WorldWideScience

Sample records for cine radiographic experiment

  1. Cine MR imaging before and after realignment surgery for patellar maltracking - comparison with axial radiographs

    International Nuclear Information System (INIS)

    Brossmann, J.; Muhle, C.; Buell, C.C.; Zieplies, J.; Melchert, U.H.; Brinkmann, G.; Schroeder, C.; Heller, M.

    1995-01-01

    Comparison of motion-triggered cine magnetic resonance (MR) imaging and conventional radiographs for the assessment of operative results of patellar realignment. Fifteen patients with recurrent patellar dislocation or patellar subluxation were evaluated with conventional axial radiographs before and after realignment surgery by measuring the congruence angle (CA), lateral patellofemoral angle (LPFA), and lateral displacement (d). In eight patients the patellofemoral joint was additionally evaluated pre- and postoperatively with motion-triggered cine MR imaging by determining the bisect offset (BSO), lateral patellar displacement (LPD), and patellar tilt angle (PTA). Significant differences between the pre- and postoperative measurements were found for all MR imaging parameters (BSO, LPD, PTA: p<0.01) but not for the conventional X-ray parameters (CA: p=0.70, LPFA: p=0.56; d: p=0.04). Motion-triggered cine MR imaging was superior to conventional tangential radiographs for assessing the effectiveness of patellar realignment surgery. (orig.)

  2. Cine MR imaging before and after realignment surgery for patellar maltracking - comparison with axial radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Brossmann, J. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany); Muhle, C. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany); Buell, C.C. [Rheumaklinik, Bad Bramstedt (Germany); Zieplies, J. [Lubinus Klinik, Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany); Brinkmann, G. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany); Schroeder, C. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik der Univ. Kiel (Germany)

    1995-04-01

    Comparison of motion-triggered cine magnetic resonance (MR) imaging and conventional radiographs for the assessment of operative results of patellar realignment. Fifteen patients with recurrent patellar dislocation or patellar subluxation were evaluated with conventional axial radiographs before and after realignment surgery by measuring the congruence angle (CA), lateral patellofemoral angle (LPFA), and lateral displacement (d). In eight patients the patellofemoral joint was additionally evaluated pre- and postoperatively with motion-triggered cine MR imaging by determining the bisect offset (BSO), lateral patellar displacement (LPD), and patellar tilt angle (PTA). Significant differences between the pre- and postoperative measurements were found for all MR imaging parameters (BSO, LPD, PTA: p<0.01) but not for the conventional X-ray parameters (CA: p=0.70, LPFA: p=0.56; d: p=0.04). Motion-triggered cine MR imaging was superior to conventional tangential radiographs for assessing the effectiveness of patellar realignment surgery. (orig.)

  3. Motion-Corrected Real-Time Cine Magnetic Resonance Imaging of the Heart: Initial Clinical Experience.

    Science.gov (United States)

    Rahsepar, Amir Ali; Saybasili, Haris; Ghasemiesfe, Ahmadreza; Dolan, Ryan S; Shehata, Monda L; Botelho, Marcos P; Markl, Michael; Spottiswoode, Bruce; Collins, Jeremy D; Carr, James C

    2018-01-01

    Free-breathing real-time (RT) imaging can be used in patients with difficulty in breath-holding; however, RT cine imaging typically experiences poor image quality compared with segmented cine imaging because of low resolution. Here, we validate a novel unsupervised motion-corrected (MOCO) reconstruction technique for free-breathing RT cardiac images, called MOCO-RT. Motion-corrected RT uses elastic image registration to generate a single heartbeat of high-quality data from a free-breathing RT acquisition. Segmented balanced steady-state free precession (bSSFP) cine images and free-breathing RT images (Cartesian, TGRAPPA factor 4) were acquired with the same spatial/temporal resolution in 40 patients using clinical 1.5 T magnetic resonance scanners. The respiratory cycle was estimated using the reconstructed RT images, and nonrigid unsupervised motion correction was applied to eliminate breathing motion. Conventional segmented RT and MOCO-RT single-heartbeat cine images were analyzed to evaluate left ventricular (LV) function and volume measurements. Two radiologists scored images for overall image quality, artifact, noise, and wall motion abnormalities. Intraclass correlation coefficient was used to assess the reliability of MOCO-RT measurement. Intraclass correlation coefficient showed excellent reliability (intraclass correlation coefficient ≥ 0.95) of MOCO-RT with segmented cine in measuring LV function, mass, and volume. Comparison of the qualitative ratings indicated comparable image quality for MOCO-RT (4.80 ± 0.35) with segmented cine (4.45 ± 0.88, P = 0.215) and significantly higher than conventional RT techniques (3.51 ± 0.41, P cine (1.51 ± 0.90, P = 0.088 and 1.23 ± 0.45, P = 0.182) were not different. Wall motion abnormality ratings were comparable among different techniques (P = 0.96). The MOCO-RT technique can be used to process conventional free-breathing RT cine images and provides comparable quantitative assessment of LV function and volume

  4. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  5. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  6. Visions of normality? Early experiences of radiographic reporting

    Energy Technology Data Exchange (ETDEWEB)

    Reeves, Pauline E-mail: pauline.reeves@whnt.nhs.uk

    2004-08-01

    This article reflects on my early [student] experiences in learning to undertake radiographic reporting and uses critical incidents to highlight two areas of error during this period. These errors include perceptual (optical illusions and, in particular, the Mach band effect) and lack of subject specific knowledge (specifically anatomical knowledge--especially of normal anatomical variants). These two errors are analysed in the wider context of radiological error and the difficulty in reaching consensus even between experienced reporters.

  7. Visions of normality? Early experiences of radiographic reporting

    International Nuclear Information System (INIS)

    Reeves, Pauline

    2004-01-01

    This article reflects on my early [student] experiences in learning to undertake radiographic reporting and uses critical incidents to highlight two areas of error during this period. These errors include perceptual (optical illusions and, in particular, the Mach band effect) and lack of subject specific knowledge (specifically anatomical knowledge--especially of normal anatomical variants). These two errors are analysed in the wider context of radiological error and the difficulty in reaching consensus even between experienced reporters

  8. Workplace experience of radiographers: impact of structural and interpersonal interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kubik-Huch, R.A.; Roempler, M.; Weber, A. [Kantonsspital Baden, Institute of Radiology, Baden (Switzerland); Klaghofer, R.; Buddeberg-Fischer, B. [Zurich University Hospital, Department of Psychosocial Medicine, Zurich (Switzerland)

    2010-02-15

    Within the framework of organisational development, an assessment of the workplace experience of radiographers (RGs) was conducted. The aims of this study were to develop structural and interpersonal interventions and to prove their effectiveness and feasibility. A questionnaire consisting of work-related factors, e.g. time management and communication, and two validated instruments (Workplace Analysis Questionnaire, Effort-Reward Imbalance Scale) was distributed to all RGs (n = 33) at baseline (T1). Interventions were implemented and a follow-up survey (T2) was performed 18 months after the initial assessment. At T1, areas with highest dissatisfaction were communication and time management for ambulant patients (bad/very bad, 57% each). The interventions addressed adaptation of work plans, coaching in developing interpersonal and team leadership skills, and regular team meetings. The follow-up survey (T2) showed significantly improved communication and cooperation within the team and improved qualification opportunities, whereas no significant changes could be identified in time management and in the workplace-related scales 'effort' expended at work and 'reward' received in return for the effort. Motivating workplace experience is important for high-level service quality and for attracting well-qualified radiographers to work at a place and to stay in the team for a longer period. (orig.)

  9. Workplace experience of radiographers: impact of structural and interpersonal interventions

    International Nuclear Information System (INIS)

    Kubik-Huch, R.A.; Roempler, M.; Weber, A.; Klaghofer, R.; Buddeberg-Fischer, B.

    2010-01-01

    Within the framework of organisational development, an assessment of the workplace experience of radiographers (RGs) was conducted. The aims of this study were to develop structural and interpersonal interventions and to prove their effectiveness and feasibility. A questionnaire consisting of work-related factors, e.g. time management and communication, and two validated instruments (Workplace Analysis Questionnaire, Effort-Reward Imbalance Scale) was distributed to all RGs (n = 33) at baseline (T1). Interventions were implemented and a follow-up survey (T2) was performed 18 months after the initial assessment. At T1, areas with highest dissatisfaction were communication and time management for ambulant patients (bad/very bad, 57% each). The interventions addressed adaptation of work plans, coaching in developing interpersonal and team leadership skills, and regular team meetings. The follow-up survey (T2) showed significantly improved communication and cooperation within the team and improved qualification opportunities, whereas no significant changes could be identified in time management and in the workplace-related scales 'effort' expended at work and 'reward' received in return for the effort. Motivating workplace experience is important for high-level service quality and for attracting well-qualified radiographers to work at a place and to stay in the team for a longer period. (orig.)

  10. The role of the consultant radiographer - Experience of appointees

    International Nuclear Information System (INIS)

    Ford, Peter

    2010-01-01

    Aim: To explore the experience of the first consultant practitioners appointed; including the appointment process, nature of the role, their perceptions of success and challenges. Method: This was a whole population study of the known consultant radiographers appointed up to March 2005. It consisted of 3 phases. The first compared appointees job descriptions with the Department of Health guidance, the second collected contextual information using a questionnaire, and the third explored postholders experiences using telephone interviews. Results: Ten of the possible twelve appointees participated. All posts were established according to the guidelines, with largely similar job descriptions allowing for the different clinical specialist areas. All were very positive in their perceptions of their role, and faced similar challenges. They were strongest in their expert clinical practice working but had strong training and leadership roles. The number working at strategic level was low with limited research and few published papers, although there were notable exceptions. Conclusions: The first appointees demonstrated notable successes, strongest in the expert clinical practice element of roles, with evidence of team leadership, and involvement in training and education. Strategic engagement was disappointing, with little research being undertaken. Their experience was that the nature of consultancy was poorly understood by peers and medical colleagues.

  11. Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T.

    Science.gov (United States)

    Okuda, Shigeo; Yamada, Yoshitake; Tanimoto, Akihiro; Fujita, Jun; Sano, Motoaki; Fukuda, Keiichi; Kuribayashi, Sachio; Jinzaki, Masahiro; Nozaki, Atsushi; Lai, Peng

    2015-09-01

    Three-dimensional cardiac cine imaging has demonstrated promising clinical 1.5-Tesla results; however, its application to 3T scanners has been limited because of the higher sensitivity to off-resonance artifacts. The aim of this study was to apply 3D cardiac cine imaging during a single breath hold in clinical patients on a 3T scanner using the kat ARC (k- and adaptive-t auto-calibrating reconstruction for Cartesian sampling) technique and to evaluate the interchangeability between 2D and 3D cine imaging for cardiac functional analysis and detection of abnormalities in regional wall motion. Following institutional review board approval, we obtained 2D cine images with an acceleration factor of two during multiple breath holds and 3D cine images with a net scan acceleration factor of 7.7 during a single breath hold in 20 patients using a 3T unit. Two readers independently evaluated the wall motion of the left ventricle (LV) using a 5-point scale, and the consistency in the detection of regional wall motion abnormality between 2D and 3D cine was analyzed by Cohen's kappa test. The LV volume was calculated at end-diastole and end-systole (LVEDV, LVESV); the ejection fraction (LVEF) and myocardial weight (LVmass) were also calculated. The relationship between functional parameters calculated for 2D and 3D cine images was analyzed using Pearson's correlation analysis. The bias and 95% limit of agreement (LA) were calculated using Bland-Altman plots. In addition, a qualitative evaluation of image quality was performed with regard to the myocardium-blood contrast, noise level and boundary definition. Despite slight degradation in image quality for 3D cine, excellent agreement was obtained for the detection of wall motion abnormalities between 2D and 3D cine images (κ=0.84 and 0.94 for each reader). Excellent correlations between the two imaging methods were shown for the evaluation of functional parameters (r>0.97). Slight differences in LVEDV, LVESV, LVEF and LVmass

  12. Children’s experience of going through an acute radiographic examination

    International Nuclear Information System (INIS)

    Björkman, B.; Almqvist, L.; Sigstedt, B.; Enskär, K.

    2012-01-01

    Children’s experience of radiographic examinations remains largely unexplored, although most radiographers examine children on a daily basis. In order to provide the high quality care that meets the needs of patients it was considered important to undertake research focused upon the patients’ experience of radiographic practice. The aim of the study was to investigate children’s experiences undergoing a radiographic examination for a suspected fracture. Inclusion criteria were Swedish-speaking children between 3 and 15 years of age who were submitted for a radiographic examination with an acute condition of the upper or lower extremity. Patients were informed of the study and together with the escorting parent or relative asked for consent to participate. During the examination the child was videotaped and immediately after, the child was interviewed in a nearby facility. The interview contained open-ended questions and was conducted while watching the videotape together with the child and their parent or relative and the researcher. Qualitative content analysis was used in analyzing the collected data. The analysis resulted in two categories – “feeling uncomfortable” and “feeling confident”. The subcategories contained in these categories were “pain in relation to injury and examination”, “the waiting time is strenuous”, “worries for the future and consequences of the injury”, “confidence in parental presence”, “confidence in radiographic staff and examination procedure”, and finally “recognition entails familiarity”. The results revealed that for the younger children, the experience of undergoing an acute radiographic examination was associated with pain and anxiety, but for the older children, the anxiety was more connected to whether the injury had caused a fracture and any anticipated future consequences or complications.

  13. Exploring the research domain of consultant practice: Experiences of consultant radiographers

    International Nuclear Information System (INIS)

    Harris, R.; Paterson, A.

    2016-01-01

    Aim: This paper reports on one part of a larger study. The aim of the overall study was to explore what the core domain of research means to consultant radiographers in clinical practice and to identify the key factors that facilitate or hinder research activity by this staff group. Design and method: Grounded theory research methodology was employed. This second part of the study involved telephone interviews with twenty five consultant radiographers. Results: Results indicate there are variations across clinical specialties as to the amount and level of research undertaken by consultant radiographers. The principal barriers revealed were: lack of time; excessive clinical workload; lack of skills and confidence to undertake research; poor research culture; and lack of support. The main facilitators noted were: dedicated time, research training and up-skilling; mutually beneficial collaborations; managerial understanding of the research domain of the role; and research focussed on clinical demand. Conclusion: Fulfilling the clinical role is imperative and integral to the profession at consultant level; however, if it is undertaken to the detriment of the other domains then these practitioners may not be operating at ‘consultant’ level. Overall improvements must be made to ensure that the consultant radiographer role is delivering on current expectations and is safeguarded for the future of the next generation of radiographers. - Highlights: • Consultant radiographers undertake research but have concerns about their research skills. • Research aims to improve practice and patients' experiences. • Relatively few consultant radiographers publish their work regularly. • Consultant radiographers allocate little protected time for research due to clinical demands.

  14. CINE CLUB

    CERN Multimedia

    Ciné Club

    2009-01-01

    Main Auditorium CERN jeudi 17 décembre 2009 à 18 h 15 à l’Amphithéâtre principal du CERN (bâtiment 500)   Comme chaque année avant Noël, le CineClub du CERN est heureux d’inviter petits et grands à une projection gratuite du film   LE MONDE DE NEMO (FINDING NEMO) (USA, 2003, Andrew Stanton and Lee Unkrich)   Dans les eaux tropicales de la Grande Barrière de corail, un poisson-clown du nom de Marin mène une existence paisible avec son fils unique, Nemo. Redoutant l’océan et ses risques imprévisibles, il fait de son mieux pour protéger son fils. Comme tous les petits poissons de son âge, celui-ci rêve pourtant d’explorer les mystérieux récifs. Lorsque Nemo disparaît, Marin devient malgré lui le héros d’une qu&a...

  15. Cine club

    CERN Document Server

    Ciné club

    2010-01-01

    Monday 13 December 2010 at 18:30 / Lundi 13 Décembre 2010 à 18:30 CERN Main Auditorium / Amphithéâtre Principal Comme chaque année avant Noël, le CINE-CLUB du CERN est heureux d’inviter petits et grands à une projection gratuite du film.   Ponyo sur la falaise (Japon, 2008, Hayao Miyazaki) Le petit Sosuke vit avec sa mère sur une haute falaise surplombant la mer. Un beau jour, il découvre sur la plage caillouteuse Ponyo, une petite fille poisson. Ponyo est si fascinée par Sosuke et le monde terrestre que son désir le plus cher est de devenir un être humain. Mais Fujimoto, son magicien de père, n’est pas du tout d’accord avec cette idée et il la force à regagner les profondeurs de l’océan. Bien décidée à revoir Sosuke, Ponyo s’&...

  16. Prototype radiographic system for emergency and intensive care units: Initial experience

    International Nuclear Information System (INIS)

    Mirvis, S.

    1986-01-01

    A prototype radiographic system has been developed for use in bedside examinations in multibed trauma or intensive care units and emergency rooms. The system features a single-phase, high-frequency 30-kW ceiling-mounted generator with an x-ray tube extending from a long counterbalanced arm. All movements are servo-assisted for ease of operation. Based on initial experience, the unit allows easier access to the patient around resuscitation and monitoring equipment, occupies less floor space, and yields better quality images than do standard mobile radiographic units

  17. Enhancing the learning experience of student radiographers with dyslexia

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Irene [Cranfield University, Centre for Radiographic and Medical Studies, RMCS, Shrivenham, Swindon, SN6 8LA (United Kingdom)], E-mail: irene.foster@uwe.ac.uk

    2008-02-15

    Widening participation policies and increased awareness of dyslexia has resulted in a marked increase in the numbers of students with dyslexia being identified in higher education in recent years. This study was conducted to not only gain a greater understanding of teaching and learning strategies, but also provide opportunities for improved learning experiences and achievement of students who do not respond well to written forms of assessment. Although a small scale study, the outcomes demonstrate a useful pilot for future scrutiny and basis for further study.

  18. Digital cine-imaging

    International Nuclear Information System (INIS)

    Masuda, Kazuhiro

    1992-01-01

    Digitization of fluoroscopic images has been developed for the digital cine imaging system as a result of the computer technology, television technology, and popularization of interventional radiology. Present digital cine imaging system is able to offer images similar to cine film because of the higher operatability and better image quality with the development of interventional radiology. As a result, its higher usefulness for catheter diagnosis examination except for interventional radiology was reported, and the possibility of having filmless cine is close to becoming a reality. However several problems have been pointed out, such as spatial resolution, time resolution, storage and exchangeability of data, disconsolidated viewing functions, etc. Anyhow, digital cine imaging system has some unresolved points and lots the needs to be discussed. The tendency of digitization is the passage of the time and we have to promote a study for more useful digital cine imaging system in team medical treatment which centers on the patients. (author)

  19. Radiographic diagnosis of proximal caries-influence of experience and gender of the dental staff.

    Science.gov (United States)

    Geibel, Margrit-Ann; Carstens, S; Braisch, U; Rahman, A; Herz, M; Jablonski-Momeni, A

    2017-12-01

    The aim of this study was to examine the influence of experience and gender on the radiographic detection of proximal caries lesions and on therapeutic decisions. A survey of 220 examiners (students and employees at three universities and dentists in the field) was taken using a standardized written questionnaire concerning radiographic diagnosis and therapy planning. An expert opinion of four dentists was determined as radiographic reference. A mixed effect logistic regression model was used for statistical evaluation and the odds ratio and p values were calculated (α = 0.05). Examiners with experience had an almost four times greater chance of a correct assessment, if proximal caries lesion was present or not, than examiners with low experience (OR 3.7 (95% CI 2.4-5.8)). No gender-specific differences were discovered (OR women vs. men 0.9 (95% CI 0.6-1.4)). There was a relationship between the severity of the burnout effect on the x-ray and false positive caries diagnosis. Overall, 43% of respondents would plan invasive treatment in the enamel on a patient at low risk of caries and 78% on a high-risk patient. The results showed that the more experienced practitioners would be more likely to postpone restorative therapy on proximal caries until the lesion reached a later stage. The results of this study suggest that examiner's experience influences the radiographic diagnosis of proximal lesions. No gender-specific differences could be found. Examiner's professional experience is an important factor when radiography is included for detection and treatment planning of proximal lesions.

  20. Implementing radiographic CT head reporting: The experiences of students and managers

    International Nuclear Information System (INIS)

    Clarke, Ruth; Allen, David; Arnold, Paul; Snaith, Beverley

    2014-01-01

    Introduction: In the face of growing demand in radiology, skill mix initiatives have sought to improve and expand service provision. Within the UK radiographer reporting is now widespread, although the growth in computerised tomography (CT) head reporting has not been as rapid as anticipated. The literature in this area is limited, but case studies have highlighted the successful implementation of this training through new radiographer roles in practice. Method: A cross-sectional survey was developed to elicit information from radiographers and managers on their experiences before, during and after post-graduate training in CT head reporting. Results: Seventy one responses were received comprising 48 past students (n = 48/111; 43.2%) and 23 service managers (n = 23/67; 34.3%). Key factors for the development were personal continual professional development for students and departmental need for managers. Challenges during training included a lack of study time due to staff shortages and access to radiologist mentors. Only 48.8% of students responding have gone on to use the new skills in practice cited reasons include staff shortages, resistance from radiologists and increase in radiological staffing. Conclusions: This qualitative study has demonstrated that those trusts who have implemented CT head reporting have evidenced perceptible benefits for both the department and individuals. Those radiographers who are successfully reporting have shown themselves to be highly motivated and persistent in their development

  1. System For The Digitization, Display And Archiving Of Radiographs: Design And Early Experience

    Science.gov (United States)

    Jennings, R. J.; Bruce, M. C.

    1985-06-01

    In this paper we describe a system for the digitization, display, and storage of radiographic images. The system was set up to support a project to assess the clinical impact of matrix size on teleradiology, defined for our purposes as the electronic recording and transmission of radiographs. The system consists of two separate facilities, one for image digitizing and the other for image display, interpretation, and archiving. The image digitizing laboratory uses a solid state scanner interfaced to a dedicated, general-purpose minicomputer. The display facility consists of a general-purpose, multi-user minicomputer with large main memory and disk capacity and a 1280 by 1024 display subsystem with three separate image memories. The two facilities communicate via magnetic tape. This paper documents the characterization of the image data base used for the project, the design and operational features of the two facilities, technical problems encountered in the digitizing and display of radiographs, and some logistical and managerial considerations involved in generating and maintaining a large digital image archive. Since many of the functions of the system we have set up are common to picture archiving and communication systems, we have, where possible, compared the performance of the system we have developed with the requirements that would have to be satisfied by a system intended for clinical use. We leave for future reports the discussion of the conduct of the image reading experiments and the results of those experiments.

  2. Música y Cine

    OpenAIRE

    Olarte Martínez, Matilde María

    2008-01-01

    Materiales de clase: Introducción a la Historia de la Música en el Cine; partituras de cine mudo; música clásica y cine; textos sobre música incidental. Se Analiza la música utilizada en cinematografía, y el estudio de sus funciones aplicada a la imagen. Audiciones de música incidental y música preexistente de los principales compositores. la música utilizada en cinematografía, y el estudio de sus funciones aplicada a la imagen. Audiciones de música incidental y música preexistente de los ...

  3. Cine club

    CERN Multimedia

    Cine Club

    2016-01-01

    Wednesday 1st June 2016 at 20:00 CERN Council Chamber The Dark Glow of the Mountains Directed by Werner Herzog Germany, 1985, 45 minutes Werner Herzog follows mountaineers Hans Kammerlander and Reinhold Messner during their expedition into climbing the Gasherbrum mountains, which has some of the most difficult peaks to be conquered, and they'll do it without the use of oxygen tanks. Herzog also takes some time to hear about their past experiences with other mountains, their personal tragedies and the reasons why they are so involved with such activity. Original version German; English subtitles   The Challenge Directed by Milton Rosmer, Luis Trenker UK, 1938, 76 minutes In 1865, the unconquered Matterhorn beckons; former rivals, Italian Carrel and Englishman Whymper, hope to climb it together, but national rivalry intervenes. Rival parties dangerously race for the summit in realistic, well-photographed climbing scenes; but when the mountain is climbed, the danger is far from over.... Origina...

  4. Cine club

    CERN Multimedia

    Cine club

    2016-01-01

    Wednesday 5 October 2016 at 20:00 CERN Council Chamber Love.net   Directed by VIlian Djevelekov Bulgaria, 2011, 109 minutes The film follows the parallel stories of a number of characters who are trying to change their lives via the Internet or are simply having fun online. Original version Bulgarian; English subtitles Wednesday 12 October 2016 at 20:00 CERN Council Chamber Living Legends   Directed by Niki Iliev Bulgaria, 2014, 110 minutes A group of friends meet again, thirteen years after their prom because of a problem of one of them, and face the opportunity to experience the things in life they have always put aside so far. Original version Bulgarian; English subtitles

  5. Cine club

    CERN Multimedia

    Cine club

    2015-01-01

    Wednesday 24 June 2015 at 20:00 CERN Council Chamber Habemus Papam Directed by Nanni Moretti Italy / France, 2011, 102 minutes   At the Vatican, following the demise of the Pope, the conclave electing his successor settles on Cardinal Melville. But the faithful gathered in St Peter's Square wait in vain for the new Pope to step out on the balcony. What is going on? Behind the thick walls of the Vatican panic has set in. After uttering a terrible howl of fear, the Cardinal refuses the office. The officials do everything to try to reason with Melville, including a psychoanalyst, appointed by the Vatican... Do we really have a Pope? Original version Italian; English subtitles   Wednesday 1st July 2015 at 20:00 CERN Council Chamber Léa An angel in my house Directed by Jacques-Hervé Fichet France, 2014, 100 minutes   A ruthless scientist, Cal Zimmerman, is being interrogated about an experiment that he performed two years ago. During the sa...

  6. Cine club

    CERN Multimedia

    Cine club

    2016-01-01

    Wednesday 19 October 2016 at 20:00 CERN Council Chamber Yesterday   Directed by Ivan Andonov Bulgaria, 1988, 84 minutes Back into the 60s. While out there, in the West, they are listening to The Beatles and The Rolling Stones, the hippie movement is at its height, pupils in Bulgaria are obliged to be shingled, to wear full-dress uniforms and sing military songs. But for how long? A group of pupils from a language school believe they have to live differently. They are seeking for ways to shake off everything phony, to be candid with each other, to be part of a wider, much more interesting world. Some of them pay a high price, others experience cruel worldly lessons, but they at least make their best to save face. Original version Bulgarian; English subtitles Wednesday 26 October 2016 at 20:00 CERN Council Chamber Doomed Souls   Directed by Vulo Radev Bulgaria, 1975, 141 minutes The events of the film are related to the Civil War in Spain. This is a film about the beauty of love - exotic an...

  7. Cine club

    CERN Multimedia

    Ciné club

    2015-01-01

    Wednesday 15 April 2015 at 20:00CERN Council Chamber The Cat o’ Nine Tails (Il gatto a nove code) Directed by Dario Argento (Italy, 1971) 112 minutes   Franco Arno is a blind man that lives with his young niece and makes a living writing crossword puzzles. One night, while walking on the street, he overhears a weird conversation between two men sitting in a car parked in front of a medical institute where genetic experiments are performed. The same night someone breaks in the institute and knocks out a guard. Arno decides to investigate with the help of reporter Carlo Giordani. Original version Italian; English subtitles   Wednesday 22 April 2015 at 20:00CERN Council Chamber Four Flies on Grey Velvet (4 mosche di velluto grigio) Directed by Dario Argento (Italy, 1971) 104 minutes Roberto, a drummer in a rock band, keeps receiving weird phone calls and being followed by a mysterious man. One night he manages to catch up with his persecutor and tries to get him to t...

  8. Cine MRI: a new approach to the diagnosis of scapholunate dissociation.

    Science.gov (United States)

    Langner, I; Fischer, S; Eisenschenk, A; Langner, S

    2015-08-01

    To evaluate the feasibility of cine MRI for the detection of scapholunate dissociation (SLD) and to compare the sensitivity and specificity of cine MRI with those of cineradiography and arthroscopy. To evaluate feasibility, healthy subjects underwent cine MRI of the wrist. To evaluate sensitivity and specificity, patients with clinically suspected scapholunate ligament (SLL) injury after trauma to the wrist were prospectively included and underwent radiographic examination, cineradiography, and cine MRI. In 25 out of 38 patients, subsequent arthroscopy was performed. Results of cineradiography and cine MRI correlated with those of arthroscopy. Cine MRI was of diagnostic quality in all healthy subjects and patients with good interrater agreement. There was excellent correlation between cineradiography and cine MRI. Scapholunate distance differed significantly between healthy subjects and patients with scapholunate dissociation (p Cine MRI had 85% sensitivity and 90% specificity for the detection of SLD. Cine MRI of the wrist is a fast and reliable technique for the detection of SLD with diagnostic accuracy comparable to cineradiography. It can be easily implemented as a routine clinical MRI examination, facilitating diagnostic workup of patients with suspected SLD while avoiding radiation exposure.

  9. Cine MRI: a new approach to the diagnosis of scapholunate dissociation

    Energy Technology Data Exchange (ETDEWEB)

    Langner, I.; Eisenschenk, A. [University Medicine Greifswald, Division of Hand Surgery and Functional Microsurgery, Department of Trauma and Reconstructive Surgery, Greifswald (Germany); Fischer, S.; Langner, S. [University Medicine Greifswald, Institute for Diagnostic Radiology and Neuroradiology, Greifswald (Germany)

    2015-08-15

    To evaluate the feasibility of cine MRI for the detection of scapholunate dissociation (SLD) and to compare the sensitivity and specificity of cine MRI with those of cineradiography and arthroscopy. To evaluate feasibility, healthy subjects underwent cine MRI of the wrist. To evaluate sensitivity and specificity, patients with clinically suspected scapholunate ligament (SLL) injury after trauma to the wrist were prospectively included and underwent radiographic examination, cineradiography, and cine MRI. In 25 out of 38 patients, subsequent arthroscopy was performed. Results of cineradiography and cine MRI correlated with those of arthroscopy. Cine MRI was of diagnostic quality in all healthy subjects and patients with good interrater agreement. There was excellent correlation between cineradiography and cine MRI. Scapholunate distance differed significantly between healthy subjects and patients with scapholunate dissociation (p < 0.001), but not between imaging modalities in the patient group. Cine MRI had 85 % sensitivity and 90 % specificity for the detection of SLD. Cine MRI of the wrist is a fast and reliable technique for the detection of SLD with diagnostic accuracy comparable to cineradiography. It can be easily implemented as a routine clinical MRI examination, facilitating diagnostic workup of patients with suspected SLD while avoiding radiation exposure. (orig.)

  10. Cine MRI of dissecting aneurysm

    International Nuclear Information System (INIS)

    Takaki, Hajime

    1991-01-01

    Cine MRI was performed in 25 cases of aortic dissection and comparative study among cine MRI, spin-echo static MRI, contrast-enhanced CT and intravenous digital subtraction angiography (IVDSA) was made. Cine MRI accurately detected aortic dissection. It was most accurate among various diagnostic methods in demonstration of entry site of dissection. Take-off of renal artery and its relation to true and false channels was also accurately demonstrated by cine MRI. The above results suggest that cine MRI can be an important diagnostic modality with almost equal diagnostic quality to those of conventional angiography. However, further technical improvement to shorten the imaging time seems necessary to replace angiography. (author)

  11. Cine magnetic resonance

    International Nuclear Information System (INIS)

    Higgins, C.B.; Sechtem, U.P.; Pflugfelder, P.

    1987-01-01

    Cine magnetic resonance (MR) is a fast MR imaging process with referencing of the imaging data to the electrocardiogram (ECG) so that images corresponding to 21-msec segments of the cardiac cycle are acquired. A series of such images, each corresponding to a 21-msec segment of the cardiac cycle, can be laced together for viewing in the cine format at a framing rate of 20 to 40 frames per second. Since cine angiograms of the heart are usually done at 30 frames per second, this technique achieves a temporal resolution adequate for the evluation of central cardiovascular function. The major application of this technique is to depict central cardiovascular function and blood flow

  12. Memoria y Cine

    OpenAIRE

    Getino, Octavio

    2006-01-01

    El cine argentino conserva como puntos básicos de referencia las obras de portavoces de la memoria y de la historia popular. Obras no sólo de fecha reciente, sino también aquellas que nacen con la propia industria cinematográfica. Este artículo, cuyas reflexiones –según coincidimos con su autor– conservan vigencia, apareció por primera vez en México, en 1984, en Notas sobre cine argentino y latinoamericano, una publicación que reunió diversos aportes sobre la cinematografía nacional y lati...

  13. El cine posmoderno

    Directory of Open Access Journals (Sweden)

    Edel Cadena Vargas

    2015-05-01

    Full Text Available En el presente trabajo se trata de dar respuesta a las siguientes preguntas: ¿cuál es el origen del cine posmoderno?, ¿cuáles son los factores que permiten su creación?, ¿a qué sentimiento responde?

  14. Metodología de la investigación y cine comercial: claves de una experiencia docente Research methodology and commercial cinema: keys for an educational experience

    Directory of Open Access Journals (Sweden)

    M.T. Icart-Isern

    2008-03-01

    Full Text Available Introducción. El cine se ha configurado, ya desde sus inicios, como una de las recreaciones humanas más extraordinarias que existen desde la perspectiva de la comunicación. Objetivo. El objetivo de este texto es presentar una experiencia docente en la que se empleó cine comercial (CC en el desarrollo de la asignatura optativa ‘Investigación en salud: métodos y técnicas’, que se imparte en la Escuela de Enfermería de la Universitat de Barcelona. Desarrollo. Los contenidos de esta asignatura son los habituales en los cursos de investigación, y lo más interesante fue el empleo del CC, que se convirtió en el material (objeto de estudio. En el transcurso de la asignatura, el alumno debía realizar una serie de actividades: revisión bibliográfica, preparación de un cuestionario, selección y visualización de una película de la que debía elaborar la correspondiente ficha técnica y un informe sobre los aspectos referidos a la enfermedad, el paciente, los profesionales y los valores, sentimientos y emociones asociados al problema de salud. Conclusiones. La experiencia puso de manifiesto la importancia de la observación atenta de las escenas para captar los mensajes no verbales relacionados con el problema de salud; la necesidad de adquirir habilidades para el manejo de las bases de datos bibliográficas (Medline, CINAHL, etc., y la conveniencia de una mayor formación en el lenguaje cinematográfico para un mejor aprovechamiento didáctico del CC.Introduction. The cinema has become from its beginnings, like one of the most extraordinary human recreation that exists from the communication point of view. Aim. The objective of this paper is to present an educational experience in which commercial cinema (CC was used in the development of the optional subject ‘Investigation in health: health research methods and techniques’, which is taught in the Nursing School at the University of Barcelona. Development. The content of the course

  15. Cine y literatura

    Directory of Open Access Journals (Sweden)

    Jorge Enrique Adoum

    2015-01-01

    Full Text Available El lanzamiento de la undécima edición de la novela de Jorge Enrique Adoum "Entre Marx y una mujer desnuda" y el comienzo simultáneo de la filmación de la película basada en esa obra, ha puesto nuevamente de relieve, el recurrente tema de la literatura llevada al cine. En ese sentido, en agosto, se llevó a cabo una mesa redonda en la que participaron como exponentes Camilo Luzuriaga (director del filme, Omar Ospina (crítico cinematográfico y jorge Enrique Adoum. En el siguiente artículo -basado en su exposición en la mesa redonda-, el reconocido escritor analiza cómo debe ser para él la vinculación entre literatura y cine.

  16. Cine e identidades virtuales

    Directory of Open Access Journals (Sweden)

    Labrador Ben, Julia María

    2006-12-01

    Full Text Available The subject is the ability the cinema has performed - since its very begining - as a creation instrument of national and transnational identities. In the first place, it covers Spanish cinema since 1938 and right after the end of the Spanish Civil War, II World War Italian-German cinema, Eisenstein’s, Leni Riefenstahl’s, Griffth’s and Ford’s cinema, the role American war and science fiction productions played, as well as the comedies dealing with the divided Berlin subject. The role of computers and video-games and the new cinema positionings that forecast the end of what is real, is studied through films such as Tron, The Lawnmower Man, Johnny Mnemonic, Ghost in the shell, Simone o Matrix.Se estudia la capacidad del cine desde sus orígenes como instrumento de generación de identidades nacionales y transnacionales. Se realiza, en primer lugar, un recorrido por el cine español desde 1938 y tras el final de la guerra civil, el cine italo-alemán de la II Guerra Mundial, el cine de Eisenstein, Leni Riefenstahl, Griffth y Ford, y el papel que jugaron las producciones norteamericanas bélicas y de ciencia ficción, así como las comedias sobre el Berlín dividido. El papel de los ordenadores y los videojuegos, y los nuevos planteamientos cinematográficos que pronostican el final de lo real se estudia a través de películas como Tron, El cortador de césped, Johnny Mnemonic, Ghost in the shell, Simone o Matrix.

  17. The Cine Club de Lima

    Directory of Open Access Journals (Sweden)

    Ricardo Bedoya

    2009-10-01

    Full Text Available Cine Club de Lima was the most important cinematography culture spreading institution of the fifties. It was also the precursor of other movie clubs of following decades, which would bring together important Peruvian intellectuals from every art form, who would together promote cultural entertainment. This piece describes ”Cine Club Lima” origins and dissolution, while taking into account its programs.

  18. Presentation and analysis of data on radiographic outcome in clinical trials: experience from the TEMPO study

    NARCIS (Netherlands)

    van der Heijde, Désirée; Landewé, Robert; Klareskog, Lars; Rodríguez-Valverde, Vicente; Settas, Lucas; Pedersen, Ronald; Fatenejad, Saeed

    2005-01-01

    To evaluate different methods of presentation and analysis of radiographic data in a rheumatoid arthritis (RA) randomized controlled trial. A double-blind randomized controlled trial including 682 patients with active RA who were treated with methotrexate, etanercept, or a combination of the 2 drugs

  19. CineGlob

    CERN Multimedia

    CineGlob

    2014-01-01

    CERN will be hosting the next CineGlobe International Film Festival from March 18 to 23 at the Globe of Science and Innovation with the theme “Beyond the Frontier”, This 4th edition will see 66 short films “inspired by science” in competition, including fiction films as well as documentaries. From Tuesday the 18th to Friday the 21st, special lunch sessions are organized from 12:30 to 13:30. Food will be available for purchase at the tent “Café Cinéma” next to the Globe. Special evenings While the short film screenings are the heart of the festival, every year CineGlobe also organizes compelling special events every night, from feature films to special musical performances: Tuesday 18th: The Swiss premiere of the acclaimed documentary film Particle Fever. Presented by BBC Storyville with Fabiola Gianotti and director Mark Levinson in attendance; Wednesday 19th: The result of the “Story Matter” Hacka...

  20. Cine-Club

    CERN Multimedia

    Cine-Club

    2013-01-01

    The CERN CineClub is a meeting point every Thursday for anyone who wants to discover, discuss, and appreciate cinema with people who are truly interested in the art of the moving image. In the actual context where downloading became easier than cooking an egg, one might wonder why bother when it can be watched on any computer. Well, cinema is not an individual activity. What the CineClub offers is a big screen with good quality image and sound. It also offers a careful selection, for allowing people to (re-)discover new and forgotten authors. Finally, it offers the opportunity for meeting people sharing a common interest. So come every Thursday, and see by yourself that watching films can actually be a real party! Every Thursday at 20 h 00 Council Chamber, 503/1-001 Programme June 2013 Science Fiction Cycle “Imagination is more important than knowledge. For knowledge is limited, whereas imagination embraces the entire world, stimulating progress, giving birth to evolution.” 6th June 2...

  1. Chest radiographic appearances in adult inpatients admitted with swine flu infection: local experience in Melbourne

    International Nuclear Information System (INIS)

    Pirakalathanan, Janu; Lau, Kenneth K.; Joosten, Simon A.

    2013-01-01

    The influenza A virus (H1N1) pandemic began in Mexico in March 2009. As of July 2009, there were 5298 reported cases in Australia including 10 deaths. The aim of this review is to demonstrate the local chest radiographic findings in adult inpatients with proven H1N1, to assess the radiological disease progression and resolution, and to evaluate whether the severity of chest X-rays findings had a bearing on the length of admission and need for intensive care admission. Eleven H1N1 patients (5 males and 6 females, mean age of 36), presenting with cough (64%), fever (55%) and shortness of breath (55%), were admitted to our hospital between 13 August and 1 November 2010. Details of radiographic features, risk factors, clinical course including length of stay, doubling time of consolidation and time for 50% resolution of consolidation were recorded and analysed. Seventy-three per cent of our patients presented with bilateral mid and/or lower zone alveolar consolidation. One patient with underlying cystic fibrosis had only bilateral upper zone consolidation. No pleural effusion, lymphadenopathy or cardiomegaly was noted on any of the plain chest radiographs. The mean doubling time of consolidation was 1.5 days. The mean time for 50% resolution of consolidation after antiviral treatment was 10.5 days. The average length of stay in hospital was 22 days. Ninety-one per cent of our patients required intensive-care unit admission with 50% of those requiring intubation. Rapid progression of bilateral mid and lower zone air-space opacities in relatively young unwell patients, with lack of pleural effusion, pericardial effusion or lymphadenopathy on plain radiographs, should raise the clinical suspicion of H1N1 infection. Patients requiring hospital admission usually show slow clinical and radiological improvement, and require prolonged hospital stays.

  2. Cine-Club

    CERN Multimedia

    Cine-Club

    2011-01-01

    Thursday 10 November 2011 at 20:30 CERN Council Chamber The Counterfeiters / Die Fälscher By: Stefan Ruzowitzky (Germany/Austria, 2007) 98 min With: Karl Markovics, August Diel, Devid Striesow The Counterfeiters is the true story of the largest counterfeiting operation in history, set up by the Nazis in 1936. Master counterfeiter Salomon ‘Sally’ Sorowitsch, a Jew without morals, is arrested and sent to Mauthausen concentration camp, where he weasels through by offering his ‘artistic’ services. After transfer to Sachsenhausen he’s given an official alternative: taking ‘artistic’ charge of a cons teams assigned to produce perfect forgeries of allied banknotes for the Third Reich. Survivor Sally accepts, but conscience matters among the team prove no less dangerous then a sadistic jailer, which only the CO may keep in check. Original version German; English subtitles Entrance: 2 CHF Projection from DVD http://cine...

  3. CINE: Comet INfrared Excitation

    Science.gov (United States)

    de Val-Borro, Miguel; Cordiner, Martin A.; Milam, Stefanie N.; Charnley, Steven B.

    2017-08-01

    CINE calculates infrared pumping efficiencies that can be applied to the most common molecules found in cometary comae such as water, hydrogen cyanide or methanol. One of the main mechanisms for molecular excitation in comets is the fluorescence by the solar radiation followed by radiative decay to the ground vibrational state. This command-line tool calculates the effective pumping rates for rotational levels in the ground vibrational state scaled by the heliocentric distance of the comet. Fluorescence coefficients are useful for modeling rotational emission lines observed in cometary spectra at sub-millimeter wavelengths. Combined with computational methods to solve the radiative transfer equations based, e.g., on the Monte Carlo algorithm, this model can retrieve production rates and rotational temperatures from the observed emission spectrum.

  4. Cine Letras Goytisolo Cartelera

    Directory of Open Access Journals (Sweden)

    Flávio Pimenta de Souza

    2011-10-01

    Full Text Available Resumo: Estudo de investigação sobre a obra literária do escritor Juan Goytisolo em que se analisam comparativamente as técnicas cinematográficas do projeto Dogma 95 e as técnicas literárias do referido autor.Palavras-chave: Literatura espanhola; Juan Goytisolo; cinema.Resumen: Estúdio de investigación sobre la obra literaria del escritor Juan Goytisolo en el que se analizan comparativamente las técnicas cinematográficas del proyecto Dogma 95 y las técnicas literarias de dicho autor.Palabras-clave: Literatura española; Juan Goytisolo; cine.Keywords: Spanish literature; Juan Goytisolo; cinema.

  5. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology........ Methods The study is designed as an observational study with a narrative approach. The participant observations took place in a Danish radiological department and involved 20 examinations followed up by three semi-structured interviews. Conclusions Through emergent narratives radiographers construct...... and symptoms. The plot is organized in a relatively concrete and fairly limited space of possibilities, i.e. the number of different diagnoses that can be made. In opposition to the diagnostic plot stands the lifestory as a masterplot. In the lifestory the examination is plotted as a significant experience...

  6. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  7. Pediatric occipitocervical fixation: radiographic criteria, surgical technique, and clinical outcomes based on experience of a single surgeon.

    Science.gov (United States)

    Martinez-Del-Campo, Eduardo; Turner, Jay D; Rangel-Castilla, Leonardo; Soriano-Baron, Hector; Kalb, Samuel; Theodore, Nicholas

    2016-10-01

    OBJECTIVE If left untreated, occipitocervical (OC) instability may lead to serious neurological injury or death. Open internal fixation is often necessary to protect the neurovascular elements. This study reviews the etiologies for pediatric OC instability, analyzes the radiographic criteria for surgical intervention, discusses surgical fixation techniques, and evaluates long-term postoperative outcomes based on a single surgeon's experience. METHODS The charts of all patients atlantooccipital dislocation. The median number of fixated segments was 5 (occiput-C4). Structural bone grafts were used in all patients. Postsurgical neurological improvement was seen in 88.2% (15/17) of patients with chronic myelopathy and in 25% (1/4) of patients with acute myelopathy. Preoperatively, 42.5% (17/40) of patients were neurologically intact and remained unchanged at last follow-up, 42.5% (17/40) had neurological improvement, 12.5% (5/40) remained unchanged, and 2.5% (1/40) deteriorated. All patients had successful fusion at 1-year follow-up. The complication rate was 7.5% (3/40), including 1 case of vertebral artery injury. CONCLUSIONS Occipitocervical fixation is safe in children and provides immediate immobilization, with excellent survival and arthrodesis rates. Of the radiographic tools evaluated, the condyle-C1 interval was the most predictive of atlantooccipital dislocation.

  8. Movimientos migratorios y cine

    Directory of Open Access Journals (Sweden)

    Manuel Galiano León

    2009-12-01

    Full Text Available Nuestro artículo se ha centrado en el estudio de las películas de mayor distribución comercial para ver cómo éstas han representado el tema de la migración y qué reflexiones sugieren. En general, creemos que el reconocimiento por parte del cine de este fenómeno es positivo y que indudablemente constituye una fuente esencial para comprender las realidades migratorias distinguiendo discursos diversos y explicitando intenciones y hechos que intentan ocultarse u olvidarse.__________________ABSTRACT:Our article focuses on the study of the most commercial movies to check the way they present the subject of immigration and which kind of reflections they suggest. In general, we believe that the recognition of the migration phenomena in the cinema world is positive and it is actually an esential source to understand the reality of migration, being able to recognize different discourses and showing intentions and facts which are hidden or forgotten.  

  9. Cine-Club

    CERN Document Server

    Cine-Club

    2011-01-01

    Lundi 12 décembre 2011 à 18:30 Salle du Conseil Comme chaque année avant Noël, le CINE-CLUB du CERN est heureux d’inviter petits et grands à une projection gratuite du film : Ponyo sur la falaise (Japon, 2008, Hayao Miyazaki) Le petit Sosuke vit avec sa mère sur une haute falaise surplombant la mer. Un beau jour, il découvre sur la plage caillouteuse Ponyo, une petite fille poisson. Ponyo est si fascinée par Sosuke et le monde terrestre que son désir le plus cher est de devenir un être humain. Mais Fujimoto, son magicien de père, n’est pas du tout d’accord avec cette idée et il la force à regagner les profondeurs de l’océan. Bien décidée à revoir Sosuke, Ponyo s’échappe de sa prison sous-marine, mais ce faisant elle déclenche une immense catastroph...

  10. Cine Club - Special Event

    CERN Multimedia

    Cine Club

    2017-01-01

    Special event on Thursday 4 May 2017 at 18:30 CERN Council Chamber In collaboration with the CERN Running Club and the Women In Technology initiative, the CERN CineClub is happy to announce the screening of the film Free to Run Directed by Pierre Morath Switzerland, 2016, 99 minutes Today, all anybody needs to run is the determination and a pair of the right shoes. But just fifty years ago, running was viewed almost exclusively as the domain of elite male athletes who competed on tracks. With insight and propulsive energy, director Pierre Morath traces running's rise to the 1960s, examining how the liberation movements and newfound sense of personal freedom that defined the era took the sport out of the stadiums and onto the streets, and how legends like Steve Prefontaine, Fred Lebow, and Kathrine Switzer redefined running as a populist phenomenon. Original version French; English subtitles. http://freetorun.ch/ Come along to watch the film and learn more about the history of popular races and amat...

  11. Cine-Club

    CERN Multimedia

    CineClub

    2014-01-01

      On the occasion of CERN’s 60th anniversary the CERN CineClub will be showing films from all CERN member states Thursday 10 April 2014 at 20:00 CERN Council Chamber   The Bothersome Man     Directed by Jens Lien (Norway, 2006) 95 minutes   Forty-year-old Andreas arrives in a strange city with no memory of how he got there. He is presented with a job, an apartment-even a beautiful girlfriend. But before long, Andreas notices that something is wrong. The people around him seem cut off from any real emotion, and communicate only in superficialities. All this seems to be governed by a shadowy group of technicians, the ominous Caretakers’, who make sure the city runs smoothly. When they find Andreas is not adjusting to his new life, they keep an increasing watch over his activities...”The Bothersome Man” is a fantastic fable, a parable for modern society’s consumerism and obsession with ap...

  12. CERN CINE CLUB

    CERN Multimedia

    CERN CINE CLUB

    2010-01-01

    CERN CINE CLUB Thursday 24 June 2010 at 20:30 / Jeudi 24 Juin 2010 à 20:30 CERN Main Auditorium / Amphithéâtre Principal   The Raggedy Rawney By/de : Bob Hoskins (UK, 1988) - 104 min With/avec: Dexter Fletcher, Bob Hoskins, David Hill, Zoe Nathanson, Zoe Wanamaker Bob Hoskins makes his directorial debut with this lyrical, mystical fable about the strength of family and the transcendence of love. When a young military recruit named Tom goes AWOL after his first taste of battle, he must disguise himself with face paint and women’s clothing to avoid being captured by his vengeful commanding officer. He is instead discovered and taken in by Darky, the leader of an eccentric group of traveling gypsies, who thinks he is a «rawney», a half-mad, half-magical woman who brings good fortune. But when Tom begins a love affair with Darky’s daughter, he sets off a chain reaction of events that will soon put all of their lives in grave ...

