These requirements were published as amendments to the national emission standards for petroleum refineries. In this notice, we are...

  9. Regulatory Actions - Final Mercury and Air Toxics Standards (MATS) for Power Plants

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has proposed Mercury and Air Toxics Standards (MATS) for power plants to limit mercury, acid gases and other toxic pollution from power plants. This page describes Federal regulatory actions.

  10. Regulatory Actions - Proposed Mercury and Air Toxics Standards (MATS) for Power Plants

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has proposed Mercury and Air Toxics Standards (MATS) for power plants to limit mercury, acid gases and other toxic pollution from power plants. This page includes supporting documentation and

  11. Air Force Research to Link Standards for Enlistment to On-the-Job Performance

    Science.gov (United States)

    1991-02-01

    This report describes Air Force research supporting the Joint-Service Job Performance Measurement/Enlistment Standards Project. This project has...selection and classification standards on-the- job performance . This report describes those relationships. A brief overview of the Air Force Job Performance Measurement...enlistment test scores, job experience, educational attainment, and hands-on job performance test scores. Additional analyses indicating the reliability and

  12. 75 FR 19310 - Delegation of New Source Performance Standards and National Emission Standards for Hazardous Air...

    Science.gov (United States)

    2010-04-14

    ... INFORMATION CONTACT: Mr. Kenneth Boyce, Air Planning Section (6PD-L), Environmental Protection Agency, Region...-7263, e-mail address boyce.kenneth@epa.gov . SUPPLEMENTARY INFORMATION: In the final rules section...

  13. Clean Air Act oversight: field hearings. Hearings before the Committee on Environment and Public Works, United States Senate, Ninety-Seventh Congress, First Session, June 27, 1981 Seattle, Washington, June 30, 1981 Randolph, Vermont, July 1, 1981 Albany, New York, July 1, 1981 Fairbanks, Alaska, Part 7

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    Part 7 of the field hearings report covers hearings held on June 27, 1981 in Seattle, Washington, June 30, 1981 in Randolph, Vermont, July 1, 1981 in Albany, NY, and also July 1, 1981 in Fairbanks, Alaska. A total of 122 witnesses appeared to express their views on reauthorizing the Clean Air Act and to suggest possible amendments. Witnesses represented federal and state agencies, local businesses, and public interest groups. Witnesses were asked to address the issues of health standards, the Prevention of Significant Deterioration rule, all air pollutants and the effects, and the lack of clear responsibility and flexibility in the Clean Air Act. Present at the Albany meeting were representatives from the Canadian government, which is concerned with the problem of transboundary pollution. The record includes the testimony and supporting materials submitted for the record. (DCK)

  14. 75 FR 1566 - Public Hearings for Reconsideration of the 2008 National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-01-12

    ... Ambient Air Quality Standards for Ozone AGENCY: Environmental Protection Agency (EPA). ACTION... proposed rule, ``Reconsideration of the 2008 National Ambient Air Quality Standards for Ozone,'' which was... 2008 National Ambient Air Quality Standards for Ozone'' proposed rule should be addressed to Ms....

  15. 76 FR 48073 - Public Hearing for Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and...

    Science.gov (United States)

    2011-08-08

    ... AGENCY 40 CFR Part 50 RIN 2060-AO72 Public Hearing for Secondary National Ambient Air Quality Standards... titled ``Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Sulfur'' which was... ``Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Sulfur'' proposed rule should...

  16. 77 FR 51798 - First Draft Documents Related to the Review of the National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2012-08-27

    ... AGENCY First Draft Documents Related to the Review of the National Ambient Air Quality Standards for... of the Ozone National Ambient Air Quality Standards: First External Review Draft. The Agency is...-001; July 2012), please contact Ms. Karen Wesson, Office of Air Quality Planning and Standards...

  17. 40 CFR 50.11 - National primary and secondary ambient air quality standards for oxides of nitrogen (with...

    Science.gov (United States)

    2010-07-01

    ... air quality standards for oxides of nitrogen (with nitrogen dioxide as the indicator). 50.11 Section... PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS § 50.11 National primary and secondary ambient air quality standards for oxides of nitrogen (with nitrogen dioxide as the indicator). (a) The level of...

  18. 40 CFR Appendix S to Part 50 - Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Nitrogen...

    Science.gov (United States)

    2010-07-01

    ... Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) S Appendix S to Part 50 Protection... National Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) 1. General (a) This... national ambient air quality standards for oxides of nitrogen as measured by nitrogen dioxide (“NO2...

  19. 30 CFR 250.302 - Definitions concerning air quality.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Definitions concerning air quality. 250.302... Definitions concerning air quality. For purposes of §§ 250.303 and 250.304 of this part: Air pollutant means..., pursuant to section 109 of the Clean Air Act, national primary or secondary ambient air quality standards...

  20. Advanced physical coal cleaning to comply with potential air toxic regulations. [Quarterly] technical report, September 1--November 30, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Honaker, R.Q.; Paul, B.C.; Wang, D. [Southern Illinois Univ., Carbondale, IL (United States). Dept. of Mining Engineering

    1994-12-31

    This research project will investigate the use of advanced fine coal cleaning technologies for cleaning PCB feed as a compliance strategy. Trace elements considered in this project will include mercury, selenium, cadmium, and chlorine. Work in the first quarter has focused on trace element analysis procedures and sample acquisition. Several experts in the field of trace element analysis of coal have been consulted and these procedures are presently being evaluated.

  1. Environmental Monitoring, Air Quality - MO 2011 Air Quality Standards Nonattainment Areas (SHP)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — The St. Louis air quality nonattainment areas geospatial data layer contains regions representing the geographic extent of areas that are estimated to be out of...

  2. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  3. National Emission Standards for Hazardous Air Pollutants, June 2005

    Energy Technology Data Exchange (ETDEWEB)

    Robert F. Grossman

    2005-06-01

    The sources of radionuclides include current and previous activities conducted on the NTS. The NTS was the primary location for testing of nuclear explosives in the Continental U.S. between 1951 and 1992. Historical testing has included (1) atmospheric testing in the 1950s and early 1960s, (2) underground testing between 1951 and 1992, and (3) open-air nuclear reactor and rocket engine testing (DOE, 1996a). No nuclear tests have been conducted since September 23,1992 (DOE, 2000), however; radionuclides remaining on the soil surface in many NTS areas after several decades of radioactive decay are re-suspended into the atmosphere at concentrations that can be detected by air sampling. Limited non-nuclear testing includes spills of hazardous materials at the Non-Proliferation Test and Evaluation Complex (formerly called the Hazardous Materials Spill Center), private technology development, aerospace and demilitarization activities, and site remediating activities. Processing of radioactive materials is limited to laboratory analyses; handling, transport, storage, and assembly of nuclear explosive devices or radioactive targets for the Joint Actinide Shock Physics Experimental Research (JASPER) gas gun; and operation of radioactive waste management sites (RWMSs) for low-level radioactive and mixed waste (DOE, 1996a). Monitoring and evaluation of the various activities conducted onsite indicate that the potential sources of offsite radiation exposure in calendar year (CY) 2004 were releases from (1) evaporation of tritiated water (HTO) from containment ponds that receive drainage water from E Tunnel in Area 12 and water pumped from wells used to characterize the aquifers at the sites of past underground nuclear tests, (2) onsite radioanalytical laboratories, (3) the Area 3 and Area 5 RWMS facilities, and (4) diffuse sources of tritium (H{sup 3}) and re-suspension of plutonium ({sup 239+240}Pu) and americium ({sup 241}Am) at the sites of past nuclear tests. The following

  4. 77 FR 16509 - Proposed Approval of Revision of Five California Clean Air Act Title V Operating Permits Programs

    Science.gov (United States)

    2012-03-21

    ... definition of ``regulated air pollutant'' now includes greenhouse gases if the source has a potential to emit... Pollution Control District (MBUAPCD), San Luis Obispo County Air Pollution Control District (SLOCAPCD), Santa Barbara County Air Pollution Control District (SBCAPCD), South Coast Air Quality...

  5. 76 FR 4155 - National Emission Standards for Hazardous Air Pollutants for Source Categories: Gasoline...

    Science.gov (United States)

    2011-01-24

    ... promulgated National Emission Standards for Hazardous Air Pollutants for Source Categories: Gasoline.... Total gasoline consumption is the total used nationwide, so the emission inventory includes emissions... January 24, 2011 Part II Environmental Protection Agency 40 CFR Parts 9 and 63 National Emission Standards...

  6. 78 FR 9623 - Federal Motor Vehicle Safety Standards; Air Brake Systems

    Science.gov (United States)

    2013-02-11

    ... National Highway Traffic Safety Administration 49 CFR Part 571 RIN 2127-AL11 Federal Motor Vehicle Safety... published a final rule that amended the Federal motor vehicle safety standard for air brake systems by... published a final rule in the Federal Register amending Federal Motor Vehicle Safety Standard (FMVSS)...

  7. 78 FR 38001 - Reconsideration of Certain Startup/Shutdown Issues: National Emission Standards for Hazardous Air...

    Science.gov (United States)

    2013-06-25

    ... startup system (like a startup boiler feed pump, if applicable) and transitions to bring emission controls... Emission Standards for Hazardous Air Pollutants From Coal- and Oil- Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-...

  8. 78 FR 14457 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Science.gov (United States)

    2013-03-06

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 60 and 63 RIN 2060-AQ58 National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion...

  9. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  10. Health effects of tropospheric ozone: Review of recent research findings and their implications to ambient air quality standards

    Energy Technology Data Exchange (ETDEWEB)

    Lippmann, M. (New York Univ. Medical Center, Tuxedo (United States))

    1993-01-01

    The US Environmental Protection Agency (EPA) Administrator proposed (on August 3, 1992) to retain the current National Ambient Air Quality Standard (NAAQS) for ozone (O3) on the basis of data assembled in a draft Criteria Document (1986) and its Addendum (1988) which, together with a draft Staff Paper (1988), received public comment and review comments by the EPA's Clean Air Scientific Advisory Committee (CASAC). This paper summarizes and discusses research findings presented since 1988 which, based on the author's experience as a Chairman of CASAC, are most relevant to the promulgation of a primary (health based) NAAQS for O3. These newer findings include substantial evidence from controlled chamber exposure studies and field studies in natural settings that the current NAAQS contains no margin of safety against short-term effects that the EPA has considered to be adverse. They also include evidence from epidemiologic studies that current ambient exposures are associated with reduced baseline lung function, exacerbation of asthma and premature mortality, as well as evidence from chronic animal exposure studies at concentrations within current ambient peak levels that indicate progressive and persistent lung function and structural abnormalities. The current NAAQS, if retained, may therefore also be inadequate to protect the public from effects resulting from chronic exposure to O3. 96 refs.

