WorldWideScience

Sample records for chromatography-mass spectrometry analysis

  1. Liquid chromatography mass spectrometry for analysis of microbial metabolites

    DEFF Research Database (Denmark)

    Klitgaard, Andreas

    Filamentous fungi serve a very important role in Nature where they break down organic matter, releasing nutrients that can be used by other organisms. Fungi and other microorganisms also produce a wide array of bioactive compounds, the secondary metabolites( SMs), used for such diverse roles....... Classical methods for manual interpretation of one single data file at a time are not sufficient to cope with this influx of data. Hence, there is a need for development of new methods for data analysis to extract valuable information in the data, and also speeding up the data analysis itself. A prime goal...

  2. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  3. Gas chromatography-mass spectrometry analysis of various organic extracts ofMerremia borneensisfrom Sabah

    Institute of Scientific and Technical Information of China (English)

    M Amzad Hossain; Muhammad Dawood Shah; Mahyar Sakari

    2011-01-01

    Objective:To analyse the chemical composition of different extracts ofMerremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).Methods: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts ofM. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol. Results: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further theM. borneensisleaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.Conclusions: The suitable extracts for respective compounds can be chosen on the basis of aboveGC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extractsM. borneensis might have some ecological significance.

  4. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids

  5. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel; Borek, Theodore Thaddeus, III

    2010-09-01

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief

  6. ANALYSIS OF TRACE-LEVEL ORGANIC COMBUSTION PROCESS EMISSIONS USING NOVEL MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY PROCEDURES

    Science.gov (United States)

    The paper discusses the analysis of trace-level organic combustion process emissions using novel multidimensional gas chromatography-mass spectrometry (MDGC-MS) procedures. It outlines the application of the technique through the analyses of various incinerator effluent and produ...

  7. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  8. Surface-sampling and analysis of TATP by swabbing and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Romolo, Francesco Saverio; Cassioli, Luigi; Grossi, Silvana; Cinelli, Giuseppe; Russo, Mario Vincenzo

    2013-01-10

    The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm(®) M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.

  9. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R.; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  10. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  11. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Stepanov, Irina; Villalta, Peter W; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified eight different polycyclic aromatic hydrocarbons (PAHs) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAHs in smokeless tobacco after a simple two-step extraction and purification procedure. The method produced coefficients of variation under 10% for most PAHs. The limits of quantitation for different PAHs varied between 0.3 and 11 ng/g tobacco, starting with a 300 mg sample. The recovery of the stable isotope-labeled internal standards averaged 87%. The method was applied to analysis of 23 moist snuff samples that included various flavors of the most popular U.S. moist snuff brands, as well as 17 samples representing the currently marketed brands of spit-free tobacco pouches, a relatively new type of smokeless tobacco. The sum of all detected PAHs in conventional moist snuff averaged 11.6 (+/-3.7) microg/g dry weight; 20% of this amount was comprised of carcinogenic PAHs. The levels of PAHs in new spit-free tobacco products were much lower than those in moist snuff; the sum of all detected PAHs averaged 1.3 (+/-0.28) microg/g dry weight. Our findings render PAHs one of the most prevalent groups of carcinogens in smokeless tobacco. Urgent measures are required from the U.S. tobacco industry to modify manufacturing processes so that the levels of these toxicants and carcinogens in U.S. moist snuff are greatly reduced.

  12. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate

    Science.gov (United States)

    Lee, E.A.; Zimmerman, L.R.; Bhullar, B.S.; Thurman, E.M.

    2002-01-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solidphase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 ??g/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 ??g/L, relative standard deviation ??15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'ELISA gave a false positive rate of 18% between 0.1 and 1.0 ??g/L and a false positive rate of only 1% above 1.0 ??g/L. The relative standard deviation was ??20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  13. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate.

    Science.gov (United States)

    Lee, E A; Zimmerman, L R; Bhullar, B S; Thurman, E M

    2002-10-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solid-phase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 microg/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 microg/ L, relative standard deviation +/- 15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'EUSA gave a false positive rate of 18% between 0.1 and 1.0 microg/L and a false positive rate of only 1% above 1.0 microg/L The relative standard deviation was +/- 20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  14. Application Of Dexamethasone Analysis Procedure In Pharmaceutical Product And Food Samples By Using The Liquid Chromatography Mass Spectrometry (LC-MS)

    International Nuclear Information System (INIS)

    The high pressure liquid chromatography mass spectrometry method for determination of dexamethasone has been studied. The authors have some results in found the optimal conditions in high pressure liquid chromatography mass spectrometry system for applications analysis of dexamethasone such as flow rate 0.5 ml/minute, the rate of mobile phase ACN: 0.1% HCOOH (80:20), injection volume was 20 μl. Besides, the authors analyzed a number of experimental samples with recovery range 84-96%. These initial results give the high pressure liquid chromatography mass spectrometry in operation. (author)

  15. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul Haque; Rahima Khatun; Zahira Yaakob

    2015-01-01

    Objective: To evaluate the antibacterial activity of essential oil from Trigonella foenum-graecum seeds powder, and identify the compounds from the extracted oil. Methods: The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor. Seven strains of bacteria were used to test antibacterial activity of the extract. The activity against bacteria was tested by disk diffusion method using Whatman No. 1 filter paper. Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector. Results: The hydrodistillation of seeds powder yielded 0.285%(v/w) of oil. Disk diffu-sion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains. The inhibition zone ranged from (8 ± 0) mm to (15.0 ± 0.7) mm depending on microbial strains. Gas chromatography mass spectrometry analysis showed 14 different compounds. The total compounds represented 80.96%of the oil. Conclusions: The antibacterial activity is due to the effects of different biological active compounds present in the extract. Identification of the compounds may help to develop new effective antimicrobial agent(s). Further researches on purification, characterization and toxicology of the active compounds are needed.

  16. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul; Haque; Rahima; Khatun; Zahira; Yaakob

    2015-01-01

    Objective:To evaluate the antibacterial activity of essential oil from Trigonella foenumgraecum seeds powder,and identify the compounds from the extracted oil.Methods:The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor.Seven strains of bacteria were used to test antibacterial activity of the extract.The activity against bacteria was tested by disk diffusion method using Whatman No.1filter paper.Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector.Results:The hydrodistillation of seeds powder yielded 0.285%(v/w)of oil.Disk diffusion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains.The inhibition zone ranged from(8±0)mm to(15.0±0.7)mm depending on microbial strains.Gas chromatography mass spectrometry analysis showed14 different compounds.The total compounds represented 80.96%of the oil.Conclusions:The antibacterial activity is due to the effects of different biological active compounds present in the extract.Identification of the compounds may help to develop new effective antimicrobial agent(s).Further researches on purification,characterization and toxicology of the active compounds are needed.

  17. Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Beach, Daniel G; Melanson, Jeremy E; Purves, Randy W

    2015-03-01

    The analysis of paralytic shellfish toxins (PSTs) by liquid chromatography-mass spectrometry remains a challenge because of their high polarity, large number of analogues and the complex matrix in which they occur. Here we investigate the potential utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) as a gas-phase ion separation tool for analysis of PSTs by mass spectrometry. We investigate the separation of PSTs using FAIMS with two divergent goals: using FAIMS as a primary separation tool for rapid screening by electrospray ionization (ESI)-FAIMS-MS or combined with LC in a multidimensional LC-ESI-FAIMS-MS separation. First, a survey of the parameters that affect the sensitivity and selectivity of PST analysis by FAIMS was carried out using ESI-FAIMS-MS. In particular, the use of acetonitrile as a gas additive in the carrier gas flow offered good separation of all PST epimeric pairs. A second set of FAIMS conditions was also identified, which focussed PSTs to a relatively narrow CV range allowing development of an LC-ESI-FAIMS-MS method for analysis of PST toxins in complex mussel tissue extracts. The quantitative capabilities of this method were evaluated by analysing a PST containing mussel tissue matrix material. Results compared favourably with analysis by an established LC-post-column oxidation-fluorescence method with recoveries ranging from 70 to 106%, although sensitivity was somewhat reduced. The current work represents the first successful separation of PST isomers using ion mobility and shows the promise of FAIMS as a tool for analysis of algal biotoxins in complex samples and outlines some critical requirements for its future improvement.

  18. Analysis of psilocybin and psilocin in Psilocybe subcubensis Guzmán by ion mobility spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W

    1999-01-11

    A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.

  19. ANALYSIS OF CHEMICAL COMPOUNDS OF AGARWOOD OIL FROM DIFFERENT SPECIES BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GCMS

    Directory of Open Access Journals (Sweden)

    Yumi Zuhanis Has-Yun Hashim

    2014-05-01

    Full Text Available ABSTRACT: Agarwood oil is a highly prized type of oil due to its unique aroma. The oil is extracted from the fragrant resin found in the agarwood tree (trunk.  The unique aroma and quality of agarwood resin and oil are contributed by the presence of certain chemical compounds. In this work, analysis and comparison of the chemical compounds of agarwood oil from A. malaccensis, A. sub-integra and a mixture of both were conducted.  The essential oils were diluted in hexane (5% prior to gas chromatography mass spectrometry (GCMS analysis performed using Agilent GCMS 7890A coupled with MSD quadrupole detector 5975 C.  Separation of analytes by gas chromatography was carried out using a Hewlett Packard HP-5MS silica capillary column (30 m X 0.25 mm X 0.25 mm. A total of 107 compounds were identified from the three samples of agarwood oils. Fifty-five (55 components were identified in A. malaccensis sample which contributes to the largest portion of the total compounds. About 20% of the compounds identified were aromatic and sesquiterpenes which have been revealed to be the main active compounds of agarwood oils which also give the aroma and pleasant odour of agarwood. Different compositions or profile of chemical components were found in agarwood oils from the two different species. Two compounds were commonly identified in all three samples namely 3-phenyl-2-butanone and alpha-cubebene.  Further studies are needed to refine the results which later can be used to assist detection and authentication of agarwood as well as its scientific-based grading. ABSTRAK: Minyak gaharu merupakan sejenis minyak beraroma unik yang mendapat permintaan tinggi dan mahal. Minyak ini diekstrak daripada resin beraroma yang terbentuk di dalam batang pokok gaharu. Keunikan aroma dan kualiti resin dan minyak gaharu ini bergantung kepada kehadiran bahan kimia tertentu. Penyelidikan ini menjurus kepada analisis dan perbandingan bahan-bahan kimia yang terdapat dalam minyak

  20. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults.

  1. The analysis of common metabolites of organophosphorus pesticides in urine by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2:1:10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 μg/ml in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants

  2. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  3. Analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Ramírez-Maya, Erika; Alvarado-Suárez, Luís Angel

    2009-04-01

    A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography-mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109-1.323 microg/mL for capsaicin and 0.107-1.713 microg/mL for dihydrocapsaicin with correlation coefficient up to r=0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0-25 459 microg/g) and dihydrocapsaicin (93-1 130 microg/g) was found in the pepper and pepper sauces samples (4.3-717.3 and 1.0-134.8 microg/g), respectively.

  4. Direct analysis of volatile fatty acids in marine sediment porewater by two-dimensional ion chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Glombitza, Clemens; Pedersen, Jeanette; Røy, Hans;

    2014-01-01

    by two-dimensional ion chromatography-mass spectrometry (2D IC-MS). The first chromatographic dimension is used to separate the VFAs from the inorganic ions whereas the second dimension separates the individual VFAs. Quantification and identification are achieved by online mass spectrometry in selected...