  13. A critical evaluation of student radiographers' experience of the transition from the classroom to their first clinical placement

    International Nuclear Information System (INIS)

    Hyde, Emma

    2015-01-01

    Introduction: Students studying for qualifications which enable them to apply for registration as health care professionals are expected to undertake a large amount of clinical placement to support their learning. The BSc Hons Diagnostic Radiography at one post-1992 UK University is no exception. It was identified in a previous study by this researcher that a relatively large number of first year student radiographers were unsure, or nervous, about some aspects of the transition to their first clinical placement. It was felt that further investigation into the student experience of the transition to the first clinical placement was warranted. Methodology: A mixed-methods survey approach was used to elicit quantitative and qualitative data from current radiography students, academic staff and clinical staff about student experience of the transition to the first clinical placement. Results: In general, most students enjoyed their first clinical placement, and the opportunity to put theory into practice. However, three key themes emerged from the data that caused students difficulty in the first clinical placement; working with clinical staff, working with very ill patients, and moving around the department each week. Key Conclusions: This study has identified that some aspects of the transition into the first clinical placement need to be improved. Recommendations have been made for curriculum development in the academic block prior to the first clinical placement, and to improve student support during clinical placement. The implementation of these recommendations is crucial to reduce the dissonance between theory and practice, and improve student experience of the transition to the first clinical placement. - Highlights: • Issues for student radiographers during their first clinical placement are identified. • Recommendations made for curriculum development to improve preparation for clinical placement. • Recommendations made to improve student support in

  14. Limited magnetic resonance imaging in low back pain instead of plain radiographs: Experience with first 1000 cases

    Energy Technology Data Exchange (ETDEWEB)

    McNally, Eugene G.; Wilson, David J.; Ostlere, Simon J

    2001-11-01

    AIM: We report our experience with the first 1000 patients with non-traumatic low back pain (LBP) without radiculopathy undergoing limited sequence magnetic resonance imaging (MRI) instead of plain radiography. METHODS: Between January 1996 and December 1998, 1042 patients with low back pain unresponsive to conservative treatment were examined using a limited MR protocol comprising sagittal T1-weighted and STIR imaging. Plain radiographs were not performed. RESULTS: Malignancy, infection, vertebral fracture, spondylitis, pars defects and cord tumours were detected in 20%. Of the 82 osteoporotic vertebral fractures detected, 51 (62%) were recent and 31 had normal marrow signal indicating that they were old. Eighty pars defects were identified, 45(56%) had spondylolisthesis, 29(37%) were undisplaced and 6 (7%) had pars oedema only. Neoplastic disease was found in 17(8%) of which none was suspected before imaging. Benign neoplastic diseases such as vertebral AVM/haemangiomata were excluded. Twenty-one patients had a variety of disorders including ankylosing spondylitis (7), large vessel aneurysm (3), discitis (2), ovarian cyst (2), sequestered disc (2), sacral insufficiency fracture (2) and one patient each with burst fracture, retroperitoneal haematoma and a previously unsuspected horseshoe kidney. CONCLUSION: The majority of patients with LBP are best assessed clinically and imaging is usually not required. In patients with worrying symptoms, MRI with a limited protocol detects a greater number of abnormalities than previously reported studies using plain radiographs and has replaced plain radiography in our hospital. We report our experience with the first 1000 patients and highlight issues such as protocols, detection rates and communication issues. McNally E.G. et al. (2001)

  15. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  16. ¿Cine para qué? ¿Cine para quién?

    OpenAIRE

    Lluna, Catalina; Perazzo, Matías; Tegiachi, Luz

    2016-01-01

    El “cine arte”, “cine de autor” o sencillamente el cine independiente parece atenerse a reglas muy distintas que las películas comerciales. ¿Qué buscan los realizadores independientes? ¿En quién(es) piensan a la hora de desarrollar sus películas? Pensamos algunas de estas cuestiones a partir del análisis de una instancia del proyecto de tesis de Matías Perazzo, estudiante de cine.

  17. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  18. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  19. Assessment of voluntary deep inspiration breath-hold with CINE imaging for breast radiotherapy.

    Science.gov (United States)

    Estoesta, Reuben Patrick; Attwood, Lani; Naehrig, Diana; Claridge-Mackonis, Elizabeth; Odgers, David; Martin, Darren; Pham, Melissa; Toohey, Joanne; Carroll, Susan

    2017-10-01

    Deep Inspiration Breath-Hold (DIBH) techniques for breast cancer radiation therapy (RT) have reduced cardiac dose compared to Free Breathing (FB). Recently, a voluntary deep inspiration breath-hold (vDIBH) technique was established using in-room lasers and skin tattoos to monitor breath-hold. An in-house quality assessment of positional reproducibility during RT delivery with vDIBH in patients with left-sided breast cancer was evaluated. The electronic portal imaging device (EPID) was used in cinematographic (CINE) mode to capture a sequence of images during beam delivery. Weekly CINE images were retrospectively assessed for 20 left-sided breast cancer patients receiving RT in vDIBH, and compared with CINE images of 20 patients treated in FB. The intra-beam motion was assessed and the distance from the beam central axis (CA) to the internal chest wall (ICW) was measured on each CINE image. These were then compared to the planned distance on digitally reconstructed radiograph (DRR). The maximum intra-beam motion for any one patient measurement was 0.30 cm for vDIBH and 0.20 cm for FB. The mean difference between the distance from the CA to ICW on DRR and the equivalent distance on CINE imaging (as treated) was 0.28 cm (SD 0.17) for vDIBH patients and 0.25 cm (SD 0.14) for FB patients (P = 0.458). The measured values were comparable for patients undergoing RT in vDIBH, and for those in FB. This quality assessment showed that using in-room lasers and skin tattoos to independently monitor breath-hold in vDIBH as detected by 'on-treatment' CINE imaging is safe and effective. © 2017 The Royal Australian and New Zealand College of Radiologists.

  20. Miércoles al cine

    OpenAIRE

    Aguado Franco, Juan Carlos

    2014-01-01

    Se analiza un caso concreto de demanda ante una iniciativa empresarial: los miércoles al cine. Se analiza un caso concreto de demanda ante una iniciativa empresarial: los miércoles al cine. Fundamentos del Análisis Económico

  1. Cine y turismo: intersecciones polivalentes.

    OpenAIRE

    Rey-Reguillo, Antonia del

    2012-01-01

    Con el objeto de servir de introducción a los tres artículos que componen el dossier sobre Cine y Turismo contenido en la revista, este texto reflexiona someramente sobre el amplio abanico de intersecciones existente entre las industrias cinematográfica y turística ajustándose al caso concreto de la producción fílmica española considerada en tres etapas concretas: los documentales etnoturísticos surgidos en el período histórico correspondiente a la Segunda República, el documental 'España ins...

  2. Digital radiographic assessment of coronary flow reserve

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1985-01-01

    A method for measuring relative changes in regional blood flow using digital radiographic enhancement of selective coronary arteriography. Coronary flow reserve is measured in individual arterial distributions using the washin ratio of contrast appearance time under baseline and hyperemic conditions. Information is quantitatively presented in functional (parametric) image format. These images, termed contrast medium appearance pictures (CMAP), depict the transit of contrast through the arterial, myocardial and early venous stages. This process can be divided into three general phases: data acquisition, CMAP formation and CMAP analysis. The technique has evolved over its development period from a cine film-based technology which required substantial processing time to a real-time digital radiographic technique

  3. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital.......To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  4. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1983-01-01

    Radiographic elements are disclosed having first and second silver halide emulsion layers comprised of a dispersing medium and radiation-sensitive silver halide grains, and a support interposed between said silver halide emulsion layers capable of transmitting radiation to which said second silver halide emulsion layer is responsive. These elements are characterized in that at least said first silver halide emulsion layer contains tabular silver halide grains and spectral sensitizing dye adsorbed to the surface of the grains. Crossover can be improved in relation to the imaging characteristics. (author)

  5. Automatic segmentation of left ventricle in cardiac cine MRI images based on deep learning

    Science.gov (United States)

    Zhou, Tian; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong

    2017-02-01

    In developing treatment of cardiovascular diseases, short axis cine MRI has been used as a standard technique for understanding the global structural and functional characteristics of the heart, e.g. ventricle dimensions, stroke volume and ejection fraction. To conduct an accurate assessment, heart structures need to be segmented from the cine MRI images with high precision, which could be a laborious task when performed manually. Herein a fully automatic framework is proposed for the segmentation of the left ventricle from the slices of short axis cine MRI scans of porcine subjects using a deep learning approach. For training the deep learning models, which generally requires a large set of data, a public database of human cine MRI scans is used. Experiments on the 3150 cine slices of 7 porcine subjects have shown that when comparing the automatic and manual segmentations the mean slice-wise Dice coefficient is about 0.930, the point-to-curve error is 1.07 mm, and the mean slice-wise Hausdorff distance is around 3.70 mm, which demonstrates the accuracy and robustness of the proposed inter-species translational approach.

  6. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  7. O Cine Debate promovendo encontros do cinema com a escola

    Directory of Open Access Journals (Sweden)

    Andreza Berti

    2013-12-01

    Full Text Available Partindo da hipótese-cinema, de Alain Bergala (2008, reconhecemos o cinema como alteridade, pois a experiência com o cinema permite ser o outro, viver em outro território, flanar por diferentes espaços e tempos. Nesse processo, o cinema pode entrar na escola como potência criadora: promover o encontro dos(as alunos(as com diferentes experiências estéticas; provocar a dúvida, o questionamento, colocando em xeque o lugar-comum, os padrões socioculturais, as identidades fixas. A experiência com Cine Debate em escolas públicas de Ensino Médio, nos municípios do Rio de Janeiro e Niterói, permitiu problematizar a produção cinematográfica, favorecer a aproximação do cinema com a escola, contribuir para a ampliação do número de filmes brasileiros assistidos, questionar o que consideramos "olhar". Por meio de uma pesquisa qualitativa, percebemos o desejo dos estudantes em aprofundar os temas discutidos, conhecemos seus gêneros cinematográficos preferidos e a frequência com que assistem a filmes. Esse resultado indica a continuidade da experiência com o Cine Debate.

  8. Radiographers' and radiology practitioners' opinion, experience and practice of benefit-risk communication and consent in paediatric imaging

    International Nuclear Information System (INIS)

    Portelli, J.L.; McNulty, J.P.; Bezzina, P.; Rainford, L.

    2016-01-01

    Objectives: To investigate radiographers' and radiology practitioners' opinion, experience and practice of radiation benefit-risk communication and consent for paediatric imaging examinations. Methods: A cross-sectional survey was conducted amongst radiographers and radiology practitioners working at a primary paediatric referral centre in Malta, so as to acquire information about their interactions with paediatric patients and/or their parents, particularly their opinion and practice of communicating benefit-risk information and seeking consent for imaging examinations. Results: The return of 112 questionnaires provided a response rate of 66.7%. Findings revealed varied practice relating to the provision of benefit-risk information, whereby details concerning examination benefits and potential risks are not always conveyed. For 89% of participants, parental consent was sought for paediatric imaging examinations in their current practice. Only 36.7% of participants indicated that they were highly confident in their ability to communicate benefit-risk information. The study findings also revealed that parents can truly be worried about the associated radiation exposure, with some even refusing an imaging examination as a result of such concerns. Conclusions: The practice of communicating benefit-risk information to paediatric patients and/or their parents is varied. A possible gap in benefit-risk communication education and/or training was identified, which may impact radiographers' and radiology practitioners' confidence in conveying such information. Education/training activities for radiographers and radiology practitioners are therefore necessary to foster improved benefit-risk dialogues and help provide reassurance to parents/guardians about the benefits of appropriately indicated paediatric imaging examinations. - Highlights: • The practice of communicating radiation benefit-risk information to parents of paediatric patients is varied.

  9. Cine MR imaging of valvular heart disease

    International Nuclear Information System (INIS)

    Underwood, S.R.; Firmin, D.N.; Mohiaddin, R.H.; Klipstein, R.H.; Bogren, H.G.; Rees, R.S.O.; Longmore, D.B.

    1987-01-01

    Cine MR imaging shows details of cardiac valve motion and the turbulence caused by regurgitation and stenosis. In 30 patients, the area of turbulence proximal to regurgitant valves correlated well with the regurgitant fraction measured from right and left ventricular stroke volumes. Turbulence distal to stenotic valves did not correlate with the pressure gradient because abnormal valves that were not stenosed produced turbulence. Valve motion and the presence of thrombus were easier to assess than in conventional images. Cine MR imaging provides an important addition to conventional imaging in valvular regurgitation, but pressure gradients cannot be assessed in valvular stenosis

  10. Cine vasco y euskera: debates de identidad

    OpenAIRE

    Fernández, Joxean

    2013-01-01

    INTRODUCCIÓN: LA ÓSMOSIS HISTORIA-CINE Los físicos suelen hablar de ósmosis para referirse al paso recíproco de dos líquidos de distinta densidad a través de una membrana semipermeable que los separa. Asimismo, en lenguaje literario, hablamos de ósmosis para definir simplemente influencias recíprocas. Nos permitimos utilizar aquí este término prestado de otras disciplinas científicas para tratar de obtener una imagen de las relaciones que el cine y la historia vienen manteniendo desde que aqu...

  11. Cine y estadística

    OpenAIRE

    Sorando, José M.

    2012-01-01

    Hay estadísticas de cualquier tema, también de cine. Algunas son tan chocantes como la que recoge la tabla 1, para fans de las películas de rambo. Es una simple estadística descriptiva que no va más allá de las frecuencias de tiroteos y decesos, de ella se desprende alguna conclusión, como la virulencia creciente de la serie; y alguna sospecha, como su posible relación con la abstinencia sexual… Claro que hay otras estadísticas de cine más respetables.

  12. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  13. Moto-cine en Madrid – Barajas

    Directory of Open Access Journals (Sweden)

    Chueca Goitia, Fernando

    1959-05-01

    Full Text Available Madrid, después de Roma, ha sido la segunda capital de Europa que ha construido y puesto en funcionamiento un motocine, es decir, un cine para automóviles, con arreglo a los últimos adelantos que este tipo de espectáculos ha llegado a alcanzar.

  14. Experimental study on quantitative evaluation of slow pulsatile flow of CSF with cine MRI

    International Nuclear Information System (INIS)

    Matsuda, Masao

    1991-01-01

    The present study was designed to evaluate the slow pulsatile flow of cerebrospinal fluid (CSF) quantitatively with cine MRI in phantom experiment for the clinical application. The flow phantom was constructed from a plastic tube with a narrow channel to represent the central aqueduct. The phantom was filled with water to represent the CSF. The second tube filled with stationary water was positioned beside the flow phantom and acted as a control for no-flow signal strength. The ratio of signal intensity in regions of interest for the flow phantom and the control was measured. Not only the actual velocity curve of the flowing water through the phantom but also the temporal profile of signal intensity showed two main peaks with other small peaks in one cycle. This suggested a close relationship between signal intensity of cine MRI and flow velocity. A significant correlation between the signal intensity ratio and the velocity was obtained on cine MRI pulse sequences. Cine MRI was thus found to have the ability to give quantitative information about slow pulsatile flow. The most suitable pulse sequence was fast imaging with steady state free precession pulse sequence at the flip angle between 50 and 90 degrees. This preliminary study suggests that the slow pulsatile flow of CSF passing along the aqueduct can be visualized and measured. Thus, the sequence proposed has a potential for the investigation of normal and disturbed CSF circulation and the mapping of the flow pattern in different pathological conditions. (N.K.)

  15. From the clinical to the managerial domain: the lived experience of role transition from radiographer to radiology manager in South-East Queensland.

    Science.gov (United States)

    Thompson, Alarna M N; Henwood, Suzanne M

    2016-06-01

    This study seeks to add to current literature a descriptive account of the lived experience of radiographers' transition to, and experiences of, management roles and identifies additional resources and support that are perceived as being beneficial for this transition. This study employed a descriptive phenomenological stance. Using purposive sampling, six South-East Queensland based private practice radiology managers, who had held their position for longer than 3 months, participated in audiotape recorded in-depth interviews exploring their transition to, and experiences of management in radiology. Thematic analysis was used to describe and make meaning of the data. Overall, five central themes emerged through thematic analysis of the data. The results indicate that all participants' had an underlying drive to succeed during their role transition and highlight the importance of a comprehensive orientation by a mentor; the training and support to enable preparation for the role, especially in the area of people management skills and communication; the importance of access to networking opportunities and the importance of concise expectations from higher management. Role transition can be marred with uncertainty, however; key suggestions indicate the importance of having support mechanisms in place before, during and after transitioning to a managerial role.

  16. Cine MR imaging of internal derangements of the knee

    International Nuclear Information System (INIS)

    Niitsu, M.; Anno, I.; Ishikawa, N.; Akisada, M.; Fukubayashi, T.

    1990-01-01

    This paper assesses internal derangements of the knee joint by a new method of cine MR imaging. Cine MR imaging, involving cine acquisition of kinematic sagittal images during knee movement, was used to evaluate 51 symptomatic patients and 19 healthy subjects. Cine MR images of cruciate ligament fears showed disappearance of low-intensity bundles during knee movement, periodic appearance of joint fluid in the area of the ligament, and irregular tibial movement. Cine MR images of meniscal tears showed independent movement of meniscal fragments and periodic tear opening and closing. Twenty-seven of the 28 anterior cruciate ligament (ACL) tears confirmed arthroscopically were correctly identified with cine MR imaging, with a sensitivity of 96% and a specificity of 92%

  17. How to perform and interpret cine MR enterography.

    Science.gov (United States)

    Wnorowski, Amelia M; Guglielmo, Flavius F; Mitchell, Donald G

    2015-11-01

    Magnetic resonance (MR) enterography has become a fundamental tool for small bowel evaluation. Multiphasic cine imaging is a useful component of MR enterography evaluation because it provides functional information about bowel motility. Cine MR enterography can be used to evaluate for strictures and adhesions. Bowel motility evaluation has been shown to increase pathologic lesion detection in Crohn's disease and has been incorporated into disease activity scoring systems. Currently, cine MR enterography remains underutilized. The purpose of this article is to outline how to perform and interpret cine MR enterography. The authors describe how to perform a multiphasic balanced steady state free precession sequence using different MR systems and give practical advice on how to display and interpret the cine sequence. Sample cases illustrate how the cine sequence complements standard MR enterography evaluation with T2 -weighted, contrast-enhanced T1 -weighted, and diffusion-weighted imaging. © 2015 Wiley Periodicals, Inc.

  18. Requirements and Solutions for Archiving Scientific Data at CINES

    Science.gov (United States)

    Coutin, Stephane

    Historically an high-performance computing datacenter, the “Centre Informatique National de l’Enseignement Supérieur” (CINES) has also a mission of long term digital preservation. By coupling those two areas, it became obvious that CINES had to understand and take into account the requirements of scientific communities regarding their data life cycle, and more specifically their archiving requirements. We will present those requirements and describe the platforms CINES proposes for each service class.

  19. Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs.

    Science.gov (United States)

    Kim, Tae-Young; Choi, Jin-Woo; Lee, Sam-Sun; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul

    2011-03-01

    The aim of this study was to evaluate the effect of liquid crystal display (LCD) monitor type and observer experience on the diagnostic performance in soft-copy interpretations of maxillary sinus inflammatory lesions on panoramic radiographs. Ninety maxillary sinuses on panoramic images were grouped into negative and positive groups according to the presence of inflammatory lesions, using CT for confirmation. Monochrome and color LCDs were used. Six observers participated and ROC analysis was performed to evaluate the diagnostic performance. The reading time, fatigue score, and inter-/intra-observer agreements were assessed. The interpretation of maxillary sinus inflammatory lesions was affected by the LCD monitor type used and by the experience of the observer. The reading time was not significantly different, however the fatigue score was significantly different between two LCD monitors. Inter-observer agreement was relatively good in experienced observers, while the intra-observer agreement for all observers was good with monochrome LCD but not with color LCD. The less experienced observers showed lowered diagnostic ability with a general color LCD.

  20. X-Ray Radiographic Observation of Directional Solidification Under Microgravity: XRMON-GF Experiments on MASER12 Sounding Rocket Mission

    Science.gov (United States)

    Reinhart, G.; NguyenThi, H.; Bogno, A.; Billia, B.; Houltz, Y.; Loth, K.; Voss, D.; Verga, A.; dePascale, F.; Mathiesen, R. H.; hide

    2012-01-01

    The European Space Agency (ESA) - Microgravity Application Promotion (MAP) programme entitled XRMON (In situ X-Ray MONitoring of advanced metallurgical processes under microgravity and terrestrial conditions) aims to develop and perform in situ X-ray radiography observations of metallurgical processes in microgravity and terrestrial environments. The use of X-ray imaging methods makes it possible to study alloy solidification processes with spatio-temporal resolutions at the scales of relevance for microstructure formation. XRMON has been selected for MASER 12 sounding rocket experiment, scheduled in autumn 2011. Although the microgravity duration is typically six minutes, this short time is sufficient to investigate a solidification experiment with X-ray radiography. This communication will report on the preliminary results obtained with the experimental set-up developed by SSC (Swedish Space Corporation). Presented results dealing with directional solidification of Al-Cu confirm the great interest of performing in situ characterization to analyse dynamical phenomena during solidification processes.

  1. Friday Programme for CineGlobe 2015

    CERN Multimedia

    Marcelloni De Oliveira, Claudia

    2015-01-01

    Workshops, apero with filmmakers and short-films inspired by science were the menu of the festival through the day. At night the CineGlobe DOME shown with the 360 degree projections shot-films; among them the avant-premiere of "Phantom of the Universe" - a movie that explains Dark Matter, directed by Joao Pequenao. Meanwhile at the Globe, the audience could enjoy the projections of the sequence of " The Invisible Photograph" .

  2. Entre la Historia y el Cine

    Directory of Open Access Journals (Sweden)

    Luisa Fernanda Acosta

    1995-01-01

    Full Text Available Este trabajo se propone aplicar al cine el concepto de «fuente histórica». El uso de medios de comunicación como el cine está íntimamente relacionado con las necesidades y posibilidades de una sociedad, lo que implica una relación muy cercana entre el desarrollo social y económico de una comunidad, y los mecanismos que ella genera como canales de expresión y comunicación. El cine, conjugación de imagen, sonido y movimiento se convierte para la sociedades contemporáneas en una gran alternativa como fuente histórica, que provee al investigador ópticas diferentes de una realidad ya explorada. Un gesto, una mirada, un plano, una secuencia, se traducen en frases y párrafos, que generan una versión diferente de la historia, una redacción que se lee en imágenes y que narra otro punto de vista, un relato oculto que tiene todo por contar.

  3. Cine-MR imaging of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Allmann, K.H.; Uhl, M.; Gufler, H.; Kotter, E.; Langer, M. [Univ. Hospital, Freiburg (Germany). Dept. of Diagnostic Radiology; Biebow, N.; Hauer, M.P.; Reichelt, A. [Univ. Hospital, Freiburg (Germany). Dept. of Orthopedic Surgery

    1997-11-01

    Purpose: Shoulder lesions are usually examined with the joint in only one or two positions. We examined the shoulder with the joint in a variety of positions. We also assessed the application of cine-MR to the detection of instability and impingement. Material and Methods: The cine-MR examinations were performed in 30 patients and 15 healthy volunteers. We used an open 0.2 T system and a closed 1.0 T system. Spoiled gradient echo 2D T1-weighted images and turbo spin-echo T1- and T2-weighted images were obtained with a field of view of 180 mm. The examinations were videotaped and evaluated later. Results: Normal variations of the glenohumeral joint were easy to recognize. Subluxations and luxations of the humeral head as well as rupture of the labrum were identified. It was also possible to identify the labrum with a signal change after arthroscopic refixation. And we were able to objectively assess distances between the osseous structures during dynamic movement. Conclusion: Unlike static MR, cine-MR would appear to be useful in visualizing the capsular ligament complex of the gleno-humeral joint in impingement and instability. It also provides information on dynamic changes and may thus prove to be an important tool for shoulder diagnostics. The method may provide an early diagnosis in the subacromial impingement syndrome. (orig.).

  4. Cine MR imaging of the cardiovascular system

    International Nuclear Information System (INIS)

    Nishimura, Fumiaki; Yoshino, Yasushi; Mihara, Junji; Ichikawa, Seiichi; Kimura, Masahiko; Yano, Masao; Umeda, Masahiro; Oouchi, Toshihiro

    1990-01-01

    In recent years cine magnetic resonance imaging (MRI) has developed as a high-speed imaging technique that provides a high intensity signal even at a short repetition time (20-30 msec) by using an excited pulse with a small flip angle according to the gradient echo method, enabling about 20 to 30 continuous images of the same section per one cardiac cycle to be taken. On cine display of these continuous images, information concerning blood flow shown by a high intensity signal in comparison with that of the myocardium and vascular wall is obtained with high temporal resolution along with anatomical information. The present study reports the clinical usefulness of cine MRI in today's situation, inculding the following: calculation of the left ventricular ejection fraction and pulmonary-to-systemic flow ratio in congenital shunt disease by integration of the area of multisections through application of Simpson's method; diagnosis of the severity of valvular regurgitation, evaluation of stenosal diseases, and diagnosis of inflow from the fissured entry of dissecting aortic aneurysm by evaluating of an area of low intensity signal, probably based on the high velocity or turbulent blood flow: and evaluation of patency of the internal mammary artery bypass graft of the basis of the possible visualization of even thin blood vessels because of the high intensity signal of blood flow. In particular, the characteristics of this procedures are described by comparing it with other technologies in the field of diseases of valvular regurgitation. (author)

  5. Cine MRI of patients with cervical myelopathy

    International Nuclear Information System (INIS)

    Ukita, Yasutaka

    1993-01-01

    Forty-six patients with cervical myelopathy were examined before and after surgery by cine magnetic resonance imaging (MRI). According to the occurrence site and degree of flow void, cerebrospinal fluid (CSF) flow void was classified into five: anterior type (flow void mainly in the anterior part of subarachnoid space), posterior type (mainly in the posteiror part), anteroposterior type (in the anterior and posterior parts), incomplete block type (flow void limited to the upper and lower parts of the block), and complete block type (no flow void). None of the 46 patients had normal CSF flow void on cine MRI before surgery. CSF flow void was seen in systolic phase on ECG (from 150 to 300 msec from R's wave) in all patients after spinal cord decompression. Postoperative CBF flow void types correlated well with surgical method, disease, and postoperative vertebral alignment. Postoperative outcome was the most excellent in the group of posterior type and the poorest in the group of anteroposterior type, showing a significant difference between the groups. Cine MRI is a useful noninvasive, dynamic method for assessing postoperative decompression effect. (N.K.)

  6. Cine-MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Allmann, K.H.; Uhl, M.; Gufler, H.; Kotter, E.; Langer, M.; Biebow, N.; Hauer, M.P.; Reichelt, A.

    1997-01-01

    Purpose: Shoulder lesions are usually examined with the joint in only one or two positions. We examined the shoulder with the joint in a variety of positions. We also assessed the application of cine-MR to the detection of instability and impingement. Material and Methods: The cine-MR examinations were performed in 30 patients and 15 healthy volunteers. We used an open 0.2 T system and a closed 1.0 T system. Spoiled gradient echo 2D T1-weighted images and turbo spin-echo T1- and T2-weighted images were obtained with a field of view of 180 mm. The examinations were videotaped and evaluated later. Results: Normal variations of the glenohumeral joint were easy to recognize. Subluxations and luxations of the humeral head as well as rupture of the labrum were identified. It was also possible to identify the labrum with a signal change after arthroscopic refixation. And we were able to objectively assess distances between the osseous structures during dynamic movement. Conclusion: Unlike static MR, cine-MR would appear to be useful in visualizing the capsular ligament complex of the gleno-humeral joint in impingement and instability. It also provides information on dynamic changes and may thus prove to be an important tool for shoulder diagnostics. The method may provide an early diagnosis in the subacromial impingement syndrome. (orig.)

  7. CineGlobe Film Festival, Wednesday programme with Science Story Telling Hackathon and Oculus Rift

    CERN Multimedia

    Marcelloni De Oliveira, Claudia

    2015-01-01

    Besides the short-film competitions, the second day of 2015 CineGlobe included a Soirée Oculus Rift with the public launch of the “Storytelling Science” Hackathon. CineGlobe and Festival Tous Ecrans joined forces to launch the “Storytelling Science” hackathon, in collaboration with Tribeca Film Institute and LIFT Conference. The keynote speech was given by renowned filmmaker and transmedia creator Michel Reihlac, who spoke about the role of interactive and immersive storytelling techniques in cinematic narrative. By placing the viewer in the center of the story, these new technologies are profoundly changing the way we tell stories. Michel Reilhac designs innovative story based experiences, using digital platforms (cinema, tv, mobile, tablets, …) and real life events. His creative approach to storytelling ambitions to offer viewers/ participants a unique opportunity for an immersive, participatory and interactive experience. During the evening, Oculus Rift virtual reality headsets were available to...

  8. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  9. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  10. Intramyocardial strain estimation from cardiac cine MRI.

    Science.gov (United States)

    Elnakib, Ahmed; Beache, Garth M; Gimel'farb, Georgy; El-Baz, Ayman

    2015-08-01

    Functional strain is one of the important clinical indicators for the quantification of heart performance and the early detection of cardiovascular diseases, and functional strain parameters are used to aid therapeutic decisions and follow-up evaluations after cardiac surgery. A comprehensive framework for deriving functional strain parameters at the endocardium, epicardium, and mid-wall of the left ventricle (LV) from conventional cine MRI data was developed and tested. Cine data were collected using short TR-/TE-balanced steady-state free precession acquisitions on a 1.5T Siemens Espree scanner. The LV wall borders are segmented using a level set-based deformable model guided by a stochastic force derived from a second-order Markov-Gibbs random field model that accounts for the object shape and appearance features. Then, the mid-wall of the segmented LV is determined based on estimating the centerline between the endocardium and epicardium of the LV. Finally, a geometrical Laplace-based method is proposed to track corresponding points on successive myocardial contours throughout the cardiac cycle in order to characterize the strain evolutions. The method was tested using simulated phantom images with predefined point locations of the LV wall throughout the cardiac cycle. The method was tested on 30 in vivo datasets to evaluate the feasibility of the proposed framework to index functional strain parameters. The cine MRI-based model agreed with the ground truth for functional metrics to within 0.30 % for indexing the peak systolic strain change and 0.29 % (per unit time) for indexing systolic and diastolic strain rates. The method was feasible for in vivo extraction of functional strain parameters. Strain indexes of the endocardium, mid-wall, and epicardium can be derived from routine cine images using automated techniques, thereby improving the utility of cine MRI data for characterization of myocardial function. Unlike traditional texture-based tracking, the

  11. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  12. El cine de terror español

    OpenAIRE

    Gómez Llorente, Tatiana

    2015-01-01

    La autora comienza haciendo un estudio del cine de terror desde sus inicios, sus subgéneros, mecanimos utilizados para provocar el miedo en el espectador para finalmente centrarse en el cine de terror español a través de cinco películas representativas del género.

  13. Automatic segmentation and disease classification using cardiac cine MR images

    NARCIS (Netherlands)

    Wolterink, Jelmer M.; Leiner, Tim; Viergever, Max A.; Išgum, Ivana

    2018-01-01

    Segmentation of the heart in cardiac cine MR is clinically used to quantify cardiac function. We propose a fully automatic method for segmentation and disease classification using cardiac cine MR images. A convolutional neural network (CNN) was designed to simultaneously segment the left ventricle

  14. Reflections on the role of consultant radiographers in the UK: what is a consultant radiographer?

    OpenAIRE

    Booth, Lisa; Henwood, Suzanne; Miller, Paul K.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK.\\ud \\ud Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore tw...

  15. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  16. Radiographic assessment of endodontic working length

    Directory of Open Access Journals (Sweden)

    Osama S Alothmani

    2013-01-01

    Full Text Available The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected by the location of the apical foramen, tooth type, canal curvature and superimposition of surrounding structures. Variations among observers by virtue of training and experience may also influence the accuracy of the procedure. The interpretation of radiographs could be affected by film speed and viewing conditions, with the superiority of digital imaging over conventional radiography for working length determination remaining debatable. The combination of several methods is recommended for acquiring the most accurate working length.

  17. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    a new PACS technology and digital workflow. Using PACS technology, together with an adjustment to the new system workflow, the experience among radiographers was that the production of images increased and as a result the stress in work increased as well. Using PACS technology, medical staff had little control over the organization of image production and its workflow, so that radiographers experienced PACS as a more technical deterministic system allowing small human control in the organization of work.

  18. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality was tes...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  19. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  20. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  1. Discursos subversivos en el cine no hablado

    Directory of Open Access Journals (Sweden)

    Rodríguez Fernández, M.ª del Carmen

    2012-12-01

    Full Text Available “Subversive discourses in silent films” aims to analyse the gender transgression that emerges in certain movies of the silent period. These being silent films, their meaning can only be understood from the content of the images. Directors of the silent period were aware of the importance of images and of their power to put across their views to spectators. The field of filmmaking was new but it was not ungendered, and women filmmakers knew that their films were the vehicle to make spectators aware of their feminist positions. Le matelas alcoolique, La souriante Mme. Beudet and Dora Films of America Shorts are examples of this privilege since, although they belong to two periods of silent film history and have different aims, the directors and the films selected are good examples to be revisited with a gender perspective.

    “Discursos subversivos en el cine no hablado” se propone analizar las transgresiones de género que aparecen en algunas películas del cine mudo. Por sus características al tratarse de un cine no hablado, lo que sugieren algunas imágenes es fundamental para entender los significados de las películas. Las directoras de aquella época eran conocedoras de la importancia de las imágenes y del poder que les confería la cámara para expresar sus reivindicaciones al público espectador. El campo de la cinematografía era nuevo, pero tenía género y las directoras sabían que sus películas eran el vehículo para dar a conocer su articulación como feministas. Le matelas alcoolique, La souriante Mme. Beudet y Dora Films of America Shorts son ejemplos de este privilegio puesto que, aunque las películas de esta muestra pertenezcan a dos etapas del cine mudo y de que sus propósitos fueran diferentes, las directoras y las películas seleccionadas son ejemplos merecedores de una revisión con perspectiva de género.

  2. Erotismo, pornografía y cine

    Directory of Open Access Journals (Sweden)

    José Rojas Bez

    2015-01-01

    Full Text Available ¿Qué es el erotismo? ¿Qué es la pornografía? ¿En qué medida influyen sobre el espectador? Cómo responder educativamente ante las diversas manifestaciones suyas en el cine y los demás medios artísticos? El autor reflexiona sobre estas cuestiones esenciales, distingue ambos conceptos y propone respuestas desprejuiciadas, no preconcebidas, sino fundamentales, desde puntos de vista educativos, estéticos y críticos.

  3. Psicología y cine: TID

    OpenAIRE

    Nuñez García, Cristina

    2013-01-01

    Partiendo de la base de que en el día a día no podemos encontrar la mayoría de los trastornos que se encuentran en el DSM-IV y en el CIE-10, el cine nos hace un acercamiento a estos haciéndolos más divulgativos y ejemplificando dichos trastornos aunque no siempre con la realidad deseada. Por eso mismo vamos a tratar el trastorno de identidad disociativo para profundizar en él, trabajando desde la historia del mismo, sus características, diagnóstico,... Trataremos de ejemplificar casos de TID ...

  4. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  5. Applied pathology for radiographers

    International Nuclear Information System (INIS)

    Laudicina, P.

    1987-01-01

    This book presents a basic text for the student of radiologic sciences. It includes most of the pathology recommended by the ASRT Curriculum Guide. Radiographic technique and positioning are examined when relevant to obtaining quality radiographs of specific disease conditions. Brief overviews of these conditions include background etiology, diagnosis, treatment and prognosis. Many illustrations are included to enhance understanding

  6. Application of cine MRI-tagging method to aortic dessection

    International Nuclear Information System (INIS)

    Yoshioka, Kunihiro; Takahashi, Tsuneo; Kamata, Hiroyuki; Kikuchi, Kenichi; Yamaguchi, Kojiro.

    1992-01-01

    For the evaluation of aortic dissection, ECG-gated SE or cine MR imaging has been usually performed. However, detection of slow flow in the false lumen and differentiation between mural thrombus and slow flow are sometimes difficult. Because paradoxical enhancement due to slow blood flow simulates thrombus. We performed cine MR imaging with persaturation tagging, which clearly showed differentiation between thrombus and paradoxical enhancement. We concluded that cine MR imaging with tagging method was useful to evaluate the slow flow and thrombus in the false lumen. (author)

  7. Validation of regional myocardial perfusion with cine CT

    International Nuclear Information System (INIS)

    Gould, R.G.; McNamara, T.; Koshold, S.; Lipton, M.; Sievers, R.; Higgins, C.B.; Boyd, D.

    1986-01-01

    Blood flow within each of eight quadrants of the myocardium was measured in dogs using a cine-CT scanner and also with microspheres. Cine-CT flow measurements were made using a nonionic contrast agent and flow was calculated by a formula that used both the maximum iodine concentration and the peak delay time. Measurements were obtained at rest and during hyperperfusion induced by chromonar. Simultaneous cine-CT and microsphere measurements correlated (slope = 0.71 r = .8) over a range of 0.4-7.0 ml/min/g

  8. Cine CT in the evaluation of coronary bypass graft patency

    International Nuclear Information System (INIS)

    Stanford, W.; Rooholamini, M.; Rumberger, J.; Marcus, M.; Hiratzka, L.

    1986-01-01

    Cine CT produces axial images over an 8-cm section of the aorta in 50 msec. This characteristic makes the technique useful for evaluating coronary bypass graft (CBG) patency. With the use of 40 ml of 67% iothalamate sodium injected via an antecubital vein, 28 patients with 68 CBGs underwent cine CT. Ten patients with 21 CBGs also underwent cardiac catheterization. In the latter group the overall accuracy of cine CT compared to cardiac catheterization was 95.2% (20/21). The sensitivity was 94.1% (16/17), and the specificity was 100% (4/4). This figure compares favorably with the 92% sensitivity achieved with conventional CT

  9. MUJERES DIRECTORAS DE CINE: UN RETO, UNA ESPERANZA

    OpenAIRE

    Trinidad Núñez Domínguez

    2010-01-01

    Este trabajo parte de considerar que analizar el cine con perspectiva de género tiene potencia educadora. El objetivo general del mismo es hacer un recorrido por los últimos veinte años de cine dirigido por mujeres (1989-2009). Dicho objetivo se concreta en dos: conocer quiénes son las mujeres que lideran el cine español tomando decisiones y rompiendo barreras (económicas, de gestión o de credibilidad) y conocer las características de sus trabajos. Proponemos un estudio centrado en la direcci...

  10. Mujeres directoras de cine: un reto, una esperanza

    OpenAIRE

    Núñez Domínguez, Trinidad

    2010-01-01

    Este trabajo parte de considerar que analizar el cine con perspectiva de género tiene potencia educadora. El objetivo general del mismo es hacer un recorrido por los últimos veinte años de cine dirigido por mujeres (1989-2009). Dicho objetivo se concreta en dos: conocer quiénes son las mujeres que lideran el cine español tomando decisiones y rompiendo barreras (económicas, de gestión o de credibilidad) y conocer las características de sus trabajos. Proponemos un estudio centrado e...

  11. Raras y olvidadas: directoras de cine mudo

    Directory of Open Access Journals (Sweden)

    Rosa Mª Ballesteros García

    2015-10-01

    Full Text Available Este artículo sobre la dirección de mujeres durante la época del cine mudo (o silente, se resume como una época en que estas amazonas, sugerente apelativo ya utilizado por la filósofa Victoria Sendón, practicaron lo que alguien ha denominado “Heroísmo cotidiano”; un heroísmo que, por otra parte, se sigue practicando. Utilizando diversas fuentes hemos sacado a la luz más de un centenar de mujeres, profesionales del cine de la primera época que, saltándose las normas establecidas, no sólo prestaron su imagen como imán atractivo sino que, en línea con sus compañeros de profesión, se situaron tras las cámaras produciendo y dirigiendo sus propias películas durante aquellos oscuros y desconocidos años para el gran público. Con ello deseamos revivir algunos de los nombres de estas valientes mujeres, ninguneadas o ignoradas por la Historia.

  12. Cine transnacional, el sistema de festivales y la transformación digital

    Directory of Open Access Journals (Sweden)

    Thomas ELSAESSER

    2015-12-01

    Full Text Available Este artículo considera la idea del cine transnacional desde varias perspectivas distintas: primero, como un término que compite con otros -tales como “cine del mundo”, “cine independiente”, “cine con acento” o “cine periférico”-, que buscan también definir el cine no hollywoodiense. A pesar de ser en sí mismo un concepto problemático, el término “cine transnacional” es el que mejor representa la situación de la cinematografía actual bajo las condiciones que marca la globalización. En segundo lugar, el cine transnacional resalta los desafíos, contradicciones y posibilidades de su principal punto de encuentro e intercambio: el circuito de festivales internacionales de cine. En tercer lugar, el cine transnacional nos ayuda a entender los cambios producidos por el “giro digital” en el cine no hollywoodiense y, de este modo, redefine lo que queremos decir en la actualidad con “cine nacional”, “cine de autor” y “cine de pequeñas naciones”.

  13. El cine en el cine: Los abrazos rotos (Pedro Almodóvar, 2009

    Directory of Open Access Journals (Sweden)

    Pedro Poyato

    2012-10-01

    Full Text Available El cine en el cine, tema recurrente en la filmografía de Pedro Almodóvar, protagoniza también Los abrazos rotos, película que contiene en su interior otra titulada Chicas y maletas. Pero las imágenes de esta segunda película, trasunto de otra anterior del propio Almodóvar, Mujeres al borde un ataque de nervios, coexisten con las de un documental sobre su rodaje. El resultado es una proliferación de imágenes segundas que, incorporadas según una estructura en abismo, el filme va a conjugar de múltiples y variadas maneras. El presente trabajo trata de dar cuenta de la génesis, funcionamiento y declinación de estas imágenes segundas y de los sentidos que de ello emanan.

  14. Evaluation of aortic regurgitation using cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tamai, Takuya; Konishi, Tokuji; Okamoto, Shinya; Sakuma, Hajime; Takeda, Kan; Nakano, Takeshi

    1993-01-01

    Cine magnetic resonance imaging (MRI) was used to assess aortic regurgitation (AR) in 13 patients with valvular disease and 3 normal subjects, and the results were compared to color Doppler flow mapping findings. AR produced a signal void in the left ventricle during the diastolic phase in all patients by MRI. There were no false positive or negative results compared with echocardiographic findings. Visual grading of cine MRI gave results similar to color flow Doppler echocardiography (88%). The distance and the area of aortic regurgitation using MRI correlated well with color Doppler flow mapping (r=0.82 and 0.88). However, measurements of distance and area by color flow Doppler tended to be larger than those by cine MRI. With current techniques echocardiography may overestimate the severity of AR as compared with cine MRI. In addition, MRI gives clinically useful information in patients in whom transthoracic Doppler echocardiography is not adequate. (author)

  15. Automated Motion Estimation for 2D Cine DENSE MRI

    Science.gov (United States)

    Gilliam, Andrew D.; Epstein, Frederick H.

    2013-01-01

    Cine displacement encoding with stimulated echoes (DENSE) is a magnetic resonance (MR) method that directly encodes tissue displacement into MR phase images. This technique has successfully interrogated many forms of tissue motion, but is most commonly used to evaluate cardiac mechanics. Currently, motion analysis from cine DENSE images requires manually delineated anatomical structures. An automated analysis would improve measurement throughput, simplify data interpretation, and potentially access important physiological information during the MR exam. In this article, we present the first fully automated solution for the estimation of tissue motion and strain from 2D cine DENSE data. Results using both simulated and human cardiac cine DENSE data indicate good agreement between the automated algorithm and the standard semi-manual analysis method. PMID:22575669

  16. Las razones de la noche: cine mexicano actual

    OpenAIRE

    Luna, Andrés de

    2004-01-01

    nulo El cine mexicano tiene una historia que comienza con la llegada de los enviados de los Lumiére en 1896. Luego llegó la revolución en 1910 y la cinematografía recuperá la imagen de los caudillos y de las batallas. Una vez que concluye el movimiento armado, se da un cine mudo cargado de evasiones, que imita al cine italiano. En 1936 se forma la industria del cine nacional gracias a la fórmula sugerida por el éxito comercial de Allá en el rancho grande. Después vendrá la época de oro del...

  17. Fundamental Tongue Motions for Trumpet Playing: A Study Using Cine Magnetic Resonance Imaging (Cine MRI).

    Science.gov (United States)

    Furuhashi, Hiroko; Chikui, Toru; Inadomi, Daisuke; Shiraishi, Tomoko; Yoshiura, Kazunori

    2017-12-01

    Though the motions of structures outside the mouth in trumpet performance have been reported, the dynamics of intraoral structures remain unelucidated. This study explored the tongue's movement in trumpet playing using cine magnetic resonance imaging (cine MRI) and demonstrated the effects of intraoral anatomical structures on changes in pitch and dynamics. Cine MRI was applied to 18 trumpet players, who were divided into two groups (7 beginner, 11 advanced) based on their ability to play a certain high note. They were instructed to play a custom-made MRI-compatible simulated trumpet. Pitch-change tasks and dynamics-change tasks were assigned. The positions of the anatomical points and intraoral areas were identified on outlined images, and the changes associated with each task were evaluated. A forward and upward projection of the tongue was observed in the production of higher pitches, and there were no significant differences in all areas. In louder dynamics, a backward and downward bending of the tongue occurred, the tongue area became smaller (pcine MRI that certain tongue movements were associated with each task. Tongue protrusion in the production of higher pitch and bending in louder dynamics can be rationalized using acoustics theory and the movements of anatomical structures. These findings seem to be consistent regardless of the player's proficiency.

  18. Control of an X-ray cine radiography apparatus

    International Nuclear Information System (INIS)

    Nishio, K.

    1982-01-01

    This patent application describes an X-ray cine radiography apparatus comprising an X-ray tube, an image intensifier for converting the X-rays transmitted through an object into a visual image and a cine camera for picking up the visual image, a photomultiplier detects the brightness of the visual image to produce a brightness signal and a potentiometer detects the actual tube voltage of said X-ray tube. (author)

  19. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  20. Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Bomas, Bettina; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-12-01

    Improved real-time cardiac magnetic resonance (CMR) sequences have currently been introduced, but so far only limited practical experience exists. This study aimed at image reconstruction optimization and clinical validation of a new highly accelerated real-time cine SPARSE-SENSE sequence. Left ventricular (LV) short-axis stacks of a real-time free-breathing SPARSE-SENSE sequence with high spatiotemporal resolution and of a standard segmented cine SSFP sequence were acquired at 1.5 T in 11 volunteers and 15 patients. To determine the optimal iterations, all volunteers' SPARSE-SENSE images were reconstructed using 10-200 iterations, and contrast ratios, image entropies, and reconstruction times were assessed. Subsequently, the patients' SPARSE-SENSE images were reconstructed with the clinically optimal iterations. LV volumetric values were evaluated and compared between both sequences. Sufficient image quality and acceptable reconstruction times were achieved when using 80 iterations. Bland-Altman plots and Passing-Bablok regression showed good agreement for all volumetric parameters. 80 iterations are recommended for iterative SPARSE-SENSE image reconstruction in clinical routine. Real-time cine SPARSE-SENSE yielded comparable volumetric results as the current standard SSFP sequence. Due to its intrinsic low image acquisition times, real-time cine SPARSE-SENSE imaging with iterative image reconstruction seems to be an attractive alternative for LV function analysis. • A highly accelerated real-time CMR sequence using SPARSE-SENSE was evaluated. • SPARSE-SENSE allows free breathing in real-time cardiac cine imaging. • For clinically optimal SPARSE-SENSE image reconstruction, 80 iterations are recommended. • Real-time SPARSE-SENSE imaging yielded comparable volumetric results as the reference SSFP sequence. • The fast SPARSE-SENSE sequence is an attractive alternative to standard SSFP sequences.

  1. Experiences using the Fixin locking plate system for the stabilization of appendicular fractures in dogs: a clinical and radiographic retrospective assessment.

    Science.gov (United States)

    Nicetto, T; Petazzoni, M; Urizzi, A; Isola, M

    2013-01-01

    To retrospectively evaluate the stabilization of appendicular fractures in dogs using the Fixin locking plate system. Medical records and radiographs of dogs with fractures stabilized with the Fixin system in the period from May 2005 to September 2010 were reviewed. For each patient, data pertaining to signalment, the nature of the fracture, implants used, and evidence of fracture healing were recorded. The outcome and complications were determined from clinical and radiographic follow-up examinations. Limb function was evaluated between 40 days and 90 days postoperatively. Owners of pets with complications were contacted by phone for long-term follow-up. Eighty-two fractures in seventy-five dogs met the inclusion criteria for the study. Radiographic re-examinations were carried out between eight days to two years (median 60 days) following surgery. Seventy-three out of 82 fractures (89%) reached union without complications. Major complications were seen in six dogs (7%). Limb function was graded as 'normal' in 73/75 (97%) dogs and 'mild lameness' in 2/75 (3%) cases. Despite a modest complication rate, the Fixin locking bone plating system appears to be an acceptable choice of implant for the stabilization of appendicular fractures in dogs.

  2. El cine y el Estado mexicano

    Directory of Open Access Journals (Sweden)

    Eduardo De La Vega Alfaro

    2015-01-01

    Full Text Available La industria cinematográfica mexicana alcanzó su apogeo entre 1941-45 ha sido uno de los más fuertes y difundidos del continente gracias al apoyo que ha recibido de Hollywood. Su desarrollo dependió siempre, en mayor o menor grado, del apoyo de Estado, hasta lograr penetrar en los mercados de habla hispana. Hoy éste se repliega de su papel tradicional y la industria busca nuevos fórmulas de producción y distribución. En los último años la industria fílmica ha sentido nuevos efectos de la crisis producto de la competencia del video y el cierre de las salas de cine.

