  1. Surface Modifications of Polymeric Materials for Application in Artificial Heart and Circulatory Assist Devices

    NARCIS (Netherlands)

    Feijen, J.; Engbers, G.H.M.; Terlingen, J.G.A.; van Delden, C.J.; Poot, A.A.; Vaudaux, P.; Akutsu, Tetsuzo; Koyanagi, Hitoshi

    1996-01-01

    Several methods have been developed to modify the surfaces of materials used in artificial hearts and circulatory assist devices to suppress the host response, especially with respect to the occurrence of clotting, cellular damage, and infections. In this review, special attention is paid to

  2. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  3. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  4. [Mechanical circulatory support saves lives -- three years' experience of the newly established assist device program at Semmelweis University, Budapest, Hungary].

    Science.gov (United States)

    Fazekas, Levente; Sax, Balázs; Hartyánszky, István; Pólos, Miklós; Horkay, Ferenc; Varga, Tamás; Rácz, Kristóf; Németh, Endre; Székely, Andrea; Paulovich, Erzsébet; Heltai, Krisztina; Zima, Endre; Szabolcs, Zoltán; Merkely, Béla

    2015-03-29

    Since the celebration of the 20th anniversary of the first heart transplantation in Hungary in 2012 the emerging need for modern heart failure management via mechanical circulatory support has evolved. In May 2012 the opening of a new heart failure and transplant unit with 9 beds together with the procurement of necessary devices at Semmelweis University accomplished this need. The aim of the authors was to report their initial experience obtained in this new cardiac assist device program. Since May, 2012, mechanical circulatory support system was applied in 89 cases in 72 patients. Indication for support were end stage heart failure refractory to medical treatment and acute left or right heart failure. Treatment was initiated for acute graft failure after heart transplantation in 27 cases, for end stage heart failure in 24 cases, for acute myocardial infarction in 21 cases, for acute postcardiotomy heart failure in 14 cases, for severe respiratory insufficiency in 2 cases and for drug intoxication in one case. Among the 30 survivor of the whole program 13 patients were successfully transplanted. The available devices can cover all modalities of current bridge therapy from short term support through medium support to heart transplantation or long term support and destination therapy. These conditions made possible the successful start of a new cardiac assist device program.

  5. Mechanical circulatory assist device development at the Texas Heart Institute: a personal perspective.

    Science.gov (United States)

    Frazier, O H

    2014-01-01

    In December 2013, we performed our 1000th ventricular assist device implantation at the Texas Heart Institute. In my professional career, I have been fortunate to see the development of numerous mechanical circulatory support devices for the treatment of patients with advanced heart failure. In fact, most of the cardiac pumps in wide use today were developed in the Texas Heart Institute research laboratories in cooperation with the National Heart, Lung and Blood Institute or device innovators and manufacturers and implanted clinically at our partner St. Luke's Episcopal Hospital. My early involvement in this field was guided by my mentors, Dr Michael E. DeBakey and, especially, Dr Denton A. Cooley. Also, many of the advances are directly attributable to my ongoing clinical experience. What I learned daily in my surgical practice allowed me to bring insights to the development of this technology that a laboratory researcher alone might not have had. Young academic surgeons interested in this field might be well served to be active not only in laboratory research but also in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  7. Energy transmission and power sources for mechanical circulatory support devices to achieve total implantability.

    Science.gov (United States)

    Wang, Jake X; Smith, Joshua R; Bonde, Pramod

    2014-04-01

    Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    Science.gov (United States)

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  9. New Innovations in Circulatory Support With Ventricular Assist Device and Extracorporeal Membrane Oxygenation Therapy.

    Science.gov (United States)

    Sladen, Robert N

    2017-04-01

    The past decade has seen an exponential increase in the application and development of durable long-term as well as nondurable short-term mechanical circulatory support for cardiogenic shock and acute or chronic heart failure. Support has evolved from bridge-to-transplant to destination therapy, bridge to rescue, bridge to decision making, and bridge to a bridge. Notable trends include device miniaturization, minimally invasive and/or percutaneous insertion, and efforts to superimpose pulsatility on continuous flow. We can certainly anticipate that innovation will accelerate in the months and years to come. However, despite-or perhaps because of-the enhanced equipment now available, mechanical circulatory support is an expensive, complex, resource-intensive modality. It requires considerable expertise that should preferably be centralized to highly specialized centers. Formidable challenges remain: systemic inflammatory response syndromes and vasoplegia after device insertion; postoperative sepsis; optimal anticoagulation regimens to prevent device-induced thrombosis and cerebral thromboembolism; wound site, intracranial, and gastrointestinal bleeding; multisystem injury and failure; patient dissatisfaction (even when providers consider the procedure a "success"); and ethical decision making in conditions of futility.

  10. A microfluidic circulatory system integrated with capillary-assisted pressure sensors.

    Science.gov (United States)

    Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai

    2017-02-14

    The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.

  11. COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

    NARCIS (Netherlands)

    Neyt, Mattias; Van den Bruel, Ann; Smit, Yolba; De Jonge, Nicolaas; Erasmus, Michiel; Van Dijk, Diederik; Vlayen, Joan

    Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs.

  12. Development of mechanical circulatory support devices in China.

    Science.gov (United States)

    Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang

    2009-11-01

    Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.

  13. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  14. Mechanical circulatory support in pediatrics.

    Science.gov (United States)

    Steffen, Robert J; Miletic, Kyle G; Schraufnagel, Dean P; Vargo, Patrick R; Fukamachi, Kiyotaka; Stewart, Robert D; Moazami, Nader

    2016-05-01

    End-stage heart failure affects thousands of children yearly and mechanical circulatory support is used at many points in their care. Extracorporeal membrane oxygenation supports both the failing heart and lungs, which has led to its use as an adjunct to cardiopulmonary resuscitation as well as in post-operative cardiogenic shock. Continuous-flow ventricular assist devices (VAD) have replaced pulsatile-flow devices in adults and early studies have shown promising results in children. The Berlin paracorporeal pulsatile VAD recently gained U.S. Food and Drug Administration approval and remains the only VAD approved in pediatrics. Failing univentricular hearts and other congenitally corrected lesions are new areas for mechanical support. Finding novel uses, improving durability, and minimizing complications are areas of growth in pediatric mechanical circulatory support.

  15. Ethical challenges with the left ventricular assist device as a destination therapy

    Directory of Open Access Journals (Sweden)

    Rady Mohamed Y

    2008-08-01

    Full Text Available Abstract The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1 direct participation of a multidisciplinary care team, including palliative care specialists, (2 a concise plan of care for anticipated device-related complications, (3 careful surveillance and counseling for caregiver burden, (4 advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5 a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e

  16. Outcomes of pediatric patients supported with continuous-flow ventricular assist devices: A report from the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).

    Science.gov (United States)

    Rossano, Joseph W; Lorts, Angela; VanderPluym, Christina J; Jeewa, Aamir; Guleserian, Kristine J; Bleiweis, Mark S; Reinhartz, Olaf; Blume, Elizabeth D; Rosenthal, David N; Naftel, David C; Cantor, Ryan S; Kirklin, James K

    2016-05-01

    Continuous-flow (CF) ventricular assist devices (VADs) have largely replaced pulsatile-flow VADs in adult patients. However, there are few data on CF VADs among pediatric patients. In this study we aimed to describe the overall use, patients' characteristics and outcomes of CF VADs in this population. The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a national registry for U.S. Food and Drug Adminstration (FDA)-approved VADs in patients <19 years of age. Patients undergoing placement of durable CF VADs between September 2012 and June 2015 were included and outcomes were compared with those of adults from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). CF VADs were implanted in 109 patients at 35 hospitals. The median age at implantation was 15 years (2.8 to 18.9 years) and median weight was 62 kg (range 16 to 141 kg). The underlying disease was cardiomyopathy in 89 (82%) patients. The INTERMACS level at time of implant was Level 1 in 20 (19%), Level 2 in 64 (61%) and Levels 3 to 7 in 21 (20%) patients. Most were implanted as LVADs (n = 102, 94%). Median duration of support was 2.3 months (range <1 day to 28 months). Serious adverse event rates were low, including neurologic dysfunction (early event rate 4.1 per 100 patient-months with 2 late events). Competing outcomes analysis at 6 months post-implant indicated 61% transplanted, 31% alive with device in place and 8% death before transplant. These outcomes compared favorably with the 3,894 adults supported with CF VADs as a bridge to transplant. CF VADs are commonly utilized in older children and adolescents, with excellent survival rates. Further study is needed to understand impact of patient and device characteristics on outcomes in pediatric patients. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  17. Designs for mechanical circulatory support device studies.

    Science.gov (United States)

    Neaton, James D; Normand, Sharon-Lise; Gelijns, Annetine; Starling, Randall C; Mann, Douglas L; Konstam, Marvin A

    2007-02-01

    There is increased interest in mechanical circulatory support devices (MCSDs), such as implantable left ventricular assist devices (LVADs), as "destination" therapy for patients with advanced heart failure. Because patient availability to evaluate these devices is limited and randomized trials have been slow in enrolling patients, a workshop was convened to consider designs for MCSD development including alternatives to randomized trials. A workshop was jointly planned by the Heart Failure Society of America and the US Food and Drug Administration and was convened in March 2006. One of the panels was asked to review different designs for evaluating new MCSDs. Randomized trials have many advantages over studies with no controls or with nonrandomized concurrent or historical controls. These advantages include the elimination of bias in the assignment of treatments and the balancing, on average, of known and unknown baseline covariates that influence response. These advantages of randomization are particularly important for studies in which the treatments may not differ from one another by a large amount (eg, a head-to-head study of an approved LVAD with a new LVAD). However, researchers have found it difficult to recruit patients to randomized studies because the number of clinical sites that can carry out the studies is not large. Also, there is a reluctance to randomize patients when the control device is considered technologically inferior. Thus ways of improving the design of randomized trials were discussed, and the advantages and disadvantages of alternative designs were considered. The panel concluded that designs should include a randomized component. Randomized designs might be improved by allowing the control device to be chosen before randomization, by first conducting smaller vanguard studies, and by allowing crossovers in trials with optimal medical management controls. With use of data from completed trials, other databases, and registries, alternative

  18. The medical physics of ventricular assist devices

    International Nuclear Information System (INIS)

    Wood, Houston G; Throckmorton, Amy L; Untaroiu, Alexandrina; Song Xinwei

    2005-01-01

    Millions of patients, from infants to adults, are diagnosed with congestive heart failure each year all over the world. A limited number of donor hearts available for these patients results in a tremendous demand for alternative, supplemental circulatory support in the form of artificial heart pumps or ventricular assist devices (VADs). The development procedure for such a device requires careful consideration of biophysical factors, such as biocompatibility, haemolysis, thrombosis, implantability, physiologic control feasibility and pump performance. Conventional pump design equations based on Newton's law and computational fluid dynamics (CFD) are readily used for the initial design of VADs. In particular, CFD can be employed to predict the pressure-flow performance, hydraulic efficiencies, flow profile through the pump, stress levels and biophysical factors, such as possible blood cell damage. These computational flow simulations may involve comprehensive steady and transient flow analyses. The transient simulations involve time-varying boundary conditions and virtual modelling of the impeller rotation in the blood pumps. After prototype manufacture, laser flow measurements with sophisticated optics and mock circulatory flow loop testing assist with validation of pump design and identification of irregular flow patterns for optimization. Additionally, acute and chronic animal implants illustrate the blood pump's ability to support life physiologically. These extensive design techniques, coupled with fundamental principles of physics, ensure a reliable and effective VAD for thousands of heart failure patients each year

  19. Conventional radiography and computed tomography of cardiac assist devices

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Stolzmann, Paul; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Schertler, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wilhelm, Markus J.; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2009-09-15

    Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated. (orig.)

  20. Management issues during HeartWare left ventricular assist device implantation and the role of transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Sanjay Orathi Patangi

    2013-01-01

    Full Text Available Left ventricular assist devices (LVAD are increasingly used for mechanical circulatory support of patients with severe heart failure, primarily as a bridge to heart transplantation. Transesophageal echocardiography (TEE plays a major role in the clinical decision making during insertion of the devices and in the post-operative management of these patients. The detection of structural and device-related mechanical abnormalities is critical for optimal functioning of assist device. In this review article, we describe the usefulness of TEE for optimal perioperative management of patients presenting for HeartWare LVAD insertion.

  1. The Achilles' heel of left ventricular assist device therapy: right ventricle.

    Science.gov (United States)

    Ranganath, Neel K; Smith, Deane E; Moazami, Nader

    2018-06-01

    Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.

  2. The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    DEFF Research Database (Denmark)

    de By, Theo M M H; Mohacsi, Paul; Gummert, Jan

    2015-01-01

    other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry...

  3. Ventricular assist device implantation in a young patient with non-compaction cardiomyopathy and hereditary spherocytosis.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-04-01

    A case of a 15-year-old female patient with acute heart failure due to non-compaction cardiomyopathy and hereditary anaemia (hereditary spherocytic elliptocytosis) requiring ventricular assist device implantation as a bridge to transplantation is presented. The possible effects of mechanical stress on erythrocytes potentially induced by mechanical circulatory support remains unclear, but it may lead to haemolytic crisis in patients suffering from hereditary anaemia. In our case, ventricular assist device therapy was feasible, and haematological complications did not occur within 6 weeks of bridging our patient to heart transplantation.

  4. Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.

    Science.gov (United States)

    Pinney, Sean P

    2015-10-01

    Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: design and rationale of the ROADMAP clinical trial.

    Science.gov (United States)

    Rogers, Joseph G; Boyle, Andrew J; O'Connell, John B; Horstmanshof, Douglas A; Haas, Donald C; Slaughter, Mark S; Park, Soon J; Farrar, David J; Starling, Randall C

    2015-02-01

    Mechanical circulatory support is now a proven therapy for the treatment of patients with advanced heart failure and cardiogenic shock. The role for this therapy in patients with less severe heart failure is unknown. The objective of this study is to examine the impact of mechanically assisted circulation using the HeartMate II left ventricular assist device in patients who meet current US Food and Drug Administration-defined criteria for treatment but are not yet receiving intravenous inotropic therapy. This is a prospective, nonrandomized clinical trial of 200 patients treated with either optimal medical management or a mechanical circulatory support device. This trial will be the first prospective clinical evaluation comparing outcomes of patients with advanced ambulatory heart failure treated with either ongoing medical therapy or a left ventricular assist device. It is anticipated to provide novel insights regarding relative outcomes with each treatment and an understanding of patient and provider acceptance of the ventricular assist device therapy. This trial will also provide information regarding the risk of events in "stable" patients with advanced heart failure and guidance for the optimal timing of left ventricular assist device therapy. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Current Trends in Implantable Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2011-01-01

    Full Text Available The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. Improved results and the increased applicability and durability with left ventricular assist devices (LVADs have enhanced this treatment option available for end-stage heart failure patients. Moreover, outcome with newer pumps have evolved to destination therapy for such patients. Currently, results using nonpulsatile continuous flow pumps document the evolution in outcomes following destination therapy achieved subsequent to the landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure Trial (REMATCH, as well as the outcome of pulsatile designed second-generation LVADs. This review describes the currently available types of LVADs, their clinical use and outcomes, and focuses on the patient selection process.

  7. Mechanical circulatory treatment of advanced heart failure

    DEFF Research Database (Denmark)

    Løgstrup, Brian B; Vase, Henrik; Gjedsted, Jakob

    2016-01-01

    Heart failure is one of the most common causes of morbidity and mortality worldwide. When patients cease to respond adequately to optimal medical therapy mechanical circulatory support has been promising. The advent of mechanical circulatory support devices has allowed significant improvements...... in patient survival and quality of life for those with advanced or end-stage heart failure. We provide a general overview of current mechanical circulatory support devices encompassing options for both short- and long-term ventricular support....

  8. Development of ventricular assist devices in China: present status, opportunities and challenges.

    Science.gov (United States)

    Gu, Kaiyun; Chang, Yu; Gao, Bin; Wan, Feng; Loisance, Daniel; Zeng, Yi

    2014-08-01

    The growing number of heart failure patients and the scarcity of organ donors account for the huge need for the development of mechanical circulatory systems, including ventricular assist devices (VADs) and artificial hearts, in China. Several research programmes on blood pumps have been under way for the last three decades. However, unlike in other countries, the development of VADs has been extremely slow, and no system is currently approved and available for clinical application. There are many reasons for this situation. This article provides an overview of the present development of experimental and clinical research on VADs in China. In addition, the challenges for the clinical development of mechanical circulatory support in China are discussed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Predictors of survival and ability to wean from short-term mechanical circulatory support device following acute myocardial infarction complicated by cardiogenic shock.

    Science.gov (United States)

    Garan, A Reshad; Eckhardt, Christina; Takeda, Koji; Topkara, Veli K; Clerkin, Kevin; Fried, Justin; Masoumi, Amirali; Demmer, Ryan T; Trinh, Pauline; Yuzefpolskaya, Melana; Naka, Yoshifumi; Burkhoff, Dan; Kirtane, Ajay; Colombo, Paolo C; Takayama, Hiroo

    2017-11-01

    Cardiogenic shock following acute myocardial infarction (AMI-CS) portends a poor prognosis. Short-term mechanical circulatory support devices (MCSDs) provide hemodynamic support for patients with cardiogenic shock but predictors of survival and the ability to wean from short-term MCSDs remain largely unknown. All patients > 18 years old treated at our institution with extra-corporeal membrane oxygenation or short-term surgical ventricular assist device for AMI-CS were studied. We collected acute myocardial infarction details with demographic and hemodynamic variables. Primary outcomes were survival to discharge and recovery from MCSD (i.e. survival without heart replacement therapy including durable ventricular assist device or heart transplant). One hundred and twenty-four patients received extra-corporeal membrane oxygenation or short-term surgical ventricular assist device following acute myocardial infarction from 2007 to 2016; 89 received extra-corporeal membrane oxygenation and 35 short-term ventricular assist device. Fifty-five (44.4%) died in the hospital and 69 (55.6%) survived to discharge. Twenty-six (37.7%) required heart replacement therapy (four transplant, 22 durable ventricular assist device) and 43 (62.3%) were discharged without heart replacement therapy. Age and cardiac index at MCSD implantation were predictors of survival to discharge; patients over 60 years with cardiac index <1.5 l/min per m 2 had a low likelihood of survival. The angiographic result after revascularization predicted recovery from MCSD (odds ratio 9.00, 95% confidence interval 2.45-32.99, p=0.001), but 50% of those optimally revascularized still required heart replacement therapy. Cardiac index predicted recovery from MCSD among this group (odds ratio 4.06, 95% confidence interval 1.45-11.55, p=0.009). Among AMI-CS patients requiring short-term MCSDs, age and cardiac index predict survival to discharge. Angiographic result and cardiac index predict ventricular recovery but 50

  10. Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study

    OpenAIRE

    Biasetti, Jacopo; Pustavoitau, Aliaksei; Spazzini, Pier Giorgio

    2017-01-01

    Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into ...

  11. Short-term mechanical circulatory support as a bridge to durable left ventricular assist device implantation in refractory cardiogenic shock: a systematic review and meta-analysis.

    Science.gov (United States)

    den Uil, Corstiaan A; Akin, Sakir; Jewbali, Lucia S; Dos Reis Miranda, Dinis; Brugts, Jasper J; Constantinescu, Alina A; Kappetein, Arie Pieter; Caliskan, Kadir

    2017-07-01

    Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Prologue: ventricular assist devices and total artificial hearts. A historical perspective.

    Science.gov (United States)

    Frazier, O H

    2003-02-01

    In the 1960s, when LVADs and TAHs were introduced into clinical use, researchers estimated that, with this technology, the problem of heart failure could be solved within 20 years. Unfortunately, the evolution of these devices has taken much longer than anticipated. Nevertheless, significant advances have been achieved in both cardiac assistance and replacement, and today's cardiac surgeons have a wide range of devices from which to choose (Table 4). This progress has largely been due to the support of the NHLBI, especially the Devices and Technology Division headed by John Watson, and of the devoted commitment of the investigators. Because of the long-term commitment required for both basic and clinical research, commercial medical technology companies are unable to assume this burden. Advances in mechanical circulatory support and replacement have benefited numerous patients worldwide who would otherwise have died of heart failure, and devices now exist for use as bridges to recovery, bridges to transplant, and destination therapy. The current challenge is to refine what we have and to apply these technologies to broader patient populations with maximal safety and at a reasonable cost.

  13. Hemocompatibility of Axial Versus Centrifugal Pump Technology in Mechanical Circulatory Support Devices.

    Science.gov (United States)

    Schibilsky, David; Lenglinger, Matthias; Avci-Adali, Meltem; Haller, Christoph; Walker, Tobias; Wendel, Hans Peter; Schlensak, Christian

    2015-08-01

    The hemocompatible properties of rotary blood pumps commonly used in mechanical circulatory support (MCS) are widely unknown regarding specific biocompatibility profiles of different pump technologies. Therefore, we analyzed the hemocompatibility indicating markers of an axial flow and a magnetically levitated centrifugal device within an in vitro mock loop. The HeartMate II (HM II; n = 3) device and a CentriMag (CM; n = 3) adult pump were investigated in a human whole blood mock loop for 360 min using the MCS devices as a driving component. Blood samples were analyzed by enzyme-linked immunosorbent assay for markers of coagulation, complement system, and inflammatory response. There was a time-dependent activation of the coagulation (thrombin-antithrombin complexes [TAT]), complement (SC5b-9), and inflammation system (polymorphonuclear [PMN] elastase) in both groups. The mean value of TAT (CM: 4.0 μg/L vs. 29.4 μg/L, P technologies and a magnetically levitated centrifugal pump design might be superior. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals Inc.

  14. Bridge to recovery in two cases of dilated cardiomyopathy after long-term mechanical circulatory support

    OpenAIRE

    Pacholewicz, Jerzy; Zakliczy?ski, Micha?; Kowalik, Violetta; Nadziakiewicz, Pawe?; Kowalski, Oskar; Kalarus, Zbigniew; Zembala, Marian

    2014-01-01

    Ventricular assist devices (VADs) have become an established therapeutic option for patients with end-stage heart failure. Achieving the potential for recovery of native heart function using VADs is an established form of treatment in a selected group of patients with HF. We report two cases of VAD patients with different types of pump used for mechanical circulatory support, a continuous flow pump (Heart-Ware?) and a pulsatile pump (POLVAD MEV?), which allow regeneration of the native heart....

  15. Enhancement of arterial pressure pulsatility by controlling continuous-flow left ventricular assist device flow rate in mock circulatory system

    NARCIS (Netherlands)

    Bozkurt, S.; van de Vosse, F.N.; Rutten, M.C.M.

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase

  16. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-06-22

    ... information related to the humanitarian device exemption for the Berlin Heart EXCOR Pediatric Ventricular Assist Device (VAD) sponsored by Berlin Heart, Inc. The Berlin Heart EXCOR Pediatric VAD device is a..., please contact AnnMarie Williams, Conference Management Staff, at 301-796-5966, at least 7 days in...

  17. [Mechanical circulatory support in pediatrics. Experience at the Dr. Juan P. Garrahan Pediatric Hospital. Argentina].

    Science.gov (United States)

    Moreno, Guillermo E; Magliola, Ricardo; Pilán, María Luisa; Althabe, María; Balestrini, María; Lenz, Ana Miriam; Krysnki, Mariela; Rodríguez, Ricardo; Salgado, Gladys; Martin, Analía; Cardoso, Hugo; Ruffa, Pablo; Cornelis, Carlos Javier; Barreta, Jorge; García Delucis, Pablo

    2014-01-01

    Mechanical circulatory support provides oxygen to the tissues in patients with cardiac and/or respiratory reversible disease refractory to conventional treatments. The aim of this study is to show our initial results of mechanical circulatory support in children with heart disease. Retrospective cohort between March 2006 and March 2012. Demographic data (age, sex, weight, cardiac diagnosis), surgery (technique, pump, aortic cross clamping time) and mechanical circulatory support (type of assistance, indication, duration, complications and outcome) were collected. Thirty-three patients were supported (1.3% of all surgeries), extracorporeal membrane oxygenation 32 cases and one ventricular assist device. The median age 7.4 months (one day-18 years) and weight 6kg (2.3-75). The most frequent cardiac malformations supported were the transpositions of the great arteries associated with other anomalies and the corrected transpositions (ventricular inversion or double discordance). The most common reason for admission was post-cardiotomy biventricular dysfunction. Twenty-eight patients were supported in the postoperative period, 4 in the preoperative period and in one with myocarditis. Median days of support were 3 days (1-10). The most common complications were infection (21%), bleeding (21%). Elective decannulation was achieved in 94% of cases. Hospital discharge survival: 52%. The mechanical circulatory support in our institution is a safe and standard procedure. We have been using it in a small number of cases with a similar survival to that reported internationally. This complex procedure is widely justified because it allows for the recovery of more than half of the patients who otherwise would have died. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  18. Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century.

    Science.gov (United States)

    Throckmorton, Amy L; Patel-Raman, Sonna M; Fox, Carson S; Bass, Ellen J

    2016-06-01

    Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD involves a structured evaluation of possible system states, including human interaction with the device and auxiliary component usage in the hospital or home environment. In this study, we review the literature and present the current landscape of preclinical design and assessment, decision support tools and procedures, and patient-centered therapy. Gaps of knowledge are identified. The study findings support the need for more attention to user-centered design approaches for medical devices, such as mechanical circulatory assist systems, that specifically involve detailed qualitative and quantitative assessments of human-device interaction to mitigate risk and failure. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  20. First pediatric transatlantic air ambulance transportation on a Berlin Heart EXCOR left ventricular assist device as a bridge to transplantation.

    Science.gov (United States)

    Tissot, Cecile; Buchholz, Holger; Mitchell, Max B; da Cruz, Eduardo; Miyamoto, Shelley D; Pietra, Bill A; Charpentier, Arnaud; Ghez, Olivier

    2010-03-01

    Mechanical circulatory devices are indicated in patients with refractory cardiac failure as a bridge to recovery or to transplantation. Whenever required, transportation while on mechanical support is a challenge and still limited by technical restrictions or distance. We report the first pediatric case of transatlantic air transportation on a Berlin Heart EXCOR ventricular assist device (Berlin Heart, Berlin, Germany) of a 13-yr-old American female who presented in cardiogenic shock with severe systolic dysfunction while vacationing in France. Rapid hemodynamic deterioration occurred despite maximal medical treatment, and she was supported initially with extracorporeal membrane oxygenation converted to a Berlin Heart EXCOR left ventricular assist device. Long-distance air transportation of the patient was accomplished 3 wks after implantation from Marseille, France, to Denver, Colorado. No adverse hemodynamic effects were encountered during the 13.5-hr flight (8770 km). The patient did not recover sufficient cardiac function and underwent successful orthotopic heart transplantation 3 months after the initial event. Our experience suggests that long-distance air transportation of pediatric patients using the Berlin Heart EXCOR mobile unit as a bridge to recovery or transplantation is feasible and appears safe.

  1. Design of wheel-type walking-assist device

    International Nuclear Information System (INIS)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-01

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed

  2. Brain-controlled body movement assistance devices and methods

    Energy Technology Data Exchange (ETDEWEB)

    Leuthardt, Eric C.; Love, Lonnie J.; Coker, Rob; Moran, Daniel W.

    2017-01-10

    Methods, devices, systems, and apparatus, including computer programs encoded on a computer storage medium, for brain-controlled body movement assistance devices. In one aspect, a device includes a brain-controlled body movement assistance device with a brain-computer interface (BCI) component adapted to be mounted to a user, a body movement assistance component operably connected to the BCI component and adapted to be worn by the user, and a feedback mechanism provided in connection with at least one of the BCI component and the body movement assistance component, the feedback mechanism being configured to output information relating to a usage session of the brain-controlled body movement assistance device.

  3. The Effect of Preoperative Cognitive Behavior and Exercise Therapy for a Patient With an Implanted Left Ventricular Assist Device in Korea.

    Science.gov (United States)

    Seo, Yong Gon; Park, Won Hah; Jeon, Eun Seok; Sung, Ji Dong; Jang, Mi Ja

    2017-10-01

    Left ventricular assist devices (LVADs) are used in patients with progressive heart failure symptoms to provide circulatory support. Patients with LVADs are referred to inpatient cardiac rehabilitation to prevent postoperative complications and improve aerobic capacity and quality of life. Preoperative exercise therapy for cardiac patients is an emerging treatment modality, and several studies have reported that it improves postoperative outcomes, such as length of hospital stay and postoperative complications. This case report describes the benefits of preoperative cognitive behavioral and exercise therapy in a Korean patient undergoing LVAD implantation. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  4. Wearable Assistive Devices for the Blind

    OpenAIRE

    Velazquez, Ramiro

    2016-01-01

    Assistive devices are a key aspect in wearable systems for biomedical applications, as they represent potential aids for people with physical and sensory disabilities that might lead to improvements in the quality of life. This chapter focuses on wearable assistive devices for the blind. It intends to review the most significant work done in this area, to present the latest approaches for assisting this population and to understand universal design concepts for the development of wearable ass...

  5. Simulation of dilated heart failure with continuous flow circulatory support.

    Directory of Open Access Journals (Sweden)

    Yajuan Wang

    Full Text Available Lumped parameter models have been employed for decades to simulate important hemodynamic couplings between a left ventricular assist device (LVAD and the native circulation. However, these studies seldom consider the pathological descending limb of the Frank-Starling response of the overloaded ventricle. This study introduces a dilated heart failure model featuring a unimodal end systolic pressure-volume relationship (ESPVR to address this critical shortcoming. The resulting hemodynamic response to mechanical circulatory support are illustrated through numerical simulations of a rotodynamic, continuous flow ventricular assist device (cfVAD coupled to systemic and pulmonary circulations with baroreflex control. The model further incorporated septal interaction to capture the influence of left ventricular (LV unloading on right ventricular function. Four heart failure conditions were simulated (LV and bi-ventricular failure with/without pulmonary hypertension in addition to normal baseline. Several metrics of LV function, including cardiac output and stroke work, exhibited a unimodal response whereby initial unloading improved function, and further unloading depleted preload reserve thereby reducing ventricular output. The concept of extremal loading was introduced to reflect the loading condition in which the intrinsic LV stroke work is maximized. Simulation of bi-ventricular failure with pulmonary hypertension revealed inadequacy of LV support alone. These simulations motivate the implementation of an extremum tracking feedback controller to potentially optimize ventricular recovery.

  6. Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha

    Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.

  7. The pharmacotherapy implications of ventricular assist device in the patient with end-stage heart failure.

    Science.gov (United States)

    Von Ruden, Serena A S; Murray, Margaret A; Grice, Jennifer L; Proebstle, Amy K; Kopacek, Karen J

    2012-04-01

    Advances in mechanical circulatory support, such as the use of ventricular assist devices (VADs), have become a means for prolonging survival in end-stage heart failure (HF). VADs decrease the symptoms of HF and improve quality of life by replacing some of the work of a failing heart. They unload the ventricle to provide improved cardiac output and end-organ perfusion, resulting in improvement in cardiorenal syndromes and New York Heart Association functional class rating. VADs are currently used asa bridge to heart transplantation, a bridge to recovery of cardiac function, or as destination therapy. Complications of VAD include bleeding, infections, arrhythmias, multiple organ failure, right ventricular failure, and neurological dysfunction. Patients with VAD have unique pharmacotherapeutic requirements in terms of anticoagulation, appropriate antibiotic selection, and continuation of HF medications. Pharmacists in acute care and community settings are well prepared to care for the patient with VAD. These patients require thorough counseling and follow-up with regard to prevention and treatment of infections, appropriate levels of anticoagulation, and maintenance of fluid balance. A basic understanding of this unique therapy can assist pharmacists in attending to the needs of patients with VAD.

  8. Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

    Directory of Open Access Journals (Sweden)

    Spiliopoulos Sotirios

    2012-11-01

    Full Text Available Abstract Background Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. Clinical case We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an end-stage heart failure on the grounds of a dilated cardiomyopathy. Real-time pump blood flow was directly measured by an ultrasonic flow probe placed around the outflow graft. Diagnosis The progressive decline of real time flow and the loss of pulsatility were associated with an increase of central venous pressure, inotropic therapy and progressive renal failure suggesting the presence of an acute right heart failure. Diagnosis was validated by echocardiography and thermodilution measurements. Treatment Temporary mechanical circulatory support of the right ventricle was successfully performed. Real time flow measurement proved to be a useful tool for the diagnosis and ultimately for the management of right heart failure including the weaning from extracorporeal membrane oxygenation.

  9. Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol.

    Science.gov (United States)

    Heatley, Gerald; Sood, Poornima; Goldstein, Daniel; Uriel, Nir; Cleveland, Joseph; Middlebrook, Don; Mehra, Mandeep R

    2016-04-01

    The HeartMate 3 left ventricular assist system (LVAS; St. Jude Medical, Inc., formerly Thoratec Corporation, Pleasanton, CA) was recently introduced into clinical trials for durable circulatory support in patients with medically refractory advanced-stage heart failure. This centrifugal, fully magnetically levitated, continuous-flow pump is engineered with the intent to enhance hemocompatibility and reduce shear stress on blood elements, while also possessing intrinsic pulsatility. Although bridge-to-transplant (BTT) and destination therapy (DT) are established dichotomous indications for durable left ventricular assist device (LVAD) support, clinical practice has challenged the appropriateness of these designations. The introduction of novel LVAD technology allows for the development of clinical trial designs to keep pace with current practices. The prospective, randomized Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) clinical trial aims to evaluate the safety and effectiveness of the HeartMate 3 LVAS by demonstrating non-inferiority to the HeartMate II LVAS (also St. Jude Medical, Inc.). The innovative trial design includes patients enrolled under a single inclusion and exclusion criteria , regardless of the intended use of the device, with outcomes ascertained in the short term (ST, at 6 months) and long term (LT, at 2 years). This adaptive trial design includes a pre-specified safety phase (n = 30) analysis. The ST cohort includes the first 294 patients and the LT cohort includes the first 366 patients for evaluation of the composite primary end-point of survival to transplant, recovery or LVAD support free of debilitating stroke (modified Rankin score >3), or re-operation to replace the pump. As part of the adaptive design, an analysis by an independent statistician will determine whether sample size adjustment is required at pre-specified times during the study. A further 662

  10. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  11. Introduction of assistive devices: home nurses' practices and beliefs.

    Science.gov (United States)

    Roelands, Marc; Van Oost, Paulette; Depoorter, Anne Marie; Buysse, Ann; Stevens, Veerle

    2006-04-01

    This paper reports a study describing home nurses' intention and current practices regarding introducing assistive devices, and investigating whether their practice is related to social cognitive factors (attitudes, subjective norms and self-efficacy). Home nurses not only care for patients in particular medical domains, but also educate and guide them towards more independence. Patients with age-related disabilities in mobility and self-care might benefit from the use of assistive devices. A home nurse might be the first and only person to discuss the disability and use of an assistive device. Therefore, home nurses' beliefs about the introduction of assistive devices could affect their daily practices. A cross-sectional study was conducted with a convenience sample of 64 home nurses chosen from a random sample of home nursing departments. The home nurses completed a self-administered questionnaire. The Theory of Planned Behaviour framework was used to develop the social cognitive measures regarding each of the six steps distinguished in the introduction of assistive devices. Home nurses had positive attitudes and high levels of intention, subjective norm and self-efficacy towards most steps of the decision process to introduce assistive devices. In a multiple linear regression analysis, attitude and self-efficacy predicted intention to introduce assistive devices to older clients with disabilities. Intention was correlated to home nurses' current practices. The findings suggest that conditions are present to involve home nurses more explicitly in the introduction of assistive devices to their patients. Social cognitive factors should be taken into account when developing interventions that aim to support home nurses to do this.

  12. Efficient adders for assistive devices

    Directory of Open Access Journals (Sweden)

    Mansi Jhamb

    2017-02-01

    Full Text Available The Body sensor network [IEEE 802.15] is a wireless communication network consisting of assistive devices which are of prime importance in medical applications. The delay critical and power hungry blocks in these assistive devices are designed so that they consume less power, have low latency and require a lesser area on chip. In this paper, we present a qualitative as well as a quantitative analysis of an asynchronous pipelined adder design with two latest computation completion sensing approaches based on Pseudo NMOS logic and other based on C-element. The Pseudo NMOS based completion sensing approach provides a maximum improvement of 76.92% in critical path delay at supply voltage of 1.2 V and the maximum drop in power dissipation has been observed at a supply voltage of 1.1 V which is 85.60% as compared to C-element based completion sensing approach. Even at low voltages such as 0.8 V, there is a significant improvement in speed and power which is 75.64% and 74.79% respectively. Since the adder is the most widely used component in all present day assistive devices, this analysis acts as a pointer for the application of asynchronous pipelined circuits with efficient Pseudo NMOS based completion sensing approach in low voltage/low power rehabilitative devices.

  13. Interagency registry for mechanically assisted circulatory support report on the total artificial heart.

    Science.gov (United States)

    Arabía, Francisco A; Cantor, Ryan S; Koehl, Devin A; Kasirajan, Vigneshwar; Gregoric, Igor; Moriguchi, Jaime D; Esmailian, Fardad; Ramzy, Danny; Chung, Joshua S; Czer, Lawrence S; Kobashigawa, Jon A; Smith, Richard G; Kirklin, James K

    2018-04-26

    We sought to better understand the patient population who receive a temporary total artificial heart (TAH) as bridge to transplant or as bridge to decision by evaluating data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database. We examined data related to survival, adverse events, and competing outcomes from patients who received TAHs between June 2006 and April 2017 and used hazard function analysis to explore risk factors for mortality. Data from 450 patients (87% men; mean age, 50 years) were available in the INTERMACS database. The 2 most common diagnoses were dilated cardiomyopathy (50%) and ischemic cardiomyopathy (20%). Risk factors for right heart failure were present in 82% of patients. Most patients were INTERMACS Profile 1 (43%) or 2 (37%) at implantation. There were 266 patients who eventually underwent transplantation, and 162 died. Overall 3-, 6-, and 12-month actuarial survival rates were 73%, 62%, and 53%, respectively. Risk factors for death included older age (p = 0.001), need for pre-implantation dialysis (p = 0.006), higher creatinine (p = 0.008) and lower albumin (p Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  14. Real-Time ECG Simulation for Hybrid Mock Circulatory Loops.

    Science.gov (United States)

    Korn, Leonie; Rüschen, Daniel; Zander, Niklas; Leonhardt, Steffen; Walter, Marian

    2018-02-01

    Classically, mock circulatory loops only simulate mechanical properties of the circulation. To connect the hydraulic world with electrophysiology, we present a real-time electrical activity model of the heart and show how to integrate this model into a real-time mock loop simulation. The model incorporates a predefined conduction pathway and a simplified volume conductor to solve the bidomain equations and the forward problem of electrocardiography, resulting in a physiological simulation of the electrocardiogram (ECG) at arbitrary electrode positions. A complete physiological simulation of the heart's excitation would be too CPU intensive. Thus, in our model, complexity was reduced to allow real-time simulation of ECG-triggered medical systems in vitro; this decreases time and cost in the development process. Conversely, the presented model can still be adapted to various pathologies by locally changing the properties of the heart's conduction pathway. To simulate the ECG, the heart is divided into suitable areas, which are innervated by the hierarchically structured conduction system. To distinguish different cardiac regions, a segmentation of the heart was performed. In these regions, Prim's algorithm was applied to identify the directed minimal spanning trees for conduction orientation. Each node of the tree was assigned to a cardiac action potential generated by its hybrid automaton to represent the heart's conduction system by the spatial distribution of action potentials. To generate the ECG output, the bidomain equations were implemented and a simple model of the volume conductor of the body was used to solve the forward problem of electrocardiography. As a result, the model simulates potentials at arbitrary electrode positions in real-time. To verify the developed real-time ECG model, measurements were made within a hybrid mock circulatory loop, including a simple ECG-triggered ventricular assist device control. The model's potential value is to simulate

  15. Cerebrovascular accidents in patients with a ventricular assist device.

    Science.gov (United States)

    Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L

    2007-07-01

    A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.

  16. Role of long-term mechanical circulatory support in patients with advanced heart failure.

    Science.gov (United States)

    Stokes, M B; Bergin, P; McGiffin, D

    2016-05-01

    Advanced heart failure represents a small proportion of patients with heart failure that possess high-risk features associated with high hospital readmission rates, significant functional impairment and mortality. Identification of those who have progressed to, or are near a state of advanced heart failure should prompt referral to a service that offers therapies in mechanical circulatory support (MCS) and cardiac transplantation. MCS has grown as a management strategy in the care of these patients, most commonly as a bridge to cardiac transplantation. The predominant utilisation of MCS is implantation of left ventricular assist devices (LVAD), which have evolved significantly in their technology and application over the past 15-20 years. The technology has evolved to such an extent that Destination Therapy is now being utilised as a strategy in management of advanced heart failure in appropriately selected patients. Complication rates have decreased with VAD implantation, but remain a significant consideration in the decision to implant a device, and in the follow up of these patients. © 2016 Royal Australasian College of Physicians.

  17. Minimally Invasive Implantation of HeartWare Assist Device and Simultaneous Tricuspid Valve Reconstruction Through Partial Upper Sternotomy.

    Science.gov (United States)

    Hillebrand, Julia; Hoffmeier, Andreas; Djie Tiong Tjan, Tonny; Sindermann, Juergen R; Schmidt, Christoph; Martens, Sven; Scherer, Mirela

    2017-05-01

    Left ventricular assist device (LVAD) implantation is a well-established therapy to support patients with end-stage heart failure. However, the operative procedure is associated with severe trauma. Third generation LVADs like the HeartWare assist device (HeartWare, Inc., Framingham, MA, USA) are characterized by enhanced technology despite smaller size. These devices offer new minimally invasive surgical options. Tricuspid regurgitation requiring valve repair is frequent in patients with the need for mechanical circulatory support as it is strongly associated with ischemic and nonischemic cardiomyopathy. We report on HeartWare LVAD implantation and simultaneous tricuspid valve reconstruction through minimally invasive access by partial upper sternotomy to the fifth left intercostal space. Four male patients (mean age 51.72 ± 11.95 years) suffering from chronic heart failure due to dilative (three patients) and ischemic (one patient) cardiomyopathy and also exhibiting concomitant tricuspid valve insufficiency due to annular dilation underwent VAD implantation and tricuspid valve annuloplasty. Extracorporeal circulation was established via the ascending aorta, superior vena cava, and right atrium. In all four cases the LVAD implantation and tricuspid valve repair via partial median sternotomy was successful. During the operative procedure, no conversion to full sternotomy was necessary. One patient needed postoperative re-exploration because of pericardial effusion. No postoperative focal neurologic injury was observed. New generation VADs are advantageous because of the possibility of minimally invasive implantation procedure which can therefore minimize surgical trauma. Concomitant tricuspid valve reconstruction can also be performed simultaneously through partial upper sternotomy. Nevertheless, minimally invasive LVAD implantation is a challenging operative technique. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals

  18. Current Status of Mechanical Circulatory Support: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Kyriakos Spiliopoulos

    2012-01-01

    Full Text Available Heart failure is a major public health problem and its management requires a significant amount of health care resources. Even with administration of the best available medical treatment, the mortality associated with the disease remains high. As therapeutical strategies for heart failure have been refined, the number of patients suffering from the disease has expanded dramatically. Although heart transplantation still represents the gold standard therapeutical approach, the implantation of mechanical circulatory support devices (MCSDs evolved to a well-established management for this disease. The limited applicability of heart transplantation caused by a shortage of donor organs and the concurrent expand of the patient population with end-stage heart failure led to a considerable utilization of MCSDs. This paper outlines the current status of mechanical circulatory support.

  19. Myocardial changes in patients with end-stage heart failure during continuous flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, S.I.

    2013-01-01

    With respect to the clinical outcome, cf-LVADs provide sufficient ventricular unloading and circulatory support. The post-operative mortality and morbidity in our centre are comparable with other recent experiences with this device. Based on these data, Heart Mate II (HM II) LVAD therapy can be

  20. Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

    Science.gov (United States)

    Roszelle, Breigh N; Deutsch, Steven; Manning, Keefe B

    2010-02-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV) as a flow visualization technique, however the small size and high curvature of the PVAD make other tools such as stereoscopic PIV impractical. In order to test the reliability of the 2D results, we perform a pseudo-3D PIV study using planes both parallel and normal to the diaphragm employing a mock circulatory loop containing a viscoelastic fluid that mimics 40% hematocrit blood. We find that while the third component of velocity is extremely helpful to a physical understanding of the flow, particularly of the diastolic jet and the development of a desired rotational pattern, the flow data taken parallel to the diaphragm is sufficient to describe the wall shear rates, a critical aspect to the study of thrombosis and design of such pumps.

  1. Advances in bioartificial liver assist devices.

    Science.gov (United States)

    Patzer, J F

    2001-11-01

    Rapid advances in development of bioartificial liver assist devices (BLADs) are exciting clinical interest in the application of BLAD technology for support of patients with acute liver failure. Four devices (Circe Biomedical HepatAssist, Vitagen ELAD, Gerlach BELS, and Excorp Medical BLSS) that rely on hepatocytes cultured in hollow-fiber membrane technology are currently in various stages of clinical evaluation. Several alternative approaches for culture and perfusion of hepatocytes have been evaluated in preclinical, large animal models of liver failure, or at a laboratory scale. Engineering design issues with respect to xenotransplantation, BLAD perfusion, hepatocyte functionality and culture maintenance, and ultimate distribution of a BLAD to a clinical site are delineated.

  2. Vapor cycle energy system for implantable circulatory assist devices. Final summary May--Oct 1976

    International Nuclear Information System (INIS)

    Watelet, R.P.; Ruggles, A.E.; Hagen, K.G.

    1977-03-01

    The report describes the development status of a heart assist system driven by a nuclear-fueled, electronically controlled vapor cycle engine termed the tidal regenerator engine (TRE). The TRE pressurization is controlled by a torque motor coupled to a displacer. The electrical power for the sensor, electronic logic and actuator is provided by thermoelectric modules interposed between the engine superheater and boiler. The TRE is direct-coupled to an assist blood pump which also acts as a blood-cooled heat exchanger, pressure-volume trasformer and sensor for the electronic logic. Engine cycle efficiency in excess of 14% has been demonstrated routinely. Overall system efficiency on 33 watts of over 9% has been demonstrated (implied 13% engine cycle efficiency). A binary version of this engine in the annular configuration is now being tested. The preliminary tests demonstrated 10% cycle efficiency on the first buildup which ran well and started easily

  3. Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study

    Directory of Open Access Journals (Sweden)

    Jacopo Biasetti

    2017-10-01

    Full Text Available Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into electricity to power circulatory support devices. Due to the low conversion efficiencies, substantial levels of waste heat are generated and must be dissipated to avoid tissue damage, heat stroke, and death. The present work computationally evaluates the ability of the blood flow in the descending aorta to remove the locally generated waste heat for subsequent full-body distribution and dissipation, with the specific aim of investigating methods for containment of local peak temperatures within physiologically acceptable limits. To this aim, coupled fluid–solid heat transfer computational models of the blood flow in the human aorta and different heat exchanger architectures are developed. Particle tracking is used to evaluate temperature histories of cells passing through the heat exchanger region. The use of the blood flow in the descending aorta as a heat sink proves to be a viable approach for the removal of waste heat loads. With the basic heat exchanger design, blood thermal boundary layer temperatures exceed 50°C, possibly damaging blood cells and proteins. Improved designs of the heat exchanger, with the addition of fins and heat guides, allow for drastically lower blood temperatures, possibly leading to a more biocompatible implant. The ability to maintain blood temperatures at biologically compatible levels will ultimately allow for the body-wise distribution, and subsequent dissipation, of heat loads with minimum effects on the human physiology.

  4. Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study.

    Science.gov (United States)

    Biasetti, Jacopo; Pustavoitau, Aliaksei; Spazzini, Pier Giorgio

    2017-01-01

    Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into electricity to power circulatory support devices. Due to the low conversion efficiencies, substantial levels of waste heat are generated and must be dissipated to avoid tissue damage, heat stroke, and death. The present work computationally evaluates the ability of the blood flow in the descending aorta to remove the locally generated waste heat for subsequent full-body distribution and dissipation, with the specific aim of investigating methods for containment of local peak temperatures within physiologically acceptable limits. To this aim, coupled fluid-solid heat transfer computational models of the blood flow in the human aorta and different heat exchanger architectures are developed. Particle tracking is used to evaluate temperature histories of cells passing through the heat exchanger region. The use of the blood flow in the descending aorta as a heat sink proves to be a viable approach for the removal of waste heat loads. With the basic heat exchanger design, blood thermal boundary layer temperatures exceed 50°C, possibly damaging blood cells and proteins. Improved designs of the heat exchanger, with the addition of fins and heat guides, allow for drastically lower blood temperatures, possibly leading to a more biocompatible implant. The ability to maintain blood temperatures at biologically compatible levels will ultimately allow for the body-wise distribution, and subsequent dissipation, of heat loads with minimum effects on the human physiology.

  5. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    Science.gov (United States)

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  6. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    Science.gov (United States)

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Performance of Noninvasive Assessment in the Diagnosis of Right Heart Failure After Left Ventricular Assist Device.

    Science.gov (United States)

    Joly, Joanna M; El-Dabh, Ashraf; Marshell, Ramey; Chatterjee, Arka; Smith, Michelle G; Tresler, Margaret; Kirklin, James K; Acharya, Deepak; Rajapreyar, Indranee N; Tallaj, José A; Pamboukian, Salpy V

    2018-06-01

    Right heart failure (RHF) after left ventricular assist device (LVAD) is associated with poor outcomes. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) defines RHF as elevated right atrial pressure (RAP) plus venous congestion. The purpose of this study was to examine the diagnostic performance of the noninvasive INTERMACS criteria using RAP as the gold standard. We analyzed 108 patients with LVAD who underwent 341 right heart catheterizations (RHC) between January 1, 2006, and December 31, 2013. Physical exam, echocardiography, and laboratory data at the time of RHC were collected. Conventional two-by-two tables were used and missing data were excluded. The noninvasive INTERMACS definition of RHF is 32% sensitive (95% CI, 0.21-0.44) and 97% specific (95% CI, 0.95-0.99) for identifying elevated RAP. Clinical assessment failed to identify two-thirds of LVAD patients with RAP > 16 mm Hg. More than half of patients with elevated RAP did not have venous congestion, which may represent a physiologic opportunity to mitigate the progression of disease before end-organ damage occurs. One-quarter of patients who met the noninvasive definition of RHF did not actually have elevated RAP, potentially exposing patients to unnecessary therapies. In practice, if any component of the INTERMACS definition is present or equivocal, our data suggest RHC is warranted to establish the diagnosis.

  8. The role of cerebral hyperperfusion in postoperative neurologic dysfunction after left ventricular assist device implantation for end-stage heart failure.

    Science.gov (United States)

    Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M

    2009-04-01

    Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.

  9. Implantable nuclear-fueled circulatory support system. V. Acute physiologic analyses

    Energy Technology Data Exchange (ETDEWEB)

    Huffman, F N; Migliore, J J; Hagen, K G; Daly, B D.T.; Robinson, W J; Ruggles, A E; Norman, J C

    1973-01-01

    Nuclear-Fueled circulatory assist systems have reached the stage of in vivo evaluation. Physiologic studies of the effects of intracorporeal heat and radiation as well as blood pumps indicate that these factors should not preclude clinical application of nuclear artificial hearts. In the circulatory system under consideration, a fraction of the heat from a 50 watt Plutonium-238 fuel capsule is converted into hydraulic power for driving a left ventricular assist pump via a miniature, electronically controlled steam (tidal regenerator) engine. The engine is pressurized (8-140 PSIA) by the displacement of a single drop of water between the condenser (150/sup 0/F) and the boiler (360/sup 0/F). The electrical power for sensing, logic and displacement is provided by a thermoelectric module interposed between the superheater (900/sup 0/F) and boiler. The pusher plate pump also functions as a blood-cooled heat exchanger and sensor for the control logic. The assist pump is connected between the apex of the left ventricle and the descending thoracic aorta. The power source module is suspended in the left retroperitoneal cavity from the psoas tendon. The blood interface of the pump is flocked with polyester fibers. A stable biologic lining develops in the pump using Dextran as the only anticoagulant. The longest in vivo testing period has been 4/sup 1///sub 2/ days. Plasma hemoglobinshave remained below 10 mg/sup 0///sub 0/. Although rectal temperatures have not increased, elevated respiratory rates have been noted. Reduction of left ventricular pressure and dp/dt have been demonstrated with maintenance of arterial pressure.

  10. Analysis of Contemporary Methods for Designing Rotary Type Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    E. P. Banin

    2015-01-01

    Full Text Available The research object is inlet apparatus of ventricular assist device, namely inlet cannula and straightener.The purpose of the study is to reveal features of blood flow in inlet apparatus of ventricular assist device. The mathematical modeling is carried out by computational fluid dynamics analysis in a stationary setting.The first part of study concerns the analysis of existing approaches to the numerical and experimental studies in designing the ventricular assist devices of rotary type. It reveals the features of each approach for their further application in practice. The article presents an original design of developed hydraulic test bench to verify the results of mathematical modeling. Analysis of foreign authors’ studies showed that there is no enough attention paid to design of the adjacent pump assemblies of ventricular assist device. The second part of study considers direct mathematical modeling of input apparatus of ventricular assist device. The study examined straightener with three or four blades. Mathematical modeling has revealed the presence of potentially dangerous stagnation zones and essential asymmetry of the outlet flow from the input unit. The found features must be taken in consideration in designing the ventricular assist device pumps. In the future we plan to use obtained data to create a parametric model of the rotor and the diffuser considering the abovementioned features.

  11. Comparative analysis of von Willebrand factor profiles after implantation of left ventricular assist device and total artificial heart.

    Science.gov (United States)

    Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O

    2017-08-01

    Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and

  12. Evaluation of Automated Flagger Assistance Devices

    Science.gov (United States)

    2018-02-01

    Automated flagger assistance devices (AFADs) are designed to improve worker safety by replacing flaggers who are typically located near traffic approaching a work zone. In this study, a new AFAD developed by the Missouri Department of Transportation ...

  13. Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe

    2018-05-08

    Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index 17 (OR 3.5 [1.9-6.9], p the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.

  14. A novel implantable electromechanical ventricular assist device - First acute animal testing

    NARCIS (Netherlands)

    Kaufmann, R; Rakhorst, G; Mihaylov, D; Elstrodt, J; Nix, C; Reul, H; Rau, G

    1997-01-01

    A novel ventricular assist device (HIA-EMLVAD-AT1, Helmholtz Institute Aachen-electromechanical Left Ventricular Assist Device-Animal Test Version 1), driven by a uniformly and unidirectionally rotating actuator and a patented hypocycloidic pusherplate displacement gear unit, was developed and

  15. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  16. Vapor cycle energy system for implantable circulatory assist devices. Annual progress report Jul 1974--Jun 1975

    International Nuclear Information System (INIS)

    Hagen, K.G.

