WorldWideScience

Sample records for chromatography-tandem quadrupole mass

  1. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  2. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  3. Determination of albendazole and metabolites in silkworm Bombyx mori hemolymph by ultrafast liquid chromatography tandem triple quadrupole mass spectrometry.

    Science.gov (United States)

    Li, Li; Xing, Dong-Xu; Li, Qing-Rong; Xiao, Yang; Ye, Ming-Qiang; Yang, Qiong

    2014-01-01

    Albendazole is a broad-spectrum parasiticide with high effectiveness and low host toxicity. No method is currently available for measuring albendazole and its metabolites in silkworm hemolymph. This study describes a rapid, selective, sensitive, synchronous and reliable detection method for albendazole and its metabolites in silkworm hemolymph using ultrafast liquid chromatography tandem triple quadrupole mass spectrometry (UFLC-MS/MS). The method is liquid-liquid extraction followed by UFLC separation and quantification in an MS/MS system with positive electrospray ionization in multiple reaction monitoring mode. Precursor-to-product ion transitions were monitored at 266.100 to 234.100 for albendazole (ABZ), 282.200 to 208.100 for albendazole sulfoxide (ABZSO), 298.200 to 159.100 for albendazole sulfone (ABZSO2) and 240.200 to 133.100 for albendazole amino sulfone (ABZSO2-NH2). Calibration curves had good linearities with R2 of 0.9905-0.9972. Limits of quantitation (LOQs) were 1.32 ng/mL for ABZ, 16.67 ng/mL for ABZSO, 0.76 ng/mL for ABZSO2 and 5.94 ng/mL for ABZSO2-NH2. Recoveries were 93.12%-103.83% for ABZ, 66.51%-108.51% for ABZSO, 96.85%-105.6% for ABZSO2 and 96.46%-106.14% for ABZSO2-NH2, (RSDs albendazole and its metabolites in silkworm hemolymph in a pharmacokinetic study. The results of single-dose treatment suggested that the concentrations of ABZ, ABZSO and ABZSO2 increased and then fell, while ABZSO2-NH2 level was low without obvious change. Different trends were observed for multi-dose treatment, with concentrations of ABZSO and ABZSO2 rising over time.

  4. Application of gas chromatography/tandem quadrupole mass spectrometry to the multi-residue analysis of pesticides in green leafy vegetables.

    Science.gov (United States)

    Walorczyk, Stanisław

    2008-12-01

    A new, sensitive and specific method has been developed for the simultaneous determination of 129 pesticides in lettuce and other green leafy vegetables. The samples were extracted with acetonitrile and co-extractives such as fatty acids and pigments were removed using dispersive solid-phase extraction (dispersive-SPE) with primary secondary amine (PSA) and graphitized carbon black (GCB). All pesticides were analyzed in a single injection gas chromatography/tandem quadrupole mass spectrometry (GC/MS/MS) acquisition method. Two multiple reaction monitoring (MRM) transitions of precursor ions fragmenting into product ions were recorded for the targeted pesticides, thus fulfilling the EU identification points system criteria for the identification of contaminants (2002/657/EC). Calibration curves were determined using matrix-matched standards, and exhibited excellent linearity at two orders of magnitude from 0.005 to 0.5 mg/kg for almost all the pesticides studied (R(2) > or = 0.99). The analytical performance was demonstrated by the analysis of lettuce samples spiked at five concentration levels ranging from 0.005 to 0.5 mg/kg for each pesticide. The recovery and repeatability results satisfied SANCO/2007/3131 criteria (i.e. average recoveries were in the range 70-120% with RSDs vegetable samples such as lettuce, cabbage and leek.

  5. Multi-class pesticide analysis in human hair by gas chromatography tandem (triple quadrupole) mass spectrometry with solid phase microextraction and liquid injection.

    Science.gov (United States)

    Salquèbre, Guillaume; Schummer, Claude; Millet, Maurice; Briand, Olivier; Appenzeller, Brice M R

    2012-01-13

    A method for the simultaneous detection and quantification of 22 pesticides from different chemical classes was developed using solid-phase microextraction (SPME) and gas chromatography tandem (triple quadrupole) mass spectrometry. Pesticides were extracted from 50mg of pulverized hair with acetonitrile. The extract was submitted to two successive steps of direct immersion-SPME at 30°C and 90°C or to a liquid injection without SPME in order to obtain optimized conditions for each of the 22 analytes investigated. Validation parameters were significantly influenced by both the injection mode (SPME vs liquid injection) and the temperature of SPME. Limits of quantification ranged from 0.05 pg mg(-1) for trifluralin to 10 pg mg(-1) for pentachlorophenol. The application of the validated method to the analysis of samples collected from non-occupationally exposed volunteers demonstrated the presence of pesticides in all the samples tested. Altogether, 13 different analytes were detected at concentration above the limit of quantification.

  6. Application of dispersive solid-phase extraction and ultra-fast liquid chromatography-tandem quadrupole mass spectrometry in food additive residue analysis of red wine.

    Science.gov (United States)

    Chen, Xiao-Hong; Zhao, Yong-Gang; Shen, Hao-Yu; Jin, Mi-Cong

    2012-11-09

    A novel and effective dispersive solid-phase extraction (dSPE) procedure with rapid magnetic separation using ethylenediamine-functionalized magnetic polymer as an adsorbent was developed. The new procedure had excellent clean-up ability for the selective removal of the matrix in red wine. An accurate, simple, and rapid analytical method using ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) for the simultaneous determination of nine food additives (i.e., acesulfame, saccharin, sodium cyclamate, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid, and neotame) in red wine was also used and validated. Recoveries ranging from 78.5% to 99.2% with relative standard deviations ranging from 0.46% to 6.3% were obtained using the new method. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.9993. The limits of quantification for the nine food additives were between 0.10 μg/L and 50.0 μg/L. The proposed dSPE-UFLC-MS/MS method was successfully applied in the food-safety risk monitoring of real red wine in Zhejiang Province, China. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  7. Ultra performance liquid chromatography-tandem quadrupole mass spectrometry profiling of anthocyanins and flavonols in cowpea (Vigna unguiculata) of varying genotypes.

    Science.gov (United States)

    Ojwang, Leonnard O; Dykes, Linda; Awika, Joseph M

    2012-04-11

    The structure of flavonoids in food plants affects bioactivity and important nutritional attributes, like micronutrient bioavailability. This study investigated flavonol and anthocyanin compositions of cowpea (Vigna unguiculata) of varying genotypes. Black, red, green, white, light brown, and golden brown cowpea phenotypes were analyzed for anthocyanins and flavonols using ultra performance liquid chromatography-tandem quadrupole mass spectrometry. Eight anthocyanins and 23 flavonols (15 newly identified in cowpea) were characterized. Mono-, di-, and tri(acyl)glycosides of quercetin were predominant in most phenotypes; myricetin and kaempferol glycosides were present only in specific phenotypes. The red phenotypes had the highest flavonol content (880-1060 μg/g), whereas green and white phenotypes had the lowest (270-350 μg/g). Only black (1676-2094 μg/g) and green (875 μg/g) phenotypes had anthocyanins, predominantly delphinidin and cyanidin 3-O-glucosides. Cowpea phenotype influenced the type and amount of flavonoids accumulated in the seed; this may have implications in selecting varieties for nutrition and health applications.

  8. Measurement of (15)N enrichment of glutamine and urea cycle amino acids derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate using liquid chromatography-tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Nakamura, Hidehiro; Karakawa, Sachise; Watanabe, Akiko; Kawamata, Yasuko; Kuwahara, Tomomi; Shimbo, Kazutaka; Sakai, Ryosei

    2015-05-01

    6-Aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) is an amino acid-specific derivatizing reagent that has been used for sensitive amino acid quantification by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). In this study, we aimed to evaluate the ability of this method to measure the isotopic enrichment of amino acids and to determine the positional (15)N enrichment of urea cycle amino acids (i.e., arginine, ornithine, and citrulline) and glutamine. The distribution of the M and M+1 isotopomers of each natural AQC-amino acid was nearly identical to the theoretical distribution. The standard deviation of the (M+1)/M ratio for each amino acid in repeated measurements was approximately 0.1%, and the ratios were stable regardless of the injected amounts. Linearity in the measurements of (15)N enrichment was confirmed by measuring a series of (15)N-labeled arginine standards. The positional (15)N enrichment of urea cycle amino acids and glutamine was estimated from the isotopic distribution of unique fragment ions generated at different collision energies. This method was able to identify their positional (15)N enrichment in the plasma of rats fed (15)N-labeled glutamine. These results suggest the utility of LC-MS/MS detection of AQC-amino acids for the measurement of isotopic enrichment in (15)N-labeled amino acids and indicate that this method is useful for the study of nitrogen metabolism in living organisms.

  9. Determinations of airborne synthetic musks by polyurethane foam coupled with triple quadrupole gas chromatography tandem mass spectrometer.

    Science.gov (United States)

    Wang, I-Ting Ivy; Cheng, Shu-Fang; Tsai, Shih-Wei

    2014-02-21

    Synthetic musk is widely used in various scented consumer products. However, the exposure via inhalation is often ignored due to pleasant smells. In addition, the information regarding the distribution of synthetic musk in air is limited. Hence, this research is aimed to develop a highly sensitive and widely applicable method for the determination of airborne synthetic musk. In this study, polyurethane foam (PUF) and filter were employed for active air sampling. Microwave assisted extraction (MAE) and nitrogen evaporator were performed for sample preparation. A gas chromatography coupled with triple quadrupole tandem mass spectrometer (GC/MS-MS) with specific multiple reaction monitoring (MRM) transition pairs was applied for sample analysis. Compared with using selected ion monitoring (SIM) mode traditionally, the sensitivities were improved in this study about an order at least. In terms of air concentration, as low as 0.48ngm(-3) can be determined when sampling at 3.5Lmin(-1) for 8h. The method established was further applied to the analysis of synthetic musk compounds in air samples collected in a cosmetics plant. The results showed that the airborne concentrations of gaseous polycyclic musk, gaseous nitro-musk, and particle-phase polycyclic musk were 6.4×10(2), 4.0×10(1) and 3.1×10(2)ngm(-3), respectively. Meanwhile, Cashmeran, Celstolide, Galaxolide, and Tonalide were found as the dominant musk compounds in the factory investigated.

  10. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds.

  11. Liquid chromatography tandem mass spectrometric quantitation of sulfamethazine and its metabolites: direct analysis of swine urine by triple quadrupole and by ion trap mass spectrometry.

    Science.gov (United States)

    Bartolucci, G; Pieraccini, G; Villanelli, F; Moneti, G; Triolo, A

    2000-01-01

    This work describes a new method for the quantitation of trace amounts of sulfamethazine (SMZ) and its main metabolite, N4-acetylsulfamethazine (Ac-SMZ), in swine urine, using high-performance liquid chromatography (HPLC) tandem mass spectrometric analysis of crude urine after addition of internal standard and simple dilution with water. The aim was to determine whether residues of this sulfamidic drug, normally administered to swine in order to prevent infectious diseases, were present in urine at levels lower than those permitted by regulatory authorities before human consumption (EU Project SMT, contract number CT 96-2092). A 10 microL volume of diluted urine was injected into a very short, narrow-bore chromatographic column (Zorbax SB-C18 2.1 i. d. x30 mm length, 3.5 microm pore size). Elution of the analytes of interest was achieved in less than seven minutes using a rapid gradient (from 20 to 80% methanol in 3 minutes). Either a PE Sciex API 365 triple quadrupole (QqQ), operated in the selected reaction monitoring (SRM) mode, or a Finnigan LCQ ion trap (IT) mass spectrometer, operated in narrow-range product ion scan, was used as the final detector. Electrospray (ESI) was used as the ionization technique. A comparison of the two tandem mass spectrometers was performed by analyzing the same set of test samples, at three concentration levels, on three different days. Linearity of responses of the calibration standards, intra- and inter-assay precision of the samples, specificity and limits of detection were evaluated for both systems. Both the QqQ and the IT instrument was suitable for rapid, sensitive and specific determination of the analytes, although the overall performance of the QqQ was slightly superior in terms of linearity, precision and sensitivity.

  12. Streamlined pentafluorophenylpropyl column liquid chromatography-tandem quadrupole mass spectrometry and global (13)C-labeled internal standards improve performance for quantitative metabolomics in bacteria.

    Science.gov (United States)

    Yang, Song; Sadilek, Martin; Lidstrom, Mary E

    2010-11-19

    Streamlined quantitative metabolomics in central metabolism of bacteria would be greatly facilitated by a high-efficiency liquid chromatography (LC) method in conjunction with accurate quantitation. To achieve this goal, a methodology for LC-tandem quadrupole mass spectrometry (LC-MS/MS) involving a pentafluorophenylpropyl (PFPP) column and culture-derived global (13)C-labeled internal standards (I.Ss.) has been developed and compared to hydrophilic interaction liquid chromatography (HILIC)-MS/MS and published combined two-dimensional gas chromatography and LC methods. All 50 tested metabolite standards from 5 classes (amino acids, carboxylic acids, nucleotides, acyl-CoAs and sugar phosphates) displayed good chromatographic separation and sensitivity on the PFPP column. In addition, many important critical pairs such as isomers/isobars (e.g. isoleucine/leucine, methylsuccinic acid/ethylmalonic acid and malonyl-CoA/3-hydroxybutyryl-CoA) and metabolites of similar structure (e.g. malate/fumarate) were resolved better on the PFPP than on the HILIC column. Compared to only one (13)C-labeled I.S., the addition of global (13)C-labeled I.Ss. improved quantitative linearity and accuracy. PFPP-MS/MS with global (13)C-labeled I.Ss. allowed the absolute quantitation of 42 metabolite pool sizes in Methylobacterium extorquens AM1. A comparison of metabolite level changes published previously for ethylamine (C2) versus succinate (C4) cultures of M. extorquens AM1 indicated a good consistency with the data obtained by PFPP-MS/MS, suggesting this single approach has the capability of providing comprehensive metabolite profiling similar to the combination of methods. The more accurate quantification obtained by this method forms a fundamental basis for flux measurements and can be used for metabolism modeling in bacteria in future studies. Published by Elsevier B.V.

  13. Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma.

    Science.gov (United States)

    Liu, Fei; Xu, Yu; Rui, Lei; Gao, Shu; Dong, Haijun; Guo, Qingxiang

    2006-01-01

    A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.

  14. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Vivek Upadhyay; Vikas Trivedi; Gaurang Shah; Manish Yadav; Pranav S. Shrivastav

    2014-01-01

    A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 mL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100mm*2.1mm,1.7mm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was 495%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  15. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Vivek Upadhyay

    2014-06-01

    Full Text Available A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  16. Liquid chromatography-tandem mass spectrometric assay for the PARP inhibitor rucaparib in plasma.

    Science.gov (United States)

    Sparidans, Rolf W; Durmus, Selvi; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for the poly(ADP-ribose) polymerase-1 inhibitor rucaparib was developed and validated. Plasma samples were pre-treated using protein precipitation with acetonitrile containing gefitinib as internal standard. Diluted extract was directly injected into the reversed-phase chromatographic system. The eluate was transferred into the electrospray interface with positive ionization and the analyte was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. The assay was validated in a 1.25-2000ng/ml calibration range with r(2)=0.9958±0.0012 for linear regression with quadratic weighting (n=6). Within day precisions (n=18) were 2.0-5.4%, between day (3 days; n=18) precisions 3.2-8.0% and accuracies (n=18) were 89.7-93.2%. At the lower limit of quantification (1.25ng/ml) these parameters were 9.6%, 13.7% and 85.3%, respectively. The drug was sufficiently stable under all relevant analytical conditions. Finally, the assay was successfully used to determine drug pharmacokinetics in female FVB wild type mice. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Determination of the Thyreostats in Animal Feeding Stuffs Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2014-10-01

    Full Text Available A rapid liquid chromatography tandem mass spectrometry method was developed and validated to detect and confirm five thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in animal feeding stuff samples. Thyreostats were extracted from feed with methanol, and then degreasing of the extract with petroleum ether was performed, followed by the derivatisation of the compounds with 3-iodobenzylbromide in basic medium (pH 8.0. The derivatives were extracted with diethyl ether and analysed by gradient elution on a Poroshell 120-EC C18 column with triple quadrupole MS detection with turbo spray source in positive ionisation mode. The method was validated in accordance with the Commission Decision 2002/657/EC. For validation level of 10 ļig kg-1, the recovery ranged from 82% to 97.5% for all examined compounds. The repeatability and reproducibility did not exceed the limit of 20% for all analytes. The linearity was good for all thyreostats in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limits (CCa ranged from 1.63 ļig kg-1 to 3.95 ļig kg-1, whereas the detection capabilities (CCß ranged from 2.74 ļig kg-1 to 6.73 ļig kg-1. The developed analysis is sensitive and robust, and therefore useful for quantification and confirmation of thyreostats in residue control programme.

  18. A new approach for simultaneous screening and quantification of toxic pyrrolizidine alkaloids in some potential pyrrolizidine alkaloid-containing plants by using ultra performance liquid chromatography-tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Zhou, Yan; Li, Na; Choi, Franky Fung-Kei; Qiao, Chun-Feng; Song, Jing-Zheng; Li, Song-Lin; Liu, Xin; Cai, Zong-Wei; Fu, Peter P; Lin, Ge; Xu, Hong-Xi

    2010-11-29

    A rapid, but sensitive and selective method for simultaneous screening and quantification of toxic pyrrolizidine alkaloids (PAs) by ultra performance liquid-chromatography (UPLC) coupled with tandem mass spectrometry (MS/MS) on a tandem quadrupole mass spectrometer (TQ-MS) is described. This was accomplished by incorporating the precursor ion scan (PIS) acquisition and multiple reaction monitoring (MRM) acquisition in the same UPLC-MS/MS run. Notably, the developed PIS approach for detecting two pairs of characteristic product ions at m/z 120/138 or 168/150, allowed specific identification of toxic retronecine and otonecine types PAs. This PIS method is highly sensitive with over 10-fold sensitivity improvement upon previously published LC-MS method. Moreover, this new approach is suitable for high sample throughput and was applied to the screening and quantifying toxic PAs in 22 samples collected from seven Parasenecio species and four Senecio species. In addition, coupling the MRM with PIS approach generated quantitative results equivalent to those obtained by conventional MRM-only approach. This coupled MRM with PIS approach could provide both qualitative and quantitative results without the need of repetitive analyses.

  19. Determination of RH-5849 and indoxacarb in rice straw, rice husk, brown rice and soil using liquid chromatography-tandem triple quadrupole mass spectrometry following extraction with QuEChERS method.

    Science.gov (United States)

    Li, Zhurui; Zhao, Xiaozhen; Chen, Jiaojiao; Wu, Yue; Zhang, Jing; Zhang, Kankan; Hu, Deyu

    2016-10-01

    A fast and simple analytical method was developed for the simultaneous determination of RH-5849 and indoxacarb in soil, rice straw, rice husk and brown rice. QuEChERS (quick, easy, cheap, effective, rugged and safe) method was used for extraction, and liquid chromatography with tandem triple quadrupole mass spectrometry was used for quantification. The matrix-matched calibration plots were linear in the range between 25 and 5000 μg/L for soil, rice straw, rice husk and brown rice samples. All determination coefficients (R(2) ) were ≥0.9962. The limits of detection and quantification were 1.5 and 5 μg/kg, respectively. Recoveries at three fortification levels ranged between 79.5 and 97.9% with relative standard deviations <11%. The developed method was validated and applied for the analysis of dissipation study samples. For field experiments, the half-lives of RH-5849 and indoxacarb in rice straw were 11.93 and 5.83 days, respectively. The method was demonstrated to be reliable for the routine monitoring of RH-5849 and indoxacarb in rice samples. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Direct analysis of 18 flavonol glycosides, aglycones and terpene trilactones in Ginkgo biloba tablets by matrix solid phase dispersion coupled with ultra-high performance liquid chromatography tandem triple quadrupole mass spectrometry.

    Science.gov (United States)

    Liu, Xin-Guang; Yang, Hua; Cheng, Xiao-Lan; Liu, Lei; Qin, Yong; Wang, Qi; Qi, Lian-Wen; Li, Ping

    2014-08-01

    Analysis and quality control of Ginkgo biloba have been comprehensively studied. However, little attention has been devoted to the simultaneous extraction and analysis of flavonols and terpene trilactones, especially for direct quantification of flavonol glycosides. This work described a rapid strategy for one-step extraction and quantification of the components. A matrix solid phase dispersion (MSPD) method was designed for the extraction of ginkgo ingredients and compared with the heat-reflux and ultrasonic extraction methods. An ultra-high performance liquid chromatography (UHPLC)-tandem-triple-quadrupole-mass spectrometry (QQQ-MS) method was developed for detection of the 18 components, including 10 original flavonol glycosides, 3 aglycones, and 5 lactones. Subsequently, the proposed strategy was used for the analysis of 12 G. biloba tablets. Results showed that MSPD produced comparable extraction efficiency but consumed less time and required lower solvent volumes compared with conventional methods. Without hydrolysis, the concentration detected was much closer to the original in the sample. The total flavonol glycoside contents in ginkgo tablets ranged from 3.59 to 125.21μgmg(-1), and the terpene trilactone varied from 3.45 to 57.8μgmg(-1) among different manufacturers. In conclusion, the proposed MSPD and UHPLC-QQQ-MS is rapid and sensitive in providing comprehensive profile of chemical constituents especially the genuine flavonol glycosides for improved quality control of ginkgo products.

  1. Multilaboratory validation of a method to confirm chloramphenicol in shrimp and crabmeat by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hammack, Walter; Carson, Mary C; Neuhaus, Barbara K; Hurlbut, Jeffrey A; Nochetto, Cristina; Stuart, James S; Brown, Amy; Kilpatrick, Donna; Youngs, Kristl; Ferbos, Krystle; Heller, David N

    2003-01-01

    An existing method for chloramphenicol (CAP) determination in shrimp using a gas chromatograph with electron capture detector was adapted for confirmation of CAP with a liquid chromatograph interfaced to a triple quadrupole mass spectrometer. CAP residues are extracted from tissue with ethyl acetate, isolated via liquid-liquid extraction, and concentrated by evaporation. Extracts are chromatographed by using a reversed-phased column and analyzed by electrospray negative mode tandem mass spectrometry. Four product ions (m/z 152, 176, 194, and 257) of precursor m/z 321 were monitored. Moving from gas chromatography to liquid chromatography-tandem mass spectrometry improved the sensitivity of the method greatly, enabling reliable confirmation of CAP residues at 0.3 microg/kg (ppb). The method meets confirmation criteria recommended by the U.S. Food and Drug Administration and 4-point identification criteria established by the European Union. With slight modifications to accommodate different equipment, the method was validated in 3 laboratories.

  2. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  3. Protein identification using nano liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Negroni, Luc

    2007-01-01

    Tandem mass spectrometry is an efficient technique for the identification of peptides on the basis of their fragmentation pattern (MS/MS scan). It can generate individual spectra for each peptide, thereby creating a powerful tool for protein identification on the basis of peptide characterization. This important advance in automatic data acquisition has allowed an efficient association between liquid chromatography and tandem mass spectrometry, and the use of nanocolumns and nanoelectrospray ionization has dramatically increased the efficiency of this method. Now large sets of peptides can be identified at a femtomole level. At the end of the process, batch processing of the MS/MS spectra produces peptide lists that identify purified proteins or protein mixtures with high confidence.

  4. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  6. Determination of Warfarin and Its Metabolite in Human Plasma by Ultra Performance Liquid Chromatog-raphy Tandem Quadrupole Mass Spectrometry (UPLC-MS/MS)%超高效液相串联质谱法检测人血浆中华法林及其代谢产物的浓度

    Institute of Scientific and Technical Information of China (English)

    邹晓华; 王双虎; 周云芳

    2015-01-01

    Objective:To establish an ultra performance liquid chromatography-tandem quadrupole mass spectrometry method for the determination of warfarin and its metabolite 7-hydroxywarfarin in human plasma. Methods: An ACQUITY UPLC® BEH C18 (50 mm × 2. 1 mm, 1. 7 μm) column was used as the stationary phase at 40℃. The mobile phase consisted of acetonitrile and water (con-taining 0. 1% formic acid) with gradient elution at a flow rate of 0. 4 ml·min-1 . Warfarin-d5 was used as the internal standard. The analytes were detected on a triple-quadrupole mass spectrometer equipped with an ESI interface in a positive mode. Results:The reten-tion time of warfarin and 7-hydroxywarfarin was 1. 8 min and 1. 5 min, respectively. Excellent linear calibration curve of warfarin and 7-hydroxywarfarin was obtained within the concentration range of 25-2 000 ng · ml-1 ( r =0. 999 3 ) and 5-500 ng · ml-1 ( r =0. 999 6), respectively. The lower limit of quantification of warfarin and 7-hydroxywarfarin was 5 ng·ml-1 and 2. 5 ng·ml-1 with the average recovery of 96. 9%-105. 3% and 97. 1% -103. 3%, respectively. The intra-and inter-day standard deviations were both less than 10%. Conclusion: The method is accurate and simple, and suitable for the determination of warfarin and its metabolite 7-hydroxywarfarin in human plasma.%目的::建立快速检测人血浆中华法林及其代谢产物7-羟基华法林浓度的UPLC-MS/MS方法。方法:用乙腈沉淀血浆蛋白的方法处理,运用Waters XEVO TQD三重四级杆液质联用仪,色谱柱为ACQUITY UPLC® BEH C18柱(50 mm ×2.1 mm,1.7μm);流动相为乙腈-水(含0.1%甲酸),梯度洗脱,流速为0.4 ml·min-1,柱温为40℃,内标为华法林-d5;质谱条件:电喷雾离子化源(ESI),正离子检测模式。结果:华法林和代谢产物7-羟基华法林的保留时间分别为1.8 min和1.5 min,线性范围分别为25~2000 ng·ml-1(r=0.9993)和5~500 ng· ml-1(r=0.9996),最低定量限分别为5,2.5 ng·ml-1,

  7. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection.

  8. Determination of Ephedra Alkaloids by Liquid Chromatography/Tandem Mass Spectrometry

    Science.gov (United States)

    Sullivan, Darryl; Wehrmann, James; Schmitz, John; Crowley, Richard; Eberhard, Jeffrey

    2008-01-01

    In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC–MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level >0.5 μg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 μg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients >0.995. PMID:12852561

  9. Analysis of acrylamide in cooked foods by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Rosén, Johan; Hellenäs, Karl-Erik

    2002-07-01

    A method using liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray for the analysis of acrylamide in foods is reported. The method comprises the addition of deuterium-labelled acrylamide-d3, extraction with water, mixed mode solid phase extraction, ultrafiltration and a graphitised carbon column for chromatography. The transitions m/z 72 > 55, 72 > 54, 72 > 44, 72 > 27, 72 > 72 and 75 > 58 were recorded in multiple reaction monitoring mode for identification and quantification. In-house validation data for products from potatoes and cereals (30 to 10,000 microg kg(-1)) are presented (accuracy 91 to 102%, relative standard deviation 3 to 21%). Interlaboratory validation data (comparison with gas chromatography mass spectrometry, 25 to 2000 microg kg(-1)) showed excellent results (r2 = 0.998).

  10. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples.

  11. Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids.

    Science.gov (United States)

    Keevil, Brian G

    2013-10-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) is increasingly becoming the method of choice for steroid hormone measurements due to small sample volumes, fast analysis times and improved specificity compared to immunoassays. Achievement of demanding analytical targets for steroid analysis is now becoming possible because of improvements in sample preparation technology, liquid chromatography column technology and mass spectrometer design. The most popular sample treatment strategies comprise protein precipitation (PP), solid-phase extraction (SLE) and liquid-liquid extraction (LLE). Modern liquid chromatography columns can ensure the adequate separation of isobaric compounds e.g. 21 Deoxycortisol, 11 Deoxycortisol and Corticosterone. The most appropriate method may be chosen to improve assay sensitivity by reducing matrix effects (LLE, SPE) or simplicity and speed (PP). Specific examples of some clinically important steroids including oestradiol, aldosterone, renin, serum cortisol, salivary cortisol and salivary testosterone will be described.

  12. Determination of Platycodin D and Platycodin D3 in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50–10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD, platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG.

  13. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Soo; Cho, Eun Gi; Huh, Wooseong; Ko, Jaewook; Jung, Jin Ah; Lee, Sooyoun [Samsung Medical Center, Seoul (Korea, Republic of)

    2013-08-15

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R{sup 2} > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

  14. Pharmacokinetics of honokiol after intravenous guttae in beagle dogs assessed using ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Liang, Yi; Cui, Gang; Wang, Xiaoxue; Zhang, Wei; An, Quan; Lin, Zongtao; Wang, Hong; Chen, Shizhong

    2014-10-01

    A simple, rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of honokiol in beagle dog plasma after intravenous guttae. With addition of the internal standard magnolol, plasma samples were precipitated with methanol and separated on a Shim-pack XR-ODS II (2.0 × 100 mm, 2.2 µm) with isocratic elution of methanol and water (80:20) solution at a flow rate of 0.2 mL/min. A good separation of honokiol was achieved within 3.5 min. Quantification was performed on a Waters Quattro Premier XE triple quadrupole mass spectrometer with electrospray ionization inlet in the negative multiple reaction monitoring mode. Good linearity was obtained over the concentration range of 5.12-15580 ng/mL (r(2) > 0.998). Intra- and inter-day precisions were <13.10%, and accuracy ranged from 89.21 to 99.92%. The lower limit of quantification for honokiol was 5.12 ng/mL, and honokiol was stable under various conditions (three freeze-thaw cycles, short-term temperature, post-preparative and long-term temperature conditions.). This validated method was successfully applied to the pharmacokinetic study of honokiol in dogs by intravenous guttae.

  15. Liquid chromatography-tandem mass spectrometric assay for the cyclin-dependent kinase inhibitor AT7519 in mouse plasma.

    Science.gov (United States)

    Dolman, M Emmy M; den Hartog, Ilona J M; Molenaar, Jan J; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2014-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for the cyclin-dependent kinase inhibitor AT7519 in mouse plasma was developed and validated. Plasma samples were pre-treated using protein precipitation with acetonitrile containing rucaparib as internal standard. After dilution with water, the extract was directly injected into the reversed-phase LC system. The eluate was transferred into the electrospray interface with positive ionization and the analyte was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. The assay was validated in a 5-10,000ng/ml calibration range using double logarithmic calibration, 5ng/ml was the lower limit of quantification. Within day precisions (n=6) were 2.9-5.6%, between day (3 days; n=18) precisions 3.2-7.2%. Accuracies were between 95.9 and 99.0% for the whole calibration range. The drug was stable under all relevant analytical conditions. Finally, the assay was successfully used to determine plasma pharmacokinetics after intraperitoneal administration of AT7519 in mice with neuroblastoma xenografts. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  17. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  18. Determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization.

    Science.gov (United States)

    Chen, Xiaoyan; Zhong, Dafang; Han, Ying; Xie, Zhiyong

    2003-01-01

    A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration. Copyright 2002 John Wiley & Sons, Ltd.

  19. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively.

  20. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hadjigeorgiou, M; Papachrysostomou, Ch; Theodorou, Z; Kanari, P; Constantinou, S

    2009-04-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CCalpha is 0.12 microgkg(-1), and the detection capability; CCbeta value is 0.16 microgkg(-1).

  1. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hadjigeorgiou, M. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)], E-mail: mhadjigeorgiou@sgl.moh.gov.cy; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)

    2009-04-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CC{alpha} is 0.12 {mu}g kg{sup -1}, and the detection capability; CC{beta} value is 0.16 {mu}g kg{sup -1}.

  2. 液相色谱串联四极杆质谱法同时测定婴幼儿配方食品中甲基香兰素和乙基香兰素%Simultaneous determination of vanillin and ethyl vanillin in infant formulas using liquid chromatography tandem quadrupole mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    罗冠中; 刘祥; 孟云彩

    2011-01-01

    A method is presented for the quantitative determination and confirmation of vanillin and ethyl vanillin in infant formulas by mixed anion-exchange solid phase extraction cartridge clean-up and liquid chromatography tandem quadrupole mass spectrometry ( HPLC/MS/MS). Acetonitrile and water were used as extraction solvents,and CuSO4 solution was used to precipitate protein in the sample. And then the solubility of the target compound was obviously improved by adjusting pH with NaOH solution. An aliquot of the supernatant was cleaned up using anion-exchange solid phase extraction cartridge. Chromatographic separation was performed on a C18 column with the gradient elution and the mass spectrometric acquisition was carried out under the ESI negative mode of multiple-reaction monitoring ( MRM). Baby formula milk powder,rice flour,fruits and vegetables mud and muddy flesh were selected as matrix spike blank samples in this test,as a result,the limits of determination (LOD) of vanillin and ethyl vanillin are 1~5μg/kg and 0.5-1μg/kg,respectively. The average recoveries of vanillin are from 65% to 96% with the relative standard deviations (RSDs) of 3. 3% ~ 7.9% ; and the average recoveries of ethyl vanillin are from 63% to 92% with the relative standard deviations (RSDs) of 4. 3% ~8. 2%. This method has the high sensitivity and can be applied to test and supervision of trace of aromatic chemicals added in infant formulas.%建立了混合阴离子交换固相萃取柱净化,液相色谱串联四极杆质谱法测定婴幼儿配方食品中甲基香兰素和乙基香兰素的方法.样品经水和乙腈提取,CuSO4溶液沉淀蛋白,NaOH调节pH,增加样品溶解性,阴离子交换固相萃取柱净化.目标化合物在梯度洗脱条件下经C18柱分离后采用ESI源负离子多反应监测模式进行检测.分别选取了婴幼儿配方乳粉、米粉、果蔬泥、肉泥作为样品基质,经空白样品添加标准样品进行测试,结果表明:甲

  3. Multi-residue determination of plant growth regulators in apples and tomatoes by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Xue, Jiaying; Wang, Suli; You, Xiangwei; Dong, Jiannan; Han, Lijun; Liu, Fengmao

    2011-11-15

    A sensitive and rapid multi-residue analytical method for plant growth regulators (PGRs) (i.e., chlormequat, mepiquat, paclobutrazol, uniconazole, ethephon and flumetralin) in apples and tomatoes was developed using high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). A homogenised sample was extracted with a mixture of methanol/water (90:10, v/v) and adjusted to pH <3 with formic acid. Primary secondary amine (PSA) adsorbent was used to clean up the sample. The determination was performed using electrospray ionisation (ESI) and a triple quadrupole (QqQ) analyser. Under the optimised method, the results showed that, except for ethephon, the recoveries were 81.8-98.1% in apples and tomatoes at the spiked concentrations of 0.005 to 2 mg/kg, with relative standard deviations (RSDs) of less than 11.7%. The limits of quantification (LOQs) were lower than their maximum residue limits (MRLs). The procedure was concluded as a practical method to determine the PGR residues in fruit and vegetables and is also suitable for the simultaneous analysis of the amounts of samples for routine monitoring. The analytical method described herein demonstrates a strong potential for its application in the field of PGR multi-residue analysis to help assure food safety.

  4. [Determination of 14 mycotoxins in Chinese herbs by liquid chromatography-tandem mass spectrometry with immunoaffinity purification].

    Science.gov (United States)

    Ge, Baokun; Zhao, Kongxiang; Wang, Wei; Mi, Jiebo

    2011-06-01

    A method was developed for the determination of 14 mycotoxins, aflatoxins, T-2, HT-2, fumonisins, ochratoxin A, zearalenone, etc. in Chinese herbs by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The sample was extracted with phosphate buffer solution (PBS) and methanol in turn, and then purified by a high selective multi-functional immunoaffinity column. The column was washed by PBS (containing 0.1% Twain) and water, and then eluted by methanol. The eluate was dried under nitrogen, dissolved in methanol-10 mmol/L NH4Ac (40 : 60, v/v) solution. The mycotoxins were separated on a Waters Xterra C18 MS column (100 mm x 2.1 mm, 3.5 microm) and detected by MS/MS. The limits of quantification (LOQs) of the 14 mycotoxins were from 1.0 to 5.0 microg/kg. The average recoveries of the 14 mycotoxins spiked in Chinese herbs (Ginseng, Campanulaceae, Radix and Ophiopogonis) ranged from 71.9% to 99.7% at the three spiked levels of 1.0, 5.0, 10.0 microg/kg, and the relative standard deviations (RSDs, n = 6) were between 4.8% and 15.8%. The method is rapid, sensitive and accurate, and suitable for the determination of the 14 mycotoxins in Chinese medicines. The quantification limits of aflatoxins can meet the domestic and foreign requirements.

  5. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  6. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  7. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties...

  8. Structural Elucidation of DNA-Protein Crosslinks Using Reductive Desulfurization and Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Wickramaratne, Susith; Tretyakova, Natalia Y.

    2014-01-01

    Structural characterization of DNA-protein crosslinks involving cysteine using reductive desulfurization in combination with liquid chromatography-tandem mass spectrometry is highlighted. The novel approach was used to identify hydrolytically stable DNA-protein lesions involving alkylguanine DNA alkyltransferase (AGT).

  9. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...

  10. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  11. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    NARCIS (Netherlands)

    Ham, M. van der; Koning, T.J. de; Lefeber, D.J.; Fleer, A.; Prinsen, B.H.; Sain-van der Velden, M.G. de

    2010-01-01

    BACKGROUND: Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was v

  12. 超高效液相色谱-质谱联用测定婴幼儿配方奶粉中的维生素B_(12)%Determination of Vitamin B_(12) in Infant Formula Milk Powder by Ultra Performance Liquid Chromatography-tandem Quadrupole Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    徐双阳; 许荣年; 汪庆旗; 杨琳; 宋根林

    2011-01-01

    建立了婴幼儿配方奶粉中维生素B12的超高效液相色谱-质谱联用测定方法。样品用10mmol/L醋酸铵溶解,再用三氯甲烷沉淀蛋白,滤液经AgilentSB-C8柱(4.6mm×100mm,1.8μm)进行分离,流速为0.5mL/min,进样体积10μL,柱温40℃,流动相为甲醇和10mmol/L醋酸铵,梯度洗脱。采用ESI离子源,正离子模式,以MRM方式进行定量,定量离子(m/z)为678.3/147。维生素B12在0.20~10.00ng/mL范围内线性关系良好,方法最低检测限为0.45ng/g,定量限为1.5ng/g,精密度在2.0%之内,加标回收率在94.0%~105.3%。本方法分析速度快,灵敏度高,重复性好,适用于婴幼儿配方奶粉中维生素B12的分析。%A method for determination of vitamin B12 in infant formula milk powder is developed by ultra performance liquid chromatography-tandem quadrupole mass spectrometry(UPLC-MS/MS).After being dissolved by 10 mmol/L ammonium acetate,the sample was treated by chloroform to precipitate the milk protein.Then the filtrate was separated by an Agilent SB-C8(4.6mm×100mm,1.8 μm) column with a mobile phase consisting of 10 mmol/L ammonium acetate and methanol with gradient elution.The injection volume was 10 μL at a flow-rate of 0.5mL/min and the column temperature was 40 ℃.The sample was analyzed using multiple reaction monitoring(MRM) mode via electrospray ionization(ESI) source and selecting(m/z) 678.3/147 as quantitative product ion.A good linear calibration was obtained for 0.20~10.00 ng/mL vitamin B12 with a correlation coefficient of 0.999 9.The detection limit of method was 0.45 ng/g and the quantification limit was 1.5 ng/g.The relative standard deviation of 6 infant formula milk powders was less than 2.0%.The recovery was between 94.0%~105.3%(n=6).Since its short operation time,high sensitivity and good reproducible,the proposed method can be used to determine vitamin B12 in infant formula milk powder.

  13. Determination of Candesartan in Human Plasma with Liquid Chromatography - Tandem Mass Spectrometry.

    Science.gov (United States)

    Forjan, Vanja; Cvitkovič Maričič, Lea; Prosen, Helena; Brodnjak Vončina, Darinka

    2016-01-01

    A sensitive, specific and rapid liquid chromatography - tandem mass spectrometry method was developed and validated for the determination of candesartan in human plasma. Analyte was separated from endogenous components present in plasma by solid phase extraction. Chromatographic separation was performed on Gemini C18 analytical column using mobile phase acetonitrile - 5 mM ammonium formate pH 2 (90:10, v/v) at flow rate of 0.3 mL/min. For detection, tandem mass spectrometry in SRM mode with positive electrospray ionization was used. The mass transitions m/z 441.1 > 263.1 and 445.1 > 267.1 were used to determine candesartan by using candesartan-d4 as an internal standard. After development, the method was validated according to the requirements of EMA regulatory guidelines in the concentration range 1 - 400 ng/ml in human plasma. Limit of quantification (LLOQ) was 1 ng/ml. The developed and validated method proved to be very fast and reproducible and was therefore successfully implemented in pharmacokinetic and bioequivalence studies with large number of study samples.

  14. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    OpenAIRE

    Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu

    2009-01-01

    Liquid chromatography (LC) coupled with mass spectrometry (MS) detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of bisoprolol in human plasma s...

  15. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  16. Determination and pharmacokinetic studies of arecoline in dog plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Bing; Zhou, Xu-Zheng; Li, Jian-Yong; Yang, Ya-Jun; Niu, Jian-Rong; Wei, Xiao-Juan; Liu, Xi-Wang; Li, Jin-Shan; Zhang, Ji-Yu

    2014-10-15

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of arecoline concentration in dog plasma. Plasma sample was prepared by protein precipitation using n-hexane (containing 1% isoamyl alcohol) with β-pinene as an internal standard. Chromatographic separation was achieved on an Agilent C18 column (4.6×75mm, 3.5μm) using methanol: 5mM ammonium acetate as the mobile phase with isocratic elution. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve for arecoline was linear over a concentration range of 2-500ng/mL. The intra-day and inter-day accuracy and precision were within the acceptable limits of ±10% at all concentrations. In summary, the LC-MS/MS method described herein was fully validated and successfully applied to the pharmacokinetic study of arecoline hydrobromide tablets in dogs after oral administration. Copyright © 2014. Published by Elsevier B.V.

  17. Quantitative analysis of the tumor suppressor dendrogenin A using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Noguer, Emmanuel; Soules, Régis; Netter, Claude; Nagarathinam, Citra; Leignadier, Julie; Huc-Claustre, Emilie; Serhan, Nizar; Rives, Arnaud; de Medina, Philippe; Silvente-Poirot, Sandrine; Poirot, Marc

    2017-07-03

    Dendrogenin A (DDA) was recently identified as a mammalian cholesterol metabolite that displays tumor suppressor and neurostimulating properties at low doses. In breast tumors, DDA levels were found to be decreased compared to normal tissues, evidencing a metabolic deregulation of DDA production in cancers. DDA is an amino-oxysterol that contains three protonatable nitrogen atoms. This makes it physico-chemically different from other oxysterols and it therefore requires specific analytical methods We have previously used a two-step method for the quantification of DDA in biological samples: 1) DDA purification from a Bligh and Dyer extract by RP-HPLC using a 250×4.6mm column, followed by 2) nano-electrospray ionization mass spectrometry (MS) fragmentation to analyze the HPLC fraction of interest. We report here the development a liquid chromatography tandem mass spectrometry method for the analysis of DDA and its analogues. This new method is fast (10min), resolving (peak width <4s) and has a weak carryover (<0.01%). We show that this technique efficiently separates DDA from its C17 isomer and other steroidal alkaloids from the same family establishing a proof of concept for the analysis of this family of amino-oxysterols. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. [Rapid determination of 8 urinary carbamate pesticides by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Hualiang; Wang, Yuan; Zhu, Baoli

    2015-11-01

    To establish a method for simultaneously determining the urinary concentrations of 8 carbamate pesticides. After being purified by acetonitrile precipitation, urine samples were transferred to a liquid chromatography-tandem mass spectrometry system, and the concentrations of 8 carbamate pesticides were determined by external standard method. A C18 column was used for ultra-high-performance liquid chromatography; methanol/ammonium acetate solution was used as the mobile phase for gradient elution; the mass spectrometer was operated in a multi-reaction monitoring mode. The calibration curves were linear when the urinary concentrations of these carbamate pesticides were 20~800 µg/L, and the recovery rates were 61.0%~121% at spiked levels of 20, 200 and 800 µg/L, with a relative standard deviation of 1.7%~5.5%. This determination method meets the Guide for establishing occupational health standards-part 5: Determination methods of chemicals in biological materials, and can be used for simultaneous determination of 8 carbamate pesticides in the urine of poisoning patients.

  19. [Determination of glyphosate and aminomethylphosphonic acid in rice using liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Cao, Zhaoyun; Mou, Renxiang; Chen, Mingxue

    2010-08-01

    A method was developed for the determination of glyphosate (GLY) and aminomethylphosphonic acid (AMPA) in rice using liquid chromatography tandem mass spectrometry (LC-MS/MS). The sample was extracted with water followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and AMPA were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer. The derivatives of GLY and AMPA were separated on a C18 column with gradient elution with the mobile phase of acetonitrile and 5 mmol/L ammonium acetate (pH 9), and finally detected with negative ion electrospray ionization-mass spectrometry (ESI-MS) in multiple reaction monitoring (MRM) mode. The results showed that the linearities of GLY and AMPA were in the concentration range of 0.000 50 to 1.0 mg/L with the correlation coefficients of 0.999 7 and 0.999 9, respectively. The mean spiked recoveries of GLY and AMPA at 3 spiked levels ranged from 72.5% to 113.6% with the relative standard deviations (RSD, n = 5) of 3.8% - 16.2%. The limits of detection were 2.0 and 3.0 microg/kg for GLY and AMPA, respectively. This method is rapid, sensitive, and suitable for simultaneous determination of GLY and AMPA in rice.

  20. Determination of cyanuric acid residues in catfish, trout, tilapia, salmon and shrimp by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Karbiwnyk, Christine M; Andersen, Wendy C; Turnipseed, Sherri B; Storey, Joseph M; Madson, Mark R; Miller, Keith E; Gieseker, Charles M; Miller, Ron A; Rummel, Nathan G; Reimschuessel, Renate

    2009-04-01

    In May 2007, investigators discovered that waste material from the pet food manufacturing process contaminated with melamine (MEL) and/or cyanuric acid (CYA) had been added to hog and chicken feeds. At this time, investigators also learned that adulterated wheat gluten had been used in the manufacture of aquaculture feeds. Concern that the contaminated feed had been used in aquaculture and could enter the human food supply prompted the development of a method for the determination of CYA residues in the edible tissues of fish and shrimp. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was employed as a sensitive technique for the analysis of CYA in catfish, tilapia, salmon, trout and shrimp tissue. CYA was extracted from ground fish or shrimp with an acetic acid solution, defatted with hexane, and isolated with a graphitic carbon black solid-phase extraction column. Residues were separated from matrix components using a porous graphitic carbon LC column, and then analyzed with electrospray ionization in negative ion mode on a triple quadrupole mass spectrometer. Selective reaction monitoring was performed on the [M-H](-)m/z 128 ion resulting in the product ions m/z 85 and 42. Recoveries from catfish, tilapia and trout fortified with 10-100 microgkg(-1) of CYA averaged 67% with a relative standard deviation (R.S.D.) of 18% (n=107). The average method detection limit (MDL) for catfish, tilapia and trout is 3.5 microgkg(-1). An internal standard, (13)C(3)-labeled CYA, was used in the salmon and shrimp extractions. Average recovery of CYA from salmon was 91% (R.S.D.=15%, n=18) with an MDL of 7.4 microgkg(-1). Average recovery of CYA from shrimp was 85% (R.S.D.=10%, n=13) with an MDL of 3.5 microgkg(-1).

  1. Validated ultra-performance liquid chromatography tandem mass spectrometry method for the determination of pramipexole in human plasma.

    Science.gov (United States)

    Yadav, Manish; Rao, Rajasekhar; Kurani, Hemal; Rathod, Jaysukh; Patel, Rakesh; Singhal, Puran; Shrivastav, Pranav S

    2010-11-01

    A sensitive and high throughput ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method has been developed for the determination of pramipexole, a dopamine agonist, in human plasma. Sample preparation involved liquid-liquid extraction of pramipexole and ranitidine as the internal standard (IS) in ethyl acetate from 100 μL human plasma. The chromatographic separation is achieved on a Waters Acquity UPLC BEH C18 (100 mm × 2.1 mm, 1.7 μm) analytical column using an isocratic mobile phase, consisting of 10 mM ammonium formate (pH 7.50)-acetonitrile (15:85, v/v), at a flow-rate of 0.5 mL/min. The precursor → product ion transition for pramipexole (m/z 212.1 → 153.0) and IS (m/z 315.0 → 176.1) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The method was validated over a wide dynamic concentration range of 20-4020 pg/mL. Matrix effect is assessed by post-column infusion experiment and the process efficiency were 91.9% and 85.7% for pramipexole and IS, respectively. The method is rugged and rapid with a total run time of 1.5 min and is applied to a bioequivalence study of 0.25 mg PPX tablet formulation in 30 healthy Indian male subjects under fasting condition.

  2. Quantification of miltefosine in peripheral blood mononuclear cells by high-performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Kip, A.E.; Rosing, H.; Hillebrand, M.J.X.; Castro, M.M.; Gomez, M.A.; Schellens, J.H.M.; Beijnen, J.H.; Dorlo, T.P.C.

    2015-01-01

    Phagocytes, the physiological compartment in which Leishmania parasites reside, are the main site of action of the drug miltefosine, but the intracellular pharmacokinetics of miltefosine remain unexplored. We developed a bioanalytical method to quantify miltefosine in human peripheral blood mononuclear cells (PBMCs), expanding from an existing high performance liquid chromatography-tandem mass spectrometry method for the quantification of miltefosine in plasma. The method introduced deuterated miltefosine as an internal standard. Miltefosine was extracted from PBMC pellets by addition of 62.5% methanol. Supernatant was collected, evaporated and reconstituted in plasma. Chromatographic separation was performed on a reversed phase C18 column and detection with a triple-quadrupole mass spectrometer. Miltefosine was quantified using plasma calibration standards ranging from 4 to 1000 ng/mL. This method was validated with respect to its PBMC matrix effect, selectivity, recovery and stability. No matrix effect could be observed from the PBMC content (ranging from 0.17 to 26.3 × 106 PBMCs) reconstituted in plasma, as quality control samples were within 3.0% of the nominal concentration (precision less than 7.7%). At the lower limit of quantitation of 4 ng/mL plasma, corresponding to 0.12 ng/106 PBMCs in a typical clinical sample, measured concentrations were within 8.6% of the nominal value. Recovery showed to be reproducible as adding additional pre-treatment steps did not increase the recovery with more than 9%. This method was successfully applied to measure intracellular miltefosine concentrations in PBMC samples from six cutaneous leishmaniasis patients up to one month post-treatment. PMID:26160472

  3. Simultaneous determination of seventeen mycotoxins residues in Puerariae lobatae radix by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Shufang; Cheng, Ling; Ji, Shen; Wang, Ke

    2014-09-01

    This work reported an efficient and accurate liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of seventeen mycotoxins in Puerariae lobatae radix, a frequently used traditional Chinese medicine (TCM). The effects of four different clean-up methods, including TC-M160, TC-T220, Mycosep 227, and QuEChERS method, on the recoveries of mycotoxins were investigated and compared. Finally, TC-M160 was chosen for better recovery and repeatability for mycotoxins analysis. The analytes were separated on an Agilent ZORBAX SB C18 column (4.6mm×250mm, 5μm particle size), and eluted with a mobile phase consisting of (A) water containing 0.1% formic acid and (B) acetonitrile containing 0.1% formic acid at a flow rate of 0.6mL/min. The separated compounds were detected by a triple quadrupole mass spectrometer operating in positive electrospray ionization with multiple reaction monitoring (MRM) mode. The results of method validation accorded with the requirement of analytical method for mycotoxins in COMMISSION REGULATION (EC) No 401/2006. The developed method was successfully applied for determination of mycotoxins in seventeen batches of Puerariae lobatae radix collected from different provinces of China. Three batches of them were found with contamination of mycotoxins AFB1 at (0.751±0.176)μg/kg, T-2 at (1.10±0.01)μg/kg, and T-2 at (0.853±0.044)μg/kg, respectively. The results demonstrated that the proposed method was suitable for monitoring mycotoxins residues in Puerariae lobatae radix.

  4. [Determination of five coumarins in toys by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Rongjing; Wei, Biwen; Gao, Huan; Yu, Wenjia

    2012-02-01

    A rapid analytical method for the determination of five coumarins (coumarin, 7-methoxycoumarin, dihydrocoumarin, 7-methyl coumarin and 7-ethoxy-4-methyl coumarin) in toys by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After ultrasonic extraction in tetrahydrofuran, the samples were analyzed by HPLC-MS/MS in multi-reaction monitoring (MRM) mode. Acetonitrile and 0.1% acetic acid were used as the mobile phases with gradient elution. The linear ranges of calibration curves were 10 - 1 000 microg/L, and the limits of quantification (LOQ) (S/N > 10) were 2.0 microg/L for all the analytes, except that the LOQ for dihydrocoumarin was 5.0 microg/L. The recoveries of the five coumarins spiked in three types of samples were in the ranges of 93.2% - 105.8%, 97.3% - 103.2% and 96.8% - 102.9%, with the relative standard deviations in the ranges of 4.35% - 8.27%, 3.65% - 6.73% and 4.03% - 6.45%, respectively. The method was applied in the determination of 12 toy samples. The five analytes were found in 9 samples, and in some cases, the presence of quite high concentrations of these coumarins in the toys should be a matter of concern.

  5. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100 μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0 μg/kg, 0.1-4.0 μg/kg and 1.2-3.0 μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis.

  6. Analysis of amphetamines and metabolites in urine with ultra performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Ramírez Fernández, María del Mar; Wille, Sarah M R; di Fazio, Vincent; Gosselin, Matthias; Samyn, Nele

    2010-06-01

    A simple, rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and fully validated for the quantitative determination of seven amphetamines and metabolites in urine. The method was validated for selectivity, linearity, LOQ, LOD, imprecision, bias, analyte and processed sample stability, matrix effect, recovery, carryover and dilution integrity. A classic liquid-liquid extraction with ethyl acetate was used as sample preparation procedure. The compounds were separated on an Acquity UPLC HSS C18 column in 6.8 min. The linear dynamic range was established from 25 to 500 ng/mL. The limit of quantification was fixed to the lowest calibrator level and the limit of detection ranged from 0.125 to 2.5 ng/mL. The method presented an excellent intra- and inter-assay imprecision and bias (70%) were obtained for all the compounds. No carryover was observed after the analysis of high concentrated samples (8000 ng/mL). The method was subsequently applied to authentic samples.

  7. Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kutsukake, Nobuyuki; Ikeda, Koki; Honma, Seijiro; Teramoto, Migaku; Mori, Yusuke; Hayasaka, Ikuo; Yamamoto, Rain; Ishida, Takafumi; Yoshikawa, Yasuhiro; Hasegawa, Toshikazu

    2009-08-01

    Owing to its high temporal sensitivity, saliva has distinct advantages for measuring steroids, compared with other noninvasive samples such as urine and feces. Here, we report the validity of assaying salivary cortisol (C) and testosterone (T) using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in captive male chimpanzees, Pan troglodytes. For both the C and T concentrations, we found positive relationships between saliva and plasma. The concentrations of C and T in saliva showed clear patterns of diurnal fluctuation, whereas those in urine and feces did not. These results suggest that the salivary steroid concentrations can be regarded as good indicators of circulating steroid levels. We also developed and validated an efficient method for collecting saliva samples from cotton rope. Although rope includes inherent steroid-like compounds and may affect the accuracy of steroid measurements, our rope-washing procedures effectively removed intrinsic steroidal materials. There was a significant association between the C and T concentrations measured from saliva collected from rope licked by the chimpanzees and those measured from saliva collected directly from the mouth. Salivary T values estimated by LC/MS-MS were similar to those measured by radioimmunoassay. The results indicate the usefulness of saliva as a noninvasive steroid measure and that steroids in the saliva of chimpanzees can be accurately measured by LC-MS/MS.

  8. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  9. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  10. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  11. Confirmatory method for the determination of nitroimidazoles in milk by liquid chromatography - tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Mitrowska Kamila

    2014-12-01

    Full Text Available A multiresidue method for the determination of seven nitroimidazoles and their hydroxy metabolites in milk was developed. Milk samples were extracted with acetonitrile and cleaned up on strong cation-exchange solid phase extraction cartridges. Evaporated to dryness first, the extracts obtained were then reconstituted in 0.1% formic acid and injected onto a liquid chromatography-tandem mass spectrometer (LC-MS/MS. The separation of analytes was achieved on gradient mode using a C18 column and a mobile phase consisting of 0.1% formic acid in acetonitrile and 0.1% formic acid in water. Multiple reaction monitoring mode was set for the MS/MS with positive electrospray ionisation. For quantification, the isotope dilution method was used with isotopically labeled analogues of the target analytes. The method was evaluated entirely in accordance with EU Commission Decision 2002/657/EC and all validation criteria were in the required ranges. The method can easily detect and confirm metronidazole, dimetridazole, ronidazole, ipronidazole, and their hydroxy metabolites below the recommended concentration level of 3 μg/kg. The decision limits and detection capabilities ranged from 0.11 μg/kg to 0.22 μg/kg and from 0.19 μg/kg to 0.37 μg/kg respectively. The overall recoveries were between 96.6% and 105.2% with a good coefficient of variation, less than 8.7% under within-laboratory reproducibility conditions.

  12. Measurement of 2',3'-cyclic nucleotides by liquid chromatography-tandem mass spectrometry in cells.

    Science.gov (United States)

    Bähre, Heike; Kaever, Volkhard

    2014-08-01

    Recently, the occurrence of 2',3'-cyclic nucleoside monophosphates (2',3'-cNMPs) in addition to 3',5'-cNMPs in mammalian tissues was reported. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of four 2',3'-cyclic nucleotides, i.e., 2',3'-cAMP, 2',3'-cCMP, 2',3'-cGMP, 2',3'-cUMP, in cell samples. Chromatographic separation was achieved using a Zorbax eclipse XCB-C18 (50 mm×4.6 mm; 1.8 μm column; Agilent) connected to a QTRAP5500 system (AB Sciex) operating in positive ionization mode. Calibration curves were constructed in the range 0.41 fmol/μL to 1666.6 fmol/μL for 2',3'-cAMP, 2',3'-cCMP, and 2',3'-cGMP, and 3.3-1666.6 fmol/μL for 2',3'-cUMP, respectively, showing squared correlation coefficients >0.9992. Accuracy and inter- and intra-day precision lay within the required ranges of <20% for LLOQ and <15% for higher concentration levels. The method was applied to the analysis of nucleotides in two different cell lines (Hek293T and HuT-78). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Antibiotic toxicity and absorption in zebrafish using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10-1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf absorbed more drug than those at 6 h post-fertilization (hpf, and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish.

  14. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  15. Determination of homocitrulline in urine of patients with HHH syndrome by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Al-Dirbashi, Osama Y; Al-Hassnan, Zuhair N; Rashed, Mohamed S

    2006-12-01

    A liquid chromatography tandem mass spectrometric method is described for the analysis of homocitrulline in human urine, a key metabolite in the differential diagnosis of hyperammonemia, hyperornithinemia, homocitrullinuria (HHH) syndrome. Urine samples were prepared by mere five-fold dilution with a mixture of internal standards (2H2-citrulline and 2H3-creatinine) used for the simultaneous quantification of creatinine. Analytes were separated on a cyano column and eluted isocratically within seven min. Detection was achieved by monitoring transitions of 190 > 84 and 190 > 127 for homocitrulline, 178 > 115 for 2H2-citrulline, 114 > 44 for creatinine and 117 > 47 for 2H3-creatinine. Calibration curves were linear up to 100 micromol/L. Intraday (n = 7) and interday (n = 6) variations were less than 10%. In urine samples from three siblings confirmed to have HHH syndrome, homocitrulline levels were at 13.3 (74), 21.1 (50) and 108.2 (103) mmol/mol creatinine (micromol/L). Control values were 0-9 mmol/mol creatinine (n = 120). The current method solves specificity issues in homocitrulline determination often encountered with some ninhydrin-based systems (coelution with methionine) and some o-phthalaldehyde-based ones (coelution with taurine), and presents an attractive alternative with a relatively high throughput.

  16. Simultaneous determination of 14 β-lactam antibiotics in cosmetic products by liquid chromatography tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Jin Lan Zhang; Yan Ling Qiao; Yi Lin Wang; Zhi Rong Chen

    2011-01-01

    In this study, a simple and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established and validated to determine the 14 β-lactam antibiotics in cosmetic products, including 1 (ceftazidime), 2 (cefaclor), 3 (cefdinir), 4 (ampicillin), 5 (cefalexin), 6 (ceftezole), 7 (cefotaxim), 8 (cefradine), 9 (cefuroxime), 10 (cephazoline), 11 (cefathiamidine), 12 (cefoperazone), 13 (cafalotin), 14 (piperacillin).

  17. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-03-01

    A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability.

  18. Screening of anabolic steroids in horse urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yu, Nola H; Ho, Emmie N M; Leung, David K K; Wan, Terence S M

    2005-04-29

    Anabolic steroids have the capability of improving athletic performance and are banned substances in the Olympic games as well as in horseracing and equestrian competitions. The control of their abuse in racehorses is traditionally performed by detecting the presence of anabolic steroids and/or their metabolite(s) in urine samples using gas chromatography-mass spectrometry (GC-MS). However, this approach usually requires tedious sample processing and chemical derivatisation steps and could be very insensitive in detecting certain steroids. This paper describes a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method for the detection of anabolic steroids that are poorly covered by GC-MS. Enzyme-treated urine was processed by solid-phase extraction (SPE) using a Bond Elut Certify cartridge, followed by a base wash for further cleanup. Separation of the steroids was carried out on a reversed-phase DB-8 column using 0.1% acetic acid and methanol as the mobile phase in a gradient elution programme. The mass spectrometer for the detection of the steroids was operated in the positive electrospray ionisation (ESI) mode with multiple reaction monitoring (MRM). Urine samples fortified with 15 anabolic steroids (namely, androstadienone, 1-androstenedione, bolasterone, boldione, 4-estrenedione, gestrinone, methandrostenolone, methenolone, 17alpha-methyltestosterone, norbolethone, normethandrolone, oxandrolone, stenbolone, trenbolone and turinabol) at low ng/mL levels were consistently detected. No significant matrix interference was observed at the retention times of the targeted ion masses in blank urine samples. The method specificity, sensitivity, precision, recoveries, and the performance of the enzyme hydrolysis step were evaluated. The successful application of the method to analyse methenolone acetate administration urine samples demonstrated that the method could be effective in detecting anabolic steroids and their metabolites in horse

  19. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymati

  20. Drug screening of hair by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hegstad, S; Khiabani, H Z; Kristoffersen, L; Kunøe, N; Lobmaier, P P; Christophersen, A S

    2008-06-01

    Hair has become an important matrix for drug analysis, complementary to blood and urine as a matrix. A prolonged detection window makes hair analysis suitable for the detection of exposure to illegal and medicinal drugs for periods up to 12 months. In the present study, a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for drug screening in hair was developed and validated. To 20 mg of hair, 0.45 mL of acetonitrile/25 mM formic acid (5:95 v/v) and 50 microL of deuterated internal standards were added, and the sample was incubated in a water bath at 37 degrees C for 18 h. LC separation was achieved with a Zorbax SB-Phenyl column (2.1 x 100 mm, 3.5-microm particle). Mass detection was performed by positive ion mode electrospray LC-MS-MS and included the following drugs/metabolites: nicotine, cotinine, morphine, 6-monoacetylmorphine, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymeth-amphetamine, cocaine, benzoylecgonine, 7-aminonitrazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, oxazepam, diazepam, alprazolam, zopiclone, zolpidem, carisoprodol, meprobamate, buprenorphine, and methadone. Within- and between-assay relative standard deviations varied from 2.0% to 12% and 2.7% to 15%, respectively. The accuracies were in the range of -24% to 16%, and recoveries ranged from 25% to 100%. The LC-MS-MS method proved to be simple and robust for the determination of drugs in hair. It has been used for authentic samples in our laboratory in the past year.