  3. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  4. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Brandt, Andrew; Louw, Brand; Dekker, Gerrit; Andronikou, Savvas; Wieselthaler, Nicki; Kilborn, Tracy; Bertelsman, Jessica; Dreyer, Catherine

    2007-01-01

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  5. Cine MRI of Tracheal Dynamics in Healthy Volunteers and Patients With Tracheobronchomalacia.

    Science.gov (United States)

    Ciet, Pierluigi; Boiselle, Phillip M; Heidinger, Benedikt; Andrinopoulou, Eleni-Rosalina; O'Donnel, Carl; Alsop, David C; Litmanovich, Diana E

    2017-10-01

    Bronchoscopy and MDCT are routinely used to assess tracheobronchomalacia (TBM). Recently, dynamic MRI (cine MRI) has been proposed as a radiation-free alternative to MDCT. In this study, we tested cine MRI assessment of airway dynamics during various breathing conditions and compared cine MRI and MDCT measurements in healthy volunteers and patients with suspected TBM. Cine MRI was found to be a technically feasible alternative to MDCT for assessing central airway dynamics.

  6. Las personas mayores a través del cine

    Directory of Open Access Journals (Sweden)

    José Ramón Martínez Riera

    Full Text Available Resumen: El presente artículo hace un recorrido por las diferentes etapas del envejecimiento y de la vida de las personas mayores a través del cine. El cine es un arte que transmite ideas a través de la narración de historias, mediante imágenes que impactan en el aspecto psicoemocional de las personas. El cine nos sitúa en escenarios donde se muestran las relaciones humanas, en contextos difíciles de reproducir, los cuales nos permiten explorar la esfera de los sentimientos frente a situaciones de salud-enfermedad, de ponerse en lugar del “otro”: de la persona que sueña, padece y sufre, de los profesionales que intervienen, de la familia que convive, cuida, sufre con el enfermo, de los amigos... Y entre esos escenarios, sin duda, se encuentra el proceso de envejecimiento y los diferentes factores que influyen en él. Y sin embargo no suele prestársele excesiva atención a la aportación que el cine ha realizado y realiza como elemento de reflexión, análisis, debate y aprendizaje, más allá del mero entretenimiento en el que muchas veces se enmarca el cine. Pero, ¿cómo ha tratado el cine a las personas mayores? ¿cómo aborda las interrelaciones de las personas mayores con su entorno, su familia, su proceso de salud-enfermedad, sus miedos, sus emociones? ¿Trata igual a las personas mayores con independencia de su género? Y lo que puede ser más interesante, ¿contribuye el cine a mitigar o eliminar los tópicos y estereotipos existentes en el imaginario común en torno a las personas mayores?

  7. Dobutamine cine magnetic resonance imaging after myocardial infarction

    International Nuclear Information System (INIS)

    Giovagnoni, A.; Ligabue, G.; Romagnoli, R.; Reggio Emilia Univ., Reggio Emilia; Rossi, R.; Muia, N.; Modena, M.G.; Reggio Emilia Univ.

    1999-01-01

    Dobutamine Cine MRI is a new diagnostic imaging technique in the pretreatment (revascularization) assessment of myocardial infarction patients. In this issue are reported the result of a comparative study of the diagnostic yield of dobutamine Cine MRI with that of stress echocardiography in the assessment of viable myocardium. A new method for analysis of Cine MR images, employing digital subtraction, aimed at decreasing subjectivity in the quantitative assessment of myocardial wall thickening. Twenty-six patients (21 men and 5 women) with a history of myocardial infarction who were scheduled for revascularization were submitted to stress echocardiography and dobutamine Cine MRI to evaluate contractile recovery of the segments considered akinetic or hypo kinetic at baseline echocardiography. Dobutamine was administered in growing doses (5, 10, 15γ/kg/min). 16 segments of the left ventricle in each patient were considered. In the 416 segments studied, it was found that 307 normo kinetic, 64 scarred and 45 viable segments with stress echocardiography, versus 302 normo kinetic, 83 scarred and 31 viable segments with dobutamine MRI. Three months after revascularization 15 patients were examined to check contractile recovery of the segments considered as viable. Echocardiography had 79% sensitivity and 97% specificity, while Cine MRI had 96% and 86%, respectively. In patients with anteroseptal wall myocardial infarction stress echocardiography had 75% sensitivity and 97% specificity. Echocardiography permits to distinguish viable myocardium and scarred myocardial tissue with good sensitivity and specificity, but Cine MRI performs better. Cine MRI has much higher sensitivity than stress echocardiography and thus makes the technique of choice to evaluate viable myocardium in these sites. The digital subtraction technique is as accurate as manual measurements, but reduces the error rate and permits quicker evaluation, particularly in subendocardial thickening [it

  8. Clinical, Radiographic and Microbiological Evaluation of High Level Laser Therapy, a New Photodynamic Therapy Protocol, in Peri-Implantitis Treatment; a Pilot Experience

    Directory of Open Access Journals (Sweden)

    Gianluigi Caccianiga

    2016-01-01

    Full Text Available Aim. Endosseous implants are widely used to replace missing teeth but mucositis and peri-implantitis are the most frequent long-term complications related with dental implants. Removing all bacterial deposits on contaminated implant surface is very difficult due to implant surface morphology. The aim of this study was to evaluate the bactericidal potential of photodynamic therapy by using a new high level laser irradiation protocol associated with hydrogen peroxide in peri-implantitis. Materials and Methods. 10 patients affected by peri-implantitis were selected for this study. Medical history, photographic documentation, periodontal examination, and periapical radiographs were collected at baseline and 6 months after surgery. Microbiological analysis was performed with PCR Real Time. Each patient underwent nonsurgical periodontal therapy and surgery combined with photodynamic therapy according to High Level Laser Therapy protocol. Results. All peri-implant pockets were treated successfully, without having any complication and not showing significant differences in results. All clinical parameters showed an improvement, with a decrease of Plaque Index (average decrease of 65%, range 23–86%, bleeding on probing (average decrease of 66%, range 26–80%, and probing depth (average decrease of 1,6 mm, range 0,46–2,6 mm. Periapical radiographs at 6 months after surgery showed a complete radiographic filling of peri-implant defect around implants treated. Results showed a decrease of total bacterial count and of all bacterial species, except for Eikenella corrodens, 6 months after surgery. Conclusion. Photodynamic therapy using HLLT appears to be a good adjunct to surgical treatment of peri-implantitis.

  9. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  10. ConCERNed for Humanity and Cine Club

    CERN Multimedia

    ConCERNed for Humanity and Cine Club

    2012-01-01

      Thursday 26 April 2012 at 20:00 CERN Council Chamber Sicko By Michael Moore (USA, 2007) 123 min, original version English; French subtitles. Documentary look at health care in the United States as provided by profit-oriented health maintenance organizations (HMOs) compared to free, universal care in Canada, the U.K., and France. Moore contrasts U.S. media reports on Canadian care with the experiences of Canadians in hospitals and clinics there. He interviews patients and doctors in the U.K. about cost, quality, and salaries. He examines why Nixon promoted HMOs in 1971, and why the Clintons’ reform effort failed in the 1990s. He talks to U.S. ex-pats in Paris about French services, and he takes three 9/11 clean-up volunteers, who developed respiratory problems, to Cuba for care. He asks of Americans, “Who are we?” Organisation : ConCERNed for Humanity Club and CERN CineClub Projection from DVD – entrance free – for info: http://cern.ch/C...

  11. Thursday Programme of CineGlobe Festival 2015

    CERN Multimedia

    Cugini, Pavel

    2015-01-01

    The CineGlobe Programme on Thursday 26th March 2015 counted with two short-films inspired by science sessions, two workshops on the 360 degree dome, and a special evening show in collaboration with the Mapping Festival, to celebrate the UNESCO Year of Light. The evening open with Diego Blas, CERN theorist, talking about Light, Einstein and the LHC to celebrate the UNESCO International Year of Light. Followed by a performance by the artist YRO_EILE_18. The artist Yro presents Eile, a live installation performance where light, sound, and cinema converge to tell a timeless story. EILE is a live cinema performance, in which yro makes live sound and images with a camera, some microphones and small objects like stones, balls, bits of paper and string.These materials allow him to create videos and sound, which aesthetics are close to abstract cinema and object theater assembled, sampled and grinded . The process is part of the staging itself as well as the film that results. Indescribable Eile is lived as an experie...

  12. High speed cine film studies of plasma behaviour and plasma surface interactions in tokamaks

    International Nuclear Information System (INIS)

    Goodall, D.H.J.

    1982-01-01

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions. Several workers have filmed discharges in tokamaks including ASDEX, DITE, DIVA, ISX, JFT2, TFR and PLT. These films are discussed and examples given of the observed phenomena which include plasma limiter interactions, diverted discharges, disruptions, magnetic islands and moving glowing objects often known as 'UFOs'. Examples of plasma structures in ASDEX and DITE not previously published are also given. The paper also reports experiments in DITE to determine the origin of UFOs. (orig.)

  13. High speed cine film studies of plasma behaviour and plasma surface interactions in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Goodall, D.H.J. (Euratom/UKAEA Fusion Association, Abingdon (UK). Culham Lab.)

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions. Several workers have filmed discharges in tokamaks including ASDEX, DITE, DIVA, ISX, JFT2, TFR and PLT. These films are discussed and examples given of the observed phenomena which include plasma limiter interactions, diverted discharges, disruptions, magnetic islands and moving glowing objects often known as 'UFOs'. Examples of plasma structures in ASDEX and DITE not previously published are also given. The paper also reports experiments in DITE to determine the origin of UFOs.

  14. Image processing in cine-scintigraphy. Organization of the CINE 200 system

    International Nuclear Information System (INIS)

    Tournier, E.; Axelrad, C.; Monge, J.; Beccia, A.; Bouvier, A.

    1975-01-01

    The CINE 200 system, although using a small computer to reduce costs, is shown to be a highly efficient instrument for the processing of scintigraphic images. This was achieved by creating an acquisition and display system branched directly onto the memory, reducing the processing times by the writing of fast micro-programmes, and cutting down the place occupied by the programmes in the live memory by a good organization of these programmes. This internal organization of the system, the insertion and role of the programmes, the data organization and the working procedure are described briefly [fr

  15. El cine como reivindicación de la memoria individual y colectiva. Directoras húngaras del periodo comunista

    OpenAIRE

    Cruzado Rodríguez, Ángeles

    2012-01-01

    This article takes a look at the most prominent women filmmakers of communist Hungary, emphasising both their common features and specificities, in order to highlight their contribution to Hungarian film history. In general, they are transgressive filmmakers, having broken the conventions established by the communist regime and tried to offer a new vision of history, based on their own experience.

    El artículo realiza un acercamiento a las directoras de cine más relevantes d...

  16. Cine e historia reciente de la educación española relato de una experiencia valiosa para la formación de los educadores. //Cinema and recent history of the Spanish education Story of a valuable experience for teacher training.

    Directory of Open Access Journals (Sweden)

    Virginia Guichot Reina

    2014-06-01

    Full Text Available (ES Presentamos nuestro proyecto de innovación Cine y memoria oral: dos grandes recursos didácticos para el estudio del pasado educativo reciente, desarrollado en la Facultad de Ciencias de la Educación de la Universidad de Sevilla con estudiantes de la asignatura “Política y Legislación Educativas” de quinto de Pedagogía. En él, se utilizan diferentes mecanismos para hacer más atractiva la materia al alumnado como la creación de una página web desde la que, además de acceder a una película seleccionada para estudiar un determinado período educativo, se pueden realizar diferentes actividades que conllevan consulta de documentos escritos de diversa índole, escucha de entrevistas a personajes relevantes para conocer de primera mano la educación de cierta época, visionado de carteles y exposiciones de material didáctico de dicho momento histó- rico, etc. // (EN We show the Project Cinema and Oral Memory: two great resources for the study about the educational contemporary past developed with students of the last year in the degree of Pedagogy in the University of Seville. This includes the use of films as a resource to work on the History of Education in Spain. In order to make the content concerning “Politics and Educational Legislation” more appealing to our students we have used different mechanisms by introducing innovative resources such as the creation of a web site. Here you can see the film which has been chosen to be studied in a specific educational period and you can consult different types of written documents, and listen to interviews of important people. You can also know from first hand experience the education of a specific historical moment, seeing posters and school objects from those years.

  17. Interpretation of panoramic radiographs.

    Science.gov (United States)

    Perschbacher, Susanne

    2012-03-01

    Panoramic radiography has become a commonly used imaging modality in dental practice and can be a valuable diagnostic tool in the dentist's armamentarium. However, the panoramic image is a complex projection of the jaws with multiple superimpositions and distortions which may be exacerbated by technical errors in image acquisition. Furthermore, the panoramic radiograph depicts numerous anatomic structures outside of the jaws which may create additional interpretation challenges. Successful interpretation of panoramic radiographs begins with an understanding of the normal anatomy of the head and neck and how it is depicted in this image type. This article will describe how osseous structures, soft tissues, air spaces and ghost shadows contribute to the final panoramic image. A systematic and repeated approach to examining panoramic radiographs, which is recommended to ensure that critical findings are not overlooked, is also outlined. Examples of challenging interpretations, including variations of anatomy, artefacts and disease, are presented to illustrate these concepts. © 2012 Australian Dental Association.

  18. Interactive radiographic image retrieval system.

    Science.gov (United States)

    Kundu, Malay Kumar; Chowdhury, Manish; Das, Sudeb

    2017-02-01

    Content based medical image retrieval (CBMIR) systems enable fast diagnosis through quantitative assessment of the visual information and is an active research topic over the past few decades. Most of the state-of-the-art CBMIR systems suffer from various problems: computationally expensive due to the usage of high dimensional feature vectors and complex classifier/clustering schemes. Inability to properly handle the "semantic gap" and the high intra-class versus inter-class variability problem of the medical image database (like radiographic image database). This yields an exigent demand for developing highly effective and computationally efficient retrieval system. We propose a novel interactive two-stage CBMIR system for diverse collection of medical radiographic images. Initially, Pulse Coupled Neural Network based shape features are used to find out the most probable (similar) image classes using a novel "similarity positional score" mechanism. This is followed by retrieval using Non-subsampled Contourlet Transform based texture features considering only the images of the pre-identified classes. Maximal information compression index is used for unsupervised feature selection to achieve better results. To reduce the semantic gap problem, the proposed system uses a novel fuzzy index based relevance feedback mechanism by incorporating subjectivity of human perception in an analytic manner. Extensive experiments were carried out to evaluate the effectiveness of the proposed CBMIR system on a subset of Image Retrieval in Medical Applications (IRMA)-2009 database consisting of 10,902 labeled radiographic images of 57 different modalities. We obtained overall average precision of around 98% after only 2-3 iterations of relevance feedback mechanism. We assessed the results by comparisons with some of the state-of-the-art CBMIR systems for radiographic images. Unlike most of the existing CBMIR systems, in the proposed two-stage hierarchical framework, main importance

  19. Cine-MRI swallowing evaluation after tongue reconstruction

    International Nuclear Information System (INIS)

    Hartl, Dana M.; Kolb, Frederic; Bretagne, Evelyne; Bidault, Francois; Sigal, Robert

    2010-01-01

    Objective: To determine the feasibility of cine-MRI for non-invasive swallowing evaluation after surgery for lingual carcinoma with reconstruction using microvascular free flaps. Methods: Ten patients with stage IV carcinoma of the mobile tongue and/or tongue base treated by surgical resection and reconstruction with a free flap were evaluated after an average of 4.3 years (range: 1.5-11 years), using cine-MRI in 'single-shot fast spin echo' (SSFSE) mode. Fiberoptic laryngoscopy of swallowing was performed before MRI to detect aspiration. The tolerance and ability to complete the exam were noted. The mobilities of the oral and pharyngeal structures visualized were evaluated as normal, reduced or increased. Results: Cine-MRI was well tolerated in all cases; 'dry' swallow was performed for the 2 patients with clinical aspiration. Tongue base-pharyngeal wall contact was observed in 5 cases. An increased anterior tongue recoil, increased mandibular recoil, increased posterior oropharyngeal wall advancement and an increased laryngeal elevation were observed in 4 cases. One case of a passive 'slide' mechanism was observed. Conclusions: Cine-MRI is a safe, non-invasive technique for the evaluation of the mobility of oral and oropharyngeal structures after free-flap reconstruction of the tongue. For selected cases, it may be complementary to clinical examination for evaluation of dysphagia after surgery and free-flap reconstruction. Further technical advances will be necessary before cine-MRI can replace videofluoroscopy, however.

  20. Real-time automatic fiducial marker tracking in low contrast cine-MV images

    International Nuclear Information System (INIS)

    Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang; Liou, Shu-Cheng; Nath, Ravinder; Liu Wu

    2013-01-01

    Purpose: To develop a real-time automatic method for tracking implanted radiographic markers in low-contrast cine-MV patient images used in image-guided radiation therapy (IGRT). Methods: Intrafraction motion tracking using radiotherapy beam-line MV images have gained some attention recently in IGRT because no additional imaging dose is introduced. However, MV images have much lower contrast than kV images, therefore a robust and automatic algorithm for marker detection in MV images is a prerequisite. Previous marker detection methods are all based on template matching or its derivatives. Template matching needs to match object shape that changes significantly for different implantation and projection angle. While these methods require a large number of templates to cover various situations, they are often forced to use a smaller number of templates to reduce the computation load because their methods all require exhaustive search in the region of interest. The authors solve this problem by synergetic use of modern but well-tested computer vision and artificial intelligence techniques; specifically the authors detect implanted markers utilizing discriminant analysis for initialization and use mean-shift feature space analysis for sequential tracking. This novel approach avoids exhaustive search by exploiting the temporal correlation between consecutive frames and makes it possible to perform more sophisticated detection at the beginning to improve the accuracy, followed by ultrafast sequential tracking after the initialization. The method was evaluated and validated using 1149 cine-MV images from two prostate IGRT patients and compared with manual marker detection results from six researchers. The average of the manual detection results is considered as the ground truth for comparisons. Results: The average root-mean-square errors of our real-time automatic tracking method from the ground truth are 1.9 and 2.1 pixels for the two patients (0.26 mm/pixel). The

  1. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  2. Emotional Intelligence Throughout the Lifecycle of Australian Radiographers.

    Science.gov (United States)

    Lewis, Sarah Jayne; Eccles, Grace Rose; Mackay, Stuart James; Robinson, John

    2017-09-01

    To measure global and domain trait emotional intelligence (EI) throughout the professional lifecycle of Australian radiographers and report the trends. A combination retrospective and prospective cross-sectional multiple-cohort study using the Trait Emotional Intelligence Questionnaire Short Form (TEIQue-SF) was designed to collect global and domain trait EI scores of several populations, including radiography students (n = 95), inexperienced radiographers (0-5 years' experience; n = 94), experienced radiographers (≥ 6 years' experience; n = 451), chief radiographers (n = 107), clinical educators (n = 24), application specialists (n = 24), and radiographers working in education (n = 15). Mean EI scores were calculated and statistical tests were performed to determine whether significant differences existed among the groups. Statistically significant differences were found among populations for global EI and the domains of self-control and well-being, with students demonstrating consistently lower scores than qualified radiographers ( P ≥ .001). Chief radiographers demonstrated higher scores for well-being than inexperienced radiographers, radiographers working in education, and students ( P < .001). Global EI scores increased steadily throughout the professional lifecycle of Australian radiographers, plateauing at 10 years of clinical experience. Chief radiographers demonstrated the highest scores for well-being, which is consistent with prior research acknowledging the importance of EI in organizational leadership. Students demonstrated lower EI scores likely because they are at the beginning of their careers and might not yet perceive themselves as confident or successful. Higher EI scores are expected in normal career advancement, plateauing at about 10 years of clinical experience. A statistically significant difference exists between global and domain trait EI scores throughout the professional lifecycle of Australian radiologic technologists. Global trait

  3. MUJER Y CINE EN AMÉRICA LATINA: PROYECTANDO UNA VISIÓN ALTERNATIVA DE LA NACIÓN

    OpenAIRE

    Rosa-Linda Fregoso

    2016-01-01

    Al explorar la relación entre cine de mujeres y cines latinoamericanos, este artículo interroga las categorías de cine nacional, cine latinoamericano y cine de mujeres con el fin de superar lógicas geopolíticas, de idiomas, colonialidad, y las lógicas industriales del mercado que han creado esas categorías. Partiendo de interrogantes como qué modelo de análisis feminista del cine es adecuado para articular las perspectivas de mujeres en las nuevas formaciones del cine mundial, propongo la uti...

  4. Perturbando mentes: el cine como herramienta de transformación personal

    OpenAIRE

    Rodríguez Hoyos, Carlos; Manrique Solana, Rafael

    2015-01-01

    Resumen: En este artículo se analizan e interrogan las potencialidades didácticas del cine en los espacios de educación superior. Para ello, se revisan diversas propuestas de integración del cine en las aulas universitarias que han sido sistematizadas en dos grandes tradiciones: la educación para el cine y la educación con el cine. Finalmente, se realiza una propuesta de educación por el cine, que trata de reconocer y desarrollar el potencial de este medio para llevar a cabo transformaciones ...

  5. El cine indio, a la conquista de Hispanoamérica

    Directory of Open Access Journals (Sweden)

    María Helena Barrera Agarwal

    2007-03-01

    Full Text Available Trata sobre el cine de la India y hace una aclaración: cine indio y no cine hindú, que es una religión. Confirma que existen indicios de una confluencia entre el cine indio y el público hispanoamericano. Con más de 1.300 películas por año el cine indio es el único sector del séptimo arte que, a nivel mundial, ha sabido resistir los embates de Hollywood.

  6. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  7. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  8. Learner concerns of radiographers

    International Nuclear Information System (INIS)

    Popli, Pawan Kumar

    1998-01-01

    Today radiology is fastest developing branch of medical sciences. Most of the radiographers are trained in old fashion, most of training institutes lack proper equipment. It not only affects their career but radiological quality at large. For this purpose it is necessary to find out educational possibilities and needs of group. Therefore this project was taken up

  9. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  10. Intracardiac flow patterns studied by cine MR flow imaging

    International Nuclear Information System (INIS)

    Underwood, S.R.; Firmin, D.N.; Klipstein, R.H.; Rees, R.S.O.; Longmore, D.B.

    1986-01-01

    Velocity mapping by means of cine-MR imaging allows accurate measurement of velocity and flow within the cardiovascular system. A cine display and color coding simplify interpretation. The author have used the technique in a variety of patients to illustrate its potential. Velocity mapping in coronary artery by pass grafts in six patients provided a measure of graft function. Coronary artery velocities were measured in three subjects. Flow was measured through defects in the atrial septum, the ventricular septum, and a Gerbode defect. Velocity was reduced distal to coarctation of the aorta and was increased at the level of a partial venous occlusion by thrombosis. In a patient with isomerism, velocity mapping in the central vessels aided interpretation. Cine-MR imaging velocity mapping combined with conventional imaging yields important functional information on the cardiovascular system

  11. Sexualidad violenta en el cine de Kim Ki-duk

    Directory of Open Access Journals (Sweden)

    Daniel Muñoz Ruiz

    2011-07-01

    Full Text Available En sus más de 110 años de vida el cine ha representado la sexualidad humana en todas sus modalidades y desde los más variados puntos de vista. El cine de Kim Ki-duk ha sorprendido y escandalizado al público por su crudeza y, a veces, excesiva violencia. El director surcoreano ha explorado a lo largo de su filmografía el tema del sexo siempre desde puntos de vista dramáticos y hasta truculentos. En sus películas la mayoría de las relaciones sexuales carecen de amor y afecto. Nunca son placenteras. La violación, la prostitución, la violencia de género y las frustraciones sexuales son temas recurrentes en su cine.

  12. Magnetic resonance (MR) cine imaging of the human heart

    International Nuclear Information System (INIS)

    Waterton, J.C.

    1985-01-01

    A novel approach has been developed for MR cine imaging of the human heart by a modified ECG-gated 2DFT method. A pulse sequence has been devised to minimise the effects of saturation which can be anticipated in sequences that require rapid pulsing. Five frames are produced at the same anatomical level at predetermined intervals during the cardiac cycle. The total time taken to achieve this data is 8 minutes. Additional frames can be interleaved by repeating the sequence with an ECG-gated delay. The anatomical sections, which can be in any orthogonal plane, are then displayed as a cine loop. Cine display in the coronal plane has been used to examine 10 volunteers and 12 patients. In addition to the morphological feature displayed in single slice ECG-gated imaging, areas of dyskinesia can be detected and subjective estimates have been made of left ventricular function. (author)

  13. Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function

    International Nuclear Information System (INIS)

    Wintersperger, Bernd J.; Dietrich, Olaf; Huber, Armin; Reiser, Maximilian F.; Schoenberg, Stefan O.; Sincleair, Spencer; Runge, Val M.

    2007-01-01

    The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach (all r 2 =0.99, P<0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (κ=0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter (∝75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution. (orig.)

  14. Functional radiographs of the craniocervical region and cervical spine

    International Nuclear Information System (INIS)

    Mayer, E.T.; Auberger, T.; Herrmann, G.; Pfaffenrath, W.; Poellmann, W.

    1985-01-01

    Disabilities of the articulation of the head and cervical spine can often be detected only by exact measurement of functional radiographs. From two radiographs, one in flexion and one in extension, not only can the total mobility of the head be measured, but also the mobility of the individual articulations can be evaluated by taking exact measurements of the position of each vertebra. A method for semi-automatic measuring of such pairs of radiographs is presented. Edges and structures of the bones that are clearly visible in both radiographs are digitized on a graphict tablet. Then, by computer program, each vertebra of the first radiograph is shifted and rotated until it fits best to the respective vertebra of the second radiograph. Thus, for each articulation, the mobility angle and the location of the mobility axis relative to the adjacent vertebra, can be computed. First experiences with this method are presented

  15. Bailes de pareja en el cine musical de Hollywood

    OpenAIRE

    Moreno Cardenal, Luisa

    2011-01-01

    El cine de Hollywood, industria cultural, potente medio de comunicación de masas, fuente de educación sentimental, creador de modas y corrientes estéticas, abordó la articulación de la diferencia sexual y sus conflictos con especial plasticidad en el terreno del musical. Muchas películas musicales de las primeras décadas del cine sonoro –y algunas más cercanas en el tiempo- incluyeron coreografías potencialmente exportables a las salas de baile, retroalimentándose así ambos textos, películas ...

  16. Cine español en el disparadero [book review

    OpenAIRE

    Aranzubia, Asier

    2004-01-01

    Este artículo reseña: Castro de Paz, J. L. Un cinema herido. Los turbios años cuarenta en el cine español (1939-1950). Barcelona : Paidós, 2002. Jolivet, A.M. La pantalla subliminal. Marcelino Pan y Vino según Vajda. Valencia : IVAC-La Filmoteca, 2003. Heredero, C.F., Monterde, J. E. (eds.). Los "Nuevos cines" en España. Ilusiones y desencantos de los años sesenta. Valencia : IVAC-La Filmoteca : Festival Internacional de Gijón, 2003

  17. Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia.

    Science.gov (United States)

    Bassett, Elwin C; Kholmovski, Eugene G; Wilson, Brent D; DiBella, Edward V R; Dosdall, Derek J; Ranjan, Ravi; McGann, Christopher J; Kim, Daniel

    2014-02-01

    Electrocardiogram (ECG)-gated breath-hold cine MRI is considered to be the gold standard test for the assessment of cardiac function. However, it may fail in patients with arrhythmia, impaired breath-hold capacity and poor ECG gating. Although ungated real-time cine MRI may mitigate these problems, commercially available real-time cine MRI pulse sequences using parallel imaging typically yield relatively poor spatiotemporal resolution because of their low image acquisition efficiency. As an extension of our previous work, the purpose of this study was to evaluate the diagnostic quality and accuracy of eight-fold-accelerated real-time cine MRI with compressed sensing (CS) for the quantification of cardiac function in tachycardia, where it is challenging for real-time cine MRI to provide sufficient spatiotemporal resolution. We evaluated the performances of eight-fold-accelerated cine MRI with CS, three-fold-accelerated real-time cine MRI with temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) and ECG-gated breath-hold cine MRI in 21 large animals with tachycardia (mean heart rate, 104 beats per minute) at 3T. For each cine MRI method, two expert readers evaluated the diagnostic quality in four categories (image quality, temporal fidelity of wall motion, artifacts and apparent noise) using a Likert scale (1-5, worst to best). One reader evaluated the left ventricular functional parameters. The diagnostic quality scores were significantly different between the three cine pulse sequences, except for the artifact level between CS and TGRAPPA real-time cine MRI. Both ECG-gated breath-hold cine MRI and eight-fold accelerated real-time cine MRI yielded all four scores of ≥ 3.0 (acceptable), whereas three-fold-accelerated real-time cine MRI yielded all scores below 3.0, except for artifact (3.0). The left ventricular ejection fraction (LVEF) measurements agreed better between ECG-gated cine MRI and eight-fold-accelerated real-time cine MRI

  18. Verification of respiratory-gated radiotherapy with new real-time tumour-tracking radiotherapy system using cine EPID images and a log file.

    Science.gov (United States)

    Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko

    2017-02-21

    A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were  ⩽3 mm and  ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.

  19. Verification of respiratory-gated radiotherapy with new real-time tumour-tracking radiotherapy system using cine EPID images and a log file

    Science.gov (United States)

    Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko

    2017-02-01

    A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were  ⩽3 mm and  ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.

  20. Comparison of radiographic technique by computer simulation

    International Nuclear Information System (INIS)

    Brochi, M.A.C.; Ghilardi Neto, T.

    1989-01-01

    A computational algorithm to compare radiographic techniques (KVp, mAs and filters) is developed based in the fixation of parameters that defines the images, such as optical density and constrast. Before the experience, the results were used in a radiography of thorax. (author) [pt

  1. Effects of rotation radiographic dimensions of metacarpals

    International Nuclear Information System (INIS)

    Armes, F.M.; Horsman, A.; Bentley, H.B.

    1979-01-01

    An experiment is described which shows that small rotations of metacarpals about their long axis produce small systematic changes in the cortical dimensions as measured by radiographic morphometry. The effect is of no significance in cross-sectional studies but is an important source of error in sequential studies. (author)

  2. El devenir del cine musical de Hollywood

    Directory of Open Access Journals (Sweden)

    Moreno Cardenal, Luisa

    2015-08-01

    Full Text Available Film genres which were defined and developed by Hollywood during the early decades of the 20th century are no longer the same: a hundred years after they were first born, they are undergoing profound changes and a thorough revision. As a result, new sub-genres are emerging and others that were once essential to the identity of film as a mass phenomenon are becoming blurred. One such film genre on the verge of extinction is the musical. This paper briefly traces out the way musicals developed, from their beginnings through to the early years of the 21st century, enabling the keys to their success and their decline to be identified. Some major productions, with outstanding soundtracks or choreography building an interaction between the leading roles, will be especially examined.Los géneros cinematográficos delimitados por la industria de Hollywood a lo largo de las primeras décadas del siglo XX viven, cien años después, un proceso de revisión y metamorfosis que da como resultado el nacimiento de nuevos subgéneros y el desdibujamiento de otros que, durante décadas, tuvieron una entidad inequívoca e imprescindible para entender el cine como espectáculo y fenómeno de masas. Uno de esos géneros en periodo de extinción es el musical. Mostramos aquí un somero recorrido por el devenir del género desde su nacimiento hasta comienzos del siglo XXI, tratando de localizar las claves de su éxito y de su declive y fijándonos especialmente en algunos títulos importantes que cuentan, además de con maravillosas bandas sonoras, con números de baile escenificados para construir la dialéctica entre sus protagonistas.

  3. Osteology for radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Shillingford, C.

    1985-01-01

    Radiographers need a detailed knowledge of the skeleton and it is not easy to find the correct level of information in the textbooks available to date. This book aims to fill this void. Descriptions of individual bones are logical and easy to follow, and common examples of pathology are included for each bone. Self-assessment questions are given at the end of each paper to enable students to assess their acquired knowledge and to facilitate private study.

  4. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  5. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  6. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  7. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  8. New respiratory gating technique for whole heart cine imaging: integration of a navigator slice in steady state free precession sequences.

    Science.gov (United States)

    Uribe, Sergio; Tejos, Cristian; Razavi, Reza; Schaeffter, Tobias

    2011-07-01

    To evaluate the performance of a slice navigator sequence integrated into a b-SSFP sequence for obtaining real time respiratory self-gated whole heart cine imaging. In this work, we present a novel and robust approach for respiratory motion detection by integrating a slice navigator sequence into a balanced steady state free precession (b-SSFP) sequence, while maintaining the steady state. The slice navigator sequence is integrated into consecutive repetition times (TRs) of a b-SSFP sequence to excite and read out a navigator slice. We performed several phantom experiments to test the performance of the slice navigator sequence. Additionally, the method was evaluated in five volunteers and compared with breathing signals obtained from conventional pencil beam navigator sequence. Finally, the navigator slice was used to obtain whole heart MR cine images. The breathing signals detected by the proposed method showed an excellent agreement with those obtained from pencil beam navigators. Moreover, the technique was capable of removing respiratory motion artifacts with minimal distortion of the steady state. Image quality comparison showed a statistical significant improvement from a quality score of 2.1 obtained by the nonrespiratory gated images, compared to a quality score of 3.4 obtained by the respiratory gated images. This novel method represents a robust approach to estimate breathing motion during SSFP imaging. The technique was successfully applied to acquire whole heart artifact-free cine images. Copyright © 2011 Wiley-Liss, Inc.

  9. Marruecos: 44 años de cine colonial

    Directory of Open Access Journals (Sweden)

    Lic. Mohamed Lemrini

    2000-01-01

    Full Text Available Haciendo un poco de historia, el Norte de África conoció una escalada militar colonizadora y un gran interés por las grandes potencias europeas del momento a finales del siglo XIX, coincidiendo precisamente con el nacimiento del cine.

  10. Some Semantic Properties of Romanian Interrogatives: "Care" and "Cine."

    Science.gov (United States)

    Vasiliu, E.

    The aim of this paper is to account for some semantic properties of Romanian interrogatives "ce" and "cine" by establishing some definite correlations between various contextual restrictions governing the use of these interrogative particles and the "meaning" which might be assigned to each of these particles in any…

  11. Highly-Accelerated Real-Time Cardiac Cine MRI Using k-t SPARSE-SENSE

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B.; Lim, Ruth P.; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward VR.; Sodickson, Daniel K.; Otazo, Ricardo; Kim, Daniel

    2012-01-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (~2.5mm × 2.5mm) and temporal resolution (~40ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular (LV) function. In this work, we present an 8-fold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our 8-fold accelerated real-time cine MRI produced significantly worse qualitative grades (1–5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both 8-fold accelerated real-time cine and breath-hold cine MRI yielded comparable LV function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. PMID:22887290

  12. Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B; Lim, Ruth P; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward V R; Sodickson, Daniel K; Otazo, Ricardo; Kim, Daniel

    2013-07-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm(2)) and temporal resolution (∼40 ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our eightfold accelerated real-time cine MRI produced significantly worse qualitative grades (1-5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real-time cine and breath-hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. Copyright © 2012 Wiley Periodicals, Inc.

  13. Cine comercial y conocimiento sobre el proceso de morir

    Directory of Open Access Journals (Sweden)

    María Campo-Redondo

    2009-05-01

    Full Text Available El cine como recurso tecnológico para generar conocimientos ha empezado a dar sus frutos. En este artículose presenta los resultados de la inserción del cine en la generación de conocimientos bajo dos vertientes: una teórica,discutiendo la intersección entre la era de la tecnología digital y el modo de crear conocimiento propio de esta era, yotra empírica, describiendo una propuesta de utilización didáctica del “cine comercial” con el fin de analizar el significadode la muerte. Así, el artículo se divide en cinco sub-partes. En primer lugar, se contextualiza la era de la tecnologíadigital en la creación de conocimiento. En segundo lugar, se resalta las ventajas de utilizar el cine en la transmisión deconocimiento, en especial aquel que es difícil de adquirir por la vía experiencial. En tercer lugar, se describe la metodologíautilizada en la aplicación de una propuesta didáctica llevada a cabo con estudiantes de una cátedra de Psicologíadel Desarrollo, en la que la película “Antes de Partir” fue el estímulo sobre el cual se organizó la discusión relacionadacon el fin del ciclo la vida de los seres humanos. En cuarto lugar, se resume los hallazgos más importantes sobre estaexperiencia de investigación, al combinar el cine con aspectos teóricos relacionados con la conceptualización de lamuerte. Por último, se destaca las virtudes de la metodología empleada.

  14. Self-gated fat-suppressed cardiac cine MRI.

    Science.gov (United States)

    Ingle, R Reeve; Santos, Juan M; Overall, William R; McConnell, Michael V; Hu, Bob S; Nishimura, Dwight G

    2015-05-01

    To develop a self-gated alternating repetition time balanced steady-state free precession (ATR-SSFP) pulse sequence for fat-suppressed cardiac cine imaging. Cardiac gating is computed retrospectively using acquired magnetic resonance self-gating data, enabling cine imaging without the need for electrocardiogram (ECG) gating. Modification of the slice-select rephasing gradients of an ATR-SSFP sequence enables the acquisition of a one-dimensional self-gating readout during the unused short repetition time (TR). Self-gating readouts are acquired during every TR of segmented, breath-held cardiac scans. A template-matching algorithm is designed to compute cardiac trigger points from the self-gating signals, and these trigger points are used for retrospective cine reconstruction. The proposed approach is compared with ECG-gated ATR-SSFP and balanced steady-state free precession in 10 volunteers and five patients. The difference of ECG and self-gating trigger times has a variability of 13 ± 11 ms (mean ± SD). Qualitative reviewer scoring and ranking indicate no statistically significant differences (P > 0.05) between self-gated and ECG-gated ATR-SSFP images. Quantitative blood-myocardial border sharpness is not significantly different among self-gated ATR-SSFP ( 0.61±0.15 mm -1), ECG-gated ATR-SSFP ( 0.61±0.15 mm -1), or conventional ECG-gated balanced steady-state free precession cine MRI ( 0.59±0.15 mm -1). The proposed self-gated ATR-SSFP sequence enables fat-suppressed cardiac cine imaging at 1.5 T without the need for ECG gating and without decreasing the imaging efficiency of ATR-SSFP. © 2014 Wiley Periodicals, Inc.

  15. Cine interactivo como estrategia de intervención grupal

    Directory of Open Access Journals (Sweden)

    Paola Lauretti

    2009-05-01

    Full Text Available Utilizando el concepto de cine interactivo como agente motor de la relación inter e intra personal, presentamosuna experiencia con un grupo de adultos, con la finalidad de establecer el valor del cine como un recurso útil para laintervención grupal. El método de trabajo descriptivo se desarrolló en varias etapas: 1 aplicación del CuestionarioExploración de Necesidades (CEN del cual se extrajeron los principales temas a tratar; 2 selección, por parte delequipo de investigación, de aquellas películas que mejor se adaptaban a las necesidades detectadas; 3 aplicación delCuestionario Actitud frente al Cine (CAC para sus analizar su actitud antes de iniciar la experiencia; 4 proyecciónde las películas seleccionadas; 5 re aplicación del CAC dos meses después de culminado el proceso, para analizar loscambios operados con relación al cine. Los temas trabajados fueron relación de pareja y relaciones padres-hijos bajola utilización del modelo CAPAS el cual promueve el análisis de las situaciones planteadas en los siguientes pasos: C:comentario general del contenido; A: análisis del problema central; P: proceso de internalización; A: auto reflexión y S:Solución del conflicto. Los resultados apuntan hacia la importancia de considerar el cine como una estrategia valiosaen la intervención en grupos.

  16. Influence of the radiographer on the pain felt during mammography

    International Nuclear Information System (INIS)

    Goethem, M. van; Verslegers, I.; Biltjes, I.; De Schepper, A.; Mortelmans, D.; Bruyninckx, E.; Hove, E. Van

    2003-01-01

    Mammography is the only useful examination in screening for breast cancer. Mortality from breast cancer can be reduced if women go regularly for a screening mammography. Moreover, it is still the key examination in diagnosis of breast diseases and in the follow-up of patients treated for breast cancer. Pain with mammography can deter women from going for regular screening or follow-up; therefore, it is important to reduce pain experience or discomfort from mammography. In this study we evaluate the impact of the ''radiographer'' on the pain risk during mammography by analysing questionnaires filled in by women and radiographers. Study results reveal that the opinion of the radiographer, the information and communication during the examination and the number of years of experience are important factors in pain and discomfort experience. The attitude of the radiographer plays an important role in the pain experience. (orig.)

  17. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  18. Peritoneal tuberculosis: radiographic diagnosis

    Directory of Open Access Journals (Sweden)

    Carolina Ospina-Moreno

    2014-12-01

    Full Text Available Peritoneal tuberculosis (TB is an extrapulmonary form of presentation of tuberculosis. HIV infection is a primary risk factor for this condition. Diagnosis requires microbiological or histopathological confirmation in addition to supporting radiological imaging studies. Abdominal ultrasonography and CT are useful to obtain a radiographic diagnosis, with typical findings including diffuse peritoneal thickening, presence of ascites in varying volumes, adenopathies, and caseating nodes. We report 2 cases of patients with ascites and nodular peritoneal thickening on diagnostic images, as well as high CA-125 levels in laboratory tests. In both patients, a diagnosis of peritoneal tuberculosis was reached following a US-guided peritoneal biopsy.

  19. Spirometer-controlled cine magnetic resonance imaging to diagnose tracheobronchomalacia in pediatric patients

    DEFF Research Database (Denmark)

    Ciet, Pierluigi; Wielopolski, Piotr; Manniesing, Rashindra

    2014-01-01

    Tracheobronchomalacia (TBM) is defined as an excessive collapse of the intrathoracic trachea. Bronchoscopy is the gold standard to diagnose TBM, but bronchoscopy has major disadvantages, such as general anaesthesia. Cine-CT is a non-invasive alternative to diagnose TBM, but its use in children...... is restricted by ionizing radiation. Our aim was to evaluate the feasibility of spirometer-controlled cine-MRI as alternative to cine-CT in a retrospective study.12 children (mean 12 years, range 7-17), suspected to have TBM, underwent cine-MRI. Static scans were acquired at end-inspiration and expiration...... covering the thorax using a 3D SPGR sequence. 3D-Dynamic-scans were performed covering only the central airways. TBM was defined as a decrease of the trachea or bronchi diameter greater than 50% at end-expiration in the static and dynamic scans.The success rate of the cine-MRI protocol was 92%. Cine...

  20. Comparisons of images simultaneously documented by digital subtraction coronary arteriography and cine coronary arteriography

    International Nuclear Information System (INIS)

    Kimura, Koji; Takamiya, Makoto; Yamamoto, Kazuo; Ohta, Mitsushige; Naito, Hiroaki

    1988-01-01

    Using an angiography apparatus capable of simultaneously processing digital subtraction angiograms and cine angiograms, the diagnostic capabilities of both methods for the coronary arteries (DSCAG and Cine-CAG) were compared. Twenty stenotic lesions of the coronary arteries of 11 patients were evaluated using both modalities. The severity of stenosis using DSCAG with a 512x512x8 bit matrix was semiautomatically measured on the cathode ray tube (CRT) based on enlarged images on the screen of a Vanguard cine projector which were of the same size as those of or 10 times larger than images of Cine-CAG. The negative and positive hard copies of DSCAG images were also compared with those of Cine-CAG. The correlation coefficients of the severity of stenosis by DSCAG and Cine-CAG were as follows: (1) the same size DSCAG images on CRT to Cine-CAG, 0.95, (2) 10 times enlarged DSCAG images on CRT to Cine-CAG, 0.96, and (3) the same size DSCAG images on negative and positive hard copies to Cine-CAG, 0.97. The semiautomatically measured values of 10 times enlarged DSCAG images on CRT and the manually measured values of the same size negative and positive DSCAG images in hard copy closely correlated with the values measured using Cine-CAG. When the liver was superimposed in the long-axis projection, the diagnostic capabilities of DSCAG and Cine-CAG were compared. The materials included 10 left coronary arteriograms and 11 right coronary arteriograms. Diagnostically, DSCAG was more useful than Cine-CAG in the long-axis projection. (author)

  1. El niño terrible del cine Alemán

    Directory of Open Access Journals (Sweden)

    Hanelore Döbler

    2015-01-01

    Full Text Available Refiere varios temas del cine del director danés Lars Von Trier, llamado el "Niño Terrible del cine" quién manifiesta no pensar en el público al rodar sus películas. Explica lo que es el Dogma 95 del movimiento hiperrealista que busca en aras de la pureza cinematográfica darle un giro de 180 grados a las formas hasta ahora conocidas de hacer cine.

  2. Contrast-enhanced specific absorption rate-efficient 3D cardiac cine with respiratory-triggered radiofrequency gating.

    Science.gov (United States)

    Henningsson, Markus; Chan, Raymond H; Goddu, Beth; Goepfert, Lois A; Razavi, Reza; Botnar, Rene M; Schaeffter, Tobias; Nezafat, Reza

    2013-04-01

    To investigate the use of radiofrequency (RF) gating in conjunction with a paramagnetic contrast agent to reduce the specific absorption rate (SAR) and increase the blood-myocardium contrast in balanced steady-state free precession (bSSFP) 3D cardiac cine. RF gating was implemented by synchronizing the RF-excitation with an external respiratory sensor (bellows), which could additionally be used for respiratory gating. For reference, respiratory-gated 3D cine images were acquired without RF gating. Free-breathing 3D cine images were acquired in eight healthy subjects before and after contrast injection (Gd-BOPTA) and compared to breath-hold 2D cine. RF-gated 3D cine reduced the SAR by nearly 40% without introducing significant artifacts while providing left ventricle (LV) measurements similar to those obtained with 2D cine. The contrast-to-noise ratio (CNR) was significantly higher for 3D cine compared to 2D cine, both before and after contrast injection; however, no statistically significant CNR increase was observed for the postcontrast 3D cine compared to the precontrast acquisitions. Respiratory-triggered RF gating significantly reduces SAR in 3D cine acquisitions, which may enable a more widespread clinical use of 3D cine. Furthermore, CNR of 3D bSSFP cine is higher than of 2D and administration of Gd-BOPTA does not improve the CNR of 3D cine. Copyright © 2012 Wiley Periodicals, Inc.

  3. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  4. Evaluation of cine CT in the investigation of patients with recurrent symptoms following coronary bypass grafting

    International Nuclear Information System (INIS)

    Rees, M.R.; MacMillan, R.M.; Eldredge, W.J.; Maranhao, V.

    1986-01-01

    Between May 1985 and July 1986, cine-CT was performed in 84 consecutive patients to evaluate graft patency and ventricular function. Only three studies (4%) were unsatisfactory. Compared to catheterization, an accuracy of 94% was found for graft patency, with a significant correlation for ejection fraction (r = .93). Close agreement with angiography was demonstrated for cine-CT detection of left ventricular wall motion abnormalities and graft flow. Compared to surgical placement, cine-CT localization of grafts in major coronary territories was 98% accurate. Despite a significant learning curve in study interpretation, cine-CT can be used in place of catheterization in the evaluation of symptomatic postgraft patients

  5. Cine MRI of swallowing in patients with advanced oral or oropharyngeal carcinoma: a feasibility study.

    Science.gov (United States)

    Kreeft, Anne Marijn; Rasch, Coen R N; Muller, Sara H; Pameijer, Frank A; Hallo, Eeke; Balm, Alfons J M

    2012-06-01

    Treatment of oral and oropharyngeal cancer may cause dysphagia. Purpose is to examine whether cine magnetic resonance imaging (MRI) yields additional information compared to standard examination in the evaluation of posttreatment dysphagia and mobility of oral and oropharyngeal structures. Thirty-four cine MRIs were made in 23 patients with advanced oral and oropharyngeal cancer, consisting of an MR image every 800 ms during swallowing which is compared to videofluoroscopy and quality of life questionnaires. A scoring system was applied to assess mobility on cine MR and videofluoroscopy leading to a score ranging from 9 to 17. Cine MRI of the swallowing in a midsagittal plane visualized the tumor (if located in the same plane), important anatomic structures and surgical reconstructions. Posttreatment mobility on cine MRI and videofluoroscopy was significantly diminished compared to pretreatment, mean pretreatment cine MRI score was 10.8 and posttreatment 12.4 (p = 0.017). Impaired mobility on cine MRI was significantly correlated to more swallowing problems (Spearman's correlation coefficient 0.73, p = 0.04), on videofluoroscopy not. Cine MRI is a promising new technique as an adjunct to standard examinations for evaluation of swallowing in patients with oral and oropharyngeal cancer. Cine MRI directly visualizes the dynamics of swallowing and allows evaluation of pre- and posttreatment differences. Abnormal findings are significantly correlated with subjective swallowing complaints of patients.

  6. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE

    International Nuclear Information System (INIS)

    Gao, Hao; Luo, Xiaoyu; Allan, Andrew; McComb, Christie; Berry, Colin

    2014-01-01

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (− 0.18 ± 0.04 versus − 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p < 0.01). In the patient study, the peak strain patterns predicted by cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice. (paper)

  7. Spirometer-controlled cine magnetic resonance imaging used to diagnose tracheobronchomalacia in paediatric patients.

    Science.gov (United States)

    Ciet, Pierluigi; Wielopolski, Piotr; Manniesing, Rashindra; Lever, Sandra; de Bruijne, Marleen; Morana, Giovanni; Muzzio, Pier Carlo; Lequin, Maarten H; Tiddens, Harm A W M

    2014-01-01

    Tracheobronchomalacia (TBM) is defined as an excessive collapse of the intrathoracic trachea. Bronchoscopy is the gold standard for diagnosing TBM; however it has major disadvantages, such as general anaesthesia. Cine computed tomography (CT) is a noninvasive alternative used to diagnose TBM, but its use in children is restricted by ionising radiation. Our aim was to evaluate the feasibility of spirometer-controlled cine magnetic resonance imaging (MRI) as an alternative to cine-CT in a retrospective study. 12 children with a mean age (range) of 12 years (7-17 years), suspected of having TBM, underwent cine-MRI. Static scans were acquired at end-inspiration and expiration covering the thorax using a three-dimensional spoiled gradient echo sequence. Three-dimensional dynamic scans were performed covering only the central airways. TBM was defined as a decrease of the trachea or bronchi diameter >50% at end-expiration in the static and dynamic scans. The success rate of the cine-MRI protocol was 92%. Cine-MRI was compared with bronchoscopy or chest CT in seven subjects. TBM was diagnosed by cine-MRI in seven (58%) out of 12 children and was confirmed by bronchoscopy or CT. In four patients, cine-MRI demonstrated tracheal narrowing that was not present in the static scans. Spirometer controlled cine-MRI is a promising technique to assess TBM in children and has the potential to replace bronchoscopy.