  5. Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuan-fan YANG; Shen-ru CHEN; Hui NI; Xing-qian YE

    2008-01-01

    Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl ace tate extraction fol-lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods.

  6. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing additi

  7. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  8. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From t

  9. Direct analysis of intact glycidyl fatty acid esters in edible oils using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    H. van Steenbergen; K. Hrnčiřík; A. Ermacora; S. de Koning; H.-G. Janssen

    2013-01-01

    Glycidyl esters (GE), fatty acid esters of glycidol, are process contaminants formed during edible oil processing. A novel direct method for the determination of intact GE in oils and fats based on gas chromatography-mass spectrometry (GC-MS) is presented. The method consists of a simple extraction

  10. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    Science.gov (United States)

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  11. Carbohydrate analysis of hemicelluloses by gas chromatography-mass spectrometry of acteylated methyl glycosides

    DEFF Research Database (Denmark)

    Sárossy, Zsuzsa; Plackett, David; Egsgaard, Helge

    2012-01-01

    A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C-labele......-labeled analogues were used for identification and quantitative analysis. Excellent chromatographic separation of the monosaccharide derivatives was found and identification of the anomeric configuration was feasible through a prepared and identified pure methyl 2,3,4,6-tetra......A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C...

  12. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yong-Gang Xia

    2014-01-01

    Full Text Available This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS. The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method.

  13. Derivatisation/solid-phase microextraction followed by gas chromatography-mass spectrometry for the analysis of phenoxy acid herbicides in aqueous samples

    DEFF Research Database (Denmark)

    Nilsson, Torben; Baglio, Daniela; Galdo-Miguez, Isabel;

    1998-01-01

    Different combinations of derivatisation and solid-phase microextraction followed by gas chromatography-mass spectrometry were optimised and evaluated for the analysis of phenoxy acid herbicides in water. The most successful derivatisation approach was aqueous-phase derivatisation with benzyl...

  14. Analysis of swainsonine and swainsonine N-oxide as trimethylsilyl derivatives by Liquid Chromatography-Mass Spectrometry and their relative occurrence in plants toxic to livestock

    Science.gov (United States)

    A liquid chromatography-mass spectrometry method was developed for the analysis of the indolizidine alkaloid swainsonine and its N-oxide. The method is based on a one step solvent partitioning extraction procedure followed by trimethylsilylation of the dried extract and subsequent detection and qua...

  15. Analysis of 5-hydroxymethylfurfural in foods by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Teixidó, E; Santos, F J; Puignou, L; Galceran, M T

    2006-11-24

    A new, simple and selective method for the analysis of 5-hydroxymethylfurfural (HMF) in foods by gas chromatography coupled to mass spectrometry (GC-MS) is proposed. Several derivatising procedures based on the formation of an HMF silylated derivative using different reagents were studied. Among the derivatising reagents examined, N,O-bis-trimethylsilyltrifluoroacetamide (BSTFA) provided the best derivatisation yield. Sample clean-up was also optimised, using either liquid-liquid extraction with dichloromethane or solid-phase extraction (SPE) with several commercially available cartridges, and the best results were obtained using ENV+ cartridges. Quality parameters such as day-to-day and run-to-run precision (RSD<10%), linearity (between 25 and 700 ng g(-1)) and detection limit (6 ng g(-1)) were established. This method was successfully applied to the analysis of HMF content in several Spanish food samples from a local market, such as jam, honey, orange juice and bakery products. PMID:17010355

  16. Targeted Chiral Analysis of Bioactive Arachidonic Acid Metabolites Using Liquid-Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Clementina Mesaros

    2012-04-01

    Full Text Available A complex structurally diverse series of eicosanoids arises from the metabolism of arachidonic acid. The metabolic profile is further complicated by the enantioselectivity of eicosanoid formation and the variety of regioisomers that arise. In order to investigate the metabolism of arachidonic acid in vitro or in vivo, targeted methods are advantageous in order to distinguish between the complex isomeric mixtures that can arise by different metabolic pathways. Over the last several years this targeted approach has become more popular, although there are still relatively few examples where chiral targeted approaches have been employed to directly analyze complex enantiomeric mixtures. To efficiently conduct targeted eicosanoid analyses, LC separations are coupled with collision induced dissociation (CID and tandem mass spectrometry (MS/MS. Product ion profiles are often diagnostic for particular regioisomers. The highest sensitivity that can be achieved involves the use of selected reaction monitoring/mass spectrometry (SRM/MS; whereas the highest specificity is obtained with an SRM transitions between an intense parent ion, which contains the intact molecule (M and a structurally significant product ion. This review article provides an overview of arachidonic acid metabolism and targeted chiral methods that have been utilized for the analysis of the structurally diverse eicosanoids that arise.

  17. Systematic Optimization of Long Gradient Chromatography Mass Spectrometry for Deep Analysis of Brain Proteome

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong; Yang, Yanling; Li, Yuxin; Bai, Bing; Wang, Xusheng; Tan, Haiyan; Liu, Tao; Beach, Thomas G.; Peng, Junmun; Wu, Zhiping

    2015-02-06

    Development of high resolution liquid chromatography (LC) is essential for improving the sensitivity and throughput of mass spectrometry (MS)-based proteomics. Here we present systematic optimization of a long gradient LC-MS/MS platform to enhance protein identification from a complex mixture. The platform employed an in-house fabricated, reverse phase column (100 μm x 150 cm) coupled with Q Exactive MS. The column was capable of achieving a peak capacity of approximately 700 in a 720 min gradient of 10-45% acetonitrile. The optimal loading level was about 6 micrograms of peptides, although the column allowed loading as many as 20 micrograms. Gas phase fractionation of peptide ions further increased the number of peptide identification by ~10%. Moreover, the combination of basic pH LC pre-fractionation with the long gradient LC-MS/MS platform enabled the identification of 96,127 peptides and 10,544 proteins at 1% protein false discovery rate in a postmortem brain sample of Alzheimer’s disease. As deep RNA sequencing of the same specimen suggested that ~16,000 genes were expressed, current analysis covered more than 60% of the expressed proteome. Further improvement strategies of the LC/LC-MS/MS platform were also discussed.

  18. Evaluation of beer deterioration by gas chromatography-mass spectrometry/multivariate analysis: a rapid tool for assessing beer composition.

    Science.gov (United States)

    Rodrigues, João A; Barros, António S; Carvalho, Beatriz; Brandão, Tiago; Gil, Ana M; Ferreira, António C Silva

    2011-02-18

    Beer stability is a major concern for the brewing industry, as beer characteristics may be subject to significant changes during storage. This paper describes a novel non-targeted methodology for monitoring the chemical changes occurring in a lager beer exposed to accelerated aging (induced by thermal treatment: 18 days at 45 °C), using gas chromatography-mass spectrometry in tandem with multivariate analysis (GC-MS/MVA). Optimization of the chromatographic run was performed, achieving a threefold reduction of the chromatographic time. Although losing optimum resolution, rapid GC runs showed similar chromatographic profiles and semi-quantitative ability to characterize volatile compounds. To evaluate the variations on the global volatile signature (chromatographic profile and m/z pattern of fragmentation in each scan) of beer during thermal deterioration, a non-supervised multivariate analysis method, Principal Component Analysis (PCA), was applied to the GC-MS data. This methodology allowed not only the rapid identification of the degree of deterioration affecting beer, but also the identification of specific compounds of relevance to the thermal deterioration process of beer, both well established markers such as 5-hydroxymethylfufural (5-HMF), furfural and diethyl succinate, as well as other compounds, to our knowledge, newly correlated to beer aging. PMID:21227435

  19. Fuzzy C-means clustering for chromatographic fingerprints analysis: A gas chromatography-mass spectrometry case study.

    Science.gov (United States)

    Parastar, Hadi; Bazrafshan, Alisina

    2016-03-18

    Fuzzy C-means clustering (FCM) is proposed as a promising method for the clustering of chromatographic fingerprints of complex samples, such as essential oils. As an example, secondary metabolites of 14 citrus leaves samples are extracted and analyzed by gas chromatography-mass spectrometry (GC-MS). The obtained chromatographic fingerprints are divided to desired number of chromatographic regions. Owing to the fact that chromatographic problems, such as elution time shift and peak overlap can significantly affect the clustering results, therefore, each chromatographic region is analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) to address these problems. Then, the resolved elution profiles are used to make a new data matrix based on peak areas of pure components to cluster by FCM. The FCM clustering parameters (i.e., fuzziness coefficient and number of cluster) are optimized by two different methods of partial least squares (PLS) as a conventional method and minimization of FCM objective function as our new idea. The results showed that minimization of FCM objective function is an easier and better way to optimize FCM clustering parameters. Then, the optimized FCM clustering algorithm is used to cluster samples and variables to figure out the similarities and dissimilarities among samples and to find discriminant secondary metabolites in each cluster (chemotype). Finally, the FCM clustering results are compared with those of principal component analysis (PCA), hierarchical cluster analysis (HCA) and Kohonon maps. The results confirmed the outperformance of FCM over the frequently used clustering algorithms.

  20. Analysis of glyphosate residues in cereals using liquid chromatography-mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Granby, Kit; Johannesen, S.; Gabrielsen, Martin Vahl

    2003-01-01

    -up) in series with an ion chromatography column (separation) using NaHCO3 as eluent. A micro-membrane suppressor was inserted after the separator column to remove the Na + ions before detection by electrospray ionization mass spectrometry in the negative-ion mode. In MS/MS, mode the following transitions were...

  1. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Jin; Shin, Yeon Jae; Oh, Se Yeon; Kim, Nam Sun; Kim, Kun; Lee, Dong Sun [Seoul Women' s University, Seoul (Korea, Republic of)

    2006-02-15

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (K{sub lh}) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

  2. Gas chromatography-mass spectrometry analysis of different organic crude extracts from the local medicinal plant of Thymus vulgaris L

    Institute of Scientific and Technical Information of China (English)

    Laila Salim Al Hashmi; Mohammad Amzad Hossain; Afaf Mohammed Weli; Qasim Al-Riyami; Jamal Nasser Al-Sabahi

    2013-01-01

    Objective: To isolate and analyze the chemical composition in different crude extracts of from the leaves of locally grown of Thymus vulgaris L (T. vulgaris) by gas chromatography-mass spectrometry (GC-MS). Methods: The shade dried leaves powder was extracted with methanol by using Soxhlet extractor. Methanol crude extracts of T. vulgaris and the derived fractions of hexane, chloroform, ethyl acetate and butanol were obtained. Results: Qualitative analyses of various organic crude extracts of T. vulgaris by using GC-MS showed that there were different types of high and low molecular weight compounds. Most of the isolated and identified compounds by GC-MS in the crude extracts are basically biologically important. Further, the T. vulgaris leaf possessed certain characteristics that can be ascribed to cultivation on a domestic plantation. The crude extracts were prepared from the powder leaves of T. vulgaris for respective compounds can be chosen on the basis of above GC-MS analysis. Conclusions: All the major compounds were identified and characterized by spectroscopic method in different organic crude extracts of T. vulgaris are biologically active molecules. Thus the identification of a good number of compounds in various crude extracts of T. vulgaris might have some ecological role.