  1. Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Turpeinen, U; Linko, S; Itkonen, O; Hämäläinen, E

    2008-01-01

    Commercial direct immunoassays for serum testosterone sometimes result in inaccuracies in samples from women and children, leading to misdiagnosis and inappropriate treatment. The diagnosis of male hypogonadism also requires an accurate testosterone assay method. We therefore developed a sensitive and specific stable-isotope dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for serum testosterone at the concentrations encountered in women and children. Testosterone was extracted with ether-ethyl acetate from 250 microL or 500 microL of serum. Instrumental analysis was performed on an API 2000 tandem mass spectrometer in the multiple-reaction monitoring (MRM) mode after separation on a reversed-phase column. The MRM transitions (m/z) were 289/97 for testosterone and 291/99 for d(2) testosterone. The calibration curves exhibited consistent linearity and repeatability in the range 0.2-100 nmol/L. Interassay CVs were 4.2-7.6 % at mean concentrations of testosterone of 3.3-45 nmol/L. Total measurement uncertainty (U, k = 2) was 12.9 % and 13.4 % at testosterone levels of 2.0 nmol/L and 20 nmol/L, respectively. The limit of detection was 0.05 nmol/L (signal-to-noise ratio = 3) and the overall method recovery of testosterone was 95 %. Correlation (r) with our in-house extraction RIA was 0.98 and with a commercial RIA 0.92. Reference intervals for adult males and females in age groups 18-30, 31-50, 51-70 and over 70 years were established. Sensitivity and specificity of the LC-MS/MS method offer advantages over immunoassay and make it suitable for use as a high-throughput assay in routine clinical laboratories. The high equipment costs are balanced by higher throughput together with shorter chromatographic run times.

  2. High Performance Liquid Chromatography Tandem Mass Spectrometry Assay for the Determination of Cobinamide in Pig Plasma

    Science.gov (United States)

    McCracken, Brent A.; Brittain, Matthew K.

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25–10,000 ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25 ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were ≤15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at ~60% for dicyanocobinamide and ~22% for ginsenoside Rb1, confirming that a matrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20 hours, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species. PMID:26540437

  3. Simultaneous quantification of Pacific ciguatoxins in fish blood using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mak, Yim Ling; Wu, Jia Jun; Chan, Wing Hei; Murphy, Margaret B; Lam, James C W; Chan, Leo L; Lam, Paul K S

    2013-04-01

    Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74-103 %) in fish blood. Matrix effects (6-26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34-75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP.

  4. [Determination of five pyrrolizidine alkaloids in honey by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lü, Chen; Ding, Tao; Ma, Xin; Chen, Guosong; Yuan, Fang; Wu, Bin; Shen, Chongyu; Zhang, Rui; Fei, Xiaoqing; Zhang, Xiaoyan; Chen, Lei; Li, Li

    2013-11-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of five pyrrolizidine alkaloids (PAs) (monocrotaline, senkirkine, retrorsine, seneciphylline and senecionine) in honey. The honey samples were dissolved in 0.1 mol/L hydrochloric acid solution and a strong-cation exchange column was used to purify and concentrate the target analytes. The separation of the analytes was carried out on a Phenomenex C18 column (100 mm x 4.6 mm, 2.6 microm) using the mobile phases of acetonitrile and 5 mmol/L ammonium acetate-0.1% (volume percentage) formic acid aqueous solution with gradient elution. The separated compounds were detected in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI+). The calibration curves were of good linearity in the range of 1-100 microg/L (r > 0.99). The limit of quantification of the method was 1.0 microg/kg. The average recoveries were between 73.1% to 107.1% at three spiked levels (1, 20 and 50 microg/kg) with the relative standard deviations (RSDs) in the range of 4.1% to 17.0%. The proposed method was applied to different kinds of honey from China, New Zealand, Spain and Australia. The samples included rape, vitex, sunflower, cotton, tilia tree, date, acacia, buckwheat, manuka and eucalyptus honey. Monocrotaline, senkirkine and retrorsine were not detected in the collected honey samples. However, seneciphylline and senecionine were found in most of the honey samples. The concentrations of seneciphylline and senecionine were 11.0 -31.1 microg/kg and 8.3-29.1 microg/kg, respectively.

  5. Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arafat, Tawfiq; Arafat, Basil; awad, Riad; awwad, Ahmad Abu

    2014-12-01

    A simple and sensitive liquid chromatography-tandem mass spectrometric method for quantification of loperamide in human plasma and saliva was developed and validated, and then successfully applied in pharmacokinetic clinical study to investigate and correlate bioavailability of Imodium(®) 2mg quartet tablet dose in both human plasma and saliva. Loperamide with labeled internal standard was extracted from its biological matrix by methanol as protein direct precipitant in single extraction step. Adequate chromatographic separation for analytes from plasma and saliva matrices was achieved using ACE C18 (50mm×2.1mm, 5μm) column, eluted by water/methanol/formic acid (30:70:0.1%, v/v), delivered isocratically at constant flow rate of 0.75ml/min. The method validation intends to investigate specificity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability according to European guideline, and partial validation was applied on saliva, specificity, matrix effect, recovery, sensitivity, within and between day precision and accuracy. The calibration curve was linear through the range of 20-3000pg/ml in both plasma and saliva using a 50μl sample volume. The partial validation sections outcome in saliva was so close to those in plasma. The within- and between-day precisions were all below 8.7% for plasma and below 11.4% for saliva. Accuracies ranged from 94 to 105% for both matrices. In this study, 26 healthy volunteers participated in the clinical study, and 6 of gave their saliva samples in addition to plasma at the same time schedule. The pharmacokinetic parameters of Cmax, AUC0-t and AUC0-∞, Tmax and T1/2 in both plasma and saliva were calculated and correlated.

  6. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids.

  7. Detection of stanozolol in environmental waters using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-10-01

    Full Text Available Abstract Background Owing to frequent administration of a wide range of pharmaceutical products, various environmental waters have been found to be contaminated with pharmacologically active substances. For example, stanozolol, a synthetic anabolic steroid, is frequently misused for performance enhancement as well as for illegal growth promoting purposes in veterinary practice. Previously we reported stanozolol in hair samples collected from subjects living in Budapest. For this reason we initiated this study to explore possible environmental sources of steroid contamination. The aim of this study was to develop a method to monitor stanozolol in aqueous matrices using liquid chromatography tandem mass spectrometry (LC-MS/MS. Results Liquid-liquid extraction using pentane was found to be an efficient method for the extraction of stanozolol from water samples. This was followed by direct detection using LC-MS/MS. The method was capable of detecting 0.25 pg/mL stanozolol when only 5 mL water was processed in the presence of stanozolol D3 as internal standard. Fifteen bottled waters analysed were found to be negative for stanozolol. However, three out of six samples from the Danube river, collected from December '09 to November '10, were found to contain stanozolol at concentrations up to 1.82 pg/mL. In contrast, only one sample (out of six of urban tap water from Budapest city was found to contain stanozolol, at a concentration of 1.19 pg/mL. Conclusion The method developed is efficient, rapid, reproducible, sensitive and robust for the detection of stanozolol in aqueous matrices.

  8. Anion exchange SPE and liquid chromatography-tandem mass spectrometry in GHB analysis.

    Science.gov (United States)

    Elian, Albert A; Hackett, Jeffery

    2011-12-01

    In this study, the extraction of γ-hydroxybutyrate (GHB) from urine using solid-phase extraction (SPE) is described. SPE was performed on anion exchange columns after samples of urine had been diluted with de-ionized water. After application of the diluted samples containing GHB-d(6) as an internal standard, the sorbent was washed with deionized water and methanol and dried. The GHB was eluted from the SPE column with a solvent consisting of methanol containing 6% glacial acetic acid. The eluent was collected, evaporated to dryness, and dissolved in mobile phase (100 μL) for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative multiple reaction monitoring (MRM) mode. Liquid chromatography was performed in gradient mode employing a biphenyl column and a mobile phase consisting of acetontitrile (containing 0.1% formic acid) and 0.1% aqueous formic acid. The total run time for each analysis was less than 5 min. The limits of detection/quantification for this method were determined to be 50 and 100 ng/mL, respectively. The method was found to be linear from 500 ng/mL to 10,000 ng/mL (r(2)>0.995). The recovery of GHB was found to be greater than 75%. In this report, results of authentic urine samples analyzed for GHB by this method are presented. GHB concentrations in these samples were found to be range from less than 500 ng/mL to 5110 ng/mL.

  9. Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    NA Guangshui; GU Jia; GE Linke; ZHANG Peng; WANG Zhen; LIU Chunyang; ZHANG Lin

    2011-01-01

    Among pharmaceuticals and personal care products released into the aquatic environment,antibiotics are of particular concern,because of their ubiquity and health effects.Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems,researchers have often focused on relatively few antibiotics,because of the absence of suitable analytical methods.We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters,including tetracyclines (TCs),sulfanilamides (SAs),and quinolones (QLs).The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis,using electrospray ionization (ESI) in positive mode.The SPE was performed with Oasis HLB and Oasis MCX cartridges.Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid.Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L.The precision of the method,calculated as relative standard deviation (RSD),was below 14.6% for all the compounds.The limits of detection (LODs) varied from 0.45 pg to 7.97 pg.The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning,China.Among the tested antibiotics,31 were found in coastal waters,with their concentrations between the LOD and 212.5 ng/L.These data indicate that this method is valid for analysis of antibiotics in coastal waters.The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning,and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems.

  10. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL(-1) (LOQ) to 6 ng mL(-1) for AEA and from 0.04 ng mL(-1) (LOQ) to 10 ng mL(-1) for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  11. Evaluation of allergens in propolis by ultra-performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Gardana, Claudio; Simonetti, Paolo

    2011-06-15

    The purified extract of propolis is used as a traditional remedy for the treatment of several diseases. Its beneficial activities are mainly attributed to the polyphenolic fraction. Nevertheless, propolis can cause allergic dermatitis and the sensitization rate in humans is increasing significantly mainly in younger subjects. The aim of this study was to develop and validate a selective and sensitive ultra-performance liquid chromatography tandem mass spectrometry analysis (UPLC/MS/MS) for the evaluation of the amount of caffeic acid and its esters with allergenic action in raw propolis samples and commercial formulations. The separation was carried out on a 1.7 μm C(18) BEH Shield column and the detection performed by means of electrospray ionization in negative ion mode with multiple reaction monitoring. The confirmation of formulae of the precursor and product ions was accomplished by injection into a high-resolution system (FTICR-MS) using accurate mass measurements. The error was below 1.4 ppm.The range of the standard curves was 0.5-10 μg/mL and dihydrocaffeic acid was used as internal standard (IS). The lower limit of detection (LLOD) for 3-methyl-2-butenyl-(3M2B), 3-methyl-3-butenyl-(3M3B), 2-methyl-2-butenyl-(2M2B), benzyl-(CABE), phenylethylcaffeic acid (CAPE) and for caffeic acid (CA) and the IS was 0.1 and 0.3 μg/mL, respectively. The recoveries were in the range 96-104% and the intra- and inter-day precisions were within 6.2%. In the European (n=8) and Asiatic (n=3) propolis the most abundant allergens were CABE>3M2B>CAPE>3M3B>CA>2M2B. These compounds were not found in the red (n=1) and green (n=1) Brazilian propolis. Hydroalcoholic extracts (n=6) and tablets (n=6) were analyzed by the proposed UPLC/MS/MS method. The results showed that in the commercial products CABE, 3M2B, CAPE and 3M3B were also the most abundant. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Determination of cyanuric acid residues in catfish, trout, tilapia, salmon and shrimp by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Karbiwnyk, Christine M. [Animal Drugs Research Center, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States)], E-mail: christine.karbiwnyk@fda.hhs.gov; Andersen, Wendy C.; Turnipseed, Sherri B. [Animal Drugs Research Center, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States); Storey, Joseph M.; Madson, Mark R. [Denver District Laboratory, U.S. Food and Drug Administration, P.O. Box 25087, Denver, CO 80225-0087 (United States); Miller, Keith E. [Center for Veterinary Medicine, U.S. Food and Drug Administration, 8401 Muirkirk Road, Laurel, MD 20708 (United States); Gieseker, Charles M.; Miller, Ron A.; Rummel, Nathan G.; Reimschuessel, Renate [University of Denver, Department of Chemistry and Biochemistry, Denver, CO 80208 (United States)

    2009-04-01

    In May 2007, investigators discovered that waste material from the pet food manufacturing process contaminated with melamine (MEL) and/or cyanuric acid (CYA) had been added to hog and chicken feeds. At this time, investigators also learned that adulterated wheat gluten had been used in the manufacture of aquaculture feeds. Concern that the contaminated feed had been used in aquaculture and could enter the human food supply prompted the development of a method for the determination of CYA residues in the edible tissues of fish and shrimp. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was employed as a sensitive technique for the analysis of CYA in catfish, tilapia, salmon, trout and shrimp tissue. CYA was extracted from ground fish or shrimp with an acetic acid solution, defatted with hexane, and isolated with a graphitic carbon black solid-phase extraction column. Residues were separated from matrix components using a porous graphitic carbon LC column, and then analyzed with electrospray ionization in negative ion mode on a triple quadrupole mass spectrometer. Selective reaction monitoring was performed on the [M-H]{sup -}m/z 128 ion resulting in the product ions m/z 85 and 42. Recoveries from catfish, tilapia and trout fortified with 10-100 {mu}g kg{sup -1} of CYA averaged 67% with a relative standard deviation (R.S.D.) of 18% (n = 107). The average method detection limit (MDL) for catfish, tilapia and trout is 3.5 {mu}g kg{sup -1}. An internal standard, {sup 13}C{sub 3}-labeled CYA, was used in the salmon and shrimp extractions. Average recovery of CYA from salmon was 91% (R.S.D. = 15%, n = 18) with an MDL of 7.4 {mu}g kg{sup -1}. Average recovery of CYA from shrimp was 85% (R.S.D. = 10%, n = 13) with an MDL of 3.5 {mu}g kg{sup -1}.

  13. Rapid and simultaneous quantification of levetiracetam and its carboxylic metabolite in human plasma by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Li-Ling Yeap

    Full Text Available A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN containing 1 µg/mL of internal standard (IS, diphenhydramine, then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40:60 v/v. Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.

  14. Rapid and simultaneous quantification of levetiracetam and its carboxylic metabolite in human plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Yeap, Li-Ling; Lo, Yoke-Lin

    2014-01-01

    A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV) and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN) containing 1 µg/mL of internal standard (IS, diphenhydramine), then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm) column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40:60 v/v). Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ) for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD) was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.

  15. Evaluation of propolis polyphenols absorption in humans by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Gardana, Claudio; Simonetti, Paolo; Berti, Cristiana; Pietta, Piergiorgio

    2007-01-01

    Propolis has various biological activities such as antibacterial, antiviral, antioxidant, immunostimulating and antiinflammatory, which are generally ascribed to the polyphenolic fraction. The aim of this study was to evaluate the absorption of the main polyphenols [caffeic acid (CA), pinobanksin-5methyl ether (P-5ME), pinobanksin (Pb), chrysin (C), pinocembrin (P), galangin (G), pinobanksin-3-acetate, pinobanksin esters and caffeic acid phenylethyl ester (CAPE)] from a dewaxed and standardized extract of propolis (EPID). Fifteen healthy volunteers consumed 5 mL EPID in water, corresponding to 125 mg of flavonoids. Blood samples were collected before, each hour for 8 h and 24 h after EPID intake. After deconjugation by beta-glucuronidase/sulfatase the plasma samples were analyzed by a selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method using morin as internal standard (I.S.). A kinetic profile characterized by two t(max), respectively at 1 h and about 5 h post-ingestion, was observed in all the subjects. The two peaks may be due to enterohepatic cycling. Among the various polyphenols ingested, only P-5ME, Pb, C, P and G were detected in plasma and C(max)t(1h) were 65.7 +/- 13.3, 46.5 +/- 12.7, 79.5 +/- 18.6, 168.1 +/- 16.3 and 113.7 +/- 16.8 ng/mL, respectively. These levels decreased significantly after 8 h and were no longer detectable 24 h after EPID intake. The recovery of the extraction for CA, Pb, C, P, G and I.S. from spiked plasma was 95.2 +/- 3.1, 93.1 +/- 3.6, 91 +/- 2.5, 96.4 +/- 4.2, 93.4 +/- 2.4 and 85.5 +/- 2.4%, respectively. The results of this study evidence that flavonoids from EPID are absorbed, metabolized and Pb-5ME and G seem to have apparent absorption, measured as (AUC/dose), higher than C, P and Pb.

  16. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  17. Detection of Carbapenemase-Producing Bacteria by Using an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method

    Science.gov (United States)

    Verhoeven, Paul O.; Guezzou, Salim; Fonsale, Nathalie; Aubert, Gerald

    2014-01-01

    The emergence of carbapenemase-producing bacteria poses a new challenge in the management of antibiotic therapies for patients. This report describes a new method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for rapid detection of carbapenemase activity in enterobacteria, Pseudomonas aeruginosa, and Acinetobacter baumannii. In a panel of 78 isolates, including 41 carbapenemase-producing strains, the ULPC-MS/MS assay showed 100% agreement with molecular characterization, whereas six carbapenemase-producing isolates were not detected by the modified Hodge test. PMID:24295978

  18. Screening and determination of drugs in human saliva utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Abdel-Rehim, Abbi; Abdel-Rehim, Mohamed

    2013-09-01

    This study presents a new method for collecting and handling saliva samples using an automated analytical microsyringe and microextraction by packed syringe (MEPS). The screening and determination of lidocaine in human saliva samples utilizing MEPS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were carried out. An exact volume of saliva could be collected. The MEPS C8 -cartridge could be used for 50 extractions before it was discarded. The extraction recovery was about 60%. The pharmacokinetic curve of lidocaine in saliva using MEPS-LC-MS/MS is reported.

  19. Quantitation of organophosphorus nerve agent metabolites in human urine using isotope dilution gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Driskell, W Jack; Shih, Ming; Needham, Larry L; Barr, Dana B

    2002-01-01

    An isotope dilution gas chromatography-tandem mass spectrometric (GC-MS-MS) method was developed for quantitating the urinary metabolites of the organophosphorus nerve agents sarin, soman, tabun (GA), VX, and GF. Urine samples were concentrated by codistillation with acetonitrile, derivatized by methylation with diazomethane, and analyzed by GC-MS-MS. The limits of detection were less than 4 microg/L for all the analytes except for the GA metabolite, which had a limit of detection of less than 20 microg/L.

  20. Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3....

  1. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise

    2014-01-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were......, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be used...

  2. Colostrum protein uptake in neonatal lambs examined by descriptive and quantitative liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hernandez-Castellano, Lorenzo E; Argueello, Anastasio; Almeida, Andre M

    2015-01-01

    Colostrum intake is a key factor for newborn ruminant survival because the placenta does not allow the transfer of immune components. Therefore, newborn ruminants depend entirely on passive immunity transfer from the mother to the neonate, through the suckling of colostrum. Understanding...... dodecyl sulfate-PAGE for protein separation and in-gel digestion, followed by liquid chromatography-tandem mass spectrometry of resulting tryptic peptides for protein identification. An isobaric tag for relative and absolute quantitation (iTRAQ)-based proteomics approach was subsequently used to provide...

  3. Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Ahn, Jang-Hyuk; Kwak, Byung-Man; Park, Jung-Min; Kim, Na-Kyeoung; Kim, Jin-Man

    2014-01-01

    A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mod...

  4. Development of a method for the measurement of dehydroepiandrosterone sulphate by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chadwick, C A; Owen, L J; Keevil, B G

    2005-11-01

    Dehydroepiandrosterone sulphate (DHEAS) is a steroid that is increasingly being recognized as a potential drug of abuse in many countries. This is due to its reputation as a hormone that may be able to retard the ageing process. The measurement of DHEAS is useful in the diagnosis of medical conditions such as congenital adrenal hyperplasia and polycystic ovary syndrome. Thus, a liquid chromatography-tandem mass spectrometry method has been developed to determine DHEAS concentrations in human serum. The chromatography was performed using a Waters 2795 Alliance HT LC system coupled to a Mercury Fusion-RP column fitted with a SecurityGuard column. DHEAS and the internal standard, deuterated DHEAS, both had a retention time of 1.5 min. The transition determined by the Micromass Quattro tandem mass spectrometer for DHEAS was m/z 367.3>4 96.7 and for the internal standard m/z 369.3>96.6. The method was linear up to 20 micromol/L; the lower limit of detection and the lower limit of quantitation were both 1 micromol/L. The intra- and interassay imprecision were Rad Lyphocheck QC. The measurement of DHEAS by liquid chromatography-tandem mass spectrometry is robust and has a simple sample preparation procedure with a rapid cycle time of only 4 min.

  5. Chemotaxonomic studies of nine Paris species from China based on ultra-high performance liquid chromatography tandem mass spectrometry and Fourier transform infrared spectroscopy.

    Science.gov (United States)

    Wang, Yuanzhong; Liu, Ehu; Li, Ping

    2017-03-18

    Paris species, which contain steroid saponins, have been used as herb folk medicines in Asia. In the present study, a comprehensive strategy based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Fourier transform infrared (FT-IR) spectroscopy was firstly proposed to evaluate the chemotaxonomic relationships of nine Paris species sampled from different geographical regions in China. Principle component analysis (PCA) based on FT-IR data revealed chemical similarities in term of the nine species and geographical regions, indicating the accumulation of metabolites affected by the combination of geographical factors and species. The chemotaxonomic relationships of four species supported the morphological taxonomy and implied ancestry from P. polyphylla. After high-efficiency chromatographic separation, ions trap/time-of-flight mass spectrometry (IT-TOFMS) and triple quadrupole mass spectrometry (QQQ-MS) were used to identify unknown metabolites and simultaneously determine six key compounds (polyphyllin I, II, V, VI, VII and gracillin) in Paris species, respectively. The tentative identification of 22 steroid saponins was indicative of a common biosynthetic pathway in Paris species. Phytoecdysones, gracillin and open-chain steroid saponins were considered as key precursors. According to Pearson's correlation analysis, an insignificant correlation was found between diosgenin-type and pennogenin-type saponins belonging to the same biosynthetic pathways in the current stage. Our results could provide a reasonable foundation for chemotaxonomy or further studies of Paris species.

  6. A validated assay to quantitate serotonin in lamb plasma using ultrahigh-performance liquid chromatography-tandem mass spectrometry: applications with LC/MS3.

    Science.gov (United States)

    Szeitz, András; Nguyen, Tuan-Anh T; Riggs, K Wayne; Rurak, Dan

    2014-08-01

    An ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC/MS/MS) method was developed and validated for the quantification of serotonin (5-HT) in lamb plasma using [(2)d(4)]-serotonin ([(2)d(4)]-5-HT) as an internal standard. Charcoal-stripped human plasma was used as the blank matrix during validation, and 5-HT was quantitated using selected reaction monitoring. The UHPLC/MS/MS system consisted of an Agilent 1290 Infinity ultrahigh-performance liquid chromatograph coupled with an AB SCIEX QTRAP(®) 5500 hybrid linear ion trap triple quadrupole mass spectrometer. The method was validated for accuracy, precision, linearity, lower limit of quantification (LLOQ), selectivity, and other parameters. The LLOQ was 1.0 ng/mL, requiring 100 μL of sample. The method was applied to monitor the 5-HT levels in lamb plasma after the administration of fluoxetine. Tandem mass spectrometry cubed (MS(3)) experiments were also performed to investigate the fragmentation pattern of 5-HT and [(2)d(4)]-5-HT. A liquid chromatography-MS(3) (LC/MS(3)) method was developed, and the UHPLC/MS/MS and the LC/MS(3) methods were compared for performance.

  7. Large pore dermal microdialysis and liquid chromatography-tandem mass spectroscopy shotgun proteomic analysis

    DEFF Research Database (Denmark)

    Petersen, Lars J; Sørensen, Mette A; Codrea, Marius C

    2013-01-01

    phases of the study; trauma due to implantation of the dialysis device, a post implantation steady-state period, and after induction of vasodilatation and plasma extravasation. For shotgun proteomics, the proteins were extracted and digested with trypsin. Peptides were separated by capillary and nanoflow...... HPLC systems, followed by tandem mass spectrometry (MS/MS) on a Quadrupole-TOF hybrid instrument. The MS/MS spectra were merged and mapped to a human target protein database to achieve peptide identification and protein inference. ResultsResults showed variation in protein amounts and profiles for each......, and complement factors, make up the major load of proteins in all three test conditions. ConclusionShotgun proteomics allowed the identification of more than 150 proteins in microdialysis samples from human skin. This highlights the opportunities of LC-MS/MS to study the complex molecular interactions...

  8. Identification of flavonoids of Rhodiola rosea by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Petsalo, Aleksanteri; Jalonen, Jorma; Tolonen, Ari

    2006-04-21

    Phenolic compounds from the aerial parts of medicinal plant Rhodiola rosea were identified using LC/MS experiments with time-of-flight and triple quadrupole instruments, providing accurate mass and CID fragmentation data about the compounds. Supercritical fluid extraction (SFE) was used to remove non-polar compounds from the samples, followed by liquid extraction of the flavonoids. Flavonoids were the main constituents in aerial parts of the plant, and no phenylpropanoids were detected. In addition to usual fragment ions providing the size of the attached glycosides in flavonoids, ions due to radical cleavage of glycosides were observed in the negative ion mode with relatively high collision energies. Use of these ions for elucidating the glycosylation site in the aglycone part was evaluated and was found to give some tentative information, but their use in unambiguous identification of unknown flavonoids is not recommended. Fifteen flavonoids, of which 10 were previously unreported from the plant, were identified.

  9. Ring positional differentiation of isomeric N-alkylated fluorocathinones by gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Westphal, Folker; Junge, Thomas

    2012-11-30

    In analogy to our previously published procedure for the differentiation of regioisomeric fluoroamphetamines a method was developed, to differentiate ring positional isomeric fluorocathinones by product ion spectrometry of ions generated by chemical ionization (CI) under GC-MS conditions using methane as reagent gas. N-alkylated ortho-, meta- and para-fluorocathinones could be unequivocally differentiated by product ion spectrometry of the hydrogen fluoride loss ions [M+H-HF](+) using a triple quadrupole mass spectrometer with argon as collision gas under normalized collision conditions. This method enables the differentiation of ring positional isomers of fluorocathinones even in complex mixtures and low concentrations. The applicability of the method was shown by the analysis of synthesized N-alkylated ortho-, meta- and para-fluorocathinones and seized designer drug mixtures.

  10. Liquid chromatography tandem mass spectrometry for measuring ¹³C-labeling in intermediates of the glycolysis and pentose phosphate pathway.

    Science.gov (United States)

    Cocuron, Jean-Christophe; Alonso, Ana Paula

    2014-01-01

    This chapter describes a procedure to analyze (13)C-labeled phosphorylated compounds by liquid chromatography tandem mass spectrometry. Phosphorylated compounds, intermediaries of the glycolysis and pentose phosphate pathway, are separated by anion exchange chromatography and their isotopic labeling is determined by mass spectrometry. A sensitivity in the fmole range is achieved using scheduled multiple reaction monitoring mode.

  11. Characterization of isomeric VX nerve agent adducts on albumin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saeidian, Hamid; Mirkhani, Valioallah; Mousavi Faraz, Sajjad; Taghi Naseri, Mohammad; Babri, Mehran

    2015-01-01

    This study includes the characterization of isomeric VX organophosphorus adducts on albumin in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). VX or its structural isomers were spiked into a vial containing plasma in order to obtain phosphorylated albumin. After pronase and trypsin digestion, the resulting solutions were analyzed to confirm adduct formation with the amino acid tyrosine on the albumin in human plasma. The LC-MS/MS experiments show that VX and its isomers can be attached to tyrosine on the albumin in human blood. Mass spectrometric studies revealed some interesting fragmentation pathways during the ionization process, such as ethylene, formic acid and ammonia elimination and an intermolecular electrophilic aromatic substitution reaction. The proposed mechanisms for the formation of the fragments were confirmed through the analysis of fragments of deuterated adducts.

  12. Identification of monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate in nature by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hiserodt, Richard D; Adedeji, Jide; John, T V; Dewis, Mark L

    2004-06-01

    Menthol, menthone, and other natural compounds provide a cooling effect and a minty flavor and have found wide application in chewing gum and oral care products. Monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate provide a cooling effect without the burning sensation associated with menthol. Additionally, because they do not have a distinct flavor, they can be used in applications other than mint flavors. Because these menthyl esters have not been reported in nature, we undertook to identify a natural source for these cooling compounds. Using high performance liquid chromatography-tandem mass spectrometry, monomenthyl succinate was identified in Lycium barbarum and Mentha piperita, and monomenthyl glutarate and dimenthyl glutarate were identified in Litchi chinesis. The identifications were based on the correlation of mass spectrometric and chromatographic retention time data for the menthyl esters in the extracts with authentic standards which resulted in a 99.980% confidence in the identifications.

  13. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    Directory of Open Access Journals (Sweden)

    Gabriela Peste

    2009-01-01

    Full Text Available Liquid chromatography (LC coupled with mass spectrometry (MS detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the determination of bisoprolol in human plasma samples, using metoprolol as internal standard and liquid-liquid extraction procedure. The assay has proven to be sensitive, specific and reproducible, suitable to determine the bisoprolol concentration, following a single oral administration of a 10 mg bisoprolol tablet in 22 healthy volunteers, in the bioequivalence study of Bisoprolol 10 mg coated tablets, produced by Antibiotice S.A. versus Concor 10 mg, produced by Merck.

  14. Quantification of Photocyanine in Human Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Bing-Tian Bi

    2014-01-01

    Full Text Available Photocyanine is a novel anticancer drug. Its pharmacokinetic study in cancer patients is therefore very important for choosing doses, and dosing intervals in clinical application. A rapid, selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS method was developed and validated for the determination of photocyanine in patient serum. Sample preparation involved one-step protein precipitation by adding methanol and N,N-dimethyl formamide to 0.1 mL serum. The detection was performed on a triple quadrupole tandem mass spectrometer operating in multiple reaction-monitoring (MRM mode. Each sample was chromatographed within 7 min. Linear calibration curves were obtained for photocyanine at a concentration range of 20–2000 ng/mL (r>0.995, with the lower limit of quantification (LLOQ being 20 ng/mL. The intrabatch accuracy ranged from 101.98% to 107.54%, and the interbatch accuracy varied from 100.52% to 105.62%. Stability tests showed that photocyanine was stable throughout the analytical procedure. This study is the first to utilize the HPLC-MS/MS method for the pharmacokinetic study of photocyanine in six cancer patients who had received a single dose of photocyanine (0.1 mg/kg administered intravenously.

  15. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of ε-Acetamidocaproic Acid in Rat Plasma.

    Science.gov (United States)

    Kim, Tae Hyun; Choi, Yong Seok; Choi, Young Hee; Kim, Yoon Gyoon

    2013-09-01

    A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ε-acetamidocaproic acid (AACA), the primary metabolite of zinc acexamate (ZAC), in rat plasma by using normetanephrine as an internal standard. Sample preparation involved protein precipitation using methanol. Separation was achieved on a Gemini-NX C18 column (150 mm × 2.0 mm, i.d., 3 μm particle size) using a mixture of 0.1% formic acid-water : acetonitrile (80 : 20, v/v) as the mobile phase at a flow rate of 200 μl/min. Quantification was performed on a triple quadrupole mass spectrometer employing electrospray ionization and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of AACA were linear over the concentration range of 20~5000 ng/ml in rat plasma. The coefficient of variation and relative error at four QC levels were ranged from 1.0% to 5.8% and from -8.4% to 6.6%, respectively. The present method was successfully applied for estimating the pharmacokinetic parameters of AACA following intravenous or oral administration of ZAC to rats.

  16. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.

    Science.gov (United States)

    Domingues, Diego Soares; Souza, Israel Donizeti de; Queiroz, Maria Eugênia Costa

    2015-07-01

    This study reports on the development of a rapid, selective, and sensitive column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze sixteen drugs (antidepressants, anticonvulsants, anxiolytics, and antipsychotics) in plasma samples from schizophrenic patients. The developed organic-inorganic hybrid monolithic column with cyanopropyl groups was used for the first dimension of the column-switching arrangement. This arrangement enabled online pre-concentration of the drugs (monolithic column) and their subsequent analytical separation on an XSelect SCH C18 column. The drugs were detected on a triple quadrupole tandem mass spectrometer (multiple reactions monitoring mode) with an electrospray ionization source in the positive ion mode. The developed method afforded adequate linearity for the sixteen target drugs; the coefficients of determination (R(2)) lay above 0.9932, the interassay precision had coefficients of variation lower than 6.5%, and the relative standard error values of the accuracy ranged from -14.0 to 11.8%. The lower limits of quantification in plasma samples ranged from 63 to 1250pgmL(-1). The developed method successfully analyzed the target drugs in plasma samples from schizophrenic patients for therapeutic drug monitoring (TDM).

  17. Liquid chromatography-tandem mass spectrometric assay for the T790M mutant EGFR inhibitor osimertinib (AZD9291) in human plasma.

    Science.gov (United States)

    Rood, Johannes J M; van Bussel, Mark T J; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2016-09-15

    A method for the quantitative analysis by ultra-performance liquid chromatography-tandem mass spectrometry of the highly selective irreversible covalent inhibitor of EGFR-TK, osimertinib in human plasma was developed and validated, using pazopanib as an internal standard. The validation was performed in a range from 1 to 1000ng/ml, with the lowest level corresponding to the lower limit of quantitation. Gradient elution was performed on a 1.8μm particle trifunctional bonded C18 column by 1% (v/v) formic acid in water, and acetonitrile as mobile phase. The analyte was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer after positive ionization with the heated electrospray interface. Within-day precisions ranged from 3.4 to 10.3%, and between-day precisions from 3.8 to 10.4%, accuracies were 95.5-102.8%. Plasma (either lithium heparin or sodium EDTA) pretreatment was performed by salting-out assisted liquid-liquid extraction using acetonitrile and magnesium sulfate. This method was used to analyze the osimertinib blood plasma levels of five adult patients with metastatic T790M mutated non-small cellular lung carcinoma for therapeutic drug monitoring purposes.

  18. Pharmacokinetic study of 14-(3-methylbenzylmatrine and 14-(4-methylbenzylmatrine in rat plasma using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Minjie Jiang

    Full Text Available A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS was developed and validated to determine the 14-(3-methylbenzylmatrine (3MBM and 14-(4-methylbenzylmatrine (4MBM levels in rat plasma in the present study. The analytes were separated using a C18 column (1.9 μm, 2.1 mm × 100 mm equipped with a Security Guard C18 column (5 μm, 2.1 mm × 10 mm, followed by detection via triple-quadrupole mass spectrometry using an electrospray ionization (ESI source. Sample pretreatment involved one-step protein precipitation with isopropanol:ethyl acetate (v/v, 25:75, and pseudoephedrine hydrochloride was used as an internal standard. The method was linear in the concentration range of 5-2000 ng/ml for both compounds. The intra-day and inter-day relative standard deviations (RSDs were less than 15%, and all relative errors (REs were within 15%. The proposed method enables the unambiguous identification and quantification of these two compounds in vivo. This study is the first to determine the 3MBM and 4MBM levels in rat plasma after oral administration of these compounds. These results provide a meaningful basis for evaluating the clinical applications of these medicines.

  19. Pharmacokinetic study of 14-(3-methylbenzyl)matrine and 14-(4-methylbenzyl)matrine in rat plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Minjie; Wang, Lisheng; Huang, Shulin; Xu, Liba; Hu, Chao; Jiang, Weizhe

    2015-01-01

    A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS) was developed and validated to determine the 14-(3-methylbenzyl)matrine (3MBM) and 14-(4-methylbenzyl)matrine (4MBM) levels in rat plasma in the present study. The analytes were separated using a C18 column (1.9 μm, 2.1 mm × 100 mm) equipped with a Security Guard C18 column (5 μm, 2.1 mm × 10 mm), followed by detection via triple-quadrupole mass spectrometry using an electrospray ionization (ESI) source. Sample pretreatment involved one-step protein precipitation with isopropanol:ethyl acetate (v/v, 25:75), and pseudoephedrine hydrochloride was used as an internal standard. The method was linear in the concentration range of 5-2000 ng/ml for both compounds. The intra-day and inter-day relative standard deviations (RSDs) were less than 15%, and all relative errors (REs) were within 15%. The proposed method enables the unambiguous identification and quantification of these two compounds in vivo. This study is the first to determine the 3MBM and 4MBM levels in rat plasma after oral administration of these compounds. These results provide a meaningful basis for evaluating the clinical applications of these medicines.

  20. In vivo and in vitro metabolism of aspirin eugenol ester in dog by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Shen, Youming; Liu, Xiwang; Yang, Yajun; Li, Jianyong; Ma, Ning; Li, Bing

    2015-01-01

    Aspirin eugenol ester (AEE) is a promising drug candidate for treatment of inflammation, pain and fever and prevention of cardiovascular diseases with fewer side effects than its precursor, aspirin. Investigation into its metabolic process in target animal species will help to illustrate its mechanism of action and to establish its residual mark compound to formulate its dosage. Six beagle dogs were orally given a dose of 20 mg kg(-1) of AEE and one dog was used to prepare blank liver microsomes. Their liver microsomes were prepared for in vitro study and their plasma and urine were collected for in vivo metabolic analysis using liquid chromatography tandem mass spectrometry. In this study we identified 10 metabolites, M1, M2, M3, M4, M5 in phase I and M6, M7, M8, M9, M10 in phase II. Based on the metabolites of AEE, the pathways of AEE metabolism in dog were demonstrated.

  1. Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)

    Institute of Scientific and Technical Information of China (English)

    LI Wen-lan; SUN Zhi; DU Juan

    2008-01-01

    Chinese herbal compound is playing an important role on curing human diseases. And it has been a trend that Chinese herbal compound is being used all over the world in 21 century. However, our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound. In order to give full play to the advantages of Chinese herbal compound, modern scientific and technological is used to research of Chinese herbal compound, especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS), because it is high sensitive, rapid, and obtain more information. It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound, and endow traditional Chinese medicine with modern scientific connotation.

  2. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving.

  3. Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mareck, Ute; Guddat, Sven; Schwenke, Anne;

    2012-01-01

    The determination of salbutamol and its glucuronide in human urine following the inhalative and oral administration of therapeutic doses of salbutamol preparations was performed by means of direct urine injection utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) and employing d(3......)-salbutamol and d(3)-salbutamol glucuronide as internal standards. Unconjugated salbutamol was detected in all administration study urine samples. Salbutamol concentrations following inhalation were commonly (99%) below 1000 ng/ml whereas values after oral administration frequently (48%) exceeded...... this threshold. While salbutamol glucuronide was not detected in urine samples collected after inhalation of the drug, 26 out of 82 specimens obtained after oral application contained salbutamol glucuronide with a peak value of 63 ng/ml. The percentage of salbutamol glucuronide compared to unconjugated...

  4. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China.

  5. Liquid chromatography tandem mass spectrometry applied to quantitation of the organophosphorus nerve agent VX in microdialysates from blood probes.

    Science.gov (United States)

    Stubbs, S J; Read, R W

    2010-05-15

    VX (O-ethyl-S-[2(di-isopropylamino)ethyl] methylphosphonothiolate) is a low volatility organophosphorus (OP) nerve agent and therefore the most likely route of exposure is via percutaneous absorption. Microdialysis has been used as a tool to study percutaneous poisoning by VX in the anesthetised guinea pig. A liquid chromatography tandem mass spectrometry (LC-MS-MS) method using positive electrospray ionisation (ESI) was used to quantitate VX in microdialysate samples collected from microdialysis probes, implanted into a blood vessel of anesthetised guinea pigs. The method resulted from modification of a LC-MS-MS method previously developed for the analysis of dermal microdialysates. Modification increased the sensitivity of the method, allowing quantitation of the trace levels of VX in blood microdialysates, over the range 0.002-1 ng/ml, with linear calibration. Quantitative results have been used to determine the time course of VX concentrations in the blood of guinea pigs following percutaneous poisoning.

  6. Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ordoñez, Edgar Y; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2015-02-15

    A new analytical procedure involving the use of water and a low percentage of ethanol combined to high temperature liquid chromatography-tandem mass spectrometry has been developed for the determination of nine high-intensity sweeteners in a variety of drink samples. The method permitted the analysis in 23min (including column reequilibration) and consuming only 0.85mL of a green organic solvent (ethanol). This methodology provided limits of detection (after 50-fold dilution) in the 0.05-10mg/L range, with recoveries (obtained from five different types of beverages) being in the 86-110% range and relative standard deviation values lower than 12%. Finally, the method was applied to 25 different samples purchased in Spain, where acesulfame and sucralose were the most frequently detected analytes (>50% of the samples) and cyclamate was found over the legislation limit set by the European Union in a sample and at the regulation boundary in three others.

  7. Determination of Six Pyrazole Fungicides in Grape Wine by Solid-Phase Extraction and Gas Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Shen, Yan; Li, Zhou; Ma, Qiang; Wang, Chuanxian; Chen, Xiangzhun; Miao, Qian; Han, Chao

    2016-05-18

    A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed for the first simultaneous identification and quantification of six pyrazole fungicides (furametpyr, rabenzazole, fluxapyroxad, penflufen, bixafen, and isopyrazam) in grape wine samples. The grape wine samples were first diluted with water, then purified by solid-phase extraction, and finally examined by GC-MS/MS in multiple reaction monitoring (MRM) mode. Matrix-matched calibration curves were used to correct the matrix effects. The limits of quantification (LOQs), calculated as 10 times the standard deviation, were 0.2-0.8 μg kg(-1) for the six pyrazole fungicides. The average recoveries were in the range of 74.3-94.5%, with relative standard deviations (RSDs) below 5.8%, measured at three concentration levels. The proposed method is suitable for the simultaneous determination of six pyrazole fungicides in grape wine samples.

  8. Quantitation of α-Lactalbumin by Liquid Chromatography Tandem Mass Spectrometry in Medicinal Adjuvant Lactose

    Directory of Open Access Journals (Sweden)

    Rui Yan

    2014-01-01

    Full Text Available Lactose is a widely used pharmaceutical excipient, sometimes irreplaceable. Traces of residual proteins left during production of lactose are potential allergen to body. The present paper describes a sensitive and specific LC-MS method for the determination of α-lactalbumin (α-La in lactose samples. Chromatographic separation was performed on an Acquity UPLC BEH300 C18 column (2.1×150 mm, 1.7 μm with an isocratic mobile phase consisting of water containing 0.1% TFA and acetonitrile containing 0.1% TFA (80 : 20, v/v. Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an ESI interface operating in positive ionization mode. Quantitation was performed using selected ion monitoring of m/z 2364 for α-La. The calibration curve was linear from 0.2 to 10 µg/mL. The intra- and interday precisions were less than 7.6% and the accuracy ranged from 96.4 to 104.5%. The limit of quantification (LOQ was 0.15 µg/mL and the limit of detection (LOD was 0.05 µg/mL. This method was then successfully applied to investigate 6 different lactose samples. The application can provide technical preparation for the development of specification of lactose.

  9. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp

    NARCIS (Netherlands)

    G. Chen; M. Hoptroff; X. Fei; Y. Su; H.-G. Janssen

    2013-01-01

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal st

  10. Development of a new ultra-high performance liquid chromatography - tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application

    OpenAIRE

    Vujović Maja M.; Jokanović Milan; Nikolić Goran M.

    2016-01-01

    Ambroxol hydrochloride is an expectorant agent, successfully applied in mucolytic therapy for acute and chronic bronchopulmonary diseases. The drug regulates not only mucus secretion but also showed antioxidant, anti-inflammatory and local anesthetic properties. To supplement the pharmacokinetic and toxicological studies of ambroxol, a rapid ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitation of ambroxol in rabb...

  11. Simultaneous identification of multiple β-lactamases in Acinetobacter baumannii in relation to carbapenem and ceftazidime resistance, using liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Trip, H.; Mende, K.; Majchrzykiewicz-Koehorst, J.A.; Sedee, N.J.A.; Hulst, A.G.; Jansen, H.J.; Murray, C.K.; Paauw, A.

    2015-01-01

    Shotgun proteomics using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was applied to detect β-lactamases in clinical Acinetobacter baumannii isolates. The correlation of the detection of β-lactamase proteins (rather than PCR detection of the corresponding genes) with the resistance phen

  12. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out as

  13. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp

    NARCIS (Netherlands)

    Chen, G.; Hoptroff, M.; Fei, X.; Su, Y.; Janssen, H.-G.

    2013-01-01

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal st

  14. Development of a new ultra-high performance liquid chromatography - tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application

    OpenAIRE

    Vujović Maja M.; Jokanović Milan; Nikolić Goran M.

    2016-01-01

    Ambroxol hydrochloride is an expectorant agent, successfully applied in mucolytic therapy for acute and chronic bronchopulmonary diseases. The drug regulates not only mucus secretion but also showed antioxidant, anti-inflammatory and local anesthetic properties. To supplement the pharmacokinetic and toxicological studies of ambroxol, a rapid ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitation of ambroxol in rabb...

  15. Simultaneous determination of ethanol's four types of non-oxidative metabolites in human whole blood by liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Zhang, Xinyu; Zheng, Feng; Lin, Zebin

    2017-01-01

    , but it was difficult to achieve because of their wide range of polarity. This work describes development and validation of a simple liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for 4 types of ethanol non-oxidative metabolites (ethyl glucuronide, ethyl sulfate, fatty acid ethyl esters...

  16. Use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) to detect carbapenemase production in Enterobacteriaceae by a rapid meropenem degradation assay.

    Science.gov (United States)

    Foschi, Claudio; Franza, Vincenzo; Conti, Matteo; Tamburini, Maria Vittoria; Roncarati, Greta; Cordovana, Miriam; Smirnova, Viktoria; Patrono, Daniela; Mancini, Rita; Landini, Maria Paola; Ambretti, Simone

    2015-10-01

    We evaluated the analytical performance of a liquid chromatography-tandem mass spectrometry assay to detect carbapenemase activity in a group of carbapenemase-producing Enterobacteriaceae by meropenem hydrolysis. This one-hour method showed a sensitivity of 94% and a specificity of 100%, representing a rapid and reliable option compared to conventional phenotypic assays.

  17. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  18. Multiresidue analysis of multiclass plant growth regulators in grapes by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Oulkar, Dasharath P; Banerjee, Kaushik; Ghaste, Manoj S; Ramteke, Sahadeo D; Naik, Dattatraya G; Patil, Shubhangi B; Jadhav, Manjusha R; Adsule, Pandurang G

    2011-01-01

    A selective and rapid multiresidue analysis method is presented for simultaneous estimation of 12 plant growth regulators (PGRs), namely, auxins (indol-3-acetic acid, indol-3-butyric acid, and naphthyl acetic acid), cytokinins (kinetin, zeatin, and 6-benzyladenine), gibberellic acid (GA3), abscisic acid, and synthetic compounds, namely, forchlorfenuron, paclobutrazole, isoprothiolane, and 2,4-dichlorophenoxy acetic acid (2,4-D) in bud sprouts and grape berries at the development stages of 2-3 and 6-8 mm diameters, which are the critical phases when exogenous application of PGRs may be necessary to achieve desired grape quality and yield. The sample preparation method involved extraction of plant material with acidified methanol (50%) by homogenization for 2 min at 15000 rpm. The pH of the extract was enhanced up to 6 by adding ammonium acetate, followed by homogenization and centrifugation. The supernatant extract was cleaned by SPE on an Oasis HLB cartridge (200 mg, 6 cc). The final extract was measured directly by LC/MS/MS with electrospray ionization in positive mode, except for 2,4-D, GA3, and abscisic acid extracts, which required analysis in negative mode. Quantification by multiple reaction monitoring (MRM) was supported with full-scan mass spectrometric confirmation using "information-dependent acquisition" triggered with MRM to "enhanced product ionization" mode of the hybrid quadrupole-ion trap mass analyzer. The LOQ of the test analytes varied between 1 and 10 ng/g with associated recoveries of 80-120% and precision RSD <25% (n = 8). Significant matrix-induced signal suppression was recorded when the responses for pre- and postextraction spikes of analytes were compared; this could be resolved by using matrix-matched calibration standards. The method could successfully be applied in analyzing incurred residue samples and would, therefore, be useful in precisely deciding the necessity and dose of exogenous applications of PGRs on the basis of measured

  19. Morphine brain pharmacokinetics at very low concentrations studied with accelerator mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Sadiq, Muhammad Waqas; Salehpour, Mehran; Forsgard, Niklas; Possnert, Göran; Hammarlund-Udenaes, Margareta

    2011-02-01

    Morphine has been predicted to show nonlinear blood-brain barrier transport at lower concentrations. In this study, we investigated the possibility of separating active influx of morphine from its efflux by using very low morphine concentrations and compared accelerator mass spectrometry (AMS) with liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a method for analyzing microdialysis samples. A 10-min bolus infusion of morphine, followed by a constant-rate infusion, was given to male rats (n = 6) to achieve high (250 ng/ml), medium (50 ng/ml), and low (10 ng/ml) steady-state plasma concentrations. An additional rat received infusions to achieve low (10 ng/ml), very low (2 ng/ml), and ultralow (0.4 ng/ml) concentrations. Unbound morphine concentrations from brain extracellular fluid and blood were sampled by microdialysis and analyzed by LC-MS/MS and AMS. The average partition coefficient for unbound drug (K(p,uu)) values for the low and medium steady-state levels were 0.22 ± 0.08 and 0.21 ± 0.05, respectively, when measured by AMS [not significant (NS); p = 0.5]. For the medium and high steady-state levels, K(p,uu) values were 0.24 ± 0.05 and 0.26 ± 0.05, respectively, when measured by LC-MS/MS (NS; p = 0.2). For the low, very low, and ultralow steady-state levels, K(p,uu) values were 0.16 ± 0.01, 0.16 ± 0.02, and 0.18 ± 0.03, respectively, when measured by AMS. The medium-concentration K(p,uu) values were, on average, 16% lower when measured by AMS than by LC-MS/MS. There were no significant changes in K(p,uu) over a 625-fold concentration range (0.4-250 ng/ml). It was not possible to separate active uptake transport from active efflux using these low concentrations. The two analytical methods provided indistinguishable results for plasma concentrations but differed by up to 38% for microdialysis samples; however, this difference did not affect our conclusions.

  20. Highly specific quantification of ergotamine in urine, blood, and hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Favretto, Donata; Frison, Giampietro; Vogliardi, Susanna; Ferrara, Santo Davide

    2007-06-01

    Ergotamine has been used for therapeutic purposes since the 1950s, usually to treat vascular headache. It is highly toxic and in large, repeated doses can produce all the symptoms of ergot poisoning. A selective and sensitive method, based on liquid chromatography-tandem mass spectrometry (LC-MS2), has been developed for quantifying ergotamine in biological fluids with use of a quick and easy sample preparation. Ergotamine and the internal standard, trideuterated lysergic acid diethylamide, were extracted from human urine, blood, and hair by means of liquid-liquid extraction at alkaline pH. Gradient elution on a cyanopropyl column was used for chromatographic separation. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method was validated and successfully applied to a case of iatrogenic ergotism resulting from the intake of ergotamine tartrate for treating headache. For the first time, ergotamine was identified and quantified in hair. The ergotamine concentrations measured were 320 pg/mL in blood, 100 pg/mL in urine, 24 pg/mg in proximal hair, and 15 pg/mg in distal hair.

  1. Quantification of citalopram or escitalopram and their demethylated metabolites in neonatal hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Frison, Giampietro; Favretto, Donata; Vogliardi, Susanna; Terranova, Claudio; Ferrara, Santo Davide

    2008-08-01

    Citalopram and escitalopram are highly selective serotonin reuptake inhibitors widely used in the treatment of depression. They exhibit adverse drug reactions and side effects, however, and the development of specific methods for their determination is of great interest in clinical and forensic toxicology. A liquid chromatography-tandem mass spectrometry method has been developed and validated for the assay of citalopram, escitalopram, and their demethylated metabolites in 10-mg hair samples. The analytes were extracted by incubation in methanol and liquid/liquid extraction with diethyl ether/dichloromethane. Gradient elution on a narrow bore C18 column was realized using clomipramine-d3 as an internal standard. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method exhibited a linear range of 25 to 2000 pg/mg, a quantification limit of 25 pg/mg for all analytes, relative standard deviations in the range of 12.10 to 9.80 (intraassay), and 13.80 to 11.78 (interassay), and accuracies (as percent recovery of the spiked standards) in the range of 90% to 110%; it was applied to the determination of citalopram and escitalopram and their metabolites in hair samples of two newborns to document their in utero exposure to the drugs. The method proved suitable for neonatal hair analysis of citalopram or escitalopram and was applied to two real cases of gestational exposure.

  2. Determination of rutin in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and application to pharmacokinetic study.

    Science.gov (United States)

    Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin

    2015-04-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study.

  3. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  4. Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Vieira, José Gilberto Henriques; Nakamura, Odete Hirata; Carvalho, Valdemir Melechko

    2014-11-01

    Salivary cortisol measurement plays an important role in the evaluation of adrenal function. Its high correlation with free serum cortisol, the easy of sampling and the limited presence of interfering steroids, generated multiple recent studies of its application, in special in the screening of adrenal hyperfunction. In this paper we present our experience in the development of a high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for salivary cortisol and cortisone measurement. For this study we used 181 saliva samples from our routine diagnostic laboratory. The HPLC-MS/MS method was based on a Waters Quattro Premier tandem mass spectrometer with an electrospray probe. After derivatization with hydroxylamine transitions monitored included cortisol and cortisone. An in-house radioimmunoassay (RIA) was used for salivary cortisol results comparison. Functional sensitivity was 24 ng/dL for cortisol and linearity from 24 to 1929 ng/dL. Saliva cortisol values obtained in the 181 samples presented a median of 52 ng/dL with 5-95% percentile of 24 and 374 ng/dL. With the RIA the results were 86, 25 and 436 ng/dL, respectively, with values for RIA being significantly higher (PCortisone measured in 159 samples showed a median of 278 ng/dL, with 5-95% percentile of 100 and 1,133 ng/dL. Correlation with cortisol values was significant (r=0.820, Pcortisone measurement and the evaluation of 11βHSD2 activity.

  5. Determination of residues of quaternary ammonium disinfectants in food products by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    van Bruijnsvoort, Michel; Rooselaar, Joop; Stern, Alfred G; Jonker, Klaas M

    2004-01-01

    A liquid chromatography-tandem mass spectrometry method has been developed for the determination of residues of alkylbenzyldimethylammonium, didecyldimethylammonium, didodecyldimethylammonium, and benzyldodecylhydroxyethylammonium compounds in various food matrixes. These quaternary ammonium compounds (QAs) are used in the food industry as disinfectants. According to the Dutch Food Law, the total mass (expressed as cetyltrimethylammonium chloride) of QAs in food products shall not exceed the legislative limit of 0.5 mg/kg. Samples were extracted by a simple salting-out procedure, using acetonitrile and sodium chloride; about 100 samples could be prepared and analyzed daily. Special care had to be taken to thoroughly homogenize samples and to avoid the use of contaminated labware. The method was validated by a procedure in compliance with EU Directive 2002/657. From the matrixes of ice cream and minced meat, recoveries of more than 95% with a relative standard deviation of about 3% were obtained by 3 different analysts (n = 54). Detection limits were in the low microg/kg range. The decision limit (CCalpha) was determined to be 0.55 mg/kg. Dairy and meat products, collected in The Netherlands, were analyzed (761 samples). In 1% of the meat samples, 2% of the ice cream and milkshake samples, and 24% of the whipped cream samples, the Dutch legislative limit was exceeded. Over 2000 injections could be performed on a single column without deterioration of the peak shapes or recoveries.

  6. Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery.

    Science.gov (United States)

    Mei, Hong; Hsieh, Yunsheng; Nardo, Cymbylene; Xu, Xiaoying; Wang, Shiyong; Ng, Kwokei; Korfmacher, Walter A

    2003-01-01

    A series of studies was performed to investigate some of the causes for matrix effects ('ion suppression' or 'ion enhancement') in bioanalytical high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assays. Previous studies have reported that matrix effects are mainly due to endogenous components in biological fluids and are a greater concern for electrospray ionization (ESI) than for atmospheric pressure chemical ionization (APCI). In this report we demonstrate that: (1) matrix effects can also be caused by exogenous materials, such as polymers contained in different brands of plastic tubes, or Li-heparin, a commonly used anticoagulant; (2) matrix effects are not only ionization mode (APCI or ESI) dependent, but also source design (Sciex, Finnigan, Micromass) dependent; and (3) for at least one vendor's design, we found the APCI mode to be more sensitive to matrix effects than the ESI mode. Based on these findings, we have proposed the following simple strategies to avoid matrix effects: (1) select the same brand of plastic tubes for processing and storing plasma samples and spiked plasma standards; (2) avoid using Li-heparin as the anticoagulant; and (3) try switching the ionization mode or switching to different mass spectrometers when matrix effects are encountered. These three strategies have allowed us to use protein precipitation and generic fast LC techniques to generate reliable LC/MS/MS data for the support of pharmacokinetic studies at the early drug discovery stage. Copyright 2002 John Wiley & Sons, Ltd.

  7. Multi-residue analysis of eight thioamphetamine designer drugs in human urine by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Nieddu, Maria; Boatto, Gianpiero; Pirisi, Maria Antonietta; Baralla, Elena

    2009-10-01

    An analytical procedure for the simultaneous determination in human urine of several thioamphetamine designer drugs (2C-T and ALEPH series) is reported. The quantitative analysis was performed by liquid chromatography/tandem mass spectrometry and has been fully validated. The mass spectrometer was operated in positive-ion, selected reaction monitoring (SRM) mode. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid-phase extraction was introduced in the method as a clean-up step. The entire method was validated for selectivity, linearity, precision and accuracy. The method turned out to be specific, sensitive, and reliable for the analysis of amphetamine derivatives in urine samples. The calibration curves were linear over the concentration range of 1 to 100 ng mL(-1) for all drugs with correlation coefficients that exceeded 0.996. The lower limits of detection (LODs) and quantification (LOQs) ranged from 1.2 to 4.9 ng mL(-1) and from 3.2 to 9.6 ng mL(-1), respectively.

  8. High Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Bimatoprost, Latanoprost and Travoprost in Eyelash Enhancing Cosmetic Serums

    Directory of Open Access Journals (Sweden)

    Emilia Marchei

    2016-02-01

    Full Text Available Most common prostaglandin analogs, bimatoprost, latanoprost and travoprost, are licensed for the reduction of elevated intraocular pressure in patients with open angle glaucoma and ocular hypertension, but their non approved use as eyelash enhancers is becoming popular, especially in patients with eyelashes hypotrichosis. A fast and sensitive high performance liquid chromatography tandem mass spectrometry method was developed for the measurement of bimatoprost, latanoprost and travoprost in cosmetic serums freely web-sold to increase eyelash length, thickness and darkness. The analytes and the internal standard (reserpine were separated by reversed phase chromatography with 5 mM ammonium acetate with 0.02% formic acid (mobile phase A and 5 mM ammonium acetate in acetonitrile/water (95/5; v/v with 0.02% formic acid (mobile phase B by gradient elution and detected with tandem mass spectrometry operated in multiple reaction monitoring mode. Linearity between 1 and 500 μg/g shows good correlation coefficients (r2 = 0.99 for all substances. Analytical recovery of analytes under investigation were always higher than 90% and intra-assay and inter-assay precision and accuracy always better than 11%. This method was successfully applied to analyze cosmetic serums freely sold on the Internet websites.

  9. [Determination of pesticide residues from seed coating reagent in agricultural products using ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Chen, Yue; Wang, Jinhua; Lu, Xiaoyu; Wang, Wanchun; Huang, Mei; Xu, Chaoyi

    2008-11-01

    An ultra performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) has been developed for the simultaneous determination of eight pesticide residues from seed coating in fruits, vegetable and grain. The sample was extracted by methanol-water (1:1, v/v) and determined by ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry in positive mode (ESI+) and multiple reaction monitoring (MRM) mode. The UPLC analyses were performed on an Acquity UPLC C18 column with gradient eluation. The utility of the method was demonstrated by the analysis of crude extracts, with no sample clean up, from soybean. The linear range was 1 - 200 microg/L. The correlation coefficients (r) were under 0.997. The average recoveries of eight pesticides in samples (from 0.006 to 1.2 mg/kg) ranged from 60% to 110%, and the relative standard deviations (RSDs) were less than 10%. The results indicate that the method is easier, faster, more sensitive, and suitable for the qualitative and quantitative confirmation of pesticide residues from seed coating reagent in fruit, vegetable and grain samples.

  10. Quantitation of protein S-glutathionylation by liquid chromatography-tandem mass spectrometry: correction for contaminating glutathione and glutathione disulfide.

    Science.gov (United States)

    Bukowski, Michael R; Bucklin, Christopher; Picklo, Matthew J

    2015-01-15

    Protein S-glutathionylation is a posttranslational modification that links oxidative stimuli to reversible changes in cellular function. Protein-glutathione mixed disulfide (PSSG) is commonly quantified by reduction of the disulfide and detection of the resultant glutathione species. This methodology is susceptible to contamination by free unreacted cellular glutathione (GSH) species, which are present in 1000-fold greater concentration. A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method was developed for quantification of glutathione and glutathione disulfide (GSSG), which was used for the determination of PSSG in biological samples. Analysis of rat liver samples demonstrated that GSH and GSSG coprecipitated with proteins similar to the range for PSSG in the sample. The use of [(13)C2,(5)N]GSH and [(13)C4,(5)N2]GSSG validated these results and demonstrated that the release of GSH from PSSG did not occur during sample preparation and analysis. These data demonstrate that GSH and GSSG contamination must be accounted for when determining PSSG content in cellular/tissue preparations. A protocol for rinsing samples to remove the adventitious glutathione species is demonstrated. The fragmentation patterns for glutathione were determined by high-resolution mass spectrometry, and candidate ions for detection of PSSG on protein and protein fragments were identified. Published by Elsevier Inc.

  11. Simultaneous quantification of amphetamine, opiates, ketamine and relative metabolites in urine for confirmatory analysis by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lin, Huei-Ru; Choi, Ka-Ian; Lin, Tzu-Chieh; Hu, Anren

    2013-06-15

    The rise in amphetamine, ketamine and opiates abuse in Taiwan has created a need for a reliable confirmatory assay. A method that combines superficially porous liquid chromatography tandem mass spectrometry (LC-MS/MS) with solid-phase extraction (SPE) was developed for the simultaneous quantification of amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, opiates, and their corresponding metabolites in urine. The total run time of the method was 6.7min including equilibration time. The method was validated in accordance with the European Commission (EC) Decision 2002/642/EC. The within- and between-day precision was below 13.6% and the accuracy ranged from -17.1% to +9.9% for all analytes. Ion suppression was observed but compensated by using deuterated internal standards. No carryover was detected and the analytes were stable at room temperature for 16h, and for 72h at 4°C, and three-thaw cycles. The method was further validated by comparison with a reference gas chromatography-mass spectrometry (GC-MS) method, using 52 authentic urine samples. The results indicated that for the target analytes studied, the LC-MS/MS analysis was as precise, accurate, and specific as the GC-MS method. In conclusion, the present LC-MS/MS method is robust and reliable, and suitable for use as a confirmation assay in the simultaneous urine drug testing and quantification of amphetamines, ketamines, and opiates.

  12. High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma

    Institute of Scientific and Technical Information of China (English)

    Abhishek Gandhi; Swati Guttikar; Priti Trivedi

    2015-01-01

    A sensitive and simultaneous liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C18 (50 mm × 4.6 mm, 2.6μm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100-20.0 ng/mL for levonorgestrel and 4.00-500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.

  13. How to identify and discriminate between the methyl quinates of chlorogenic acids by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jaiswal, Rakesh; Kuhnert, Nikolai

    2011-03-01

    The methyl esters of chlorogenic acids, methyl quinates, are widely distributed in plant materials and frequently appear as extraction artifacts in plant samples. This is the first time when liquid chromatography-tandem mass spectrometry methods have been used for the identification and characterization of the methyl quinates. For this purpose, methyl quinates of mono caffeoylquinic acids and mono feruloylquinic acids were synthesized as authentic standards. The methyl quinates of mono and diacyl chlorogenic acids have shown characteristic fragmentation pattern in their tandem mass spectra. MS(n + 1) spectra of the methyl quinates of diacyl chlorogenic acids were identical to MS(n) spectra of mono acyl derivatives. These quinates do not produce any methyl quinate peak at m/z 205 if compared with quinic acid peak at m/z 191 in negative ion mode. In the MS(n) spectra of these quinates, cinnamic acid part or cinnamoyl part was detected as a base peak in negative ion mode. The retention time, order of elution and fragmentation pattern were completely different if compared with LC-MS(n) methods developed for chlorogenic acids. These LC-MS(n) methods have been applied for the identification and regioisomeric characterization of the methyl quinates of chlorogenic acids in maté tea and woodruff (Galium odoratum). Two methyl caffeoylquinates (2 and 4) were identified as methyl 3-caffeoylquinate and methyl 5-caffeoylquinate.