    1975-06-01

    The report describes the development status of a heart assist system driven by a nuclear fueled, electronically controlled vapor cycle engine termed the tidal regenerator engine (TRE). The TRE pressurization (typically from 5-160 psia) is controlled by a torque motor coupled to a displacer. The electrical power for the sensor, electronic logic and actuator is provided by a thermoelectric module interposed between the engine superheater and boiler. The TRE is direct coupled to an assist blood pump which also acts as a blood-cooled heat exchanger, pressure-volume transformer and sensor for the electronic logic. Engine efficiencies in excess of 14% have been demonstrated. Efficiency values as high as 13% have been achieved to date

  17. Pediatric Donation After Circulatory Determination of Death: A Scoping Review.

    Science.gov (United States)

    Weiss, Matthew J; Hornby, Laura; Witteman, William; Shemie, Sam D

    2016-03-01

    Although pediatric donation after circulatory determination of death is increasing in frequency, there are no national or international donation after circulatory determination of death guidelines specific to pediatrics. This scoping review was performed to map the pediatric donation after circulatory determination of death literature, identify pediatric donation after circulatory determination of death knowledge gaps, and inform the development of national or regional pediatric donation after circulatory determination of death guidelines. Terms related to pediatric donation after circulatory determination of death were searched in Embase and MEDLINE, as well as the non-MEDLINE sources in PubMed from 1980 to May 2014. Seven thousand five hundred ninety-seven references were discovered and 85 retained for analysis. All references addressing pediatric donation after circulatory determination of death were considered. Exclusion criteria were articles that did not address pediatric patients, animal or laboratory studies, surgical techniques, and local pediatric donation after circulatory determination of death protocols. Narrative reviews and opinion articles were the most frequently discovered reference (25/85) and the few discovered studies were observational or qualitative and almost exclusively retrospective. Retained references were divided into themes and analyzed using qualitative methodology. The main discovered themes were 1) studies estimating the number of potential pediatric donation after circulatory determination of death donors and their impact on donation; 2) ethical issues in pediatric donation after circulatory determination of death; 3) physiology of the dying process after withdrawal of life-sustaining therapy; 4) cardiac pediatric donation after circulatory determination of death; and 5) neonatal pediatric donation after circulatory determination of death. Donor estimates suggest that pediatric donation after circulatory determination of death will

  18. Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device.

    Science.gov (United States)

    Nam, Kyoung Won; Lee, Jung Joo; Hwang, Chang Mo; Choi, Seong Wook; Son, Ho Sung; Sun, Kyung

    2007-11-01

    Currently, personal mobile communication devices have become quite common, and the applications of such devices have expanded quickly. Remote communication systems might be employed for the telemonitoring of patients or the operating status of their medical devices. In this article, we describe the development of a mobile-based artificial heart telemanagement system for use in a wearable extracorporeal pneumatic biventricular assist device, which is capable of telemonitoring and telecontrolling the operating status of the ventricular assist device from any site. The system developed herein utilized small mobile phones for the client device and adopted a standard transmission control protocol/Internet protocol communication protocol for the purposes of telecommunication. The results of in vitro and animal experiments showed that the telemanagement system developed herein operated in accordance with the desired parameters.

  19. Left ventricular assist device (lvad design features: literature review

    Directory of Open Access Journals (Sweden)

    Yu. V. Bogdanova

    2014-01-01

    Full Text Available More than 8 million people in our country suffer from heart failure. About one million of these people die each year [1]. The problem of ventricular assist device creating - a mechanical device used for partial or complete replacement of heart function - is investigated for a long time (according to [2] just in our country since the 1970s. Today plenty of encouraging results are received. There is a number of VAD models which are successfully applied to patients with heart failure. After implantation, patients conduct a way of life that is normal in many respects: they are in the family, often they have an opportunity to work in their former specialty. Some of them live with the device about 8 years [3].According to [4] for 2010 the estimated total number of long-term devices implanted in the United States per year is over 1,700 (the population of the U.S. is 305 million, compared with over 430 per year in Europe (the population of Europe is 731 million. Unfortunately, people who need a heart transplant are much more.The principle of VAD is that being connected to the left ventricle with one cannula and to the ascending aorta with the other cannula the pump fully or partially replaces the function of the natural heart. This scheme allows the use of VAD in two ways: as a "bridge to transplantation" when the device is used temporarily until the donor heart is found, and a "bridge to recovery", when through the use of VAD the function of the heart muscle is recovered.VAD system can be divided into three subsystems: blood pump, power supply system and control system (Fig. 1.Each subsystem can be the subject of separate study. Special role in the development of VAD plays medical side of the issue. Successful research and development require interaction with qualified professionals in this field. The development of VAD is a multidisciplinary problem which demands fulfilment of a number of requirements.One of the most active programs in implantation of

  20. A numerical method to enhance the performance of a cam-type electric motor-driven left ventricular assist device.

    Science.gov (United States)

    Huang, Huan; Yang, Ming; Lu, Cunyue; Xu, Liang; Zhuang, Xiaoqi; Meng, Fan

    2013-10-01

    Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  1. Factors influencing the outcome of paediatric cardiac surgical patients during extracorporeal circulatory support

    Directory of Open Access Journals (Sweden)

    Peek Giles J

    2007-01-01

    Full Text Available Abstract Background Veno-arterial extracorporeal membrane oxygenation (ECMO is a common modality of circulatory assist device used in children. We assessed the outcome of children who had ECMO following repair of congenital cardiac defects (CCD and identified the risk factors associated with hospital mortality. Methods From April 1990 to December 2003, 53 patients required ECMO following surgical correction of CCD. Retrospectively collected data was analyzed with univariate and multivariate logistic regression analysis. Results Median age and weight of the patients were 150 days and 5.4 kgs respectively. The indications for ECMO were low cardiac output in 16, failure to wean cardiopulmonary bypass in 13, cardiac arrest in 10 and cardio-respiratory failure in 14 patients. The mean duration of ECMO was 143 hours. Weaning off from ECMO was successful in 66% and of these 83% were survival to hospital-discharge. 37.7% of patients were alive for the mean follow-up period of 75 months. On univariate analysis, arrhythmias, ECMO duration >168 hours, bleeding complications, renal replacement therapy on ECMO, arrhythmias and cardiac arrest after ECMO were associated with hospital mortality. On multivariate analysis, abnormal neurology, bleeding complications and arrhythmias after ECMO were associated with hospital mortality. Extra and intra-thoracic cannulations were used in 79% and 21% of patients respectively and extra-thoracic cannulation had significantly less bleeding complications (p = 0.031. Conclusion ECMO provides an effective circulatory support following surgical repair of CCD in children. Extra-thoracic cannulation is associated with less bleeding complications. Abnormal neurology, bleeding complications on ECMO and arrhythmias after ECMO are poor prognostic indicators for hospital survival.

  2. Percutaneous Repair of Postoperative Mitral Regurgitation After Left Ventricular Assist Device Implant.

    Science.gov (United States)

    Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian

    2018-02-01

    Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Donations After Circulatory Death in Liver Transplant.

    Science.gov (United States)

    Eren, Emre A; Latchana, Nicholas; Beal, Eliza; Hayes, Don; Whitson, Bryan; Black, Sylvester M

    2016-10-01

    The supply of liver grafts for treatment of end-stage liver disease continues to fall short of ongoing demands. Currently, most liver transplants originate from donations after brain death. Enhanced utilization of the present resources is prudent to address the needs of the population. Donation after circulatory or cardiac death is a mechanism whereby the availability of organs can be expanded. Donations after circulatory death pose unique challenges given their exposure to warm ischemia. Technical principles of donations after circulatory death procurement and pertinent studies investigating patient outcomes, graft outcomes, and complications are highlighted in this review. We also review associated risk factors to suggest potential avenues to achieve improved outcomes and reduced complications. Future considerations and alternative techniques of organ preservation are discussed, which may suggest novel strategies to enhance preservation and donor expansion through the use of marginal donors. Ultimately, without effective measures to bolster organ supply, donations after circulatory death should remain a consideration; however, an understanding of inherent risks and limitations is necessary.

  4. 78 FR 34922 - Definition of Auditory Assistance Device

    Science.gov (United States)

    2013-06-11

    ... permitting such use of these devices would increase the comprehension of persons that need language... communications (including but not limited to applications such as assistive listening, auricular training, audio...

  5. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    Science.gov (United States)

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.

  6. Extracorporeal circulatory systems in the interhospital transfer of critically ill patients: experience of a single institution

    International Nuclear Information System (INIS)

    Haneya, Assad; Philipp, Alois; Foltan, Maik; Camboni, Daniele; Rupprecht, Leopold; Puehler, Thomas; Hirt, Stephan; Hilker, Michael; Kobuch, Reinhard; Schmid, Christof; Arlt, Matthias; Mueller, Thomas

    2009-01-01

    Critically ill patients with acute circulatory failure cannot be moved to other institutions unless stabilized by mechanical support systems. Extracorporeal heart and lung assist systems are increasingly used as a bridge to end-organ recovery or transplantation, and as an ultimate rescue tool in cardiopulmonary resuscitation. From July 2001 to April 2008, we had 38 requests for extracorporeal support for interhospital transfer carried out by the air medical service. Respiratory failure was present in 29 patients, who were provided with pumpless extracorporeal lung assist (PECLA) or veno-venous extracorporeal membrane oxygenation (ECMO). Cardiac failure dominated in 9 patients, who underwent implantation of extracorporeal life support (ECLS). Underlying diseases were acute respiratory distress syndrome in 15 patients, pneumonia in 7, prior lung transplant status in 4, cardiogenic shock in 7, and septic shock in 4. All assist systems were connected via peripheral vessels by the Seldinger technique. Transport was uneventful in all cases with no technical failures. On arrival at the specialized care hospital, two patients had leg ischemia and underwent relocation of the arterial cannula. After a mean (SD) support of 5.1 (3.0) days for PECLA, 3.5 (2.9) days for ECLS, and 7.3 (5.8) days for ECMO, 60%, 66%, and 66% of patients, respectively, could be successfully weaned from the systems. Discharge rates were 45% for PECLA, 44% for ECLS, and 56% for ECMO. Our experience proves that minimized extracorporeal assist devices allow safe assistance of patients with isolated or combined heart and lung failure in need of interhospital transfer. Critically ill patients get a chance to reach a center of maximum medical care. (author)

  7. Mycobacterium chimaera left ventricular assist device infections.

    Science.gov (United States)

    Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S

    2017-06-01

    A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.

  8. Comparison of Transplant Waitlist Outcomes for Pediatric Candidates Supported by Ventricular Assist Devices Versus Medical Therapy.

    Science.gov (United States)

    Law, Sabrina P; Oron, Assaf P; Kemna, Mariska S; Albers, Erin L; McMullan, D Michael; Chen, Jonathan M; Law, Yuk M

    2018-05-01

    Ventricular assist devices have gained popularity in the management of refractory heart failure in children listed for heart transplantation. Our primary aim was to compare the composite endpoint of all-cause pretransplant mortality and loss of transplant eligibility in children who were treated with a ventricular assist device versus a medically managed cohort. This was a retrospective cohort analysis. Data were obtained from the Scientific Registry of Transplant Recipients. The at-risk population (n = 1,380) was less than 18 years old, either on a ventricular assist device (605 cases) or an equivalent-severity, intensively medically treated group (referred to as MED, 775 cases). None. The impact of ventricular assist devices was estimated via Cox proportional hazards regression (hazard ratio), dichotomizing 1-year outcomes to "poor" (22%: 193 deaths, 114 too sick) versus all others (940 successful transplants, 41 too healthy, 90 censored), while adjusting for conventional risk factors. Among children 0-12 months old, ventricular assist device was associated with a higher risk of poor outcomes (hazard ratio, 2.1; 95% CI, 1.5-3.0; p comparative study of ventricular assist devices versus medical therapy in children. Age is a significant modulator of waitlist outcomes for children with end-stage heart failure supported by ventricular assist device, with the impact of ventricular assist devices being more beneficial in adolescents.

  9. Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System: A Novel Approach Using Log File Analysis.

    Science.gov (United States)

    Jorde, Ulrich P; Aaronson, Keith D; Najjar, Samer S; Pagani, Francis D; Hayward, Christopher; Zimpfer, Daniel; Schlöglhofer, Thomas; Pham, Duc T; Goldstein, Daniel J; Leadley, Katrin; Chow, Ming-Jay; Brown, Michael C; Uriel, Nir

    2015-11-01

    The study sought to characterize patterns in the HeartWare (HeartWare Inc., Framingham, Massachusetts) ventricular assist device (HVAD) log files associated with successful medical treatment of device thrombosis. Device thrombosis is a serious adverse event for mechanical circulatory support devices and is often preceded by increased power consumption. Log files of the pump power are easily accessible on the bedside monitor of HVAD patients and may allow early diagnosis of device thrombosis. Furthermore, analysis of the log files may be able to predict the success rate of thrombolysis or the need for pump exchange. The log files of 15 ADVANCE trial patients (algorithm derivation cohort) with 16 pump thrombus events treated with tissue plasminogen activator (tPA) were assessed for changes in the absolute and rate of increase in power consumption. Successful thrombolysis was defined as a clinical resolution of pump thrombus including normalization of power consumption and improvement in biochemical markers of hemolysis. Significant differences in log file patterns between successful and unsuccessful thrombolysis treatments were verified in 43 patients with 53 pump thrombus events implanted outside of clinical trials (validation cohort). The overall success rate of tPA therapy was 57%. Successful treatments had significantly lower measures of percent of expected power (130.9% vs. 196.1%, p = 0.016) and rate of increase in power (0.61 vs. 2.87, p file parameters can potentially predict the likelihood of successful tPA treatments and if validated prospectively, could substantially alter the approach to thrombus management. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Ethical Analysis of Withdrawing Ventricular Assist Device Support

    OpenAIRE

    Mueller, Paul S.; Swetz, Keith M.; Freeman, Monica R.; Carter, Kari A.; Crowley, Mary Eliot; Severson, Cathy J. Anderson; Park, Soon J.; Sulmasy, Daniel P.

    2010-01-01

    OBJECTIVE: To describe a series of patients with heart failure supported with a ventricular assist device (VAD) who requested (or whose surrogates requested) withdrawal of VAD support and the legal and ethical aspects pertaining to these requests.

  11. Risk stratification in patients with advanced heart failure requiring biventricular assist device support as a bridge to cardiac transplantation.

    Science.gov (United States)

    Cheng, Richard K; Deng, Mario C; Tseng, Chi-hong; Shemin, Richard J; Kubak, Bernard M; MacLellan, W Robb

    2012-08-01

    Prior studies have identified risk factors for survival in patients with end-stage heart failure (HF) requiring left ventricular assist device (LVAD) support. However, patients with biventricular HF may represent a unique cohort. We retrospectively evaluated a consecutive cohort of 113 adult, end-stage HF patients at University of California Los Angeles Medical Center who required BIVAD support between 2000 and 2009. Survival to transplant was 66.4%, with 1-year actuarial survival of 62.8%. All patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Level 1 or 2 and received Thoratec (Pleasanton, CA) paracorporeal BIVAD as a bridge to transplant. Univariate analyses showed dialysis use, ventilator use, extracorporal membrane oxygenation use, low cardiac output, preserved LV ejection fraction (restrictive physiology), normal-to-high sodium, low platelet count, low total cholesterol, low high-density and high-density lipoprotein, low albumin, and elevated aspartate aminotransferase were associated with increased risk of death. We generated a scoring system for survival to transplant. Our final model, with age, sex, dialysis, cholesterol, ventilator, and albumin, gave a C-statistic of 0.870. A simplified system preserved a C-statistic of 0.844. Patients were divided into high-risk or highest-risk groups (median respective survival, 367 and 17 days), with strong discrimination between groups for death. We have generated a scoring system that offers high prognostic ability for patients requiring BIVAD support and hope that it may assist in clinical decision making. Further studies are needed to prospectively validate our scoring system. Copyright © 2012 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  12. Vascular and Immunobiology of the Circulatory Sphingosine 1-Phosphate Gradient

    Science.gov (United States)

    Yanagida, Keisuke; Hla, Timothy

    2017-01-01

    Vertebrates are endowed with a closed circulatory system, the evolution of which required novel structural and regulatory changes. Furthermore, immune cell trafficking paradigms adapted to the barriers imposed by the closed circulatory system. How did such changes occur mechanistically? We propose that spatial compartmentalization of the lipid mediator sphingosine 1-phosphate (S1P) may be one such mechanism. In vertebrates, S1P is spatially compartmentalized in the blood and lymphatic circulation, thus comprising a sharp S1P gradient across the endothelial barrier. Circulatory S1P has critical roles in maturation and homeostasis of the vascular system as well as in immune cell trafficking. Physiological functions of S1P are tightly linked to shear stress, the key biophysical stimulus from blood flow. Thus, circulatory S1P confinement could be a primordial strategy of vertebrates in the development of a closed circulatory system. This review discusses the cellular and molecular basis of the S1P gradients and aims to interpret its physiological significance as a key feature of the closed circulatory system. PMID:27813829

  13. Protéolyse du facteur Willebrand et cardiopathies à forces de cisaillement élevées : nouvelles approches diagnostiques et thérapeutiques

    OpenAIRE

    Rauch , Antoine

    2014-01-01

    In the first part of the thesis, we describe a novel approach based on antibody-based therapy to prevent the acquired von Willebrand factor (VWF) degradation observed in continuous-flow mechanical circulatory assist device therapy. Via a murine monoclonal antibody directed against VWF D4 domain and thus interfering with VWF-ADAMTS13 binding, a partial inhibition of VWF degradation is observed in whole blood using an ex vivo circulatory assist device model. In the second part of the thesis, we...

  14. Monitoring and assay procedures for krypton-85 used in circulatory tests

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jr., J. M.; Williams, K. D.

    1963-11-15

    During the past five years, krypton-85 has been used extensively at the National Institutes of health and by the heart Catheterization laboratory in the identification of circulatory shunts. Several methods of assaying the incoming shipments of radioactive gas are given. These consist of ionization chamber measurements, gamma ray spectrometry, and gross photon counting of the cylinder surface with an end-window Geiger-Mueller tube. A device (consisting of a log-count-rate meter, recorder, and G.M. tube) is used to continuously monitor the laboratory. The method of calibrating this device is presented. A means for removing contaminated air from the vicinity of the operating table was devised. The results of air clearance studies of the room are included. (auth)

  15. Assistive device use and mobility-related factors among adults aged≥65years.

    Science.gov (United States)

    West, Bethany A; Bhat, Geeta; Stevens, Judy; Bergen, Gwen

    2015-12-01

    Examining how assistive device (cane, walker) use relates to other mobility factors can provide insight into older adults' future mobility needs. Data come from the Second Injury Control and Risk Survey, Phase 2 (ICARIS2-P2), conducted from March 2007 to May 2008. Prevalence estimates were calculated for older adults (aged ≥65) and multivariable logistic regression was used to explore associations between assistive device use and mobility-related characteristics. Compared with non-users, assistive device users were more likely to report a recent fall (AOR 12.0; 95% CI 4.9-29.3), limit walking outside due to concerns about falling (AOR 7.1; 95% CI 2.6-19.1), be unable to walk outside for 10min without resting (AOR 3.3; 95% CI 1.1-9.3), and be no longer driving (AOR 6.7; 95% CI 2.0-22.3). Assistive device users have limited mobility and an increased risk for fall injury compared with non-users. Effective fall prevention interventions, and innovative transportation options, are needed to protect the mobility of this high-risk group. Published by Elsevier Ltd.

  16. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  17. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  18. Right heart failure and "failure to thrive" after left ventricular assist device: clinical predictors and outcomes.

    Science.gov (United States)

    Baumwol, Jay; Macdonald, Peter S; Keogh, Anne M; Kotlyar, Eugene; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S

    2011-08-01

    This study determined predictors of early post-operative right heart failure (RHF) and its consequences, as well as predictors of those who clinically thrive longer term after insertion of a continuous-flow left ventricular assist device (LVAD). Pre-operative and latest follow-up data were analyzed for 40 consecutive patients who received third-generation centrifugal-flow LVADs. RHF was defined using previously described criteria, including post-operative inotropes, pulmonary vasodilator use, or right-sided mechanical support. Patients were also categorized according to clinical outcomes after LVAD insertion. LVADs were implanted as a bridge to transplantation (BTT) in 33 patients and as destination therapy in 7. Before LVAD implant, 22 patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level 1, and 17 were at level 2. Temporary mechanical assistance was present in 50% of the cohort at LVAD implantation. The 6-month survival/progression to transplant was 92.5%. Average LVAD support time was 385 days (range, 21-1,011 days). RHF developed postoperatively in 13 of 40 patients (32.5%). RHF patients had more severe pre-operative tricuspid incompetence than non-RHF patients. The BTT patients with evidence of RHF had poorer survival to transplant (6 of 11 [54.5%]) than those without RHF (20 of 22 [90.9%]), p = 0.027). There were no other hemodynamic or echocardiographic predictors of short-term RHF. After LVAD, 22 of the 40 patients (55%) thrived clinically. For BTT patients, 20 of 21 (95%) of those who thrived progressed to transplant or were alive at latest follow-up vs 6 of 12 (50%) of those who failed to thrive (FTT; p thrived. Early post-operative RHF results in poorer survival/progression to transplantation for BTT patients and is predicted by greater pre-operative tricuspid incompetence. The most important predictor for those who will clinically thrive longer-term after LVAD insertion is younger age. Crown Copyright © 2011

  19. Network-Assisted Device-to-Device (D2D) Direct Proximity Discovery with Underlay Communication

    DEFF Research Database (Denmark)

    Pratas, Nuno; Popovski, Petar

    2015-01-01

    ) direct communication between proximate devices. While (ii) is treated extensively in the recent literature, (i) has received relatively little attention. In this paper we analyze a network-assisted underlay proximity discovery protocol, where a cellular device can take the role of: announcer (which......Device-to-Device communications are expected to play an important role in current and future cellular generations, by increasing the spatial reuse of spectrum resources and enabling lower latency communication links. This paradigm has two fundamental building blocks: (i) proximity discovery and (ii......, we consider the case where the announcers underlay their messages in the downlink transmissions that are directed towards the monitoring devices. We propose a power control scheme applied to the downlink transmission, which copes with the underlay transmission via additional power expenditure, while...

  20. Left ventricular assist device as destination therapy: application of the payment-by-results approach for the device reimbursement.

    Science.gov (United States)

    Messori, Andrea; Trippoli, Sabrina; Bonacchi, Massimo; Sani, Guido

    2009-08-01

    Value-based methods are increasingly used to reimburse therapeutic innovation, and the payment-by-results approach has been proposed for handling interventions with limited therapeutic evidence. Because most left ventricular assist devices are supported by preliminary efficacy data, we examined the effectiveness data of the HeartMate (Thoratec Corp, Pleasanton, CA) device to explore the application of the payment-by-results approach to these devices and to develop a model for handling reimbursements. According to our model, after establishing the societal economic countervalue for each month of life saved, each patient treated with one such device is associated to the payment of this countervalue for every month of survival lived beyond the final date of estimated life expectancy without left ventricular assist devices. Our base-case analysis, which used the published data of 68 patients who received the HeartMate device, was run with a monthly countervalue of euro 5000, no adjustment for quality of life, and a baseline life expectancy of 150 days without left ventricular assist devices. Sensitivity analysis was aimed at testing the effect of quality of life adjustments and changes in life expectancy without device. In our base-case analysis, the mean total reimbursement per patient was euro 82,426 (range, euro 0 to euro 250,000; N = 68) generated as the sum of monthly payments. This average value was close to the current price of the HeartMate device (euro 75,000). Sensitivity testing showed that the base-case reimbursement of euro 82,426 was little influenced by variations in life expectancy, whereas variations in utility had a more pronounced impact. Our report delineates an innovative procedure for appropriately allocating economic resources in this area of invasive cardiology.

  1. Vocational Reintegration of Handicapped Workers with Assistive Devices

    Science.gov (United States)

    Cooper, N. E.

    1977-01-01

    Two approaches to vocational reintegration of handicapped workers are described: (1) adapting the disabled to the working environment through treatment, therapy, counseling, selective placement, and prostheses, and (2) adapting the working environment to particular handicaps, with the assistive device fitted to the machine or tool rather than to…

  2. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care (Endorsed by the American Heart Association, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie D'intervention).

    Science.gov (United States)

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-06-01

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella®; left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. © 2015 by The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery.

  3. Circulatory Arrest, Brain Arrest and Death Determination

    Directory of Open Access Journals (Sweden)

    Sam David Shemie

    2018-03-01

    Full Text Available Technological advances, particularly in the capacity to support, replace or transplant failing organs, continue to challenge and refine our understanding of human death. Given the ability to reanimate organs before and after death, both inside and outside of the body, through reinstitution of oxygenated circulation, concepts related to death of organs (e.g. cardiac death are no longer valid. This paper advances the rationale for a single conceptual determination of death related to permanent brain arrest, resulting from primary brain injury or secondary to circulatory arrest. The clinical characteristics of brain arrest are the permanent loss of capacity for consciousness and loss of all brainstem functions. In the setting of circulatory arrest, death occurs after the arrest of circulation to the brain rather than death of the heart. Correspondingly, any intervention that resumes oxygenated circulation to the brain after circulatory arrest would invalidate the determination of death.

  4. Circulatory nucleosome levels are significantly increased in early and late-onset preeclampsia.

    Science.gov (United States)

    Zhong, Xiao Yan; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Holzgreve, Wolfgang; Hahn, Sinuhe

    2005-08-01

    Elevations in circulatory DNA, as measured by real-time PCR, have been observed in pregnancies with manifest preeclampsia. Recent reports have indicated that circulatory nucleosome levels are elevated in the periphery of cancer patients. We have now examined whether circulatory nucleosome levels are similarly elevated in cases with preeclampsia. Maternal plasma samples were prepared from 17 cases with early onset preeclampsia (34 weeks gestation) with 10 matched normotensive controls. Levels of circulatory nucleosomes were quantified by commercial ELISA (enzyme-linked immunosorbant assay). The level of circulatory nucleosomes was significantly elevated in both study preeclampsia groups, compared to the matched normotensive control group (p = 0.000 and p = 0.001, respectively). Our data suggests that preeclampsia is associated with the elevated presence of circulatory nucleosomes, and that this phenomenon occurs in both early- and late-onset forms of the disorder. Copyright 2005 John Wiley & Sons, Ltd.

  5. Novel nonsurgical left ventricular assist device and system.

    Science.gov (United States)

    Misiri, Juna; DeSimone, Christopher V; Park, Soon J; Kushwaha, Sudhir S; Friedman, Paul A; Bruce, Charles J; Asirvatham, Samuel J

    2013-01-01

    Treatment options for advanced stages of congestive heart failure remain limited. Left ventricular assist devices (LVADs) have emerged as a means to support failing circulation. However, these devices are not without significant risk such as major open chest surgery. We utilized a novel approach for device placement at the aorto-left atria continuity as a site to create a conduit capable of accommodating a percutaneous LVAD system. We designed and developed an expandable nitinol based device for placement at this site to create a shunt between the LA and aorta. Our experiments support this anatomic location as an accessible and feasible site for accommodation of an entirely percutaneous LVAD. The novelty of this approach would bypass the left ventricle, and thereby minimize complications and morbidities associated with current LVAD placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Impella ventricular support in clinical practice

    DEFF Research Database (Denmark)

    Burzotta, Francesco; Trani, Carlo; Doshi, Sagar N

    2015-01-01

    Mechanical circulatory support represents an evolving field of clinical research and practice. Currently, several cardiac assist devices have been developed but, among different institutions and countries, a large variation in indications for use and device selection exists. The Impella platform...... is an easy to use percutaneous circulatory support device which is increasingly used worldwide. During 2014, we established a working group of European physicians who have collected considerable experience with the Impella device in recent years. By critically comparing the individual experiences...

  7. Our experience with implantation of VentrAssist left ventricular assist device

    Directory of Open Access Journals (Sweden)

    Hiriyur Shivalingappa Jayanthkumar

    2013-01-01

    Full Text Available Perioperative anaesthetic management of the VentrAssist TM left ventricular assist device (LVAD is a challenge for anaesthesiologists because patients presenting for this operation have long-standing cardiac failure and often have associated hepatic and renal impairment, which may significantly alter the pharmacokinetics of administered drugs and render the patients coagulopathic. The VentrAssist is implanted by midline sternotomy. A brief period of cardiopulmonary bypass (CPB for apical cannulation of left ventricle is needed. The centrifugal pump, which produces non-pulsatile, continuous flow, is positioned in the left sub-diaphragmatic pocket. This LVAD is preload dependent and afterload sensitive. Transoesophageal echocardiography is an essential tool to rule out contraindications and to ensure proper inflow cannula position, and following the implantation of LVAD, to ensure right ventricular (RV function. The anaesthesiologist should be prepared to manage cardiac decompensation and acute desaturation before initiation of CPB, as well as RV failure and severe coagulopathic bleeding after CPB. Three patients had undergone implantation of VentrAssist in our hospital. This pump provides flow of 5 l/min depending on preload, afterload and pump speed. All the patients were discharged after an average of 30 days. There was no perioperative mortality.

  8. Structures with Reconfigurable Circulatory Systems

    National Research Council Canada - National Science Library

    Clark, William W; Beckman, Eric J; Cho, Sung K; Weiland, Lisa M; Bielawski, Christopher W

    2008-01-01

    .... One trait that many biological system have that conventional structures do not is a circulatory system, which can be used for many purposes, one of which is the transport of structural material...

  9. Biventricular assist using a portable driver in combination with implanted devices: preliminary experience.

    Science.gov (United States)

    von Segesser, L K; Tkebuchava, T; Leskosek, B; Marty, B; Pei, Y C; Turina, M

    1997-01-01

    Left ventricular assist systems with portable drive units are increasingly used in the clinical setting. However, such systems usually are not suitable for right ventricular support, and therefore, in the case of biventricular heart failure, they must be combined with other support devices that require additional drive consoles. As a result, most of the benefits of the wearable drive units (early mobilization and outpatient care) are lost. This present study was performed to evaluate biventricular support with implanted assist devices and a portable DC/battery-powered driver (Thoratec TLC-II). Electronic control by nonvolatile RAM accessible via RS232 interface, internal backup emergency battery, and optional manual activation are additional features of this 6 kg biventricular drive unit. In 3 bovine experiments (body weight 70 +/- 5 kg) partial cardiopulmonary bypass (CPB) was established, and two ventricular assist devices were implanted into a preperitoneal pocket on each side after connection to the right atrium and the pulmonary artery and to the left atrium and aorta, respectively. After weaning the patient from CPB, activated coagulation time (ACT) was kept at greater than 180 s, and biventricular support with the portable driver was activated. After 10 min, mean device flow stabilized at 3.5 +/- 0 L/min and remained at that level throughout the ensuing 6 h (3.5 +/- 0.3 L/min; NS). The heart rate moved from 130 +/- 13 beats per minute (bpm) at the end of CPB to 116 +/- 13 bpm after 10 min of assist (p < 0.05). Right atrial pressure moved from 11 +/- 2 mm Hg at the end of CPB to 13 +/- 3 mm Hg after 10 min of assist (not significant [NS]). Mean pulmonary artery pressure was 18 +/- mm Hg at the end of CPB and 17 +/- 5 mm Hg after 10 min of assist (NS). Left atrial pressure was 10 +/- 1 mm Hg at the end of CPB and 13 +/- 3 mm Hg after 10 min of assist (NS). Mean aortic pressure was 73 +/- 11 mm Hg at the end of CPB and 77 +/- 3 mm Hg after 10 min of assist (NS

  10. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  11. Monitoring mobility assistive device use in post-stroke patients

    DEFF Research Database (Denmark)

    Boissy, Patrice; Hester, Todd; Sherrill, Delsey

    2007-01-01

    Mobility assistive devices (MAD) such as canes can improve mobility and allow independence in the performance of mobility-related tasks. The use of MAD is often prescribed for stroke survivors. Despite their acknowledged qualities, MAD in real life conditions are typically underutilized, misused...

  12. Magnet-assisted device-level alignment for the fabrication of membrane-sandwiched polydimethylsiloxane microfluidic devices

    International Nuclear Information System (INIS)

    Lu, J-C; Liao, W-H; Tung, Y-C

    2012-01-01

    Polydimethylsiloxane (PDMS) microfluidic device is one of the most essential techniques that advance microfluidics research in recent decades. PDMS is broadly exploited to construct microfluidic devices due to its unique and advantageous material properties. To realize more functionalities, PDMS microfluidic devices with multi-layer architectures, especially those with sandwiched membranes, have been developed for various applications. However, existing alignment methods for device fabrication are mainly based on manual observations, which are time consuming, inaccurate and inconsistent. This paper develops a magnet-assisted alignment method to enhance device-level alignment accuracy and precision without complicated fabrication processes. In the developed alignment method, magnets are embedded into PDMS layers at the corners of the device. The paired magnets are arranged in symmetric positions at each PDMS layer, and the magnetic attraction force automatically pulls the PDMS layers into the aligned position during assembly. This paper also applies the method to construct a practical microfluidic device, a tunable chaotic micromixer. The results demonstrate the successful operation of the device without failure, which suggests the accurate alignment and reliable bonding achieved by the method. Consequently, the fabrication method developed in this paper is promising to be exploited to construct various membrane-sandwiched PDMS microfluidic devices with more integrated functionalities to advance microfluidics research. (paper)

  13. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    Science.gov (United States)

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby

  14. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'intervention.

    Science.gov (United States)

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-05-19

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015 The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Intraoperative bronchoscopic visualization of left ventricular assist device thrombus.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Modi, Sejal; Pappas, Pat; Tatooles, Antone

    2016-07-01

    Despite advancements in left ventricular assist device (LVAD) design and clinical management, device thrombosis remains a pertinent complication. Limited imaging makes precise visualization of clot location and shape very challenging. We report the usage of videobronchoscopic exploration of explanted LVADs for direct visualization of clot in two patients. This technique is a rapid and inexpensive means of improving our understanding of LVAD clot formation and may be useful in surgical exploration of inflow and outflow tracts during LVAD exchange. © The Author(s) 2015.

  16. Endocarditis in left ventricular assist device

    Science.gov (United States)

    Thyagarajan, Braghadheeswar; Kumar, Monisha Priyadarshini; Sikachi, Rutuja R; Agrawal, Abhinav

    2016-01-01

    Summary Heart failure is one of the leading causes of death in developed nations. End stage heart failure often requires cardiac transplantation for survival. The left ventricular assist device (LVAD) has been one of the biggest evolvements in heart failure management often serving as bridge to transplant or destination therapy in advanced heart failure. Like any other medical device, LVAD is associated with complications with infections being reported in many patients. Endocarditis developing secondary to the placement of LVAD is not a frequent, serious and difficult to treat condition with high morbidity and mortality. Currently, there are few retrospective studies and case reports reporting the same. In our review, we found the most common cause of endocarditis in LVAD was due to bacteria. Both bacterial and fungal endocarditis were associated with high morbidity and mortality. In this review we will be discussing the risk factors, organisms involved, diagnostic tests, management strategies, complications, and outcomes in patients who developed endocarditis secondary to LVAD placement. PMID:27672540

  17. Circulatory disease mortality in the Massachusetts tuberculosis fluoroscopy cohort study

    International Nuclear Information System (INIS)

    Little, Mark P.; Zablotska, Lydia B.; Brenner, Alina V.; Lipshultz, Steven E.

    2016-01-01

    High-dose ionizing radiation is associated with circulatory disease. Risks from lower-dose fractionated exposures, such as from diagnostic radiation procedures, remain unclear. In this study we aimed to ascertain the relationship between fractionated low-to-medium dose radiation exposure and circulatory disease mortality in a cohort of 13,568 tuberculosis patients in Massachusetts, some with fluoroscopy screenings, between 1916 and 1961 and follow-up until the end of 2002. Analysis of mortality was in relation to cumulative thyroid (cerebrovascular) or lung (all other circulatory disease) radiation dose via Poisson regression. Over the full dose range, there was no overall radiation-related excess risk of death from circulatory disease (n = 3221; excess relative risk/Gy −0.023; 95 % CI −0.067, 0.028; p = 0.3574). Risk was somewhat elevated in hypertensive heart disease (n = 89; excess relative risk/Gy 0.357; 95 % CI −0.043, 1.030, p = 0.0907) and slightly decreased in ischemic heart disease (n = 1950; excess relative risk/Gy −0.077; 95 % CI −0.130, −0.012; p = 0.0211). However, under 0.5 Gy, there was a borderline significant increasing trend for all circulatory disease (excess relative risk/Gy 0.345; 95 % CI −0.032, 0.764; p = 0.0743) and for ischemic heart disease (excess relative risk/Gy 0.465; 95 % CI, −0.032, 1.034, p = 0.0682). Pneumolobectomy increased radiation–associated risk (excess relative risk/Gy 0.252; 95 % CI 0.024, 0.579). Fractionation of dose did not modify excess risk. In summary, we found no evidence of radiation-associated excess circulatory death risk overall, but there are indications of excess circulatory death risk at lower doses (<0.5 Gy). Although consistent with other radiation-exposed groups, the indications of higher risk at lower doses are unusual and should be confirmed against other data.

  18. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    Science.gov (United States)

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  19. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  20. Transient Characteristics of a Fluidic Device for Circulatory Jet Flow.

    Science.gov (United States)

    Phan, Hoa Thanh; Dinh, Thien Xuan; Bui, Phong Nhu; Dau, Van Thanh

    2018-03-13

    In this paper, we report on the design, simulation, and experimental analysis of a miniaturized device that can generate multiple circulated jet flows. The device is actuated by a lead zirconate titanate (PZT) diaphragm. The flows in the device were studied using three-dimensional transient numerical simulation with the programmable open source OpenFOAM and was comparable to the experimental result. Each flow is verified by two hotwires mounted at two positions inside each consisting chamber. The experiment confirmed that the flow was successfully created, and it demonstrated good agreement with the simulation. In addition, a prospective application of the device as an angular rate sensor is also demonstrated. The device is robust, is minimal in size, and can contribute to the development of multi-axis fluidic inertial sensors, fluidic amplifiers, gas mixing, coupling, and analysis.

  1. Stroke rehabilitation: assistive technology devices and environmental modifications following primary rehabilitation in hospital--a therapeutic perspective

    DEFF Research Database (Denmark)

    Sørensen, Hanne Vinkel; Lendal, Susie; Schultz-Larsen, Kirsten

    2003-01-01

    The aim of this article is to describe the need for assistive devices and environmental modifications among long-living stroke survivors and to investigate if the need is continued and growing over time. The study sample of 155 consecutive stroke patients with stroke-related impairment, discharged...... home from three hospitals in Copenhagen from 1996 through 1998, constituted 20% of the total population of stroke survivors in this area. The results showed that 75% of these patients were provided with assistive devices and/or environmental modifications at discharge. Six months after discharge...... be required in order to target stroke survivors' changing needs for assistive devices and environmental modifications....

  2. Fiber Bragg grating based arterial localization device

    Science.gov (United States)

    Ho, Siu Chun Michael; Li, Weijie; Razavi, Mehdi; Song, Gangbing

    2017-06-01

    A critical first step to many surgical procedures is locating and gaining access to a patients vascular system. Vascular access allows the deployment of other surgical instruments and also the monitoring of many physiological parameters. Current methods to locate blood vessels are predominantly based on the landmark technique coupled with ultrasound, fluoroscopy, or Doppler. However, even with experience and technological assistance, locating the required blood vessel is not always an easy task, especially with patients that present atypical anatomy or suffer from conditions such as weak pulsation or obesity that make vascular localization difficult. With recent advances in fiber optic sensors, there is an opportunity to develop a new tool that can make vascular localization safer and easier. In this work, the authors present a new fiber Bragg grating (FBG) based vascular access device that specializes in arterial localization. The device estimates the location towards a local artery based on the bending of a needle inserted near the tissue surrounding the artery. Experimental results obtained from an artificial circulatory loop and a mock artery show the device works best for lower angles of needle insertion and can provide an approximately 40° range of estimation towards the location of a pulsating source (e.g. an artery).

  3. Internet-Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices

    Science.gov (United States)

    Pron, G; Ieraci, L; Kaulback, K

    2012-01-01

    Executive Summary Objective The objective of this Medical Advisory Secretariat (MAS) report was to conduct a systematic review of the available published evidence on the safety, effectiveness, and cost-effectiveness of Internet-based device-assisted remote monitoring systems (RMSs) for therapeutic cardiac implantable electronic devices (CIEDs) such as pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices. The MAS evidence-based review was performed to support public financing decisions. Clinical Need: Condition and Target Population Sudden cardiac death (SCD) is a major cause of fatalities in developed countries. In the United States almost half a million people die of SCD annually, resulting in more deaths than stroke, lung cancer, breast cancer, and AIDS combined. In Canada each year more than 40,000 people die from a cardiovascular related cause; approximately half of these deaths are attributable to SCD. Most cases of SCD occur in the general population typically in those without a known history of heart disease. Most SCDs are caused by cardiac arrhythmia, an abnormal heart rhythm caused by malfunctions of the heart’s electrical system. Up to half of patients with significant heart failure (HF) also have advanced conduction abnormalities. Cardiac arrhythmias are managed by a variety of drugs, ablative procedures, and therapeutic CIEDs. The range of CIEDs includes pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices. Bradycardia is the main indication for PMs and individuals at high risk for SCD are often treated by ICDs. Heart failure (HF) is also a significant health problem and is the most frequent cause of hospitalization in those over 65 years of age. Patients with moderate to severe HF may also have cardiac arrhythmias, although the cause may be related more to heart pump or haemodynamic failure. The presence of HF, however

  4. Relation between awareness of circulatory disorders and smoking in a general population health examination

    Directory of Open Access Journals (Sweden)

    Völzke Henry

    2006-02-01

    Full Text Available Abstract Background Little is known about proportions of smokers who maintain smoking after they are aware of a circulatory disorder. The goal was to analyze the extent to which the number of circulatory disorders may be related to being a current smoker. Methods Cross-sectional survey study with a probability sample of residents in Germany investigated in health examination centers. Questionnaire data of 3,778 ever smoking participants aged 18 – 79 were used, questions included whether the respondent had ever had hypertension, myocardial infarction, other coronary artery disease, heart failure, stroke, other cerebrovascular disease, peripheral vascular disease, and venous thrombosis. Logistic regression was calculated for circulatory disorders and their number with current smoking as the dependent variable, and odds ratios (OR are presented adjusted for physician contact, inpatient treatment, smoking cessation counseling, heavy smoking, exercise, overweight and obesity, school education, sex and age. Results Among ever smokers who had 1 circulatory disorder, 52.1 % were current smokers and among those who reported that they had 3 or more circulatory disorders 28.0 % were current smokers at the time of the interview. The adjusted odds of being a current smoker were lower for individuals who had ever smoked in life and had 2 or more central circulatory disorders, such as myocardial infarction, heart failure or stroke, than for ever smokers without central circulatory disorder (2 or more disorders: adjusted OR 0.6, 95 % confidence interval, CI, 0.4 to 0.8. Conclusion Among those with central circulatory disorders, there is a substantial portion of individuals who smoke despite their disease. The data suggest that only a portion of smokers among the general population seems to be discouraged from smoking by circulatory disorders or its accompanying cognitive or emotional processes.

  5. Improving hemodynamics of cardiovascular system under a novel intraventricular assist device support via modeling and simulations.

    Science.gov (United States)

    Zhu, Shidong; Luo, Lin; Yang, Bibo; Li, Xinghui; Wang, Xiaohao

    2017-12-01

    Ventricular assist devices (LVADs) are increasingly recognized for supporting blood circulation in heart failure patients who are non-transplant eligible. Because of its volume, the traditional pulsatile device is not easy to implant intracorporeally. Continuous flow LVADs (CF-LVADs) reduce arterial pulsatility and only offer continuous flow, which is different from physiological flow, and may cause long-term complications in the cardiovascular system. The aim of this study was to design a new pulsatile assist device that overcomes this disadvantage, and to test this device in the cardiovascular system. Firstly, the input and output characteristics of the new device were tested in a simple cardiovascular mock system. A detailed mathematical model was established by fitting the experimental data. Secondly, the model was tested in four pathological cases, and was simulated and coupled with a fifth-order cardiovascular system and a new device model using Matlab software. Using assistance of the new device, we demonstrated that the left ventricle pressure, aortic pressure, and aortic flow of heart failure patients improved to the levels of a healthy individual. Especially, in state IV level heart failure patients, the systolic blood pressure increased from 81.34 mmHg to 132.1 mmHg, whereas the diastolic blood pressure increased from 54.28 mmHg to 78.7 mmHg. Cardiac output increased from 3.21 L/min to 5.16 L/min. The newly-developed assist device not only provided a physiological flow that was similar to healthy individuals, but also effectively improved the ability of the pathological ventricular volume. Finally, the effects of the new device on other hemodynamic parameters are discussed.

  6. Impact of interface charge on the electrostatics of field-plate assisted RESURF devices

    NARCIS (Netherlands)

    Boksteen, B.K.; Ferrara, A.; Heringa, A.; Steeneken, P.G.; Hueting, Raymond Josephus Engelbart

    2014-01-01

    A systematic study on the effects of arbitrary parasitic charge profiles, such as trapped or fixed charge, on the 2-D potential distribution in the drain extension of reverse-biased field-plate-assisted reduced surface field (RESURF) devices is presented. Using TCAD device simulations and analytical

  7. Sensor-Based Assistive Devices for Visually-Impaired People: Current Status, Challenges, and Future Directions

    Directory of Open Access Journals (Sweden)

    Wafa Elmannai

    2017-03-01

    Full Text Available The World Health Organization (WHO reported that there are 285 million visuallyimpaired people worldwide. Among these individuals, there are 39 million who are totally blind. There have been several systems designed to support visually-impaired people and to improve the quality of their lives. Unfortunately, most of these systems are limited in their capabilities. In this paper, we present a comparative survey of the wearable and portable assistive devices for visuallyimpaired people in order to show the progress in assistive technology for this group of people. Thus, the contribution of this literature survey is to discuss in detail the most significant devices that are presented in the literature to assist this population and highlight the improvements, advantages, disadvantages, and accuracy. Our aim is to address and present most of the issues of these systems to pave the way for other researchers to design devices that ensure safety and independent mobility to visually-impaired people.

  8. Sensor-Based Assistive Devices for Visually-Impaired People: Current Status, Challenges, and Future Directions

    Science.gov (United States)

    Elmannai, Wafa; Elleithy, Khaled

    2017-01-01

    The World Health Organization (WHO) reported that there are 285 million visually-impaired people worldwide. Among these individuals, there are 39 million who are totally blind. There have been several systems designed to support visually-impaired people and to improve the quality of their lives. Unfortunately, most of these systems are limited in their capabilities. In this paper, we present a comparative survey of the wearable and portable assistive devices for visually-impaired people in order to show the progress in assistive technology for this group of people. Thus, the contribution of this literature survey is to discuss in detail the most significant devices that are presented in the literature to assist this population and highlight the improvements, advantages, disadvantages, and accuracy. Our aim is to address and present most of the issues of these systems to pave the way for other researchers to design devices that ensure safety and independent mobility to visually-impaired people. PMID:28287451

  9. The impact of mobility assistive technology devices on participation for individuals with disabilities.

    Science.gov (United States)

    Carver, Jordan; Ganus, Ashley; Ivey, Jon Mark; Plummer, Teresa; Eubank, Ann

    2016-08-01

    This study aims to address the gap in research and contribute to the body of knowledge on the perspectives assistive technology device users have toward their devices. Mixed methods were used to better understand the impact of mobility assistive technology devices (MATDs) on participation for individuals with disabilities. The Functional Mobility Assessment was administered in conjunction with two qualitative questions developed by the research team allowing participants to expound on the impact of their MATD experience. Participants were recruited online via the National Spinal Cord Injury Association website and in-person at Abilities Expo in Atlanta, Georgia, and the International Seating Symposium in Nashville, Tennessee. Results are consistent with findings from prior research regarding accessibility for individuals with disabilities. Corresponding findings were found in both the quantitative and qualitative data and are categorized into several major themes: environment (indoor and outdoor), surface heights, transportation, dependence, independence, quality of life and participation. Quantitative data from this study indicate that users of MATD are satisfied with the way in which their devices enable maneuvering indoors, while qualitative data suggest otherwise. Implications for healthcare practitioners are described and future recommendations are provided. Implications for Rehabilitation Healthcare professionals should advocate for proper mobility assistive technology devices (MATDs) for their patients in order to enable increased independence, safety and efficiency. Healthcare professionals must be cognizant of the impact of the environment and/or environmental barriers when prescribing MATD. Additional areas of interest for future research may include investigating the impact of MATD in association with date of onset of disability, according to diagnoses, or specific to length of time since acquiring the device.

  10. 14 CFR 382.121 - What mobility aids and other assistive devices may passengers with a disability bring into the...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What mobility aids and other assistive... Aids, and Other Assistive Devices § 382.121 What mobility aids and other assistive devices may... or collapsible wheelchairs; (2) Other mobility aids, such as canes (including those used by persons...

  11. Circulatory mitochondrial DNA is a pro-inflammatory agent in maintenance hemodialysis patients.

    Directory of Open Access Journals (Sweden)

    Hongdi Cao

    Full Text Available Chronic inflammation is highly prevalent in maintenance hemodialysis (MHD patients, and it has been shown to be a strong predictor of morbidity and mortality. Mitochondrial DNA (mtDNA released into circulation after cell damage can promote inflammation in patients and animal models. However, the role and mechanisms of circulatory mtDNA in chronic inflammation in MHD patients remain unknown. Sixty MHD patients and 20 health controls were enrolled in this study. The circulatory mtDNA was detected by quantitative real-time PCR assay. Plasma interleukin 6 (IL-6 and tumor necrosis factor α (TNF-α were quantitated by ELISA assay. Dialysis systems in MHD patients and in vitro were used to evaluate the effect of different dialysis patterns on circulatory mtDNA. Circulatory mtDNA was elevated in MHD patients comparing to that of health control. Regression analysis demonstrated that plasma mtDNA was positively associated with TNF-α and the product of serum calcium and phosphorus, while negatively associated with hemoglobin and serum albumin in MHD patients. MtDNA induced the secretion of IL-6 and TNF-α in the THP-1 cells. Single high-flux hemodialysis (HF-HD and on line hemodiafiltration (OL-HDF but not low-flux hemodialysis (LF-HD could partially reduce plasma mtDNA in MHD patients. In vitro, both HD and hemofiltration (HF could fractional remove mtDNA. Collectively, circulatory mtDNA is elevated and its level is closely correlated with chronic inflammation in MHD patients. HF-HD and HDF can partially reduce circulatory mtDNA in MHD patients.

  12. Intelligent speed adaptation as an assistive device for drivers with acquired brain injury

    DEFF Research Database (Denmark)

    Klarborg, Brith; Lahrmann, Harry Spaabæk; Agerholm, Niels

    2012-01-01

    Intelligent speed adaptation (ISA) was tested as an assistive device for drivers with an acquired brain injury (ABI). The study was part of the “Pay as You Speed” project (PAYS) and used the same equipment and technology as the main study (Lahrmann et al., in press-a, in press-b). Two drivers......, and in general they described driving with ISA as relaxed. ISA reduced the percentage of the total distance that was driven with a speed above the speed limit (PDA), but the subjects relapsed to their previous PDA level in Baseline 2. This suggests that ISA is more suited as a permanent assistive device (i...

  13. Bioartificial liver assist devices in support of patients with liver failure.

    Science.gov (United States)

    Patzer II, John F; Lopez, Roberto C; Zhu, Yue; Wang, Zi-Fa; Mazariegos, George V; Fung, John J

    2002-02-01

    Bioartificial liver assist devices (BALs) offer an opportunity for critical care physicians and transplant surgeons to stabilize patients prior to orthotopic liver transplantation. Such devices may also act as a bridge to transplant, providing liver support to patients awaiting transplant, or as support for patients post living-related donor transplant. Four BAL devices that rely on hepatocytes cultured in hollow fiber membrane cartridges (Circe Biomedical HepatAssist(r), Vitagen ELADTM, Gerlach BELS, and Excorp Medical BLSS) are currently in various stages of clinical evaluation. Comparison of the four devices shows that several unique approaches based upon the same overall system architecture are possible. Preliminary results of the Excorp Medical BLSS Phase I safety evaluation at the University of Pittsburgh, after treating four patients (F, 41, acetominophen-induced, two support periods; M, 50, Wilson's disease, one support period; F, 53, acute alcoholic hepatitis, two support periods; F, 24, chemotherapy-induced, one support period, are presented. All patients presented with hypoglycemia and transient hypotension at the start of extracorporeal perfusion. Hypoglycemia was treated by IV dextrose and the transient hypotension responded positively to IV fluid bolus. Heparin anticoagulation was used only in the second patient. No serious or adverse events were noted in the four patients. Moderate Biochemical response to support was noted in all patients. More complete characterization of the safety of the BLSS requires completion of the Phase I safety evaluation.

  14. Fiber Bragg grating sensor-based communication assistance device

    Science.gov (United States)

    Padma, Srivani; Umesh, Sharath; Pant, Shweta; Srinivas, Talabattula; Asokan, Sundarrajan

    2016-08-01

    Improvements in emergency medicine in the form of efficient life supporting systems and intensive care have increased the survival rate in critically injured patients; however, in some cases, severe brain and spinal cord injuries can result in a locked-in syndrome or other forms of paralysis, and communication with these patients may become restricted or impossible. The present study proposes a noninvasive, real-time communication assistive methodology for those with restricted communication ability, employing a fiber Bragg grating (FBG) sensor. The communication assistive methodology comprises a breath pattern analyzer using an FBG sensor, which acquires the exhalation force that is converted into strain variations on a cantilever. The FBG breath pattern analyzer along with specific breath patterns, which are programmed to give specific audio output commands, constitutes the proposed fiber Bragg grating sensor-based communication assistive device. The basic communication can be carried out by instructing the patients with restricted communication ability to perform the specific breath patterns. The present approach is intended to be an alternative to the common approach of brain-computer interface in which an instrument is utilized for learning of brain responses.

  15. Generation of OH Radical by Ultrasonic Irradiation in Batch and Circulatory Reactor

    Science.gov (United States)

    Fang, Yu; Shimizu, Sayaka; Yamamoto, Takuya; Komarov, Sergey

    2018-03-01

    Ultrasonic technology has been widely investigated in the past as one of the advance oxidation processes to treat wastewater, in this process acoustic cavitation causes generation of OH radical, which play a vital role in improving the treatment efficiency. In this study, OH radical formation rate was measured in batch and circulatory reactor by using Weissler reaction at various ultrasound output power. It is found that the generation rate in batch reactor is higher than that in circulatory reactor at the same output power. The generation rate tended to be slower when output power exceeds 137W. The optimum condition for circulatory reactor was found to be 137W output and 4L/min flow rate. Results of aluminum foil erosion test revealed a strong dependence of cavitation zone length on the ultrasound output power. This is assumed to be one of the reasons why the generation rate of HO radicals becomes slower at higher output power in circulatory reactor.