  8. Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling.

    Science.gov (United States)

    Wetzl, Jens; Schmidt, Michaela; Pontana, François; Longère, Benjamin; Lugauer, Felix; Maier, Andreas; Hornegger, Joachim; Forman, Christoph

    2018-02-01

    Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.

  9. Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE.

    Science.gov (United States)

    Gao, Hao; Allan, Andrew; McComb, Christie; Luo, Xiaoyu; Berry, Colin

    2014-07-07

    Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (- 0.18 ± 0.04 versus - 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice.

  10. El individuo singular: el cine de Lars von Trier a la luz de Kierkegaard

    OpenAIRE

    Llavedot Pascual, Laura

    2007-01-01

    Este trabajo trata de ubicar el cine de Lars von Trier dentro de la línea de pensamiento abierta por Kierkegaard. Argumento que el cine de Trier debe comprenderse como un “cine de mostraje” en oposición al “cine de montaje”, y que los procedimientos cinematográficos que Trier emplea son análogos a los procedimientos estilísticos kierkegaardianos en la medida en que para ambos se trata de transmitir una verdad existencial. The aim of this paper is to show Lars von Trier’s films on the persp...

  11. Cine chileno e industria… el desafío que falta

    OpenAIRE

    Fernando Véliz M.

    2006-01-01

    El cine chileno es un campo discursivo de la industria audiovisual aún en proceso de crecimiento. Su historia está cargada de imprecisiones y múltiples inicios que muchas veces quedan truncos; es un cine que se ha comprometido con los problemas sociales, pero que también ha sabido de lejanías y silencios impuestos; es un cine artesanal que aspira a mirar como industrial; es un cine que narra desde el tercer mundo, muchas veces con un 98% de consumo (en sus momentos más...

  12. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)

    International Nuclear Information System (INIS)

    Ghilezan, Michel J.; Jaffray, David A.; Siewerdsen, Jeffrey H.; Herk, Marcel van; Shetty, Anil; Sharpe, Michael B.; Zafar Jafri, Syed; Vicini, Frank A.; Matter, Richard C.; Brabbins, Donald S.; Martinez, Alvaro A.

    2005-01-01

    Purpose: To quantify prostate motion during a radiation therapy treatment using cine-magnetic resonance imaging (cine-MRI) for time frames comparable to that expected in an image-guided radiation therapy treatment session (20-30 min). Materials and Methods: Six patients undergoing radiation therapy for prostate cancer were imaged on 3 days, over the course of therapy (Weeks 1, 3, and 5). Four hundred images were acquired during the 1-h MRI session in 3 sagittal planes through the prostate at 6-s intervals. Eleven anatomic points of interest (POIs) have been used to characterize prostate/bony pelvis/abdominal wall displacement. Motion traces and standard deviation for each of the 11 POIs have been determined. The probability of displacement over time has also been calculated. Results: Patients were divided into 2 groups according to rectal filling status: full vs. empty rectum. The displacement of POIs (standard deviation) ranged from 0.98 to 1.72 mm for the full-rectum group and from 0.68 to 1.04 mm for the empty-rectum group. The low standard deviations in position (2 mm or less) would suggest that these excursions have a low frequency of occurrence. The most sensitive prostate POI to rectal wall motion was the midposterior with a standard deviation of 1.72 mm in the full-rectum group vs. 0.79 mm in the empty-rectum group (p 0.0001). This POI has a 10% probability of moving more than 3 mm in a time frame of ∼1 min if the rectum is full vs. ∼20 min if the rectum is empty. Conclusion: Motion of the prostate and seminal vesicles during a time frame similar to a standard treatment session is reduced compared to that reported in interfraction studies. The most significant predictor for intrafraction prostate motion is the status of rectal filling. A prostate displacement of <3 mm (90%) can be expected for the 20 min after the moment of initial imaging for patients with an empty rectum. This is not the case for patients presenting with full rectum. The determination

  13. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  14. MUJER Y CINE EN AMÉRICA LATINA: PROYECTANDO UNA VISIÓN ALTERNATIVA DE LA NACIÓN

    Directory of Open Access Journals (Sweden)

    Rosa-Linda Fregoso

    2016-01-01

    Full Text Available Al explorar la relación entre cine de mujeres y cines latinoamericanos, este artículo interroga las categorías de cine nacional, cine latinoamericano y cine de mujeres con el fin de superar lógicas geopolíticas, de idiomas, colonialidad, y las lógicas industriales del mercado que han creado esas categorías. Partiendo de interrogantes como qué modelo de análisis feminista del cine es adecuado para articular las perspectivas de mujeres en las nuevas formaciones del cine mundial, propongo la utilidad del discurso de la interseccionalidad para un análisis de cine de mujeres que presente una visión alternativa de la nación.

  15. Anotaciones sobre el cine y la ideología

    Directory of Open Access Journals (Sweden)

    Juan David Cárdenas

    2012-01-01

    Full Text Available El presente artículo apunta a desentrañar una serie de suposiciones naturalizadas con relación a lo que significa hacer cine. Desde sus primeros años cuando se naturalizó una idea de la producción cinematográfica. Este imaginario hizo posible la consolidación del cine como arte y ,a la vez, bloqueó posibles alternativas de cinematografía. En este sentido, este texto desea hacer visible a través de una serie de anotaciones los presupuestos ideológicos que se esconden tras esta naturalización de la producción cinematográfica.

  16. CORRUPCIÓN,LENGUAJE PERIODÍSTICO,CINE,PERIODISMO,ELECCIONES

    Directory of Open Access Journals (Sweden)

    Luis Eladio Proaño

    2015-01-01

    Full Text Available Después de 28 años de la publicación de la Revista ahora se cambia de los temas especulativos a los prácticos para estar al día con las tecnologías. Al tratar el cine se estudia la obra de Almodovar y el cineasta ecuatoriano Cordero, analiza si el cine latinoamericano es escaso y de baja calidad. Con entereza se asume el tema de la corrupción de los periodistas. Se narra lo que hizo Radio La Luna para cubrir la caída de Mahuad y desde Chile se descubren los cambios en el manejo de la imagen en la campaña electoral de Lagos y Lavín. Se cierra la publicación con la ayuda que se da a los periodistas para que eviten errores en el manejo de la lengua castellana.

  17. Anotaciones sobre el fetiche cultural y el cine

    Directory of Open Access Journals (Sweden)

    Juan David Cárdenas

    2014-01-01

    Full Text Available Sobre los fenómenos culturales, sea que se trate de productos de la in - dustria cultural o de actividades de gestión cultural, recae una serie de imaginarios. Dado esto, ellos se comportan como fetiches al modo de la mercancía. El siguiente artículo se propone revisar este carácter de fetiche de los objetos culturales y particularmente del cine, atendiendo en deta - lle algunos de los argumentos que Adorno y Horkheimer exponen sobre la industria cul tural. De este modo, además de precisar algunos aspectos del pensamiento de los teóricos de Frankfurt, nos proponemos revisar la naturaleza profunda del cine como objeto cultural.

  18. New target device and special pillow for cine mode MRI

    International Nuclear Information System (INIS)

    Nishida, Yasuhiro; Murata, Toyotaka.

    1997-01-01

    To carry out cine mode MRI more easily and accurate, we developed a new target device for use with a special pillow. The device consists of a control box, light source and target plate. Red light emission diodes (LED) served on the light source and were connected to the target plate with the light guides each 1 mm in diameter. The light guides were inserted into holes in the target plate. Each target was horizontally and vertically placed at increments of 10 degrees and the maximal angle of 40 degrees. The new target can be correctly gazed at even by elderly patients. By the special pillow, the head of a patients can be easily and quickly fixed in position during examination following removal of air the pillow by vacuum pump. By this target device and pillow, cine mode MRI can be easily carried out on any subject and these should find a great appreciation in ophthalmology. (author)

  19. El cine regional en el Perú

    Directory of Open Access Journals (Sweden)

    Emilio Bustamante

    2014-02-01

    Full Text Available Se expone un panorama del llamado cine regional en el Perú. Se señalan las causas de su aparición; se describe el perfi l del cineasta regional; se explica el sistema de producción, realización, distribución y exhibición de las películas regionales; se analizan los principales géneros abordados por los cineastas regionales, y se mencionan algunas de las películas más importantes de cada género, así como los modos narrativos, la dramaturgia y el lenguaje audiovisual empleado en los filmes. Por último, se reseña el apoyo institucional brindado al cine regional, en especial de parte de Estado a través de los concursos convocados primero por Conacine y después por el Ministerio de Cultura.

  20. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  1. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  2. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  3. Holistic segmentation of the lung in cine MRI.

    Science.gov (United States)

    Kovacs, William; Hsieh, Nathan; Roth, Holger; Nnamdi-Emeratom, Chioma; Bandettini, W Patricia; Arai, Andrew; Mankodi, Ami; Summers, Ronald M; Yao, Jianhua

    2017-10-01

    Duchenne muscular dystrophy (DMD) is a childhood-onset neuromuscular disease that results in the degeneration of muscle, starting in the extremities, before progressing to more vital areas, such as the lungs. Respiratory failure and pneumonia due to respiratory muscle weakness lead to hospitalization and early mortality. However, tracking the disease in this region can be difficult, as current methods are based on breathing tests and are incapable of distinguishing between muscle involvements. Cine MRI scans give insight into respiratory muscle movements, but the images suffer due to low spatial resolution and poor signal-to-noise ratio. Thus, a robust lung segmentation method is required for accurate analysis of the lung and respiratory muscle movement. We deployed a deep learning approach that utilizes sequence-specific prior information to assist the segmentation of lung in cine MRI. More specifically, we adopt a holistically nested network to conduct image-to-image holistic training and prediction. One frame of the cine MRI is used in the training and applied to the remainder of the sequence ([Formula: see text] frames). We applied this method to cine MRIs of the lung in the axial, sagittal, and coronal planes. Characteristic lung motion patterns during the breathing cycle were then derived from the segmentations and used for diagnosis. Our data set consisted of 31 young boys, age [Formula: see text] years, 15 of whom suffered from DMD. The remaining 16 subjects were age-matched healthy volunteers. For validation, slices from inspiratory and expiratory cycles were manually segmented and compared with results obtained from our method. The Dice similarity coefficient for the deep learning-based method was [Formula: see text] for the sagittal view, [Formula: see text] for the axial view, and [Formula: see text] for the coronal view. The holistic neural network approach was compared with an approach using Demon's registration and showed superior performance. These

  4. Clavicle segmentation in chest radiographs

    NARCIS (Netherlands)

    Hogeweg, L.E.; Sanchez, C.I.; Jong, P.A. de; Maduskar, P.; Ginneken, B. van

    2012-01-01

    Automated delineation of anatomical structures in chest radiographs is difficult due to superimposition of multiple structures. In this work an automated technique to segment the clavicles in posterior-anterior chest radiographs is presented in which three methods are combined. Pixel classification

  5. Two-dimensional sonographic cine imaging improves confidence in the initial evaluation of the fetal heart.

    Science.gov (United States)

    Poole, Patricia Sims; Chung, Romy; Lacoursiere, Yvette; Palmieri, Carolina Rossi; Hull, Andrew; Engelkemier, Dawn; Rochelle, Michele; Trivedi, Neha; Pretorius, Dolores H

    2013-06-01

    Initial screening sonography of the fetal heart with static images is often inadequate, resulting in repeated imaging or failure to detect abnormalities. We hypothesized that the addition of short cine clips would reduce the need for repeated imaging. Two-dimensional (2D) static sonograms and short 2D cine clips of the 4-chamber view and left and right ventricular outflow tracts were obtained from 342 patients with gestational ages of greater than 16 weeks. A diagnostic radiologist and a perinatologist retrospectively reviewed the static and cine images independently and graded them as normal, abnormal, or suboptimal. A statistically significant increase in the number of structures called normal was seen when 2D cine clips were added to static imaging for both observers (P cine images versus 61.9% with static images alone, whereas the perinatologist recorded 68.1% as normal versus 58.8%, respectively. The radiologist called 77.8% of structures normal with cine images only versus 61.9% with static images only (P cine images alone (38.9%) versus static images alone (58.8%). The use of cine loops alone resulted in no significant increase in the ability to clear the heart as normal. The maternal body mass index was inversely associated with the ability to clear structures when 2D cine images were added to static images (P cine clips to standard 2D static imaging of the fetal heart significantly improves the number of structures cleared as normal. Two-dimensional cine clips are easily obtained, add little time to a study, and require minimal archival space.

  6. Evaluation of aortic distensibility using cine MR imaging

    International Nuclear Information System (INIS)

    Takahashi, Masashi; Murata, Kiyoshi; Mori, Masayuki

    1992-01-01

    Regional aortic distensibility was measured noninvasively using cine MR imaging to determine whether it correlates with aging or risk of coronary artery disease (CAD). Twenty-two patients with CAD confirmed by angiography and 33 without CAD underwent cine MR imaging. Thirty-two sequential images were obtained in one cardiac cycle. The cross sectional area of the descending thoracic aorta was measured on both diastolic (A) and systolic (A') images. Aortic distensibility (A.D.) was calculated from the following equation: A.D.=(A'-A)/A/ΔP.(ΔP represents pulse pressure). Results of a simple regression analysis showed that decreased regional aortic distensibility was significantly correlated with the age of the patients (r=-0.762, p<0.005). In addition, the parameter was lower in patients with CAD than those without CAD (p<0.05). In conclusion, regional aortic distensibility derived from cine MR imaging is a useful parameter to evaluate not only aging but also pathological atherosclerosis of the aorta. In addition, this parameter might have some potential to evaluate the prediction of CAD in patients with normal serum cholesterol. (author)

  7. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  8. Río de Janeiro bajo la mirada del cine extranjero

    Directory of Open Access Journals (Sweden)

    Antonio Carlos (Tunico Amancio

    2009-01-01

    Full Text Available La imagen de Brasil en el cine extranjero de ficción se constituyó a través de la representación de la ciudad de Río de Janeiro, concebida como la capital cultural del país. Desde una visión panorámica, el artículo revela aspectos históricos y dramáticos de esa construcción, analizando decenas de películas que tienen a la "ciudad maravillosa" y a sus habitantes como objeto. El trabajo describe las transformaciones que se dieron en el imaginario social, gestado desde una visión edénica de la antigua capital de Brasil y que experimentó diversos cambios con el correr de las décadas.

  9. Periodontal probing versus radiographs for the diagnosis of furcation involvement.

    Science.gov (United States)

    Graetz, Christian; Plaumann, Anna; Wiebe, Jan-Frederik; Springer, Claudia; Sälzer, Sonja; Dörfer, Christof E

    2014-10-01

    Decisions in periodontal therapy for multirooted teeth are essentially based on accurate diagnosis of the furcation involvement (FI). Furcation probing (FP) is still the basic diagnostic measure, although the assessment may be difficult. The aim of this study is to evaluate the validity of FP and radiographic assessment of FI compared with visual assessment during open flap surgery (OFS). In this retrospective clinical cohort study, 215 participants with periodontal disease and at least one molar treated with OFS were enrolled, and a total of 834 molars were assigned for FI by FP and in radiographs analyzed by an experienced (EE) and less experienced examiner (LE). For the investigation, 143 panoramic radiographs (OPGs) and 77 intra-oral radiographs (I-Os) were evaluated. The Class of FI by FP was confirmed in 56%, whereas 15% were overestimated and 29% underestimated. FI Class 0 and I had been detected with high probability (74% and 54%, respectively). Of all FI Class III, 57% were detected correctly by radiographs and 32% by FP. FP and OFS revealed a weighted κ-coefficient (κw) = 0.588; radiographs and OFS had κw = 0.542 (OPG κw = 0.555 and I-O κw = 0.521). The interrater reliability for radiographs was dependent on the experience of the examiner (EE κw = 0.618; LE κw = 0.426). Experience in analyzing conventional radiographs increases the potential of correct diagnosis of advanced FI. The reliability of FP compared with radiographic assessment depends on the anatomy and location of the tooth. Both diagnostic tools should be used in cases of suspected FI.

  10. Cine chileno e industria… el desafío que falta

    Directory of Open Access Journals (Sweden)

    Fernando Véliz M.

    2006-01-01

    Full Text Available El cine chileno es un campo discursivo de la industria audiovisual aún en proceso de crecimiento. Su historia está cargada de imprecisiones y múltiples inicios que muchas veces quedan truncos; es un cine que se ha comprometido con los problemas sociales, pero que también ha sabido de lejanías y silencios impuestos; es un cine artesanal que aspira a mirar como industrial; es un cine que narra desde el tercer mundo, muchas veces con un 98% de consumo (en sus momentos más fuertes de producción norteamericana; es decir, es un cine que se ha formado en la autogestión absoluta de su capital simbólico. Es un cine que, por medio de libros y películas de culto, está generando una nueva camada de directores, los cuales buscan comprender su rol en esta industria que hoy, ya con el pasar del tiempo, tiene audiencias cautivas. Es un cine que a ratos camina junto al Estado y, en otras ocasiones, es la soledad su compañera de ruta. Es un cine fundado en la creatividad, búsqueda y superación de su oficio, y que poco a poco, comprende que el valor agregado está en sus historias locales.

  11. Usefulness of true FISP cine MR imaging in patients with poor cardiac function

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Toshiharu; Yamada, Naoaki; Motooka, Makoto; Enomoto, Naoyuki; Maeshima, Isamu; Matsuda, Kazuhide; Urayama, Shinichi; Ikeo, Miki [National Cardiovascular Center, Suita, Osaka (Japan)

    2002-01-01

    This study was done to assess the value of True FISP cine in patients with poor cardiac function. True FISP cine and FLASH cine imaging were performed on a 1.5 T machine. Both short axis and horizontal long axis imaging sections were used. The imaging sections used a Matrix (120 x 128), FOV (24 x 32 cm), and had a slice thickness of 8 mm. The imaging time for True FISP cine was 8 heart beats and 17 heart beats for FLASH cine. The contrast-to-noise ratio between the blood and myocardium (CNR) was measured at enddiastole and endsystole. The subjects in the study were 10 healty volunteers (average age 26.5{+-}3.2 years) and 12 patients with hypofunction (average age 53.9{+-}13.2 years). In the volunteers, the CNR of the short axis imaging was similar in both True FISP (24.6{+-}3.7) and FLASH (23.4{+-}5.9). In the patients with poor cardiac function however, the CNR of True FISP was larger than FLASH in both the short and long axis. In the short axis (22.7{+-}6.1 vs. 17.9{+-}5.3, P<0.01) and in the long axis (17.4{+-}4.3 vs. 9.3{+-}4.0, P<0.01). We conclude that True FISP cine has a higher contrast in a shorter imaging time than FLASH cine. True FISP cine is especially useful in patients with poor cardiac function. (author)

  12. Cine computed tomography for diagnosis of superior vena cava obstruction following the mustard operation

    International Nuclear Information System (INIS)

    Matherne, G.P.; Atkins, D.L.; Frey, E.E.; Smith, W.L.

    1987-01-01

    Superior vena caval obstruction is a well described complication following Mustard's repair for transposition of the great arteries. We report a case of a 6-year-old child with superior vena cava obstruction correctly diagnosed by Cine-CT. The advantages of imaging with Cine-CT for this complication are discussed. (orig.)

  13. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  14. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function

    NARCIS (Netherlands)

    Coolen, Bram F.; Abdurrachim, Desiree; Motaal, Abdallah G.; Nicolay, Klaas; Prompers, Jeanine J.; Strijkers, Gustav J.

    2013-01-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered

  15. Simultaneous static and cine nonenhanced MR angiography using radial sampling and highly constrained back projection reconstruction.

    Science.gov (United States)

    Koktzoglou, Ioannis; Mistretta, Charles A; Giri, Shivraman; Dunkle, Eugene E; Amin, Parag; Edelman, Robert R

    2014-10-01

    To describe a pulse sequence for simultaneous static and cine nonenhanced magnetic resonance angiography (NEMRA) of the peripheral arteries. The peripheral arteries of 10 volunteers and 6 patients with peripheral arterial disease (PAD) were imaged with the proposed cine NEMRA sequence on a 1.5 Tesla (T) system. The impact of multi-shot imaging and highly constrained back projection (HYPR) reconstruction was examined. The propagation rate of signal along the length of the arterial tree in the cine nonenhanced MR angiograms was quantified. The cine NEMRA sequence simultaneously provided a static MR angiogram showing vascular anatomy as well as a cine display of arterial pulse wave propagation along the entire length of the peripheral arteries. Multi-shot cine NEMRA improved temporal resolution and reduced image artifacts. HYPR reconstruction improved image quality when temporal reconstruction footprints shorter than 100 ms were used (P cine NEMRA was slower in patients with PAD than in volunteers. Simultaneous static and cine NEMRA of the peripheral arteries is feasible. Multi-shot acquisition and HYPR reconstruction can be used to improve arterial conspicuity and temporal resolution. Copyright © 2013 Wiley Periodicals, Inc.

  16. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  17. Cine-CT: A new technique in X-ray computed tomography

    International Nuclear Information System (INIS)

    Jaschke, W.; Georgi, M.; Lipton, M.J.; Gould, R.G.

    1988-01-01

    The 'Cine-CT' belongs to a new generation of CT devices permitting not only diagnostics on a morphological basis but also function studies. By means of Cine-CT's electron beam technique, image frequencies of up to 17 images per second and exposure times of 50 msec are possible. (orig.) [de

  18. Uso y errores del uso de las armas de fuego en el cine

    OpenAIRE

    Alonso Martínez, Alberto

    2015-01-01

    Se realiza un estudio, según géneros cinematográficos (histórico, wéstern, negro, bélico, acción y ciencia ficción) del uso de las armas de fuego en el cine, centrándose en el cine de ciencia ficción.

  19. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  20. The diagnostic value of cine-MR imaging in diseases of great vessels

    International Nuclear Information System (INIS)

    Sasaki, Shigeyuki; Yoshida, Hideaki; Matsui, Yoshiro; Sakuma, Makoto; Yasuda, Keihide; Tanabe, Tatsuzo; Chouji, H.

    1990-01-01

    The diagnostic value of cine magnetic resonance imaging (cine-MRI) was evaluated in 10 patients with diseases of great vessels. The parameters necessary to decide the appropriate treatment, such as presence and extension of intimal flap, DeBakey type classification, identification of the entry, differentiation between true and false lumen, and between thrombosis and slow flow were demonstrated in all patients with dissecting aortic aneurysm. However, abdominal aortic branches could not be demonstrated enough by cine-MRI, therefore conventional AOG was necessary to choose the operative procedure in these cases. In patients with thoracic aortic aneurysm (TAA), cine-MRI was valuable in demonstrating both blood flow and thrombus in the lumen of aneurysm, and AOG was thought to be unnecessary in most cases. Cine-MRI is a promising new technique for the evaluation of diseases of great vessels. (author)

  1. Cine-CT diagnosis of coronary artery aneurysms in patients with Kawasaki

    International Nuclear Information System (INIS)

    Frey, E.E.; Matherne, G.P.; Mahoney, L.T.; Sato, Y.; Stanford, W.; Smith, W.L.

    1987-01-01

    Coronary artery aneurysms (CAA) are the most serious late sequelae of Kawasaki disease, and periodic screening examinations are necessary. Two-dimensional (2D) echocardiography represents the standard screening method; however, visualization of the distal coronary arteries is often limited. This report documents the complimentary role of cine-CT with 2D echocardiography in the evaluation of CAA induced by Kawasaki disease. Six pediatric patients with coronary aneurysms were evaluated with both 2D echocardiography and cine-CT. Cine-CT detected ten of 11 lesions. The one misdiagnosed CAA was one of the two contiguous aneurysms. Owing to intersection thickness, these two discrete aneurysms were interpreted as a solitary aneurysm. Cine-CT detected one CAA not initially visualized on echocardiography. Cine-CT is effective and complementary to 2D echocardigraphy as a noninvasive method for the evaluation of coronary artery aneurysms occurring as sequelae of Kawasaki disease

  2. Meso-scale modelling of directional solidification and comparison with in situ X-ray radiographic observations made during the MASER-12 XRMON microgravity experiment

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, A.G., E-mail: andrew.murphy.1@ucdconnect.ie [School of Mechanical and Materials Engineering, University College Dublin (Ireland); Reinhart, G.; Nguyen-Thi, H.; Salloum Abou Jaoude, G. [Aix-Marseille Univ., Campus Saint-Jérome Case 142, 13397 Marseille Cedex 20 (France); CNRS, IM2NP UMR 7334, Campus Saint-Jérome Case 142, 13397 Marseille Cedex 20 (France); Browne, D.J. [School of Mechanical and Materials Engineering, University College Dublin (Ireland)

    2013-10-05

    Highlights: •Mesoscopic simulation of in situ X-ray monitored solidification in microgravity. •Extent and magnitude of undercooled zone ahead of dendrite front predicted. •Dynamic thermal response of new XRMON-GF Bridgman furnace analysed. -- Abstract: Computational modelling of advanced solidification processes has made considerable advances over the last half century, with ever increasing levels of modelling complexity. There is, therefore, an increasing need for state of the art experimental investigation to provide suitable validation for these model predictions. In situ X-ray radiography has become a powerful tool for solidification experimentation. Using either synchrotron or microfocus X-ray sources, thin samples, encased in X-ray transparent crucibles, can be directionally or isothermally solidified, allowing for direct real time observation of dynamic solidification phenomena. This paper presents the results of a meso-scale Front Tracking simulation of a directional solidification experiment, performed using an Al–20 wt.% Cu alloy, carried out under microgravity conditions on board the MASER 12 sounding rocket. The sample was mounted in a Bridgman type gradient furnace and solidified using a prescribed cooling regime with a constant gradient, thus promoting directional solidification in the field of view. The actual thermal gradient in the sample was found to be lower than the nominal thermal gradient, as set/recorded by thermocouples embedded in the heater elements. The adjusted thermal data were supplied as inputs to the Front Tracking model and good agreement was then observed between the model predictions and the in situ observations. The extent and amplitude of the undercooled zone ahead of the columnar front was predicted based on analytical growth kinetics laws and the results were also compared to analytical models of columnar-to-equiaxed transition (CET) prediction.

  3. Chest radiographic findings of leptospirosis

    International Nuclear Information System (INIS)

    Kim, Mee Hyun; Jung, Hee Tae; Lee, Young Joong; Yoon, Jong Sup

    1986-01-01

    1. A study on chest radiographic findings of 54 cases with pneumonia like symptoms was performed. Of 54 cases, 8 cases were confirmed to be leptospirosis and 7 cases were leptospirosis combined with Korean hemorrhagic fever. 2. Of 8 cases of leptospirosis, 4 cases showed abnormal chest radiographic findings: acinar nodular type 2, massive confluent consolidation type 2. Of 7 cases of leptospirosis combined with Korean hemorrhagic fever: acinar nodular type 3, massive confluent consolidation type 1, and increased interstitial markings type 1 respectively. 3. It was considered to be difficult to diagnose the leptospirosis on chest radiographic findings alone, especially the case combined with Korean hemorrhagic fever.

  4. Free-breathing steady-state free precession cine cardiac magnetic resonance with respiratory navigator gating.

    Science.gov (United States)

    Moghari, Mehdi H; Komarlu, Rukmini; Annese, David; Geva, Tal; Powell, Andrew J

    2015-04-01

    To develop and validate a respiratory motion compensation method for free-breathing cardiac cine imaging. A free-breathing navigator-gated cine steady-state free precession acquisition (Cine-Nav) was developed which preserves the equilibrium state of the net magnetization vector, maintains the high spatial and temporal resolutions of standard breath-hold (BH) acquisition, and images entire cardiac cycle. Cine image data is accepted only from cardiac cycles occurring entirely during end-expiration. Prospective validation was performed in 10 patients by obtaining in each three complete ventricular image stacks with different respiratory motion compensation approaches: (1) BH, (2) free-breathing with 3 signal averages (3AVG), and (3) free-breathing with Cine-Nav. The subjective image quality score (1 = worst, 4 = best) for Cine-Nav (3.8 ± 0.4) was significantly better than for 3AVG (2.2 ± 0.5, P = 0.002), and similar to BH (4.0 ± 0.0, P = 0.13). The blood-to-myocardium contrast ratio for Cine-Nav (6.3 ± 1.5) was similar to BH (5.9 ± 1.6, P = 0.52) and to 3AVG (5.6 ± 2.5, P = 0.43). There were no significant differences between Cine-Nav and BH for the ventricular volumes and mass. In contrast, there were significant differences between 3AVG and BH in all of these measurements but right ventricular mass. Free-breathing cine imaging with Cine-Nav yielded comparable image quality and ventricular measurements to BH, and was superior to 3AVG. © 2014 Wiley Periodicals, Inc.

  5. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  6. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  7. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  8. Analysis of speech and tongue motion in normal and post-glossectomy speaker using cine MRI.

    Science.gov (United States)

    Ha, Jinhee; Sung, Iel-Yong; Son, Jang-Ho; Stone, Maureen; Ord, Robert; Cho, Yeong-Cheol

    2016-01-01

    Since the tongue is the oral structure responsible for mastication, pronunciation, and swallowing functions, patients who undergo glossectomy can be affected in various aspects of these functions. The vowel /i/ uses the tongue shape, whereas /u/ uses tongue and lip shapes. The purpose of this study is to investigate the morphological changes of the tongue and the adaptation of pronunciation using cine MRI for speech of patients who undergo glossectomy. Twenty-three controls (11 males and 12 females) and 13 patients (eight males and five females) volunteered to participate in the experiment. The patients underwent glossectomy surgery for T1 or T2 lateral lingual tumors. The speech tasks "a souk" and "a geese" were spoken by all subjects providing data for the vowels /u/ and /i/. Cine MRI and speech acoustics were recorded and measured to compare the changes in the tongue with vowel acoustics after surgery. 2D measurements were made of the interlip distance, tongue-palate distance, tongue position (anterior-posterior and superior-inferior), tongue height on the left and right sides, and pharynx size. Vowel formants Fl, F2, and F3 were measured. The patients had significantly lower F2/Fl ratios (F=5.911, p=0.018), and lower F3/F1 ratios that approached significance. This was seen primarily in the /u/ data. Patients had flatter tongue shapes than controls with a greater effect seen in /u/ than /i/. The patients showed complex adaptation motion in order to preserve the acoustic integrity of the vowels, and the tongue modified cavity size relationships to maintain the value of the formant frequencies.

  9. Scanning radiographic apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Albert, R.D.

    1980-04-01

    Visual display of dental, medical or other radiographic images is realized with an x-ray tube in which an electron beam is scanned through an x-y raster pattern on a broad anode plate, the scanning being synchronized with the x-y sweep signals of a cathode ray tube display and the intensity signal for the display being derived from a small x-ray detector which receives x-rays that have passed through the subject to be imaged. Positioning and support of the detector are provided for by disposing the detector in a probe which may be attached to the x-ray tube at any of a plurality of different locations and by providing a plurality of such probes of different configuration in order to change focal length, to accommodate to different detector placements relative to the subject, to enhance patient comfort and to enable production of both periapical images and wider angle pantomographic images. High image definition with reduced radiation dosage is provided for by a lead glass collimator situated between the x-ray tube and subject and having a large number of spaced-apart minute radiation transmissive passages convergent on the position of the detector. Releasable mounting means enable changes of collimator in conjunction with changes of the probe to change focal length. A control circuit modifies the x-y sweep signals applied to the x-ray tube and modulates electron beam energy and current in order to correct for image distortions and other undesirable effects which can otherwise be present in a scanning x-ray system.

  10. Do general radiographic examinations resemble a person-centred environment?

    International Nuclear Information System (INIS)

    Hayre, C.M.; Blackman, S.; Eyden, A.

    2016-01-01

    Aim and objective: It is argued whether general radiographic examinations adhere to a person-centred approach within the direct digital radiography (DDR) environment. General radiographic examinations continue to increase and constitute approximately 90% of all examinations undertaken in the clinical environment. This study explored the potential impact patients experience whilst undergoing general imaging examinations. Method: An ethnographic methodology provided insight of two general radiography environments in the United Kingdom (UK) using participant observation and semi-structured interviews. Findings: The findings highlighted an ‘in and out’ culture whereby patients are ‘hurried’ and ‘rushed’ out of X-ray rooms in response to increasing time pressures experienced by diagnostic radiographers. In addition, this study challenged that patients may begin to rank ‘speed’ and ‘waiting times’ above other elements of radiographic care thus presenting new challenges for radiographers within the clinical environment. Conclusion: It is asserted that radiographers should remain holistic healthcare professionals and not begin to resemble operators on the production line. Further, it challenges whether patients are beginning to rank aspects of radiographic care within contemporary practices. Advances in knowledge: Few studies have explored the radiographer–patient relationship within the DDR environment, yet this study provides insight of person-centred practices within contemporary practices. - Highlights: • Challenges whether the use of DDR conforms to a person-centred approach. • Challenges whether radiographers are ‘treating patients as persons’ using DDR. • Patients may begin to rank ‘speed’ and ‘waiting times’ above other aspects of radiographic care.

  11. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  12. When disaster strikes; the role of the forensic radiographer

    International Nuclear Information System (INIS)

    Walsh, Mary; Reeves, Pauline; Scott, Susan

    2004-01-01

    Forensic radiography is a vital tool utilised in the many facets of Forensic Medicine. This paper investigates the role of the forensic radiographer in a mass disaster situation; it also explores the psychological impact of this type of work on radiographers. A literature review indicated that limited work had been documented on the role of the radiographer in mass disasters. This ultimately creates doubt about whether or not the radiographer is acknowledged for the vital role he/she plays and if proper provisions were in place to assess any emotional damage in the aftermath of an emotionally and physically straining situation. A qualitative method of research was used (semi-structured interviews) in order to elicit radiographers' feelings and perceptions. This method is best suited to this research topic because it is a delicate subject. Four interviews were carried out and the responses are presented in themes including emergency versus mass grave experiences (including issues of time and preparation). Other themes include the role of the radiographer and interaction with other members of the team, as well as a discussion of the aftermath of their experiences, including the feelings of pride experienced

  13. Cine MRI of the thorax in patients with pectus excavatum

    International Nuclear Information System (INIS)

    Herrmann, K.A.; Zech, C.J.; Schoenberg, S.O.; Reiser, M.F.; Strauss, T.; Hatz, R.

    2006-01-01

    Morphologic and dynamic assessment of respiratory chest kinetics was performed in patients with pectus excavatum deformity (PE) using dynamic MRI: cine MRI. Seven consecutive patients with PE (aged 20.3 years±4.0) and ten healthy volunteers of comparable age underwent real-time cine MRI of the chest during breathing on a 1.5 T MR scanner (Magnetom Sonata, Siemens Medical Systems, Erlangen, Germany) using a standard phased array body coil and a half-Fourier single-shot turbo spin echo sequence (HASTE) for dynamic imaging. During deep inspiration and expiration, single-shot sequences were performed in one slice level over 20 s at a frequency of 1 image/s covering the entire thoracic cage in three orientations. Morphology and chest kinetics in patients with PE were analyzed and compared with normal values, and typical patterns of chest kinetics were noted. Three different types of chest morphology in PE were identified: (1) the generally flattened thoracic cage, (2) the ''tilted'' sternum, and (3) the focally deepened sternum. Three patterns of motion correspond to these morphological types: (1) elevation of the sternum and the anterior thoracic wall, (2) angulated elevation of the parasternal rib cage with persistent deepening of the sternum resembling a ''wing beat'' movement, and (3) increased diaphragmatic movements with limited chest wall dynamics. Cine MRI is an adequate radiation-free diagnostic modality for the dynamic imaging of both chest morphology and chest wall kinetics in patients with PE. The pectus severity index can easily be determined and three typical movement patterns of chest wall kinetics identified. (orig.) [de

  14. Opportunistic esophagitis in AIDS: radiographic diagnosis.

    Science.gov (United States)

    Levine, M S; Woldenberg, R; Herlinger, H; Laufer, I

    1987-12-01

    Thirty-five of 90 patients with acquired immunodeficiency syndrome (AIDS) seen between 1983 and 1986 underwent esophagography (double contrast in all but two) to rule out opportunistic esophagitis; 20 of the 35 were found to have fungal or viral esophagitis. A radiographic diagnosis of Candida esophagitis was made in 17 patients because of varying degrees of plaque formation. Seven of those patients had a grossly irregular or "shaggy" esophagus; in four, the diagnosis of AIDS was initially suspected from this finding. In the remaining three patients, a radiographic diagnosis of viral esophagitis (herpes simplex in two and cytomegalovirus in one) was made because of discrete ulcers on a normal background mucosa. Eighteen patients had endoscopic, clinical, or autopsy findings that corroborated the radiographic diagnosis; follow-up data were not available for two patients with Candida esophagitis. This experience suggests that fungal and viral esophagitis can often be differentiated with double-contrast esophagography, enabling appropriate antifungal or antiviral therapy to be instituted without endoscopic intervention.

  15. La representación del porrajmos en el cine

    OpenAIRE

    Dawidiuk, Carlos Luciano

    2012-01-01

    Esa asimetría, que ha relegado al Porrajmos al olvido, tiene su correlato en el cine. Es decir, que si bien podemos notar que existe claramente en el imaginario colectivo una memoria del Holocausto/Shoah tejida, no sólo por los testimonios de los supervivientes, sino también por las imágenes creadas por los medios de comunicación y el arte de las últimas décadas, con respecto al genocidio gitano es evidente una amnesia casi total. Y, en este sentido, no deja de ser significativo que las escas...

  16. El sonido en el cine de Apichatpong Weerasethakul

    OpenAIRE

    Expósito-Barea, Milagros

    2008-01-01

    El sonido es un aspecto poco estudiado en los análisis cinematográficos. Solamente la música ha conseguido alcanzar un cierto estatus dentro de los mismos. Con este artículo se pretende poner en práctica las diferentes connotaciones que puede tener el sonido a partir de la obra del director de cine tailandés Apichatpong Weerasethakul, gran impulsor de proyectos audio-visuales en el sentido más amplio y heterogéneo del término.

  17. A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against

  18. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  19. El cine ante las transformaciones y los flujos comunicativos globales

    Directory of Open Access Journals (Sweden)

    Francisco Javier Ruiz del Olmo

    2012-06-01

    Full Text Available La convocatoria del presente número monográfico sobre los cambios producidos en el dispositivo cinematográfico de las últimas décadas, deliberadamente amplia y multifacética, no excluía sin embargo una cierta focalización hacia el estudio que la diseminación de nuevas prácticas culturales, consecuencia de la digitalización de la imagen de las relaciones entre el cine y la red y los flujos comunicativos globales.

  20. A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Wendy [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Ren, Lei, E-mail: lei.ren@duke.edu [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Cai, Jing [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Zhang, You [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Chang, Zheng; Yin, Fang-Fang [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2016-06-01

    Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against

  1. La música en el cine de Ingmar Bergman

    OpenAIRE

    Azzam Gómez, Marcos

    2011-01-01

    [ES] Esta Tesis Doctoral investiga la presencia y funcionalidad de la música en el cine de Ingmar Bergman. Tal funcionalidad ha sido analizada desde diversos niveles: dramático, estructural, narrativo, estético, simbólico, metatextual, emocional, etc. Para este propósito, he tomado ejemplos de la música contenida en cuarenta de las películas del director, desde la Música Clásica preexistente a la banda sonora original. Considerando la Música Clásica preexistente, destaca especialmente el trab...

  2. Cine y Filosofía. Sus rostros

    Directory of Open Access Journals (Sweden)

    Jose Fernando Saldarriaga

    2014-12-01

    Full Text Available El presente estudio es un esquema para construir una cartografía del rostro en la obra cinematográfica del director sueco Ingmar Bergman. Películas como: Crisis (Kris, 1946, Un verano con Mónica (Som- maren med Monika, 1953, El silencio (Tystnaden, 1963 y Fresas Salvajes (Smultronstället, 1957, permiten aplicar las nociones filosóficas estudiadas por Gilles Delueze: rizoma, plano inmanente, plano afección, rostriedad en el marco histórico y estético. Cine y filosofía son los medios de estos pensadores.

  3. Experiences of being a therapy radiographer

    Directory of Open Access Journals (Sweden)

    Heather Lawrence

    2011-11-01

    Opsomming Die hoofdoel van hierdie navorsing is om te verken en beskryf hoe radioterapeute hulle beroep beleef. ‘n Kwalitatiewe, verkennende, beskrywende en kontekstuele navorsingsontwerp is gebruik. Die doelgerigte steekproef het bestaan uit 14 radioterapeute werksaam by ‘n akademiese hospitaal in Gauteng, Suid Afrika. Data is met behulp van fokusgroep onderhoude ingesamel totdat dataversadiging bereik is. ‘n ‘Appreciative inquiry’ onderhoudstegniek is gebruik met die stel van vrae, en data analise is met behulp van oop kodering gedoen om temas te identifiseer. Die temas wat geidentifiseer was is lewensgewende magte wat persoonlike en professionele betrokkenheid bevorder wat ‘n singewing tot gevolg het; professionele stagnering; en fasilitering van verandering deur die gebruikmaking van positiewe energie en toewyding vir verandering.

  4. Cine magnetic resonance imaging for evaluation of cardiac structure and flow dynamics in congenital heart disease

    International Nuclear Information System (INIS)

    Akagi, Teiji; Kiyomatsu, Yumi; Ohara, Nobutoshi; Takagi, Junichi; Sato, Noboru; Kato, Hirohisa; Eto, Takaharu.

    1989-01-01

    Cine magnetic resonance imaging (Cine MRI) was performed in 20 patients aged 19 days to 13 years (mean 4.0 years), who had congenital heart disease confirmed at echocardiography or angiography. Prior to cine MRI, gated MRI was performed to evaluate for cardiac structure. Cine MRI was demonstrated by fast low fip angle shot imaging technique with a 30deg flip angle, 15 msec echo time, 30-40 msec pulse repetition time, and 128 x 128 acquisition matrix. Abnormalities of cardiac structure were extremely well defined in all patients by gated MRI. Intracardiac or intravascular blood flow were visualized in 17 (85%) of 20 patients by cine MRI. Left to right shunt flow through ventricular septal defect, atrial septal defect, and endocardial cushion defect were visualized with low signal intensity area. Low intensity jets flow through the site of re-coarctation of the aorta were also visualized. However, the good recording of cine MRI was not obtained because of artifacts in 3 of 20 patients (15%) who had severe congestive heart failure or respiratory arrhythmia. Gated MRI provides excellent visualization of fine structure, and cine MRI can provide high spatial resolution imaging of flow dynamic in a variety of congenital heart disease, noninvasively. (author)

  5. Megavoltage conebeam CT cine as final verification of treatment plan in lung stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Kudithipudi, Vijay; Gayou, Olivier; Colonias, Athanasios

    2016-01-01

    To analyse the clinical impact of megavoltage conebeam computed tomography (MV-CBCT) cine on internal target volume (ITV) coverage in lung stereotactic body radiotherapy (SBRT). One hundred and six patients received lung SBRT. All underwent 4D computed tomography simulation followed by treatment via image guided 3D conformal or intensity modulated radiation. Prior to SBRT, all patients underwent MV-CBCT cine, in which raw projections are displayed as beam's-eye-view fluoroscopic series with the planning target volume (PTV) projected onto each image, enabling verification of tumour motion relative to the PTV and assessment of adequacy of treatment margin. Megavoltage conebeam computed tomography cine was completed 1–2 days prior to SBRT. Four patients (3.8%) had insufficient ITV coverage inferiorly at cine review. All four plans were changed by adding 5 mm on the PTV margin inferiorly. The mean change in PTV volumes was 3.9 cubic centimetres (cc) (range 1.85–6.32 cc). Repeat cine was performed after plan modification to ensure adequate PTV coverage in the modified plans. PTV margin was adequate in the majority of patients with this technique. MV-CBCT cine did show insufficient coverage in a small subset of patients. Insufficient PTV margins may be a function of 4D CT simulation inadequacies or deficiencies in visualizing the ITV inferior border in the full-inhale phase. MV-CBCT cine is a valuable tool for final verification of PTV margins.

  6. Cine dyscontractility index: A novel marker of mechanical dyssynchrony that predicts response to cardiac resynchronization therapy.

    Science.gov (United States)

    Werys, Konrad; Petryka-Mazurkiewicz, Joanna; Błaszczyk, Łukasz; Miśko, Jolanta; Śpiewak, Mateusz; Małek, Łukasz A; Mazurkiewicz, Łukasz; Miłosz-Wieczorek, Barbara; Marczak, Magdalena; Kubik, Agata; Dąbrowska, Agnieszka; Piątkowska-Janko, Ewa; Sawionek, Błażej; Wijesurendra, Rohan; Piechnik, Stefan K; Bogorodzki, Piotr

    2016-12-01

    To investigate whether magnetic resonance imaging (MRI) cine-derived dyssynchrony indices provide additional information compared to conventional tagged MRI (tMRI) acquisitions in heart failure patients undergoing cardiac resynchronization therapy (CRT). Patients scheduled for CRT (n = 52) underwent preprocedure MRI including cine and tMRI acquisitions. Segmental strain curves were calculated for both cine and tMRI to produce a range of standard indices for direct comparison between modalities. We also proposed and evaluated a novel index of "dyscontractility," which detects the presence of focal areas with paradoxically positive circumferential strain. Across conventional strain indices, there was only moderate-to-poor (R = 0.3-0.6) correlation between modalities; eight cine-derived indices showed statistically significant (P cine images (cine dyscontractility index, "CDI") was the single best predictor of clinical response to CRT (area under the curve AUC = 0.81, P Cine-derived strain indices offer potentially new information compared to tMRI. Specifically, the novel CDI is most strongly linked to response to cardiac resynchronization therapy in a contemporary patient cohort. It utilizes readily available MRI data, is relatively straightforward to process, and compares favorably with any conventional tagging index. J. Magn. Reson. Imaging 2016;44:1483-1492. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty.

    Science.gov (United States)

    Chen, Guoqiang; Zheng, Jiaping; Xiao, Qing; Liu, Yunsheng

    2013-06-01

    The aim of this study was to evaluate the application of phase-contrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty (EA) for patients with obstructive hydrocephalus. The clinical diagnosis of hydrocephalus caused by aqueduct obstruction in 23 patients was confirmed by phase-contrast cine MRI examination. The patients were treated with EA and MRI was repeated during the follow-up. The cerebrospinal fluid (CSF) flow velocity in the aqueduct was measured to determine whether the aqueduct was obstructed. The results of phase-contrast cine MRI examinations indicated that there was no CSF flow in the aqueduct for all patients prior to surgery. Aqueductoplasty was successfully performed in all patients. The results of phase-contrast cine MRI examinations performed a week after surgery demonstrated an average CSF flow velocity of 4.74±1.77 cm/sec. During the follow-up, intracranial hypertension recurred in two patients in whom CSF flow was not observed in the aqueduct by the phase-contrast cine MRI scan. Aqueduct re-occlusion was revealed by an endoscopic exploration. By measuring the CSF flow velocity, phase-contrast cine MRI accurately identifies aqueduct obstruction. Cine MRI is a nontraumatic, simple and reliable method for determining whether the aqueduct is successfully opened following aqueductoplasty.

  8. Variability interexaminer of chronic apical periodontitis diagnostics in panoramic radiographs

    International Nuclear Information System (INIS)

    Montero Aguilar, Mauricio; Zeledon Mayorga, Rodolfo; Ramirez Mora, Tatiana; Monestel Umana, Silvia

    2009-01-01

    The accuracy of radiological diagnosis of Apical Periodontitis (AP) is reported between examiners with differents levels of clinical experience using panoramic radiographs. 1032 teeth in 41 panoramic radiographs have been diagnosed. The evaluation of the x-rays and radiological diagnosis is performed by three independent dentists for AP to each tooth. The teeth have presented without radiological signs of AP in 96.6%. The number of teeth classified with an uncertain diagnosis of AP at the has been inversely proportional to the number of years of experience of the examiner. The examiner A has been used as a reference and compared the diagnoses of other examiners.The percentage agreement for all teeth was 95% for examiner B and 94% for examiner C. Kappa for all has been of 0.44 for examiner B and 0.43 for examiner C. The different categories were analyzed separately, the inferior teeth and the anterior teeth have obtained the best results. The level of clinical experience of the examiner has been indifferent in the diagnosis of AP in panoramic radiographs; however, it is important experience in the number of radiographs extras that will be needed to give a radiological diagnosis definitive. The panoramic radiographs were reliable diagnostic tools for AP. (author) [es

  9. A study of intraluminal flow in patients with aortic disease by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Kusuoka, Hideo; Kitabatake, Akira; Kamada, Takenobu.