  11. National Emission Standards for Hazardous Air Pollutants Calendar Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Y. E. Townsend

    2002-06-01

    The Nevada Test Site (NTS) is operated by the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Operations Office (NNSA/NV) as the site for nuclear weapons testing, now limited to readiness activities, experiments in support of the national Stockpile Stewardship Program, and the activities listed below. Located in Nye County, Nevada, the site's southeast corner is about 88 km (55 mi) northwest of the major population center, Las Vegas, Nevada. The NTS covers about 3,561 km2 (1,375 mi2), an area larger than Rhode Island. Its size is 46 to 56 km (28 to 35 mi) east to west and from 64 to 88 km (40 to 55 mi) north to south. The NTS is surrounded, except on the south side, by public exclusion areas (Nellis Air Force Range [NAFR]) that provide another 24 to 104 km (15 to 65 mi) between the NTS and public lands (Figure 1.0). The NTS is characterized by desert valley and Great Basin mountain topography, with a climate, flora, and fauna typical of the southwest deserts. Population density within 150 km (93 mi) of the NTS is only about 0.2 persons per square kilometer, excluding the Las Vegas area. Restricted access, low population density in the surrounding area, and extended wind transport times are advantageous factors for the activities conducted at the NTS. Surface waters are scarce on the NTS, and slow-moving groundwater is present hundreds to thousands of feet below the land surface. The sources of radionuclides include current and previous activities conducted on the NTS (Figure 2.0). The NTS was the primary location for testing of nuclear explosives in the Continental U.S. between 1951 and 1992. Historical testing above or at ground surface has included (1) atmospheric testing in the 1950s and early 1960s, (2) earth-cratering experiments, and (3) open-air nuclear reactor and rocket engine testing. Since the mid-1950s, testing of nuclear explosive devices has occurred underground in drilled vertical holes or in mined tunnels (DOE

  12. Analysis and evaluation methods for chemical contaminants in clean room air; Kagaku osen no bunseki hyokaho clean room kukichu no kagaku osen busshitsu ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, T.

    1998-07-31

    As for, chemical contamination in a cleanroom air has taken up as a important problem. As the main source is building materials, after construction the execution of countermeasures is difficult. Out-gas evaluation and selection in building materials, chemical filters for removing specific organic matter and so on, are a large technical theme in the future and analytical techniques corresponding them become necessary. In this paper, analytical methods of airborne molecular contaminants (AMCs) are introduced. Main samples are AMCs in cleanroom atmosphere, on silicon wafer surface and out-gas from raw materials for cleanroom construction materials such as sealant, plastics and so on. Analytical methods consist of quantification of inorganic compounds, organic compounds and identification of abnormal spot with local/surface analysis. Various interesting findings with analytical data are obtained and investigated. 22 refs., 6 figs., 5 tabs.

  13. Clean air with positive energy balance. Elisabeth hospital in Essen uses energy optimized air conditioning systems; Saubere Luft mit positiver Energiebilanz. Elisabeth-Krankenhaus in Essen nutzt energieoptimierte Lueftungsgeraete

    Energy Technology Data Exchange (ETDEWEB)

    Dunker, Ralf

    2009-02-15

    Thinking on a long-term basis, spontaneously acting - according to this slogan the Elizabeth hospital in Essen (Federal Republic of Germany) converts potentials of energy saving with the facility management. Parallel to the change of the endoscope department and the station Barbara with its 35 beds, the hospital had installed particularly energy-saving air conditioning systems which can be cleaned easily. A view behind the doors of the technology rooms.

  14. Re-evaluation of the product of (W/e)air and the graphite to air stopping-power ratio for 60Co air kerma standards.

    Science.gov (United States)

    Thomson, R M; Rogers, D W O

    2010-07-07

    Experiments which determine the product of (W/e)air, the average energy deposited per coulomb of charge of one sign released by an electron coming to rest in dry air, and (LDelta/rho)Ca, the Spencer-Attix mean restricted mass collision stopping-power ratio for graphite to air, in a 60Co or 137Cs beam are reanalysed. Correction factors, e.g., to account for gaps about a calorimeter core or perturbations due to a cavity's presence, are calculated using the EGSnrc Monte Carlo code system and these generally decrease the value of (W/e)air(LDelta/rho)Ca for each experiment. Stopping-power ratios are calculated for different choices of density correction and average excitation energy (I-value) for graphite. To calculate an average value (W/e)air(LBIPM/rho)Ca for the BIPM air kerma standard, each experimental result is multiplied by the ratio (LBIPM/rho)Ca/(LDelta/Rho)Ca. While individual values of (LDelta/rho)Ca are sensitive to the I-values and density corrections assumed, this ratio varies by less than 0.1% for different choices. Hence, the product (W/e)air(LBIPM/rho)Ca is relatively insensitive to these choices. The weighted mean of the updated data is (W/e)air(LBIPM/rho)Ca=33.68 J C(-1)+/-0.2%, suggesting that the accepted value of 33.97 J C(-1)+/-0.1% is 0.8% too high. This has implications for primary 60Co air kerma standards worldwide and potentially for the choice of graphite I-value and density correction for the calculation of the graphite stopping power, as well as the value of (W/e)air.

  15. Particulate Air Pollution and Health: Emerging Issues and Research Needs Related to the Development of Air Quality Standards

    Directory of Open Access Journals (Sweden)

    Patrick A Hessel

    1997-01-01

    Full Text Available The health effects of particulate air pollution were highlighted at the Eighth Annual Conference of the International Society for Environmental Epidemiology, held in Edmonton, Alberta in August 1996. Despite consistent evidence for adverse respiratory and cardiovascular health effects related to particulate air pollution, there are significant gaps in the knowledge of the mechanisms whereby particulate air pollution affects human health. Questions regarding the appropriate measure of dose for assessing exposures relevant to health outcomes and the methods used to analyze dose-response data remain unanswered. Health effects have been demonstrated across the range of exposures that have been examined, and further research in low exposure settings is necessary to explore the lower end of the dose-response curve. Although a significant body of literature has been generated, comprehensive risk assessments have not been undertaken. Examination of the chronic effects of particulate air pollution and identification of high risk populations are necessary. Although there are significant unanswered questions regarding the health effects of particulate air pollution, the available information suggests that particulate air pollution at levels consistent with current standards is associated with measurable health effects.

  16. [Implementation results of emission standards of air pollutants for thermal power plants: a numerical simulation].

    Science.gov (United States)

    Wang, Zhan-Shan; Pan, Li-Bo

    2014-03-01

    The emission inventory of air pollutants from the thermal power plants in the year of 2010 was set up. Based on the inventory, the air quality of the prediction scenarios by implementation of both 2003-version emission standard and the new emission standard were simulated using Models-3/CMAQ. The concentrations of NO2, SO2, and PM2.5, and the deposition of nitrogen and sulfur in the year of 2015 and 2020 were predicted to investigate the regional air quality improvement by the new emission standard. The results showed that the new emission standard could effectively improve the air quality in China. Compared with the implementation results of the 2003-version emission standard, by 2015 and 2020, the area with NO2 concentration higher than the emission standard would be reduced by 53.9% and 55.2%, the area with SO2 concentration higher than the emission standard would be reduced by 40.0%, the area with nitrogen deposition higher than 1.0 t x km(-2) would be reduced by 75.4% and 77.9%, and the area with sulfur deposition higher than 1.6 t x km(-2) would be reduced by 37.1% and 34.3%, respectively.

  17. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Apte, Mike G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-10-31

    This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These

  18. Air Dashboard Help | ECHO | US EPA

    Science.gov (United States)

    The dashboards found on the Enforcement and Compliance History Online (ECHO) website are specialized to track both facility and agency performance as they relate to compliance with and enforcement of environmental standards under the Clean Air Act (CAA).

  19. Stability results of a free air ionization chamber in standard mammography beams

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natalia F.; Xavier, Marcos; Vivolo, Vitor; Caldas, Linda V.E., E-mail: nsilva@ipen.br, E-mail: mxavier@ipen.br, E-mail: vivolo@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Free air ionization chambers are absolute dosimeters, because they can measure basic physical quantities directly without the need of their calibration in a standard radiation beam. They are used for measuring exposure and air kerma in X and gamma radiation beams. The Calibration Laboratory (LCI) of IPEN has a free air ionization chamber of the cylindrical type for low energies. The characterization of this ionization chamber was already performed and reported in a previous study. After a modification in the support of the micrometers used for the movement of the internal cylinder devices, the tests were redone. The objective of this work was to present the new alignment protocol of the free air ionization chamber in low energies of X-ray beams of standard mammography qualities, assuring the positioning reproducibility, and new results of stability tests performed with the application of this protocol will be presented. (author)

  20. 78 FR 47480 - Nineteenth Meeting: RTCA Special Committee 214/EUROCAE WG-78: Standards for Air Traffic Data...

    Science.gov (United States)

    2013-08-05

    ... for Air Traffic Data Communication Services AGENCY: Federal Aviation Administration (FAA), U.S...: Standards for Air Traffic Data Communication Services meeting. SUMMARY: The FAA is issuing this notice to...-78: Standards for Air Traffic Data Communication Services. DATES: The meeting will be held August 26...

  1. National Emission Standards for Hazardous Air Pollutants—Calendar Year 2010 INL Report for Radionuclides (2011)

    Energy Technology Data Exchange (ETDEWEB)

    Mark Verdoorn; Tom Haney

    2011-06-01

    This report documents the calendar Year 2010 radionuclide air emissions and resulting effective dose equivalent to the maximally exposed individual member of the public from operations at the Department of Energy's Idaho National Laboratory Site. This report was prepared in accordance with the Code of Federal Regulations, Title 40, 'Protection of the Environment,' Part 61, 'National Emission Standards for Hazardous Air Pollutants,' Subpart H, 'National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities.'

  2. Using soil records with atmospheric dispersion modeling to investigate the effects of clean air regulations on 60 years of manganese deposition in Marietta, Ohio (USA).

    Science.gov (United States)

    Carter, Megan R; Gaudet, Brian J; Stauffer, David R; White, Timothy S; Brantley, Susan L

    2015-05-15

    Atmospheric emissions of metals from anthropogenic activities have led to deposition and contamination of soils worldwide. We quantified addition of manganese (Mn) to soils around the largest emitter of Mn in the United States (U.S.) using chemical analyses and atmospheric dispersion modeling (Second-Order Closure Integrated Puff (SCIPUFF)). Concentrations of soil-surface Mn were enriched by 9-fold relative to that of the parent material within 1 km of the facility. Elevated concentrations of Mn and chromium (Cr), another potentially toxic element that was emitted, document contamination only within 1 m of the soil surface. Total mass of Mn added per unit land area integrated over 1 m, mMn, equals ~80 mg Mn cm(-2) near the facility. Values of mMn remained above background up to tens of kilometers from the source. Air concentrations of Mn particles of 7.5-micron diameter simulated with SCIPUFF using available data for the emission rate and local meteorological conditions for 2006 were consistent with measured air concentrations. However, the Mn deposition calculated for 2006 with SCIPUFF yielded a cumulative value over the lifetime of the refinery (60 years) that is a factor of 15 lower than the Mn observed to have been added to the soils. This discrepancy can be easily explained if Mn deposition rates before 1988 were more than an order of magnitude greater than today. Such higher emissions are probable, given the changes in metal production with time and the installation of emission controls after the Clean Air Act (1970). This work shows that atmospheric dispersion models can be used with soil profiles to understand the changes in metal emissions over decadal timescales. In addition, the calculations are consistent with the Clean Air Act accounting for a 15-fold decrease in the Mn deposition to soils around the refinery per metric ton of Mn alloy produced. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Study on Cleaning Methods of Central Air Conditioning Water Cystem%中央空调水系统的清洗方法研究

    Institute of Scientific and Technical Information of China (English)

    刘孝刚

    2014-01-01

    为提高换热效率、防止和减少水的腐蚀,中央空调的冷却水系统和冷冻水系统都应定期进行清洗,以除去金属表面上的沉积物和杀灭微生物。对于新建的中央空调,其冷却水和冷冻水系统中的设备在制造加工中和运输储存期间都会发生锈蚀,带入的切削油、防锈油严重影响中央空调水系统的运行,在安装过程中还会下碎屑、油类、泥砂和杂质。因此,对中央空调水系统的清洗方法的研究显得尤为重要。%In order to improve thermal efficiency, prevent and reduce the corrosion of water, the cooling water system and chilled water system of central air conditioning should be regular cleaning, so as to remove sediments on the surface of metals and exterminate microorganisms. In term of the new central air conditioning, the equipments of cooling water system and chilled water system would be easily corroded in the process of manufacturing , storage and transportation, cutting oil, rust-proof oil brought in would seriously affect the operation of central air conditioning water system, during the installation process there will be fallen debris, oil, mud, sand and impurities. Therefore, the study of the central air conditioning water system cleaning methods is particularly important.