  16. Design, analysis, and testing of a flexure-based vibration-assisted polishing device

    Science.gov (United States)

    Gu, Yan; Zhou, Yan; Lin, Jieqiong; Lu, Mingming; Zhang, Chenglong; Chen, Xiuyuan

    2018-05-01

    A vibration-assisted polishing device (VAPD) composed of leaf-spring and right-circular flexure hinges is proposed with the aim of realizing vibration-assisted machining along elliptical trajectories. To design the structure, energy methods and the finite-element method are used to calculate the performance of the proposed VAPD. An improved bacterial foraging optimization algorithm is used to optimize the structural parameters. In addition, the performance of the VAPD is tested experimentally. The experimental results indicate that the maximum strokes of the two directional mechanisms operating along the Z1 and Z2 directions are 29.5 μm and 29.3 μm, respectively, and the maximum motion resolutions are 10.05 nm and 10.01 nm, respectively. The maximum working bandwidth is 1,879 Hz, and the device has a good step response.

  17. TongueToSpeech (TTS): Wearable wireless assistive device for augmented speech.

    Science.gov (United States)

    Marjanovic, Nicholas; Piccinini, Giacomo; Kerr, Kevin; Esmailbeigi, Hananeh

    2017-07-01

    Speech is an important aspect of human communication; individuals with speech impairment are unable to communicate vocally in real time. Our team has developed the TongueToSpeech (TTS) device with the goal of augmenting speech communication for the vocally impaired. The proposed device is a wearable wireless assistive device that incorporates a capacitive touch keyboard interface embedded inside a discrete retainer. This device connects to a computer, tablet or a smartphone via Bluetooth connection. The developed TTS application converts text typed by the tongue into audible speech. Our studies have concluded that an 8-contact point configuration between the tongue and the TTS device would yield the best user precision and speed performance. On average using the TTS device inside the oral cavity takes 2.5 times longer than the pointer finger using a T9 (Text on 9 keys) keyboard configuration to type the same phrase. In conclusion, we have developed a discrete noninvasive wearable device that allows the vocally impaired individuals to communicate in real time.

  18. Molecular mechanisms of circulatory dysfunction in cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    Hsin-Ling Ho

    2015-04-01

    Full Text Available Acute or chronic insults to the liver are usually followed by a tissue repairing process. Unfortunately, this action, in most cases, is not effective enough to restore the normal hepatic structure and function. Instead, fibrogenesis and regenerative nodules formation ensue, which are relatively nonfunctioning. The common final stage of the process is liver cirrhosis with increased intrahepatic resistance to portal venous blood flow. Throughout the entire course, the extrahepatic circulatory dysfunction, including increased splanchnic blood flow, elevated portal venous blood flow and pressure, decreased splanchnic and peripheral vascular resistance, tachycardia, and increased cardiac output, are noted and denoted as portal hypertension with hyperdynamic circulatory dysfunction. When such a condition is established, patients may suffer from fatal complications such as gastroesophageal variceal hemorrhage, hepatic encephalopathy, or hepatorenal syndrome. The cause of such a circulatory dysfunction is not fully elucidated. Nevertheless, clarification of the pathophysiology definitely contributes to the control of portal hypertension-related complications. Herein, the molecular mechanism of this intriguing disaster is reviewed and discussed.

  19. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.

    Science.gov (United States)

    Takatani, S; Orime, Y; Tasai, K; Ohara, Y; Naito, K; Mizuguchi, K; Makinouchi, K; Damm, G; Glueck, J; Ling, J

    1994-01-01

    A multipurpose miniature electromechanical energy system has been developed to yield a compact, efficient, durable, and biocompatible total artificial heart (TAH) and ventricular assist device (VAD). Associated controller-driver electronics were recently miniaturized and converted into hybrid circuits. The hybrid controller consists of a microprocessor and controller, motor driver, Hall sensor, and commutation circuit hybrids. The sizing study demonstrated that all these components can be incorporated in the pumping unit of the TAH and VAD, particularly in the centerpiece of the TAH and the motor housing of the VAD. Both TAH and VAD pumping units will start when their power line is connected to either the internal power pack or the external battery unit. As a redundant driving and diagnostic port, an emergency port was newly added and will be placed in subcutaneous location. In case of system failure, the skin will be cut down, and an external motor drive or a pneumatic driver will be connected to this port to run the TAH. This will minimize the circulatory arrest time. Overall efficiency of the TAH without the transcutaneous energy transmission system was 14-18% to deliver pump outputs of 4-9 L/min against the right and left afterload pressures of 25 and 100 mm Hg. The internal power requirement ranged from 6 to 13 W. The rechargeable batteries such as NiCd or NiMH with 1 AH capacity can run the TAH for 30-45 min. The external power requirement, when TETS efficiency of 75% was assumed, ranged from 8 to 18 W. The accelerated endurance test in the 42 degrees C saline bath demonstrated stable performance over 4 months. Long-term endurance and chronic animal studies will continue toward a system with 5 years durability by the year 2000.

  20. De novo development of eosinophilic myocarditis with left ventricular assist device support as bridge to transplant.

    Science.gov (United States)

    Pereira, Naveen L; Park, Soon J; Daly, Richard C; Kushwaha, Sudhir S; Edwards, William D

    2010-10-01

    The de novo development of myocarditis during left ventricular assist device support for dilated cardiomyopathy has not been previously described. We report a case of severe eosinophilic myocarditis associated with the use of leukotriene-receptor antagonist montelukast that developed during left ventricular assist device support accompanied by intra-device thrombus formation that was hemodynamically tolerated and subsequently discovered in the explanted heart. There may be no visible change in cardiac function as assessed by echocardiography, but the diagnosis should be entertained with the development of peripheral eosinophilia. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Cross-cultural adaptation of the assistive technology device - Predisposition assessment (ATD PA) for use in Brazil (ATD PA Br).

    Science.gov (United States)

    Alves, Ana Cristina de Jesus; Matsukura, Thelma Simões; Scherer, Marcia J

    2017-02-01

    The purpose of this study is to conduct a cross-cultural adaptation of the Assistive Technology Device Predisposition Assessment (ATD PA) for use in Brazil. The selection of the Assistive Technology Device Predisposition Assessment (ATD PA) was determined by previous literature reviews of articles published in 2014 and 2016 in six databases with the terms "assistive device" or "assistive technology" or "self-help device" combined with "evidence-based practice" or "framework" or "measurement scale" or "model and outcome assessment". This review indicated that the conceptual model of Assistive Technology (AT) most discussed in the literature was the Matching Person and Technology (MPT) model, and this finding determined the selection of ATD PA as an assessment within the MPT portfolio of measures. The procedures for cross-cultural adaptation were as follows: Equivalence of Concept, Semantic and Operational. Five experts were asked to translate 725 items and these translations were evaluated and a high level of agreement was demonstrated. The Portuguese version, Avaliação de Tecnologia Assistiva - Predisposição ao Uso - ATD PA Br, was derived from the original version in English (ATD PA). The ATD PA Br will support professionals and people with disabilities in Brazil to better select AT devices according to the clients' needs. Implications for rehabilitation Provides a systematic way of selecting assistive technology devices for the use of individuals with disabilities according to the Brazilian reality. A systematic way of selecting the assistive technology that can help decrease the abandonment of the assistive technology use. The use of the Matching Person and Technology theorical model and of the assessment ATD PA Br is essential to guide the researches and clinical practice in Brazil.

  2. A Systematic Review on Existing Measures for the Subjective Assessment of Rehabilitation and Assistive Robot Devices

    Directory of Open Access Journals (Sweden)

    Yiannis Koumpouros

    2016-01-01

    Full Text Available The objective of the current study is to identify and classify outcome measures currently used for the assessment of rehabilitation or assistive robot devices. We conducted a systematic review of the literature using PubMed, MEDLINE, CIRRIE, and Scopus databases for studies that assessed rehabilitation or assistive robot devices from 1980 through January 2016. In all, 31 articles met all inclusion criteria. Tailor-made questionnaires were the most commonly used tool at 66.7%, while the great majority (93.9% of the studies used nonvalidated instruments. The study reveals the absence of a standard scale which makes it difficult to compare the results from different researchers. There is a great need, therefore, for a valid and reliable instrument to be available for use by the intended end users for the subjective assessment of robot devices. The study concludes by identifying two scales that have been validated in general assistive technology devices and could support the scope of subjective assessment in rehabilitation or assistive robots (however, with limited coverage and a new one called PYTHEIA, recently published. The latter intends to close the gap and help researchers and developers to evaluate, assess, and produce products that satisfy the real needs of the end users.

  3. A wound retraction device for laparoscopic-assisted intestinal surgery in dogs and cats.

    Science.gov (United States)

    Gower, Sara B; Mayhew, Philipp D

    2011-06-01

    To report experience with laparoscopic-assisted intestinal resection and anastomosis for treatment of discrete intestinal masses using a novel wound retraction device. Case series. Dogs (n=2) and cats (6). Dogs and cats with discrete intestinal masses identified by ultrasonography without evidence of intestinal perforation or peritonitis, were included. A 2 portal technique was used; 1 portal was enlarged for insertion of the wound retraction device through which the intestine was examined as thoroughly as possible. The diseased portion of the intestine was exteriorized through the wound retractor and resection and anastomosis of the intestinal mass performed. Of the 8 animals, laparoscopic-assisted intestinal resection and anastomosis through the wound retractor was performed in 2 dogs and 3 cats. In 3 cats, based on either location or extent of the lesion, 2 were converted to laparoscopic-assisted intestinal biopsies and 1 to an open colocolostomy. No other intra- or perioperative complications were encountered and all animals survived to discharge. Laparoscopic-assisted intestinal resection and anastomosis can be performed in select canine and feline patients with modestly sized, discrete intestinal masses. © Copyright 2011 by The American College of Veterinary Surgeons.

  4. 49 CFR 39.93 - What wheelchairs and other assistive devices may passengers with a disability bring onto a...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What wheelchairs and other assistive devices may passengers with a disability bring onto a passenger vessel? 39.93 Section 39.93 Transportation Office of the... and Services to Passengers With Disabilities § 39.93 What wheelchairs and other assistive devices may...

  5. Extraction of the Electric Field in Field Plate Assisted RESURF Devices

    NARCIS (Netherlands)

    Boksteen, B.K.; Dhar, S.; Heringa, A.; Koops, G.E.J.; Hueting, Raymond Josephus Engelbart

    2012-01-01

    It has previously been reported that the lateral electric field (Ex) in the drain extension of thin SOI HV (700V) field plate assisted RESURF devices can be extracted from their ID-VD characteristics in the subthreshold regime. In this work the prerequisites for valid field extraction and the

  6. Ab initio assisted process modeling for Si-based nanoelectronic devices

    International Nuclear Information System (INIS)

    Windl, Wolfgang

    2005-01-01

    In this paper, we discuss concepts and examples of ab initio calculations assisting physics-based process simulation. We focus on how to determine diffusion and reaction constants, where modern methods such as the nudged elastic band method allow a systematic and reliable search for the minimum energy migration path and barrier. We show that once the saddle point is determined, the underlying harmonic transition state theory also allows to calculate the prefactors. The discussed examples include nitrogen diffusion, boron deactivation and boron interface segregation. Finally, some concepts are discussed for future device technologies such as molecular devices, where the currently prevalent multiscale approach (kinetic parameters used in higher level models like diffusion-reaction or kinetic Monte Carlo modeling) would not be sensible anymore. As an example, we described the ab initio temperature-accelerated dynamics modeling of contact formation in carbon nanotube devices

  7. Wireless sEMG-Based Body-Machine Interface for Assistive Technology Devices.

    Science.gov (United States)

    Fall, Cheikh Latyr; Gagnon-Turcotte, Gabriel; Dube, Jean-Francois; Gagne, Jean Simon; Delisle, Yanick; Campeau-Lecours, Alexandre; Gosselin, Clement; Gosselin, Benoit

    2017-07-01

    Assistive technology (AT) tools and appliances are being more and more widely used and developed worldwide to improve the autonomy of people living with disabilities and ease the interaction with their environment. This paper describes an intuitive and wireless surface electromyography (sEMG) based body-machine interface for AT tools. Spinal cord injuries at C5-C8 levels affect patients' arms, forearms, hands, and fingers control. Thus, using classical AT control interfaces (keypads, joysticks, etc.) is often difficult or impossible. The proposed system reads the AT users' residual functional capacities through their sEMG activity, and converts them into appropriate commands using a threshold-based control algorithm. It has proven to be suitable as a control alternative for assistive devices and has been tested with the JACO arm, an articulated assistive device of which the vocation is to help people living with upper-body disabilities in their daily life activities. The wireless prototype, the architecture of which is based on a 3-channel sEMG measurement system and a 915-MHz wireless transceiver built around a low-power microcontroller, uses low-cost off-the-shelf commercial components. The embedded controller is compared with JACO's regular joystick-based interface, using combinations of forearm, pectoral, masseter, and trapeze muscles. The measured index of performance values is 0.88, 0.51, and 0.41 bits/s, respectively, for correlation coefficients with the Fitt's model of 0.75, 0.85, and 0.67. These results demonstrate that the proposed controller offers an attractive alternative to conventional interfaces, such as joystick devices, for upper-body disabled people using ATs such as JACO.

  8. Integrating medical, assistive, and universally designed products and technologies: assistive technology device classification (ATDC).

    Science.gov (United States)

    Bauer, Stephen; Elsaesser, Linda-Jeanne

    2012-09-01

    ISO26000:2010 International Guidance Standard on Organizational Social Responsibility requires that effective organizational performance recognize social responsibility, including the rights of persons with disabilities (PWD), engage stakeholders and contribute to sustainable development. Millennium Development Goals 2010 notes that the most vulnerable people require special attention, while the World Report on Disability 2011 identifies improved data collection and removal of barriers to rehabilitation as the means to empower PWD. The Assistive Technology Device Classification (ATDC), Assistive Technology Service Method (ATSM) and Matching Person and Technology models provide an evidence-based, standardized, internationally comparable framework to improve data collection and rehabilitation interventions. The ATDC and ATSM encompass and support universal design (UD) principles, and use the language and concepts of the International Classification of Functioning, Disability and Health (ICF). Use ATDC and ICF concepts to differentiate medical, assistive and UD products and technology; relate technology "types" to markets and costs; and support provision of UD products and technologies as sustainable and socially responsible behavior. Supply-side and demand-side incentives are suggested to foster private sector development and commercialization of UD products and technologies. Health and health-related professionals should be knowledgeable of UD principles and interventions.

  9. Perioperative management of calves undergoing implantation of a left ventricular assist device.

    Science.gov (United States)

    Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J

    2000-01-01

    To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.

  10. [Intelligent operating room suite : From passive medical devices to the self-thinking cognitive surgical assistant].

    Science.gov (United States)

    Kenngott, H G; Wagner, M; Preukschas, A A; Müller-Stich, B P

    2016-12-01

    Modern operating room (OR) suites are mostly digitally connected but until now the primary focus was on the presentation, transfer and distribution of images. Device information and processes within the operating theaters are barely considered. Cognitive assistance systems have triggered a fundamental rethinking in the automotive industry as well as in logistics. In principle, tasks in the OR, some of which are highly repetitive, also have great potential to be supported by automated cognitive assistance via a self-thinking system. This includes the coordination of the entire workflow in the perioperative process in both the operating theater and the whole hospital. With corresponding data from hospital information systems, medical devices and appropriate models of the surgical process, intelligent systems could optimize the workflow in the operating theater in the near future and support the surgeon. Preliminary results on the use of device information and automatically controlled OR suites are already available. Such systems include, for example the guidance of laparoscopic camera systems. Nevertheless, cognitive assistance systems that make use of knowledge about patients, processes and other pieces of information to improve surgical treatment are not yet available in the clinical routine but are urgently needed in order to automatically assist the surgeon in situation-related activities and thus substantially improve patient care.

  11. Mass Transport: Circulatory System with Emphasis on Nonendothermic Species.

    Science.gov (United States)

    Crossley, Dane A; Burggren, Warren W; Reiber, Carl L; Altimiras, Jordi; Rodnick, Kenneth J

    2016-12-06

    Mass transport can be generally defined as movement of material matter. The circulatory system then is a biological example given its role in the movement in transporting gases, nutrients, wastes, and chemical signals. Comparative physiology has a long history of providing new insights and advancing our understanding of circulatory mass transport across a wide array of circulatory systems. Here we focus on circulatory function of nonmodel species. Invertebrates possess diverse convection systems; that at the most complex generate pressures and perform at a level comparable to vertebrates. Many invertebrates actively modulate cardiovascular function using neuronal, neurohormonal, and skeletal muscle activity. In vertebrates, our understanding of cardiac morphology, cardiomyocyte function, and contractile protein regulation by Ca2+ highlights a high degree of conservation, but differences between species exist and are coupled to variable environments and body temperatures. Key regulators of vertebrate cardiac function and systemic blood pressure include the autonomic nervous system, hormones, and ventricular filling. Further chemical factors regulating cardiovascular function include adenosine, natriuretic peptides, arginine vasotocin, endothelin 1, bradykinin, histamine, nitric oxide, and hydrogen sulfide, to name but a few. Diverse vascular morphologies and the regulation of blood flow in the coronary and cerebral circulations are also apparent in nonmammalian species. Dynamic adjustments of cardiovascular function are associated with exercise on land, flying at high altitude, prolonged dives by marine mammals, and unique morphology, such as the giraffe. Future studies should address limits of gas exchange and convective transport, the evolution of high arterial pressure across diverse taxa, and the importance of the cardiovascular system adaptations to extreme environments. © 2017 American Physiological Society. Compr Physiol 7:17-66, 2017. Copyright © 2017 John

  12. The Use of Pediatric Ventricular Assist Devices in Children's Hospitals From 2000 to 2010: Morbidity, Mortality, and Hospital Charges.

    Science.gov (United States)

    Mansfield, Robert T; Lin, Kimberly Y; Zaoutis, Theoklis; Mott, Antonio R; Mohamad, Zeinab; Luan, Xianqun; Kaufman, Beth D; Ravishankar, Chitra; Gaynor, J William; Shaddy, Robert E; Rossano, Joseph W

    2015-07-01

    The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased. A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010. None. Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p < 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1

  13. Inhaled Milrinone After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Haglund, Nicholas A; Burdorf, Adam; Jones, Tara; Shostrom, Valerie; Um, John; Ryan, Timothy; Shillcutt, Sasha; Fischer, Patricia; Cox, Zachary L; Raichlin, Eugenia; Anderson, Daniel R; Lowes, Brian D; Dumitru, Ioana

    2015-10-01

    Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacokinetics (plasma milrinone levels), and cost data were collected.Mean age was 56 ± 9 years, 90% were male, and mean INTERMACS profile was 2.5 ± 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 ± 35.4, 111.3 ± 70.9, 135.9 ± 41.5, 205.0 ± 86.7, 176.8 ± 61.3 187.6 ± 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Blood interaction with a Bioline heparin coated HIA-VAD : A study on calves

    NARCIS (Netherlands)

    vanderKamp, KWHJ; Magielse, CPE; Elstrodt, JM; vanderMeer, J; vanOeveren, W; Rakhorst, G

    The blood compatibility of ventricular assist devices developed by the Helmholtz institute Aachen (HA-VAD's) was tested on calves. Seven calves received a non-coated HIA-VAD (control) and three a Bioline heparin coated device. The circulatory support of these HIA-VAD's lasted one week. Mechanical

  15. Aortic arch reconstruction: deep and moderate hypothermic circulatory arrest with selective antegrade cerebral perfusion.

    Science.gov (United States)

    Wu, YanWen; Xiao, LiQiong; Yang, Ting; Wang, Lei; Chen, Xin

    2017-07-01

    To compare the effects of moderate and deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (SACP) during aortic arch surgery in adult patients and to offer the evidence for the detection of the temperature which provides best brain protection in the subjects who accept aortic arch reconstruction surgery. A total of 109 patients undergoing surgery of the aortic arch were divided into the moderate hypothermic circulatory arrest group (Group I) and the deep hypothermic circulatory arrest group (Group II). We recorded the data of the patients and their cardiopulmonary bypass (CPB) time, aortic clamping time, SACP time and postoperative anesthetized recovery time, tracheal intubation time, time in the intensive care unit (ICU) and postoperative neurologic dysfunction. Patient characteristics were similar in the two groups. There were four patients who died in Group II and 1 patient in Group I. There were no significant differences in aortic clamping time of each group (111.4±58.4 vs. 115.9±16.2) min; SACP time (27.4±5.9 vs. 23.5±6.1) min of the moderate hypothermic circulatory arrest group and the deep hypothermic circulatory arrest group; there were significant differences in cardiopulmonary bypass time (207.4±20.9 vs. 263.8±22.6) min, postoperative anesthetized recovery time (19.0±11.1 vs. 36.8±25.3) hours, extubation time (46.4±15.1 vs. 64.4±6.0) hours; length of stay in the intensive care unit (ICU) (4.7±1.7 vs. 8±2.3) days and postoperative neurologic dysfunction in the two groups. Compared to deep hypothermic circulatory arrest, moderate hypothermic circulatory arrest can provide better brain protection and achieve good clinical results.

  16. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Circulatory Markings at Double-Lane Traffic Roundabout.

    NARCIS (Netherlands)

    Bie, Jing; Lo, Hong K.; Wong, S.C.

    2008-01-01

    This paper compares two types of circulatory markings at a double-lane traffic roundabout: the concentric marking scheme and the Alberta marking scheme. The effects of these two marking schemes on drivers' lane choice behavior, delay, and safety, are compared based on data collected from before and

  18. Modeling Users, Context and Devices for Ambient Assisted Living Environments

    Science.gov (United States)

    Castillejo, Eduardo; Almeida, Aitor; López-de-Ipiña, Diego; Chen, Liming

    2014-01-01

    The participation of users within AAL environments is increasing thanks to the capabilities of the current wearable devices. Furthermore, the significance of considering user's preferences, context conditions and device's capabilities help smart environments to personalize services and resources for them. Being aware of different characteristics of the entities participating in these situations is vital for reaching the main goals of the corresponding systems efficiently. To collect different information from these entities, it is necessary to design several formal models which help designers to organize and give some meaning to the gathered data. In this paper, we analyze several literature solutions for modeling users, context and devices considering different approaches in the Ambient Assisted Living domain. Besides, we remark different ongoing standardization works in this area. We also discuss the used techniques, modeled characteristics and the advantages and drawbacks of each approach to finally draw several conclusions about the reviewed works. PMID:24643006

  19. The use of mobile devices as assistive technology in resource-limited environments: access for learners with visual impairments in Kenya.

    Science.gov (United States)

    Foley, Alan R; Masingila, Joanna O

    2015-07-01

    In this paper, the authors explore the use of mobile devices as assistive technology for students with visual impairments in resource-limited environments. This paper provides initial data and analysis from an ongoing project in Kenya using tablet devices to provide access to education and independence for university students with visual impairments in Kenya. The project is a design-based research project in which we have developed and are refining a theoretically grounded intervention--a model for developing communities of practice to support the use of mobile technology as an assistive technology. We are collecting data to assess the efficacy and improve the model as well as inform the literature that has guided the design of the intervention. In examining the impact of the use of mobile devices for the students with visual impairments, we found that the devices provide the students with (a) access to education, (b) the means to participate in everyday life and (c) the opportunity to create a community of practice. Findings from this project suggest that communities of practice are both a viable and a valuable approach for facilitating the diffusion and support of mobile devices as assistive technology for students with visual impairments in resource-limited environments. Implications for Rehabilitation The use of mobile devices as assistive technology in resource-limited environments provides students with visual impairments access to education and enhanced means to participate in everyday life. Communities of practice are both a viable and a valuable approach for facilitating the diffusion and support of mobile devices as assistive technology for students with visual impairments in resource-limited environments. Providing access to assistive technology early and consistently throughout students' schooling builds both their skill and confidence and also demonstrates the capabilities of people with visual impairments to the larger society.

  20. General surgical complications associated with the use of long-term mechanical circulatory support devices: are we 'under-reporting' problems?

    Science.gov (United States)

    Tchantchaleishvili, Vakhtang; Umakanthan, Ramanan; Karp, Seth; Stulak, John M; Keebler, Mary E; Maltais, Simon

    2013-05-01

    Multiple complications are associated with use of ventricular assist devices (VADs). Cardiac-related complications and infections are most frequently reported. VADs, however, can also lead to a number of general surgical complications equally significant in terms of morbidity and mortality. The authors performed a systematic literature search to review current data that specifically relate general surgical complications to patients who undergo left VAD implantation. The review provides a relatively clear understanding of the spectrum of general surgical complications and shows that they contribute significantly to morbidity and mortality in these patients.

  1. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death—Summary Report*

    Science.gov (United States)

    Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, ; Sonny; Sivarajan, V. Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A.; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D.

    2017-01-01

    Objectives: Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. Methods: We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. Results: We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation

  2. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death-Summary Report.

    Science.gov (United States)

    Weiss, Matthew J; Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, Sonny; Sivarajan, V Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D

    2017-11-01

    Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation after circulatory

  3. Late outcomes of subcostal exchange of the HeartMate II left ventricular assist device: a word of caution.

    Science.gov (United States)

    Yu, Sarah N; Takayama, Hiroo; Han, Jiho; Garan, Arthur R; Kurlansky, Paul; Yuzefpolskaya, Melana; Colombo, Paolo C; Naka, Yoshifumi; Takeda, Koji

    2018-04-10

    Previous studies have shown the usefulness of the subcostal exchange of the HeartMate II left ventricular assist device for device malfunction. However, long-term data are still limited. Between March 2004 and July 2017, 41 of 568 (7.2%) patients who had received a HeartMate II implant at our institution had a device exchange via a subcostal incision. We summarized early and late outcomes. Forty-one patients had a total of 48 subcostal pump exchanges. Indications for device exchange included device thrombosis (n = 31, 76%), driveline infection (n = 2, 5%) and driveline injury (n = 8, 19%). All of the procedures were successful, and there were no in-hospital deaths. A Kaplan-Meier survival curve showed 30-day and 1-year survival rates after subcostal exchange of 100% and 94.6%, respectively. However, 10 (25%) patients had left ventricular assist device-related infections following subcostal exchange that included 7 pump pocket infections and 3 driveline infections. Freedom from left ventricular assist device-related infection at 1 year after subcostal exchange was 79.3%. Thirteen (32%) patients had device malfunction due to pump thrombosis that required a 2nd device exchange. Seven patients had recurrent thrombosis. Three (7%) patients had a stroke. Freedom from device thrombosis and from a stroke event at 1 year was 74.4%. Subcostal pump exchange can be safely performed. However, there is a substantial risk of infection and recurrent thrombosis. Careful follow-up for late complications is mandatory.

  4. 78 FR 49272 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-13

    ... into two types: (1) Devices that provide automatic chest compressions at a fixed compression rate and... circuit is comprised of multiple device types, including, but not limited to, an oxygenator, blood pump... submit a brief statement of the general nature of the evidence or arguments they wish to present, the...

  5. Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables

    NARCIS (Netherlands)

    Ferrari, G.; Kozarski, M.; Gu, Y. J.; De Lazzari, C.; Di Molfetta, A.; Palko, K. J.; Zielinski, K.; Gorczynska, K.; Darowski, M.; Rakhorst, G.

    2008-01-01

    Purpose: Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables. Methods: The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces

  6. Falls and Use of Assistive Devices in Stroke Patients with Hemiparesis: Association with Balance Ability and Fall Efficacy.

    Science.gov (United States)

    Kim, Oksoo; Kim, Jung-Hee

    2015-01-01

    This study investigates balance ability and the fall efficacy with regard to the experiences of stroke patients with hemiparesis. The experience of falling, the use of assistive devices, and each disease-related characteristic were assessed using face-to-face interviews and a self-reported questionnaire. The Berg Balance Scale and Fall Efficacy Scale were used to measure balance ability and confidence. The fall efficacy was significantly lower in participants who had experienced falls than those who had not. The participants who used assistive devices exhibited low balance ability and fall efficacy compared to those who did not use assistive devices. Stroke patients with fall experience and walking aids might be considered at increased risk of falling. Preventive measures for individuals using walking aids may be beneficial in reducing the fall rate of community-dwelling stroke patients. © 2014 Association of Rehabilitation Nurses.

  7. Left ventricular assist device management in patients chronically supported for advanced heart failure.

    Science.gov (United States)

    Cowger, Jennifer; Romano, Matthew A; Stulak, John; Pagani, Francis D; Aaronson, Keith D

    2011-03-01

    This review summarizes management strategies to reduce morbidity and mortality in heart failure patients supported chronically with implantable left ventricular assist devices (LVADs). As the population of patients supported with long-term LVADs has grown, patient selection, operative technique, and patient management strategies have been refined, leading to improved outcomes. This review summarizes recent findings on LVAD candidate selection, and discusses outpatient strategies to optimize device performance and heart failure management. It also reviews important device complications that warrant close outpatient monitoring. Managing patients on chronic LVAD support requires regular patient follow-up, multidisciplinary care teams, and frequent laboratory and echocardiographic surveillance to ensure optimal outcomes.

  8. Right ventricular failure after implantation of a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Cordtz, Johan Joakim; Nilsson, Jens C; Hansen, Peter B

    2014-01-01

    Right ventricular failure (RVF) is a significant complication after implantation of a left ventricular assist device. We aimed to identify haemodynamic changes in the early postoperative phase that predicted subsequent development of RVF in a cohort of HeartMate II (HMII) implanted patients....

  9. An Integrated Simulation Tool for Modeling the Human Circulatory System

    Science.gov (United States)

    Asami, Ken'ichi; Kitamura, Tadashi

    This paper presents an integrated simulation of the circulatory system in physiological movement. The large circulatory system model includes principal organs and functional units in modules in which comprehensive physiological changes such as nerve reflexes, temperature regulation, acid/base balance, O2/CO2 balance, and exercise are simulated. A beat-by-beat heart model, in which the corresponding electrical circuit problems are solved by a numerical analytic method, enables calculation of pulsatile blood flow to the major organs. The integration of different perspectives on physiological changes makes this simulation model applicable for the microscopic evaluation of blood flow under various conditions in the human body.

  10. Embodying prostheses - how to let the body welcome assistive devices. Comment on "The embodiment of assistive devices-from wheelchair to exoskeleton" by M. Pazzaglia and M. Molinari

    Science.gov (United States)

    Longo, Matthew R.; Sadibolova, Renata; Tamè, Luigi

    2016-03-01

    A growing body of research has focused on the development of assistive devises to improve the recovery and ameliorate the quality of life of people suffering from spinal cord injuries (SCI). In their stimulating and timely paper, Pazzaglia and Molinari [1] review the significant progress made by biotechnology studies in providing increasing sophisticated assistive tools (e.g., prostheses and exoskeletons) that extend the functionality of patients' bodies. However, despite this extraordinary technological effort [2], it remains uncertain how these devices can be appropriately embedded into the mental representation of the body. Here, we wish to amplify the points raised by Pazzaglia and Molinari by discussing three challenges facing work on embodying prostheses raised by experimental research on body representation.

  11. Internal vacuum-assisted closure device in the swine model of severe liver injury

    Directory of Open Access Journals (Sweden)

    Everett Christopher B

    2012-12-01

    Full Text Available Abstract Objectives The authors present a novel approach to nonresectional therapy in major hepatic trauma utilizing intraabdominal perihepatic vacuum assisted closure (VAC therapy in the porcine model of Grade V liver injury. Methods A Grade V injury was created in the right lobe of the liver in a healthy pig. A Pringle maneuver was applied (4.5 minutes total clamp time and a vacuum assisted closure device was placed over the injured lobe and connected to suction. The device consisted of a perforated plastic bag placed over the liver, followed by a 15 cm by 15cm VAC sponge covered with a nonperforated plastic bag. The abdomen was closed temporarily. Blood loss, cardiopulmonary parameters and bladder pressures were measured over a one-hour period. The device was then removed and the animal was euthanized. Results Feasibility of device placement was demonstrated by maintenance of adequate vacuum suction pressures and seal. VAC placement presented no major technical challenges. Successful control of ongoing liver hemorrhage was achieved with the VAC. Total blood loss was 625 ml (20ml/kg. This corresponds to class II hemorrhagic shock in humans and compares favorably to previously reported estimated blood losses with similar grade liver injuries in the swine model. No post-injury cardiopulmonary compromise or elevated abdominal compartment pressures were encountered, while hepatic parenchymal perfusion was maintained. Conclusion These data demonstrate the feasibility and utility of a perihepatic negative pressure device for the treatment of hemorrhage from severe liver injury in the porcine model.

  12. Analysis of Dose Response for Circulatory Disease After Radiotherapy for Benign Disease

    Energy Technology Data Exchange (ETDEWEB)

    Little, Mark P., E-mail: mark.little@nih.gov [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States); Kleinerman, Ruth A. [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States); Stovall, Marilyn; Smith, Susan A. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mabuchi, Kiyohiko [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States)

    2012-12-01

    Purpose: To assess the shape of the dose-response for various circulatory disease endpoints, and modifiers by age and time since exposure. Methods and Materials: This was an analysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by circulatory disease endpoint (ischemic heart, cerebrovascular, other circulatory disease). Results: There were significant excess risks for all circulatory disease, with an excess relative risk Gy{sup -1} of 0.082 (95% CI 0.031-0.140), and ischemic heart disease, with an excess relative risk Gy{sup -1} of 0.102 (95% CI 0.039-0.174) (both p = 0.01), and indications of excess risk for stroke. There were no statistically significant (p > 0.2) differences between risks by endpoint, and few indications of curvature in the dose-response. There were significant (p < 0.001) modifications of relative risk by time since exposure, the magnitude of which did not vary between endpoints (p > 0.2). Risk modifications were similar if analysis was restricted to patients receiving radiation, although the relative risks were slightly larger and the risk of stroke failed to be significant. The slopes of the dose-response were generally consistent with those observed in the Japanese atomic bomb survivors and in occupationally and medically exposed groups. Conclusions: There were excess risks for a variety of circulatory diseases in this dataset, with significant modification of risk by time since exposure. The consistency of the dose-response slopes with those observed in radiotherapeutically treated groups at much higher dose, as well as in lower dose-exposed cohorts such as the Japanese atomic bomb survivors and nuclear workers, implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.

  13. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    Science.gov (United States)

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  14. Hybrid approach of ventricular assist device and autologous bone marrow stem cells implantation in end-stage ischemic heart failure enhances myocardial reperfusion

    Directory of Open Access Journals (Sweden)

    Khayat Andre

    2011-01-01

    Full Text Available Abstract We challenge the hypothesis of enhanced myocardial reperfusion after implanting a left ventricular assist device together with bone marrow mononuclear stem cells in patients with end-stage ischemic cardiomyopathy. Irreversible myocardial loss observed in ischemic cardiomyopathy leads to progressive cardiac remodelling and dysfunction through a complex neurohormonal cascade. New generation assist devices promote myocardial recovery only in patients with dilated or peripartum cardiomyopathy. In the setting of diffuse myocardial ischemia not amenable to revascularization, native myocardial recovery has not been observed after implantation of an assist device as destination therapy. The hybrid approach of implanting autologous bone marrow stem cells during assist device implantation may eventually improve native cardiac function, which may be associated with a better prognosis eventually ameliorating the need for subsequent heart transplantation. The aforementioned hypothesis has to be tested with well-designed prospective multicentre studies.

  15. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Assistive devices alter gait patterns in Parkinson disease: advantages of the four-wheeled walker.

    Science.gov (United States)

    Kegelmeyer, Deb A; Parthasarathy, Sowmya; Kostyk, Sandra K; White, Susan E; Kloos, Anne D

    2013-05-01

    Gait abnormalities are a hallmark of Parkinson's disease (PD) and contribute to fall risk. Therapy and exercise are often encouraged to increase mobility and decrease falls. As disease symptoms progress, assistive devices are often prescribed. There are no guidelines for choosing appropriate ambulatory devices. This unique study systematically examined the impact of a broad range of assistive devices on gait measures during walking in both a straight path and around obstacles in individuals with PD. Quantitative gait measures, including velocity, stride length, percent swing and double support time, and coefficients of variation were assessed in 27 individuals with PD with or without one of six different devices including canes, standard and wheeled walkers (two, four or U-Step). Data were collected using the GAITRite and on a figure-of-eight course. All devices, with the exception of four-wheeled and U-Step walkers significantly decreased gait velocity. The four-wheeled walker resulted in less variability in gait measures and had less impact on spontaneous unassisted gait patterns. The U-Step walker exhibited the highest variability across all parameters followed by the two-wheeled and standard walkers. Higher variability has been correlated with increased falls. Though subjects performed better on a figure-of-eight course using either the four-wheeled or the U-Step walker, the four-wheeled walker resulted in the most consistent improvement in overall gait variables. Laser light use on a U-Step walker did not improve gait measures or safety in figure-of-eight compared to other devices. Of the devices tested, the four-wheeled-walker offered the most consistent advantages for improving mobility and safety. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  18. A Numerical Analysis of Phononic-Assisted Control of Ultrasound Waves in Acoustofluidic Device

    DEFF Research Database (Denmark)

    Moiseyenko, Rayisa; Bruus, Henrik

    2015-01-01

    and streaming has received much attention, since it relies solely on mechanical properties such as particle size and contrast in density and compressibility. We present a theoretical study of phononic-assisted control of ultrasound waves in acoustofluidic devices. We propose the use of phononic crystal...... diffractors, which can be introduced in acoustofluidic structures. These diffractors can be applied in the design of efficient resonant cavities, directional sound waves for new types of particle sorting methods, or acoustically controlled deterministic lateral displacement. The PnC-diffractor-based devices...... can be made configurable, by embedding the diffractors, all working at the same excitation frequency but with different resulting diffraction patterns, in exchangeable membranes on top of the device....

  19. Loose-Lipped Mobile Device Intelligent Personal Assistants: A Discussion of Information Gleaned from Siri on Locked iOS Devices.

    Science.gov (United States)

    Horsman, Graeme

    2018-04-23

    The forensic analysis of mobile handsets is becoming a more prominent factor in many criminal investigations. Despite such devices frequently storing relevant evidential content to support an investigation, accessing this information is becoming an increasingly difficult task due to enhanced effective security features. Where access to a device's resident data is not possible via traditional mobile forensic methods, in some cases it may still be possible to extract user information via queries made to an installed intelligent personal assistant. This article presents an evaluation of the information which is retrievable from Apple's Siri when interacted with on a locked iOS device running iOS 11.2.5 (the latest at the time of testing). The testing of verbal commands designed to elicit a response from Siri demonstrate the ability to recover call log, SMS, Contacts, Apple Maps, Calendar, and device information which may support any further investigation. © 2018 American Academy of Forensic Sciences.

  20. The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device.

    Science.gov (United States)

    Schönberger, Markus; Deutsch, Steven; Manning, Keefe B

    2012-01-01

    Ventricular assist devices are a commonly used heart failure therapy for adult patients as bridge-to-transplant or bridge-to-recovery tools. The application of adult ventricular assist devices in pediatric patients has led to increased thrombotic events. Therefore, we have been developing a pediatric ventricular assist device (PVAD), the Penn State 12 cc PVAD. It is designed for patients with a body weight of 5-15 kg and has a stroke volume of 12 cc. Clot formation is the major concern. It is correlated to the coagulability of blood, the blood contacting materials and the fluid dynamics within the system. The intent is for the PVAD to be a long term therapy. Therefore, the system may be oriented in different positions according to the patient's behavior. This study evaluates for the first time the impact of position on the flow patterns within the Penn State 12 cc PVAD, which may help to improve the PVAD design concerning chamber and ports geometries. The fluid dynamics are visualized by particle image velocimetry. The evaluation is based on inlet jet behavior and calculated wall shear rates. Vertical and horizontal model orientations are compared, both with a beat rate of 75, outlet pressures of 90/60 mm Hg and a flow rate of 1.3 l/min. The results show a significant change of the inlet jet behavior and the development of a rotational flow pattern. Vertically, the inlet jet is strong along the wall. It initiates a rotational flow pattern with a wandering axis of rotation. In contrast, the horizontal model orientation results show a weaker inlet jet along the wall with a nearly constant center of rotation location, which can be correlated to a higher risk of thrombotic events. In addition, high speed videography illustrates differences in the diaphragm motion during diastole. Diaphragm opening trajectories measurements determine no significant impact of the density of the blood analog fluids. Hence, the results correlate to human blood.

  1. Developing an Anti-Xa-Based Anticoagulation Protocol for Patients with Percutaneous Ventricular Assist Devices.

    Science.gov (United States)

    Sieg, Adam; Mardis, B Andrew; Mardis, Caitlin R; Huber, Michelle R; New, James P; Meadows, Holly B; Cook, Jennifer L; Toole, J Matthew; Uber, Walter E

    2015-01-01

    Because of the complexities associated with anticoagulation in temporary percutaneous ventricular assist device (pVAD) recipients, a lack of standardization exists in their management. This retrospective analysis evaluates current anticoagulation practices at a single center with the aim of identifying an optimal anticoagulation strategy and protocol. Patients were divided into two cohorts based on pVAD implanted (CentriMag (Thoratec; Pleasanton, CA) / TandemHeart (CardiacAssist; Pittsburgh, PA) or Impella (Abiomed, Danvers, MA)), with each group individually analyzed for bleeding and thrombotic complications. Patients in the CentriMag/TandemHeart cohort were subdivided based on the anticoagulation monitoring strategy (activated partial thromboplastin time (aPTT) or antifactor Xa unfractionated heparin (anti-Xa) values). In the CentriMag/TandemHeart cohort, there were five patients with anticoagulation titrated based on anti-Xa values; one patient developed a device thrombosis and a major bleed, whereas another patient experienced major bleeding. Eight patients received an Impella pVAD. Seven total major bleeds in three patients and no thrombotic events were detected. Based on distinct differences between the devices, anti-Xa values, and outcomes, two protocols were created to guide anticoagulation adjustments. However, anticoagulation in patients who require pVAD support is complex with constantly evolving anticoagulation goals. The ideal level of anticoagulation should be individually determined using several coagulation laboratory parameters in concert with hemodynamic changes in the patient's clinical status, the device, and the device cannulation.

  2. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  3. External validation of prediction models for time to death in potential donors after circulatory death

    NARCIS (Netherlands)

    Kotsopoulos, A.M.M.; Böing-Messing, F.; Jansen, N.E.; Vos, P.; Abdo, W.F.

    2018-01-01

    Predicting time to death in controlled donation after circulatory death (cDCD) donors following withdrawal of life‐sustaining treatment (WLST) is important but poses a major challenge. The aim of this study is to determine factors predicting time to circulatory death within 60 minutes after WSLT and

  4. PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach.

    Science.gov (United States)

    Antaki, James F; Ricci, Michael R; Verkaik, Josiah E; Snyder, Shaun T; Maul, Timothy M; Kim, Jeongho; Paden, Dave B; Kameneva, Marina V; Paden, Bradley E; Wearden, Peter D; Borovetz, Harvey S

    2010-03-01

    This report describes a multi-disciplinary program to develop a pediatric blood pump, motivated by the critical need to treat infants and young children with congenital and acquired heart diseases. The unique challenges of this patient population require a device with exceptional biocompatibility, miniaturized for implantation up to 6 months. This program implemented a collaborative, prescriptive design process, whereby mathematical models of the governing physics were coupled with numerical optimization to achieve a favorable compromise among several competing design objectives. Computational simulations of fluid dynamics, electromagnetics, and rotordynamics were performed in two stages: first using reduced-order formulations to permit rapid optimization of the key design parameters; followed by rigorous CFD and FEA simulations for calibration, validation, and detailed optimization. Over 20 design configurations were initially considered, leading to three pump topologies, judged on the basis of a multi-component analysis including criteria for anatomic fit, performance, biocompatibility, reliability, and manufacturability. This led to fabrication of a mixed-flow magnetically levitated pump, the PF3, having a displaced volume of 16.6 cc, approximating the size of a AA battery and producing a flow capacity of 0.3-1.5 L/min. Initial in vivo evaluation demonstrated excellent hemocompatibility after 72 days of implantation in an ovine. In summary, combination of prescriptive and heuristic design principles have proven effective in developing a miniature magnetically levitated blood pump with excellent performance and biocompatibility, suitable for integration into chronic circulatory support system for infants and young children; aiming for a clinical trial within 3 years.

  5. Laparoscopy-assisted percutaneous endoscopic gastrostomy using a "Funada-kit II" device.

    Science.gov (United States)

    Takahashi, Toshiaki; Miyano, Go; Shiyanagi, Satoko; Lane, Geoffrey J; Yamataka, Atsuyuki

    2012-09-01

    We aimed at assessing the effect of using a "Funada-kit II" device during laparoscopy-assisted percutaneous endoscopic gastrostomy (Lap-PEG), by reviewing 29 cases of Lap-PEG we performed from 2001 to 2011. We started using the "Funada-kit II" (CREATE MEDIC CO., Kanagawa, Japan) device with two parallel needles to puncture the stomach and assist suturing the anterior gastric wall to the anterior abdominal wall during Lap-PEG in 2011 (F-PEG). By introducing a loop through the lumen of one needle which allows placement of a suture introduced through the lumen of the other needle. Once repeated, the stomach can be pexied at two points, approximately 2 cm apart. We compared Lap-PEG (n = 23) with F-PEG (n = 6) where the mean ages and weights at surgery and sex ratios were similar. All cases were uneventful without intraoperative complications, although one postoperative wound infection occurred in a Lap-PEG case. There were no differences in the duration of analgesia, time taken to commence tube feeding, and return to full feeding. However, mean operating time was significantly shorter in F-PEG (28.1 min) versus Lap-PEG (46.1 min) p < 0.05. As per results F-PEG would appear to be as safe as Lap-PEG, but much quicker.

  6. Older individuals' experiences during the assistive technology device service delivery process.

    Science.gov (United States)

    Gramstad, Astrid; Storli, Sissel Lisa; Hamran, Torunn

    2014-07-01

    Providing assistive technology devices to older individuals living in their ordinary homes is an important intervention to increase and sustain independence and to enable ageing at home. However, little is known about older individuals' experiences and needs in the assistive technology device (ATD) service delivery process. The purpose of this study was to investigate older individuals' experiences during the service delivery process of ATDs. Nine older individuals were interviewed three times each throughout the ATD service delivery process. The interviews were analysed within a hermeneutical phenomenological perspective. The results show that the service delivery process could be interpreted as an enigmatic journey and described using four themes: "hope and optimistic expectations", "managing after delivery or needing additional help", "having available help versus being abandoned", and "taking charge or putting up". The results emphasize the need for occupational therapists to maintain an individualized approach towards older clients throughout the service delivery process. The experiences of older individuals were diverse and related to expectations that were not necessarily articulated to the occupational therapist. The situation when the ATD is delivered to the client was highlighted by the clients as an important event with the potential to facilitate a successful service delivery process.

  7. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study.

    Science.gov (United States)

    Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo

    2018-05-22

    Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

  8. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  9. Bridge to recovery in two cases of dilated cardiomyopathy after long-term mechanical circulatory support.

    Science.gov (United States)

    Pacholewicz, Jerzy; Zakliczyński, Michał; Kowalik, Violetta; Nadziakiewicz, Paweł; Kowalski, Oskar; Kalarus, Zbigniew; Zembala, Marian

    2014-06-01

    Ventricular assist devices (VADs) have become an established therapeutic option for patients with end-stage heart failure. Achieving the potential for recovery of native heart function using VADs is an established form of treatment in a selected group of patients with HF. We report two cases of VAD patients with different types of pump used for mechanical circulatory support, a continuous flow pump (Heart-Ware(®)) and a pulsatile pump (POLVAD MEV(®)), which allow regeneration of the native heart. Patients were qualified as INTERMACS level 3-4 for elective implantation of an LVAD. Implantations were performed without complications. The postoperative course was uncomplicated. In the HeartWare patient the follow-up was complicated by episodes of epistaxis and recurrent GIB as well as driveline infection. The follow-up of the POLVAD MEV patient was uneventful. Recurrent GIB forced us to withdraw aspirin and warfarin therapy and maintain only clopidogrel in the HeartWare patient.. In mid-February 2013 the patient was admitted due to dysfunction of the centrifugal pump with a continuous low-flow alarm and increase power consumption. Under close monitoring of the patient a decision was made to stop the pump immediately and evaluate cardiac function. The serial echocardiography studies showed significant improvement in LVEF up to 45% and no significant valvular pathology. In February 2013 LVAD explant was performed by left thoracotomy without complications. At six-month follow-up the patient was in a good clinical condition, in NYHA class I/II, and on pharmacological treatment.

  10. Sizable variations in circulatory disease mortality by region and country of birth in six European countries

    DEFF Research Database (Denmark)

    Rafnsson, Snorri B; Bhopal, Raj S; Agyemang, Charles

    2013-01-01

    BACKGROUND: Circulatory disease mortality inequalities by country of birth (COB) have been demonstrated for some EU countries but pan-European analyses are lacking. We examine inequalities in circulatory mortality by geographical region/COB for six EU countries. METHODS: We obtained national deat...

  11. Scandinavian SSAI clinical practice guideline on choice of first-line vasopressor for patients with acute circulatory failure

    DEFF Research Database (Denmark)

    Møller, M H; Claudius, C; Junttila, E

    2016-01-01

    BACKGROUND: Adult critically ill patients often suffer from acute circulatory failure, necessitating use of vasopressor therapy. The aim of the Scandinavian Society of Anaesthesiology and Intensive Care Medicine (SSAI) task force for Acute Circulatory Failure was to present clinically relevant...... to recommendations. We assessed the following subpopulations of patients with acute circulatory failure: 1) shock in general, 2) septic shock, 3) cardiogenic shock, 4) hypovolemic shock and 5) other types of shock, including vasodilatory shock. We assessed patient-important outcome measures, including mortality...

  12. A cause of circulatory collapse that should be considered following trauma

    Directory of Open Access Journals (Sweden)

    Omar Hesham R

    2010-08-01

    Full Text Available Abstract Management of poly-trauma patients presenting to the emergency room is usually a challenging and formidable task. Two of the common problems seen in those patients are shock and neurological dysfunction. A huge differential for post-traumatic circulatory collapse exist and timely identification of the etiology is of utmost importance to avoid complications. In this report we are describing 2 cases presenting with circulatory collapse following trauma. The first case was a 29 year old female who presented after a motor vehicle accident fully conscious with severe hypotension and bradycardia. The second case presented with severe hemodynamic instability after falling at home. Physical examination of both patients revealed weakness in all 4 limbs and CT cervical spine revealed complete anterior sublaxation of C5 over C6 cervical vertebrae in the first case and partial sublaxation of C5 over C6 cervical vertebrae in the second case confirming that spinal cord injury is the likely cause for these hemodynamic alterations. A high index of suspicion for spinal cord injuries is therefore mandatory when managing a trauma patient presenting with quadriparesis and hemodynamic instability that is otherwise unexplained especially when the ensuing hypotension is associated with bradycardia instead of reflex tachycardia. Awareness of this cause of circulatory collapse is particularly important in the unconscious patient where eliciting sensory and motor deficits looking for spinal cord injury is not always feasible. Both patients were transferred to the intensive care unit and were maintained on epinephrine till becoming hemodynamically stable. The report aims to sensitize readers to this cause of post-traumatic circulatory collapse.

  13. Transplantation of Hearts Donated after Circulatory Death

    Directory of Open Access Journals (Sweden)

    Christopher W. White

    2018-02-01

    Full Text Available Cardiac transplantation has become limited by a critical shortage of suitable organs from brain-dead donors. Reports describing the successful clinical transplantation of hearts donated after circulatory death (DCD have recently emerged. Hearts from DCD donors suffer significant ischemic injury prior to organ procurement; therefore, the traditional approach to the transplantation of hearts from brain-dead donors is not applicable to the DCD context. Advances in our understanding of ischemic post-conditioning have facilitated the development of DCD heart resuscitation strategies that can be used to minimize ischemia-reperfusion injury at the time of organ procurement. The availability of a clinically approved ex situ heart perfusion device now allows DCD heart preservation in a normothermic beating state and minimizes exposure to incremental cold ischemia. This technology also facilitates assessments of organ viability to be undertaken prior to transplantation, thereby minimizing the risk of primary graft dysfunction. The application of a tailored approach to DCD heart transplantation that focuses on organ resuscitation at the time of procurement, ex situ preservation, and pre-transplant assessments of organ viability has facilitated the successful clinical application of DCD heart transplantation. The transplantation of hearts from DCD donors is now a clinical reality. Investigating ways to optimize the resuscitation, preservation, evaluation, and long-term outcomes is vital to ensure a broader application of DCD heart transplantation in the future.

  14. Physical interface dynamics alter how robotic exosuits augment human movement: implications for optimizing wearable assistive devices.

    Science.gov (United States)

    Yandell, Matthew B; Quinlivan, Brendan T; Popov, Dmitry; Walsh, Conor; Zelik, Karl E

    2017-05-18

    Wearable assistive devices have demonstrated the potential to improve mobility outcomes for individuals with disabilities, and to augment healthy human performance; however, these benefits depend on how effectively power is transmitted from the device to the human user. Quantifying and understanding this power transmission is challenging due to complex human-device interface dynamics that occur as biological tissues and physical interface materials deform and displace under load, absorbing and returning power. Here we introduce a new methodology for quickly estimating interface power dynamics during movement tasks using common motion capture and force measurements, and then apply this method to quantify how a soft robotic ankle exosuit interacts with and transfers power to the human body during walking. We partition exosuit end-effector power (i.e., power output from the device) into power that augments ankle plantarflexion (termed augmentation power) vs. power that goes into deformation and motion of interface materials and underlying soft tissues (termed interface power). We provide empirical evidence of how human-exosuit interfaces absorb and return energy, reshaping exosuit-to-human power flow and resulting in three key consequences: (i) During exosuit loading (as applied forces increased), about 55% of exosuit end-effector power was absorbed into the interfaces. (ii) However, during subsequent exosuit unloading (as applied forces decreased) most of the absorbed interface power was returned viscoelastically. Consequently, the majority (about 75%) of exosuit end-effector work over each stride contributed to augmenting ankle plantarflexion. (iii) Ankle augmentation power (and work) was delayed relative to exosuit end-effector power, due to these interface energy absorption and return dynamics. Our findings elucidate the complexities of human-exosuit interface dynamics during transmission of power from assistive devices to the human body, and provide insight into

  15. Biological evaluation of mechanical circulatory support systems in calves

    NARCIS (Netherlands)

    Rakhorst, G; VanDerMeer, J; Kik, C; Mihaylov, D; Havlik, P; Trinkl, J; Monties, [No Value

    Data from animal experiments with mechanical circulatory support systems (MCSS) performed in Groningen and Marseille over the past years were used to obtain normal values of hematological, coagulation, rheological and blood chemistry parameters in calves. These parameters were divided between two

  16. Utilization of assistive devices for students with disabilities in the public schools

    Directory of Open Access Journals (Sweden)

    Carolina Bastos Plotegher

    2013-04-01

    Full Text Available Introduction: Assistive technology is an area of expanding knowledge in Brazil. Its use in school can help students with disabilities in performing important tasks to participate in different activities. Objectives: to report the experience of using assistive devices in the academic achievement of students with disabilities included in the regular school system of the municipality of Sao Carlos, state of Sao Paulo. Method: it was developed from an extension project conducted in 2010. Thirteen students with various types of disabilities participated in the project. The interventions were based on the School Function Assessment with the teachers to know the students’ difficulties. The students were also observed performing school tasks. Results: Forty-seven adaptations were made: thickeners, rings for zippers, slants, communication boards, non-slip mats, among others. Besides the adjustments, orientation regarding use of the devices was provided for teachers and persons responsible for the students. Conclusion: we believe that the project benefited the students, because it produced higher academic achievement and provided better school conditions for their school inclusion. For the undergraduate students of Occupational Therapy, the project enabled the dealing with real issues of inclusion and school interventions, thus approaching theory to practice.