    1990-01-01

    To evaluate the usefulness of cine magnetic resonance (MR) imaging in the diagnosis of aortic disease, we applied cine MR sequences with conventional spin echo (SE) sequence to 15 patients with aortic aneurysm and 5 patients with aortic dissection. ECG gated multi slice SE images (single echo) were obtained in transverse plane and the planes along the long axis of aorta. TE of SE sequence ranged from 15 to 32 msec. Cine MR images were obtained in 17 frames, where TR ranged from 30 to 60 msec and TE from 10 to 22 msec. We got these results as follows. For aortic aneurysm, SE images showed aneurysmal dilatation in thoracic aorta in 9 cases, and in abdominal aorta in 6 cases. Cine MR images showed us the intraluminal flow with high signal intensity. We could differentiate the slow flow image from mural thrombus using SE and cine MR sequences in the same plane. We could evaluate the dynamic flow image within a cavity of aneurysm and in in-flow and out-flow portions of aorta by cine MR imaging. For aortic dissection, SE images delineated the intimal tear and two separated lumens in all cases. We could obtain flow images within true and false lumen by cine MR imaging. The signal intensity within true lumen was higher than that within false lumen. It seemed to be due to the difference of flow velocity and the turbulence within false lumen. Entry to false lumen was seen as the interruption of dissected intima on SE images. Cine MR images clearly depicted the blood flow communication between two lumens through the entry. In 3 of 5 cases the blood flow through the entry was seen in both directions, from true to false lumen in systole and inversely in diastole. Thus, cine MR imaging will add the useful hemodynamic information in the diagnosis of aortic disease by conventional MR imaging. (author)

  10. A EXPERIÊNCIA DE EXTENSÃO NO CINE FREUD, CULTURA E ARTE

    Directory of Open Access Journals (Sweden)

    Caciana Linhares Pereira

    2016-07-01

    Full Text Available O presente trabalho se propõe a apresentar os objetivos gerais do projeto de extensão Cine Freud, Cultura e Arte, assim como algumas reflexões que foram possíveis após nove anos de existência. O projeto visa promover a interlocução entre Arte, Psicanálise e o campo dos Estudos Culturais. Propõe a construção de dispositivos de formação discente que permitam problematizar os fenômenos subjetivos implicados na experiência contemporânea, considerando a diversidade cultural como constitutiva desta experiência. Nesta direção, faz-se fundamental o incentivo e a difusão de obras artísticas e culturais, no sentido de contribuir para a formação artística e crítica dos estudantes e da comunidade em geral, proporcionando o debate, o desenvolvimento do senso crítico e a sensibilização desses sujeitos para com processos afetivos advindos dos mecanismos subjetivos desencadeados pela arte. A problematização do objetivo do projeto considera a participação do seu público-alvo. A partir do levantamento de problemáticas levantadas nos debates realizados no âmbito do projeto, foram apresentadas as linhas gerais que moveram sua discussão e que evidenciam polêmicas importantes no que diz respeito à experiência contemporânea: a desmistificação de alguns aspectos da problemática das perversões e das psicoses e sua relação com as concepções correntes sobre as perversões e a loucura. Palavras-chave: Psicanálise; cultura; cinema   This article aims to present the general objectives of the extension project Cine Freud, Culture and Art, as well as to bring some reflexions about the project in its nine years of existence. Cine Freud aims to promote dialogue between art, psychoanalysis and the field of Cultural Studies. It proposes the construction of student training devices which question the subjective phenomena involved in contemporary experience, considering cultural diversity as constitutive of this experience. In this

  11. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  12. A radiographic study of mental foramen in intraoral radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Jeong Ick; Choi, Karp Shik [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1995-08-15

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  13. Formas de la modernidad en el pensamiento y estilo del cine argentino contemporáneo

    OpenAIRE

    Mutchinick, Mellissa

    2006-01-01

    El proyecto investigativo aborda el tema de las formas en que se presenta el cine moderno en la actualidad, centrando la mirada en el nuevo cine argentino. Es prudente aclarar que utilizamos aquí el término “nuevo” en función de destacar lo contemporáneo, las últimas producciones del cine argentino, y no como calificativo de movimiento. Uno de los procesos que nos proponemos es retomar los conceptos que Deleuze plantea en su categorización del hecho cinematográfico, remitiéndonos a lo que hac...

  14. Mujeres de cine: del glamour de Hollywood a los modelos alternativos

    OpenAIRE

    Caballero Wangüemert, María del Milagro

    2016-01-01

    Es un hecho que el cine ha reflejado la revolución de mujer, familia y sociedad en el siglo XX. El cine nace en masculino: es el hombre quien desempeña las funciones públicas mientras la mujer reina en el ámbito privado, educando desde el hogar a los futuros ciudadanos. ¿Es suficiente ese papel para la mujer actual? Desde luego que no y de ahí su Aasalto al poder: en el caso del cine, la mujer ha pasado de ser objeto de deseo, la protagonista de la historia amorosa en las comedias de Hollywoo...

  15. La esclavitud en la Antigüedad. Historia y cine

    OpenAIRE

    Neira, Luz

    2009-01-01

    Este texto da continuidad a un proyecto que nació en 2002 en el Instituto de Cultura y Tecnología de la Universidad Carlos III de Madrid: las Jornadas de Historia y Cine. Las IV Jornadas de Historia y Cine son las que dan origen a las páginas que aquí les presentamos. Celebradas en noviembre de 2008, decidimos en esta ocasión indagar en las representaciones que el cine ha creado de las vidas pasadas fueran éstas anónimas o públicas, individuales o de sujetos colectivos, para poder analizar...

  16. Del cine documental de Santiago Alvarez al audiovisual cubano contemporáneo

    OpenAIRE

    Acosta Damas, Maribel

    2017-01-01

    El 1960 se funda en Noticiero ICAIC latinoamericano como parte del cine que se fomentó en Cuba posterior a 1959. Este noticiero, dirigido por el gran documentalista cubano Santiago Álvarez, significó una radical transformación estética y ética del cine y dio lugar a un singular fenómeno de empatía entre el público y la emisión del noticiero de cada semana. Asimismo tuvo una notable influencia en el surgimiento noticieros similares en Latinoamérica y de un cine guerrilla de gran ascendencia ...

  17. Cuerpo. Relaciones de poder y sexualidad en el Cine de la Marginalidad.

    OpenAIRE

    Plua Cedeño, María Lorena

    2012-01-01

    El aporte académico de la investigación consiste en situar los sentidos que se pueden transmitir a través del cine, en particular aquel dedicado a mirar el relato cinematográfico desde el comportamiento humano y la vida en sociedad. Igualmente, el trabajo, considera la importancia que se le otorga al cine de autor y a los productos culturales. Esta investigación pretende ser una pauta para encarar el cine desde esta particular taxonomía y generar nuevas discusiones en el ámbito...

  18. Cine militante y videoactivismo: los discursos audiovisuales de los movimientos sociales

    OpenAIRE

    Galán Zarzuelo, Marta

    2012-01-01

    Durante los años sesenta y setenta se generó una producción audiovisual que supuso una ruptura radical con el cine comercial, mostrando alternatividad en todos sus procesos. Los cineastas empezaban a entender el cine como una herramienta de transformación social. Nacía así el cine militante. Estas obras se convierten en un claro referente para las prácticas militantes audiovisuales actuales. La aparición de nuevos actores políticos, la democratización de los medios de producción; la proli...

  19. Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance.

    Science.gov (United States)

    Edelman, Robert R; Serhal, Ali; Pursnani, Amit; Pang, Jianing; Koktzoglou, Ioannis

    2018-02-19

    Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow

  20. Cine Digital y sus Contenedores. Herramientas de Software libre basadas en las Especificaciones DCI

    OpenAIRE

    Romero Gil, Pablo

    2013-01-01

    El Cine Digital es aquel que utiliza la tecnología digital para grabar, distribuir y proyectar películas. En los años 90, el cine comenzó un proceso de transición, del soporte fílmico a la tecnología digital. Pero el salto definitivo se dio con las grandes superproducciones de principios del 2000. Con este cambio de era y debido a la rápida difusión del digital y la proliferación de formatos se creo el DCI (Digital Cinema Initiative), para cambiar el modo en que las personas consumen cine....

  1. El cine bajo presión política: Polonia, 1945-1989*

    OpenAIRE

    Miczka, T. (Tadeusz)

    1998-01-01

    El autor realiza una caracterización de los mecanismos políticos que moldearon el desarrollo del cine político desde la segunda guerra hasta 1989, con la ayuda del concepto de estrategia, señala los roles dominantes en la práctica creadora de dicha época, roles creados por los propios directores de cine. Destaca el hecho de que las estategias de la creación artística en el cine conseguían escapar eficazmente del corsé ideolófico impuesto, e incluso se convirtieron en instrumentos de lucha pol...

  2. La globalización y exhibición del cine mexicano

    OpenAIRE

    Ruiz Guzmán, Narce Dalia

    2011-01-01

    El neoliberalismo económico instituido en México a partir de la firma del Tratado de Libre Comercio, la disolución de la compañía distribuidora de cine que pertenecía al Estado Mexicano (COTSA) y el crecimiento de las salas múltiplex en la década de los noventa, marcó el destino de la exhibición del cine mexicano. La globalización afecta los contenidos audiovisuales y el cine mexicano actualmente ha tenido que buscar espacios para lograr encontrarse con sus espectadores. La industria del c...

  3. Reflections on the role of consultant radiographers in the UK: What is a consultant radiographer?

    International Nuclear Information System (INIS)

    Booth, L.; Henwood, S.; Miller, P.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK. Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore two consultants were interviewed only once. The remaining six consultants were interviewed twice over a 12 month period. Findings: The data presented in this paper explores the nature of the role, differences between roles, the four domains of practice, and how the role fits into local organisational structures. The study shows wide variation in the types of roles undertaken, reflecting that the creation of these roles were in response to local clinical need and often related to an individual practitioner's skills. The broad scope of the role was shown across all the consultants, with evidence of roles developing into new areas of service delivery. Conclusions: The paper offers insight into the role(s) of consultant radiographers in the UK. The range and scope of their practice is extensive, with much variation. It is evident that the clinical aspect of the role dominates, with research being the least supported domain of practice. There remains a lack of clarity around the role, with concerns about remuneration and other limitations that may restrict the role developing further. - Highlights: • This paper shows the variation in roles between consultant radiographers. • The commonality with medical roles is highlighted. • Problem solving is identified as a core skill in consultant radiography. • Consultants offered evidence of the roles developing service provision. • While all four domains of practice are covered, research is the least well supported.

  4. Respiratory repercussions of gastroesophageal reflux and cine-esophagogastroscintigraphy

    International Nuclear Information System (INIS)

    Guillemeteau, C.; Saudubray, F.; Guillet, J.

    1985-01-01

    Asthma and recurrent bronchopneumopathies in children are often associated with gastroesophageal reflux. Cine-esogastroscintigraphy is proposed for demonstrating reflux and establishing its direct or indirect responsibility in respiratory disease. 133 patients aged 5 months to 16 years were studied. Reflux was found in 65.5% of cases, either severe (44.4% of cases) or minor (21.1%). Episodes of reflux produced respiratory manifestations in 7% of patients. Inhalation of refluxed material was proved in 3% by demonstration of pulmonary contamination. Sensitivity of cine-esophagogastroscintigraphy is comparable to that of esophageal pH measurement for detection of reflux. It does not require positioning of a probe in the esophageal lumen. It provides quantitative parameters on esophageal transit, reflux and gastric voiding, and demonstrates pulmonary contamination. It is easy to perform and can be readily included in an outpatient clinic workup. Its sensitivity and reliability make it a useful tool for evaluation of therapeutic efficiency. The interlocking of various physiopathologic factors contributes to the polymorphism of respiratory manifestations of reflux [fr

  5. Respiratory repercussions of gastroesophageal reflux and cine-esophagogastroscintigraphy

    International Nuclear Information System (INIS)

    Guillemeteau, C.; Saudubray, F.; Guillet, J.

    1984-01-01

    Asthma and recurrent bronchopneumopathies in children are often associated with gastroesophageal reflux. Cine-esogastroscintigraphy is proposed for demonstrating reflux and establishing its direct or indirect responsibility in respiratory disease. 133 patients aged 5 months to 16 years were studied. Reflux was found in 65.5% of cases, either severe (44.4% of cases) or minor (21.1%). Episodes of reflux produced respiratory manifestations in 7% of patients. Inhalation of refluxed material was proved in 3% by demonstration of pulmonary contamination. Sensitivity of cine-esophagogastroscintigraphy is comparable to that of esophageal pH measurement for detection of reflux. It does not require positioning of a probe in the esophageal lumen. It provides quantitative parameters on esophageal transit, reflux and gastric voiding, and demonstrates pulmonary contamination. It is easy to perform and can be readily included in an outpatient clinic workup. Its sensitivity and reliability make it a useful tool for evaluation of therapeutic efficiency. The interlocking of various physiopathologic factors contributes to the polymorphism of respiratory manifestations of reflux [fr

  6. Presenting CineGlobe Estival! | 6 - 10 July

    CERN Multimedia

    2016-01-01

    Join CineGlobe under a projected starry sky for a film festival and games with a neuroscience twist.   The 6th edition of the CineGlobe International Film Festival at CERN will take place during the first week of July 2016 (on the Globe grounds at CERN, from Wednesday 6 to Friday 8 July) and then during the Nuit de la Science (at the Museum of the History of Science, on July 9 and 10). The festival will include an open-air cinema, film projections in the Globe of Science and Innovation at CERN, the interactive Emotional Circus (carnival-inspired games played with just the participant’s brainwaves) and a special sci-fi edition of the 48 Hour Film Project. The full program will target people of all ages with fun and informative activities such as children’s films in the Minima Cinema, and a workshop on the creation of a pinhole camera with an empty Tetra-Pak milk carton. Practical information: Entry is free. All films in English and French. Onsite food trucks at the G...

  7. Cine-MR imaging of valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Jin; Kim, Woo Sung; Park, Hyun Wuk; Cho, Zang Hee [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    1989-04-15

    Cine-MR imaging was done in 2 normal persons and 9 patients of valvular heart disease with 2.0 T superconducting MR system (Spectro-2000; GoldStar, Korea). The MRI was undertaken using gradient echo technique with small flip angle. Repetition time (TR) was 34 msec, and echo time (TE), 18 msec. In most cases, 20 to 30 frames could be obtained during one cardiac cycle. With normal heart, high signal intensity was identified in the blood filled cardiac chambers. Transient signal void was observed near tricuspid, mitral and aortic valves due to the turbulences induced by valve opening or closure. In 6 cases of mitral valvular disease, mitral valve was identified in all cases. The valvular motion was limited revealing doming toward cardiac apex during diastole. Signal void was evident in pansystolic phase of left ventricle in all cases. Evidence of combined aortic or tricuspid valve disease were also demonstrated, revealing signal void in the corresponding cardiac chambers. Cine-MRI seemed to be not only a good non-invasive diagnostic modality for the valvular heart disease, but also an accurate modality for cardiac functional evaluation.

  8. El rostro del suicida en el espejo del cine

    Directory of Open Access Journals (Sweden)

    Beatriz OGANDO DÍAZ

    2016-09-01

    Full Text Available El suicidio es una de las formas de morir más escondida y silenciada en nuestra sociedad. A la vez es una de las que genera mayor sufrimiento, previo en quienes se escapan de la vida y posterior por la culpa que atormenta a los supervivientes. Es además una de las causas más relevante de muerte violenta en ado- lescentes y ancianos. Sobre ella pesa cierto tipo de conspiración de silencio social que quizá pueda ser abordado a través del cine. Son muchas las películas que se han ocupado de este tema, aunque no siem- pre de modo central. En muchas de ellas el suicidio de uno de los personajes determina todo el desarro- llo posterior de la trama o le pone el broche final a la historia. En otras se intenta explicar lo inexplicable: por qué alguien puede preferir morir a seguir viviendo. Incluso algunas películas se han acercado a este drama vital enfocándolo desde el humor.La facilidad del cine en mostrar el mundo emocional de sus personajes y su capacidad de hacer eviden- tes elementos de la realidad que pueden pasar desapercibidos sugieren que puede ser un buen vehícu- lo para intentar comprender a las personas que deciden saltar sobre su propia sombra y morir antes de tiempo.

  9. “Delicias holandesas” dirigidas por mujeres: cine contra estereotipos

    Directory of Open Access Journals (Sweden)

    Fernández Rodríguez, Carolina

    2012-12-01

    Full Text Available This paper offers a brief history of women filmmakers in The Netherlands from the 1920s to the present, in an attempt to achieve two goals. The first aim is to show that despite the scarcity of women directors in the histories of the cinema of the Netherlands, there are many women in the Dutch film industry, particularly so given its small size in the European context. Secondly, this paper aims to show that many of the myths that have been commonly associated with Dutch cinema, such as its inability to produce good fiction films or to handle important socio-political issues, can be easily dismantled after seeing the work of Dutch women filmmakers. Although it is certainly much easier to find documentaries than dramas among their works, it is nevertheless true that they have also produced many of the latter. Moreover, in both categories they have explored complex and controversial themes that are highly relevant to their society, as well as opening up new thematic paths along which male directors had never travelled. Issues related to the new national identities resulting from the multicultural contexts of present-day Europe are among the former, while the latter is best represented by topics traditionally dealt with by feminism, such as the question of abortion, rape or women’s submission in patriarchal societies, among others.

    Este artículo ofrece una breve historia del trabajo realizado por las directoras de cine de los Países Bajos desde los años veinte del pasado siglo hasta la actualidad con el fin de lograr dos objetivos. En primer lugar, se trata de probar que, pese a la escasa presencia de directoras holandesas en las historias sobre cine holandés, su número es muy elevado, especialmente si consideramos que la industria cinematográfica de su país es relativamente pequeña. En segundo lugar, se busca demostrar que muchos de los mitos que se han asumido como ciertos sobre el cine holandés, como su incapacidad para hacer

  10. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  11. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  12. Radiographic arthrosis after elbow trauma: interobserver reliability.

    Science.gov (United States)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David

    2012-04-01

    This study measured observer variation in radiographic rating of elbow arthrosis. Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint; grade 1, slight joint-space narrowing with minimum osteophyte formation; grade 2, moderate joint-space narrowing with moderate osteophyte formation; and grade 3, severe degenerative change with gross destruction of the joint). The kappa multirater measure (κ) was used to estimate reliability between observers, with 0 indicating no agreement above chance, and 1 indicating perfect agreement. There was fair agreement in arthrosis ratings between surgeons. Surgeons with more than 10 years of experience had greater agreement than did surgeons with less experience, and surgeons who treated more than 10 elbow fractures per year had better agreement than did those treating fewer fractures. In post hoc analyses, 2 simplified binary rating systems (eg, "none or mild" vs "moderate or severe" arthrosis) resulted in moderate agreement among observers. The 4 grades of the Broberg and Morrey classification system have only fair interobserver reliability that is influenced by subspecialty and experience. Binary rating systems might be more reliable. Diagnostic III. Copyright © 2012 American Society for Surgery of the Hand. All rights reserved.

  13. El cine como reivindicación de la memoria individual y colectiva. Directoras húngaras del periodo comunista

    Directory of Open Access Journals (Sweden)

    Cruzado Rodríguez, Ángeles

    2012-12-01

    Full Text Available This article takes a look at the most prominent women filmmakers of communist Hungary, emphasising both their common features and specificities, in order to highlight their contribution to Hungarian film history. In general, they are transgressive filmmakers, having broken the conventions established by the communist regime and tried to offer a new vision of history, based on their own experience.

    El artículo realiza un acercamiento a las directoras de cine más relevantes de la etapa comunista en Hungría, destacando sus características comunes así como las especificidades de cada una, en un intento por poner en valor su contribución a la historia del cine de su país. Por lo general, se trata de mujeres transgresoras, que han roto las convenciones establecidas por el régimen y han tratado de ofrecer una nueva visión de la historia, partiendo de su propia experiencia.

  14. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  15. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images

    Energy Technology Data Exchange (ETDEWEB)

    Zweerink, Alwin; Allaart, Cornelis P.; Wu, LiNa; Beek, Aernout M.; Rossum, Albert C. van; Nijveldt, Robin [VU University Medical Center, Department of Cardiology, and Institute for Cardiovascular Research (ICaR-VU), Amsterdam (Netherlands); Kuijer, Joost P.A. [VU University Medical Center, Department of Physics and Medical Technology, Amsterdam (Netherlands); Ven, Peter M. van de [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Meine, Mathias [University Medical Center, Department of Cardiology, Utrecht (Netherlands); Croisille, Pierre; Clarysse, Patrick [Univ Lyon, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, Saint-Etienne (France)

    2017-12-15

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. (orig.)

  16. [X-ray radiographic imaging technique with high dynamic range].

    Science.gov (United States)

    Liu, Bin; Wang, Li-Ming; Su, Xin-Yan

    2014-04-01

    In conventional X-ray radiographic imaging system with a fixed energy parameter, the acquired X-ray images are usually overexposed and have no useful information available. It is due to some constraints, like special structure of component, different attenuation coefficients of materials and dynamic range of optoelectronic devices. When maximum of transmitted X-ray luminous exceed capacity limitation of X-ray radiographic imaging system in one scene, the device up to saturate. Also when minimum of transmitted X-ray luminous is below the thermal noise level of imaging system, no useful information is available for imaging. To solve the problem of difficulties in acquiring transmitted X-ray luminous in a wide dynamic range by conventional X-ray radiographic imaging system, we put forward a new X-ray radiographic imaging technique with high dynamic range based on adjusting tube voltage. In the article, the influence by charge capacity of X-ray radiographic imaging system on effective irradiating thickness is analyzed. Through experiments of some standard samples, we gained the relationship between voltage range of X-ray tube and materials or structure of component for best testing sensitivity. Then we put forward an adjusting strategy of tube voltage and effective subgraphs extraction method from acquired raw X-ray images. By the mentioned method, we carried out X-ray radiographic imaging experiments with high dynamic range for components with thickness from 0 to 20 mm. The results show that X-ray radiographic imaging technique with high dynamic range is effective to realize imaging for some components with different thickness. It is available for us to find more detailed projection information from fusion images.

  17. Cine-magnetic resonance imaging evaluation of communication between middle cranial fossa arachnoid cysts and cisterns

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Shiomi, Kazuaki; Fujimoto, Takatoshi; Otsuka, Hiroyuki; Takeuchi, Hiroshi; Taoka, Toshiaki.

    1996-01-01

    Cine-magnetic resonance (MR) imaging examinations were performed in 10 patients with middle cranial fossa arachnoid cysts to evaluate communication between the cysts and the normal cerebrospinal fluid (CSF) space. Eight of 10 patients were evaluated by time of flight cine-MR imaging, and two by phase contrast cine-MR imaging. Two patients underwent membranectomy of the cysts, and were evaluated both pre-and postoperatively. Computed tomography cisternography was used to confirm communication between the cysts and the surrounding cisterns. Pulsatile fluid motion within the cysts was present in all patients. However, marked fluid motion and jet flow between the cysts and the surrounding cisterns were only observed in communicating cysts. In the two patients who underwent membranectomy, postoperative examination found greater fluid motion and jet flow not previously present. Cine-MR imaging demonstration of marked pulsatile fluid motion accompanied by jet flow suggests that a cyst communicates with the normal CSF space. (author)

  18. Myocardial strain assessment by cine cardiac magnetic resonance imaging using non-rigid registration.

    Science.gov (United States)

    Tsadok, Yossi; Friedman, Zvi; Haluska, Brian A; Hoffmann, Rainer; Adam, Dan

    2016-05-01

    To evaluate a novel post-processing method for assessment of longitudinal mid-myocardial strain in standard cine cardiac magnetic resonance (CMR) imaging sequences. Cine CMR imaging and tagged cardiac magnetic resonance imaging (TMRI) were performed in 15 patients with acute myocardial infarction (AMI) and 15 healthy volunteers served as control group. A second group of 37 post-AMI patients underwent both cine CMR and late gadolinium enhancement (LGE) CMR exams. Speckle tracking echocardiography (STE) was performed in 36 of these patients. Cine CMR, TMRI and STE were analyzed to obtain longitudinal strain. LGE-CMR datasets were analyzed to evaluate scar extent. Comparison of peak systolic strain (PSS) measured from CMR and TMRI yielded a strong correlation (r=0.86, pcine CMR data. The method was found to be highly correlated with strain measurements obtained by TMRI and STE. This tool allows accurate discrimination between different transmurality states of myocardial infarction. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Cine MRI of swallowing in patients with advanced oral or oropharyngeal carcinoma: a feasibility study

    NARCIS (Netherlands)

    Kreeft, Anne Marijn; Rasch, Coen R. N.; Muller, Sara H.; Pameijer, Frank A.; Hallo, Eeke; Balm, Alfons J. M.

    2012-01-01

    Treatment of oral and oropharyngeal cancer may cause dysphagia. Purpose is to examine whether cine magnetic resonance imaging (MRI) yields additional information compared to standard examination in the evaluation of posttreatment dysphagia and mobility of oral and oropharyngeal structures.

  20. EL CINE ESPAÑOL COMO FUENTE DOCUMENTAL PARA EL ESTUDIO DE LOS BARRIOS MARGINALES

    Directory of Open Access Journals (Sweden)

    Aramis López Juan

    2008-01-01

    Full Text Available El cine como arte nuevo y técnico se instala en una sociedad moderna que tiene una percepción del mundo basada en la imagen. El cine y la fotografía son los introductores de esta modalidad perceptiva de la modernidad. Esta experiencia sensorial sitúa al hombre en un universo más amplio. El hombre contemporáneo comprende los mecanismos representativos del cine, sus códigos, sus metáforas e iconos. El cine ha nacido al mismo tiempo que los abuelos de los espectadores actuales, ha crecido con sus padres, y es conocido y comprendido universalmente

  1. Cine infantil: aproximación a una definición

    Directory of Open Access Journals (Sweden)

    María del Mar Rodríguez Rosell

    2010-05-01

    Full Text Available La existencia de un conglomerado de teorías referentes al cine destinado para niños, junto a la diversidad de parámetros que giran en torno al cine infantil y a la falta de consenso entre autores a la hora de hablar de géneros cinematográficos –Sánchez Noriega (2002, Huerta Floriano (2005, Martínez Barnuevo (2008 ente otros–, nos hacen plantearnos una nueva revisión del cine para los más pequeños. De este modo, con una metodología de análisis puramente cualitativa, se aglutinan teorías y se aportan ideas, características y elementos que nos llevan a perfilar una definición lo más concreta posible de lo que hoy podemos denominar “Cine Infantil”.

  2. Comparisons of NIF convergent ablation simulations with radiograph data.

    Science.gov (United States)

    Olson, R E; Hicks, D G; Meezan, N B; Koch, J A; Landen, O L

    2012-10-01

    A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

  3. Usefulness of true FISP cine MR imaging in patients with poor cardiac function

    International Nuclear Information System (INIS)

    Sakuma, Toshiharu; Yamada, Naoaki; Motooka, Makoto; Enomoto, Naoyuki; Maeshima, Isamu; Matsuda, Kazuhide; Urayama, Shinichi; Ikeo, Miki

    2002-01-01

    This study was done to assess the value of True FISP cine in patients with poor cardiac function. True FISP cine and FLASH cine imaging were performed on a 1.5 T machine. Both short axis and horizontal long axis imaging sections were used. The imaging sections used a Matrix (120 x 128), FOV (24 x 32 cm), and had a slice thickness of 8 mm. The imaging time for True FISP cine was 8 heart beats and 17 heart beats for FLASH cine. The contrast-to-noise ratio between the blood and myocardium (CNR) was measured at enddiastole and endsystole. The subjects in the study were 10 healty volunteers (average age 26.5±3.2 years) and 12 patients with hypofunction (average age 53.9±13.2 years). In the volunteers, the CNR of the short axis imaging was similar in both True FISP (24.6±3.7) and FLASH (23.4±5.9). In the patients with poor cardiac function however, the CNR of True FISP was larger than FLASH in both the short and long axis. In the short axis (22.7±6.1 vs. 17.9±5.3, P<0.01) and in the long axis (17.4±4.3 vs. 9.3±4.0, P<0.01). We conclude that True FISP cine has a higher contrast in a shorter imaging time than FLASH cine. True FISP cine is especially useful in patients with poor cardiac function. (author)

  4. Feasibility of vocal fold abduction and adduction assessment using cine-MRI.

    Science.gov (United States)

    Baki, Marina Mat; Menys, Alex; Atkinson, David; Bassett, Paul; Morley, Simon; Beale, Timothy; Sandhu, Guri; Naduvilethil, Georgekutty; Stevenson, Nicola; Birchall, Martin A; Punwani, Shonit

    2017-02-01

    Determine feasibility of vocal fold (VF) abduction and adduction assessment by cine magnetic resonance imaging (cine-MRI) METHODS: Cine-MRI of the VF was performed on five healthy and nine unilateral VF paralysis (UVFP) participants using an axial gradient echo acquisition with temporal resolution of 0.7 s. VFs were continuously imaged with cine-MRI during a 10-s period of quiet respiration and phonation. Scanning was repeated twice within an individual session and then once again at a 1-week interval. Asymmetry of VF position during phonation (VF phonation asymmetry, VFPa) and respiration (VF respiration asymmetry, VFRa) was determined. Percentage reduction in total glottal area between respiration and phonation (VF abduction potential, VFAP) was derived to measure overall mobility. An un-paired t-test was used to compare differences between groups. Intra-session, inter-session and inter-reader repeatability of the quantitative metrics was evaluated using intraclass correlation coefficient (ICC). VF position asymmetry (VFPa and VFRa) was greater (p=0.012; p=0.001) and overall mobility (VFAP) was lower (p=0.008) in UVFP patients compared with healthy participants. ICC of repeatability of all metrics was good, ranged from 0.82 to 0.95 except for the inter-session VFPa (0.44). Cine-MRI is feasible for assessing VF abduction and adduction. Derived quantitative metrics have good repeatability. • Cine-MRI is used to assess vocal folds (VFs) mobility: abduction and adduction. • New quantitative metrics are derived from VF position and abduction potential. • Cine-MRI able to depict the difference between normal and abnormal VF mobility. • Cine-MRI derived quantitative metrics have good repeatability.

  5. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    Science.gov (United States)

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; Pcine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; Pcine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; Pcine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  6. Reading screening mammograms – Attitudes among radiologists and radiographers about skill mix

    International Nuclear Information System (INIS)

    Johansen, Lena Westphal; Brodersen, John

    2011-01-01

    Introduction: Because of shortage of personnel for the Danish mammography screening programme, the aim of this study was to investigate the attitudes of radiologists and radiographers towards a future implementation of radiographers reading screening mammograms. Materials and methods: Seven combined phenomenological and hermeneutical interviews with radiographers and radiologists were performed. Stratified selection was used for sampling of informants. The interviews were analysed against theory about quality, organization and profession. Results: Quality related possibilities: radiographers do routinely measure the performance quality, radiographers obtain sufficient reading qualifications, and skill mix improves quality. Quality related obstacles: radiologists do not routinely measure performance quality. Organization related possibilities: shortage of radiologists, positive attitudes of managers, and improved working relations. Organization related obstacles: shortage of radiographers and negative attitudes of managers. Professional related possibilities: positive experience with skill mix. Professional related obstacles: worries about negative consequences for the training of radiologists, and resistance against handing over tasks to another profession. Conclusion: Attitudes towards radiographers reading screening mammograms are attached to either quality-, organisational or professional perspectives. Radiographers are capable of learning to read mammograms at sufficient performance level but routine measurement of performance quality is essential. Resistance against skill mix may be caused by an emotionally conditioned fear of losing demarcations. The main motive for skill mix is improvement of the utilization of resources. No evidence was found regarding the organisational and financial consequences of skill mix. Despite of this all radiologists and radiographers experienced with skill mix were strong advocates for reading radiographers.

  7. Radiographic findings of Proteus Syndrome

    Directory of Open Access Journals (Sweden)

    Nishant Mukesh Gandhi, MD

    2014-01-01

    Full Text Available The extremely rare Proteus Syndrome is a hamartomatous congenital syndrome with substantial variability between clinical patient presentations. The diagnostic criteria consist of a multitude of clinical findings including hemihypertrophy, macrodactyly, epidermal nevi, subcutaneous hamartomatous tumors, and bony abnormalities. These clinical findings correlate with striking radiographic findings.

  8. Radiographic findings of Proteus Syndrome

    Science.gov (United States)

    Gandhi, Nishant Mukesh; Davalos, Eric A.; Varma, Rajeev K.

    2015-01-01

    The extremely rare Proteus Syndrome is a hamartomatous congenital syndrome with substantial variability between clinical patient presentations. The diagnostic criteria consist of a multitude of clinical findings including hemihypertrophy, macrodactyly, epidermal nevi, subcutaneous hamartomatous tumors, and bony abnormalities. These clinical findings correlate with striking radiographic findings. PMID:27186241

  9. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  10. Espectadores en 3D: ¿El futuro del cine?

    Directory of Open Access Journals (Sweden)

    Díaz Gandasegui, Vicente

    2011-04-01

    Full Text Available This paper analyses the reintroduction of 3D to the big screen, this time, due to the digital technology and the polarization of the image, the focal depth has become more credible and the interface, in spite of still being present, is more comfortable and effective. The spectacular images attract the spectator to the cinema and captivate them with technological visual development. Simultaneously, 3D is a useful tool to solve contemporary cinema problems with piracy and competition with other media. However, the big question that 3D has to solve is whether the new technology will join the large list of fiascos of the 70’s and 80’s, trying to transform the way of seeing the image, or if it will be a step closer to virtual reality and a cinema of immersion and total interaction.

    El presente artículo analiza la (reintroducción del 3D en nuestras pantallas de cine. Esta vez, gracias a la tecnología digital y a la polarización de la imagen, la profundidad de campo se hace mas creíble y la interfaz, a pesar de seguir presente, ha ganado en comodidad y efectividad. La espectacularidad de las imágenes es el mayor reclamo que hoy presenta el 3D para atraer al espectador a las salas de cine y fascinarle con el desarrollo tecnológico. Al mismo tiempo, el 3D es una herramienta útil para solucionar los problemas surgidos en la industria cinematográfica a raíz de la evolución de la pirateria y la cada vez más compleja competición con otros medios. La gran duda que plantea el 3D es si se sumará a la larga lista de fracasos de los años 70 y 80 por intentar transformar la forma de ver la imagen o supondrá un paso adelante en la pretensión por acercarnos a la realidad virtual y un cine de inmersión e interacción total.

  11. Atrapar la emoción: Hollywood y el Grupo Dogma 95 ante el cine digital

    Directory of Open Access Journals (Sweden)

    Marzal Felici, José Javier

    2003-03-01

    Full Text Available La tecnología del cine digital representa, no sólo nuevas formas de gestionar y organizar la producción cinematográfica, sino sobre todo abre la puerta para la exploración de nuevas formas de construcción del relato. En primer lugar, realizaremos una valoración general de lo que está suponiendo la «migración digital» para la industria del cine. Esto pasa por reflexionar sobre la importancia de la tecnología en la historia del cine y revisar las transformaciones que se están produciendo en la actualidad. Veremos cómo la construcción de mundos virtuales en el cine más industrial se enfrenta al reto de la «captura» de la emoción. Finalizaremos este bloque con una caracterización del cine hollywoodiense que constituye un «cine de atracciones»...

  12. Three-dimensional cine MRI in free-breathing infants and children with congenital heart disease

    International Nuclear Information System (INIS)

    Seeger, Achim; Fenchel, Michael C.; Kramer, Ulrich; Bretschneider, Christiane; Doering, Joerg; Claussen, Claus D.; Miller, Stephan; Martirosian, Petros; Sieverding, Ludger

    2009-01-01

    Patients with congenital heart disease frequently have complex cardiac and vascular malformations requiring detailed non-invasive diagnostic evaluation including functional parameters. To evaluate the morphological and functional information provided by a novel 3-D cine steady-state free-precession (SSFP) sequence. Twenty consecutive children (mean age 2.2 years, nine boys) were examined using a 1.5-T MR system including 2-D cine gradient-recalled-echo sequences, static 3-D SSFP and 3-D cine SSFP sequences. Measurement of ventricular structures and volumes showed close agreement between the 3-D cine SSFP sequence and the 2-D cine gradient-recalled-echo and static 3-D SSFP sequences (left ventricular volumes mean difference 1.0-1.9 ml and 8.8-11.4%, respectively; right ventricular volumes 1.7-2.1 ml and 9.9-16.9%, respectively). No systematic bias was observed. 3-D cine MRI provides anatomic as well as functional information with sufficient spatial and temporal resolution in free-breathing infants with congenital heart disease. (orig.)

  13. Free-breathing cine CT for the diagnosis of tracheomalacia in young children

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2013-01-01

    Tracheomalacia is characterized by excessive expiratory collapse of the trachea. To investigate the accuracy of free-breathing cine CT for diagnosis of tracheomalacia in young children with bronchoscopy as reference standard. In a retrospective study (May 2001-July 2008), a patient group (n = 27) of children with bronchoscopic evidence of tracheomalacia, and a control group (n = 320) underwent free-breathing cine CT. The tracheal shape on free-breathing cine CT was classified as round, lunate, elongated or crescentic. Cross-sectional area change of the trachea and age were compared between the groups and the diagnostic performance of free-breathing cine CT for tracheomalacia was evaluated. The patient group showed significantly greater cross-sectional area change of the trachea (57.2% ± 22.2% vs. 10.6% ± 11.2%, P < 0.001) than the control group. If a cross-sectional area change of the trachea of 31.6% was used as a cut-off value for the diagnosis of tracheomalacia, the sensitivity, specificity and accuracy of cine CT were 96.3% (26/27), 97.2% (311/320) and 97.1% (337/347), respectively. If a crescentic shape during the expiratory phase was used, the sensitivity, specificity and accuracy were 51.9% (14/27), 98.8% (316/320) and 95.1% (330/347), respectively. Free-breathing cine CT has potential to provide the diagnosis of tracheomalacia in young children. (orig.)

  14. The Role of Cine Flow Magnetic Resonance Imaging in Patients with Chiari 0 Malformation.

    Science.gov (United States)

    Ozsoy, Kerem Mazhar; Oktay, Kadir; Cetinalp, Nuri Eralp; Gezercan, Yurdal; Erman, Tahsin

    2018-01-01

    To define the role of phase-contrast cine magnetic resonance imaging (MRI) in deciding the therapeutic strategy and underlying pathophysiology resulting in syrinx formation in patients with Chiari type 0 malformation. Seven patients who were admitted to our clinic with the diagnosis of Chiari 0 malformation from January 2005 to July 2016 were enrolled in the study. All patients underwent a detailed preoperative neurological examination. Entire neuroaxis MRI and phase-contrast cine MRI were obtained preoperatively and postoperatively. Seven patients (5 female and 2 male) with Chiari type 0 malformation fulfilled the inclusion criteria. All of the patients had absent cine flow at the craniovertebral junction except two patients. These five patients underwent surgical interventions; suboccipital decompression and duraplasty. All of them showed both clinical and radiological improvement in the postoperative period. Cine flow MRI appears to be a useful tool in the management of patients with Chiari 0 malformation. There was a good correlation between the clinical presentation and cine flow preoperatively, and between clinical improvement and cine flow in the postoperative period.

  15. Peristalsis gap sign at cine magnetic resonance imaging for diagnosing strangulated small bowel obstruction. Feasibility study

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, T.C.; Haradome, Hiroki

    2011-01-01

    The aim of this study was to determine the feasibility of cine magnetic resonance imaging (MRI) for diagnosing strangulated small bowel obstruction (SBO). This study included 38 patients with clinically confirmed SBO who had undergone cine MRI. Cine MRI scans were evaluated regarding the presence of the 'peristalsis gap sign' (referring to an akinetic or severely hypokinetic closed loop), indicating strangulation. Computed tomography (CT) was performed in 34 of 38 patients with (n=25) or without (n=9) contrast enhancement. CT images were evaluated using a combination of criteria (presence of hyperattenuation, poor contrast enhancement, mesenteric edema, wall thickening, massive ascites) indicating strangulation. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of cine MRI and CT for the diagnosis of strangulation were calculated and compared using surgical findings and the clinical course as the reference standard. Sensitivity, specificity, PPV, and NPV of cine MRI were 100%, 92.9%, 83.3%, and 100%, respectively; and those of CT (of which 26.5% was performed without contrast enhancement) were 66.7%, 92.0%, 75.0%, and 88.5%, respectively. There was no significant difference in diagnostic accuracy between the two methods (P=0.375). Cine MRI is a feasible and promising technique for diagnosing strangulation. (author)

  16. Motion Correction using Coil Arrays (MOCCA) for Free-Breathing Cardiac Cine MRI

    Science.gov (United States)

    Hu, Peng; Hong, Susie; Moghari, Mehdi H.; Goddu, Beth; Goepfert, Lois; Kissinger, Kraig V.; Hauser, Thomas H.; Manning, Warren J; Nezafat, Reza

    2014-01-01

    In this study, we present a motion compensation technique based on coil arrays (MOCCA) and evaluate its application in free-breathing respiratory self-gated cine MRI. MOCCA takes advantages of the fact that motion-induced changes in k-space signal are modulated by individual coil sensitivity profiles. In the proposed implementation of MOCCA self-gating for free-breathing cine MRI, the k-space center line is acquired at the beginning of each k-space segment for each cardiac cycle with 4 repetitions. For each k-space segment, the k-space center line acquired immediately before was used to select one of the 4 acquired repetitions to be included in the final self-gated cine image by calculating the cross-correlation between the k-space center line with a reference line. The proposed method was tested on a cohort of healthy adult subjects for subjective image quality and objective blood-myocardium border sharpness. The method was also tested on a cohort of patients to compare the left and right ventricular volumes and ejection fraction measurements with that of standard breath-hold cine MRI. Our data indicate that the proposed MOCCA method provides significantly improved image quality and sharpness compared to free-breathing cine without respiratory self-gating, and provides similar volume measurements compared with breath-hold cine MRI. PMID:21773986

  17. Evaluation of atrial, ventricular and atrioventricular septal defects by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Akagi, Teiji; Kato, Hirohisa; Kiyomatsu, Yumi; Saiki, Kuninobu; Suzuki, Kazushige; Eto, Takaharu

    1992-01-01

    Cine magnetic resonance imaging (MRI) was performed on 20 patients (mean age: 5.3±4.4 years) with atrial, ventricular, or atrioventricular septal defects for evaluation of cardiac structure and blood flow. Prior to cine MRI, electrocardiographycally gated MRI using multislice scquisition was performed on all patients to localize optimal slice location. Cine-MRI was obtained with a 30 deg flip angle, 15 msec echo time, and 30 msec pulse repetition time, on a 256 x 256 or 128 x 128 acquisition matrix. Abnormalities of cardiac structure were well defined in all patients by gated cardiac imaging. In 18 of the 20 patients, cine-MRI was able to detect shunt flow, visualized as a low intensity signal in comparison with the surrounding blood flow. Cine-MRI can provide not only accurate anatomy of cardiac structures but functional assessment of the cardiac chamber, wall topology and flow relations. Cine-MRI will become an important noninvasive technique for assessment of anatomy and physiology in congenital heart disease. (author)

  18. Value of cine MRI for better visualization of the proximal small bowel in normal individuals

    International Nuclear Information System (INIS)

    Torkzad, Michael R.; Blomqvist, Lennart; Vargas, Roberto; Tanaka, Chikako

    2007-01-01

    While enteroclysis seems to be the most efficacious method in achieving bowel distension, enterographic methods have become widespread due to the unpleasantness of enteroclysis and the radiation involved with positioning the catheter. Cine images in MRI can be done without radiation. Our aim is to see if and how cine MR imaging can improve visualization of bowel loops by capturing them while distended. Ten healthy individuals were asked to drink up to 2,000 ml of an oral solution made locally over a 60-min period. Then they underwent MRI using coronal balanced fast field echo (b-FFE) covering small bowel loops. If the initial exam revealed collapsed bowel loops an additional 50 mg of erythromycine was given intravenously with the subject still in the scanner and then cine imaging was performed. The degree of distension of different segments of the small bowel was measured before and after cine imaging and compared. The distension score was significantly higher after addition of the cine images as well, being only significant for depiction of the duodenum and jejunum. Our preliminary study suggests that cine MRI can give better image depiction of the proximal small bowel in healthy volunteers, perhaps circumventing the need for enteroclysis in some cases. There is a need for validation of these results in patients with small bowel disease. (orig.)

  19. SU-E-J-234: Application of a Breathing Motion Model to ViewRay Cine MR Images

    International Nuclear Information System (INIS)

    O’Connell, D. P.; Thomas, D. H.; Dou, T. H.; Lamb, J. M.; Yang, L.; Low, D. A.

    2015-01-01

    Purpose: A respiratory motion model previously used to generate breathing-gated CT images was used with cine MR images. Accuracy and predictive ability of the in-plane models were evaluated. Methods: Sagittalplane cine MR images of a patient undergoing treatment on a ViewRay MRI/radiotherapy system were acquired before and during treatment. Images were acquired at 4 frames/second with 3.5 × 3.5 mm resolution and a slice thickness of 5 mm. The first cine frame was deformably registered to following frames. Superior/inferior component of the tumor centroid position was used as a breathing surrogate. Deformation vectors and surrogate measurements were used to determine motion model parameters. Model error was evaluated and subsequent treatment cines were predicted from breathing surrogate data. A simulated CT cine was created by generating breathing-gated volumetric images at 0.25 second intervals along the measured breathing trace, selecting a sagittal slice and downsampling to the resolution of the MR cines. A motion model was built using the first half of the simulated cine data. Model accuracy and error in predicting the remaining frames of the cine were evaluated. Results: Mean difference between model predicted and deformably registered lung tissue positions for the 28 second preview MR cine acquired before treatment was 0.81 +/− 0.30 mm. The model was used to predict two minutes of the subsequent treatment cine with a mean accuracy of 1.59 +/− 0.63 mm. Conclusion: Inplane motion models were built using MR cine images and evaluated for accuracy and ability to predict future respiratory motion from breathing surrogate measurements. Examination of long term predictive ability is ongoing. The technique was applied to simulated CT cines for further validation, and the authors are currently investigating use of in-plane models to update pre-existing volumetric motion models used for generation of breathing-gated CT planning images

  20. Reading screening mammograms - Attitudes among radiologists and radiographers about skill mix

    DEFF Research Database (Denmark)

    Johansen, Lena Westphal; Brodersen, John

    2011-01-01

    INTRODUCTION: Because of shortage of personnel for the Danish mammography screening programme, the aim of this study was to investigate the attitudes of radiologists and radiographers towards a future implementation of radiographers reading screening mammograms. MATERIALS AND METHODS: Seven...... do routinely measure the performance quality, radiographers obtain sufficient reading qualifications, and skill mix improves quality. Quality related obstacles: radiologists do not routinely measure performance quality. Organization related possibilities: shortage of radiologists, positive attitudes...... of managers, and improved working relations. Organization related obstacles: shortage of radiographers and negative attitudes of managers. Professional related possibilities: positive experience with skill mix. Professional related obstacles: worries about negative consequences for the training...

  1. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images.

    Science.gov (United States)

    Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin

    2017-12-01

    Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.

  2. O conceito de "novidade" no projeto do Nuevo Cine Latinoamericano

    Directory of Open Access Journals (Sweden)

    Ignacio Del Valle Dávila

    2013-06-01

    Full Text Available Este artigo aborda o projeto de desenvolvimento cinematográfico conhecido como Nuevo Cine Latinoamericano a partir de uma análise do conceito de "novidade". Ele está centrado nas razões que levaram alguns cineastas, no final dos anos 1960, a considerar que seus filmes eram "novos". Analisa assim suas particularidades em relação aos novos cinemas europeus, com foco no viés revolucionário que adquire o termo "novo" na América Latina. Por fim, o conceito é estudado utilizando como fonte as declarações e os debates públicos dos festivais do Sodre, em Montevidéu (1958, Sestri Levante (1962 e 1963 e Viña del Mar (1967.

  3. Cine: Line excitation by infrared fluorescence in cometary atmospheres

    Science.gov (United States)

    de Val-Borro, Miguel; Cordiner, Martin A.; Milam, Stefanie N.; Charnley, Steven B.

    2017-03-01

    CINE is a Python module for calculating infrared pumping efficiencies that can be applied to the most common molecules found in cometary comae such as water, hydrogen cyanide or methanol. Excitation by solar radiation of vibrational bands followed by radiative decay to the ground vibrational state is one of the main mechanisms for molecular excitation in comets. This code calculates the effective pumping rates for rotational levels in the ground vibrational state scaled by the heliocentric distance of the comet. Line transitions are queried from the latest version of the HITRAN spectroscopic repository using the astroquery affiliated package of astropy. Molecular data are obtained from the LAMDA database. These coefficients are useful for modeling rotational emission lines observed in cometary spectra at sub-millimeter wavelengths. Combined with computational methods to solve the radiative transfer equations based, e.g., on the Monte Carlo algorithm, this model can retrieve production rates and rotational temperatures from the observed emission spectrum.

  4. On being dyslexic: Student radiographers' perspectives

    International Nuclear Information System (INIS)

    Murphy, Fred

    2011-01-01

    The purpose of this paper was to provide an insight into life as a dyslexic student radiographer, identify barriers and risks in clinical training, and develop recommendations for the support of students with dyslexia. The paucity of research into dyslexia within the radiography profession is worrying, with attention focused only on the support provided by Higher Education Institutions (HEI) or inferences drawn from the experiences of other healthcare students. The impact and significance of dyslexia for student radiographers in clinical practice has never been investigated. Results: On a self-reporting scale of clinical tasks there was little or no difference between dyslexic students and non-dyslexics. Some minor traits commonly associated with dyslexics were also reported by students with no learning disabilities and an inclusion support plan for all students was advocated. In-depth interviews of 10 student radiographers revealed six distinct themes of visualising the disability, self-protection, strengths and talents, time, the badge of disability and adjustments and support. Like other healthcare students, some radiography students reported significant difficulties and prejudices and very little structured support in the clinical environment. Despite the Special Educational Needs and Disability Act being in place for several years, the support in clinical departments fell significantly short of that provided in the universities. The dyslexic students took extra responsibility for their own learning and some had developed complex coping strategies to overcome any difficulties. Conclusion: Several inclusive recommendations were developed as a result of this study that could be used to support all students on clinical placement.

  5. El cine como discurso político: formas de discurso legitimadoras en la cinematografía el narco-cine colombiano (2007-2011)

    OpenAIRE

    Valbuena Caicedo, Lesly Vanessa

    2014-01-01

    El propósito de este trabajo de grado es identificar las claves analíticas que ofrecen el análisis del discurso y la teoría de la imagen que permitan estudiar el discurso legitimador en el narco-cine colombiano escogido. Se estudiará, analizará y definirán la de la cultura de la ilegalidad en Colombia. En este trabajo las claves analíticas definidas son aplicadas para verificar su efectividad y capacidad en la investigación que busca analizar cómo el cine hace parte del discurso político por ...