  4. Implications of OSHA's reliance on TLVs in developing the air contaminants standard

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, J.C.; Paxman, D.G.; Rappaport, S.M. (Univ. of California, Berkeley (USA))

    1991-01-01

    This paper evaluates the decision by the Occupational Safety and Health Administration (OSHA) to base its Air Contaminants Standard on the threshold limit values (TLVs) of the American Conference of Governmental Industrial Hygienists. Contrary to the claim made by OSHA in promulgating the standard, the TLV list was not the sole available basis for a generic standard covering toxic air contaminants. The National Institute for Occupational Safety and Health (NIOSH) presented data indicating that the TLVs were insufficiently protective for 98 substances. NIOSH Recommended Exposure Limits (RELs) were available for 59 of these substances. The ratio of PEL to REL ranged up to 1,000, with a median of 2.5 and a mean of 71.4. OSHA excluded 42 substances from the standard altogether despite the availability of NIOSH RELs, solely because no TLV had been established.

  5. 76 FR 17473 - Twelfth Meeting: RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data...

    Science.gov (United States)

    2011-03-29

    ... Federal Aviation Administration Twelfth Meeting: RTCA Special Committee 214: Working Group 78: Standards...: Notice of RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data Communication... Committee 214: Working Group 78: Standards for Air Traffic Data Communication Services. DATES: The...

  6. 75 FR 20423 - Tenth Meeting: RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data...

    Science.gov (United States)

    2010-04-19

    ... Federal Aviation Administration Tenth Meeting: RTCA Special Committee 214: Working Group 78: Standards for...: Notice of RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data Communication... Committee 214: Working Group 78: Standards for Air Traffic Data Communication Services. DATES: The...

  7. 75 FR 66828 - Eleventh Meeting: RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data...

    Science.gov (United States)

    2010-10-29

    ... Federal Aviation Administration Eleventh Meeting: RTCA Special Committee 214: Working Group 78: Standards...: Notice of RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data Communication... Committee 214: Working Group 78: Standards for Air Traffic Data Communication Services. DATES: The...

  8. Analysis of the Clean Air Act Amendments of 1990: A forecast of the electric utility industry response to Title IV, Acid Deposition Control

    Energy Technology Data Exchange (ETDEWEB)

    Molburg, J.C.; Fox, J.A.; Pandola, G.; Cilek, C.M.

    1991-10-01

    The Clean Air Act Amendments of 1990 incorporate, for the first time, provisions aimed specifically at the control of acid rain. These provisions restrict emissions of sulfur dioxide (SO{sub 2}) and oxides of nitrogen (NO{sub x}) from electric power generating stations. The restrictions on SO{sub 2} take the form of an overall cap on the aggregate emissions from major generating plants, allowing substantial flexibility in the industry`s response to those restrictions. This report discusses one response scenario through the year 2030 that was examined through a simulation of the utility industry based on assumptions consistent with characterizations used in the National Energy Strategy reference case. It also makes projections of emissions that would result from the use of existing and new capacity and of the associated additional costs of meeting demand subject to the emission limitations imposed by the Clean Air Act. Fuel-use effects, including coal-market shifts, consistent with the response scenario are also described. These results, while dependent on specific assumptions for this scenario, provide insight into the general character of the likely utility industry response to Title IV.

  9. Analysis of the Clean Air Act Amendments of 1990: A forecast of the electric utility industry response to Title IV, Acid Deposition Control

    Energy Technology Data Exchange (ETDEWEB)

    Molburg, J.C.; Fox, J.A.; Pandola, G.; Cilek, C.M.

    1991-10-01

    The Clean Air Act Amendments of 1990 incorporate, for the first time, provisions aimed specifically at the control of acid rain. These provisions restrict emissions of sulfur dioxide (SO[sub 2]) and oxides of nitrogen (NO[sub x]) from electric power generating stations. The restrictions on SO[sub 2] take the form of an overall cap on the aggregate emissions from major generating plants, allowing substantial flexibility in the industry's response to those restrictions. This report discusses one response scenario through the year 2030 that was examined through a simulation of the utility industry based on assumptions consistent with characterizations used in the National Energy Strategy reference case. It also makes projections of emissions that would result from the use of existing and new capacity and of the associated additional costs of meeting demand subject to the emission limitations imposed by the Clean Air Act. Fuel-use effects, including coal-market shifts, consistent with the response scenario are also described. These results, while dependent on specific assumptions for this scenario, provide insight into the general character of the likely utility industry response to Title IV.

  10. Comparing toxic air pollutant programs

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, S.C. [ECKENFELDER Inc., Greenville, SC (United States)

    1997-05-01

    This article compares state and federal toxic air pollutant programs. The Clean Air Act Ammendments created a program for the control of Hazardous Air Pollutants based on the establishment of control technology standards. State toxic programs can be classified into two categories: control technology-based and ambient concentration-based. Many states have opened to implement the MACT standards while enforcing their own state air toxics programs. Specific topics discussed include the following: the Federal air toxics program; existing state regulations; New Jersey Air Toxic Program; New York Toxics program.

  11. Advanced physical coal cleaning to comply with potential air toxic regulations. Quarterly report, 1 March 1995--31 May 1995

    Energy Technology Data Exchange (ETDEWEB)

    Honaker, R.Q.; Paul, B.C.; Mohanty, M.K.; Wang, D.

    1995-12-31

    Studies have indicated that the potentially hazardous trace elements found in coal have a strong affinity for coal pyrite. Thus, by maximizing the rejection of pyrite, one can minimize the trace element content of a given coal while also reducing sulfur emissions. The pyrite in most Illinois Basin coals, however, is finely disseminated within the coal matrix. Therefore, to remove the pyrite using physical coal cleaning techniques, the pyrite must be liberated by grinding the coal to ultrafine particle sizes. Fortunately, the coals being fed to pulverized coal boilers (PCB) are already ground to a very fine size, i.e., 70% passing 200 mesh. Therefore, this research project will investigate the use of advanced fine coal cleaning technologies for cleaning PCB feed as a compliance strategy. Work in this quarter has focused on the processing of a run-of-mine coal sample collected from Amax Coal Company`s Delta Coal mine using column flotation and an enhanced gravity separator as separate units and in circuitry arrangements. The {minus}60 mesh run-of-mine sample having an ash content of about 22% was cleaned to 6% while achieving a very high energy recovery of about 87% and a sulfur rejection value of 53% in a single stage column flotation operation. Enhanced gravity treatment is believed to be providing excellent total sulfur rejection values, although with inferior ash rejection for the {minus}400 mesh size fraction. The circuitry arrangement with the Falcon concentrator as the primary cleaner followed by the Packed-Column resulted in an excellent ash rejection performance, which out performed the release analysis. Trace element analyses of the samples collected from these tests will be conducted during the next report period.

  12. Advanced physical coal cleaning to comply with potential air toxic regulations. Quarterly report, 1 December 1994--28 February 1995

    Energy Technology Data Exchange (ETDEWEB)

    Honaker, R.Q.; Paul, B.C.; Wang, D.

    1995-12-31

    Studies have indicated that the potentially hazardous trace elements found in coal have a strong affinity for coal pyrite. Thus, by maximizing the rejection of pyrite, one can minimize the trace element content of a given coal while also reducing sulfur emissions. The pyrite in most Illinois Basin coals, however, is finely disseminated within the coal matrix. Therefore, to remove the pyrite using physical coal cleaning techniques, the pyrite must be liberated by grinding the coal to ultrafine particle sizes. Fortunately, the coals being fed to pulverized coal boilers (PCB) are already ground to a very fine size, i.e., 70% passing 200 mesh. Therefore, this research project will investigate the use of advanced fine coal cleaning technologies for cleaning PCB feed as a compliance strategy. Work in this quarter has focused on the processing of a PCB feed sample collected from Central Illinois Power`s Newton Power Station using column flotation and an enhanced gravity separator as separate units and in a circuitry arrangement. The PCB feed sample having a low ash content of about 12% was further cleaned to 6% while achieving a very high energy recovery of about 90% in a single stage column flotation operation. Enhanced gravity treatment is believed to be providing excellent total sulfur rejection values, although with inferior ash rejection for the {minus}400 mesh size fraction. The circuitry arrangement with the Falcon concentrator as the primary cleaner followed by the Microcel column resulted in an excellent ash rejection performance, which out performed the release analysis. Trace element analyses of the samples collected from these tests will be conducted during the next report period.

  13. Technological, economic, and political feasibility in OSHA's Air Contaminants Standard

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, J.C.; Paxman, D.G. (Univ. of California, Berkeley (USA))

    In 1989, after almost two decades of substance-by-substance standard setting, the Occupational Safety and Health Administration (OSHA) promulgated its Air Contaminants Standard, imposing new exposure limits for 376 toxic substances encountered in U.S. industry. In marked contrast to earlier regulations, the Air Contaminants Standard has generated relatively little industry opposition. This paper analyzes the standard in the context of the twenty-year debate over the appropriate role for technological feasibility and economic compliance costs in occupational health policy. The political feasibility of the new standard is traced to OSHA's abandonment of technology forcing in favor of reliance on off-the-shelf technologies already in use in major firms. While important as an embodiment of OSHA's new generic approach to regulation, the Air Contaminants Standard cannot serve as a model for future occupational health policy, due to its reliance on informal, closed-door mechanisms for establishing regulatory priorities and permissible exposure limits. 20 refs.

  14. Clean Water Act

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Clean Water Act (CWA) establishes the basic structure for regulating discharges of pollutants into U.S. waters and regulating quality standards for surface...

  15. A primary standard for activity concentration of {sup 220}Rn (thoron) in air

    Energy Technology Data Exchange (ETDEWEB)

    Roettger, Annette, E-mail: Annette.roettger@ptb.d [Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig (Germany); Honig, Anja; Dersch, Rainer; Ott, Oliver; Arnold, Dirk [Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig (Germany)

    2010-07-15

    Due to the short half-life of Rn-220, a primary standard for activity concentration of Rn-220 (thoron) in air (i.e. a homogeneous reference atmosphere consisting of a certified activity in a certified volume) has been considered unachievable in the past. Traceability of Rn-222 reference atmospheres is achievable using radon gas activity standards (; ) and standard volumes, and is an established method. For the short-lived radionuclide Rn-220 this procedure is not feasible, since no Rn-220 gas activity standard with a reasonable activity can be produced. This leads to a lack of traceability for measurements of Rn-220 activity concentration: only atmospheres monitored by reference instruments (i.e. secondary standards) are available. The new primary standard for the activity concentration of {sup 220}Rn developed by PTB now closes this gap in radon metrology.

  16. 77 FR 15267 - Clean Air Act Full Approval of Title V Operating Permits Program; Southern Ute Indian Tribe

    Science.gov (United States)

    2012-03-15

    ... review of the Tribe's authority to regulate air pollution sources located within the exterior boundaries... jurisdiction to regulate non- Indian-owned air pollution sources located on fee lands within the Reservation... greenhouses gases as part of the Prevention of Significant Deterioration/Title V Greenhouse Gas Tailoring...

  17. 76 FR 30604 - National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers...

    Science.gov (United States)

    2011-05-26

    ... Polyvinyl Chloride and Copolymers Production AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed..., the proposed rule, National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and... Polyvinyl Chloride and Copolymers Production, under Docket ID No. EPA-HQ-OAR-2002-0037 (available at...