  17. The Ventricular Assist Device in the Life of the Child: A Phenomenological Pediatric Study.

    Science.gov (United States)

    van Manen, Michael A

    2017-05-01

    What is it like for a child to live with an artificial heart? The use of some medical therapies in children requires developmental considerations, is associated with psychosocial consequences, and calls for ethical sensitivities. A critical case is the ventricular assist device (VAD), a mechanical pump used to support the functioning of a failing heart. As a pediatric therapy, the device can be used as a temporary solution for poor heart function, a bridge to transplantation or recovery, or as a destination therapy. While the mechanical-technical operation of the VAD is well understood, the clinical-technical aspects of young people living with this device are largely unexplored. Drawing on interviews of school-aged children, the aim of this phenomenological study is to explore how a VAD may structure or condition a child's meaningful experience of their world outside the hospital. The driveline of an implanted VAD is the peripheral attachment, extruding through the skin to connect the controller-power supply. The materiality of the device may be interruptive, restrictive, and disturbing to the psycho-physical being and sense of self-identity of the child as a child. And while a child equipped with a VAD is not necessarily conspicuous among other children, the child may experience the device as an exposing presence, while living with the worry of a caregiver who takes on the role not simply of parent but of watchful health professional. A phenomenological understanding of the VAD should assist parents and caregiving health professionals knowing how to deal with specific issues arising in the life of the VAD child.

  18. Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach.

    Science.gov (United States)

    Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel

    2014-09-01

    Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow

  19. Evolution of general surgical problems in patients with left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient

  20. Early Identification of Circulatory Shock in Critical Care Transport

    Science.gov (United States)

    2008-09-30

    disclosure and community consultation. Early Identification of Circulatory Shock in Critical Care Transport 2 Community consultation for this...in two aircraft types (Eurocopter EC 135 and EC 145), in IFR weather conditions, and during both day and night operations. We calculated the

  1. Multicenter Evaluation of Octreotide as Secondary Prophylaxis in Patients With Left Ventricular Assist Devices and Gastrointestinal Bleeding.

    Science.gov (United States)

    Shah, Keyur B; Gunda, Sampath; Emani, Sitaramesh; Kanwar, Manreet K; Uriel, Nir; Colombo, Paolo C; Uber, Patricia A; Sears, Melissa L; Chuang, Joyce; Farrar, David J; Brophy, Donald F; Smallfield, George B

    2017-11-01

    Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. This multicenter, retrospective analysis evaluated 51 continuous-flow left ventricular assist device patients who received secondary prophylaxis with octreotide after their index GI bleed from 2009 to 2015. All patients had a hospitalization for GI bleed and received octreotide after discharge. Patient demographics, medical and medication history, and clinical characteristics of patients who rebled after receiving octreotide were compared with non-rebleeders. These data were also compared with matched historical control patients previously enrolled in the HMII (HeartMate II) clinical trials, none of whom received octreotide, to provide a context for the bleeding rates. Twelve patients (24%) who received secondary octreotide prophylaxis developed another GI bleed, whereas 39 (76%) did not. There were similar intergroup demographics; however, significantly more bleeders had a previous GI bleeding history before left ventricular assist device placement (33% versus 5%; P =0.02) and greater frequency of angiodysplasia confirmed during endoscopy (58% versus 23%; P =0.03). Fewer patients in this study experienced a recurrent GI bleed compared with a matched historical control group that did not receive octreotide (24% versus 43%; P =0.04). Patients with continuous-flow left ventricular assist device receiving secondary prophylaxis with octreotide had a significantly lower GI bleed recurrence compared with historical controls not treated with octreotide. Additional prospective studies are needed to confirm these data. © 2017 American Heart Association, Inc.

  2. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    Science.gov (United States)

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  3. Interacting with and via mobile devices and mobile robots in an assisted living setting

    Directory of Open Access Journals (Sweden)

    Maria Dagioglou

    2015-05-01

    Full Text Available Using robotic home assistants as a platform for remote health monitoring offers several advantages, but also presents considerable challenges related to both the technical immaturity of home robotics and to user acceptance issues. In this paper we explore tablets and similar mobile devices as the medium of communication between robots and their users, presenting relevant current and planned research in humanrobot interaction that can help the telehealth community circumvent technical shortcomings, improve user acceptance, and maximize the quality of the data collected by robotic home assistants.

  4. Network-Assisted Distributed Fairness-Aware Interference Coordination for Device-to-Device Communication Underlaid Cellular Networks

    Directory of Open Access Journals (Sweden)

    Francis Boabang

    2017-01-01

    Full Text Available Device-to-device (D2D communication underlaid cellular network is considered a key integration feature in future cellular network. However, without properly designed interference management, the interference from D2D transmission tends to degrade the performance of cellular users and D2D pairs. In this work, we proposed a network-assisted distributed interference mitigation scheme to address this issue. Specifically, the base station (BS acts as a control agent that coordinates the cross-tier interference from D2D transmission through a taxation scheme. The cotier interference is controlled by noncooperative game amongst D2D pairs. In general, the outcome of noncooperative game is inefficient due to the selfishness of each player. In our game formulation, reference user who is the victim of cotier interference is factored into the payoff function of each player to obtain fair and efficient outcome. The existence, uniqueness of the Nash Equilibrium (NE, and the convergence of the proposed algorithm are characterized using Variational Inequality theory. Finally, we provide simulation results to evaluate the efficiency of the proposed algorithm.

  5. A novel vibration assisted polishing device based on the flexural mechanism driven by the piezoelectric actuators

    Directory of Open Access Journals (Sweden)

    Guilian Wang

    2018-01-01

    Full Text Available The vibration assisted polishing has widely application fields because of higher machining frequency and better polishing quality, especially the polishing with the non-resonant mode that is regarded as a kind of promising polishing method. This paper reports a novel vibration assisted polishing device, consisting of the flexible hinge mechanism driven by the piezoelectric actuators, which is suitable for polishing planes or curve surfaces with slow curvature. Firstly, the generation methods of vibration trajectory are investigated for the same frequency and different frequency signals’ inputs, respectively, and then the types of elliptic and Lissajous’s vibration trajectories are generated respectively. Secondly, a flexural mechanism consisting of the right circular flexible hinges and the leaf springs is developed to produce two-dimensional vibration trajectory. Statics and dynamics investigating of this flexible mechanism are finished in detail. The analytical models about input and output compliances of the flexural mechanism are established according to the matrix-based compliance modeling, and the dynamic model of the flexural mechanism based on the Euler-Lagrange equation is also presented. The finite element model of the flexural mechanism was established to carry out the numerical simulation in order to testify the rationality of device design. Finally, the polishing experiment is carried out to prove the effectiveness of the vibration device. The experimental results show that this novel vibration assisted polishing device developed in this study can remove more effectively the cutting marks left by last process and obviously reduce the workpiece surface roughness.

  6. The Ventricular Assist Device in the Life of the Child: A Phenomenological Pediatric Study

    Science.gov (United States)

    van Manen, Michael A.

    2017-01-01

    What is it like for a child to live with an artificial heart? The use of some medical therapies in children requires developmental considerations, is associated with psychosocial consequences, and calls for ethical sensitivities. A critical case is the ventricular assist device (VAD), a mechanical pump used to support the functioning of a failing heart. As a pediatric therapy, the device can be used as a temporary solution for poor heart function, a bridge to transplantation or recovery, or as a destination therapy. While the mechanical-technical operation of the VAD is well understood, the clinical-technical aspects of young people living with this device are largely unexplored. Drawing on interviews of school-aged children, the aim of this phenomenological study is to explore how a VAD may structure or condition a child’s meaningful experience of their world outside the hospital. The driveline of an implanted VAD is the peripheral attachment, extruding through the skin to connect the controller-power supply. The materiality of the device may be interruptive, restrictive, and disturbing to the psycho-physical being and sense of self-identity of the child as a child. And while a child equipped with a VAD is not necessarily conspicuous among other children, the child may experience the device as an exposing presence, while living with the worry of a caregiver who takes on the role not simply of parent but of watchful health professional. A phenomenological understanding of the VAD should assist parents and caregiving health professionals knowing how to deal with specific issues arising in the life of the VAD child. PMID:28682718

  7. An exploratory study of sleep quality, daytime function, and quality of life in patients with mechanical circulatory support.

    Science.gov (United States)

    Casida, Jesus M; Brewer, Robert J; Smith, Cheryl; Davis, Jean E

    2012-07-01

    To identify and describe: (1) characteristics of sleep quality, daytime sleepiness, and quality of life (QOL) pre and post implantation of a left ventricular assist device (LVAD); (2) changes in sleep quality, daytime sleepiness, and QOL at baseline and 6 months post implant; and (3) relationships among the sleep quality, daytime sleepiness, and QOL variables. We employed an exploratory research design. Fifteen patients with continuous/non-pulsatile flow LVAD consented to partake in the study. However, only 12 patients completed the baseline and 6-month post-LVAD implant data. We used the Pittsburgh Sleep Quality Index (PSQI), Epworth Sleepiness Scale (ESS), and Minnesota Living with Heart Failure Questionnaire (MLHFQ) to measure study variables. Data were analyzed using IBM SPSS 19.0 software. Patients reported worse sleep quality accompanied by daytime sleepiness particularly at baseline, and persisting up to 6 months post LVAD implant. A significant improvement in QOL was observed at 6 months post implant, but remained at poor levels. Correlations among sleep disturbance and daytime dysfunction components of PSQI and global daytime sleepiness (ESS) with QOL were strong (Pearson's correlations r >.60; p values sleep quality, daytime sleepiness, and QOL in patients with LVADs. Our findings offer beginning evidence about the sleep-QOL connection in this population which warrants attention in clinical practice and research. Further research is required to clearly elucidate these phenomena in patients with mechanical circulatory support and other implantable artificial organs.

  8. Prototype of a mechanical assistance device for the wrists' flexion-extension movement

    International Nuclear Information System (INIS)

    Politti, Julio C; Puglisi, Lisandro J; Farfan, Fernando D

    2007-01-01

    Using CMU actuators, a Prototype of Mechanical Assistance Device for the Wrist's Flexion Movement (PMA) was developed and probed in a mechanical model, in order to be implemented in a future as a dynamic powered orthosis or as a rehabilitation assistant instrument. Two Mayor Actuators conformed by three CMU actuators arranged in a series configuration, allows to an artificial hand to be placed in four predefined positions: 0 0 , 20 0 , 40 0 and 60 0 . The synchronism and control of the actuators is achieved with the Programmable Control Module (PCM). It is capable to drive up to six CMU actuators, and possess two different modes of execution: a Manual mode and an Exercise mode. In the Manual Mode, the position of the hand responds directly to the commands of the keyboard of the front panel, and in the Exercise mode, the hand realizes a repetitive and programmed movement. The prototype was tested in 100 positions in the Manual Mode and for 225 works cycles in the Exercise Mode. The relative repetition error was less than 5% for both test. This prototype only consumes 4,15W, which makes it possible to be powered by small rechargeable batteries, allowing its use as a portable device

  9. Optimization of a miniature Maglev ventricular assist device for pediatric circulatory support.

    Science.gov (United States)

    Zhang, Juntao; Koert, Andrew; Gellman, Barry; Gempp, Thomas M; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J

    2007-01-01

    A miniature Maglev blood pump based on magnetically levitated bearingless technology is being developed and optimized for pediatric patients. We performed impeller optimization by characterizing the hemodynamic and hemocompatibility performances using a combined computational and experimental approach. Both three-dimensional flow features and hemolytic characteristics were analyzed using computational fluid dynamics (CFD) modeling. Hydraulic pump performances and hemolysis levels of three different impeller designs were quantified and compared numerically. Two pump prototypes were constructed from the two impeller designs and experimentally tested. Comparison of CFD predictions with experimental results showed good agreement. The optimized impeller remarkably increased overall pump hydraulic output by more than 50% over the initial design. The CFD simulation demonstrated a clean and streamlined flow field in the main flow path. The numerical results by hemolysis model indicated no significant high shear stress regions. Through the use of CFD analysis and bench-top testing, the small pediatric pump was optimized to achieve a low level of blood damage and improved hydraulic performance and efficiency. The Maglev pediatric blood pump is innovative due to its small size, very low priming volume, excellent hemodynamic and hematologic performance, and elimination of seal-related and bearing-related failures due to adoption of magnetically levitated bearingless motor technology, making it ideal for pediatric applications.

  10. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  11. Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro

    Directory of Open Access Journals (Sweden)

    Jia Ke

    2016-01-01

    Conclusions: This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety.

  12. The logistics and cost-effectiveness of circulatory support: advantages of the ABIOMED BVS 5000.

    Science.gov (United States)

    Couper, G S; Dekkers, R J; Adams, D H

    1999-08-01

    In 1994, the ABIOMED BVS 5000 was incorporated into our acute cardiac assist armamentarium. This report is a general overview of our experience. A hypothetical cost analysis focusing on specific devices and device-related personnel contrasted the BVS 5000 with our prior model of centrifugal pump use. In 3 years, 22 patients were supported with the BVS 5000, as a biventricular assist device in 40%, right ventricular assist device in 27%, and left ventricular assist device in 32%. Indications were postcardiotomy support in 12, acute myocarditis in 2, bridge to transplant in 4, and failed heart transplant in 4. The cost analysis was performed retrospectively. The actual cost of disposable blood pumps, including replacement pumps, and cannulae constituted the BVS cost. The hypothetical centrifugal costs included the disposables, replacement cones, as well as the labor costs of the continuous perfusionist coverage. Of the 22 patients, 10 (45%) were weaned and 13 (59%) were successfully discharged. Five patients were transplanted while on BVS 5000 support, accounting for a higher rate of discharge. Comparison of "actual" BVS costs with "projected" centrifugal costs revealed differences based upon the intended application of the BVS. In bridge-to-transplant patients with long duration of support, the daily cost of support was dramatically lower with the BVS 5000. For short-term postcardiotomy support, acute myocarditis, or failed transplant, the differences were small. Because the BVS 5000 was readily managed by the intensive care unit nursing staff, this system displaced centrifugal systems in our program. Outcome measures of weaning and successful discharge were improved relative to our prior experience with centrifugal pumps. Even without taking indirect costs into account, the hypothetical cost analysis supported continued use of the BVS system for acute cardiac assistance.

  13. Does reduced movement restrictions and use of assistive devices affect rehabilitation outcome after total hip replacement?

    DEFF Research Database (Denmark)

    Mikkelsen, Lone Ramer; Petersen, Annemette Krintel; Søballe, Kjeld

    2014-01-01

    slower recovery in patient-reported function after reduction in movement restrictions and use of assistive devices, but the difference was eliminated after 6 weeks. Reduced movement restrictions did not affect the other patient-reported outcomes and led to earlier return to work. CLINICAL REHABILITATION......). This group was compared to patients included the following 3 months with less restricted hip movement and use of assistive devices according to individual needs (unrestricted group). Questionnaires on function, pain, quality of life (HOOS), anxiety (HADS), working status and patient satisfaction were.......004). Return to work 6 weeks after THR for the unrestricted group compared to restricted group was: 53% versus 32% (P=0.045). No significant differences between groups in pain, symptoms, quality of life, anxiety/depression, hip dislocations and patient satisfaction. CONCLUSION: This study showed slightly...

  14. Novel circulatory connection from the acupoint Zhong Wan(CV12 to pancreas

    Directory of Open Access Journals (Sweden)

    Minsoo Kim

    2008-03-01

    Full Text Available Objectives : Demonstrating a novel circulatory path from the acupoint(CV12 to the pancreas. Method : Alcian blue(1% solution, 20μl, pH 7.4 was injected into the acupoint(CV12. Two hours later the surfaces of internal organs were observed by using a stereomicroscope. Results : Alcian blue arrived and colored the omental fat band(OFB on the pancreas. The OFB connected the head and tail of the pancreas, the pancreas and the spleen, and the pancreas and the stomach. Conclusion : The existence of a novel circulatory path from the acupoint CV12 to the pancreas and its OFB was demonstrated.

  15. Design of a Code-Maker Translator Assistive Input Device with a Contest Fuzzy Recognition Algorithm for the Severely Disabled

    Directory of Open Access Journals (Sweden)

    Chung-Min Wu

    2015-01-01

    Full Text Available This study developed an assistive system for the severe physical disabilities, named “code-maker translator assistive input device” which utilizes a contest fuzzy recognition algorithm and Morse codes encoding to provide the keyboard and mouse functions for users to access a standard personal computer, smartphone, and tablet PC. This assistive input device has seven features that are small size, easy installing, modular design, simple maintenance, functionality, very flexible input interface selection, and scalability of system functions, when this device combined with the computer applications software or APP programs. The users with severe physical disabilities can use this device to operate the various functions of computer, smartphone, and tablet PCs, such as sending e-mail, Internet browsing, playing games, and controlling home appliances. A patient with a brain artery malformation participated in this study. The analysis result showed that the subject could make himself familiar with operating of the long/short tone of Morse code in one month. In the future, we hope this system can help more people in need.

  16. An assistance device to help people with trunk impairment maintain posture.

    Science.gov (United States)

    Ogura, Tomoka; Itami, Taku; Yano, Ken'ichi; Mori, Ichidai; Kameda, Kazuhiro

    2017-07-01

    People with trunk impairment cannot lean forward because of the dysfunction of the trunk resulting from events such as cervical cord injury (CCI). It is therefore difficult for such people to work at a table because they may easily fall from their wheelchair, and it is also hard for them to return to their original position. This limits the activities of daily living (ADLs) of people with trunk impairment. These problems can be solved to some extent with equipment such as a wheelchair belt or a spinal orthosis that can help the person to maintain his or her posture. However, people cannot move freely with this equipment. Furthermore, if this equipment is used for a long time, there is a risk of physical pain and skin issues. In this study, we developed a device that assists the trunk of people with trunk impairment when they lean forward. This device supports people with trunk impairment so that they may take their meals at the table and prevents them from falling over their wheelchair without hindering their daily performance when they are sitting normally. The effectiveness of our proposed device was verified by experiments involving having a meal, operating a wheelchair, and colliding with a curb. Our device can help people with trunk impairment by improving their ADLs and quality of life (QOL).

  17. Use of Short-term Circulatory Support as a Bridge in Pediatric Heart Transplantation

    Directory of Open Access Journals (Sweden)

    Luiz Fernando Canêo

    2015-01-01

    Full Text Available Background: Heart transplantation is considered the gold standard therapy for the advanced heart failure, but donor shortage, especially in pediatric patients, is the main limitation for this procedure, so most sick patients die while waiting for the procedure. Objective: To evaluate the use of short-term circulatory support as a bridge to transplantation in end-stage cardiomyopathy. Methods: Retrospective clinical study. Between January 2011 and December 2013, 40 patients with cardiomyopathy were admitted in our Pediatric Intensive Care Unit, with a mean age of 4.5 years. Twenty patients evolved during hospitalization with clinical deterioration and were classified as Intermacs 1 and 2. One patient died within 24 hours and 19 could be stabilized and were listed. They were divided into 2 groups: A, clinical support alone and B, implantation of short-term circulatory support as bridge to transplantation additionally to clinical therapy. Results: We used short-term mechanical circulatory support as a bridge to transplantation in 9. In group A (n=10, eight died waiting and 2 patients (20% were transplanted, but none was discharged. In group B (n=9, 6 patients (66.7% were transplanted and three were discharged.The mean support time was 21,8 days (6 to 984h. The mean transplant waiting list time was 33,8 days. Renal failure and sepsis were the main complication and causeof death in group A while neurologic complications were more prevalent en group B. Conclusion: Mechanical circulatory support increases survival on the pediatric heart transplantation waiting list in patients classified as Intermacs 1 and 2.

  18. Diffractive optical devices produced by light-assisted trapping of nanoparticles.

    Science.gov (United States)

    Muñoz-Martínez, J F; Jubera, M; Matarrubia, J; García-Cabañes, A; Agulló-López, F; Carrascosa, M

    2016-01-15

    One- and two-dimensional diffractive optical devices have been fabricated by light-assisted trapping and patterning of nanoparticles. The method is based on the dielectrophoretic forces appearing in the vicinity of a photovoltaic crystal, such as Fe:LiNbO3, during or after illumination. By illumination with the appropriate light distribution, the nanoparticles are organized along patterns designed at will. One- and two-dimensional diffractive components have been achieved on X- and Z-cut Fe:LiNbO3 crystals, with their polar axes parallel and perpendicular to the crystal surface, respectively. Diffraction gratings with periods down to around a few micrometers have been produced using metal (Al, Ag) nanoparticles with radii in the range of 70-100 nm. Moreover, several 2D devices, such as Fresnel zone plates, have been also produced showing the potential of the method. The diffractive particle patterns remain stable when light is removed. A method to transfer the diffractive patterns to other nonphotovoltaic substrates, such as silica glass, has been also reported.

  19. Central extracorporeal membrane oxygenation requiring pulmonary arterial venting after near-drowning.

    Science.gov (United States)

    Kimura, Mitsutoshi; Kinoshita, Osamu; Fujimoto, Yoshifumi; Murakami, Arata; Shindo, Takahiro; Kashiwa, Koichi; Ono, Minoru

    2014-02-01

    Extracorporeal membrane oxygenation (ECMO) is an effective respiratory and circulatory support in patients in refractory cardiogenic shock or cardiac arrest. Peripheral ECMO sometimes requires left heart drainage; however, few reports state that pulmonary arterial (PA) venting is required during ECMO support. We present a case of a 14-year-old boy who required PA venting during ECMO support after resuscitation from near-drowning in freshwater. A biventricular assist device with an oxygenator implantation was intended on day 1; however, we were unable to proceed because of increasing of pulmonary vascular resistance from the acute lung injury. Central ECMO with PA venting was then performed. On day 13, central ECMO was converted to biventricular assist device with an oxygenator, which was removed on day 16. This case suggests that PA venting during ECMO support may be necessary in some cases of respiratory and circulatory failure with high pulmonary vascular resistance after near-drowning.

  20. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  1. Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients.

    Science.gov (United States)

    Cowger, Jennifer A; Naka, Yoshifumi; Aaronson, Keith D; Horstmanshof, Douglas; Gulati, Sanjeev; Rinde-Hoffman, Debbie; Pinney, Sean; Adatya, Sirtaz; Farrar, David J; Jorde, Ulrich P

    2018-01-01

    The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation. FC (New York Heart Association [NYHA] and 6-minute walk test [6MWT]) and HR-QOL (European Quality of Life [EQ-5D-5L] and the Kansas City Cardiomyopathy [KCCQ]) assessments were obtained at baseline and 6 months after HeartMate 3 (HM3, n = 151; Abbott, Abbott Park, IL) or HeartMate II (HMII, n = 138; Abbott) implant as part of the MOMENTUM 3 clinical trial. Metrics were compared between devices and in those with and without events. The proportion of patients "living well on an LVAS" at 6 months, defined as alive with satisfactory FC (NYHA I/II or 6MWT > 300 meters) and HR-QOL (overall KCCQ > 50), was evaluated. Although the median (25th-75th percentile) patient KCCQ (change for HM3: +28 [10-46]; HMII: +29 [9-48]) and EQ-5D-5L (change for HM3: -1 [-5 to 0]; HMII: -2 [-6 to 0]) scores improved from baseline to 6 months (p 0.05). Likewise, there was an equivalent improvement in 6MWT distance at 6 months in HM3 (+94 [1-274] meters] and HMII (+188[43-340 meters]) from baseline. In patients with SAEs (n = 188), 6MWTs increased from baseline (p < 0.001), but gains for both devices were less than those without SAE (HM3: +74 [-9 to 183] meters with SAE vs +140 [35-329] meters without SAE; HMII: +177 [47-356] meters with SAE vs +192 [23-337] meters without SAE, both p < 0.003). SAEs did not affect the 6-month HR-QOL scores. The "living well" end point was achieved in 145 HM3 (63%) and 120 HMII (68%) patients (p = 0.44). Gains in HR-QOL and FC were similar early after HM3

  2. An Examination of the Impact of an Assistive Technology Device on the Quality of Adult/Young Child Interactions

    Science.gov (United States)

    Plunkett, Diane M.

    2013-01-01

    The purpose of this study was to gain greater understanding of the potential benefits of assistive technology (AT) devices on young children's social development. Specifically, changes to the quality of the adult/young child social interactions as a function of the child's access to and use of his/her personal AT device was examined. Using a…

  3. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  4. Flow Visualization of Three-Dimensionality Inside the 12 cc Penn State Pulsatile Pediatric Ventricular Assist Device

    OpenAIRE

    Roszelle, Breigh N.; Deutsch, Steven; Manning, Keefe B.

    2010-01-01

    In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV...

  5. Development of a power-assisted lifting device for construction and periodic inspection

    International Nuclear Information System (INIS)

    Hayatsu, M.; Yamada, M.; Takasu, H.; Tagawa, Y.; Kajiwara, K.

    2001-01-01

    This study focuses on the control system design and control performance of a power-assisted lifting device. The device consists of several electric chain-blocks, each controlled by force sensors and a CPU. The mechanism is as follows: (1) Force sensors detect any chain tension changes (by human force), (2) The CPU calculates the required output, (3) Electric chain-blocks move the object in the intended direction. The feature of this device is that it does not require any information related to the suspension points of the electric chain-blocks. The controller was designed using the H method, which considers disturbances and aims to provide robust stability under the operation conditions of construction verified through experiments using a 700 kg steel dummy mass (control object) suspended by four electric chain-blocks. In the experiments, the controller, which was designed using the H method, was compared to the PI controller method, and the effectiveness of the H controller was proven. A control object could be moved, translated, and rotated by human force (of less than 10 kg). Positioning performance errors were suppressed to less than 0.5 mm, and operation time was reduced by about 50%. This device will improve working efficiency and rationalize lifting operations in nuclear power plants. (author)

  6. Development of a power-assisted lifting device for construction and periodic inspection

    Energy Technology Data Exchange (ETDEWEB)

    Hayatsu, M.; Yamada, M.; Takasu, H. [Hitachi Plant Engineering and Construction, Chiba-ken (Japan); Tagawa, Y. [Tokyo Univ. of Agriculture and Technology (Japan); Kajiwara, K. [National Research Institute for Earth Science and Disaster Prevention, Tokyo (Japan)

    2001-07-01

    This study focuses on the control system design and control performance of a power-assisted lifting device. The device consists of several electric chain-blocks, each controlled by force sensors and a CPU. The mechanism is as follows: (1) Force sensors detect any chain tension changes (by human force), (2) The CPU calculates the required output, (3) Electric chain-blocks move the object in the intended direction. The feature of this device is that it does not require any information related to the suspension points of the electric chain-blocks. The controller was designed using the H method, which considers disturbances and aims to provide robust stability under the operation conditions of construction verified through experiments using a 700 kg steel dummy mass (control object) suspended by four electric chain-blocks. In the experiments, the controller, which was designed using the H method, was compared to the PI controller method, and the effectiveness of the H controller was proven. A control object could be moved, translated, and rotated by human force (of less than 10 kg). Positioning performance errors were suppressed to less than 0.5 mm, and operation time was reduced by about 50%. This device will improve working efficiency and rationalize lifting operations in nuclear power plants. (author)

  7. Psychological distress in patients with a left ventricular assist device and their partners : An exploratory study

    NARCIS (Netherlands)

    Brouwers, C.J.; Denollet, J.; Caliskan, K.; de Jonge, N.; Constantinescu, A.; Young, Q.; Kaan, A.; Pedersen, S.S.

    2015-01-01

    Background: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure,and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. Methods: Anxiety,

  8. Psychological distress in patients with a left ventricular assist device and their partners : an exploratory study

    NARCIS (Netherlands)

    Brouwers, Corline; Denollet, Johan; Caliskan, Kadir; de Jonge, N; Constantinescu, Alina; Young, Quincy; Kaan, Annemarie; Pedersen, Susanne S

    BACKGROUND: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure, and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. METHODS: Anxiety,

  9. Left thoracotomy HeartWare implantation with outflow graft anastomosis to the descending aorta: a simplified bridge for patients with multiple previous sternotomies.

    Science.gov (United States)

    Umakanthan, Ramanan; Haglund, Nicholas A; Stulak, John M; Joyce, Lyle D; Ahmad, Rashid; Keebler, Mary E; Maltais, Simon

    2013-01-01

    Advances in mechanical circulatory support have been critical in bridging patients awaiting heart transplantation. In addition, improvement in device durability has enabled left ventricular assist device therapy to be applied as destination therapy in those not felt to be transplant candidate. Because of the increasing complexity of patients, there continues to be a need for alternative strategies for device implantation to bridge high-risk patients awaiting heart transplantation, wherein the risks of numerous previous sternotomies may be prohibitive. We present a unique technique for placement of the HeartWare ventricular assist device via left anterior thoracotomy to the descending aorta in a patient awaiting heart transplantation with a history of multiple previous sternotomies.

  10. Identification of tasks performed by stroke patients using a mobility assistive device

    DEFF Research Database (Denmark)

    Hester, Todd; Sherrill, Delsey M; Hamel, Mathieu

    2006-01-01

    of these devices. In this study, we propose the use of wearable sensors to identify tasks performed by stroke patients with a mobility assistive device. Subjects performed ten tasks with a three-axis accelerometer attached to their ankle and a neural network was trained to identify the task being performed...... tasks associated with the use of a cane. Therefore, we envision that the methodology presented in this paper could be used to evaluate the use of a cane in the context of the task being performed........ Results from 15 stroke patients indicated that these motor tasks can be reliably identified with a median sensitivity of 90 % at a median specificity of 95%. These results indicate that it is possible to use a single module with a three-axis accelerometer attached to the ankle to reliably identify motor...

  11. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  12. Memory-assisted measurement-device-independent quantum key distribution

    Science.gov (United States)

    Panayi, Christiana; Razavi, Mohsen; Ma, Xiongfeng; Lütkenhaus, Norbert

    2014-04-01

    A protocol with the potential of beating the existing distance records for conventional quantum key distribution (QKD) systems is proposed. It borrows ideas from quantum repeaters by using memories in the middle of the link, and that of measurement-device-independent QKD, which only requires optical source equipment at the user's end. For certain memories with short access times, our scheme allows a higher repetition rate than that of quantum repeaters with single-mode memories, thereby requiring lower coherence times. By accounting for various sources of nonideality, such as memory decoherence, dark counts, misalignment errors, and background noise, as well as timing issues with memories, we develop a mathematical framework within which we can compare QKD systems with and without memories. In particular, we show that with the state-of-the-art technology for quantum memories, it is potentially possible to devise memory-assisted QKD systems that, at certain distances of practical interest, outperform current QKD implementations.

  13. Memory-assisted measurement-device-independent quantum key distribution

    International Nuclear Information System (INIS)

    Panayi, Christiana; Razavi, Mohsen; Ma, Xiongfeng; Lütkenhaus, Norbert

    2014-01-01

    A protocol with the potential of beating the existing distance records for conventional quantum key distribution (QKD) systems is proposed. It borrows ideas from quantum repeaters by using memories in the middle of the link, and that of measurement-device-independent QKD, which only requires optical source equipment at the user's end. For certain memories with short access times, our scheme allows a higher repetition rate than that of quantum repeaters with single-mode memories, thereby requiring lower coherence times. By accounting for various sources of nonideality, such as memory decoherence, dark counts, misalignment errors, and background noise, as well as timing issues with memories, we develop a mathematical framework within which we can compare QKD systems with and without memories. In particular, we show that with the state-of-the-art technology for quantum memories, it is potentially possible to devise memory-assisted QKD systems that, at certain distances of practical interest, outperform current QKD implementations. (paper)

  14. CHF: circulatory homeostasis gone awry.

    Science.gov (United States)

    Weber, Karl T; Burlew, Brad S; Davis, Richard C; Newman, Kevin P; D'Cruz, Ivan A; Hawkins, Ralph G; Wall, Barry M; Parker, Robert B

    2002-01-01

    The role of the renin-angiotensin-aldosterone system (RAAS) is integral to salt and water retention, particularly by the kidneys. Over time, positive sodium balance leads first to intra- and then to extravascular volume expansion, with subsequent symptomatic heart failure. This report examines the role of the RAAS in regulating a less well recognized component essential to circulatory homeostasis--central blood volume. The regulation of central blood volume draws on integrative cardiorenal physiology and a key role played by the RAAS in its regulation. In presenting insights into the role of the RAAS in regulating central blood volume, this review also addresses other sodium-retaining states with a predisposition to edema formation, such as cirrhosis and nephrosis. (c)2002 CHF, Inc

  15. 21 CFR 884.6130 - Assisted reproduction microtools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction microtools. 884.6130 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6130 Assisted reproduction microtools. (a) Identification. Assisted reproduction microtools are pipettes or...

  16. 21 CFR 884.6200 - Assisted reproduction laser system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction laser system. 884.6200... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6200 Assisted reproduction laser system. (a) Identification. The assisted reproduction laser system is a device...

  17. Implantation of a HeartMate II left ventricular assist device via left thoracotomy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J

    2012-11-01

    Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Diseases of the circulatory system and the likelihood of their development in the workforce at the Chernobyl nuclear power plant

    International Nuclear Information System (INIS)

    Khomazyuk, N.N.; Goncharenko, L.I.; Kovalev, A.C.; Nastina, E.M.; Chebanyuk, C.V.

    1995-01-01

    Large doses of general or localized radiation can provoke changes in the circulatory system, can affect all layers of the heart and cause selective damage to vascular endothelium. A study of the condition of the circulatory system in the victims of the Chernobyl disaster was carried out by the authors in 1986. This paper presents the results of an investigation into the condition of the circulatory system of Chernobyl employees working for long periods with sources of ionizing radiation. (O.L.). 11 refs., 3 figs

  19. New Monitoring Technology to Objectively Assess Adherence to Prescribed Footwear and Assistive Devices During Ambulatory Activity

    NARCIS (Netherlands)

    Bus, Sicco A.; Waaijman, Roelof; Nollet, Frans

    2012-01-01

    Bus SA, Waaijman R, Nollet F. New monitoring technology to objectively assess adherence to prescribed footwear and assistive devices during ambulatory activity. Arch Phys Med Rehabil 2012;93:2075-9. Objective: To assess the validity and feasibility of a new temperature-based adherence monitor to

  20. Assistência circulatória com oxigenação por membrana extracorpórea (ECMO no adulto: um conceito falido ou esquecido? Adult extracorporeal life support: a failed or forgotten concept?

    Directory of Open Access Journals (Sweden)

    Alexandre Siciliano Colafranceschi

    2008-07-01

    oxygenation for temporary mechanical circulatory support of adults that present with acute refractory cardiogenic shock in our institution. There is no other published experience of the use of this system in this scenario in Brazil. OBJECTIVE: To describe our experience with the use of the extracorporeal membrane oxygenation for circulatory support in adults. METHODS: Retrospective analysis of the medical files of patients submitted to the implant of extracorporeal membrane oxygenation system for circulatory assistance in acute and refractory cardiogenic shock. RESULTS: Eleven patients (63,5yo; 45,5%male were considered for analysis from 2005 to 2007. Median support time was 77 hours (10-240h and 5 patients have survived 30 days (45,5%. Two patients were subsequently submitted to prolonged paracorporeal circulatory assistance. Mortality on ECMO (6 patients was due to multiple organ failure (66,6% and refractory bleeding (33,4%. CONCLUSION: ECMO system is an option to be used in acute refractory cardiogenic shock as a bridge to recovery or selecting patients that might benefit from prolonged paracorporeal assist devices (bridge to bridge.

  1. Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.

    Science.gov (United States)

    Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael

    2016-01-01

    In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Bridge to transplantation with a left ventricular assist device.

    Science.gov (United States)

    Jung, Jae Jun; Sung, Kiick; Jeong, Dong Seop; Kim, Wook Sung; Lee, Young Tak; Park, Pyo Won

    2012-04-01

    A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.

  3. Long-term Mechanical Circulatory Support System reliability recommendation by the National Clinical Trial Initiative subcommittee.

    Science.gov (United States)

    Lee, James

    2009-01-01

    The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.

  4. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.

  5. The biocompatibility of titanium cardiovascular devices seeded with autologous blood-derived endothelial progenitor cells: EPC-seeded antithrombotic Ti implants.

    Science.gov (United States)

    Achneck, Hardean E; Jamiolkowski, Ryan M; Jantzen, Alexandra E; Haseltine, Justin M; Lane, Whitney O; Huang, Jessica K; Galinat, Lauren J; Serpe, Michael J; Lin, Fu-Hsiung; Li, Madison; Parikh, Amar; Ma, Liqiao; Chen, Tao; Sileshi, Bantayehu; Milano, Carmelo A; Wallace, Charles S; Stabler, Thomas V; Allen, Jason D; Truskey, George A; Lawson, Jeffrey H

    2011-01-01

    Implantable and extracorporeal cardiovascular devices are commonly made from titanium (Ti) (e.g. Ti-coated Nitinol stents and mechanical circulatory assist devices). Endothelializing the blood-contacting Ti surfaces of these devices would provide them with an antithrombogenic coating that mimics the native lining of blood vessels and the heart. We evaluated the viability and adherence of peripheral blood-derived porcine endothelial progenitor cells (EPCs), seeded onto thin Ti layers on glass slides under static conditions and after exposure to fluid shear stresses. EPCs attached and grew to confluence on Ti in serum-free medium, without preadsorption of proteins. After attachment to Ti for 15 min, less than 5% of the cells detached at a shear stress of 100 dyne / cm(2). Confluent monolayers of EPCs on smooth Ti surfaces (Rq of 10 nm), exposed to 15 or 100 dyne/cm(2) for 48 h, aligned and elongated in the direction of flow and produced nitric oxide dependent on the level of shear stress. EPC-coated Ti surfaces had dramatically reduced platelet adhesion when compared to uncoated Ti surfaces. These results indicate that peripheral blood-derived EPCs adhere and function normally on Ti surfaces. Therefore EPCs may be used to seed cardiovascular devices prior to implantation to ameliorate platelet activation and thrombus formation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Contribution of Circulatory Disturbances in Subchondral Bone to the Pathophysiology of Osteoarthritis.

    Science.gov (United States)

    Aaron, Roy K; Racine, Jennifer; Dyke, Jonathan P

    2017-08-01

    This review describes the contributions of abnormal bone circulation to the pathophysiology of osteoarthritis. Combining dynamic imaging with MRI and PET with previous observations reveals that venous stasis and a venous outlet syndrome is most likely the key circulatory pathology associated with the initiation or progression of osteoarthritis. MRI and PET have revealed that venous outflow obstruction results in physicochemical changes in subchondral bone to which osteoblasts are responsive. The osteoblasts express an altered pattern of cytokines, many of which can serve as structural or signaling molecules contributing to both bone remodeling and cartilage degeneration. The patterns of circulatory changes are associated with alterations in the physicochemical environment of subchondral bone, including hypoxia. Osteoblast cytokines can transit the subchondral bone plate and calcified cartilage and communicate with chondrocytes.

  7. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    Science.gov (United States)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  8. Angiographic examinations of the circulatory development of living chick embryos

    International Nuclear Information System (INIS)

    Stoeter, P.; Buchhoecker, M.; Bruzek, W.; Drews, U.; Schulze, K.; Tuebingen Univ.; Tuebingen Univ.

    1980-01-01

    In chick embryos of an age of incubation of 5-14 days, the physiological development of the circulation and the morphological differentation of the arterical system were studied by intravital and postmortal angiography. For the examinations of the living embryos, a special radiographic and injection technique had to be developed. The contrast medium was injected into the umbilical veins and transported by the actions of the embryonic heart. Continuous ECG recordings showed no marked interference of the injections with the cardiac activity. According to the angiographic findings, the circulation is relatively fast within the main arteries, but the capillary perfusion is prolonged and lasts up to several minutes. The average circulatory velocity of the blood stream within the carotid artery increases parallel to the arterial enlargement, whereas the circulatory time decreases and the number of heart beats during the period of carotid opacification does not change to a great extent. By this, a steady transport of gas and nutritional material may be achieved in the growing arterial system. (orig.) [de

  9. Overview of Robotic Devices for Nursing Care Project.

    Science.gov (United States)

    Hirukawa, Hirohisa

    2017-01-01

    METI/AMED are conducting a project on the development and deployment of robotic devices for nursing care to enhance the autonomy of elderly persons and assist care givers. An evaluation protocol is presented and the devices developed in the project are introduced. The devices consist of transfer assist devices (wearable/non-wearable), walking assist devices (outdoor/indoor), safety surveillance sensors (nursing home/private home), bath lift and toilet assist.

  10. [Temperature that modifies the effect of air pollution on emergency room visits for circulatory and respiratory diseases in Beijing, China].

    Science.gov (United States)

    Wang, L L; Zhang, Q; Bai, R H; Mi, B B; Yan, H

    2017-08-10

    Objective: To analyze the temperature modification effect on emergency room visits for circulatory and respiratory diseases caused by air pollution, in Beijing. Methods: Data on both circulatory and respiratory diseases in 2010 and 2011 were collected, Both meteorological and air pollutants related data were obtained from the National Scientific Data Sharing Platform for Population and Health. By using the stratified time-series models, we analyzed the effects of air pollution on emergency room visits for circulatory and respiratory diseases under different temperature zones, from 2010 to 2011, in Beijing. Results: Low temperature (daily average temperatureeffect of air pollution index (API) on emergency room visits for circulatory diseases, Under 10 units of API, the relative risks and confidence interval appeared as 1.067 (1.054-1.080). However, high (daily average temperature between 24.4 ℃ and 28.5 ℃) and extra-high temperature (daily average temperature >28.5 ℃) could enhance the effect of API on emergency room visits for respiratory diseases, Under 10 units of API, the relative risks and confidence interval were 1.021 (1.015-1.028) and 1.006 (1.003-1.008), respectively. Conclusion: Temperature seemed to have modified the association between air pollution and both circulatory and respiratory diseases.

  11. An optimal controller for an electric ventricular-assist device: theory, implementation, and testing.

    Science.gov (United States)

    Klute, G K; Tasch, U; Geselowitz, D B

    1992-04-01

    This paper addresses the development and testing of an optimal position feedback controller for the Penn State electric ventricular-assist device (EVAD). The control law is designed to minimize the expected value of the EVAD's power consumption for a targeted patient population. The closed-loop control law is implemented on an Intel 8096 microprocessor and in vitro test runs show that this controller improves the EVAD's efficiency by 15-21%, when compared with the performance of the currently used feedforward control scheme.

  12. An accelerometry-based comparison of 2 robotic assistive devices for treadmill training of gait.

    Science.gov (United States)

    Regnaux, Jean-Philippe; Saremi, Kaveh; Marehbian, Jon; Bussel, Bernard; Dobkin, Bruce H

    2008-01-01

    Two commercial robotic devices, the Gait Trainer (GT) and the Lokomat (LOKO), assist task-oriented practice of walking. The gait patterns induced by these motor-driven devices have not been characterized and compared. A healthy participant chose the most comfortable gait pattern on each device and for treadmill (TM) walking at 1, 2 (maximum for the GT), and 3 km/h and over ground at similar speeds. A system of accelerometers on the thighs and feet allowed the calculation of spatiotemporal features and accelerations during the gait cycle. At the 1 and 2 km/h speed settings, single-limb stance times were prolonged on the devices compared with overground walking. Differences on the LOKO were decreased by adjusting the hip and knee angles and step length. At the 3 km/h setting, the LOKO approximated the participant's overground parameters. Irregular accelerations and decelerations from toe-off to heel contact were induced by the devices, especially at slower speeds. The LOKO and GT impose mechanical constraints that may alter leg accelerations-decelerations during stance and swing phases, as well as stance duration, especially at their slower speed settings, that are not found during TM and overground walking. The potential impact of these perturbations on training to improve gait needs further study.

  13. The Implications of the Shift Toward Donation After Circulatory Death in Australia

    Directory of Open Access Journals (Sweden)

    Janske Reiling, MD, PhD

    2017-12-01

    Discussion. This study shows that livers donated after circulatory death are an underused resource in Australia. Better use of these currently available organs would be a highly cost-effective way of reducing waiting list mortality in liver transplantation.

  14. Self-Organizing Wearable Device Platform for Assisting and Reminding Humans in Real Time

    Directory of Open Access Journals (Sweden)

    Yu Jin Park

    2016-01-01

    Full Text Available Most older persons would prefer “aging in my place,” that is, to remain in good health and live independently in their own home as long as possible. For assisting the independent living of older people, the ability to gather and analyze a user’s daily activity data would constitute a significant technical advance, enhancing their quality of life. However, the general approach based on centralized server has several problems such as the usage complexity, the high price of deployment and expansion, and the difficulty in identifying an individual person. To address these problems, we propose a wearable device platform for the life assistance of older persons that automatically records and analyzes their daily activity without intentional human intervention or a centralized server (i.e., cloud server. The proposed platform contains self-organizing protocols, Delay-Tolerant Messaging system, knowledge-based analysis and alerting for daily activities, and a hardware platform that provides low power consumption. We implemented a prototype smart watch, called Personal Activity Assisting and Reminding (PAAR, as a testbed for the proposed platform, and evaluated the power consumption and the service time of example scenarios.

  15. Reference Device-Assisted Adaptive Location Fingerprinting

    Directory of Open Access Journals (Sweden)

    Dongjin Wu

    2016-06-01

    Full Text Available Location fingerprinting suffers in dynamic environments and needs recalibration from time to time to maintain system performance. This paper proposes an adaptive approach for location fingerprinting. Based on real-time received signal strength indicator (RSSI samples measured by a group of reference devices, the approach applies a modified Universal Kriging (UK interpolant to estimate adaptive temporal and environmental radio maps. The modified UK can take the spatial distribution characteristics of RSSI into account. In addition, the issue of device heterogeneity caused by multiple reference devices is further addressed. To compensate the measuring differences of heterogeneous reference devices, differential RSSI metric is employed. Extensive experiments were conducted in an indoor field and the results demonstrate that the proposed approach not only adapts to dynamic environments and the situation of changing APs’ positions, but it is also robust toward measuring differences of heterogeneous reference devices.

  16. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  17. Association between percutaneous hemodynamic support device and survival from cardiac arrest in the state of Michigan.

    Science.gov (United States)

    Pressman, Andrew; Sawyer, Kelly N; Devlin, William; Swor, Robert

    2018-05-01

    The role of circulatory support in the post-cardiac arrest period remains controversial. Our objective was to investigate the association between treatment with a percutaneous hemodynamic support device and outcome after admission for cardiac arrest. We performed a retrospective study of adult patients with admission diagnosis of cardiac arrest or ventricular fibrillation (VF) from the Michigan Inpatient Database, treated between July 1, 2010, and June 30, 2013. Patient demographics, clinical characteristics, treatments, and disposition were electronically abstracted based on ICD-9 codes at the hospital level. Mixed-effects logistic regression models were fit to test the effect of percutaneous hemodynamic support device defined as either percutaneous left ventricular assist device (pLVAD) or intra-aortic balloon pump (IABP) on survival. These models controlled for age, sex, VF, myocardial infarction (MI), and cardiogenic shock with hospital modeled as a random effect. A total of 103 hospitals contributed 4393 patients for analysis, predominately male (58.8%) with a mean age of 64.1years (SD 15.5). On univariate analysis, younger age, male sex, VF as the initial rhythm, acute MI, percutaneous coronary intervention, percutaneous hemodynamic support device, and absence of cardiogenic shock were associated with survival to discharge (each p<0.001). Mixed-effects logistic regressions revealed use of percutaneous hemodynamic support device was significantly associated with survival among all patients (OR 1.8 (1.28-2.54)), and especially in those with acute MI (OR 1.95 (1.31-2.93)) or cardiogenic shock (OR 1.96 (1.29-2.98)). Treatment with percutaneous hemodynamic support device in the post-arrest period may provide left ventricular support and improve outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  19. Anchoring in Destination-Therapy Left Ventricular Assist Device Decision Making: A Mechanical Turk Survey.

    Science.gov (United States)

    Paine, Arcadia M; Allen, Larry A; Thompson, Jocelyn S; McIlvennan, Colleen K; Jenkins, Amy; Hammes, Andrew; Kroehl, Miranda; Matlock, Daniel D

    2016-11-01

    People with end-stage heart failure may have to decide about destination-therapy left ventricular assist device (DT-LVAD). Individuals facing difficult decisions often rely on heuristics, such as anchoring, which predictably bias decision outcomes. We aimed to investigate whether showing a larger historical Heartmate XVE creates an anchoring effect, making the smaller Heartmate II (HMII) appear more favorable. With the use of Amazon Mechanical Turk, participants watched videos asking them to imagine themselves dying of end-stage heart failure, then were presented the option of LVAD as potentially life-prolonging therapy. Participants were randomized to a control group who were only shown the HMII device, and the intervention group who saw the XVE device before the HMII. Participants then completed surveys. A total of 487 participants completed the survey (control = 252; intervention = 235); 79% were affect likelihood of accepting the LVAD, it did affect device perception. This article highlights an important point with clinical implications: factors such as anchoring have the potential to inappropriately influence perceptions and decisions and should be carefully considered in research and practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A first-in-man study of the Reitan catheter pump for circulatory support in patients undergoing high-risk percutaneous coronary intervention.

    Science.gov (United States)

    Smith, Elliot J; Reitan, Oyvind; Keeble, Thomas; Dixon, Kerry; Rothman, Martin T

    2009-06-01

    To investigate the safety of a novel percutaneous circulatory support device during high-risk percutaneous coronary intervention (PCI). The Reitan catheter pump (RCP) consists of a catheter-mounted pump-head with a foldable propeller and surrounding cage. Positioned in the descending aorta the pump creates a pressure gradient, reducing afterload and enhancing organ perfusion. Ten consecutive patients requiring circulatory support underwent PCI; mean age 71 +/- 9; LVEF 34% +/- 11%; jeopardy score 8 +/- 2.3. The RCP was inserted via the femoral artery. Hemostasis was achieved using Perclose sutures. PCI was performed via the radial artery. Outcomes included in-hospital death, MI, stroke, and vascular injury. Hemoglobin (Hb), free plasma Hb (fHb), platelets, and creatinine (cre) were measured pre PCI and post RCP removal. The pump was inserted and operated successfully in 9/10 cases (median 79 min). Propeller rotation at 10,444 +/- 1,424 rpm maintained an aortic gradient of 9.8 +/- 2 mm Hg. Although fHb increased, there was no significant hemolysis (4.7 +/- 2.4 mg/dl pre vs. 11.9 +/- 10.5 post, P = 0.04, reference 20 mg/dl). Platelets were unchanged (pre 257 +/- 74 x 10(9) vs. 245 +/- 63, P = NS). Renal function improved (cre pre 110 +/- 27 micromol/l vs. 99 +/- 28, P = 0.004). The RCP was not used in one patient following femoral introducer sheath related aortic dissection. All PCI procedures were successful with no deaths or strokes, one MI, and no vascular complications following pump removal. The RCP can be used safely in high-risk PCI patients. This device may be an alternative to other percutaneous systems when substantial cardiac support is needed. (c) 2009 Wiley-Liss, Inc.

  1. Exercise therapy for an older patient with left ventricular assist device.

    Science.gov (United States)

    Park, Won Hah; Seo, Yong Gon; Sung, Ji Dong

    2014-06-01

    A left ventricular assist device (LVAD) is a mechanical circulation support implanted for patients with end-stage heart failure. It may be used either as a bridge to cardiac transplantation or as a destination therapy. The health of a 75-year-old man with a medical history of systolic heart failure worsened. Therefore, he was recommended to have implanted a LVAD (Thoratec Corp.) as a destination therapy. After the surgery, he was enrolled in patient cardiac rehabilitation for the improvement of dyspnea and exercise capacity. In results, there is an improvement on his exercise capacity and quality of life. For the first time in Korea, we reported a benefit of exercise therapy after being implanted with a LVAD.

  2. [Cerebral oximetry in pulmonary thromboendarterectomy with circulatory arrest].

    Science.gov (United States)

    Catalán Escudero, P; González Román, A; Serra Ruiz, C N; Barbero Mielgo, M; García Fernández, J

    2014-02-01

    Pulmonary thromboendarterectomy is an uncommon procedure and should be performed with circulatory arrest. One of the major concerns is the postoperative central neurological injuries. Perioperative brain oxygen monitoring is advisable in this surgical procedure for the early detection of brain hypoperfusion episodes and their intensity as well as any other postoperative episodes that can deteriorate the neurological outcome. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  3. State-of-the-art implantable cardiac assist device therapy for heart failure: bridge to transplant and destination therapy.

    Science.gov (United States)

    Park, S J; Kushwaha, S S; McGregor, C G A

    2012-01-01

    Congestive heart failure is associated with poor quality of life (QoL) and low survival rates. The development of state-of-the-art cardiac devices holds promise for improved therapy in patients with heart failure. The field of implantable cardiac assist devices is changing rapidly with the emergence of continuous-flow pumps (CFPs). The important developments in this field, including pertinent clinical trials, registry reports, innovative research, and potential future directions are discussed in this paper.

  4. From Head to Toe: Respiratory, Circulatory, and Skeletal Systems. Book 3.

    Science.gov (United States)

    Wiebe, Arthur, Ed.; And Others

    Designed to supplement curricular programs dealing with the human body, this booklet offers an activity-based, student-oriented approach for middle school teachers and students. Twelve activities focus on principles and skills related to the respiratory, circulatory, and skeletal systems. Each activity consists of student sheets and a teacher's…

  5. Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report.

    Science.gov (United States)

    Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A

    2014-05-01

    Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.

  6. Rapid prototyping of 2D glass microfluidic devices based on femtosecond laser assisted selective etching process

    Science.gov (United States)

    Kim, Sung-Il; Kim, Jeongtae; Koo, Chiwan; Joung, Yeun-Ho; Choi, Jiyeon

    2018-02-01

    Microfluidics technology which deals with small liquid samples and reagents within micro-scale channels has been widely applied in various aspects of biological, chemical, and life-scientific research. For fabricating microfluidic devices, a silicon-based polymer, PDMS (Polydimethylsiloxane), is widely used in soft lithography, but it has several drawbacks for microfluidic applications. Glass has many advantages over PDMS due to its excellent optical, chemical, and mechanical properties. However, difficulties in fabrication of glass microfluidic devices that requires multiple skilled steps such as MEMS technology taking several hours to days, impedes broad application of glass based devices. Here, we demonstrate a rapid and optical prototyping of a glass microfluidic device by using femtosecond laser assisted selective etching (LASE) and femtosecond laser welding. A microfluidic droplet generator was fabricated as a demonstration of a microfluidic device using our proposed prototyping. The fabrication time of a single glass chip containing few centimeter long and complex-shaped microfluidic channels was drastically reduced in an hour with the proposed laser based rapid and simple glass micromachining and hermetic packaging technique.

  7. Selective cerebral perfusion prevents abnormalities in glutamate cycling and neuronal apoptosis in a model of infant deep hypothermic circulatory arrest and reperfusion.