  3. Gas chromatography-mass spectrometry analysis of different organic crude extracts from the local medicinal plant of Thymus vulgaris L

    Institute of Scientific and Technical Information of China (English)

    Laila; Salim; Al; Hashmi; Mohammad; Amzad; Hossain; Afaf; Mohammed; Weli; Qasim; Al-Riyami; Jamal; Nasser; Al-Sabahi

    2013-01-01

    Objective:To isolate and analyze the chemical composition in different crude extracts of from the leaves of locally grown of Thymus vulgaris L(T.vulgaris)by gas chromatography-mass spectrometry(GC-MS).Methods:The shade dried leaves powder was extracted with methanol by using Soxhlet extractor.Methanol crude extracts of T.vulgaris and the derived fractions of hexane,chloroform,ethyl acetate and butanol were obtained.Results:Qualitative analyses of various organic crude extracts of T.vulgaris by using GC-MS showed that there were different types of high and low molecular weight compounds.Most of the isolated and identified compounds by GC-MS in the crude extracts are basically biologically important.Further,the T.vulgaris leaf possessed certain characteristics that can be ascribed to cultivation on a domestic plantation.The crude extracts were prepared from the powder leaves of T.vulgaris for respective compounds can be chosen on the basis of above GC-MS analysis.Conclusions:All the major compounds were identified and characterized by spectroscopic method in different organic crude extracts of T.vulgaris are biologically active molecules.Thus the identification of a good number of compounds in various crude extracts of T.vulgaris might have some ecological role.

  4. Gas Chromatography-Mass Spectrometry Analysis of Constituent Oil from Lingzhi or Reishi Medicinal Mushroom, Ganoderma lucidum (Agaricomycetes), from Nigeria.

    Science.gov (United States)

    Ohiri, Reginald Chibueze; Bassey, Essien Eka

    2016-01-01

    Gas chromatography-mass spectrometry analysis of constituent oil from dried Ganoderma lucidum was carried out. Fresh G. lucidum obtained from its natural environment was thoroughly washed with distilled water and air-dried for 2 weeks and the component oils were extracted and analyzed. Four predominant components identified were pentadecanoic acid, 14-methyl-ester (retention time [RT] = 19.752 minutes; percentage total = 25.489), 9,12-octadecadienoic acid (Z,Z)- (RT = 21.629 minutes and 21.663 minutes; percentage total = 25.054), n-hexadecanoic acid (RT = 20.153 minutes; percentage total = 24.275), and 9-octadecenoic acid (Z)-, methyl ester (RT = 21.297 minutes; percentage total = 13.027). The two minor oils identified were 9,12-octadecadienoic acid, methyl ester, (E,E)- and octadecanoic acid, methyl ester (RT = 21.246 minutes and 21.503 minutes; percentage total = 7.057 and 5.097, respectively). PMID:27481303

  5. [Fast analysis of common fatty acids in edible vegetable oils by ultra-performance convergence chromatography-mass spectrometry].

    Science.gov (United States)

    Lin, Chunhua; Xie, Xianqing; Fan, Naili; Tu, Yuanhong; Chen, Yan; Liao, Weilin

    2015-04-01

    A fast analytical method for five common fatty acids in six edible vegetable oils was developed by ultra-performance convergence chromatography-mass spectrometry (UPC2-MS). The five fatty acids are palmitic acid, stearic acid, oleic acid, linoleic acid and linolenic acid. Their contents in the corn oil, sunflower oil, soybean oil, tea oil, rapeseed oil and peanut oil were compared. The chromatographic separation was performed on an ACQUITY UPC2 BEH 2-EP column (100 mm x 2.1 mm, 1.7 µm) using the mobile phases of carbon dioxide and methanol/acetonitrile (1:1, v/v) with gradient elution. The separated compounds were detected by negative electrospray ionization ESF-MS. The results showed that the reasonable linearities were achieved for all the analytes over the range of 0.5-100 mg/L with the correlation coefficients (R2) of 0.9985-0.9998. The limits of quantification (S/N ≥ 10) of the five fatty acids were 0.15-0.50 mg/L. The recoveries of the five fatty acids at three spiked levels were in the range of 89.61%-108.50% with relative standard deviations of 0.69%-3.01%. The developed method showed high performance, good resolution and fast analysis for the underivatized fatty acids. It has been successfully used to detect the five fatty acids from corn oil, sunflower oil, soybean oil, tea oil rapeseed oil and peanut oil. PMID:26292410

  6. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    International Nuclear Information System (INIS)

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (Klh) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS

  7. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSDarbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.). PMID:26444340

  8. Analysis of aromatic hydrocarbons in petroleum fractions using gas chromatography, mass spectrometry and mass fragmentrography

    Energy Technology Data Exchange (ETDEWEB)

    Kubelka, V.

    1980-01-01

    Mass spectrometry in combination with gas chrom. used to analyze hydrocarbon mixtures results in qualit. and semi-quant. data regarding composition of the analyzed mixture. Use of mass fragmentrography during chromatographic separation will allow simultaneous recording of changes in intensity of characteristic ions and thus determine the retention index, for this substance. Combining mass spectre and retention index, it is possible to identify the given subst. or limit the number of possible combinations.

  9. Identification of microorganisms based on headspace analysis of volatile organic compounds by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Boots, A W; Smolinska, A; van Berkel, J J B N; Fijten, R R R; Stobberingh, E E; Boumans, M L L; Moonen, E J; Wouters, E F M; Dallinga, J W; Van Schooten, F J

    2014-06-01

    The identification of specific volatile organic compounds (VOCs) produced by microorganisms may assist in developing a fast and accurate methodology for the determination of pulmonary bacterial infections in exhaled air. As a first step, pulmonary bacteria were cultured and their headspace analyzed for the total amount of excreted VOCs to select those compounds which are exclusively associated with specific microorganisms. Development of a rapid, noninvasive methodology for identification of bacterial species may improve diagnostics and antibiotic therapy, ultimately leading to controlling the antibiotic resistance problem. Two hundred bacterial headspace samples from four different microorganisms (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Klebsiella pneumoniae) were analyzed by gas chromatography-mass spectrometry to detect a wide array of VOCs. Statistical analysis of these volatiles enabled the characterization of specific VOC profiles indicative for each microorganism. Differences in VOC abundance between the bacterial types were determined using ANalysis of VAriance-principal component analysis (ANOVA-PCA). These differences were visualized with PCA. Cross validation was applied to validate the results. We identified a large number of different compounds in the various headspaces, thus demonstrating a highly significant difference in VOC occurrence of bacterial cultures compared to the medium and between the cultures themselves. Additionally, a separation between a methicillin-resistant and a methicillin-sensitive isolate of S. aureus could be made due to significant differences between compounds. ANOVA-PCA analysis showed that 25 VOCs were differently profiled across the various microorganisms, whereas a PCA score plot enabled the visualization of these clear differences between the bacterial types. We demonstrated that identification of the studied microorganisms, including an antibiotic susceptible and resistant S. aureus substrain

  10. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  11. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  12. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  13. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-01-01

    g/mL). All other extracts were nontoxic. A total of 145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. Conclusions: The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. SUMMARY Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. PMID:27279705

  14. Gas chromatography mass spectrometry computer analysis of volatile halogenated hydrocarbons in man and his environment--A multimedia environmental study.

    Science.gov (United States)

    Barkley, J; Bunch, J; Bursey, J T; Castillo, N; Cooper, S D; Davis, J M; Erickson, M D; Harris, B S; Kirkpatrick, M; Michael, L C; Parks, S P; Pellizzari, E D; Ray, M; Smith, D; Tomer, K B; Wagner, R; Zweidinger, R A

    1980-04-01

    As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatography mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.

  15. Gas chromatography mass spectrometry computer analysis of volatile halogenated hydrocarbons in man and his environment--A multimedia environmental study.

    Science.gov (United States)

    Barkley, J; Bunch, J; Bursey, J T; Castillo, N; Cooper, S D; Davis, J M; Erickson, M D; Harris, B S; Kirkpatrick, M; Michael, L C; Parks, S P; Pellizzari, E D; Ray, M; Smith, D; Tomer, K B; Wagner, R; Zweidinger, R A

    1980-04-01

    As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatography mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined. PMID:7448328

  16. Multi-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS

    Directory of Open Access Journals (Sweden)

    Azadeh Emami

    2014-12-01

    Full Text Available Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket. Methods: We developed a "Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS method based on spiking blank samples and used the data for drawing calibration curves instead of standard solutions. Sample preparations were developed for determination of 12 pesticide residues in pistachio by gas chromatography-mass spectrometry (GC/MS. Results: Recovery of pesticides at 5 concentration levels (n=3 was in the range of 81.40% - 93.08 %. The method proved to be repeatable in the majority of samples with relative standard deviation (RSD of lower than 20%. The limits of detection and quantification for all pesticides were 2 ppb and 10 ppb, respectively. Conclusion: The calibration curves of pesticides were linear in the range of 10-500 (ng/g and correlation coefficient of entire pesticides was higher than 0.994. The recovery of pesticides at 5 concentration levels (n=3 was in range of 81.41- 91.80 %. The method was proved to be repeatable with the majority of RSDs being lower than 20%. The limits of detection and quantification for all pesticides were 2 and 10 ppb, respectively. The recoveries and repeatabilities were in accordance with the criteria set by SANCO Guideline (Commission of the European Communities, 2006.

  17. Analysis of volatile compounds responsible for kiwifruit aroma by desiccated headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Chun-Yun; Zhang, Qiong; Zhong, Cai-Hong; Guo, Ming-Quan

    2016-04-01

    A new method for desiccated headspace (DHS) sampling of aqueous sample to GC-MS for the analysis of volatile compounds responsible for kiwifruit aroma in different kiwifruit cultivars has been developed based on the complete hydrate formation between the sample solvent (water) with anhydrous salt (calcium chloride) at an elevated temperature (above the boiling point of the aqueous sample) in a non-contact format, which overcame the water-effect challenge to directly introduce aqueous sample into GC-MS analysis. By means of DHS, the volatile compounds in three different kiwifruit cultivars were analyzed and compared under the optimized operating conditions, mainly time and temperature for headspace equilibration, column temperature program for GC-MS measurement. As a result, 20 peaks of volatile compounds responsible for kiwifruit aroma were detected and remarkable differences were found in the relative contents of three major volatile compounds among the three different kiwifruit cultivars, i.e., acetaldehyde, ethanol and furfural. The DHS sampling technique used in the present method can make the GC-MS analysis of volatile compounds in the aqueous sample within complex matrix possible without contaminating the GC-MS instrument. In terms of the analysis of volatile compounds in kiwifruit, the present method enabled a direct measurement on the filtrate of the aqueous kiwifruit pulp, without intermediate trap phase for the extraction of analytes, which will be more reliable and simpler as compared with any other headspace method in use. Thus, DHS coupled with GC-MS will be a new valuable tool available for the kiwifruit related research and organoleptic quality control. PMID:26922094

  18. Recent advances and trends in the liquid-chromatography-mass spectrometry analysis of flavonoids.

    Science.gov (United States)

    de Villiers, André; Venter, Pieter; Pasch, Harald

    2016-01-22

    Flavonoids have elicited significant attention as a result of their importance in plants, their influence on the properties of natural-product derived commodities and especially as a consequence of their purported health benefits. Research in all of these fields relies heavily on accurate analytical data, and in this LC-MS has come to play an influential role by allowing relatively fast tentative identification and accurate quantification of low levels of flavonoids in a variety of matrices. The field has undergone rapid expansion in the last decade due to important developments in both HPLC and MS instrumentation, which nowadays allow much faster and more accurate analysis of flavonoids. This contribution aims to provide an overview of these developments and their application in flavonoid analysis since 2009. The discussion is focussed first on methodologies which provide improved LC separation of flavonoids in terms of speed and/or resolution, including ultra high pressure LC (UHPLC), monolithic and superficially porous phases, high temperature LC (HTLC) and comprehensive two-dimensional LC (LC×LC). The fundamental background relevant to each of these will be briefly outlined, as well as the implications and promise of their hyphenation to MS. Secondly, the possibilities and limitations of a range of the latest MS instruments available in combination with advanced LC analysis will be discussed, including ion trap, triple quadrupole, time-of-flight, Orbitrap, ion mobility and various hybrid instruments. Examples from the latest literature will be used to illustrate the performance gains achievable in flavonoid analysis by the hyphenation of advanced LC separation and high-end MS instrumentation.