  14. Quantitative determination of oxytocin receptor antagonist atosiban in rat plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kannan, Vivekanandan; Gadamsetty, Deepak; Rose, Madhankumar; Maria, Stella; Mustafa, Imran; Khedkar, Anand; Dave, Nitesh; Arumugam, Muruganandam; Iyer, Harish

    2010-05-01

    A kinetic study of atosiban was conducted following repeated intravenous administration in Wistar rats. Sample analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) following full validation of an in-house method. Eptifibatide, a cyclic peptide, was used as an internal standard (IS). The analyte and internal standard were extracted using solid phase extraction (SPE) method. Chromatographic separation was carried out using an ACE C18 5 microm 50 mm x 4.6 mm column with gradient elution. Mass spectrometric detection was performed using TSQ Quantum ultra AM. The lower limit of quantification was 0.01 microg/ml when 100 microl rat plasma was used. Plasma concentrations of atosiban were measured at 0 (pre-dose), 2, 15, 30, 45, 60, 120 min at the dosage levels of 0.125 mg/kg (low dose), 0.250 mg/kg (mid dose), and 0.500 mg/kg (high dose), respectively. Atosiban plasma concentration measured at Day 1 showed mean peak atosiban concentration (C(max)) 0.40, 0.57, 1.95 microg/ml for low, mid and high dose treated animals and mean peak concentration on Day 28 was 0.41, 0.88, 1.31microg/ml on Day 28 for low, mid and high dose treated animals.

  15. Determination of cyclovirobuxine D in human plasma by liquid chromatography tandem mass spectrometry and application in a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Ling-li Mu

    2011-10-01

    Full Text Available A sensitive and reliable method based on liquid chromatography tandem mass spectrometry (LC–MS/MS for the quantitation of cyclovirobuxine D in human plasma has been developed and validated. Sample preparation by solid phase extraction was followed by separation on a CN column with a mobile phase of methanol–water (95:5, v/v containing 0.2% formic acid. Mass spectrometric detection in the positive ion mode was carried out by selected reaction monitoring (SRM of the transitions at m/z 403.0→372.0 for cyclovirobuxine D and m/z 325.0→234.0 for citalopram (internal standard. The method was linear in the range 10–200 ng/L with LLOQ of 10 ng/L, recovery >85%, and no significant matrix effects. Intra- and inter-day precisions were all <9% with accuracies of 94.0–104.8%. The method was successfully applied to a pharmacokinetic study involving a single oral administration of a 2 mg cyclovirobuxine D tablet to twenty-two healthy Chinese volunteers.

  16. High-throughput determination of cortisol, cortisone, and melatonin in oral fluid by on-line turbulent flow liquid chromatography interfaced with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Fustinoni, Silvia; Polledri, Elisa; Mercadante, Rosa

    2013-07-15

    Cortisol, cortisone, and melatonin (CORTol, CORTone, and MELA, respectively) are hormones related to stress and sleep disorders. Their detection is relevant to epidemiological studies aimed at investigating the effects of circadian cycle disruption. The aim of this study was to develop and evaluate a high-throughput assay for the detection of CORTol, CORTone, and MELA concentrations in non-invasively collected oral fluid samples. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to measure levels of CORTol, CORTone, and MELA in oral fluid samples in the presence of deuterated analogs was optimized and validated. A 50 μL aliquot of oral fluid sample, obtained by centrifugation of a chewed swab, was purified using on-line turbulent flow liquid chromatography. Analytes were then separated using C18 reversed-phase chromatography, subjected to positive ionization using an electrospray source, then quantitated using a triple quadrupole mass detector in the selected reaction monitoring mode. Limits of quantification and linear dynamic ranges were found to be 0.55 nmol/L, 5.5 nmol/L, and 0.004 nmol/L, and up to 28 nmol/L, 277 nmol/L, and 0.43 nmol/L for CORTol, CORTone, and MELA, respectively. Inter- and intra-run precisions as relative standard deviation values were <5%, and accuracies were within 95-106% of theoretical concentrations. An evaluation of matrix effects showed that the use of deuterated analogs controlled sources of bias. Furthermore, the total analysis time per sample was 13 min, resulting in a throughput of approximately 100 samples/day. To our knowledge, this is the first automated, high-throughput assay for the simultaneous quantification of CORTol, CORTone, and MELA in oral fluid specimens. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Development of a new multi-analyte assay for the simultaneous detection of opioids in serum and other body fluids using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Eckart, K; Röhrich, J; Breitmeier, D; Ferner, M; Laufenberg-Feldmann, R; Urban, R

    2015-09-15

    A liquid chromatography-tandem mass spectrometry method using electrospray ionization in positive ionization mode was developed for the simultaneous detection of multiple opioid-type drugs in plasma. The presented assay allows the quantitative determination of alfentanil, buprenorphine, codeine, desomorphine, dextromethorphan, dextrorphan, dihydrocodeine, dihydromorphine, ethylmorphine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, naloxone, naltrexone, oxycodone, oxymorphone, pentazocine, pethidine, pholcodine, piritramide, remifentanil, sufentanil, and tramadol as well as the metabolites 6-monoacetylmorphine, bisnortilidine, morphine-3-glucuronide, morphine-6-glucuronide, naltrexol, norbuprenorphine, norfentanyl, norpethidine, nortilidine, and O-desmethyltramadol. Serum and blood samples were purified by solid-phase extraction. The analytes were separated on a phenyl-hexyl (100mm) column by formic acid/acetonitrile gradient elution using an UPLC 1290 Infinity coupled with a 6490 Triple Quadrupole mass spectrometer. The limits of detection ranged from 0.02 to 0.6ng/mL and the lower limits of quantification ranged from 0.1 to 2.0ng/mL. The calibration curves were linear between Calibration Levels 1-6 for all 35 substances. Recovery rates ranged between 51 and 88% for all compounds except alfentanil, bisnortilidine, pethidine, and morphine-3-glucuronide. The matrix effect ranged from 86% for ethylmorphine to 105% for desomorphine. Using the validation procedure proposed by the German Society of Toxicological and Forensic Chemistry, acceptable precision and accuracy data for almost all analytes were obtained. The method was successfully applied to 206 authentic serum samples provided by the palliative and intensive care units of the University Medical Center and the police authorities. Furthermore, a suspected fatal intoxication is demonstrated by an analysis of the sufentanil in post mortem body fluids and tissues.

  18. Simultaneous quantification of three active alkaloids from a traditional Chinese medicine Ramulus Mori (Sangzhi) in rat plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yang, Shuang; Wang, Baolian; Xia, Xuejun; Li, Xue; Wang, Renyun; Sheng, Li; Li, Dan; Liu, Yuling; Li, Yan

    2015-05-10

    Fagomine, 1-deoxynojirimycin (DNJ) and 1,4-dideoxy-1,4-imino-d-arabinitol (DAB) are the major bioactive constituents in the active fraction of alkaloids from the traditional Chinese medicine mulberry twig (Ramulus Mori, Chinese name Sang Zhi), which has a strong activity on α-glucosidase in vitro and in vivo. A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of DNJ, fagomine and DAB in rat plasma. Plasma samples were prepared using a simple protein precipitation by the addition of 1% volume of Tris and two volumes of methanol-acetonitrile. The analytes and internal standard (IS, miglitol) were chromatographed in an XBridge™ amide column with a gradient mobile phase of acetonitrile-water (0.1% ammonium hydroxide) at a flow rate of 0.7mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) source in positive ion mode by multiple reaction monitoring (MRM) mode. Linear detection responses were obtained for DNJ ranging from 5.00 to 5000.00ng/mL, 10.00 to 2500.00ng/mL for fagomine and DAB. The lower limits of quantification (LLOQs) were 5.00, 10.00, 10.00ng/mL for DNJ, fagomine and DAB, respectively. Intra-day and inter-day precisions (R.S.D.%) were within 10% for three analytes with accuracies (R.E.%) less than 12%. The mean recoveries of analytes were greater than 85%. All analytes were proved to be stable during the sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic study of the three alkaloids in rats after oral administration of the active fraction of alkaloids from mulberry twig.

  19. [Determination of five aflatoxins in Chinese patent medicines and medicinal herbs by immunoaffinity extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Han, Shen; Liu, Ying; Lu, Meiling; Li, Jianzhong; Wang, Jinhua

    2011-07-01

    A method for the determination of five aflatoxins (B1 , B2, G1 , G2, M1 ) in Chinese patent medicines and medicinal herbs by immunoaffinity extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed. The samples were extracted with 80% (v/v) methanol-water solution, followed by stepwise purification using an immunoaffinity column. The target compounds were then eluted with methanol. The extract was filtered then analyzed. With the gradient elution using a binary mobile phase containing of 0.1% formic acid-5 mmol/L ammonium acetate solution and methanol, the five aflatoxins were separated on an UHPLC BEH C18 column, followed by positive electrospray ionization and multi-reaction monitoring (MRM) provided by a triple-quadrupole tandem mass spectrometer. The limits of detection for the standard solution of aflatoxins ranged from 0.05-0.3 microg/L. The linear response was observed in the spiked concentration range of 0.5-100 microg/L with the correlation coefficients higher than 0.99. The spiked recoveries were within 62.3%-82.4% at the spiked levels of 1.0 microg/kg and 5.0 microg/kg for all the five aflatoxins with the relative standard deviations (RSDs) below 10% (n = 6). The developed method is sensitive, accurate, and reproducible with the reasonable recoveries, and can be applied to the determination of the 5 aflatoxins in the Chinese traditional patent medicines, medicinal herbs as well as other similar complex matrices.

  20. Simultaneous determination of 10 mycotoxins in grain by ultra-high-performance liquid chromatography-tandem mass spectrometry using ¹³C₁₅-deoxynivalenol as internal standard.

    Science.gov (United States)

    Jin, P G; Han, Z; Cai, Z X; Wu, Y J; Ren, Y P

    2010-12-01

    An ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of 10 mycotoxins in grain was developed. The selected mycotoxins were: deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol, nivalenol, fusarenon X, moniliformin, zearalenone, zearalanone, ochratoxin A and ochratoxin B. The samples were extracted with aqueous acetonitrile (84 : 16, v/v) and purified by reliable laboratory-made mixed cartridges. The analytes were separated on an Acquity UPLC HSS T3 column (100 × 2.1 mm, 1.8 µm) and eluted with a mobile phase of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90 : 10, v/v). All mycotoxins were detected with a Waters Micromass Quattro Ultima Pt tandem quadrupole mass spectrometer operating in negative electrospray ionization using multiple reaction monitoring mode. Accurate determination was achieved by employing commercial ¹³C₁₅-deoxynivalenol as internal standard, which compensated for target loss and eliminated matrix effects. The established method was further validated by determining the linearity (R² > 0.9990), average recovery (75.8-106.5%), sensitivity (limit of quantitation 0.09-8.48 µg kg⁻¹) and precision (relative standard deviation ≤ 6.9%). It was shown to be a suitable method for simultaneous determination of 10 mycotoxins in grain. Finally, a total of 69 corn samples randomly collected from eastern and northern China were analyzed. The results showed that deoxynivalenol was the most frequently detected contaminant, whilst 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol, nivalenol, zearalenone, zearalanone, fusarenon X and moniliformin also occurred frequently. Ochratoxin A and ochratoxin B were present only in trace amounts in a small number of samples.

  1. Determination of chlormequat and mepiquat residues and their dissipation rates in tomato cultivation matrices by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Hongxia; Ma, Zheng Feei; Yang, Haiyan; Kong, Lingming

    2017-09-08

    This study described the development and validation of a simple, rapid, specific and sensitive method for detecting chlormequat chloride (CQ) and mepiquat chloride (MQ) residues in tomato cultivation matrices covering soil, water, seedling samples. The dissipation rates of CQ and MQ in tomato cultivation matrices were also determined in this study. A Hydrophilic Interaction Liquid Chromatography (HILIC) column was used for chromatographic separation. A triple quadrupole mass spectrometer equipped with an electrospray ionisation source in positive ion mode by multiple reaction monitoring was used for detection. Soil samples were extracted with accelerated solvent extraction (ASE) and cleaned up with WCX phase extraction column; water samples were extracted with WCX phase extraction column; seedling samples were extracted with methanol-ammonium acetate solution. LODs and LOQs of CQ and MQ were 0.02μg/kg and 0.1μg/kg in soil samples, 0.005ng/mL and 0.02ng/mL in water samples, and 0.05μg/kg and 1.0μg/kg in seedling samples, respectively. The mean recovery rate of CQ in soil, water and seedling samples ranged from 76.98% to 111.60%. While the mean recovery rate of MQ in soil, water and seedling samples ranged from 96.90% to 105.40%. The fastest to the slowest metabolising rates of CQ and MQ were as follows: soil samples>seedling samples>water samples. In conclusion, this study provided a new potential method for detecting CQ and MQ in tomato cultivation matrices using ultra-performance liquid chromatography-tandem mass spectrometry. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids.

    Science.gov (United States)

    Raro, M; Portolés, T; Pitarch, E; Sancho, J V; Hernández, F; Garrostas, L; Marcos, J; Ventura, R; Segura, J; Pozo, O J

    2016-02-04

    The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid-liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H](+) or [M + H-2TMSOH](+) ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL(-1). Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected.

  3. A novel liquid chromatography/tandem mass spectrometry method for the quantification of glycine as biomarker in brain microdialysis and cerebrospinal fluid samples within 5min.

    Science.gov (United States)

    Voehringer, Patrizia; Fuertig, René; Ferger, Boris

    2013-11-15

    Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100μM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52μM to 3.6μM in striatal microdialysates and from 10.38μM to 36μM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies.

  4. Determination of deltamethrin residues in plant materials by liquid chromatography/tandem mass spectrometry with electrospray ionization.

    Science.gov (United States)

    Zimmer, Dieter; Philipowski, Christiane; Posner, Birgit; Gnielka, Agnes; Dirr, Edgar; Dorff, Mario

    2006-01-01

    This paper describes a selective and sensitive method that uses liquid chromatography/tandem mass spectrometry with positive electrospray ionization (ESI+) for the determination of deltamethrin in a variety of crops. Samples were extracted by conventional high-speed blending. Some samples required no further cleanup; others were cleaned up by gel permeation chromatography, strong cation-exchange cartridges, or partitioning with n-hexane. In the determinative step, the buffered neutral mobile phase, consisting of 10 mM ammonium acetate (pH 6.8) and methanol, and ESI+ provided strong ammonium adduct formation to [M+NH4]+ at m/z 523, and the multiple-reaction monitoring (MRM) transition at m/z 523/281 was used for the quantitation of deltamethrin. A second MRM transition at m/z 525/283 was used for confirmation. The limit of quantitation (LOQ) values were 0.01 mg/kg for edible materials and 0.05 mg/kg for nonedible materials. Mean overall recoveries at the LOQ and the 10-fold LOQ ranged from 73 to 96%, and the relative standard deviations were <10% for all samples materials analyzed.

  5. Study on dissolution mechanism of cortisol and cortisone from hair matrix with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Xing, Xue; Chen, Zheng; Li, Jifeng; Zhang, Jing; Deng, Huihua; Lu, Zuhong

    2013-06-05

    Hair cortisol has been used as a biomarker of chronic stress. The detected contents of hair cortisol might depend on the incubation duration in solvents for no-milled hair samples with 3-layer structure. However, there was no research on the dissolution mechanism of hair analytes. After uniform mixture, no-milled hair samples were incubated in methanol and water for the 12 different durations and milled hair was done as comparison. Hair cortisol and cortisone were determined with high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The measured concentrations of hair cortisol and cortisone showed ≥2 maxima during the entire incubation in methanol and water from 5 min to 72 h for no-milled hair. Hair cortisol concentration measured by LC-MS/MS was increased with the incubation duration. Conversely, it was not held when hair was powdered prior to the incubation in methanol. Hair cortisol and cortisone were dissolved from hair matrix through the 2-stage or multistage mechanism, which might depend on the hair 3-layer structure and its degree of damage. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Gas chromatography/tandem mass spectrometry detection of extracellular kynurenine and related metabolites in normal and lesioned rat brain.

    Science.gov (United States)

    Notarangelo, Francesca M; Wu, Hui-Qiu; Macherone, Anthony; Graham, David R; Schwarcz, Robert

    2012-02-15

    We describe here a gas chromatography-tandem mass spectrometry (GC/MS/MS) method for the sensitive and concurrent determination of extracellular tryptophan and the kynurenine pathway metabolites kynurenine, 3-hydroxykynurenine (3-HK), and quinolinic acid (QUIN) in rat brain. This metabolic cascade is increasingly linked to the pathophysiology of several neurological and psychiatric diseases. Methodological refinements, including optimization of MS conditions and the addition of deuterated standards, resulted in assay linearity to the low nanomolar range. Measured in samples obtained by striatal microdialysis in vivo, basal levels of tryptophan, kynurenine, and QUIN were 415, 89, and 8 nM, respectively, but 3-HK levels were below the limit of detection (<2 nM). Systemic injection of kynurenine (100 mg/kg, i.p.) did not affect extracellular tryptophan but produced detectable levels of extracellular 3-HK (peak after 2-3 h: ~50 nM) and raised extracellular QUIN levels (peak after 2h: ~105 nM). The effect of this treatment on QUIN, but not on 3-HK, was potentiated in the N-methyl-D-aspartate (NMDA)-lesioned striatum. Our results indicate that the novel methodology, which allowed the measurement of extracellular kynurenine and 3-HK in the brain in vivo, will facilitate studies of brain kynurenines and of the interplay between peripheral and central kynurenine pathway functions under physiological and pathological conditions.

  7. Large-scale profiling of diterpenoid glycosides from Stevia rebaudiana using ultrahigh performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Shafii, Behnaz; Vismeh, Ramin; Beaudry, Randy; Warner, Ryan; Jones, A Daniel

    2012-07-01

    The plant Stevia rebaudiana accumulates a suite of diterpenoid metabolites that are natural sweeteners finding increased use as sugar substitutes. To guide breeding of stevia plants that accumulate substances with desirable flavor in high yield, rapid and accurate methods are needed to profile these substances in plant populations. This report describes an 8-min ultrahigh performance liquid chromatography-tandem mass spectrometry method for separation and quantification of seven stevia glycosides including steviolbioside; stevioside; rebaudiosides A, B, and C; rubusoside; and dulcoside as well as aglycones steviol and isosteviol. This negative mode electrospray ionization/multiple reaction monitoring method yielded low limits of detection stevia glycosides. Stevioside and Reb A, B, and C were quantified in more than 1,100 extracts from stevia leaves as part of a large-scale profiling exercise. Leaf tissue levels in this population spanned about two orders of magnitude for stevioside (2-125 mg/g dry weight), Reb A (2.5-164 mg/g), Reb B (0.5-50 mg/g), and Reb C (1.5-125 mg/g), but levels of individual metabolites exhibited independent variation. The wide spread of metabolite levels highlights the utility and importance of performing targeted metabolic profiling for large plant populations.

  8. A liquid chromatography-tandem mass spectrometry-based method for the simultaneous determination of hydroxy sterols and bile acids.

    Science.gov (United States)

    John, Clara; Werner, Philipp; Worthmann, Anna; Wegner, Katrin; Tödter, Klaus; Scheja, Ludger; Rohn, Sascha; Heeren, Joerg; Fischer, Markus

    2014-12-01

    Recently, hydroxy sterols and bile acids have gained growing interest as they are important regulators of energy homoeostasis and inflammation. The high number of different hydroxy sterols and bile acid species requires powerful analytical tools to quantify these structurally and chemically similar analytes. Here, we introduce a liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for rapid quantification of 34 sterols (hydroxy sterols, primary, secondary bile acids as well as their taurine and glycine conjugates). Chromatographic baseline separation of isomeric hydroxy sterols and bile acids is obtained using a rugged amide embedded C18 (polar embedded) stationary phase. The current method features a simple extraction protocol validated for blood plasma, urine, gall bladder, liver, feces, and adipose tissue avoiding solid phase extraction as well as derivatization procedures. The total extraction recovery for representative analytes ranged between 58-86% in plasma, 85% in urine, 79-92% in liver, 76-98% in adipose tissue, 93-104% in feces and 62-79% in gall bladder. The validation procedure demonstrated that the calibration curves were linear over the selected concentration ranges for 97% of the analytes, with calculated coefficients of determination (R2) of greater than 0.99. A feeding study in wild type mice with a standard chow and a cholesterol-enriched Western type diet illustrated that the protocol described here provides a powerful tool to simultaneously quantify cholesterol derivatives and bile acids in metabolically active tissues and to follow the enterohepatic circulation.

  9. [Determination of 16 pesticide residues in fruits and vegetables by QuEChERS-liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wu, Yan; Jiang, Bing; Xu, Yigang; Zhao, Wei; Meng, Xiangrui; Zhou, Yuan; Yu, Jiahui; Zu, Yuangang

    2015-03-01

    A sensitive and convenient liquid chromatography-tandem mass spectrometric method was developed for the determination of 16 pesticides such as imidacloprid, prochloraz, difenoconazole, azoxystrobin, and thiamethoxam in fruits and vegetables. After compared with methanol and acetone-cyclohexane (1:2, v/v), acetonitrile was chosen as the extraction solvent. The samples were extracted by acetonitrile in high-speed homogenization. The extraction solution was cleaned up by liquid-liquid extraction, and the supernatant was collected. In this work, QuEChERS exhibited much higher efficiency than Carbon-NH2 solid-phase extraction in purification. The pigments and organic acids were removed by purge line (150 mg primary secondary amine (PSA) sorbent and 900 mg absolute magnesium sulfate), leading to the decrease of the background interferences. The average recoveries of the 16 pesticides were almost in the range of 75%-111% at the three spiked levels, and the relative standard deviations were less than 16%. The qualitative analysis and quantitative analysis were investigated by LC-MS/MS and matrix-matched calibration curves. The results showed that the method of QuEChERS combined with LC-MS/MS is rapid, accurate and sensitive for the determination of the 16 pesticide residues in fruits and vegetables.

  10. Liquid Chromatography-Tandem Mass Spectrometry Analysis of Perfluorooctane Sulfonate and Perfluorooctanoic Acid in Fish Fillet Samples

    Directory of Open Access Journals (Sweden)

    Viviana Paiano

    2012-01-01

    Full Text Available Perfluorooctane sulfonate (PFOS and perfluorooctanoic (PFOA acid are persistent contaminants which can be found in environmental and biological samples. A new and fast analytical method is described here for the analysis of these compounds in the edible part of fish samples. The method uses a simple liquid extraction by sonication, followed by a direct determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS. The linearity of the instrumental response was good, with average regression coefficients of 0.9971 and 0.9979 for PFOS and PFOA, respectively, and the coefficients of variation (CV of the method ranged from 8% to 20%. Limits of detection (LOD were 0.04 ng/g for both the analytes and recoveries were 90% for PFOS and 76% for PFOA. The method was applied to samples of homogenized fillets of wild and farmed fish from the Mediterranean Sea. Most of the samples showed little or no contamination by perfluorooctane sulfonate and perfluorooctanoic acid, and the highest concentrations detected among the fish species analyzed were, respectively, 5.96 ng/g and 1.89 ng/g. The developed analytical methodology can be used as a tool to monitor and to assess human exposure to perfluorinated compounds through sea food consumption.

  11. Detection of Yersinia pestis in environmental and food samples by intact cell immunocapture and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chenau, Jérôme; Fenaille, François; Simon, Stéphanie; Filali, Sofia; Volland, Hervé; Junot, Christophe; Carniel, Elisabeth; Becher, François

    2014-06-17

    Yersinia pestis is the causative agent of bubonic and pneumonic plague, an acute and often fatal disease in humans. In addition to the risk of natural exposure to plague, there is also the threat of a bioterrorist act, leading to the deliberate spread of the bacteria in the environment or food. We report here an immuno-liquid chromatography-tandem mass spectrometry (immuno-LC-MS/MS) method for the direct (i.e., without prior culture), sensitive, and specific detection of Y. pestis in such complex samples. In the first step, a bottom-up proteomics approach highlighted three relevant protein markers encoded by the Y. pestis-specific plasmids pFra (murine toxin) and pPla (plasminogen activator and pesticin). Suitable proteotypic peptides were thoroughly selected to monitor the three protein markers by targeted MS using the selected reaction monitoring (SRM) mode. Immunocapture conditions were optimized for the isolation and concentration of intact bacterial cells from complex samples. The immuno-LC-SRM assay has a limit of detection of 2 × 10(4) CFU/mL in milk or tap water, which compares well with those of state-of-the-art immunoassays. Moreover, we report the first direct detection of Y. pestis in soil, which could be extremely useful in confirming Y. pestis persistence in the ground.

  12. Determination of neonicotinoid insecticides and their metabolites in honey bee and honey by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gbylik-Sikorska, Malgorzata; Sniegocki, Tomasz; Posyniak, Andrzej

    2015-05-15

    The original analytical method for the simultaneous determination and confirmation of neonicotinoids insecticides (imidacloprid, clothianidin, acetamiprid, thiametoxam, thiacloprid, nitenpyram, dinotefuran) and some of their metabolites (imidacloprid guanidine, imidacloprid olefin, imidacloprid urea, desnitro-imidacloprid hydrochloride, thiacloprid-amid and acetamiprid-N-desmethyl) in honey bee and honey was developed. Preparation of honey bee samples involves the extraction with mixture of acetonitrile and ethyl acetate followed by cleaned up using the Sep-Pak Alumina N Plus Long cartridges. Honey samples were dissolved in 1% mixture of acetonitrile and ethyl acetate with addition of TEA, then extracts were cleaned up with Strata X-CW cartridges. The identity of analytes was confirmed using liquid chromatography tandem mass spectrometry. All compounds were separated on a Luna C18 column with gradient elution. The whole procedure was validated according to the requirements of SANCO 12571/2013. The average recoveries of the analytes ranged from 85.3% to 112.0%, repeatabilities were in the range of 2.8-11.2%, within-laboratory reproducibility was in the range of 3.3-14.6%, the limits of quantitation were in the range of 0.1-0.5μgkg(-1), depending of analyte and matrices. The validated method was successfully applied for the determination of clothianidin, imidacloprid and imidacloprid urea in real incurred honey bee samples and clothianidin in honey. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. [Determination of virginiamycin M1, in feeds by ultra high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Huang, Yonghui

    2011-10-01

    A comprehensive analytical method based on ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of virginiamycin M1 in feeds. The sample was extracted twice by ultrasonic extraction with ace-tonitrile-0.2% (v/v) formic acid (8:2, v/v). The chromatographic separation was achieved with a BEH C18 column and acetonitrile-0. 3% (v/v) formic acid (35: 65, v/v) as the mobile phase. The identification and quantification of the analyte were carried out on electrospray ionization MS/MS in a multiple reaction monitoring (MRM) mode. The correlation coefficient (r) of virginiamycin M1 was 0. 999 5 in the linear range of 0. 3 -226. 6 microg/L. The detection limit (S/ N = 3) and quantification limit (S/N = 10) of virginiamycin M1 were 2 microg/kg and 7 microg/kg, respectively. The average spiked recoveries were in the range of 82. 6% to 102. 7% with the relative standard deviations (RSDs) of 0.9% - 10.5%. The results demonstrate that the proposed method is simple, sensitive, repeatable and suitable for the testing of virginiamycin M, in feeds.

  14. Ultra-performance liquid chromatography-tandem mass spectrometry method for the analysis of amphetamines in plasma.

    Science.gov (United States)

    Fernández, María del Mar Ramírez; Samyn, Nele

    2011-10-01

    A fast and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the determination of amphetamines (amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, ephedrine, and p-methoxyamphetamine) in plasma has been developed and validated. Sample preparation was performed by liquid-liquid extraction using ethyl acetate. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing all analytes at the column inlet, a gradient start, with acid mobile phase consisting of 0.1% formic acid and methanol was chosen. Positive electrospray ionization MS-MS detection was performed with two multiple reaction monitoring transitions for each analyte. Deuteriumlabeled internal standards were used for five of the analytes. The limit of detection was in the range 0.25-1.25 ng/mL, and the limit of quantification was fixed at the lowest calibrator of 2.5 ng/mL for all of the compounds. The RSD values of the intra- and interassay precision and accuracy were lower than 11% at four concentration levels, including two external quality controls. No or only minor matrix effects were observed, and the extraction method presented recoveries higher than 93% for all the compounds. Total run time, including equilibration, was 12 min. The method is routinely used at the National Institute of Criminalistics and Criminology for quantitative determination of the main amphetamines in plasma from forensic and driving under the influence cases.

  15. Development of a liquid chromatography-tandem mass spectrometry method for quantitative analysis of trace d-amino acids.

    Science.gov (United States)

    Nakano, Yosuke; Konya, Yutaka; Taniguchi, Moyu; Fukusaki, Eiichiro

    2017-01-01

    d-Amino acids have recently attracted much attention in various research fields including medical, clinical and food industry due to their important biological functions that differ from l-amino acid. Most chiral amino acid separation techniques require complicated derivatization procedures in order to achieve the desirable chromatographic behavior and detectability. Thus, the aim of this research is to develop a highly sensitive analytical method for the enantioseparation of chiral amino acids without any derivatization process using liquid chromatography-tandem mass spectrometry (LC-MS/MS). By optimizing MS/MS parameters, we established a quantification method that allowed the simultaneous analysis of 18 d-amino acids with high sensitivity and reproducibility. Additionally, we applied the method to food sample (vinegar) for the validation, and successfully quantified trace levels of d-amino acids in samples. These results demonstrated the applicability and feasibility of the LC-MS/MS method as a novel, effective tool for d-amino acid measurement in various biological samples. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  16. Determination of 20 synthetic dyes in chili powders and syrup-preserved fruits by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chia-Fen Tsai

    2015-09-01

    Full Text Available A liquid chromatography/tandem mass spectrometry (LC-MS/MS method is developed to simultaneously determine 20 synthetic dyes (New Coccine, Indigo Carmine, Erythrosine, Tartrazine, Sunset Yellow FCF, Fast Green FCF, Brilliant Blue FCF, Allura Red AC, Amaranth, Dimethyl Yellow, Fast Garnet GBC, Para Red, Sudan I, Sudan II, Sudan III, Sudan IV, Sudan Orange G, Sudan Red 7B, Sudan Red B, and Sudan Red G in food samples. This method offers high sensitivity and selectivity through the selection of two fragment ion transitions under multiple reaction monitoring mode to satisfy the requirements of both quantitation and qualitation. Using LC-MS/MS, the newly developed extraction protocol used in this study is rapid and simple and does not require the use of solid-phase extraction cartridges. The linearities and recoveries of the method are observed at the concentration range of 0.10–200 μg/kg and more than 90% for all dyes, respectively. The method has been successfully applied to screen 18 commercial chili powders and six commercial syrup-preserved fruits purchased from retail establishments in Taipei City. The results show that three legal food dyes, Tartrazine, and/or Sunset Yellow FCF, and/or New Coccine, are present in some syrup-preserved fruits. Amaranth, an illegal food dye in certain countries but declared illegal in Taiwan, is found in an imported syrup-preserved fruit.

  17. Ultra-performance liquid chromatography-tandem mass spectrometric method for the determination of strychnine and brucine in mice plasma.

    Science.gov (United States)

    Liu, Yanwen; Zhu, Ronghua; Li, Huande; Yan, Miao; Lei, Yanqing

    2011-09-15

    A selective, simple and efficient method-ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for determination of two toxic alkaloids, namely strychnine and brucine in mice plasma. The UPLC separation was carried out using a 1.7 μm BEH C(18) column (50 mm × 2.1 mm) with a mobile phase consisting of methanol:0.1% formic acid (25:75, v/v), hence providing high efficiency, high resolution and excellent peak shape for the analytes and internal standard. The method was validated over the range of 2.48-496.4 ng/ml for strychnine and 2.64-528 ng/ml for brucine, respectively. Intra- and inter-day accuracy ranged from 95.0% to 107.9% for strychnine, 93.4% to 103.3% for brucine, and the precisions were within 13.8%. The extraction recoveries of both the two alkaloids exceed 81.9%. With a simple and minor sample preparation procedure and short run-time (strychnine and brucine in vivo. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Identification of stereoisomeric metabolites of meisoindigo in rat liver microsomes by achiral and chiral liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Huang, Meng; Goh, Lin Tang; Ho, Paul C

    2008-11-01

    N-methylisoindigotin, abbreviated as meisoindigo, has been a routine therapeutic agent in the clinical treatment of chronic myelogenous leukemia in China since the 1980s. However, information relevant to in vitro metabolism of meisoindigo is limited. In this study, in vitro stereoisomeric metabolites of meisoindigo in rat liver microsomes were identified for the first time by achiral and chiral liquid chromatography/tandem mass spectrometry, together with proton NMR spectroscopy and synchrotron infrared spectroscopy. The major in vitro phase I metabolites of meisoindigo were tentatively identified as stereoselective-reduced meisoindigo, which comprised a pair of (3-R, 3'-R) and (3-S, 3'-S) enantiomers with lower abundance, as well as another pair of (3-R, 3'-S) and (3-S, 3'-R) enantiomers with higher abundance. One type of minor in vitro metabolites was tentatively identified as stereoselective N-demethyl-reduced meisoindigo including a pair of (3-R, 3'-R) and (3-S, 3'-S) enantiomers, as well as one meso compound. Another type of minor in vitro metabolites was tentatively identified as both stereoselective and regioselective monohydroxyl-reduced meisoindigo. Based on the metabolite profiling, three parallel metabolic pathways of meisoindigo in rat liver microsomes were proposed.

  19. High-throughput analysis of 19 endogenous androgenic steroids by ultra-performance convergence chromatography tandem mass spectrometry.

    Science.gov (United States)

    Quanson, Jonathan L; Stander, Marietjie A; Pretorius, Elzette; Jenkinson, Carl; Taylor, Angela E; Storbeck, Karl-Heinz

    2016-09-15

    11-Oxygenated steroids such as 11-ketotestosterone and 11-ketodihydrotestosterone have recently been shown to play a putative role in the development and progression of castration resistant prostate cancer. In this study we report on the development of a high throughput ultra-performance convergence chromatography tandem mass spectrometry (UPC(2)-MS/MS) method for the analysis of thirteen 11-oxygenated and six canonical C19 steroids isolated from a cell culture matrix. Using an Acquity UPC(2) BEH 2-EP column we found that UPC(2) resulted in superior selectivity, increased chromatographic efficiency and a scattered elution order when compared to conventional reverse phase ultra-performance liquid chromatography (UPLC). Furthermore, there was a significant improvement in sensitivity (5-50 times). The lower limits of quantification ranged between 0.01-10ngmL(-1), while the upper limit of quantification was 100ngmL(-1) for all steroids. Accuracy, precision, intra-day variation, recovery, matrix effects and process efficiency were all evaluated and found to be within acceptable limits. Taken together we show that the increased power of UPC(2)-MS/MS allows the analyst to complete in vitro assays at biologically relevant concentrations for the first time and in so doing determine the routes of steroid metabolism which is vital for studies of androgen responsive cancers, such as prostate cancer, and could highlight new mechanisms of disease progression and new targets for cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Rapid and sensitive detection of carbapenemase activity in Acinetobacter baumannii using superficially porous liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lin, Huei-Ru; Hu, Anren; Lai, Meng-Jiun; Chiang, Chih-Wei; Liao, Chao-Chuan; Chang, Kai-Chih

    2016-12-01

    The emergence and spread of carbapenem-resistant Acinetobacter baumannii poses a challenge for optimizing antibiotic therapies and preventing outbreaks. Traditional phenotypic assays such as the modified Hodge test (MHT) or polymerase chain reaction (PCR)-based detection of the carbapenemase genes are time-consuming and complicated. Therefore, new approaches for the efficient detection of carbapenemase-producing A. baumannii are urgently required. In this study, we used the superficially porous liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to measure carbapenem hydrolysis in a solution spiked with test strains of A. baumannii. The rate of carbapenem hydrolysis during incubation was expressed as the ratio of the carbapenem peak area of the test A. baumannii strains to the noncarbapenemase-producing A. baumannii ATCC 17978. This method can accurately measure the carbapenem hydrolysis rate and, therefore, can effectively identify carbapenemase-producing strains within 75 minutes. A total of 112 A. baumannii strains were used in this study, including 103 clinical isolates with 68 carbapenem-resistant strains and 35 carbapenem-susceptible strains, seven ATCC strains and two selected mutants. The results of the superficially porous LC-MS/MS assay showed higher detection sensitivity compared to the results of the MHT. Our results demonstrate the ability of the former method to routinely detect carbapenemase-producing A. baumannii. Copyright © 2015. Published by Elsevier B.V.

  1. [Determination of dimethyl fumarate in leather and textiles by gas chromatography-tandem mass spectrometry with solid phase extraction].

    Science.gov (United States)

    Zhao, Yang; Qi, Xiaoxia

    2010-01-01

    An effective method for the determination of dimethyl fumarate (DMF) in leather and textiles by gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed. Samples of leather or textiles were extracted with ethyl acetate and concentrated, DMF was separated on a VF-5 ms column and analyzed by GC-MS/MS after solid phase extraction (SPE) process. The result shows that this method is sensitive, accurate and reliable. The linear relationship was perfect and the interference with background signal was further eliminated after pretreatment, SPE and GC-MS/MS analytical conditions were optimized. The average recoveries of DMF in leather and textiles at three levels ranged from 84% to 93%, the relative standard deviations (n = 6) were lower than 7.2%, the limits of detection in the range from 0.012 to 0.039 mg/kg (S/N = 3) , the correlation coefficient was 0.999 0 over the range 0.05 - 100 mg/L. It has been applied to routine determination of DMF in leather and textiles with satisfactory results.

  2. Simultaneous identification of abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hei-Hwa Lee

    2016-03-01

    Full Text Available A literature search reveals no studies concerning simultaneous identification of commonly abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry (LC–MS/MS. We developed and validated an LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine from suspected drug abusers. The instrument was operated in multiple-reaction monitoring using an electrospray ionization mode. Chromatograms were separated using an ACE5 C18 column on a gradient of acetonitrile. After liquid–liquid extraction, samples were passed through a 0.22-μm polyvinylidene difluoride filter before injection into the LC–MS/MS. The limits of quantitation ranged from 0.5 ng/mL to 31.3 ng/mL. The linearity ranged from 0.5 ng/mL to 200 ng/mL. The precision results were below 15.4% (intraday and 18.7% (interday. The intraday accuracy ranged from 85.9% to 121.0%; interday accuracy ranged from 66.1% to 128.7%. The proposed method was applied to 769 urine samples. The most common three drugs identified were ketamine, amphetamine, and opiates. The drug positive rate for one or more drugs was 79.6%. Our results demonstrate the suitability of the LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine.

  3. [Determination of rhodamine B in spices by solid phase extraction-high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yin, Feng; Ding, Zhaowei; Yang, Zhijian

    2012-07-01

    Rhodamine B (RB), as an unlawful colour, is forbidden to add into foods by Chinese government. A solid phase extraction-high performance liquid chromatography-tandem mass spectrometry (SPE-HPLC-MS/MS) method for the determination of RB in spices has been developed. The sample was extracted by acetonitrile and then centrifugated, purified and enriched with a strong positive ion exchange SPE column (Bond Elut Plexa PCX SPE column) after adding 10 mL 1% trichloroacetic acid solution. The HPLC separation was performed on a Pursuit C18 column (100 mm x 2.0 mm, 3 microm) by gradient elution with 0.1% (v/v) formic acid solution and methanol as the mobile phase. The analyte was detected by electrospray ionization in positive ion mode-MS/MS in multiple reaction monitoring (MRM) mode. The good linearity (R2 > 0.99) was obtained over the range of 0.6-6 microg/L. The limit of quantification (LOQ) for RB was 1.2 microg/kg. The average recoveries were ranged from 80% to 121% at the spiked levels of 1.197, 2.992 and 5.985 microg/L, and the relative standard deviations (RSDs) were not more than 15%. The conditions of mobile phase elution gradients, extraction solvents, and SPE columns were optimized. This method is highly selective and has weak matrix effect for qualitative and quantitative analyses of RB in spices.

  4. Accurate determination of ochratoxin A in Korean fermented soybean paste by isotope dilution-liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Ahn, Seonghee; Lee, Suyoung; Lee, Joonhee; Kim, Byungjoo

    2016-01-01

    Ochratoxin A (OTA), a naturally occurring mycotoxin, has been frequently detected in doenjang, a traditional fermented soybean paste, when it is fermented under improper conditions. Reliable screening of OTA in traditional fermented soybean paste (doenjang) is a special food-safety issue in Korea. Our laboratory, the National Metrology Institute of Korea, established an isotope dilution-liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method as a higher-order reference method to be used for SI-traceable value-assignment of OTA in certified reference materials (CRMs). (13)C20-OTA was used as an internal standard. Sample preparation conditions and LC/MS measurement parameters were optimised for this purpose. The analytical method was validated by measuring samples fortified with OTA at various levels. Repeatability and reproducibility studies showed that the ID-LC/MS/MS method is reliable and reproducible within 2% relative standard deviation. The analytical method was applied to determine OTA in various commercial doenjang products and home-made doenjang products.

  5. Identification and Validation of SAA4 as a Rheumatoid Arthritis Prescreening Marker by Liquid Chromatography Tandem-mass Spectrometry

    Directory of Open Access Journals (Sweden)

    AeEun Seok

    2017-05-01

    Full Text Available Rheumatoid arthritis (RA is a chronic autoimmune disease that progresses into systemic inflammation and joint deformity. RA diagnosis is a complicated procedure, and early diagnostic methods are insufficient. Therefore, in this study, we attempted to identify new markers to improve the accuracy of RA prescreening. e identified differentially expressed proteins (DEPs by using liquid chromatography tandem-mass spectrometry in health-prescreening sera with high rheumatoid factor (RF values, and compared the findings with those from sera with normal RF values. We identified 93 DEPs; of these, 36 were upregulated, and 57 were downregulated in high-RF sera. Pathway analysis revealed that these DEPs were related to immune responses. Additionally, four DEPs were statistically analyzed by proteomic analysis; of these, SAA4 was significantly validated in individual enzyme-linked immunosorbent assays. Moreover, SAA4 was significantly upregulated in RA patients (n = 40, 66.43 ± 12.97 ng/mL compared with normal controls (n = 40, 4.79 ± 0.95 ng/mL and had a higher area under the curve than C-reactive protein. Thus, we identified SAA4 as a protein that was positively correlated with RF and RA. SAA4 may represent a novel prescreening marker for the diagnosis of RA.

  6. High throughput liquid chromatography-tandem mass spectrometry assay for mercapturic acids of acrolein and crotonaldehyde in cigarette smokers' urine.

    Science.gov (United States)

    Carmella, Steven G; Chen, Menglan; Zarth, Adam; Hecht, Stephen S

    2013-09-15

    3-Hydroxypropylmercapturic acid (3-HPMA) and 3-hydroxy-1-methylpropylmercapturic acid (HMPMA) are urinary metabolites of the toxicants acrolein and crotonaldehyde, respectively. Virtually all human urine samples contain these metabolites, resulting from the action of glutathione-S-transferases on acrolein and crotonaldehyde, which are lipid peroxidation products, environmental and dietary contaminants, and constituents of cigarette smoke. We have developed a high throughput liquid chromatography-tandem mass spectrometry method for quantitative analysis of 3-HPMA and HMPMA in large numbers of small urine samples, as would be required in molecular epidemiology and clinical studies relating levels of these metabolites to cancer risk. Solid-phase extraction on mixed mode reverse phase-anion exchange 96-well plates provided sufficient purification for LC-MS/MS analysis, which was performed by auto-injection using a 96-well format, and resulted in clean, readily interpretable chromatograms, with detection limits of 4.5pmol/mL urine for 3-HPMA and 3.5pmol/mL urine for HMPMA. Accuracy was 92% for 3-HPMA and 97% for HMPMA while inter-day precision was 9.1% (coefficient of variation) for 3-HPMA and 11.0% for HMPMA. The method was applied to more than 2600 urine samples from smokers; mean levels of 3-HPMA and HMPMA were 4800±5358 (S.D.)pmol/mL and 3302±3341pmol/mL, respectively.

  7. [Determination of 12 flavonoids in tobacco leaves using ultra-high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Yong; Lin, Qian; Pang, Tao; Shi, Junli

    2015-07-01

    Flavonoids are very important secondary metabolites for tobacco plants. They are also considered as important flavor precursors for cigarettes. A method of ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was established for the simultaneous determination of 12 flavonoids in tobacco leaves. The developed method determined 10 more flavonoids compared to the traditional method. A solution of methanol-water-chloroform (5:2:2, v/v/v) was used to extract the flavonoids from tobacco leaves and remove the pigment. Instrument analysis using the UPLC-MS/MS was completed in 13 min. The method validation was performed, and the results showed that the linear correlation coefficients (r2) of all the 12 flavonoids were more than 0.99. The limits of detection and the limits of quantification were in the range of 0.3-100 μg/L and 1.2-400 μg/L, respectively. Intra-day and Inter-day reproducibilities were in the range of 3.5%-7.4% and 5.2%-11.4%, respectively. The recoveries were 81.2%-111.9%. The established method was successfully used to analyze the flavonoids of tobacco leaves of 11 varieties. Significant concentration differences of the flavonoids were found among the determined varieties. Furthermore, significant positive correlation among the flavonoids with similar chemical structures (aglycones and their related glycosides, glycosides with the same aglycone, and similar aglycones) was found using the acquired data.

  8. [Simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Gou, Xinlei; Gao, Xia; Hu, Guanghui; Chi, Haitao; Le, Shengfeng; Wang, Wei; Liu, Weili

    2014-09-01

    A sensitive method was developed for the simultaneous determination of 11 bisphenols in plastic bottled drinking water by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were freeze-dried under vacuum and then dissolved with methanol. The separation was performed on a UPLC BEH C18 column (100 mm x 2.1 mm, 1.7 μm) by using 0.1% (v/v) NH3 · H2O and methanol as mobile phases with gradient elution at a flow rate of 0.2 mL/min. The electrospray ionization (ESI) source in negative ion mode was used for the analysis of the 11 bisphenols in the multiple reaction monitoring (MRM) mode. The results verified that the standard curves for the 11 bisphenols were obtained with good correlation coefficients (R2) > 0.997 in their concentration ranges. The limits of detection (LOD, S/N = 3) for the 11 bisphenols were in the range of 0.01-1.00 μg/L. The mean recoveries for the 11 bisphenols at three spiked levels (low, middle, high) were 75.3%-102.1% with the relative standard deviations of 1.5%-8.9%. Seven plastic bottled drinking water samples were tested, and no bisphenol was found. The method is accurate, simple, rapid and feasible for the simultaneous determination of bisphenols in plastic bottled drinking water.

  9. Quantification of Iohexol in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    Science.gov (United States)

    Vicente, Faye B; Vespa, Gina; Miller, Alan; Haymond, Shannon

    2016-01-01

    Iohexol is a nonradioactive contrast medium, and its clearance from serum or urine is used to measure glomerular filtration rate (GFR). GFR is the most useful indicator of kidney function and progression of kidney disease. GFR determination using iohexol clearance is increasingly being applied in clinical practice, given its advantages over and correlation with inulin. We describe a high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method for iohexol clearance, requiring only 50 μL of serum. The sample preparation involves protein precipitation with LC/MS-grade methanol, containing ioversol as the internal standard. Samples are centrifuged and supernatant is dried under nitrogen gas at room temperature. Samples are reconstituted with mobile phase (ammonium acetate-formic acid-water). Iohexol is separated using an HPLC gradient method on a C-8 analytical column. MS/MS detection is in the multiple-reaction monitoring (MRM) mode and the transitions monitored are m/z 822.0 to m/z 804.0 and m/z 807.0 to m/z 588.0 for iohexol and ioversol, respectively.

  10. Determination of neonicotinoid insecticides and strobilurin fungicides in particle phase atmospheric samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Raina-Fulton, Renata

    2015-06-01

    A liquid chromatography-tandem mass spectrometry method has been developed for the determination of neonicotinoids and strobilurin fungicides in the particle phase fraction of atmosphere samples. Filter samples were extracted with pressurized solvent extraction, followed by a cleanup step with solid phase extraction. Method detection limits for the seven neonicotinoid insecticides and six strobilurin fungicides were in the range of 1.0-4.0 pg/m(3). Samples were collected from June to September 2013 at two locations (Osoyoos and Oliver) in the southern Okanagan Valley Agricultural Region of British Columbia, where these insecticides and fungicides are recommended for use on tree fruit crops (apples, pears, cherries, peaches, apricots) and vineyards. This work represents the first detection of acetamiprid, imidacloprid, clothianidin, kresoxim-methyl, pyraclostrobin, and trifloxystrobin in particle phase atmospheric samples collected in the Okanagan Valley in Canada. The highest particle phase atmospheric concentrations were observed for imidacloprid, pyraclostrobin, and trifloxystrobin at 360.0, 655.6, and 1908.2 pg/m(3), respectively.

  11. A new liquid chromatography-tandem mass spectrometry method for determination of parabens in human placental tissue samples.

    Science.gov (United States)

    Jiménez-Díaz, I; Vela-Soria, F; Zafra-Gómez, A; Navalón, A; Ballesteros, O; Navea, N; Fernández, M F; Olea, N; Vílchez, J L

    2011-05-15

    Endocrine disruptors are a group of organic compounds widely used, which are ubiquitous in the environment and in biological samples. The main effect of these compounds is associated with their ability to mimic or block the action of natural hormones in living organisms, including humans. Parabens (esters of p-hydroxybenzoic acid) belong to this group of compounds. In this work, we propose a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to asses the presence of parabens most commonly used in industrial applications (methyl-, ethyl-, propyl- and butyl-paraben) in samples of human placental tissue. The method involves the extraction of the analytes from the samples using ethyl acetate, followed by a clean-up step using centrifugation prior to their quantification by LC-MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the negative mode. Deuterated bisphenol A (BPA-d(16)) was used as surrogate. Found detection limits (LOD) ranged from 0.03 to 0.06 ng g(-1) and quantification limits (LOQ) from 0.1 to 0.2 ng g(-1), while inter- and intra-day variability was under 13.8%. The method was validated using standard addition calibration and a spike recovery assay. Recovery rates for spiked samples ranged from 82% to 108%. This method was satisfactorily applied for the determination of parabens in 50 placental tissue samples collected from women who live in the province of Granada (Spain).

  12. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required.

  13. Determining mycotoxins in baby foods and animal feeds using stable isotope dilution and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Kai; Wong, Jon W; Krynitsky, Alexander J; Trucksess, Mary W

    2014-09-10

    We developed a stable isotope dilution assay with liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine multiple mycotoxins in baby foods and animal feeds. Samples were fortified with [(13)C]-uniformly labeled mycotoxins as internal standards ([(13)C]-IS) and prepared by solvent extraction (50% acetonitrile in water) and filtration, followed by LC-MS/MS analysis. Mycotoxins in each sample were quantitated with the corresponding [(13)C]-IS. In general, recoveries of aflatoxins (2-100 ng/g), deoxynivalenol, fumonisins (50-2000 ng/g), ochratoxin A (20-1000 ng/kg), T-2 toxin, and zearalenone (40-2000 ng/g) in tested matrices (grain/rice/oatmeal-based formula, animal feed, dry cat/dog food) ranged from 70 to 120% with relative standard deviations (RSDs) <20%. The method provides sufficient selectivity, sensitivity, accuracy, and reproducibility to screen for aflatoxins at ng/g concentrations and deoxynivalenol and fumonisins at low μg/g concentrations in baby foods and animal feeds, without using conventional standard addition or matrix-matched calibration standards to correct for matrix effects.

  14. Detection and determination of reticuline and N-methylcoculaurine in the Annonaceae family using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kotake, Yaichiro; Okuda, Katsuhiro; Kamizono, Machiko; Matsumoto, Naoki; Tanahashi, Takao; Hara, Hiroshi; Caparros-Lefebvre, Dominique; Ohta, Shigeru

    2004-06-25

    In Guadeloupe, the French West Indies, there is a high incidence of atypical parkinsonism or progressive supranuclear palsy, and all of the investigated patients had taken herbal tea or tropical fruits of the Annonaceae family. Local inhabitants consume the fruits, and also drink tea made from the leaves. In the present study, we used liquid chromatography-tandem mass spectrometry (LC/MS/MS) with multiple reaction monitoring (MRM) to detect low-molecular-weight neurotoxic benzylisoquinoline derivatives in the Annonaceae family. We detected reticuline and N-methylcoculaurine in every Annona muricata sample examined, except for pulp and seed. They were not detected in sweetsop fruits. Norreticuline was not detected in any sample. These three compounds were toxic to SH-SY5Y neuroblastoma cells and inhibited mitochondrial respiratory complex I. It is possible that uptake of the benzylisoquinoline derivatives reticuline and N-methylcoculaurine and their accumulation in the brain may be related to the pathogenesis of the local endemic disease.

  15. Simultaneous analysis of gamma-hydroxybutyric acid and its precursors in urine using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wood, Michelle; Laloup, Marleen; Samyn, Nele; Morris, Michael R; de Bruijn, Ernst A; Maes, Robert A; Young, Michael S; Maes, Viviane; De Boeck, Gert

    2004-11-12

    We have developed a rapid method that enables the simultaneous analysis of gamma-hydroxybutyrate (GHB) and its precursors, i.e. gamma-butyrolactone (GBL) and 1,4-butanediol (1,4-BD) in urine. The method comprised a simple dilution of the urine sample, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Chromatographic separation was achieved using an Atlantis dC18 column, eluted with a mixture of formic acid and methanol. The method was linear from 1-80 mg/L for GHB and 1,4-BD and from 1-50 mg/L for GBL. The limit of quantification was 1 mg/L for all analytes. The procedure, which has a total analysis time (including sample preparation) of less than 12 min, was fully validated and applied to the analysis of 182 authentic urine samples; the results were correlated with a previously published GC-MS procedure and revealed a low prevalence of GHB-positive samples. Since no commercial immunoassay is available for the routine screening of GHB, this simple and rapid method should prove useful to meet the current increased demand for the measurement of GHB and its precursors.

  16. Quantitation of the immunodominant 33-mer peptide from α-gliadin in wheat flours by liquid chromatography tandem mass spectrometry

    Science.gov (United States)

    Schalk, Kathrin; Lang, Christina; Wieser, Herbert; Koehler, Peter; Scherf, Katharina Anne

    2017-01-01

    Coeliac disease (CD) is triggered by the ingestion of gluten proteins from wheat, rye, and barley. The 33-mer peptide from α2-gliadin has frequently been described as the most important CD-immunogenic sequence within gluten. However, from more than 890 published amino acid sequences of α-gliadins, only 19 sequences contain the 33-mer. In order to make a precise assessment of the importance of the 33-mer, it is necessary to elucidate which wheat species and cultivars contain the peptide and at which concentrations. This paper presents the development of a stable isotope dilution assay followed by liquid chromatography tandem mass spectrometry to quantitate the 33-mer in flours of 23 hexaploid modern and 15 old common (bread) wheat as well as two spelt cultivars. All flours contained the 33-mer peptide at levels ranging from 91–603 μg/g flour. In contrast, the 33-mer was absent (

  17. Colostrum protein uptake in neonatal lambs examined by descriptive and quantitative liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hernández-Castellano, Lorenzo E; Argüello, Anastasio; Almeida, André M; Castro, Noemí; Bendixen, Emøke

    2015-01-01

    Colostrum intake is a key factor for newborn ruminant survival because the placenta does not allow the transfer of immune components. Therefore, newborn ruminants depend entirely on passive immunity transfer from the mother to the neonate, through the suckling of colostrum. Understanding the importance of specific colostrum proteins has gained significant attention in recent years. However, proteomics studies of sheep colostrum and their uptake in neonate lambs has not yet been presented. The aim of this study was to describe the proteomes of sheep colostrum and lamb blood plasma, using sodium dodecyl sulfate-PAGE for protein separation and in-gel digestion, followed by liquid chromatography-tandem mass spectrometry of resulting tryptic peptides for protein identification. An isobaric tag for relative and absolute quantitation (iTRAQ)-based proteomics approach was subsequently used to provide relative quantification of how neonatal plasma protein concentrations change as an effect of colostrum intake. The results of this study describe the presence of 70 proteins in the ovine colostrum proteome. Furthermore, colostrum intake resulted in an increase of 8 proteins with important immune functions in the blood plasma of lambs. Further proteomic studies will be necessary, particularly using the selected reaction monitoring approach, to describe in detail the role of specific colostrum proteins for immune transfer to the neonate.

  18. Quantification of Salivary Arecoline, Arecaidine and N-Methylnipecotic Acid Levels in Volunteers by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Lee, Hei Hwa; Chen, Li Yao; Wang, Hui Liang; Chen, Bai Hsiun

    2015-01-01

    Relatively little is known about the metabolism of areca nut in human saliva. We here describe the simultaneous quantification of areca nut metabolites: arecoline, arecaidine and N-methylnipecotic acid in saliva samples after chewing one 5 g areca nut by using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Time courses of salivary areca nut metabolites in five adult male areca nut chewer volunteers were investigated. The limits of quantification were all 1.25 ng/mL for arecoline, arecaidine and N-methylnipecotic acid. Intra- and interday imprecisions were arecoline, arecaidine and N-methylnipecotic acid concentrations varied greatly over time between experiment individuals. Our findings suggest that arecoline might be metabolized slightly to arecaidine at 30 min after areca nut chewing and arecoline might be metabolized slightly to N-methylnipecotic acid at 25 min after areca nut chewing in the mouth. We first provide simultaneous quantification of human salivary arecoline, arecaidine and N-methylnipecotic acid levels using LC-MS-MS. This method may facilitate future research design in the pathogenic effects of areca nut exposure. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. A robust analytical method for measurement of phytoestrogens and related metabolites in serum with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Hongmei; Liao, Xiangjun; Wood, Carla M; Xiao, Chao-Wu; Feng, Yong-Lai

    2016-02-15

    A sensitive and robust method using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed for quantitation of 13 phytoestrogens and related metabolites in rat serum samples. A new type of column, the Kinetex core-shell C18 column, was applied for rapid separation of the target analytes in 10min. Two enzymes, sulfatase H-1 and gulcuronidase H-5 from Helix pomatia were compared on the efficiency of releasing the conjugated forms of the target analytes to their free forms in serum samples. The method detection limit (MDL) defined as three times the signal to noise ratio in spiked serum matrix-based solutions was in the range of 0.1-3.5ng/mL. The linear dynamic calibration was in the broad range of 0.2-500ng/mL for all target compounds. Thirty-two rat serum samples from the rats that were fed with diets containing either casein or soy protein isolates with various amounts of isoflavones for 8 weeks were analyzed for the target analytes with the developed method. Nine target analytes were detected in the serum samples. Those detectable compounds are all the metabolites of the dietary isoflavones, suggesting that the diet isoflavones were mostly metabolized to their metabolites in rat.

  20. [Simultaneous determination of eleven sex hormones in antler velvet health products by gas chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lu, Chunmei; Wang, Mingtai; Mu, Jun; Lu, Lijun; Zhou, Xiao

    2011-06-01

    A method for the simultaneous determination of 11 sex hormones in antler velvet health products by gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed. The sex hormones in antler velvet were enriched and purified by solid phase extraction and derivatized with heptafluorobutyric acid anhydride (HFBA). A DB-5 column (30 m x 0.25 mm, 0.25 microm) with nonlinear gradient program was used in GC separation. The sex hormones were determined in the multiple reaction monitoring mode. The method realized the complete separation of 11 sex hormones. The limits of detection of this method were from 1.0 to 5.0 microg/kg for the 11 sex hormones. The correlation coefficients were between 0.991 6 and 0.999 9. The recoveries were in the range of 67.4% - 99.1% with relative standard deviations (RSDs) of 2.6% - 13%. This method is accurate and reliable for the determination of the sex hormones in antler velvet health products.

  1. Determination of L-ephedrine, pseudoephedrine, and caffeine in rat plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cooper, Stephen D; Fletcher, Brenda L; Silinski, Melanie A Rehder; Brown, Sherri S; Lodge, Jon W; Fernando, Reshan A; Collins, Bradley J

    2011-07-01

    A rapid and simple liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of L-ephedrine, pseudoephedrine, and caffeine in male Fisher-344 rat plasma at nanogram-per-milliliter concentrations for use in support of toxicology studies. Only 25 μL of plasma is required, and extraction is performed using a simple, single-step protein precipitation. The method was validated over a range of 2.09 to 5460 ng/mL for L-ephedrine, 2.09 to 5050 ng/mL for pseudoephedrine and 2.03 to 5340 ng/mL for caffeine. A binary gradient elution at 0.3 mL/min was used with a Waters XBridge Phenyl (2.1 × 150 mm, 3.5 μm) column and a Waters XBridge Phenyl 2.1- × 10-mm guard column at ambient temperature. The mobile phase consisted of 10 mM ammonium acetate in water (pH 5.0) and methanol. Caffeine trimethyl-(13)C(3) was used as the internal standard. The method was evaluated for linearity, recovery, precision, accuracy, and stability, and it was successfully applied in toxicokinetic studies of ephedrine, administered alone, in combination with caffeine, and in the herbal source Ma Huang.

  2. [Determination of thiourea dioxide in lotus seed paste fillings by solid phase extraction-liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wang, Hui; Zeng, Xiwen; Chang, Xiaotu; Peng, Xinkai; Xia, Lixin; Li, Yiwei

    2014-01-01

    A method of solid phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) was developed to determine thiourea dioxide which was illegally added into lotus seed paste fillings. An amount of 0.05% (v/v) acetic acid was used to extract thiourea dioxide from fillings, and the BOND ELUT PLEXA column (60 mg/3 mL) was used as the SPE column to clean-up the extraction. Then, an Agilent HILIC column (100 mm x 2.1 mm, 3.5 microm) was applied to separate target compounds by using the mobile phases of 0.01 mol/L ammonium acetate (pH 3.5) and acetonitrile. Qualitative and quantitative analyses were operated by the multiple reaction monitoring (MRM) mode. The calibration curve showed a good linearity for the target compound in the detection range of 10 - 1 000 microg/L. The limit of detection (LOD) and limit of quantitation (LOQ) of this method were 8.0 microg/kg and 30.0 microg/kg, respectively. The recoveries were in the ranges of 75.3% - 80.7% with the RSDs of no more than 4.83%. This proposed method was rapid, highly specific and suitable for the confirmation and quantitative determination of thiourea dioxide in lotus seed paste fillings.

  3. Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mareck, Ute; Guddat, Sven; Schwenke, Anne; Beuck, Simon; Geyer, Hans; Flenker, Ulrich; Elers, Jimmi; Backer, Vibeke; Thevis, Mario; Schänzer, Wilhelm

    2011-01-01

    The determination of salbutamol and its glucuronide in human urine following the inhalative and oral administration of therapeutic doses of salbutamol preparations was performed by means of direct urine injection utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) and employing d(3)-salbutamol and d(3)-salbutamol glucuronide as internal standards. Unconjugated salbutamol was detected in all administration study urine samples. Salbutamol concentrations following inhalation were commonly (99%) below 1000 ng/ml whereas values after oral administration frequently (48%) exceeded this threshold. While salbutamol glucuronide was not detected in urine samples collected after inhalation of the drug, 26 out of 82 specimens obtained after oral application contained salbutamol glucuronide with a peak value of 63 ng/ml. The percentage of salbutamol glucuronide compared to unconjugated salbutamol was less than 3%. Authentic doping control urine samples indicating screening results for salbutamol less than 1000 ng/ml, showed salbutamol glucuronide concentrations between 2 and 6 ng/ml, whereas adverse analytical findings resulting from salbutamol levels higher than 1000 ng/ml, had salbutamol glucuronide values between 8 and 15 ng/ml. The approach enabled the rapid determination of salbutamol and its glucuronic acid conjugate in human urine and represents an alternative to existing procedures since time-consuming hydrolysis or derivatization steps were omitted. Moreover, the excretion of salbutamol glucuronide in human urine following the administration of salbutamol was proven.