    Science.gov (United States)

    Kajimoto, Masaki; Ledee, Dolena R; Olson, Aaron K; Isern, Nancy G; Robillard-Frayne, Isabelle; Des Rosiers, Christine; Portman, Michael A

    2016-11-01

    Deep hypothermic circulatory arrest is often required for the repair of complex congenital cardiac defects in infants. However, deep hypothermic circulatory arrest induces neuroapoptosis associated with later development of neurocognitive abnormalities. Selective cerebral perfusion theoretically provides superior neural protection possibly through modifications in cerebral substrate oxidation and closely integrated glutamate cycling. We tested the hypothesis that selective cerebral perfusion modulates glucose utilization, and ameliorates abnormalities in glutamate flux, which occur in association with neuroapoptosis during deep hypothermic circulatory arrest. Eighteen infant male Yorkshire piglets were assigned randomly to two groups of seven (deep hypothermic circulatory arrest or deep hypothermic circulatory arrest with selective cerebral perfusion for 60 minutes at 18℃) and four control pigs without cardiopulmonary bypass support. Carbon-13-labeled glucose as a metabolic tracer was infused, and gas chromatography-mass spectrometry and nuclear magnetic resonance were used for metabolic analysis in the frontal cortex. Following 2.5 h of cerebral reperfusion, we observed similar cerebral adenosine triphosphate levels, absolute levels of lactate and citric acid cycle intermediates, and carbon-13 enrichment among three groups. However, deep hypothermic circulatory arrest induced significant abnormalities in glutamate cycling resulting in reduced glutamate/glutamine and elevated γ-aminobutyric acid/glutamate along with neuroapoptosis, which were all prevented by selective cerebral perfusion. The data suggest that selective cerebral perfusion prevents these modifications in glutamate/glutamine/γ-aminobutyric acid cycling and protects the cerebral cortex from apoptosis. © The Author(s) 2016.

  8. A durability study of a paracorporeal pulsatile electro-mechanical pneumatic biventricular assist device.

    Science.gov (United States)

    Choi, Hyuk; Lee, Heung-Man; Nam, Kyoung Won; Choi, Jaesoon; Lee, Jung-Joo; Kim, Ho Chul; Song, Seung Joon; Ahn, Chi Bum; Son, Ho Sung; Lim, Choon Hak; Son, Kuk Hui; Park, Yong Doo; Jeong, Gi Seok; Sun, Kyung

    2011-06-01

    In 2002, the paracorporeal pulsatile electro-mechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm). © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Cross-cultural adaptation of the psychosocial impact of assistive device scale (PIADS) for Puerto Rican assistive technology users.

    Science.gov (United States)

    Orellano, Elsa M; Jutai, Jeffrey W

    2013-01-01

    Assistive technology (AT) is important for individuals with disabilities' independence and participation in daily life, and there is a lack of valid AT outcome tools for the Puerto Rican population. This pilot study examined the content validity of a new adaptation of the Psychosocial Impact of Assistive Device Scale (PIADS): the Puerto Rican-Spanish PIADS (PR-PIADS). Following standard procedures, the cultural adaptation methodology included a bilingual multidisciplinary committee review of the original (English language) and Spanish versions of the PIADS and pilot testing of the preliminary version of the PR-PIADS with 20 AT users. The committee recommended a total of 58 semantic and conceptual modifications of the Spanish PIADS. Pilot data analysis resulted in 4 additional semantic and conceptual modifications of items that did not reach the minimum content validity ratio of 0.42 for a panel composed by 20 members: competence (0), efficiency (-0.6), performance (-0.95), and eagerness to take chances (-0.6). This pilot study demonstrated evidence of initial content validity of the PR-PIADS. Future research is required before using this tool with greater confidence to address the construct validity and reliability that are also critical to a successful cultural adaptation.

  10. Theological reflections on donation after circulatory death: the wisdom of Paul Ramsey and Moshe Feinstein.

    Science.gov (United States)

    Jotkowitz, A

    2008-10-01

    Due to the worldwide shortage of organs for transplantation, there has been an increased use of organs obtained after circulatory death alone. A protocol for this procedure has recently been approved by a major transplant consortium. This development raises serious moral and ethical concerns. Two renowned theologians of the previous generation, Paul Ramsey and Moshe Feinstein, wrote extensively on the ethical issues relating to transplantation, and their work has much relevance to current moral dilemmas. Their writings relating to definition of death, organ transplantation and the care of the terminally ill are briefly presented, and their potential application to the moral problem of organ donation after circulatory death is discussed.

  11. Left ventricular assist device implantation in a patient who had previously undergone apical myectomy for hypertrophic cardiomyopathy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Topilsky, Yan; Grogan, Martha A; Park, Soon J

    2012-03-01

    Apical hypertrophy is a rare variant of hypertropic cardiomyopathy. These patients may present with end-stage congestive heart failure subsequent to long standing diastolic dysfunction. We report the technique for left ventricular assist device insertion in a patient with previous apical myectomy for hypertrophic cardiomyopathy. © 2012 Wiley Periodicals, Inc.

  12. Validation of a laser-assisted wound measurement device in a wound healing model.

    Science.gov (United States)

    Constantine, Ryan S; Bills, Jessica D; Lavery, Lawrence A; Davis, Kathryn E

    2016-10-01

    In the treatment and monitoring of a diabetic or chronic wound, accurate and repeatable measurement of the wound provides indispensable data for the patient's medical record. This study aims to measure the accuracy of the laser-assisted wound measurement (LAWM) device against traditional methods in the measurement of area, depth and volume. We measured four 'healing' wounds in a Play-Doh(®) -based model over five subsequent states of wound healing progression in which the model was irregularly filled in to replicate the healing process. We evaluated the LAWM device against traditional methods including digital photograph assessment with National Institutes of Health ImageJ software, measurements of depth with a ruler and weight-to-volume assessment with dental paste. Statistical analyses included analysis of variance (ANOVA) and paired t-tests. We demonstrate that there are significantly different and nearly statistically significant differences between traditional ruler depth measurement and LAWM device measurement, but there are no statistically significant differences in area measurement. Volume measurements were found to be significantly different in two of the wounds. Rate of percentage change was analysed for volume and depth in the wound healing model, and the LAWM device was not significantly different than the traditional measurement technique. While occasionally inaccurate in its absolute measurement, the LAWM device is a useful tool in the clinician's arsenal as it reliably measures rate of percentage change in depth and volume and offers a potentially aseptic alternative to traditional measurement techniques. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  13. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  14. Circulatory Arrest: A Surgical Option for Adult Window Ductus Closure

    Directory of Open Access Journals (Sweden)

    Vithalkumar Malleshi Betigeri

    2012-03-01

    Full Text Available The window ductus , an atypical type of patent ductus arteriosus(PDA is a characteristically large in size(>2cm with no recognizable length, characteristic continuation of main pulmonary artery with aortic arch and absence of internal ductal tissue. Surgical safety and effectiveness of its closure can be increased by using cardiopulmonary bypass (CPB and hypothermic total circulatory arrest (HTCA via median sternotomy.

  15. Pathophysiology of cerebral circulatory disorders in idiopathic normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Takeuchi, Totaro; Goto, Hiromi; Izaki, Kenji

    2007-01-01

    This study was conducted to elucidate the pathologic conditions of cerebral circulatory disorders in idiopathic normal pressure hydrocephalus (iNPH). Among 44 possible iNPH patients, 40 patients underwent shunt surgery based on diagnostic flow charts plotted by the Southern Tohoku method and were evaluated to be shunt-effective at the end of the first post-surgical month. The cerebral blood flow (CBF) was measured by N-isopropyl-( 123 I)-P-iodo-amphetamine single photon emission computed tomography (mean, mCBF; cortical region, cCBF; thalamus-basal ganglia region, tbCBF on autoradiography [ARG] method) and the perfusion patterns of the cerebral cortex were measured based on three-dimensional stereotactic surface projection (3D-SSP) Z-score images, before and 1 month after the surgery in all 40 subjects. The mCBF rose significantly from 32.1±2.74 ml/100 g/min before surgery to 39.8±3.02 ml/100 g/min after surgery (p<0.03). Investigation of the change of CBF revealed reductions in the cCBF (3 cases), tbCBF (9 cases), and cCBF+tbCBF (28 cases), with the reduced-cCBF group totaling 31 cases and the reduced-tbCBF group totaling 37 cases. Investigation of cerebral cortex hypoperfusion by 3D-SSP Z-score revealed 31 cases with hypoperfusion (frontal lobe type [19 cases], occipitotemporal lobe type [5 cases], mixed type [7 cases]) and nine cases with cortical normoperfusion (N). The pattern of reduction of the cortical blood flow on ARG method was favorably correlated with the pattern of hypoperfusion of the cerebral cortex on 3D-SSP Z-score images before surgery. A reduction of blood flow was found in the thalamus-basal ganglia region of all N type cases. The blood flow improved in 19 of 31 (61.3%) cases of the reduced-cCBF group and in 32 of 37 (86.5%) cases of the reduced-tbCBF group. All of the cases without detectable improvement exhibited increased blood flow in non-reduction areas. Investigation of the hypoperfusion patterns of the cerebral cortex on 3D-SSP Z

  16. Pulmonary circulatory effects of norepinephrine in newborn infants with persistent pulmonary hypertension.

    Science.gov (United States)

    Tourneux, Pierre; Rakza, Thameur; Bouissou, Antoine; Krim, Gérard; Storme, Laurent

    2008-09-01

    To evaluate the respiratory and the pulmonary circulatory effects of norepinephrine in newborn infants with persistent pulmonary hypertension (PPHN)-induced cardiac dysfunction. Inclusion criteria were: 1) Newborn infants >35 weeks gestational age; 2) PPHN treated with inhaled nitric oxide; and 3) symptoms of circulatory failure despite adequate fluid resuscitation. Lung function and pulmonary hemodynamic variables assessed with Doppler echocardiography were recorded prospectively before and after starting norepinephrine. Eighteen newborns were included (gestational age: 37 +/- 3 weeks; birth weight: 2800 +/- 700 g). After starting norepinephrine, systemic pressure and left ventricular output increased respectively from 33 +/- 4 mm Hg to 49 +/- 4 mm Hg and from 172 +/- 79 mL/kg/min to 209+/-90 mL/kg/min (P ventilatory variables have not been changed, the post-ductal transcutaneous arterial oxygen saturation increased from 89% +/- 1% to 95% +/- 4%, whereas the oxygen need decreased from 51% +/- 24% to 41% +/- 20% (P newborn infants with PPHN through a decrease in pulmonary/systemic artery pressure ratio and improved cardiac performance.

  17. Heart Transplant and Mechanical Circulatory Support in Patients With Advanced Heart Failure.

    Science.gov (United States)

    Sánchez-Enrique, Cristina; Jorde, Ulrich P; González-Costello, José

    2017-05-01

    Patients with advanced heart failure have a poor prognosis and heart transplant is still the best treatment option. However, the scarcity of donors, long waiting times, and an increasing number of unstable patients have favored the development of mechanical circulatory support. This review summarizes the indications for heart transplant, candidate evaluation, current immunosuppression strategies, the evaluation and treatment of rejection, infectious prophylaxis, and short and long-term outcomes. Regarding mechanical circulatory support, we distinguish between short- and long-term support and the distinct strategies that can be used: bridge to decision, recovery, candidacy, transplant, and destination therapy. We then discuss indications, risk assessment, management of complications, especially with long-term support, and outcomes. Finally, we discuss future challenges and how the widespread use of long-term support for patients with advanced heart failure will only be viable if their complications and costs are reduced. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Experience With a Long-term Pulsatile Ventricular Assist Device as a Bridge to Heart Transplant in Adults.

    Science.gov (United States)

    Gómez Bueno, Manuel; Segovia Cubero, Javier; Serrano Fiz, Santiago; Ugarte Basterrechea, Juan; Hernández Pérez, Francisco José; Goirigolzarri Artaza, Josebe; Castedo Mejuto, Evaristo; Burgos Lázaro, Raúl; García Montero, Carlos; Moñivas Palomero, Vanessa; Mingo Santos, Susana; González Román, Ana Isabel; Álvarez Avelló, José Manuel; Vidal Fernández, Mercedes; Forteza Gil, Alberto; Alonso-Pulpón, Luis

    2017-09-01

    Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Outcomes of patients with right ventricular failure on milrinone after left ventricular assist device implantation.

    Science.gov (United States)

    Tsiouris, Athanasios; Paone, Gaetano; Brewer, Robert J; Nemeh, Hassan W; Borgi, Jamil; Morgan, Jeffrey A

    2015-01-01

    Previous studies have grouped together both patients requiring right ventricular assist devices (RVADs) with patients requiring prolonged milrinone therapy after left ventricular assist device (LVAD) implantation. We retrospectively identified 149 patients receiving LVADs and 18 (12.1%) of which developed right ventricular (RV) failure. We then separated these patients into those requiring RVADs versus prolonged milrinone therapy. This included 10 patients who were treated with prolonged milrinone and eight patients who underwent RVAD placement. Overall, the RV failure group had worse survival compared with the non-RV failure cohort (p = 0.038). However, this was only for the subgroup of patients who required RVADs, who had a 1, 6, 12, and 24 month survival of 62.5%, 37.5%, 37.5%, and 37.5%, respectively, versus 96.8%, 92.1%, 86.7%, and 84.4% for patients without RV failure (p milrinone therapy for RV failure had similar survivals compared with patients without RV failure. In the RV failure group, age, preoperative renal failure, and previous cardiac surgery were predictors of the need for prolonged postoperative milrinone. As LVADs become a more widely used therapy for patients with refractory, end-stage heart failure, it will be important to reduce the incidence of RV failure, as it yields significant morbidity and increases cost.

  20. Tooling device design for vibration-assisted high speed shaping of PMMA

    International Nuclear Information System (INIS)

    Mostofa, Md. Golam; Noh, J. H.; Kim, H. Y.; Ahn, J. H.; Kang, D. B.

    2010-01-01

    PMMA optical components that are used as one of the most important parts of high precision equipment and machines are increasingly replacing the glass due to the various advantages of PMMA. Especially in Light Guide Panels, the PMMA sheet that is used in Liquid Crystal Displays plays an important role in scattering the incident light and requires very fine machining as the sheet is directly related to the optical characteristics of the panels. The High Speed End milling and High Speed Shaping processes that are widely adopted and applied to the precise machining of Light Incident Plane still have quality problems, such as cracks, breakages, poor waviness, and straightness. This paper presents the tooling device design for machining a Light Incident Plane through vibration-assisted High Speed Shaping for increasing the optical quality by minimizing the above-mentioned problems. The cutting tool and the tool post presented in this paper are designed by the authors to increase the magnitude of the cutting stroke by adopting the resonant frequency without weakening the stiffness and to reduce vibrations during even high speed feeding. The dynamic characteristics of the cutting tool and the tool post are evaluated through simulation and experiment as well. The results reveal very appropriate dynamic characteristics for vibration-assisted High Speed Shaping

  1. Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.

    Science.gov (United States)

    Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J

    2014-03-01

    Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand

  2. Nitroglycerin reverts clinical manifestations of poor peripheral perfusion in patients with circulatory shock

    NARCIS (Netherlands)

    A.A.P. Lima (Alexandre ); M.E. van Genderen (Michel); J. van Bommel (Jasper); E. Klijn (Elko); T. Jansem (Tim); J. Bakker (Jan)

    2014-01-01

    textabstractIntroduction: Recent clinical studies have shown a relationship between abnormalities in peripheral perfusion and unfavorable outcome in patients with circulatory shock. Nitroglycerin is effective in restoring alterations in microcirculatory blood flow. The aim of this study was to

  3. Intraoperative Transesophageal Echocardiography and Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K

    2018-02-15

    To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. 21 CFR 884.6150 - Assisted reproduction micromanipulators and microinjectors.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction micromanipulators and... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6150 Assisted reproduction micromanipulators and microinjectors. (a) Identification...

  5. 21 CFR 884.6140 - Assisted reproduction micropipette fabrication instruments.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction micropipette fabrication... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6140 Assisted reproduction micropipette fabrication instruments. (a) Identification...

  6. Electric poling-assisted additive manufacturing process for PVDF polymer-based piezoelectric device applications

    International Nuclear Information System (INIS)

    Lee, ChaBum; Tarbutton, Joshua A

    2014-01-01

    This paper presents a new additive manufacturing (AM) process to directly and continuously print piezoelectric devices from polyvinylidene fluoride (PVDF) polymeric filament rods under a strong electric field. This process, called ‘electric poling-assisted additive manufacturing or EPAM, combines AM and electric poling processes and is able to fabricate free-form shape piezoelectric devices continuously. In this process, the PVDF polymer dipoles remain well-aligned and uniform over a large area in a single design, production and fabrication step. During EPAM process, molten PVDF polymer is simultaneously mechanically stresses in-situ by the leading nozzle and electrically poled by applying high electric field under high temperature. The EPAM system was constructed to directly print piezoelectric structures from PVDF polymeric filament while applying high electric field between nozzle tip and printing bed in AM machine. Piezoelectric devices were successfully fabricated using the EPAM process. The crystalline phase transitions that occurred from the process were identified by using the Fourier transform infrared spectroscope. The results indicate that devices printed under a strong electric field become piezoelectric during the EPAM process and that stronger electric fields result in greater piezoelectricity as marked by the electrical response and the formation of sharper peaks at the polar β crystalline wavenumber of the PVDF polymer. Performing this process in the absence of an electric field does not result in dipole alignment of PVDF polymer. The EPAM process is expected to lead to the widespread use of AM to fabricate a variety of piezoelectric PVDF polymer-based devices for sensing, actuation and energy harvesting applications with simple, low cost, single processing and fabrication step. (paper)

  7. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    Science.gov (United States)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  8. An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.

    Science.gov (United States)

    Tozzi, Piergiorgio; Maertens, Audrey; Emery, Jonathan; Joseph, Samuel; Kirsch, Matthias; Avellan, François

    2017-11-24

    We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population. The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured. At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%. The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.

  9. Single-center experience of the bridge-to-bridge strategy using the Nipro paracorporeal ventricular assist device.

    Science.gov (United States)

    Yoshitake, Shuichi; Kinoshita, Osamu; Nawata, Kan; Hoshino, Yasuhiro; Itoda, Yoshifumi; Kimura, Mitsutoshi; Yamauchi, Haruo; Ono, Minoru

    2018-06-25

    Currently, we use the Nipro paracorporeal VAD (p-VAD) for initial short-term ventricular support, as a bridge to decision (BTD) or a bridge to candidacy (BTC) treatment, in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) levels 1 and 2 patients. However, it is possible that compared to patients with primary implantable-VADs (P-iVAD), the bridge-to-bridge (BTB) patients are more likely to develop complications. This retrospective study used data from 24 consecutive BTB patients who were initially implanted with Nipro p-VAD as BTD or BTC treatments between April 2011 and March 2016, and subsequently underwent conversion to an i-VAD. The data from 72 patients who underwent a primary i-VAD (P-iVAD) procedure were used for comparison. Between the two groups, there was no significant difference in the incidence of infectious events (p = 0.72) or stroke (p = 0.44). Orthotropic heart transplantation was performed in 6 of the 24 patients in the BTB group and in 21 of the 72 patients in the P-iVAD group. The 1- and 2-year survival rates were 95.8% and 95.8% in the BTB group and 91% and 85.8% in the P-iVAD group; these values were not significantly different between groups (p = 0.91). Based on these results we conclude that BTB using Nipro p-VAD is a reasonable strategy for treating patients with severe decompensated end-stage heart failure.

  10. Diseases of the circulatory system: health status and perspectives for changes

    Directory of Open Access Journals (Sweden)

    V. I. Klimenko

    2014-02-01

    Full Text Available During last 20 years rates of incidence and prevalence of diseases of the circulatory system in Ukraine have been growing from year to year and became problems of current interest. According to the program of WHO, realization of diseases prevention is provided by using of scientific justification and monitoring of health indexes, including diseases of the circulatory system. Goal of our research was to analyze health status of population of Zaporozhye region concerning cardiovascular diseases. Data since 1995 to 2012 y. were taken in the Center of medical statistics of Zaporozhye region. Comparative analysis of obtained data was conducted in dynamics and with definition of specific weight of able to work population in structure of indexes and gender differences. In article we showed, that on the background of depopulation of Ukraine during last 20 years, prevalence of diseases of the circulatory system increased by 2 times, and level of mortality from them increased for 45%. Specific weight of mortality from diseases of the circulatory system among adult population (state for 01.2013 y. in Ukraine was 65,7%, in Zaporozhye region – 63,6%, among able to work population – 30,5%, in Zaporozhye region – 33,4%, but mortality among able to work men in Zaporozhye region was in 5,5 times higher than in women. Specific weight of the diseases of the circulatory system in structure of general morbidity in total population in Ukraine was 31,5%, among able to work population – 24,1%; among total population of Zaporozhye region – 36,6% (in town – 35,0%; in country region – 39,8%, among able to work population of Zaporozhye region – 24,6% (in town – 22,8%; in country region – 27,6%. Structure of general morbidity of the cardiovascular diseases during last 10 years in Ukraine and in Zaporozhye region is stable. Leading place belongs to arterial hypertension: 56,1%- in Ukraine, 57,7 % - in Zaporozhye region. Comparing to Ukraine, before 2005 y

  11. Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device.

    Science.gov (United States)

    Burgreen, Greg W; Loree, Howard M; Bourque, Kevin; Dague, Charles; Poirier, Victor L; Farrar, David; Hampton, Edward; Wu, Z Jon; Gempp, Thomas M; Schöb, Reto

    2004-10-01

    The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of physiological operating conditions. The HeartMate III is a centrifugal flow pump with a magnetically suspended rotor. The complete pump was analyzed using computational fluid dynamics (CFD) analysis and experimental particle imaging flow visualization (PIFV). A comparison of CFD predictions to experimental imaging shows good agreement. Both CFD and experimental PIFV confirmed well-behaved flow fields in the main components of the HeartMate III pump: inlet, volute, and outlet. The HeartMate III is shown to exhibit clean flow features and good surface washing across its entire operating range.

  12. A 20-year multicentre outcome analysis of salvage mechanical circulatory support for refractory cardiogenic shock after cardiac surgery

    Directory of Open Access Journals (Sweden)

    Maziar Khorsandi

    2016-11-01

    Full Text Available Abstract Background Refractory post-cardiotomy cardiogenic shock (PCCS is a relatively rare phenomenon that can lead to rapid multi-organ dysfunction syndrome and is almost invariably fatal without advanced mechanical circulatory support (AMCS, namely extra-corporeal membrane oxygenation (ECMO or ventricular assist devices (VAD. In this multicentre observational study we retrospectively analyzed the outcomes of salvage venoarterial ECMO (VA ECMO and VAD for refractory PCCS in the 3 adult cardiothoracic surgery centres in Scotland over a 20-year period. Methods The data was obtained through the Edinburgh, Glasgow and Aberdeen cardiac surgery databases. Our inclusion criteria included any adult patient from April 1995 to April 2015 who had received salvage VA ECMO or VAD for PCCS refractory to intra-aortic balloon pump (IABP and maximal inotropic support following adult cardiac surgery. Results A total of 27 patients met the inclusion criteria. Age range was 34–83 years (median 51 years. There was a large male predominance (n = 23, 85 %. Overall 23 patients (85 % received VA ECMO of which 14 (61 % had central ECMO and 9 (39 % had peripheral ECMO. Four patients (15 % were treated with short-term VAD (BiVAD = 1, RVAD = 1 and LVAD = 2. The most common procedure-related complication was major haemorrhage (n = 10. Renal failure requiring renal replacement therapy (n = 7, fatal stroke (n = 5, septic shock (n = 2, and a pseudo-aneurysm at the femoral artery cannulation site (n = 1 were also observed. Overall survival to hospital discharge was 40.7 %. All survivors were NYHA class I-II at 12 months’ follow-up. Conclusion AMCS for refractory PCCS carries a survival benefit and achieves acceptable functional recovery despite a significant complication rate.

  13. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  14. Ergonomic evaluation of a wearable assistive device for overhead work.

    Science.gov (United States)

    Rashedi, Ehsan; Kim, Sunwook; Nussbaum, Maury A; Agnew, Michael J

    2014-01-01

    Overhead work is an important risk factor for upper extremity (UE) musculoskeletal disorders. We examined the potential of a mechanical arm and an exoskeletal vest as a wearable assistive device (WADE) for overhead work. Twelve participants completed 10 minutes of simulated, intermittent overhead work, using each of three payloads (1.1, 3.4 and 8.1 kg) and with/without the WADE. Ratings of perceived discomfort (RPDs) and electromyography (EMG) were obtained for the upper arms, shoulders and low back. Using the WADE, UE RPDs decreased by ∼50% with the heavier payloads, whereas smaller (∼25%) and non-significant increases in low-back RPDs were found and were relatively independent of payload. Changes in RPDs with WADE use were consistent with physical demands indicated by EMG, though EMG-based differences in fatigue were less apparent. Participants generally preferred using the WADE, particularly with heavier payloads. These results supported the potential utility of a WADE as an intervention for overhead work.

  15. Environmental barriers to participation and facilitators for use of three types of assistive technology devices.

    Science.gov (United States)

    Widehammar, Cathrine; Lidström, Helene; Hermansson, Liselotte

    2017-08-07

    The aim was to compare the presence of environmental barriers to participation and facilitators for assistive technology (AT) use and study the relation between barriers and AT use in three different AT devices. A cross-sectional survey was conducted. Inclusion criteria were ≥one year of experience as a user of myoelectric prosthesis (MEP), powered mobility device (PMD), or assistive technology for cognition (ATC) and age 20-90 years. Overall, 156 participants answered the Swedish version of the Craig Hospital Inventory of Environmental Factors and a study-specific questionnaire on facilitating factors. Non-parametric tests were used for comparisons. Barriers to participation were lowest in MEP users (md=0.12; p>0.001), and highest in ATC users (md=1.56; p>0.001) with the least support for AT use (p>0.001 - p=0.048). A positive correlation between fewer barriers and higher use of MEP was seen (r=0.30, p=0.038). The greatest barriers to participation were Natural environment, Surroundings and Information, and the most support came from relatives and professionals. Support, training and education are vital in the use of AT. These factors may lead to a more sustained and prolonged use of AT and may enable increased participation. Future research should focus on interventions that meet the needs of people with cognitive disabilities.

  16. Generalized derivation of the added-mass and circulatory forces for viscous flows

    Science.gov (United States)

    Limacher, Eric; Morton, Chris; Wood, David

    2018-01-01

    The concept of added mass arises from potential flow analysis and is associated with the acceleration of a body in an inviscid irrotational fluid. When shed vorticity is modeled as vortex singularities embedded in this irrotational flow, the associated force can be superimposed onto the added-mass force due to the linearity of the governing Laplace equation. This decomposition of force into added-mass and circulatory components remains common in modern aerodynamic models, but its applicability to viscous separated flows remains unclear. The present work addresses this knowledge gap by presenting a generalized derivation of the added-mass and circulatory force decomposition which is valid for a body of arbitrary shape in an unbounded, incompressible fluid domain, in both two and three dimensions, undergoing arbitrary motions amid continuous distributions of vorticity. From the general expression, the classical added-mass force is rederived for well-known canonical cases and is seen to be additive to the circulatory force for any flow. The formulation is shown to be equivalent to existing theoretical work under the specific conditions and assumptions of previous studies. It is also validated using a numerical simulation of a pitching plate in a steady freestream flow, conducted by Wang and Eldredge [Theor. Comput. Fluid Dyn. 27, 577 (2013), 10.1007/s00162-012-0279-5]. In response to persistent confusion in the literature, a discussion of the most appropriate physical interpretation of added mass is included, informed by inspection of the derived equations. The added-mass force is seen to account for the dynamic effect of near-body vorticity and is not (as is commonly claimed) associated with the acceleration of near-body fluid which "must" somehow move with the body. Various other consequences of the derivation are discussed, including a concept which has been labeled the conservation of image-vorticity impulse.

  17. Delayed Referral Results in Missed Opportunities for Organ Donation After Circulatory Death.

    Science.gov (United States)

    Krmpotic, Kristina; Payne, Clare; Isenor, Cynthia; Dhanani, Sonny

    2017-06-01

    Rates of organ donation and transplantation have steadily increased in the United States and Canada over the past decade, largely attributable to a notable increase in donation after circulatory death. However, the number of patients awaiting solid organ transplantation continues to remain much higher than the number of organs transplanted each year. The objective of this study was to determine the potential to increase donation rates further by identifying gaps in the well-established donation after circulatory death process in Ontario. Retrospective cohort study. Provincial organ procurement organization. Patients who died in designated donation hospitals within the province of Ontario, Canada between April 1, 2013, and March 31, 2015. None. Of 1,407 patient deaths following planned withdrawal of life-sustaining therapy, 54.0% (n = 760) were medically suitable for donation after circulatory death. In 438 cases where next of kin was approached, consent rates reached 47.5%. A total of 119 patients became actual organ donors. Only 66.2% (n = 503) of suitable patients were appropriately referred, resulting in 251 missed potential donors whose next of kin could not be approached regarding organ donation because referral occurred after initiation of withdrawal of life-sustaining therapy or not at all. The number of medically suitable patients who die within 2 hours of planned withdrawal of life-sustaining therapy is nearly six times higher than the number of actual organ donors, with the greatest loss of potential due to delayed referral until at the time of or after planned withdrawal of life-sustaining therapy. Intensive care teams are not meeting their ethical responsibility to recognize impending death and appropriately refer potential organ donors to the local organ procurement organization. In cases where patients had previously registered their consent decision, they were denied a healthcare right.

  18. Design and Development of a Miniaturized Percutaneously Deployable Wireless Left Ventricular Assist Device: Early Prototypes and Feasibility Testing.

    Science.gov (United States)

    Letzen, Brian; Park, Jiheum; Tuzun, Zeynep; Bonde, Pramod

    The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.

  19. Favorable circulatory system outcomes as adjuvant traditional Chinese medicine (TCM treatment for cerebrovascular diseases in Taiwan.

    Directory of Open Access Journals (Sweden)

    Hsienhsueh Elley Chiu

    Full Text Available This study searches the National Health Insurance Research Database (NHIRD used in a previous project, aiming for reconstructing possible cerebrovascular disease-related groups (DRG,and estimating the costs between cerebrovascular disease and related diseases.We conducted a nationwide retrospective cohort study in stroke inpatients, we examined the overall costs in 3 municipalities in Taiwan, by evaluating the possible costs of the expecting diagnosis related group (DRG by using the international classification of diseases version-9 (ICD-9 system, and the overall analysis of the re-admission population that received traditional Chinese medicine (TCM treatment and those who did not.The trend demonstrated that the non-participant costs were consistent with the ICD-9 categories (430 to 437 because similarities existed between years 2006 to 2007. Among the TCM patients, a wide variation and additional costs were found compared to non-TCM patients during these 2 years. The average re-admission duration was significantly shorter for TCM patients, especially those initially diagnosed with ICD 434 during the first admission. In addition, TCM patients demonstrated more severe general symptoms, which incurred high conventional treatment costs, and could result in re-admission for numerous reasons. However, in Disease 7 of ICD-9 category, representing the circulatory system was most prevalent in non-TCM inpatients, which was the leading cause of re-admission.We concluded that favorable circulatory system outcomes were in adjuvant TCM treatment inpatients, there were less re-admission for circulatory system events and a two-third reduction of re-admission within ICD-9 code 430 to 437, compared to non-TCM ones. However, there were shorter re-admission duration other than circulatory system events by means of unfavorable baseline condition.

  20. Carotid Doppler ultrasound findings in patients with left ventricular assist devices.

    Science.gov (United States)

    Cervini, Patrick; Park, Soon J; Shah, Dipesh K; Penev, Irina E; Lewis, Bradley D

    2010-12-01

    Left ventricular assist devices (LVADs) have been used to treat advanced heart failure refractory to medical management, as bridge therapy to myocardial recovery, as bridge therapy to cardiac transplantation, or as destination therapy for patients with unfavorable transplant candidacy. Neurologic complications are some of the most common and devastating complications in these patients. Preoperative carotid ultrasound is, therefore, a standard evaluation in patients at risk for cerebrovascular disease. Postoperative carotid artery Doppler sonography is performed in those patients with neurologic symptoms. It is likely, therefore, that sonographers, radiologists, and other physicians working in a center where LVADs are implanted will likely encounter a carotid artery Doppler study in this patient group. To our knowledge, the carotid Doppler findings in these patients have never been published. We review the Doppler ultrasound findings in 6 patients after LVAD insertion.

  1. Applying a soft-robotic glove as assistive device and training tool with games to support hand function after stroke: Preliminary results on feasibility and potential clinical impact.

    Science.gov (United States)

    Prange-Lasonder, Gerdienke B; Radder, Bob; Kottink, Anke I R; Melendez-Calderon, Alejandro; Buurke, Jaap H; Rietman, Johan S

    2017-07-01

    Recent technological developments regarding wearable soft-robotic devices extend beyond the current application of rehabilitation robotics and enable unobtrusive support of the arms and hands during daily activities. In this light, the HandinMind (HiM) system was developed, comprising a soft-robotic, grip supporting glove with an added computer gaming environment. The present study aims to gain first insight into the feasibility of clinical application of the HiM system and its potential impact. In order to do so, both the direct influence of the HiM system on hand function as assistive device and its therapeutic potential, of either assistive or therapeutic use, were explored. A pilot randomized clinical trial was combined with a cross-sectional measurement (comparing performance with and without glove) at baseline in 5 chronic stroke patients, to investigate both the direct assistive and potential therapeutic effects of the HiM system. Extended use of the soft-robotic glove as assistive device at home or with dedicated gaming exercises in a clinical setting was applicable and feasible. A positive assistive effect of the soft-robotic glove was proposed for pinch strength and functional task performance 'lifting full cans' in most of the five participants. A potential therapeutic impact was suggested with predominantly improved hand strength in both participants with assistive use, and faster functional task performance in both participants with therapeutic application.

  2. Cardiorespiratory interactions in neural circulatory control in humans.

    Science.gov (United States)

    Shamsuzzaman, A S; Somers, V K

    2001-06-01

    The reflex mechanisms and interactions described in this overview provide some explanation for the range of neural circulatory responses evident during changes in breathing. The effects described represent the integrated responses to activation of several reflex mechanisms, including peripheral and central chemoreflexes, arterial baroreflexes, pulmonary stretch receptors, and ventricular mechanoreceptors. These interactions occur on a dynamic basis and the transfer characteristics of any single interaction are, in all likelihood, also highly dynamic. Nevertheless, it is only by attempting to understand individual reflexes and their modulating influences that a more thorough understanding of the responses to complex phenomena such as hyperventilation, apnea, and obstructive sleep apnea can be better understood.

  3. Synergy of first principles modelling with predictive control for a biventricular assist device: In silico evaluation study.

    Science.gov (United States)

    Koh, Vivian C A; Yong Kuen Ho; Stevens, Michael C; Salamonsen, Robert F; Lovell, Nigel H; Lim, Einly

    2017-07-01

    Control for dual rotary left ventricular assist devices (LVADs) used as a biventricular assist device (BiVAD) is challenging. If the control system fails, flow imbalance between the systemic and the pulmonary circulations would result, subsequently leading to ventricular suction or pulmonary congestion. With the expectation that advanced control approaches such as model predictive control could address the challenges naturally and effectively, we developed a synergistic first principles model predictive controller (MPC) for the BiVAD. The internal model of the MPC is a simplified state-space model that has been developed and validated in a previous study. A single Frank-Starling (FS) control curve was used to define the target pump flow corresponding to the preload on each side of the heart. The MPC was evaluated in a validated numerical model using three clinical scenarios: blood loss, myocardial recovery, and exercise. Simulation results showed that the MPC was effective in adapting to changes in physiological states without causing ventricular suction or pulmonary congestion. The use of MPC for a BiVAD eliminates the need for two controllers of dual LVADs thus making the task of controller tuning easier.

  4. Mechanical Circulatory Support for Advanced Heart Failure: Are We about to Witness a New "Gold Standard"?

    Science.gov (United States)

    Capoccia, Massimo

    2016-12-12

    The impact of left ventricular assist devices (LVADs) for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs), based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs). The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial) and the HeartWare HVAD (centrifugal) rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal) is now emerging as the new promising device with encouraging preliminary results. There are now enough pumps on

  5. The attitudes of Australian radiography students towards the use of assistive transfer devices to reduce biomechanical stress in the clinical setting

    International Nuclear Information System (INIS)

    Ngo, Mark; Schneider-Kolsky, Michal; Baird, Marilyn

    2013-01-01

    The duties performed by radiographers, which includes transferring patients onto and off the examination table, can increase their risk of developing back and neck pain. This study used a survey to identify the assistive transfer devices Australian radiography undergraduate students are familiar with and have had practise using in the clinical setting. It also sought to determine whether students are being encouraged by other radiographers to use these devices during clinical training and if they would conform to practicing unsafe transfers if instructed to by senior staff. Results indicated that radiography students were familiar with the majority of the surveyed assistive devices such as the Patslide and X-ray cassette slider. Many of the students were unlikely to participate in unsafe work practices and were able to provide alternative methods of transferring patients. However, some of the respondents could be coerced into participating in unsafe patient transfers. Radiographers should therefore be vigilant in refraining from practicing unsafe transfer techniques as it could lead to students believing it is acceptable and emulating these practices in the work place

  6. Is exercise training safe and beneficial in patients receiving left ventricular assist device therapy?

    Science.gov (United States)

    Alsara, Osama; Perez-Terzic, Carmen; Squires, Ray W; Dandamudi, Sanjay; Miranda, William R; Park, Soon J; Thomas, Randal J

    2014-01-01

    Because a limited number of patients receive heart transplantation, alternative therapies, such as left ventricular assist device (LVAD) therapy, have emerged. Published studies have shown that LVAD implantation, by itself, improves exercise tolerance to the point where it is comparable to those with mild heart failure. The improvement in exercise capacity is maximally achieved 12 weeks after LVAD therapy and can continue even after explantation of the device. This effect varies, depending on the type of LVAD and exercise training. The available data in the literature on safety and benefits of exercise training in patients after LVAD implantation are limited, but the data that are available suggest that training trends to be safe and have an impact on exercise capacity in LVAD patients. Although no studies were identified on the role of cardiac rehabilitation programs in the management of LVAD patients, it appears that cardiac rehabilitation programs offer an ideal setting for the provision of supervised exercise training in this patient group.

  7. Left ventricular assist device: exercise capacity evolution and rehabilitation added value.

    Science.gov (United States)

    Lamotte, Michel X; Chimenti, Sara; Deboeck, Gael; Gillet, Alexis; Kacelenenbogen, Raymond; Strapart, Jonathan; Vandeneynde, Frédéric; Van Nooten, Guido; Antoine, Martine

    2018-06-01

    With more than 15,000 implanted patients worldwide and a survival rate of 80% at 1-year and 59% at 5-years, left ventricular assist device (LVAD) implantation has become an interesting strategy in the management of heart failure patients who are resistant to other kinds of treatment. There are limited data in the literature on the change over time of exercise capacity in LVAD patients, as well as limited knowledge about the beneficial effects that rehabilitation might have on these patients. Therefore, the aim of our study was to evaluate the evolution of exercise capacity on a cohort of patients implanted with the same device (HeartWare © ) and to analyse the potential impact of rehabilitation. Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation. We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme. Exercise capacity of patient implanted with a HeartWare © LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.

  8. Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

    Science.gov (United States)

    Gallagher, R. R.

    1974-01-01

    The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

  9. A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.

    Science.gov (United States)

    Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A

    2005-11-01

    While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.

  10. Grasp Assist Device with Automatic Mode Control Logic

    Science.gov (United States)

    Davis, Donald R. (Inventor); Ihrke, Chris A. (Inventor); Laske, Evan (Inventor)

    2018-01-01

    A system includes a glove, sensors, actuator assemblies, and controller. The sensors include load sensors which measure an actual grasping force and attitude sensors which determine a glove attitude. The actuator assembly provides a grasp assist force to the glove. Respective locations of work cells in the work environment and permitted work tasks for each work cell are programmed into the controller. The controller detects the glove location and attitude. A work task is selected by the controller for the location. The controller calculates a required grasp assist force using measured actual grasping forces from the load sensors. The required grasp assist force is applied via the glove using the actuator assembly to thereby assist the operator in performing the identified work task.

  11. Machines versus medication for biventricular heart failure: focus on the total artificial heart.

    Science.gov (United States)

    Arabia, Francisco A; Moriguchi, Jaime D

    2014-09-01

    The medical/surgical management of advanced heart failure has evolved rapidly over the last few decades. With better understanding of heart failure pathophysiology, new pharmacological agents have been introduced that have resulted in improvements in survival. For those patients that fail to improve, mechanical circulatory support with left ventricular assist devices and total artificial hearts (TAHs) have served as a beneficial bridge to transplantation. The TAH has continued to play a significant role as a bridge to transplantation in patients with biventricular failure and more selected indications that could not be completely helped with left ventricular assist devices. Improved survival with the TAH has resulted in more patients benefiting from this technology. Improvements will eventually lead to a totally implantable device that will permanently replace the failing human heart.

  12. Myocardial fibrosis and pro-fibrotic markers in end-stage heart failure patients during continuous-flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, Sjoukje I.; Nous, Fay M. A.; van Kuik, Joyce; van der Weide, Petra; Winkens, Bjorn; Kemperman, Hans; Huisman, Andre; Lahpor, Jaap R; de Weger, Roel A.; de Jonge, Nicolaas

    OBJECTIVES: During support with a left ventricular assist device (LVAD), partial reverse remodelling takes place in which fibrosis plays an important role. In this study, we analysed the histological changes and expression of fibrotic markers in patients with advanced heart failure (HF) during

  13. FEATURES OF LONG-TERM MECHANICAL CIRCULATORY SUPPORT WITH CONTINUOUS-FLOW PUMP

    Directory of Open Access Journals (Sweden)

    G. P. Itkin

    2012-01-01

    Full Text Available In a review of the comparative analysis of methods and tools for long-term mechanical circulatory support with continuous flow and pulsatile flow implantable pumps. Particular attention is paid to the choice of the optimal modes of the operation of pumps based on the physical principles of the interaction between a the steady flow of blood to the pulsatile mechanics of the heart chambers. 

  14. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    Science.gov (United States)

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid

    2009-04-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  15. Hypothermic Oxygenated Machine Perfusion in Porcine Donation After Circulatory Determination of Death Liver Transplant

    NARCIS (Netherlands)

    Fondevila, Constantino; Hessheimer, Amelia J.; Maathuis, Mark-Hugo J.; Munoz, Javier; Taura, Pilar; Calatayud, David; Leuvenink, Henri; Rimola, Antoni; Garcia-Valdecasas, Juan C.; Ploeg, Rutger J.

    2012-01-01

    Background. Livers from donation after circulatory determination-of-death (DCD) donors suffer ischemic injury during a preextraction period of cardiac arrest and are infrequently used for transplantation; they have the potential, however, to considerably expand the donor pool. We aimed to determine

  16. Comparison of outcomes of kidney transplantation from donation after brain death, donation after circulatory death, and donation after brain death followed by circulatory death donors.

    Science.gov (United States)

    Chen, Guodong; Wang, Chang; Ko, Dicken Shiu-Chung; Qiu, Jiang; Yuan, Xiaopeng; Han, Ming; Wang, Changxi; He, Xiaoshun; Chen, Lizhong

    2017-11-01

    There are three categories of deceased donors of kidney transplantation in China, donation after brain death (DBD), donation after circulatory death (DCD), and donation after brain death followed by circulatory death (DBCD) donors. The aim of this study was to compare the outcomes of kidney transplantation from these three categories of deceased donors. We retrospectively reviewed 469 recipients who received deceased kidney transplantation in our hospital from February 2007 to June 2015. The recipients were divided into three groups according to the source of their donor kidneys: DBD, DCD, or DBCD. The primary endpoints were delayed graft function (DGF), graft loss, and patient death. The warm ischemia time was much longer in DCD group compared to DBCD group (18.4 minutes vs 12.9 minutes, P < .001). DGF rate was higher in DCD group than in DBD and DBCD groups (22.5% vs 10.2% and 13.8%, respectively, P = .021). Urinary leakage was much higher in DCD group (P = .049). Kaplan-Meier analysis showed that 1-, 2-, and 3-year patient survivals were all comparable among the three groups. DBCD kidney transplantation has lower incidences of DGF and urinary leakage than DCD kidney transplant. However, the overall patient and graft survival were comparable among DBD, DCD, and DBCD kidney transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    Science.gov (United States)

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by

  18. Assistive Technology: What Physical Educators Need to Know

    Science.gov (United States)

    Laughlin, Michael K.; Murata, Nathan M.; Gonnelli, Michele; Larranaga, John

    2018-01-01

    Assistive technology supplements and supports the learning of students with disabilities in school and at home. Thanks to federal mandates, students with disabilities receive consideration for assistive technology devices and services--the tools and supports needed to achieve determined learning outcomes. Assistive technology devices and services…

  19. Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices

    OpenAIRE

    Tereso,Ana; Martins,Maria Manuel; Santos,Cristina Peixoto

    2015-01-01

    IntroductionNowadays Knee Osteoarthritis (KOA) affects a large percentage of the elderly, and one solution is to perform a Total Knee Arthroplasty (TKA). In this paper, one intends to study the gait and posture of these patients after the TKA, while walking with three assistive devices (ADs) (crutches, standard walker (SW) and rollator with forearm supports (RFS)).MethodsEleven patients were evaluated in 2 phases: 5 days and 15 days after surgery. This evaluation was conducted with two inerti...

  20. Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction

    Directory of Open Access Journals (Sweden)

    Thomas Platz

    2016-01-01

    Full Text Available Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL. Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™. Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™ indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard.

  1. Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction

    Science.gov (United States)

    Gillner, Annett; Borgwaldt, Nicole; Kroll, Sylvia; Roschka, Sybille

    2016-01-01

    Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard. PMID:27610382

  2. Intraoperative care for aortic surgery using circulatory arrest.

    Science.gov (United States)

    Fernández Suárez, Félix Ezequiel; Fernández Del Valle, David; González Alvarez, Adrián; Pérez-Lozano, Blanca

    2017-05-01

    The total circulatory arrest (CA) is necessary to achieve optimal surgical conditions in certain aortic pathologies, especially in those affecting the ascending aorta and aortic arch. During this procedure it is necessary to protect all the organs of ischemia, especially those of the central nervous system and for this purpose several strategies have been developed. The first and most important protective method is systemic hypothermia. The degree of hypothermia and the route of application have been evolving and currently tend to use moderate hypothermia (MH) (20.1-28 °C) associated with unilateral or bilateral selective cerebral perfusion methods. In this way the neurological results are better, the interval of security is greater and the times of extracorporeal circulation are smaller. Even so, it is necessary to take into account that there is the possibility of ischemia in the lower part of the body, especially of the abdominal viscera and the spinal cord, therefore the time of circulatory stop should be limited and not to exceed 80 minutes. Evidence of possible neurological drug protection is very weak and only mannitol, magnesium, and statins can produce some benefit. Inhalational anesthetics and some intravenous seem to have advantages, but more studies would be needed to test their long-term benefit. Other important parameters to be monitored during these procedures are blood glucose, anemia and coagulation disorders and acid-base balance. The recommended monitoring is common in complex cardiovascular procedures and it is of special importance the neurological monitoring that can be performed with several techniques, although currently the most used are Bispectral Index (BIS) and Near-Infrared Spectroscopy (NIRS). It is also essential to monitor the temperature routinely at the nasopharyngeal and bladder level and it is important to control coagulation with rotational thromboelastometry (ROTEM).

  3. Development of brake assist system. Summary of hydraulic brake assist system; Brake assist system no kaihatsu. Ekiatsushiki brake assist system no gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    Hara, M; Ota, M; Shimizu, S [Toyota, Motor Corp., Aichi (Japan)

    1997-10-01

    We have already developed vacuum-booster-type Brake Assist System that supplies additional braking power when panic braking is recognized. We are convinced that the expansion of Brake Assist System will become more important issue in the future. Therefore we have developed hydraulic Brake Assist System with increasing its controllability and reducing its discomfort. This system have a brake pressure sensor to detect emergency braking operation and an antilock device to supply additional braking power. 8 refs., 11 figs.

  4. Portable vibration-assisted filtration device for on-site isolation of blood cells or pathogenic bacteria from whole human blood.

    Science.gov (United States)

    Kim, Yong Tae; Park, Kyun Joo; Kim, Seyl; Kim, Soon Ae; Lee, Seok Jae; Kim, Do Hyun; Lee, Tae Jae; Lee, Kyoung G

    2018-03-01

    Isolation of specific cells from whole blood is important to monitor disease prognosis and diagnosis. In this study, a vibration-assisted filtration (VF) device has been developed for isolation and recovery of specific cells such as leukocytes and pathogenic bacteria from human whole blood. The VF device is composed of three layers which was fabricated using injection molding with cyclic olefin copolymer (COC) pellets consisting of: a top layer with coin-type vibration motor (Ф = 10mm), a middle plate with a 1μm or 3μm-pore filter membrane to separate of Staphylococcus aureus (S. aureus) cells or leukocytes (i.e. white blood cells) respectively, and a bottom chamber with conical-shaped microstructure. One milliliter of human whole blood was injected into a sample loading chamber using a 3μm-pore filter equipped in the VF device and the coin-type vibration motor applied external vibration force by generating a rotational fluid which enhances the filtration velocity due to the prevention of the cell clogging on the filter membrane. The effluent blood such as erythrocytes, platelet, and plasma was collected at the bottom chamber while the leukocytes were sieved by the filter membrane. The vibration-assisted leukocyte separation was able to finish within 200s while leukocyte separation took 1200s without vibration. Moreover, we successfully separated S. aureus from human whole blood using a 1μm-pore filter equipped VF device and it was further confirmed by genetic analysis. The proposed VF device provides an advanced cell separation platform in terms of simplicity, fast separation, and portability in the fields of point-of-care diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  6. Perioperative Care of the Patient With the Total Artificial Heart.

    Science.gov (United States)

    Yaung, Jill; Arabia, Francisco A; Nurok, Michael

    2017-05-01

    Advanced heart failure continues to be a leading cause of morbidity and mortality despite improvements in pharmacologic therapy. High demand for cardiac transplantation and shortage of donor organs have led to an increase in the utilization of mechanical circulatory support devices. The total artificial heart is an effective biventricular assist device that may be used as a bridge to transplant and that is being studied for destination therapy. This review discusses the history, indications, and perioperative management of the total artificial heart with emphasis on the postoperative concerns.

  7. Quality of Life, Depression, and Anxiety in Ventricular Assist Device Therapy: Longitudinal Outcomes for Patients and Family Caregivers.

    Science.gov (United States)

    Bidwell, Julie T; Lyons, Karen S; Mudd, James O; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Grady, Kathleen L; Lee, Christopher S

    Patients who receive ventricular assist device (VAD) therapy typically rely on informal caregivers (family members or friends) to assist them in managing their device. The purpose of this study is to characterize changes in person-oriented outcomes (quality of life [QOL], depression, and anxiety) for VAD patients and their caregivers together from pre-implantation to 3 months post-implantation. This was a formal interim analysis from an ongoing prospective study of VAD patients and caregivers (n = 41 dyads). Data on person-oriented outcomes (QOL: EuroQol 5 Dimensions Visual Analog Scale; depression: Patient Health Questionnaire-8; anxiety: Brief Symptom Inventory) were collected at 3 time points (just prior to implantation and at 1 and 3 months post-implantation). Trajectories of change for patients and caregivers on each measure were estimated using latent growth modeling with parallel processes. Patients' QOL improved significantly over time, whereas caregiver QOL worsened. Depression and anxiety also improved significantly among patients but did not change among caregivers. There was substantial variability in change on all outcomes for both patients and their caregivers. This is the first quantitative study of VAD patient-caregiver dyads in modern devices that describes change in person-oriented outcomes from pre-implantation to post-implantation. This work supports the need for future studies that account for the inherent relationships between patient and caregiver outcomes and examine variability in patient and caregiver responses to VAD therapy.

  8. Mechanical Circulatory Support for Advanced Heart Failure: Are We about to Witness a New “Gold Standard”?

    Directory of Open Access Journals (Sweden)

    Massimo Capoccia

    2016-12-01

    Full Text Available The impact of left ventricular assist devices (LVADs for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs, based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs. The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial and the HeartWare HVAD (centrifugal rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal is now emerging as the new promising device with encouraging preliminary results. There are now

  9. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    Science.gov (United States)

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  10. Minimal alteration in the ratio of circulatory fetal DNA to fetal corticotropin-releasing hormone mRNA level in preeclampsia.

    Science.gov (United States)

    Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe

    2006-01-01

    We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.

  11. High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement.

    Science.gov (United States)

    Imamura, Teruhiko; Kinugawa, Koichiro; Kinoshita, Osamu; Nawata, Kan; Ono, Minoru

    2016-03-01

    Although the right ventricular stroke work index (RVSWI) is a good index for RV function, a low RVSWI is not necessarily an indicator for the need for a right ventricular assist device at the time of left VAD implantation. We here aimed to determine a more precise indicator for the need for a biventricular assist device (BiVAD). In total, 116 patients (mean age, 38 ± 14 years), who underwent hemodynamic assessments preoperatively including 12 BiVAD patients, and had been followed at our institute from 2003 to 2015, were included. Multivariate logistic regression analysis indicated that RVSWI and pulmonary vascular resistance (PVR) were independent predictors of BiVAD requirement (P 5 g/m, PVR 5, PVR > 3.7), (3) RV failure (RVSWI 3.7), and examined. Most of the patients in Group 4 (75 %), with acutely depressed hemodynamics and inflammatory responses in the myocardium, required BiVAD. Overall, patients with BiVAD had a worse survival rate as compared with those with LVAD alone. In conclusion, high PVR in addition to low RVSWI effectively predicts BiVAD requirement.

  12. Outcomes of ventricular assist device implantation in children and young adults: the Melbourne experience.

    Science.gov (United States)

    Shi, William Y; Marasco, Silvana F; Saxena, Pankaj; d'Udekem, Yves; Yong, Matthew S; Mitnovetski, Sergei; Brizard, Christian P; McGiffin, David C; Weintraub, Robert G; Konstantinov, Igor E

    2016-12-01

    We evaluated our experience with ventricular assist device (VAD) implantation in children and young adults. A total of 64 patients underwent VAD implantation in two centres. The mean age was 15 ± 7.2 years. Thirty-five (55%) patients were under 18 years of age. Devices implanted included the Thoratec Paracorporeal in 30 (47%) patients, Berlin Heart EXCOR in 11 (17%) and VentrAssist in 14 (22%). The diagnosis was cardiomyopathy in 53, congenital heart disease in 11, and graft failure in four patients. There were 10 (16%) in-hospital deaths. Mortality was higher in patients <18 years of age (26% compared with 3.4% for those ≥18 years, P = 0.02). The use of extracorporeal membrane oxygenation prior to VAD implantation was associated with higher mortality (P = 0.006). Seventeen (27%) patients experienced stroke. Nine patients (14%) required change of VAD because of thrombosis. Transplantation was performed in 44 patients after a mean of 131 ± 141 days on VAD, 11 patients died without transplantation and three patients currently await transplantation. The VAD was explanted in six patients because of recovery. Overall survival from VAD implantation was 69% and 61% at 5 and 10 years, respectively. The 5-year post-transplant survival for those bridged with VAD support was 91% and was comparable with a cohort of patients who did not receive a pre-transplant VAD. Children requiring pre-transplant VAD support have a higher mortality and morbidity compared with young adults. Survival after heart transplantation those supported with VADs was similar to patients of similar age who did not require pre-transplant support. © 2015 Royal Australasian College of Surgeons.