  18. 77 FR 1267 - National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins...

    Science.gov (United States)

    2012-01-09

    ... products are used for applications in packaging, building and construction. We identified two currently...--National Emission Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical...--Polycyclic Organic Matter PRD--Pressure Relief Device RACT--Reasonably Available Control Technology...

  19. 40 CFR 60.752 - Standards for air emissions from municipal solid waste landfills.

    Science.gov (United States)

    2010-07-01

    ... municipal solid waste landfills. 60.752 Section 60.752 Protection of Environment ENVIRONMENTAL PROTECTION... of Performance for Municipal Solid Waste Landfills § 60.752 Standards for air emissions from municipal solid waste landfills. (a) Each owner or operator of an MSW landfill having a design capacity...

  20. 75 FR 65594 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Particulate Matter Standards

    Science.gov (United States)

    2010-10-26

    .... Hand Delivery: Jay Bortzer, Chief, Air Programs Branch (AR-18J), U.S. Environmental Protection Agency... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION... Matter Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: EPA...

  1. 76 FR 42052 - National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries

    Science.gov (United States)

    2011-07-18

    ... Petroleum Refineries AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule; partial withdrawal... Petroleum Refineries. EPA is now providing final notice of the partial withdrawal. DATES: As of August 17... signed a final rule amending the National Emission Standards for Hazardous Air Pollutants From Petroleum...

  2. [European community guidelines and standards in indoor air quality: what proposals for Italy].

    Science.gov (United States)

    Settimo, Gaetano; D'Alessandro, Daniela

    2014-01-01

    Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.

  3. Evaluating a pneumatic fractionator for cleaning ginned lint

    Science.gov (United States)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. An experiment was conducted to evaluate the pneumatic fractionator as a lint cleaning device. No modifications were made to the standard device, except that air p...

  4. Clean data

    CERN Document Server

    Squire, Megan

    2015-01-01

    If you are a data scientist of any level, beginners included, and interested in cleaning up your data, this is the book for you! Experience with Python or PHP is assumed, but no previous knowledge of data cleaning is needed.

  5. Laser ablative fluxless soldering (LAFS): 60Sn-40Pb solder wettability tests on laser cleaned OFHC copper substrates

    Energy Technology Data Exchange (ETDEWEB)

    Peebles, H. C.; Keicher, D. M.; Hosking, F. M.; Hlava, P. F.; Creager, N. A.

    1991-01-01

    OFHC copper substrates, cleaned by laser ablation under argon and helium gas, were tested for solder wettability by 60Sn-40Pb using an area-of-spread method. The wettability of copper surfaces cleaned under both argon and helium gas was found to equal or exceed the wettability obtained on this surface in air using a standard RMA flux. The area of spread on copper substrates cleaned under helium was eight times larger than the area of spread of substrates cleaned under argon. The enhanced spreading observed on the substrates cleaned under helium gas was found to be due to surface roughness. 11 refs., 8 figs., 2 tabs.

  6. National Emission Standards for Hazardous Air Pollutants—Calendar Year 2011 INL Report for Radionuclides (2012)

    Energy Technology Data Exchange (ETDEWEB)

    Mark Verdoorn; Tom Haney

    2012-06-01

    This report documents the calendar year 2011 radionuclide air emissions and resulting effective dose equivalent to the maximally exposed individual member of the public from operations at the Department of Energy's Idaho National Laboratory Site. This report was prepared in accordance with the Code of Federal Regulations, Title 40, 'Protection of the Environment,' Part 61, 'National Emission Standards for Hazardous Air Pollutants,' Subpart H, 'National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities.' The effective dose equivalent to the maximally exposed individual member of the public was 4.58E-02 mrem per year, 0.46 percent of the 10 mrem standard.

  7. National Emission Standards for Hazardous Air Pollutants. Calendar Year 2013 INL Report for Radionuclides [2014

    Energy Technology Data Exchange (ETDEWEB)

    Verdoorn, Mark; Haney, Tom

    2014-06-01

    This report documents the calendar year 2013 radionuclide air emissions and resulting effective dose equivalent to the maximally exposed individual member of the public from operations at the Department of Energy’s Idaho National Laboratory Site. This report was prepared in accordance with the Code of Federal Regulations, Title 40, ''Protection of the Environment,'' Part 61, ''National Emission Standards for Hazardous Air Pollutants,'' Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities.'' The effective dose equivalent to the maximally exposed individual member of the public was 3.02 E-02 mrem per year, 0.30 percent of the 10 mrem standard.

  8. National Emission Standards for Hazardous Air Pollutants. Calendar Year 2012 INL Report for Radionuclides (2013)

    Energy Technology Data Exchange (ETDEWEB)

    Verdoorn, Mark; Haney, Tom

    2013-06-01

    This report documents the calendar year 2011 radionuclide air emissions and resulting effective dose equivalent to the maximally exposed individual member of the public from operations at the Department of Energy’s Idaho National Laboratory Site. This report was prepared in accordance with the Code of Federal Regulations, Title 40, ''Protection of the Environment,'' Part 61, ''National Emission Standards for Hazardous Air Pollutants,'' Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities.'' The effective dose equivalent to the maximally exposed individual member of the public was 4.58E-02 mrem per year, 0.46 percent of the 10 mrem standard.

  9. Air-kerma determination using a variable-volume cavity ionization chamber standard.

    Science.gov (United States)

    Burns, D T; Kessler, C; Roger, P

    2007-12-01

    A graphite-walled cavity ionization chamber of modular design and variable volume has been used to determine the air-kerma rate in the reference 60Co field at the BIPM. The chamber can be configured in five sizes. High-accuracy mechanical measurements of the volume of the air cavity were made for each configuration using a co-ordinate measuring machine. Ionization current measurements were made for each configuration and corrected for the effects of ion recombination and diffusion, stem scatter and chamber orientation. Monte Carlo calculations of cavity dose were made to evaluate the correction factors kwall and kan. A reproducibility of the ionization current per mass of 1.5 parts in 10(4) was achieved on the repeated assembly of each configuration. The results show an air-kerma rate determination that increases with volume, the total change being around 8 parts in 10(4). When analysed differentially, the air-kerma rate relative to the BIPM standard is Kdiff/KBIPM = 1.0026(6). A detailed uncertainty budget is presented. Possible reasons for the observed behaviour are discussed that might have consequences for all existing standards for air-kerma.

  10. 中央空调风系统管道清洗的调查探讨%On exploration for investigation of pipeline cleaning of central air-conditioner wind system

    Institute of Scientific and Technical Information of China (English)

    温嘉

    2012-01-01

    The study illustrates the necessity for the cleaning of the central air-conditioner system,introduces the development status and problems in the cleaning industry of the central pipeline air-conditioner system at home and abroad,and has the perspective for the future of the cleaning industry of the central air-conditioner system in China.%阐述了中央空调风系统清洗的必要性,介绍了国内外中央空调风系统管道清洗行业的发展状况和存在的问题,展望了我国中央空调风系统管道清洗行业发展的大好前景。

  11. Using National Ambient Air Quality Standards for fine particulate matter to assess regional wildland fire smoke and air quality management.

    Science.gov (United States)

    Schweizer, Don; Cisneros, Ricardo; Traina, Samuel; Ghezzehei, Teamrat A; Shaw, Glenn

    2017-10-01

    Wildland fire is an important ecological process in the California Sierra Nevada. Personal accounts from pre-20th century describe a much smokier environment than present day. The policy of suppression beginning in the early 20th century and climate change are contributing to increased megafires. We use a single particulate monitoring site at the wildland urban interface to explore impacts from prescribed, managed, and full suppression wildland fires from 2006 to 2015 producing a contextual assessment of smoke impacts over time at the landscape level. Prescribed fire had little effect on local fine particulate matter (PM2.5) air quality with readings typical of similar non-fire times; hourly and daily good to moderate Air Quality Index (AQI) for PM2.5, maximum hourly concentrations 21-103 μg m(-3), and mean concentrations between 7.7 and 13.2 μg m(-3). Hourly and daily AQI was typically good or moderate during managed fires with 3 h and one day reaching unhealthy while the site remained below National Ambient Air Quality Standards (NAAQS), with maximum hourly concentrations 27-244 μg m(-3), and mean concentrations 6.7-11.7 μg m(-3). The large high intensity fire in this area created the highest short term impacts (AQI unhealthy for 4 h and very unhealthy for 1 h), 11 unhealthy for sensitive days, and produced the only annual value (43.9 μg m(-3)) over the NAAQS 98th percentile for PM2.5 (35 μg m(-3)). Pinehurst remained below the federal standards for PM2.5 when wildland fire in the local area was managed to 7800 ha (8-22% of the historic burn area). Considering air quality impacts from smoke using the NAAQS at a landscape level over time can give land and air managers a metric for broader evaluation of smoke impacts particularly when assessing ecologically beneficial fire. Allowing managers to control the amount and timing of individual wildland fire emissions can help lessen large smoke impacts to public health from a megafire. Published by

  12. Relating health and climate impacts to grid-scale emissions using adjoint sensitivity modeling for the Climate and Clean Air Coalition

    Science.gov (United States)

    Henze, D. K.; Lacey, F.; Seltzer, M.; Vallack, H.; Kuylenstierna, J.; Bowman, K. W.; Anenberg, S.; Sasser, E.; Lee, C. J.; Martin, R.

    2013-12-01

    The Climate and Clean Air Coalition (CCAC) was initiated in 2012 to develop, understand and promote measures to reduce short lived climate forcers such as aerosol, ozone and methane. The Coalition now includes over 30 nations, and as a service to these nations is committed to providing a decision support toolkit that allows member nations to explore the benefits of a range of emissions mitigation measures in terms of the combined impacts on air quality and climate and so help in the development of their National Action Plans. Here we will present recent modeling work to support the development of the CCAC National Action Plans toolkit. Adjoint sensitivity analysis is presented as a means of efficiently relating air quality, climate and crop impacts back to changes in emissions from each species, sector and location at the grid-scale resolution of typical global air quality model applications. The GEOS-Chem adjoint model is used to estimate the damages per ton of emissions of PM2.5 related mortality, the impacts of ozone precursors on crops and ozone-related health effects, and the combined impacts of these species on regional surface temperature changes. We show how the benefits-per-emission vary spatially as a function of the surrounding environment, and how this impacts the overall benefit of sector-specific control strategies. We present initial findings for Bangladesh, as well as Mexico, Ghana and Colombia, some of the first countries to join the CCAC, and discuss general issues related to adjoint-based metrics for quantifying air quality and climate co-benefits.

  13. 78 FR 76888 - Twentieth Meeting: RTCA Special Committee 214/EUROCAE WG-78: Standards for Air Traffic Data...

    Science.gov (United States)

    2013-12-19

    ... Air Traffic Data Communication Services AGENCY: Federal Aviation Administration (FAA), U.S. Department... for Air Traffic Data Communication Services meeting. SUMMARY: The FAA is issuing this notice to advise...: Standards for Air Traffic Data Communication Services. DATES: The meeting will be held January 13-17 from 9...

  14. Health benefits of a reduction of PM10 and NO2 exposure after implementing a clean air plan in the Agglomeration Lausanne-Morges.