  4. Development of a liquid chromatography-tandem mass spectrometry method for the determination of sulfite in food.

    Science.gov (United States)

    Robbins, Katherine S; Shah, Romina; MacMahon, Shaun; de Jager, Lowri S

    2015-06-03

    Sulfites are widely used food preservatives that can cause severe reactions in sensitive individuals. As a result, the U.S. FDA requires that sulfites be listed on the label of any food product containing >10 mg/kg (ppm) sulfite (measured as sulfur dioxide). Currently, the optimized Monier-Williams (MW) method (AOAC Official Method 990.28) is the most common approach for determining sulfite concentrations in food samples. However, this method is time-consuming and lacks specificity in certain matrices. An improved rapid, sensitive, and selective method has been developed using electrospray ionization (ESI) high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of sulfite in various food matrices. A total of 12 different types of foods were evaluated. These included dried fruits and vegetables, frozen seafood, sweeteners, and juices. The matrix is extracted with a buffered formaldehyde solution, converting free and reversibly bound sulfite to the stable formaldehyde adduct, hydroxymethylsulfonate (HMS). Extracts are prepared for injection using a C18 SPE cartridge to remove any lipophilic compounds. HMS is then separated from other matrix components using hydrophilic interaction chromatography (HILIC) and detected using multiple reaction monitoring (MRM). The method was validated at 5 concentrations in 12 food matrices. Accuracy data showed spiked recoveries ranging from 84 to 115% in representative foods. Six commercially available sulfited products were analyzed using the LC-MS/MS method, as well as the MW method, to determine if differences exist.

  5. Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwon, Sun-Myung; Shin, Ho-Sang

    2015-08-14

    A simple and convenient method to detect fluoride in biological samples was developed. This method was based on derivatization with 2-(bromomethyl)naphthalene, headspace solid phase microextraction (HS-SPME) in a vial, and gas chromatography-tandem mass spectrometric detection. The HS-SPME parameters were optimized as follows: selection of CAR/PDMS fiber, 0.5% 2-(bromomethyl)naphthalene, 250 mg/L 15-crown-5-ether as a phase transfer catalyst, extraction and derivatization temperature of 95 °C, heating time of 20 min and pH of 7.0. Under the established conditions, the lowest limits of detection were 9 and 11 μg/L in 1.0 ml of plasma and urine, respectively, and the intra- and inter-day relative standard deviation was less than 7.7% at concentrations of 0.1 and 1.0 mg/L. The calibration curve showed good linearity of plasma and urine with r=0.9990 and r=0.9992, respectively. This method is simple, amenable to automation and environmentally friendly.

  6. Determination of hepatotoxic indospicine in Australian camel meat by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tan, Eddie T T; Fletcher, Mary T; Yong, Ken W L; D'Arcy, Bruce R; Al Jassim, Rafat

    2014-02-26

    Indospicine is a hepatotoxic amino acid found in Indigofera plant spp. and is unusual in that it is not incorporated into protein but accumulates as the free amino acid in the tissues (including muscle) of animals consuming these plants. Dogs are particularly sensitive to indospicine, and secondary poisoning of dogs has occurred from the ingestion of indospicine-contaminated horse meat and more recently camel meat. In central Australia, feral camels are known to consume native Indigofera species, but the prevalence of indospicine residues in their tissues has not previously been investigated. In this study, a method was developed and validated with the use of ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to determine the level of indospicine in camel meat samples using isotopically labeled indospicine as an internal standard. UPLC-MS/MS analysis showed that the method is reproducible, with high recovery efficiency and a quantitation limit of 0.1 mg/kg. Camel meat samples from the Simpson Desert were largely contaminated (≈50%) by indospicine with levels up to 3.73 mg/kg (fresh weight) determined. However, the majority of samples (95%) contained less than 1 mg/kg indospicine.

  7. [Determination of glufosinate residue in tea by liquid chromatography-tandem mass spectrometry coupled with precolumn derivatization].

    Science.gov (United States)

    Lin, Yonghui; Liu, Zhengcai; Yang, Fang; Qiu, Yuanjin; Liu, Suzhen; Su, Zhijiao; Zhang, Qiong; Xue, Zhimin; Fang, Yu

    2012-12-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the determination of glufosinate (GLUF) residue in tea. The GLUF was extracted with water for 30 min under ultrasonication, and cleaned-up using a C18 solid phase extraction cartridge, then derived using fluorenylmethylchloroformate (FMOC-Cl) in borate buffer for 2 h. The separation was performed on a Kinetex C18 column with the mobile phases of acetonitrile and 5 mmol/L ammonium acetate aqueous solution (containing 0.2% (v/v) formic acid) in a gradient elution mode. The identification and quantification of the GLUF were carried out by MS/MS in negative electrospray ionization (ESI(-)) and multiple reaction monitoring (MRM) mode, the quantification analysis was performed by external standard method. The calibration curve showed good linearity in the range of 2.5 - 50.0 microg/L with the correlation coefficient r2 > 0.999. The limit of quantification (LOQ) was 0.10 mg/kg. The average recoveries of GLUF spiked at 0.10, 0.50 and 1.00 mg/kg levels in tea were between 61.6% and 81.4%, and the relative standard deviations (RSDs) were between 3.2% and 8.4%. The method is simple, rapid, sensitive, accurate and suitable for the confirmation and quantification of GLUF in tea.

  8. Determination of artificial sweeteners in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ordóñez, Edgar Y; Quintana, José Benito; Rodil, Rosario; Cela, Rafael

    2012-09-21

    The development and performance evaluation of an analytical method for the determination of six artificial sweeteners in environmental waters using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry are presented. To this end, different SPE alternatives have been evaluated: polymeric reversed-phase (Oasis HLB, Env+, Plexa and Strata X), and mixed-mode with either weak (Oasis WAX) or strong anionic-exchange (Oasis MAX and Plexa PAX) sorbents. Among them, reversed-phase sorbents, particularly Oasis HLB and Strata X, showed the best performance. Oasis HLB provided good trueness (recoveries: 73-112%), precision (RSD<10%) and limits of quantification (LOQ: 0.01-0.5 μg/L). Moreover, two LC separation mechanisms were evaluated: reversed-phase (RPLC) and hydrophilic interaction (HILIC), with RPLC providing better performance than HILIC. The final application of the method showed the presence of acesulfame, cyclamate, saccharin and sucralose in the wastewater and surface water samples analyzed at concentrations up to 54 μg/L.

  9. Determination of artificial sweeteners in sewage sludge samples using pressurised liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ordoñez, Edgar Y; Quintana, José Benito; Rodil, Rosario; Cela, Rafael

    2013-12-13

    An analytical method for the determination of six artificial sweeteners in sewage sludge has been developed. The procedure is based on pressurised liquid extraction (PLE) with water followed by solid-phase extraction (SPE) and subsequent liquid chromatography-tandem mass spectrometry analysis. After optimisation of the different PLE parameters, extraction with aqueous 500mM formate buffer (pH 3.5) at 80°C during a single static cycle of 21min proved to be best conditions. After a subsequent SPE, quantification limits, referred to dry weight (dw) of sewage sludge, ranged from 0.3ng/g for acesulfame (ACE) to 16ng/g for saccharin (SAC) and neohespiridine dihydrochalcone. The trueness, expressed as recovery, ranged between 72% and 105% and the precision, expressed as relative standard deviation, was lower than 16%. Moreover, the method proved its linearity up to the 2μg/g range. Finally, the described method was applied to the determination of the artificial sweeteners in primary and secondary sewage sludge from urban wastewater treatment plants. Four of the six studied artificial sweeteners (ACE, cyclamate, SAC and sucralose) were found in the samples at concentrations ranging from 17 to 628ng/g dw.

  10. Determination of pesticides and pesticide degradates in filtered water by direct aqueous-injection liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Kanagy, Leslie K.; Anderson, Cyrissa A.; Kanagy, Christopher J.

    2016-01-11

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for determination of 229 pesticides compounds (113 pesticides and 116 pesticide degradates) in filtered water samples from stream and groundwater sites. The pesticides represent a broad range of chemical classes and were selected based on criteria such as current-use intensity, probability of occurrence in streams and groundwater, and toxicity to humans or aquatic organisms. More than half of the analytes are pesticide degradates. The method involves direct injection of a 100-microliter (μL) sample onto the LC-MS/MS without any sample preparation other than filtration. Samples are analyzed with two injections, one in electrospray ionization (ESI) positive mode and one in ESI negative mode, using dynamic multiple reaction monitoring (MRM) conditions, with two MRM transitions for each analyte. The LC-MS/MS instrument parameters were optimized for highest sensitivity for the most analytes. This report describes the analytical method and presents characteristics of the method validation including bias and variability, detection levels, and holding-time studies.

  11. Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Ahn, Jang-Hyuk; Kwak, Byung-Man; Park, Jung-Min; Kim, Na-Kyeoung; Kim, Jin-Man

    2014-01-01

    A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving.

  12. Comparison of electron and chemical ionization modes for the quantification of thiols and oxidative compounds in white wines by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Thibon, Cécile; Pons, Alexandre; Mouakka, Nadia; Redon, Pascaline; Méreau, Raphaël; Darriet, Philippe

    2015-10-09

    A rapid, sensitive method for assaying volatile impact compounds in white wine was developed using gas chromatography-tandem mass spectrometry (GC-MS/MS) technology, with a triple quadrupole analyzer operating in chemical ionization and electron impact mode. This GC-MS/MS method made it possible to assay volatile thiols (3SH: 3-sulfanylhexanol, formerly 3MH; 3SHA: 3-sulfanylhexyl acetate, formerly 3MHA; 4MSP: 4-methyl-4-sulfanylpentan-2-one, formerly 4MMP; BM: benzenemethanethiol; E2SA: ethyl 2-sulfanylacetate; and 2FM: 2-furanmethanethiol) and odoriferous oxidation markers (Sotolon: 4,5-dimethyl-3-hydroxy-2(5)H-furanone, methional, and phenylacetaldehyde) simultaneously in dry white wines, comparing electron impact (EI) and chemical ionization (CI) modes. More molecular ions were produced by CI than protonated molecules, despite the greater fragmentation caused by EI. So, even using the best reactant gas giving the highest signal for thiols, EI was the best ionization mode, with the lowest detection limits. For all compounds of interest, the limits of quantification (LOQ) obtained were well below their detection thresholds (ranging from 0.5 to 8.5ng/L for volatile thiols and 65-260ng/L for oxidation markers). Recovery rates ranged from 86% to 111%, reproducibility (in terms of relative standard deviation; RSD) was below 18% in all cases, with correlation coefficients above 0.991 for all analytes. The method was successfully applied to the analysis of compounds of interest in Sauvignon Blanc wines from a single estate and ten different vintages.

  13. Occurrence of specific environmental risk factors in brain tissues of sudden infant death and sudden intrauterine unexpected death victims assessed with gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Termopoli, Veronica; Famiglini, Giorgio; Palma, Pierangela; Magrini, Laura; Cappiello, Achille

    2015-03-01

    Sudden infant death syndrome (SIDS) and sudden intrauterine unexpected death syndrome (SIUDS) are an unresolved teaser in the social-medical and health setting of modern medicine and are the result of multifactorial interactions. Recently, prenatal exposure to environmental contaminants has been associated with negative pregnancy outcomes, and verification of their presence in fetal and newborn tissues is of crucial importance. A gas chromatography-tandem mass spectrometry (MS/MS) method, using a triple quadrupole analyzer, is proposed to assess the presence of 20 organochlorine pesticides, two organophosphate pesticides, one carbamate (boscalid), and a phenol (bisphenol A) in human brain tissues. Samples were collected during autopsies of infants and fetuses that died suddenly without any evident cause. The method involves a liquid-solid extraction using n-hexane as the extraction solvent. The extracts were purified with Florisil cartridges prior to the final determination. Recovery experiments using lamb brain spiked at three different concentrations in the range of 1-50 ng g(-1) were performed, with recoveries ranging from 79 to 106%. Intraday and interday repeatability were evaluated, and relative standard deviations lower than 10% and 18%, respectively, were obtained. The selectivity and sensitivity achieved in multiple reaction monitoring mode allowed us to achieve quantification and confirmation in a real matrix at levels as low as 0.2-0.6 ng g(-1). Two MS/MS transitions were acquired for each analyte, using the Q/q ratio as the confirmatory parameter. This method was applied to the analysis of 14 cerebral cortex samples (ten SIUDS and four SIDS cases), and confirmed the presence of several selected compounds.

  14. Rapid analysis of aminoglycoside antibiotics in bovine tissues using disposable pipette extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lehotay, Steven J; Mastovska, Katerina; Lightfield, Alan R; Nuñez, Alberto; Dutko, Terry; Ng, Chilton; Bluhm, Louis

    2013-10-25

    A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pipette extraction, and analysis by a 3 min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The drug analytes include neomycin, streptomycin, dihydrosptreptomycin, and spectinomycin, which have residue tolerances in bovine in the US, and kanamicin, gentamicin, apramycin, amikacin, and hygromycin, which do not have US tolerances established in bovine tissues. Tobramycin was used as an internal standard. An additional drug, paromomycin also was validated in the method, but it was dropped during implementation due to conversion of neomycin into paromomycin. Proposed fragmentation patterns for the monitored ions of each analyte were elucidated with the aid of high resolution MS using a quadrupole-time-of-flight instrument. Recoveries from spiking experiments at regulatory levels of concern showed that all analytes averaged 70-120% recoveries in all tissues, except hygromycin averaged 61% recovery. Lowest calibrated levels were as low as 0.005 μg/g in matrix extracts, which approximately corresponded to the limit of detection for screening purposes. Drug identifications at levels cattle previously screened positive for aminoglycosides showed that this method worked well in practice. The UHPLC-MS/MS method has several advantages compared to the previous microbial inhibition screening assay, especially for distinguishing individual drugs from a mixture and improving identification of gentamicin in tissue samples.

  15. Simultaneous enantioselective determination of triadimefon and its metabolite triadimenol in edible vegetable oil by gel permeation chromatography and ultraperformance convergence chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Yao, Zhoulin; Li, Xiaoge; Miao, Yelong; Lin, Mei; Xu, Mingfei; Wang, Qiang; Zhang, Hu

    2015-11-01

    A novel, sensitive, and efficient enantioselective method for the determination of triadimefon and its metabolite triadimenol in edible vegetable oil, was developed by gel permeation chromatography and ultraperformance convergence chromatography/tandem triple quadrupole mass spectrometry. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated, and dried with nitrogen gas. The residue was redissolved by adding methanol up to a final volume of 1 mL. The analytes of six enantiomers were analyzed on Chiralpak IA-3 column (150 × 4.6 mm) using compressed liquid CO2-mixed 14 % co-solvents, comprising methanol/acetonitrile/isopropanol = 20/20/60 (v/v/v) in the mobile phase at 30 °C, and the total separation time was less than 4 min at a flow rate of 2 mL/min. Quantification was achieved using matrix-matched standard calibration curves. The overall mean recoveries for six enantiomers from vegetable oil were 90.1-97.3 %, with relative standard deviations of 0.8-5.4 % intra-day and 2.3-5.0 % inter-day at 0.5, 5, and 50 μg/kg levels. The limits of quantification were 0.5 μg/kg for all enantiomers based on five replicate extractions at the lowest fortified level in vegetable oil. Moreover, the absolute configuration of six enantiomers had been determined based on comparisons of the vibrational circular dichroism experimental spectra with the theoretical curve obtained by density functional theory calculations. Application of the proposed method to the 40 authentic vegetable oil samples from local markets suggests its potential use in enantioselective determination of triadimefon and triadimenol enantiomers. Graphical Abstract Chemical structures and UPC(2)-MS/MS separation chromatograms of triadimefon and triadimenol.

  16. Graphene based solid phase extraction combined with ultra high performance liquid chromatography-tandem mass spectrometry for carbamate pesticides analysis in environmental water samples.

    Science.gov (United States)

    Shi, Zhihong; Hu, Junda; Li, Qi; Zhang, Shulan; Liang, Yuhuan; Zhang, Hongyi

    2014-08-15

    In this paper, graphene, a new sorbent material, was synthesized and used for solid-phase extraction (SPE) of the six carbamate pesticides (pirimicarb, baygon, carbaryl, isoprocarb, baycarb and diethofencarb) in environmental water samples. The target analytes can be extracted on the graphene-packed SPE cartridge, and then eluted with acetone. The eluate was collected and dried by high purity nitrogen gas at room temperature. 1mL of 20% (v/v) acetonitrile aqueous solution was used to redissolve the residue. The final sample solution was analyzed by ultra performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC-MS/MS) system. Under optimum conditions, good linearity was obtained for the carbamates with correlation coefficient in the range of 0.9992-0.9998. The limits of detection (S/N=3) for the six carbamate pesticides were in the range of 0.5-6.9ngL(-1). Relative standard deviations (RSD) for five replicate determinations were below 5.54%. RSD values for cartridge-to-cartridge precision (n=7) were in the range of 1.27-8.13%. After proper regeneration, the graphene-packed SPE cartridge could be re-used over 100 times for standard solution without significant loss of performance. The enrichment factors for the target analytes were in the range of 34.2-51.7. The established method has been successfully applied to the determination of carbamate pesticide residues in environmental water samples such as river water, well water and lake water. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Fast determination of seven synthetic pigments from wine and soft drinks using magnetic dispersive solid-phase extraction followed by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chen, Xiao-Hong; Zhao, Yong-Gang; Shen, Hao-Yu; Zhou, Li-Xin; Pan, Sheng-Dong; Jin, Mi-Cong

    2014-06-13

    A novel, simple and sensitive method based on the use of magnetic dispersive solid-phase extraction (M-dSPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) was developed to determine seven synthetic pigments (tartrazine, amaranth, carmine, sunset yellow, allura red, brilliant blue and erythrosine) in wines and soft drinks. An amino-functionalized low degrees of cross-linking magnetic polymer (NH2-LDC-MP) was synthesized via suspension polymerization, and characterized by transmission electron microscopy (TEM). The NH2-LDC-MP was used as the M-dSPE sorbent to remove the matrix from the solution, and the main factors affecting the extraction were investigated in detail. The obtained results demonstrated the higher extraction capacity of NH2-LDC-MP with recoveries between 84.0 and 116.2%. The limits of quantification (LOQs) for the seven synthetic pigments were between 1.51 and 5.0μg/L in wines and soft drinks. The developed M-dSPE UFLC-MS/MS method had been successfully applied to the real wines and soft drinks for food-safety risk monitoring in Zhejiang Province, China. The results showed that sunset yellow was in three out of thirty soft drink samples (2.95-42.6μg/L), and erythrosine in one out of fifteen dry red wine samples (3.22μg/L), respectively. It was confirmed that the NH2-LDC-MP was a kind of highly effective M-dSPE materials for the pigments analyses.

  18. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  19. Experimental design for the optimization and robustness testing of a liquid chromatography tandem mass spectrometry method for the trace analysis of the potentially genotoxic 1,3-diisopropylurea.

    Science.gov (United States)

    Székely, György; Henriques, Bruno; Gil, Marco; Alvarez, Carlos

    2014-09-01

    This paper discusses a design of experiments (DoE) assisted optimization and robustness testing of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development for the trace analysis of the potentially genotoxic 1,3-diisopropylurea (IPU) impurity in mometasone furoate glucocorticosteroid. Compared to the conventional trial-and-error method development, DoE is a cost-effective and systematic approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response are considered. The LC and MS factors were studied simultaneously: flow (F), gradient (G), injection volume (Vinj), cone voltage (E(con)), and collision energy (E(col)). The optimization was carried out with respect to four responses: separation of peaks (Sep), peak area (A(p)), length of the analysis (T), and the signal-to-noise ratio (S/N). An optimization central composite face (CCF) DoE was conducted leading to the early discovery of carry-over effect which was further investigated in order to establish the maximum injectable sample load. A second DoE was conducted in order to obtain the optimal LC-MS/MS method. As part of the validation of the obtained method, its robustness was determined by conducting a fractional factorial of resolution III DoE, wherein column temperature and quadrupole resolution were considered as additional factors. The method utilizes a common Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10-min runtime. The high sensitivity and low limit of quantification (LOQ) was achieved by (1) MRM mode (instead of single ion monitoring) and (2) avoiding the drawbacks of derivatization (incomplete reaction and time-consuming sample preparation). Quantitatively, the DoE method development strategy resulted in the robust trace analysis of IPU at 1.25 ng/mL absolute concentration

  20. Analysis of 19-nortestosterone residue in animal tissues by ion-trap gas chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Jin-qing JIANG; Lei ZHANG; Guang-ling LI; Hai-tang ZHANG; Xue-feng YANG; Jun-wei LIU; Ren-feng LI; Zi-liang WANG; Jian-hua WANG

    2011-01-01

    A rapid sample treatment procedure for the gas chromatography-tandem mass spectrometry (GC-MS) determination of 19-nortestosterone (19-NT) in animal tissues has been developed. In our optimized procedures, enzymatic hydrolysis with p-glucuronidase from Escherichia coli was performed in an acetate buffer (pH 5.2,0.2 mol/L). Next, the homogenate was mixed with methanol and heated at 60 掳C for 15 min, then placed in an ice-bath at -18 掳C for 2 h. After liquid-liquid extraction with n-hexane, the analytes were subjected to a normal-phase solid phase extraction (SPE) C18 cartridge for clean-up. The dried organic extracts were derivatized with heptafluorobutyric anhydride (HFBA), and then the products were injected into GC-MS. Using electron impact mass spectrometry (EI-MS) with positive chemical ionization (PCI), four diagnostic ions (mlz 666, 453, 318, and 306) were determined. A standard calibration curve over the concentration range of 1-20 ng/g was reached, with Y=467084X-68354 (R2=0.9997) for 19-NT, and the detection limit was 0.3 ng. When applied to spiked samples collected from bovine and ovine, the recoveries ranged from 63% to 101% with relative standard deviation (RSD) between 2.7% and 8.9%. The procedure is a highly efficient, sensitive, and more economical method which offers considerable potential to resolve cases of suspected nandrolone doping in husbandry animals.

  1. Multi-residue determination of pesticides in tropical fruits using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Botero-Coy, A M; Marín, J M; Ibáñez, M; Sancho, J V; Hernández, F

    2012-03-01

    Monitoring pesticide residues in tropical fruits is of great interest for many countries, e.g., from South America, that base an important part of their economy on the exportation of these products. In this work, a LC-MS/MS multi-residue method using a triple quadrupole analyzer has been developed for around 30 pesticides in seven Colombian tropical fruits of high commercial value for domestic and international markets (uchuva, tamarillo, granadilla, gulupa, maracuya, papaya, and pithaya). After sample extraction with acetonitrile, an aliquot of the extract was diluted with water and directly injected into the HPLC-MS/MS system (electrospray interface) without any cleanup step. The formation of sodium adducts-of poor fragmentation-was minimized using 0.1% formic acid in the mobile phase, which favored the formation of the protonated molecule. However, the addition of ammonium acetate made the formation of the ammonium adducts in some particular cases possible, avoiding the presence of the sodium adducts. The highest sensitivity was observed in positive electrospray ionization for the wide majority of pesticides, with a few exceptions for acidic compounds that gave better response in the negative mode (e.g., 2,4-D, fluazinan). Thus, simultaneous acquisition on the positive/negative mode was applied. Two MS/MS transitions were acquired for each compound to ensure a reliable quantification and identification of the compounds detected in samples, although for malathion a third transition was acquired due to the presence of interfering isobaric compounds in the sample extracts. A detailed study of matrix effects was made by a comparison of standards in solvent and in matrix. Both ionization suppression and ionization enhancement were observed depending on the analyte/matrix combination tested. Correction of matrix effects was made by the application of calibration in matrix. Three matrices were selected (uchuva, maracuya, gulupa) to perform matrix calibration in the

  2. [Simultaneous determination of four mercapturic acids in human urine using solid phase extraction and liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Hou, Hongwei; Xiong, Wei; Gao, Na; Song, Dongkui; Tang, Gangling; Hu, Qingyuan

    2011-01-01

    A method was developed for the simultaneous extraction and determination of four mercapturic acids (MAs), N-acetyl-S-(3,4-dihydroxybutyl)-L-cysteine (DHBMA), N-acetyl-S-(3-hydroxypropyl)-L-cysteine (3-HPMA), N-acetyl-S-(2-carboxyethyl)-L-cysteine ( CEMA) and S-phenylmercapturic acid (SPMA), in human urine using solid phase extraction and high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Frozen urine samples were thawed at room temperature, and centrifuged to remove any settled precipitate. The supernatant was then purified and concentrated by a C18 solid phase extraction column, and analyzed by HPLC-MS/MS in the multiple reaction monitoring (MRM) mode for the quantitative analysis. The ranges of recovery for DHBMA, 3-HPMA, CEMA and SPMA spiked in human urine matrix at three concentration levels were 105.6%-124.4%, 102.7%-106.5%, 103.2%-103.9% and 101.7%-104.3%, respectively, with the relative standard deviations of 2.6%-7.7%. The limits of detection (LOD, S/N > or = 3) were 0. 062, 0. 031, 0. 020 and 0. 003 microg/L for DHBMA, 3-HPMA, CEMA and SPMA, respectively. The method was successfully used to detect 4 MAs in 37 human urine samples from smokers and non-smokers. It was found that the contents of 3-HPMA, CEMA and SPMA in the urines from cigarette smokers were about three to six-fold more than those in the urines from the non-smokers.

  3. Determination of fluoroquinolones in aquaculture products by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    Science.gov (United States)

    Pearce, J N; Burns, B G; van de Riet, J M; Casey, M D; Potter, R A

    2009-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of fluoroquinolones-ciprofloxacin (CIPRO), danofloxacin (DANO), enrofloxacin (ENRO) and sarafloxacin (SARA)-in aquaculture products, specifically salmon, shrimp and tilapia. After initial sample extraction with an acidic acetonitrile solution, the extract was diluted with dichloromethane and centrifuged, then an aliquot was concentrated and applied to a C18 solid-phase extraction cartridge and concentrated for a second time. The resultant residue was dissolved in acetonitrile, diluted with water, and then further defatted with hexane. The fluoroquinolone residues were determined by UPLC with an HSS T3 C18 reverse-phase column using an ammonium hydroxide-formic acid buffer in an acetonitrile gradient with MS/MS detection using multiple reaction monitoring. Average recoveries for salmon tissue ranged from 73% for DANO to 95% for SARA, for shrimp from 71% for DANO to 109% for SARA, and from 62% for DANO to 111% for SARA in tilapia, fortified at the 1.0 ng g(-1) level. Standard curves were linear between 0.002 and 0.5 ng injected for all compounds. Detection limits of 0.2 ng g(-1) for CIPRO, DANO, ENRO, and SARA were easily obtainable. The operational errors, interferences, and recoveries for fortified samples demonstrate that this described method is suitable for routine use in a regulatory programme. The recommended method is simple, rapid, specific and reliable for the routine monitoring of fluoroquinolone residues in aquatic species such as salmon, tilapia and shrimp.

  4. Stable Isotope Dilution Analysis of Gibberellin Residues in Tomato Paste by Liquid Chromatography-Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    SUN Li; ZHAO Yan-sheng; NIE Xue-mei; LING Yun; CHU Xiao-gang; SHANG De-jun; DONG Ying

    2012-01-01

    An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3),gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA).The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression.After extraction from methanol,hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs,and the former gained better result.Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3,GA4 and GA7 were 42.6%-75.0% in external standard method(ESM) and 91.1%-103.8% in internal standard method(ISM) respectively.The validities of this method were investigated and good analytical performance for the three GAs was obtained,including low limits of method detection(2 ng/g for GA3 and GA4,0.3 ng/g for GA7),excellent linear dynamic ranges(5-500 ng/g for GA3 and GA4,1-100 ng/g for GAy) and good relative standard deviation ranges(4.8%-9.4% for the intra-day test and 3.5%-11.9% for the inter-day test).

  5. Identification and quantitation of amphetamines, cocaine, opiates, and phencyclidine in oral fluid by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Fritch, Dean; Blum, Kristen; Nonnemacher, Sheena; Haggerty, Brenda J; Sullivan, Matthew P; Cone, Edward J

    2009-01-01

    Analytical methods for measuring multiple licit and illicit drugs and metabolites in oral fluid require high sensitivity, specificity, and accuracy. With the limited volume available for testing, comprehensive methodology is needed for simultaneous measurement of multiple analytes in a single aliquot. This report describes the validation of a semi-automated method for the simultaneous extraction, identification, and quantitation of 21 analytes in a single oral fluid aliquot. The target compounds included are amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxy-amphetamine, 3,4-methylenedioxyethylamphetamine, pseudoephedrine, cocaine, benzoylecgonine, codeine, norcodeine, 6-acetylcodeine, morphine, 6-acetylmorphine, hydrocodone, norhydrocodone, dihydrocodeine, hydromorphone, oxycodone, noroxycodone, oxymorphone, and phencyclidine. Oral fluid specimens were collected with the Intercept device and extracted by solid-phase extraction (SPE). Drug recovery from the Intercept device averaged 84.3%, and SPE extraction efficiency averaged 91.2% for the 21 analytes. Drug analysis was performed by liquid chromatography-tandem mass spectrometry in the positive electrospray mode using ratios of qualifying product ions within +/-25% of calibration standards. Matrix ion suppression ranged from -57 to 8%. The limit of quantitation ranged from 0.4 to 5 ng/mL using 0.2 mL of diluted oral fluid sample. Application of the method was demonstrated by testing oral fluid specimens from drug abuse treatment patients. Thirty-nine patients tested positive for various combinations of licit and illicit drugs and metabolites. In conclusion, this validated method is suitable for simultaneous measurement of 21 licit and illicit drugs and metabolites in oral fluid.

  6. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    La’ulu, Sonia L.; Rasmussen, Kyle J.; Straseski, Joely A.

    2016-01-01

    Objective: Thyroid hormone concentrations fluctuate during growth and development. To accurately diagnose thyroid disease in pediatric patients, reference intervals (RIs) should be established with appropriate age groups from an adequate number of healthy subjects using the most exact methods possible. Obtaining statistically useful numbers of healthy patients is particularly challenging for pediatric populations. The objective of this study was to determine non-parametric RIs for free thyroxine (fT4) and free triiodothyronine (fT3) using equilibrium dialysis-high performance liquid chromatography-tandem mass spectrometry with over 2200 healthy children 6 months-17 years of age. Methods: Subjects were negative for both thyroglobulin and thyroid peroxidase autoantibodies and had normal thyrotropin concentrations. The study included 2213 children (1129 boys and 1084 girls), with at least 120 subjects (average of 125) from each year of life, except for the 6 month to 1 year age group (n=96). Results: Non-parametric RIs (95th percentile) for fT4 were: 18.0-34.7 pmol/L (boys and girls, 6 months-6 years) and 14.2-25.7 pmol/L (boys and girls, 7-17 years). RIs for fT3 were: 5.8-13.1 pmol/L (girls, 6 months-6 years); 5.7-11.8 pmol/L (boys, 6 months-6 years); 5.7-10.0 pmol/L (boys and girls, 7-12 years); 4.5-8.6 pmol/L (girls, 13-17 years); and 5.2-9.4 pmol/L (boys, 13-17 years). Conclusion: Numerous significant differences were observed between pediatric age groups and previously established adult ranges. This emphasizes the need for well-characterized RIs for thyroid hormones in the pediatric population. PMID:26758817

  7. Simultaneous determination of seven anticoagulant rodenticides in agricultural products by gel permeation chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi

    2016-11-01

    A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.

  8. Simultaneous determination of opiates, methadone, buprenorphine and metabolites in human urine by superficially porous liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lin, Huei-Ru; Chen, Chin-Lun; Huang, Chieh-Liang; Chen, Shao-Tsu; Lua, Ahai-Chuang

    2013-04-15

    For monitoring compliance of methadone or buprenorphine maintenance patient, a method for the simultaneous determination of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), buprenorphine, norbuprenorphine, opiates (morphine, codeine, 6-monoacetylmorphine) in urine by superficially porous liquid chromatography tandem mass spectrometry was developed and validated. After enzyme digestion and liquid-liquid extraction, reverse-phase separation was achieved in 5.2 min and quantification was performed by multiple reaction monitoring. Chromatographic separation was performed at 40 °C on a reversed phase Poroshell column with gradient elution. The mobile phase consisted of water and methanol, each containing 0.1% formic acid, at a flow rate of 0.32 mL/min. Intra-day and inter-day precision were less than 12.1% and accuracy was between -9.8% and 13.7%. Extraction efficiencies were more than 68%. Although ion suppression was detected, deuterated internal standards compensated for these effects. Carryover was minimal, less than 0.20%. All analytes were stable at room temperature for 16 h, 4 °C for 72 h, and after three freeze-thaw cycles. The assay also fulfilled compound identification criteria in accordance with the European Commission Decision 2002/657/EC. We analyzed 62 urine samples from patients received maintenance therapy and found that 54.8% of the patient samples tested were detected for morphine, codeine, or 6-monoacetylmorphine. This method provides a reliable and simultaneous quantification of opiates, maintenance drugs, and their metabolites in urine samples. It facilitates the routine monitoring in individuals prescribed the drug to ensure compliance and help therapeutic process.

  9. Determining indicator toxaphene congeners in soil using comprehensive two-dimensional gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhu, Shuai; Gao, Lirong; Zheng, Minghui; Liu, Huimin; Zhang, Bing; Liu, Lidan; Wang, Yiwen

    2014-01-01

    Toxaphene, which is a broad spectrum chlorinated pesticide, is a complex mixture of several hundred congeners, mainly polychlorinated bornanes. Quantifying toxaphene in environmental samples is difficult because of its complexity, and because each congener has a different response factor. Toxaphene chromatograms acquired using one-dimensional gas chromatography (1DGC) show that this technique cannot be used to separate all of the toxaphene congeners. We developed and validated a sensitive and quantitative method for determining three indicator toxaphene congeners in soil using an isotope dilution/comprehensive two-dimensional gas chromatography-tandem mass spectrometry (GC × GC-MS). The samples were extracted using accelerated solvent extraction, and then the extracts were purified using silica gel columns. (13)C₁₀-labeled Parlar 26 and 50 were used as internal standards and (13)C₁₀-labeled Parlar 62 was used as an injection standard. The sample extraction and purification treatments and the GC × GC-MS parameters were optimized. Subsequently the samples were determined by GC × GC-MS. The limits of detection for Parlar 26, 50, and 62 were 0.6 pg/g, 0.4 pg/g, and 1.0 pg/g (S/N=3), respectively, and the calibration curves had good linear correlations between 50 and 1000 μg/L (r(2)>0.99). Comprehensive two-dimensional GC gave substantial improvements over one-dimensional GC in the toxaphene analysis. We analyzed soil samples containing trace quantities of toxaphene to demonstrate that the developed method could be used to analyze toxaphene in environmental samples.

  10. Rapid and Sensitive Liquid Chromatography-Tandem Mass Spectrometry for Quantification of Glycyrrhctic Acid in Human Plasma

    Institute of Scientific and Technical Information of China (English)

    TIAN Li; GAO Xiao-li; CHEN Xiao-yan; ZHONG Da-fang; ZHANG Yi-fan; DAI Xiao-jian

    2011-01-01

    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry(LC-MS/MS) for the determination of glycyrrhetic acid in human plasma with ginsenoside Rh2 as internal standard was developed and validated. The plasma samples were prepared via liquid-liquid extraction with ethyl acetate. Chromatographic separation was accomplished on a Venusil MP-C1s(50 mm×2.1 mm, 5 μm i.d.) column at 25 ℃. The mobile phase consisted of acetonitrile/5 mmol·L-1 ammonium acetate(10:90, volume ratio) at a flow rate of 0.4 mL/min. Negative electrospray ionization was utilized as the ionization source. Glycyrrhetic acid and internal standard were determined via the mutiple reaction monitoring of precursor→production ion transitions at m/z 469→425, 409 and m/z 621→ 161,respectively. Each sample was chromatographed within 2.5 min. The lower limit of quantification was 0.50 ng/mL for 200 μL of plasma sample and the linear range was from 0.50 ng/mL to 800 ng/mL. The intra- and inter-day precisions were less than 8.76% in terms of relative standard deviation(RSD), and the accuracy was within a range of -3.25% -1.32% in terms of relative error(RE). The method was successfully applied to the pharmacokinetic studies of glycyrrhetic acid in healthy male Chinese volunteers after a single oral administration of 75 mg of glycyrrhizin.

  11. Sensitive method for detection of cocaine and associated analytes by liquid chromatography-tandem mass spectrometry in urine.

    Science.gov (United States)

    Langman, Loralie J; Bjergum, Matthew W; Williamson, Christopher L; Crow, Frank W

    2009-10-01

    Cocaine (COC) is a potent CNS stimulant that is metabolized to benzoylecgonine (BE) and further metabolized to minor metabolites such as m-hydroxybenzoylecgonine (m-HOBE). COC is also metabolized to norcocaine (NC). Cocaethylene (CE) is formed when cocaine and ethyl alcohol are used simultaneously. Anhydroecgonine methyl ester (AEME) is a unique marker following smoked cocaine, and anhydroecgonine ethyl ester (AEEE) is found in cocaine smokers who also use ethyl alcohol. We developed a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the detection and quantitation of COC, BE, NC, CE, m-HOBE, AEME, and AEEE in urine. Two hundred samples previously analyzed by gas chromatography (GC) coupled with MS were extracted using solid-phase extraction. Chromatographic separation was achieved using a gradient consisting of mobile phase A [20 mM ammonium formate (pH 2.7)] and mobile phase B (methanol/acetonitrile, 50:50), an XDB-C(8) (50 x 2.1 mm, 1.8 microm) column and a flow rate of 270 microL/min. Concentrations were calculated by comparing the peak-area with the internal standard and plotted against a standard curve. The assay displayed linearity from 1.0 to 100 ng/mL. Within- and between-run coefficients of variation were < 10% throughout the linear range. A method comparison between GC-MS and LC-MS-MS showed good correlation for COC (r(2) = 0.982) and BE (r(2) = 0.955). We report here on a sensitive method to identify clinically and forensically relevant cocaine and associated analytes at concentrations as low as 1.0 ng/mL.

  12. Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chen, Zhi-Feng; Ying, Guang-Guo; Lai, Hua-Jie; Chen, Feng; Su, Hao-Chang; Liu, You-Sheng; Peng, Fu-Qiang; Zhao, Jian-Liang

    2012-12-01

    A sensitive and robust method using solid-phase extraction and ultrasonic extraction for preconcentration followed by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) has been developed for determination of 19 biocides: eight azole fungicides (climbazole, clotrimazole, ketoconazole, miconazole, fluconazole, itraconazole, thiabendazole, and carbendazim), two insect repellents (N,N-diethyl-3-methylbenzamide (DEET), and icaridin (also known as picaridin)), three isothiazolinone antifouling agents (1,2-benzisothiazolinone (BIT), 2-n-octyl-4-isothiazolinone (OIT), and 4,5-dichloro-2-n-octyl-isothiazolinone (DCOIT)), four paraben preservatives (methylparaben, ethylparaben, propylparaben, and butylparaben), and two disinfectants (triclosan and triclocarban) in surface water, wastewater, sediment, sludge, and soil. Recovery of the target compounds from surface water, influent, effluent, sediment, sludge, and soil was mostly in the range 70-120%, with corresponding method quantification limits ranging from 0.01 to 0.31 ng L(-1), 0.07 to 7.48 ng L(-1), 0.01 to 3.90 ng L(-1), 0.01 to 0.45 ng g(-1), 0.01 to 6.37 ng g(-1), and 0.01 to 0.73 ng g(-1), respectively. Carbendazim, climbazole, clotrimazole, methylparaben, miconazole, triclocarban, and triclosan were detected at low ng L(-1) (or ng g(-1)) levels in surface water, sediment, and sludge-amended soil. Fifteen target compounds were found in influent samples, at concentrations ranging between 0.4 (thiabendazole) and 372 ng L(-1) (methylparaben). Fifteen target compounds were found in effluent samples, at concentrations ranging between 0.4 (thiabendazole) and 114 ng L(-1) (carbendazim). Ten target compounds were found in dewatered sludge samples, at concentrations ranging between 1.1 (DEET) and 887 ng g(-1) (triclocarban).

  13. Umbilical cord blood androgen levels in girls and boys assessed by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lundell, Anna-Carin; Ryberg, Henrik; Vandenput, Liesbeth; Rudin, Anna; Ohlsson, Claes; Tivesten, Åsa

    2017-07-01

    Androgen exposure of the fetus during gestation plays an important role in human physiology and pathophysiology, but assessment of androgens, in particular dihydrotestosterone (DHT), in human umbilical cord blood is technically challenging. The aim of this study was to assess umbilical cord androgen levels, including DHT, at birth by a highly sensitive assay, and study their association with sex of the infant, sex-hormone-binding globulin (SHBG) levels, and gestational age at delivery. Swedish infants (27 girls, 26 boys) were recruited at maternity care clinics in Southern Sweden. Umbilical cord blood levels of dehydroepiandrosterone (DHEA), androstenedione, testosterone and DHT at delivery were assessed by a gas chromatography-tandem mass spectrometry assay. Cord blood levels of DHT were 2.4-fold higher in boys (median 27.8pg/mL) than in girls (11.5pg/mL), while the sex difference was less pronounced for testosterone (1.3-fold higher in boys) and non-significant for DHEA and androstenedione. Gestational age at delivery associated inversely with DHT levels in boys and with DHEA levels in girls. There was a strong inverse correlation between SHBG and DHEA in both sexes, while there were no associations between SHBG and testosterone or DHT levels. In conclusion, using state of the art technology, we report that there is a pronounced sexual dimorphism in human umbilical cord blood DHT levels. The possibility to assess a complete androgen profile in human cord blood opens up for future increased understanding of the biological impact of the fetal androgen milieu. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Toxin Profile of Gymnodinium catenatum (Dinophyceae) from the Portuguese Coast, as Determined by Liquid Chromatography Tandem Mass Spectrometry

    Science.gov (United States)

    Costa, Pedro R.; Robertson, Alison; Quilliam, Michael A.

    2015-01-01

    The marine dinoflagellate Gymnodinium catenatum has been associated with paralytic shellfish poisoning (PSP) outbreaks in Portuguese waters for many years. PSP syndrome is caused by consumption of seafood contaminated with paralytic shellfish toxins (PSTs), a suite of potent neurotoxins. Gymnodinium catenatum was frequently reported along the Portuguese coast throughout the late 1980s and early 1990s, but was absent between 1995 and 2005. Since this time, G. catenatum blooms have been recurrent, causing contamination of fishery resources along the Atlantic coast of Portugal. The aim of this study was to evaluate the toxin profile of G. catenatum isolated from the Portuguese coast before and after the 10-year hiatus to determine changes and potential impacts for the region. Hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC-MS/MS) was utilized to determine the presence of any known and emerging PSTs in sample extracts. Several PST derivatives were identified, including the N-sulfocarbamoyl analogues (C1–4), gonyautoxin 5 (GTX5), gonyautoxin 6 (GTX6), and decarbamoyl derivatives, decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNeo) and decarbamoyl gonyautoxin 3 (dcGTX3). In addition, three known hydroxy benzoate derivatives, G. catenatum toxin 1 (GC1), GC2 and GC3, were confirmed in cultured and wild strains of G. catenatum. Moreover, two presumed N-hydroxylated analogues of GC2 and GC3, designated GC5 and GC6, are reported. This work contributes to our understanding of the toxigenicity of G. catenatum in the coastal waters of Portugal and provides valuable information on emerging PST classes that may be relevant for routine monitoring programs tasked with the prevention and control of marine toxins in fish and shellfish. PMID:25871287

  15. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    La'ulu, Sonia L; Rasmussen, Kyle J; Straseski, Joely A

    2016-03-05

    Thyroid hormone concentrations fluctuate during growth and development. To accurately diagnose thyroid disease in pediatric patients, reference intervals (RIs) should be established with appropriate age groups from an adequate number of healthy subjects using the most exact methods possible. Obtaining statistically useful numbers of healthy patients is particularly challenging for pediatric populations. The objective of this study was to determine non-parametric RIs for free thyroxine (fT4) and free triiodothyronine (fT3) using equilibrium dialysis-high performance liquid chromatography-tandem mass spectrometry with over 2200 healthy children 6 months-17 years of age. Subjects were negative for both thyroglobulin and thyroid peroxidase autoantibodies and had normal thyrotropin concentrations. The study included 2213 children (1129 boys and 1084 girls), with at least 120 subjects (average of 125) from each year of life, except for the 6 month to 1 year age group (n=96). Non-parametric RIs (95th percentile) for fT4 were: 18.0-34.7 pmol/L (boys and girls, 6 months-6 years) and 14.2-25.7 pmol/L (boys and girls, 7-17 years). RIs for fT3 were: 5.8-13.1 pmol/L (girls, 6 months-6 years); 5.7-11.8 pmol/L (boys, 6 months-6 years); 5.7-10.0 pmol/L (boys and girls, 7-12 years); 4.5-8.6 pmol/L (girls, 13-17 years); and 5.2-9.4 pmol/L (boys, 13-17 years). Numerous significant differences were observed between pediatric age groups and previously established adult ranges. This emphasizes the need for well-characterized RIs for thyroid hormones in the pediatric population.

  16. Determination of resveratrol and piceid in beer matrices by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chiva-Blanch, Gemma; Urpi-Sarda, Mireia; Rotchés-Ribalta, Maria; Zamora-Ros, Raul; Llorach, Rafael; Lamuela-Raventós, Rosa Maria; Estruch, Ramon; Andrés-Lacueva, Cristina

    2011-02-04

    Beer is one of the most commonly consumed undistilled alcoholic beverages in many countries. In recent studies, the stilbenes resveratrol and piceid have been found in some hop varieties which are used in the production of beer. Therefore, they could be transferred to beer. The aim of the present work was to validate a method to study the potential content of trans- and cis-resveratrol and piceid in 110 commercial beers from around the world. The resveratrol and piceid contents of 110 beers were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after a solid-phase extraction (SPE) using optimized and validated procedures for the beer matrix. The beer matrix effect was also studied. Stilbenes were found in quantifiable amounts in 92 beers, while concentrations below the limit of quantification (LOQ) were found in 18 beers. Resveratrol was found in the range of 1.34-77.0μg/L in 79% of the beers analyzed, and piceid was found in the range of 1.80-27.3μg/L in only 33% of them. The mean of total resveratrol in all the beers was 14.7±20.5μg/L. The content of resveratrol has been compared with other resveratrol containing foods. A serving of beer contains similar amounts of stilbenes as berries, less than chocolate and grape products but more than pistachios, peanuts or tomatoes. Overall, beer is one of the products with the lowest levels of total resveratrol (μg/L), and despite its high consumption it should not be considered as a representative source of resveratrol.

  17. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-01

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively.

  18. Effect of D-allose on prostate cancer cell lines: phospholipid profiling by nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jeong, Rae Ung; Lim, Sangsoo; Kim, Myoung Ok; Moon, Myeong Hee

    2011-08-01

    D-Allose, a rare, naturally occurring monosaccharide, is known to exert anti-proliferative effects on cancer cells. The effects of D-allose on the cellular membranes of hormone-refractory prostate cancer cell line (DU145), hormone-sensitive prostate cancer cell line (LNCaP), and normal prostate epithelial cells (PrEC) were studied at the molecular level by phospholipid (PL) profiling using a shotgun lipidomic method. The molecular structures of 85 PL species including 23 phosphatidylcholines, 12 phosphatidylethanolamines (PEs), 11 phosphatidylserines (PSs), 16 phosphatidylinositols, 9 phosphatidic acids (PAs), and 14 phosphatidylglycerols (PGs) were identified by data-dependent collision-induced dissociation of nanoflow liquid chromatography-tandem mass spectrometry, and the PL amounts were quantified. The addition of D-allose to prostate cancer cell lines during their growth phases had negligible or decreased effects on the relative regulation of PL species, but several new PS molecules (two for DU145 and three for LNCaP) emerged. In contrast, experiments on the PrEC cell line revealed that some high abundant species (14:0/14:0-PE, 16:2/16:0-PG, and 20:6/18:1-PA) showed significant increases in concentration. These findings support a mechanism for the anti-proliferative effect of D-allose on prostate cancer cell lines that involves the induction of programmed cell death since PS molecules are known to induce apoptosis. Principal component analysis was carried out to examine differences in PL distributions among the three cell lines promoted by D-allose.

  19. New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma

    Directory of Open Access Journals (Sweden)

    Tanveer A. Wani

    2015-09-01

    Full Text Available With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB, in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995 and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  20. Quantification of a male sea lamprey pheromone in tributaries of Laurentian Great Lakes by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Xi, X.; Johnson, N.S.; Brant, C.O.; Yun, S.-S.; Chambers, K.L.; Jones, A.D.; Li, W.

    2011-01-01

    We developed an assay for measuring 7α,12α,24-trihydroxy-5a-cholan-3-one-24-sulfate (3kPZS), a mating pheromone released by male sea lampreys (Petromyzon marinus), at low picomolar concentrations in natural waters to assess the presence of invasive populations. 3kPZS was extracted from streamwater at a rate of recovery up to 90% using a single cation-exchange and reversed-phase mixed-mode cartridge, along with [2H5]3kPZS as an internal standard, and quantified using ultrahigh performance liquid chromatography-tandem mass spectrometry. The limit of detection was below 0.1 ng L–1 (210 fM), which was the lowest concentration tested. Intra- and interday coefficients of variation were between 0.3–11.6% and 4.8–9.8%, respectively, at 1 ng 3kPZS L–1 and 5 ng 3kPZS L–1. This assay was validated by repeat measurements of water samples from a stream spiked with synthesized 3kPZS to reach 4.74 ng L–1 or 0.24 ng L–1. We further verified the utility of this assay to detect spawning populations of lampreys; in the seven tributaries to the Laurentian Great Lakes sampled, 3kPZS concentrations were found to range between 0.15 and 2.85 ng L–1 during the spawning season in known sea lamprey infested segments and were not detectable in uninfested segments. The 3kPZS assay may be useful for the integrated management of sea lamprey, an invasive species in the Great Lakes where pheromone-based control and assessment techniques are desired.

  1. Simple and rapid screening procedure for 143 new psychoactive substances by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Adamowicz, Piotr; Tokarczyk, Bogdan

    2016-07-01

    In recent years, many new psychoactive substances (NPS) from several drug classes have appeared on the drug market. These substances, also known as 'legal highs', belong to different chemical classes. Despite the increasing number of NPS, there are few comprehensive screening methods for their detection in biological specimens. In this context, the purpose of this study was to develop a fast and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening procedure for NPS in blood. The elaborated method allows the simultaneous screening of 143 compounds from different groups (number of compounds): cathinones (36), phenethylamines (26), tryptamines (18), piperazines (9), piperidines (2), synthetic cannabinoids (34), arylalkylamines (7), arylcyclohexylamines (3), aminoindanes (2), and other drugs (6). Blood samples (0.2 mL) were precipitated with acetonitrile (0.6 mL). The separation was achieved with gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 14 min. Detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The total number of transitions monitored in dynamic mode was 432. The whole procedure was rapid and simple. The limits of detection (LODs) estimated for 104 compounds were in the range 0.01-3.09 ng/mL. The extraction recoveries determined for 32 compounds were from 1.8 to 133%. The procedure was successfully applied to the analysis of forensic blood samples in routine casework. The developed method should have wide applicability for rapid screening of new drugs of abuse in forensic or clinical samples. The procedure can be easily expanded for more substances. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Detection of singly- and doubly-charged quaternary ammonium drugs in equine urine by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Ho, Emmie N M; Kwok, W H; Wong, April S Y; Wan, Terence S M

    2012-01-13

    Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous detection and confirmation of 38 singly- and doubly-charged QADs at sub-parts-per-billion (ppb) to low-ppb levels in equine urine after solid-phase extraction. Quaternary ammonium drugs were extracted from equine urine by solid-phase extraction (SPE) using an ISOLUTE(®) CBA SPE column and analysed by LC/MS/MS in the positive electrospray ionisation mode. Separation of the 38 QADs was achieved on a polar group embedded C18 LC column with a mixture of aqueous ammonium formate (pH 3.0, 10 mM) and acetonitrile as the mobile phase. Detection and confirmation of the 38 QADs at sub-ppb to low-ppb levels in equine urine could be achieved within 16 min using selected reaction monitoring (SRM). Matrix interference of the target transitions at the expected retention times was not observed. Other method validation data, including precision and recovery, were acceptable. The method was successfully applied to the analyses of drug-administration samples.

  3. Clinical and forensic examinations of glycaemic marker methylglyoxal by means of high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hess, Cornelius; Stratmann, Bernd; Quester, Wulf; Tschoepe, Diethelm; Madea, Burkhard; Musshoff, Frank

    2013-03-01

    The postmortem determination of hyperglycaemic coma is quite difficult because of the lack of morphological findings and the difficult interpretation of biochemical parameters. Methylglyoxal (MG) is a reactive oxoaldehyde, which is mainly derived from glycolysis. An electrospray ionisation liquid chromatography-tandem mass spectrometric procedure for the determination of methylglyoxal in human serum and postmortem blood was developed. It involves protein precipitation with perchloric acid and a derivatisation step with 2,3-diaminonaphthalene. The assay was validated according to international guidelines. Serum samples from diabetics obtained at a diabetes clinic and from non-diabetics were used to assess data about reference concentrations in human serum. The assay showed linearity within the physiological concentrations in serum (5-500 ng/ml). Intraday imprecision at three concentrations was 10.3, 9.2 and 8.3 %, and interday imprecision was 15.3, 14.2 and 9.4 %; the limit of detection was 1.3 ng/ml, and limit of quantification, 3.2 ng/ml. One hundred and eighteen clinical (100 diabetics, 18 non-diabetics) and 98 forensic samples (84 non-diabetics, 14 in a status of hyperglycaemic coma) were measured. During life, diabetics showed significantly (p < 0.001) higher serum concentrations of MG than non-diabetics. After death, concentrations of MG increased significantly (p < 0.001). However, there was no correlation between the sum formula of Traub in vitreous humour and MG femoral blood concentrations (R = 0.237). This indicates that MG concentrations in the deceased cannot distinguish deaths due to a hyperglycaemic coma from other causes of death.

  4. The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory

    NARCIS (Netherlands)

    van den Ouweland, Johannes M. W.; Kema, Ido P.

    2012-01-01

    Liquid chromatography coupled to mass spectrometry (LC-MS/MS) is increasingly used as a routine methodology in clinical laboratories for the analysis of low molecular weight molecules. The high specificity in combination with high sensitivity and multi-analyte potential makes it an attractive comple

  5. Determination of folic acid in human plasma using hydrophilic interaction chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Garbis, S.D.; Melse-Boonstra, A.; West, C.E.; Breemen, van R.B.

    2001-01-01

    Folic acid is an essential nutrient, and folate deficiency is associated with a variety of disorders including neural tube defects (during pregnancy) and heart disease. A fast, sensitive, and robust HPLC-tandem mass spectrometry (LC-MS-MS) method was developed for the quantification of free folic ac

  6. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  7. Determination of folic acid in human plasma using hydrophilic interaction chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Garbis, S.D.; Melse-Boonstra, A.; West, C.E.; Breemen, van R.B.

    2001-01-01

    Folic acid is an essential nutrient, and folate deficiency is associated with a variety of disorders including neural tube defects (during pregnancy) and heart disease. A fast, sensitive, and robust HPLC-tandem mass spectrometry (LC-MS-MS) method was developed for the quantification of free folic

  8. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Science.gov (United States)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  9. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    Science.gov (United States)

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

  10. Improving quantitative precision and throughput by reducing calibrator use in liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rule, Geoffrey S., E-mail: geoffrey.s.rule@aruplab.com [ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108 (United States); Rockwood, Alan L. [ARUP Institute for Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT 84108 (United States); Department of Pathology, University of Utah School of Medicine, 2100 Jones Medical Research Bldg., Salt Lake City, UT 84132 (United States)

    2016-05-05

    To improve efficiency in our mass spectrometry laboratories we have made efforts to reduce the number of calibration standards utilized for quantitation over time. We often analyze three or more batches of 96 samples per day, on a single instrument, for a number of assays. With a conventional calibration scheme at six concentration levels this amounts to more than 5000 calibration points per year. Modern LC-tandem mass spectrometric instrumentation is extremely rugged however, and isotopically labelled internal standards are widely available. This made us consider whether alternative calibration strategies could be utilized to reduce the number of calibration standards analyzed while still retaining high precision and accurate quantitation. Here we demonstrate how, by utilizing a single calibration point in each sample batch, and using the resulting response factor (RF) to update an existing, historical response factor (HRF), we are able to obtain improved precision over a conventional multipoint calibration approach, as judged by quality control samples. The laboratory component of this study was conducted with an existing LC tandem mass spectrometric method for three androgen analytes in our production laboratory. Using examples from both simulated and laboratory data we illustrate several aspects of our single point alternative calibration strategy and compare it with a conventional, multipoint calibration approach. We conclude that both the cost and burden of preparing multiple calibration standards with every batch of samples can be reduced while at the same time maintaining, or even improving, analytical quality. - Highlights: • Use of a weighted single point calibration approach improves quantitative precision. • A weighted response factor approach incorporates historical calibration information. • Several scenarios are discussed with regard to their influence on quantitation.

  11. Determination of Metformin in Human Plasma by Liquid Chromatography-tandem Mass Spectrometric Assay

    Institute of Scientific and Technical Information of China (English)

    WANG Jian; WANG Ying-wu; GU Jing-kai; WU Yi; WANG Yan

    2005-01-01

    @@ Introduction Metformin (1,1-dimethylbiguanide) (Fig. 1) is an oral anti-hyperglycemic agent used in the treatment of non-insulin-dependent diabetes mellitus (type Ⅱ). Owing to its weight-decreasing and serum lipid-normalizing effects, it is especially recommended for obese patients[1,2] Various analytical methods have been described for the measurement of metformin in biological fluids, including gas chromatography(GC)[3-5], capillary electrophoresis (CE)[6] and HPLC[7~16]with UV detection[7-12,17] HPLC-Mass spectrometry (LC/APCIMS/MS ) offers an attractive alternative to HPLC[18].

  12. Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Badenhorst, D; Sutherland, F C; de Jager, A D; Scanes, T; Hundt, H K; Swart, K J; Hundt, A F

    2000-05-26

    A sensitive method for the simultaneous determination of doxepin and its active metabolite desmethyldoxepin in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane-isoamyl alcohol, separated on a Phenomenex Luna C18 5 microm, 150x2.1 mm column with a mobile phase consisting of methanol-water-formic acid (600:400:0.5, v/v) at a flow-rate of 0.25 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer at unit resolution in multiple reaction monitoring mode monitoring the transition of the protonated molecular ions m/z 280.2, 266.2 and 250.1 to the product ions m/z 107.1, 107.1 and 191.0 for analyte, metabolite and internal standard (benzoctamine-HCl), respectively. TurbolonSpray ionisation was used for ion production. The mean recovery for doxepin and desmethyldoxepin was 90% and 75%, respectively, with a lower limit of quantification at 0.320 ng/ml and 0.178 ng/ml for the analyte and its metabolite, respectively, using 0.5 ml plasma for extraction. This is the first assay method described for the simultaneous determination of doxepin and desmethyldoxepin in plasma using LC-MS-MS. The method is sensitive enough to be used in drug bioavailability studies with doxepin.

  13. Determination of tolperisone in human plasma by liquid chromatography/tandem mass spectrometry for clinical application.

    Science.gov (United States)

    Choi, Chang-Ik; Park, Jung-In; Lee, Hye-In; Lee, Yun-Jeong; Jang, Choon-Gon; Bae, Jung-Woo; Lee, Seok-Yong

    2012-12-12

    We have developed and validated a simple, rapid, and sensitive liquid chromatography analytical method employing tandem mass spectrometry (LC-MS/MS) for the determination of tolperisone, a centrally acting muscle relaxant, in human plasma. After liquid-liquid extraction with methyl t-butyl ether, chromatographic separation of tolperisone was performed using a reversed-phase Luna C(18) column (2.0mm×50mm, 5μm particles) with a mobile phase of 10mM ammonium formate buffer (pH 3.5) - methanol (12:88, v/v) and quantified by tandem mass detection in ESI positive ion mode. The flow rate of the mobile phase was 250μL/min and the retention times of tolperisone and the internal standard (IS, dibucaine) were both 0.6min. The calibration curves were linear over a range of 0.5-300ng/mL (r>0.999). The lower limit of quantification, using 200μL human plasma, was 0.5ng/mL. The mean accuracy and precision for intra- and inter-day validation of tolperisone were within acceptable limits. The LC-MS/MS method reported here showed improved sensitivity for quantification of tolperisone in human plasma compared with previously described analytical methods. Lastly, the validated method was successfully applied to a pharmacokinetic study in humans.

  14. Simultaneous quantification of isoniazid, rifampicin, ethambutol and pyrazinamide by liquid chromatography/tandem mass spectrometry

    DEFF Research Database (Denmark)

    Prahl, Julie B; Lundqvist, Marika; Bahl, Justyna M C

    2016-01-01

    A remediable cause of poor treatment response in drug-susceptible tuberculosis (TB) patients may be low plasma levels of one or more of the first-line anti-TB drugs. The aim of this work was to develop an accurate and precise LC-MS/MS method for simultaneous quantification of all four first......-line anti-TB drugs in plasma suitable for therapeutic drug monitoring (TDM). To adjust for degradation and losses during sample preparation, isotopically labeled compounds were used as internal standards. Plasma samples spiked with internal standards were extracted using protein precipitation with methanol...... and acetonitrile. Simultaneous separation of all four drugs was accomplished with a Chromolith Reversed-Phase column and mobile phases consisting of water, methanol, ammonium acetate and formic acid with subsequent mass spectrometric quantification. The linear range of the calibration curve for isoniazid was 0...

  15. Multimycotoxin analysis in water and fish plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tolosa, J; Font, G; Mañes, J; Ferrer, E

    2016-02-01

    High performance liquid chromatography-mass spectrometry was used for the determination of 15 mycotoxins in water and fish plasma samples, including aflatoxins, fumonisins, ochratoxin A, sterigmatocistin, fusarenon-X and emerging Fusarium mycotoxins. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a sample treatment for the simultaneous extraction of mycotoxins. Results showed differences in recovery assays when different extraction solvents were employed. Ethyl acetate showed better recoveries for the major part of mycotoxins analyzed, except for aflatoxins B2, G1 and G2, which showed better recoveries when employing chloroform as extractant solvent. Fumonisins and beauvericin exhibited low recoveries in both water and plasma. This method was validated according to guidelines established by European Commission and has shown to be suitable to be applied in dietary and/or toxicokinetic studies in fish where is necessary to check mycotoxin contents in rearing water and fish plasma.

  16. Analysis of daphnane orthoesters in poisonous Australian pimelea species by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chow, Sharon; Fletcher, Mary T; McKenzie, Ross A

    2010-06-23

    Cattle grazing in arid rangelands of Australia suffer periodic extensive and serious poisoning by the plant species Pimelea trichostachya, P. simplex, and P. elongata. Pimelea poisoning (also known as St. George disease and Marree disease) has been attributed to the presence of the diterpenoid orthoester simplexin in these species. However, literature relating to previous studies is complicated by taxonomic revisions, and the presence of simplexin has not previously been verified in all currently recognized taxa capable of inducing pimelea poisoning syndrome, with no previous chemical studies of P. trichostachya (as currently classified) or P. simplex subsp. continua. We report here the isolation of simplexin from P. trichostachya and the development of a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method to measure simplexin concentrations in pimelea plant material. Simplexin was quantified by positive-ion atmospheric pressure chemical ionization (APCI) LC-MS/MS with selected reaction monitoring (SRM) of the m/z 533.3 > 253.3 transition. LC-MS/MS analysis of the four poisonous taxa P. trichostachya, P. elongata, P. simplex subsp. continua, and P. simplex subsp. simplex showed similar profiles with simplexin as the major diterpenoid ester component in all four taxa accompanied by varying amounts of related orthoesters. Similar analyses of P. decora, P. haematostachya, and P. microcephala also demonstrated the presence of simplexin in these species but at far lower concentrations, consistent with the limited reports of stock poisoning associated with these species. The less common, shrubby species P. penicillaris contained simplexin at up to 55 mg/kg dry weight and would be expected to cause poisoning if animals consumed sufficient plant material.

  17. Targeted High Performance Liquid Chromatography Tandem Mass Spectrometry-based Metabolomics differentiates metabolic syndrome from obesity.