  13. Exploration of Two Training Paradigms Using Forced Induced Weight Shifting With the Tethered Pelvic Assist Device to Reduce Asymmetry in Individuals After Stroke: Case Reports.

    Science.gov (United States)

    Bishop, Lauri; Khan, Moiz; Martelli, Dario; Quinn, Lori; Stein, Joel; Agrawal, Sunil

    2017-10-01

    Many robotic devices in rehabilitation incorporate an assist-as-needed haptic guidance paradigm to promote training. This error reduction model, while beneficial for skill acquisition, could be detrimental for long-term retention. Error augmentation (EA) models have been explored as alternatives. A robotic Tethered Pelvic Assist Device has been developed to study force application to the pelvis on gait and was used here to induce weight shift onto the paretic (error reduction) or nonparetic (error augmentation) limb during treadmill training. The purpose of these case reports is to examine effects of training with these two paradigms to reduce load force asymmetry during gait in two individuals after stroke (>6 mos). Participants presented with baseline gait asymmetry, although independent community ambulators. Participants underwent 1-hr trainings for 3 days using either the error reduction or error augmentation model. Outcomes included the Borg rating of perceived exertion scale for treatment tolerance and measures of force and stance symmetry. Both participants tolerated training. Force symmetry (measured on treadmill) improved from pretraining to posttraining (36.58% and 14.64% gains), however, with limited transfer to overground gait measures (stance symmetry gains of 9.74% and 16.21%). Training with the Tethered Pelvic Assist Device device proved feasible to improve force symmetry on the treadmill irrespective of training model. Future work should consider methods to increase transfer to overground gait.

  14. Left ventricular assist device exchange: the Toronto General Hospital experience.

    Science.gov (United States)

    Tsubota, Hideki; Ribeiro, Roberto V P; Billia, Filio; Cusimano, Robert J; Yau, Terrence M; Badiwala, Mitesh V; Stansfield, William E; Rao, Vivek

    2017-08-01

    As support times for left ventricular assist devices (LVADs) become longer, several complications requiring device exchange may occur. To our knowledge, this is the first Canadian report regarding implantable LVAD exchange. We retrospectively reviewed the cases of consecutive, unique patients implanted with an LVAD between June 2006 and October 2015 at Toronto General Hospital. In total, 122 patients were impanted with an LVAD during the study period. Eight patients required LVAD exchange, and 1 patient had 2 replacements (9 of 122, 7.3%). There were 7 HeartMate II (HMII), 1 HVAD and 1 DuraHeart pumps exchanged. Two of these exchanges occurred early at the time of initial implant, whereas 7 occurred late (range 8-623 d). Six exchanges were made owing to pump thrombosis. Of the 3 exchanges made for other causes, 1 HMII exchange was owing to a driveline fracture, 1 DuraHeart patient had early inflow obstruction requiring exchange to HMII at the initial implant, and the third had a suspected inflow obstruction with no evidence of thrombosis at the time of the procedure. The mean support time before exchange was 225 days, and time from exchange to transplant, death or ongoing support was 245 days. Three patients were successfully bridged to transplant, and at the time of data collection 2 were supported awaiting transplant. Three patients died after a mean duration of 394.3 days (range 78-673 d) of support postreplacement. Four cases were successfully performed using a subcostal approach. Pump thrombosis is the most common cause for LVAD exchange, which can be performed with acceptable morbidity and mortality. The subcostal approach may be the preferred procedure for an HMII exchange when indicated.

  15. Surgical thromboendarterectomy for chronic thromboembolic pulmonary hypertension using circulatory arrest with selective antegrade cerebral perfusion

    NARCIS (Netherlands)

    Zeebregts, CJAM; Dossche, KM; Morshuis, WJ; Knaepen, PJ; Schepens, MAAM

    The use of circulatory arrest with selective antegrade cerebral perfusion is described in a 59-year-old man who underwent thrombendarterectomy for chronic thromboembolic pulmonary hypertension. The postoperative course was uneventful. The described surgical technique may prevent the patient from

  16. Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients

    DEFF Research Database (Denmark)

    Jung, Mette Holme; Houston, Brian; Russell, Stuart D

    2017-01-01

    of the 2 sub-maximal tests was determined by randomization. Both patient and physician were blinded to the sequence. Exercise duration, oxygen consumption (VO2) and rate of perceived exertion (RPE), using the Borg scale (score 6 to 20), were recorded. RESULTS: Nineteen patients (all with a HeartMate II...... ventricular assist device) completed 57 exercise tests. Baseline pump speed was 9,326 ± 378 rpm. At AT, workload was 63 ± 26 W (25 to 115 W) and VO2 was 79 ± 14% of maximum. Exercise duration improved by 106 ± 217 seconds (~13%) in Speedinc compared with Speedbase (837 ± 358 vs 942 ± 359 seconds; p = 0...

  17. Circulatory Responses to Operative Stress in Females with Gestosis

    Directory of Open Access Journals (Sweden)

    I. V. Mikhno

    2007-01-01

    Full Text Available Objective: to study the specific features of hemodynamic responses in females with gestosis in the perioperative period; to evaluate the impact of intensive care on the basis of co-administration of dalargin, dexamethasone, pen-toxifylline, and reamberin.Materials and methods. A Diamant KM-AP-01 rheograph (Saint Petersburg was used to study hemodynamic parameters in 142 patients in whom surgical delivery was made under spinal anesthesia. A control group comprised 30 patients with uncomplicated pregnancy; Group 1 included 26 females with moderate gestosis; Group 2 consisted of 27 females with moderate gestosis who received the developed intensive care regimen; Group 3 comprised 29 females with severe gestosis; Group 4 included 30 females to whom the developed intensive care regimen was applied on the basis of the concurrent use of dalargin, dexamethasone, pentoxifylline, and reamberin.Results: A neurogenic mechanism prevails in females with moderate gestosis. The decreased baseline cardiac index is mostly due to a high postload. Surgical stress does not deteriorate postoperative circulatory parameters, which suggests that females with moderate gestosis have adequate capacities for self-regulation. As gestosis progresses to a severe degree, a role of humoral mechanisms increases in the maintenance of arteriolar spasm. Arteriolar spasm and hypokinetic hemodynamics are retained within 5 postoperative days, which is indicative of the inadequacy of self-regulation and compensatory mechanisms in overcoming two stressors: severe gestosis and surgical aggression.Conclusion: the intensive care regimen developed on the basis of combined use of dalargin, dexamethasone, pentoxifylline, and reamberin favors a more intensive (the promptest normalization of circulatory parameters after surgical delivery in females with moderate and severe gestosis. 

  18. Clinical manifestations and management of left ventricular assist device-associated infections.

    Science.gov (United States)

    Nienaber, Juhsien Jodi C; Kusne, Shimon; Riaz, Talha; Walker, Randall C; Baddour, Larry M; Wright, Alan J; Park, Soon J; Vikram, Holenarasipur R; Keating, Michael R; Arabia, Francisco A; Lahr, Brian D; Sohail, M Rizwan

    2013-11-01

    Infection is a serious complication of left ventricular assist device (LVAD) therapy. Published data regarding LVAD-associated infections (LVADIs) are limited by single-center experiences and use of nonstandardized definitions. We retrospectively reviewed 247 patients who underwent continuous-flow LVAD implantation from January 2005 to December 2011 at Mayo Clinic campuses in Minnesota, Arizona, and Florida. LVADIs were defined using the International Society for Heart and Lung Transplantation criteria. We identified 101 episodes of LVADI in 78 patients (32%) from this cohort. Mean age (± standard deviation [SD]) was 57±15 years. The majority (94%) underwent Heartmate II implantation, with 62% LVADs placed as destination therapy. The most common type of LVADIs were driveline infections (47%), followed by bloodstream infections (24% VAD related, and 22% non-VAD related). The most common causative pathogens included gram-positive cocci (45%), predominantly staphylococci, and nosocomial gram-negative bacilli (27%). Almost half (42%) of the patients were managed by chronic suppressive antimicrobial therapy. While 14% of the patients had intraoperative debridement, only 3 underwent complete LVAD removal. The average duration (±SD) of LVAD support was 1.5±1.0 years. At year 2 of follow-up, the cumulative incidence of all-cause mortality was estimated to be 43%. Clinical manifestations of LVADI vary on the basis of the type of infection and the causative pathogen. Mortality remained high despite combined medical and surgical intervention and chronic suppressive antimicrobial therapy. Based on clinical experiences, a management algorithm for LVADI is proposed to assist in the decision-making process.

  19. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network

    OpenAIRE

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network i...

  20. Study of shape memory alloy fibers for the development of artificial myocardium.

    Science.gov (United States)

    Hassoulas, Ioannis A; Ladopoulos, Vlassios S; Kalogerakos, Paris-Dimitrios K

    2010-01-01

    Circulatory support devices are employed to treat heart failure. Such a device could be made from shape memory alloy (SMA) fibers. These Ni-Ti fibers contract when electric current flows through them, thus resembling artificial muscles. An artificial myocardium device made from SMA fibers can directly compress the epicardial surface of a failing heart, thus contributing to the pumping action. Unlike modern mechanical circulatory support devices, there is no blood-contacting surface to provoke thromboembolism, hemorrhage, inflammatory response or hemolysis. The experimental setup permitted a detailed study of a sample SMA fiber with great accuracy while the ambient temperature was controlled to resemble that of the human body. The current profile through the fiber was controlled (current shaping, CS) by a microcontroller and a portable computer. Parameters such as strain, contraction and relaxation velocities and the effect of ambient temperature were measured. The contraction and relaxation velocities were measured after applying various effective currents. It was found that the contraction velocity could be manipulated to reach that of the healthy myocardium through CS. On the other hand, the relaxation velocity was independent of the contraction velocity. A cardiac assist device can be made from SMA fibers. More studies need to be conducted in this direction.

  1. Impact of the telephone assistive device (TAD) on stuttering severity while speaking on the telephone.

    Science.gov (United States)

    Chambers, Nola

    2009-01-01

    There is extensive experimental evidence that altered auditory feedback (AAF) can have a clinically significant effect on the severity of speech symptoms in people who stutter. However, there is less evidence regarding whether these experimental effects can be observed in naturalistic everyday settings particularly when using the telephone. This study aimed to investigate the effectiveness of the Telephone Assistive Device (TAD), which is designed to provide AAF on the telephone to people who stutter, on reducing stuttering severity. Nine adults participated in a quasi-experimental study. Stuttering severity was measured first without and then with the device in participants' naturalistic settings while making and receiving telephone calls (immediate benefit). Participants were then allowed a week of repeated use of the device following which all measurements were repeated (delayed benefit). Overall, results revealed significant immediate benefits from the TAD in all call conditions. Delayed benefits in received and total calls were also significant. There was substantial individual variability in response to the TAD but none of the demographic or speech-related factors measured in the study were found to significantly impact the benefit (immediate or delayed) derived from the TAD. Results have implications for clinical decision making for adults who stutter.

  2. Mechanisms and clinical applications of the vacuum-assisted closure (VAC) Device: a review.

    Science.gov (United States)

    Venturi, Mark L; Attinger, Christopher E; Mesbahi, Ali N; Hess, Christopher L; Graw, Katherine S

    2005-01-01

    The use of sub-atmospheric pressure dressings, available commercially as the vacuum-assisted closure (VAC) device, has been shown to be an effective way to accelerate healing of various wounds. The optimal sub-atmospheric pressure for wound healing appears to be approximately 125 mm Hg utilizing an alternating pressure cycle of 5 minutes of suction followed by 2 minutes off suction. Animal studies have demonstrated that this technique optimizes blood flow, decreases local tissue edema, and removes excessive fluid from the wound bed. These physiologic changes facilitate the removal of bacteria from the wound. Additionally, the cyclical application of sub-atmospheric pressure alters the cytoskeleton of the cells in the wound bed, triggering a cascade of intracellular signals that increases the rate of cell division and subsequent formation of granulation tissue. The combination of these mechanisms makes the VAC device an extremely versatile tool in the armamentarium of wound healing. This is evident in the VAC device's wide range of clinical applications, including treatment of infected surgical wounds, traumatic wounds, pressure ulcers, wounds with exposed bone and hardware, diabetic foot ulcers, and venous stasis ulcers. VAC has also proven useful in reconstruction of wounds by allowing elective planning of the definitive reconstructive surgery without jeopardizing the wound or outcome. Furthermore, VAC has significantly increased the skin graft success rate when used as a bolster over the freshly skin-grafted wound. VAC is generally well tolerated and, with few contraindications or complications, is fast becoming a mainstay of current wound care.

  3. Substrate type < 111 >-Cu{sub 2}O/<0001 >-ZnO photovoltaic device prepared by photo-assisted electrodeposition

    Energy Technology Data Exchange (ETDEWEB)

    Zamzuri, Mohd, E-mail: zamzuri@tf.me.tut.ac.jp [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan); School of Manufacturing Eng., Universiti Malaysia Perlis, Kampus Tetap Pauh Putra, Jln Arau-Changlun, 02600 Arau, Perlis (Malaysia); Sasano, Junji [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan); Mohamad, Fariza Binti [Faculty of Electrical & Electronic Eng., University Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor (Malaysia); Izaki, Masanobu [Department of Mechanical Eng., Toyohashi University of Technology, 1-1 Hibari Gaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan)

    2015-11-30

    The substrate-type < 0001 > ZnO/<111 > Cu{sub 2}O photovoltaic (PV) device has been constructed by electrodeposition of a < 111 >-p-Cu{sub 2}O layer on an Au(111)/Si wafer substrate followed by stacking the n-ZnO layer by electrodeposition during light irradiation in aqueous solutions. The PV device was fabricated by stacking the Al:ZnO-window by sputtering and the top Al electrode by vacuum evaporation. The < 0001 >-ZnO layer was composed of aggregates of hexagonal columnar grains grown in the direction normal to the surface, and pores could be observed between the ZnO grains at the deposition time last 1800 s. The < 0001 >-ZnO/<111 >-Cu{sub 2}O PV device showed a photovoltaic performance under AM1.5 illumination, and showed the improved short-circuit current density of 5.87 mA cm{sup −2} by stacking the AZO-TCO due to the increase in the diffusion length of the carrier. - Highlights: • Substrate type ZnO/Cu{sub 2}O photovoltaic devices only by electrodeposition • ZnO layer was stacked on the Cu{sub 2}O layer by photo-assisted electrodeposition. • AZO/ZnO/Cu{sub 2}O photovoltaic devices with a short-circuit current density of 5.87 mA cm{sup −2}.

  4. The Effect of the Usage of Computer-Based Assistive Devices on the Functioning and Quality of Life of Individuals Who Are Blind or Have Low Vision

    Science.gov (United States)

    Rosner, Yotam; Perlman, Amotz

    2018-01-01

    Introduction: The Israel Ministry of Social Affairs and Social Services subsidizes computer-based assistive devices for individuals with visual impairments (that is, those who are blind or have low vision) to assist these individuals in their interactions with computers and thus to enhance their independence and quality of life. The aim of this…

  5. Outcome of pancreas transplantation from donation after circulatory death compared to donation after brain death

    NARCIS (Netherlands)

    van Loo, Ellen S.; Krikke, Christina; Hofker, Hendrik S.; Berger, Stefan P.; Leuvenink, Henri G. D.; Pol, Robert A.

    Introduction: To overcome the gap of organ shortage grafts from donation after circulatory death (DCD) can be used. This review evaluates the outcomes after DCD pancreas donation compared to donation after brain death (DBD). Materials and methods: A literature search was performed using Medline,

  6. Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models.

    Science.gov (United States)

    Di Molfetta, Arianna; Ferrari, Gianfranco; Filippelli, Sergio; Fresiello, Libera; Iacobelli, Roberta; Gagliardi, Maria G; Amodeo, Antonio

    2016-05-01

    Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy

  7. The pharmacotherapy of the HeartMate II, a continuous flow left ventricular assist device, in patients with advanced heart failure: integration of disease, device, and drug.

    Science.gov (United States)

    Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M

    2010-10-01

    Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.

  8. Fabrication of three-dimensional scaffolds using precision extrusion deposition with an assisted cooling device.

    Science.gov (United States)

    Hamid, Q; Snyder, J; Wang, C; Timmer, M; Hammer, J; Guceri, S; Sun, W

    2011-09-01

    In the field of biofabrication, tissue engineering and regenerative medicine, there are many methodologies to fabricate a building block (scaffold) which is unique to the target tissue or organ that facilitates cell growth, attachment, proliferation and/or differentiation. Currently, there are many techniques that fabricate three-dimensional scaffolds; however, there are advantages, limitations and specific tissue focuses of each fabrication technique. The focus of this initiative is to utilize an existing technique and expand the library of biomaterials which can be utilized to fabricate three-dimensional scaffolds rather than focusing on a new fabrication technique. An expanded library of biomaterials will enable the precision extrusion deposition (PED) device to construct three-dimensional scaffolds with enhanced biological, chemical and mechanical cues that will benefit tissue generation. Computer-aided motion and extrusion drive the PED to precisely fabricate micro-scaled scaffolds with biologically inspired, porosity, interconnectivity and internal and external architectures. The high printing resolution, precision and controllability of the PED allow for closer mimicry of tissues and organs. The PED expands its library of biopolymers by introducing an assisting cooling (AC) device which increases the working extrusion temperature from 120 to 250 °C. This paper investigates the PED with the integrated AC's capabilities to fabricate three-dimensional scaffolds that support cell growth, attachment and proliferation. Studies carried out in this paper utilized a biopolymer whose melting point is established to be 200 °C. This polymer was selected to illustrate the newly developed device's ability to fabricate three-dimensional scaffolds from a new library of biopolymers. Three-dimensional scaffolds fabricated with the integrated AC device should illustrate structural integrity and ability to support cell attachment and proliferation.

  9. Fabrication of three-dimensional scaffolds using precision extrusion deposition with an assisted cooling device

    International Nuclear Information System (INIS)

    Hamid, Q; Snyder, J; Wang, C; Guceri, S; Sun, W; Timmer, M; Hammer, J

    2011-01-01

    In the field of biofabrication, tissue engineering and regenerative medicine, there are many methodologies to fabricate a building block (scaffold) which is unique to the target tissue or organ that facilitates cell growth, attachment, proliferation and/or differentiation. Currently, there are many techniques that fabricate three-dimensional scaffolds; however, there are advantages, limitations and specific tissue focuses of each fabrication technique. The focus of this initiative is to utilize an existing technique and expand the library of biomaterials which can be utilized to fabricate three-dimensional scaffolds rather than focusing on a new fabrication technique. An expanded library of biomaterials will enable the precision extrusion deposition (PED) device to construct three-dimensional scaffolds with enhanced biological, chemical and mechanical cues that will benefit tissue generation. Computer-aided motion and extrusion drive the PED to precisely fabricate micro-scaled scaffolds with biologically inspired, porosity, interconnectivity and internal and external architectures. The high printing resolution, precision and controllability of the PED allow for closer mimicry of tissues and organs. The PED expands its library of biopolymers by introducing an assisting cooling (AC) device which increases the working extrusion temperature from 120 to 250 deg. C. This paper investigates the PED with the integrated AC's capabilities to fabricate three-dimensional scaffolds that support cell growth, attachment and proliferation. Studies carried out in this paper utilized a biopolymer whose melting point is established to be 200 deg. C. This polymer was selected to illustrate the newly developed device's ability to fabricate three-dimensional scaffolds from a new library of biopolymers. Three-dimensional scaffolds fabricated with the integrated AC device should illustrate structural integrity and ability to support cell attachment and proliferation.

  10. Stroke Risk and Mortality in Patients With Ventricular Assist Devices.

    Science.gov (United States)

    Parikh, Neal S; Cool, Joséphine; Karas, Maria G; Boehme, Amelia K; Kamel, Hooman

    2016-11-01

    Ventricular assist devices (VADs) have advanced the management of end-stage heart failure. However, these devices are associated with hemorrhagic and thrombotic complications, including stroke. We assessed the incidence, risk factors, and outcomes of ischemic and hemorrhagic stroke after VAD placement. Using administrative claims data from acute care hospitals in California, Florida, and New York from 2005 to 2013, we identified patients who underwent VAD placement, defined by the International Classification of Diseases, Ninth Revision, Clinical Modification code 37.66. Ischemic and hemorrhagic strokes were identified by previously validated coding algorithms. We used survival statistics to determine the incidence rates and Cox proportional hazard analyses to examine the associations. Among 1813 patients, we identified 201 ischemic strokes and 116 hemorrhagic strokes during 3.4 (±2.0) years of follow-up after implantation of a VAD. The incidence of stroke was 8.7% per year (95% confidence interval [CI], 7.7-9.7). The annual incidence of ischemic stroke (5.5%; 95% CI, 4.8-6.4) was nearly double that of hemorrhagic stroke (3.1%; 95% CI, 2.6-3.8). Women faced a higher hazard of stroke than men (hazard ratio, 1.6; 95% CI, 1.2-2.1), particularly hemorrhagic stroke (hazard ratio, 2.2; 95% CI, 1.4-3.4). Stroke was strongly associated with subsequent in-hospital mortality (hazard ratio, 6.1; 95% CI, 4.6-7.9). The incidence of stroke after VAD implantation was 8.7% per year, and incident stroke was strongly associated with subsequent in-hospital mortality. Notably, ischemic stroke occurred at nearly twice the rate of hemorrhagic stroke. Women seemed to face a higher risk for hemorrhagic stroke than men. © 2016 American Heart Association, Inc.

  11. Relevances between cerebral circulatory disorder and symptom in idiopathic normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Takeuchi, Totaro; Shimizu, Tsuneo; Watanabe, Kazuo

    2010-01-01

    The subjects were shunt-effective idiopathic normal pressure hydrocephalus (iNPH) 40 patients. Before and one year after surgery, measurements of the cerebral circulatory dynamics (the cerebral blood flow pattern by region of interest (ROI) setting using 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT)), and an evaluation of symptoms (gait disturbance: G, dementia: D, urinary incontinence: U) by grading scale (JNPHGS-R). Preoperative cerebral circulation and symptoms: As for the each symptoms and blood flow patterns, the seventies of G (p=0.017) in whole cortex non-reduction group (thalamus-basal ganglia reduction group) and D (p=0.021) in whole cortex reduction group were obviously high compared with other symptoms particularly. Circulation and symptoms one year after surgery: As the circulatory dynamics at different improvement sites and each symptoms, it was obviously mild for G (p=0.003) in the group with an increased only thalamus-basal ganglia blood flow and increased both whole cortex and thalamus-basal ganglia blood flow and tend to mild for D (p=0.091) in the group with an increased only whole cortex blood flow and increased both whole cortex and thalamus-basal ganglia blood flow compared with other symptoms. (author)

  12. Handcrafted Vacuum-Assisted Device for Skin Ulcers Treatment Versus Traditional Therapy, Randomized Controlled Trial.

    Science.gov (United States)

    Gonzalez, Israel Gonzalez; Angel, Medina Andrade Luis; Baez, Maria Valeria Jimenez; Ruiz Flores, Brenda; de Los Angeles Martinez Ferretiz, Maria; Woolf, Stephanny Vanestty; López, Israel; Sandoval-Jurado, Luis; Pat-Espadas, Fany Guadalupe; Cruz, Alan Alejandro Reyes; Delgado, Arsenio Torres

    2017-02-01

    Chronic lower limb ulcers constitute a public health problem, with important socioeconomic implications and high attention cost. This trial evaluates handcrafted vacuum-assisted therapy versus traditional treatment effectiveness for lower limbs ulcers. It was a prospective randomized clinical trial conducted over 144 patients with lower limbs ulcers. Patients were randomized into two groups of 72 patients: Experimental group were treated with debridement, cure and a handcrafted vacuum-assisted device that was changed every 72 h. Control group was treated with debridement and cure with soap every 24 h. Ulcers were evaluated every 72 h and on 10th day. The presence of systemic inflammatory response, pain, granulation tissue and viability for discharge was registered and analyzed . After exclusion of 18 patients, 126 were included, 65.1% were men with an average of 58 years. Sole region ulcer by diabetic foot was the more frequent in both groups (73%). Leukocytes count, systemic inflammatory response and pain were significantly lower in experimental group (p ulcers. This system would benefit patients favoring earlier infection control, faster granulation tissue appearance and earlier discharge. Clinical trials registered in https://www.clinicaltrials.gov/ Number NCT02512159.

  13. Devices for hearing loss

    Science.gov (United States)

    ... the sounds you want to hear. Assistive listening devices bring certain sounds directly to your ears. This can ... a small room or on a stage. Other devices can bring the sound from your TV, radio, or music ...

  14. 34 CFR 300.105 - Assistive technology.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Assistive technology. 300.105 Section 300.105 Education... DISABILITIES State Eligibility Other Fape Requirements § 300.105 Assistive technology. (a) Each public agency must ensure that assistive technology devices or assistive technology services, or both, as those terms...

  15. Determination of death after circulatory arrest by intensive care physicians: A survey of current practice in the Netherlands.

    Science.gov (United States)

    Wind, Jentina; van Mook, Walther N K A; Dhanani, Sonny; van Heurn, Ernest W L

    2016-02-01

    Determination of death is an essential part of donation after circulatory death (DCD). We studied the current practices of determination of death after circulatory arrest by intensive care physicians in the Netherlands, the availability of guidelines, and the occurrence of the phenomenon of autoresuscitation. The Determination of Cardiac Death Practices in Intensive Care Survey was sent to all intensive care physicians. Fifty-five percent of 568 Dutch intensive care physicians responded. Most respondents learned death determination from clinical practice. The most commonly used tests for death determination were flat arterial line tracing, flat electrocardiogram (standard 3-lead electrocardiogram), and fixed and dilated pupils. Rarely used tests were absence pulse by echo Doppler, absent blood pressure by noninvasive monitoring, and unresponsiveness to painful stimulus. No diagnostic test or procedure was uniformly performed, but 80% of respondents perceived a need for standardization of death determination. Autoresuscitation was witnessed by 37%, after withdrawal of treatment or after unsuccessful resuscitation. Extensive variability in the practice of determining death after circulatory arrest exists, and a need for guidelines and standardization, especially if organ donation follows death, is reported. Autoresuscitation is reported; this observation requires attention in further prospective observational studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Arthroscopically Assisted Coracoclavicular Fixation Using a Single Flip Button Device Technique: What Are the Main Factors Affecting the Maintenance of Reduction?

    Directory of Open Access Journals (Sweden)

    Yong-Beom Lee

    2017-01-01

    Full Text Available Background. Among coracoclavicular (CC fixation techniques, the use of flip button device was demonstrated to have successful outcomes with the advantage of being able to accommodate an arthroscopic procedure. Purpose. This study was conducted to investigate the factors associated with loss of fixation after arthroscopically assisted CC fixation using a single flip button device for acromioclavicular (AC joint dislocations. Materials and Methods. We enrolled a total of 47 patients (35 men and 12 women. Plain radiography was performed at a mean of 24 months postoperatively to evaluate the final radiological outcome. The primary outcome measure was a long-term reduction of the AC joint for at least 24 months. Results. We found that 29 patients had a high quality reduction (61.7% and 18 patients had a low quality reduction (38.3% in initial postoperative CT findings. Our study showed that the duration (5 days from injury to treatment and the quality of initial postoperative reduction were significantly associated with the maintenance of reduction at final follow-up. Conclusion. Our study showed that maintaining stable reduction after arthroscopically assisted CC fixation using a single flip button device technique is difficult especially in patients who received delayed treatment or whose initial reduction quality was poor.

  17. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2015-12-01

    Full Text Available A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  18. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    Science.gov (United States)

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  19. Circulatory shear flow alters the viability and proliferation of circulating colon cancer cells

    Science.gov (United States)

    Fan, Rong; Emery, Travis; Zhang, Yongguo; Xia, Yuxuan; Sun, Jun; Wan, Jiandi

    2016-06-01

    During cancer metastasis, circulating tumor cells constantly experience hemodynamic shear stress in the circulation. Cellular responses to shear stress including cell viability and proliferation thus play critical roles in cancer metastasis. Here, we developed a microfluidic approach to establish a circulatory microenvironment and studied circulating human colon cancer HCT116 cells in response to a variety of magnitude of shear stress and circulating time. Our results showed that cell viability decreased with the increase of circulating time, but increased with the magnitude of wall shear stress. Proliferation of cells survived from circulation could be maintained when physiologically relevant wall shear stresses were applied. High wall shear stress (60.5 dyne/cm2), however, led to decreased cell proliferation at long circulating time (1 h). We further showed that the expression levels of β-catenin and c-myc, proliferation regulators, were significantly enhanced by increasing wall shear stress. The presented study provides a new insight to the roles of circulatory shear stress in cellular responses of circulating tumor cells in a physiologically relevant model, and thus will be of interest for the study of cancer cell mechanosensing and cancer metastasis.

  20. Multidrug Resistant Pseudomonas Mycotic Pseudoaneurysm following Cardiac Transplant Bridged by Ventricular Assistant Device

    Directory of Open Access Journals (Sweden)

    C. Aye

    2017-01-01

    Full Text Available Mycotic pseudoaneurysm of aorta following cardiac surgery is rare but is highly fatal if it is unrecognized and untreated. Here, we report a case of a 45-year-old male patient who presented with rapidly progressive multiple pseudoaneurysms of the ascending aorta infected with multidrug resistant (MDR Pseudomonas aeruginosa at 5 weeks after cardiac transplantation, on a background of prior bridging therapy with left ventricular assistant device (LVAD. The patient was successfully treated with the newer cephalosporin, Ceftolozane/Tazobactam, in combination with surgery. This is the first reported case of mycotic pseudoaneurysm infected with MDR Pseudomonas. This case also highlights the importance of high vigilance and timely multimodality treatment in the diagnosis and management of mycotic pseudoaneurysm following cardiac transplant, especially in patients who had LVAD.

  1. Circulatory shock in horses / Choque circulatório em equinos

    Directory of Open Access Journals (Sweden)

    José Monteira da Silva Filho

    2010-04-01

    Full Text Available Circulatory shock can be defined as an acute circulatory failure with an inadequate tissue delivery of oxygen and nutritive substrates to the tissues, resulting in generalised cellular hypoxia. Shock can be classified as cardiogenic, obstructive, hypovolaemic, or distributive. The pathophysiologic consequences of inadequate tissue perfusion are directly related to cell ischemia, inadequate O2 delivery, and the production of proinflammatory mediators. If abnormalities of tissue perfusion are allowed to persist, the function of vital organs will be impaired. The subsequent reperfusion will exacerbate organ dysfunction and, in severe cases, may culminate in multiple organ dysfunction syndrome. Early recognition of equine that are shocked and immediate provision of effective circulatory support is therefore essential. In all cases the objective is to restore oxygen delivery to the tissues while correcting the underlying cause. Delays in making the diagnosis and initiating treatment, as well as suboptimal resuscitation, contribute to the development of peripheral vascular failure and irreversible defects in oxygen use which can culminate in vital organ dysfunction.Choque circulatório pode ser definido como uma falha circulatória aguda com liberação inadequada de oxigênio e nutrientes aos tecidos, resultando em hipóxia celular. O choque pode ser classificado como cardiogênico, obstrutivo, hipovolêmico ou distributivo. As consequências fisiopatológicas da perfusão tecidual inadequada estão diretamente relacionadas à isquemia celular, liberação inadequada de O2 e produção de potentes mediadores inflamatórios. Caso as anormalidades de perfusão tecidual se perpetuem, a função de vários órgãos se torna inadequada. A consequente reperfusão poderá exacerbar a disfunção orgânica e, nos casos graves, culminar na síndrome da disfunção orgânica múltipla. O reconhecimento precoce de equinos em choque circulatório e o

  2. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Science.gov (United States)

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  3. Pancreas transplantation with grafts from donors deceased after circulatory death (DCD) : 5 years single center experience

    NARCIS (Netherlands)

    Kopp, Wouter H; Lam, Hwai-Ding; Schaapherder, Alexander F M; Huurman, Volkert A L; van der Boog, Paul; de Koning, Eelco; de Fijter, Johan W; Baranski, Andrzej; Braat, Andries E

    2017-01-01

    INTRODUCTION: Donation after circulatory death (DCD) pancreas transplantation has been shown to be an additional way to deal with donor organ shortages. The results of 5-year DCD pancreas transplantation are presented. METHODS: A retrospective, single center analysis (2011 - 2015) was performed to

  4. Structural and composition investigations at delayered locations of low k integrated circuit device by gas-assisted focused ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dandan, E-mail: dandan.wang@globalfoundries.com; Kee Tan, Pik; Yamin Huang, Maggie; Lam, Jeffrey; Mai, Zhihong [Technology Development Department, GLOBALFOUNDRIES Singapore Pte. Ltd., 60 Woodlands Industrial Park D, Street 2, Singapore 738406 (Singapore)

    2014-05-15

    The authors report a new delayering technique – gas-assisted focused ion beam (FIB) method and its effects on the top layer materials of integrated circuit (IC) device. It demonstrates a highly efficient failure analysis with investigations on the precise location. After removing the dielectric layers under the bombardment of an ion beam, the chemical composition of the top layer was altered with the reduced oxygen content. Further energy-dispersive x-ray spectroscopy and Fourier transform infrared analysis revealed that the oxygen reduction lead to appreciable silicon suboxide formation. Our findings with structural and composition alteration of dielectric layer after FIB delayering open up a new insight avenue for the failure analysis in IC devices.

  5. Impact of long term left ventricular assist device therapy on donor allocation in cardiac transplantation.

    Science.gov (United States)

    Uriel, Nir; Jorde, Ulrich P; Woo Pak, Sang; Jiang, Jeff; Clerkin, Kevin; Takayama, Hiroo; Naka, Yoshifumi; Schulze, P Christian; Mancini, Donna M

    2013-02-01

    Left Ventricular Assist Devices (LVAD) are increasingly used as a bridge to transplant (BTT) for patients with advanced congestive heart failure (CHF) and are assigned United Network for Organ Sharing (UNOS) high priority status (1B or 1A). The purpose of our study was asses the effect of organ allocation in the era of continuous flow pumps. A retrospective chart review was performed of all patients transplanted between 1/2001-1/2011 at Columbia University Medical Center. Seven hundred twenty six adult heart transplantations were performed. Two hundred seventy four BTT patients were implanted with LVAD; of which 227 patients were transplanted. Sixty three patients were transplanted as UNOS-1B, while 164 were transplanted as UNOS-1A (72%). Of these 164 patients, 65 were transplanted during their 30-day 1A period (43%) and 96 after upgrading to UNOS-1A for device complication (56%). For 452 non-device patients 139 (31%) were transplanted as UNOS-1A, 233 as UNOS-1B (52%), and 80 as UNOS-2 (17%). The percentage of patients bridged with LVAD increased from 19% in 2001 to 64% in 2010 while the number transplanted during their 30 day 1A grace period declined from 57% in 2005 to 16% in 2011; i.e. 84% of BTT patients in 2011 needed more than 30 days 1A time to be transplanted. Most LVAD patients are now transplanted while suffering device complication. There was no difference in post transplant survival between LVAD patients transplanted as UNOS 1B, 1A grace period or for a device complication As wait time for cardiac transplantation increased the percentage of patients being bridged to transplant with an LVAD has increased with the majority of them transplanted in the setting of device complication. Copyright © 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  6. Successful Implantation of a Left Ventricular Assist Device After Treatment With the Paracor HeartNet.

    Science.gov (United States)

    Schweiger, Martin; Stepanenko, Alexander; Potapov, Evgenji; Drews, Thorsten; Hetzer, Roland; Krabatsch, Thomas

    2010-01-01

    The Paracor HeartNet, a ventricular constraint device for the treatment of heart failure (HF), is implanted through a left lateral thoracotomy. It envelopes the heart like a mesh "bag." This method of application raises the question of whether adhesions with the pericardium allow the safe implantation of a left ventricular assist device (LVAD) if HF worsens. A male patient who had undergone implantation of the Paracor HeartNet 42 months earlier presented with advanced HF for cardiac transplantation. The patient's condition deteriorated, and because no suitable organ for transplantation was available, implantation of an LVAD became necessary. Surgery was performed via a median sternotomy without complications. No severe adhesions were found. This is the first report on "how to do" LVAD implantation after Paracor HeartNet implantation with images and information about cutting the constraint. Because the Paracor HeartNet is "wrapped" around the heart, concerns persist that severe adhesions with the pericardium might occur. In this case, LVAD implantation after therapy with the Paracor HeartNet was without complications, and the expected massive adhesions were absent.

  7. Practical approaches to commencing device-assisted therapies for Parkinson disease in Australia.

    Science.gov (United States)

    Williams, David R; Evans, Andrew H; Fung, Victor S C; Hayes, Michael; Iansek, Robert; Kimber, Thomas; O'Sullivan, John D; Sue, Carolyn M

    2017-10-01

    In Australia 1% of individuals aged over 50 years have Parkinson disease (PD). Guidance for commencing device-assisted therapies (DAT) for PD in Australia was developed based on a review of European recommendations and their relevance to the local clinical setting. An online survey and teleconference discussions were held by a group of eight local movement disorder experts to develop consensus. Referral to a movement disorder specialist and consideration of DAT is appropriate when motor fluctuations cause disability or reduced quality of life, response to treatment is inconsistent or motor fluctuations and dyskinesias require frequent treatment adjustment without apparent benefit and levodopa is required four or more times daily. Three types of DAT are available in Australia for patients with PD: continuous subcutaneous apomorphine; continuous levodopa-carbidopa intestinal gel infusion; and deep brain stimulation. All improve consistency of motor response. The most important aspects when considering which DAT to use are the preferences of the patient and their carers, patient comorbidities, age, cognitive function and neuropsychiatric status. Patients and their families need to be provided with treatment options that are suitable to them, with adequate explanations regarding the recommendations and comparison of potential device-related complications. DAT are best managed, where possible, in a specialist centre with experience in all three types of therapy. Proactive and early management of symptoms during disease progression is essential to maintain optimally motor responses and quality of life in patients with PD. © 2017 Royal Australasian College of Physicians.

  8. Fabrication of three-dimensional scaffolds using precision extrusion deposition with an assisted cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Hamid, Q; Snyder, J; Wang, C; Guceri, S; Sun, W [Department of Mechanical Engineering and Mechanics, Drexel University, Philadelphia, PA (United States); Timmer, M; Hammer, J, E-mail: sunwei@drexel.edu [Advanced Technologies and Regenerative Medicine, Somerville, NJ (United States)

    2011-09-15

    In the field of biofabrication, tissue engineering and regenerative medicine, there are many methodologies to fabricate a building block (scaffold) which is unique to the target tissue or organ that facilitates cell growth, attachment, proliferation and/or differentiation. Currently, there are many techniques that fabricate three-dimensional scaffolds; however, there are advantages, limitations and specific tissue focuses of each fabrication technique. The focus of this initiative is to utilize an existing technique and expand the library of biomaterials which can be utilized to fabricate three-dimensional scaffolds rather than focusing on a new fabrication technique. An expanded library of biomaterials will enable the precision extrusion deposition (PED) device to construct three-dimensional scaffolds with enhanced biological, chemical and mechanical cues that will benefit tissue generation. Computer-aided motion and extrusion drive the PED to precisely fabricate micro-scaled scaffolds with biologically inspired, porosity, interconnectivity and internal and external architectures. The high printing resolution, precision and controllability of the PED allow for closer mimicry of tissues and organs. The PED expands its library of biopolymers by introducing an assisting cooling (AC) device which increases the working extrusion temperature from 120 to 250 deg. C. This paper investigates the PED with the integrated AC's capabilities to fabricate three-dimensional scaffolds that support cell growth, attachment and proliferation. Studies carried out in this paper utilized a biopolymer whose melting point is established to be 200 deg. C. This polymer was selected to illustrate the newly developed device's ability to fabricate three-dimensional scaffolds from a new library of biopolymers. Three-dimensional scaffolds fabricated with the integrated AC device should illustrate structural integrity and ability to support cell attachment and proliferation.

  9. Assistive Technology: Use and Service Delivery

    Directory of Open Access Journals (Sweden)

    Roya Ghasemzadeh

    2010-04-01

    Full Text Available As individuals with long-term disabilities and other older adults face declines in health and function, there is a greater need for assistive technology (AT or assistive devices and environmental interventions (EI to help them maintain their independence and community participation. These aids can help older adults and individuals with disabilities function in work, home, recreational, and other community settings as they encounter age related or disability related changes. Assistive Technology refers to products, devices or equipment that are used to maintain, increase or improve the functional capabilities of people with disabilities. A thorough assessment of the individual’s preferences and needs must be conducted before an assistive device is obtained. If one type of device is inadequate to meet an individual’s needs, it should not be assumed that there are no viable alternatives. Individuals’ use of AT and the type of technology used may change over time or as they age. Low-tech aids, such as canes or walkers, or high-tech aids, such as manual or power wheelchairs or scooters, are used to help individuals achieve mobility. Assistive Technologies to aid in communication currently range from low-tech devices such as books to high-tech, augmentative communication devices, which are computers. Computer technology can help individuals become more independent and can enhance their ability to overcome a wide range of limitations. Accessibility can involve more than architectural structure. AT for use in the environment can also increase individuals’ ability to function within their environment. Advancements in AT will occur in the technology itself, the services associated with the technology, and in the government policies and programs relative to AT. There will more widespread use of universal design, with less special-purpose AT required.

  10. Dispositivos de tecnología de asistencia para alimentación = Devices of assistive technology for feeding

    Directory of Open Access Journals (Sweden)

    Losada Gómez, A

    2007-02-01

    Full Text Available RESUMENEste artículo presenta los principales dispositivos de tecnología de asistencia que existen en Bogotá para facilitar el desempeño de la actividad de alimentación en personas que presentan algún tipo de discapacidad que limite esta ejecución, para ello, fue necesario realizar un estudio descriptivo donde se aplicó un instrumento tipo encuesta a personas que comercializan los mismos. Los principales resultados determinan que existen diferentes dispositivos para la función motora (mantener la postura sedente, facilitar agarres, facilitar patrón mano-boca y los patrones bucales (succión, deglución, masticación y digestión que se requieren en la alimentación. Como conclusión se determinó que actualmente en Colombia, los dispositivos de tecnología de asistencia para la alimentación son de baja tecnología y que existe fácil acceso a los mismos, pero se requiere realizar mayor difusión, también se encontró que no existen dispositivos que puedan facilitar esta actividad a personas que presenten parálisis en miembros superiores y que son mínimos los que presentan aplicación de tecnología de puntaABSTRACTThis article presents the principal devices of assistive technology that exist in Bogotá to facilitate the development of the activity of feeding in people that present some type of disability that limits this execution. Therefore, it was necessary to develop a descriptive study that included an instrument kind of inquiry to people that commercialize this devices. The principal results determine that there are different devices for the motor function (keep the sedentary posture, facilitate grips, facilitate hand-mouth patron and the buccal patrons (sucking, swallowing, chewing and digestion that are required in the feeding. As a conclusion it was determined that at present in Colombia, the devices of assistive technology for feeding have a low level of technology and there is an easy access to them, but is required to

  11. Low-frequency dynamics of autonomic regulation of circulatory system in healthy subjects

    Science.gov (United States)

    Skazkina, V. V.; Borovkova, E. I.; Galushko, T. A.; Khorev, V. S.; Kiselev, A. R.

    2018-04-01

    The paper is devoted to the analysis of dynamic of interactions between signals of autonomic circulatory regulation. We investigated two-hour experimental records of 30 healthy people. Phase synchronization was studied using the signals of the electrocardiogram and the photoplethysmogram of vessels. We found the presence of long synchronous intervals in some subjects. For analysis of the dynamic we calculated autocorrelation functions. The analysis made it possible to reveal indirect signs of the influence of the humoral regulation system.

  12. Antithrombin III is associated with acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support.

    Science.gov (United States)

    Hoefer, Judith; Ulmer, Hanno; Kilo, Juliane; Margreiter, Raimund; Grimm, Michael; Mair, Peter; Ruttmann, Elfriede

    2017-06-01

    There are few data on the role of liver dysfunction in patients with end-stage heart failure supported by mechanical circulatory support. The aim of our study was to investigate predictors for acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support. A consecutive 164 patients with heart failure with New York Heart Association class IV undergoing mechanical circulatory support were investigated for acute liver failure using the King's College criteria. Clinical characteristics of heart failure together with hemodynamic and laboratory values were analyzed by logistic regression. A total of 45 patients (27.4%) with heart failure developed subsequent acute liver failure with a hospital mortality of 88.9%. Duration of heart failure, cause, cardiopulmonary resuscitation, use of vasopressors, central venous pressure, pulmonary capillary wedge pressure, pulmonary pulsatility index, cardiac index, and transaminases were not significantly associated with acute liver failure. Repeated decompensation, atrial fibrillation (P failure in univariate analysis only. In multivariable analysis, decreased antithrombin III was the strongest single measurement indicating acute liver failure (relative risk per %, 0.84; 95% confidence interval, 0.77-0.93; P = .001) and remained an independent predictor when adjustment for the Model for End-Stage Liver Disease score was performed (relative risk per %, 0.89; 95% confidence interval, 0.80-0.99; P = .031). Antithrombin III less than 59.5% was identified as a cutoff value to predict acute liver failure with a corresponding sensitivity of 81% and specificity of 87%. In addition to the Model for End-Stage Liver Disease score, decreased antithrombin III activity tends to be superior in predicting acute liver failure compared with traditionally thought predictors. Antithrombin III measurement may help to identify patients more precisely who are developing acute liver failure during mechanical

  13. Ethical framework of assistive devices: review and reflection

    OpenAIRE

    Mansouri, Nazanin; Goher, Khaled; Hosseini, Seyed Ebrahim

    2017-01-01

    The population of ageing is growing significantly over the world, and there is an emerging demand for better healthcare services and more care centres. Innovations of Information and Communication Technology has resulted in development of various types of assistive robots to fulfil elderly’s needs and independency, whilst carrying out daily routine tasks. This makes it vital to have a clear understanding of elderly’s needs and expectations from assistive robots. This paper addresses current e...

  14. SdrF, a Staphylococcus epidermidis surface protein, contributes to the initiation of ventricular assist device driveline-related infections.

    Directory of Open Access Journals (Sweden)

    Carlos Arrecubieta

    2009-05-01

    Full Text Available Staphylococcus epidermidis remains the predominant pathogen in prosthetic-device infections. Ventricular assist devices, a recently developed form of therapy for end-stage congestive heart failure, have had considerable success. However, infections, most often caused by Staphylococcus epidermidis, have limited their long-term use. The transcutaneous driveline entry site acts as a potential portal of entry for bacteria, allowing development of either localized or systemic infections. A novel in vitro binding assay using explanted drivelines obtained from patients undergoing transplantation and a heterologous lactococcal system of surface protein expression were used to identify S. epidermidis surface components involved in the pathogenesis of driveline infections. Of the four components tested, SdrF, SdrG, PIA, and GehD, SdrF was identified as the primary ligand. SdrF adherence was mediated via its B domain attaching to host collagen deposited on the surface of the driveline. Antibodies directed against SdrF reduced adherence of S. epidermidis to the drivelines. SdrF was also found to adhere with high affinity to Dacron, the hydrophobic polymeric outer surface of drivelines. Solid phase binding assays showed that SdrF was also able to adhere to other hydrophobic artificial materials such as polystyrene. A murine model of infection was developed and used to test the role of SdrF during in vivo driveline infection. SdrF alone was able to mediate bacterial adherence to implanted drivelines. Anti-SdrF antibodies reduced S. epidermidis colonization of implanted drivelines. SdrF appears to play a key role in the initiation of ventricular assist device driveline infections caused by S. epidermidis. This pluripotential adherence capacity provides a potential pathway to infection with SdrF-positive commensal staphylococci first adhering to the external Dacron-coated driveline at the transcutaneous entry site, then spreading along the collagen

  15. Provision of assistive technology devices among people with ALS in Germany: a platform-case management approach.

    Science.gov (United States)

    Funke, Andreas; Spittel, Susanne; Grehl, Torsten; Grosskreutz, Julian; Kettemann, Dagmar; Petri, Susanne; Weyen, Ute; Weydt, Patrick; Dorst, Johannes; Ludolph, Albert C; Baum, Petra; Oberstadt, Moritz; Jordan, Berit; Hermann, Andreas; Wolf, Joachim; Boentert, Matthias; Walter, Bertram; Gajewski, Nadine; Maier, André; Münch, Christoph; Meyer, Thomas

    2018-01-30

    The procurement of assistive technology devices (ATD) is an essential component of managed care in ALS. The objective was to analyze the standards of care for ATD and to identify challenges in the provision process. A cohort study design was used. We investigated the provision of 11,364 ATD in 1494 patients with ALS at 12 ALS centers in Germany over four years. Participants were patients that entered a case management program for ATD including systematic assessment of ATD on a digital management platform. Wheelchairs (requested in 65% of patients), orthoses (52%), bathroom adaptations (49%), and communication devices (46%) were the most needed ATD. There was a wide range in the number of indicated ATD per patient: 1 to 4 ATD per patient in 45% of patients, 5 to 20 ATD in 48%, and >20 ATD in 7% of patients. Seventy percent of all requested ATD were effectively delivered. However, an alarming failure rate during procurement was found in ATD that are crucial for ALS patients such as powered wheelchairs (52%), communication devices (39%), or orthoses (21%). Leading causes for not providing ATD were the refusal by health insurances, the decision by patients, and the death of the patient before delivery of the device. The need for ATD was highly prevalent among ALS patients. Failed or protracted provision posed substantial barriers to ATD procurement. Targeted national strategies and the incorporation of ATD indication criteria in international ALS treatment guidelines are urgently needed to overcome these barriers.

  16. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  17. Exercise physiology in chronic mechanical circulatory support patients: vascular function and beyond.

    Science.gov (United States)

    Hayward, Christopher S; Fresiello, Libera; Meyns, Bart

    2016-05-01

    The majority of patients currently implanted with left ventricular assist devices have the expectation of support for more than 2 years. As a result, survival alone is no longer a sufficient distinctive for this technology, and there have been many studies within the last few years examining functional capacity and exercise outcomes. Despite strong evidence for functional class improvements and increases in simple measures of walking distance, there remains incomplete normalization of exercise capacity, even in the presence of markedly improved resting hemodynamics. Reasons for this remain unclear. Despite current pumps being run at a fixed speed, it is widely recognized that pump outputs significantly increase with exercise. The mechanism of this increase involves the interaction between preload, afterload, and the intrinsic pump function curves. The role of the residual heart function is also important in determining total cardiac output, as well as whether the aortic valve opens with exercise. Interactions with the vasculature, with skeletal muscle blood flow and the state of the autonomic nervous system are also likely to be important contributors to exercise performance. Further studies examining optimization of pump function with active pump speed modulation and options for optimization of the overall patient condition are likely to be needed to allow left ventricular assist devices to be used with the hope of full functional physiological recovery.

  18. 21 CFR 884.6170 - Assisted reproduction water and water purification systems.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction water and water purification... Devices § 884.6170 Assisted reproduction water and water purification systems. (a) Identification. Assisted reproduction water purification systems are devices specifically intended to generate high quality...

  19. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  20. Experiences Providing Medical Assistance during the Sewol Ferry Disaster Using Traditional Korean Medicine.

    Science.gov (United States)

    Kim, Kyeong Han; Jang, Soobin; Lee, Ju Ah; Jang, Bo-Hyoung; Go, Ho-Yeon; Park, Sunju; Jo, Hee-Guen; Lee, Myeong Soo; Ko, Seong-Gyu

    2017-01-01

    This study aimed to investigate medical records using traditional Korean medicine (TKM) in Sewol Ferry disaster in 2014 and further explore the possible role of traditional medicine in disaster situation. After Sewol Ferry accident, 3 on-site tents for TKM assistance by the Association of Korean Medicine (AKOM) in Jindo area were installed. The AKOM mobilized volunteer TKM doctors and assistants and dispatched each on-site tent in three shifts within 24 hours. Anyone could use on-site tent without restriction and TKM treatments including herb medicine were administered individually. The total of 1,860 patients were treated during the periods except for medical assistance on the barge. Most patients were diagnosed in musculoskeletal diseases (66.4%) and respiratory diseases (7.4%) and circulatory diseases (8.4%) followed. The most frequently used herbal medicines were Shuanghe decoction (80 days), Su He Xiang Wan (288 pills), and Wuji powder (73 days). TKM in medical assistance can be helpful to rescue worker or group life people in open shelter when national disasters occur. Therefore, it is important to construct a rapid respond system using TKM resources based on experience.

  1. Experiences Providing Medical Assistance during the Sewol Ferry Disaster Using Traditional Korean Medicine

    Directory of Open Access Journals (Sweden)

    Kyeong Han Kim

    2017-01-01

    Full Text Available Background. This study aimed to investigate medical records using traditional Korean medicine (TKM in Sewol Ferry disaster in 2014 and further explore the possible role of traditional medicine in disaster situation. Methods. After Sewol Ferry accident, 3 on-site tents for TKM assistance by the Association of Korean Medicine (AKOM in Jindo area were installed. The AKOM mobilized volunteer TKM doctors and assistants and dispatched each on-site tent in three shifts within 24 hours. Anyone could use on-site tent without restriction and TKM treatments including herb medicine were administered individually. Results. The total of 1,860 patients were treated during the periods except for medical assistance on the barge. Most patients were diagnosed in musculoskeletal diseases (66.4% and respiratory diseases (7.4% and circulatory diseases (8.4% followed. The most frequently used herbal medicines were Shuanghe decoction (80 days, Su He Xiang Wan (288 pills, and Wuji powder (73 days. Conclusions. TKM in medical assistance can be helpful to rescue worker or group life people in open shelter when national disasters occur. Therefore, it is important to construct a rapid respond system using TKM resources based on experience.

  2. Two new dynamic devices / orthoses for training / assisting / rehabilitation of hand functionality in patients with stroke as a result of clinical experience

    Directory of Open Access Journals (Sweden)

    Catalin Moghioroiu

    2016-12-01

    Full Text Available Introduction - Observing stroke patients with hemiplegia we can easily identify one of the problems they face –inability to use affected upper limb. On a closer analysis we can see that this incapacity is determined, at many of them, by the incapacity to open the hand and grasp. They follow therapies for months and the results are often mediocre therefore respectively upper limb is neglected and forgotten and its activities are taken up by the healthy upper limb. These observations have prompted the search for other type of solutions to help / assist them and facilitate participation. In this way were created twodynamic devices/orthotics that assists finger extension, facilitates grasping and increase, at least in theory, the possibilities of participation. Objective - The main purpose of this study is to test the effectiveness of using these devices on short and medium term. Material and method - For this study we will select 60 patients with single stroke. Patients will be randomized into two groups. Patients in the control group will receive a physical therapy session per day for 10 days. Patients in the experimental group will receive in addition a functional workout (20-30 minutes of handling small objects and few simple functional gestures of the "activities of daily living" using one of the two devices –the one that will allow the patient to best accomplish the given tasks. We will perform an initial assessment, one final and one to three months. The initiation of this study will be made after obtaining the opinion of the ethics committee, and the inclusion of patients will occur only after obtaining informed consent. Conclusions - Creation of two dynamic devices/orthotics witch assist finger extension and facilitate prehension opened the possibility of carrying out a clinical trial to test the effectiveness of their use. To what extent that this will happen remains to be seen.