  19. ANALYSIS OF CHEMICAL COMPOUNDS OF AGARWOOD OIL FROM DIFFERENT SPECIES BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GCMS)

    OpenAIRE

    Yumi Zuhanis Has-Yun Hashim; Nur Izzah Ismail; Phirdaous Abbas

    2014-01-01

    ABSTRACT: Agarwood oil is a highly prized type of oil due to its unique aroma. The oil is extracted from the fragrant resin found in the agarwood tree (trunk).  The unique aroma and quality of agarwood resin and oil are contributed by the presence of certain chemical compounds. In this work, analysis and comparison of the chemical compounds of agarwood oil from A. malaccensis, A. sub-integra and a mixture of both were conducted.  The essential oils were diluted in hexane (5%) prior to gas chr...

  20. Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

    Science.gov (United States)

    Merritt, Dawn A.; Hayes, J. M.; Des Marais, David J.

    1995-01-01

    Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

  1. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSD<5%), analytical recovery (96.2-98.0%), and sensitivity (limit of detection=0.009 and 0.004 μg mL(-1) for arbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.).

  2. Analysis of pharmaceutical and other organic wastewater compounds in filtered and unfiltered water samples by gas chromatography/mass spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Phillips, Patrick J.; Smith, Steven G.

    2014-01-01

    types were determined by use of the capillary-column gas chromatography/mass spectrometry. The performance of each method was assessed by using data on recoveries of compounds in fortified surface-water, wastewater, and reagent-water samples. These experiments (referred to as spike experiments) consist of fortifying (or spiking) samples with known amounts of target analytes. Surface-water-spike experiments were performed by using samples obtained from a stream in Colorado (unfiltered method) and a stream in New York (filtered method). Wastewater spike experiments for both the filtered and unfiltered methods were performed by using a treated wastewater obtained from a single wastewater treatment plant in New York. Surface water and wastewater spike experiments were fortified at both low and high concentrations and termed low- and high-level spikes, respectively. Reagent water spikes were assessed in three ways: (1) set spikes, (2) a low-concentration fortification experiment, and (3) a high-concentration fortification experiment. Set spike samples have been determined since 2009, and consist of analysis of fortified reagent water for target compounds included for each group of 10 to18 environmental samples analyzed at the NWQL. The low-concentration and high-concentration reagent spike experiments, by contrast, represent a one-time assessment of method performance. For each spike experiment, mean recoveries ranging from 60 to 130 percent indicate low bias, and relative standard deviations (RSDs) less than ( Of the compounds included in the filtered method, 21 had mean recoveries ranging from 63 to 129 percent for the low-level and high-level surface-water spikes, and had low ()132 percent]. For wastewater spikes, 24 of the compounds included in the filtered method had recoveries ranging from 61 to 130 percent for the low-level and high-level spikes. RSDs were 130 percent) or variable recoveries (RSDs >30 percent) for low-level wastewater spikes, or low recoveries ( Of

  3. Analysis of volatile chemical components of Radix Paeoniae Rubra by gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-ru; LAN Zheng-gang; LIANG Yi-zeng

    2007-01-01

    The volatile chemical components of Radix Paeoniae Rubra (RPR) were analyzed by gas chromatography-mass spectrometry with the method of heuristic evolving latent projections and overall volume integration.The results show that 38 volatile chemical components of RPR are determined.accounting for 95.21% of total contents of volatile chemical components of RPR.The main volatile chemical components of RPR are(Z,Z)-9, 12-octadecadienoic acid, n-hexadecanoic acid, 2-hydroxy benzaldehyde, 1-(2-hydroxy-4-methoxyphenyl)-ethanone, 6,6-dimethyl-bicyclo[3.1.1]heptane-2-methanol, 4,7-dimethyl-benzofuran, 4-(1-methylethenyl)-1-cyclohexene-1-carboxaldehyde, and cyclohexadecane.

  4. Gas chromatography-mass spectrometry analysis of fatty acid profiles of Antarctic and non-Antarctic yeasts.

    Science.gov (United States)

    Bhuiyan, Mohammad; Tucker, David; Watson, Kenneth

    2014-08-01

    The fatty acid profiles of Antarctic (n = 7) and non-Antarctic yeasts (n = 7) grown at different temperatures were analysed by gas chromatography-mass spectrometry. The Antarctic yeasts were enriched in oleic 18:1 (20-60 %), linoleic 18:2 (20-50 %) and linolenic 18:3 (5-40 %) acids with lesser amounts of palmitic 16:0 (Antarctic yeasts (n = 4) were enriched in 18:1 (20-55 %, with R. mucilaginosa at 75-80 %) and 18:2 (10-40 %) with lesser amounts of 16:0 (Antarctic yeasts (enriched in 18:1 and 18:2) and the third to the Antarctic yeasts (enriched in 18:2 and 18:3).

  5. Response to weaning and dietary L-glutamine supplementation:metabolomic analysis in piglets by gas chromatography/mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Ying-ping XIAO; Tian-xing WU; Qi-hua HONG; Jiang-ming SUN; An-guo CHEN; Cai-mei YANG; Xiao-yan LI

    2012-01-01

    A novel metabolomic method based on gas chromatography/mass spectrometry (GC-MS) was applied to determine the metabolites in the serum of piglets in response to weaning and dietary L-glutamine (Gln) supplementation.Thirty six 21-d-old piglets were randomly assigned into three groups.One group continued to suckle from the sows (suckling group),whereas the other two groups were weaned and their diets were supplemented with 1% (w/w) Gln or isonitrogenous L-alanine,respectively,representing Gin group or control group.Serum samples were collected to characterize metabolites after a 7-d treatment.Results showed that twenty metabolites were down-regulated signifi cantly (P<0.05) in control piglets compared with suckling ones.These data demonstrated that early weaning causes a wide range of metabolic changes across arginine and proline metabolism,aminosugar and nucleotide metabolism,galactose metabolism,glycerophospholipid metabolism,biosynthesis of unsaturated fatty acid,and fatty acid metabo lism.Dietary Gin supplementation increased the levels of creatinine,o-xylose,2-hydroxybutyric acid,palmitelaidic acid,and α-L- galactofuranose (P<0.05) in early weaned piglets,and were involved in the arginine and proline metabolism,carbohydrate metabolism,and fatty acid metabolism.A leave one out cross validation of random forest analysis indi cated that creatinine was the most important metabolite among the three groups.Notably,the concentration of craatinine in control piglets was decreased (P=0.00001) compared to the suckling piglets,and increased (P=0.0003) in Gin-supplemented piglets.A correlation network for weaned and suckling piglets revealed that eady weaning changed the metabolic pathways,leading to the abnormality of carbohydrate metabolism,amino acid metabolism,and lipid metabolism,which could be partially improved by dietary Gin supplementation.These findings provide fresh insight into the complex metabolic changes in response to early weaning and dietary Gin

  6. Titan's organic aerosols: Molecular composition and structure of laboratory analogues inferred from pyrolysis gas chromatography mass spectrometry analysis

    Science.gov (United States)

    Morisson, Marietta; Szopa, Cyril; Carrasco, Nathalie; Buch, Arnaud; Gautier, Thomas

    2016-10-01

    Analogues of Titan's aerosols are of primary interest in the understanding of Titan's atmospheric chemistry and climate, and in the development of in situ instrumentation for future space missions. Numerous studies have been carried out to characterize laboratory analogues of Titan aerosols (tholins), but their molecular composition and structure are still poorly known. If pyrolysis gas chromatography mass spectrometry (pyr-GCMS) has been used for years to give clues about their chemical composition, highly disparate results were obtained with this technique. They can be attributed to the variety of analytical conditions used for pyr-GCMS analyses, and/or to differences in the nature of the analogues analyzed, that were produced with different laboratory set-ups under various operating conditions. In order to have a better description of Titan's tholin's molecular composition by pyr-GCMS, we carried out a systematic study with two major objectives: (i) exploring the pyr-GCMS analytical parameters to find the optimal ones for the detection of a wide range of chemical products allowing a characterization of the tholins composition as comprehensive as possible, and (ii) highlighting the role of the CH4 ratio in the gaseous reactive medium on the tholin's molecular structure. We used a radio-frequency plasma discharge to synthetize tholins with different concentrations of CH4 diluted in N2. The samples were pyrolyzed at temperatures covering the 200-700°C range. The extracted gases were then analyzed by GCMS for their molecular identification. The optimal pyrolysis temperature for characterizing the molecular composition of our tholins by GCMS analysis is found to be 600°C. This temperature choice results from the best compromise between the number of compounds released, the quality of the signal and the appearance of pyrolysis artifacts. About a hundred molecules are identified as pyrolysates. A common major chromatographic pattern appears clearly for all the

  7. Pressurized liquid extraction-gas chromatography-mass spectrometry analysis of fragrance allergens, musks, phthalates and preservatives in baby wipes.

    Science.gov (United States)

    Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria

    2015-03-01

    Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between

  8. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  9. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  10. Analysis of pharmaceutical and other organic wastewater compounds in filtered and unfiltered water samples by gas chromatography/mass spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Phillips, Patrick J.; Smith, Steven G.

    2014-01-01

    types were determined by use of the capillary-column gas chromatography/mass spectrometry. The performance of each method was assessed by using data on recoveries of compounds in fortified surface-water, wastewater, and reagent-water samples. These experiments (referred to as spike experiments) consist of fortifying (or spiking) samples with known amounts of target analytes. Surface-water-spike experiments were performed by using samples obtained from a stream in Colorado (unfiltered method) and a stream in New York (filtered method). Wastewater spike experiments for both the filtered and unfiltered methods were performed by using a treated wastewater obtained from a single wastewater treatment plant in New York. Surface water and wastewater spike experiments were fortified at both low and high concentrations and termed low- and high-level spikes, respectively. Reagent water spikes were assessed in three ways: (1) set spikes, (2) a low-concentration fortification experiment, and (3) a high-concentration fortification experiment. Set spike samples have been determined since 2009, and consist of analysis of fortified reagent water for target compounds included for each group of 10 to18 environmental samples analyzed at the NWQL. The low-concentration and high-concentration reagent spike experiments, by contrast, represent a one-time assessment of method performance. For each spike experiment, mean recoveries ranging from 60 to 130 percent indicate low bias, and relative standard deviations (RSDs) less than ( Of the compounds included in the filtered method, 21 had mean recoveries ranging from 63 to 129 percent for the low-level and high-level surface-water spikes, and had low ()132 percent]. For wastewater spikes, 24 of the compounds included in the filtered method had recoveries ranging from 61 to 130 percent for the low-level and high-level spikes. RSDs were 130 percent) or variable recoveries (RSDs >30 percent) for low-level wastewater spikes, or low recoveries ( Of

  11. Analysis for chloroanisoles and chlorophenols in cork by stir bar sorptive extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Callejon, R M; Troncoso, A M; Morales, M L