    Science.gov (United States)

    Zhong, Fanyi; Xu, Mengyang; Bruno, Richard S; Ballard, Kevin D; Zhu, Jiangjiang

    2017-04-01

    Both obesity and the metabolic syndrome are risk factors for type 2 diabetes and cardiovascular disease. Identification of novel biomarkers are needed to distinguish metabolic syndrome from equally obese individuals in order to direct them to early interventions that reduce their risk of developing further health problems. We utilized mass spectrometry-based targeted metabolic profiling of 221 metabolites to evaluate the associations between metabolite profiles and established metabolic syndrome criteria (i.e. elevated waist circumference, hypertension, elevated fasting glucose, elevated triglycerides, and low high-density lipoprotein cholesterol) in plasma samples from obese men ( n = 29; BMI = 35.5 ± 5.2 kg/m(2)) and women ( n = 40; 34.9 ± 6.7 kg/m(2)), of which 26 met the criteria for metabolic syndrome (17 men and 9 women). Compared to obese individuals without metabolic syndrome, univariate statistical analysis and partial least squares discriminant analysis showed that a specific group of metabolites from multiple metabolic pathways (i.e. purine metabolism, valine, leucine and isoleucine degradation, and tryptophan metabolism) were associated with the presence of metabolic syndrome. Receiver operating characteristic curves generated based on the PLS-DA models showed excellent areas under the curve (0.85 and 0.96, for metabolites only model and enhanced metabolites model, respectively), high specificities (0.86 and 0.93), and good sensitivities (0.71 and 0.91). Moreover, principal component analysis revealed that metabolic profiles can be used to further differentiate metabolic syndrome with 3 versus 4-5 metabolic syndrome criteria. Collectively, these findings support targeted metabolomics approaches to distinguish metabolic syndrome from obesity alone, and to stratify metabolic syndrome status based on the number of criteria met. Impact statement We utilized mass spectrometry-based targeted metabolic profiling of 221 metabolites to

  18. Pharmacokinetics of HZ08 in rats by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Weng, Jing-yan; Song, Min; Hang, Tai-jun; Huang, Wen-long; Du, Yun

    2007-09-01

    A selective and sensitive liquid chromatographic method coupled with ion spray tandem mass spectrometry detection (LC-MS/MS) was developed for the determination and pharmacokinetic study of N-cyano-1-[(3,4-dimethoxyphenyl)methyl]-3,4-dihydro-6,7-dimethoxy-N'-octyl-2(1H)-isoquinoline-carboximidamide (HZ08, a candidate reversing agent for multidrug resistance of cancer) liposome injection in rat plasma. The analyte was extracted from plasma using liquid-liquid extraction by methyl tert-butyl ether with drotaverine as internal standard. The chromatographic separation was performed on a Kromasil-C18 column (150 mm x 4.6 mm, i.d., 5 microm) with gradient elution. The tandem mass detection was made with electrospray ionization in positive ion selected reaction monitoring mode with argon collision-induced dissociation. The ion transitions were m/z 523.1 to 342.1 for HZ08 at 27eV and m/z 398.1 to 326.1 at 35eV for the internal standard, respectively. The determination was validated to be accurate and precise for the analysis in the concentration range of 5-10,000 ng/ml for HZ08 with the lower limit of detection (LOD) being 1 ng/ml, when 0.1 ml of rat plasma sample was processed. The main pharmacokinetic parameters found for HZ08 after intravenous (i.v.) administration of its liposome injection at doses of 2, 4 and 8 mg/kg were as follows: C(max) (4511+/-681), (5553+/-1600) and (6444+/-950) ng/ml, T(max) (0.033+/-0), (0.056+/-0.048) and (0.033+/-0) h, t(1/2) (1.75+/-0.19), (1.63+/-0.12) and (1.56+/-0.18) h, AUC(0-6) (899+/-112), (1238+/-190) and (1707+/-307) h ng/ml, AUC(0-infinity) (917+/-110), (1256+/-189) and (1723+/-306) h ng/ml, MRT (1.14+/-0.21), (1.01+/-0.13) and (1.16+/-0.17) h, CL (2.90+/-0.15), (3.01+/-0.74) and (4.11+/-0.59)l/h/kg, respectively. The plasma concentration-time profiles of HZ08 were best fitted with two-compartment models. Linear pharmacokinetics was found for HZ08 in rats after intravenous administration of the liposome injection.

  19. Pharmacokinetic studies of novel berberine derivatives with ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Wenchao; Shen, Qin; Liang, Hui; Hua, Changlong; Liu, Yuhui; Li, Fengzhi; Li, Qingyong

    2016-09-15

    An ultra-performance liquid chromatography with tandem mass spectrometric detection method was developed for the detection of berberine and its derivatives (A4, B4) in rat plasma and other organs. This validated method was successfully applied to our pharmacokinetic study of BBR derivatives in rats. At the same dose of administration, the Cmax of B4 was about eight times higher than BBR, and its half-life was approximately two times longer than BBR, according to the bigger areas under plasma concentration curves. Inversely, the pharmacokinetic parameter levels of A4 were all inferior to BBR, suggesting a tight structure-activity relationship of these compounds. Small dose of parenteral administration was used for the study of absolute oral bioavailability of A4, B4, and BBR, and the results calculated were 0.12%, 3.4% and 0.7%, respectively. The accumulations of B4 among all organs were intestine>liver>heart>kidney>lung>spleen>plasma, proving a deeply targeting property of B4, which met our experimental assumption. Together, the experimental results proved that compared with BBR and A4, the derivative B4 had higher absolute oral bioavailability and the ability of deeply targeting so that can be likely used in some organ-targeted diseases.

  20. Simultaneous determination of acidic pesticides in vegetables and fruits by liquid chromatography--tandem mass spectrometry.

    Science.gov (United States)

    Shida, Shizuka S; Nemoto, Satoru; Matsuda, Rieko

    2015-01-01

    A sensitive and efficient method has been developed for the simultaneous determination of 73 multi-class acidic pesticides, such as phenoxy acid and sulfonylurea herbicides, in vegetables and fruits. The sample preparation procedure was carefully optimized for the efficient removal of co-extracted matrix components. The method involves extraction of acidic pesticides with acetonitrile containing hydrochloric acid, removal of water from crude extract by salting out, and sequential cleanup by octadecylsilyl silica gel and silica gel columns. For samples containing high amounts of pigments, such as spinach, additional cleanup using a graphitized carbon column was performed prior to liquid chromatography-mass spectrometry (LC-MS/MS) analysis. Recovery tests were performed for five times for each sample of cabbage, spinach, potato, eggplant, orange, and apple fortified at 0.01 mg kg-1. Out of the 73 tested pesticides, 70 for cabbage, 67 for spinach, 69 for potato, 67 for eggplant, 64 for orange, and 70 for apple were within the range of 70-120%, with relative standard deviations below 25%. Nitenpyram and pyrasulfotole showed low recoveries for all the samples tested, probably due to low recoveries from silica gel column. The developed method effectively removed co-extracted matrix components and was highly selective, with no interfering peaks found in the chromatograms of blank samples. The overall results indicate that the developed method is suitable for the quantitative analysis of acidic pesticide residues in vegetables and fruits.

  1. Control of levamisole residues in milk using a validated liquid chromatography-tandem mass spectrometry method

    Directory of Open Access Journals (Sweden)

    Nina Bilandžić

    2016-03-01

    Full Text Available Concentrations of the anthelmintic agent levamisole were measured in a total of 85 raw cow milk samples collected during 2014 from dairy farms across Croatia. The liquid chromatographytandem mass spectrometry (LC-MS/MS method used for levamisole quantification was validated according to the criteria set by Commission Decision 2002/657/EC. The following validation parameters were determined: limit of decision (CCα 0.55 μg kg-1, detection of capability (CCβ 0.59 μg kg-1, limit of detection (LOD 0.06 μg kg-1, limit of quantification (LOQ 0.22 μg kg-1, precision and accuracy (expressed as recovery 97.3-100 %, intra-laboratory reproducibility (RSD 4.2-5.6 %. Levamisole levels for 45 of the total of 85 samples were below the LOD value (0.06 µg kg-1. In the remaining 40 milk samples, levamisole was measured in the range from 0.061 to 0.142 µg kg-1 and the mean value was 0.092 µg kg-1. Accordingly, all concentrations analysed were below the LOQ value (0.22 µg kg-1 and limit of decision (CCα of the method used.

  2. Global Analysis of the Membrane Subproteome of Pseudomonas aeruginosa using Liquid Chromatography-Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blonder, Josip; Goshe, Michael B.; Xiao, Wenzhong; Camp, David G.; Wingerd, Mark A.; Davis, Ronald W.; Smith, Richard D.

    2004-05-30

    Pseudomonas aeruginosa is one of the most significant opportunistic bacterial pathogens in humans causing infections and premature death in patients with cystic fibrosis, AIDS, severe burns, organ transplants or cancer. Liquid chromatography coupled online with tandem mass spectrometry (LC-MS/MS) was used for the large-scale proteomic analysis of the P. aeruginosa membrane subproteome. Concomitantly, an affinity labeling technique, using iodoacetyl-PEO biotin to tag cysteinyl-containing proteins, permitted the enrichment and detection of lower abundance membrane proteins. The application of these approaches resulted in the identification of 786 proteins. A total of 333 proteins (42%) had a minimum of one transmembrane domain (TMD; ranging from 1 to 14) and 195 proteins were classified as hydrophobic based on their positive GRAVY values (ranging from 0.01 to 1.32). Key integral inner and outer membrane proteins involved in adaptation and antibiotic resistance were conclusively identified, including the detection of 53% of all predicted opr-type porins (outer integral membrane proteins) and all the components of the mexA-mexB-oprM transmembrane protein complex. This work represents the most comprehensive qualitative proteomic analysis of the membrane subproteome of P. aeruginosa and for prokaryotes in general to date.

  3. [Determination of seven toxaphene congeners in ginseng and milkvetch root by gas chromatography tandem mass spectrometry].

    Science.gov (United States)

    Tian, Shaoqiong; Mao, Xiuhong; Miao, Shui; Jia, Zhengwei; Wang, Ke; Ji, Shen

    2012-01-01

    A novel method for the determination of representative toxaphene congeners in traditional Chinese herbal medicines was developed. Ginseng and Milkvetch Root were selected as the samples and seven toxaphene congeners were selected as the monitoring objects. The samples were extracted by accelerated solvent extraction with cyclohexane-acetone (9:1, v/v), then cleaned-up by Florisil solid phase extraction with hexane as the eluent and the residues were detected by gas chromatography-electron ionization tandem mass spectrometry (GC-EI-MS/MS) in multiple reaction monitoring (MRM) mode. The performance was demonstrated by the analysis of Ginseng and Milkvetch Root samples spiked with toxaphene congeners at three concentration levels of 0.005, 0.01 and 0.1 mg/kg. The recoveries ranged from 72.4% to 105% with the relative standard deviations (RSDs) of 0.96%-10.4%. The limits of detection (LODs) were 0.2-1.7 microg/kg. This method is sensitive and efficient in the aspect of extraction, and can be applied to monitor the residue of toxaphene congeners in Ginseng and Milkvetch Root.

  4. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  5. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  6. Selective extraction and determination of neonicotinoid insecticides in wine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Cabo, T; Casado, J; Rodríguez, I; Ramil, M; Cela, R

    2016-08-19

    A simplified, high throughput procedure for the determination of five neonicotinoid insecticides in red and white wines, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS), is presented. The effects of different experimental parameters (extraction sorbent, solvent elution and clean-up conditions) in the efficiency and the selectivity of the sample preparation process were assessed through calculation of the extraction yields and the matrix effects (MEs). Wines (10mL) were concentrated using OASIS HLB cartridges, on-line connected to Florisil clean-up cartridges, with acetonitrile serving as the elution solvent. The extract (5mLvol) was concentrated to 1mL and injected in the LC-ESI-MS/MS system. The optimized procedure provided quantitative extraction yields at the same time that the efficiency of ESI ionization remained unchanged between standards and sample extracts. Overall recoveries, calculated against authentic standards in ACN, varied between 77 and 119% and the attained limits of quantification remained below 0.2ngmL(-1). Analysis of commercial wines revealed imidacloprid residues in more than 50% of processed samples, with a maximum level of 14ngmL(-1). Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Analysis of gibberellins as free acids by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Urbanová, Terezie; Tarkowská, Danuše; Novák, Ondřej; Hedden, Peter; Strnad, Miroslav

    2013-08-15

    A robust, reliable and high-throughput method for extraction and purification of gibberellins (GAs), a group of tetracyclic diterpenoid carboxylic acids that include endogenous growth hormones, from plant material was developed. The procedure consists of two solid-phase extraction steps (Oasis(®) MCX-HLB and Oasis(®) MAX) and gives selective enrichment and efficient clean-up of these compounds from complex plant extracts. The method was tested with plant extracts of Brassica napus and Arabidopsis thaliana, from which total recovery of internal standards of about 72% was achieved. A rapid baseline chromatographic separation of 20 non-derivatised GAs by ultra performance liquid chromatography is also presented where a reversed-phase chromatographic column Acquity CSH(®) and a mobile phase consisting of methanol and aqueous 10mM-ammonium formate is used. This method enables sensitive and precise quantitation of GAs by MS/MS in multiple-reaction monitoring mode (MRM) by a standard isotope dilution method. Optimal conditions, including final flow rate, desolvation temperature, desolvation gas flow, capillary and cone voltage for effective ionisation in the electrospray ion source were found. All studied GAs were determined as free acids giving dominant quasi-molecular ions of [M-H](-) with limits of detection ranging between 0.08 and 10 fmol and linear ranges over four orders of magnitude. Taking advantage of highly effective chromatographic separation of 20 GAs and very sensitive mass spectrometric detection, the presented bioanalytical method serves as a useful tool for plant biologists studying the physiological roles of these hormones in plant development.

  8. Simultaneous quantitation of amphetamines and opiates in human hair by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Liu, Hsiu-Chuan; Liu, Ray H; Lin, Dong-Liang

    2015-04-01

    In this study, an incubation, solid-phase extraction (SPE) and LC-MS-MS procedure was developed, validated and used for simultaneous analysis of amphetamine (AP), methamphetamine (MA), morphine (MOR), codeine (COD), 6-acetylmorphine (6-AM) and 6-acetylcodeine (6-AC) in hair. Hair samples were initially cut into sections, washed with dichloromethane, then sonicated in a methanol-trifluoroacetic acid mixture. The resulting solutions were processed with a SPE procedure before undergoing LC-MS-MS analysis. Mass spectrometric analysis was performed in positive-ion, multiple reactions monitoring (MRM) mode, using appropriate collision energy for each selected precursor ion. The overall protocol, when applied to the analysis of hair (50 mg) samples fortified with 100-10,000 pg/mg of the analytes, was found to achieve 55.5-74.6% recovery of the six analytes with the following analytical parameters: (i) intra- and interday precision/accuracy data for the six analytes in the 1.6-7.6%/-6.0-12.8% and 1.3-6.6%/-6.9-9.3% ranges, respectively; (ii) r(2) > 0.998 for all six analytes and (iii) LOD 2 pg/mg for AP and MA, and 8 pg/mg for MOR, COD, 6-AM and 6-AC; LOQ 10 pg/mg for all six analytes. This method was then utilized to (i) analyze hair samples collected from 86 self-reported drug users and (ii) evaluate the deposition pattern of drugs in head hairs from four female MA and heroin users in a rehabilitation facility. This relatively simple protocol was found superior over the GC-MS methods we have previously developed and utilized in our laboratory for the analysis of these six analytes.

  9. Determination of triapine, a ribonucleotide reductase inhibitor, in human plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Feng, Ye; Kunos, Charles A; Xu, Yan

    2015-09-01

    Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation-mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC-MS/MS method for the determination of triapine in human plasma. In this method, 2-[(3-fluoro-2-pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mM, pH 8.50; v/v); column eluate was monitored by positive turbo-ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple-reaction-monitoring mode. The method developed had a linear calibration range of 0.250-50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS-normalized recovery and the IS-normalized matrix factor of triapine were 101-104% and 0.89-1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC-MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial.

  10. Validation of keratan sulfate level in mucopolysaccharidosis type IVA by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tomatsu, Shunji; Montaño, Adriana M; Oguma, Toshihiro; Dung, Vu Chi; Oikawa, Hirotaka; de Carvalho, Talita Giacomet; Gutiérrez, María L; Yamaguchi, Seiji; Suzuki, Yasuyuki; Fukushi, Masaru; Kida, Kazuhiro; Kubota, Mitsuru; Barrera, Luis; Orii, Tadao

    2010-12-01

    Mucopolysaccharidosis type IVA (MPS IVA, Morquio A disease), a progressive lysosomal storage disease, causes skeletal chondrodysplasia through excessive storage of keratan sulfate (KS). KS is synthesized mainly in cartilage and released to the circulation. The excess storage of KS disrupts cartilage, consequently releasing more KS into circulation, which is a critical biomarker for MPS IVA. Thus, assessment of KS level provides a potential screening strategy and determines clinical course and efficacy of therapies. We have recently developed a tandem mass spectrometry liquid chromatography [LC/MS/MS] method to assay KS levels in blood. Forty-nine blood specimens from patients with MPS IVA [severe (n = 33), attenuated (n = 11) and undefined (n = 5)] were analyzed for comparison of blood KS concentration with that of healthy subjects and for correlation with clinical severity. Plasma samples were digested by keratanase II to obtain disaccharides of KS. Digested samples were assayed by LC/MS/MS. We found that blood KS levels (0.4-26 µg/ml) in MPS IVA patients were significantly higher than those in age-matched controls (0.67-4.6 µg/ml; P IVA peaked between 2 years and 5 years of age (mean 11.4 µg/ml). Blood KS levels in severe MPS IVA (mean 7.3 µg/ml) were higher than in the attenuated form (mean 2.1 µg/ml) (P = 0.012). We also found elevated blood KS levels in other types of MPS. These findings indicate that the new KS assay for blood is suitable for early diagnosis and longitudinal assessment of disease severity in MPS IVA.

  11. Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Caffeine in Caffeine-Laced Pants and in Urine and Skin of a Pants User

    OpenAIRE

    Manuela Pellegrini; Daniela De Orsi; Carmine Guarino; Maria Concetta Rotolo; Rita di Giovannandrea; Roberta Pacifici; Simona Pichini

    2014-01-01

    A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the measurement of caffeine in caffeine-laced pants and in urine and skin of a pants user. The substance and its internal standard (N-ethylnorcotinine) were separated by reversed phase chromatography with 5 mM ammonium formate pH 3.0 and 0.3% formic acid in acetonitrile mobile phase (83:17 v/v) by isocratic elution and detected by tandem mass spectrometry operated in multiple reacti...

  12. Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Raro, M.; Portolés, T.; Pitarch, E.; Sancho, J.V.; Hernández, F. [Research Institute for Pesticides and Water, University Jaume I, E-12071 Castellón (Spain); Garrostas, L. [Bioanalysis Research Group, IMIM, Hospital del Mar Medical Research Institute, Doctor Aiguader 88, 08003 Barcelona (Spain); Marcos, J.; Ventura, R.; Segura, J. [Bioanalysis Research Group, IMIM, Hospital del Mar Medical Research Institute, Doctor Aiguader 88, 08003 Barcelona (Spain); Department of Experimental and Health Sciencies, Universitat Pompeu Fabra, Doctor Aiguader 88, 08003 Barcelona (Spain); Pozo, O.J., E-mail: opozo@imim.es [Bioanalysis Research Group, IMIM, Hospital del Mar Medical Research Institute, Doctor Aiguader 88, 08003 Barcelona (Spain)

    2016-02-04

    The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid–liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H]{sup +} or [M + H-2TMSOH]{sup +} ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL{sup −1}. Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected. - Highlights: • APCI source has been evaluated for the screening of 16 exogenous AAS in urine. • Suitable

  13. Development of a liquid chromatography/tandem mass spectrometry method for the quantitation of acetylcholine and related neurotransmitters in brain microdialysis samples.

    Science.gov (United States)

    Zhang, Mei-Yi; Hughes, Zoë A; Kerns, Edward H; Lin, Qian; Beyer, Chad E

    2007-06-28

    Monitoring concentrations of acetylcholine (ACh) in specific brain regions is important in understanding disease pathology, as well as in designing and evaluating novel disease-modifying treatments where cholinergic dysfunction is a hallmark feature. We have developed a sensitive and quantitative liquid chromatography/tandem mass spectrometry method to analyze the extracellular concentrations of ACh, choline (Ch) and (3-carboxylpropyl)-trimethylammonium (iso-ACh) in brain microdialysis samples of freely moving animals. One immediate advantage of this new method is the ability to monitor ACh in its free form without having to use a cholinesterase inhibitor in the perfusate. The separation of ACh, Ch, iso-ACh and related endogenous compounds was carried out based on cation exchange chromatography with a volatile elution buffer consisting of ammonium formate, ammonium acetate and acetonitrile. An unknown interference of ACh, which was observed in brain microdialysates from many studies, was well separated from ACh to ensure the accuracy of the measurement. Optimization of electrospray ionization conditions for these quaternary ammonium compounds achieved the limits of detection (S/N=3) of 0.2 fmol for ACh, 2 fmol for Ch and 0.6 fmol for iso-ACh using a benchtop tandem quadrupole mass spectrometer with moderate sensitivity. The limit of quantitation (S/N=10) was 1 fmol for ACh, 3 fmol for iso-ACh and 10 fmol for Ch. This method was selective, precise (iso-ACh and 15-3000 nM for Ch. To demonstrate that the developed method can be applied to monitoring changes in ACh concentrations in vivo, reference agents that have previously been shown to influence ACh levels were studied in rat dorsal hippocampus. This includes the 5-HT6 receptor antagonist, SB-271046, and the cholinesterase inhibitor, donepezil. Moreover, levels of ACh were demonstrated to be sensitive to infusion of tetrodotoxin (TTX) suggesting that the ACh being measured in vivo was of neuronal origin

  14. Simultaneous determination of triazines and their main transformation products in surface and urban wastewater by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Benvenuto, Federica; Marín, José M; Sancho, Juan V; Canobbio, Sergio; Mezzanotte, Valeria; Hernández, Félix

    2010-08-01

    This work describes the optimization, validation and application of an ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the quantification and confirmation of 11 compounds (atrazine, simazine, terbuthylazine, terbumeton, terbutryn and their main transformation products) in surface and wastewater samples. Several of these analytes are included in the list of priority substances in the framework on European Water Policy. The application of this method to water samples reveals that the most relevant transformation products (TPs) should be incorporated into current analytical methods to obtain a more realistic knowledge of water quality regarding pesticide contamination. TPs are generally more polar and mobile than parents and can be transported to the aquatic environment more easily than their precursors. This can explain their concentrations found in water, which in many cases are much higher than intact triazines. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyser was used. Working in selected reaction monitoring mode, up to three simultaneous transitions per compound were acquired, allowing a reliable quantification and confirmation at nanogram per litre levels. The method developed includes a pre-concentration step based on solid-phase extraction (OASIS HLB cartridges). Satisfactory recoveries (70-120%) and relative standard deviations (<20%) were obtained for all compounds in different water sample types spiked at two concentrations (0.025 and 0.1 microg/L in surface water; 0.25 and 1.0 microg/L in effluent wastewater; 0.5 and 2.0 microg/L in influent wastewater). The optimized method was found to have excellent sensitivity with instrumental detection limits as low as 0.03 pg. In addition, the influence of the matrix constituents on the ionization efficiency and the extraction recovery was studied in different types of Italian and Spanish surface and urban wastewater. Signal

  15. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine.

    Science.gov (United States)

    Fraselle, S; De Cremer, K; Coucke, W; Glorieux, G; Vanmassenhove, J; Schepers, E; Neirynck, N; Van Overmeire, I; Van Loco, J; Van Biesen, W; Vanholder, R

    2015-04-15

    Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The

  16. Plasma pharmacokinetics and bioavailability of verticillin A following different routes of administration in mice using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Wang, Jiang; Zhu, Xiaohua; Kolli, Shamala; Wang, Hongyan; Pearce, Cedric J; Oberlies, Nicholas H; Phelps, Mitch A

    2017-05-30

    Verticillin A is a natural product isolated from fungal cultures and has displayed potent antibiotic, antiviral, nematocidal, and anticancer properties in vitro. While in vivo studies have been limited due to sparse supply, the in vivo efficacy data that does exist demonstrates potent anti-tumor activity in murine cancer models. The current study aims to investigate the pharmacokinetics and bioavailability of verticillin A in mice to provide guidance for further efficacy assessment in mouse models. A sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of verticillin A in mouse plasma. Sample preparation was accomplished through protein precipitation, and chromatographic separation was achieved on an Agilent Zorbax Extend C18 column with a security guard cartridge C8 using a binary gradient with mobile phase A (water/0.1% formic acid) and B (ACN/0.1% formic acid) at a flow rate of 400μl/min. Elution of verticillin A and internal standard, hesperetin, occurred at 4.87 and 2.06min, respectively. The total chromatographic run time was 8min, and the assay was linear in the concentration range of 1-1000nM. The within- and between day precisions and accuracy were in the range of 2.58-8.71 and 90-105%, respectively. The assay was applied to determine plasma drug concentration in a mouse pharmacokinetic study. It was found that intraperitoneal dosing of 3mg/kg resulted in high systemic exposure and achieved Cmax of 110nM with plasma concentrations sustained above 10nM for the 24-h duration of the study. Intravenous and oral dosing achieved observed Cmax of 73nM and 9nM, respectively. Oral dosing resulted in an approximate 9% bioavailability. Comparing with previously published in vitro studies that demonstrated verticillin A is active in the 20nM to 130nM range, the pharmacokinetic data demonstrate similar levels are achieved in mouse plasma via intravenous or intraperitoneal dosing routes

  17. Determination of perfluorinated compounds in mollusks by matrix solid-phase dispersion and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Villaverde-de-Sáa, Eugenia; Quintana, José Benito; Rodil, Rosario; Ferrero-Refojos, Raúl; Rubí, Elisa; Cela, Rafael

    2012-01-01

    Perfluorinated compounds (PFCs) have been used for over 40 years in different commercial and industrial applications mainly as surfactants and surface protectors and have become an important class of marine emerging pollutants. This study presents the development and validation of a new analytical method to determine the simultaneous presence of eight PFCs in different kinds of mollusks using matrix solid-phase dispersion (MSPD) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simplicity of the analytical procedure, low volume of solvent and quantity of sample required, low global price, and integration of extraction and clean-up into a single step, are the most important advantages of the developed methodology. Solvent, solid support (dispersing agent), clean-up sorbent, and their amounts were optimized by means of an experimental design. In the final method, 0.5 g of sample are dispersed with 0.2 g of diatomaceous earth and transferred into a polypropylene syringe containing 4 g of silica as clean-up sorbent. Then, analytes are eluted with 20 mL of acetonitrile. The extract is finally concentrated to a final volume of 0.5 mL in methanol, avoiding extract dryness in order to prevent evaporation losses and injected in the LC-MS/MS. The combination of this MSPD protocol with LC-MS/MS afforded detection limits from 0.05 to 0.3 ng g(-1). Also, a good linearity was established for the eight PFCs in the range from limit of quantification (LOQ) to 500 ng mL(-1) with R(2) > 0.9917. The recovery of the method was studied with three types of spiked mollusk and was in the 64-126% range. Moreover, a mussel sample was spiked and aged for more than 1 month and analyzed by the developed method and a reference method, ion-pair extraction, for comparison, producing both methods statistically equal concentration values. The method was finally applied to the determination of PFCs in different kinds of mollusks revealing concentrations up to 8.3 ng g(-1) for

  18. Simultaneous detection of five one-carbon metabolites in plasma using stable isotope dilution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Adaikalakoteswari, Antonysunil; Webster, Craig; Goljan, Ilona; Saravanan, Ponnusamy

    2016-02-15

    Disturbance in one-carbon (1-C) cycle occurs due to nutritional deficiencies (vitamin B12/folate) or specific genetic polymorphisms. This leads to altered levels of key 1-C metabolites such as SAM (s-adenosyl methionine), SAH (s-adenosyl homocysteine), methionine, homocysteine and MMA (methyl malonic acid). These 1-C metabolites are determinants of cellular methylation potential and epigenetic modifications of DNA which impairs metabolic pathways in several pathological diseases and developmental programming. Though methods were able to measure these analytes only independently, none of the methods detect simultaneously. Therefore we developed a method to measure these five 1-C metabolites in a single run using liquid chromatography tandem mass spectrometry (LC-MS/MS). We used stable isotopes dilution LC-MS/MS to measure the 1-C metabolites in human plasma. Blood samples were collected from pregnant women (n=30) at early gestation in the ongoing, multicentre, prospective PRiDE study. Linearity exhibited across the calibration range for all the analytes with the limit of detection (LOD) of 1.005nmol/l for SAM, 0.081nmol/l for SAH, 0.002μmol/l for methionine, 0.046μmol/l for homocysteine and 3.920nmol/l for MMA. The average recovery for SAM was 108%, SAH-110%, methionine-97%, homocysteine-91% and MMA-102%. The inter-assay CV for SAM was 7.3, SAH-5.6%, methionine-3.5%, homocysteine-7.0% and MMA-4.0%. The intra-assay CV for SAM was 8.7%, SAH-4.7%, methionine-5.4%, homocysteine-8.1% and MMA-6.1%. Pregnant women at early gestation with low B12 levels had significantly higher homocysteine, MMA, lower levels of methionine, SAM and SAM:SAH ratio and higher triglycerides. We developed a simple and rapid method to simultaneously quantify 1-C metabolites such as SAM, SAH, methionine, homocysteine and MMA in plasma by stable isotope dilution LC-MS/MS which would be useful to elucidate the epigenetic mechanisms related in the gene-nutrient interactions.

  19. Quantification of vitamin B6 vitamers in human cerebrospinal fluid by ultra performance liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ham, M. van der, E-mail: M.vanderHam-3@umcutrecht.nl [Department of Metabolic Diseases and Netherlands Metabolomics Center, University Medical Center (UMC) Utrecht, Huispost KC02.069.1, Lundlaan 6, 3584 EA Utrecht (Netherlands); Albersen, M., E-mail: M.Albersen@umcutrecht.nl [Department of Metabolic Diseases and Netherlands Metabolomics Center, University Medical Center (UMC) Utrecht, Huispost KC02.069.1, Lundlaan 6, 3584 EA Utrecht (Netherlands); Koning, T.J. de, E-mail: T.deKoning@umcutrecht.nl [Department of Pediatric Metabolic Diseases, Wilhelmina Children' s Hospital, University Medical Center (UMC) Utrecht, Huispost KC03.063.0, Lundlaan 6, 3584 EA Utrecht (Netherlands); Visser, G., E-mail: G.Visser-4@umcutrecht.nl [Department of Pediatric Metabolic Diseases, Wilhelmina Children' s Hospital, University Medical Center (UMC) Utrecht, Huispost KC03.063.0, Lundlaan 6, 3584 EA Utrecht (Netherlands); Middendorp, A., E-mail: Alfred_Middendorp@waters.com [Waters Chromatography B.V., Florijnstraat 19, Postbus 379, 4870 AJ Etten-Leur (Netherlands); Bosma, M., E-mail: M.Bosma@umcutrecht.nl [Department of Metabolic Diseases and Netherlands Metabolomics Center, University Medical Center (UMC) Utrecht, Huispost KC02.069.1, Lundlaan 6, 3584 EA Utrecht (Netherlands); Verhoeven-Duif, N.M., E-mail: N.Verhoeven@umcutrecht.nl [Department of Metabolic Diseases and Netherlands Metabolomics Center, University Medical Center (UMC) Utrecht, Huispost KC02.069.1, Lundlaan 6, 3584 EA Utrecht (Netherlands); Sain-van der Velden, M.G.M. de, E-mail: M.G.deSain@umcutrecht.nl [Department of Metabolic Diseases and Netherlands Metabolomics Center, University Medical Center (UMC) Utrecht, Huispost KC02.069.1, Lundlaan 6, 3584 EA Utrecht (Netherlands)

    2012-01-27

    Highlights: Black-Right-Pointing-Pointer We present a sensitive UPLC-MS/MS method for quantification of B6 vitamers in human CSF. Black-Right-Pointing-Pointer Our method is very accurate since stable isotope labeled internal standards are used. Black-Right-Pointing-Pointer We present data on light sensitivity, temperature dependence and rostrocaudal gradient. Black-Right-Pointing-Pointer With PN supplementation, concentrations of PL, PM, PN and PA in CSF are increased. Black-Right-Pointing-Pointer Our fully validated method is suitable for implementation in a diagnostic setting. - Abstract: Since vitamin B6 is essential for normal functioning of the central nervous system, there is growing need for sensitive analysis of B6 vitamers in cerebrospinal fluid (CSF). This manuscript describes the development and validation of a rapid, sensitive and accurate method for quantification of the vitamin B6 vitamers pyridoxal (PL), pyridoxamine (PM), pyridoxine (PN), pyridoxic acid (PA), pyridoxal 5 Prime -phosphate (PLP), pyridoxamine 5 Prime -phosphate (PMP) and pyridoxine 5 Prime -phosphate (PNP) in human CSF. The method is based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with a simple sample preparation procedure of protein precipitation using 50 g L{sup -1} trichloroacetic acid containing stable isotope labeled internal standards: PL-D{sub 3} for PL and PM, PN-{sup 13}C{sub 4} for PN, PA-D{sub 2} for PA and PLP-D{sub 3} for the phosphorylated vitamers. B6 vitamers were separated (Acquity HSS-T3 UPLC column) with a buffer containing acetic acid, heptafluorobutyric acid and acetonitrile. Positive electrospray ionization was used to monitor transitions m/z 168.1 {yields} 150.1 (PL), 169.1 {yields} 134.1 (PM), 170.1 {yields} 134.1 (PN), 184.1 {yields} 148.1 (PA), 248.1 {yields} 150.1 (PLP), 249.1 {yields} 232.1 (PMP) and 250.1 {yields} 134.1 (PNP). The method was validated at three concentration levels for each B6 vitamer in CSF

  20. Rapid analysis of pharmaceuticals and personal care products in fish plasma micro-aliquots using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chen, Fangfang; Gong, Zhiyuan; Kelly, Barry C

    2015-02-27

    A sensitive analytical method based on liquid-liquid extraction (LLE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed for rapid analysis of 11 pharmaceuticals and personal care products (PPCPs) in fish plasma micro-aliquots (∼20μL). Target PPCPs included, bisphenol A, carbamazepine, diclofenac, fluoxetine, gemfibrozil, ibuprofen, naproxen, risperidone, sertraline, simvastatin and triclosan. A relatively quicker and cheaper LLE procedure exhibited comparable analyte recoveries with solid-phase extraction. Rapid separation and analysis of target compounds in fish plasma extracts was achieved by employing a high efficiency C-18 HPLC column (Agilent Poroshell 120 SB-C18, 2.1mm×50mm, 2.7μm) and fast polarity switching, enabling effective monitoring of positive and negative ions in a single 9min run. With the exception of bisphenol A, which exhibited relatively high background contamination, method detection limits of individual PPCPs ranged between 0.15 and 0.69pg/μL, while method quantification limits were between 0.05 and 2.3pg/μL. Mean matrix effect (ME) values ranged between 65 and 156% for the various target analytes. Isotope dilution quantification using isotopically labelled internal surrogates was utilized to correct for signal suppression or enhancement and analyte losses during sample preparation. The method was evaluated by analysis of 20μL plasma micro-aliquots collected from zebrafish (Danio rerio) from a laboratory bioaccumulation study, which included control group fish (no exposure), as well as fish exposed to environmentally relevant concentrations of PPCPs. Using the developed LC-MS/MS based method, concentrations of the studied PPCPs were consistently detected in the low pg/μL (ppb) range. The method may be useful for investigations requiring fast, reliable concentration measurements of PPCPs in fish plasma. In particular, the method may be applicable for in situ contaminant biomonitoring, as well as

  1. Rapid determination of benzodiazepines, zolpidem and their metabolites in urine using direct injection liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jeong, Yu-Dong; Kim, Min Kyung; Suh, Sung Ill; In, Moon Kyo; Kim, Jin Young; Paeng, Ki-Jung

    2015-12-01

    Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 μL) mixed with 80 μL of the IS solution were centrifuged. An aliquot (5 μL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 μm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully

  2. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of ε-Acetamidocaproic Acid in Rat Plasma

    OpenAIRE

    Kim, Tae Hyun; Choi1, Yong Seok; Choi, Young Hee; Kim, Yoon Gyoon

    2013-01-01

    A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ε-acetamidocaproic acid (AACA), the primary metabolite of zinc acexamate (ZAC), in rat plasma by using normetanephrine as an internal standard. Sample preparation involved protein precipitation using methanol. Separation was achieved on a Gemini-NX C18 column (150 mm × 2.0 mm, i.d., 3 μm particle size) using a mixture of 0.1% formic acid-water : acetonitril...

  3. Quantitation of metabolites of the nerve agents sarin, soman, cyclohexylsarin, VX, and Russian VX in human urine using isotope-dilution gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Barr, John R; Driskell, W J; Aston, Linda S; Martinez, Rodolfo A

    2004-01-01

    Organophosphorus nerve agents are among the most toxic organic compounds known and continue to be a threat for both military and terrorist use. We have developed an isotope-dilution gas chromatography-tandem mass spectrometric (GC-MS-MS) method for quantitating the urinary metabolites of the organophosphorus nerve agents sarin (GB), soman (GD), VX, Russian VX (RVX), and cyclohexylsarin (GF). Urine samples were acidified, extracted into ether-acetonitrile, derivatized by methylation with diazomethane, and analyzed by GC-MS-MS. The limits of detection were less than 1 micro g/L for all analytes.

  4. Targeted Multiresidue Analysis of Veterinary Drugs in Milk-Based Powders Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    Science.gov (United States)

    Wittenberg, James B; Simon, Kelli A; Wong, Jon W

    2017-08-30

    An analytical method was developed and validated for the determination of 40 veterinary drugs in various milk-based powders. The method involves acetonitrile/water extraction, solid-phase filtration for lipid removal in fat-containing matrices, and analysis using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The limits of quantitation (LOQ) ranged from 0.02 to 82 ng/g. Acceptable recoveries (70-120%, RSD powder. Similar results were obtained for whole milk powder, milk protein concentrate, whey protein concentrate, and whey protein isolate. This new method will allow for better monitoring of a wide range of veterinary drugs in milk-based powders.

  5. Determination of pazopanib (GW-786034) in mouse plasma and brain tissue by liquid chromatography-tandem mass spectrometry (LC/MS-MS)

    OpenAIRE

    Minocha, Mukul; Khurana, Varun; Mitra, Ashim K.

    2012-01-01

    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LC/MS-MS) method has been developed and validated for the quantitative determination of pazopanib in mouse plasma and brain tissue homogenate. Single liquid-liquid extraction step with ethyl acetate was employed for analysis of pazopanib and the internal standard (IS); vandetanib. HPLC separation was performed on an XTerra® MS C18 column 50 × 4.6mm, 5.0 μm. The mobile phase consisted of 70% acetonitrile and 30% wat...

  6. Sensitive analysis of blonanserin, a novel antipsychotic agent, in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi

    2010-01-01

    A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  7. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation.

    Science.gov (United States)

    Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian

    2016-09-05

    4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats.

  8. Rapid simultaneous analysis of 17 haloacetic acids and related halogenated water contaminants by high-performance ion chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Xue, Runmiao; Donovan, Ariel; Shi, Honglan; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd

    2016-09-01

    Haloacetic acids (HAAs), which include chloroacetic acids, bromoacetic acids, and emerging iodoacetic acids, are toxic water disinfection byproducts. General screening methodology is lacking for simultaneously monitoring chloro-, bromo-, and iodoacetic acids. In this study, a rapid and sensitive high-performance ion chromatography-tandem mass spectrometry method for simultaneous determination of chloro-, bromo-, and iodo- acetic acids and related halogenated contaminants including bromate, bromide, iodate, and iodide was developed to directly analyze water samples after filtration, eliminating the need for preconcentration, and chemical derivatization. The resulting method was validated in both untreated and treated water matrices including tap water, bottled water, swimming pool water, and both source water and drinking water from a drinking water treatment facility to demonstrate application potential. Satisfactory accuracies and precisions were obtained for all types of tested samples. The detection limits of this newly developed method were lower or comparable with similar techniques without the need for extensive sample treatment requirement and it includes all HAAs and other halogenated compounds. This provides a powerful methodology to water facilities for routine water quality monitoring and related water research, especially for the emerging iodoacetic acids. Graphical abstract High performance ion chromatography-tandem mass spectrometry method for detection of haloacetic acids in water.

  9. Determination of stanozolol and 3′-hydroxystanozolol in rat hair, urine and serum using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Deshmukh Nawed IK

    2012-12-01

    Full Text Available Abstract Background Anabolic androgenic steroids, such as stanozolol, are typically misused by athletes during preparation for competition. Out-of-competition testing presents a unique challenge in the current anti-doping detection system owing to logistic reasons. Analysing hair for the presence of a prohibited drug offers a feasible solution for covering the wider window in out-of-competition testing. To assist in vivo studies aiming to establish a relationship between drug levels detected in hair, urine and blood, sensitive methods for the determination of stanozolol and its major metabolite 3′-hydroxystanozolol were developed in pigmented hair, urine and serum, using brown Norway rats as a model system and liquid chromatography tandem mass spectrometry (LC-MS/MS. Results For method development, spiked drug free rat hair, blood and urine samples were used. The newly developed method was then applied to hair, urine and serum samples from five brown Norway rats after treatment (intraperitoneal with stanozolol for six consecutive days at 5.0 mg/kg/day. The assay for each matrix was linear within the quantification range with determination coefficient (r2 values above 0.995. The respective assay was capable of detecting 0.125 pg/mg stanozolol and 0.25 pg/mg 3′-hydroxystanozolol with 50 mg hair; 0.063 ng/mL stanozolol and 0.125 ng/mL 3′-hydroxystanozolol with 100 μL of urine or serum. The accuracy, precision and extraction recoveries of the assays were satisfactory for the detection of both compounds in all three matrices. The average concentrations of stanozolol and 3′-hydroxystanozolol, were as follows: hair = 70.18 ± 22.32 pg/mg and 13.01 ± 3.43 pg/mg; urine = 4.34 ± 6.54 ng/mL and 9.39 ± 7.42 ng/mL; serum = 7.75 ± 3.58 ng/mL and 7.16 ± 1.97 ng/mL, respectively. Conclusions The developed methods are sensitive, specific and reproducible for the determination of stanozolol

  10. Liquid chromatography-mass spectrometric and liquid chromatography-tandem mass spectrometric determination of hallucinogenic indoles psilocin and psilocybin in "magic mushroom" samples.

    Science.gov (United States)

    Kamata, Tooru; Nishikawa, Mayumi; Katagi, Munehiro; Tsuchihashi, Hitoshi

    2005-03-01

    Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.

  11. Characterization of lemon (Citrus limon) polar extract by liquid chromatography-tandem mass spectrometry in high resolution mode.

    Science.gov (United States)

    Ledesma-Escobar, C A; Priego-Capote, F; Luque de Castro, M D

    2015-11-01

    Eighty four metabolites (32 flavonoids, 15 amino acids, nine carboxylic acids, six coumarins, six sugars, five phenolic acids and 11 unclassified compounds) have been tentatively identified in a polar extract from lemon, without reference standards, based on their liquid chromatography-quadrupole-time-of-flight MS/MS spectra and the comparison with databases. Despite information in databases for some families of plant compounds is poor, tentative identification based on MS/MS information (mass of the precursor ion and their fragments, together with neutral mass loss) was possible with the help of known fragmentation patterns for the given families of compounds. Both positive and negative ionization modes and at least two collision energies were always applied to obtain as much information as possible from each molecular entity, thus helping for identification. As the tentatively identified metabolites are the same regardless of the organism they belong, their fragmentation patterns are useful for identification with independence of the sample nature.

  12. Multi-component quantitation of loratadine, pseudoephedrine and paracetamol in plasma and pharmaceutical formulations with liquid chromatography-tandem mass spectrometry utilizing a monolithic column

    Directory of Open Access Journals (Sweden)

    Kamran Abro

    2012-01-01

    Full Text Available The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE, paracetamol (PAR and loratadine (LOR in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition of methanol-0.1% formic acid at a flow rate of 1.0 mL min-1. Mass spectral transitions were recorded in SRM mode. System validation was evaluated for precision, specificity and linearity. Limit of detection for pseudoephedrine, paracetamol, and loratadine were determined to be 3.14, 1.86 and 1.44 ng mL-1, respectively, allowing easy determination in plasma with % recovery of 93.12 to 101.56%.

  13. Simultaneous determination of 14-thienyl methylene matrine and matrine in rat plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study.

    Science.gov (United States)

    Jiang, Minjie; Wang, Lisheng; Jiang, Weizhe; Huang, Shulin

    2015-01-01

    A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS) has been developed and validated for the simultaneous determination of 14-thienyl methylene matrine (TMM) and matrine (MT) in rat plasma in the present study. The analytes were separated on a C18 column (1.9 μm, 2.1 mm × 100 mm) with a security guard C18 column (5 μm, 2.1 mm × 10 mm) and a triple-quadrupole mass spectrometry equipped with an electrospray ionization (ESI) source was applied for detection. With pseudoephedrine hydrochloride as internal standard, sample pretreatment involved in a one-step protein precipitation with isopropanol:ethyl acetate (v/v, 20:80). The method was linear over the concentration ranges of 5-1000 ng/ml for TMM and 10-2000 ng/ml for MT. The intra-day and inter-day relative standard deviations (RSD) were less than 15% and the relative errors (RE) were all within 15%. The proposed method enables unambiguous identification and quantification of TMM and MT in vivo. This was the first report on determination of the TMM and MT in rat plasma after oral administration of TMM. The results provided a meaningful basis for evaluating the clinical applications of the medicine.

  14. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China); Shen Jianzhong, E-mail: sjz@cau.edu.cn [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China)

    2009-10-05

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 {mu}g kg{sup -1}, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  15. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  16. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  17. Detection of Sulfur-Fumigated Paeoniae Alba Radix in Complex Preparations by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Song-Lin Li

    2012-07-01

    Full Text Available Detection of sulfur-fumigated Paeoniae Alba Radix (PAR in different complex preparations is challenging due to the relatively lower content of PAR and interference from more complicated components in complex preparations with different multiple constituent herbs. In this study, a high performance liquid chromatography- triple-quadrupole tandem mass spectrometry method was developed for detecting sulfur-fumigated PAR in different complex preparations. Paeoniflorin, the major component of PAR, and paeoniflorin sulfonate, the characteristic artifact transformed from paeoniflorin during sulfur-fumigation of PAR, were used as chemical markers. Multiple reaction monitoring (MRM scan was employed to maximize sensitivity and selectivity. Through optimizing full mass scan and daughter ion scan conditions, two mass transitions were selected and employed respectively for unequivocal identification of paeoniflorin and paeoniflorin sulfonate. The detection limits for paeoniflorin and paeoniflorin sulfonate using MRM were much lower than those detected with UV 270 nm. Paeoniflorin and paeoniflorin sulfonate could be simultaneously detected in different commercial PAR-containing complex preparations without interference of other components using the established method, indicating that the newly established method was selective and sensitive enough for screening sulfur-fumigated PAR in commercial complex preparations.

  18. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    Science.gov (United States)

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (supercritical fluid based chromatography coupled with tandem mass spectrometry.

  19. Construction of an Ultrahigh Pressure Liquid Chromatography-Tandem Mass Spectral Library of Plant Natural Products and Comparative Spectral Analyses.

    Science.gov (United States)

    Lei, Zhentian; Jing, Li; Qiu, Feng; Zhang, Hua; Huhman, David; Zhou, Zhiqin; Sumner, Lloyd W

    2015-07-21

    A plant natural product tandem mass spectral library has been constructed using authentic standards and purified compounds. Currently, the library contains 1734 tandem mass spectra for 289 compounds, with the majority (76%) of the compounds being plant phenolics such as flavonoids, isoflavonoids, and phenylpropanoids. Tandem mass spectra and chromatographic retention data were acquired on a triple quadrupole mass spectrometer coupled to an ultrahigh pressure liquid chromatograph using six different collision energies (CEs) (10-60 eV). Comparative analyses of the tandem mass spectral data revealed that the loss of ring substituents preceded the C-ring opening during the fragmentation of flavonoids and isoflavonoids. At lower CE (i.e., 10 and 20 eV), the flavonoids and isoflavonoid central ring structures typically remained intact, and fragmentation was characterized by the loss of the substituents (i.e., methyl and glycosyl groups). At higher CE, the flavonoid and isoflavonoid core ring systems underwent C-ring cleavage and/or rearrangement depending on the structure, particularly hydroxylation patterns. In-source electrochemical oxidation was observed for phenolics that had ortho-diphenol moieties (i.e., vicinal hydroxyl groups on the aromatic rings). The ortho-diphenols were oxidized to ortho-quinones, yielding an intensive and, in most cases, a base ion peak corresponding to a [(M - 2H) - H](-) ion in their mass spectra. The library also contains reverse-phase retention times, allowing for the construction, validation, and testing of an artificial neural network retention prediction of other flavonoids and isoflavonoids not contained within the library. The library is freely available for nonprofit, academic use and it can be downloaded at http://www.noble.org/apps/Scientific/WebDownloadManager/DownloadArea.aspx.

  20. Performance characterization of a quantitative liquid chromatography-tandem mass spectrometric method for 12 macrolide and lincosamide antibiotics in salmon, shrimp and tilapia.

    Science.gov (United States)

    Dickson, Leslie C

    2014-09-15

    This paper describes an extension and performance characterization of a quantitative confirmatory multi-residue liquid chromatography-tandem mass spectrometric method for residues of macrolide and lincosamide antibiotics, originally validated for application to bovine kidney tissues, to tissues of salmon, shrimp and tilapia. The 12 analytes include clindamycin, erythromycin A, gamithromycin, josamycin, lincomycin, neospiramycin 1, oleandomycin, pirlimycin, spiramycin 1, tildipirosin, tilmicosin and tylosin A. The limit of detection was 0.5 μg/kg. Within-laboratory precision evaluated over the analytical range of 5.0-50.0 μg/kg ranged from 4 to 17%. The accuracy of the method ranged from 80 to 112%. Recoveries ranged from 47 to 99% with all but one recovery above 60%. This is the first report of a quantitative confirmatory method for gamithromycin, pirlimycin and tildipirosin in fish and shrimp.

  1. Multi-residue and multi-class method for the determination of antibiotics in bovine muscle by ultra-high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Freitas, Andreia; Barbosa, Jorge; Ramos, Fernando

    2014-09-01

    A multi-residue quantitative screening method covering 41 antibiotics from 7 different families, by ultra-high-performance-liquid-chromatography tandem mass spectrometry (UHPLC-MS/MS), is described. Sulfonamides, trimethoprim, tetracyclines, macrolides, quinolones, penicillins and chloramphenicol are simultaneously detected after a simple sample preparation of bovine muscle optimized to achieve the best recovery for all compounds. A simple sample treatment was developed consisting in an extraction with a mixture of acetonitrile and ethylenediaminetetraacetic acid (EDTA), followed by a defatting step with n-hexane. The methodology was validated, in accordance with Decision 2002/657/EC by evaluating the required parameters: decision limit (CCα), detection capability (CCβ), specificity, repeatability and reproducibility. Precision in terms of relative standard deviation was under 20% for all compounds and the recoveries between 91% and 119%. CCα and CCβ were determined according the maximum residue limit (MRL) or the minimum required performance limit (MRPL), when required.

  2. Development and validation of a multiclass method for the quantification of veterinary drug residues in honey and royal jelly by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jin, Yue; Zhang, Jinzhen; Zhao, Wen; Zhang, Wenwen; Wang, Lin; Zhou, Jinhui; Li, Yi

    2017-04-15

    The aim of this study was to develop an analytical method for the analysis of a wide range of veterinary drugs in honey and royal jelly. A modified sample preparation procedure based on the quick, easy, cheap, effective, rugged and safe (QuEChERS) method was developed, followed by liquid chromatography tandem mass spectrometry determination. Use of the single sample preparation method for analysis of 42 veterinary drugs becomes more valuable because honey and royal jelly belong to completely different complex matrices. Another main advantage of the proposed method is its ability to identify and quantify 42 veterinary drugs with higher sensitivity than reference methods of China. This work has shown that the reported method was demonstrated to be convenient and reliable for the quick monitoring of veterinary drugs in honey and royal jelly samples.

  3. [Analysis of proteins in the extracts of Physalis alkekengi L. var. franchetii (Mast.) Makino using nanoflow reversed-phase liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yu, Haiyang; Yan, Jiaze; Guo, Ming; Jin, Yan

    2013-04-01

    The protein was extracted from Physalis alkekengi L. var. franchetii (Mast.) Makino fruit by using water extraction and acid precipitation methods, and it consisted of 188 mg/g of protein on dry basis of the extract. Among 18 amino acids, eight essential amino acids for human account for 31% were found in this extract. Based on shotgun proteomics method, the protein extracted from Physalis fruit was analysed by nanoflow reversed-phase liquid chromatography-tandem mass spectrometry (nano-RPLC-MS/MS) system. Combined with database searches and bioinformatics analysis, the protein species and six molecular functions were identified, including with catalytic activity, antioxidant activity, enzyme regular activity, nutrient reservoir activity, transporter activity and binding activity. And three antioxidant activity-related proteins were identified. These results may lay the foundation for further study of the functional properties of the proteins in Physalis fruit.

  4. Refined methodology for the determination of neonicotinoid pesticides and their metabolites in honey bees and bee products by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Kamel, Alaa

    2010-05-26

    An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.

  5. Phenolic Compounds of Pinus brutia Ten.: Chemical Investigation and Quantitative Analysis Using an Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry with Electrospray Ionization Source

    Directory of Open Access Journals (Sweden)

    İbrahim Kıvrak

    2013-08-01

    Full Text Available In this study, phenolic content of Pinus brutia ’s bark was examined using an ultra-performance liquid chromatography tandem mass spectrometry with electrospray ionization source (UPLC-ESI-MS/MS working in multiple reaction monitoring mode. U ltrasonic extraction method with 50% ethanol solution was used for the extraction of bark. The bark of Pinus brutia consisted of 15 compounds: gallic acid, gentisic acid, protocatechuic acid, 4-hydroxy benzoic acid, catechin hydrate, vanillic acid, caffeic acid, vanillin, p-coumaric acid, ferulic acid, myricetin, resveratrol, luteolin, naringenin, kaempferol. Major compound detected was catechin hydrate (28.305 mg 100 g -1 extract. The phenolic compounds of Pinus brutia extract and pycnogenol were compared, and it is shown that both of them consisted of considerable amount of phenolic compounds.

  6. Comparative pharmacokinetics of a proliposome formulation of Ginkgo biloba extract and Ginaton in rats by a sensitive ultra performance liquid chromatography-tandem mass spectrometry method.

    Science.gov (United States)

    Zheng, Bin; Xing, Gaoyang; Bi, Ye; Yan, Guodong; Wang, Jing; Cheng, Yingkun; Liu, Yan; Ashraf, Muhammad Aqeel; Xie, Jing

    2016-01-01

    As a novel oral drug delivery system, proliposome was applied to improve the solubility of active components of Ginkgo biloba extract (GbE). There are currently few reports focusing on the pharmacokinetic characteristics of proliposome of GbE (GbP). A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of active components of GbP and a commercial tablet product (Ginaton) in rat plasma was developed and successfully validated. The method was applied to the comparative pharmacokinetic evaluation of GbP and Ginaton in rat plasma. The results indicated that GbP has a significant effect on absorption, elimination and bioavailability of flavonoids and terpenoid lactones in comparison with Ginaton. The obtained results would be helpful for evaluating the absorption mechanism in the gastrointestinal tract in pharmacokinetic level and guiding the development of the novel oral drug delivery system.

  7. Determination of VX-G analogue in red blood cells via gas chromatography-tandem mass spectrometry following an accidental exposure to VX.

    Science.gov (United States)

    McGuire, Jeffrey M; Taylor, James T; Byers, Christopher E; Jakubowski, Edward M; Thomson, Sandra M

    2008-01-01

    A sensitive method for determining exposure to the chemical warfare agent VX is described in which the biomarker ethyl methylphosphonofluoridate (VX-G) is measured in red blood cells (RBCs) following treatment with fluoride ion using isotope-dilution gas chromatography-tandem mass spectrometry. The analyte was isolated via solid-phase extraction and detected using ammonia chemical ionization in the multiple reaction monitoring mode. A good linear relationship was obtained in the quantitative concentration range of 4 ng/mL to 1000 ng/mL with an absolute detection limit of VX vapor. Detection and quantitation of VX-G were possible in samples taken as late as 27 days following exposure.

  8. Kinetic study for a stress testing of L,L-ethylenedicysteine by ultra-performance liquid chromatography/tandem mass spectrometry analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sun Xiaotao [Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875 (China); Qiao Jinping, E-mail: Qiaojp920@gmail.co [Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875 (China); Zhu Lin; Qiao Hongwen [Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875 (China); Zhong Jianguo [National Institute for the Control of Pharmaceutical and Biological Products, Beijing 100050 (China)

    2010-12-15

    This study proposed a stress testing to study oxidative stability and estimate the potential shelf-life of L,L-ethylenedicysteine (L,L-EC) under normal storage temperature condition (20-25 {sup o}C). L,L-EC was detected as a function of time at four different temperatures by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). The degradation of L,L-EC followed the first order kinetics, and the temperature-dependent kinetics was well described by the linear Arrhenius equation. The activation energy (E{sub a}) was calculated, and the shelf-life at 25 and 4 {sup o}C was predicted. The results are useful for the proper storage and quality evaluation of L,L-EC.

  9. Comparison of different calibration approaches for chloramphenicol quantification in chicken muscle by ultra-high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Pan, Xiao-Dong; Jiang, Wei; Wu, Ping-Gu

    2015-01-07

    Matrix-dependent signal suppression often occurs in quantitative analysis by ultra-high pressure liquid chromatography tandem mass spectrometry (UPLC-MS/MS). In this study, we investigated three calibration methods for compensation of signal suppression on chloramphenicol (CAP) quantification in chicken muscle. The data showed that the spiking recoveries by solvent standard calibration with a stable isotope labelled internal standard (SIL-IS) and matrix-matched standard calibration with a SIL-IS were significantly higher than by external matrix-matched standard calibration (P 0.05). The limit of detection (LOD) for external matrix matched standard calibration was 0.1 μg kg(-1), and that for SIL-IS calibration (including matrix matched and solvent dissolved standard) was 0.03 μg kg(-1).

  10. Choline in infant formula and adult/pediatric nutritional Formula by ultra high-performance liquid chromatography/ Tandem mass spectrometry: AOAC First Action 2012.18.

    Science.gov (United States)

    Martin, Frederic; Gimenez, Catherine; Fontannaz, Patric; Kilinc, Tamara; Campos-Giménez, Esther; Dowell, Dawn

    2013-01-01

    The method described below is for the determination of choline in infant formula and adult/pediatric nutritional formula by ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The single-laboratory validation data were submitted to the Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Expert Review Panel (ERP) for review at the AOAC INTERNATIONAL Annual Meeting held September 30 to October 3, 2012 in Las Vegas, NV. The ERP determined that the data reviewed met the standard method performance requirements set by SPIFAN, and the method was approved as AOAC Official First Action. The analytical range was found to be between 0.16 and 3.2 microg/mL. The recovery rates were within 80-120% at 50 and 100% of native levels for all samples. Repeatability precision (RSDr) was < 3%, with intermediate reproducibility (RSDir) no higher than 4%.

  11. Rapid and easy multiresidue method for the analysis of antibiotics in meats by ultrahigh-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yamaguchi, Takahiro; Okihashi, Masahiro; Harada, Kazuo; Uchida, Kotaro; Konishi, Yoshimasa; Kajimura, Keiji; Hirata, Kazumasa; Yamamoto, Yoshimasa

    2015-06-03

    This study involved the development of a multiresidue method for the rapid analysis of 43 antibiotics in meats using ultrahigh-performance liquid chromatography-tandem mass spectrometry. This method was performed using dispersive-solid phase extraction, which is able to analyze 20 samples within 2 h. All compounds were determined simultaneously on a C18 separation column with gradient elution. Validation of the analytical method was performed by carrying out linearity, limit of quantification (LOQ), accuracy, precision, and recovery tests in different meat products. The validation criteria were set according to AOAC International and Japanese validation guidelines. The linearity of each compound was almost the coefficient of determination (r(2)) > 0.98. The LOQs of all tested antibiotics were chicken, respectively. This method can be used for rapid and easy multiresidue screening of antibiotics for three meats (pork, beef, and chicken).

  12. Enantioselective determination of methylphenidate and ritalinic acid in whole blood from forensic cases using automated solid-phase extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Thomsen, Ragnar; B. Rasmussen, Henrik; Linnet, Kristian

    2012-01-01

    A chiral liquid chromatography tandem mass spectrometry (LC–MS-MS) method was developed and validated for quantifying methylphenidate and its major metabolite ritalinic acid in blood from forensic cases. Blood samples were prepared in a fully automated system by protein precipitation followed...... methylphenidate was not determined to be related to the cause of death, the femoral blood concentration of d-methylphenidate ranged from 5 to 58 ng/g, and from undetected to 48 ng/g for l-methylphenidate (median d/l-ratio 5.9). Ritalinic acid was present at concentrations 10–20 times higher with roughly equal...... amounts of the d- and l-forms. In blood from 10 living subjects that were not suspected of being intoxicated by methylphenidate, the concentration ranges and patterns were similar to those of the postmortem cases. Thus, methylphenidate does not appear to undergo significant postmortem redistribution....

  13. Ultrasound-assisted emulsification microextraction for determination of 2,4,6-trichloroanisole in wine samples by gas chromatography tandem mass spectrometry.

    Science.gov (United States)

    Fontana, Ariel R; Patil, Sangram H; Banerjee, Kaushik; Altamirano, Jorgelina C

    2010-04-28

    A fast and effective microextraction technique is proposed for preconcentration of 2,4,6-trichloroanisole (2,4,6-TCA) from wine samples prior gas chromatography tandem mass spectrometric (GC-MS/MS) analysis. The proposed technique is based on ultrasonication (US) for favoring the emulsification phenomenon during the extraction stage. Several variables influencing the relative response of the target analyte were studied and optimized. Under optimal experimental conditions, 2,4,6-TCA was quantitatively extracted achieving enhancement factors (EF) > or = 400 and limits of detection (LODs) 0.6-0.7 ng L(-1) with relative standard deviations (RSDs) or = 0.9995. Validation of the methodology was carried out by standard addition method at two concentrations (10 and 50 ng L(-1)) achieving recoveries >80% indicating satisfactory robustness of the method. The methodology was successfully applied for determination of 2,4,6-TCA in different wine samples.

  14. Determination of Pesticide Residues in Honeybees using Modified QUEChERS Sample Work-Up and Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Żaneta Bargańska

    2014-03-01

    Full Text Available Increasing emissions of chemical compounds to the environment, especially of pesticides, is one of factors that may explain present honeybee colony losses. In this work, an analytical method employing liquid chromatography-tandem mass spectrometry (LC-MS/MS was optimized for the simultaneous screening of 19 pesticides which have not been yet determined in honeybee samples from northern Poland (Pomerania. The sample preparation, based on the QuEChERS method combining salting-out liquid-liquid extraction to acetonitrile and a dispersive-SPE clean-up, was adjusted to honeybee samples by adding a small amount of hexane to eliminate beeswax. The recovery of analytes ranged from 70% to 120% with relative standard deviation ≤20%. The limits of detection were in the range of 0.91–25 ng/g. A total of 19 samples of honeybees from suspected pesticide poisoning incidents were analyzed, in which 19 different pesticides were determined.

  15. Determination of (fluoro)quinolone antibiotic residues in pig kidney using liquid chromatography-tandem mass spectrometry. Part II: intercomparison exercise.

    Science.gov (United States)

    Toussaint, B; Chedin, M; Vincent, U; Bordin, G; Rodriguez, A R

    2005-09-23

    A recently in-house validated method for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination of eleven (fluoro)quinolone antibiotics (FQs) in pig kidney has been fully validated through an intercomparison exercise. This ring trial involved eight European laboratories and was based on the Commission Decision 2002/657/CE for validation of method and on the IUPAC protocol for method-performances studies. The laboratories data were submitted to a one-way analysis of variance. Satisfactory results were obtained for each FQ with regards to within- and between-laboratory reproducibility and accuracy. The method was validated for the simultaneous qualitative and quantitative determination of the eleven FQs in pig kidney around their maximum residue limit (MRL) as defined in the European Council Regulation 2377/90/EEC.

  16. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma.

    Science.gov (United States)

    Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang

    2005-03-25

    A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.

  17. Enantioselective determination of protein amino acids in fertilizers by liquid chromatography-tandem mass spectrometry on chiral teicoplanin stationary phase.