  3. Identification of non-HLA antibodies in ventricular assist device recipients

    Directory of Open Access Journals (Sweden)

    Sandy von Salisch

    2013-11-01

    Full Text Available Aims Recipients of ventricular assist devices (VADR have a higher incidence to develop antibodies (Abs against human leukocyte antigens (HLA. Non-HLA antibodies like major histocompatibility complex class I-related chain A (MICA and autoantibodies against angiotensin type 1 receptor (AT1R and endothelin receptor A (ETAR are also implicated in the pathogenesis of acute rejection and allograft vasculopathy. We monitored non-HLA- and HLA-Abs in VADR up to one year after implantation. Materials and methods Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Results Sera of 56 VADR (54.1±12.8 years old, 50 men were analyzed for Abs against HLA-, MICA-, AT1R- and ETAR several times over one year after implantation using ELISA and Luminex xMAP technology. Blood transfusions, gender and age were reviewed. Conclusion Beside HLA- and MICA-Abs, VADR showed high titres of Abs against AT1R or ETAR, which underlines the necessity for monitoring non-HLA antibodies in VADR prior heart transplantation.

  4. Risk Stratification of Patients With Current Generation Continuous-Flow Left Ventricular Assist Devices Being Bridged to Heart Transplantation.

    Science.gov (United States)

    Guha, Ashrith; Nguyen, Duc; Cruz-Solbes, Ana S; Amione-Guerra, Javier; Schutt, Robert C; Bhimaraj, Arvind; Trachtenberg, Barry H; Park, Myung H; Graviss, Edward A; Gaber, Osama; Suarez, Erik; Montane, Eva; Torre-Amione, Guillermo; Estep, Jerry D

    Patients bridged to transplant (BTT) with continuous-flow left ventricular assist devices (CF-LVADs) have increased in the past decade. Decision support tools for these patients are limited. We developed a risk score to estimate prognosis and guide decision-making. We included heart transplant recipients bridged with CF-LVADs from the United Network for Organ Sharing (UNOS) database and divided them into development (2,522 patients) and validation cohorts (1,681 patients). Univariate and multivariate Cox proportional hazards models were performed. Variables that independently predicted outcomes (age, African American race, recipient body mass index [BMI], intravenous [IV] antibiotic use, pretransplant dialysis, and total bilirubin) were assigned weight using linear transformation, and risk scores were derived. Patients were grouped by predicted posttransplant mortality: low risk (≤ 38 points), medium risk (38-41 points), and high risk (≥ 42 points). We performed Cox proportional hazards analysis on wait-listed CF-LVAD patients who were not transplanted. Score significantly discriminated survival among the groups in the development cohort (6.7, 12.9, 20.7; p = 0.001), validation cohort (6.4, 10.1, 13.6; p assist device (LVAD) BTT risk score that effectively identifies CF-LVAD patients who are at higher risk for worse outcomes after heart transplant. This score may help physicians weigh the risks of transplantation in patients with CF-LVAD.

  5. Spectral line intensity irreversibility in circulatory plasma magnetization processes

    Science.gov (United States)

    Qu, Z. Q.; Dun, G. T.

    2012-01-01

    Spectral line intensity variation is found to be irreversible in circulatory plasma magnetization process by experiments described in this paper, i.e., the curves illustrating spectral line photon fluxes irradiated from a light source immerged in a magnetic field by increasing the magnetic induction cannot be reproduced by decreasing the magnetic induction within the errors. There are two plasma magnetization patterns found. One shows that the intensities are greater at the same magnetic inductions during the magnetic induction decreasing process after the increasing, and the other gives the opposite effect. This reveals that the magneto-induced excitation and de-excitation process is irreversible like ferromagnetic magnetization. But the two irreversible processes are very different in many aspects stated in the text.

  6. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  7. Colloids Versus Albumin in Large Volume Paracentesis to Prevent Circulatory Dysfunction: Evidence-based Case Report.

    Science.gov (United States)

    Widjaja, Felix F; Khairan, Paramita; Kamelia, Telly; Hasan, Irsan

    2016-04-01

    Large volume paracentesis may cause paracentesis induced circulatory dysfunction (PICD). Albumin is recommended to prevent this abnormality. Meanwhile, the price of albumin is too expensive and there should be another alternative that may prevent PICD. This report aimed to compare albumin to colloids in preventing PICD. Search strategy was done using PubMed, Scopus, Proquest, dan Academic Health Complete from EBSCO with keywords of "ascites", "albumin", "colloid", "dextran", "hydroxyethyl starch", "gelatin", and "paracentesis induced circulatory dysfunction". Articles was limited to randomized clinical trial and meta-analysis with clinical question of "In hepatic cirrhotic patient undergone large volume paracentesis, whether colloids were similar to albumin to prevent PICD". We found one meta-analysis and four randomized clinical trials (RCT). A meta analysis showed that albumin was still superior of which odds ratio 0.34 (0.23-0.51). Three RCTs showed the same results and one RCT showed albumin was not superior than colloids. We conclude that colloids could not constitute albumin to prevent PICD, but colloids still have a role in patient who undergone paracentesis less than five liters.

  8. Fluoroscopy-Guided Resolution of Ingested Thrombus Leading to Functional Disturbance of a Continuous-Flow Left Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2012-01-01

    Full Text Available The third generation of left ventricular assist devices (LVADs has been shown to improve outcome and quality of life in patients suffering from acute and chronic heart failure. However, VAD-associated complications are still a challenge in the clinical practice. Here we report the resolution of a mobile thrombus formation in the proximity of the inflow cannula of a third generation of LVADs (HVAD Pump, HeartWare, Inc. in a patient with chronic heart failure 4 months after implantation.

  9. Arthroscopically assisted reduction of acute acromioclavicular joint dislocation using a single double-button device: Medium-term clinical and radiological outcomes.

    Science.gov (United States)

    Issa, S-P; Payan, C; Le Hanneur, M; Loriaut, P; Boyer, P

    2018-02-01

    Double-button devices for endoscopic management of acute acromioclavicular joint dislocation (ACJD) provide satisfactory short-term functional and radiological results. However, little exists in the literature regarding the long- and medium-term results of these implants, especially regarding the evolution of the acromioclavicular joint (ACJ). Satisfactory and steady long- and medium-term outcomes can be achieved in patients with acute ACJD undergoing endoscopically assisted ACJ repair using a single double-button device. A retrospective single-center study was conducted in patients with acute Rockwood III and IV ACJD treated endoscopically with a single double-button device from October 2008 to October 2010, allowing a minimum 5-year follow-up. Functional evaluation used Constant and Quick-DASH scores. Clinical evidence of dislocation recurrence was combined with bilateral Zanca views to assess coracoclavicular distance. Acromioclavicular osteoarthritis was evaluated on the Paxinos test and Zanca views. Nineteen of the 25 operated patients were seen at a mean 76.9±8.5 months' follow-up. Mean age was 34.4±8.3 years. Mean Constant and Quick-DASH scores were 96.2±5.1 and 0.9±1.6 points, respectively. Four patients had a recurrence of their initial dislocation, 3 of whom had positive Paxinos test, whereas the 15 patients without recurrence had a negative test (p=0.004). Five patients had radiological evidence of ACJ osteoarthritis: all 4 patients with recurrence and 1 without (p=0.001). Long- and medium-term radioclinical outcome of endoscopically assisted management of acute ACJD using a single double-button device seems to be satisfactory and steady over time. Recurrence of the initial dislocation appears to be related to onset of degenerative ACJ arthropathy. Therapeutic type IV-Retrospective case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Using Technology in Social Work Practice: The mDad (Mobile Device Assisted Dad Case Study

    Directory of Open Access Journals (Sweden)

    Shawna J. Lee

    2015-07-01

    Full Text Available Mobile technology presents an exciting opportunity for social workers to reach populations that are typically underserved by interventions and services. We present one application of technology that is particularly relevant to social work practice. The mDad (Mobile Device Assisted Dad app was developed to augment existing social work practices by providing a father-friendly tool to help new fathers learn about and engage with their infants and toddlers. We discuss the process of developing the app content and conducting usability testing of the mDad app. We conclude with a discussion of the lessons learned from the mDad project, and the challenges of implementation and dissemination of technology-based interventions in community contexts.

  11. OUTCOMES OF LIVER TRANSPLANTATION USING DONATIONS AFTER CIRCULATORY DEATH : A SINGLE-CENTER EXPERIENCE

    OpenAIRE

    MEURISSE, Nicolas; VANDEN BUSSCHE, S; JOCHMANS, I; FRANCOIS, J; DESSCHANS, B; LALEMAN, W; VAN DER MERWE, S; VAN STEENBERGEN, W; CASSIMAN, D; VERSLYPE, C; AERTS, R; NEVENS, F; PIRENNE, J; MONBALIU, D

    2012-01-01

    Introduction Orthotopic liver transplantation (OLT) (LTx) using donation after circulatory death (DCD) donors is increasingly performed, but still considered to risk of poorer outcomes compared with standard donations after brain death (DBD)-OLT. Therefore we reviewed our results of DCD-OLT. Patients and Methods Between 2003 and 2010, we performed 30 DCD-OLT (6% of all OLT). We retrospectively reviewed medical records of donors and recipients after DCD versus DBD-OLT to analyze bil...

  12. A pacemaker powered by an implantable biofuel cell operating under conditions mimicking the human blood circulatory system--battery not included.

    Science.gov (United States)

    Southcott, Mark; MacVittie, Kevin; Halámek, Jan; Halámková, Lenka; Jemison, William D; Lobel, Robert; Katz, Evgeny

    2013-05-07

    Biocatalytic electrodes made of buckypaper were modified with PQQ-dependent glucose dehydrogenase on the anode and with laccase on the cathode and were assembled in a flow biofuel cell filled with serum solution mimicking the human blood circulatory system. The biofuel cell generated an open circuitry voltage, Voc, of ca. 470 mV and a short circuitry current, Isc, of ca. 5 mA (a current density of 0.83 mA cm(-2)). The power generated by the implantable biofuel cell was used to activate a pacemaker connected to the cell via a charge pump and a DC-DC converter interface circuit to adjust the voltage produced by the biofuel cell to the value required by the pacemaker. The voltage-current dependencies were analyzed for the biofuel cell connected to an Ohmic load and to the electronic loads composed of the interface circuit, or the power converter, and the pacemaker to study their operation. The correct pacemaker operation was confirmed using a medical device - an implantable loop recorder. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions using a single biofuel cell. This first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.

  13. Assistive Technology for Individuals with Special Seeds

    Directory of Open Access Journals (Sweden)

    Adrian Lupasc

    2015-09-01

    Full Text Available Disabled people face barriers in performing their various activities, including teaching. By using assistive technologies for different activities, people with disabilities may be able to perform a wider range of tasks independently. Fortunately, it helps to reduce many of these barriers, but, unfortunately, disabled people (learning, autism or ADHD face a variety of barriers when they want to use software tools or hardware devices. In this regard, assistive technologies are available to help persons with different types of disabilities, from cognitive problems to physical impairment. Hardware devices and software tools (known as adaptive or assistive technologies have been developed to provide functional alternatives for all individuals with disabilities, depending on the type of disability. In addition, the use of assistive technologies to support them is an effective approach for many persons with disabilities, regardless of the type of disability. Additionally, individuals with disabilities often experience greater success when they are allowed to use their abilities to work around their disabilities (the challenges they imply. Moreover, mobile devices are useful for their ability to weave Internet access and social networking into the daily life. To the people with disabilities, these devices have the potential to unlock unprecedented new possibilities for communication or navigation. In this context, some actual assistive technology and approaches to use them are described in this paper.

  14. Exercise physiology, testing, and training in patients supported by a left ventricular assist device.

    Science.gov (United States)

    Loyaga-Rendon, Renzo Y; Plaisance, Eric P; Arena, Ross; Shah, Keyur

    2015-08-01

    The left ventricular assist device (LVAD) is an accepted treatment alternative for the management of end-stage heart failure. As we move toward implantation of LVADs in less severe cases of HF, scrutiny of functional capacity and quality of life becomes more important. Patients demonstrate improvements in exercise capacity after LVAD implantation, but the effect is less than predicted. Exercise training produces multiple beneficial effects in heart failure patients, which would be expected to improve quality of life. In this review, we describe factors that are thought to participate in the persistent exercise impairment in LVAD-supported patients, summarize current knowledge about the effect of exercise training in LVAD-supported patients, and suggest areas for future research. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  15. Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

    Directory of Open Access Journals (Sweden)

    Basavana G Goudra

    2013-01-01

    Full Text Available Aims and Objectives: Continuous flow left ventricular assist devices (LVAD have emerged as a reliable treatment option for heart failure. Because of bleeding secondary to anticoagulation, these patients present frequently for gastrointestinal (GI endoscopy. The presently available literature on perioperative management of these patients is extremely limited and is primarily based upon theoretical principles. Materials and Methods: Perioperative records of patients with LVAD undergoing (GI endoscopy between 2008 and 2012 were reviewed. Patient, device and procedure specific information was analyzed. Results: A total of 105 LVADs were implanted, and 68 procedures were performed in 39 patients. The most common indication was GI bleed (48/68, with yearly risk of 8.57% per patient. A total of 63 procedures were performed under deep sedation, with five procedures requiring general anesthesia. Intra-procedure hypotension was managed by fluids and (or vasopressors/inotropes (phenylephrine, ephedrine or milrinone guided by plethysmographic waveform, non-invasive blood pressure (NIBP and LVADs pulsatility index (for HeartMate II/flow pulsatility (for HeartWare. No patient required invasive monitoring and both NIBP and pulse oximeter could be reliably used for monitoring (and guided management in all patients due to the presence of native heart′s pulsatile output. Conclusion: In the presence of residual heart function, with optimal device settings, non-invasive hemodynamic monitoring can be reliably used in these patients while undergoing GI endoscopy under general anesthesia or monitored anesthesia care. Transient hypotensive episodes respond well to fluids/vasopressors without the need of increasing device speed that can be detrimental.

  16. A MOBILE-DEVICE-SUPPORTED PEER-ASSISTED LEARNING SYSTEM FOR COLLABORATIVE EARLY EFL READING

    Directory of Open Access Journals (Sweden)

    Yu-Ju Lan

    2007-02-01

    Full Text Available Collaborative learning methods which emphasize peer interaction have been widely applied to increase the intensity and effectiveness of EFL reading programs. However, simply grouping students heterogeneously and assigning them group goals does not guarantee that effective collaborative learning will ensue. The present research includes two studies. In Study One, the weaknesses of collaborative learning in a traditional EFL setting were observed. Then, in Study Two, a mobile-device-supported peer-assisted learning (MPAL system was developed for the purpose of addressing the identified weaknesses. Two classes of twenty-six third grade students participated in the present research to examine the unique contribution of MPAL to collaborative EFL reading activities. The collaborative behavior of elementary EFL learners was videotaped and analyzed. Detailed analysis of the videotaped behavior indicated that MPAL helped improve collaboration in elementary school level EFL learners and promotes their reading motivation.

  17. Burden of Circulatory System Diseases and Ignored Barriers ofKnowledge Translation

    Directory of Open Access Journals (Sweden)

    Hamed-Basir Ghafouri

    2012-10-01

    Full Text Available Circulatory system disease raise third highest disability-adjusted life years among Iranians and ischemic cardiac diseases are main causes for such burden. Despite available evidences on risk factors of the disease, no effective intervention was implemented to control and prevent the disease. This paper non-systematically reviews available literature on the problem, solutions, and barriers of implementation of knowledge translation in Iran. It seems that there are ignored factors such as cultural and motivational issues in knowledge translation interventions but there are hopes for implementation of started projects and preparation of students as next generation of knowledge transferors.

  18. The role of perfusion lung scanning and diffusion capacity for early diagnosis of micro circulatory disturbances in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Petrova, D.; Shoshlov, P.; Hadjikostova, H.

    2002-01-01

    The development of chronic obstructive pulmonary disease (COPD) and the frequent inflammatory exacerbations with development of respiratory failure lead to changes in the micro circulatory and an increased risk of lung thrombotic and thromboembolic complication. The aim of the study was to establish the possibility of the perfusion lung scanning and diffusion capacity for early diagnosis of pulmonary micro circulatory disturbances in COPD with mild and moderate respiratory failure. 59 COPD patients were investigated. The data presented significant segmental disorders. Only in 5 (8.47%) of them the perfusion lung scintigrams were normal. In 23 of the patients, single-breath diffusing capacity (DICO) and its two components: membranous component (Dm) and capillary blood component (Vc) were determined. DICO was lower especially Vc the mean sign of micro circulatory disorders. A relationship between the degree of hypoxaemia and the changes found in the perfusion scintigraphy was found. Changes in the pulmonary lung scanning and in the diffusion capacity in COPD with mild respiratory failure seem to be an early diagnostic test. The early anticoagulant and desaggregant prevention may decrease the risk of thrombotic complications in the development of the disease. (authors)

  19. Sensitivity Analysis of Median Lifetime on Radiation Risks Estimates for Cancer and Circulatory Disease amongst Never-Smokers

    Science.gov (United States)

    Chappell, Lori J.; Cucinotta, Francis A.

    2011-01-01

    Radiation risks are estimated in a competing risk formalism where age or time after exposure estimates of increased risks for cancer and circulatory diseases are folded with a probability to survive to a given age. The survival function, also called the life-table, changes with calendar year, gender, smoking status and other demographic variables. An outstanding problem in risk estimation is the method of risk transfer between exposed populations and a second population where risks are to be estimated. Approaches used to transfer risks are based on: 1) Multiplicative risk transfer models -proportional to background disease rates. 2) Additive risk transfer model -risks independent of background rates. In addition, a Mixture model is often considered where the multiplicative and additive transfer assumptions are given weighted contributions. We studied the influence of the survival probability on the risk of exposure induced cancer and circulatory disease morbidity and mortality in the Multiplicative transfer model and the Mixture model. Risks for never-smokers (NS) compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for NS, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity, esophagus, colon, a portion of the solid cancer remainder, and leukemia. Greater improvements in risk estimates for NS s are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

  20. Extracorporeal membrane oxygenation (ECMO) assisted cardiopulmonary resuscitation or uncontrolled donation after the circulatory determination of death following out-of-hospital refractory cardiac arrest-An ethical analysis of an unresolved clinical dilemma.

    Science.gov (United States)

    Dalle Ave, Anne L; Shaw, David M; Gardiner, Dale

    2016-11-01

    The availability of extracorporeal membrane oxygenation (ECMO) assisted cardiopulmonary resuscitation (E-CPR), for use in refractory out-of hospital cardiac arrest (OHCA), is increasing. In parallel, some countries have developed uncontrolled donation after circulatory determination of death (uDCDD) programs using ECMO to preserve organs for transplantation purposes. When facing a refractory OHCA, how does the medical team choose between initiating ECMO as part of an E-CPR protocol or ECMO as part of a uDCDD protocol? To answer these questions we conducted a literature review on E-CPR compared to uDCDD protocols using ECMO and analyzed the raised ethical issues. Our analysis reveals that the inclusion criteria in E-CPR and uDCDD protocols are similar. There may be a non-negligible risk of including patients in a uDCDD protocol, when the patient might have been saved by the use of E-CPR. In order to avoid the fatal error of letting a saveable patient die, safeguards are necessary. We recommend: (1) the development of internationally accepted termination of resuscitation guidelines that would have to be satisfied prior to inclusion of patients in any uDCDD protocol, (2) the choice regarding modalities of ongoing resuscitation during transfer should be focused on the primary priority of attempting to save the life of patients, (3) only centers of excellence in life-saving resuscitation should initiate or maintain uDCDD programs, (4) E-CPR should be clinically considered first before the initiation of any uDCDD protocol, and (5) there should be no discrimination in the availability of access to E-CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Non-Invasive Mapping of Intraventricular Flow Patterns in Patients Treated with Left Ventricular Assist Devices

    Science.gov (United States)

    Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.

    2017-11-01

    In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.

  2. The vexing problem of thrombosis in long-term mechanical circulatory support.

    Science.gov (United States)

    Mehra, Mandeep R; Stewart, Garrick C; Uber, Patricia A

    2014-01-01

    Durable left ventricular assist devices (LVADs) have not only enhanced longevity but also conferred sustained improvements in quality of life, symptom control, and functional capacity in patients with medically refractory advanced heart failure. Problems with device-related infection, bleeding, neurologic events, right-sided heart failure, and device malfunction have dominated the clinical care of patients living on mechanical support. Even as adoption of durable LVADs accelerated globally, we began to encounter a growing dilemma of pump malfunction caused by thrombosis. In early 2011, clinicians began to notice a spike in the incidence of pump thrombosis with the HeartMate II (Thoratec Corp, Pleasanton, CA) LVAD. By 2012, the problem of thrombosis in LVADs began to consume most of the scientific direction as centers and collaborative groups began to dissect this nascent phenomenon. In this perspective, we describe the magnitude and implications of pump thrombosis, discuss secular and management trends in this unique population, attempt to dissect the problem at its root, offer guidance on surveillance and therapeutic principles, and outline issues that deserve our immediate and collaborative attention. © 2014 International Society for Heart and Lung Transplantation Published by International Society for the Heart and Lung Transplantation All rights reserved.

  3. Performance Evaluation Methods for Assistive Robotic Technology

    Science.gov (United States)

    Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.

    Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.

  4. CIRCULATORY FAILURE DURING NON-INHALED FORMS OF CYANIDE INTOXICATION

    Science.gov (United States)

    Haouzi, Philippe; Tubbs, Nicole; Rannals, Matthew D.; Judenherc-Haouzi, Annick; Cabell, Larry A.; McDonough, Joe A.; Sonobe, Takashi

    2016-01-01

    Our objective was to determine how circulatory failure develops following systemic administration of potassium cyanide (KCN). We used a non-inhaled modality of intoxication, wherein the change in breathing pattern would not influence the diffusion of CN into the blood, akin to the effects of ingesting toxic levels of CN. In a group of 300–400 g rats, CN-induced coma (CN IP, 7 mg/kg) produced a central apnea within 2–3 minutes along with a potent and prolonged gasping pattern leading to auto-resuscitation in 38% of the animals. Motor deficits and neuronal necrosis were nevertheless observed in the surviving animals. To clarify the mechanisms leading to potential auto-resuscitation versus asystole, 12 urethane-anesthetized rats were then exposed to the lowest possible levels of CN exposure that would lead to breathing depression within 7–8 minutes; this dose averaged 0.375 mg/kg/min iv. At this level of intoxication, a cardiac depression developed several minutes only after the onset of the apnea, leading to cardiac asystole as PaO2 reached value around 15 Torr, unless breathing was maintained by mechanical ventilation or through spontaneous gasping. Higher levels of KCN exposure in 10 animals provoked a primary cardiac depression, which led to a rapid cardiac arrest by pulseless electrical activity despite the maintenance of PaO2 by mechanical ventilation. These effects were totally unrelated to the potassium contained in KCN. It is concluded that circulatory failure can develop as a direct consequence of CN induced apnea but in a narrow range of exposure. In this “low” range, maintaining pulmonary gas exchange after exposure, through mechanical ventilation (or spontaneous gasping) can reverse cardiac depression and restore spontaneous breathing. At higher level of intoxication, cardiac depression is to be treated as a specific and spontaneously irreversible consequence of CN exposure, leading to a pulseless electrical activity. PMID:27513083

  5. Laser-assisted simultaneous transfer and patterning of vertically aligned carbon nanotube arrays on polymer substrates for flexible devices.

    Science.gov (United States)

    In, Jung Bin; Lee, Daeho; Fornasiero, Francesco; Noy, Aleksandr; Grigoropoulos, Costas P

    2012-09-25

    We demonstrate a laser-assisted dry transfer technique for assembling patterns of vertically aligned carbon nanotube arrays on a flexible polymeric substrate. A laser beam is applied to the interface of a nanotube array and a polycarbonate sheet in contact with one another. The absorbed laser heat promotes nanotube adhesion to the polymer in the irradiated regions and enables selective pattern transfer. A combination of the thermal transfer mechanism with rapid direct writing capability of focused laser beam irradiation allows us to achieve simultaneous material transfer and direct micropatterning in a single processing step. Furthermore, we demonstrate that malleability of the nanotube arrays transferred onto a flexible substrate enables post-transfer tailoring of electric conductance by collapsing the aligned nanotubes in different directions. This work suggests that the laser-assisted transfer technique provides an efficient route to using vertically aligned nanotubes as conductive elements in flexible device applications.

  6. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  7. The Impact of Ionospheric and Geomagnetic Changes on Mortality from Diseases of the Circulatory System

    Czech Academy of Sciences Publication Activity Database

    Podolská, Kateřina

    2018-01-01

    Roč. 27, č. 2 (2018), s. 404-417 ISSN 1052-3057 Institutional support: RVO:68378289 Keywords : mortality * circulatory system diseases * solar indices * cluster analysis using time Subject RIV: DN - Health Impact of the Environment Quality OBOR OECD: Public and environmental health Impact factor: 1.517, year: 2016 http://www.strokejournal.org/article/S1052-3057(17)30488-3/fulltext

  8. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    Science.gov (United States)

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  9. The NHLBI REVIVE-IT study: Understanding its discontinuation in the context of current left ventricular assist device therapy.

    Science.gov (United States)

    Pagani, Francis D; Aaronson, Keith D; Kormos, Robert; Mann, Douglas L; Spino, Cathie; Jeffries, Neal; Taddei-Peters, Wendy C; Mancini, Donna M; McNamara, Dennis M; Grady, Kathleen L; Gorcsan, John; Petrucci, Ralph; Anderson, Allen S; Glick, Henry A; Acker, Michael A; Eduardo Rame, J; Goldstein, Daniel J; Pamboukian, Salpy V; Miller, Marissa A; Timothy Baldwin, J

    2016-11-01

    The National Institutes of Health National Heart, Lung, and Blood Institute convened a working group in March 2008 to discuss how therapies for heart failure (HF) might be best advanced using clinical trials involving left ventricular assist devices (LVAD). This group opined that the field was ready for a trial to assess the use of long-term ventricular assist device therapy in patients who are less ill than patients currently eligible for destination therapy, which resulted in the Randomized Evaluation of VAD InterVEntion before Inotropic Therapy (REVIVE-IT) pilot study. The specific objective of REVIVE-IT was to compare LVAD therapy with optimal medical management in patients with less advanced HF than current LVAD indications to determine if wider application of permanent LVAD use to less ill patients would be associated with improved survival, quality of life, or functional capacity. REVIVE-IT represented an extraordinary effort to provide data from a randomized clinical trial to inform clinicians, scientists, industry, and regulatory agencies about the efficacy and safety of LVAD therapy in a population with less advanced HF. Despite significant support from the medical community, industry, and governmental agencies, REVIVE-IT failed to accomplish its goal. The reasons for its failure are instructive, and the lessons learned from the REVIVE-IT experience are likely to be relevant to any future study of LVAD therapy in a population with less advanced HF. Copyright © 2016 International Society for Heart and Lung Transplantation. All rights reserved.

  10. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  11. Radio-frequency-assisted current startup in the Fusion Engineering Device

    International Nuclear Information System (INIS)

    Borowski, S.K.; Kammash, T.; Martin Peng, Y.K.

    1984-01-01

    Auxiliary radio-frequency (RF) heating of electrons before and during the current rise phase of a large tokamak, such as the Fusion Engineering Device (FED) (R 0 = 4.8 m, a = 1.3 m, sigma = 1.6, B(R 0 ) = 3.62 T), is examined as a means of reducing both the initiation loop voltage and resistive flux expenditure during startup. Prior to current initiation, 1 to 2 MW of electron cyclotron resonance heating power at about90 GHz is used to create a small volume of high conductivity plasma (T /sub e/ approx. = 100 eV, n /sub e/ approx. = 10 19 m -3 ) near the upper hybrid resonance (UHR) region. This plasma conditioning, referred to as preheating, permits a small radius (a 0 approx. = 0.2 to 0.4 m) current channel to be established with a relatively low initial loop voltage (less than or equal to 25 V as opposed to about 100 V without rf assist). During the subsequent plasma expansion and current rise phase, a combination of rf heating (up to 5 MW) and linear current ramping leads to a substantial savings in voltseconds by (a) minimizing the resistive flux consumption and (b) producing broad current density profiles. (With such broad profiles, the internal flux requirements are maintained at or near the flat profile limit.)

  12. Engineered embodiment: Comment on "The embodiment of assistive devices-from wheelchair to exoskeleton" by M. Pazzaglia and M. Molinari

    Science.gov (United States)

    Kannape, Oliver Alan; Lenggenhager, Bigna

    2016-03-01

    From brain-computer interfaces to wearable robotics and bionic prostheses - intelligent assistive devices have already become indispensable in the therapy of people living with reduced sensorimotor functioning of their physical body, be it due to spinal cord injury, amputation or brain lesions [1]. Rapid technological advances will continue to fuel this field for years to come. As Pazzaglia and Molinari [2] rightly point out, progress in this domain should not solely be driven by engineering prowess, but utilize the increasing psychological and neuroscientific understanding of cortical body-representations and their plasticity [3]. We argue that a core concept for such an integrated embodiment framework was introduced with the formalization of the forward model for sensorimotor control [4]. The application of engineering concepts to human movement control paved the way for rigorous computational and neuroscientific analysis. The forward model has successfully been adapted to investigate principles underlying aspects of bodily awareness such as the sense of agency in the comparator framework [5]. At the example of recent advances in lower limb prostheses, we propose a cross-disciplinary, integrated embodiment framework to investigate the sense of agency and the related sense of body ownership for such devices. The main onus now is on the engineers and cognitive scientists to embed such an approach into the design of assistive technology and its evaluation battery.

  13. Electronic and optical device applications of hollow cathode plasma assisted atomic layer deposition based GaN thin films

    International Nuclear Information System (INIS)

    Bolat, Sami; Tekcan, Burak; Ozgit-Akgun, Cagla; Biyikli, Necmi; Okyay, Ali Kemal

    2015-01-01

    Electronic and optoelectronic devices, namely, thin film transistors (TFTs) and metal–semiconductor–metal (MSM) photodetectors, based on GaN films grown by hollow cathode plasma-assisted atomic layer deposition (PA-ALD) are demonstrated. Resistivity of GaN thin films and metal-GaN contact resistance are investigated as a function of annealing temperature. Effect of the plasma gas and postmetallization annealing on the performances of the TFTs as well as the effect of the annealing on the performance of MSM photodetectors are studied. Dark current to voltage and responsivity behavior of MSM devices are investigated as well. TFTs with the N 2 /H 2 PA-ALD based GaN channels are observed to have improved stability and transfer characteristics with respect to NH 3 PA-ALD based transistors. Dark current of the MSM photodetectors is suppressed strongly after high-temperature annealing in N 2 :H 2 ambient

  14. Extracorporeal liver assist device to exchange albumin and remove endotoxin in acute liver failure: Results of a pivotal pre-clinical study.

    Science.gov (United States)

    Lee, Karla C L; Baker, Luisa A; Stanzani, Giacomo; Alibhai, Hatim; Chang, Yu Mei; Jimenez Palacios, Carolina; Leckie, Pamela J; Giordano, Paola; Priestnall, Simon L; Antoine, Daniel J; Jenkins, Rosalind E; Goldring, Christopher E; Park, B Kevin; Andreola, Fausto; Agarwal, Banwari; Mookerjee, Rajeshwar P; Davies, Nathan A; Jalan, Rajiv

    2015-09-01

    In acute liver failure, severity of liver injury and clinical progression of disease are in part consequent upon activation of the innate immune system. Endotoxaemia contributes to innate immune system activation and the detoxifying function of albumin, critical to recovery from liver injury, is irreversibly destroyed in acute liver failure. University College London-Liver Dialysis Device is a novel artificial extracorporeal liver assist device, which is used with albumin infusion, to achieve removal and replacement of dysfunctional albumin and reduction in endotoxaemia. We aimed to test the effect of this device on survival in a pig model of acetaminophen-induced acute liver failure. Pigs were randomised to three groups: Acetaminophen plus University College London-Liver Dialysis Device (n=9); Acetaminophen plus Control Device (n=7); and Control plus Control Device (n=4). Device treatment was initiated two h after onset of irreversible acute liver failure. The Liver Dialysis Device resulted in 67% reduced risk of death in acetaminophen-induced acute liver failure compared to Control Device (hazard ratio=0.33, p=0.0439). This was associated with 27% decrease in circulating irreversibly oxidised human non-mercaptalbumin-2 throughout treatment (p=0.046); 54% reduction in overall severity of endotoxaemia (p=0.024); delay in development of vasoplegia and acute lung injury; and delay in systemic activation of the TLR4 signalling pathway. Liver Dialysis Device-associated adverse clinical effects were not seen. The survival benefit and lack of adverse effects would support clinical trials of University College London-Liver Dialysis Device in acute liver failure patients. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  15. Advanced strategies for end-stage heart failure: combining regenerative approaches with LVAD, a new horizon?

    Directory of Open Access Journals (Sweden)

    Cheyenne eTseng

    2015-04-01

    Full Text Available Despite the improved treatment of cardiovascular diseases the population with end-stage heart failure is progressively growing. The scarcity of the gold standard therapy, heart transplantation, demands novel therapeutic approaches. For patients awaiting transplantation ventricular assist devices have been of great benefit on survival. To allow explantation of the assist device and obviate heart transplantation, sufficient and durable myocardial recovery is necessary. However, explant rates so far are low. Combining mechanical circulatory support with regenerative therapies such as cell(-based therapy and biomaterials might give rise to improved long-term results. Although synergistic effects are suggested with mechanical support and stem cell therapy, evidence in both preclinical and clinical setting is lacking. This review focuses on advanced and innovative strategies for the treatment of end-stage heart failure and furthermore appraises clinical experience with combined strategies.

  16. Assistive technology and passengers with special assistance needs in air transport: contributions to cabin design

    Directory of Open Access Journals (Sweden)

    Carina Campese

    2016-06-01

    Full Text Available Abstract There has been significant growth in air transport worldwide, as well as in Brazil. However, studies have emphasized that disabled, obese, and elderly passengers face difficulties when using this means of transport. Among these difficulties, issues related to passengers’ own assistive devices, including damage, loss, or the impossibility of using during the entire flight, stand out. Therefore, the present study aims to understand the trends in assistive technology focusing on cabin design. This research is based upon literature review, interviews with manufacturers and research centers, visits to specialized trade fairs, and patent search. The results revealed a great diversity of assistive products, its trends, and an increase in their use, which affect aircraft cabin design, especially in terms of space, access, and stowage of these devices.

  17. CT screening of vertebrarterial circulatory disorder

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru; Toyoda, Keiko; Moriyama, Hiroshi [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-09-01

    The frequency of MR angiography (MRA) used to diagnose vertebrobasiliar insufficiency appears high. Findings of abnormality by MRA show cases with maldescription of hemivertebral artery. In such cases, it is unclear whether these are due to anaplasia of the vertebral artery or to the existence of morbid constriction, thus requiring confirmation by a vertebral arteriography (VAG). We observe the vascular morphology of vertebral artery by Computed tomography (CT) scanning for screening circulatory disorders. In photography and CT scan reading, the region was severally photographed between foramen magnum and aortic arch by plain CT and contrast CT at a slice of 5 mm. The constrictive region of the vertebral artery was estimated by comparing plain and contrast CT. Subjects were 34 clinical cases of vascular maldescription in the vertebrobasilar artery, nearly no blood vessel description, or blood vessel winding or inclination. We determined the constrictive morbid state of the vertebral or subclavian artery and cervical vertebra deformity. In findings of maldescription by MRA, it was suggested that discrimination is feasible to a certain degree, whether the vertebral artery has a morbid constrictive region or due to anaplasia. Our results suggest that screening by CT scanning may be more efficient than that by MRA. (author)

  18. CT screening of vertebrarterial circulatory disorder

    International Nuclear Information System (INIS)

    Yoshida, Shigeru; Toyoda, Keiko; Moriyama, Hiroshi

    2001-01-01

    The frequency of MR angiography (MRA) used to diagnose vertebrobasiliar insufficiency appears high. Findings of abnormality by MRA show cases with maldescription of hemivertebral artery. In such cases, it is unclear whether these are due to anaplasia of the vertebral artery or to the existence of morbid constriction, thus requiring confirmation by a vertebral arteriography (VAG). We observe the vascular morphology of vertebral artery by Computed tomography (CT) scanning for screening circulatory disorders. In photography and CT scan reading, the region was severally photographed between foramen magnum and aortic arch by plain CT and contrast CT at a slice of 5 mm. The constrictive region of the vertebral artery was estimated by comparing plain and contrast CT. Subjects were 34 clinical cases of vascular maldescription in the vertebrobasilar artery, nearly no blood vessel description, or blood vessel winding or inclination. We determined the constrictive morbid state of the vertebral or subclavian artery and cervical vertebra deformity. In findings of maldescription by MRA, it was suggested that discrimination is feasible to a certain degree, whether the vertebral artery has a morbid constrictive region or due to anaplasia. Our results suggest that screening by CT scanning may be more efficient than that by MRA. (author)

  19. Assisting the older driver : intersection design and in-car devices to improve the safety of the older driver. Proefschrift Rijksuniversiteit Groningen RUG, Groningen.

    NARCIS (Netherlands)

    Davidse, R.J.

    2007-01-01

    In this thesis, the main focus was on assistive devices that may improve and prolong the safe mobility of older drivers. Older drivers form a group of road users that is getting more and more attention in road safety research and policy. An important reason for this growing interest is the increase

  20. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  1. Laser-Assisted Simultaneous Transfer and Patterning of Vertically Aligned Carbon Nanotube Arrays on Polymer Substrates for Flexible Devices

    KAUST Repository

    In, Jung Bin

    2012-09-25

    We demonstrate a laser-assisted dry transfer technique for assembling patterns of vertically aligned carbon nanotube arrays on a flexible polymeric substrate. A laser beam is applied to the interface of a nanotube array and a polycarbonate sheet in contact with one another. The absorbed laser heat promotes nanotube adhesion to the polymer in the irradiated regions and enables selective pattern transfer. A combination of the thermal transfer mechanism with rapid direct writing capability of focused laser beam irradiation allows us to achieve simultaneous material transfer and direct micropatterning in a single processing step. Furthermore, we demonstrate that malleability of the nanotube arrays transferred onto a flexible substrate enables post-transfer tailoring of electric conductance by collapsing the aligned nanotubes in different directions. This work suggests that the laser-assisted transfer technique provides an efficient route to using vertically aligned nanotubes as conductive elements in flexible device applications. © 2012 American Chemical Society.

  2. The influence of assistive technology devices on the performance of activities by visually impaired

    Directory of Open Access Journals (Sweden)

    Suzana Rabello

    2014-04-01

    Full Text Available Objective: To establish the influence of assistive technology devices (ATDs on the performance of activities by visually impaired schoolchildren in the resource room. Methods: A qualitative study that comprised observation and an educational intervention in the resource room. The study population comprised six visually impaired schoolchildren aged 12 to 14 years old. The participants were subjected to an eye examination, prescribed ATDs comprising optical and non-optical devices, and provided an orientation on the use of computers. The participants were assessed based on eye/object distance, font size, and time to read a computer screen and printed text. Results: The ophthalmological conditions included corneal opacity, retinochoroiditis, retinopathy of prematurity, aniridia, and congenital cataracts. Far visual acuity varied from 20/200 to 20/800 and near visual acuity from 0.8 to 6 M. Telescopes, spherical lenses, and support magnifying glasses were prescribed. Three out of five participants with low vision after intervention could decrease the font size on the screen computer, and most participants (83.3% reduced their reading time at the second observation session. Relative to the printed text, all the participants with low vision were able to read text written in smaller font sizes and reduced their reading time at the second observation session. Conclusion: Reading skills improved after the use of ATDs, which allowed the participants to perform their school tasks equally to their classmates.

  3. Exotendons for assistance of human locomotion

    Directory of Open Access Journals (Sweden)

    van den Bogert Antonie J

    2003-10-01

    Full Text Available Abstract Background Powered robotic exoskeletons for assistance of human locomotion are currently under development for military and medical applications. The energy requirements for such devices are excessive, and this has become a major obstacle for practical applications. Legged locomotion in many animals, however, is very energy efficient. We propose that poly-articular elastic mechanisms are a major contributor to the economy of locomotion in such specialized animals. Consequently, it should be possible to design unpowered assistive devices that make effective use of similar mechanisms. Methods A passive assistive technology is presented, based on long elastic cords attached to an exoskeleton and guided by pulleys placed at the joints. A general optimization procedure is described for finding the best geometrical arrangement of such "exotendons" for assisting a specific movement. Optimality is defined either as minimal residual joint moment or as minimal residual joint power. Four specific exotendon systems with increasing complexity are considered. Representative human gait data were used to optimize each of these four systems to achieve maximal assistance for normal walking. Results The most complex exotendon system, with twelve pulleys per limb, was able to reduce the joint moments required for normal walking by 71% and joint power by 74%. A simpler system, with only three pulleys per limb, could reduce joint moments by 46% and joint power by 47%. Conclusion It is concluded that unpowered passive elastic devices can substantially reduce the muscle forces and the metabolic energy needed for walking, without requiring a change in movement. When optimally designed, such devices may allow independent locomotion in patients with large deficits in muscle function.

  4. Occlusive ascending aorta and arch atheroma treated with deep hypothermic circulatory arrest and thromboendarterectomy.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2013-12-01

    We describe an uncommon presentation of severely advanced aortic atherosclerosis in a 48-year old man with a history of hypertension and heavy smoking. Initial presentation with upper limb ischaemia led to the diagnosis of an aortic arch atheroma occluding 90% of the aortic lumen, managed with deep hypothermic circulatory arrest and aortic thromboendarterectomy. To our knowledge, this is the first reported case of atherosclerotic plaque resulting in aortic occlusion and requiring emergent operative intervention.

  5. Ethical framework of assistive devices: review and reflection.

    Science.gov (United States)

    Mansouri, Nazanin; Goher, Khaled; Hosseini, Seyed Ebrahim

    2017-01-01

    The population of ageing is growing significantly over the world, and there is an emerging demand for better healthcare services and more care centres. Innovations of Information and Communication Technology has resulted in development of various types of assistive robots to fulfil elderly's needs and independency, whilst carrying out daily routine tasks. This makes it vital to have a clear understanding of elderly's needs and expectations from assistive robots. This paper addresses current ethical issues to understand elderly's prime needs. Also, we consider other general ethics with the purpose of applying these theories to form a proper ethics framework. In the ethics framework, the ethical concerns of senior citizens will be prioritized to satisfy elderly's needs and also to diminish related expenses to healthcare services.

  6. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  7. A walker used as a lifting device.

    Science.gov (United States)

    Glimskär, Bo; Hjalmarson, Jenny; Lundberg, Stefan; Larsson, Tore

    2014-05-01

    To develop assistive technology that would help an older person to arise from a kneeling position to a standing one. Developing a prototype, based on an inclusive design and then testing the prototype to verify the approach. The prototype was subsequently tested by a panel of 20 elderly users. These tests were observed and filmed. Participants' experiences of being lifted with the elevation seat were registered with the VIDAR ergonomic assessment system. None of the 20 participants used a walker at that time. In response to a question of whether, assuming they might have to use a walker in the future, they thought that a walker with an elevating seat would be helpful, 18 said that it would. Two of the participants did not believe that they would ever have to use a walker. A simple assistive technology such as a walker equipped with an elevating seat would in many of these cases simplify matters and reduce the distress of people who fall often. In addition, such a device can allow people who fall often to live in their homes longer. For caregivers dealing frequently with people who fall, this assistive device can contribute to decreasing occupational injuries. Development of a lifting device that can help people raise themselves up entirely on their own, or with minimal assistance, would be a revolutionary step for the individual. Lifting devices in use today requires much more extensive assistance from home helpers or others and due to the risk of injuries it is a great value for the helpers that easy to use devices develops. A walker equipped with an elevating seat could even provide a potential for people to stay in their homes longer.

  8. 76 FR 15368 - Minimum Security Devices and Procedures

    Science.gov (United States)

    2011-03-21

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision Minimum Security Devices and Procedures... concerning the following information collection. Title of Proposal: Minimum Security Devices and Procedures... security devices and procedures to discourage robberies, burglaries, and larcenies, and to assist in the...

  9. Numerical Models of Human Circulatory System under Altered Gravity: Brain Circulation

    Science.gov (United States)

    Kim, Chang Sung; Kiris, Cetin; Kwak, Dochan; David, Tim

    2003-01-01

    A computational fluid dynamics (CFD) approach is presented to model the blood flow through the human circulatory system under altered gravity conditions. Models required for CFD simulation relevant to major hemodynamic issues are introduced such as non-Newtonian flow models governed by red blood cells, a model for arterial wall motion due to fluid-wall interactions, a vascular bed model for outflow boundary conditions, and a model for auto-regulation mechanism. The three-dimensional unsteady incompressible Navier-Stokes equations coupled with these models are solved iteratively using the pseudocompressibility method and dual time stepping. Moving wall boundary conditions from the first-order fluid-wall interaction model are used to study the influence of arterial wall distensibility on flow patterns and wall shear stresses during the heart pulse. A vascular bed modeling utilizing the analogy with electric circuits is coupled with an auto-regulation algorithm for multiple outflow boundaries. For the treatment of complex geometry, a chimera overset grid technique is adopted to obtain connectivity between arterial branches. For code validation, computed results are compared with experimental data for steady and unsteady non-Newtonian flows. Good agreement is obtained for both cases. In sin-type Gravity Benchmark Problems, gravity source terms are added to the Navier-Stokes equations to study the effect of gravitational variation on the human circulatory system. This computational approach is then applied to localized blood flows through a realistic carotid bifurcation and two Circle of Willis models, one using an idealized geometry and the other model using an anatomical data set. A three- dimensional anatomical Circle of Willis configuration is reconstructed from human-specific magnetic resonance images using an image segmentation method. The blood flow through these Circle of Willis models is simulated to provide means for studying gravitational effects on the brain

  10. Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock

    Science.gov (United States)

    Esenaliev, Rinat O.; Petrov, Irene Y.; Petrov, Yuriy; Kinsky, Michael; Prough, Donald S.

    2012-02-01

    Circulatory shock is lethal, if not promptly diagnosed and effectively treated. Typically, circulatory shock resuscitation is guided by blood pressure, heart rate, and mental status, which have poor predictive value. In patients, in whom early goaldirected therapy was applied using central venous oxygenation measurement, a substantial reduction of mortality was reported (from 46.5% to 30%). However, central venous catheterization is invasive, time-consuming and often results in complications. We proposed to use the optoacoustic technique for noninvasive, rapid assessment of central venous oxygenation. In our previous works we demonstrated that the optoacoustic technique can provide measurement of blood oxygenation in veins and arteries due to high contrast and high resolution. In this work we developed a novel optoacoustic system for noninvasive, automatic, real-time, and continuous measurement of central venous oxygenation. We performed pilot clinical tests of the system in human subjects with different oxygenation in the internal jugular vein and subclavian vein. A novel optoacoustic interface incorporating highly-sensitive optoacoustic probes and standard ultrasound imaging probes were developed and built for the study. Ultrasound imaging systems Vivid i and hand-held Vscan (GE Healthcare) as well as Site-Rite 5 (C.R. Bard) were used in the study. We developed a special algorithm for oxygenation monitoring with minimal influence of overlying tissue. The data demonstrate that the system provides precise measurement of venous oxygenation continuously and in real time. Both current value of the venous oxygenation and trend (in absolute values and for specified time intervals) are displayed in the system. The data indicate that: 1) the optoacoustic system developed by our group is capable of noninvasive measurement of blood oxygenation in specific veins; 2) clinical ultrasound imaging systems can facilitate optoacoustic probing of specific blood vessels; 3) the

  11. Ramp Study Hemodynamics, Functional Capacity, and Outcome in Heart Failure Patients with Continuous-Flow Left Ventricular Assist Devices

    DEFF Research Database (Denmark)

    Jung, Mette H; Gustafsson, Finn; Houston, Brian

    2016-01-01

    Ramp studies-measuring changes in cardiac parameters as a function of serial pump speed changes (revolutions per minute [rpm])-are increasingly used to evaluate function and malfunction of continuous-flow left ventricular assist devices (CF-LVADs). We hypothesized that ramp studies can predict...... patients (HeartMate II, Thoratec Corporation, Pleasanton, CA). Functional status was evaluated in 70% (31/44); average 6 minute walk test (6MWT) was 312 ± 220 min, New York Heart Association (NYHA) I-II/III-IV (70/30%) and activity scores very low-low/moderate-very high (55/45%). Decrease in pulmonary...

  12. Changes after surgically-assisted maxillary expansion (SARME) to the dentoalveolar, palatal and nasal structures by using tooth-borne distraction devices.

    Science.gov (United States)

    Seeberger, Robin; Kater, Wolfgang; Schulte-Geers, Michael; Davids, Rolf; Freier, Kolja; Thiele, Oliver

    2011-07-01

    Different devices are available to aid surgically-assisted maxillary expansion. In this study we have evaluated the changes to the anchoring teeth, the hard palate, and the lower nasal passage made by tooth-borne distraction devices. Thirty-one patients (mean (SD) age 28 (2) years) with deficiencies in the transverse width of the maxilla were examined by computed tomography and cone beam scans before and after operation. The data were analysed with the help of Wilcoxon's signed rank test and Spearman's r correlation. The mean (SD) distraction width was 6.5 (2.3) mm. All anchorage teeth were tilted (pdistraction width, with changes in the intercoronal and interapical distances of the anchoring premolars (pdistraction width and the overall gain in width of the lower nasal passage (pmaxillary expansion with tooth-borne devices has significant effects on the anchoring teeth, the nasal floor, and the hard palate. Both tilting of the teeth and an evenly distributed movement of the segments were seen. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  14. Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Mahoney, Edward; Tatooles, Antone

    Despite the high prevalence of depression and anxiety in patients with advanced heart failure, the effects of left ventricular assist device (LVAD) implantation on these critically important aspects of mental health are not well understood. We sought to assess changes in depression and anxiety following LVAD implantation. The Beck Depression Inventory-II (BDI-II) and Beck Anxiety Inventory (BAI) were administered to 54 patients by a clinical psychologist at a mean of 12 days before LVAD implantation and 251 days after implantation. Patient demographics and clinical data were collected concurrently to psychologic testing. Changes in BDI-II, BAI, and clinical markers of heart failure were assessed using paired t-tests. A p Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  15. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  16. Alexa, Siri, Cortana, and More: An Introduction to Voice Assistants.

    Science.gov (United States)

    Hoy, Matthew B

    2018-01-01

    Voice assistants are software agents that can interpret human speech and respond via synthesized voices. Apple's Siri, Amazon's Alexa, Microsoft's Cortana, and Google's Assistant are the most popular voice assistants and are embedded in smartphones or dedicated home speakers. Users can ask their assistants questions, control home automation devices and media playback via voice, and manage other basic tasks such as email, to-do lists, and calendars with verbal commands. This column will explore the basic workings and common features of today's voice assistants. It will also discuss some of the privacy and security issues inherent to voice assistants and some potential future uses for these devices. As voice assistants become more widely used, librarians will want to be familiar with their operation and perhaps consider them as a means to deliver library services and materials.

  17. Getting home with artifical heart – what is the everyday life experience of people with mechanical circulatory Support. A qualitative study

    Science.gov (United States)

    Braunsdorf, Sandy

    2017-07-01

    Background: The growing number of mechanical circulatory support systems implanted with successful results in terms of quality of life and physical resilience means that more and more people are being discharged from hospital to live at home with an artificial heart. This puts high requirements on affected persons’ disease and therapy management – a subject which has attracted very little qualitative research to date. Aim: This study therefore sought to shed light on how people with mechanical circulatory support experience their everyday lives. The aim was to document the subjective associations of those affected from an insider perspective. Methods: Following the interpretative phenomenological paradigm, narrative interviews were conducted with two female and eight male participants. For qualitative analysis, a multi-step process guided by the methodology of hermeneutic philosophy was used. Results: The qualitative data analysis revealed five main topic areas. These describe patients’ state of health after implantation and the various adjustments, constraints and pressures necessitated by their illness and therapeutic requirements. On this basis, coping and management strategies are identified. Other significant aspects of patients’ everyday lives are social interaction and environment and health care with an artificial heart. Conclusions: The findings add to our knowledge of the day-to-day lives of people with mechanical circulatory support systems, giving us a better understanding of their specific situation.

  18. IDEA. VOCES: A Mnemonic Device to Cue Mood Selection after Impersonal Expressions.

    Science.gov (United States)

    Chandler, Paul Michael

    1996-01-01

    Providing language learners with mnemonic devices assists retention and recall of vocabulary and structural items. This idea provides one such memory device to assist beginning and intermediate students who struggle with mood selection after impersonal expressions. (five references) (Author)

  19. The Impact of Ventricular Assist Device Prior to Transplantation on Morphological Parameters in Cardiac Allografts

    DEFF Research Database (Denmark)

    Wassilew, Katharina

    2017-01-01

    . The Cochran-Mantel-Haenzsel test was applied to assess significance of the differences in interactions between groups. To evaluate the impact of bridge- to- transplant mechanical circulatory support on development on transplant vasculopathy in cardiac allografts, the intramyocardial terminal arterial network...... allograft dysfunction, as MCS patients show a higher frequency of antibody-mediated rejection (AMR) episodes. We aimed to analyze the effects of MCS on cardiac AMR with regards to capillary C3d and C4d depositions. Regarding the functional parameters, both acute cellular rejection (ACR) and an increase...... of interstitial fibrosis (IF) often correlate with impaired ventricular function. The innate immune system, in particular macrophages, plays an important role in the resorptive process of ACR and is, on the other hand, known to promote IF. In this study we aimed to analyze the effect of ACR and specifically...

  20. Assessment of Safety and Effectiveness of the Extracorporeal Continuous-Flow Ventricular Assist Device (BR16010) Use as a Bridge-to-Decision Therapy for Severe Heart Failure or Refractory Cardiogenic Shock: Study Protocol for Single-Arm Non-randomized, Uncontrolled, and Investigator-Initiated Clinical Trial.

    Science.gov (United States)

    Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro

    2018-06-08

    The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device

  1. Human-robot interaction strategies for walker-assisted locomotion

    CERN Document Server

    Cifuentes, Carlos A

    2016-01-01

    This book presents the development of a new multimodal human-robot interface for testing and validating control strategies applied to robotic walkers for assisting human mobility and gait rehabilitation. The aim is to achieve a closer interaction between the robotic device and the individual, empowering the rehabilitation potential of such devices in clinical applications. A new multimodal human-robot interface for testing and validating control strategies applied to robotic walkers for assisting human mobility and gait rehabilitation is presented. Trends and opportunities for future advances in the field of assistive locomotion via the development of hybrid solutions based on the combination of smart walkers and biomechatronic exoskeletons are also discussed. .