    2007-03-30

    A complete methodology for the determination of chloroanisoles and chlorophenols in cork material is proposed. The determination is accomplished by means of a previous liquid-solid extraction followed by stir bar sorptive extraction (SBSE) coupled to gas chromatography-mass spectrometry (GC-MS). Two different liquid-solid extraction experiments were conducted and eight compounds considered (2,6-dichloroanisole, 2,4-dichloroanisole, 2,4,6-trichloroanisole, 2,4,6-trichlorophenol, 2,3,4,6-tetrachloroanisole, 2,3,4,6-tetrachlorophenol, pentachloroanisole and pentachlorophenol). From the results obtained we can conclude that high volume extraction extending extraction time up to 24h is the best choice if we have to release compounds from the inner surfaces of cork stoppers. Recovery percentages ranged from 51% for pentachloroanisole to 81% for 2,4-dichloroanisole. This method allows the determination of an array of compounds involved in cork taint at very low levels from 1.2ng g(-1) for 2,4,6-tricholoroanisole to 23.03ng g(-1) for 2,3,4,6-tetrachlorophenol. PMID:19071569

  12. A metabolic profiling analysis of the nephrotoxicity of acyclovir in rats using ultra performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Xing, Wenmin; Gu, Lili; Zhang, Xinyue; Xu, Jiadong; Lu, Hong

    2016-09-01

    Acyclovir (ACV) exposure is a common cause of acute kidney injury (AKI). The toxicity mechanism of ACV has always been a matter of debate. The present study investigated into the time-effect relationship and dose-effect relationship of ACV-induced nephrotoxicity in rats using metabonomics. Twenty-four rats were randomly divided into four groups: a 0.9% NaCl solution group, and 100, 300, and 600mg/kg ACV-treated groups; the ACV or vehicle solution was administered with a single intravenous injection. Urine was collected at different time periods (12h before administration, and 0-6h, 7-12h, and 13-24h after administration). Routine urinalysis was conducted by a urine automatic analyzer. Renal markers, including urine urea nitrogen, urine creatinine, and urinary N-acetyl-β-d-glucosaminidase (NAG) activity, were determined using established protocols. Urinary metabolites were evaluated using ultra performance liquid chromatography/mass spectrometry (UPLC/MS). In the ACV-treated rats, increased levels of protein (PRO), occult blood (BLD), white blood cell (WBC), and NAG activity in urine were observed, while the urine creatinine and urea nitrogen levels showed a decrease compared with the control. Moreover, urine metabolites significantly changed after the treatment with ACV, and all the effects induced by ACV were dose-time dependent. Finally, 4 metabolites (guanine, 4-guanidinobutyric acid, creatinine, and urea) were identified, which can be used for further research on the mechanism of ACV-induced nephrotoxicity.

  13. Radiogas chromatography mass spectrometry in the selected ion monitoring mode

    International Nuclear Information System (INIS)

    The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid in Penicillium brevicompactum and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. Both examples used 1-[14C]acetate precursors. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed. (author)

  14. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  15. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    Science.gov (United States)

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  16. Pyrolysis - gas chromatography - mass spectrometry of lignins

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F.; Saiz-Jimenez, C.; Gonzalez-Vila, F.J.

    1979-01-01

    Milled wood lignins from spruce, beech and bamboo were pyrolysed. The high-boiling products of pyrolysis were studied by GLC and mass spectrometry. The forty-three products identified provide information on the structural units of lignin.

  17. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  18. Microextraction and Gas Chromatography/Mass Spectrometry for improved analysis of geosmin and other fungal "off" volatiles in grape juice.

    Science.gov (United States)

    Morales-Valle, H; Silva, L C; Paterson, R R M; Oliveira, J M; Venâncio, A; Lima, N

    2010-10-01

    Geosmin is a volatile fungal metabolite with an earthy aroma produced in grape products from rotten grapes. The accumulation of geosmin in grapes is caused by the interaction of Botrytis cinerea and Penicillium expansum. Solid Phase Microextraction (SPME) has great utility for collecting volatile compounds in wine. However, contamination with earthy odours may have occurred previously in the must and novel methods are required for this commodity. In the present report, several parameters of the SPME were evaluated to optimize geosmin extraction. The method permitted quantification of geosmin and other fungal volatiles by Gas Chromatography-Mass Spectrometer (GC-MS) at very low concentrations. Limits of detection and quantification (L(D) and L(Q)) for geosmin were 4.7 ng L(-1) and 15.6 ng L(-1) respectively. The RSD was 4.1% and the recovery rates ranged from 115% to 134%. Uniquely, haloanisoles were analyzed by using only one internal standard (2,3,6-trichloroanisole) thus avoiding the synthesis of deuterated anisole analogues that are used as internal standard in other methods. The method was used for the analysis of grape juice samples inoculated with B. cinerea and P. expansum. Geosmin and methylisoborneol were the compounds that appeared to contribute most to earthy odours, although other fungal compounds which are claimed to cause earthy or mouldy off-odours were detected (e.g. 1-octen-3-ol and fenchol).

  19. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    Science.gov (United States)

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  20. Carbon isotope ratio analysis of organic moieties from fossil mummified wood: establishing optimum conditions for off-line pyrolysis extraction using gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Poole, I.J.; Bergen, P.F. van

    2002-01-01

    Mummified fossil wood was studied using off-line pyrolysis-gas chromatography/mass spectrometry to reveal detailed insights into the pyrolysis conditions that are needed to obtain simultaneously sufficient amounts of both cellulose and lignin markers for stable carbon isotope analyses. The off-line

  1. Triclosan and methyl-triclosan monitoring study in the northeast of Spain using a magnetic particle enzyme immunoassay and confirmatory analysis by gas chromatography mass spectrometry

    Science.gov (United States)

    Kantiani, Lina; Farré, Marinella; Asperger, Danijela; Rubio, Fernando; González, Susana; López de Alda, Maria J.; Petrović, Mira; Shelver, Weilin L.; Barceló, Damià

    2008-10-01

    SummaryFor the first time, the occurrence of triclosan and its metabolite methyl-triclosan was investigated in a typical Mediterranean area using a two-step methodology based on screening using a magnetic particle immunoassay (IA) and confirmatory analysis by solid phase extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS). In this study, 95 environmental samples were analyzed. A commercial immunoassay was assessed for use in the different types of water selected for this study. A large monitoring study was performed on the influent and the effluent of eight wastewater treatment plants (WWTPs), water samples from Ebro and Llobregat rivers, and drinking water. All wastewater samples tested in this study (influents and effluents) showed the presence of triclosan, with concentrations for raw influents being high (10 μg/L as average value). The percentages of triclosan removal for the WWTPs were evaluated (30-70%) along the different treatment processes showing that the best removal rates were obtained by the processes equipped with membrane bioreactors (MBRs). However, important concentrations of triclosan were detected even after treatment by MBRs. The presence of this biocide was confirmed in 50% of the river samples analyzed. Twenty two drinking water samples from the Barcelona city area were investigated, and in this case no triclosan was detected. Due to its properties and the widespread usage of triclosan, there is a need for monitoring and controlling the amounts present in wastewater effluents, river water, drinking water catchments areas, and drinking water. To this end, we present a feasible methodology using a magnetic particle-based immunoassay as a screening, followed by confirmatory analysis using solid phase extraction-gas chromatography-mass spectrometry (SPE-GC-MS).

  2. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-04-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry (MHSE), respectively. The monoterpenes were 1st extracted by means of supercritical fluid extraction (SFE) and analyzed by an optimized DHS-GC-MS. The optimization of the dynamic extraction step and the desorption/cryo-focusing step were tackled independently by experimental design assays. The best working conditions were set at 30 °C for the incubation temperature, 5 min of incubation time, and 40 mL of purge volume for the dynamic extraction step of these bioactive molecules. The conditions of the desorption/cryo-trapping step from the Tenax TA trap were set at follows: the temperature was increased from 30 to 300 °C at 150 °C/min, although the cryo-trapping was maintained at -70 °C. In order to estimate the efficiency of the SFE process, the analysis of monoterpenes in the 4 aromatic plants was directly carried out by means of MHSE because it did not require any sample preparation. Good linearity (r2) > 0.99) and reproducibility (relative standard deviation % <12) was obtained for solid and liquid quantification approaches, in the ranges of 0.5 to 200 ng and 10 to 500 ng/mL, respectively. The developed methods were applied to analyze the concentration of 7 monoterpenes in aromatic plants obtaining concentrations in the range of 2 to 6000 ng/g and 0.25 to 110 μg/mg, respectively. PMID:26925555

  3. Analysis of Volatile Metabolites Released by Staphylococcus Aureus using Gas Chromatography-Mass Spectrometry and Determination of its Antifungal Activity

    Directory of Open Access Journals (Sweden)

    Hayfaa Hussein Jaddoa

    2016-08-01

    Full Text Available Bacterial volatile organic compounds (VOCs have been considered as sensitive and specific biomarkers for bacterial detection in human specimens and culture media. The possibility of using VOCs markers as one of the largest groups of bacterial metabolites would open a new frontier for developing more efficient techniques in the diagnosis of bacterial infections. The aims of this research were analysis of the bioactive chemical products and evaluation of antibacterial and antifungal activity. Bioactives (chemical compounds often referred to as secondary metabolites were analyzed using gas chromatography-mass spectroscopy (GC-MS techniques, then the in vitro antibacterial and antifungal activity of the methanolic extract was evaluated. Thirty five bioactive compounds were identified in the methanolic extract of Staphylococcus aureus. GC-MS analysis of Staphylococcus aureus revealed the existence of the: Hexanoic acid , 2-methyl, 12,15-Octadecadiynoic acid , methyl ester, 1-Aminononadecane ,N-trifluoroacetyl-, N-[3-[N-Aziridyl]propylidene]hexylamine, N-(2,5-Dicyano-3,4-dihydro-2H-pyrrol-2-yl-acetamide, 3-Cyclohex-3-enyl-propionic acid, 1-Methyl-4-[nitromethyl]-4-piperidinol, 3-Azonia-5-hexyn-1-ol , N,N-dimethyl-O-acetyl-,bromide, 1-Hexadecanol -2-methyl-, 1-Propyl-3,6-diazahomoadamantan, 9-Borabicyclo[3.3.1]nonane , 9-mercapto-, Benzyl methyl ketone, L-Aspartic acid ,N-glycyl-, Aminoacetamide , N-methyl-N-[4-(1-pyrrolidinyl-2-butynyl]-, Tertbutyloxyformamide , N-methyl-N-[4-(1-pyrrolidinyl-2-butyn, 5,7-Dodecadiyn-1,12-diol, Deoxyspergualin, D-Streptamine , O-6-deoxy-α-D-glucopyranosyl-(1-4, dl-Citrulline, N-[3-Diethylaminopropyl]-4-oxo-1,2,3,4,5,6,7,8-octahydroqui, N-Propionyl-D-glucoseamine, Cystine, 3,4-Dihydrocoumarin ,6-fluoro-4,4-dimethyl-, 4-(2,5-Dihydro-3-methoxyphenylbutylamine, 3-methoxy-2-(1-methylethyl-5-(2-methylpropylpyrazine, Uric acid, Thiocyanic acid 4-methoxy-2,6-dimethyl-3-pyridyl ester, 12-Dimethylamino-10-oxododecanoic acid

  4. Comparative analysis of essential oils found in Rhizomes Curcumae and Radix Curcumae by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Di-Ya Lu; Yan Cao; Ling Li; Zhen-Yu Zhu; Xin Dong; Hai Zhang; Yi-Feng Chai; Zi-Yang Lou

    2011-01-01

    A comparison of the volatile compounds in Rhizomes Curcumae (Ezhu) and Radix Curcumae (Yujin) was undertaken using gas chromatography mass spectrometi-y (GC-MS). Ultrasonic extraction and GC-MS methods were developed for the simultaneous determination of five sesquiterpenes, namely, α-pinene, β-elemene, curcumol, germacrone and curdione, in Ezhu and Yunjin. Good linearity (r〉0.999) and high inter-day precision were observed over the investigated concentration ranges. The validated method was successfully used for the simultaneous determination of five sesquiterpenes in Ezhu and Yujin. The quantitative method can be effectively used to evaluate and monitor the quality of Chinese curcuma in clinical use.