    Science.gov (United States)

    Taujenis, Lukas; Olšauskaitė, Vilma; Padarauskas, Audrius

    2014-11-19

    High-performance liquid chromatography on a glycopeptide antibiotic teicoplanin-based chiral stationary phase coupled with tandem mass spectrometry was developed for fast and reliable enantioseparation and determination of protein amino acids in hydrolyzed fertilizer samples. The effect of the mobile phase parameters (type and content of organic modifier and pH) and the column temperature on the enantioselectivity was investigated. Under optimized conditions, the majority (15 of 19) of d/l-amino acid pairs were resolved with a resolution factor (Rs) higher than 1.5 with a run time of 15 min. A triple quadrupole tandem mass spectrometer operating in multiple reaction monitoring mode with an electrospray ionization (ESI) ion source was employed for detection. The method was validated in terms of linearity, limits of detection, limits of quantitation, precision, and accuracy. Linear responses were obtained with determination coefficients higher than 0.998 for all analytes, and limits of detection were from 0.04 to 0.24 μg/mL. Sample spike/recovery experiments gave recovery values ranging from 73% for d-threonine to 116% for L-tryptophan. Relative standard deviations for inter- and intraday precision experiments were lower than 21.7%. The developed method was successfully applied for determination of the free amino acid enantiomers in five commercially available hydrolyzed protein fertilizer samples.

  18. Simultaneous Determination of Melamine, Ammelide, Ammeline, and Cyanuric Acid in Milk and Milk Products by Gas Chromatography-tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    HONG MIAO; SAI FAN; YONG-NING WU; LEI ZHANG; PING-PING ZHOU; JING-GUANG LI; HUI-JING CHEN; YUN-FENG ZHAO

    2009-01-01

    Objective To develop an analytical method for simultaneously qualitative and quantitative determination of melamine and triazine-related by-products including ammelide, ammeline, and cyanuric acid in milk and milk products by gas chromatography-tandem mass spectrometry (GC-MS/MS). Methods Melamine and triazine-related by-products namely ammelide, ammeline and cyanuric acid in the samples were extracted in a solvent mixture of diethylamine, water, and acetonitrile (10:40:50, V/V/V). After centrifugation, an aliquot of the supernatant was evaporated to dryness under a gentle stream of nitrogen gas, and then melamine and triazine-related by-products were derivatized using BSTFA with 1% TMCS. The derivatives of melamine and its analogues were determined by gas chromatography/ tandem mass spectrometry using multiple reactional monitoring (MRM) with 2, 6-Diamino-4-chloropyrimidine (DACP) being used as an internal standard. Results The linear detectable ranges were from 0.004 mg/kg to 1.6 mg/kg for melamine, ammelide, ammeline, and cyanuric acid with a correlation coefficient no less than 0.999. The recovery rates of the four compounds in spiked blank milk powder at concentrations 0.5, 1, 2 mg/kg were between 61.4%-117.2%, and the relative standard deviation was no more than 11.5% (n=6). The detection limits of melamine, ammelide, ammeline and cyanuric acid in milk powder were 0.002 mg/kg with a ratio of signal to noise of 3. Conclusion This GC-MS/MS method for simultaneous determination of melamine, ammelide, ammeline, and cyanuric acid in milk and milk products is sensitive and specific.

  19. [Determination of eight bisphenol diglycidyl ethers in water by solid phase extraction-high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Haijing; Lin, Shaobin

    2014-07-01

    A solid phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (SPE-HPLC-MS/MS) method was developed for the determination of eight bisphenol diglycidyl ethers, including bisphenol A diglycidyl ether (BADGE), bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether (BADGE x HCl), bisphenol A bis (3-chloro-2-hydroxypropyl) ether (BADGE x 2HCl), bisphenol A (2, 3-dihydroxypropyl) glycidyl ether (BADGE x H2O), bisphenol A bis(2,3-dihydroxypropyl) ether (BADGE x 2H2O), bisphenol A (3-chloro-2-hydroxypropyl) (2,3-dihydroxypropyl) ether (BADGE x HCl x H2O), bisphenol F diglycidyl ether (BFDGE) and bisphenol F bis (3-chloro-2-hydroxypropyl) ether (BFDGE 2HCl) in water. A total of ten samples were collected from the leaching of the coatings for drinking water supply system. Then, 200 mL exposure water was preconcentrated on C18 solid-phase extraction cartridge. The eight compounds were analyzed by liquid chromatography-tandem mass spectrometry method on a C18 column by the gradient elution with methanol, water and 5 mmol/L ammonium acetate as mobile phases in the multiple reaction monitoring (MRM) scan mode. The external matrix standard solutions were used for the quantitative determination and the calibration curves of the eight compounds showed good linearity in the range of 0.007-5.00 microg/L with the correlation coefficients more than 0.999 0. The limits of quantification (LOQs) of the method were 7-91 ng/L. The spiked recoveries ranged from 79.1% to 101% with the relative standard deviations of 4.0% - 12%. The method is sensitive and accurate, and is applicable to the determination of bisphenol diglycidyl ethers in water.

  20. A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction and ultra-performance liquid chromatography- tandem mass spectrometry.

    Science.gov (United States)

    Simonsen, Kirsten Wiese; Hermansson, Sigurd; Steentoft, Anni; Linnet, Kristian

    2010-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for detection of 23 benzodiazepines and related compounds in whole blood was developed and validated. The method is used for screening and quantitation of benzodiazepines in whole blood received from autopsy cases and living persons. The detected compounds were alprazolam, bromazepam, brotizolam, chlordiazepoxide, demoxepam, clobazam, clonazepam, 7-aminoclonazepam, diazepam, nordiazepam, estazolam, flunitrazepam, 7-aminoflunitrazepam, lorazepam, lormetazepam, midazolam, nitrazepam, 7-aminonitrazepam, oxazepam, temazepam, triazolam, zaleplon, and zopiclone. Whole blood from drug-free volunteers was used for all experiments. Blood samples (0.200 g) were extracted with ethyl acetate at pH 9. Target drugs were quantified using a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole in positive electrospray ionization, multiple reaction monitoring mode. The use of deuterated internal standards for most compounds verified that the accuracy of the method was not influenced by matrix effects. Extraction recoveries were 73-108% for all analytes. Lower limits of quantification ranged from 0.002 to 0.005 mg/kg. Long-term imprecision (CV%) ranged from 6.0 to 18.7%. We present a fully validated UPLC-MS-MS method for 23 benzodiazepines in whole blood with a run-time of only 5 min and using only 0.200 g of whole blood.

  1. The evaluation of the applicability of a high pH mobile phase in ultrahigh performance liquid chromatography tandem mass spectrometry analysis of benzodiazepines and benzodiazepine-like hypnotics in urine and blood

    OpenAIRE

    2012-01-01

    A sensitive liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous detection of benzodiazepines, benzodiazepine-like hypnotics and some metabolites (7-aminoflunitrazepam, alprazolam, bromazepam, brotizolam, chlordiazepoxide, chlornordiazepam, clobazam, clonazepam, clotiazepam, cloxazolam, diazepam, ethylloflazepate, flunitrazepam, flurazepam, loprazolam, lorazepam, lormetazepam, midazolam, N-desmethylflunitrazepam, nitrazepam, N-methylclonazepam (in...

  2. Detection of buffalo mozzarella adulteration by an ultra-high performance liquid chromatography tandem mass spectrometry methodology.

    Science.gov (United States)

    Russo, Rosita; Severino, Valeria; Mendez, Alberto; Lliberia, Josep; Parente, Augusto; Chambery, Angela

    2012-11-01

    Over the past years, LC-MS-based approaches have gained a growing interest in food analysis by using different platforms and methodologies. In particular, enhanced selectivity and sensitivity of multiple reaction monitoring (MRM) scan function offer powerful capabilities in detecting and quantifying specific analytes within complex mixtures such as food matrices. The MRM approach, traditionally applied in biomedical research, is particularly suitable for the detection of food adulteration and for the verification of authenticity to assure food safety and quality, both recognized as top priorities by the European Union Commission. Increasingly stringent legislation ensure products safety along every step 'from farm to fork', especially for traditional foods designed with the Protected Designation of Origin certification. Therefore, there is a growing demand of new methodologies for defining food authenticity in order to preserve their unique traits against frauds. In this work, an ultra performance liquid chromatopgraphy-electrospray ionization-tandem mass spectrometry (MS/MS) methodology based on MRM has been developed for the sensitive and selective detection of buffalo mozzarella adulteration. The targeted quantitative analysis was performed by monitoring specific transitions of the phosphorylated β-casein f33-48 peptide, identified as a novel species-specific proteotypic marker. The high sensitivity of MRM-based MS and the wide dynamic range of triple quadrupole spectrometers have proved to be a valuable tool for the analysis of food matrices such as dairy products, thus offering new opportunities for monitoring food quality and adulterations. Copyright © 2012 John Wiley & Sons, Ltd.

  3. A robust and rapid liquid chromatography tandem mass spectrometric method for the quantitative analysis of 5-azacytidine.

    Science.gov (United States)

    Anders, Nicole M; Wanjiku, Teresia M; He, Ping; Azad, Nilofer S; Rudek, Michelle A

    2016-03-01

    The DNA methyltransferase inhibitor 5-azacytidine is being evaluated clinically as an oral formulation to treat various solid tumors. A sensitive, reliable method was developed to quantitate 5-azacytidine using LC-MS/MS to perform detailed pharmacokinetic studies. The drug of interest was extracted from plasma using Oasis MCX ion exchange solid-phase extraction 96-well plates. Chromatographic separation was achieved with a YMC J'sphere M80 C18 column and isocratic elution with a methanol-water-formic acid (15:85:0.1, v/v/v) mobile phase over a 7 min total analytical run time. An AB Sciex 5500 triple quadrupole mass spectrometer operated in positive electrospray ionization mode was used for the detection of 5-azacytidine. The assay range was 5-500 ng/mL and proved to be accurate (97.8-109.1%) and precise (CV ≤ 9.8%). Tetrahydrouridine was used to stabilize 5-azacytidine in blood/plasma samples. With the addition of tetrahydrouridine, long-term frozen plasma stability for 5-azacytidine at -70°C has been determined for at least 323 days. The method was applied for the measurement of total plasma concentrations of 5-azacytidine in a cancer patient receiving a 300 mg oral daily dose. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Qualitative and quantitative determination of 15 main active constituents in Fructus Sophorae pill by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Xu-ran Zhi

    2015-01-01

    Full Text Available Background: Fructus Sophorae pill, one of the traditional Chinese medicine, was widely used for hemorrhoids, hypertension and odontalgia. This paper describes a sensitive and specific assay for the determination of the 15 active constituents (sophoricoside, genistin, genistein, rutin, quercetin, kaempferol, baicalein, baicalin, naringin, naringenin, hesperidin, neohesperidin, wogonin and cimifugin, prim-O-glucosylcimifugin in Fructus Sophorae pill. Materials and Methods: Chromatographic separation was performed on a C 18 column with acidified aqueous methanol gradients at a flow rate of 0.8 mL/min. The identification and quantification of the analytes were achieved by use of a hybrid quadrupole linear ion trap mass spectrometer. Multiple-reaction monitoring scanning was applied to quantification with switching electrospray ion source polarity between positive and negative modes. Results: The proposed method was used to analyze 40 batches of samples with good linearity (r, 0.9990-0.9999, intraday precisions (RSD, 0.14-2.55%, interday precisions (RSD, 0.51-2.81%, stability (RSD, 0.31-2.65%, and recovery (RSD, 1.29-2.95% of the 15 compounds. In addition, the hierarchical cluster analysis, including a method called furthest neighbor and nearest neighbor, was employed to classify samples according to characteristics of the 15 constituents. Conclusion: The results indicated that the analytical method was rapid, reliable, simple and suitable for the quality evaluation of Fructus Sophorae pill.

  5. Determination of endocrine-disrupting compounds in drinking waters by fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Magi, Emanuele; Scapolla, Carlo; Di Carro, Marina; Liscio, Camilla

    2010-09-01

    Growing attention has been recently paid to safety of food and drinking water, making necessary the adoption of policies for water sources protection and the development of sensitive and rapid analytical methods to identify micropollutants. Endocrine-disrupting compounds (EDCs) have emerged as a major issue as they alter the functioning of the endocrine system. Since ingestion of EDCs via food is considered the major exposure route, there is a growing interest in understanding EDC fate during drinking water treatment and in monitoring potential contamination of surface waters and groundwaters. In this work, a fast liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed for the determination of 4-n-nonylphenol (NP), bisphenol A (BPA), estrone (E1), 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in drinking waters. In the literature analytical articles seldom provide details regarding fragmentation pathways. In this paper spectra of the five EDCs in negative ESI were interpreted with the support of accurate mass spectra acquired by a quadrupole time-of-flight instrument; fragmentation pathways were also proposed. The chromatographic separation of EDCs was optimized on a Pinnacle DB Biphenylic column with a water-acetonitrile gradient. Quantitative analysis was performed in multiple reaction monitoring (MRM) mode using bisphenol A-d(16) (BPA-d(16)) as internal standard; calibration curves showed good correlation coefficients (0.9989-0.9997). All figures of merit of the method were satisfactory; limits of detection were in the range 0.2-0.4 ng/ml. The method was applied to the determination of the analytes in waters sampled by polar organic chemical integrative samplers in a drinking water treatment plant. Rather low concentration of BPA, NP and E1 were measured in the inlet, while none of the considered EDCs was detected in the outlet. 2010 John Wiley & Sons, Ltd.

  6. Determination of Clarithromycin in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Validation and Application in Clinical Pharmacokinetic Study

    Institute of Scientific and Technical Information of China (English)

    ZHANGXiang-rong; CHENXiao-yan; LIXiao-yan; ZHONGDa-fang

    2004-01-01

    Aim To develop a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method to determine clarithromycin in human plasma. Methods The analyte and internal standard roxithromycin were extracted from plasma samples by n-nexane-dichloromethane-isopropanel (300:150:15, V/V/V) and chromatographed on a C18 column. The mobile phase consisted of methanol-water-formic acid (80:20:1, V/V/V). Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization source (ESI) in the positive mode. Results The method had a lower limit of quantification of 10.0 ng·mL-1 when 0.2 mL plasma was used. The linear calibration curves were obtained in the concentration range of 10.0-5000 ng·mL-1. The intra-and inter-rum precisions were lower than 3.3% in terms of relative standard deviation (RSD), and the accuracy ranged±0.7% in terms of relative error (RE). Tmax, Cmax, T1/2 and AUC0-24h values were found to be (3.1±2.7)h, (8 750±4 734)ng·mL-1, (5.3±2.2)h, and (5932±2 449)ng·mL-1, respectively, after a single oral dose of 250 mg clarithromycin tablet to 18 volunteers. Conclusion This validated method was successful in the evaluation of pharmacokinetic profiles of clarithromycin tablets administered to 18 healthy male volubteers.

  7. Assesment of endocrinal and biochemical entities through liquid chromatography-tandem mass spectrometry/mass spectrometer: Inter-relative investigation of the interaction based cardiovascular formulation

    Directory of Open Access Journals (Sweden)

    Rakesh Das

    2015-01-01

    Full Text Available Background: Combinatory oral dosage treatment of atorvastatin (ATVS and olmesartan (OLM drugs to cardiovascular patients reflects unpredicted results instead of its individual therapy, which was accessed on quantification of endocrinal and biochemicals of plasma through liquid chromatography-tandem mass spectrometry/mass spectrometer (LCMS/MS. Objective: Mission was to track the remarkable biochemical variation in the plasma after induction of the combined formulation, to evaluate the pharma-market rumor on its efficiency. Methods: To fulfil undergoing research objectives for digging-up of market insult, human patient volunteers were chosen according to the required criteria along with bioethical regulation. A sensitive, rapid and precise method was developed and validated to estimate aldosterone (ALD, angiotensin (ANG-II and the Mevalonate (MVA not Mevalonic acid through LCMS/MS over least samples of cardiovascular patients. Level of each endogenous biochemicals were determined in three stages - without drugs, with a single drug (OLM/ATVS and with their combination that was then correlate with blood pressure of respective volunteers. Result and Discussion: Comparative and correlative studies panaroma among these analytes was detected. The selectivity, specificity, linearity, precision, accuracy, extraction recovery, limit of detection and limit of quantification, stability were the essential points of validation of the developed methodology. And the significance of each endogenous analyte data were based on P ≥ 0.001. Thus, low value of ALD and reciprocally higher in ANG-II on administered single drug than its combination and equal concentration of mevalonate in both stages, was discovered. Conclusion: This concludes that the cardiovascular dosage formulation entrenched in the market are not synergistic and effective compared with a single drug as antihypertensive drug.

  8. Rapid methods to determine procyanidins, anthocyanins, theobromine and caffeine in rat tissues by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Serra, Aida; Macià, Alba; Romero, Maria-Paz; Piñol, Carme; Motilva, Maria-José

    2011-06-01

    Rapid, selective and sensitive methods were developed and validated to determine procyanidins, anthocyanins and alkaloids in different biological tissues, such as liver, brain, the aorta vein and adipose tissue. For this purpose, standards of procyanidins (catechin, epicatechin, and dimer B(2)), anthocyanins (cyanidin-3-glucoside and malvidin-3-glucoside) and alkaloids (theobromine, caffeine and theophylline) were used. The methods included the extraction of homogenized tissues by off-line liquid-solid extraction, and then solid-phase extraction to analyze alkaloids, or microelution solid-phase extraction plate for the analysis of procyanidins and anthocyanins. The eluted extracts were then analyzed by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry, using a triple quadrupole as the analyzer. The optimum extraction solution was water/methanol/phosphoric acid 4% (94/4.5/1.5, v/v/v). The extraction recoveries were higher than 81% for all the studied compounds in all the tissues, except the anthocyanins, which were between 50 and 65% in the liver and brain. In order to show the applicability of the developed methods, different rat tissues were analyzed to determine the procyanidins, anthocyanins and alkaloids and their generated metabolites. The rats had previously consumed 1g of a grape pomace extract (to analyze procyanidins and anthocyanins) or a cocoa extract (to analyze alkaloids) per kilogram of body weight. Different tissues were extracted 4h after administration of the respective extracts. The analysis of the metabolites revealed a hepatic metabolism of procyanidins. The liver was the tissue which produced a greater accumulation of these metabolites.

  9. Determination of pesticide residues in olives by liquid extraction surface analysis followed by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Gómez-Almenar, M. C.

    2015-06-01

    Full Text Available Nowadays, pesticides are essential in modern agriculture for crop protection, however, this use supposes a potential risk for human health and the environment. Traditional techniques of pesticide determination require the use of laborious and complex extraction methods to separate pesticides from the matrix, above all in fatty matrices like olives. For this reason, a new simple, rapid, cheap and selective method for the extraction and quantification of the most frequently used pesticides in olive growing has been developed. Pesticide determination was carried out by ultra-performance liquid chromatography (UPLC coupled with triple-quadrupole tandem mass spectrometry (MS/MS. Mean recoveries were found in a range between 73 and 114% with relative standard deviations lower than 20% in most pesticides evaluated and the limits of detection (LODs and quantification (LOQs were lower than 4 μg· kg-1 and 8 μg· kg-1, respectively. Finally, this method was applied to the analysis of 25 olive samples where Dimethoate and Terbuthylazine were detected in some cases, but their results were lower than 15 μg· kg-1.Hoy en día los pesticidas son esenciales en la agricultura moderna para la protección de los cultivos pero su uso supone un riesgo para la salud y el medio ambiente. Las técnicas tradicionales de determinación de pesticidas requieren el uso de métodos de extracción complejos a fin de separar los pesticidas de la matriz, sobre todo en matrices grasas como las aceitunas. Por ello, se ha desarrollado un nuevo método simple, rápido, barato y selectivo para la extracción y cuantificación de los pesticidas más frecuentemente utilizados en el cultivo del olivo, empleando cromatografía líquida de ultra-resolución (UPLC acoplada a espectrometría de masas (MS/MS. Las recuperaciones alcanzadas variaron entre el 73 y 114% obteniendo desviaciones estándar relativas inferiores al 20%. Los límites de detección (LD y cuantificación (LQ fueron

  10. Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma by ultra high performance liquid chromatography tandem mass spectrometry and its application to a bioequivalence study.

    Science.gov (United States)

    Qiu, Xiangjun; Wang, Zhe; Wang, Bing; Zhan, Hui; Pan, Xiaofeng; Xu, Ren-ai

    2014-04-15

    An ultra high performance liquid chromatography tandem mass spectrometry (U-HPLC-MS/MS) method was developed and validated to determine irbesartan (IRB) and hydrochlorothiazide (HCTZ) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard losartan were separated on an Acquity U-HPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the negative ion mode. The MRM transitions of m/z 427.2→206.9 and m/z 296.1→204.9 were used to quantify for IRB and HCTZ, respectively. The linearity of this method was found to be within the concentration range of 5-3000ng/mL for IRB, and 0.5-300ng/mL for HCTZ in human plasma, respectively. The lower limit of quantification (LLOQ) was 5ng/mL and 0.5ng/mL for IRB and HCTZ in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 12% for both IRB and HCTZ. The analysis time of per sample was 2.5min. The developed and validated method was successfully applied to a bioequivalence study of IRB (300mg) with HCTZ (12.5mg) tablet in Chinese healthy volunteers (N=20).

  11. Ultra high performance liquid chromatography tandem mass spectrometry determination and profiling of prohibited steroids in human biological matrices. A review.

    Science.gov (United States)

    Gosetti, Fabio; Mazzucco, Eleonora; Gennaro, Maria Carla; Marengo, Emilio

    2013-05-15

    so that, notwithstanding the generally high instrumental costs, the cost of the individual assay is affordable. In addition, the improved specificity and resolution offered by time-of-flight or quadrupole time-of-flight mass spectrometry allow their application in doping control analysis or in steroid profiling for accurate and sensitive full mass range acquisition. Aim of the present review is to consider, compare and discuss the applications of the UHPLC/MS methods present in literature for the identification and determination of forbidden steroids and their metabolites in human biological matrices.

  12. Analysis of cortisol, cortisone and dexamethasone in human serum using liquid chromatography tandem mass spectrometry and assessment of cortisol: cortisone ratios in patients with impaired kidney function.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2011-06-11

    We developed a high sensitivity method for simultaneous measurement of cortisol, cortisone and dexamethasone. Using this method, we compared concentrations of cortisol, cortisone and their ratios in samples from intensive care unit (ICU) and non-ICU patients, and cortisol and dexamethasone concentrations in patients with Cushing's and suspected Cushing's syndrome. Two hundred microliters of human serum aliquots were extracted using solid phase extraction and analyzed using liquid chromatography-tandem mass spectrometry. Primary mass transitions monitored for cortisol, cortisone and dexamethasone were m/z 363/121, 361/163 and 393/373 respectively. The limits of quantification for cortisol and cortisone were 0.3 μg/l (0.8 nmol/l) and for dexamethasone it was 0.5 μg/l (1.2 nmol/l). Total imprecision was cortisone ratio of ICU patient samples was found to be 2 times higher than non-ICU samples. 54.2% of patients after 1mg dose of overnight dexamethasone could be categorized as consistent with Cushing's syndrome. The method has high sensitivity and specificity. High cortisol to cortisone ratios in samples from ICU patients suggest change in activity of 11β-hydroxysteroid dehydrogenase in modulation of systemically available cortisol. Simultaneous measurement of dexamethasone and cortisol can be used to differentially diagnose diseases causing increased concentrations of cortisol. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of nine corticosteroid residues in bovine liver samples

    Energy Technology Data Exchange (ETDEWEB)

    Dusi, Guglielmo, E-mail: guglielmo.dusi@izsler.it [Istituto Zooprofilattico Sperimentale della Lombardia e dell' Emilia Romagna, ' B. Ubertini' , Via Bianchi 9, 25124 Brescia (Italy); Gasparini, Mara; Curatolo, Michele; Assini, Walter; Bozzoni, Eros; Tognoli, Nadia; Ferretti, Enrica [Istituto Zooprofilattico Sperimentale della Lombardia e dell' Emilia Romagna, ' B. Ubertini' , Via Bianchi 9, 25124 Brescia (Italy)

    2011-08-26

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CC{alpha}), detection capability (CC{beta}) and ruggedness. All the corticosteroids can be detected at a concentration around 1 {mu}g kg{sup -1}; the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.

  14. [Determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhu, Feng

    2015-01-01

    A method has been developed for the determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds (DHTDMAC) in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry. (UPLC-MS/MS). The samples were extracted and diluted with acidified methanol by 5% (v/v) formic acid under ultrasonic assistance. The separation was performed on an Eclipse Plus C18 column (50 mm x 2.1 mm, 1.8 microm) using 0.1% (v/v) formic acid solution and methanol as the mobile phases. Identification and quantification were achieved by UPLC-MS/MS with electrospray ionization (ESI) source in positive ion mode and multiple reaction monitoring (MRM) mode. The results indicated that the calibration curve of DHTDMAC showed good linear relationship between peak area and mass concentration in the range of 10-280 microg/L with the correlation coefficient (r2) of 0.9991. The limit of detection (LOD, S/N=3) and the limit of quantification (LOQ, S/N= 10) of this method were 3 mg/kg and 10 mg/kg, respectively. The average recoveries from three typical textile auxiliary matrices including dispersant, antistatic agent and fabric softener, at three spiked levels were in the range of 97.2%-108.3% with the relative standard deviations (RSDs) of 1.5%-4.6%. The method is sensitive, accurate, simple and effective for the analysis of DHTDMAC in textile auxiliaries.

  15. [Simultaneous determination of zeranols and chloramphenicol in foodstuffs of animal origin by combination immunoaffinity column clean-up and liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wang, Qing; Wang, Guomin; Xi, Cunxian; Li, Xianliang; Chen, Dongdong; Tang, Bobin; Zhang, Lei; Zhao, Hua

    2014-06-01

    A combination immunoaffinity column (IAC-CZ) clean-up and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method was successfully developed for zearalenol, beta-zearalenol and zearalenone) and chloramphenicol (CAP) in foodstuffs of animal origin. The samples (fish, liver, milk and honey) were enzymatically digested by beta-glucuronidase/sulfatase for about 16 h and then extracted with ether. The extracts were evaporated to dryness and then the residues were dissolved by 1.0 mL of 50% acetonitrile solution. After filtered and diluted with PBS buffer, the reconstituted solution were cleaned-up with a IAC-CZ and then analyzed by LC-MS/MS in multiple reaction monitoring (MRM) mode. The chromatographic separation was performed on a Shimadzu Shim-pack VP-ODS column with gradient elution by acetonitrile and 2 mmol/L ammonium acetate solution. The detection was carried out by electrospray negative ionization mass spectrometry in MRM mode. The proposed method was validated by the limit of detection (0.04-0.10 microg/kg), linearity (R2 > or = 0.999 0), average recoveries (70.9%-95.6%) and precisions (2.0% - 11.8%). The developed method is reliable, sensitive and has good applicability. The combination immunoaffinity column was proved to be an effective pretreatment technique to decrease the matrix effect, and it met the requirements of residue analysis of co-occurring zeranols and chloramphenicol.

  16. Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay for the determination of sanfetrinem in human plasma.

    Science.gov (United States)

    De Nardi, C; Braggio, S; Ferrari, L; Fontana, S

    2001-10-25

    A rapid, selective and accurate high-performance liquid chromatography-tandem mass spectrometry assay for the quantification of sanfetrinem in human plasma has been developed and validated. The performance of manual and automated sample preparation was assessed; 50 microl of plasma sample was deproteinized with acetonitrile, followed by dilution with water and injection onto the LC system. Chromatographic separation was achieved on a Phenomenex Luna C18(2), 50x2.0 (5 microm) column with a mobile phase consisting of water-acetonitrile with 0.1% formic acid followed by detection with a Perkin-Elmer API3000 mass spectrometer in multiple reaction monitoring mode. The lower limit of quantification was improved by five times compared to the UV method previously reported. A range of concentration from 10 ng/ml to 5 microg/ml was covered. The method was applied to the quantification of sanfetrinem in human plasma samples from healthy volunteers participating in a clinical study.

  17. Micro-solid phase extraction with liquid chromatography-tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage.

    Science.gov (United States)

    Khayoon, Wejdan Shakir; Saad, Bahruddin; Salleh, Baharuddin; Manaf, Normaliza Hj Abdul; Latiff, Aishah A

    2014-03-15

    A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography-tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20mg; extraction time, 90 min; stirring speed, 1,000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1, AFB2 and AFB1, respectively were achieved. Good linearity and correlation coefficient was obtained over the concentration range of 0.4-50 ng g(-1) (r(2) 0.9988-0.9999). Good recoveries for AFs ranging from 86.0-109% were obtained. The method was applied to 40 samples involving malt beverage (19) and canned coffee (21). No AFs were detected in the selected samples.

  18. [Simultaneous determination of 11 quinolones in hotpot ingredients by dispersive solid-phase extraction and ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Cao, Peng; Mou, Yan; Gao, Fei; Geng, Jinpei; Zhang, Xiqing; Sui, Tao; Liang, Junni; Sha, Meilan; Guan, Lili

    2013-09-01

    A method for the simultaneous determination of the residues of 11 quinolones in hotpot ingredients by quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction and ultra performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) was established. The sample was extracted with acetonitrile (containing 5% formic acid) and followed by stratifying with a salting-out agent. Clean-up of the extracts was processed by C18 and PSA, a modified QuEChERS procedure. The analytes were then separated on a Poroshell 120 EC-C18 column, and finally detected by tandem mass spectrometry in positive ESI mode. The linearity of all the 11 quinolones in the range from 1.0 to 100.0 microg/kg had correlation coefficients greater than 0.998. The limits of detection (LOD) of the method were from 1.8 to 3.1 microg/kg and the limits of quantification (LOQ) were from 6.0 to 10.3 microg/kg. The average recoveries of the 11 quinolones were in the range from 70.1% to 100.3%, with relative standard deviations from 2.42% to 10.88%. The established method is sensitive and of good recoveries. It can be applied as a rapid and reliable method for the determination of the 11 quinolones in hotpot ingredients.

  19. Simple quantitative determination of potent thiols at ultratrace levels in wine by derivatization and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis.

    Science.gov (United States)

    Capone, Dimitra L; Ristic, Renata; Pardon, Kevin H; Jeffery, David W

    2015-01-20

    Volatile sulfur compounds contribute characteristic aromas to foods and beverages and are widely studied, because of their impact on sensory properties. Certain thiols are particularly important to the aromas of roasted coffee, cooked meat, passion fruit, grapefruit, and guava. These same thiols enhance the aroma profiles of different wine styles, imparting pleasant aromas reminiscent of citrus and tropical fruits (due to 3-mercaptohexan-1-ol, 3-mercaptohexyl acetate, 4-mercapto-4-methylpentan-2-one), roasted coffee (2-furfurylthiol), and struck flint (benzyl mercaptan), at nanogram-per-liter levels. In contrast to the usual gas chromatography (GC) approaches, a simple and unique high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for routine analysis of five wine thiols, using 4,4'-dithiodipyridine (DTDP) as a derivatizing agent and polydeuterated internal standards for maximum accuracy and precision. DTDP reacted rapidly with thiols at wine pH and provided stable derivatives, which were enriched by solid-phase extraction (SPE) prior to analysis by HPLC-MS/MS. All steps were optimized and the method was validated in different wine matrices, with method performance being comparable to a well-optimized but more cumbersome gas chromatography-mass spectrometry (GC-MS) method. A range of commercial wines was analyzed with the new method, revealing the distribution of the five thiols in white, red, rosé, and sparkling wine styles.

  20. QuEChERS Purification Combined with Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry for Simultaneous Quantification of 25 Mycotoxins in Cereals

    Science.gov (United States)

    Sun, Juan; Li, Weixi; Zhang, Yan; Hu, Xuexu; Wu, Li; Wang, Bujun

    2016-01-01

    A method based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) purification combined with ultrahigh performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS), was optimized for the simultaneous quantification of 25 mycotoxins in cereals. Samples were extracted with a solution containing 80% acetonitrile and 0.1% formic acid, and purified with QuEChERS before being separated by a C18 column. The mass spectrometry was conducted by using positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) models. The method gave good linear relations with regression coefficients ranging from 0.9950 to 0.9999. The detection limits ranged from 0.03 to 15.0 µg·kg−1, and the average recovery at three different concentrations ranged from 60.2% to 115.8%, with relative standard deviations (RSD%) varying from 0.7% to 19.6% for the 25 mycotoxins. The method is simple, rapid, accurate, and an improvement compared with the existing methods published so far. PMID:27983693

  1. Determination of a dipeptidyl peptidase IV agonist, β-aminoacyl containing thiazolidine derivatives (KR-66223) in rat plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kim, Min-Sun; Park, Jong-Shik; Jang, Su-Min; Lee, Byung Hoi; Ahn, Sung-Hoon; Ahn, Jin Hee; Yoo, Sung Eun; Song, Im-Sook; Silinski, Peter; Schneider, Stephen Edward; Bae, Myung Ae

    2011-07-15

    A sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for a novel dipeptidyl peptidase IV agonist (DDP-IV) agonist, KR-66223, in rat plasma. It involves liquid-liquid extraction (LLE) followed by HPLC separation and electrospray ionization tandem mass spectrometry. KR-66223 and imipramine (IS) was separated on Gemini-NX C18 column with mixture of acetonitrile-ammonium formate (10mM) (90:10, v/v) as mobile phase. The ion transitions monitored were m/z 553.2→206.2 for KR-66223, m/z 281.3→86.1 for imipramine in multiple reaction monitoring (MRM) mode. The linear ranges of the assay were 0.003-10μg/ml with a correlation coefficient (R(2)) greater than 0.99 and the lower limit of quantification was 3ng/ml. The average recovery was 78.9% and 87.1% from rat plasma for KR-66223 and imipramine, respectively. The coefficients of variation of intra- and inter-assay were 3.9-14.4% and the relative error was 0.8-11.5%. The method was validated and successfully applied to the pharmacokinetic study of KR-66223 in rat.

  2. Simultaneous determination of polycyclic musks in blood and urine by solid supported liquid-liquid extraction and gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Liu, Hongtao; Huang, Liping; Chen, Yuxin; Guo, Liman; Li, Limin; Zhou, Haiyun; Luan, Tiangang

    2015-06-15

    A rapid, precise and accurate method for the simultaneous determination of 5 polycyclic musks (PCMs) in biological fluids was developed by solid supported liquid-liquid extraction (SLE) coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS). All parameters influencing SLE-GC-MS performance, including electron energy of electron-impact ionization source, collision energy for tandem mass spectrometer when operated in selected-reaction monitoring (SRM) mode, type and volume of elution reagent, nitrogen evaporation time, pH and salinity of sample have been carefully optimized. Eight milliliter of n-hexane was finally chosen as elution reagent. Blood and urine sample could be loaded into SLE cartridge without adjusting pH and salinity. Deuterated tonalide (AHTN-d3) was chosen as internal standard. The correlation coefficient (r(2)) of the calibration curves of target compounds ranged from 0.9996 to 0.9998. The dynamic range spanned over two orders of magnitude. The limit of detection (LOD) of target compounds in blood and urine ranged from 0.008 to 0.105μgL(-1) and 0.005 to 0.075μgL(-1), respectively. The developed procedure was successfully applied to the analysis of PCMs in human blood and urine obtaining satisfying recoveries on low, medium and high levels. The method was compared with SLE-GC-MS and shown one to two orders of magnitude improvement in sensitivity.

  3. Liquid chromatography-tandem mass spectrometry simultaneous determination of repaglinide and metformin in human plasma and its application to bioequivalence study.

    Science.gov (United States)

    Liang, Xiao-Rong; Dai, Xiao-Jian; Zhang, Yi-Fan; Ding, Jue-Fang; Chen, Xiao-Yan; Zhong, Da-Fang

    2013-04-01

    A simple, sensitive, selective, and reproducible liquid chromatography-tandem mass spectrometric method was developed for the simultaneous determination of repaglinide and metformin in human plasma using d5-repaglinide and d6-metformin as internal standards (ISs). After a simple protein precipitation using acetonitrile as the precipitation solvent, both analytes and ISs were separated on a Venusil ASB C 18 (150 mm x 4.6 mm, 5 microm) via gradient elution using acetonitrile--10 mmol x L(-1) ammonium acetate as the mobile phase. A chromatographic total run time of 7.5 min was achieved. Mass spectrometric detection was conducted with atmospheric pressure chemical ionization under positive-ion and multiple-reaction monitoring modes. The method was linear over the 0.2 to 60.0 ng x mL(-1) concentration range for repaglinide and over the 4 to 1 000 ng x mL(-1) range for metformin. For both analytes, the intra- and inter-accuracies and precisions were within the +/- 15% acceptable limit across all concentrations. The validated method was successfully applied to a clinical bioequivalence study.

  4. [Determination of carcinogenic aromatic amines derived from azo colorants in textiles and leather by ultra high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wen, Yuyun; Ou, Yan; He, Mingchao; Gong, Zhenbin

    2013-04-01

    A rapid determination method was developed for the quantification and confirmation of 22 carcinogenic aromatic amines derived from azo colorants in textiles and leather by ultra high performance liquid chromatography-tandem electrospray ionization mass spectrometry (UHPLC-MS/MS). The methods of EN 14362-1:2012 (for textiles) and ISO 17234-1:2010 (for leather) were adopted for sample pretreatment, finally diluted with methanol. The target compounds were separated by an Eclipse XDB-C18 RRHD column and eluted with methanol and water in gradient, and then determined by positive electrospray ionization mass spectrometry under multiple reaction monitoring (MRM) mode. The external standard method was used for the quantitative analysis. The separation conditions, fragment voltages, collision energies, etc. were optimized. The limits of quantification (LOQ) were below 0.2 mg/kg for different compounds, matrix spike recoveries ranged from 70% to 120% at the spiked levels of 500, 1 000 and 1 500 microg/L, and the relative standard deviations (RSDs) were less than 15%. The proposed method is rapid, sensitive, accurate and selective.

  5. Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Caffeine in Caffeine-Laced Pants and in Urine and Skin of a Pants User

    Directory of Open Access Journals (Sweden)

    Manuela Pellegrini

    2014-04-01

    Full Text Available A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the measurement of caffeine in caffeine-laced pants and in urine and skin of a pants user. The substance and its internal standard (N-ethylnorcotinine were separated by reversed phase chromatography with 5 mM ammonium formate pH 3.0 and 0.3% formic acid in acetonitrile mobile phase (83:17 v/v by isocratic elution and detected by tandem mass spectrometry operated in multiple reaction monitoring mode via positive electrospray ionization. Linearity was studied from 1.4 to100 ng/mL range for urine, from 5 to 100 ng/cotton swab for skin caffeine and from 1.3 to 100 µg/samples for 4 cm2 textile samples. Good determination coefficients (r2 = 0.99 were found in all cases. At three concentrations spanning the linear dynamic ranges of different samples mean recoveries of caffeine were always higher than 80% and intra-assay and inter-assay imprecision and inaccuracy were always better than 105%. For the first time, caffeine content in this cosmetotextile was determined together with the measurement of caffeine released on the user skin, the absorbed amount with resulting urinary concentrations.

  6. Development of a Method for the Quantitation of Three Thiols in Beer, Hop, and Wort Samples by Stir Bar Sorptive Extraction with in Situ Derivatization and Thermal Desorption-Gas Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ochiai, Nobuo; Sasamoto, Kikuo; Kishimoto, Toru

    2015-08-05

    A method for analysis of hop-derived polyfunctional thiols, such as 4-sulfanyl-4-methylpentan-2-one (4S4M2Pone), 3-sulfanylhexan-1-ol (3SHol), and 3-sulfanylhexyl acetate (3SHA), in beer, hop water extract, and wort at nanogram per liter levels was developed. The method employed stir bar sorptive extraction with in situ derivatization (der-SBSE) using ethyl propiolate (ETP), followed by thermal desorption and gas chromatography-tandem mass spectrometry (TD-GC-MS/MS) with selected reaction monitoring (SRM) mode. A prior step involved structural identification of the ETP derivatives of the thiols by TD-GC-quadrupole-time-of-flight mass spectrometry with parallel sulfur chemiluminescence detection (Q-TOF-MS/SCD) after similar der-SBSE. The der-SBSE conditions of the ETP concentration, buffer concentration, salt addition, and extraction time profiles were investigated, and the performance of the method was demonstrated with spiked beer samples. The limits of detection (LODs) (0.19-27 ng/L) are below the odor threshold levels of all analytes. The apparent recoveries at 10-100 ng/L (99-101%) and the repeatabilities [relative standard deviation (RSD) of 1.3-7.2%; n = 6] are also good. The method was successfully applied to the determination of target thiols at nanogram per liter levels in three kinds of beer samples (hopped with Cascade, Citra, and Nelson Sauvin) and the corresponding hop water extracts and wort samples. There was a clear correlation between the determined values and the characteristics of citrus hop aroma for each sample.

  7. Chiral analysis of amphetamines in hair by liquid chromatography-tandem mass spectrometry: compliance-monitoring of attention deficit hyperactivity disorder (ADHD) patients under Elvanse® therapy and identification after controlled low-dose application.

    Science.gov (United States)

    Binz, Tina M; Williner, Elena; Strajhar, Petra; Dolder, Patrick C; Liechti, Matthias E; Baumgartner, Markus R; Kraemer, Thomas; Steuer, Andrea E

    2017-04-24

    Amphetamine (AMP) is used as an illicit drug and also for the treatment of attention deficit hyperactivity disorder (ADHD). Respective drugs most often contain the enantiomer (S)-AMP as active compound or (S)-AMP is formed from the prodrug lisdexamfetamine (Elvanse®) whereas the illicit drug is usually traded as racemate ((R/S)-AMP). A differentiation between the use of the medically prescribed drug and the abuse of illicit street amphetamine is of great importance, for example in retrospective consumption monitoring by hair analysis. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the chiral separation and quantitation of (S)- and (R)-AMP in hair was developed. For this purpose, 20 mg hair was extracted and derivatized with N-(2,4-dinitro-5-fluorophenyl)-L(S)-valinamide L(S)-(DNPV) to yield amphetamine diastereomers. Baseline separation of the resulting diastereomers was achieved on a high-pressure liquid-chromatography system (HPLC) coupled to a Sciex QTRAP® 5500 linear ion trap quadrupole mass spectrometer. The method was successfully validated. Analysis of hair samples from nine Elvanse® patients revealed only (S)-AMP in eight cases; one subject showed both enantiomers indicating a (side-) consumption of street amphetamine. The analysis of the 16 amphetamine users' samples showed only racemic amphetamine. Furthermore, it could be shown in a controlled study that (S)-AMP can be detected after administration of even very low doses of lisdexamfetamine and dexamphetamine, which can be of interest in forensic toxicology and especially in drug-facilitated crime (DFC). The method now enables the retrospective compliance-monitoring of ADHD patients and the differentiation between medically prescribed intake of (S)-amphetamine and abuse of illicit street amphetamine. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Highly sensitive and rapid ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of nifedipine in human plasma and its application to a bioequivalence study.

    Science.gov (United States)

    Patel, Daxesh P; Sharma, Primal; Sanyal, Mallika; Singhal, Puran; Shrivastav, Pranav S

    2012-12-01

    An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed for the determination of nifedipine in human plasma using nifedipine-d6 as the internal standard (IS). The plasma samples were prepared by solid-phase extraction on Phenomenex Strata-X cartridges employing 200 μL human plasma. Chromatography was carried out on Waters Acquity UPLC BEH C₁₈ (50 × 2.1 mm, 1.7 µm particle size) analytical column under isocratic conditions using a mobile phase consisting of 4.0 mm ammonium acetate-acetonitrile (15:85, v/v). The precursor → product ion transitions for nifedipine (m/z 347.2 → 315.2) and IS (m/z 353.1 → 318.1) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive-ion mode. The method was validated over a wide dynamic concentration range of 0.050-150 ng/mL. Matrix effect was assessed by post-column analyte infusion and the mean extraction recovery was 95.6% across four quality control levels. The method is rugged and rapid with a total run time of 1.2 min and was applied to a bioequivalence study of 20 mg nifedipine tablet formulation in 30 healthy Indian subjects under fasting condition. Assay reproducibility was confirmed by reanalysis of 116 incurred samples.

  9. Ultra-performance liquid chromatography tandem mass spectrometry method for the determination of AZ66, a sigma receptor ligand, in rat plasma and its application to in vivo pharmacokinetics.

    Science.gov (United States)

    Jamalapuram, Seshulatha; Vuppala, Pradeep Kumar; Abdelazeem, Ahmed H; McCurdy, Christopher R; Avery, Bonnie A

    2013-08-01

    Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3-[4-(4-cyclohexylpiperazine-1-yl)pentyl]-6-fluorobenzo[d]thiazole-2(3H)-one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid-liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple-quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1-3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague-Dawley rats.

  10. A rapid method for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet by ultra performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan

    2013-05-01

    In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) acid and acetylsalicylic acid in aspirin C effervescent tablet.

  11. Accretion disks around a mass with quadrupole

    CERN Document Server

    Abishev, Medeu; Quevedo, Hernando; Toktarbay, Saken

    2015-01-01

    We consider the stability properties of test particles moving along circular orbits around a mass with quadrupole. We show that the quadrupole modifies drastically the properties of an accretion disk made of such test particles.

  12. Accretion disks around a mass with quadrupole

    Science.gov (United States)

    Abishev, M.; Boshkayev, K.; Quevedo, H.; Toktarbay, S.

    We consider the stability properties of circular orbits of test particles moving around a mass with quadrupole. We show that the quadrupole modifies drastically the properties of an accretion disk made of such test particles.

  13. Determination of secondary and tertiary amines as N-nitrosamine precursors in drinking water system using ultra-fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wu, Qihua; Shi, Honglan; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Timmons, Terry; Jiang, Hua

    2015-01-01

    N-Nitrosamines are potent mutagenic and carcinogenic emerging water disinfection by-products (DBPs). The most effective strategy to control the formation of these DBPs is minimizing their precursors from source water. Secondary and tertiary amines are dominating precursors of N-nitrosamines formation during drinking water disinfection process. Therefore, the screening and removal of these amines in source water are very essential for preventing the formation of N-nitrosamines. A rapid, simple, and sensitive ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed in this study to determine seven amines, including dimethylamine, ethylmethylamine, diethylamine, dipropylamine, trimethylamine, 3-(dimethylaminomethyl)indole, and 4-dimethylaminoantipyrine, as major precursors of N-nitrosamines in drinking water system. No sample preparation process is needed except a simple filtration. Separation and detection can be achieved in 11 min per sample. The method detection limits of selected amines are ranging from 0.02 μg/L to 1 μg/L except EMA (5 μg/L), and good calibration linearity was achieved. The developed method was applied to determine the selected precursors in source water and drinking water samples collected from Midwest area of the United States. In most of water samples, the concentrations of selected precursors of N-nitrosamines were below their method detection limits. Dimethylamine was detected in some of water samples at the concentration up to 25.4 μg/L. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi

    2016-02-01

    A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples.

  15. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  16. Quantification of Oxidized and Unsaturated Bile Alcohols in Sea Lamprey Tissues by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ke Li

    2016-08-01

    Full Text Available A sensitive and reliable method was developed and validated for the determination of unsaturated bile alcohols in sea lamprey tissues using liquid-liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. The liver, kidney, and intestine samples were extracted with acetonitrile and defatted by n-hexane. Gradient UHPLC separation was performed using an Acquity BEH C18 column with a mobile phase of water and methanol containing 20 mM triethylamine. Multiple reaction monitoring modes of precursor-product ion transitions for each analyte was used. This method displayed good linearity, with correlation coefficients greater than 0.99, and was validated. Precision and accuracy (RSD % were in the range of 0.31%–5.28%, while mean recoveries were between 84.3%–96.3%. With this technique, sea lamprey tissue samples were analyzed for unsaturated bile alcohol analytes. This method is practical and particularly suitable for widespread putative pheromone residue analysis.

  17. Assessment of parabens and ultraviolet filters in human placenta tissue by ultrasound-assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Vela-Soria, F; Gallardo-Torres, M E; Ballesteros, O; Díaz, C; Pérez, J; Navalón, A; Fernández, M F; Olea, N

    2017-03-03

    Increasing concerns have been raised over recent decades about human exposure to Endocrine Disrupting Chemicals (EDCs), especially about their possible effects on embryo, foetus, newborn, and child. Parabens (PBs) and ultraviolet filters (UV-filters) are prevalent EDCs widely used as additives in cosmetics and personal care products (PCPs). The objective of this study was to determine the presence of four PBs and ten UV-filters in placental tissue samples using a novel analytical method based on ultrasound-assisted extraction (UAE) and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Multivariate optimization strategies were used to accurately optimize extraction and clean-up parameters. Limits of quantification ranged from 0.15 to 0.5μgkg(-1), and inter-day variability (evaluated as relative standard deviation) ranged from 3.6% to 14%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery percents ranged from 94.5% to 112%. The method was satisfactorily applied for the determination of the target compounds in human placental tissue samples collected at delivery from 15 randomly selected women. This new analytical procedure can provide information on foetal exposure to compounds, which has been little studied.

  18. A column-switching liquid chromatography-tandem mass spectrometry method for quantitation of 2-cyanoethylmercapturic acid and 2-hydroxyethylmercapturic acid in Chinese smokers.

    Science.gov (United States)

    Hou, Hongwei; Xiong, Wei; Gao, Na; Zhang, Xiaotao; Tang, Gangling; Hu, Qingyuan

    2012-11-01

    The acrylonitrile metabolites 2-cyanoethylmercapturic acid (CEMA) and 2-hydroxyethylmercapturic acid (HEMA) have been determined in human urine using an automated column-switching procedure. A diluted sample was centrifuged just prior to being injected into a reusable precolumn packed with a restricted access material and coupled to a liquid chromatography-tandem mass spectrometry system. This method achieved satisfactory reproducibility and accuracy. Average intra- and interday variations (% relative standard deviations) ranged from 2.4 to 3.8% for CEMA and from 2.7 to 10.5% for HEMA. The limits of quantification were 0.003 and 0.099ng/ml for CEMA and HEMA, respectively. It was used to study the uptake of acrylonitrile from smoke constituents by both nonsmokers and smokers of different tar yield cigarettes under ISO 3308 smoking condition. Metabolite concentrations in smoker urine samples were approximately 12 times higher compared with those in nonsmokers for CEMA and 3 times higher for HEMA. Urinary CEMA levels show a clear dose-response relationship with daily cigarette consumption and urinary cotinine. CEMA can also discriminate between smokers of different ISO cigarettes. Because HEMA is not specific, it is only slightly related to smoking and acrylonitrile exposure. The validated biomarker CEMA will continue to be useful for studies of acrylonitrile uptake by smokers.

  19. Automated Analysis of Oxytocin by On-Line in-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Eri Moriyama

    2015-06-01

    Full Text Available A simple and sensitive method for the analysis of oxytocin was developed using automated on-line in-tube solid-phase microextraction (SPME coupled with liquid chromatography-tandem mass spectrometry (LC–MS/MS. Oxytocin was separated within 3 min on a Zorbax Eclipse XDB-C8 column, with water/methanol (10/90, v/v as the mobile phase at a flow rate of 0.2 mL min−1. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection by multiple reaction monitoring. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 µL sample at a flow rate of 250 µL min−1 using a Supel-Q PLOT capillary column as an extraction device. The extracted oxytocin was easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The calibration curves for oxytocin were linear (r = 0.9981 in the range of 0−5.0 ng mL−1, and the relative standard deviations at each point were below 14.7% (n = 3. The limit of detection of this method was 4.0 pg mL−1, and its sensitivity was 58-fold higher than that of the direct injection method. This method was applied successfully to the analysis of oxytocin in saliva samples without any other interference peaks.

  20. Sensitive Monitoring of Fluoroquinolones in Milk and Honey Using Multiple Monolithic Fiber Solid-Phase Microextraction Coupled to Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Lei; Huang, Xiaojia

    2016-11-16

    In the present study, a new multiple monolithic fiber solid-phase microextraction (MMF-SPME) based on poly(apronal-co-divinylbenzene/ethylenedimethacrylate) monolith (APDE) was synthesized. The effect of the preparation parameters of APED on extraction efficiency was studied thoroughly. The combination of APDE/MMF-SPME with high-performance liquid chromatography tandem mass spectrometry detection (HPLC/MS-MS) was developed for sensitive monitoring of ultratrace fluoroquinolones (FQs) in foodstuffs, including milk and honey samples. Under the optimized experimental conditions, the limits of detection (S/N = 3) for the targeted FQs ranged from 0.0019 to 0.018 μg/kg in milk and 0.0010 to 0.0028 μg/kg in honey. The relative standard deviations (RSDs) for method reproducibility were less than 9% in all samples. The established method was successfully applied for the monitoring of FQs residues in milk and honey samples with the recoveries between 74.5% and 116% (RSDs were in the range 0.9-9.5%). In comparison to previous methods, the developed APDE/MMF-SPME-HPLC/MS-MS showed some merits, including satisfactory sensitivity, simplicity, high cost-effectiveness, and low consumption of organic solvent.

  1. Blood monitoring of perfluorocarbon compounds (F-tert-butylcyclohexane, perfluoromethyldecalin and perfluorodecalin) by headspace-gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Giuliani, N; Saugy, M; Augsburger, M; Varlet, V

    2015-11-01

    A headspace-gas chromatography-tandem mass spectrometry (HS-GC-MS/MS) method for the trace measurement of perfluorocarbon compounds (PFCs) in blood was developed. Due to oxygen carrying capabilities of PFCs, application to doping and sports misuse is speculated. This study was therefore extended to perform validation methods for F-tert-butylcyclohexane (Oxycyte(®)), perfluoro(methyldecalin) (PFMD) and perfluorodecalin (PFD). The limit of detection of these compounds was established and found to be 1.2 µg/mL blood for F-tert-butylcyclohexane, 4.9 µg/mL blood for PFMD and 9.6 µg/mL blood for PFD. The limit of quantification was assumed to be 12 µg/mL blood (F-tert-butylcyclohexane), 48 µg/mL blood (PFMD) and 96 µg/mL blood (PFD). HS-GC-MS/MS technique allows detection from 1000 to 10,000 times lower than the estimated required dose to ensure a biological effect for the investigated PFCs. Thus, this technique could be used to identify a PFC misuse several hours, maybe days, after the injection or the sporting event. Clinical trials with those compounds are still required to evaluate the validation parameters with the calculated estimations.

  2. High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki

    2016-11-01

    A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na2 PO4 H2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r(2) = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.

  3. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Quantitation of Microcystins in Blue-Green Algal Dietary Supplements.

    Science.gov (United States)

    Parker, Christine H; Stutts, Whitney L; DeGrasse, Stacey L

    2015-12-02

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous detection and quantitation of seven microcystin congeners (1-7) and nodularin-R (8) in blue-green algal dietary supplements. Single-laboratory method validation data were collected in four supplement matrices (capsule, liquid, powder, and tablet) fortified at toxin concentrations from 0.25-2.00 μg/g (ppm). Average recoveries and relative standard deviations (RSD) using matrix-corrected solvent calibration curves were 101% (6% RSD) for all congeners and supplements investigated. Limits of detection (0.006-0.028 μg/g) and quantitation (0.018-0.084 μg/g) were sufficient to confirm the presence of microcystin contamination at the Oregon-mandated guidance concentration of 1.0 μg of microcystin-LReq/g. Quantitated concentrations of microcystin contamination in market-available Aphanizomenon flos-aquae blue-green algal supplements ranged from 0.18-1.87 μg of microcystin-LReq/g for detected congeners microcystin-LR, microcystin-LA, and microcystin-LY (3-5). Microcystin-RR, -YR, -LW, and -LF and nodularin-R (1, 2, and 6-8) were not detected in the supplements examined.

  4. Analysis of 76 veterinary pharmaceuticals from 13 classes including aminoglycosides in bovine muscle by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Dasenaki, Marilena E; Michali, Christina S; Thomaidis, Nikolaos S

    2016-06-24

    A multiresidue/multiclass method for the simultaneous determination of 76 veterinary drugs and pharmaceuticals in bovine muscle tissue has been developed and validated according to the requirements of European Commission Decision 2002/657/EC. The analytes belong in 13 different classes, including aminoglycoside antibiotics, whose different physicochemical properties (extremely polar character) render their simultaneous determination with other veterinary drugs quite problematic. The method combines a two-step extraction procedure (extraction with acetonitrile followed by an acidic aqueous buffer extraction) with hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) determination, allowing confirmation and quantification in a single chromatographic run. Further cleanup with solid phase extraction was performed using polymeric SPE cartridges. A thorough ionization study of aminoglycosides was performed in order to increase their sensitivity and significant differences in the abundance of the precursor ions of the analytes were revealed, depending on the composition of the mobile phase tested. Further gradient elution optimization and injection solvent optimization were performed for all target analytes.The method was validated according to the European Commission Decision 2002/657. Quantitative analysis was performed by means of standard addition calibration. Recoveries varied from 37.4% (bromhexine) to 106% (kanamycin) in the lowest validation level and 82% of the compounds showed recovery >70%. Detection capability (CCβ) varied from 2.4 (salinomycin) to 1302 (apramycin) μgkg(-1).

  5. Simultaneous determination of β-lactam antibiotics and β-lactamase inhibitors in bovine milk by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Nasi; Feng, Feng; Yang, Bingcheng; Jiang, Pingping; Chu, Xiaogang

    2014-01-15

    An ultra performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method has been developed for the simultaneous determination of four β-lactam antibiotics (amoxicillin, ampicillin, cefotaxime, and cefoperazone) and two β-lactamase inhibitors (tazobactam, sulbactam) in bovine milk. The analytes were extracted with water from bovine milk and purified with Oasis HLB solid phase extraction (SPE) cartridges. The analytes were determined in less than 3min by UPLC-MS/MS in positive and negative electrospray ionization (ESI) modes, separately. The method was linear over the range of 1-100μg/L for tazobactam, sulbactam, ampicillin, and cefoperazone, and 2-100μg/L for amoxicillin and cefotaxime. The recoveries for all six analytes in bovine milk ranged from 82.5 to 98.3%. The limits of detection and the limits of quantitation were 0.1-0.2μg/L and 0.3-0.5μg/L, respectively. The intra- and inter-day precisions were less than 6% for each compound.

  6. Determination of ceftiofur metabolite desfuroylceftiofur cysteine disulfide in bovine tissues using liquid chromatography-tandem mass spectrometry as a surrogate marker residue for ceftiofur.

    Science.gov (United States)

    Feng, Shixia; Chiesa, Oscar A; Kijak, Philip; Chattopadhaya, Chaitali; Lancaster, Vicki; Smith, Elizabeth A; Girard, Lauren; Sklenka, Sara; Li, Hui

    2014-06-04

    Ceftiofur is a widely used cephalosporin β-lactam antibiotic with frequently reported residue violations. This paper reports a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining a ceftiofur metabolite, desfuroylceftiofur cysteine disulfide (DCCD), in bovine kidney, liver, and muscle tissues. Incurred tissue samples were obtained from dosed animals and analyzed to evaluate the utility of the method. For kidney, the target tissue, the method utilized a simple extraction with phosphate buffer followed by solid phase extraction (SPE) cleanup. For liver and muscle, acetonitrile and hexane were used to remove most proteins and fat from the initial buffer extract before the SPE cleanup. Method accuracy was between 97 and 107%, and the coefficient of variation was between 3.4 and 11.0% for all three types of tissues. The relationship between the new and regulatory methods for bovine kidney was established. It was concluded that DCCD is a suitable surrogate marker residue for ceftiofur in bovine kidney.

  7. Biomonitoring of 21 endocrine disrupting chemicals in human hair samples using ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Gómez, R; Martín, J; Zafra-Gómez, A; Alonso, E; Vílchez, J L; Navalón, A

    2017-02-01

    Rapid industrial growth has increased human exposure to a large variety of chemicals with adverse health effects. These industrial chemicals are usually present in the environment, foods, beverages, clothes and personal care products. Among these compounds, endocrine disrupting chemicals (EDCs) have raised concern over the last years. In the present work, the determination of 21 EDCs in human hair samples is proposed. An analytical method based on the digestion of the samples with a mixture of acetic acid/methanol (20:80, v/v) followed by a solid-liquid microextraction and analysis by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and validated. The most influential parameters affecting the extraction method were optimized. The method was validated using matrix-matched calibration and recovery assays. Limits of detection ranged from 0.2 to 4 ng g(-1), limits of quantification from 0.5 to 12 ng g(-1), and inter- and intra-day variability was under 15% in all cases. Recovery rates for spiked samples ranged from 92.1 to 113.8%. The method was applied for the determination of the selected compounds in human hair. Samples were collected weekly from six randomly selected volunteers (three men and three women) over a three-month period. All the analyzed samples tested positive for at least one of the analyzed compounds.

  8. Determination of Earthy-musty Odorous Compounds in Drinking Water by Vortex Assisted Dispersive Liquid-Liquid Microextraction Combined with Gas Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Lu, Jian; Wu, Zhong-Ping; Che, Wen-Jun; Xian, Yan-Ping; Guo, Xin-Dong; Lv, Jia-Xin; Li, He

    2016-01-01

    A new method was developed for the determination of eight earthy-musty compounds in drinking water by gas chromatography tandem mass spectrometry (GC-MS/MS) combined with dispersive liquid-liquid microextraction (DLLME). In this work, the type and volume of extraction solvent and dispersion agent, and the amount of NaCl were optimized; the linearity, detection limit, recovery and precision of method were investigated. The results indicated that the target analytes were in the range of 0.2 - 100 μg/L with correlation coefficient (r) ranging from 0.9991 to 0.9999, the limit of detection (LOD, S/N = 3) of the analytes ranged from 0.2 to 1.0 ng/L with the enrichment factor of 320. The mean recoveries for drinking water at three spiked concentrations levels of 0.6 - 32 ng/L were in the range of 91.3 to 103%, the precision ranged from 3.1 to 7.5% (n = 6), and the inter-day precision was from 6.1 to 11.1% (n = 5). Only one of 15 selected real samples tested positive for GSM, and the concentration was 3 ng/L. This method was confirmed to be simple, fast, efficient, and accurate for the determination of earthy-musty compounds in aqueous samples.

  9. Human liver cytosolic sulfotransferase 2A1-dependent dehydroepiandrosterone sulfation assay by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Bansal, Sumit; Lau, Aik Jiang

    2016-02-20

    Sulfotransferase 2A1 (SULT2A1) is a major catalyst of the sulfation of dehydroepiandrosterone (DHEA) to dehydroepiandrosterone sulfate (DHEA-S) in human liver cytosol. However, there is a lack of a sensitive and fast analytical method for the human liver cytosolic SULT2A1-dependent DHEA sulfation assay. Therefore, we developed and validated an ultra-high performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method to quantify DHEA-S and used it to optimize the human liver cytosolic SULT2A1-dependent DHEA sulfation assay. DHEA-S and cortisol (internal standard) eluted at 2.95 and 2.75min, respectively. Negative multiple reaction monitoring was used to quantify DHEA-S (m/z 367.3→97.0) and cortisol (m/z 407.2→331.3). No interfering peaks were observed in blank samples. The lower limit of quantification was 0.2pmol DHEA-S and the calibration curve was linear from 0.2 to 200pmol. The intra-day and inter-day accuracy and precision was sulfotransferase enzyme assays, and it is the first UPLC-MS/MS method for determining SULT2A1-dependent DHEA sulfation in human liver cytosol.

  10. Optimization of Sample Preparation for the Identification and Quantification of Saxitoxin in Proficiency Test Mussel Sample using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available Saxitoxin (STX and some selected paralytic shellfish poisoning (PSP analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS. Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk. Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD.

  11. Evaluation of treadmill exercise effect on muscular lipid profiles of diabetic fatty rats by nanoflow liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Lee, Jong Cheol; Kim, Il Yong; Son, Yeri; Byeon, Seul Kee; Yoon, Dong Hyun; Son, Jun Seok; Song, Han Sol; Song, Wook; Seong, Je Kyung; Moon, Myeong Hee

    2016-07-01

    We compare comprehensive quantitative profiling of lipids at the molecular level from skeletal muscle tissues (gastrocnemius and soleus) of Zucker diabetic fatty rats and Zucker lean control rats during treadmill exercise by nanoflow liquid chromatography-tandem mass spectrometry. Because type II diabetes is caused by decreased insulin sensitivity due to excess lipids accumulated in skeletal muscle tissue, lipidomic analysis of muscle tissues under treadmill exercise can help unveil the mechanism of lipid-associated insulin resistance. In total, 314 lipid species, including phospholipids, sphingolipids, ceramides, diacylglycerols (DAGs), and triacylglycerols (TAGs), were analyzed to examine diabetes-related lipid species and responses to treadmill exercise. Most lysophospholipid levels increased with diabetes. While DAG levels (10 from the gastrocnemius and 13 from the soleus) were >3-fold higher in diabetic rats, levels of most of these decreased after exercise in soleus but not in gastrocnemius. Levels of 5 highly abundant TAGs (52:1 and 54:3 in the gastrocnemius and 48:2, 50:2, and 52:4 in the soleus) displaying 2-fold increases in diabetic rats decreased after exercise in the soleus but not in the gastrocnemius in most cases. Thus, aerobic exercise has a stronger influence on lipid levels in the soleus than in the gastrocnemius in type 2 diabetic rats.