    Science.gov (United States)

    Castro, Alberto; Künzli, Nino; Götschi, Thomas

    2017-07-01

    Exposure to urban air pollution has been associated with adverse effects on cardio-vascular and respiratory health, both short and long term. Consequently, governments have applied policies to reduce air pollution. Quantitative health impact assessments of hypothetic changes in air pollution have been conducted at national and global level, but assessments of observed air pollution changes associated with specific clean air policies at a local or regional scale remain scarce. This study estimates health impacts attributable to a decrease in PM10 and NO2 exposure in the Agglomeration of Lausanne-Morges (ALM), Switzerland, between 2005 and 2015, corresponding to the implementation period of a supra-municipal plan of measures to reduce air pollution in different sectors such as transport, energy, and industry (called Plan OPair 05). The health impact assessment compares health effects attributed to air pollution exposure levels in 2015 (reference case) with those in 2005 (counterfactual scenario), using 2015 as baseline for all other input data. In the ALM, the modeled PM10 exposure reduction of 3.3μg/m(3) from 2005 to 2015 prevents 26 premature deaths (equivalent to around 290 years of life lost), 215 hospitalization days due to cardio-vascular and respiratory diseases as well as approximately 47,000 restricted activity days annually. Monetized health impacts of the reduction of PM10 exposure are valued at approximately CHF 36 million annually. Immaterial costs, mainly related to the economic valuation of years of life lost, dominate the monetized health impacts (90% of total value), while savings at the workplace (net loss in production and reoccupation costs) amount to about CHF 1.9 million, and savings in health care costs to about CHF 0.5 million. The assessment is sensitive to the value assigned to immaterial costs and to uncertainties in the relative risk estimates, whereas variations in the baseline year (i.e. using 2005 data instead of 2015 data) affect

  15. 76 FR 58078 - Thirteenth Meeting: RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data...

    Science.gov (United States)

    2011-09-19

    ... Federal Aviation Administration Thirteenth Meeting: RTCA Special Committee 214: Working Group 78.... ACTION: Notice of RTCA Special Committee 214: Working Group 78: Standards for Air Traffic Data... Special Committee 214: Working Group 78: Standards for Air Traffic Data Communication Services. DATES:...

  16. 40 CFR Appendix R to Part 50 - Interpretation of the National Ambient Air Quality Standards for Lead

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Interpretation of the National Ambient Air Quality Standards for Lead R Appendix R to Part 50 Protection of Environment ENVIRONMENTAL.... 50, App. R Appendix R to Part 50—Interpretation of the National Ambient Air Quality Standards for...

  17. Criminal provisions of the Clean Air Act Amendments of 1990 and their interface with the United States sentencing guidelines. Master's thesis

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, W.P.

    1991-09-30

    The growing severity of our societal response to environmental misconduct is reflected, in part, by the criminalization of environmental wrongs by both state and Federal governments. Indeed, the recently enacted Clean Air Act Amendments of 1990 continue this trend, giving the Environmental Protection Agency, via the Department of Justice, significant new criminal enforcement tools. The importance attached to law enforcement of environmental laws is a relatively recent phenomenon and took a significant upswing in 1982 when the department of Justice created what is today the Environmental Crimes Section in what is now the Environment and Natural Resources Division, which section has grown steadily and now has over 25 attorneys who prosecute or assist in the prosecution of environmental crimes in the U.S.

  18. National ambient air quality standards : proposed decisions on particulate matter and ozone

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    Ontario receives significant levels of transboundary air pollution from the United States. The pollution consists of particulate matter and ozone precursors such as nitrogen oxides and volatile organic compounds. During hot summer days, more than 50 per cent of the ozone affecting Ontario comes from the United States. The Ontario government has reviewed the U.S.`s proposed standards relating to particulate matter and ozone. This report presents Ontario`s analysis of the proposed new U.S. standards for particulates and ozone, and Ontario`s request for more stringent standards than those proposed by the Environmental Protection Agency. The derivation of proposed standards and the risk assessments related to the pollutants is also discussed. 11 tabs.

  19. 76 FR 21345 - Science Advisory Board Staff Office; Notification of Two Public Teleconferences of the Clean Air...

    Science.gov (United States)

    2011-04-15

    ... plans for Photochemical Assessment Monitoring Stations (PAMS) Network Re-engineering. DATES: Two public... EPA CASAC Web site at http://www.epa.gov/casac . Any inquiry regarding EPA's PAMS Network Re... plans for PAMS Network Re-engineering. EPA's Office of Air and Radiation (OAR) designed the PAMS...

  20. Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Iyer, Maithili

    2007-03-01

    The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented

  1. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measurements included testing of the filters, separately and combined, in a ductwork to study the efficiency...... of the filters. The removal efficiency of the mechanical filter for ultrafine particles was examined using burning candles as sources for emission of particles. The measurements in the duct showed that the efficiency of the particle filter ranged between approximately 50% and 80% and the pressure loss...... of gases. The measurement results showed that the efficiency of the combined filters ranged between approximately 30% and 80% and the pressure loss was less than approximately 20 Pascal at an airflow rate of 250 m3/h....

  2. 2007 Critical Review Discussion -- Will the circle be unbroken: a history of the U.S. national ambient air quality standards

    Energy Technology Data Exchange (ETDEWEB)

    Judith C. Chow; John G. Watson; Howard J. Feldman (and others) [Desert Research Institute, Reno, NV (United States)

    2007-10-15

    In the review, John D. Bachmann traces the regulatory history of U.S. air pollution from the beginning of the 20th century to the present. The review divides this progress into four segments: (1) 1900-1970, from smoke abatement to federal involvement and the establishment of air quality management (AQM) in the 1970 Clean Air Act (CAA); (2) 1971-1976, when the first National Ambient Air Quality Standards (NAAQS) were promulgated and implemented; (3) 1977-1993, which included the first NAAQS revisions, major CAA amendments, and the evolution of AQM; and (4) 1993-2006, the second and third waves of NAAQS revisions and their implementation in the context of the 1990 CAA amendments. A discussant's commentary does not necessarily reflect the position of his or her respective organization. This Critical Review Discussion was compiled from written submissions and presentation transcripts. The invited discussants are as follows: Mr. Howard J. Feldman, director of regulatory and scientific affairs for the American Petroleum Institute; Ms. Janice E. Nolen, assistant vice president of national policy and advocacy for the American Lung Association; Dr. Barry Wallerstein, executive officer at the South Coast Air Quality Management District; Dr. John G. Watson, research professor in the Division of Atmospheric Sciences at the Desert Research Institute; Dr. George M. Hidy of Envair/Aerochem; Dr. Paul J. Lioy, Department of Environmental and Occupational Medicine; Robert Wood Johnson Medical School, University of Medicine and Dentistry, New Jersey; Dr. Herbert McKee, environmental consultant; Mr. David Mobley of the Atmospheric Modeling Division of the EPA's Office of Research and Development; and Mr. Keith Baugues, P.E., of air services for KERAMIDA Environmental. 127 refs.

  3. Testing the efficacy and the potential effect on indoor air quality of a transparent self-cleaning TiO{sub 2}-coated glass through the degradation of a fluoranthene layer

    Energy Technology Data Exchange (ETDEWEB)

    Romeas, V.; Pichat, P.; Guillard, C.; Chopin, T.; Lehaut, C.

    1999-10-01

    Self-cleaning glass can be obtained by coating glass with a transparent, thin layer of TiO{sub 2} nanoparticles. To test the self-cleaning properties, fluoranthene--the most abundant polycyclic aromatic hydrocarbon in the atmospheric particulate matter--was sprayed over the glass. Under solar-like UV light, not only was fluoranthene removed at a rate of ca. 0.73 nmol/h per cm{sup 2} of glass but also all fluoranthene degradation products were, and thus the coated-glass transparency was recovered, which did not occur with noncoated glass. The fluoranthene percentage converted to volatile carbonyl products released into ambient air was lower with than without TiO{sub 2} coating; i.e., the self-cleaning glass could have a positive influence on indoor air quality. Mechanisms are discussed to account for the main primary products among the 40 fluoranthene photocatalytic degradation intermediate products which the authors identified.

  4. Health-related external cost assessment in Europe: methodological developments from ExternE to the 2013 Clean Air Policy Package.

    Science.gov (United States)

    van der Kamp, Jonathan; Bachmann, Till M

    2015-03-03

    "Getting the prices right" through internalizing external costs is a guiding principle of environmental policy making, one recent example being the EU Clean Air Policy Package released at the end of 2013. It is supported by impact assessments, including monetary valuation of environmental and health damages. For over 20 years, related methodologies have been developed in Europe in the Externalities of Energy (ExternE) project series and follow-up activities. In this study, we aim at analyzing the main methodological developments over time from the 1990s until today with a focus on classical air pollution-induced human health damage costs. An up-to-date assessment including the latest European recommendations is also applied. Using a case from the energy sector, we identify major influencing parameters: differences in exposure modeling and related data lead to variations in damage costs of up to 21%; concerning risk assessment and monetary valuation, differences in assessing long-term exposure mortality risks together with assumptions on particle toxicity explain most of the observed changes in damage costs. These still debated influencing parameters deserve particular attention when damage costs are used to support environmental policy making.

  5. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.

    Science.gov (United States)

    Hiatt, Jessica R; Rivard, Mark J; Hughes, H Grady

    2016-03-01

    Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. ["Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source," Med. Phys. 33, 4020-4032 (2006)] and recently by Hiatt et al. ["A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model," Med. Phys. 42, 2764-2776 (2015)] with improved geometric characterization. While these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. ["New national air-kerma standard for low-energy electronic brachytherapy sources," J. Res. Natl. Inst. Stand. Technol. 119, 554-574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in airair(d=50 cm) using MC methods for the model S700 eBT source. Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. ["Comparison of exposure standards in the 10-50 kV x-ray region," Metrologia 5, 1-11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K̇air(d=50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2 π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using

  6. Biodiesel Fuel Company Owner Pleads Guilty to Fraud and Clean Air Act Crimes Connected to Renewable Fuels Scheme / Philip J. Rivkin faces more than 10 years imprisonment and $51 million in restitution

    Science.gov (United States)

    WASHINGTON - Philip Joseph Rivkin, a.k.a. Felipe Poitan Arriaga, 50, today pleaded guilty to a Clean Air Act false statement and mail fraud as part of his role in a scheme to defraud EPA by falsely representing that he was producing millions of gall

  7. 浅析某血液制品车间的洁净空调设计%Brief Analysis of Design of Cleaning Air-conditioner Used in One Blood Product Workshop

    Institute of Scientific and Technical Information of China (English)

    邓盼盼

    2015-01-01

    Based on the design of cleaning air-conditioner used in one blood product workshop, and combined with the special condition and design requirements, the principles and methods in designing cleaning air-conditioner were introduced in this article. At the same time, the notices in the design of cleaning air-conditioner and the special features in designing cleaning air-conditioner for blood products were analyzed and discussed.%以某血液制品生产车间的洁净空调设计过程为依据,结合该类药品生产的特殊情况及设计要求,介绍了洁净空调系统设计的原则及方法等问题,分析探讨了洁净空调设计时应该注意的事项以及该类药品的洁净空调设计的特殊性。

  8. Of paradise and clean power: The effect of California's renewable portfolio standard on in-state renewable energy generation

    Science.gov (United States)

    Yin, Clifton Lee

    Renewable portfolio standards (RPS), policies that encourage acquisition of electricity from renewable energy sources, have become popular instruments for discouraging the use of climate change inducing-fossil fuels. There has been limited research, however, that empirically evaluates their effectiveness. Using data gathered by three governmental entities -- the federal-level Energy Information Administration and two California agencies, the Employment Development Department and the Department of Finance -- this paper investigates the impact of California's RPS, one of the nation's most ambitious such policies, on in-state renewable energy generation. It finds that the California RPS did not bring about a one-time increase in generation with its inception, nor did it compel an increase in generation over time. These results raise questions as to the best way to structure RPS policies in light of growing interest in the establishment of a national RPS.