  5. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Willemse, S.; Zeng, T.; Asten, A. van; Koeberg, M.; Heijden, A.E.D.M. van der; Bolck, A.; Schoenmakers, P.

    2014-01-01

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times the analysis of impurities in TNT was performed in

  6. Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón Fernando; del Carmen Estrada-Montoya, María

    2004-09-01

    Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

  7. Analysis of liposoluble carboxylic acids metabolome in human serum by stable isotope labeling coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zhu, Quan-Fei; Zhang, Zheng; Liu, Ping; Zheng, Shu-Jian; Peng, Ke; Deng, Qian-Yun; Zheng, Fang; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-08-19

    Fatty acids (FAs) are groups of liposoluble carboxylic acids (LCAs) and play important roles in various physiological processes. Abnormal contents or changes of FAs are associated with a series of diseases. Here we developed a strategy with stable isotope labeling combined with liquid chromatography-tandem mass spectrometry (IL-LC-MS) analysis for comprehensive profiling and relative quantitation of LCAs in human serum. In this strategy, a pair of isotope labeling reagents (2-dimethylaminoethylamine (DMED)) and d4-2-dimethylaminoethylamine (d4-DMED) were employed to selectively label carboxyl groups of LCAs. The DMED and d4-DMED labeled products can lose four characteristic neutral fragments of 45 and 49Da or 63 and 67Da in collision-induced dissociation. Therefore, quadruple neutral loss scan (QNLS) mode was established and used for non-targeted profiling of LCAs. The peak pairs of DMED and d4-DMED labeling with the same retention time, intensity and characteristic mass differences were extracted from the two NLS spectra respectively, and assigned as potential LCA candidates. Using this strategy, 241 LCA candidates were discovered in the human serum; 156 carboxylic acid compounds could be determined by searching HMDB and METLIN databases (FAs are over 90%) and 21 of these LCAs were successfully identified by standards. Subsequently, a modified pseudo-targeted method with multiple reaction monitoring (MRM) detection mode was developed and used for relative quantification of LCAs in human serum from type 2 diabetes mellitus (T2DM) patients and healthy controls. As a result, 81 LCAs were found to have significant difference between T2DM patients and healthy controls. Taken together, the isotope labeling combined with tandem mass spectrometry analysis demonstrated to be a powerful strategy for identification and quantification of LCA compounds in serum samples. PMID:27432792

  8. Simultaneous Organic and Inorganic Analysis of Colored Oriental Lacquerware by Pyrolysis-Gas Chromatography/Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yoshimi Kamiya

    2015-01-01

    Full Text Available Organic analysis and inorganic analysis are generally based on different physical principles, and for this reason it is difficult to analyze resins and pigments simultaneously. For these reasons, we have performed Py-GC/MS measurements of red-, yellow-, and green-colored lacquer films applied to lacquerware items to assess the feasibility of simultaneously detecting resin ingredients together with certain pigments. We have also compared our findings to the results of SEM-EDS, X-ray fluorescence spectrometry (XRF, and X-ray diffractometry (XRD measurements. XRD analysis yielded molecular-level information (information on binding states regarding mercury (Hg and iron (Fe; however, the information obtained for arsenic (As and sulfur (S was insufficient. In contrast, Py-GC/MS analyses simultaneously yielded molecular-level information on arsenic (As and sulfur (S together with detection of the primary ingredients of the lacquer. For this reason, it shows that several pieces of information is provided easily and quickly when the colored lacquer cultural heritage is measured using the Py-GC/MS method.

  9. Clinical applications of gas chromatography and gas chromatography-mass spectrometry of steroids

    NARCIS (Netherlands)

    Wolthers, BG; Kraan, GPB

    1999-01-01

    This review article underlines the importance of gas chromatography-mass spectrometry (GC-MS) for determination of steroids in man. The use of steroids labelled with stable isotopes as internal standard and subsequent analysis by GC-MS yields up to now the only reliable measurement of steroids in se

  10. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  11. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Feng

    2013-01-01

    Full Text Available Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  12. Analysis of Essential Oil in Jerusalem Artichoke (Helianthus tuberosus L.) Leaves and Tubers by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Helmi, Zead; Al Azzam, Khaldun Mohammad; Tsymbalista, Yuliya; Ghazleh, Refat Abo; Shaibah, Hassan; Aboul-Enein, Hassan

    2014-01-01

    Purpose: To investigate, for the first time, the chemical composition of essential oil of the tubers and leaves of Jerusalem artichoke (Helianthus tuberosus L.), a species of sunflower native to eastern North America, growing in Ukraine. Methods: A hydrodistillation apparatus was used for the extraction of volatile components and then it was analysed by gas chromatography equipped with a split-splitless injector (split ratio, 1:50) and flame ionization detector (FID). The oil was analyzed under linear temperature programming applied at 4°C/min from 50°C - 340°C. Temperatures of the injector and FID detector were maintained at 280°C and 300°C, respectively. The chemical analysis of the oil was carried out using gas chromatography coupled to mass spectrometry (GC-MS), to determine the chemical composition of the volatile fraction. Results: The essential oils content ranged from 0.00019 to 0.03486 and 0.00011 to 0.00205 (g/100g), in leaves and tubers, respectively. The qualitative and quantitative analysis led to the identification of 17 components in both species samples. The major component found in leaves and tubers was (-)-β-bisabolene with 70.7% and 63.1%, respectively. Conclusion: Essential oil profile of Jerusalem artichoke species showed significant differences between leaves and tubers species. Additionally, the leaves of Jerusalem artichoke are a promising source of natural β-bisabolene. PMID:25671184

  13. Analysis of organic acids in fruit juices by liquid chromatography-mass spectrometry: an enhanced tool for authenticity testing.

    Science.gov (United States)

    Ehling, Stefan; Cole, Shannon

    2011-03-23

    Organic acid analysis plays a fundamental role in the testing of authenticity of fruit juices. Analytical methods used routinely for organic acids suffer from poor reproducibility, often give false positives/negatives for tartaric acid, and do not offer the possibility of analyte confirmation. There are conflicting reports in the literature on the presence/absence of tartaric acid in pomegranate juice, a potential indicator of adulteration with grape juice. In this work, a method based on stable isotope dilution liquid chromatography-tandem mass spectrometry is described for citric, malic, quinic, and tartaric acid in fruit juices. Validation data including precision and recovery in six types of juice are presented. Tartaric and quinic acids were confirmed in pomegranate juice at concentrations of 1-5 and ∼1 mg/L, respectively. These concentrations are much lower than those resulting from adulteration with grape juice and apple juice, respectively, at the 5% level. A separate method for isocitric acid in orange juice based on the single standard addition method is also described.

  14. Recent applications of liquid chromatography-mass spectrometry to residue analysis of antimicrobials in food of animal origin.

    Science.gov (United States)

    Bogialli, Sara; Di Corcia, Antonio

    2009-10-01

    Residual antimicrobials in food constitute a risk to human health. Although epidemiological data on the real magnitude of their adverse effects are very scarce, they indicate that food could be an important vehicle for evolution and dissemination of antimicrobial-resistant bacteria. Public health agencies in many countries rely on detection by mass spectrometry (MS) for unambiguous identification of residues of antimicrobial agents in animal food products for human consumption. The introduction of relatively inexpensive and robust liquid chromatography (LC)-MS systems has given a strong impulse to the development of confirmatory methods for the above medicines in foodstuffs. The initial part of this review, after a brief introduction into the field of antimicrobials, is dedicated to the most important EU regulations and directives for control of residues of these substances in animal products. The main attention in this review is on the sample-treatment and MS detection systems in use today for analysing the most important classes of antimicrobials in various biological matrices (milk, animal tissues, eggs, and honey). As evidenced by this review, reversed-phase LC combined with tandem MS, usually triple-quadrupole MS (QqQMS), is currently the preferred technique in most residue analysis of a single-class of antimicrobials. A recently emerging analytical strategy is that of developing methods for detecting a large variety of veterinary drugs belonging to different classes, including pesticides (multi-class residue analysis). To do this, simple and generic extraction and separation techniques applicable to a broad range of compounds differing in physical and chemical properties have been adopted. Such methods are still based mainly on LC-QqQMS. Emerging alternative MS detection systems are time-of-flight MS, which provides accurate mass of the analyte(s), or Q-linear ion trap (IT) MS that eliminates some limitations of ITMS(n). PMID:19609510

  15. Seized cannabis seeds cultivated in greenhouse: A chemical study by gas chromatography-mass spectrometry and chemometric analysis.

    Science.gov (United States)

    Mariotti, Kristiane de Cássia; Marcelo, Marcelo Caetano Alexandre; Ortiz, Rafael S; Borille, Bruna Tassi; Dos Reis, Monique; Fett, Mauro Sander; Ferrão, Marco Flôres; Limberger, Renata Pereira

    2016-01-01

    Cannabis sativa L. is cultivated in most regions of the world. In 2013, the Brazilian Federal Police (BFP) reported 220 tons of marijuana seized and about 800,000 cannabis plants eradicated. Efforts to eradicate cannabis production may have contributed to the development of a new form of international drug trafficking in Brazil: the sending of cannabis seeds in small amounts to urban centers by logistics postal. This new and increasing panorama of cannabis trafficking in Brazil, encouraged the chemical study of cannabis seeds cultivated in greenhouses by gas-chromatography coupled with mass spectrometry (GC-MS) associated with exploratory and discriminant analysis. Fifty cannabis seeds of different varieties and brands, seized by the BFP were cultivated under predefined conditions for a period of 4.5 weeks, 5.5 weeks, 7.5 weeks, 10 weeks and 12 weeks. Aerial parts were analyzed and cannabigerol, cannabinol, cannabidiol, cannabichromene Δ9-tetrahydrocannabinol (THC) and other terpenoids were detected. The chromatographic chemical profiles of the samples were significantly different, probably due to different variety, light exposition and age. THC content increased with the age of the plant, however, for other cannabinoids, this correlation was not observed. The chromatograms were plotted in a matrix with 50 rows (samples) and 3886 columns (abundance in a retention time) and submitted to PCA, HCA and PLS-DA after pretreatment (normalization, first derivative and autoscale). The PCA and HCA showed age separation between samples however it was not possible to verify the separation by varieties and brands. The PLS-DA classification provides a satisfactory prediction of plant age.

  16. Seized cannabis seeds cultivated in greenhouse: A chemical study by gas chromatography-mass spectrometry and chemometric analysis.