  12. Simultaneous high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) analysis of cyanide and thiocyanate from swine plasma.

    Science.gov (United States)

    Bhandari, Raj K; Manandhar, Erica; Oda, Robert P; Rockwood, Gary A; Logue, Brian A

    2014-01-01

    An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na(13)C(15)N and NaS(13)C(15)N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1-50 and 0.2-50 μM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.

  13. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Ruiyue Yang

    Full Text Available BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. RESULTS: Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. CONCLUSION: A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  14. Investigation of endogenous blood lipids components that contribute to matrix effects in dried blood spot samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ismaiel, Omnia A; Jenkins, Rand G; Karnes, H Thomas

    2013-08-01

    Dried blood spot (DBS) sampling coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a rapidly developing approach in the field of biopharmaceutical analysis. DBS sampling enables analysis of small sample volumes with high sensitivity and selectivity while providing a convenient easy to store and ship format. Lipid components that may be extracted during biological sample processing may result in matrix ionization effects and can significantly affect the precision and accuracy of the results. Glycerophosphocholines (GPChos), cholesterols and triacylglycerols (TAG) are the main lipid components that contribute to matrix effects in LC-MS/MS. Various organic solvents such as methanol, acetonitrile, methyl tertiary butyl ether, ethyl ether, dichloromethane and n-hexane were investigated for elution of these lipid components from DBS samples. Methanol extracts demonstrated the highest levels of GPChos whereas ethyl ether and n-hexane extracts contained less than 1.0 % of the GPChos levels in the methanol extracts. Ethyl ether extracts contained the highest levels of cholesterols and TAG in comparison to other investigated organic solvents. Acetonitrile is recommended as an elution solvent due to low lipid recoveries. Matrix effects resulted from different extracted lipid components should be studied and assessed carefully in DBS samples.

  15. Determination of Geochemically Important Sterols and Triterpenols in Sediments Using Ultrahigh-Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS).

    Science.gov (United States)

    Bataglion, Giovana Anceski; Meurer, Eduardo; de Albergaria-Barbosa, Ana Cecília Rizzatti; Bícego, Márcia Caruso; Weber, Rolf Roland; Eberlin, Marcos Nogueira

    2015-08-04

    A fast, sensitive, and selective ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method that is able to quantify geochemical biomarkers in sediment is described. A pool of 10 sterols, which can be used as biomarkers of autochthonous (cholesterol, cholestanol, brassicasterol, ergosterol), allochthonous (stigmasterol, β-sitosterol, campesterol, and stigmastanol) and anthropogenic (coprostanol and epicoprostanol) organic matter (OM), and three triterpenols (lupeol, α-amyrin, and β-amyrin) were chosen as the analytes. The method showed excellent analytical parameters, and, compared with the traditional GC-MS methods that are commonly applied for the analysis of sterols, this method requires no sample cleanup or derivatization and presents improved values for the LOD and LOQ. UHPLC can separate the diastereoisomers (epicoprostanol, coprostanol, and cholestanol) and the isomers (lupeol, α-amyrin, and β-amyrin). The method was successfully applied for the quantification of the biomarkers, and thus, it was applied to assess the OM sources and the impacts of anthropogenic activities in sediments from different environments, such as Antarctica and other Brazilian systems (Continental Shelf, São Sebastião Channel, and Santos Estuary). Unique profiles of the biomarkers were observed for the contrasting environments, and β-amyrin and cholesterol were more predominant in the Santos Estuary and Antarctica samples, respectively. The sterol ratios indicated a higher level of sewage contamination in the Santos Estuary.

  16. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol in foods.

    Science.gov (United States)

    Milder, Ivon E J; Arts, Ilja C W; Venema, Dini P; Lasaroms, Johan J P; Wähälä, Kristina; Hollman, Peter C H

    2004-07-28

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymatic hydrolysis using Helix pomatia (H. pomatia) beta-glucuronidase/sulfatase. H. pomatia was selected from several enzymes based on its ability to hydrolyze isolated lignan glucosides. After ether extraction samples were analyzed and quantified against secoisolariciresinol-d8 and matairesinol-d6. The method was optimized using model products: broccoli, bread, flaxseed, and tea. The yield of methanolic extraction increased up to 81%, when it was combined with alkaline hydrolysis. Detection limits were 4-10 microg/(100 g dry weight) for solid foods and 0.2-0.4 microg/(100 mL) for beverages. Within- and between-run coefficients of variation were 6-21 and 6-33%, respectively. Recovery of lignans added to model products was satisfactory (73-123%), except for matairesinol added to bread (51-55%).

  17. Simultaneous determination of four aflatoxins and ochratoxin A in ginger after inoculation with fungi by ultra-fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yang, Ying; Wen, Jing; Kong, Weijun; Liu, Qiutao; Luo, Hongli; Wang, Jian; Yang, Meihua

    2016-09-01

    Aflatoxins (AFs) and ochratoxin A (OTA) have been detected frequently in food, agricultural products and traditional Chinese medicines, and their presence poses serious health and economic problems worldwide. Ginger can easily be polluted with mycotoxins. In this study, ginger samples were cultivated for 15 days after inoculation with fungi and were prepared based on ultrasound-assisted solid-liquid extraction using methanol/water followed by immunoaffinity column clean-up and analysed by ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) for AFs and OTA. The limits of detection and quantification of AFs and OTA were 0.04-0.30 µg mL(-1) and 0.125-1.0 µg mL(-1) , respectively. The recoveries were 82.0-100.2%. After 15 days' cultivation, no macroscopic mildew was found in ginger. But, the content of AFB1 expressed an increasing trend in ginger, peel [less than the limit of quantification (LOQ)] to the innermost layer (51.86 µ mL(-1) ), AFB2 was only detected in the innermost layer at the level of 0.87 µ mL(-1) . A small amount (safety and quality of ginger. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  18. Absolute quantification of Pru av 2 in sweet cherry fruit by liquid chromatography/tandem mass spectrometry with the use of a stable isotope-labelled peptide.

    Science.gov (United States)

    Ippoushi, Katsunari; Sasanuma, Motoe; Oike, Hideaki; Kobori, Masuko; Maeda-Yamamoto, Mari

    2016-08-01

    Pru av 2, a pathogenesis-related (PR) protein present in the sweet cherry (Prunus avium L.) fruit, is the principal allergen of cherry and one of the chief causes of pollen food syndrome (oral allergy syndrome). In this study, a quantitative assay for this protein was developed with the use of the protein absolute quantification (AQUA) method, which consists of liquid chromatography/tandem mass spectrometry (LC/MS/MS) employing TGC[CAM]STDASGK[(13)C6,(15)N2], a stable isotope-labelled internal standard (SIIS) peptide. This assay gave a linear relationship (r(2)>0.99) in a concentration range (2.3-600fmol/μL), and the overall coefficient of variation (CV) for multiple tests was 14.6%. Thus, the contents of this allergenic protein in sweet cherry products could be determined using this assay. This assay should be valuable for allergological investigations of Pru av 2 in sweet cherry and detection of protein contamination in foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. [Determination of gibberellins in Arabidopsis thaliana by matrix solid-phase dispersion extraction and high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wang, Lu; Wu, Qian; Duan, Chunfeng; Wu, Dapeng; Guan, Yafeng

    2011-09-01

    A method for the analysis of gibberellin A1 (GA1), gibberellin A3 (GA3) and gibberellin A4 (GA4) in Arabidopsis thaliana by matrix solid-phase dispersion extraction (MSPD) and high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The solid sample of Arabidopsis thaliana was gently blended with C18 to obtain a homogeneous mixture. This mixture was transferred to an SPE cartridge filled with 0.5 g C18 to form a MSPD column. GA1, GA3 and GA4 were eluted with cold 80% methanol aqueous solution. The target compounds were separated on a C18 column with a gradient elution of 0.05% formic acid aqueous solution and acetonitrile as the mobile phase. The identification and quantification were carried out by using electrospray ionization in negative ion mode (ESI-) with multiple reaction monitoring (MRM). The linear ranges for GA1, GA3 and GA4 were all from 10 to 300 ng/g with correlation coefficients greater than 0.98. The limits of detection were in the range of 1.1-4.1 ng/g. The average recoveries and relative standard deviations were 54.7%-102.6% and 3.2%-12.8% respectively in the spiked range of 10-50 ng/g. The method is simple, sensitive, efficient and accurate. It is suitable for the confirmation and quantitative determination of GA1, GA3 and GA4 in Arabidopsis thaliana.

  20. Molecularly imprinted polymer-sol-gel tablet toward micro-solid phase extraction: I. Determination of methadone in human plasma utilizing liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    El-Beqqali, Aziza; Abdel-Rehim, Mohamed

    2016-09-14

    In the present work molecularly imprinted sol-gel tablet (MIP-Tablet) was prepared. The MIP-sol-gel was prepared as a thin layer on polyethylene material in a tablet form. Methadone-d9 was selected as the template and 3-(propylmethacrylate)-trimethoxysilane was used as precursor. MIP-Tablet was applied for micro-solid phase extraction (μ-SPE). The MIP-Tablet was used for the determination of methadone in human plasma samples utilizing liquid chromatography-tandem mass spectrometry; and each tablet could be used twenty times. The extraction time was 10 min while desorption time was 6 min. Factors affecting the extraction efficiency such as desorption solvents, sample pH, salt addition, extraction time, desorption time and adsorption capacity were investigated. The calibration curves were obtained within the range of 5-5000 ng/mL using methadone in human plasma samples. The coefficients of determination (r(2)) values were ≥0.999 for all runs and the extraction recovery was >80%. The accuracy values for quality control samples varied from +3.6 to +9.7% and the inter-day precision (RSD %) values were ranged from 5.0 to 8.0%. The limit of detection was 1.0 ng/mL and the lower limit of quantification was 5 ng/mL utilizing methadone in human plasma samples.

  1. Rapid determination of 12 antibiotics and caffeine in sewage and bioreactor effluent by online column-switching liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Lima Gomes, Paulo C F; Tomita, Inês N; Santos-Neto, Álvaro J; Zaiat, Marcelo

    2015-11-01

    This study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed. The method was tested in terms of detection (MDL) and quantification limit (MQL), linearity, relative recovery, and precision intra- and inter-day in lab-made sewage samples. The method presented suitable figures of merit in terms of detection, varying from 8.00 × 10(-5) to 6.00 × 10(-2) ng (0.800 up to 600 ng L(-1); caffeine) with direct injection volume of only 100 μL and 13 min of total analysis time (sample preparation and chromatographic run). When the method was applied in the analysis of sewage and effluent of the anaerobic reactor (n = 15), six antibiotics and caffeine were detected in concentrations ranging from 0.018 to 1097 μg L(-1). To guarantee a reliable quantification, standard addition was used to overcome the matrix effect.

  2. Simultaneous determination of some phthalate metabolites, parabens and benzophenone-3 in urine by ultra high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dewalque, Lucas; Pirard, Catherine; Dubois, Nathalie; Charlier, Corinne

    2014-02-15

    Phthalates, parabens and 2-hydroxy-4-methoxybenzophenone or benzophone-3 are thought to act as endocrine disrupting chemicals, being able to disrupt the endocrine balance and therefore able to lead to some hormonal diseases. Numerous large-scale biomonitoring studies have detected the biomarkers of these compounds in more than 75% of the general population. To assess the exposure to these chemicals, we developed an analytical method based on a Solid Phase Extraction (SPE) prior to ultra high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the simultaneous measurement of seven phthalate metabolites (monobenzyl phthalate, mono-n-butyl phthalate, mono-iso-butyl phthalate, mono-2-ethylhexyl phthalate, mono-2-ethyl-5-hydroxyhexyl phthalate, mono-2-ethyl-5-oxohexyl phthalate, monoethyl phthalate), four parabens (methyl paraben, ethyl paraben, n-propyl paraben, n-butyl parabens) and benzophenone-3 in human urine. The distinction between unconjugated, glucuro- and sulfoconjugated forms was achieved using different enzymatic hydrolyses. The whole procedure was validated according to the total error approach, and was demonstrated to be linear (regression coefficient ranging from 0.987 to 0.998) and accurate (inter and intra assay precision parabens and benzophenone-3 were positively detected in almost all urine samples, with detection rates ranging from 40 to 100%. Levels measured ranged from parabens and benzophenone-3 were detected as glucuro- and sulfoconjugated species in variable proportions according to the target compound. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. [Determination of virginiamycin M1 and S1 residues in livestock and poultry products by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Qiu, Yuanjin; Yang, Fang; Liu, Zhengcai; Lin, Yonghui; Liu, Suzhen

    2012-05-01

    A liquid chromatography-tandem mass spectrometry method was established for the determination of virginiamycin M1 and S1 residues in livestock and poultry products. The sample was extracted by methanol-acetonitrile solution (1:1, v/v). The supernatant was diluted with 0.01 mol/L ammonium dihydrogen phosphate solution, then purified and concentrated on an Oasis HLB cartridge. The separation of virginiamycin M1 and S1 was performed on a Luna C18 column with the mobile phases acetonitrile and 5 mmol/L ammonium acetate aqueous solution (containing 0.1% (v/v) formic acid) in a gradient elution mode. The identification and quantification of the drugs were carried out by positive electrospray ionization (ESI + ) in the multiple reaction monitoring (MRM) mode using external standard method. The calibration curves showed good linearity in the range of 0.15-10.0 microg/L with correlation coefficients (r2) above 0. 999. The limits of quantities (LOQs) were both 0.25 microg/kg. The average recoveries of the two drugs spiked at 0.25, 0.5 and 2.5 microg/kg levels in different matrices were between 71.2% and 98.4%, and the relative standard deviations (RSDs) were between 3.6% and 15.4%. The method is simple, rapid, sensitive and accurate. It is suitable for the confirmation and quantification of virginiamycin M1 and S1 residues in livestock and poultry products.

  4. Ultra-trace level speciated isotope dilution measurement of Cr(VI) using ion chromatography tandem mass spectrometry in environmental waters.

    Science.gov (United States)

    Mädler, Stefanie; Todd, Aaron; Skip Kingston, H M; Pamuku, Matt; Sun, Fengrong; Tat, Cindy; Tooley, Robert J; Switzer, Teresa A; Furdui, Vasile I

    2016-08-15

    The reliable analysis of highly toxic hexavalent chromium, Cr(VI), at ultra-trace levels remains challenging, given its easy conversion to non-toxic trivalent chromium. This work demonstrates a novel analytical method to quantify Cr(VI) at low ngL(-1) concentration levels in environmental water samples by using speciated isotope dilution (SID) analysis and double-spiking with Cr(III) and Cr(VI) enriched for different isotopes. Ion chromatography tandem mass spectrometry (IC-MS/MS) was used for the analysis of Cr(VI) as HCrO4(-) → CrO3(-). Whereas the classical linear multipoint calibration (MPC) curve approach obtained a method detection limit (MDL) of 7ngL(-1) Cr(VI), the modified SID-MS method adapted from U. S. EPA 6800 allowed for the quantification of Cr(VI) with an MDL of 2ngL(-1) and provided results corrected for Cr(VI) loss occurred after sample collection. The adapted SID-MS approach proved to yield more accurate and precise results than the MPC method, allowed for compensation of Cr(VI) reduction during sample transportation and storage while eliminating the need for frequent external calibration. The developed method is a complementary tool to routinely used inductively-coupled plasma (ICP) MS and circumvents typically experienced interferences.

  5. A new method for rapid and quantitative detection of the Bacillus cereus emetic toxin cereulide in food products by liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Yamaguchi, Mizuka; Kawai, Takao; Kitagawa, Mikiya; Kumeda, Yuko

    2013-05-01

    The Bacillus cereus emetic toxin cereulide causes foodborne intoxication, which may occasionally result in severe disease, and even death. To differentially diagnose the emetic-type of foodborne disease caused by B. cereus and assess the safety of commercial food, we developed a rapid method to quantitate cereulide. This method was combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis for the extraction of cereulide from food using a normal-phase silica gel cartridge. The limits of detection and quantification were 0.1 and 0.5 ng of cereulide ml(-1), respectively. Spiked cereulide was reproducibly recovered with over 67% efficiency from nine diverse foods implicated in cereulide food poisoning. The recovery rate, reproducibility, and intermediate precision for this single laboratory validation using boiled rice were 87.1%, 4.4%, and 7.0%, respectively. Further, we detected a wide range of cereulide concentrations in leftover food and vomitus samples from two emetic foodborne outbreaks. LC-MS/MS analysis correlated closely with those acquired using the HEp-2 cell assay, and quantitated cereulide from 10 food samples at least five times faster than the bioassay. This new method will provide clinicians with an improved tool for more rapidly and quantitatively determining the presence of cereulide in food and diagnosing food poisoning caused by cereulide.

  6. Analysis of Nitrosamines in Cooked Bacon by QuEChERS Sample Preparation and Gas Chromatography-Tandem Mass Spectrometry with Backflushing.

    Science.gov (United States)

    Lehotay, Steven J; Sapozhnikova, Yelena; Han, Lijun; Johnston, John J

    2015-12-02

    Nitrites are added as a preservative to a variety of cured meats, including bacon, to kill bacteria, extend shelf life, and improve quality. During cooking, nitrites in the meat can be converted to carcinogenic nitrosamines (NAs), the formation of which is mitigated by the addition of antioxidants. In the past, the U.S. Department of Agriculture (USDA) Food Safety and Inspection Service (FSIS) monitored NAs in pan-fried bacon, but FSIS terminated monitoring of NAs in the 1990s due to the very low levels found. FSIS recently chose to conduct a risk assessment of NAs in cooked bacon to determine if current levels warrant routine monitoring of NAs again. To meet FSIS needs, we developed, validated, and implemented a new method of sample preparation and analysis to test cooked bacon for five NAs of most concern, which consist of N-nitroso-dimethylamine, -diethylamine, -dibutylamine, -piperidine, and -pyrrolidine. Sample preparation was based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) approach and analysis by gas chromatography-tandem mass spectrometry. Ruggedness was improved markedly in the analysis of the complex fatty extracts by backflushing the guard column, injection liner, and half of the analytical column after every injection. Validation results were acceptable with recoveries of 70-120% and bacon gave slightly lower concentrations overall compared to pan-frying.

  7. Determination and quantification of the emetic toxin cereulide from Bacillus cereus in pasta, rice and cream with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rønning, Helene Thorsen; Asp, Tone Normann; Granum, Per Einar

    2015-01-01

    A rapid and sensitive method has been developed for determination and quantification of cereulide in cream, rice and pasta. Samples are homogenised after addition of amylase to cooked rice and pasta, and cereulide is extracted with methanol. After the removal of water with methyl-tert butyl ether/hexane and evaporation until dryness, no further purification was required before analysis with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Recently, both cereulide and (13)C6-cereulide has become commercially available at high purities; hence, this method offers a more reliable quantification of positive samples than previous methods using valinomycin or in-house produced and purified cereulide as calibration standard. The introduction of amylase in the sample preparation improves both the extraction yield of cereulide from positive samples of starch-rich matrices such as pasta and rice, and the within-laboratory reproducibility of the analytical method. The LoQ of the method is 1.1 ng/g cereulide with RSDs ranging from 2.6% to 10%. The method is fully validated based on Commission Decision 2002/657/EC, suitable for routine analysis, and has been used to analyse samples from a cereulide food poisoning outbreak in a kindergarten in Norway. Cereulide production in different rice and pasta samples was investigated, showing that cereulide was unexpectedly produced by emetic Bacillus cereus in all eight pasta and rice samples.

  8. Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    P Pavan Kumar

    2015-01-01

    Full Text Available A new, simple and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS method for simultaneous determination of rosuvastatin (ROS and metformin (MET in human plasma was developed. The assay procedure involved simple protein precipitation with acetonitrile. Following precipitation, fraction of supernatant was decanted and evaporated under gentle stream of nitrogen at 40΀C. The residue was reconstituted in mobile phase and injected. The chromatographic separation was achieved with Thermo Hypurity C18 column (50 mm Χ 4.6 mm, 5 μ using a mobile phase composition containing 0.1% v/v formic acid in water and acetonitrile (30:70, v/v at a flow rate of 0.4 mL/min. The total run time was 3.5 min. The method showed good linearity in the range 0.5-200 ng/mL for ROS and 2-2000 ng/mL for MET with correlation coefficient (r >0.9994 for both the analytes. The intra and inter-day precision values for ROS and MET met the acceptance criteria as per regulatory guidelines. The battery of stability studies viz., bench-top, freeze-thaw and long term stability were performed. The developed method was applied to a pharmacokinetic study.

  9. Determination of gymnemagenin in rat plasma using high-performance liquid chromatography-tandem mass spectrometry: application to pharmacokinetics after oral administration of Gymnema sylvestre extract.

    Science.gov (United States)

    Kamble, Bhagyashree; Gupta, Ankur; Patil, Dada; Khatal, Laxman; Janrao, Shirish; Moothedath, Ismail; Duraiswamy, Basavan

    2013-05-01

    A sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the determination of gymnemagenin (GMG), a triterpene sapogenin from Gymnema sylvestre, in rat plasma using withaferin A as the internal standard (IS). Plasma samples were simply extracted using liquid-liquid extraction with tetra-butyl methyl ether. Chromatographic separation was performed on Luna C(18) column using gradient elution of water and methanol (with 0.1% formic acid and 0.3% ammonia) at a flow rate of 0.8 mL/min. GMG and IS were eluted at 4.64 and 4.36 min, ionized in negative and positive mode, respectively, and quantitatively estimated using multiple reaction monitoring (MRM) mode. Two MRM transitions were selected at m/z 505.70 → 455.5 and m/z 471.50 → 281.3 for GMG and IS, respectively. The assay was linear over the concentration range of 5.280-300.920 ng/mL. The mean plasma extraction recoveries for GMG and IS were found to be 80.92 ± 8.70 and 55.63 ± 0.76%, respectively. The method was successfully applied for the determination of pharmacokinetic parameters of GMG after oral administration of G. sylvestre extract.

  10. Simultaneous determination of a novel diphenylpiperazine calcium channel blocker and its four metabolites in rat liver microsomes by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Guo, Wei; Kong, Dezhi; Du, Yingfeng; Shi, Xiaowei; Wang, Wei; Wang, Yongli

    2012-01-01

    Dipfluzine hydrochloride (Dip), a novel diphenylpiperazine calcium channel blocker, has revealed the characteristics of a promising candidate for the treatment of cerebral vascular diseases in preclinical studies. Our research identified and quantified Dip and its 4 metabolites (M1, M2, M4 and M5) in rat liver microsomes by liquid chromatography tandem mass spectrometry. The results showed that Dip was firstly metabolized to M1 and M5 by 1- and 4-dealkylation from a piperazine nitrogen, and then the latter was subsequently metabolized to M2 and M4. The concentrations of Dip, M1, M2 and M5 were 557.3 ± 26.3, 854.3 ± 46.0, 2796.7± 126.9, 2473.3 ± 82.6 and 4.0 ± 0.4, 2.4 ± 0.1, 318.2 ± 8.7 and 27.4 ± 1.5 ng/ml in male and female rats, respectively. M4 (404.2 ± 22.2 ng/ml) was detected only in males not in females, suggesting that there is gender difference in the metabolism of Dip.

  11. A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients.

    Science.gov (United States)

    Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako

    2016-08-01

    A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Use of Imipenem To Detect KPC, NDM, OXA, IMP, and VIM Carbapenemase Activity from Gram-Negative Rods in 75 Minutes Using Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Kulkarni, M. V.; Zurita, A. N.; Pyka, J. S.; Murray, T. S.; Hodsdon, M. E.

    2014-01-01

    Resistance to extended-spectrum β-lactam antibiotics has led to a greater reliance upon carbapenems, but the expression of carbapenemases threatens to limit the utility of these drugs. Current methods to detect carbapenemase activity are suboptimal, requiring prolonged incubations during which ineffective therapy may be prescribed. We previously described a sensitive and specific assay for the detection of carbapenemase activity using ertapenem and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this study, we assessed 402 Gram-negative rods, including both Enterobacteriaceae and non-Enterobacteriaceae expressing IMP, VIM, KPC, NDM, and/or OXA carbapenemases, by using imipenem, meropenem, and ertapenem with LC-MS/MS assays. LC-MS/MS methods for the detection of intact and hydrolyzed carbapenems from an enrichment broth were developed. No ion suppression was observed, and the limits of detection for all three drugs were below 0.04 μg/ml. The sensitivity and specificity of meropenem and ertapenem for carbapenemase activity among non-Enterobacteriaceae were low, but imipenem demonstrated a sensitivity and specificity of 96% and 95%, respectively, among all Gram-negative rods (GNR) tested, including both Enterobacteriaceae and non-Enterobacteriaceae. LC-MS/MS allows for the analysis of more complex matrices, and this LC-MS/MS assay could easily be adapted for use with primary specimens requiring growth enrichment. PMID:24789180

  13. Simultaneous determination of thirteen aminoalcohol-diterpenoid alkaloids in the lateral roots of Aconitum carmichaeli by solid-phase extraction-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ding, Jia-Yu; Liu, Xiu-Xiu; Xiong, Dong-Mei; Ye, Li-Ming; Chao, Ruo-Bing

    2014-06-01

    Aminoalcohol-diterpenoid alkaloids have been reported as the cardioactive components in the lateral roots of Aconitum carmichaeli (Fuzi) according to recent studies. Determination of these effective components is of great significance for quality control purposes for Fuzi. Here we report, for the first, the development and validation of a new method to determine the 13 aminoalcohol-diterpenoid alkaloids in Fuzi by using a simple and accurate solid-phase extraction-liquid chromatography-tandem mass spectrometry. The chromatographic analysis was performed on an ODS column with methanol-0.1 % formic acid (80 : 20, v/v) as the mobile phase. The quantification was performed using MS/MS detection in the positive ion mode with multiple reaction monitoring. Linearity was observed within a range of concentrations of 20-2,000 ng/mL. For all the analytes, the r value was greater than 0.9990. The limit of detection and the limit of quantitation were less than 0.5 ng/mL and 2.0 ng/mL, respectively. The intraday and interday precisions were less than 5% and 10%, respectively. The accuracy was within the range of 90 to 105%. This method was successfully applied to determine the 13 aminoalcohol-diterpenoid alkaloids in Fuzi from different origins and with different processing methods.

  14. Residue analysis and persistence evaluation of fipronil and its metabolites in cotton using high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wu, Xiaohu; Yu, Yang; Xu, Jun; Dong, Fengshou; Liu, Xingang; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2017-01-01

    A simple residue analytical method based on the QuEChERS approach and high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) detection was developed for the analysis of fipronil and its three metabolites in cottonseed, cotton plant and soil. The average recoveries of four test compounds from all three matrices were 78.6-108.9% at the level of 0.005 to 0.5 mg/kg, with an RSD in the range of 0.6 to 13.7%. The limit of quantification (LOQ) of the four test compounds ranged from 0.005 to 0.01 mg/kg. The results of the residual dynamics experiments showed that fipronil dissipated rapidly in cotton plants and soil and that oxidation and photolysis were the main degradation pathways. Moreover, the bi-exponential models demonstrated a good fit of the measured data for fipronil in cotton plants and soil, with R2 in the range of 0.8989 to 0.9989. Furthermore, a total of 40 samples of cottonseed from Shandong Province were analyzed, and all of the samples were free from the four test compound residues.

  15. Simultaneous determination of 15 aminoglycoside(s) residues in animal derived foods by automated solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tao, Yanfei; Chen, Dongmei; Yu, Huan; Huang, Lingli; Liu, Zhaoying; Cao, Xiaoqin; Yan, Caixia; Pan, Yuanhu; Liu, Zhenli; Yuan, Zonghui

    2012-11-15

    An automated method has been developed for the simultaneous quantification of 15 aminoglycosides in muscle, liver (pigs, chicken and cattle), kidney (pigs and cattle), cow milk, and hen eggs by liquid chromatography tandem mass spectrometry. Homogenized samples were extracted by monopotassium phosphate buffer (including ethylene diamine tetraacetic acid), and cleaned up with auto solid-phase extraction by carboxylic acid cartridges. The analytes were separated by a specialized column for aminoglycosides, and eluted with trifluoroacetic acid and acetonitrile. The decision limits (CCα) of apramycin, gentamycin, tobramycin, paromomycin, hygromycin, neomycin, kanamycin, sisomicin, netilmicin, ribostamycin, kasugamycin, amikacin, streptomycin, dihydrostreptomycin and spectinomycin were ranged from 8.1 to 11.8 μg/kg and detection capabilities (CCβ) from 16.4 to 21.8 μg/kg. High correlation coefficients (r(2)>0.99) of calibration curves for the analytes were obtained within linear from 20 to 1000 μg/kg. Reasonable recoveries (71-108%) were demonstrated with excellent relative standard deviation (RSD). This method is simple pretreatment, rapid determination and high sensitivity, which can be used in the determination of multi-aminoglycosides in complex samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Determination of nerve agent metabolites in human urine by isotope-dilution gas chromatography-tandem mass spectrometry after solid phase supported derivatization.

    Science.gov (United States)

    Lin, Ying; Chen, Jia; Yan, Long; Guo, Lei; Wu, Bidong; Li, Chunzheng; Feng, Jianlin; Liu, Qin; Xie, Jianwei

    2014-08-01

    A simple and sensitive method has been developed and validated for determining ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), and pinacolyl methylphosphonic acid (PMPA) in human urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) coupled with solid phase derivatization (SPD). These four alkyl methylphosphonic acids (AMPAs) are specific hydrolysis products and biomarkers of exposure to classic organophosphorus (OP) nerve agents VX, sarin, RVX, and soman. The AMPAs in urine samples were directly derivatized with pentafluorobenzyl bromide on a solid support and then extracted by liquid-liquid extraction. The analytes were quantified with isotope-dilution by negative chemical ionization (NCI) GC-MS/MS in a selected reaction monitoring (SRM) mode. This method is highly sensitive, with the limits of detection of 0.02 ng/mL for each compound in a 0.2 mL sample of human urine, and an excellent linearity from 0.1 to 50 ng/mL. It is proven to be very suitable for the qualitative and quantitative analyses of degradation markers of OP nerve agents in biomedical samples.

  17. Effect of six Chinese spices on heterocyclic amine profiles in roast beef patties by ultra performance liquid chromatography-tandem mass spectrometry and principal component analysis.

    Science.gov (United States)

    Zeng, Maomao; He, Zhiyong; Zheng, Zongping; Qin, Fang; Tao, Guanjun; Zhang, Shuang; Gao, Yahui; Chen, Jie

    2014-10-01

    The effects of Chinese spices on the profiles of 17 heterocyclic amines (HAs) from seven HA categories were investigated in roast beef patties using Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS) and principal component analysis. Three groups of HAs, imidazopyridines (PhIP, DMIP, and 1,5,6-TMIP), imidazoquinoxalines (MeIQx and 4,8-DiMeIQx), and β-carbolines (harman and norharman), were detected and quantified in all of the samples. The results demonstrated that the total HA and imidazopyridine profiles could clearly be affected by 1% pricklyash peel (14.1 ± 0.76 and 6.06 ± 0.32 ng/g), chilli (41.0 ± 0.01 and 23.0 ± 0.52 ng/g), and cumin (59.9 ± 2.44 and 31.1 ± 3.06 ng/g), in comparison with control values of 21.8 ± 2.40 and 14.3 ± 2.04 ng/g, respectively. The difference was only significant (p spices in meat processing to minimize HA formation.

  18. Dispersive Liquid-Liquid Microextraction Combined with Ultrahigh Performance Liquid Chromatography/Tandem Mass Spectrometry for Determination of Organophosphate Esters in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Haiying Luo

    2014-01-01

    Full Text Available A new technique was established to identify eight organophosphate esters (OPEs in this work. It utilised dispersive liquid-liquid microextraction in combination with ultrahigh performance liquid chromatography/tandem mass spectrometry. The type and volume of extraction solvents, dispersion agent, and amount of NaCl were optimized. The target analytes were detected in the range of 1.0–200 µg/L with correlation coefficients ranging from 0.9982 to 0.9998, and the detection limits of the analytes were ranged from 0.02 to 0.07 µg/L (S/N=3. The feasibility of this method was demonstrated by identifying OPEs in aqueous samples that exhibited spiked recoveries, which ranged between 48.7% and 58.3% for triethyl phosphate (TEP as well as between 85.9% and 113% for the other OPEs. The precision was ranged from 3.2% to 9.3% (n=6, and the interprecision was ranged from 2.6% to 12.3% (n=5. Only 2 of the 12 selected samples were tested to be positive for OPEs, and the total concentrations of OPEs in them were 1.1 and 1.6 µg/L, respectively. This method was confirmed to be simple, fast, and accurate for identifying OPEs in aqueous samples.

  19. Sensitive and Rapid Quantification of Felodipine by High-performance Liquid Chromatography-tandem Mass Spectrometry(HPLC-MS/MS) and Its Pharmacokinetics in Healthy Chinese Volunteers

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    To investigate the pharmacokinetics of felodipine in the plasma of healthy Chinese volunteers, 30 healthy volunteers received a single oral dose of 5 mg of extended release felodipine tablets. The felodipine was extracted from the matrix with a liquid-liquid extract procedure and analyzed by high-performance liquid chromatography-tandem mass spectrometry in the multiple reaction monitoring(MRM) mode using an electrospray ion source with positive ion detection. The method was validated over a felodipine concentration range of 0.05-10.00 ng/mL in human plasma. Its main pharmacokinetic parameters values were: ρmax=(1.67±0.84) ng/mL, occurring at (3.93±2.49) h; the plasma elimination half-life: (23.08±9.48) h and the area under the plasma concentration versus time curve: (29.94±14.39) ng·h/mL. The validation results demonstrated that this method showed a satisfactory precision and accuracy across the calibration range. The procedure involved minimal drug administration, sample preparation, and a 2.5-min chromatographic run time. It was well suited to clinical studies of the drug involving large numbers of samples.

  20. Microwave-assisted extraction and determination of cyanuric acid residue in pet food samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Han, Chao; Zhou, Yongfang; Xia, Biqi; Zhu, Zhenou; Liu, Cuiping; Shen, Yan

    2011-02-01

    Cyanuric acid (CYA) is attracting more attention due to its potential toxicity. In the present work, microwave-assisted extraction method in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was proposed for the determination of CYA in pet food samples. Among different solvents, diethylamine-acetonitrile-water mixture (1:5:4, v/v) was found to be the best one as the extractant due to the strong polarity of CYA in the pet food. An internal standard, (13) C(3) -labeled CYA, was used in the extractions. The separation was performed on a MERCK ZIC HILIC column (150 mm × 2.1 mm id, 5 μm) with gradient elution of 20 mM ammonium acetate solution-acetonitrile. CYA was well retained (Rt = 5.10 min) and eluted with good peak shape. The method could respond linearly with CYA at concentrations from 1.0 to 50 ng/mL with a quantification limit of 0.25 mg/kg. The intra- and inter-day precision was less than 4.0% and the recovery of the assay was in the range of 90.4-108.1%. In the analysis of practical spiked pet food samples, the new method yielded satisfactory results. Due to its simplicity and accuracy the straightforward method is particularly suitable for routine CYA detection. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. High-throughput determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study of two formulations in healthy volunteers.

    Science.gov (United States)

    Bi, Hui-Chang; Zhao, Li-zi; Zhong, Guo-ping; Zhou, Shufeng; Li, Bo; Deng, Ying; Chen, Xiao; Huang, Min

    2006-01-01

    A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to determine carbocysteine in human plasma was developed and fully validated. After methanol-induced protein precipitation of the plasma samples, carbocysteine was subjected to LC/MS/MS analysis using electrospray ionization (ESI). The MS system was operated in the selected ion monitoring (SRM) mode. Chromatographic separation was performed on a Hypurity C18 column (i.d. 2.1 mm x 50 mm, particle size 5 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 0.1-20 microg/mL for carbocysteine. The lower limit of quantification (LLOQ) of the method was 0.1 microg/mL for carbocysteine. The intra- and inter-day precision was less than 7% for all quality control samples at concentrations of 0.5, 2.0, and 10.0 microg/mL. These results indicate that the method was efficient with a simple preparation procedure and a very short running time (2.0 min) for carbocysteine compared with methods reported in the literature and had high selectivity, acceptable accuracy, precision and sensitivity. The validated LC/MS/MS method has been successfully used to a bioequivalence study of two tablet formulations of carbocysteine in healthy volunteers. Copyright 2006 John Wiley & Sons, Ltd.

  2. Comparison of antibody-conjugated magnetic immunoassay and liquid chromatography-tandem mass spectrometry for the measurement of cyclosporine and tacrolimus in whole blood.

    Science.gov (United States)

    Cangemi, G; Barco, S; Bonifazio, P; Maffia, A; Agazzi, A; Melioli, G

    2013-01-01

    The aim of this work is to compare the results of a commercially available liquid chromatography tandem mass spectrometry (LC-MS/MS) method in a clinical pathology laboratory for routine Therapeutic Drug Monitoring (TDM) of cyclosporine (CsA) and tacrolimus (Tacr) in pediatric patients with those obtained with the current antibody-conjugated magnetic immunoassay (ACMIA). Whole blood levels of CsA (n= 135) and Tacr (n=100) were sequentially analyzed by using ACMIA and LC-MS/MS on pediatric transplanted patients. The differences were analyzed by using the Passing Bablok regression analysis and the Bland and Altman test. The LC-MS/MS method showed excellent reproducibility and lower limits of quantification compared to the ACMIA. A linear relationship between ACMIA and LC-MS/MS was obtained for both CsA Tacr. No significant inter-method biases were observed. The analytical performances of the LC-MS/MS method make it suitable for the accurate measurement of CsA and Tacr in pediatric transplanted patients. However ACMIA results are also accurate and reliable. For this reason the choice of the method to be used in a routine clinical pathology laboratory can be made on the bases of non-analytical considerations such as costs, organization, availability of skilled personnel.

  3. Comprehensive study of the phenolics and saponins from Helleborus niger L. Leaves and stems by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Duckstein, Sarina M; Stintzing, Florian C

    2014-02-01

    The aerial parts of the medicinal plant Helleborus niger L. comprise a substantial number of constituents with only few of them identified so far. To expand the knowledge of its secondary metabolite profile, extracts from H. niger leaves and stems were investigated by liquid chromatography/tandem mass spectrometry (LC/MS(n) ). Specific identification strategies using LC/MS are established and discussed in detail. The leaves turned out to contain acylated and non-acylated quercetin and kaempferol oligoglycosides, protoanemonin and its precursor ranunculin, β-ecdysone, and a variety of steroidal saponins, mainly in the furostanol form. The sapogenins were elucidated as of sarsasapogenyl, diosgenyl, and macranthogenyl structures, and confirmed by comparison with the respective reference compounds. The secondary metabolite profiles were almost identical in both plant parts except that the stems lacked kaempferol derivatives and some saponins. The ranunculin derivatives and β-ecdysone were found in both plant parts. Correlations between the location of the compound groups and the plant's defense strategies are proposed. Additionally, the role of the detected secondary metabolites as protective substances against exogenic stress and as a defense against herbivores is discussed.

  4. Validation of a new liquid chromatography- tandem mass spectrometry ion-trap technique for the simultaneous determination of thirteen anticoagulant rodenticides, drugs, or natural products.

    Science.gov (United States)

    Fourel, Isabelle; Hugnet, Christophe; Goy-Thollot, Isabelle; Berny, Philippe

    2010-03-01

    The purpose of this study was to develop and validate a liquid chromatography-tandem mass spectrometry method for the identification and quantification of anticoagulant (anti-vitamin K or AVK) compounds, including rodenticides, drugs, and natural products because no published method could be found. The proposed method is based on ion-trap technology with electrospray ionization (ESI) and multiple reaction monitoring (MRM) technique. Each AVK is identified by means of its retention time, precursor ion, and two product ions. Plasma samples are extracted by liquid-liquid partition on Toxi-tube B((R)). The method was validated on dog plasma and gave good results in terms of specificity, linearity, and percent recovery for the 14 AVK tested (warfarin, acenocoumarol, bromadiolone, brodifacoum, chlorophacinone, coumatetralyl, dicoumarol, difenacoum, difethialone, flocoumafen, fluindione, phenindione, and tioclomarol). The limits of detection ranged from 5 to 25 ng/mL. Intraday repeatability was good, but interday repeatability was more variable though still sufficient for our diagnostic purposes. The technique was successfully applied in a series of clinical investigations to demonstrate its applicability in various animal species and gave very high sensitivity and specificity results.

  5. Determination of quinolones of veterinary use in bee products by ultra-high performance liquid chromatography-tandem mass spectrometry using a QuEChERS extraction procedure.

    Science.gov (United States)

    Lombardo-Agüí, Manuel; García-Campaña, Ana M; Gámiz-Gracia, Laura; Cruces-Blanco, Carmen

    2012-05-15

    A reliable and rapid ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the determination of the eight quinolones of veterinary use regulated by European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, flumequine and oxolinic acid). Chromatographic conditions were optimized in order to increase sample throughput and sensitivity. The antibiotics were detected by electrospray ionization in positive ion mode with multiple reaction monitoring (MRM) and MS/MS conditions were optimized in order to increase selectivity, selecting the corresponding product ions for quantification and identification. The separation was achieved in 3 min, using a Zorbax Eclipse Plus C18 column (50 mm × 2.1mm, 1.8 μm), with a mobile phase of 0.02% aqueous formic acid solution and acetonitrile. A dispersive solid phase extraction methodology, often referred to as the "QuEChERS" (quick, easy, cheap, effective, rugged, and safe) method, was optimized for extraction of the quinolones from honey and also it was evaluated for other bee products such as royal jelly and propolis. The method was validated for each matrix in terms of linearity, trueness, precision, limits of detection (LODs) and quantification (LOQ). LODs ranged between 0.2 and 4.1 μg kg(-1) with precision lower than 12% and satisfactory recoveries in most cases. The method was also applied for studying the occurrence of these antibiotics in several market samples.

  6. Multiresidue analysis of sulfonamides, quinolones, and tetracyclines in animal tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Zhiwen; Li, Xiaowei; Ding, Shuangyang; Jiang, Haiyang; Shen, Jianzhong; Xia, Xi

    2016-08-01

    A multiresidue method for the efficient identification and quantification of 38 compounds from 3 different classes of antibiotics (tetracyclines, sulfonamides, and quinolones) in animal tissues has been developed. The method optimization involved the selection of extraction solutions, comparison of different solid-phase extraction cartridges and different mobile phases. As a result, the samples were extracted with Mcllvaine and phosphate buffers, followed by clean-up step based on solid-phase extraction with Oasis HLB cartridge. All compounds were determined by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9min. The method efficiency was evaluated in 5 tissues including muscle, liver, and kidney, and the mean recoveries ranged from 54% to 102%, with inter-day relative standard deviation lower than 14%. The limits of quantification were between 0.5 and 10μg/kg, which were satisfactory to support future surveillance monitoring. The developed method was applied to the analysis of swine liver and chicken samples from local markets, and sulfamethazine was the most commonly detected compound in the animal samples, with the highest residue level of 998μg/kg.

  7. Rapid determination of endogenous cytokinins in plant samples by combination of magnetic solid phase extraction with hydrophilic interaction chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Liu, Zhao; Cai, Bao-Dong; Feng, Yu-Qi

    2012-04-01

    A 2-acrylamido-2-methyl-1-propanesulfonic acid-co-ethylene glycol dimethacrylate (Fe₃O₄/SiO₂/P(AMPS-co-EGDMA)) copolymer was prepared and used as a magnetic solid phase extraction (MSPE) medium for recovery of endogenous cytokinins (CKs) from plant extracts. This magnetic porous polymer was characterized by electron microscopy, nitrogen sorption experiments, elemental analysis and Fourier-transformed infrared spectroscopy. It was demonstrated to have high extraction capacity toward CKs in plants due to its specificity, surface area and porous structure. Coupled with hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS), a rapid, simple, and effective MSPE-HILIC-MS/MS analytical method for the quantitative analysis of endogenous CKs in Oryza sativa (O. sativa) roots was successfully established. Good linearities were obtained for all CKs investigated with correlation coefficients (R²>0.9975. The results showed that LODs (S/N=3) were ranged from 0.18 to 3.65 pg mL⁻¹. Reproducibility of the method was obtained with intra-day and inter-day relative standard deviations (RSDs) less than 16.1% and the recoveries in plant samples ranged from 72.8% to 115.5%. Finally, the MSPE-HILIC-MS/MS method was applied to several plant samples, and the amounts of endogenous CKs in O. sativa roots, leaves and Arabidopsis thaliana (A. thaliana) were successfully determined.

  8. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp.

    Science.gov (United States)

    Chen, Guoqiang; Hoptroff, Michael; Fei, Xiaoqing; Su, Ya; Janssen, Hans-Gerd

    2013-11-22

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal standard. Atmospheric pressure chemical ionization (APCI) in positive mode was applied for the detection of climbazole. For quantification, multiple reaction monitoring (MRM) transition 293.0>69.0 was monitored for climbazole, and MRM transition 296.0>225.1 for the deuterated climbazole. The linear range ran from 4 to 2000 ng mL(-1). The limit of detection (LOD) and the limit of quantification (LOQ) were 1 ng mL(-1) and 4 ng mL(-1), respectively, which enabled quantification of climbazole on artificial skin and human scalp at ppb level (corresponding to 16 ng cm(-2)). For the sampling of climbazole from human scalp the buffer scrub method using a surfactant-modified phosphate buffered saline (PBS) solution was selected based on a performance comparison of tape stripping, the buffer scrub method and solvent extraction in in vitro studies. Using this method, climbazole deposition in in vitro and in vivo studies was successfully quantified. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Liquid chromatography--tandem mass spectrometry method for simultaneous determination of albendazole and albendazole sulfoxide in human plasma for bioequivalence studies

    Directory of Open Access Journals (Sweden)

    Dhiraj M. Rathod

    2016-08-01

    Full Text Available An improved high performance liquid chromatography--tandem mass spectrometry (LC–MS/MS method has been developed for sensitive and rapid determination of albendazole (ABZ and its active metabolite, albendazole sulfoxide (ABZSO, in the positive ionization mode. The method utilized solid phase extraction (SPE for sample preparation of the analytes and their deuterated internal standards (ISs from 100 µL human plasma. The chromatography was carried out on Hypurity C18 column using acetonitrile-2.0 mM ammonium acetate, pH 5.0 (80:20, v/v as the mobile phase. The assay exhibited a linear response over the concentration range of 0.200–50.0 ng/mL for ABZ and 3.00–600 ng/mL for ABZSO. The recoveries of the analytes and ISs ranged from 86.03%–89.66% and 89.85%–98.94%, respectively. Matrix effect, expressed as IS-normalized matrix factors, ranged from 0.985 to 1.042 for the both analytes. The method was successfully applied for two separate studies in healthy subjects using single dose of 400 mg conventional tablets and 400 mg chewable ABZ tablets, respectively.

  10. Online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry for high throughput screening of anabolic steroids in horse urine.

    Science.gov (United States)

    Shin, Hyun Du; Suh, Joon Hyuk; Kim, Junghyun; Cho, Hyun-Deok; Lee, Su Duk; Han, Kwan Seok; Wang, Yu; Han, Sang Beom

    2017-10-25

    A high throughput method for simultaneous screening of anabolic steroids and their metabolites (4-esterendione, trenbolone, boldenone, oxandrolone, nandrolone, methandrostenolone, testosterone, 1-androstendione, ethisterone, normethandrolone, methyltestosterone, 16β-Hydroxystanozolol, epitestosterone, bolasterone, norethandrolone, danazol, stanozolol and androstadienone) in equine urine by online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry was developed. The use of turbulent flow chromatography could simplify pretreatment of horse urine, which has complex matrices as well as high viscosity. The urine was extracted by mixed-mode cation exchange solid phase extraction, and hydrolyzed using β-glucuronidase/arylsulfatase. Then, the sample was automatically loaded on the TurboFlow Cyclone extraction column for removal of further matrix, followed by separation on a fused core C18 column before MS/MS detection. Optimization and validation of the method were discussed in detail. All analytes were rapidly detected within 10min with high sensitivity (picogram to nanogram per milliliter level), and no interference was observed. The linearity range was from 0.1-10ng/mL for nine steroids and 1.0-50ng/mL for the others, with correlation of coefficient values over 0.995. Precision and accuracy ranged from 0.1 to 14.5% and 1.7 to 12.4%, respectively. The developed method was successfully applied to the analysis of anabolic steroids in horse urine after administration of a model drug. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Microwave-assisted extraction and determination of citrus red 2 dye in oranges and orange juice by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Han, Chao; Liu, Bin; Zhu, Zhenou; Huang, Fuzhen; Chen, Xiangzhun; Shen, Yan

    2012-12-01

    A fast, simple, low cost, and high-throughput method has been developed for the determination of citrus red 2 dye in orange and orange juice samples. The procedure is based on microwave-assisted extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The method was optimized, and the analyte was efficiently extracted from the samples in 30 min using hexane/acetone (v/v, 3 : 1). The method was validated and showed good linearity and selectivity. The limits of quantification (LOQs) were 5 μg/kg (sample size of 2 g) for both orange and orange juice samples. The average recoveries, measured at 3 concentration levels (5, 10, and 20 μg/kg), were in the range 77.5% to 87.6% for the compound tested with relative standard deviations below 7.3%. The proposed method is rapid, accurate, and could be utilized for the routine analysis of citrus red 2 dye in orange and orange juice samples.

  12. A Rapid Magnetic Solid Phase Extraction Method Followed by Liquid Chromatography-Tandem Mass Spectrometry Analysis for the Determination of Mycotoxins in Cereals

    Directory of Open Access Journals (Sweden)

    Giorgia La Barbera

    2017-04-01

    Full Text Available Mycotoxins can contaminate various food commodities, including cereals. Moreover, mycotoxins of different classes can co-contaminate food, increasing human health risk. Several analytical methods have been published in the literature dealing with mycotoxins determination in cereals. Nevertheless, in the present work, the aim was to propose an easy and effective system for the extraction of six of the main mycotoxins from corn meal and durum wheat flour, i.e., the main four aflatoxins, ochratoxin A, and the mycoestrogen zearalenone. The developed method exploited magnetic solid phase extraction (SPE, a technique that is attracting an increasing interest as an alternative to classical SPE. Therefore, the use of magnetic graphitized carbon black as a suitable extracting material was tested. The same magnetic material proved to be effective in the extraction of mycoestrogens from milk, but has never been applied to complex matrices as cereals. Ultra high–performance liquid chromatography tandem mass spectrometry was used for detection. Recoveries were >60% in both cereals, even if the matrix effects were not negligible. The limits of quantification of the method results were comparable to those obtained by other two magnetic SPE-based methods applied to cereals, which were limited to one or two mycotoxins, whereas in this work the investigated mycotoxins belonged to three different chemical classes.

  13. Determination of mycotoxins in milk-based products and infant formula using stable isotope dilution assay and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Kai; Wong, Jon W; Hayward, Douglas G; Vaclavikova, Marta; Liao, Chia-Ding; Trucksess, Mary W

    2013-07-03

    A stable isotope dilution assay and liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of 12 mycotoxins, aflatoxins B₁, B₂, G₁, G₂, and M₁, deoxynivalenol, fumonisins B₁, B₂, and B₃, ochratoxin A, T-2 toxin, and zearalenone, in milk-based infant formula and foods. Samples were fortified with 12 ¹³C uniformly labeled mycotoxins ([¹³C]-mycotoxins) that correspond to the 12 target mycotoxins and prepared by dilution and filtration, followed by LC-MS/MS analysis. Quantitation was achieved using the relative response factors of [¹³C]-mycotoxins and target mycotoxins. The average recoveries in fortified milk, milk-based infant formula, milk powder, and baby yogurt of aflatoxins B₁, B₂, G₁, and G₂ (2, 10, and 50 μg/kg), aflatoxin M₁ (0.5, 2.5, and 12.5 μg/kg), deoxynivalenol, fumonisins B₁, B₂, and B₃ (40, 200, and 1000 μg/kg), ochratoxin A, T-2 toxin, and zearalenone (20, 100, and 500 μg/kg), range from 89 to 126% with RSDs of mycotoxins, without using standard addition or matrix-matched calibration to compensate for matrix effects.

  14. Optimization of solid-phase-extraction cleanup and validation of quantitative determination of eugenol in fish samples by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Jincheng; Zhang, Jing; Liu, Yang

    2015-08-01

    This paper describes a rapid and sensitive method for the determination of eugenol in fish samples, based on solid-phase extraction (SPE) and gas chromatography-tandem mass spectrometry (GC-MS-MS). Samples were extracted with acetonitrile, and then cleanup was performed using C18 solid-phase extraction (SPE). The determination of eugenol was achieved using an electron-ionization source (EI) in multiple-reaction-monitoring (MRM) mode. Under optimized conditions, the average recoveries of eugenol were in the range 94.85-103.61 % and the relative standard deviation (RSD) was lower than 12.0 %. The limit of detection (LOD) was 2.5 μg kg(-1) and the limit of quantification (LOQ) was 5.0 μg kg(-1). This method was applied to an exposure study of eugenol residue in carp muscle tissues. The results revealed that eugenol was nearly totally eliminated within 96 h. Graphical Abstract Flow diagram for sample pretreatment.

  15. Determination of acrylamide and glycidamide in various biological matrices by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    Science.gov (United States)

    Kim, Tae Hwan; Shin, Soyoung; Kim, Kyu Bong; Seo, Won Sik; Shin, Jeong Cheol; Choi, Jin Ho; Weon, Kwon-Yeon; Joo, Sang Hoon; Jeong, Seok Won; Shin, Beom Soo

    2015-01-01

    Acrylamide (AA) is a heat-generated food toxicant formed when starchy foods are fried or baked. This study describes a simple and sensitive liquid chromatography-tandem mass spectrometry assay for the simultaneous quantification of AA and its active metabolite, glycidamide (GA) in rat plasma, urine, and 14 different tissues. The assay utilized a simple method of protein precipitation and achieved a lower limit of quantification of 5, 10 and 25 ng/mL of AA and 10, 20 and 100 ng/mL of GA for plasma, tissues and urine, respectively. The assay was fully validated to demonstrate the linearity, sensitivity, accuracy, precision, process recovery, and stability using matrix matched quality control samples. The mean intra- and inter-day assay accuracy was 91.6-110% for AA and 92.0-109% for GA, and the mean intra- and inter-day assay precisions were ≤ 10.9% for AA and ≤ 8.60% for GA. The developed method was successfully applied to a pharmacokinetic study of AA and GA following intravenous and oral administration of AA in rats. Tissue distribution characteristics of AA and GA were also determined under steady-state conditions.

  16. Simultaneous detection of perchlorate and bromate using rapid high-performance ion exchange chromatography-tandem mass spectrometry and perchlorate removal in drinking water.

    Science.gov (United States)

    West, Danielle M; Mu, Ruipu; Gamagedara, Sanjeewa; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Burken, Joel G; Shi, Honglan

    2015-06-01

    Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 μg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.

  17. Analysis of sulfonamides, tilmicosin and avermectins residues in typical animal matrices with multi-plug filtration cleanup by liquid chromatography-tandem mass spectrometry detection.

    Science.gov (United States)

    Qin, Yuhong; Jatamunua, Freedom; Zhang, Jingru; Li, Yanjie; Han, Yongtao; Zou, Nan; Shan, Jihao; Jiang, Yanbin; Pan, Canping

    2017-05-15

    The frequent use of various veterinary drugs could lead to residue bioaccumulation in animal tissues, which could cause dietary risks to human health. In order to quickly analyze the residues, a liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for detecting Sulfonamides, Tilmicosin and Avermectins (AVMs) residues in animal samples. For sample preparation, modified QuEChERS (quick, easy, cheap, effective, rugged and safe) and ultrasound-assisted extraction (UAE) methods were used. For sample cleanup, n-Hexane delipidation and multi-plug filtration cleanup (m-PFC) method based on primary-secondary amine (PSA) and octadecyl-silica (C18) were used, followed by LC-MS/MS analysis. It was validated on 7 animal matrices (bovine, caprine, swine meat and their kidneys, milk) at two fortified concentration levels of 5 and 100μg/kg. The recoveries ranged from 82 to 107% for all analytes with relative standard deviations (RSDs) less than 15%. Matrix-matched calibrations were performed with coefficients of determination above 0.998 for all analytes within concentration levels of 5-500μg/kg. The developed method was successfully used to analysis veterinary drugs of real animal samples from local markets. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Simple and Sensitive Analysis of Blonanserin and Blonanserin C in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry and Its Application

    Directory of Open Access Journals (Sweden)

    Yunliang Zheng

    2014-01-01

    Full Text Available A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6×150 mm, 3.5 μm column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A and 0.1% formic acid in methanol (B. To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012–5.78 ng·mL−1 for blonanserin and 0.023–11.57 ng·mL−1 for blonanserin C (r2>0.9990. The intra- and interday precision of three quality control (QC levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.

  19. Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study.

    Science.gov (United States)

    Ye, Ling; Shi, Jian; Wan, Shanhe; Yang, Xiaoshan; Wang, Ying; Zhang, Jiajie; Zheng, Dayong; Liu, Zhongqiu

    2013-11-01

    Topotecan (TPT) is an important anti-cancer drug that inhibits topoisomerase I. A sensitive and robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method that potentially determines TPT in beagle dog plasma is needed for a bioequivalence study of TPT formulations. We developed and validated LC-MS/MS to evaluate TPT in beagle dog plasma in terms of specificity, linearity, precision, accuracy, stability, extraction recovery and matrix effect. Plasma samples were treated with an Ostro(TM) sorbent plate (a robust and effective tool) to eliminate phospholipids and proteins before analysis. TPT and camptothecin (internal standard) were separated on an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 50 mm) with 0.1% formic acid and methanol as the mobile phase at a flow rate of 0.25 mL/min. TPT was analyzed using positive ion electrospray ionization in multiple-reaction monitoring mode. The obtained lower limit of quantitation was 1 ng/mL (signal-to-noise ratio > 10). The standard calibration curve for TPT was linear (correlation coefficient > 0.99) at the concentration range of 1-400 ng/mL. The intra-day and inter-day precision, accuracy, stability, extraction recovery and matrix effect of TPT were within the acceptable limits. The validated method was successfully applied in a bioequivalence study of TPT in healthy beagle dogs.

  20. Validation of a Liquid Chromatography Tandem Mass Spectrometry Method for Targeted Degradation Compounds of Ethanolamine Used in CO2 Capture: Application to Real Samples

    Directory of Open Access Journals (Sweden)

    Cuzuel Vincent

    2014-09-01

    Full Text Available In the field of greenhouse gas emission, a promising approach consists in CO2 storage and capture. However most of the processes are based on amine solutions which are likely to degrade and produce potentially harmful compounds. So there is a need for analytical methods to identify and quantify these products. Monoethanolamine was used as a model compound for the amines used for CO2 capture. A liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of six products of degradation of monoethanolamine (Glycine, N-(2-hydroxyethylglycine, N-glycylglycine, bicine, N,N′-bis-(2-hydroxyethyl urea (BHE Urea, and diethanolamine that were systematically detected with a LC-MS Scan method in real samples from CO2 capture and storage processes. The main difficulty of this study and its originality ly in the strategy developed to overcome the complexity of the matrix which is a mix of water and amine (70/30: the combined use of deuterated internal standards and a recent chemiometric approach to validate the method, i.e. the accuracy profile. For five compounds it was possible to validate the method with acceptance limits of 20%. This method was then successfully applied to real samples from pilot plant and lab-scale experiments.

  1. Determination of the neurotoxin BMAA (beta-N-methylamino-L-alanine) in cycad seed and cyanobacteria by LC-MS/MS (liquid chromatography tandem mass spectrometry).

    Science.gov (United States)

    Rosén, Johan; Hellenäs, Karl-Erik

    2008-12-01

    A highly specific method for the analysis of beta-N-methylamino-L-alanine (BMAA) by LC-MS/MS (liquid chromatography tandem mass spectrometry) has been developed and applied for cycad seeds and cyanobacteria. BMAA was analysed as a free fraction or as total BMAA after acidic hydrolysis to release any protein-bound BMAA. Deuterium labelled BMAA was synthesised and used as internal standard. The method comprises HILIC (hydrophilic interaction chromatography) and positive electrospray ionisation of the native compound, i.e. no derivatisation was used. For safe identification five specific product ions (m/z 102, 88, 76, 73 and 44), all derived from a precursor ion of m/z 119 and originating from different parts of the molecule, were detected (typical relative abundance 100%, 16%, 14%, 12% and 22% respectively). Cyanobacteria or muscle tissue was spiked with BMAA (10 to 1000 microg g(-1)) to validate the method (accuracy 95% to 109%, relative standard deviation 1% to 6%). The detection limit for free and total BMAA in tissue was cycad seeds, whereas previously reported findings of BMAA in samples of cyanobacteria could not be confirmed. Instead, the presence of alpha-,gamma-diamino butyric acid (DAB), an isomer of BMAA, was confirmed in one sample. The possible implications of this finding are discussed.

  2. Development of an online microbore hollow fiber enzyme reactor coupled with nanoflow liquid chromatography-tandem mass spectrometry for global proteomics.

    Science.gov (United States)

    Kim, Jin Yong; Lee, Sun Young; Kim, Sook-Kyung; Park, Sang Ryoul; Kang, Dukjin; Moon, Myeong Hee

    2013-06-04

    In this study, we report the development of a microbore hollow fiber enzyme reactor (mHFER) coupled to nanoflow liquid chromatography-tandem mass spectrometry (nLC-ESI-MS/MS) for the online digestion or selective enrichment of glycopeptides and analysis of proteins. With mHFER, enzymatic digestion of protein could be achieved by continuous flow within a very small volume (~10 μL) of mHF inserted in a PEEK tube. Digested peptides exited through the pores of the hollow fiber membrane wall to external single or multiplexed trap columns for nLC-ESI-MS/MS analysis. Evaluation of online mHFER-nLC-ESI-MS/MS system was made with bovine serum albumin (BSA) by varying the temperature of digestion and the amount of protein injected. We evaluated the ability of the mHFER system to enrich glycopeptides by injecting a mixture of lectin (concanavalin A) and digested peptides from α-1-acid glycoprotein (AGP) into the mHFER, followed by delivery of PNGase F for endoglycosidic digestion. Nonglycosylated peptides unbound to lectins eluted at the first breakthrough run while N-linked glycopeptides eluted after the endoglycosidic digestion. The developed method was applied to urine samples from patients with prostate cancer and controls; 67 N-linked glycopeptides were identified and relative differences in glycopeptide content between patient and control samples were determined.

  3. Validation of method for determination of different classes of pesticides in aqueous samples by dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometric detection.

    Science.gov (United States)

    Caldas, Sergiane Souza; Costa, Fabiane Pinho; Primel, Ednei Gilberto

    2010-04-14

    In this study, a simple, rapid and efficient method has been developed for the extraction and preconcentration of different classes of pesticides, carbofuran (insecticide), clomazone (herbicide) and tebuconazole (fungicide) in aqueous samples by dispersive liquid-liquid microextraction (DLLME) coupled with liquid chromatography-tandem mass spectrometric detection. Some experimental parameters that influence the extraction efficiency, such as the type and volume of the disperser solvents and extraction solvents, extraction time, speed of centrifugation, pH and addition of salt were examined and optimized. Under the optimum conditions, the recoveries of pesticides in water at spiking levels between 0.02 and 2.0 microg L(-1) ranged from 62.7% to 120.0%. The relative standard deviations varied between 1.9% and 9.1% (n=3). The limits of quantification of the method considering a 50-fold preconcentration step were 0.02 microg L(-1). The linearity of the method ranged from 1.0 to 1000 microg L(-1) for all compounds, with correlation coefficients varying from 0.9982 to 0.9992. Results show that the method we propose can meet the requirements for the determination of pesticides in water samples. The comparison of this method with solid-phase extraction indicates that DLLME is a simple, fast, and low-cost method for the determination of pesticides in natural waters.

  4. Development of liquid chromatography-tandem mass spectrometry method for analysis of polyphenolic compounds in liquid samples of grape juice, green tea and coffee.