  2. Continuous flow left ventricular assist devices: shared care goals of monitoring and treating patients.

    Science.gov (United States)

    Estep, Jerry D; Trachtenberg, Barry H; Loza, Laurie P; Bruckner, Brian A

    2015-01-01

    Continuous-flow left ventricular assist devices (CF-LVADs) have been clinically adopted as a long-term standard of care therapy option for patients with end-stage heart failure. For many patients, shared care between the care providers at the implanting center and care providers in the community in which the patient resides is a clinical necessity. The aims of this review are to (1) provide a rationale for the outpatient follow-up exam and surveillance testing used at our center to monitor patients supported by the HeartMate II(®) CF-LVAD (Thoratec Corporation, Pleasanton, CA) and (2) provide the protocol/algorithms we use for blood pressure, driveline exit site, LVAD alarm history, surveillance blood work, and echocardiography monitoring in this patient population. In addition, we define our partnership outpatient follow-up protocol and the "shared care" specific responsibilities we use with referring health care providers to best manage many of our patients.

  3. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  4. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    Science.gov (United States)

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  5. Vacuum-assisted closure device as a split-thickness skin graft bolster in the burn population.

    Science.gov (United States)

    Waltzman, Joshua T; Bell, Derek E

    2014-01-01

    The vacuum-assisted closure device (VAC) is associated with improved wound healing outcomes. Its use as a bolster device to secure a split-thickness skin graft has been previously demonstrated; however, there is little published evidence demonstrating its benefits specifically in the burn population. With use of the VAC becoming more commonplace, its effect on skin graft take and overall time to healing in burn patients deserves further investigation. Retrospective review of burn registry database at a high-volume level I trauma center and regional burn center during a 16-month period was performed. Patients who had a third-degree burn injury requiring a split-thickness skin graft and who received a VAC bolster were included. Data points included age, sex, burn mechanism, burn location, grafted area in square centimeters, need for repeat grafting, percent graft take, and time to complete reepithelialization. Sixty-seven patients were included in the study with a total of 88 skin graft sites secured with a VAC. Age ranged from skin graft in the burn population. The observed rate of zero returns to the operating room for repeat grafting was especially encouraging. Its ability to conform to contours of the body and cover large surface areas makes it especially useful in securing a graft. This method of bolstering results in decreased repeat grafting and minimal graft loss, thus decreasing morbidity compared with conventional bolster dressings.

  6. Towards an Artificial Phonological Loop: An Assistive Device for Working Memory and Attentional Control

    Directory of Open Access Journals (Sweden)

    D. Bogen

    2006-01-01

    Full Text Available We describe the initial development of an artificial phonological loop (APL, a new technology to assist individuals with impairment of the working memory system. The phonological loop, along with the visuospatial sketchpad, is one of the two slave short-term memory subsystems that comprise working memory, a cognitive function closely associated with the control of attention. In the phonological loop, phonological (speech information lasting for 1–2 second is maintained active by repetitive, subvocal (silent speech rehearsal. Deficits in working memory, specifically in the phonological loop, occur in many disorders, including attention-deficit disorder and Alzheimer’s disease. In these disorders, it appears that the ability for phonological rehearsal is intact, but the regulation or triggering of the rehearsal process is inadequate, thus causing the contents of working memory to be lost. The purpose, then, of the APL is to facilitate the phonological loop by artificially extending the duration of phonological rehearsals. The APL mimics the natural phonological loop by providing audible vocal echoes to take the place of subvocal rehearsals. In this system, the user talks to him/herself in short (1–2 second phrases; the device records these phrases, stores them in electronic memory, and then repeats— i.e., echoes—the phrases multiple times over an extended period. Two versions of this device have been developed: the Echo-APL and the Rearticulation-APL. In the Echo-APL, only echoing is involved. In the Rearticulation-APL, however, the user re-vocalizes (rearticulates the phrase in response to an audible cue. The device repeats the cue until it detects (hears the re-vocalization. Future research and development of the APL will require extensive testing and careful evaluation of possible echo-schedules: the predefined program controlling inter-echo time intervals and echo-amplitude (echo loudness. The APL essentially exteriorizes the silent

  7. Soft robotic devices for hand rehabilitation and assistance: a narrative review.

    Science.gov (United States)

    Chu, Chia-Ye; Patterson, Rita M

    2018-02-17

    The debilitating effects on hand function from a number of a neurologic disorders has given rise to the development of rehabilitative robotic devices aimed at restoring hand function in these patients. To combat the shortcomings of previous traditional robotics, soft robotics are rapidly emerging as an alternative due to their inherent safety, less complex designs, and increased potential for portability and efficacy. While several groups have begun designing devices, there are few devices that have progressed enough to provide clinical evidence of their design's therapeutic abilities. Therefore, a global review of devices that have been previously attempted could facilitate the development of new and improved devices in the next step towards obtaining clinical proof of the rehabilitative effects of soft robotics in hand dysfunction. A literature search was performed in SportDiscus, Pubmed, Scopus, and Web of Science for articles related to the design of soft robotic devices for hand rehabilitation. A framework of the key design elements of the devices was developed to ease the comparison of the various approaches to building them. This framework includes an analysis of the trends in portability, safety features, user intent detection methods, actuation systems, total DOF, number of independent actuators, device weight, evaluation metrics, and modes of rehabilitation. In this study, a total of 62 articles representing 44 unique devices were identified and summarized according to the framework we developed to compare different design aspects. By far, the most common type of device was that which used a pneumatic actuator to guide finger flexion/extension. However, the remainder of our framework elements yielded more heterogeneous results. Consequently, those results are summarized and the advantages and disadvantages of many design choices as well as their rationales were highlighted. The past 3 years has seen a rapid increase in the development of soft robotic

  8. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproductive microscopes and microscope... Devices § 884.6190 Assisted reproductive microscopes and microscope accessories. (a) Identification. Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are...

  9. Optimal Timing of Heart Transplant After HeartMate II Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Steffen, Robert J; Blackstone, Eugene H; Smedira, Nicholas G; Soltesz, Edward G; Hoercher, Katherine J; Thuita, Lucy; Starling, Randall C; Mountis, Maria; Moazami, Nader

    2017-11-01

    Optimal timing of heart transplantation in patients supported with second-generation left ventricular assist devices (LVADs) is unknown. Despite this, patients with LVADs continue to receive priority on the heart transplant waiting list. Our objective was to determine the optimal timing of transplantation for patients bridged with continuous-flow LVADs. A total of 301 HeartMate II LVADs (Thoratec Corp, Pleasanton, CA) were implanted in 285 patients from October 2004 to June 2013, and 86 patients underwent transplantation through the end of follow-up. Optimal transplantation timing was the product of surviving on LVAD support and surviving transplant. Three-year survival after both HeartMate II implantation and heart transplantation was unchanged when transplantation occurred within 9 months of implantation. Survival decreased as the duration of support exceeded this. Preoperative risk factors for death on HeartMate II support were prior valve operation, prior coronary artery bypass grafting, low albumin, low glomerular filtration rate, higher mean arterial pressure, hypertension, and earlier date of implant. Survival for patients without these risk factors was lowest when transplant was performed within 3 months but was relatively constant with increased duration of support. Longer duration of support was associated with poorer survival for patients with many of these risk factors. Device reimplantation, intracranial hemorrhage, and postimplant dialysis during HeartMate II support were associated with decreased survival. Survival of patients supported by the HeartMate II is affected by preoperative comorbidities and postoperative complications. Transplantation before complications is imperative in optimizing survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device

    DEFF Research Database (Denmark)

    Jung, Mette H; Hassager, Christian; Balling, Louise

    2015-01-01

    Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous......-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting...

  11. Intelligent speed adaptation as an assistive device for drivers with acquired brain injury: a single-case field experiment.

    Science.gov (United States)

    Klarborg, Brith; Lahrmann, Harry; NielsAgerholm; Tradisauskas, Nerius; Harms, Lisbeth

    2012-09-01

    Intelligent speed adaptation (ISA) was tested as an assistive device for drivers with an acquired brain injury (ABI). The study was part of the "Pay as You Speed" project (PAYS) and used the same equipment and technology as the main study (Lahrmann et al., in press-a, in press-b). Two drivers with ABI were recruited as subjects and had ISA equipment installed in their private vehicle. Their speed was logged with ISA equipment for a total of 30 weeks of which 12 weeks were with an active ISA user interface (6 weeks=Baseline 1; 12 weeks=ISA period; 12 weeks=Baseline 2). The subjects participated in two semi-structured interviews concerning their strategies for driving with ABI and for driving with ISA. Furthermore, they gave consent to have data from their clinical journals and be a part of the study. The two subjects did not report any instances of being distracted or confused by ISA, and in general they described driving with ISA as relaxed. ISA reduced the percentage of the total distance that was driven with a speed above the speed limit (PDA), but the subjects relapsed to their previous PDA level in Baseline 2. This suggests that ISA is more suited as a permanent assistive device (i.e. cognitive prosthesis) than as a temporary training device. As ABI is associated with a multitude of cognitive deficits, we developed a conceptual framework, which focused on the cognitive parameters that have been shown to relate to speeding behaviour, namely "intention to speed" and "inattention to speeding". The subjects' combined status on the two independent parameters made up their "speeding profile". A comparison of the speeding profiles and the speed logs indicated that ISA in the present study was more efficient in reducing inattention to speeding than affecting intention to speed. This finding suggests that ISA might be more suited for some neuropsychological profiles than for others, and that customisation of ISA for different neuropsychological profiles may be required

  12. Life expectancy and death by diseases of the circulatory system in patients with bipolar disorder or schizophrenia in the Nordic countries

    DEFF Research Database (Denmark)

    Laursen, Thomas Munk; Wahlbeck, Kristian; Hällgren, Jonas

    2013-01-01

    Excess mortality from diseases and medical conditions (natural death) in persons with psychiatric disorders has been extensively reported. Even in the Nordic countries with well-developed welfare systems, register based studies find evidence of an excess mortality. In recent years, cardiac...... mortality and death by diseases of the circulatory system has seen a decline in all the Nordic countries, but a recent paper indicates that women and men in Denmark, Finland, and Sweden, who had been hospitalised for a psychotic disorder, had a two to three-fold increased risk of dying from a cardiovascular...... disease. The aim of this study was to compare the mortality by diseases of the circulatory system among patients with bipolar disorder or schizophrenia in the three Nordic countries Denmark, Sweden, and Finland. Furthermore, the aim was to examine and compare life expectancy among these patients. Cause...

  13. Towards automated assistance for operating home medical devices.

    Science.gov (United States)

    Gao, Zan; Detyniecki, Marcin; Chen, Ming-Yu; Wu, Wen; Hauptmann, Alexander G; Wactlar, Howard D

    2010-01-01

    To detect errors when subjects operate a home medical device, we observe them with multiple cameras. We then perform action recognition with a robust approach to recognize action information based on explicitly encoding motion information. This algorithm detects interest points and encodes not only their local appearance but also explicitly models local motion. Our goal is to recognize individual human actions in the operations of a home medical device to see if the patient has correctly performed the required actions in the prescribed sequence. Using a specific infusion pump as a test case, requiring 22 operation steps from 6 action classes, our best classifier selects high likelihood action estimates from 4 available cameras, to obtain an average class recognition rate of 69%.

  14. Mobile Learning Devices. Essentials for Principals

    Science.gov (United States)

    Rogers, Kipp D.

    2011-01-01

    In "Mobile Learning Devices," the author helps educators confront and overcome their fears and doubts about using mobile learning devices (MLDs) such as cell phones, personal digital assistants, MP3 players, handheld games, digital audio players, and laptops in classrooms. School policies that ban such tools are outdated, the author suggests;…

  15. The risk mortality of the population of azerbaijan from circulatory diseases, depending on the season

    Directory of Open Access Journals (Sweden)

    A. J. Rzayeva

    2015-06-01

    Azerbaijan State Advanced Training Institute for doctors named after A. Aliyev, Baku   ABSTRACT The Objective.  To obtain evidence-based data about the role of seasons of the year in the formation of the population mortality risk from the circulatory system diseases  (CSD in Azerbaijan and its regions with specific climate. Materials of the study. A case of mortality was a unit of statistical observation. The fatalities from all reasons, including CSD have been distributed by the days of every month in the year. Daily average amount of fatalities by months and seasons ( from 20 December to 19 March – winter; from 20 March to 19 June- spring; from 20 June to 16 September; from 20 September to 19 December - autumn have been determined. Results.  In Azerbaijan the risk of general mortality and mortality from CSD is the highest in winter, it decreases in spring but nonuniformly (the general mortality rate is less than that from CSD. That is why the share of CSD increases among mortality reasons. Conclusions. Seasonal change of mortality risks from CSD is multivariant. Winter-spring increase of risk predominates in Azerbaijan. In some regions of Azerbaijan the mortality risk from CSD increases only once either in spring or in summer or winter. Key words: seasonal dynamics, risk of mortality, circulatory system diseases.

  16. Developing Seventh Grade Students’ Systems Thinking Skills in the Context of the Human Circulatory System

    Science.gov (United States)

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students’ systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students’ systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students’ systems thinking components and examine possible changes in the students’ knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students’ ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems’ components and its processes within a framework of relationships, namely the students’ systems thinking skills were improved in the course of learning using the teaching and learning materials. PMID:25520948

  17. Developing seventh grade students' systems thinking skills in the context of the human circulatory system.

    Science.gov (United States)

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students' systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students' systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students' systems thinking components and examine possible changes in the students' knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students' ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems' components and its processes within a framework of relationships, namely the students' systems thinking skills were improved in the course of learning using the teaching and learning materials.

  18. Diseases of the circulatory system among adult people diagnosed with infantile autism as children

    DEFF Research Database (Denmark)

    Mouridsen, Svend Erik; Rich, Bente; Isager, Torben

    2016-01-01

    BACKGROUND: Research dealing with adult people with autism spectrum disorders (ASD) noticeably lags behind studies of children and young individuals with ASD. AIMS: The objective of this study was to compare the prevalence and types of diseases of the circulatory system in a clinical sample of 118...... adult people diagnosed with infantile autism (IA) as children with 336 sex and age matched controls from the general population. METHODS AND PROCEDURES: All participants were screened through the nationwide Danish National Hospital Register. The average observation time of both groups was 37.2 years...

  19. Interaction design concepts for a mobile personal assistant

    NARCIS (Netherlands)

    Nagata, S.F.; Oostendorp, H. van; Neerincx, M.A.

    2004-01-01

    The Personal Assistant for onLine Services (PALS) project aims to develop an intelligent interface that facilitates efficient user interaction through personalization and context awareness with commerce web sites on a handheld device. The types of assistance services and interaction support

  20. Neonatal aortic arch reconstruction avoiding circulatory arrest and direct arch vessel cannulation.

    Science.gov (United States)

    Tchervenkov, C I; Korkola, S J; Shum-Tim, D; Calaritis, C; Laliberté, E; Reyes, T U; Lavoie, J

    2001-11-01

    Aortic arch reconstruction in neonates routinely requires deep hypothermic circulatory arrest. We reviewed our experience with techniques of continuous low-flow cerebral perfusion (LFCP) avoiding direct arch vessel cannulation. Eighteen patients, with a median age of 11 days (range 1 to 85 days) and a mean weight of 3.2 +/- 0.8 kg, underwent aortic arch reconstruction with LFCP. Seven had biventricular repairs with arch reconstruction, 9 underwent the Norwood operation and 2 had isolated arch repairs. In 1 Norwood and 7 biventricular repair patients, LFCP was maintained by advancing the cannula from the distal ascending aorta into the innominate artery. In 8 of 9 Norwood patients, LFCP was maintained by directing the arterial cannula into the pulmonary artery confluence and perfusing the innominate artery through the right modified Blalock-Taussig shunt fully constructed before cannulation for cardiopulmonary bypass. In 2 patients requiring isolated arch reconstruction, the ascending aorta was cannulated and the cross-clamp was applied just distal to the innominate artery. LFCP was maintained at 0.6 +/- 0.2 L x min(-1) x m(-2) for 41.0 +/- 13.9 minutes at 18.5 degrees C +/- 1.1 degrees C. In 10 of the 18 patients, blood pressure during LFCP was 15 +/- 8 mm Hg remote from the innominate artery (left radial, umbilical or femoral arteries). In 8 of the 18 patients, right radial pressure during LFCP was 24 +/- 10 mm Hg. The mean mixed-venous saturation was 79.8% +/- 10% during LFCP. Two patients had preoperative seizures, whereas none had seizures postoperatively. One patient died. Neonatal aortic arch reconstruction is possible without circulatory arrest or direct arch vessel cannulation. These techniques maintained adequate mixed-venous oxygen saturations with no associated adverse neurologic outcomes.

  1. 34 CFR 300.6 - Assistive technology service.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Assistive technology service. 300.6 Section 300.6 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION... selection, acquisition, or use of an assistive technology device. The term includes— (a) The evaluation of...

  2. Is there an association of circulatory hospitalizations independent of mining employment in coal-mining and non-coal-mining counties in west virginia?

    Science.gov (United States)

    Talbott, Evelyn O; Sharma, Ravi K; Buchanich, Jeanine; Stacy, Shaina L

    2015-04-01

    Exposures associated with coal mining activities, including diesel fuel exhaust, products used in coal processing, and heavy metals and other forms of particulate matter, may impact the health of nearby residents. We investigated the relationships between county-level circulatory hospitalization rates (CHRs) in coal and non-coal-mining communities of West Virginia, coal production, coal employment, and sociodemographic factors. Direct age-adjusted CHRs were calculated using West Virginia hospitalizations from 2005 to 2009. Spatial regressions were conducted to explore associations between CHR and total, underground, and surface coal production. After adjustment, neither total, nor surface, nor underground coal production was significantly related to rate of hospitalization for circulatory disease. Our findings underscore the significant role sociodemographic and behavioral factors play in the health and well-being of coal mining communities.

  3. Assistive Technology Needs Assessment from Adolescent Students with Hearing Loss and Their Parents, Ahvaz City-2013

    Directory of Open Access Journals (Sweden)

    Ma'soumeh Zaman-Pour

    2015-01-01

    Full Text Available Objective: The purpose of this study was to assess assistive devices needs of adolescent students with hearing impairment in Ahvaz city. Materials & Methods: Although 69(96% students had digital hearing aids 44(61% reported difficulties in watching television, 66 (92% in using alarm clocks, 24(33% in hearing door and telephone ringing, 63(88% in using telephone, 14(19% in face to face communication and 46 (64% in class participation. Almost none of the participants were aware of existence of above mentioned assistive devices. After introducing the devices, each of the devices, were reported to be highly needed by 2 (3% to 69 (96% students and their parents. Results: Although 69 (96% students had digital hearing aids, 44 (61% were reported to have difficulties in watching television, 66 (92% in using alarm clocks, 24 (33% in hearing door and telephone ringing, 63 (88% in using telephone, 14 (19% in face to face communication and 46 (64% in class participation. Almost none of the participants were aware of existence of above mentioned assistive devices. After introducing the devices, between 2 (3% to 69 (96% were reported to need each device. Conclusion: Adolescents with hearing impairment should be widely informed of assistive devices which could be useful to them. Findings on this study could be use in planning for providing assistive devices for adolescents with hearing impairments.

  4. Wave Intensity Analysis of Right Ventricular Function during Pulsed Operation of Rotary Left Ventricular Assist Devices.

    Science.gov (United States)

    Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod

    2018-05-29

    Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.

  5. The extent of using mobility assistive devices can partly explain fatigue among persons with late effects of polio - a retrospective registry study in Sweden.

    Science.gov (United States)

    Santos Tavares Silva, I; Sunnerhagen, K S; Willén, C; Ottenvall Hammar, I

    2016-11-18

    Fatigue is reported as one of the most disabling symptoms and is common among persons living with late effects of polio. Although fatigue has been studied in the context of people living with late effects of polio, there is a lack of knowledge concerning the association of fatigue and variables of importance for participation in daily life. Therefore, the aim of this study was to explore possible factors associated with fatigue among persons with late effects of polio in Sweden. This retrospective registry study consisted of 89 persons with late effects of polio living in Sweden. Fatigue was measured with the Multidimensional Fatigue Inventory (MFI-20) scale, Swedish version. Pearson's correlation coefficient was used to analyse the correlation between the factors and fatigue, and a multiple linear regression was carried out to explore factors for fatigue. Fatigue statistically significantly correlated with age (r = 0.234, p polio, and the model partly explained 14% of the variation of fatigue. Fatigue could partly be explained by the extent of using mobility assistive devices and age. Healthcare professionals should provide and demonstrate the importance of assistive devices to ensure management of fatigue in persons living with late effects of polio.

  6. A brain-computer interface as input channel for a standard assistive technology software.

    Science.gov (United States)

    Zickler, Claudia; Riccio, Angela; Leotta, Francesco; Hillian-Tress, Sandra; Halder, Sebastian; Holz, Elisa; Staiger-Sälzer, Pit; Hoogerwerf, Evert-Jan; Desideri, Lorenzo; Mattia, Donatella; Kübler, Andrea

    2011-10-01

    Recently brain-computer interface (BCI) control was integrated into the commercial assistive technology product QualiWORLD (QualiLife Inc., Paradiso-Lugano, CH). Usability of the first prototype was evaluated in terms of effectiveness (accuracy), efficiency (information transfer rate and subjective workload/NASA Task Load Index) and user satisfaction (Quebec User Evaluation of Satisfaction with assistive Technology, QUEST 2.0) by four end-users with severe disabilities. Three assistive technology experts evaluated the device from a third person perspective. The results revealed high performance levels in communication and internet tasks. Users and assistive technology experts were quite satisfied with the device. However, none could imagine using the device in daily life without improvements. Main obstacles were the EEG-cap and low speed.

  7. Influence of vascular network design on gas transfer in lung assist device technology.

    Science.gov (United States)

    Bassett, Erik K; Hoganson, David M; Lo, Justin H; Penson, Elliot J N; Vacanti, Joseph P

    2011-01-01

    Blood oxygenators are vital for the critically ill, but their use is limited to the hospital setting. A portable blood oxygenator or a lung assist device for ambulatory or long-term use would greatly benefit patients with chronic lung disease. In this work, a biomimetic blood oxygenator system was developed which consisted of a microfluidic vascular network covered by a gas permeable silicone membrane. This system was used to determine the influence of key microfluidic parameters-channel size, oxygen exposure length, and blood shear rate-on blood oxygenation and carbon dioxide removal. Total gas transfer increased linearly with flow rate, independent of channel size and oxygen exposure length. On average, CO(2) transfer was 4.3 times higher than oxygen transfer. Blood oxygen saturation was also found to depend on the flow rate per channel but in an inverse manner; oxygenation decreased and approached an asymptote as the flow rate per channel increased. These relationships can be used to optimize future biomimetic vascular networks for specific lung applications: gas transfer for carbon dioxide removal in patients with chronic obstructive pulmonary disease or oxygenation for premature infants requiring complete lung replacement therapy.

  8. Liquid Self-Balancing Device Effects on Flexible Rotor Stability

    Directory of Open Access Journals (Sweden)

    Leonardo Urbiola-Soto

    2013-01-01

    Full Text Available Nearly a century ago, the liquid self-balancing device was first introduced by M. LeBlanc for passive balancing of turbine rotors. Although of common use in many types or rotating machines nowadays, little information is available on the unbalance response and stability characteristics of this device. Experimental fluid flow visualization evidences that radial and traverse circulatory waves arise due to the interaction of the fluid backward rotation and the baffle boards within the self-balancer annular cavity. The otherwise destabilizing force induced by trapped fluids in hollow rotors, becomes a stabilizing mechanism when the cavity is equipped with adequate baffle boards. Further experiments using Particle Image Velocimetry (PIV enable to assess the active fluid mass fraction to be one-third of the total fluid mass. An analytical model is introduced to study the effects of the active fluid mass fraction on a flexible rotor supported by flexible supports excited by bwo different destabilizing mechanisms; rotor internal friction damping and aerodynamic cross-coupling. It is found that the fluid radial and traverse forces contribute to the balancing action and to improve the rotor stability, respectively.

  9. The ‘abdominal circulatory pump’: an auxiliary heart during exercise?

    Directory of Open Access Journals (Sweden)

    Barbara eUva

    2016-01-01

    Full Text Available Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25±7yr, 70±11kg, 1.78±0.1m, 3F performed plantar flexion exercise at ∼4 METs. Changes in body volume (ΔVb and trunk volume (ΔVtr were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE, rib cage (RCE, voluntary emphasized inspiratory rib cage breathing and abdominal (ABE, voluntary active abdominal expiration breathing.. During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16± 0.33L and 0.48±0.55L, p<0.05 SE vs RCE, while during ABE it was displaced from the trunk to the extremities (0.22±0.20L p<0.001, p<0.05 RCE and SE vs ABE respectively. At baseline, Vbs swings (maximum to minimum amplitude were bimodal and averaged 0.13±0.08L. During exercise, Vbs swings consistently increased (0.42±0.34L, 0.40±0.26L, 0.46±0.21L, for SE, RCE and ABE respectively, all p<0.01 vs. baseline. It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an ‘auxiliary heart’.

  10. Dynamics of device innovation: implications for assessing value.

    Science.gov (United States)

    Gelijns, Annetine C; Russo, Mark J; Hong, Kimberly N; Brown, Lawrence D; Ascheim, Deborah D; Moskowitz, Alan J

    2013-10-01

    In recent years, there has been growing interest in evaluating the health and economic impact of medical devices. Payers increasingly rely on cost-effectiveness analyses in making their coverage decisions, and are adopting value-based purchasing initiatives. These analytic approaches, however, have been shaped heavily by their use in the pharmaceutical realm, and are ill-adapted to the medical device context. This study focuses on the development and evaluation of left ventricular assist devices (LVADs) to highlight the unique challenges involved in the design and conduct of device trials compared with pharmaceuticals. Devices are moving targets characterized by a much higher degree of post-introduction innovation and "learning by using" than pharmaceuticals. The cost effectiveness ratio of left ventricular assist devices for destination therapy, for example, decreased from around $600,000 per life year saved based on results from the pivotal trial to around $100,000 within a relatively short time period. These dynamics pose fundamental challenges to the evaluation enterprise as well as the policy-making world, which this paper addresses.

  11. When withdrawal of life-sustaining care does more than allow death to take its course: the dilemma of left ventricular assist devices.

    Science.gov (United States)

    Bramstedt, K A; Wenger, N S

    2001-05-01

    Left ventricular assist devices (LVADs) are a relatively new technology that is increasingly used to preserve cardiac function. These devices work by a mechanism that may complicate ethical decision-making for patients who subsequently lose decision-making capacity and are no longer considered transplant candidates. Using a clinical case from our medical center, we explored the complex ethical issues associated with the discontinuation of LVAD therapy by discussing how this device is distinct from the withdrawal of other treatments. While halting an implanted LVAD may permit a patient to die, the deactivated device itself may contribute to patient death due to the potential for blood backflow and pooling, as well as the disruption of heart contractility. Inadequate informed consent and failure to appoint a surrogate decision-maker in advance of the implant procedure resulted in a complex ethical dilemma for the patient's family and the medical team. Clinicians and families must consider the benefits and burdens of LVAD therapy as they do when considering removal of other life-sustaining treatment. The informed consent process associated with LVADs as bridging technology should include extensive consideration of the purpose of the device, future circumstances in which it may be halted, and how such situations would be recognized and handled. Appointment of a surrogate decision-maker before the surgical procedure is essential.

  12. A guide for approval of nuclear gauging devices

    International Nuclear Information System (INIS)

    1990-01-01

    This guide has been written to assist manufacturers, distributors and users of nuclear gauging devices in the preparation of a submission to the Atomic Energy Control Board in support of a request for approval of a nuclear gauging device

  13. Theoretical and experimental analysis of a solar thermoelectric power generation device based on gravity-assisted heat pipes and solar irradiation

    International Nuclear Information System (INIS)

    Zhang, Zhe; Li, Wenbin; Kan, Jiangming; Xu, Daochun

    2016-01-01

    Highlights: • A technical solution to the power supply of wireless sensor networks is presented. • The low voltage produced by device is boosted from around 1 V to more than 4 V. • An output current and voltage of the device is acquired as 343 mA and 1057 mV. • The device provides output power 362.56 mW in no electricity conditions. • The economic value of device is demonstrated. - Abstract: Solar thermoelectric power generation has been widely used to solve the power supply limitation issue for low-power wireless sensors because of its light weight, high reliability, low cost, lack of noise, and environmental friendliness. A solar thermoelectric power generation system based on gravity-assisted heat pipes and solar radiation is devised in this paper, and its behavior is continuously measured in realistic outdoor circumstances. The effects of key parameters, including solar luminous flux, load resistance, a proportional coefficient, and a relative Seebeck coefficient, are analyzed. Related experimental results show that the device can output a voltage of 1057 mV and an electrical current of 343 mA, resulting in an output power of 362.56 mW. With a stable external energy conversion module under aluminous flux of 7.81 × 10"4 lx, the voltage converted from the nature solar radiation is boosted from 1057 mV to 4.40 V, which meets the rated operating voltage of low power consumption components, such as low-power wireless sensors and ZigBee modules. An economic analysis of the system shows that the solar thermoelectric power generation device is both economically and technically competitive when it is applied in a low-voltage wireless sensor network.

  14. Neurohormonal activation and exercise tolerance in patients supported with a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Jung, Mette Holme; Goetze, Jens Peter; Boesgaard, Soeren

    2016-01-01

    BACKGROUND: Neurohormones play a key role in regulating hemodynamics in heart failure (HF) both at rest and during exercise. In contrast, little is known about the importance of neurohormonal regulation for exercise capacity in continuous-flow left ventricular assist device (CF-LVAD) patients....... The aim of this study was to assess the relation between neurohormonal activation patterns in CF-LVAD patients and exercise capacity. METHODS: Plasma concentrations of the C-terminal portion of pro-arginine vasopressin precursor (copeptin), pro-adrenomedullin (proADM), pro-B-type (proBNP) and pro......-atrial (proANP) natriuretic peptides were measured in 25 CF-LVAD patients (HeartMate II) in the morning prior to maximal cardiopulmonary exercise testing determining peak oxygen uptake (peak VO2). Quality of life (QOL) was determined by questionnaires. RESULTS: Peak VO2 was severely reduced averaging 13...

  15. Theoretic models for recommendation and implementation of assistive technology

    Directory of Open Access Journals (Sweden)

    Ana Cristina de Jesus Alves

    2016-07-01

    Full Text Available Introduction: The latest international researches seek to understand the factors affecting the successful use of assistive technology devices through studies regarding the assessments systematizing; abandonment of devices; or theoric models that consider the aspects of those devices implementation. In Brazil the researches are focused on developing new technologies and there are still not sufficient studies related to the successful use of devices and ways of assistive technology implementation. Objective: To identify conceptual models used for indication and implementation of assistive technology devices. Method: Literature review. The survey was conducted in six databases: CINAHAL, Eric, GALE, LILACS, MEDLINE e PsycInfo. A critical analysis described by Grant and Booth was used. Results: There are no records of a Brazilian survey and among 29 selected articles, 17 conceptual models used in the area of AT were found; of these, 14 were specific to AT. The results showed that the new conceptual models of TA are under development and the conceptual model “Matching Person and Technology – MPT” was the most mentioned. Conclusion: We can observe that the practices related to TA area in international context shows a correlation with conceptual models, thus, we hope this study might have the capacity to contribute for the propagation of this precepts at national level

  16. 28 CFR 0.86 - Seizure of gambling devices.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Seizure of gambling devices. 0.86 Section... Bureau of Investigation § 0.86 Seizure of gambling devices. The Director, Associate Director, Assistants... General to make seizures of gambling devices (18 U.S.C. 1955(d), 15 U.S.C. 1171 et seq.) and wire or oral...

  17. Utilization of organs from donors after circulatory death for vascularized pancreas and islet of Langerhans transplantation : recommendations from an expert group

    NARCIS (Netherlands)

    Berney, Thierry; Boffa, Catherine; Augustine, Titus; Badet, Lionel; de Koning, Eelco; Pratschke, Johann; Socci, Carlo; Friend, Peter

    2015-01-01

    Donation after circulatory death (DCD) donors are increasingly being used as a source of pancreas allografts for vascularized organ and islet transplantation. We provide practice guidelines aiming to increase DCD pancreas utilization. We review risk assessment and donor selection criteria. We report

  18. Singularity now: using the ventricular assist device as a model for future human-robotic physiology.

    Science.gov (United States)

    Martin, Archer K

    2016-04-01

    In our 21 st century world, human-robotic interactions are far more complicated than Asimov predicted in 1942. The future of human-robotic interactions includes human-robotic machine hybrids with an integrated physiology, working together to achieve an enhanced level of baseline human physiological performance. This achievement can be described as a biological Singularity. I argue that this time of Singularity cannot be met by current biological technologies, and that human-robotic physiology must be integrated for the Singularity to occur. In order to conquer the challenges we face regarding human-robotic physiology, we first need to identify a working model in today's world. Once identified, this model can form the basis for the study, creation, expansion, and optimization of human-robotic hybrid physiology. In this paper, I present and defend the line of argument that currently this kind of model (proposed to be named "IshBot") can best be studied in ventricular assist devices - VAD.

  19. In vivo evaluation of zirconia ceramic in the DexAide right ventricular assist device journal bearing.

    Science.gov (United States)

    Saeed, Diyar; Shalli, Shanaz; Fumoto, Hideyuki; Ootaki, Yoshio; Horai, Tetsuya; Anzai, Tomohiro; Zahr, Roula; Horvath, David J; Massiello, Alex L; Chen, Ji-Feng; Dessoffy, Raymond; Catanese, Jacquelyn; Benefit, Stephen; Golding, Leonard A R; Fukamachi, Kiyotaka

    2010-06-01

    Zirconia is a ceramic with material properties ideal for journal bearing applications. The purpose of this study was to evaluate the use of zirconium oxide (zirconia) as a blood journal bearing material in the DexAide right ventricular assist device. Zirconia ceramic was used instead of titanium to manufacture the DexAide stator housing without changing the stator geometry or the remaining pump hardware components. Pump hydraulic performance, journal bearing reliability, biocompatibility, and motor efficiency data of the zirconia stator were evaluated in six chronic bovine experiments for 14-91 days and compared with data from chronic experiments using the titanium stator. Pump performance data including average in vivo pump flows and speeds using a zirconia stator showed no statistically significant difference to the average values for 16 prior titanium stator in vivo studies, with the exception of a 19% reduction in power consumption. Indices of hemolysis were comparable for both stator types. Results of coagulation assays and platelet aggregation tests for the zirconia stator implants showed no device-induced increase in platelet activation. Postexplant evaluation of the zirconia journal bearing surfaces showed no biologic deposition in any of the implants. In conclusion, zirconia ceramic can be used as a hemocompatible material to improve motor efficiency while maintaining hydraulic performance in a blood journal bearing application.

  20. Effect of 5E Instructional Model in Student Success in Primary School 6th Year Circulatory System Topic

    Science.gov (United States)

    Cardak, Osman; Dikmenli, Musa; Saritas, Ozge

    2008-01-01

    The aim of this study is to research the effect of the 5E instructional model on primary (sixth grade) student success during the circulatory system unit. This study was conducted with 38 students in two different classes by the same researcher in 2006-2007. One of the classes was assigned as the control group and the other as the experimental…

  1. [Mortality rates of circulatory system diseases and malignant neoplasms in Zagreb population younger than sixty-five--call for alarm].

    Science.gov (United States)

    Vizintin, Marina Polić; Mrcela, Nada Tomasović; Kovacić, Luka

    2012-12-01

    The aim of this work was to analyze the public health indicators for circulatory heart diseases and malignant neoplasms in the population younger than 65 in the City of Zagreb, Croatia, and compare them with the European Union (EU) countries. The purpose was to evaluate the situation and propose the public health preventive measures. The study population were Zagreb citizens aged 0-64 according to the 2001 census. Total Zagreb population was 779145, making 17.6% of total Croatian population. Data from the Croatian Bureau of Statistics and Dr Andrija Stampar Institute of Public Health were used. The standardized 0-64 mortality rates of the selected diseases 2006-2010 were used in the analysis. In 2010, the standardized mortality rates of all analyzed diseases were significantly higher in Zagreb population aged 0-64 than the EU averages except for cervical cancer. In 2010, the mortality rates in Zagreb population aged 0-64 were as follows: circulatory system diseases 61.22, ischemic heart disease 28.99, cerebrovascular diseases 12.51, malignant neoplasms 94.69, tracheal and lung cancer 24.92, breast cancer 21.08 and cervical cancer 2.05. Standardized mortality rates in Zagreb population aged 0-64 for circulatory system were lower than for Croatia (61.22 vs. 63.25), but higher for malignant neoplasms (94.69 vs. 91.2), except for cervical cancer (2.05 vs. 3.14). High standardized mortality rates for the selected diseases in the City of Zagreb, Croatia, were observed. The rates were higher in Zagreb population compared to EU averages except for cervical cancer. This situation urges revision of the public health strategy and implementation of more intensive preventive and screening measures to reduce the risk factors.

  2. GP-support by means of AGnES-practice assistants and the use of telecare devices in a sparsely populated region in Northern Germany – proof of concept

    Directory of Open Access Journals (Sweden)

    Scriba Sibylle

    2009-06-01

    Full Text Available Abstract Background In many rural regions in Germany, the proportion of the elderly population increases rapidly. Simultaneously, about one-third of the presently active GPs will retire until 2010. Often it is difficult to find successors for vacant GP-practices. These regions require innovative concepts to avoid the imminent shortage in primary health care. The AGnES-concept comprises the delegation of GP-home visits to qualified AGnES-practice assistants (AGnES: GP-supporting, community-based, e-health-assisted, systemic intervention. Main objectives were the assessment of the acceptance of the AGnES-concept by the participating GPs, patients, and AGnES-practice assistants, the kind of delegated tasks, and the feasibility of home telecare in a GP-practice. Methods In this paper, we report first results of the implementation of this concept in regular GP-practices, conducted November 2005 – March 2007 on the Island of Rügen, Mecklenburg-Western Pomerania, Germany. This study was meant as a proof of concept. The GP delegated routine home-visits to qualified practice employees (here: registered nurses. Eligible patients were provided with telecare-devices to monitor disease-related physiological values. All delegated tasks, modules conducted and questionnaire responses were documented. The participating patients were asked for their acceptance based on standardized questionnaires. The GPs and AGnES-practice assistants were asked for their judgement about different project components, the quality of health care provision and the competences of the AGnES-practice assistants. Results 550 home visits were conducted. 105 patients, two GPs and three AGnES-practice assistants (all registered nurses participated in the project. 48 patients used telecare-devices to monitor health parameters. 87.4% of the patients accepted AGnES-care as comparable to common GP-care. In the course of the project, the GPs delegated an increasing number of both monitoring

  3. Stretchable Materials for Robust Soft Actuators towards Assistive Wearable Devices

    Science.gov (United States)

    Agarwal, Gunjan; Besuchet, Nicolas; Audergon, Basile; Paik, Jamie

    2016-09-01

    Soft actuators made from elastomeric active materials can find widespread potential implementation in a variety of applications ranging from assistive wearable technologies targeted at biomedical rehabilitation or assistance with activities of daily living, bioinspired and biomimetic systems, to gripping and manipulating fragile objects, and adaptable locomotion. In this manuscript, we propose a novel two-component soft actuator design and design tool that produces actuators targeted towards these applications with enhanced mechanical performance and manufacturability. Our numerical models developed using the finite element method can predict the actuator behavior at large mechanical strains to allow efficient design iterations for system optimization. Based on two distinctive actuator prototypes’ (linear and bending actuators) experimental results that include free displacement and blocked-forces, we have validated the efficacy of the numerical models. The presented extensive investigation of mechanical performance for soft actuators with varying geometric parameters demonstrates the practical application of the design tool, and the robustness of the actuator hardware design, towards diverse soft robotic systems for a wide set of assistive wearable technologies, including replicating the motion of several parts of the human body.

  4. Miniature circulatory systems: A new exposure system for ecotoxicological effect assessments in riverine organisms.

    Science.gov (United States)

    Feiner, Mona; Beggel, Sebastian; Geist, Juergen

    2016-11-01

    Long-term effect assessments in ecotoxicological investigations are important, yet there is a lack of suitable exposure systems for these experiments that can be used for riverine species. A cost-efficient miniature circulatory system was developed that was evaluated for its applicability in long-term exposures in 2 stream-dwelling species: brown trout (Salmo trutta) and an amphipod (Gammarus roeseli). In an egg-to-fry exposure of S. trutta, the toxicity of 2 reverse osmosis concentrates was investigated as examples. Control hatching rate of yolk sac fry was 75 ± 7% and thus complies with the Organisation for Economic Co-operation and Development validity criterion (≥66%). The reverse osmosis concentrates did not impair the hatching rate in any tested concentration. In G. roeseli, mortality rates remained below 20% during a 21-d cultivation, fulfilling the common validity criterion in ecotoxicological testing. Mortality was significantly lower when the species was fed with conditioned alder leaves instead of an artificial shrimp food. Finally, a toxicity test on G. roeseli using copper as the test substance revealed median lethal concentration (LC50) values of 156 μg/L after 96 h and 99 μg/L after 264 h, which is in line with literature findings using other accepted exposure units. In conclusion, the miniature circulatory system provides a novel and cost-efficient exposure system for long-term investigations on riverine species that may also be applicable for other species of fishes and macroinvertebrates. Environ Toxicol Chem 2016;35:2827-2833. © 2016 SETAC. © 2016 SETAC.

  5. Annular tidal regenerator engine for nuclear circulatory support systems

    International Nuclear Information System (INIS)

    Hagen, K.G.; Ruggles, A.E.; Fam, S.S.; Torti, V.A.

    1975-01-01

    In order to simplify the configuration of the tidal regenerator engine nuclear-powered circulatory support system, thereby drastically reducing its size and improving the intrinsic reliability, the engine has been redesigned. This redesign focuses on allowing power to be extracted at the low temperature end of the engine utilizing a piston-cylinder arrangement wherein all of the necessary heat transfer processes occur in the annular gap between the piston and cylinder. In all other respects the engine retains its basic characteristics as a hybrid between a Stirling engine and a Rankine engine. A significant advantage of the new arrangement is the ability to raise the superheat temperature limit from 650 0 F to over 900 0 F. This has yielded an increase in engine efficiency from 10 percent to 14 percent, and further increases are anticipated by utilizing an expansion and/or a binary version of the engine. The implantable system volume has been reduced by a factor of three and orientation insensitivity with respect to gravity has been demonstrated. Many system components have already demonstrated endurances of several thousand hours

  6. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.

    Science.gov (United States)

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-12-01

    As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Anesthesia for left ventricular assist device insertion: a case series and review.

    Science.gov (United States)

    Broussard, David; Donaldson, Emilie; Falterman, Jason; Bates, Michael

    2011-01-01

    From October 2008 to June 2010, a total of 42 patients had the HeartMate II left ventricular assist device inserted surgically at Ochsner Medical Center in New Orleans, LA. A retrospective electronic record review was conducted on this series of patients to analyze elements of perioperative anesthetic care, including general anesthetic care, echocardiographic considerations, and blood product usage. Etomidate was used to induce anesthesia for 34 of 42 patients (81%) in this series, with an average dose of 16.5 mg (±6 mg). The average intraoperative fentanyl dose was 1,318 µg (±631 µg). On average, patients were extubated 91 hours (±72 hours) after arrival to the intensive care unit and left on day 9 (±5 days). The average left ventricular ejection fraction of the patients in this series was 13% (±5%). Sixteen patients were evaluated as having severe right-heart dysfunction preoperatively. Two of 42 patients required surgical closure of echocardiographically identified patent foramen ovale. Twelve of 42 patients underwent surgical correction of tricuspid regurgitation. On average, 3 units (±2.6 units) of fresh frozen plasma were transfused intraoperatively and 10 units postoperatively. Intraoperative red blood cell usage averaged 1.1 units (maximum, 7 units), with an average 9.3 units administered in the first 48 hours postoperatively.

  8. Head capsule, chephalic central nervous system and head circulatory system of an aberrant orthopteran, Prosarthria teretrirostris (Caelifera, Hexapoda).

    Science.gov (United States)

    Baum, Eileen; Hertel, Wieland; Beutel, Rolf Georg

    2007-01-01

    The head capsule, the circulatory system and the central nervous system of the head of Prosarthria teretrirostris (Proscopiidae) is described in detail, with special consideration of modifications resulting from the aberrant head shape. The transformations of the head are completely different from those found in phasmatodeans, which are also characterised by twig mimesis. The circulatory system is distinctly modified. A hitherto undescribed additional structure in the posterior head region very likely functions as a pulsatile organ. The cephalic central nervous system is strongly elongated, with changes in the position of the suboesophageal ganglion, the corpora cardiaca and the course of the nervus mandibularis. Three-dimensional reconstructions of these two organ systems in combination with the pharynx were made using Alias Maya 6.0 software. Comparisons with other representatives of Caelifera suggest a clade comprising Proscopiidae and Morabinae. The presence of a transverse muscle connecting the antennal ampullae in Prosarthria shows that this structure likely belongs to the groundplan of Orthoptera, even though it is missing in different representatives of this group. The transverse ampullary muscle is a potential synapomorphy of Orthoptera, Phasmatodea and Dictyoptera.

  9. The human heart and the circulatory system as an interesting interdisciplinary topic in lessons of physics and biology

    International Nuclear Information System (INIS)

    Volná, M; Látal, F; Kubínek, R; Richterek, L

    2014-01-01

    Many topics which are closely related can be found in the national curriculum of the Czech Republic for physics and biology. One of them is the heart and the circulatory system in the human body. This topic was examined cross curriculum, a teaching module was created and the topic was chosen for our research. The task was to determine if the students of bachelor study are aware of connections between physics and biology within this topic and whether we can help them effectively to describe the corresponding physics phenomena in the human body connected, for example, with a heart attack or with the measurement of blood pressure. In this paper, the heart and the circulatory system are presented as suitable topics for an interdisciplinary teaching module which includes both theoretical and experimental parts. The module was evaluated by a group of first-year undergraduate students of physics at the Faculty of Science, Palacký University. The acquired knowledge was compared with another control group through a test. The highest efficiency of the module was evaluated on the basis of questions that covered the calculation problems. (paper)

  10. The effects of aprotinin on blood product transfusion associated with thoracic aortic surgery requiring deep hypothermic circulatory arrest.

    LENUS (Irish Health Repository)

    Seigne, P W

    2012-02-03

    OBJECTIVE: To compare the effects of aprotinin on blood product use and postoperative complications in patients undergoing thoracic aortic surgery requiring deep hypothermic circulatory arrest. DESIGN: A retrospective study. SETTING: A university hospital. PARTICIPANTS: Nineteen patients who underwent elective or urgent thoracic aortic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The total number of units of packed red blood cells, fresh frozen plasma, and platelets was significantly less in the group that received aprotinin (p = 0.01, 0.04, and 0.01). The intraoperative transfusion of packed red blood cells and platelets, collection and retransfusion of cell saver, and postoperative transfusion of fresh frozen plasma were also significantly less in the aprotinin group (p = 0.01, 0.02, 0.01, and 0.05). No patient in either group sustained renal dysfunction or a myocardial infarction. Two patients who had not received aprotinin suffered from chronic postoperative seizures, and one patient who had received aprotinin sustained a perioperative stroke. CONCLUSIONS: Low-dose aprotinin administration significantly decreases blood product transfusion requirements in the setting of thoracic aortic surgery requiring deep hypothermic circulatory arrest, and it does not appear to be associated with renal or myocardial dysfunction.

  11. A Multicenter Study on Long-Term Outcomes After Lung Transplantation Comparing Donation After Circulatory Death and Donation After Brain Death

    NARCIS (Netherlands)

    van Suylen, Vincent; Luijk, B.; Hoek, R A S; van de Graaf, E. A.; Verschuuren, E A; Van De Wauwer, C; Bekkers, J A; Meijer, R C A; van der Bij, W; Erasmus, M E

    2017-01-01

    The implementation of donation after circulatory death category 3 (DCD3) was one of the attempts to reduce the gap between supply and demand of donor lungs. In the Netherlands, the total number of potential lung donors was greatly increased by the availability of DCD3 lungs in addition to the

  12. Designing innovative retractors and devices to facilitate mitral valve repair surgery

    OpenAIRE

    Okamoto, Kazuma; Yozu, Ryohei

    2015-01-01

    Various devices have been developed to facilitate mitral valve surgery, including those that improve mitral valve exposure and assist surgeons with associated procedures. Choosing appropriate supporting devices when performing minimally invasive mitral valve surgery (MIMVS) through a minithoracotomy with endoscopic assistance is critical. Depending on the surgeon’s preference, trans-thoracic or trans-working-port left atrial retractors can be utilized. Although the trans-thoracic retractors p...

  13. Astragalus Extract Mixture HT042 Increases Longitudinal Bone Growth Rate by Upregulating Circulatory IGF-1 in Rats

    Directory of Open Access Journals (Sweden)

    Donghun Lee

    2017-01-01

    Full Text Available Astragalus extract mixture HT042 is a standardized ingredient of health functional food approved by Korean FDA with a claim of “height growth of children.” HT042 stimulates bone growth rate and increases local IGF-1 expression in growth plate of rats which can be considered as direct stimulation of GH and its paracrine/autocrine actions. However, it remains unclear whether HT042 stimulates circulatory IGF-1 which also plays a major role to stimulate bone growth. To determine the effects on circulatory IGF-1, IGF-1 and IGFBP-3 expressions and phosphorylation of JAK2/STAT5 were evaluated in the liver after 10 days of HT042 administration. HT042 upregulated liver IGF-1 and IGFBP-3 mRNA expression, IGF-1 protein expression, and phosphorylation of JAK2/STAT5. HT042 also increased bone growth rate and proliferative zonal height in growth plate. In conclusion, HT042 stimulates bone growth rate via increment of proliferative rate by upregulation of liver IGF-1 and IGFBP-3 mRNA followed by IGF-1 protein expression through phosphorylation of JAK2/STAT5, which can be regarded as normal functioning of GH-dependent endocrine pathway.

  14. Evaluation of cerebro-circulatory metabolic conditions and prognosis in hypertensive putaminal hemorrhage by 31P-MRS

    International Nuclear Information System (INIS)

    Deguchi, Itaru

    2000-01-01

    Phosphorus-31 nuclear magnetic resonance spectroscopy ( 31 P-MRS) provides a non-invasive means to obtain metabolic information. We studied cerebro-circulatory metabolic conditions in the subacute phase of hypertensive putaminal hemorrhage with 31 P-MRS and N-isopropyl-I-(123)-p-Iodoamphetamine single photon emission computed tomography ( 123 I-IMP SPECT). The subjects consisted of 33 cases of hypertensive putaminal hemorrhage. Upon evaluation of cerebral blood flow (CBF) around the ipsilateral frontal lobe cortex and examination by 123 I-IMP SPECT, they would broadly divided into the following three groups: (A) a group with high uptake on both the early image and delayed image, (B) a group with low uptake on the early image but with good redistribution, and (C) a group with low uptake on both images. In these groups 31 P-MRS in the ipsilateral frontal lobe cortex was measured for comparative analysis. In group A, the PCr/Pi ratio was 3.12±0.14 as opposed to 2.87±0.13 in group B, and the ratio was extremely depressed in group C, 1.96±0.16. These observations implied that a high level circulatory metabolic disorder was present in group C and that local viability or metabolic activity was relatively well maintained despite the low perfusion in group B with a satisfactory prognosis being expected due to their high functional level. (author)

  15. Human Grasp Assist Device With Exoskeleton

    Science.gov (United States)

    Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Bridgwater, Lyndon B. J. (Inventor)

    2014-01-01

    A grasp assist system includes a glove, actuator assembly, and controller. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. Phalange rings are positioned with respect to the digit. A flexible tendon is connected at one end to one of the rings and is routed through the remaining rings. An exoskeleton positioned with respect to the digit includes hinged interconnecting members each connected to a corresponding ring, and/or a single piece of slotted material. The actuator assembly is connected to another end of the tendon. The controller calculates a tensile force in response to the measured grasping force, and commands the tensile force from the actuator assembly to thereby pull on the tendon. The exoskeleton offloads some of the tensile force from the operator's finger to the glove.

  16. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    International Nuclear Information System (INIS)

    Li, Nannan; Pang, Shucai; Yan, Fei; Chen, Lei; Jin, Dazhi; Xiang, Wei; Zhang, De; Zeng, Baoqing

    2015-01-01

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided a new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics

  17. U arm type x-ray radiograph system for circulatory system

    International Nuclear Information System (INIS)

    Kiuchi, Shigeo; Kaga, Yuji; Sato, Masami; Komatsuda, Yasushi; Nishio, Kosaku.

    1979-01-01

    This report is concerned with the function and usefulness of U arm type X-ray radiograph system for circulatory system jointly developed by Yamagata University and Toshiba Medical Co., Ltd. The system was used 560 times in 2 years mostly for cinephotography. It has such features as follows: (1) The compound oblique position radiography mechanism of U arm is useful for the separative radiography around coronary artery. (2) The mechanism of U arm is very quick in photographing with fluoroscopy. (3) Very sharp II indirect biplane photographs without obscurity due to enlarging can be taken. (4) An operator can position objects readily by operating a sterilizing switch. (5) Both short time photographing of 1 m sec and high speed repeated photographing of 12 times/sec can be made with the photo timer. (6) The fog due to mutual scattering in RSC biplane photographing can be removed by II blanking method. (Kobatake, H.)

  18. An absorbing microwave micro-solid-phase extraction device used in non-polar solvent microwave-assisted extraction for the determination of organophosphorus pesticides

    International Nuclear Information System (INIS)

    Wang Ziming; Zhao Xin; Xu Xu; Wu Lijie; Su Rui; Zhao Yajing; Jiang Chengfei; Zhang Hanqi; Ma Qiang; Lu Chunmei; Dong Deming

    2013-01-01

    Highlights: ► An absorbing microwave μ-SPE device packed with activated carbon was used. ► Absorbing microwave μ-SPE device was made and used to enrich the analytes. ► Absorbing microwave μ-SPE device was made and used to heat samples directly. ► MAE-μ-SPE was applied to the extraction of OPPs with non-polar solvent only. - Abstract: A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 °C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC–MS without any clean-up process. The recoveries were in the range of 93.5–104.6%, and the relative standard deviations were lower than 8.7%.

  19. Status of the Tidal Regenerator Engine for nuclear circulatory support systems

    International Nuclear Information System (INIS)

    Watelet, R.P.; Ruggles, A.E.; Torti, V.

    1976-01-01

    Based on the annular version of the Tidal Regenerator Engine, a packaged energy system for nuclear powered circulatory support systems was developed. Net power output of approximately 3 watts is delivered using a 33-watt heat source for an engine module volume of 0.7 liter and a weight of 1.6 kg. A higher efficiency dual cycle version of the annular engine using a Dowtherm A topping cycle on the basic steam cycle is also under development. Projected system output using this advanced engine is 5 watts for the same sized heat source. Life testing of critical components has demonstrated substantial reliability improvement over earlier designs. Of particular significance is the continuing operation of a complete implantable engine system after 1200 hours. Component life testing is continuing with over five thousand hours accumulated on two pump actuators employing welded metal bellows

  20. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Directory of Open Access Journals (Sweden)

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.