    Science.gov (United States)

    Mariotti, Kristiane de Cássia; Marcelo, Marcelo Caetano Alexandre; Ortiz, Rafael S; Borille, Bruna Tassi; Dos Reis, Monique; Fett, Mauro Sander; Ferrão, Marco Flôres; Limberger, Renata Pereira

    2016-01-01

    Cannabis sativa L. is cultivated in most regions of the world. In 2013, the Brazilian Federal Police (BFP) reported 220 tons of marijuana seized and about 800,000 cannabis plants eradicated. Efforts to eradicate cannabis production may have contributed to the development of a new form of international drug trafficking in Brazil: the sending of cannabis seeds in small amounts to urban centers by logistics postal. This new and increasing panorama of cannabis trafficking in Brazil, encouraged the chemical study of cannabis seeds cultivated in greenhouses by gas-chromatography coupled with mass spectrometry (GC-MS) associated with exploratory and discriminant analysis. Fifty cannabis seeds of different varieties and brands, seized by the BFP were cultivated under predefined conditions for a period of 4.5 weeks, 5.5 weeks, 7.5 weeks, 10 weeks and 12 weeks. Aerial parts were analyzed and cannabigerol, cannabinol, cannabidiol, cannabichromene Δ9-tetrahydrocannabinol (THC) and other terpenoids were detected. The chromatographic chemical profiles of the samples were significantly different, probably due to different variety, light exposition and age. THC content increased with the age of the plant, however, for other cannabinoids, this correlation was not observed. The chromatograms were plotted in a matrix with 50 rows (samples) and 3886 columns (abundance in a retention time) and submitted to PCA, HCA and PLS-DA after pretreatment (normalization, first derivative and autoscale). The PCA and HCA showed age separation between samples however it was not possible to verify the separation by varieties and brands. The PLS-DA classification provides a satisfactory prediction of plant age. PMID:26746824

  17. Characterization of Penicillium species isolated from grape berries by their internal transcribed spacer (ITS1) sequences and by gas chromatography-mass spectrometry analysis of geosmin production.

    Science.gov (United States)

    La Guerche, Stéphane; Garcia, Carole; Darriet, Philippe; Dubourdieu, Denis; Labarère, Jacques

    2004-06-01

    Geosmin (trans-1,10-dimethyl-trans-9-decalol), an earthy-musty compound, has been identified in wines and in grape juice, in which its presence is highly detrimental to the aromatic quality. Geosmin has a biological origin, and the analysis of rotten grape microflora has been done on two grape varieties (Semillon, Cabernet Sauvignon) from six parcels of the Bordeaux region over 3 years (1999, 2000, 2001). Forty-three Penicillium-related species have been analyzed by gas chromatography-mass spectrometry (GC-MS) for their geosmin production. GC-MS analysis has demonstrated that the earthy odor was always correlated with the presence of geosmin. Phenotypic characterization of Penicillium spp. being ambiguous, a molecular characterization by rDNA internal transcribed spacer (ITS1) sequencing was performed for all strains. The results evidenced that all strains producing geosmin belonged to only one species, P. expansum, and that the other strains, not producing geosmin, belonged to three species: P. purpurogenum, P. thomii, and Talaromyces wortmanii.

  18. Development of solid-phase microextraction followed by gas chromatography-mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke.

    Science.gov (United States)

    Ye, Qing

    2008-12-12

    In this work, a novel, simple and efficient method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed to the analysis of volatile organic chemicals (VOCs) in mainstream cigarette smoke (MCS). Using a simple home-made smoking machine device, extraction and concentration of VOCs in MCS were performed by SPME fiber, and the VOCs adsorbed on fiber were desorbed, and analyzed by GC-MS. The extraction fiber types and the desorption conditions were studied, and the method precision was also investigated. After the investigation, the optimal fiber was divinylbenzene/carboxen/polydemethylsiloxane (DVB/CAR/PDMS), and the optimal desorption condition was 250 degrees C for 3 min. The method precision was from 2% to 11%. Finally, the proposed method was tested by its application of the analysis of VOCs in MCS from 10 brands of cigarettes and one reference cigarette. A total of 70 volatile compounds were identified by the proposed method. The experimental results showed that the proposed method was a simple, rapid, reliable, and solvent-free technique for the determination of VOCs in MCS.

  19. Development of a fast extraction method and optimization of liquid chromatography-mass spectrometry for the analysis of phenolic compounds in lentil seed coats.

    Science.gov (United States)

    Mirali, Mahla; Ambrose, Stephen J; Wood, Stephen A; Vandenberg, Albert; Purves, Randy W

    2014-10-15

    A systematic set of optimization experiments was conducted to design an efficient extraction and analysis protocol for screening six different sub-classes of phenolic compounds in the seed coat of various lentil (Lens culinaris Medik.) genotypes. Different compounds from anthocyanidins, flavan-3-ols, proanthocyanidins, flavanones, flavones, and flavonols sub-classes were first optimized for use as standards for liquid chromatography mass spectrometry (LC-MS) with UV detection. The effect of maceration duration, reconstitution solvent, and extraction solvent were investigated using lentil genotype CDC Maxim. Chromatographic conditions were optimized by examining column separation efficiencies, organic composition, and solvent gradient. The results showed that a 1h maceration step was sufficient and that non-acidified solvents were more appropriate; a 70:30 acetone: water (v/v) solvent was ultimately selected. Using a Kinetex PFP column, the organic concentration, gradient, and flow rate were optimized to maximize the resolution of phenolic compounds in a short 30-min analysis time. The optimized method was applied to three lentil genotypes with different phenolic compound profiles to provide information of value to breeding programs.

  20. High performance liquid chromatography-mass spectrometry analysis of high antioxidant australian fruits with antiproliferative activity against cancer cells

    Directory of Open Access Journals (Sweden)

    Joseph Sirdaarta

    2016-01-01

    Abbreviations used: DPPH: di (phenyl- (2,4,6-trinitrophenyl iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. Ian Edwin Cock

  1. Supported liquid membrane-liquid chromatography-mass spectrometry analysis of cyanobacterial toxins in fresh water systems

    Science.gov (United States)

    Mbukwa, Elbert A.; Msagati, Titus A. M.; Mamba, Bhekie B.

    Harmful algal blooms (HABs) are increasingly becoming of great concern to water resources worldwide due to indiscriminate waste disposal habits resulting in water pollution and eutrophication. When cyanobacterial cells lyse (burst) they release toxins called microcystins (MCs) that are well known for their hepatotoxicity (causing liver damage) and have been found in eutrophic lakes, rivers, wastewater ponds and other water reservoirs. Prolonged exposure to low concentrated MCs are equally of health importance as they are known to be bioaccumulative and even at such low concentration do exhibit toxic effects to aquatic animals, wildlife and human liver cells. The application of common treatment processes for drinking water sourced from HABs infested reservoirs have the potential to cause algal cell lyses releasing low to higher amounts of MCs in finished water. Trace microcystins in water/tissue can be analyzed and quantified using Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) following solid-phase extraction (SPE) sample clean-up procedures. However, extracting MCs from algal samples which are rich in chlorophyll pigments and other organic matrices the SPE method suffers a number of drawbacks, including cartridge clogging, long procedural steps and use of larger volumes of extraction solvents. We applied a supported liquid membrane (SLM) based technique as an alternative sample clean-up method for LC-ESI-MS analysis of MCs from both water and algal cells. Four (4) MC variants (MC-RR, -YR, -LR and -WR) from lyophilized cells of Microcystis aeruginosa and water collected from a wastewater pond were identified) and quantified using LC-ESI-MS following a SLM extraction and liquid partitioning step, however, MC-WR was not detected from water extracts. Within 45 min of SLM extraction all studied MCs were extracted and pre-concentrated in approximately 15 μL of an acceptor phase at an optimal pH 2.02 of the donor phase (sample). The highest

  2. A peaklet-based generic strategy for the untargeted analysis of comprehensive two-dimensional gas chromatography mass spectrometry data sets.

    Science.gov (United States)

    Egert, Björn; Weinert, Christoph H; Kulling, Sabine E

    2015-07-31

    Comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) is a well-established key technology in analytical chemistry and increasingly used in the field of untargeted metabolomics. However, automated processing of large GC×GC-MS data sets is still a major bottleneck in untargeted, large-scale metabolomics. For this reason we introduce a novel peaklet-based alignment strategy. The algorithm is capable of an untargeted deterministic alignment exploiting a density based clustering procedure within a time constrained similarity matrix. Exploiting minimal (1)D and (2)D retention time shifts between peak modulations, the alignment is done without the need for peak merging which also eliminates the need for linear or nonlinear retention time correction procedures. The approach is validated in detail using data of urine samples from a large human metabolomics study. The data was acquired by a Shimadzu GCMS-QP2010 Ultra GC×GC-qMS system and consists of 512 runs, including 312 study samples and 178 quality control sample injections, measured within a time period of 22 days. The final result table consisted of 313 analytes, each of these being detectable in at least 75% of the study samples. In summary, we present an automated, reliable and fully transparent workflow for the analysis of large GC×GC-qMS metabolomics data sets.

  3. High-resolution gas chromatography/mass spectrometry method for characterization and quantitative analysis of ginkgolic acids in Ginkgo biloba plants, extracts, and dietary supplements.

    Science.gov (United States)

    Wang, Mei; Zhao, Jianping; Avula, Bharathi; Wang, Yan-Hong; Avonto, Cristina; Chittiboyina, Amar G; Wylie, Philip L; Parcher, Jon F; Khan, Ikhlas A

    2014-12-17

    A high-resolution gas chromatography/mass spectrometry (GC/MS) with selected ion monitor method focusing on the characterization and quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba L. plant materials, extracts, and commercial products was developed and validated. The method involved sample extraction with (1:1) methanol and 10% formic acid, liquid-liquid extraction with n-hexane, and derivatization with trimethylsulfonium hydroxide (TMSH). Separation of two saturated (C13:0 and C15:0) and six unsaturated ginkgolic acid methyl esters with different positional double bonds (C15:1 Δ8 and Δ10, C17:1 Δ8, Δ10, and Δ12, and C17:2) was achieved on a very polar (88% cyanopropyl) aryl-polysiloxane HP-88 capillary GC column. The double bond positions in the GAs were determined by ozonolysis. The developed GC/MS method was validated according to ICH guidelines, and the quantitation results were verified by comparison with a standard high-performance liquid chromatography method. Nineteen G. biloba authenticated and commercial plant samples and 21 dietary supplements purported to contain G. biloba leaf extracts were analyzed. Finally, the presence of the marker compounds, terpene trilactones and flavonol glycosides for Ginkgo biloba in the dietary supplements was determined by UHPLC/MS and used to confirm the presence of G. biloba leaf extracts in all of the botanical dietary supplements.

  4. Identification of odorants in frankincense (Boswellia sacra Flueck.) by aroma extract dilution analysis and two-dimensional gas chromatography-mass spectrometry/olfactometry.

    Science.gov (United States)

    Niebler, Johannes; Buettner, Andrea

    2015-01-01

    Frankincense has been known, traded and used throughout the ages for its exceptional aroma properties, and is still commonly used in both secular and religious settings to convey a pleasant odor. Surprisingly, the odoriferous principle(s) underlying its unique odor profile have never been published. In this study, resin samples of Boswellia sacra Flueck. from both Somalia and Oman were investigated by aroma extract dilution analysis. In a comprehensive, odor-activity guided approach both chemo-analytical and human-sensory parameters were used to identify odor active constituents of the volatile fraction of B. sacra. Among the key odorants found were α-pinene, β-myrcene, linalool, p-cresol and two unidentified sesquiterpenoids. Overall, a total of 23 odorants were detected and analyzed by gas chromatography-olfactometry and heart-cut two-dimensional gas chromatography-mass spectrometry/olfactometry. The majority of the identified odorant compounds were oxygenated monoterpenes, along with some relevant mono- and sesquiterpenes and only one diterpenoid substance. Several of these compounds were reported here for the first time as odorous constituents in B. sacra. Identifying bioactive compounds might support a better understanding with regard to the potential benefits of frankincense, for example in aromatherapy or ecclesial settings. PMID:25468535

  5. Automated resolution of chromatographic signals by independent component analysis-orthogonal signal deconvolution in comprehensive gas chromatography/mass spectrometry-based metabolomics.