  6. Farida Benlyazid: cine feminista sobre la identidad personal

    Directory of Open Access Journals (Sweden)

    Torres Calzada, Katjia

    2012-12-01

    Full Text Available This article analyses Tangier’s director Farida Benlyazid’s personal vision of the identity conflict of the Muslim Moroccan woman (a conflict deriving from the tension between the French colonial culture and the Arab-Muslim one as presented in her opera prima Bab samá maftúh / A Door to the Sky (1988, based on a script written by herself. Within the context of Moroccan cinema, Benlyazid is a pioneer in the treatment of the Muslim woman’s role in the Moroccan patriarchal system due both to her peculiar understanding of feminism and to her multicultural upbringing, which allows her to deploy a symbolic language to universalize her films and transmit the value of rites and atavistic rituals of Morocco’s popular collective imaginary and of her own intimate imaginary.

    El presente artículo analiza la visión íntima del conflicto de identidad de la mujer marroquí musulmana –entendido como la tensión entre la cultura colonial francesa y la árabe musulmana– ofrecida por la cineasta tangerina Farida Benlyazid en su opera prima como directora y guionista, Bab samá maftúh / Une porte sur le ciel (“La puerta abierta del cielo”, 1988. Benlyazid es una pionera del cine marroquí en el tratamiento del papel de la mujer musulmana en el seno del patriarcado marroquí por su particular concepción del feminismo y por su formación multicultural, que le permite emplear un lenguaje simbólico para universalizar su cine y transmitir el valor de ritos y rituales atávicos en el imaginario colectivo popular marroquí así como en el de su imaginario íntimo.

  7. Radiographic assessment of endodontic working length

    OpenAIRE

    Osama S Alothmani; Lara T Friedlander; Nicholas P Chandler

    2013-01-01

    The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected ...

  8. Characterization Of The Advanced Radiographic Capability Front End On NIF

    International Nuclear Information System (INIS)

    Haefner, C.; Heebner, J.; Dawson, J.; Fochs, S.; Shverdin, M.; Crane, J.K.; Kanz, V.K.; Halpin, J.; Phan, H.; Sigurdsson, R.; Brewer, W.; Britten, J.; Brunton, G.; Clark, W.; Messerly, M.J.; Nissen, J.D.; Nguyen, H.; Shaw, B.; Hackel, R.; Hermann, M.; Tietbohl, G.; Siders, C.W.; Barty, C.J.

    2009-01-01

    We have characterized the Advanced Radiographic Capability injection laser system and demonstrated that it meets performance requirements for upcoming National Ignition Facility fusion experiments. Pulse compression was achieved with a scaled down replica of the meter-scale grating ARC compressor and sub-ps pulse duration was demonstrated at the Joule-level

  9. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin...

  10. Chest radiographic findings in Human Immunodeficiency Virus ...

    African Journals Online (AJOL)

    Patients had postero-anterior (PA) chest radiographs done in full inspiration, with a Roentgen 301 radiographic machine (GEC Medical) using the following factors; KVp = 65, focus-film distance = 150cm and 12 – 15mAs. A total of 308 confirmed HIV- positive patients had chest radiographic examinations. Ninety-nine ...

  11. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  12. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...... and assessing their radiographic image quality on an arbitrary scale....

  13. Radiographic imaging for Ilizarov limb lengthening in children

    International Nuclear Information System (INIS)

    Blane, C.E.; DiPietro, M.A.; Herzenberg, J.E.

    1991-01-01

    The Ilizarov method for limb lengthening is rapidly gaining popularity in North America. Use of this new technique has necessitated modifications in radiographic protocol. Initial imaging problems gained from our experience with twenty children are detailed including accurate centering for the plain films, correcting for magnification to accurately measure the distraction gap and the expected radiographic appearance of the regenerate bone. Ultrasonography has potential value in accurately measuring the distraction gap and in imaging the new bone prior to radiographic appearance. Since overly fast distraction inhibits bone formation and overly slow distraction leads to premature consolidation, ultrasound may serve a useful role in the qualitative evaluation of new bone formation in Ilizarov limb lengthening, enabling the orthopedic surgeon to tailor the distraction rate to the particular child. (orig.)

  14. Monte Carlo simulation for radiographic applications

    International Nuclear Information System (INIS)

    Tillack, G.R.; Bellon, C.

    2003-01-01

    Standard radiography simulators are based on the attenuation law complemented by built-up-factors (BUF) to describe the interaction of radiation with material. The assumption of BUF implies that scattered radiation reduces only the contrast in radiographic images. This simplification holds for a wide range of applications like weld inspection as known from practical experience. But only a detailed description of the different underlying interaction mechanisms is capable to explain effects like mottling or others that every radiographer has experienced in practice. The application of Monte Carlo models is capable to handle primary and secondary interaction mechanisms contributing to the image formation process like photon interactions (absorption, incoherent and coherent scattering including electron-binding effects, pair production) and electron interactions (electron tracing including X-Ray fluorescence and Bremsstrahlung production). It opens up possibilities like the separation of influencing factors and the understanding of the functioning of intensifying screen used in film radiography. The paper discusses the opportunities in applying the Monte Carlo method to investigate special features in radiography in terms of selected examples. (orig.) [de

  15. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  16. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  17. A Radiographic Study of Odontoma

    International Nuclear Information System (INIS)

    Lee, Kyung Ho; Choi, Karp Shik

    1998-01-01

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows ; 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  18. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  19. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  20. A radiographic study of cementoma

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, Division of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1986-11-15

    This study was undertaken to document and better define this condition to help clarify this clinical and radiographic appearances by analysis of clinical and radiographic features of cementoma. A study was made of a series of 104 cases with cementoma. This investigation of cementoma revealed the following features: 1. The female occurred in 73% of periapical cemental dysplasia and benign cementoblastoma, and 80% of cementifying fibroma. 2. 40% of periapical cemental dysplasia occurred in the fifth decades, and 73% of benign cementoblastoma during the second and third decades, while there was no age predilection in the cementifying fibroma. 3. 63% of periapical cemental dysplasia occurred in the mandibular anterior region. 91% of benign cementoblastom a and 80% of cementifying fibroma occurred in the mandibular premolar and/or molar region. 4. There were no cases complaining the associated clinical signs and subjective symptoms in the periapical cemental dysplasia, however the patient complained the pain in 36% of benign cementoblastoma and 40% of cementifying fibroma. 5. There were no cases expanding the cortical plates in the periapical cemental dysplasia, however 73% of benign cementoblastoma and all of 5 cases of cementifying fibroma showed the expansion of cortical plates. 6. Several radiographic features of the periapical cemental dysplasia were shown. a. 29% of the cases had multiple lesion. b. 53% of the cases were in mature stage. c. During the osteolytic stage, the alveolar lamina dura was lost in 89% of the cases.

  1. Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.

    Science.gov (United States)

    Moghari, Mehdi H; Barthur, Ashita; Amaral, Maria E; Geva, Tal; Powell, Andrew J

    2018-07-01

    To develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. In a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. All 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. The novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Megavoltage conebeam CT cine as final verification of treatment plan in lung stereotactic body radiotherapy.

    Science.gov (United States)

    Kudithipudi, Vijay; Gayou, Olivier; Colonias, Athanasios

    2016-06-01

    To analyse the clinical impact of megavoltage conebeam computed tomography (MV-CBCT) cine on internal target volume (ITV) coverage in lung stereotactic body radiotherapy (SBRT). One hundred and six patients received lung SBRT. All underwent 4D computed tomography simulation followed by treatment via image guided 3D conformal or intensity modulated radiation. Prior to SBRT, all patients underwent MV-CBCT cine, in which raw projections are displayed as beam's-eye-view fluoroscopic series with the planning target volume (PTV) projected onto each image, enabling verification of tumour motion relative to the PTV and assessment of adequacy of treatment margin. Megavoltage conebeam computed tomography cine was completed 1-2 days prior to SBRT. Four patients (3.8%) had insufficient ITV coverage inferiorly at cine review. All four plans were changed by adding 5 mm on the PTV margin inferiorly. The mean change in PTV volumes was 3.9 cubic centimetres (cc) (range 1.85-6.32 cc). Repeat cine was performed after plan modification to ensure adequate PTV coverage in the modified plans. PTV margin was adequate in the majority of patients with this technique. MV-CBCT cine did show insufficient coverage in a small subset of patients. Insufficient PTV margins may be a function of 4D CT simulation inadequacies or deficiencies in visualizing the ITV inferior border in the full-inhale phase. MV-CBCT cine is a valuable tool for final verification of PTV margins. © 2016 The Royal Australian and New Zealand College of Radiologists.

  3. Strain analysis in CRT candidates using the novel segment length in cine (SLICE) post-processing technique on standard CMR cine images

    NARCIS (Netherlands)

    Zweerink, A.; Allaart, C.P.; Kuijer, J.P.A.; Wu, L.; Beek, A.M.; Ven, P.M. van de; Meine, M.; Croisille, P.; Clarysse, P.; Rossum, A.C. van; Nijveldt, R.

    2017-01-01

    OBJECTIVES: Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive

  4. Tras los pasos del Cine en Ecuador: la producción nacional y políticas de apoyo

    Directory of Open Access Journals (Sweden)

    Violeta Yalilé Loaiza Ruiz

    2015-12-01

    Full Text Available Con el presente trabajo reflexionamos sobre el estado actual del cine ecuatoriano, la incidencia que en él tiene la actual Ley del Cine y la participación del Consejo Nacional del Cine en su financiación. Partimos de una historia del cine, desde sus comienzos en el último cuarto del siglo XIX, con las primeras filmaciones de Theodor Wolf, hasta la actualidad. Analizaremos las causas de las preferencias de los espectadores, la dicotomía entre cine documental y ficcional, a través de las más importantes películas realizadas en el país y su incidencia internacional. Para ello hemos utilizado la entrevista a tres de sus más importantes protagonistas/actores, Wilma Granda, Alex Schlenker y Santiago Carpio, para conocer su opinión del cine en Ecuador. El cine ecuatoriano sigue evolucionando pese a los obstáculos políticos y económicos que existentes y la fuerte competencia del cine extranjero, fundamentalmente de los Estados Unidos.

  5. Right ventricular volume and mass determined by cine magnetic resonance imaging in HIV patients with possible right ventricular dysfunction

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette; Gerstoft, Jan

    2006-01-01

    Impaired right ventricular (RV) function has been reported to occur in patients with HIV when studied by echocardiography. However, for accurate evaluation of RV function and morphology, first-pass radionuclide ventriculography (RNV) and cine magnetic resonance imaging (cine-MRI) are methods...

  6. El nuevo cine de espectáculo como estrategia comercial. Un análisis de las tendencias del consumo de cine en salas

    Directory of Open Access Journals (Sweden)

    Marina Moguillansky

    Full Text Available Resumen En la Argentina, se acaban de cumplir diez años de la introducción de dos políticas de regulación de la exhibición que buscaron proteger al cine nacional: la cuota de pantalla y la media de continuidad. En este trabajo, proponemos un análisis de la evolución del consumo de cine en salas, a la luz de la nueva regulación y de una serie de cambios que se produjeron en el período. El análisis se basa en datos cuantitativos y cualitativos de fuentes complementarias que nos permiten reconstruir las tendencias de la asistencia a salas, las elecciones de los espectadores y sus motivaciones. Según estos datos, el cine se escinde en dos grandes territorios: por un lado, las películas “para ver en el cine”, y por otro lado, las películas “para ver en casa”. La recaudación en salas se sostiene principalmente en la buena performance de las películas infantiles, las secuelas, el 3D y las películas de alto impacto visual. El cine argentino se consume sobre todo por televisión y en el hogar, con la excepción de un conjunto limitado de películas y de un sector especial del público que elige explícitamente apoyar al cine argentino concurriendo a las salas.

  7. Chest wall invasion by bronchogenic carcinoma. Evaluation with Cine-MRI

    International Nuclear Information System (INIS)

    Nawano, Shigeru; Murakami, Kohji; Ohnuma, Hiroshi; Iwata, Ryoko; Hayashi, Takayuki; Moriyama, Noriyuki; Nishiwaki, Yutaka; Nagai, Kanji

    1996-01-01

    With the view of examining possible chest wall invasion of bronchogenic carcinoma, Cine-MRI was performed on 22 such cases. These cases were suspected of having above chest wall invasion by CT and their histopathological findings were obtained in surgery. The judgment of the chest wall invasion by Cine-CT was made such that non-moving up and down of the tumor with respiration involves its invasion, moving of the tumor without any up-and-down movement suspects its invasion and moving up and down of the tumor with respiration involves no invasion. The chest wall invasion was observed in 5 of 7 cases of invasion judged by Cine-MRI. For 2 false-positive cases, the histopathological findings presumed that tumor cells disappeared from the chest wall invaded region as the result of preoperative chemotherapy. The above invasion was observed in 1 of 4 cases suspected of possible invasion. Correct diagnosis was formed of 11 cases judged invasion-free by Cine-MRI. The above results suggested Cine-MRI to be useful for diagnosis of chest wall invasion of bronchogenic carcinoma. (author)

  8. Accelerated cardiac cine MRI using locally low rank and finite difference constraints.

    Science.gov (United States)

    Miao, Xin; Lingala, Sajan Goud; Guo, Yi; Jao, Terrence; Usman, Muhammad; Prieto, Claudia; Nayak, Krishna S

    2016-07-01

    To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. At 10 to 60 spokes/frame, LLR+FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR+FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2×2mm(2) and 40ms. Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Feasibility of vocal fold abduction and adduction assessment using cine-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Baki, Marina Mat [National University of Malaysia, Faculty of Medicine, Kuala Lumpur (Malaysia); Menys, Alex; Morley, Simon; Beale, Timothy [University College London, Centre for Medical Imaging, London (United Kingdom); Atkinson, David; Punwani, Shonit [University College London, Centre for Medical Imaging, London (United Kingdom); Royal National Throat Nose Ear Hospital, University College London Hospital NHS Trust, London (United Kingdom); Bassett, Paul [University College London, London (United Kingdom); Sandhu, Guri [Charing Cross Hospital, Imperial College Healthcare NHS Trust, London (United Kingdom); Naduvilethil, Georgekutty; Stevenson, Nicola [Royal National Throat Nose Ear Hospital, University College London Hospital NHS Trust, London (United Kingdom); Birchall, Martin A. [Royal National Throat Nose Ear Hospital, University College London Hospital NHS Trust, London (United Kingdom); University of California, Davis, Department of Otolaryngology, Davis, CA (United States); University College London, Ear Institute, London (United Kingdom)

    2017-02-15

    Determine feasibility of vocal fold (VF) abduction and adduction assessment by cine magnetic resonance imaging (cine-MRI) Cine-MRI of the VF was performed on five healthy and nine unilateral VF paralysis (UVFP) participants using an axial gradient echo acquisition with temporal resolution of 0.7 s. VFs were continuously imaged with cine-MRI during a 10-s period of quiet respiration and phonation. Scanning was repeated twice within an individual session and then once again at a 1-week interval. Asymmetry of VF position during phonation (VF phonation asymmetry, VFPa) and respiration (VF respiration asymmetry, VFRa) was determined. Percentage reduction in total glottal area between respiration and phonation (VF abduction potential, VFAP) was derived to measure overall mobility. An un-paired t-test was used to compare differences between groups. Intra-session, inter-session and inter-reader repeatability of the quantitative metrics was evaluated using intraclass correlation coefficient (ICC). VF position asymmetry (VFPa and VFRa) was greater (p=0.012; p=0.001) and overall mobility (VFAP) was lower (p=0.008) in UVFP patients compared with healthy participants. ICC of repeatability of all metrics was good, ranged from 0.82 to 0.95 except for the inter-session VFPa (0.44). Cine-MRI is feasible for assessing VF abduction and adduction. Derived quantitative metrics have good repeatability. (orig.)

  10. Feasibility of vocal fold abduction and adduction assessment using cine-MRI

    International Nuclear Information System (INIS)

    Baki, Marina Mat; Menys, Alex; Morley, Simon; Beale, Timothy; Atkinson, David; Punwani, Shonit; Bassett, Paul; Sandhu, Guri; Naduvilethil, Georgekutty; Stevenson, Nicola; Birchall, Martin A.

    2017-01-01

    Determine feasibility of vocal fold (VF) abduction and adduction assessment by cine magnetic resonance imaging (cine-MRI) Cine-MRI of the VF was performed on five healthy and nine unilateral VF paralysis (UVFP) participants using an axial gradient echo acquisition with temporal resolution of 0.7 s. VFs were continuously imaged with cine-MRI during a 10-s period of quiet respiration and phonation. Scanning was repeated twice within an individual session and then once again at a 1-week interval. Asymmetry of VF position during phonation (VF phonation asymmetry, VFPa) and respiration (VF respiration asymmetry, VFRa) was determined. Percentage reduction in total glottal area between respiration and phonation (VF abduction potential, VFAP) was derived to measure overall mobility. An un-paired t-test was used to compare differences between groups. Intra-session, inter-session and inter-reader repeatability of the quantitative metrics was evaluated using intraclass correlation coefficient (ICC). VF position asymmetry (VFPa and VFRa) was greater (p=0.012; p=0.001) and overall mobility (VFAP) was lower (p=0.008) in UVFP patients compared with healthy participants. ICC of repeatability of all metrics was good, ranged from 0.82 to 0.95 except for the inter-session VFPa (0.44). Cine-MRI is feasible for assessing VF abduction and adduction. Derived quantitative metrics have good repeatability. (orig.)

  11. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

    Science.gov (United States)

    Motaal, Abdallah G; Coolen, Bram F; Abdurrachim, Desiree; Castro, Rui M; Prompers, Jeanine J; Florack, Luc M J; Nicolay, Klaas; Strijkers, Gustav J

    2013-04-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exploit the stochastic nature of the retrospective triggering acquisition scheme to produce an undersampled and random k-t space filling that allows for compressed sensing reconstruction and acceleration. As a standard, a self-gated FLASH sequence with a total acquisition time of 10 min was used to produce single-slice Cine movies of seven mouse hearts with 90 frames per cardiac cycle. Two times (2×) and three times (3×) k-t space undersampled Cine movies were produced from 2.5- and 1.5-min data acquisitions, respectively. The accelerated 90-frame Cine movies of mouse hearts were successfully reconstructed with a compressed sensing algorithm. The movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters, i.e. end-systolic and end-diastolic lumen surface areas and early-to-late filling rate ratio as a parameter to evaluate diastolic function, derived from the standard and accelerated Cine movies, were nearly identical. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Escala propuesta para medir la calidad del servicio de los cines

    Directory of Open Access Journals (Sweden)

    Eduardo Torres Moraga1

    2010-04-01

    Full Text Available En la actualidad, existe un alto nivel de competencia entre las diferentes cadenas de cines que se encuentran en Chile. En este escenario, el éxito está determinado en gran parte por los servicios que estas ofrecen a sus clientes. Si bien previamente se han desarrollado escalas para medir la calidad del servicio percibida en diversos sectores, por sus características, es necesario construir una escala específica que pueda ser aplicada a los cines. Los resultados obtenidos por medio de este estudio muestran que la calidad del servicio de los cines percibida por los consumidores es un constructor multidimensional que difiere en gran parte de las escalas estándar propuestas anteriormente, y que además se compone de la confiabilidad, la atención personal, la accesibilidad, los tangibles del cine y los tangibles de la sala de proyección de la película. Estos resultados entregan a los directivos de marketing de los cines una importante herramienta que les permitirá medir y gestionar la calidad del servicio.

  13. Comparison of standard, prone and cine MRI in the evaluation of tethered cord

    International Nuclear Information System (INIS)

    Singh, Sukhjinder; Kline-Fath, Beth; Racadio, Judy M.; Bierbrauer, Karin; Salisbury, Shelia; Macaluso, Maurizio; Jackson, Elizabeth C.; Egelhoff, John C.

    2012-01-01

    Tethered cord syndrome (TCS) is defined by abnormal traction on the spinal cord that confines its movement. Surgical cord release usually stops neurological deterioration; therefore, early and accurate neuroradiological diagnosis is important. Supine MRI is the imaging modality of choice, but prone MRI and cine MRI can demonstrate cord movement. We compared the diagnostic accuracies of standard MRI, prone MRI and cine MRI in patients with clinical suspicion of TCS and evaluated inter-reader reliability for MR imaging. Children who underwent MRI for suspicion of TCS were retrospectively identified. Supine, prone and cine MRI studies were re-read by two pediatric neuroradiologists. Conus level, filum appearance and cord movement were documented. Thirteen of 49 children had tethered cord documented at surgery. Conus level had the highest diagnostic accuracy (sensitivity 69-77%, specificity 94%, positive predictive value 82-83%, negative predictive value 89-92%, correct diagnosis 88-90%) and highest between-reader concordance (98%). Prone and cine MRI did not add to the accuracy of the supine imaging. Conus level provides the highest diagnostic accuracy and inter-reader reliability in TCS. Until a larger series is evaluated, it remains questionable whether prone or cine MRI provides enough additional diagnostic information to warrant routine use. (orig.)

  14. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  15. Teatro-cine Eileen Norris - California (EE.UU.

    Directory of Open Access Journals (Sweden)

    Martin, Albert C.

    1978-10-01

    Full Text Available This building forms a part of the substructure of the Department of the Cinema of the University of Southern California. Among its various functions, it includes the practical teaching of cinematography. It consists of a ground floor for accesses and auditorium, with a surface measuring 1,950 m2, and a basement of the same extension, designed for a film library and film deposit. The auditorium has a capacity for 350 spectators and is equipped with a screen adaptable to the projection of 16, 35 and 70 mm films, as well as equipment for the projection of slides and video tapes. It can also be conditioned as a lecture hall, for which purpose, complete sets of equipment fort simultaneous translation have been installed. On the outside, the architecture presents a neoclassical design, based on a portico of four large white cement columns, which combines with Marble exteriors on the walls.

    Este edificio forma parte de la infraestructura del Departamento de Cine de la Universidad de California del Sur. Entre sus diversas funciones comprende la enseñanza práctica de la cinematografía. Consta de una planta baja destinada a accesos y auditorio, de 1.950 m2 de superficie, y un sótano, de la misma extensión, destinado a biblioteca de cine y a depósito de películas. El auditorio tiene capacidad para 350 espectadores y cuenta con una pantalla adaptable a la proyección de films de 16, 35 y 70 mm, así como con equipos para la proyección de diapositivas y cintas de video-tapes. Puede acondicionarse, igualmente, como sala de conferencias, para lo cual se han instalado unos completos equipos de traducción simultánea. Exteriormente, la arquitectura presenta un diseño neoclásico, basado en un pórtico de cuatro grandes columnas de cemento blanco que combina con revestimientos de mármol y en los paramentos verticales.

  16. Mentoring assistant practitioners - The radiographer's perspective

    International Nuclear Information System (INIS)

    Colthart, Iain; McBride, Margot; Murray, Maria

    2010-01-01

    Purpose: The aim of this study was to evaluate the experiences of diagnostic and therapeutic radiographers as they mentored trainee assistant practitioners undertaking an educational programme. The evaluation study describes the challenges and benefits the radiographers experienced as mentors as well as giving their insights into the introduction of assistant practitioners in their departments. Method: The mentors' opinions were sought by a questionnaire which formed part of the evaluation of the respective diagnostic imaging and therapeutic educational programmes run by two colleges. Results: The response rate was 54% (22/41). Mentors described personal and professional benefits for themselves from undertaking this role. Although mentoring had provided a number of challenges including an increase in workload, the experience had also enhanced their teaching and mentoring skills and contributed to their Continuing Professional Development (CPD). Whilst the role was more time consuming than initially expected this had not impacted generally on their ability to undertake CPD or deliver patient care. In relation to the wider impact of the programmes some negative impact was reported on the speed of service delivery but not on the quality of practice. Mentors felt that the programmes had a positive effect on teamworking and had been beneficial for patient care. Some difficulties were noted in balancing the mentoring of trainee assistant practitioners and radiography undergraduates. Conclusion: The mentors strongly endorsed the educational programmes and their roles and responsibilities in their delivery. Protected time to carry out mentoring duties and establishing good communication with the colleges providing the theoretical teaching were identified as means of further improving the mentoring process.

  17. The prevalence of radiographic hip abnormalities in elite soccer players.

    Science.gov (United States)

    Gerhardt, Michael B; Romero, Alex A; Silvers, Holly Jacinda; Harris, David J; Watanabe, Diane; Mandelbaum, Bert R

    2012-03-01

    Hip injuries, both intra- and extra-articular, are becoming a more commonly recognized, diagnosed, and treated injury in athletes of all competitive levels. Our goal is to establish a previously undefined value in this athletic population--the prevalence of radiographic hip abnormalities in elite soccer athletes. To provide a foundation for the future body of literature regarding hip pathologic abnormalities and "at-risk" hips in athletes of all ages and levels of participation. Descriptive epidemiology study. We retrospectively reviewed the anteroposterior pelvis and frog-leg lateral radiographs of 95 elite male and female soccer players to determine the prevalence of hip abnormalities. Athletes with a history of hip or groin injuries were included. Multiple radiographic parameters were used to assess the presence of cam and pincer-type femoroacetabular impingement. Measurements were conducted by a blinded, sports medicine fellowship-trained orthopaedic surgeon with experience in treating hip disorders. In total, 72% (54/75) of male and 50% (10/20) of female players demonstrated some evidence of radiographic hip abnormality. Cam lesions were present in 68% (51/75) of men (76.5% [39/51] bilateral involvement) and 50% (10/20) of women (90% [9/10] bilateral involvement). Pincer lesions were present in 26.7% (20/75) of men and 10% (2/20) of women. The average male alpha angle overall was 65.6°. Cam-positive hips averaged 70.7°. The average female alpha angle overall was 52.9°, with cam-positive hips averaging 60.8°. The prevalence of radiographic hip abnormalities in elite soccer athletes is considerable, particularly in young male athletes. The establishment of the prevalence of these findings represents the first step in identifying the relationship between radiographic abnormalities and injuries of the hip and groin in athletes.

  18. The future for the radiographer

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    that it is not the patient who must comply with technology, but the other way around. My point is that if reporting radiographers merely focuses on technology then they leave behind the very core of radiography, namely radiography as a caring practice, which would leave care in the hands of less educated personnel. So I....... We believe that it is time that we take responsibility for this important part of radiography and systematically teaching it in the context where it unfolds instead of insinuating that care is learned best elsewhere. I believe and hope that especially the Nordic countries could learn from each other...

  19. Paired inspiratory/expiratory spiral CT and continuous respiration cine CT in the diagnosis of tracheal instability

    International Nuclear Information System (INIS)

    Heussel, C.P.; Schreiber, W.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2001-01-01

    In tracheo- and bronchomalacia, localisation and determination of collapse is necessary for planning of surgical procedure. We compared inspiratory and expiratory spiral CT, cine CT, bronchoscopy, exemplary cine MR, and evaluated the clinical relevance. Twenty-nine patients (2 follow-ups; mean age 61 years, age range 27-85 years) with suspected or verified tracheal stenosis or collapse (post-tracheotomy: n=17; neoplasm: n=5; other: n=7) underwent paired breath-hold inspiratory and expiratory spiral CT. Forty-five additional cine CT were performed at 1-4 levels (mean 1.5) during continuous respiration (increment 100 ms) to clarify respiratory collapse. The tracheal cross-sectional diameters of both techniques were calculated. Comparison with bronchoscopy, follow-up, and influence upon therapy were evaluated retrospectively. Exemplary comparison with cine MR (8 frames/s) was done in 3 cases. In addition to bronchoscopy, further information concerning localisation, extent, collapse, stability of the tracheal wall, distal portions of the stenosis and extraluminal compressions were obtained. A significantly higher degree and more pathological collapses (>50%) were seen using cine CT (38%) compared with paired spiral CT (13%; degree: p<0.0001; number: p<0.001). The findings changed the further therapeutic procedure in 16 of 29 patients. Further stenoses were excluded and bronchoscopy was verified in another 13 of 29. Temporal resolution of cine CT and cine MR is sufficient; however, spatial resolution of cine MR is inferior. Paired inspiratory and expiratory spiral CT localises tracheal stenoses and demonstrates relevant extraluminal compression. Significantly improved evaluation of respiratory collapse and further information of localised tracheal instability is obtained by cine CT. Cine MR promises more functional information especially due to free choice of imaging plane. (orig.)

  20. El Gauchito Gil neo expresionista del cine digital argentino

    Directory of Open Access Journals (Sweden)

    Cleopatra Barrios Cristaldo

    2013-01-01

    Full Text Available [es] Este trabajo se aproxima a las representaciones de la marginalidad y la religiosidad popular argentina en la película “Gauchito Gil, la sangre inocente” (2006, dirigido por Ricardo Becher y Tomás Larrinaga. También examina la modalidad de narrativa adoptada por los autores como un acto intelectual, subjetivo y revolucionario que reacciona contra el realismo del cine argentino a través de formas signadas por un tratamiento especial de la imagen del video en la postproducción digita. [en] This paper approaches to the representations of the marginality and the popular Argentine religiousness in the movie “Gauchito Gil, the innocent blood” (2006, directed by Ricardo Becher and Tomás Larrinaga. Also it examines the narrative modality adopted by the authors as an intellectual, subjective and revolutionary act that reacts against the realism of the Argentine cinema in ways that are marked by a special treatment of the image of the video in the digital post-production

  1. Cine MR imaging of uterine peristalsis in patients with endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Kido, Aki; Togashi, Kaori; Koyama, Takashi; Fujimoto, Ryota [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto (Japan); Nishino, Mizuki [Beth Israel Deaconess Medical Center, Department of Radiology, Kyoto (Japan); Miyake, Kanae; Hayakawa, Katsumi [Kyoto City Hospital, Department of Radiology, Kyoto (Japan); Iwasaku, Kazuhiro [Kyoto City Hospital, Department of Obstetrics and Gynecology, Kyoto (Japan); Fujii, Shingo [Kyoto University, Department of Gynecology and Obstetrics, Kyoto (Japan)

    2007-07-15

    Endometriosis is one of the most important causes of infertility; however the precise mechanism by which it affects female fertility is unclear. The objective of this study was to study the functional aspects of the uterus by evaluating uterine contractility in patients with endometrial cysts of the ovary. The study population was recruited from two institutes and consisted of 26 women (periovulatory (10), luteal (13), and menstrual phase (3); age range: 19-51 years) with untreated endometriosis; the control group consisted of 12 healthy women (age range: 22-41 years). Cine MR imaging obtained by a 1.5T magnet was visually evaluated at 12 x faster than real speed, focusing on the presence of uterine peristalsis, the direction and frequency of peristalsis, and the presence of sustained uterine contractions. Uterine peristalsis was identifiable in 3/10, 3/13, and 3/3 of the endometriosis patients in each menstrual cycle, respectively, and in 11/12, 3/12, and 5/12 of their control subjects. Peristaltic detection rate and frequency were significantly less for the endometriosis group than for the controls in the periovulatory phase only (p<0.05). Sustained contractions were recognized in 19/36 control subjects and in 13/26 endometriosis patients, but the difference was not significant. Uterine peristalsis appears to be suppressed during the periovulatory phase in patients with endometriosis, which may have an adverse effect on sperm transport. (orig.)

  2. Cine MR imaging of uterine peristalsis in patients with endometriosis

    International Nuclear Information System (INIS)

    Kido, Aki; Togashi, Kaori; Koyama, Takashi; Fujimoto, Ryota; Nishino, Mizuki; Miyake, Kanae; Hayakawa, Katsumi; Iwasaku, Kazuhiro; Fujii, Shingo

    2007-01-01

    Endometriosis is one of the most important causes of infertility; however the precise mechanism by which it affects female fertility is unclear. The objective of this study was to study the functional aspects of the uterus by evaluating uterine contractility in patients with endometrial cysts of the ovary. The study population was recruited from two institutes and consisted of 26 women (periovulatory (10), luteal (13), and menstrual phase (3); age range: 19-51 years) with untreated endometriosis; the control group consisted of 12 healthy women (age range: 22-41 years). Cine MR imaging obtained by a 1.5T magnet was visually evaluated at 12 x faster than real speed, focusing on the presence of uterine peristalsis, the direction and frequency of peristalsis, and the presence of sustained uterine contractions. Uterine peristalsis was identifiable in 3/10, 3/13, and 3/3 of the endometriosis patients in each menstrual cycle, respectively, and in 11/12, 3/12, and 5/12 of their control subjects. Peristaltic detection rate and frequency were significantly less for the endometriosis group than for the controls in the periovulatory phase only (p<0.05). Sustained contractions were recognized in 19/36 control subjects and in 13/26 endometriosis patients, but the difference was not significant. Uterine peristalsis appears to be suppressed during the periovulatory phase in patients with endometriosis, which may have an adverse effect on sperm transport. (orig.)

  3. [Visualization of laryngopharynx during swallowing of negative contrast media (air) with cine mode 64-row MDCT].

    Science.gov (United States)

    Fudeya, Taku; Otake, Shoichiro; Watabe, Hirotaka; Mitsuoka, Takashi; Yoshikawa, Akitoshi

    2010-05-20

    Video fluoroscopic examination of swallowing generally needs a contrast media such as a barium sulfate. Since the examination is usually performed in patients with dysphasia, there is a risk of aspiration. We tried to visualize the laryngopharynx during swallowing of negative contrast media (air) with 64-row multi-detector computed tomography (64-MDCT). Cine mode 64-MDCT was performed to visualize the laryngopharynx in 4 healthy volunteers during swallowing of negative contrast media (air). The data were converted to three-dimensional (3D) images of 2 conditions (air and bone) and sagittal images of the soft tissue condition at a workstation. These images were sent to a personal computer and modeled to 3D cine images with Digital Imaging and Communication in Medicine (DICOM) Viewer and Quick Time Player. 3D cine images demonstrated movements of the epiglottis, vallecula, piriform sinus, tongue, pharyngeal wall, hyoid bone and thyroid cartilage.

  4. El cine mexicano de la edad de oro y su impacto internacional

    Directory of Open Access Journals (Sweden)

    Maricruz Castro-Ricalde

    2014-06-01

    Full Text Available A partir de una investigación documental en publicaciones periódicas de Argentina, Colombia, Cuba, Chile, Estados Unidos, Honduras, México, Nicaragua y Venezuela, este artículo demuestra el interés que el cine mexicano producido entre 1936 y 1956 provocó en los espectadores de Hispanoamérica y Estados Unidos, al igual que la presencia de actores, cineastas, temas y personajes de otros países hispanohablantes en la industria cinematográfica mexicana durante la denominada edad de oro del cine mexicano. Se constató la influencia de este cine en la conformación de la identidad cultural de los mexicanos y su proyección internacional.

  5. Filmografía y bibliografía del cine negro americano (1930-1960

    Directory of Open Access Journals (Sweden)

    Dr. José Luis Sánchez Noriega

    1999-01-01

    Full Text Available La actualidad del cine negro queda patente con el éxito de crítica y de público de obras recientes como Casino (Martin Scorsese, 1995, La brigada del sombrero (Lee Tamahori, 1996, Al caer el sol (Robert Benton, 1996 o Donnie Brasco (Mike Newell, 1996. Hace unos meses han aparecido dos libros que se ocupan de este género y ofrecen una selección de un centenar de películas: El cine negro en 100 películas de Antonio Santamarina (Alianza, Madrid, 1999 y Obras maestras del cine negro (Mensajero, Bilbao, 1998, de quien firma estas líneas.

  6. El cine mexicano de la edad de oro y su impacto internacional

    Directory of Open Access Journals (Sweden)

    Maricruz Castro-Ricalde

    2014-01-01

    Full Text Available A partir de una investigación documental en publicaciones periódicas de Argentina, Colombia, Cuba, Chile, Estados Unidos, Honduras, México, Nicaragua y Venezuela, este artículo demuestra el interés que el cine mexicano producido entre 1936 y 1956 provocó en los espectadores de Hispanoamérica y Estados Unidos, al igual que la presencia de actores, cineastas, temas y personajes de otros países hispanohablantes en la industria cinematográfica mexicana durante la denominada edad de oro del cine mexicano. Se constató la influencia de este cine en la conformación de la identidad cultural de los mexicanos y su proyección internacional.

  7. Cine MR evaluation of the inferior vena cava in patients with Simon Nitinol filters

    International Nuclear Information System (INIS)

    Steinberg, F.L.; Denham, J.S.; Geller, S.C.; Manickas, A.P.; Athanasoulis, C.A.; Cohn, M.J.; Taafe, J.L.; Waltman, A.C.

    1988-01-01

    This study evaluated the ability of cine MR imaging to detect thrombus in the inferior vena cava (IVC) of seven patients after percutaneous implantation of Simon-Nitinol filters. Cine MR imagine was performed at 0.6 T. Sixteen phases of the cardiac cycle were obtained in sagittal or coronal projection with echo time equal to 15 msec, repetition time equal to 40 msec, and flip angle of 40 0 . The section thickness was 7.5 mm. Blood flow in the IVC had high signal intensity that varied with the cardiac cycle. Thrombus had a range of signal intensities, but there was no variation of signal intensity during the cardiac cycle. The Simon-Nitinol filter caused no detectable image degradation. Cine MR imaging had the ability to detect thrombosis of the IVC below the filter and thrombus above the filter, and localize the position of the filter

  8. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  9. Overcoming pitfalls in the diagnosis of aortic dissection with phase-contrast cine MR imaging

    International Nuclear Information System (INIS)

    Herfkens, R.J.; Trefelner, E.C.; Jeffrey, R.B.; Pelc, N.J.; Steiner, R.M.; Francis, I.R.

    1991-01-01

    This paper evaluates whether phase contrast cine MR imaging improves the diagnostic accuracy in aortic dissection. Fifty-five MR examinations in 49 patients were analyzed. Gated coronal and axial spin-echo (SE) images and axial velocity encoded cine images were collected through the thoracic aorta. Blinded interpretations were obtained by first evaluating SE images, then SE and cine (magnitude) images, and finally with the addition of the velocity data for whether there was increase or decreased diagnostic confidence of aortic dissection. Comparisons were made with CT, angiography, and follow-up (including surgery). Fisher discriminant analysis showed that a statistically significant improvement in diagnostic accuracy was made by the addition of the velocity data in cases where a definite diagnosis of aortic dissection could not be made from the SE images alone

  10. Analysis of flow dynamics of main pulmonary artery by cine phase contrast MR angiography

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio

    1996-01-01

    Nineteen studies of cine phase contrast MR angiography (PCMRA) of main pulmonary artery (MPA) entered the study. Cine PCMRA was obtained by a 1.5T MR imager with a gradient echo sequence coupled with velocity encoding bipolar pulses. Retrospective EKG gating was used. Mean velocity, maximum velocity, and maximum flow rate of MPA were 6.2 to 28 cm/s (mean/SD 13/5.1, n=18), 61 to 148 cm/s (mean/SD 102/30, n=13), and 12,561 to 30,113 ml/min (mean/SD 18,730/5,464, n=18), respectively. Retrograde flow in the MPA was noted to begin at late-to mid-systole. Retrograde flow occurred first in the posterior part (15/19) or occurred from periphery (4/19). Thus hemodynamic parameters and velocity maps of MPA can be obtained by cine PCMRA. (author)

  11. Aproximaciones a la historia y a las corrientes del Cine Documental Peruano, 1910-1990

    OpenAIRE

    Guevara Flores, Ernesto

    2016-01-01

    Este estudio es la continuación temática y lógica de la Tesis de investigación con la que obtuvimos el título de Licenciado en Comunicación Social en la UNMSM, donde hicimos un recorrido por el cine documental del mundo. Al reunir material de información teórica había descubierto que la bibliografía y hemerografía sobre el cine documental eran escasas; y los filmes de éste género, inaccesibles. Optamos aquella vez por referirnos al cine documental mundial, al comprobar que el tema se enriquec...

  12. El cine de ciencia ficción como máquina del tiempo

    OpenAIRE

    Francescutti, Luis Pablo

    1997-01-01

    Análisis de las películas de ciencia ficción desde la perspectiva de la sociología del tiempo, y en especial del futuro. El cine, auténtica máquina de remontar los tiempos visualmente, actualizó esta potencialidad con el cine histórico en una primera fase, y con el cine de ciencia ficción en un momento posterior. Este género se especializó en explorar el continuo temporal mediante saltos hacia adelante o hacia atrás en el marco de una historia conjetural (qué hubiera sucedido si...) Cie...

  13. Algebraic Reconstruction Technique (ART) for parallel imaging reconstruction of undersampled radial data: Application to cardiac cine

    Science.gov (United States)

    Li, Shu; Chan, Cheong; Stockmann, Jason P.; Tagare, Hemant; Adluru, Ganesh; Tam, Leo K.; Galiana, Gigi; Constable, R. Todd; Kozerke, Sebastian; Peters, Dana C.

    2014-01-01

    Purpose To investigate algebraic reconstruction technique (ART) for parallel imaging reconstruction of radial data, applied to accelerated cardiac cine. Methods A GPU-accelerated ART reconstruction was implemented and applied to simulations, point spread functions (PSF) and in twelve subjects imaged with radial cardiac cine acquisitions. Cine images were reconstructed with radial ART at multiple undersampling levels (192 Nr x Np = 96 to 16). Images were qualitatively and quantitatively analyzed for sharpness and artifacts, and compared to filtered back-projection (FBP), and conjugate gradient SENSE (CG SENSE). Results Radial ART provided reduced artifacts and mainly preserved spatial resolution, for both simulations and in vivo data. Artifacts were qualitatively and quantitatively less with ART than FBP using 48, 32, and 24 Np, although FBP provided quantitatively sharper images at undersampling levels of 48-24 Np (all pparallel radial MR imaging, providing reduced artifacts while mainly maintaining sharpness compared to FBP, as shown by its first application in cardiac studies. PMID:24753213

  14. Alveolar cleft bone grafts: results and imprecisions of the dental radiograph.

    Science.gov (United States)

    Lee, C; Crepeau, R J; Williams, H B; Schwartz, S

    1995-12-01

    Alveolar cleft bone grafts customarily have been evaluated by one-dimensional dental radiographic measurements. Based on the dental radiograph, remarkable successes with just a single bone graft have been reported in the literature. At the Montreal Children's Hospital, the experience with 101 alveolar bone grafts in 62 cleft lip and palate patients was retrospectively reviewed to determine (1) the precision of dental radiographs at evaluating the clinical outcome, (2) the effect of dental maturation on alveolar bone grafts, and (3) the effect of augmentation bone grafts. The dental radiograph significantly overestimated the number of clefts that could be managed orthodontically (p orthodontic closure of the dental gap. Bone grafts performed during the preeruptive canine dentition yielded significantly better results (p < 0.05, chi-squared test). With each subsequent augmentation bone-graft procedure performed, there existed a trend toward improved dental arch stability and radiographic and clinical outcomes.

  15. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  16. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  17. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  18. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  19. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  20. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  1. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  2. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  3. Early radiographic changes in radiation bone injury

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, M.; Tanimoto, K.; Wada, T.

    1986-06-01

    A chronologic series of periapical radiographs was evaluated for the purpose of detecting damage to bone and tooth-supporting tissues in a patient receiving radiation therapy for a basal cell carcinoma of the mandibular gingiva. Widening of the periodontal space was one of the early radiographic changes observed. It is suggested, from the sequence of radiographic changes, that radiation-induced changed in the circulatory system of the bone might be primarily responsible for the resulting changes.

  4. Early radiographic changes in radiation bone injury

    International Nuclear Information System (INIS)

    Fujita, M.; Tanimoto, K.; Wada, T.

    1986-01-01

    A chronologic series of periapical radiographs was evaluated for the purpose of detecting damage to bone and tooth-supporting tissues in a patient receiving radiation therapy for a basal cell carcinoma of the mandibular gingiva. Widening of the periodontal space was one of the early radiographic changes observed. It is suggested, from the sequence of radiographic changes, that radiation-induced changed in the circulatory system of the bone might be primarily responsible for the resulting changes

  5. Value of Cine-MRI sequences before and after injection in the diagnosis of acute myocarditis.

    Science.gov (United States)

    Zidi, Asma; Zairi, Ihsen; Mzoughi, Khadija; Zakhama, Lilia; Kamoun, Ikram; Ben Halima, Afef; Ridene, Imen

    2016-11-01

    Cardiovascular magnetic resonance (CMR) has become the examination of choice in case of suspicion of acute myocarditis. Late gadolinium enhancement (LGE) imaging is very important to establish this diagnosis. Cine MRI sequences are useful for the study of the myocardial contractility.   The purpose is to estimate the value of cine MRI sequences before and after injection for the diagnosis of acute myocarditis compared with late gadolinium enhanced sequences. We prospectively included 40 patients having a high suspicion of acute myocarditis and examined using a 1.5 Tesla CMR. Cine MRI sequences before and after injection were performed. The protocol also include  T2-weighted  short- tau-inversion-recovery (STIR T2) fast spin echo MRI and LGE imaging eight minutes after injection with visual adjustment of inversion time. Delayed enhancement was found among 23 patients. Fifteen patients (65 %) presented a spontaneous hyper signal detected visually on Cine MRI sequences before injection and 11 patients (48 %) on STIR T2. The hyper signal on Cine MRI sequences after injection of gadolinium was the same topography that the late raising at 23 patients. In addition, we highlighted a significant difference between this hyper signal before injection and the left ventricle ejection fraction (p=0.022) as well as with the telesystolic volume of the left ventricle (LV) indexed by the body mass (p=0.039). Our study suggests that Cine MRI sequences after injection are of equal performance in the diagnosis of acute myocarditis as the LGE sequences and its contibution is important when we want to shorten the examination or when inversion time isn't optimal.

  6. Cine viability magnetic resonance imaging of the heart without increased scan time.

    Science.gov (United States)

    Hassanein, Azza S; Khalifa, Ayman M; Ibrahim, El-Sayed H

    2016-02-01

    Cardiac magnetic resonance imaging (MRI) provides information about myocardial morphology, function, and viability from cine, tagged, and late gadolinium enhancement (LGE) images, respectively. While the cine and tagged images are acquired in a time-resolved fashion, the LGE images are acquired at a single timeframe. The purpose of this work is to develop a method for generating cine LGE images without additional scan time. The motion field is extracted from the tagged images, and is then used to guide the deformation of the infarcted region from the acquired LGE image at the acquired timeframe to any other timeframe. Major techniques for motion estimation, including harmonic phase (HARP) and optical flow analysis, are tested in this work for motion estimation. The proposed method is tested on numerical phantom and images from four human subjects. The generated cine LGE images showed both viability and wall motion information in the same set of images without additional scan time or image misregistration problems. The band-pass optical flow analysis resulted in the most accurate motion estimation compared to other methods, especially HARP, which fails to track points at the myocardial boundary. Infarct transmurality from the generated images showed good agreement with myocardial strain, and wall thickening showed good agreement with that measured from conventional cine images. In conclusion, the developed technique allows for generating cine LGE images that enable simultaneous display of wall motion and viability information. The generated images could be useful for estimating myocardial contractility reserve and for treatment prognosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Subacute and Chronic Left Ventricular Myocardial Scar: Accuracy of Texture Analysis on Nonenhanced Cine MR Images.

    Science.gov (United States)

    Baessler, Bettina; Mannil, Manoj; Oebel, Sabrina; Maintz, David; Alkadhi, Hatem; Manka, Robert

    2018-01-01

    Purpose To test whether texture analysis (TA) allows for the diagnosis of subacute and chronic myocardial infarction (MI) on noncontrast material-enhanced cine cardiac magnetic resonance (MR) images. Materials and Methods In this retrospective, institutional review board-approved study, 120 patients who underwent cardiac MR imaging and showed large transmural (volume of enhancement on late gadolinium enhancement [LGE] images >20%, n = 72) or small (enhanced volume ≤20%, n = 48) subacute or chronic ischemic scars were included. Sixty patients with normal cardiac MR imaging findings served as control subjects. Regions of interest for TA encompassing the left ventricle were drawn by two blinded, independent readers on cine images in end systole by using a freely available software package. Stepwise dimension reduction and texture feature selection based on reproducibility, machine learning, and correlation analyses were performed for selecting features, enabling the diagnosis of MI on nonenhanced cine MR images by using LGE imaging as the standard of reference. Results Five independent texture features allowed for differentiation between ischemic scar and normal myocardium on cine MR images in both subgroups: Teta1, Perc.01, Variance, WavEnHH.s-3, and S(5,5)SumEntrp (in patients with large MI: all P values cine MR images, with an area under the curve of 0.93 and 0.92, respectively. Conclusion This proof-of-concept study indicates that TA of nonenhanced cine MR images allows for the diagnosis of subacute and chronic MI with high accuracy. © RSNA, 2017 Online supplemental material is available for this article.

  8. Evaluation of valvular regurgitation by cine magnetic resonance imaging in patients with various cardiac diseases

    International Nuclear Information System (INIS)

    Kubota, Shuuhei; Nishimura, Tsunehiko

    1990-01-01

    In order to evaluate the clinical value and limitation of magnetic resonance imaging (MRI) for detection and quantification of valvular regurgitation, 98 patients with various cardiac diseases were studied by cine MRI and the results were compared with contrast angiography and doppler color-flow imaging. Cine MRI was carried out using FLASH (fast low angle shot) which employs TE of 10∼20 msec and TR of 30∼40 msec. 22 transverse tomograms per cardiac cycle with a slice thickness of 10 mm were obtained at the level of atrium and ventricle. The jet of valvular regurgitation was easily seen as a discrete are of low signal with cine MRI. Identification of the regurgitation and its severity were visually evaluated based on the relative size of the regurgitant jet from the incompetent valve orifice. Using contrast angiography as a gold standard, the sensitivity of cine MRI for detecting mitral regurgitation was 83% and was 94% for aortic regurgitation, with the specificity of 82% and 100%, respectively. For mitral requrgitation and aortic regurgitation, evaluation by cine MRI and severity agreed well with contrast angiography. By the comparative study with doppler color-flow imaging, relatively good agreement was found between the two methods in detection and quantitative evaluation of valvular regurgitation in any of four valves. Cine MRI was suggested to be useful for both the detection and semiquantification of valvular regurgitation in generally, but its clinical limitation at this point was also found because, 1)its images are not acquired in real times, as in contrast angiography or doppler color-flow imaging, but are compiled from the cumulative information from 128 heart beats, 2)the evaluation of regurgitation is made from only two-dimensional transverse tomograms. (author)

  9. Inferior alveolar canal course: a radiographic study.

    Science.gov (United States)

    Liu, Tie; Xia, Bing; Gu, Zhiyuan

    2009-11-01

    To describe the morphology and course of the inferior alveolar canal (IAC) as it appears in digital panoramic radiographs. Three hundred and eighty-six digital rotational panoramic radiographs (OPG) were studied using the Clinview Software (6.1.3.7 version, Instrumentarium). Among the 386 radiographs, 86 radiographs with 5-mm steel balls were used to calculate the magnification. The average magnification of radiographs in this study was 7.24+/-7.55%. The course of IAC as seen in the panoramic radiograph may be classified into four types: (1) linear curve, 12.75%, (2) spoon-shaped curve, 29.25%, (3) elliptic-arc curve, 48.5%, and (4) turning curve, 9.5%. On panoramic radiographs, the IAC appeared closest to the inferior border of the mandible in the region of the first molar. In relation to the teeth, on panoramic radiographs, the IAC appeared closest to the distal root tip of the third molar and furthest from the mesial root tip of the first molar. In the OPG, there are four types of IAC: linear, spoon shape, elliptic-arc, and turning curve. The data found in the study may be useful for dental implant, mandibule surgery, and dental anesthesia. The limitations of the panoramic radiograph in depicting the true three-dimensional (3D) morphology of the IAC are recognized, computed tomography (CT) and cone beam (CB)3D imaging being more precise.