    Science.gov (United States)

    Sapozhnikova, Yelena

    2014-05-01

    A simple and fast method for the analysis of a wide range of polyphenolic compounds in juice, tea, and coffee samples was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was based on a simple sample preparation "dilute and shoot" approach, and LC-MS/MS quantification using genistein-d4 as an internal standard. The performance of six different syringeless filter devices was tested for sample preparation. The method was evaluated for recoveries of polyphenols at three spiking levels in juice, tea, and coffee samples. The recoveries of the majority of polyphenols were satisfactory (70-120%), but some varied significantly (20-138%) depending on the matrix. NIST Standard Reference Materials (SRM) 3257 Catechin Calibration Solutions and 3255 Camellia sinensis (Green Tea) Extract with certified concentrations of catechin and epicatechin were used for method validation. The measurement accuracy in two SRMs was 71-113%. The method was successfully applied to the analysis of liquid samples of grape juice, green tea, and coffee.

  5. Rapid and sensitive determination of acetylsalicylic acid and salicylic acid in plasma using liquid chromatography-tandem mass spectrometry: application to pharmacokinetic study.

    Science.gov (United States)

    Xu, Xiangrong; Koetzner, Lee; Boulet, Jamie; Maselli, Harry; Beyenhof, Jessica; Grover, Gary

    2009-09-01

    A simple and sensitive analytical method using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of acetylsalicylic acid (aspirin, ASA) and its major metabolite, salicylic acid (SA), in animal plasma has been developed and validated. Both ASA and SA in plasma samples containing potassium fluoride were extracted using acetonitrile (protein precipitation) with 0.1% formic acid in it. 6-Methoxysalicylic acid was used as the internal standard (IS). The compounds were separated on a reversed-phase column. The multiple reaction monitoring mode was used with ion transitions of m/z 178.9 --> 136.8, 137.0 --> 93.0 and 167.0 --> 123.0 for ASA, SA and IS, respectively. The lower limits of quantification for ASA and SA were 3 and 30 ng/mL, respectively. The developed method was successfully applied for the evaluation of pharmacokinetics of ASA and SA after p.o. and i.v. administration of 1 mg/kg to rats.

  6. Identification and discrimination of three common Aloe species by high performance liquid chromatography-tandem mass spectrometry coupled with multivariate analysis.

    Science.gov (United States)

    Zhao, Yan; Sun, Ya Nan; Lee, Min Jung; Kim, Young Ho; Lee, Wonjae; Kim, Kyeong Ho; Kim, Kyung Tae; Kang, Jong Seong

    2016-09-15

    Aloe arborescens, Aloe barbadensis and Aloe ferox are the most widely cultivated and used among 500 aloe species due to their potent bioactivity. However, the difference of aloe species is neglected and labeled only one name Aloe in the market without specifying aloe species discrimination in general. Furthermore, differences in bioactivity and side effects from different aloe species have not been well investigated. This study develops an effective method for simultaneous qualitative and quantitative determination of three common aloe species using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and high performance liquid chromatography-diode array detection (HPLC-DAD). The extraction conditions were optimized by response surface methodology (RSM) based on methanol concentration, extraction time and solvent-to-material ratio. A partial least squares-discriminant analysis (PLS-DA) was used to identify the three aloe species. The developed HPLC-MS/MS method coupled with multivariate analysis can be applied to discriminate three aloe species successfully. Copyright © 2016. Published by Elsevier B.V.

  7. Simultaneous determination of ambroxol and salbutamol in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    Science.gov (United States)

    Guo, Zhening; Chen, Yangsheng; Ding, Xiaoliang; Huang, Chenrong; Miao, Liyan

    2016-11-01

    A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry assay method was developed for simultaneous determination of ambroxol and salbutamol in human plasma using citalopram hydrobromide as internal standard (IS). The sample was alkalinized with ammonia water (33:67, v/v) and extracted by single liquid-liquid extraction with ethyl acetate. Separation was achieved on Waters Acquity UPLC BEH C18 column using a gradient program at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 378.9 → 263.6 (ambroxol), m/z 240.2 → 147.7 (salbutamol) and m/z 325.0 → 261.7 (IS). The total analytical run time was relatively short (3 min). Calibration curves were linear in the concentration range of 0.5-100.0 ng/mL for ambroxol and 0.2-20.0 ng/mL for salbutamol, with intra- and inter-run precision (relative standard deviation) salbutamol. The method was successfully applied in a clinical pharmacokinetic study of the compound ambroxol and salbutamol tablets.

  8. Simple and sensitive analysis of blonanserin and blonanserin C in human plasma by liquid chromatography tandem mass spectrometry and its application.

    Science.gov (United States)

    Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; Shentu, Jianzhong

    2014-01-01

    A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5  μ m) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012-5.78 ng·mL(-1) for blonanserin and 0.023-11.57 ng·mL(-1) for blonanserin C (r (2) > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.

  9. Determination of pesticide residues in wine by membrane-assisted solvent extraction and high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Moeder, M; Bauer, C; Popp, P; van Pinxteren, M; Reemtsma, T

    2012-06-01

    The determination of pesticides in food products is an essential issue to guarantee food safety and minimise health risks of consumers. A protocol based on membrane-assisted solvent extraction and liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) that allows the determination of 18 pesticides in red wine at minimum labour effort for sample preparation was developed and validated. Ten millilitres of wine were extracted using 100 μL of toluene filled in a non-porous polyethylene membrane bag which is immersed in the wine sample. After 150 min extraction under stirring, an aliquot of the extraction solution is analysed using HPLC-MS/MS. The limits of quantification ranged from 3 ng/L for Pirimicarb to 1.33 μg/L for Imidacloprid. Quantification by matrix-matched calibration provided relative standard deviations ≤16 % for most of the target pesticides. The linearity of calibration was given over three to four orders of magnitude, which enables the reliable measurement of a broad range of pesticide concentrations, and for each target pesticide, the sensitivity of the protocol meets the maximum residue levels set by legislations at least for wine grapes. Good agreement of results was found when the new method was compared with a standard liquid-liquid extraction protocol. In five wine samples analysed, Carbendazim and Metalaxyl were determined at micrograms per litre concentrations, even in some of the organic wines. Tebuconazol and Cyprodinitril were determined at lower abundance and concentration, followed by Spiroxamin and Diuron.

  10. Microwave-assisted extraction and large-volume injection gas chromatography tandem mass spectrometry determination of multiresidue pesticides in edible seaweed.

    Science.gov (United States)

    García-Rodríguez, D; Carro, A M; Cela, R; Lorenzo, R A

    2010-09-01

    A microwave-assisted extraction method followed by clean-up with solid-phase extraction (SPE) combined with large-volume injection gas chromatography-tandem mass spectrometry (LVI-GC-MS/MS) for the analysis of 17 pesticides in wild and aquaculture edible seaweeds has been developed. An experimental central composite design was employed to evaluate the effects of the main variables potentially affecting the extraction (temperature, time, and solvent volume) and to optimize the process. The most effective microwave extraction conditions were achieved at 125 °C and 12 min with 24 mL of hexane/ethyl acetate (80:20). SPE clean-up of the extracts with graphitized carbon and Florisil, optimized by means of the experimental design, proved to be efficient in the removal of matrix interferences. The analytical recoveries were close to 100% for all the analytes, with relative standard deviations lower than 13%. The limits of detection ranged from 0.3 to 23.1 pg g(-1) and the limits of quantification were between 2.3 and 76.9 pg g(-1), far below the maximum residue levels established by the European Union for pesticides in seaweed. The results obtained prove the suitability of the microwave-assisted extraction for the routine analysis of pesticides in aquaculture and wild seaweed samples.

  11. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  12. Development of a rapid method for the determination and confirmation of nitroimidazoles in six matrices by fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tölgyesi, Adám; Sharma, Virender K; Fekete, Szabolcs; Fekete, Jenő; Simon, Andrea; Farkas, Szilvia

    2012-05-01

    A rapid liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed to identify and to quantify nitroimidazoles, metronidazole (MNZ), ronidazole (RNZ) and dimetridazole (DMZ) and their corresponding hydroxy metabolites, MNZ-OH and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMNNI) in plasma, milk, muscle, egg, honey and feed samples. The same sample clean-up procedure including a novel solid-phase extraction (SPE) on polymeric Strata-SDB cartridges was used for each matrix. The analytes were separated on Kinetex XB C-18 core-shell type HPLC column using isocratic elution mode with a mobile phase containing 0.1% formic acid in water/methanol (88/12, v/v, pH 2.6) at a flow rate of 0.7 ml/min. The main advantage of the developed method is that the analysis time of only 3 min, which is about three to ten times shorter than in other reported HPLC methods. The developed method was validated using a matrix-comprehensive in-house validation strategy. The matrix effect of LC-MS/MS analysis was also investigated. Results are presented from the successful application of the developed method to an incurred pork meat certified reference material and to incur porcine plasmas in a proficiency test in year 2011. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Evaluating misoprostol content in pregnant women with hourly oral administration during labor induction by microElution solid phase extraction combined with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hung, Cheng-Han; Cheng, Shi-Yann; Chan, Tzu-Min; Lee, Maw-Rong

    2015-09-01

    Misoprostol is a widely used alternative of prostaglandin for labor induction. Based on previous studies, we envision that small and frequent oral dosage of misoprostol is an effective method for labor induction. To monitor the misoprostol content during labor induction, a rapid, sensitive, and selective microElution solid phase extraction (μElution SPE) combined with liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. Using μElution SPE could minimize the sample consumption and elution volume in order to maximize the sample enrichment and throughput. The misoprostol acid, a metabolite of misoprostol, was gradient separated in a Bidentate C18 column, then quantified by highly-selective reaction monitoring (H-SRM) in a total run time of 6min. The developed method was optimized and validated in human plasma, and showed linear range of 0.01-10ng/mL. The limit of detection (LOD) was 0.001ng/mL. The recovery ranged from 89.0 to 96.0%, and no significant matrix effect or carryover was observed. The precision, accuracy and stability were met with the criteria of U.S. FDA guidance. The developed method was successfully applied to evaluate misoprostol concentration during labor induction in pregnant women. The concentration-time profiles approves that hourly oral administration of misoprostol is a safe and effective method without drug accumulation for labor induction.

  14. Survey of Deoxynivalenol and Aflatoxin B1 in Instant Noodles and Bread Consumed in Thailand by Using Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Pralatnet, Sasithorn; Poapolathep, Saranya; Giorgi, Mario; Imsilp, Kanjana; Kumagai, Susumu; Poapolathep, Amnart

    2016-07-01

    One hundred wheat product samples (50 instant noodle samples and 50 bread samples) were collected from supermarkets in Bangkok, Thailand. Deoxynivalenol (DON) and aflatoxin B1 (AFB1) contamination in these products was analyzed using a validated liquid chromatography-tandem mass spectrometry method. The limit of quantification values of DON and AFB1 in the instant noodles and bread were 2 and 1 ng g(-1), respectively. The survey found that DON was quantifiable in 40% of collected samples, in 2% of noodles (0.089 μg g(-1)), and in 78% of breads (0.004 to 0.331 μg g(-1)). AFB1 was below the limit of quantification of the method in all of the tested samples. The results suggest that the risk of DON exposure via noodles and breads is very low in urban areas of Thailand. No risk can be attributable to AFB1 exposure in the same food matrices, but further studies with a larger sample size are needed to confirm these data.

  15. Quantitative determination of corticosteroids in bovine milk using mixed-mode polymeric strong cation exchange solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tölgyesi, Adám; Tölgyesi, László; Sharma, Virender K; Sohn, Mary; Fekete, Jeno

    2010-12-01

    A new method was developed to identify and quantify corticosteroids (prednisolone, methylprednisone, flumetasone, dexamethasone, and methylprednisolone) in raw bovine milk by liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing mixed-mode polymeric strong cation exchange and reversed-phase (MCX) solid-phase extraction (SPE) to reduce ion effects in a multimode ion (MMI) source. The main advantage of this method over other commonly used methods includes the use of a single SPE cartridge with a low volume for sample preparation and fast separation on the HPLC system with reduced ion suppression. This study is the first to report the determination of methylprednisone, a metabolite of methylprednisolone, in bovine milk. This method was validated in accordance with the European Union (EU) Commission Decision 2002/657/EC. The recoveries vary between 90% and 105%. The within-laboratory reproducibility (precision) is less than 30%. The decision limits and detection capabilities were calculated along with LODs, which ranged from 0.02 to 0.07 microg/kg. The method was further enhanced by its successful adaptation to other LC-MS/MS systems equipped with the newly developed ion source, Agilent Jet Stream (AJS). After optimization of the AJS ion source and MS parameters, even lower LOD values were achieved (0.001-0.006 microg/kg) for the corticosteroids. Analytical results obtained with the AJS were characterized by an enhanced area response and similar noise level comparable to those obtained with conventional orthogonal atmospheric ionization (API).

  16. Automated liquid chromatography-tandem mass spectrometry method for the analysis of firocoxib in urine and plasma from horse and dog.

    Science.gov (United States)

    Letendre, Laura; Kvaternick, Valerie; Tecle, Berhane; Fischer, James

    2007-06-15

    A rugged, sensitive and efficient liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of firocoxib in urine from 5 to 3000 ng/mL and in plasma from 1 to 3000 ng/mL. The method requires 200 microL of either plasma or urine and includes sample preparation in 96-well solid phase extraction (SPE) plates using a BIOMEK 2000 Laboratory Automated Workstation. Chromatographic separation of firocoxib from matrix interferences was achieved using isocratic reversed phase chromatography on a PHENOMENEX LUNA Phenyl-Hexyl column. The mobile phase was 45% acetonitrile and 55% of a 2 mM ammonium formate buffer. The method was accurate (88-107%) and precise (CV93% were achieved and ionization efficiencies (due to matrix effects) were >72%. Extensive stability and ruggedness testing was also performed; therefore, the method can be used for pharmacokinetic studies as well as drug monitoring and screening. The data presented here is the first LC-MS/MS method for the quantitation of firocoxib in plasma (LLOQ of 1 ng/mL), a 25-fold improvement in sensitivity over the HPLC-UV method and the first quantitative method for firocoxib in urine (LLOQ of 5 ng/mL). Additionally the sample preparation process has been automated to improve efficiency.

  17. Determination of tulobuterol in rat plasma using a liquid chromatography-tandem mass spectrometry method and its application to a pharmacokinetic study of tulobuterol patch.

    Science.gov (United States)

    Han, Xiao; Liu, Ran; Ji, Lifang; Hui, Mei; Li, Qing; Fang, Liang; Bi, Kaishun

    2016-01-01

    A sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for determination of tulobuterol in rat plasma for the first time. Plasma samples were extracted by liquid-liquid extraction method with methyl tert-butyl ether and the analyte and clenbuterol (IS) were separated on a Venusil MP C18 column (100mm×2.1mm, 3μm) using 0.1% formic acid-water-methanol as mobile phase, with a runtime of 5min. The analyte was detected in multiple reaction monitoring (MRM) mode with positive electrospray ionization. Transitions of m/z 228.2→154.0 for tulobuterol and m/z 277.1→203.0 for the clenbuterol were monitored. The linear range was 0.5-100ng/ml (r=0.9967) for tulobuterol with the lower limit of quantitation of 0.5ng/ml. The intra-day and inter-day precisions were less than 10.3% for the analyte and the accuracy was less than -8.6%. The RSD of matrix effect and recovery yield were within ±15% of nominal concentrations and tulobuterol was stable during stability studies. The validated method has been successfully applied to a pharmacokinetic study of three doses of tulobuterol patch in rats for the first time.

  18. Automated hollow-fiber liquid-phase microextraction coupled with liquid chromatography/tandem mass spectrometry for the analysis of aflatoxin M₁ in milk.

    Science.gov (United States)

    Huang, Siming; Hu, Du; Wang, Ying; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng

    2015-10-16

    An automated hollow fiber liquid-phase microextraction (HF-LPME) coupled with liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the extraction and determination of aflatoxin M1 (AFM1) in milk samples. Parameters affecting the extraction efficiency, such as the extraction phase, matrix conditions, extraction time and temperature, were investigated. Under the optimal conditions (ratio of water to milk, 4:1; extraction time, 50 min; extraction temperature, 50°C; extraction phase, 50 mg L(-1) anti-AFM1 antibody in PBS buffer solution; volume of HCl solution, 250 μL; agitation speed, 250 rpm), the matrix-matched calibration curve for AFM1 determination showed good linearity in the range of 0.25-5 μg kg(-1). The enrichment factor (EF) reached 48, and the limits of detection and quantification were 0.06 and 0.21 μg kg(-1), respectively. The developed method was successfully applied for the extraction of AFM1 from spiked milk samples, with recoveries from 61.0% to 106.7%. The method was highly specific to AFM1 analysis, and the results demonstrated that the method can be automated, inexpensive, and free from interference.

  19. Simultaneous determination of naringin, hesperidin, neohesperidin, naringenin and hesperetin of Fractus aurantii extract in rat plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Tong, Ling; Zhou, Dandan; Gao, Jun; Zhu, Yonghong; Sun, He; Bi, Kaishun

    2012-01-25

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of naringin, hesperidin, neohesperidin, naringenin and hesperetin in rat plasma, using liquiritin as the internal standard. Plasma samples extracted with a solid-phase extraction procedure were separated on a Zorbax SB-C18 analytical column (2.1 mm × 150 mm, 5 μm) and detected by electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curves were linear over the range of 3.0-600 ng/ml for naringin, 0.5-100 ng/ml for hesperidin, 3.5-700 ng/ml for neohesperidin, 5.0-1000 ng/ml for naringenin and hesperetin, respectively. The lower limits of quantification were 0.5 ng/ml for naringin, hesperidin, naringenin and hesperetin, and 0.35 ng/ml for neohesperidin. Intra- and inter-day precision (RSD%) was less than 15% and accuracy (RE%) ranged from -3.3% to 4.8%. The validated method was successfully applied to investigate the pharmacokinetics of the major flavanones of Fructus aurantii extract after oral administration to rats.

  20. A reliable liquid chromatography-tandem mass spectrometry method for simultaneous determination of multiple mycotoxins in fresh fish and dried seafoods.

    Science.gov (United States)

    Sun, Wenshuo; Han, Zheng; Aerts, Johan; Nie, Dongxia; Jin, Mengtong; Shi, Wen; Zhao, Zhiyong; De Saeger, Sarah; Zhao, Yong; Wu, Aibo

    2015-03-27

    A reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous determination of nine mycotoxins, i.e., aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2), ochratoxin A (OTA), zearalenone (ZEN), T-2 toxin, HT2 toxin and deoxynivalenol (DON), in fresh fish (muscle and entrails) as well as dried seafoods. Special focus was given to sample pretreatment which is crucial for an accurate and reliable analytical method. With regards to the high complexity of the matrices, extraction solvent, time, and temperature as well as clean-up cartridges were optimized to improve extraction efficiency and reduce matrix effects. The optimum procedure included ultrasound-assisted extraction with acetonitrile/water/acetic acid (79/20/1, v/v/v) at 40 °C for 30 min, defatting with n-hexane and purification by Oasis HLB cartridges. The method was further validated by determining the linearity (R(2) ≥ 0.9989), sensitivity (limit of detection ≤ 2 μg/kg, limit of quantitation ≤ 3 μg/kg), recovery (72.2-119.9%) and precision (≤ 18.3%) in muscle and entrails of fresh crucian carp (Carassius carassius) as well as dried fish products. The method was proven to be suitable for its intended purposes. Mycotoxins of OTA, ZEN and AFB2 have been found in fresh fish and dried seafoods for the first time.

  1. Identification and quantification of peptides and proteins secreted from prostate epithelial cells by unbiased liquid chromatography tandem mass spectrometry using goodness of fit and analysis of variance.

    Science.gov (United States)

    Florentinus, Angelica K; Bowden, Peter; Sardana, Girish; Diamandis, Eleftherios P; Marshall, John G

    2012-02-01

    The proteins secreted by prostate cancer cells (PC3(AR)6) were separated by strong anion exchange chromatography, digested with trypsin and analyzed by unbiased liquid chromatography tandem mass spectrometry with an ion trap. The spectra were matched to peptides within proteins using a goodness of fit algorithm that showed a low false positive rate. The parent ions for MS/MS were randomly and independently sampled from a log-normal population and therefore could be analyzed by ANOVA. Normal distribution analysis confirmed that the parent and fragment ion intensity distributions were sampled over 99.9% of their range that was above the background noise. Arranging the ion intensity data with the identified peptide and protein sequences in structured query language (SQL) permitted the quantification of ion intensity across treatments, proteins and peptides. The intensity of 101,905 fragment ions from 1421 peptide precursors of 583 peptides from 233 proteins separated over 11 sample treatments were computed together in one ANOVA model using the statistical analysis system (SAS) prior to Tukey-Kramer honestly significant difference (HSD) testing. Thus complex mixtures of proteins were identified and quantified with a high degree of confidence using an ion trap without isotopic labels, multivariate analysis or comparing chromatographic retention times.

  2. Development of a multi-preservative method based on solid-phase microextraction-gas chromatography-tandem mass spectrometry for cosmetic analysis.

    Science.gov (United States)

    Alvarez-Rivera, Gerardo; Vila, Marlene; Lores, Marta; Garcia-Jares, Carmen; Llompart, Maria

    2014-04-25

    A simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of different classes of preservatives including benzoates, bronidox, 2-phenoxyethanol, parabens, BHA, BHT and triclosan in cosmetic products. In situ acetylation and subsequent organic modifier addition have been successfully implemented in the SPME process as an effective extractive strategy for matrix effect compensation and chromatographic performance improvement. Main factors affecting SPME procedure such as fiber coating, sampling mode, extraction temperature and salt addition (NaCl) were evaluated by means of a 3×2(3-1) factorial experimental design. The optimal experimental conditions were established as follows: direct solid-phase microextraction (SPME) at 40°C and addition of NaCl (20%, w/v), using a DVB/CAR/PDMS fiber coating. Due to the complexity of the studied matrices, method performance was evaluated in a representative variety of both rinse-off and leave-on samples, demonstrating to have a broad linear range (R(2)>0.9964). In general, quantitative recoveries (>85% in most cases) and satisfactory precision (RSDcreams, deodorants, sunscreen, bath gel, dental cream and make-up products amongst others, demonstrating to be a reliable multi-preservative methododology for routine control.

  3. Validation of a liquid chromatography-tandem mass spectrometry method for the detection of nicotine biomarkers in hair and an evaluation of wash procedures for removal of environmental nicotine.

    Science.gov (United States)

    Miller, Eleanor I; Murray, Gordon J; Rollins, Douglas E; Tiffany, Stephen T; Wilkins, Diana G

    2011-07-01

    The aim of this exploratory study was to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantification of nicotine, eight nicotine metabolites, and two minor tobacco alkaloids in fortified analyte-free hair and subsequently apply this method to hair samples collected from active smokers. An additional aim of the study was to include an evaluation of different wash procedures for the effective removal of environmentally deposited nicotine from tobacco smoke. An apparatus was designed for the purpose of exposing analyte-free hair to environmental tobacco smoke in order to deposit nicotine onto the hair surface. A shampoo/water wash procedure was identified as the most effective means of removing nicotine. This wash procedure was utilized for a comparison of washed and unwashed heavy smoker hair samples. Analytes and corresponding deuterated internal standards were extracted using a cation-exchange solid-phase cartridge. LC-MS-MS was carried out using an Acquity™ UPLC(®) system (Waters) and a Quattro Premier XE™ triple quadrupole MS (Waters) operated in electrospray positive ionization mode, with multiple reaction monitoring data acquisition. The developed method was applied to hair samples collected from heavy smokers (n = 3) and low-level smokers (n = 3) collected through IRB-approved protocols. Nicotine, cotinine, and nornicotine were quantified in both the washed and unwashed hair samples collected from three heavy smokers, whereas 3-hydroxycotinine was quantified in only one unwashed sample and nicotine-1'-oxide in the washed and unwashed hair samples from two heavy smokers. In contrast, nicotine-1'-oxide was quantified in one of the three low-level smoker samples; nicotine was quantified in the other two low-level smoker samples. No other analytes were detected in the hair of the three low-level smokers.

  4. Effective clean-up and ultra high-performance liquid chromatography-tandem mass spectrometry for isoflavone determination in legumes.

    Science.gov (United States)

    Vila-Donat, Pilar; Caprioli, Giovanni; Maggi, Filippo; Ricciutelli, Massimo; Torregiani, Elisabetta; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    Legumes are an excellent source of macronutrients and phytochemicals as isoflavones. The aim of this work was to develop a new analytical method for determining five isoflavone compounds, three of which are aglycons, namely daidzein, genistein, biochanin A, and two of which, daidzin and genistin, are glycosilated, in lentils and other pulses, using an effective clean-up system and UHPLC-MS/MS (triple quadrupole) method. The recoveries obtained by spiking the lentil samples with a standard mixture of isoflavones at three levels of fortification (5, 25 and 100 μg kg(-1)) were in the range of 54.4-111.1%, 68.6-91.1%, and 84.4-114%, respectively. The method was applied to analyse 48 lentil samples from central Italy and pulses for determining the isoflavone content, which was found to range from 1.1 to 95.6 μg kg(-1).

  5. Applications of Liquid Chromatography-Tandem Mass Spectrometry to Detection and Characterization of Reactive Metabolites%液相色谱-串联质谱法检测反应性代谢物

    Institute of Scientific and Technical Information of China (English)

    谢岑; 钟大放; 陈笑艳

    2011-01-01

    A number of therapeutical drugs were reported to undergo metabolic activation by drug-metabolizing enzymes. The bioactivation forms reactive metabolite(s), which readily covalently bind to macromolecules, such as proteins and DNA, and then lead to toxicities.In recent years, screening drug candidates for their tendency to generate reactive metabolites during drug discovery and development process and as well monitoring the bioactivation for post-marketing drugs have become increasingly important. Most reactive metabolites are electrophilic in nature and can react with nucleophiles. In vitro microsomal incubations,small nucleophilic molecules, such as glutathione, cyanide and amines are generally used to trap reactive metabolites. Structural elucidation of these stable adducts are conducted by liquid chromatography-tandem mass spectrometry. In this review, different mass spectrometers including triple quadrupole, ion trap, quadrupole-linear ion trap, and high-resolution mass spectrometer, employed for assessing reactive metabolites are described. The recent advances of different techniques and approaches are also discussed.%已有报道一些药物进入体内后在各种代谢酶的作用下转化为反应性代谢物,然后与生物大分子(如蛋白、DNA)共价结合,导致毒性.在药物发现和开发阶段进行反应性代谢物筛查,对上市药物进行反应性代谢物监测已经成为一个重要的研究领域.通常,反应性代谢物具有亲电性,能被小分子亲核试剂(如谷胱甘肽及其衍生物、氰离子、胺类等)体外捕获,采用液相色谱-串联质谱法检测并鉴定这些结合物的结构是研究反应性代谢物的基本方法.本文综述了液相色谱与不同质谱仪联用(三重四极杆、离子阱、四极杆-线性离子阱、高分辨质谱仪)检测反应性代谢产物的方法以及应用进展.

  6. Determination of red blood cell fatty acid profiles: Rapid and high-confident analysis by chemical ionization-gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Schober, Yvonne; Wahl, Hans Günther; Renz, Harald; Nockher, Wolfgang Andreas

    2017-01-01

    Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were <10% for all FA analyzed. Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory. Copyright © 2016. Published by Elsevier B.V.

  7. Identification of pancreas-specific proteins in endoscopically (endoscopic pancreatic function test) collected pancreatic fluid with liquid chromatography--tandem mass spectrometry.

    Science.gov (United States)

    Paulo, Joao A; Lee, Linda S; Wu, Bechien; Repas, Kathryn; Mortele, Koenraad J; Banks, Peter A; Steen, Hanno; Conwell, Darwin L

    2010-08-01

    We aimed to establish the endoscopic pancreatic function test (ePFT) as a method that can safely obtain pancreatic fluid for mass spectrometric analysis from patients during upper endoscopy and to reproducibly identify pancreas-specific proteins. We performed a sodium dodecyl sulfate-polyacrylamide gel electrophoresis and mass spectrometry-based proteomic analysis (in-gel tryptic digestion followed by liquid chromatography-tandem mass spectrometry [GeLC-MS/MS]) on ePFT-collected pancreatic fluid from 3 individuals, without evidence of chronic pancreatitis, who were undergoing an upper endoscopy for dyspepsia and chronic abdominal pain. Pancreatic fluid was safely collected from all subjects. The sodium dodecyl sulfate-polyacrylamide gel electrophoretic analysis of ePFT-collected pancreatic fluid revealed no significant variation (F statistic, 1.33, P = 0.29) in protein concentration during the 1-hour collection period and a visually reproducible protein banding pattern among the 3 subjects. The GeLC-MS/MS analysis of ePFT-collected fluid identified pancreas-specific proteins previously described from endoscopic retrograde cholangiopancreatography and surgical collection methods. Gene ontology further revealed that most of the proteins identified have a molecular function of proteases. The ePFT is capable of collecting large amounts of pancreatic fluid for proteomic analysis enabling the identification of pancreas-specific proteins. This endoscopic collection method coupled with GeLC-MS/MS is a powerful technique, which can be used in future investigations to elucidate pathways involved in the development and progression of pancreatic disease.

  8. Multi-residue determination of micropollutants in Phragmites australis from constructed wetlands using microwave assisted extraction and ultra-high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Petrie, Bruce; Smith, Benjamin D; Youdan, Jane; Barden, Ruth; Kasprzyk-Hordern, Barbara

    2017-03-22

    In constructed wetlands micropollutants can be removed from water by phytoremediation. However, micropollutant uptake and metabolism by plants here is poorly understood due to the lack of good analytical approaches. Reported herein is the first methodology developed and validated for the multi-residue determination of 81 micropollutants (pharmaceuticals, personal care products and illicit drugs) in the emergent macrophyte Phragmites australis. The method involved extraction by microwave accelerated extraction (MAE), clean-up using off-line solid phase extraction and analysis by ultra-high-performance liquid chromatography tandem mass spectrometry. Development of the MAE method found the influence of studied variables on micropollutant recovery to be: extraction temperature > sample mass > solvent composition. Validation of the developed extraction protocol revealed method recoveries were in the range 80-120% for the majority of micropollutants. Method quantitation limits (MQLs) were generally <5 ng g(-1) dry weight demonstrating the sensitivity of the methodology. Application of the method to P. australis from a constructed wetland used to treat trickling filter effluent found 17 micropollutants above their MQL, up to concentrations of 200 ng g(-1). Other than uptake, the presence of several metabolites (carbamazepine 10,11 epoxide, desvenlafaxine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, N-desmethyltramadol and norketamine) indicated metabolism within the plant may also occur. This new analytical methodology will enable a process mass balance of the constructed wetland to be attained for the first time, and thus help understand the role of phytoremediation in micropollutant removal by such systems.

  9. Degradation of fluoroquinolone antibiotics and identification of metabolites/transformation products by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Maia, Alexandra S; Ribeiro, Ana R; Amorim, Catarina L; Barreiro, Juliana C; Cass, Quezia B; Castro, Paula M L; Tiritan, Maria Elizabeth

    2014-03-14

    Antibiotics are a therapeutic class widely found in environmental matrices and extensively studied due to its persistence and implications for multi-resistant bacteria development. This work presents an integrated approach of analytical multi-techniques on assessing biodegradation of fluorinated antibiotics at a laboratory-scale microcosmos to follow removal and formation of intermediate compounds. Degradation of four fluoroquinolone antibiotics, namely Ofloxacin (OFL), Norfloxacin (NOR), Ciprofloxacin (CPF) and Moxifloxacin (MOX), at 10 mg L(-1) using a mixed bacterial culture, was assessed for 60 days. The assays were followed by a developed and validated analytical method of LC with fluorescence detection (LC-FD) using a Luna Pentafluorophenyl (2) 3 μm column. The validated method demonstrated good selectivity, linearity (r(2)>0.999), intra-day and inter-day precisions (RSD<2.74%) and accuracy. The quantification limits were 5 μg L(-1) for OFL, NOR and CPF and 20 μg L(-1) for MOX. The optimized conditions allowed picturing metabolites/transformation products formation and accumulation during the process, stating an incomplete mineralization, also shown by fluoride release. OFL and MOX presented the highest (98.3%) and the lowest (80.5%) extent of degradation after 19 days of assay, respectively. A representative number of samples was selected and analyzed by LC-MS/MS with triple quadrupole and the molecular formulas were confirmed by a quadruple time of flight analyzer (QqTOF). Most of the intermediates were already described as biodegradation and/or photodegradation products in different conditions; however unknown metabolites were also identified. The microbial consortium, even when exposed to high levels of FQ, presented high percentages of degradation, never reported before for these compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Simultaneous determination of amitraz, chlordimeform, formetanate and their main metabolites in human urine by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gao, Xue; Tan, Yanglan; Guo, Hao

    2017-03-11

    A rapid, simple and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of amitraz, chlordimeform, formetanate and their main metabolites, N-(2,4-dimethylphenyl)-N-methyl-formamidine (DMPF), 2,4-dimethylformamidine (DMF), 2,4-dimethylaniline (DMA), 4-chloro-2-methylaniline and 3-hydroxyacetanilide in human urine. The urine samples were mixed with buffer solutions (pH 8) and subsequently cleaned up by solid supported liquid/liquid extraction (SLE). The target analytes were efficiently separated with a Waters Atlantis T3 column (150mm×4.6mm, 5μm), ionized with electrospray ion source in positive mode, and quantitatively determined by tandem mass spectrometry in the multiple reaction monitoring (MRM) mode. In order to minimize matrix effects, the matrix-matched calibration curves of eight analytes were adopted with correlation coefficients (R(2)) above 0.99. The method were further validated by determining the limits of detection (LODs, 0.3-0.6ng/mL), the limits of quantitation (LOQs, 1.0-2.0ng/mL) and recoveries (89.1%-108.4%) with intra-day and inter-day relative standard deviation (RSD, <11%). The established method was applied and demonstrated in a real case by assaying a urine sample from a female poisoned by formetanate. The achieved results proved this method to be rapid, sensitive and accurate for simultaneous quantitation of eight analytes in human urine for intended forensic cases of human poisoning.

  11. [Determination of perfluorooctane sulfonates in fire-fighting foam and other materials by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Chen, Huiming; Cheng, Yan; Chen, Wei; Yu, Wenlian; Li, Xi; Wang, Zheng

    2010-02-01

    A novel method based on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed for the determination of perfluorooctane sulfonates (PFOS) in the fire-fighting foam, detergents and fabric finishing agents. The PFOS residue was extracted with water at first by ultrasonic, then separated by high-speed centrifugation. The supernatant was purified by pre-conditioned solid phase extraction (SPE) micro-column, and the extract was filtrated through a membrane with 0.2 microm diameter. The filtrated liquid was analyzed by HPLC using acetonitrile-10 mmol/L ammonium acetate solution (80 : 20, v/v) as mobile phase. The PFOS was detected by using negative electrospray ionization (ESI) on a tandem mass spectrometer in multiple reaction monitoring (MRM) mode. The qualitative analysis of the PFOS can be performed by using the relative abundance of two daughter ions of PFOS, and the quantitative analysis was performed by external standard method. The linear calibration curve was obtained in the range of 0.002 - 0.1 mg/L with a linear correlation coefficient (r2 ) of 0.998. The spiked recoveries for PFOS in the fire-fighting foam, detergents and fabric finishing agents were 93.4% - 103%, 93.2% - 102% and 91.8% - 102% with the relative standard deviation of 0.48% - 3.52%, 0.78% - 1.79% and 0.47% - 3.47%, respectively. And the detection limit for PFOS was 2 mg/kg (S/N > or = 10), which can meet the requirement for the PFOS restriction in fire-fighting foam, detergents and fabric finishing agents in the EU directives. With high accuracy and sensitivity, the method is simple and rapid, and can be used for PFOS inspection in fire-fighting foam, detergents and fabric finishing agents.

  12. An ultra-high-performance liquid chromatography-tandem mass spectrometric method for the determination of hederacoside C, a drug candidate for respiratory disorder, in rat plasma.

    Science.gov (United States)

    Rehman, Shaheed Ur; Choi, Min Sun; Kim, In Sook; Kim, Seung Hyun; Yoo, Hye Hyun

    2016-09-10

    Hederacoside C is a principal bioactive pharmaceutical ingredient of Hedera helix leaf extracts. H. helix extracts have long been used in folk medicine for the treatment of respiratory disorders. Currently, hederacoside C is investigated as a promising candidate for the treatment of respiratory diseases. In this study, an accurate, sensitive, rapid, and reliable bioanalytical method was developed for the determination of hederacoside C in rat plasma using ultra high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). For sample preparation, plasma proteins were precipitated with 0.1% acetic acid in acetonitrile. Waters UPLC BEH C18 (2.1mm I.D.×100mm, 1.7μm) column was used for chromatographic separation. A gradient elution of mobile phases consisting of 0.02% acetic acid in distilled water (solvent A) and 0.02% acetic acid in acetonitrile (solvent B) was used at a flow rate of 0.3mL/min. The multiple reaction monitoring (MRM) mode was used for mass spectrometric detection; the MRM transitions were m/z 1219.7→m/z 469.2 for hederacoside C and m/z 1108.3→m/z 221.2 for ginsenoside Rb1 (internal standard) in the negative ionization mode. A calibration curve was constructed in the range of 10-1000ng/mL. The intra- and inter-day precision and accuracy were within 5%. The developed UPLC-MS/MS method was successfully applied in a pharmacokinetic study of hederacoside C in rats. Hederacoside C was quickly but inadequately absorbed from the gastrointestinal tract of rats resulting in extremely low bioavailability and relatively slow clearance.

  13. Simultaneous determination of major type A and B trichothecenes, zearalenone and certain modified metabolites in Finnish cereal grains with a novel liquid chromatography-tandem mass spectrometric method.

    Science.gov (United States)

    Nathanail, Alexis V; Syvähuoko, Jenna; Malachová, Alexandra; Jestoi, Marika; Varga, Elisabeth; Michlmayr, Herbert; Adam, Gerhard; Sieviläinen, Elina; Berthiller, Franz; Peltonen, Kimmo

    2015-06-01

    A reliable and sensitive liquid chromatography-tandem mass spectrometric method was developed for the simultaneous quantitative determination in cereals of the Fusarium mycotoxins HT-2 toxin, T-2 toxin, deoxynivalenol, nivalenol and zearalenone, as well as the modified metabolites 3-acetyl-deoxynivalenol, α-zearalenol, β-zearalenol, deoxynivalenol-3-glucoside, HT-2-3-glucoside, nivalenol-3-glucoside, zearalenone-14-glucoside, zearalenone-14-sulphate, zearalenone-16-glucoside, α-zearalenol-14-glucoside and β-zearalenol-14-glucoside. The 'dilute and shoot' approach was used for sample preparation after extraction with acetonitrile:water:acetic acid (79:20:1, v/v/v). Separation was carried out using reversed-phase liquid chromatography, and detection was performed using tandem mass spectrometry in the selected reaction monitoring mode. The method was in-house validated according to performance characteristics, established in Commission Regulation EC No 401/2006 and Commission Decision EC No 657/2002, prior to its application in a nationwide survey for the analysis of barley, oat and wheat samples (n = 95) harvested in Finland during 2013. Deoxynivalenol and its glucosylated form were the most abundant of the analytes, being detected in 93 and 81 % of the samples, respectively. Concentrations of deoxynivalenol were unusually high in 2013, especially in oats, with some cases exceeding the maximum legislative limits for unprocessed oats placed on the market for first-stage processing. All modified mycotoxins analysed were detected, and the natural occurrence of some of these compounds (e.g. zearalenone-16-glucoside and nivalenol-3-glucoside) in barley, oats and/or wheat was documented for the first time.

  14. Development of a new ultra-high performance liquid chromatography - tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application

    Directory of Open Access Journals (Sweden)

    Vujović Maja M.

    2016-01-01

    Full Text Available Ambroxol hydrochloride is an expectorant agent, successfully applied in mucolytic therapy for acute and chronic bronchopulmonary diseases. The drug regulates not only mucus secretion but also showed antioxidant, anti-inflammatory and local anesthetic properties. To supplement the pharmacokinetic and toxicological studies of ambroxol, a rapid ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitation of ambroxol in rabbit serum was developed. A validation of the method was performed as per the ICH guidelines for the validation of bioanalytical methods. The chromatographic separation was achieved in a submicron Kinetex RP - C18 - column (2.1 mm x 50 mm, 1.3μm using the no buffer mobile phase. The ESI mass spectrometry in the MRM mode was used with a typical transitions m/z 378.9→263.8 for ambroxol and m/z 455.2→165.0 for IS. Linearity was determined with an average coefficient of determination >0.999 over the dynamic range from 0.5 - 200 ng/mL with LOD and LOQ of 0.25 ng/mL and 0.5 ng/mL, respectively. The results of the intra- and inter-day precision and accuracy determined in different days were all found to be within the acceptable limits ±15%. The present method was successfully applied to pharmacokinetic study in the rabbits after a single oral dose administration. [Projekat Ministarstva nauke Republike Srbije, br. 175045

  15. Quality by Design-Applied Liquid Chromatography-Tandem Mass Spectrometry Determination of Enzalutamide Anti-Prostate Cancer Therapy Drug in Spiked Plasma Samples.

    Science.gov (United States)

    Sankar, Ask; Palani, Shanmugasundaram; Velayudham, Ravichandiran

    2017-01-01

    This research article presents the Quality by Design (QbD)-finalised conditions for a method that uses liquid chromatography-tandem mass spectrometry for the determination of concentration of enzalutamide (ENZ), an atypical anticancer drug, in a drug formulation and in spiked plasma samples. Critical process attributes (CPA) considered to be the influential parameters in separation, identification, and quantification processes by ultrahigh-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry (UHPLC-ESI-MS/MS) were organic content, buffer strength, pH modifier, flow rate, spray voltage, sheath gas, and auxiliary gas that alter critical analytical attributes, such as retention time (R1) and area (R2). These factors were evaluated first in a factorial design (Taguchi orthogonal array design) and then extensively in a central composite design (CCD) to zero-in on the mobile phase for the quantification of ENZ standard drug and along with its internal standard (ENZIS) in spiked plasma samples and in formulation. Pareto chart from initial factorial design (Taguchi orthogonal array design) model suggested which of the CPA factors should be given the weightage, that is, to be exhaustively analysed in the CCD and response surface analysis. The elaborated parameters proposed by World Health Organization were studied by method validation, ie, selectivity, linearity, accuracy, precision repeatability system-suitability tests, method robustness/ruggedness, sensitivity, and stability. The strategy followed gives an insight on the development of a robust QbD-compliant quantitative UHPLC-ESI-MS/MS method for ENZ drug containing plasma samples (spiked).

  16. Quantitation of donepezil and its active metabolite 6-O-desmethyl donepezil in human plasma by a selective and sensitive liquid chromatography-tandem mass spectrometric method

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Bhavin N. [Chemistry Department, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380 009, Gujarat (India); Analytical Laboratory, BA Research India Ltd., Bodakdev, Ahmedabad 380 054, Gujarat (India); Sharma, Naveen [Analytical Laboratory, BA Research India Ltd., Bodakdev, Ahmedabad 380 054, Gujarat (India); Sanyal, Mallika [Chemistry Department, St. Xaviers' College, Navrangpura, Ahmedabad 380 009, Gujarat (India); Shrivastav, Pranav S. [Chemistry Department, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380 009, Gujarat (India)], E-mail: pranav_shrivastav@yahoo.com

    2008-11-23

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the simultaneous determination of donepezil (D) and its pharmacologically active metabolite, 6-O-desmethyl donepezil (6-ODD) in human plasma is developed using galantamine as internal standard (IS). The analytes and IS were extracted from 500 {mu}L aliquots of human plasma via solid-phase extraction (SPE) on Waters Oasis HLB cartridges. Chromatographic separation was achieved in a run time of 6.0 min on a Waters Novapak C18 (150 mm x 3.9 mm, 4 {mu}m) column under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for D, 6-ODD and IS were at m/z 380.1 {yields} 91.2, 366.3 {yields} 91.3 and 288.2 {yields} 213.2, respectively. The method was fully validated for its selectivity, interference check, sensitivity, linearity, precision and accuracy, recovery, matrix effect, ion suppression/enhancement, cross-specificity, stability and dilution integrity. A linear dynamic range of 0.10-50.0 ng mL{sup -1} for D and 0.02-10.0 ng mL{sup -1} for 6-ODD was evaluated with mean correlation coefficient (r) of 0.9975 and 0.9985, respectively. The intra-batch and inter-batch precision (%CV, coefficient of variation) across five quality control levels was less than 7.5% for both the analytes. The method was successfully applied to a bioequivalence study of 10 mg donepezil tablet formulation in 24 healthy Indian male subjects under fasting condition.

  17. Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assays.

    Science.gov (United States)

    Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J

    2014-07-01

    Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.

  18. Studies on the interactions between ginsenosides and liposome by equilibrium dialysis combined with ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hou, Guangyue; Niu, Jun; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2013-04-01

    To study the interactions between components of Panax Ginseng and liposome biomembrane, we applied the equilibrium dialysis system combined with ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) approach to analyze and identify the bioactive components of ginseng. Moreover, the effect of pH value has also been investigated on their interactions between the ginsenosides of ginseng extract and biomembrane. The result shows that seven kinds of ginsenosides have obvious interactions with biomembrane in comparison with the standards in terms of tandem mass spectrometry (MS/MS) data along with retention time, including four panaxadiol ginsenosides (Rb1, Rb2, Rc, Rd) and three panaxatriol ginsenosides (Re, Rf, Rg2). The value of binding degree decreased with the increase of molecular weight. The sugar moieties which are attached to C-20 were the main factor affecting the binding degree of panaxadiol ginsenosides. The interactions between panaxadiol ginsenosides and biomembrane correlate to the type and number of sugar moieties in ginsenosides. The sugar moieties which are at C-6 and C-20 have been shown to influence the value of binding degree for panaxatriol ginsenosides. In addition, the pH value has been shown to have an impact on the interactions. Overall, ginsenoside Rd has a better absorption character among the seven ginsenosides. In the study, we have screened the potential bioactive components of ginseng in vitro using the equilibrium dialysis-UPLC-MS/MS method, and then predicted the potential bioactivities of ginseng, which contribute to the investigation of the efficacy of ginseng. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Bunker, Ashley; Rockwood, Alan L; Meikle, A Wayne

    2012-06-14

    Measurement of free estradiol offers a better representation of the bioactive fraction of the hormone. We describe a direct equilibrium dialysis-liquid chromatography-tandem mass spectrometry (ED-LC-MS/MS) method for serum free estradiol. Two hundred fifty microliter aliquots of serum were dialyzed for 22h followed by liquid-liquid extraction and derivatization with dansyl chloride. Free estradiol was measured using LC-MS/MS with an AB SCIEX 5500 mass spectrometer in positive ion and multiple reaction monitoring (MRM) mode. The limits of detection and quantification for free estradiol were 0.25 and 0.5pg/ml (0.9 and 1.8pmol/l) respectively. Total imprecision was less than 10%. Results of method comparison showed 3 times overestimation using indirect methods of measurement. Reference intervals in pre-menopausal women in follicular, mid-cycle, and luteal phases of cycle were <2.4, <3.1 and <2.6pg/ml (8.8, 11.4, 9.5pmol/l) respectively; in post menopausal women the concentrations were ≤0.5pg/ml (1.8pmol/l). ED-LC-MS/MS is a direct method for accurately measuring free estradiol, independent of total estradiol or sex hormone binding globulin concentrations. Imprecision and sensitivity of the method are adequate for clinical diagnostic applications. The degree of variation observed in the method comparison reinforces the relevance of method specific reference ranges. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Determination of pazopanib (GW-786034) in mouse plasma and brain tissue by liquid chromatography-tandem mass spectrometry (LC/MS-MS)

    Science.gov (United States)

    Minocha, Mukul; Khurana, Varun; Mitra, Ashim K

    2012-01-01

    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LC/MS-MS) method has been developed and validated for the quantitative determination of pazopanib in mouse plasma and brain tissue homogenate. Single liquid-liquid extraction step with ethyl acetate was employed for analysis of pazopanib and the internal standard (IS); vandetanib. HPLC separation was performed on an XTerra® MS C18 column 50 × 4.6mm, 5.0 μm. The mobile phase consisted of 70% acetonitrile and 30% water with 0.1% formic acid, pumped at a flow rate of 0.25 ml/min. Analysis time was 3.5 min per run and both the analyte and IS eluted within 1.8–2.0 minutes. Multiple reactions monitoring (MRM) mode was utilized to detect the compounds of interest. The mass spectrometer was operated in the positive ion mode for detection. The precursor to product ions (Q1 Q3) selected for pazopanib and internal standard during quantitative optimization were (m/z) 438.1 357.2 and 475.0 112.2 respectively. The calibration curves were linear over the range of 3.9–1000ng/ml in both biological matrices. Lower limit of quantification (LLOQ) for mouse plasma and brain tissue was 3.9ng/ml. The values for inter and intra day precision and accuracy were well within the ranges acceptable for analytical assessment (<15%). This method was applied to determine brain to plasma concentration ratio and relevant pharmacokinetic parameters of pazopanib after a single intravenous dose of 5mg/kg in FVB wild type mice. PMID:22749591

  1. Polydopamine-coated magnetic nanoparticles for isolation and enrichment of estrogenic compounds from surface water samples followed by liquid chromatography-tandem mass spectrometry determination.

    Science.gov (United States)

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2016-06-01

    Estrogens, phytoestrogens, and mycoestrogens may enter into the surface waters from different sources, such as effluents of municipal wastewater treatment plants, industrial plants, and animal farms and runoff from agricultural areas. In this work, a multiresidue analytical method for the determination of 17 natural estrogenic compounds, including four steroid estrogens, six mycoestrogens, and seven phytoestrogens, in river water samples has been developed. (Fe3O4)-based magnetic nanoparticles coated by polydopamine (Fe3O4@pDA) were used for dispersive solid-phase extraction, and the final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The Fe3O4 magnetic nanoparticles were prepared by a co-precipitation procedure, coated by pDA, and characterized by scanning electron microscopy, infrared spectroscopy, and elemental analysis. The sample preparation method was optimized in terms of extraction recovery, matrix effect, selectivity, trueness, precision, method limits of detection, and method limits of quantification (MLOQs). For all the 17 analytes, recoveries were >70 % and matrix effects were below 30 % when 25 mL of river water sample was treated with 90 mg of Fe3O4@pDA nanoparticles. Selectivity was tested by spiking river water samples with 50 other compounds (mycotoxins, antibacterials, conjugated hormones, UV filters, alkylphenols, etc.), and only aflatoxins and some benzophenones showed recoveries >60 %. This method proved to be simple and robust and allowed the determination of natural estrogenic compounds belonging to different classes in surface waters with MLOQs ranging between 0.003 and 0.1 μg L(-1). Graphical Abstract Determination of natural estrogenic compounds in water by magnetic solid phase extraction followed by liquid chromatography-tandem mass spectrometry analysis.

  2. Study on the determination and chiral inversion of R-salbutamol in human plasma and urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Ting; Zeng, Jing; Liu, Shan; Zhao, Ting; Wu, Jie; Lai, Wenshi; He, Mingzhi; Xu, Beining; Qu, Shanshan; Xu, Ling; Tan, Wen

    2015-10-01

    The chiral inversion has been a concerned issue during the research and development of a chiral drug. In this study, a sensitive chiral liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for determination of salbutamol enantiomers in human plasma and urine. The chiral inversion mechanism of R-salbutamol was fully investigated for the first time by studying the effects of physicochemical factors, including pH, temperature and time. A fitted model to predict the chiral inversion ratio of R-salbutamol was proposed using a Box-Behnken design. All the samples were separated on an Astec Chirobiotic T column and detected by a tandem mass spectrometer in multiple reaction monitoring mode. Lower limit of quantification of 0.100ng/mL was achieved under the optimized conditions. The method was fully validated and successfully applied to the clinical pharmacokinetic study of R-salbutamol in healthy volunteers. Chiral inversion of R-salbutamol to S-salbutamol has been detected in urine samples. The results indicated that pH and temperature were two dominant factors that caused the chiral inversion of R-salbutamol, which should be taken into consideration during the analysis of chiral drugs. The chiral inversion of R-salbutamol determined in this study was confirmed resulted from the gastric acid in stomach rather than caused by the analysis conditions. Moreover, the calculated results of the fitted model matched very well with the enantioselective pharmacokinetic study of R-salbutamol, and the individual difference of the chiral inversion ratio of R-salbutamol was related to the individual gastric environment. On the basis of the results, this study provides important and concrete information not only for the chiral analysis but also for the metabolism research of chiral drugs.

  3. Rapid determination of six carcinogenic primary aromatic amines in mainstream cigarette smoke by two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun

    2017-01-27

    A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Hung-Ju Chen

    2011-12-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method (LC-MS/MS was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (± naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals.

  5. Ultra-high-pressure liquid chromatography tandem mass spectrometry determination of hallucinogenic drugs in hair of psychedelic plants and mushrooms consumers.

    Science.gov (United States)

    Pichini, Simona; Marchei, Emilia; García-Algar, Oscar; Gomez, Arelis; Di Giovannandrea, Rita; Pacifici, Roberta

    2014-11-01

    A procedure based on ultra-high-pressure liquid chromatography tandem mass spectrometry has been developed for the determination of mescaline, N,N-dimethyltryptamine, psilocin, psilocybin, salvinorin A in hair of consumers of psychedelic vegetal material such peyote or trichocereus cacti, psilocybe mushrooms, Salvia divinorum or psychedelic beverage ayahuasca. After hair washing with methyl alcohol and diethyl ether and subsequent addition of mescaline-d9 and 3,4-methylenedioxypropylamphetamine as internal standards, hair samples were treated with 250μl VMA-T M3 reagent for 1h at 100°C. After cooling, 100μl M3 extract were diluted with 400μl water and a volume of 10μl was injected into chromatographic system. Chromatographic separation was achieved at ambient temperature using a reverse-phase column and a linear gradient elution with two solvents: 0.3% formic acid in acetonitrile and 5mM ammonium formate pH 3. The mass spectrometer was operated in positive ion mode, using multiple reaction monitoring via positive electrospray ionization. The method was linear from the limit of quantification (0.03-0.05ng/mg depending on analyte under investigation) to 10ng/mg hair, with an intra- and inter-assay imprecision and inaccuracy always less than 15% and an analytical recovery between 79.6% and 97.4%, depending on the considered analyte. Using the validated method, mescaline was found in concentration range of 0.08-0.13ng/mg in hair of peyote smokers, 3.2ng salvinorin A per mg hair were determined in hair from a S. divinorum smoker, 5.6ng N,N-dimethyltryptamine per mg hair from an ayahuasca user and finally 0.8ng psilocybin per ng hair of a psilocybe consumer.

  6. [Simultaneous determination of glyphosate and glufosinate-ammonium residues in tea by ultra performance liquid chromatography-tandem mass spectrometry coupled with pre-column derivatization].

    Science.gov (United States)

    Wu, Xiaogang; Chen, Xiaoquan; Xiao, Haijun; Liu, Binqiu

    2015-10-01

    A method was developed for the determination of glyphosate (GLY) and glufosinate-ammonium (GLUF) in tea using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted with ultrapure water and dichloromethane for 30 min under ultrasonication, followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and GLUF were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer for 2 h. The derivatives of GLY and GLUF were separated on a Waters C18 column (50 mm x 2.1 mm, 1.7 μm) in a gradient elution mode, and finally detected with positive electrospray ionization-mass spectrometry (ESI-MS/MS ) in multiple reaction monitoring (MRM) mode. The quantification analysis was performed by external standard method. The method showed a good linearity (r > 0. 990) in the range of 0.003 125-0.1 mg/L. The limits of detection (LODs) of GLY and GLUF were 0.03 mg/kg. At the spiked levels of 0.375, 1.5 and 4.5 mg/kg, the recoveries of GLY and GLUF were 87.37%-99.11% and 81.44% -86.17% respectively, and the relative standard deviations (RSDs) (n = 6) of GLY and GLUF were 0.68%-1.35% and 1.01%-2.33%, respectively. This method is simple, rapid and characterized with acceptable sensitivity and accuracy to meet the requirements for the analysis of GLY and GLUF simultaneously in tea.

  7. Ultra-high-pressure liquid chromatography tandem mass spectrometry determination of antidepressant and anxiolytic drugs in neonatal meconium and maternal hair.

    Science.gov (United States)

    Pichini, Simona; Cortes, Laura; Marchei, Emilia; Solimini, Renata; Pacifici, Roberta; Gomez-Roig, Maria Dolores; García-Algar, Oscar

    2016-01-25

    A procedure based on ultra-high-pressure liquid chromatography tandem mass spectrometry has been developed for the determination of 22 antidepressant and anxiolytic drugs ad metabolites in the three consecutive maternal hair segments representing the pregnancy trimesters and paired neonatal meconium samples. After hair washing with methyl alcohol and diethyl ether and subsequent addition of internal standards, hair samples were treated with 500 μl VMA-T M3 reagent for 1h at 100 °C. After cooling, 100 μl M3 extract were diluted with 400 μl water and a volume of 10 μl was injected into chromatographic system. Meconium samples were firstly treated with 1 ml methyl alcohol and the organic layer back-extracted twice with 1.5 ml of a mixture of ethylacetate:hexane (80:20, v/v). Chromatographic separation was achieved at ambient temperature using a reverse-phase column and a linear gradient elution with two solvents: 0.3% formic acid in acetonitrile and 5mM ammonium formate pH 3. The mass spectrometer was operated in positive ion mode, using multiple reaction monitoring via positive electrospray ionization. The method was linear from the limit of quantification (0.05-1 ng/mg hair and 5-25 ng/g meconium depending on analyte under investigation;) to 10 ng/mg hair and 1000 ng/g meconium, with an intra- and inter-assay imprecision and inaccuracy always less than 20% and an analytical recovery between 66.6% and 95.3%, depending on the considered analyte and biological matrix. Using the validated method, 7 mothers were found positive to one or more hair segments and 5 meconium samples were found positive to one or more antidepressant and anxiolytic drugs, assessing prenatal exposure to these drugs following maternal consumption in one or more pregnancy trimesters.

  8. Direct large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry determination of artificial sweeteners sucralose and acesulfame in well water.

    Science.gov (United States)

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Hrudey, Steve E; Le, X Chris; Li, Xing-Fang

    2014-09-12

    Acesulfame (ACE) and sucralose (SUC) have become recognized as ideal domestic wastewater contamination indicators. Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis is commonly used; however, the sensitivity of SUC is more than two orders of magnitude lower than that of ACE, limiting the routine monitoring of SUC. To address this issue, we examined the ESI behavior of both ACE and SUC under various conditions. ACE is ionic in aqueous solution and efficiently produces simple [M-H](-) ions, but SUC produces multiple adduct ions, limiting its sensitivity. The formic acid (FA) adducts of SUC [M+HCOO](-) are sensitively and reproducibly generated under the LC-MS conditions. When [M+HCOO](-) is used as the precursor ion for SUC detection, the sensitivity increases approximately 20-fold compared to when [M-H](-) is the precursor ion. To further improve the limit of detection (LOD), we integrated the large volume injection approach (500μL injection) with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which reduced the method detection limit (MDL) to 0.2ng/L for ACE and 5ng/L for SUC. To demonstrate the applicability of this method, we analyzed 100 well water samples collected in Alberta. ACE was detected in 24 wells at concentrations of 1-1534ng/L and SUC in 8 wells at concentrations of 65-541ng/L. These results suggest that wastewater is the most likely source of ACE and SUC impacts in these wells, suggesting the need for monitoring the quality of domestic well water.

  9. Development of a Supercritical Fluid Chromatography-Tandem Mass Spectrometry Method for the Determination of Azacitidine in Rat Plasma and Its Application to a Bioavailability Study

    Directory of Open Access Journals (Sweden)

    Dongpo Li

    2013-12-01

    Full Text Available Azacitidine is widely used for the treatment of myelodysplastic syndromes (MDS and acute myelogenous leukaemia (AML. The analysis of azacitidine in biological samples is subject to interference by endogenous compounds. Previously reported high-performance liquid chromatography/tandem mass spectrometric (HPLC-MS/MS bioanalytical assays for azacitidine suffer from expensive sample preparation procedures or from long separation times to achieve the required selectivity. Herein, supercritical fluid chromatography with tandem mass spectrometry (SFC-MS/MS was explored as a more promising technique for the selective analysis of structure-like or chiral drugs in biological matrices. In this study, a simple, rapid and specific SFC/MS/MS analytical method was developed for the determination of azacitidine levels in rat plasma. Azacitidine was completely separated from the endogenous compounds on an ACQUITY UPLC™ BEH C18 column (100 mm × 3.0 mm, 1.7 μm; Waters Corp., Milford, MA, USA using isocratic elution with CO2/methanol as the mobile phase. The single-run analysis time was as short as 3.5 min. The sample preparation for protein removal was accomplished using a simple methanol precipitation method. The lower limit of quantification (LLOQ of azacitidine was 20 ng/mL. The intra-day and inter-day precisions were less than 15%, and the relative error (RE was within ±15% for the medium- and high-concentration quality control (QC samples and within ±20% for the low-concentration QC samples. Finally, the developed method was successfully applied to a pharmacokinetic study in rats following the intravenous administration of azacitidine.

  10. Exploring matrix effects in liquid chromatography-tandem mass spectrometry determination of pesticide residues in tropical fruits.

    Science.gov (United States)

    Botero-Coy, Ana María; Marín, José M; Serrano, Roque; Sancho, Juan Vicente; Hernández, Félix

    2015-05-01

    Tropical fruits are being increasingly consumed around the world because of their appreciated characteristics, particularly their high nutritional value and distinctive taste, which are different from those of traditional fruits. Owing to their introduction into international markets it is necessary to have a reliable analytical methodology available for the sensitive determination of pesticide residues in order to monitor the compliance of maximum residue limits (MRLs). From an analytical point of view, tropical fruits have generally been far less studied than other fruits frequently consumed in the European Union or USA, which are among the most important markets. In this work, LC-MS/MS-based methodology using a triple quadrupole analyzer was developed for the multi-residue determination of selected pesticides and metabolites in tropical fruits, which were selected among the most popular in Colombia, one of the most important suppliers of tropical fruits around the world. After selection of a QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe)-based sample treatment, the study focused on the evaluation of matrix effects, in order to find a simple way for their correction. Twelve different food matrices were selected to perform this study: the seven Colombian tropical fruits of highest value for domestic and international markets (uchuva, tamarillo, granadilla, gulupa, maracuya, papaya, and pithaya), and five more matrices highly consumed in Colombia (lulo, carambolo, feijoa, mangostan, and guayaba). Twenty compounds, including pesticides widely applied in tropical fruits pest control and several metabolites considered in residue definition, were used as model compounds in this work. Correction factors were used on the basis of calibration graphs obtained with standards in solvent and in matrix, and their usefulness was supported by validation of the method in all the matrices tested at 0.01 and 0.1 mg/kg. The analysis of real-world samples revealed the

  11. Discrimination of eight chloramphenicol isomers by liquid chromatography tandem mass spectrometry in order to investigate the natural occurence of chloramphenicol

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Zuidema, T.; Jong, de J.; Stolker, A.A.M.; Nielen, M.W.F.

    2011-01-01

    This paper describes the discrimination of eight different isomers of chloramphenicol (CAP), an antibiotic banned for use in food producing animals, by reversed phase and chiral liquid chromatography in combination with tandem mass spectrometric detection. Previously, by liquid chromatography couple

  12. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  13. Simultaneous determination of pirfenidone and its metabolite in human plasma by liquid chromatography-tandem mass spectrometry: application to a pharmacokinetic study.

    Science.gov (United States)

    Wen, Yu-Guan; Liu, Xia; He, Xiu-Ling; Shang, De-Wei; Ni, Xiao-Jia; Zhang, Ming; Wang, Zhan-Zhang; Hu, Jin-Qing; Qiu, Chang

    2014-01-01

    A simple and rapid analytical method for the simultaneous determination of pirfenidone and its metabolite, 5-carboxy-pirfenidone, in human plasma using liquid chromatography-tandem mass spectrometry has been developed and validated. Aliquots of plasma (0.1 mL) containing pirfenidone and 5-carboxy-pirfenidone, as well as deuterium-labeled internal standards (ISs), were deproteinized using acetonitrile. An Agilent Zorbax Plus C18 column was used for the chromatography, with isocratic elution. The mobile phase was a mixture of acetonitrile and aqueous ammonium formate solution (5 mM) containing 0.1% formic acid (60 : 40, v/v). Using multiple reaction monitoring in positive ionization mode, transitions m/z 186.1 → 65.1, m/z 216.0 → 77.0, m/z 191.1 → 65.1 and m/z 221.0 → 81.0 were chosen to quantify pirfenidone, 5-carboxy-pirfenidone and the two ISs, respect