  9. Overview of Clean Air Title V Financial Management and Reporting: A Handbook for Financial Officers and Program Managers

    Science.gov (United States)

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  10. Policy Decisions With Regard To The Applicability Of The Clean Air Act Requirements To The Strategic Petroleum Reserve

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  11. 78 FR 7428 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Science.gov (United States)

    2013-02-01

    ... Control Technology Standard for Noranda's Industrial Boilers. On December 14, 2012, the Administrator...; certain stack tests show the NO X emissions exceed PSD thresholds, yet the Title V Permit fails to include applicable PSD requirements for NO X emissions; LDEQ failed to support its conclusion that emissions from...

  12. 77 FR 19716 - Notice of Filing of Consent Decree Pursuant to the Clean Air Act, CERCLA and EPCRA

    Science.gov (United States)

    2012-04-02

    ... New Source Performance Standards (NSPS), and Risk Management Plan regulations, and CERCLA and EPCRA... injunctive relief directed primarily at insuring future compliance with the Risk Management Program... be obtained by mail from the Consent Decree Library, P.O. Box 7611, U.S. Department of...

  13. Enabling the environmentally clean air transportation of the future: a vision of computational fluid dynamics in 2030

    Science.gov (United States)

    Slotnick, Jeffrey P.; Khodadoust, Abdollah; Alonso, Juan J.; Darmofal, David L.; Gropp, William D.; Lurie, Elizabeth A.; Mavriplis, Dimitri J.; Venkatakrishnan, Venkat

    2014-01-01

    As global air travel expands rapidly to meet demand generated by economic growth, it is essential to continue to improve the efficiency of air transportation to reduce its carbon emissions and address concerns about climate change. Future transports must be ‘cleaner’ and designed to include technologies that will continue to lower engine emissions and reduce community noise. The use of computational fluid dynamics (CFD) will be critical to enable the design of these new concepts. In general, the ability to simulate aerodynamic and reactive flows using CFD has progressed rapidly during the past several decades and has fundamentally changed the aerospace design process. Advanced simulation capabilities not only enable reductions in ground-based and flight-testing requirements, but also provide added physical insight, and enable superior designs at reduced cost and risk. In spite of considerable success, reliable use of CFD has remained confined to a small region of the operating envelope due, in part, to the inability of current methods to reliably predict turbulent, separated flows. Fortunately, the advent of much more powerful computing platforms provides an opportunity to overcome a number of these challenges. This paper summarizes the findings and recommendations from a recent NASA-funded study that provides a vision for CFD in the year 2030, including an assessment of critical technology gaps and needed development, and identifies the key CFD technology advancements that will enable the design and development of much cleaner aircraft in the future. PMID:25024413

  14. Experimental Study on Efficient Photocatalysis Air Cleaning Device%一种光触媒高效空气净化器的实验研究

    Institute of Scientific and Technical Information of China (English)

    闫其年; 刘志强; 杨景发; 张子生

    2011-01-01

    In order to achieve the purpose of efficient air purification , based on the physical method,the sketch map of cyclotron duct for diversion and syntonic light source structure were designed by using the Photocatalysis of TiO2 and the biology effect of ozone and ultraviolet. The efficient photocatalysis air cleaning cartridge which was used for poultry house has the advantage of advanced air-filtering ability, enduring and stable effect as well as wide range of application. The cartridge's efficiency of removing germ,formaldehyde and ammonia was 90.9%, 63.9% and 86.2% respectively.%为了达到高效净化空气的目的,从物理方法入手,利用二氧化钛光触媒的光催化作用、短波紫外线和臭氧的生物效应原理,通过"多波段谐振光源"和"导流回旋风道"的设计,研制出一款光触媒高效空气净化器,具有净化空气能力强、效果持久稳定、无二次公害和维持费用低、操作简便、适用范围广等优点.细菌的去除效率在90.9%以上,甲醛去除效率为63.9%,氨去除效率为86.2%.

  15. The implement of air pollution detection and clean based on the TP-4 sensor%基于TP-4传感器的空气污染检测及清理的实现

    Institute of Scientific and Technical Information of China (English)

    周凡力; 耿建平

    2012-01-01

    Aiming at indoor air pollution, a kind of effective detection and clean design scheme for cleaning indoor air and improving living environment was proposed. Degree of air pollution indoor was tested by TP-4 sensors, and sending the data to calculate by microcontroller, then the microcontroller controled the air pollution treatment to e-liminate the air pollution according to the results. The microcontroller processing method adopted PID real-time control technology to make the air clean. The technology adopted in this scheme can clean air quickly,suit to family and office environment.%针对室内空气污染,提出了一种有效的检测及清理设计方案,以达到清洁室内空气、保障生活环境的目的.采用TP-4传感器对室内空气污染程度进行检测,将检测采样结果送到单片机进行处理,由单片机根据处理结果控制空气污染处理器来消除空气中的污染.单片机处理方法则采用PID实时控制技术,使空气始终保持在清洁状态下.该方案采用的控制技术能迅速清洁空气,适用于家庭与办公环境下的空气清理.

  16. Integrating Susceptibility into Environmental Policy: An Analysis of the National Ambient Air Quality Standard for Lead

    Directory of Open Access Journals (Sweden)

    Ramya Chari

    2012-03-01

    Full Text Available Susceptibility to chemical toxins has not been adequately addressed in risk assessment methodologies. As a result, environmental policies may fail to meet their fundamental goal of protecting the public from harm. This study examines how characterization of risk may change when susceptibility is explicitly considered in policy development; in particular we examine the process used by the U.S. Environmental Protection Agency (EPA to set a National Ambient Air Quality Standard (NAAQS for lead. To determine a NAAQS, EPA estimated air lead-related decreases in child neurocognitive function through a combination of multiple data elements including concentration-response (CR functions. In this article, we present alternative scenarios for determining a lead NAAQS using CR functions developed in populations more susceptible to lead toxicity due to socioeconomic disadvantage. The use of CR functions developed in susceptible groups resulted in cognitive decrements greater than original EPA estimates. EPA’s analysis suggested that a standard level of 0.15 µg/m3 would fulfill decision criteria, but by incorporating susceptibility we found that options for the standard could reasonably be extended to lower levels. The use of data developed in susceptible populations would result in the selection of a more protective NAAQS under the same decision framework applied by EPA. Results are used to frame discussion regarding why cumulative risk assessment methodologies are needed to help inform policy development.

  17. Demonstration of Air-Power-Assist Engine Technology for Clean Combustion and Direct Energy Recovery in Heavy Duty Application

    Energy Technology Data Exchange (ETDEWEB)

    Hyungsuk Kang; Chun Tai

    2010-05-01

    The first phase of the project consists of four months of applied research, starting from September 1, 2005 and was completed by December 31, 2005. During this time, the project team heavily relied on highly detailed numerical modeling techniques to evaluate the feasibility of the APA technology. Specifically, (i) A GT-Power{sup TM}engine simulation model was constructed to predict engine efficiency at various operating conditions. Efficiency was defined based on the second-law thermodynamic availability. (ii) The engine efficiency map generated by the engine simulation was then fed into a simplified vehicle model, which was constructed in the Matlab/Simulink environment, to predict fuel consumption of a refuse truck on a simple collection cycle. (iii) Design and analysis work supporting the concept of retrofitting an existing Sturman Industries Hydraulic Valve Actuation (HVA) system with the modifications that are required to run the HVA system with Air Power Assist functionality. A Matlab/Simulink model was used to calculate the dynamic response of the HVA system. Computer aided design (CAD) was done in Solidworks for mechanical design and hydraulic layout. At the end of Phase I, 11% fuel economy improvement was predicted. During Phase II, the engine simulation group completed the engine mapping work. The air handling group made substantial progress in identifying suppliers and conducting 3D modelling design. Sturman Industries completed design modification of the HVA system, which was reviewed and accepted by Volvo Powertrain. In Phase II, the possibility of 15% fuel economy improvement was shown with new EGR cooler design by reducing EGR cooler outlet temperature with APA engine technology from Air Handling Group. In addition, Vehicle Simulation with APA technology estimated 4 -21% fuel economy improvement over a wide range of driving cycles. During Phase III, the engine experimental setup was initiated at VPTNA, Hagerstown, MD. Air Handling system and HVA

  18. Finding of No Significant Impact: Replacement of Chemical Cleaning Line Tinker Air Force Base Oklahoma City, Oklahoma

    Science.gov (United States)

    2012-05-01

    Alternative Site Locations Page 2-4 February 2012 0 Gl• Locer.on -....--....... c:::::J Tlnh• N’B -ry N A LANCER GATE UBERATOR GATE Environmental... Economy standards. 3.1.2.4 Proposed Project Location Building 3001 is located on the eastern portion of Tinker AFB and is identified as the largest...to the economy of Oklahoma City. According to the Greater Oklahoma City Chamber of Commerce (2010), the top five employers in the Oklahoma City

  19. Development, characterization, and validation of an optical transfer standard for ammonia in air

    Science.gov (United States)

    Lüttschwager, Nils; Balslev-Harder, David; Leuenberger, Daiana; Pogány, Andrea; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Ammonia is an atmospheric trace gas that is predominantly emitted from anthropogenic agricultural activities. Since elevated levels of ammonia can have negative effects to human health as well as ecosystems, it is imperative to monitor and control ammonia emissions. This requires SI-traceable standards to calibrate ammonia monitoring instrumentation and to make measurements comparable. The lack of such standards became a pressing issue in recent years and the MetNH3 project (www.metnh3.eu) was initiated to fill the gap, pursuing different strategies. The work that we present was part of these endeavours and focusses on the development and application of an optical transfer standard for amount fraction measurements of ammonia in ambient air. An optical transfer standard (OTS) offers an alternative to calibrations of air monitoring instrumentation by means of reference gas mixtures. With an OTS, absolute amount fraction results are derived by evaluating absorption spectra using a spectral model and pre-measured spectral properties of the analyte. In that way, the instrument can measure calibration gas-independent ("calibration-free") and, moreover, can itself serve as standard to calibrate air monitoring analyzers. Molecular spectral properties are the excellent, non-drifting point of reference of the OTS and form, together with traceable measurements of temperature and pressure, the basis for SI-traceable amount fraction measurements. We developed an OTS based on a commercial cavity-ring-down spectrometer with a detection limit below 1 ppb (1 nmol/mol). A custom spectral data evaluation routine for absolute, calibration-free measurements, as well as measurements of spectral properties of ammonia with the focus on measurement uncertainty and traceability [1] are the fundaments of our OTS. Validation measurements were conducted using a SI-traceable ammonia reference gas generator over a period of several months. Here, we present an evaluation of the performance of our

  20. Air quality standards for the protection of farm animals from fluorides

    Energy Technology Data Exchange (ETDEWEB)

    Suttie, J.W.

    1969-04-01

    The ingestion of forages contaminated with inorganic fluorides from industrial sources constitutes an air pollution problem for domestic livestock. In cattle, which have been studied most extensively, the syndrome is characterized by dental and skeletal lesions, lameness, chemical evidence of increased fluoride ingestion, and in severe cases by effects on appetite and milk production. The only practical basis for a standard appears to be one based on forage fluoride concentrations. It is concluded that a standard should protect cattle from loss of milk production and from severe dental fluorosis, but need not be set so low that the animals will be protected against any discernible deviations from normal which do not influence their general health, productive ability, or the soundness and wearing quality of their dentition. As there may be wide seasonal variations in forage fluoride concentrations, the basic standard should be expressed as a yearly average of the forage fluoride concentration. However, as the developing teeth may be adversely influenced by short periods of high exposure, the standard should contain a provision which limits both the extent and duration of time that high concentrations may be tolerated even though they are balanced by lower values at other months. Based on these criteria, a tentative standard which limits forage fluoride to an average of 40 ppm, and limits the time that forage concentrations may exceed 60 to 80 ppm F is proposed.