  10. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...... (twice enlarged) and on duplicating film (original size)....

  11. Bienvenido Mister Cine a la enseñanza de las ciencias

    Directory of Open Access Journals (Sweden)

    Francisco José García Borrás

    2009-01-01

    Full Text Available El profesor de ciencias tiene al alcance de su mano una base de datos increíble, el cine. De este recurso se puede extraer gran cantidad de información. A través de este escrito se procura mostrar como el cine se puede considerar un medio realmente inestimable en la creación de prácticas educativas que fomentan el proceso deenseñanza-aprendizaje, tales como la crítica, la observación, la reflexión e incluso la investigación.

  12. Análisis de las políticas de fomento del cine en Colombia

    OpenAIRE

    Acosta Lara, Bibiana Paola

    2009-01-01

    En esta monografía se analizan las acciones y decisiones impulsadas por el gobierno colombiano para fomentar y fortalecer la industria cinematográfica colombiana. Primero se hará un recuento de la historia del cine colombiano desde la llegada del cinematógrafo al país, poniendo especial énfasis en los intentos de fomento a la industria cinematográfica nacional antes de la entrada en vigor de la Ley General de Cultura y la Ley del Cine, que se analizan por separado, para ver de qué manera ...

  13. Three-dimensional visualization of myocardial motion and blood flow with cine-MR images

    International Nuclear Information System (INIS)

    Oshiro, Osamu; Matani, Ayumu; Chihara, Kunihiro; Mikami, Taisei; Kitabatake, Akira.

    1997-01-01

    This paper describes a three-dimensional (3D) reconstruction and presentation method to visualize myocardial motion and blood flow in a heart using cine-MR (magnetic resonance) images. Firstly, the region of myocardium and blood were segmented with certain threshold gray values. Secondly, some slices were interpolated linearly to reconstruct a 3D static image. Finally, a 3D dynamic image was presented with displaying the 3D static images sequentially. The experimental results indicate that this method enables to visualize not only normal but also abnormal blood flow in cine-mode. (author)

  14. ¿Cómo imagina el cine de Hollywood la publicidad del futuro?

    OpenAIRE

    Pérez Ciprián, Juan Carlos

    2016-01-01

    El trabajo pretende investigar cómo el cine de Hollywood imagina la publicidad cuando ambienta sus películas en mundos futuristas. Tartiendo de un corpus compuesto por diecinueve películas posteriores a "Blade Runner", estrenedo en 1982 y obra que cambió el género de la ciencia ficción, se procederá a examinar los distintos formatos publicitarios y el contenido de los mensajes que aparecen en los mismos. Comprobando si la publicidad es tenida en cuenta por los conceptualistas de cine a la ho...

  15. 2ª Muestra de Cine Español en la Biblioteca (febrero-marzo 2006)

    OpenAIRE

    Punt BIU

    2006-01-01

    2ª Muestra de Cine Español en la Biblioteca (febrero-marzo 2006) = 2ª Mostra de Cinema Espanyol en la Biblioteca (febrer-març 2006). Incluye los siguientes folletos: Cine y literatura = Cinema i literatura; Cortometrajes = Curtmetratges; Cuatro generaciones = Quatre generacions: Buñuel, Berlanga, Garci y Amenábar; Guiones cinematográficos = Guions cinematogràfics; Mujeres directoras = Dones directores; Versión española: doblaje y coproducciones = Versió espanyola: doblatge i coproduccions....

  16. La música incidental en el cine y el teatro

    OpenAIRE

    Olarte Martínez, Matilde María

    2002-01-01

    [ES] Este artículo revisa el papel protagonista de la música incidental en el cine y en el teatro, partiendo de la definición estricta de música incidental y accidental, revisando las principales evoluciones que la música incidental ha experimentado en el cine, y deteniéndose en el género del musical, como un ejemplo significativo de la creación incidental musical actual. [EN] In this article we study the main role of the incidental music for films and theatre plays, starting from the stri...

  17. Routine cine-CMR for prosthesis-associated mitral regurgitation: a multicenter comparison to echocardiography.

    Science.gov (United States)

    Simprini, Lauren A; Afroz, Anika; Cooper, Mitchell A; Klem, Igor; Jensen, Christoph; Kim, Raymond J; Srichai, Monvadi B; Heitner, John F; Sood, Michael; Chandy, Elizabeth; Shah, Dipan J; Lopez-Mattei, Juan; Biederman, Robert W; Grizzard, John D; Fuisz, Anthon; Ghafourian, Kambiz; Farzaneh-Far, Afshin; Weinsaft, Jonathan

    2014-09-01

    Mitral regurgitation (MR) is an important complication after prosthetic mitral valve (PMV) implantation. Transthoracic echocardiography is widely used to screen for native MR, but can be limited with PMV. Cine-cardiac magnetic resonance (CMR) holds the potential for the non-invasive assessment of regurgitant severity based on MR-induced inter-voxel dephasing. The study aim was to evaluate routine cine-CMR for the visual assessment of PMV-associated MR. Routine cine-CMR was performed at nine sites. A uniform protocol was used to grade MR based on jet size in relation to the left atrium (mild 2/3). MR was graded in each long-axis orientation, with overall severity based on cumulative grade. Cine-CMR was also scored for MR density and pulmonary vein systolic flow reversal (PVSFR). Visual interpretation was compared to quantitative analysis in a single-center (derivation) cohort, and to transesophageal echocardiography (TEE) in a multicenter (validation) cohort. The population comprised 85 PMV patients (59% mechanical valves, 41% bioprostheses). Among the derivation cohort (n = 25), quantitative indices paralleled visual scores, with stepwise increases in jet size and density in relation to visually graded MR severity (both p = 0.001). Patients with severe MR had an almost three-fold increase in quantitative jet area (p = 0.002), and a two-fold increase in density (p = 0.04) than did other patients. Among the multicenter cohort, cine-CMR and TEE (Δ =. 2 ± 3 days) demonstrated moderate agreement (κ = 0.44); 64% of discordances differed by ≤ 1 grade (Δ = 1.2 ± 0.5). Using a TEE reference, cine-CMR yielded excellent diagnostic performance for severe MR (sensitivity, negative predictive value = 100%). Patients with visually graded severe MR also had more frequent PVSFR (p cine-CMR. Cine-CMR is useful for the assessment of PMV-associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter-voxel dephasing. Visual MR

  18. El cine de animación visto en casa: dibujos animados y TV

    OpenAIRE

    Núñez Domínguez, Trinidad; Loscertales Abril, Felicidad

    2008-01-01

    El cine es objeto de estudio para la Psicología Social porque no sólo es arte o industria; es socialización. Porque muestra modelos de comportamiento, valores sociales y normas, produce reacciones: es persuasivo. Este aspecto es el que mejor justifica el análisis psicosocial. También en muchas ocasiones, el cine presenta unos contenidos con prejuicios negativos poco explícitos, muy sutiles y, por tanto, bastantes peligrosos. Analizamos diez conocidas películas Disney desde la perspectiva de g...

  19. El jugador implicado en el cine. Adaptaciones de videojuegos a películas

    OpenAIRE

    Anyó, Lluís

    2017-01-01

    La figura teórica del jugador implicado indica una característica fundamental de los videojuegos: su jugabilidad o relato dinámico. A partir de este concepto, se analiza distintos tipos de adaptación de los videojuegos al cine, de acuerdo con una definición amplia de la adaptación. Entendemos adaptación como un proceso de transformación de un lenguaje a otro, una traducción que puede ser directa o indirecta. Las adaptaciones, en el caso de los videojuegos al cine, pueden dividirse en tres tip...

  20. El cine mexicano de la edad de oro y su impacto internacional

    OpenAIRE

    Maricruz Castro-Ricalde

    2014-01-01

    A partir de una investigación documental en publicaciones periódicas de Argentina, Colombia, Cuba, Chile, Estados Unidos, Honduras, México, Nicaragua y Venezuela, este artículo demuestra el interés que el cine mexicano producido entre 1936 y 1956 provocó en los espectadores de Hispanoamérica y Estados Unidos, al igual que la presencia de actores, cineastas, temas y personajes de otros países hispanohablantes en la industria cinematográfica mexicana durante la denominada edad de oro del cine m...

  1. Nuevos planes, idénticas estrategias: apuntes sobre un cine asturiano actual

    Directory of Open Access Journals (Sweden)

    Pablo Sánchez Blasco

    2014-12-01

    Full Text Available Este artículo hace un repaso a la situación del audiovisual asturiano con especial hincapié en los últimos tres años. Tras la desaparición de las subvenciones y los presupuestos para cine, ha surgido una serie de nombres que ruedan sus proyectos al margen de la industria y que han normalizado el largometraje de ficción comoobjetivo a su alcance. Sus características les hermanan al cine alternativo aparecido en Españaaunque, al mismo tiempo, ofrecen rasgos particulares que matizan su definición.

  2. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  3. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  4. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  5. Radiographic study of the odontoma

    International Nuclear Information System (INIS)

    Ahn, Hyung Kyu

    1983-01-01

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  6. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  7. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  8. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  9. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  10. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  11. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  12. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  13. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  14. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  15. Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.

    Science.gov (United States)

    Jeong, Daniel; Schiebler, Mark L; Lai, Peng; Wang, Kang; Vigen, Karl K; François, Christopher J

    2015-04-01

    Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left ventricular function. CMR examinations were performed on fifteen patients and three healthy volunteers on a clinical 1.5T scanner using a two-dimensional (2D) cine balanced SSFP CMR sequence (2D cine bSSFP) followed by an investigational 3D cine bSSFP pulse sequence acquired within a single breath hold. Left ventricular end diastolic volume (LVEDV), end systolic volume (LVESV), ejection fraction (LVEF), and myocardial mass were independently segmented on a workstation by two experienced radiologists. Blood pool to myocardial contrast was evaluated in consensus using a Likert scale. Bland-Altman analysis was used to compare these quantitative and nominal measurements for the two sequences. The average acquisition time was significantly shorter for the 3D cine bSSFP than for 2D cine bSSFP (0.36 ± 0.03 vs. 8.5 ± 2.3 min) p = 0.0002. Bland-Altman analyses [bias and (limits of agreement)] of the data derived from these two methods revealed that the LVEF 0.9% (-4.7, 6.4), LVEDV 4.9 ml (-23.0, 32.8), LVESV -0.2 ml (-22.4, 21.9), and myocardial mass -0.4 g (-23.8, 23.0) were not significantly different. There was excellent intraclass correlation for intra-observer variability (0.981, 0.989, 0.997, 0.985) and inter-observer variability (0.903, 0.954, 0.970, 0.842) for LVEF, LVEDV, LVESV, and myocardial mass respectively. 3D cine bSSFP allows for accurate single breath-hold volumetric cine CMR which enables substantial improvements in scanner time efficiency without sacrificing diagnostic accuracy.

  16. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    Energy Technology Data Exchange (ETDEWEB)

    Bawazeer, O; Deb, P [RMIT University, Melbourne, VIC (Australia); Sarasanandarajah, S [Peter MacCallum Cancer Institute, Melbourne, Victoria (Australia); Herath, S; Kron, T [Peter MacCallum Cancer Institute, Melbourne, VIC (Australia)

    2016-06-15

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

  17. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    International Nuclear Information System (INIS)

    Bawazeer, O; Deb, P; Sarasanandarajah, S; Herath, S; Kron, T

    2016-01-01

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

  18. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  19. Chest radiographic findings in acute paraquat poisoning

    International Nuclear Information System (INIS)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O

    2016-01-01

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation

  20. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  1. Right ventricular volume and mass determined by cine magnetic resonance imaging in HIV patients with possible right ventricular dysfunction

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette; Gerstoft, Jan

    2006-01-01

    Impaired right ventricular (RV) function has been reported to occur in patients with HIV when studied by echocardiography. However, for accurate evaluation of RV function and morphology, first-pass radionuclide ventriculography (RNV) and cine magnetic resonance imaging (cine-MRI) are methods...... ventricular ejection fraction (RVEF). To do so, we screened patients with RNV and performed an additional cine-MRI in those with reduced RVEF determined by RNV. Ninety patients with HIV were included. To evaluate the MRI measures exactly we included 18 age- and gender-matched healthy volunteers to establish...

  2. Cine y vanguardias artística: conflictos, encuentros, fronteras [Prólogo e introducción

    OpenAIRE

    Sánchez-Biosca, Vicente

    2004-01-01

    El cine y la vanguardia estaban condenados a encontrarse. Ambos fueron producto del paso del siglo XIX al XX; ambos ambicionaban rupturas y creían ser el punto de partida de una nueva era. Sin embargo, los encuentros no fueron inmediatos y sobre todo, el cine se aventuró pronto en caminos comerciales y narrativos ajenos, incluso opuestos, a los de la vanguardia. Así la condición vanguardiasta del cine plantea desde sus mismos orígenes problemas de definición que no han preocupado tanto a los ...

  3. Dos Tiempos para la Utopía: Festivales de Cine Latinoamericano Twice for Utopia: Latin American Film Festivals

    OpenAIRE

    José Román R

    2010-01-01

    Los dos festivales de cine latinoamericano celebrados en Viña del Mar en 1967 y 1969, tuvieron como tema principal las relaciones entre cine y política. Las películas presentadas provenían de movimientos caracterizados como «nuevo cine», en oposición al que dominaba las pantallas del continente. La mayoría de ellas buscaban representar la realidad social y política de sus países. En paralelo a la exhibición de los filmes, los cineastas invitados debatían sobre los grandes temas que agitaban a...

  4. Cine-servo lens technology for 4K broadcast and cinematography

    Science.gov (United States)

    Nurishi, Ryuji; Wakazono, Tsuyoshi; Usui, Fumiaki

    2015-09-01

    Central to the rapid evolution of 4K image capture technology in the past few years, deployment of large-format cameras with Super35mm Single Sensors is increasing in TV production for diverse shows such as dramas, documentaries, wildlife, and sports. While large format image capture has been the standard in the cinema world for quite some time, the recent experiences within the broadcast industry have revealed a variety of requirement differences for large format lenses compared to those of the cinema industry. A typical requirement for a broadcast lens is a considerably higher zoom ratio in order to avoid changing lenses in the middle of a live event, which is mostly not the case for traditional cinema productions. Another example is the need for compact size, light weight, and servo operability for a single camera operator shooting in a shoulder-mount ENG style. On the other hand, there are new requirements that are common to both worlds, such as smooth and seamless change in angle of view throughout the long zoom range, which potentially offers new image expression that never existed in the past. This paper will discuss the requirements from the two industries of cinema and broadcast, while at the same time introducing the new technologies and new optical design concepts applied to our latest "CINE-SERVO" lens series which presently consists of two models, CN7x17KAS-S and CN20x50IAS-H. It will further explain how Canon has realized 4K optical performance and fast servo control while simultaneously achieving compact size, light weight and high zoom ratio, by referring to patent-pending technologies such as the optical power layout, lens construction, and glass material combinations.

  5. Copper-Catalyzed Heteroarylboration of 1,3-Dienes with 3-Bromopyridines: A cine Substitution.

    Science.gov (United States)

    Smith, Kevin B; Huang, Yuan; Brown, M Kevin

    2018-04-26

    A method for the heteroarylboration of 1,3-dienes is presented. The process involves an unusual cine substitution of 3-bromopyridine derivatives to deliver highly functionalized heterocyclic products. Mechanistic studies are included that clarify the details of this unusual process. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Evaluation of right ventricular regional wall motion in inferior myocardial infarction by cine MRI

    International Nuclear Information System (INIS)

    Nishino, Masami; Ohnishi, Shusaku; Hasegawa, Shinji

    1991-01-01

    The purpose of this study is to evaluate right ventricular regional wall motion in inferior myocardial infarction by cine MRI. Thirteen patients with inferior myocardial infarction were investigated by cine MRI and were divided into proximal group which consisted of seven patients: >90% stenosis in segment 1 or 2 of right coronary artery and distal group which consisted of six patients: >90% stenosis in segment 3 or 4 of right coronary artery. Cine MRI was performed by 1.5 tesla magnet system (Signa, GE). To depict the regional asynergy, right ventricular wall was divided into 6 segments as follows: Segments 1 and 2 were upper and lower segments in transverse planes, respectively. Segments 3 and 4 were free wall and diaphragmatic segments of outflow tract, and segments 5 and 6 were of inflow tract in sagittal planes. Our results were as follows: (1) In proximal group, right ventricular asynergy was detected in six patients but in distal group it was detected in only one patient; (2) Right ventricular asynergy was detected most frequently at diaphragmatic segments in sagittal planes; (3) All the patients who had shown the hemodynamic deterioration of right ventricle on acute phase of inferior myocardial infarction presented the broad asynergy in right ventricle; (4) Cine MRI is clinically useful in evaluating right ventricular regional wall movement and diagnosing right ventricular infarction. (author)

  7. La cultura en el trimestre: El cine en la televisión

    Directory of Open Access Journals (Sweden)

    José Gabriel Baena

    1985-06-01

    Full Text Available Como parte de estas políticas de Focine de apoyar logística y financieramente a los nuevos creadores y realizadores de cine en Colombia, se convocó a un primer concurso de guiones originales y adaptaciones de obras literarias, del cual resultó una decena de autores premiados.

  8. Dynamic change in size of the lateral ventricle evaluated by cine MRI

    International Nuclear Information System (INIS)

    Abe, Toshi

    1990-01-01

    CSF pulsation suggests variation in the size of the cerebral ventricle during the cardiac cycle. CINE MRI, which is a useful technique for observation of the pulsatile CSF flow, demonstrates a dynamic change in size of the lateral ventricle. CINE MRI was performed on a 0.5 tesla MR imaging system (SMT-50, SHIMADZU). Sixteen different phased images during cardiac cycle were made by a gradient acho technique (STAGE: Short Tip Angle Gradient Echo, TE=14 msec, Flip Angle=30deg). From the measurement of the lateral ventricular areas of two different phases of CINE MRI during cadiac cycle, variation rate of cerebral ventricular area (VRCVA) was calculated. Twenty-five normal volunteers (14 younger adults aged 27-44 years, 11 older adults aged 56-73 years) and six cases of marked diffuse cerebral atrophy were studied. The results included: The mean VRCVA of younger adults was 14.4% (at right body of lateral ventricle) ∼ 30.0% (at left anterior horn of lateral ventricle). The mean VRCVA of younger adults is higher than the mean VRCVA of older adults. In the cases of marked diffuse cerebral atrophy, the mean VRCVA was very lower than the mean VRCVA of older adults. VRCVA of lateral ventricle calculated from CINE MRI seemed to have a good relationship to the brain elasticity. This noninvasive method would be used as an indication of the elastic response of the ventricles and the surrounding brain. (J.P.N.)

  9. Roles femeninos en el cine de migraciones en España

    Directory of Open Access Journals (Sweden)

    María Jesús Alonso Seoane

    2011-10-01

    Full Text Available El estudio del cine como medio para el análisis sociológico es poco frecuente todavía en nuestro país. Existen numerosos artículos analizando el cine desde diversos ángulos, también el femenino, especialmente roles como el de la mujer fatal en el cine negro. Pero es menos habitual emplear este formato como parte de un método analítico del que extraer un reflejo social de lo que las pantallas proyectan y, a un tiempo, contribuyen a legitimar como base de una sociedad futura. No obstante, existen pocos medios que sean capaces de reflejar el gran cambio acaecido en la historia reciente de la sociedad española. Este interés documental incrementa su potencial al enfocar en primer plano a las mujeres. Este artículo es una contribución a estudiar un campo tan atractivo como es el cine de migraciones a través de la óptica de los imaginarios sociales.

  10. Assessment of Bladder Motion for Clinical Radiotherapy Practice Using Cine-Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    McBain, Catherine A.; Khoo, Vincent S.; Buckley, David L.; Sykes, Jonathan S.; Green, Melanie M.; Cowan, Richard A.; Hutchinson, Charles E.; Moore, Christopher J.; Price, Patricia M.

    2009-01-01

    Purpose: Organ motion is recognized as the principal source of inaccuracy in bladder radiotherapy (RT), but there is currently little information on intrafraction bladder motion. Methods and Materials: We used cine-magnetic resonance imaging (cine-MRI) to study bladder motion relevant to intrafraction RT delivery. On two occasions, a 28 minute cine-MRI sequence was acquired from 10 bladder cancer patients and 5 control participants immediately after bladder emptying, after abstinence from drinking for the preceding hour. From the resulting cine sequences, bladder motion was subjectively assessed. To quantify bladder motion, the bladder was contoured in imaging volume sets at 0, 14, and 28 min to measure changes to bladder volumes, wall displacements, and center of gravity (COG) over time. Results: The dominant source of bladder motion during imaging was bladder filling (up to 101% volume increase); rectal and small bowel movements were transient, with minimal impact. Bladder volume changes were similar for all participants. However for bladder cancer patients, wall displacements were larger (up to 58 mm), less symmetrical, and more variable compared with nondiseased control bladders. Conclusions: Significant and individualized intrafraction bladder wall displacements may occur during bladder RT delivery. This important source of inaccuracy should be incorporated into treatment planning and verification.

  11. El cine como herramienta docente en bioética y tanatología

    OpenAIRE

    Ogando Díaz, Beatriz

    2010-01-01

    El objetivo de esta tesis es desarrollar una metodología docente en bioética del final de la vida a través de la utilización del cine como herramienta pedagógica para los estudios de pregrado, posgrado y especialización en Medicina.

  12. Volumetric Arterial Wall Shear Stress Calculation Based on Cine Phase Contrast MRI

    NARCIS (Netherlands)

    Potters, Wouter V.; van Ooij, Pim; Marquering, Henk; VanBavel, Ed; Nederveen, Aart J.

    2015-01-01

    PurposeTo assess the accuracy and precision of a volumetric wall shear stress (WSS) calculation method applied to cine phase contrast magnetic resonance imaging (PC-MRI) data. Materials and MethodsVolumetric WSS vectors were calculated in software phantoms. WSS algorithm parameters were optimized

  13. Functional imaging of murine hearts using accelerated self-gated UTE cine MRI

    NARCIS (Netherlands)

    Motaal, Abdallah G.; Noorman, Nils; de Graaf, Wolter L.; Hoerr, Verena; Florack, Luc M. J.; Nicolay, Klaas; Strijkers, Gustav J.

    2015-01-01

    We introduce a fast protocol for ultra-short echo time (UTE) Cine magnetic resonance imaging (MRI) of the beating murine heart. The sequence involves a self-gated UTE with golden-angle radial acquisition and compressed sensing reconstruction. The self-gated acquisition is performed asynchronously

  14. Spirometer-controlled Cine-Magnetic Resonance Imaging for Diagnosis of Tracheobronchomalacia in Pediatric Patients

    NARCIS (Netherlands)

    Ciet, P.; Wielopolski, P.; Manniesing, R.; Lever, S.; Bruijne, M. de; Morana, G.; Muzzio, P.C.; Lequin, M.H.; Tiddens, H.A.W.M.

    2014-01-01

    Tracheobronchomalacia (TBM) is defined as an excessive collapse of the intrathoracic trachea. Bronchoscopy is the gold standard to diagnose TBM, but bronchoscopy has major disadvantages, such as general anaesthesia. Cine-CT is a non-invasive alternative to diagnose TBM, but its use in children is

  15. Higher resolution cine imaging with compressed sensing for accelerated clinical left ventricular evaluation.

    Science.gov (United States)

    Lin, Aaron C W; Strugnell, Wendy; Riley, Robyn; Schmitt, Benjamin; Zenge, Michael; Schmidt, Michaela; Morris, Norman R; Hamilton-Craig, Christian

    2017-06-01

    To assess the clinical feasibility of a compressed sensing cine magnetic resonance imaging (MRI) sequence of both high temporal and spatial resolution (CS_bSSFP) in comparison to a balanced steady-state free precession cine (bSSFP) sequence for reliable quantification of left ventricular (LV) volumes and mass. Segmented MRI cine images were acquired on a 1.5T scanner in 50 patients in the LV short-axis stack orientation using a retrospectively gated conventional bSSFP sequence (generalized autocalibrating partially parallel acquisition [GRAPPA] acceleration factor 2), followed by a prospectively triggered CS_bSSFP sequence with net acceleration factor of 8. Image quality was assessed by published criteria. Comparison of sequences was made in LV volumes and mass, image quality score, quantitative regional myocardial wall motion, and imaging time using Pearson's correlation, Bland-Altman and paired 2-tailed Student's t-test. Differences (bSSFP minus CS_bSSFP, mean ± SD) and Pearson's correlations were 14.8 ± 16.3 (P = 0.31) and r = 0.98 (P cine CS_bSSFP accurately and reliably quantitates LV volumes and mass, shortens acquisition times, and is clinically feasible. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1693-1699. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction

    NARCIS (Netherlands)

    Motaal, Abdallah G.; Coolen, Bram F.; Abdurrachim, Desiree; Castro, Rui M.; Prompers, Jeanine J.; Florack, Luc M. J.; Nicolay, Klaas; Strijkers, Gustav J.

    2013-01-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensi ng reconstruction. Key to our

  17. Imaging Three-Dimensional Myocardial Mechanics Using Navigator-gated Volumetric Spiral Cine DENSE MRI

    Science.gov (United States)

    Zhong, Xiaodong; Spottiswoode, Bruce S.; Meyer, Craig H.; Kramer, Christopher M.; Epstein, Frederick H.

    2010-01-01

    A navigator-gated 3D spiral cine displacement encoding with stimulated echoes (DENSE) pulse sequence for imaging 3D myocardial mechanics was developed. In addition, previously-described 2D post-processing algorithms including phase unwrapping, tissue tracking, and strain tensor calculation for the left ventricle (LV) were extended to 3D. These 3D methods were evaluated in 5 healthy volunteers, using 2D cine DENSE and historical 3D myocardial tagging as reference standards. With an average scan time of 20.5 ± 5.7 minutes, 3D data sets with a matrix size of 128 × 128 × 22, voxel size of 2.8 × 2.8 × 5.0 mm3, and temporal resolution of 32 ms were obtained with displacement encoding in three orthogonal directions. Mean values for end-systolic mid-ventricular mid-wall radial, circumferential, and longitudinal strain were 0.33 ± 0.10, −0.17 ± 0.02, and −0.16 ± 0.02, respectively. Transmural strain gradients were detected in the radial and circumferential directions, reflecting high spatial resolution. Good agreement by linear correlation and Bland-Altman analysis was achieved when comparing normal strains measured by 2D and 3D cine DENSE. Also, the 3D strains, twist, and torsion results obtained by 3D cine DENSE were in good agreement with historical values measured by 3D myocardial tagging. PMID:20574967

  18. Analysis of 3-D Tongue Motion from Tagged and Cine Magnetic Resonance Images

    Science.gov (United States)

    Xing, Fangxu; Woo, Jonghye; Lee, Junghoon; Murano, Emi Z.; Stone, Maureen; Prince, Jerry L.

    2016-01-01

    Purpose: Measuring tongue deformation and internal muscle motion during speech has been a challenging task because the tongue deforms in 3 dimensions, contains interdigitated muscles, and is largely hidden within the vocal tract. In this article, a new method is proposed to analyze tagged and cine magnetic resonance images of the tongue during…

  19. Tissue-Point Motion Tracking in the Tongue from Cine MRI and Tagged MRI

    Science.gov (United States)

    Woo, Jonghye; Stone, Maureen; Suo, Yuanming; Murano, Emi Z.; Prince, Jerry L.

    2014-01-01

    Purpose: Accurate tissue motion tracking within the tongue can help professionals diagnose and treat vocal tract--related disorders, evaluate speech quality before and after surgery, and conduct various scientific studies. The authors compared tissue tracking results from 4 widely used deformable registration (DR) methods applied to cine magnetic…

  20. Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories.

    Science.gov (United States)

    Tolouee, Azar; Alirezaie, Javad; Babyn, Paul

    2015-11-01

    In dynamic cardiac cine Magnetic Resonance Imaging (MRI), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D+time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  2. Tracheomalacia in adults with cystic fibrosis: determination of prevalence and severity with dynamic cine CT.

    LENUS (Irish Health Repository)

    McDermott, Shaunagh

    2012-02-01

    PURPOSE: To determine the prevalence and severity of tracheomalacia in adults with cystic fibrosis (CF) by using dynamic cine multidetector computed tomography (CT) and to correlate these findings with pulmonary function test (PFT) results and the severity of parenchymal lung disease. MATERIALS AND METHODS: In this institutional review board-approved HIPAA-compliant study, 40 patients with CF (22 men, 18 women; mean age, 28 years +\\/- 8 [standard deviation]; age range, 18-54 years) prospectively underwent PFTs, standard thin-section CT, and two dynamic cine multidetector CT acquisitions. Ten control subjects underwent dynamic cine multidetector CT. After standard thin-section CT was completed, dynamic cine multidetector CT was performed during a forced expiratory maneuver and during coughing. Dynamic cine multidetector CT images in nine patients were excluded. Maximal inspiratory, dynamic expiratory, and end-expiratory tracheal luminal areas were compared (Student t test) and correlated (Spearman rank) with PFT results and severity of parenchymal lung disease. RESULTS: Mean predicted forced expiratory volume in 1 second (FEV(1)) was 70.6% +\\/- 20.7, and mean Bhalla CT score was 41.8% +\\/- 13.6. In patients with CF, dynamic cine mean tracheal cross-sectional area reduction was 51.7% +\\/- 18.4 (range, 9%-89%) for forced expiratory maneuvers and 68.8% +\\/- 11.7 (range, 18%-88%) for coughing (P = .001). Tracheomalacia was demonstrated in 24 (69%) patients and no control subjects during forced expiratory maneuvers (P = .001) and in 10 (29%) patients and one (10%) control subject during coughing. For end-expiration images, mean tracheal luminal reduction was 16.1% +\\/- 14.0% (range, 0.0%-53.0%), with one patient demonstrating tracheal luminal reduction of more than 50%. There was no correlation between tracheal cross-sectional luminal reduction and either predicted FEV(1) or CT Bhalla score. CONCLUSION: Tracheomalacia depicted at dynamic cine multidetector CT is a

  3. Routine Cine-CMR for Prosthesis Associated Mitral Regurgitation – A Multicenter Comparison to Echocardiography

    Science.gov (United States)

    Simprini, Lauren A.; Afroz, Anika; Cooper, Mitchell A.; Klem, Igor; Jensen, Christoph; Kim, Raymond J.; Srichai, Monvadi B.; Heitner, John F.; Sood, Michael; Chandy, Elizabeth; Shah, Dipan J.; Lopez-Mattei, Juan; Biederman, Robert W.; Grizzard, John D.; Fuisz, Anthon; Ghafourian, Kambiz; Farzaneh-Far, Afshin; Weinsaft, Jonathan

    2016-01-01

    Background/Aim MR is an important complication after PMV. Transthoracic echocardiography is widely used to screen for native MR, but can be limited with PMV. Cine-CMR holds potential to non-invasively assess regurgitant severity based on MR-induced inter-voxel dephasing. This study evaluated routine cine-CMR for visual assessment of prosthetic mitral valve (PMV) associated mitral regurgitation (MR). Methods Routine cine-CMR was performed at 9 sites. A uniform protocol was used to grade MR based on jet size in relation to the left atrium (mild 2/3): MR was graded in each long axis orientation, with overall severity based on cumulative grade. Cine-CMR was also scored for MR density and pulmonary vein systolic flow reversal (PSFR). Visual interpretation was compared to quantitative analysis in a single center (derivation) cohort, and to transesophageal echocardiography (TEE) in a multicenter (validation) cohort. Results The population comprised 85 PMV patients (59% mechanical, 41% bioprosthetic). Among the derivation cohort (n=25), quantitative indices paralleled visual scores, with stepwise increases in jet size and density in relation to visually graded MR severity (both p=0.001): Patients with severe MR had nearly a 3-fold increase in quantitative jet area (p=0.002), and 2-fold increase in density (p=0.04) than did others. Among the multicenter cohort, cine-CMR and TEE (Δ=2±3 days) demonstrated moderate agreement (κ=0.44); 64% of discordances differed by ≤ 1 grade (Δ=1.2±0.5). Using a TEE reference, cine-CMR yielded excellent diagnostic performance for severe MR (sensitivity, negative predictive value=100%). Patients with visually graded severe MR also had more frequent PVSFR (pcine-CMR. Conclusions Cine-CMR is useful for assessment of PMV-associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter-voxel dephasing. Visual MR assessment based on jet size provides an accurate non-invasive means of screening for

  4. Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging.

    Science.gov (United States)

    Chen, Xiao; Yang, Yang; Cai, Xiaoying; Auger, Daniel A; Meyer, Craig H; Salerno, Michael; Epstein, Frederick H

    2016-06-14

    Cine Displacement Encoding with Stimulated Echoes (DENSE) provides accurate quantitative imaging of cardiac mechanics with rapid displacement and strain analysis; however, image acquisition times are relatively long. Compressed sensing (CS) with parallel imaging (PI) can generally provide high-quality images recovered from data sampled below the Nyquist rate. The purposes of the present study were to develop CS-PI-accelerated acquisition and reconstruction methods for cine DENSE, to assess their accuracy for cardiac imaging using retrospective undersampling, and to demonstrate their feasibility for prospectively-accelerated 2D cine DENSE imaging in a single breathhold. An accelerated cine DENSE sequence with variable-density spiral k-space sampling and golden angle rotations through time was implemented. A CS method, Block LOw-rank Sparsity with Motion-guidance (BLOSM), was combined with sensitivity encoding (SENSE) for the reconstruction of under-sampled multi-coil spiral data. Seven healthy volunteers and 7 patients underwent 2D cine DENSE imaging with fully-sampled acquisitions (14-26 heartbeats in duration) and with prospectively rate-2 and rate-4 accelerated acquisitions (14 and 8 heartbeats in duration). Retrospectively- and prospectively-accelerated data were reconstructed using BLOSM-SENSE and SENSE. Image quality of retrospectively-undersampled data was quantified using the relative root mean square error (rRMSE). Myocardial displacement and circumferential strain were computed for functional assessment, and linear correlation and Bland-Altman analyses were used to compare accelerated acquisitions to fully-sampled reference datasets. For retrospectively-undersampled data, BLOSM-SENSE provided similar or lower rRMSE at rate-2 and lower rRMSE at rate-4 acceleration compared to SENSE (p cine DENSE provided good image quality and expected values of displacement and strain. BLOSM-SENSE-accelerated spiral cine DENSE imaging with 2D displacement encoding can be

  5. Biphosphonate-induced radiographic changes in two pediatric patients with rheumatic diseases

    International Nuclear Information System (INIS)

    Fernandes, Joao L.; Rocha, Arthemizio L.; Viana, Sergio L.; Ribeiro, Maria C.; Castro, Luis C.

    2004-01-01

    Biphosphonates are now being used experimentally in children to increase bone mass, but their long-term effects remain an issue of concern. We report two cases of biphosphonate-induced radiographic changes in children with rheumatic diseases. Our experience supports the view that clinical improvement and radiographic findings after biphosphonate therapy are related to increased bone mineral density, without effects on the inflammatory process itself. Biphosphonates seem to act in rheumatic diseases by reducing bone turnover instead of improving disease activity. (orig.)

  6. Functional imaging of murine hearts using accelerated self-gated UTE cine MRI.

    Science.gov (United States)

    Motaal, Abdallah G; Noorman, Nils; de Graaf, Wolter L; Hoerr, Verena; Florack, Luc M J; Nicolay, Klaas; Strijkers, Gustav J

    2015-01-01

    We introduce a fast protocol for ultra-short echo time (UTE) Cine magnetic resonance imaging (MRI) of the beating murine heart. The sequence involves a self-gated UTE with golden-angle radial acquisition and compressed sensing reconstruction. The self-gated acquisition is performed asynchronously with the heartbeat, resulting in a randomly undersampled kt-space that facilitates compressed sensing reconstruction. The sequence was tested in 4 healthy rats and 4 rats with chronic myocardial infarction, approximately 2 months after surgery. As a control, a non-accelerated self-gated multi-slice FLASH sequence with an echo time (TE) of 2.76 ms, 4.5 signal averages, a matrix of 192 × 192, and an acquisition time of 2 min 34 s per slice was used to obtain Cine MRI with 15 frames per heartbeat. Non-accelerated UTE MRI was performed with TE = 0.29 ms, a reconstruction matrix of 192 × 192, and an acquisition time of 3 min 47 s per slice for 3.5 averages. Accelerated imaging with 2×, 4× and 5× undersampled kt-space data was performed with 1 min, 30 and 15 s acquisitions, respectively. UTE Cine images up to 5× undersampled kt-space data could be successfully reconstructed using a compressed sensing algorithm. In contrast to the FLASH Cine images, flow artifacts in the UTE images were nearly absent due to the short echo time, simplifying segmentation of the left ventricular (LV) lumen. LV functional parameters derived from the control and the accelerated Cine movies were statistically identical.

  7. Radiographic evaluation of AIDS patients

    Energy Technology Data Exchange (ETDEWEB)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V. [Miami Univ., FL (United States). Dept. of Radiology

    1995-09-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts.

  8. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  9. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V.

    1995-01-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  10. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  11. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms : Implications for endograft treatment

    NARCIS (Netherlands)

    Teutelink, A; Rutten, A; Muhs, BE; Olree, M; van Herwaarden, JA; de Vos, AM; Prokop, M; Moll, FL; Verhagen, HJM

    Purpose: To utilize 40-slice electrocardiographically (ECG)-gated cine computed tomographic angiography (CTA) to characterize normal aortic motion during the cardiac cycle at relevant anatomical landmarks in preoperative abdominal aortic aneurysm (AAA) patients. Methods: In 10 consecutive

  12. Radiographer-performed stereotactic needle core biopsy: Making a difference

    International Nuclear Information System (INIS)

    Dixon, Anne-Marie; Dearnley, Christine

    2008-01-01

    This case study describes a qualitative investigation of the experiences of 14 experienced mammography radiographers who successfully undertook a formal programme of education and training in stereotactic needle core biopsy (SNCB) of the breast. They now routinely perform SNCB within symptomatic and screening breast services in a variety of NHS hospitals across the country. All 14 radiographers completed a semi-structured postal questionnaire approximately six months after the end of the course. A tentative theory derived from the data suggests that the professional challenge associated with radiographer-performed SNCB builds personal confidence and effects positive change. Three main categories emerging from the data - challenge, confidence and change are underpinned by two main themes - educational, professional and service drivers that promote the realisation of goals and vision; and personal, peer and external motivation sustained by respect, recognition and reward. SNCB role extension as explored in this study is having a positive and transformational impact on patient users of breast diagnostic clinical services and on the professional health carers providing them. The key drivers for this as identified in the study are a formal educational experience, professional role extension opportunities and the NHS modernisation process. The participants experienced positive change as individuals and as professional breast cancer multidisciplinary team members. Academic and financial rewards, respect and recognition from colleagues across professional disciplines and from patients, were key motivators that sustained the process. This study indicates that radiographer-performed SNCB can help deliver the NHS Plan and the NHS Cancer Plan and in doing so has the potential to improve the working lives of health care professionals and ultimately to improve the quality of care for patients

  13. Assessment of small bowel motility in patients with chronic intestinal pseudo-obstruction using cine-MRI.

    Science.gov (United States)

    Ohkubo, Hidenori; Kessoku, Takaomi; Fuyuki, Akiko; Iida, Hiroshi; Inamori, Masahiko; Fujii, Tetsuro; Kawamura, Harunobu; Hata, Yasuo; Manabe, Noriaki; Chiba, Toshimi; Kwee, Thomas C; Haruma, Ken; Matsuhashi, Nobuyuki; Nakajima, Atsushi; Takahara, Taro

    2013-07-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare, serious motility disorder, with life-threatening complications over time. However, lack of an established, non-invasive diagnostic method has caused delays in the diagnosis of this intractable disease. Cine-magnetic resonance imaging (MRI) is an emerging technique, with a potential to evaluate the motility of the entire bowel. We compared small bowel motility in healthy volunteers, patients with irritable bowel syndrome (IBS), and those with CIPO, using cine-MRI, and evaluated the usefulness of cine-MRI as a novel diagnostic method for CIPO. Twelve healthy volunteers, IBS patients, and CIPO patients prospectively underwent cine-MRI at 1.5 T. Luminal diameter, contraction ratio, and contraction cycle were measured and compared between the groups. Cine-MRI provided sufficient dynamic images to assess the motility of the entire small bowel. Luminal diameter (mean±s.d.) in CIPO patients was significantly higher than that in healthy volunteers and IBS patients (43.4±14.1, 11.1±1.5, and 10.9±1.9 mm, respectively), and contraction ratio was significantly lower in CIPO patients than that in healthy volunteers and IBS patients (17.1±11.0%, 73.0±9.3%, and 74.6±9.4%, respectively). No significant differences were observed in the contraction cycle. This study is the first to assess the clinical utility of cine-MRI in CIPO patients. Cine-MRI clearly detected contractility impairments in CIPO patients. Cine-MRI is noninvasive, radiation-free, and can directly evaluate the entire small bowel peristalsis, and can detect the affected loops at a glance; therefore, it might be extremely useful for the diagnosis and follow-up of CIPO patients in clinical practice.

  14. Caries status in young Colombian children expressed by the ICCMS™ visual/radiographic combined caries staging system

    DEFF Research Database (Denmark)

    Cortes, Andrea; Ekstrand, Kim Rud; Gamboa, Luis Fernando

    2017-01-01

    OBJECTIVE: To report (1) the caries experience prevalence and mean, and the caries severity and distribution patterns, expressed clinically and combined with radiographs with the conventional and ICCMS™ systems in young children from Bogotá, Colombia; (2) the contribution of including radiographs...... to the clinical caries scoring and (3) in which surfaces the radiograph adds to the clinical caries registration. MATERIAL AND METHODS: Six hundred children from kindergartens/schools were enrolled: Cohort A: 2-year (n = 200), Cohort B: 4-year (n = 200) and Cohort C: 6-year (n = 200) olds. Radiographs were taken...... of the 4- and 6- year olds. Children were examined clinically using the Clinical (C) and Radiographic (R) ICCMS™-epi Caries Scoring Systems, staging caries lesions (d) as: Initial (Cepi/RA), Moderate (CM/RB) or Extensive (CE/RC). Caries experience including missing (m) and filled (f) surfaces was expressed...

  15. Cine magnetic resonance imaging, computed tomography and ultrasonography in the evaluation of chest wall invasion of lung cancer

    International Nuclear Information System (INIS)

    Yokozaki, Michiya; Nawano, Shigeru; Nagai, Kanji; Moriyama, Noriyuki; Kodama, Tetsuro; Nishiwaki, Yutaka.

    1997-01-01

    To assess the usefulness of cine-magnetic resonance imaging (cine-MRI) in the evaluation of chest wall invasion, we compared the results of cine-MRI with those of computed tomography (CT) and ultrasonography (US). Eleven patients were examined who had no pain and who were difficult to diagnose by routine examinations. MRI was performed with a Magnetom SP/4000, 1.5T unit (Siemens, Germany). For cine imaging, continuous turbo-FLUSH (ultra fast low angle shot) images were obtained at an orthogonal section to the chest wall during slow deep breathing. A CT scan was performed using a TCT 900S or Super Helix (Toshiba, Japan) at 1 cm intervals, with section thicknesses of 1 cm throughout the entire chest. US was performed with a model SSA-270A (Toshiba, Japan) with 7.5-MHz linear array scanners (PLF-705S; Toshiba, Japan). Sensitivity, specificity and accuracy were 67%, 75% and 73% for cine MRI, 67%, 63% and 64% for CT, 33%, 75% and 64% for US, respectively. These results indicate that cine MRI is potentially useful for the diagnosis of chest wall invasion of lung cancer. (author)

  16. Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2017-09-25

    Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm 3 ) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; Pcine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (Pcine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.

  17. Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform

    Science.gov (United States)

    Cai, Jing; Wang, Ziheng; Yin, Fang-Fang

    2011-01-01

    The objective of this study is to investigate accuracy of motion tracking of cine magnetic resonance imaging (MRI) for image-guided stereotactic body radiotherapy. A phantom platform was developed in this work to fulfill the goal. The motion phantom consisted of a platform, a solid thread, a motor and a control system that can simulate motion in various modes. To validate its reproducibility, the phantom platform was setup three times and imaged with fluoroscopy using an electronic portal imaging device (EPID) for the same motion profile. After the validation test, the phantom platform was evaluated using cine MRI at 2.5 frames/second on a 1.5T GE scanner using five different artificial profiles and five patient profiles. The above profiles were again measured with EPID fluoroscopy and used as references. Discrepancies between measured profiles from cine MRI and EPID were quantified using root-mean-square (RMS) and standard deviation (SD). Pearson’s product moment correlational analysis was used to test correlation. The standard deviation for the reproducibility test was 0.28 mm. The discrepancies (RMS) between all profiles measured by cine MRI and EPID fluoroscopy ranged from 0.30 to 0.49 mm for artificial profiles and ranged from 0.75 to 0.91 mm for five patient profiles. The cine MRI sequence could precisely track phantom motion and the proposed motion phantom was feasible to evaluate cine MRI accuracy. PMID:29296304

  18. Diagnostic accuracy of DXA compared to conventional spine radiographs for the detection of vertebral fractures in children.

    Science.gov (United States)

    Adiotomre, E; Summers, L; Allison, A; Walters, S J; Digby, M; Broadley, P; Lang, I; Morrison, G; Bishop, N; Arundel, P; Offiah, A C

    2017-05-01

    In children, radiography is performed to diagnose vertebral fractures and dual energy x-ray absorptiometry (DXA) to assess bone density. In adults, DXA assesses both. We aimed to establish whether DXA can replace spine radiographs in assessment of paediatric vertebral fractures. Prospectively, lateral spine radiographs and lateral spine DXA of 250 children performed on the same day were independently scored by three radiologists using the simplified algorithm-based qualitative technique and blinded to results of the other modality. Consensus radiograph read and second read of 100 random images were performed. Diagnostic accuracy, inter/intraobserver and intermodality agreements, patient/carer experience and radiation dose were assessed. Average sensitivity and specificity (95 % confidence interval) in diagnosing one or more vertebral fractures requiring treatment was 70 % (58-82 %) and 97 % (94-100 %) respectively for DXA and 74 % (55-93 %) and 96 % (95-98 %) for radiographs. Fleiss' kappa for interobserver and average kappa for intraobserver reliability were 0.371 and 0.631 respectively for DXA and 0.418 and 0.621 for radiographs. Average effective dose was 41.9 μSv for DXA and 232.7 μSv for radiographs. Image quality was similar. Given comparable image quality and non-inferior diagnostic accuracy, lateral spine DXA should replace conventional radiographs for assessment of vertebral fractures in children. • Vertebral fracture diagnostic accuracy of lateral spine DXA is non-inferior to radiographs. • The rate of unreadable vertebrae for DXA is lower than for radiographs. • Effective dose of DXA is significantly lower than radiographs. • Children prefer DXA to radiographs. • Given the above, DXA should replace radiographs for paediatric vertebral fracture assessment.

  19. Formative feedback in the clinical practice setting: What are the perceptions of student radiographers?

    International Nuclear Information System (INIS)

    Fowler, P.; Wilford, B.

    2016-01-01

    The role of feedback to a learner's development has been well established. There is an absence of studies relating to student radiographers experience of gaining and applying formative feedback. This study investigated processes involved in gaining written formative feedback in the clinical practice setting as well as the impact feedback had on student radiographers learning. The data was collected from radiography students at two higher education institutions by electronic questionnaire comprising scaled and open questions. There was a response rate of 37% (n = 103/279). Scaled data was analysed using inferential statistics and the qualitative data helped explain the findings. The majority of students recognised radiographers were frequently busy; resulting in feedback that is generic and not always timely. There is strength of opinion 82.6% (n = 85/103) that student radiographers do not work with any one radiographer consistently enough to enable the provision of constructive and meaningful feedback. There appears to be difficulty in obtaining the comments but the evidence shows they are valued. The majority of students seek feedback that is specific and will clearly identify areas for development. They reflect on feedback as well as use self-criticism of their practice performance indicating the development of autonomous skills. The challenge of enabling consistent one to one working with radiographers, the need to maximise a learning culture within practice environments and ensuring full engagement by radiographers and students could be addressed by modification of the feedback system, a working group being formed from students, supervising radiographers and academic tutors. - Highlights: • Students value constructive criticism and on-going verbal feedback. • Written feedback is not always easy to obtain because of pressures on staff time. • Student radiographers are rarely able to work consistently with the same person. • Student and mentor

  20. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  1. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  2. Modified Newman and Friedman Extraoral Radiographic Technique

    OpenAIRE

    Saberi, Eshagali; Hafezi, Ladan; Farhadmolashahi, Narges; Mokhtari, Manoochehr

    2012-01-01

    Introduction Good radiographs are required for endodontic therapy and because some patient’s are intolerant to intraoral films and/or sensors, this can cause complications in endodontic treatment. Extraoral film placement can be used to obtain clinically diagnostic and working radiographs. Materials and Methods The no. 2 receptor was placed against the model’s cheek and centered in the molar-premolar area. The central beam was directed toward this area from the opposite side. The vertical and...