  1. 电子工业厂房洁净空调系统施工监理的控制要点%On controlling points for construction inspection for cleaning air-conditioner system of electronic industrial workshops

    Institute of Scientific and Technical Information of China (English)

    吕坤

    2015-01-01

    Combining with engineering cases,the paper analyzes the features of cleaning air-conditioner system of electronic industrial workshops, and illustrates the monitoring controlling points for the cleaning air-conditioner system of electronic industrial workshops from the materials and equipment entry,installation of air-conditioner wind system and air-conditioner water system,so as to enhance the cleaning air-conditioner system to achieve the expected effect.%结合工程案例,分析了电子工业洁净空调系统的特点,并从材料和设备进场、空调风系统安装、空调水系统安装三个方面出发,阐述了电子工业厂房洁净空调系统施工的监理控制要点,促使洁净空调系统达到预期的效果。

  2. Designations in US EPA Region 9 for the 1997 8-hour ozone (O3) national ambient air quality standards

    Data.gov (United States)

    U.S. Environmental Protection Agency — Polygon Esri shapefile of designated areas for 8-hour ozone, for the revoked primary and secondary 1997 National Ambient Air Quality Standards (NAAQS). Nonattainment...

  3. EPA Finalizes Initial Area Designations for the 2012 National Air Quality Standard for Fine Particles - Dec 2014

    Science.gov (United States)

    After considering state and tribal recommendations, reviewing the most recent certified fine particle air quality data, and emissions that contribute fine particle pollution, EPA has completed initial designations for the 2012 annual fine particle standard

  4. Final Air Toxics Standards for Clay Ceramics Manufacturing, Glass Manufacturing, and Secondary Nonferrous Metals Processing Area Sources Fact Sheet

    Science.gov (United States)

    This page contains a December 2007 fact sheet with information regarding the National Emissions Standards for Hazardous Air Pollutants (NESHAP) for Clay Ceramics Manufacturing, Glass Manufacturing, and Secondary Nonferrous Metals Processing Area Sources

  5. Hospital ventilation standards and energy conservation: chemical contamination of hospital air. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rainer, D.; Michaelsen, G.S.

    1980-03-01

    In an era of increasing energy conservation consciousness, a critical reassessment of the validity of hospital ventilation and thermal standards is made. If current standards are found to be excessively conservative, major energy conservation measures could be undertaken by rebalancing and/or modification of current HVAC systems. To establish whether or not reducing ventilation rates would increase airborne chemical contamination to unacceptable levels, a field survey was conducted to develop an inventory and dosage estimates of hospital generated airborne chemical contaminants to which patients, staff, and visitors are exposed. The results of the study are presented. Emphasis is on patient exposure, but an examination of occupational exposure was also made. An in-depth assessment of the laboratory air environment is documented. Housekeeping products used in survey hospitals, hazardous properties of housekeeping chemicals and probable product composition are discussed in the appendices.

  6. 76 FR 72241 - Fourteenth Meeting: RTCA Special Committee 214/EUROCAE WG-78: Standards for Air Traffic Data...

    Science.gov (United States)

    2011-11-22

    ... for Air Traffic Data Communication Services AGENCY: Federal Aviation Administration (FAA), U.S... Traffic Data Communication Services meeting. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 214/EUROCAE WG-78: Standards for Air Traffic Data...

  7. 75 FR 39252 - Release of Final Documents Related to the Review of the National Ambient Air Quality Standards...

    Science.gov (United States)

    2010-07-08

    ... ``cause or contribute to air pollution which may reasonably be anticipated to endanger public health or... Pekar, Office of Air Quality Planning and Standards (Mail code C504-06), U.S. Environmental Protection... scientific knowledge useful in indicating the kind and extent of all identifiable effects on public health...

  8. 77 FR 35285 - Approval of Air Quality Implementation Plan; Arizona; Attainment Plan for 1997 8-Hour Ozone Standard

    Science.gov (United States)

    2012-06-13

    ... AGENCY 40 CFR 52 Approval of Air Quality Implementation Plan; Arizona; Attainment Plan for 1997 8-Hour... approving a state implementation plan (SIP) revision submitted by the State of Arizona on June 13, 2007, to demonstrate attainment of the 1997 8-hour ozone national ambient air quality standards (NAAQS) in the Phoenix...

  9. Study on an Air Quality Evaluation Model for Beijing City Under Haze-Fog Pollution Based on New Ambient Air Quality Standards

    Science.gov (United States)

    Li, Li; Liu, Dong-Jun

    2014-01-01

    Since 2012, China has been facing haze-fog weather conditions, and haze-fog pollution and PM2.5 have become hot topics. It is very necessary to evaluate and analyze the ecological status of the air environment of China, which is of great significance for environmental protection measures. In this study the current situation of haze-fog pollution in China was analyzed first, and the new Ambient Air Quality Standards were introduced. For the issue of air quality evaluation, a comprehensive evaluation model based on an entropy weighting method and nearest neighbor method was developed. The entropy weighting method was used to determine the weights of indicators, and the nearest neighbor method was utilized to evaluate the air quality levels. Then the comprehensive evaluation model was applied into the practical evaluation problems of air quality in Beijing to analyze the haze-fog pollution. Two simulation experiments were implemented in this study. One experiment included the indicator of PM2.5 and was carried out based on the new Ambient Air Quality Standards (GB 3095-2012); the other experiment excluded PM2.5 and was carried out based on the old Ambient Air Quality Standards (GB 3095-1996). Their results were compared, and the simulation results showed that PM2.5 was an important indicator for air quality and the evaluation results of the new Air Quality Standards were more scientific than the old ones. The haze-fog pollution situation in Beijing City was also analyzed based on these results, and the corresponding management measures were suggested. PMID:25170682

  10. Study on an air quality evaluation model for Beijing City under haze-fog pollution based on new ambient air quality standards.

    Science.gov (United States)

    Li, Li; Liu, Dong-Jun

    2014-08-28

    Since 2012, China has been facing haze-fog weather conditions, and haze-fog pollution and PM2.5 have become hot topics. It is very necessary to evaluate and analyze the ecological status of the air environment of China, which is of great significance for environmental protection measures. In this study the current situation of haze-fog pollution in China was analyzed first, and the new Ambient Air Quality Standards were introduced. For the issue of air quality evaluation, a comprehensive evaluation model based on an entropy weighting method and nearest neighbor method was developed. The entropy weighting method was used to determine the weights of indicators, and the nearest neighbor method was utilized to evaluate the air quality levels. Then the comprehensive evaluation model was applied into the practical evaluation problems of air quality in Beijing to analyze the haze-fog pollution. Two simulation experiments were implemented in this study. One experiment included the indicator of PM2.5 and was carried out based on the new Ambient Air Quality Standards (GB 3095-2012); the other experiment excluded PM2.5 and was carried out based on the old Ambient Air Quality Standards (GB 3095-1996). Their results were compared, and the simulation results showed that PM2.5 was an important indicator for air quality and the evaluation results of the new Air Quality Standards were more scientific than the old ones. The haze-fog pollution situation in Beijing City was also analyzed based on these results, and the corresponding management measures were suggested.

  11. Quantitative Evaluation of Contamination on Dental Zirconia Ceramic by Silicone Disclosing Agents after Different Cleaning Procedures

    Directory of Open Access Journals (Sweden)

    Sebastian Wille

    2015-05-01

    Full Text Available The aim of this study was to evaluate the effectiveness of cleaning procedures for air-abraded zirconia after contamination with two silicone disclosing agents. Air-abraded zirconia ceramic specimens (IPS e.max ZirCAD were contaminated with either GC Fit Checker white or GC Fit Checker II. Untreated zirconia specimens were used as control. Afterwards the surfaces were cleaned either with waterspray or ultrasonically in 99% isopropanol or using a newly developed cleaning paste (Ivoclean. After cleaning X-ray photoelectron spectroscopy (XPS was performed and the relative peak intensities of Zr, C and Si were used for a qualitative comparison of the residuals. There was no significant difference between the two different silicone disclosing agents. An additional cleaning step with isopropanol led to a significantly lower amount of residuals on the surface, but an additional cleaning process with Ivoclean did not reduce the amount of carbon residuals in comparison to the isopropanol cleaning. Just the silicone amount on the surface was reduced. None of the investigated cleaning processes removed all residuals from the contaminated surface. Standard cleaning processes do not remove all residuals of the silicone disclosing agent from the surface. This may lead to a failure of the resin-ceramic bonding.

  12. 7 CFR 51.606 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.606 Section 51.606 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Consumer Standards for Celery Stalks Definitions § 51.606 Clean. Clean means that the stalk is...

  13. 7 CFR 51.1553 - Fairly clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly clean. 51.1553 Section 51.1553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades of Potatoes 1 Definitions § 51.1553 Fairly clean. Fairly clean means that at least...

  14. 7 CFR 51.1581 - Fairly clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly clean. 51.1581 Section 51.1581 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Consumer Standards for Potatoes Definitions § 51.1581 Fairly clean. Fairly clean means that from...

  15. 7 CFR 51.1316 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.1316 Section 51.1316 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Winter Pears 1 Definitions § 51.1316 Clean. Clean means free from excessive dirt, dust,...

  16. 7 CFR 29.2256 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 29.2256 Section 29.2256 Agriculture Regulations... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2256 Clean. Tobacco is described as clean when it contains only a normal amount of sand or soil particles....

  17. 7 CFR 51.1552 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.1552 Section 51.1552 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades of Potatoes 1 Definitions § 51.1552 Clean. Clean means that at least 90 percent of...

  18. 7 CFR 51.2288 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.2288 Section 51.2288 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Shelled English Walnuts (Juglans Regia) Definitions § 51.2288 Clean. Clean means that...

  19. 7 CFR 51.1867 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.1867 Section 51.1867 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Fresh Tomatoes 1 Definitions § 51.1867 Clean. Clean means that the tomato is practically...

  20. 7 CFR 51.2965 - Fairly clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Fairly clean. 51.2965 Section 51.2965 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades of Walnuts in the Shell Definitions § 51.2965 Fairly clean. Fairly clean means...

  1. 7 CFR 51.2654 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.2654 Section 51.2654 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades for Sweet Cherries 1 Definitions § 51.2654 Clean. Clean means that the cherries...

  2. 7 CFR 51.2083 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.2083 Section 51.2083 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades of Almonds in the Shell Definitions § 51.2083 Clean. Clean means that the shell...

  3. 7 CFR 51.2118 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.2118 Section 51.2118 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Grades of Shelled Almonds Definitions § 51.2118 Clean. Clean means that the kernel...

  4. 7 CFR 51.3061 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.3061 Section 51.3061 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Florida Avocados Definitions § 51.3061 Clean. Clean means that the avocado is practically...

  5. 7 CFR 51.1275 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.1275 Section 51.1275 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Summer and Fall Pears 1 Definitions § 51.1275 Clean. Clean means free from excessive...

  6. 7 CFR 51.570 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 51.570 Section 51.570 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Standards for Celery Definitions § 51.570 Clean. Clean means that the stalk is practically free from dirt...

  7. 7 CFR 29.6007 - Clean.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Clean. 29.6007 Section 29.6007 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6007 Clean. Tobacco is described as clean when it contains only...

  8. 40 CFR Appendix T to Part 50 - Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Sulfur (Sulfur...

    Science.gov (United States)

    2010-07-01

    ... Ambient Air Quality Standards for Oxides of Sulfur (Sulfur Dioxide) T Appendix T to Part 50 Protection of... AIR QUALITY STANDARDS Pt. 50, App. T Appendix T to Part 50—Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Sulfur (Sulfur Dioxide) 1. General (a) This appendix...