  3. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  4. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  5. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  6. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  7. An Algorithm for Data Hiding in Radiographic Images and ePHI/R Application

    Directory of Open Access Journals (Sweden)

    Aqsa Rashid

    2018-01-01

    Full Text Available Telemedicine is the use of Information and Communication Technology (ICT for clinical health care from a distance. The exchange of radiographic images and electronic patient health information/records (ePHI/R for diagnostic purposes has the risk of confidentiality, ownership identity, and authenticity. In this paper, a data hiding technique for ePHI/R is proposed. The color information in the cover image is used for key generation, and stego-images are produced with ideal case. As a result, the whole stego-system is perfectly secure. This method includes the features of watermarking and steganography techniques. The method is applied to radiographic images. For the radiographic images, this method resembles watermarking, which is an ePHI/R data system. Experiments show promising results for the application of this method to radiographic images in ePHI/R for both transmission and storage purpose.

  8. Entrevista a Nemesio Juárez: “en el cine revolucionario el héroe es el hombre común”

    Directory of Open Access Journals (Sweden)

    Ana Clara Tosi

    2015-09-01

    Full Text Available El cine y las declaraciones de Nemesio Juárez, presentan las particularidades de la producción cinematográfica de América Latina, de los años 60 y 70, cine comprometido y revolucionario. Nemesio, participó del Grupo de Cine Liberación que integraban Fernando “Pino” Solanas, Octavio Getino y Gerardo Vallejo; y fue uno de los realizadores que puso el cine al servicio de una organización sindical.

  9. PA/Lateral chest X-ray is equivalent to cine-fluoroscopy for the detection of conductor externalization in defibrillation leads.

    Science.gov (United States)

    Steinberg, Christian; Sarrazin, Jean-François; Philippon, François; Champagne, Jean; Molin, Franck; Nault, Isabelle; Blier, Louis; Bouchard, Marc-André; Arsenault, Jean; O'Hara, Gilles

    2015-01-01

    Riata™ and Riata ST defibrillation leads (St. Jude Medical, Sylmar, CA, USA) are susceptible to insulation defects with conductor externalization. Cine-fluoroscopy is considered to be the gold standard for the documentation of insulation defects, but similar detection rates have been reported for posterior-anterior (PA)/lateral chest x-ray (CXR) with zooming. Prospective single-center study to assess the diagnostic equivalence of a PA/lateral CXR with zooming for the detection of Riata insulation defects in a direct comparison to cine-fluoroscopy. Seventy-eight consecutive patients underwent 3-view cine-fluoroscopy and a PA/lateral CXR. All CXRs and cine-fluoroscopy images were reviewed by blinded electrophysiologists and staff radiologists. Forty-four of 78 patients had an abnormal cine-fluoroscopy (56%). The diagnostic correlation between PA/lateral CXR and cine-fluoroscopy was excellent (κ = 0.90; 95% confidence interval 0.80-1.00). PA/lateral CXR was equivalent to cine-fluoroscopy for the detection of conductor externalization showing a sensitivity of 97.7% and a specificity of 91.2%. The mean radiation effective dose of CXR was significantly lower compared to cine-fluoroscopy (0.09 millisievert [mSV] vs 0.85 ± 0.47 mSv; P cine-fluoroscopy for the detection of Riata insulation defects and should be considered as the preferred screening method. ©2014 Wiley Periodicals, Inc.

  10. Advanced practice for therapy radiographers - A discussion paper

    International Nuclear Information System (INIS)

    Eddy, Angela

    2008-01-01

    Purpose: The purpose of this discussion paper is to explore issues related to advanced practice for therapy radiographers. Key themes: The paper will focus on key themes that have impacted on advanced practice for therapy radiographers such as government initiatives and policy, confounding terminology associated with advanced practice such as role extension, role expansion, role development, and expert practice. The theory and development of expert practice is explored and paralleled to existing roles in therapy using the Benner model to define stages of professional development and competence. Evidence for advanced practice, and education and training will also be explored. All of these issues will be considered within the perspective of the current clinical and political environment that therapy radiographers operate in. Conclusions: The application of advanced practice can and should incorporate elements of role extension and role development, with some tangible skills ladder to guide and shape the development of potential consultant practitioners. There is a need to identify the current position of advanced practice nationally, and to monitor existing and emerging roles, possibly though a longitudinal study. The skill mix as a whole within departments need to be part of an ongoing evaluation with close collaboration between the professional body, departmental managers and higher education institutes to develop curricula to support existing and emerging roles. There are also key lessons to be learned from other professions with more experience with advanced practitioners if recruitment and retention is not going to continue to be a problem

  11. 10 CFR 34.46 - Supervision of radiographers' assistants.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Supervision of radiographers' assistants. 34.46 Section 34... REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.46 Supervision of... personal supervision of a radiographer. The personal supervision must include: (a) The radiographer's...

  12. El fomento del cine europeo y su comercialización. Estudio comparado de los cines español y francés

    Directory of Open Access Journals (Sweden)

    Jéssica Izquierdo Castillo

    2011-12-01

    Full Text Available El ámbito cinematográfico es tradicionalmente el que mayor dificultades presenta en su desarrollo dentro del audiovisual europeo. Este artículo estudia las fuentes de financiación recibidas por el cine en forma de políticas de fomento y promoción, tomando como referencia los sectores francés y español. El artículo se divide en tres apartados. En primer lugar, se analiza la estructura de sectores básica que componen cada una de las cinematografías, a partir de un estudio comparado de la producción, distribución y exhibición. En segundo lugar, se ofrece una panorámica sobre las medidas de fomento aplicadas en las respectivas industrias, con el fin de detctar las deficiencias más significativas que presentan frente a la hegemonía cinematográfica estadounidense. En tercer lugar, se obtienen las tendencias comerciales que desarrollan el cine español y francés a partir de la aplicación de las medidas de fomento para enfrentarse a la superioridad mercantil del cine americano.Los resultados sugieren que las pirncipales diferentes entre ambas cinematografías, a pesar de los resulados franceses claramente postivos, no radica tanto en las películas que producen, sino en la aplicación de las políticas de comunicación. Esto genera unas consecuencias en términos comerciales que repercute en la viabilidad económica de cada una de estas cinematografías europeas.

  13. TH-A-BRF-04: Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kleijnen, J; Asselen, B; Burbach, M; Intven, M; Reerink, O; Philippens, M; Lagendijk, J; Raaymakers, B [University Medical Center Utrecht, Utrecht (Netherlands)

    2014-06-15

    Purpose: To investigate the intra-fraction motion in patients with early stage rectal cancer using cine-MRI. Methods: Sixteen patient diagnosed with early stage rectal cancer underwent 1.5 T MR imaging prior to each treatment fraction of their short course radiotherapy (n=76). During each scan session, three 2D sagittal cine-MRIs were performed: at the beginning (Start), after 9:30 minutes (Mid), and after 18 minutes (End). Each cine-MRI has a duration of one minute at 2Hz temporal resolution, resulting in a total of 3:48 hours of cine-MRI. Additionally, standard T2-weighted (T2w) imaging was performed. Clinical target volume (CTV) an tumor (GTV) were delineated on the T2w scan and transferred to the first time-point of each cine-MRI scan. Within each cine-MRI, the first frame was registered to the remaining frames of the scan, using a non-rigid B-spline registration. To investigate potential drifts, a similar registration was performed between the first frame of the Start and End scans.To evaluate the motion, the distances by which the edge pixels of the delineations move in anterior-posterior (AP) and cranial-caudal (CC) direction, were determined using the deformation field of the registrations. The distance which incorporated 95% of these edge pixels (dist95%) was determined within each cine-MRI, and between Start- End scans, respectively. Results: Within a cine-MRI, we observed an average dist95% for the CTV of 1.3mm/1.5mm (SD=0.7mm/0.6mm) and for the GTV of 1.2mm/1.5mm (SD=0.8mm/0.9mm), in respectively AP/CC. For the CTV motion between the Start and End scan, an average dist95% of 5.5mm/5.3mm (SD=3.1mm/2.5mm) was found, in respectively AP/CC. For the GTV motion, an average dist95% of 3.6mm/3.9mm (SD=2.2mm/2.5mm) was found in AP/CC, respectively. Conclusion: Although intra-fraction motion within a one minute cine-MRI is limited, substantial intra-fraction motion was observed within the 18 minute time period between the Start and End cine-MRI.

  14. TH-A-BRF-04: Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI

    International Nuclear Information System (INIS)

    Kleijnen, J; Asselen, B; Burbach, M; Intven, M; Reerink, O; Philippens, M; Lagendijk, J; Raaymakers, B

    2014-01-01

    Purpose: To investigate the intra-fraction motion in patients with early stage rectal cancer using cine-MRI. Methods: Sixteen patient diagnosed with early stage rectal cancer underwent 1.5 T MR imaging prior to each treatment fraction of their short course radiotherapy (n=76). During each scan session, three 2D sagittal cine-MRIs were performed: at the beginning (Start), after 9:30 minutes (Mid), and after 18 minutes (End). Each cine-MRI has a duration of one minute at 2Hz temporal resolution, resulting in a total of 3:48 hours of cine-MRI. Additionally, standard T2-weighted (T2w) imaging was performed. Clinical target volume (CTV) an tumor (GTV) were delineated on the T2w scan and transferred to the first time-point of each cine-MRI scan. Within each cine-MRI, the first frame was registered to the remaining frames of the scan, using a non-rigid B-spline registration. To investigate potential drifts, a similar registration was performed between the first frame of the Start and End scans.To evaluate the motion, the distances by which the edge pixels of the delineations move in anterior-posterior (AP) and cranial-caudal (CC) direction, were determined using the deformation field of the registrations. The distance which incorporated 95% of these edge pixels (dist95%) was determined within each cine-MRI, and between Start- End scans, respectively. Results: Within a cine-MRI, we observed an average dist95% for the CTV of 1.3mm/1.5mm (SD=0.7mm/0.6mm) and for the GTV of 1.2mm/1.5mm (SD=0.8mm/0.9mm), in respectively AP/CC. For the CTV motion between the Start and End scan, an average dist95% of 5.5mm/5.3mm (SD=3.1mm/2.5mm) was found, in respectively AP/CC. For the GTV motion, an average dist95% of 3.6mm/3.9mm (SD=2.2mm/2.5mm) was found in AP/CC, respectively. Conclusion: Although intra-fraction motion within a one minute cine-MRI is limited, substantial intra-fraction motion was observed within the 18 minute time period between the Start and End cine-MRI

  15. The Radiographer's multidisciplinary team role in theatre scenarios

    International Nuclear Information System (INIS)

    Williams, H.; Widdowfield, M.; Cosson, P.

    2015-01-01

    Background: Radiographers work in multidisciplinary teams (MDTs) to image intra-operatively using ionising radiation. The radiographer is responsible according to IR(ME)ER (2000) and IRR(99) regulations for advocating patient and theatre personnel safety. A comprehensive literature search revealed limited studies analysing the radiographer's experiences of utilising power to influence MDTs. Therefore the aim of the study was to explore the power relationships within different MDT scenarios. Method: A qualitative approach was adopted consisting of interviews exploring radiographers' experiences as 1) established Cardiology team members and 2) transient members of Orthopaedic teams. French and Raven's power bases were used as an a priori framework. Ethical approval was obtained prior to commencement. Sampling was purposive, following gatekeeper permission, and subsequent participation was voluntary. Thematic content analysis was undertaken following data collection. Findings and discussion: Perpetration of Legitimate Power was more frequently attempted in transient teams. However, there were more successful descriptions in established teams. Expert Power was reciprocated successfully in established teams but was context dependent in transient teams. Referent power was well used by participants, although the transient nature of teams did affect this. Job satisfaction was expressed by both groups, although evidence presented was more comprehensive in established teams. Conclusion: The social bases of power at play within two MDTs have been examined. It is unclear to what extent the team specialism has a role in the differences identified. Radiographers working in established teams may have greater job satisfaction and perpetrate power bases more effectively than radiographers serving in transient teams. - Highlights: • This is a qualitative study using a phenomenological approach. • The social bases of power are adopted as an a priori theoretical

  16. CRIMINOLOGÍA DEL CINE Las causas del crimen en el cine mexicano de la «Época de Oro»

    OpenAIRE

    Álvaro Arturo Fernández Reyes

    2005-01-01

    Considerando el cine criminal como una autoridad cultural que otorga en su representación ideológica una explicación popular de las causas del crimen, se analiza, desde el ángulo criminológico, desde el punto de vista de los cineastas mexicanos y en una muestra representativa de los años cuarenta y cincuenta, los motivos que llevan a los personajes de luz y sombra a delinquir. De lo anterior resultan tres posturas teóricas que rigen las explicaciones: el mal genético, ya com...

  17. Estructura de las relaciones públicas y el protocolo en el cine, eventos internacionales : el caso del Sevilla Festival de Cine Europeo

    OpenAIRE

    Pulido Polo, Marta; Alfaro Lara, Mª Auxiliadora

    2005-01-01

    En un contexto globalizado y multicultural como el actual, cada vez más los profesionales de las relaciones públicas trabajan al servicio de instituciones, organismos u empresas que se comunican con sus públicos a través de numerosas manifestaciones culturales, tales como la danza, la música, la pintura,... El cine 1 es una de ellas y su potencial comunicador se multiplica aún más en los eventos de carácter internacional como los festivales, a través de los cuales los pueblo...

  18. Retreatment or radiographic monitoring in endodontics.

    Science.gov (United States)

    Van Nieuwenhuysen, J P; Aouar, M; D'Hoore, W

    1994-03-01

    The aim of this clinical study was to assess 1032 endodontically treated roots in relation to: (i) the success rate of retreatment (612 roots)--only cases that had recall examinations of 6 months or longer were evaluated; (ii) the influence of various factors on the technical and clinical results of the retreatment; and (iii) the consequences of radiographic monitoring of 420 asymptomatic roots when the root filling was radiographically deficient (short, overextended and/or permeable root fillings). Technical assessment of the retreatment showed that the root was adequately sealed in 52.3% of cases, the root filling was improved in 33.8%, was identical with the initial treatment in 11.1% and was worse than the first treatment in 2.8% of the canals. Clinical assessment of the retreatment of symptomatic roots showed that 71.8% of the retreatments were judged successful, 18.9% showed some healing and 9.3% had failed. The initial size of the periapical lesion, the use of rubber dam, the root filling technique and the apical level of the root filling had a statistically significant influence on the result of the retreatment. Monitoring radiographically (median time span 6 years) led to maintenance of the status quo in 94.8% of cases, healing in 2.4% and failure in 2.8% of the canals. Retreatment is clearly indicated when periapical radiolucency, clinical signs and/or symptoms are present with relative success of up to 91%. When no or little radiographic evidence of periapical pathology was present, when clinical signs and symptoms were absent or when the root filling was radiographically deficient, radiographic monitoring led to complications in only a limited number of cases. clinical decision, endodontic retreatment, radiographic evaluation.

  19. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  20. El Cine, recurso didáctico para la educación en Historia

    OpenAIRE

    Núñez, José

    2012-01-01

    El presente trabajo tratará de mostrar la importancia del cine como instrumento válido de educación en Historia para alumnos de la ESO, ya sea por su innegable faceta de “contador de historias” como por el poder de sus imágenes y la demostrada influencia que éstas ejercen sobre los jóvenes de hoy en día. A través del estudio de diferentes autores con respecto la relación existente entre cine y educación trataremos de explicar como en nuestra función de profesores podríamos operar con una s...

  1. Masculinidad y violencia en el nuevo cine mexicano. Las películas de Luis Estrada

    Directory of Open Access Journals (Sweden)

    Claudia Elizabeth Puente

    2016-01-01

    Full Text Available En este artículo exploraremos la conformación de las masculinidades a través de las representaciones cinematográficas en América latina, específicamente en la obra del mexicano Luis Estrada, parte fundamental del llamado Nuevo cine mexicano en sus obras exhibidas entre 1999 y 2010. Aunque el universo de estudios de masculinidades es cada vez más amplio, las representaciones cinematográficas no han sidomuy exploradas. Este artículo pretende hacer un análisis de las representaciones masculinas y su relación con las representaciones femeninas en el nuevo cine mexicano en un contexto de violencia desde una perspectiva crítica feminista.

  2. Representaciones de la otredad en el cine argentino contemporáneo

    Directory of Open Access Journals (Sweden)

    Alfredo Dillon

    2016-03-01

    Full Text Available Este trabajo analiza los modos de representación de la otredad en tres películas del cine argentino contemporáneo: Bolivia (2001, Cama adentro (2004 y El hombre de al lado (2009. En las tres obras se problematiza la relación con la diferencia a partir de la presencia de personajes “otros” que encarnan formas de vida diversas: un inmigrante, una mucama y un vecino, respectivamente. Cada película propone, a su vez, una manera distinta de resolver la relación con la alteridad: desde la eliminación del otro hasta la conciliación, el cine ofrece un abanico de respuestas imaginarias para esta encrucijada social.

  3. Nonrigid motion compensation in compressed sensing reconstruction of cardiac cine MRI.

    Science.gov (United States)

    Tolouee, Azar; Alirezaie, Javad; Babyn, Paul

    2018-02-01

    In this work, a robust nonrigid motion compensation approach, is applied to the compressed sensing reconstruction of dynamic cardiac cine MRI sequences. Respiratory and cardiac motion separation coupled with a registration algorithm is used to provide accurate reconstruction of dynamic cardiac images. The proposed scheme employs a variable splitting based optimization strategy to enable joint motion estimation along with reconstruction. We define the recovery as an energy minimization scheme utilizing an objective function that combines data consistency, spatial smoothness, and motion penalties. The validation of the proposed algorithm using numerical phantom and in-vivo cine MRI data demonstrates reconstruction of cardiac MRI data with less spatio-temporal blurring and motion artifacts from extensively under-sampled data. The proposed method is observed to provide improved reconstructions over state-of-the-art motion compensation schemes. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning

    International Nuclear Information System (INIS)

    Dowling, J; Chandra, S; Dang, K; Fox, Chris D; Gill, Suki; Kron, T; Pham, D; Foroudi, F

    2014-01-01

    The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.

  5. La representación de las personas con discapacidad visual en el cine

    Directory of Open Access Journals (Sweden)

    Marta BADIA CORBELLA

    2016-11-01

    Full Text Available Este artículo pretende ser una aproximación sobre cómo el cine ha abordado la realidad de las personas con discapacidad visual. Más concretamente, trata de analizar cuáles han sido las descripciones habituales que se han realizado de las personas ciegas en las películas y cuáles son los estereotipos identificados que las representan. Para ello se han analizado 12 películas, producidas entre 1962 y 2009, que tienen entre sus personajes a personas con discapacidad visual. Aunque en el cine se han producido avances en disipar estereotipos sobre la imagen de la persona con ceguera, todavía en la filmografía se siguen perpetuando representaciones que poco tienen que ver con la realidad de las personas con discapacidad visual.

  6. Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning

    Science.gov (United States)

    Dowling, J.; Dang, K.; Fox, Chris D.; Chandra, S.; Gill, Suki; Kron, T.; Pham, D.; Foroudi, F.

    2014-03-01

    The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, pmanual verification.

  7. Claves del éxito del personaje psicópata como protagonista en el cine

    OpenAIRE

    Visa Barbosa, Mariona

    2011-01-01

    El presente artículo constituye una investigación sobre los personajes de perfil psicópata proliferan en el cine desde hace muchos años. En el presente artículo la intención es realizar una aproximamos a las causas que provocan el éxito de este tipo de películas en la sociedad. Por una parte, se define el carácter psicópata y se exponen algunos ejemplos actuales tanto de la realidad cómo del cine. Finalmente, se analizan los elementos cinematográficos más comunes en las películ...

  8. LA MUSICA EN EL CINE BELICO: EL SONIDO DE LA GUERRA

    OpenAIRE

    Pachon, Alejandro

    2015-01-01

    Las categorías de la música fílmica han estado lo bastante encasilladas en el pasado reciente como para hacer patente que la categoría comercial y producida bajo el concepto cine bélico hace alusión a películas sobre conflictos bélicos del siglo XX, especialmente las dos guerras mundiales, cuya acción básica sea la propia guerra.

  9. Motion compensated cine CMR of the fetal heart using radial undersampling and compressed sensing.

    Science.gov (United States)

    Roy, Christopher W; Seed, Mike; Kingdom, John C; Macgowan, Christopher K

    2017-03-20

    To develop and evaluate a reconstruction framework for high resolution time-resolved CMR of the fetal heart in the presence of motion. Data were acquired using a golden angle radial trajectory in seven fetal subjects and reconstructed as real-time images to detect fetal movement. Data acquired during through-plane motion were discarded whereas in-plane motion was corrected. A fetal cardiac gating signal was extracted to sort the corrected data by cardiac phase, allowing reconstruction of cine images. The quality of motion corrected images and the effect of data undersampling were quantified using separate expressions for spatial blur and image error. Motion corrected reordered cine reconstructions (127 slices) showed improved image quality relative to both uncorrected cines and corresponding real-time images across a range of root-mean-squared (RMS) displacements (0.3-3.7 mm) and fetal heart rates (119-176 bpm). The relative spatial blur between cines with and without motion correction increased with in-plane RMS displacement leading to an effective decrease in the effective spatial resolution for images without motion correction. Image error between undersampled and reference images was less than 10% for reconstructions using 750 or more spokes, yielding a minimum acceptable scan time of approximately 4 s/slice during quiescent through plane motion. By rejecting data corrupted by through-plane motion, and correcting data corrupted by in-plane translation, the proposed reconstruction framework accounts for common sources of motion artifact (gross fetal movement, maternal respiration, fetal cardiac contraction) to produce high quality images of the fetal heart.

  10. Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

    Science.gov (United States)

    Bonanno, Gabriele; Hays, Allison G; Weiss, Robert G; Schär, Michael

    2018-08-01

    Depressed coronary endothelial function (CEF) is a marker for atherosclerotic disease, an independent predictor of cardiovascular events, and can be quantified non-invasively with ECG-triggered spiral cine MRI combined with isometric handgrip exercise (IHE). However, MRI-CEF measures can be hindered by faulty ECG-triggering, leading to prolonged breath-holds and degraded image quality. Here, a self-gated golden angle spiral method (SG-GA) is proposed to eliminate the need for ECG during cine MRI. SG-GA was tested against retrospectively ECG-gated golden angle spiral MRI (ECG-GA) and gold-standard ECG-triggered spiral cine MRI (ECG-STD) in 10 healthy volunteers. CEF data were obtained from cross-sectional images of the proximal right and left coronary arteries in a 3T scanner. Self-gating heart rates were compared to those from simultaneous ECG-gating. Coronary vessel sharpness and cross-sectional area (CSA) change with IHE were compared among the 3 methods. Self-gating precision, accuracy, and correlation-coefficient were 7.7 ± 0.5 ms, 9.1 ± 0.7 ms, and 0.93 ± 0.01, respectively (mean ± standard error). Vessel sharpness by SG-GA was equal or higher than ECG-STD (rest: 63.0 ± 1.7% vs. 61.3 ± 1.3%; exercise: 62.6 ± 1.3% vs. 56.7 ± 1.6%, P cine MRI method even when ECG is faulty or not available. Magn Reson Med 80:560-570, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

    Science.gov (United States)

    Usman, M; Ruijsink, B; Nazir, M S; Cruz, G; Prieto, C

    2017-05-01

    To present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI. 3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4-5min and 4D whole-heart volumes (3D+cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction. For data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P>0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition. The proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5min free breathing acquisition. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Quantification of mechanical ventricular dyssynchrony. Direct comparison of velocity-encoded and cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Muellerleile, K.; Baholli, L.; Groth, M.

    2011-01-01

    Purpose: The preoperative assessment of mechanical dyssynchrony can help to improve patient selection in candidates for cardiac resynchronization therapy (CRT). The present study compared the performance of velocity-encoded (VENC) MRI to cine-magnetic resonance imaging (MRI) for quantifying mechanical ventricular dyssynchrony. Materials and Methods: VENC-MRI and cine-MRI were performed in 20 patients with heart failure NYHA class III and reduced ejection fraction (median: 24 %, interquartile range: 18 - 28 %) before CRT device implantation. The interventricular mechanical delay (IVMD) was assessed by VENC-MRI as the temporal difference between the onset of aortic and pulmonary flow. Intraventricular dyssynchrony was quantified by cine-MRI, using the standard deviation of time to maximal wall thickening in sixteen left ventricular segments (SDt-16). The response to CRT was assessed in a six-month follow-up. Results: 14 patients (70 %) clinically responded to CRT. A similar accuracy was found to predict the response to CRT by measurements of the IVMD and SDt-16 (75 vs. 70 %; p = ns). The time needed for data analysis was significantly shorter for the IVMD at 1.69 min (interquartile range: 1.66 - 1.88 min) compared to 9.63 min (interquartile range: 8.92 - 11.63 min) for the SDt-16 (p < 0.0001). Conclusion: Measurements of the IVMD by VENC-MRI and the SDt-16 by cine-MRI provide a similar accuracy to identify clinical responders to CRT. However, data analysis of the IVMD is significantly less time-consuming compared to data analysis of the SDt-16. (orig.)

  13. Treatment and diagnosis of middle fossa arachnoid cyst. Ventriculofiberscopy and cine-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kamikawa, Shuji; Kuwamura, Keiichi [Hyogo Prefectural Awaji Hospital, Sumoto (Japan); Tamaki, Norihiko

    1998-07-01

    The treatment of intracranial arachnoid cysts is controversial regarding its surgical indication and operative procedures. Conventional surgical approaches such as fenestration, membranectomy, and shunting operation are invasive. Also CT cisternography and/or RI cisternography are invasive, when it has been performed to evaluate the possible CSF communications between the arachnoid cyst and subarachnoid space. Between July 1994 and February 1997, 10 patients with intracranial middle fossa arachnoid cysts were treated with a newly developed ventriculofiberscope which is characterized by splendid mechanical flexibility and high resolution. The cine-MRI, which is a non-invasive diagnostic tool, is used to evaluate the CSF circulation around the cyst fenestration. The patients` ages ranged from 4 months to 10 years, with a mean of 4.46 years. The cyst locations were left middle fossa (9), and right (1). Eight patients presented with macrocrania, 4 with developmental delay, three with seizure, two with headache, and one with subdural hematoma. The patients were preoperatively evaluated by means of MRI and cine-MR images. In all patients ventriculofiberscopic procedures including cyst fenestration, membranous dissection, cyst puncture and shriveling were successfully performed. Postoperative MR and cine-MR studies have shown reduction of the cyst size and appropriate CSF circulation. Neuroendoscopic procedures seem to be the first choice for children with arachnoid cysts and the ventriculofiberscope proved to be very useful not only for cyst fenestration but also for cyst dissection. In addition, the non-invasive cine-MR studies are useful for long follow-up at OPD. (author)

  14. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  15. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T

    International Nuclear Information System (INIS)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L.; Nikolaou, Konstantin; Reiser, Maximilian F.

    2015-01-01

    Highlights: • Grappa-based real time cine cardiac MRI is feasible for assessment of left ventricular function. • Significant underestimation of systolic function, peak ejection and filling rates needs to be considered. • Heart rate is the only positive predictor of the deviation of obtained parameters. - Abstract: Objectives: To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3 T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. Materials and methods: In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Results: Among 25 subjects, 24 were included in the analysis (mean age: 50.5 ± 21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC < 0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2 ± 178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p < 0.05). Conclusions: RT cine MRI at 3 T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates

  16. Stress cine MRI for detection of coronary artery disease; Stress-Cine-MRT zur Primaeridagnostik der koronaren Herzkrankheit

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Hofer, U.; Schild, H. [Bonn Univ. (Germany). Radiologische Klinik; Omran, H. [Medizinische Universitaetsklinik II Bonn (Germany)

    2002-05-01

    mainly be explained by the better image quality with sharp delineation of the endocardial and epicardial borders. Currently, stress MRI is already a realistic clinical alternative for the non-invasive assessment of CAD in patients with impaired image quality in echocardiography. (orig.) [German] Belastungsuntersuchungen sind einer der wesentlichen Pfeiler der nicht-invasiven Diagnostik der koronaren Herzkrankheit (KHK). Die Stress-Cine-Magnetresonanztomographie (Stress-MRT) beruht wie die Stressechokardiographie auf dem direkten Nachweis ischaemieinduzierter Wandbewegungsstoerungen. Ihr Einsatz bei kardialen Belastungsuntersuchungen wurde bisher vor allem durch die langen Untersuchungszeiten und die limitierten Ueberwachungsmoeglichkeiten der Patienten eingeschraenkt. Erst seit kurzem wurden durch technische Weiterentwicklungen (insbesondere ultraschnelle k-Raum-segmentierte Sequenzen) die wesentlichen Rahmenbedingungen fuer eine klinisch praktikable kardiale MRT-Belastungsdiagnostik geschaffen. Als Stress-Induktoren koennen physikalische (Fahrradergometrie) und pharmakologische Belastungsverfahren ({beta}{sub 1}-Mimetika [Dobutamin] oder Vasodilatatoren [Dipyridamol, Adenosin]) eingesetzt werden. Insbesondere seit der Etablierung von Hochdosis-Protokollen mit fakultativer Atropingabe wird die Belastung mit Dobutamin bei der Stress-MRT zum Nachweis einer KHK (Sensitivitaet: 83 - 87%; Spezifitaet: 83 - 86%) von den meisten Arbeitsgruppen favorisiert. Schwerere Komplikationen treten in 0,25% der Faelle auf. Im direkten Vergleich zeigte sich die Dobutamin-Stress-MRT aufgrund der besseren Bildqualitaet der Dobutamin-Stressechokardiographie ueberlegen (Sensitivitaet: 86,2% vs. 74,3%, p < 0,05; Spezifitaet: 85,7% vs. 69,8%, p < 0,05). Die Stress-MRT ist bereits zum jetzigen Zeitpunkt eine realistische - in der Routinediagnostik anwendbare - Alternative zur Stressechokardiographie. Vom Einsatz der Stress-MRT profitieren zur Zeit v.a. Patienten, bei denen aufgrund grundsaetzlich

  17. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke (Toyama Medical and Pharmaceutical Univ. (Japan))

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  18. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke

    1993-01-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author)

  19. UN CINEASTA CHILENO. KUZMANICH Y EL CINE DE LA VIOLENCIA EN COLOMBIA

    Directory of Open Access Journals (Sweden)

    Angélica María Mateus Mora

    2007-07-01

    Full Text Available La autora presenta un análisis del film Canaguaro (1981 del chileno Dunav Kuzmanich.Se trata de una realización cinematográfica colombiana profundamenteinnovadora en su constitución, en cuanto desarrolla una construcción colectiva e imaginaria de la violencia. En este contexto de la violencia sociopolítica de la guerrilla, el protagonista no es necesariamente un personaje, sino que es el pueblo, algo que es interesante pues conecta el cine latinoamericano con una larga reflexión ensayística. Este film, muestra un cine que asume una posición crítica frente a la historia colombiana oficial, con la clara intención de develar episodios ocultos de esta historia, en especial de una etapa particular, donde el cine logra, incluso más que la misma historiografía, representar la complejidad histórica, analizar los procesos internos y proyectar esa realidad histórica al presente.

  20. La mujer española y el cine español

    Directory of Open Access Journals (Sweden)

    Dolores Barbazán Capeáns

    2010-01-01

    Full Text Available El cine es un elemento motivador para el aprendizaje de español como lengua extranjera, así como un recurso didáctico esencial (Romea 2003, Brandimonte 2003.Con el uso del cine en clase de lenguas se les introducen a los estudiantes contenidos culturales, sociales y económicos (Herrero 2008. El objetivo de este trabajo es la presentación de una unidad didáctica sobre las mujeres españolas y el cine español,dirigida a estudiantes chinos en un contexto de inmersión en Tarragona. Los estudiantes tienen un nivel B2 siguiendo el Marco Común Europeo de Referencia: enseñanza,aprendizaje y evaluación (MCER 2002. Se sigue un enfoque comunicativo por tareas.La duración de la unidad didáctica es de aproximadamente cuatro horas y media. Su aplicación en el aula ha resultado enriquecedora y contó con muy buena acogida por parte de los estudiantes.

  1. La mujer española y el cine español

    Directory of Open Access Journals (Sweden)

    Dolores Barbazán Capeáns

    2012-08-01

    Full Text Available El cine es un elemento motivador para el aprendizaje de español como lenguaextranjera, así como un recurso didáctico esencial (Romea 2003, Brandimonte 2003.Con el uso del cine en clase de lenguas se les introducen a los estudiantes contenidosculturales, sociales y económicos (Herrero 2008. El objetivo de este trabajo es lapresentación de una unidad didáctica sobre las mujeres españolas y el cine español,dirigida a estudiantes chinos en un contexto de inmersión en Tarragona. Los estudiantestienen un nivel B2 siguiendo el Marco Común Europeo de Referencia: enseñanza,aprendizaje y evaluación (MCER 2002. Se sigue un enfoque comunicativo por tareas.La duración de la unidad didáctica es de aproximadamente cuatro horas y media. Suaplicación en el aula ha resultado enriquecedora y contó con muy buena acogida porparte de los estudiantes.

  2. Normal nonuniformity of left ventricular contraction. Assessment by cine MR imaging with presaturation myocardial tagging

    International Nuclear Information System (INIS)

    Naito, H.; Arisawa, J.; Harada, K.; Yamagami, H.; Kozuka, T.; Tamura, S.

    1996-01-01

    Purpose: To identify the normal performance of left ventricular (LV) regional contraction using cine MR imaging with presaturation myocardial tagging. Material and Methods: Sixteen normal volunteers were examined on a 1.5 T MR system with tagging cine sequences. Tags were applied at end-diastole as 2 parallel black lines on short-axis and 4-chamber sections, and the fractional shortenings were calculated at 7 LV locations. Results: The following results were obtained with significance: A transmural gradient of contractility in the short-axis section; prolonged late-systolic endocardial shortening and epicardial early termination in the free wall; initial delay of shortening in the anterior wall; apical predominance of contractility; predominance of circumferential shortening in the free wall and of meridional shortening in the septum. These findings could be associated with myocardial fiber architecture, presumed wall stress and temporal asynergy of excitation. Conclusion: Cine MR imaging with myocardial tagging proved to be useful in assessing the nonuniformity of LV contraction. (orig.)

  3. Colon wall motility: comparison of novel quantitative semi-automatic measurements using cine MRI.

    Science.gov (United States)

    Hoad, C L; Menys, A; Garsed, K; Marciani, L; Hamy, V; Murray, K; Costigan, C; Atkinson, D; Major, G; Spiller, R C; Taylor, S A; Gowland, P A

    2016-03-01

    Recently, cine magnetic resonance imaging (MRI) has shown promise for visualizing movement of the colonic wall, although assessment of data has been subjective and observer dependent. This study aimed to develop an objective and semi-automatic imaging metric of ascending colonic wall movement, using image registration techniques. Cine balanced turbo field echo MRI images of ascending colonic motility were acquired over 2 min from 23 healthy volunteers (HVs) at baseline and following two different macrogol stimulus drinks (11 HVs drank 1 L and 12 HVs drank 2 L). Motility metrics derived from large scale geometric and small scale pixel movement parameters following image registration were developed using the post ingestion data and compared to observer grading of wall motion. Inter and intra-observer variability in the highest correlating metric was assessed using Bland-Altman analysis calculated from two separate observations on a subset of data. All the metrics tested showed significant correlation with the observer rating scores. Line analysis (LA) produced the highest correlation coefficient of 0.74 (95% CI: 0.55-0.86), p cine MRI registered data provides a quick, accurate and non-invasive method to detect wall motion within the ascending colon following a colonic stimulus in the form of a macrogol drink. © 2015 John Wiley & Sons Ltd.

  4. Cine, cárcel y mujeres: un ejemplo de creación de conocimiento

    Directory of Open Access Journals (Sweden)

    María del Carmen Pereira Domínguez

    2009-05-01

    Full Text Available El cine enriquece la percepción personal, desarrolla nuestra sensibilidad y nos acerca a esos otros mun-dos del interior, tan susceptibles de ser protegidos por su inestimable capacidad de hacernos crecer a golpes de iden-tidad. A esa identidad se llega por factores simbólicos y otros nada biológicos, que pueden condicionar la supremacíade un género, así como transformar viejos estereotipos sociales existentes. El cine es un elemento de masas de gran im-pacto y su valor tecnológico y didáctico como generación de conocimiento ya no se cuestiona. En este artículo se tratade mejorar los estilos de aprendizaje y de favorecer los conocimientos, destrezas y actitudes adecuadas en un grupode reclusas de cara a su reinserción social. Desde una metodología cualitativa de acción-investigación-acción, y deresolución de problemas, se desarrolló un programa de intervención pedagógica con el cine, hacia la creación de co-nocimiento,notables de este estudio.

  5. Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

    Science.gov (United States)

    Li, Shu; Chan, Cheong; Stockmann, Jason P; Tagare, Hemant; Adluru, Ganesh; Tam, Leo K; Galiana, Gigi; Constable, R Todd; Kozerke, Sebastian; Peters, Dana C

    2015-04-01

    To investigate algebraic reconstruction technique (ART) for parallel imaging reconstruction of radial data, applied to accelerated cardiac cine. A graphics processing unit (GPU)-accelerated ART reconstruction was implemented and applied to simulations, point spread functions and in 12 subjects imaged with radial cardiac cine acquisitions. Cine images were reconstructed with radial ART at multiple undersampling levels (192 Nr × Np  = 96 to 16). Images were qualitatively and quantitatively analyzed for sharpness and artifacts, and compared to filtered back-projection, and conjugate gradient SENSE. Radial ART provided reduced artifacts and mainly preserved spatial resolution, for both simulations and in vivo data. Artifacts were qualitatively and quantitatively less with ART than filtered back-projection using 48, 32, and 24 Np , although filtered back-projection provided quantitatively sharper images at undersampling levels of 48-24 Np (all P parallel radial MR imaging, providing reduced artifacts while mainly maintaining sharpness compared to filtered back-projection, as shown by its first application in cardiac studies. © 2014 Wiley Periodicals, Inc.

  6. Cine Computed Tomography Without Respiratory Surrogate in Planning Stereotactic Radiotherapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.; Johnson, Valen; Chi, Pai-Chun Melinda; Pan, Tinsu

    2009-01-01

    Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26 patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning

  7. Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function

    International Nuclear Information System (INIS)

    Sandner, Torleif A.; Huber, Armin M.; Theisen, Daniel; Reiser, Maximilian F.; Wintersperger, Bernd J.; Houck, Philip; Runge, Val M.; Sincleair, Spencer

    2008-01-01

    The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 x 1.9 mm 2 at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R=3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P=.79), ESV (2.2 ml; P=0.81), EF (-0.3%; P=0.95) and MM (2.4 g; P=0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P>0.7) nor for TSENSE data (all P>0.9). Multifactorial ANOVA showed non-significant differences (all P>0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time. (orig.)

  8. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  9. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  10. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  11. Review on radiographic inspection in 1982

    International Nuclear Information System (INIS)

    Maruyama, Yutaka

    1983-01-01

    This is a report of the activities in the radiographic inspection department of Japanese Society for Non-destructive Inspection. The contents of activities are described about the following 15 items: standards, minimum discernible contrast and image distribution, contrast meter and penetrameter sensitivity, testing conditions, detection limit and simulation, photographing method for tube welding and corner welding, relationship between irradiation direction and flaw detectability, abnormal images, RI sources, X-ray equipment and observing device, sensitive materials, detectors, image processing and X-ray TV and automation, neutron radiography, other application and new techniques, and safety. Concerning the ''standards'', discussion was performed on revising JIS Z 3105 ''Methods of Radiographic Test and Classification of Radiographs for Aluminum Welds''. In ''Abnormal images'', the verification by the author that the abnormal shadows generated in the radiographic images of austenitic steel welded parts are the diffraction phenomenon to satisfy the Bragg's conditions is reported. In ''RI sources'', Yb-169 was found to be a good radiation source for relatively thin steel plates. In ''neutron radiography'', it was confirmed that the neutron radiography using a cyclotron as a neutron source can be used practically by its fundamental tests. ''Application and new techniques'' include a trial to utilize scattered radiation as a source, the testing method of γ shield for spent fuel transportation, the improvement of X-ray radiographic test for titanium thin plates and thin wall tubes, and others. (Wakatsuki, Y.)

  12. Radiographic anatomy of juvenile bovine limbs.

    Science.gov (United States)

    Hoey, S E; Biedrzycki, A H; Livesey, M J; Drees, R

    2016-11-26

    Juvenile bovine patients who present with clinical signs of lameness are commonly evaluated using radiographic techniques both within a hospital setting and in a farm environment. The radiographic development of the juvenile bovine skeleton is currently poorly documented. In this study, the limbs of four heifer calves were sequentially radiographed to assess development of the juvenile bovine appendicular skeleton in the first 12 months of life. Images were acquired at three weeks, three months, six months, nine months and one year of age. The normal radiographic anatomy of the fore limbs and hindlimbs and the changes over the first 12 months are described. The majority of physes remain open throughout this period, with the exception of the proximal physes of the proximal and middle phalanges, the proximal radial physis, and the proximal humeral physis which close radiographically between 9 months and 12 months of age, and fusion of the fourth and central tarsal bones occurs between 9 months and 12 months of age. The results of this study may aid in differentiating normal and abnormal anatomy in the juvenile bovine limb. British Veterinary Association.

  13. Growing teratoma syndrome: clinical and radiographic characteristics.

    Science.gov (United States)

    Lee, Dennis J; Djaladat, Hooman; Tadros, Nicholas N; Movassaghi, Mehran; Tejura, Tapas; Duddalwar, Vinay; Daneshmand, Siamak

    2014-09-01

    To present an overview of our surgical experience in the management of growing teratoma syndrome. A retrospective analysis of all patients undergoing post-chemotherapy retroperitoneal lymphadenectomy between November 2005 and February 2012 revealed 15 patients who met the criteria for growing teratoma syndrome. Their clinical data, imaging characteristics, and surgical and oncological outcomes were reviewed. The median age at diagnosis was 23 years. Primary testis tumors included non-seminomatous germ cell tumor in 12 of 15 patients, seminoma in two of 15 patients and hemorrhagic mass in one patient. Mature teratoma was present in just six (40%) of the orchiectomy specimens. All patients received preoperative chemotherapy. On imaging, the median size of the largest retroperitoneal mass was 7 cm (range 3.9-24.5 cm). The median rate of linear growth was 0.5 cm/month (range 0.03-2.9), and the increase in volume was 9.2 cm(3) /month. All tumors were found to have cystic and necrotic components. Median operative time was 6.2 h (range 4.2-15.2 h). Estimated blood loss was 600 mL (range 100-7000 mL), and median length of stay was 5 days (range 3-19 days). Four patients required resection of non-retroperitoneal growing teratoma masses after post-chemotherapy retroperitoneal lymphadenectomy to achieve tumor-free status. There were two minor (Clavien I-II) and two major postoperative complications (Clavien ≥III). All patients are alive and disease free with a median duration of follow-up of 8 months (range 1-64 months). Growing teratoma syndrome tumors vary in their growth rate, but they all appear to have cystic features with necrosis elements on radiographic evaluation. Aggressive surgical excision is associated with excellent outcomes. © 2014 The Japanese Urological Association.

  14. Training radiographers to deliver an intervention to promote early presentation of breast cancer

    International Nuclear Information System (INIS)

    Burgess, Caroline; Teasdale, Emma; Omar, Lynne; Tucker, Lorraine; Ramirez, Amanda-Jane

    2012-01-01

    Aim: To evaluate the feasibility of training sufficient radiographers to deliver an intervention to promote early presentation of breast cancer to all older women attending for their final routine mammogram within the NHS Breast Screening Programme. If the Promoting Early Presentation (PEP) intervention is demonstrated to be cost-effective, it may be implemented across the NHS requiring at least four radiographers per screening service to deliver the intervention. Methods: A pilot study in a single breast screening service was conducted to assess the feasibility of training sufficient radiographers to meet this objective. Quantitative and qualitative methods were used to evaluate the impact of training on participating radiographers and the screening service. Competency to deliver the intervention was assessed at key points during training according to quality criteria based on delivery of the key messages and style of delivery. Confidence to deliver the intervention was assessed using a self-report measure before and after training. Radiographers' experiences of training were elicited in face-to-face qualitative interviews. Results: Seven of eight radiographers who were released to undertake the training achieved the required level of competency to deliver the intervention within four months. All improved over time in their confidence to deliver the key messages of the intervention. The qualitative analysis revealed the benefits and challenges of training from the perspective of the radiographers. Conclusion: It was feasible and acceptable to train sufficient radiographers to deliver the PEP Intervention. The training package will be streamlined to improve efficiency for large implementation trials and clinical practice across the NHS.

  15. Estrategias narrativas orientadas a la construcción de niveles de lectura en el cine de animación de Pixar (1995-2010)

    OpenAIRE

    Pérez Guerrero, Ana María

    2012-01-01

    Tesis Doctoral leída en la Universidad Rey Juan Carlos de Madrid en 2011. Directores de la Tesis: Antonio Sánchez-Escalonilla García-Rico y Araceli Rodríguez Mateos El cine de animación experimentó un segundo florecimiento a finales de la década de los 80. El éxito de títulos como La sirenita (1989), La bella y la bestia (1991), Aladdin (1992) o El rey león (1994) son muestras del alcance de un tipo de largometrajes que impulsaron una nueva edad de oro del medio. Entre los rasgos más...

  16. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  17. The review on radiographic inspection in 1978

    International Nuclear Information System (INIS)

    Furuta, Junichiro

    1979-01-01

    This is a review paper on the activities of radiographic inspection performed in 1978. The state of safety management in 1978 is reported. The JIS standards for the radiographic inspection were investigated. Problems concerning the measurement of the height of defects by non-destructive test were studied. The radiographic method with narrow irradiation field was developed. Radiography of the welded parts at corners, fiber reinforced plastics, offshore structures, nozzles, pipes and so on was investigated. Scattering ratio, contrast, and beam quality affect on identification, and these effects were studied. Defect-like patterns seen in X-ray graphs of cast metals and welded parts are due to X-ray diffraction. The relation between exposure and density of pictures was obtained as linear relation. The property of scattering ratio and an empirical formula were deduced. Development of instruments and films have been made. (Kato, T.)

  18. Cine, literatura y mito: Don Quijote en el cine, más allá de la adaptación

    Directory of Open Access Journals (Sweden)

    Pardo García, Pedro Javier

    2011-04-01

    Full Text Available This paper discusses Don Quixote’s presence in film, but in terms of the myth rather than the book, an approach which goes beyond adaptation and opens up the field of study in a significant way. In so doing it proposes a tentative but coherent description of the quixotic myth or narrative pattern as that of the inadequate and romantic imitator/reader of fiction, which is the point of departure for the elaboration of an initial corpus of quixotic movies. The protagonists of these films are frustrated imitators of cinematographic models, female Quixotes who romanticize reality and heroes who are Quixotic because they are not fit for the heroic task they have undertaken. In order to illustrate this deep penetration of the myth into the cinematic medium, a recent example in Spanish cinema will be examined, The Heart of the Warrior (El corazón del guerrero, 2000, a film directed by Daniel Monzón, where these several varieties are at work in a combined and crystal clear way. Our survey will allow us to make a series of distinctions which organise and structure the different kinds of relationship between Don Quixote and film (Cervantean, quixotic and quixotish film and, finally, to draw a series of theoretical conclusions which can be applied to the comparative study of film and literature.

    Este trabajo se ocupa de la presencia en el cine de Don Quijote, pero no del libro sino del mito, una perspectiva que va mucho más allá de la adaptación y abre considerablemente el campo de estudio. Para ello, se propone una descripción que se sabe provisional pero intenta ser rigurosa del mito o el patrón narrativo quijotesco como el del lector/imitador romántico e inadecuado de ficción, a partir de la cual se puede elaborar un primer corpus de películas quijotescas. En él se incluyen las protagonizadas por imitadores fallidos de modelos cinematográficos, por Quijotes femeninos que romantizan la realidad y por diversos tipos de héroes que son

  19. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  20. Manifold learning based ECG-free free-breathing cardiac CINE MRI.

    Science.gov (United States)

    Usman, Muhammad; Atkinson, David; Kolbitsch, Christoph; Schaeffter, Tobias; Prieto, Claudia

    2015-06-01

    To present and validate a manifold learning (ML)-based method that can estimate both cardiac and respiratory navigator signals from electrocardiogram (ECG)-free free-breathing cardiac magnetic resonance imaging (MRI) data to achieve self-gated retrospective CINE reconstruction. In this work the use of the ML method is demonstrated for 2D cardiac CINE to achieve both cardiac and respiratory self-gating without the need of an external navigator or ECG signal. This is achieved by sequentially applying ML to two sets of retrospectively reconstructed real-time images with differing temporal resolutions. A 1D cardiac signal is estimated by applying ML to high temporal resolution real-time images reconstructed from the acquired data. Using the estimated cardiac signal, a 1D respiratory signal was obtained by applying the ML method to low temporal resolution images reconstructed from the same acquired data for each cardiac cycle. Data were acquired in five volunteers with a 2D golden angle radial trajectory in a balanced steady-state free precession (b-SSFP) acquisition. The accuracy of the estimated cardiac signal was calculated as the standard deviation of the temporal difference between the estimated signal and the recorded ECG. The correlation between the estimated respiratory signal and standard pencil beam navigator signal was evaluated. Gated CINE reconstructions (20 cardiac phases per cycle, temporal resolution ∼30 msec) using the estimated cardiac and respiratory signals were qualitatively compared against conventional ECG-gated breath-hold CINE acquisitions. Accurate cardiac signals were estimated with the proposed method, with an error standard deviation in comparison to ECG lower than 20 msec. Respiratory signals estimated with the proposed method achieved a mean cross-correlation of 94% with respect to standard pencil beam navigator signals. Good quality visual scores of 2.80 ± 0.45 (scores from 0, bad, to 4, excellent quality) were observed for the