  9. EIA's role in the analysis of the Clean Air Act Amendments of 1990 and the development of the National Allowance Database

    Energy Technology Data Exchange (ETDEWEB)

    Beamon, J.A.; Linders, M.J. (Energy Information Administration, Washington, DC (United States))

    1993-01-01

    Throughout 1990 the Energy Information Administration (EIA) provided continuous data and analytic support to Congress during its deliberations on Title IV of the Clean Air Act Amendments of 1990 (CAA). Congress requested the Energy Information Administration (EIA) to review and analyze the sections that would affect electric utilities, specifically those relating to acid deposition (Title IV). By providing knowledgeable and impartial analysis, EIA clarified the likely effects of the various legislative proposals and helped Congress finalize the amendments. Even though the CAA is now law, EIA's efforts have not ended. During the analysis of the various proposals, EIA and EPA created a National Allowance Database (NAD). Now, under an agreement with the Environmental Protection Agency (EPA), a new version of the NAD is being developed to facilitate the implementation of the acid deposition provisions of the CAA. This article describes the analyses undertaken, points out where EIA's efforts led to improved understanding of the likely impacts of the CAA, and outlines EIA's continued efforts to assist EPA in the implementation of the amendments. 6 tabs.

  10. Floatable, Self-Cleaning, and Carbon-Black-Based Superhydrophobic Gauze for the Solar Evaporation Enhancement at the Air-Water Interface.

    Science.gov (United States)

    Liu, Yiming; Chen, Jingwei; Guo, Dawei; Cao, Moyuan; Jiang, Lei

    2015-06-24

    Efficient solar evaporation plays an indispensable role in nature as well as the industry process. However, the traditional evaporation process depends on the total temperature increase of bulk water. Recently, localized heating at the air-water interface has been demonstrated as a potential strategy for the improvement of solar evaporation. Here, we show that the carbon-black-based superhydrophobic gauze was able to float on the surface of water and selectively heat the surface water under irradiation, resulting in an enhanced evaporation rate. The fabrication process of the superhydrophobic black gauze was low-cost, scalable, and easy-to-prepare. Control experiments were conducted under different light intensities, and the results proved that the floating black gauze achieved an evaporation rate 2-3 times higher than that of the traditional process. A higher temperature of the surface water was observed in the floating gauze group, revealing a main reason for the evaporation enhancement. Furthermore, the self-cleaning ability of the superhydrophobic black gauze enabled a convenient recycling and reusing process toward practical application. The present material may open a new avenue for application of the superhydrophobic substrate and meet extensive requirements in the fields related to solar evaporation.

  11. Who is afraid of smoking bans? An evaluation of the effects of the Spanish clean air law on expenditure at hospitality venues.

    Science.gov (United States)

    García-Villar, Jaume; López-Nicolás, Ángel

    2015-11-01

    In January 2011 Spain modified clean air legislation in force since 2006, removing all existing exceptions applicable to hospitality venues. Although this legal reform was backed by all political parties with parliamentary representation, the government's initiative was contested by the tobacco industry and its allies in the hospitality industry. One of the most voiced arguments against the reform was its potentially disruptive effect on the revenue of hospitality venues. This paper evaluates the impact of this reform on household expenditure at restaurants and bars and cafeterias. We used household expenditure micro-data for years 2006-2012 to estimate models for the probability of observing expenditures and the expected level of expenditure. We applied a before-after analysis with a wide range of controls for confounding factors and a flexible modeling of time effects in order to identify the effects of the reform. Our results suggest that the reform caused a 2% reduction in the proportion of households containing smokers but did not cause reductions in households' expenditures on restaurant services or on bars and cafeteria services.

  12. On the way towards clean air. Plan to improve the air quality of the Zuidvleugel area, Netherlands; Op weg naar schone lucht. Plan van Aanpak Luchtkwaliteit Zuidvleugel

    Energy Technology Data Exchange (ETDEWEB)

    Janse, P.; Klooster, J.P.G.N.

    2006-01-15

    An overview is given of measures to be taken to improve the air quality in the area Zuidvleugel of western urban area in the Netherlands ('Randstad'), including an estimation of costs to implement and realize the measures in a short term. [Dutch] In de Zuidvleugel van de Randstad is de lucht vervuild. De luchtkwaliteit voldoet niet aan de Europese normen voor de stoffen stikstofdioxide (NO2) en fijn stof (PM10). Verbetering van de luchtkwaliteit staat daarom hoog op de agenda van de rijksoverheid en bestuurders in de Zuidvleugel. In opdracht van de Provincie Zuid-Holland heeft CE een inventarisatie, beoordeling en kostenraming gemaakt van maatregelen om de luchtkwaliteit te verbeteren. Vervolgens heeft CE een voorstel geformuleerd voor een effectief maatregelpakket, dat in beginsel op korte termijn kan worden uitgevoerd. Bij het samenstellen van het maatregelpakket is rekening gehouden met: effect op luchtkwaliteit (in termen van concentraties); kosteneffectiviteit; uitvoerbaarheid (maatschappelijk draagvlak/honing en azijn); termijn waarop gestart kan worden met uitvoering. In het rapport zijn de hoofdlijnen opgenomen van het pakket van maatregelen in de Zuidvleugel en een indicatie van de kosten in de periode 2006-2010.

  13. Fate and aqueous transport of mercury in light of the Clean Air Mercury Rule for coal-fired electric power plants

    Science.gov (United States)

    Arzuman, Anry

    Mercury is a hazardous air pollutant emitted to the atmosphere in large amounts. Mercury emissions from electric power generation sources were estimated to be 48 metric tons/year, constituting the single largest anthropogenic source of mercury in the U.S. Settled mercury species are highly toxic contaminants of the environment. The newly issued Federal Clean Air Mercury Rule requires that the electric power plants firing coal meet the new Maximum Achievable Mercury Control Technology limit by 2018. This signifies that all of the air-phase mercury will be concentrated in solid phase which, based on the current state of the Air Pollution Control Technology, will be fly ash. Fly ash is utilized by different industries including construction industry in concrete, its products, road bases, structural fills, monifills, for solidification, stabilization, etc. Since the increase in coal combustion in the U.S. (1.6 percent/year) is much higher than the fly ash demand, large amounts of fly ash containing mercury and other trace elements are expected to accumulate in the next decades. The amount of mercury transferred from one phase to another is not a linear function of coal combustion or ash production, depends on the future states of technology, and is unknown. The amount of aqueous mercury as a function of the future removal, mercury speciation, and coal and aquifer characteristics is also unknown. This paper makes a first attempt to relate mercury concentrations in coal, flue gas, fly ash, and fly ash leachate using a single algorithm. Mercury concentrations in all phases were examined and phase transformation algorithms were derived in a form suitable for probabilistic analyses. Such important parameters used in the transformation algorithms as Soil Cation Exchange Capacity for mercury, soil mercury selectivity sequence, mercury activity coefficient, mercury retardation factor, mercury species soil adsorption ratio, and mercury Freundlich soil adsorption isotherm

  14. 40 CFR Appendix P to Part 50 - Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone P Appendix P to Part 50 Protection of Environment... STANDARDS Pt. 50, App. P Appendix P to Part 50—Interpretation of the Primary and Secondary National...

  15. 77 FR 9303 - National Emission Standards for Hazardous Air Pollutants From Coal- and Oil-Fired Electric...

    Science.gov (United States)

    2012-02-16

    ..., for example, biomass co-fired EGUs because their use is not yet commonplace, we believe this... Standards for Hazardous Air Pollutants From Coal- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial- Commercial-Institutional,...

  16. Evaluation of air cleanness degree of the urban environment based on negative air ion concentration%基于空气负离子浓度的城市环境空气清洁度评价

    Institute of Scientific and Technical Information of China (English)

    王薇; 余庄; 冀凤全

    2013-01-01

    .Based on the measurement and research of indoor and outdoor of urban environments, air quality was assessed using ion polarity ratio and air ion assessment index (CI). The results show that air cleanness degree increases gradually from urban indoor environment to urban residential environment to country and natural environment. In urban residential environment, the air quality of low high-density residential environment is the best, the NAI concentration reaches to 289 N/cm3 at average value, and its air quality reaches to 1.7 for the cleanest; but high-level residential environment is the worst, the air quality of low high-density residential environment is the best, the NAI concentration reaches to 139 N/cm3 at average value, and its air quality reaches to 0.08 for threshold, maybe heavy pollution. In urban indoor environments, the air quality with natural ventilation and fresh air into the room is the best, and placed the negative ion generator has improved indoor air quality significantly. So the article suggests taking effective measures to increase the distribution of NAI concentration in urban planning and construction in order to improve the urban ecological environment to create a comfortable air environment, and taking the negative air ion concentration as a monitoring and evaluation indicators of the indoor environment, so as to provide a scientific basis and design concept for urban planning and construction, urban forestry planning, energy planning and environmental protection in the future.

  17. Inter-laboratory comparison study on measuring semi-volatile organic chemicals in standards and air samples.

    Science.gov (United States)

    Su, Yushan; Hung, Hayley

    2010-11-01

    Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences.

  18. Appalachian clean coal technology consortium

    Energy Technology Data Exchange (ETDEWEB)

    Kutz, K.; Yoon, Roe-Hoan [Virginia Polytechnic Institute and State Univ., Blacksburg, VA (United States)

    1995-11-01

    The Appalachian Clean Coal Technology Consortium (ACCTC) has been established to help U.S. coal producers, particularly those in the Appalachian region, increase the production of lower-sulfur coal. The cooperative research conducted as part of the consortium activities will help utilities meet the emissions standards established by the 1990 Clean Air Act Amendments, enhance the competitiveness of U.S. coals in the world market, create jobs in economically-depressed coal producing regions, and reduce U.S. dependence on foreign energy supplies. The research activities will be conducted in cooperation with coal companies, equipment manufacturers, and A&E firms working in the Appalachian coal fields. This approach is consistent with President Clinton`s initiative in establishing Regional Technology Alliances to meet regional needs through technology development in cooperation with industry. The consortium activities are complementary to the High-Efficiency Preparation program of the Pittsburgh Energy Technology Center, but are broader in scope as they are inclusive of technology developments for both near-term and long-term applications, technology transfer, and training a highly-skilled work force.

  19. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs.

  20. Information draft on the development of air standards for isopropyl benzene

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    Isopropyl benzene, also commonly referred to as cumene, is a colourless liquid with a sharp, penetrating odour. It is derived from the distillation of coal tar, naphtha and petroleum. It is used mainly as an intermediate in the production of phenol, acetone, and alpha-methyl styrene, all of which are components in plastic resins. Isopropyl benzene is also used as a solvent and thinner for paints and enamels and as an octane booster in aviation gasoline. In 1996, reported atmospheric releases in Canada amounted to 16.4 tonnes, of which 9.1 tonnes were from Ontario sources. Isopropyl benzene is not a significant threat to health in low concentrations. Inhalation exposure can cause dizziness, light-headedness and fainting. Contact with isopropyl benzene can irritate the skin, eyes, nose and mouth. The current Ontario half-hour interim Point of Impingement (OPI) standard and the one-hour Ambient Air Quality Criterion (AAQC) are both set at 100 microgram/cubic meter on the basis of the odour nuisance property of the substance. A review of applicable literature from world-wide sources (and summarized in this report) reveal that four US agencies have developed air quality criteria for isopropyl benzene based on the health effects of the compound. These criteria range from 9 to 585 micrograms/cubic meter for an annual average basis and from 87 to 400 microgram/cubic meter on a 24-hour basis. 40 refs., 1 tab., appendix.