    Science.gov (United States)

    Domingo-Almenara, Xavier; Perera, Alexandre; Ramírez, Noelia; Brezmes, Jesus

    2016-07-01

    Comprehensive gas chromatography-mass spectrometry (GC×GC-MS) provides a different perspective in metabolomics profiling of samples. However, algorithms for GC×GC-MS data processing are needed in order to automatically process the data and extract the purest information about the compounds appearing in complex biological samples. This study shows the capability of independent component analysis-orthogonal signal deconvolution (ICA-OSD), an algorithm based on blind source separation and distributed in an R package called osd, to extract the spectra of the compounds appearing in GC×GC-MS chromatograms in an automated manner. We studied the performance of ICA-OSD by the quantification of 38 metabolites through a set of 20 Jurkat cell samples analyzed by GC×GC-MS. The quantification by ICA-OSD was compared with a supervised quantification by selective ions, and most of the R(2) coefficients of determination were in good agreement (R(2)>0.90) while up to 24 cases exhibited an excellent linear relation (R(2)>0.95). We concluded that ICA-OSD can be used to resolve co-eluted compounds in GC×GC-MS.

  6. Analysis of trace levels of sulfonamide and tetracycline antimicrobials in groundwater and surface water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lindsey, M.E.; Meyer, M.; Thurman, E.M.

    2001-01-01

    A method has been developed for the trace analysis of two classes of antimicrobials consisting of six sulfonamides (SAs) and five tetracyclines (TCs), which commonly are used for veterinary purposes and agricultural feed additives and are suspected to leach into ground and surface water. The method used solid-phase extraction and liquid chromatography/mass spectrometry (LC/MS) with positive ion electrospray. The unique combination of a metal chelation agent (Na2EDTA) with a macroporous copolymer resulted in quantitative recoveries by solid-phase extraction (mean recovery, 98 ?? 12%) at submicrogram-per-liter concentrations. An ammonium formate/formic acid buffer with a methanol/water gradient was used to separate the antimicrobials and to optimize the signal intensity. Mass spectral fragmentation and ionization characteristics were determined for each class of compounds for unequivocal identification. For all SAs, a characteristic m/z 156 ion representing the sulfanilyl fragment was identified. TCs exhibited neutral losses of 17 amu resulting from the loss of ammonia and 35 amu from the subsequent loss of water. Unusual matrix effects were seen only for TCs in this first survey of groundwater and surface water samples from sites around the United States, requiring that TCs be quantitated using the method of standard additions.

  7. Analysis of furan in coffee of different provenance by head-space solid phase microextraction gas chromatography-mass spectrometry: effect of brewing procedures.

    Science.gov (United States)

    La Pera, Lara; Liberatore, Alfredo; Avellone, Giuseppe; Fanara, Serena; Dugo, Giacomo; Agozzino, Pasquale

    2009-06-01

    A simple, sensitive and accurate method for the analysis of furan in roasted coffee has been used based on headspace-solid-phase micro-extraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). The extraction was performed using 75-microm carboxen/polydimethylsiloxane fiber. Ionic strength, extraction time and temperature, and desorption time were assessed as the most important parameters affecting the HS-SPME procedure and d(4)-furan was used as the internal standard. The linearity range was in the range 0.0075-0.486 ng g(-1); the LOD and LOQ calculated using the signal-to-noise ratio approach were 0.002 and 0.006 ng g(-1), respectively. The inter- and intra-day precision was 8 and 10%, respectively. The concentration of furan found in batches of roasted coffee powder different producing countries ranged from 57.3 to 587.3 ng g(-1). The mean reduction in furan levels observed when brewing coffee by either infusion, using a moka pot or an expresso machine was 57, 67.5 and 63.3%, respectively. PMID:19680951

  8. Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Oh, Min-Seok; Lee, Seon-Hwa; Moon, Myeong Hee; Lee, Dong Soo; Park, Hyun-Mee

    2014-01-01

    A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standard deviations (RSDs) of 0.92-10.6% and spiked sample recoveries of 80.6-97.8% were obtained. Limits of detection for PAHs were in the range of 0.15-0.77 µg/kg and those for phthalates were in the range of 4.6-10.0 µg/kg. The calibration curves exhibited good linearities with regression coefficients of R(2) ≥ 0.99. Twelve edible oils were examined to evaluate the efficiency of this method. Among the 12 analytes, dibutyl phthalates (DBP), diethylhexyl phthalates (DEHP), diethylhexyl adipate (DEHA), benzo[a]anthracene (B[a]A), chrysene (Chry) and benzo[b]fluoranthene (B[b]F) were detected in the range of 1.17-806 µg/kg.

  9. Signal and Charge Enhancement for Protein Analysis by Liquid Chromatography-Mass Spectrometry with Desorption Electrospray Ionization

    OpenAIRE

    Liu, Yan; Miao, Zhixin; Lakshmanan, Rajeswari; Ogorzalek Loo, Rachel R.; Loo, Joseph A.; Chen, Hao

    2012-01-01

    We recently reported the use of desorption electrospray ionization (DESI) as a novel interface to couple high-performance liquid chromatography (HPLC) with mass spectrometry (MS) (Chem. Commun. 2011, 47, 4171). One of the benefits of such an interface is that post-column derivatization of separated analytes can be integrated with ionization via a “reactive” DESI approach in which a derivatizing reagent is doped into the spray solvent. The reactive DESI interface allows analyte desorption/ioni...

  10. Ion chromatography-mass spectrometry: a review of recent technologies and applications in forensic and environmental explosives analysis.

    Science.gov (United States)

    Barron, Leon; Gilchrist, Elizabeth

    2014-01-01

    The development and application of ion chromatography (IC) coupled to mass spectrometry (MS) is discussed herein for the quantitative determination of low-order explosives-related ionic species in environmental and forensic sample types. Issues relating to environmental explosives contamination and the need for more confirmatory IC-MS based applications in forensic science are examined. In particular, the compatibility of a range of IC separation modes with MS detection is summarised along with the analytical challenges that have been overcome to facilitate determinations at the ng-μg L(-1) level. Observed trends in coupling IC to inductively coupled plasma and electrospray ionisation mass spectrometry form a particular focus. This review also includes a discussion of the relative performance of reported IC-MS methods in comparison to orthogonal ion separation-based, spectrometric and spectroscopic approaches to confirmatory detection of low-order explosives. Finally, some promising areas for future research are highlighted and discussed with respect to potential IC-MS applications.

  11. Extraction of essential oil from shaddock peel and analysis of its components by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Essential oil, with more than thirty kinds of compounds separated and identified by gas chromatographymass spectrometry, was extracted from Shatian shaddock peel and Sweet shaddock peel by squeeze-steam distillation and direct steam distillation method. Among their composition, the main components are terpene compounds, which account for 93. 926% (mass fraction, the same below) and 85. 843% of essential oils extracted from Shatian shaddock peel and Sweet shaddock peel, respectively. Although nootkatone is the major contributor of shaddock characteristic scent, and its contents are 1. 069 % and 1. 749 % of essential oils from Sweet shaddock peel and Shatian shaddock peel, respectively. The results show that squeeze-steam distillation gives higher yield and good quality of essential oil and the compositions of essential oils from two kinds of shaddock peels are different, but the main contributors of the shaddock scent are the same.

  12. Field Analysis of Polychlorinated Biphenyls (PCBs) in Soil Using Solid-Phase Microextraction (SPME) and a Portable Gas Chromatography-Mass Spectrometry System.

    Science.gov (United States)

    Zhang, Mengliang; Kruse, Natalie A; Bowman, Jennifer R; Jackson, Glen P

    2016-05-01

    An expedited field analysis method was developed for the determination of polychlorinated biphenyls (PCBs) in soil matrices using a portable gas chromatography-mass spectrometry (GC-MS) instrument. Soil samples of approximately 0.5 g were measured with a portable scale and PCBs were extracted by headspace solid-phase microextraction (SPME) with a 100 µm polydimethylsiloxane (PDMS) fiber. Two milliliters of 0.2 M potassium permanganate and 0.5 mL of 6 M sulfuric acid solution were added to the soil matrices to facilitate the extraction of PCBs. The extraction was performed for 30 min at 100 ℃ in a portable heating block that was powered by a portable generator. The portable GC-MS instrument took less than 6 min per analysis and ran off an internal battery and helium cylinder. Six commercial PCB mixtures, Aroclor 1016, 1221, 1232, 1242, 1248, 1254, and 1260, could be classified based on the GC chromatograms and mass spectra. The detection limit of this method for Aroclor 1260 in soil matrices is approximately 10 ppm, which is sufficient for guiding remediation efforts in contaminated sites. This method was applicable to the on-site analysis of PCBs with a total analysis time of 37 min per sample. However, the total analysis time could be improved to less than 7 min per sample by conducting the rate-limiting extraction step for different samples in parallel. PMID:27170778

  13. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; Smalling, Kelly L.; Kuivila, Kathryn M.

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  14. Improved detection of multiple environmental antibiotics through an optimized sample extraction strategy in liquid chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi

    2015-12-01

    A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.

  15. Separation of Caffeine from Beverages and Analysis Using Thin-Layer Chromatography and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Torres y Torres, Janelle L.; Hiley, Shauna L.; Lorimor, Steven P.; Rhoad, Jonathan S.; Caldwell, Benjamin D.; Zweerink, Gerald L.; Ducey, Michael

    2015-01-01

    The Characterization and Analysis of a Product (CAP) project is used to introduce first-semester general chemistry students to chemical instrumentation through the analysis of caffeine-containing beverage products. Some examples of these products have included coffee, tea, and energy drinks. Students perform at least three instrumental experiments…

  16. Rapid enzymatic hydrolysis of masked deoxynivalenol and zearalenone prior to liquid chromatography mass spectrometry or immuniassay analysis

    NARCIS (Netherlands)

    Nielen, M.W.F.; Weijers, C.A.G.M.; Peters, J.; Weignerová, L.; Zuilhof, H.; Franssen, M.C.R.

    2014-01-01

    Recently it has been shown that conjugates (‘masked mycotoxins’) may contribute to the total daily intake of hazardous mycotoxins. Therefore, there is an urgent need for rapid analysis methods that assess the level of both free and masked mycotoxins in food and feed. However, the analysis of masked

  17. Dispersive micro solid-phase extraction for the rapid analysis of synthetic polycyclic musks using thermal desorption gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chung, Wu-Hsun; Tzing, Shin-Hwa; Ding, Wang-Hsien

    2013-09-13

    A simple and solvent-free method for the rapid analysis of five synthetic polycyclic musks in water samples is described. The method involves the use of dispersive micro solid-phase extraction (D-μ-SPE) coupled with direct thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) operating in the selected-ion-storage (SIS) mode. The parameters affecting the extraction efficiency of the target analytes from water sample and the thermal desorption conditions in the GC injection-port were optimized using a central composite design method. The optimal extraction conditions involved immersing 3.2mg of a typical octadecyl (C18) bonded silica adsorbent (i.e., ENVI-18) in a 10mL water sample. After extraction by vigorously shaking for 1.0min, the adsorbents were collected and dried on a filter. The adsorbents were transferred to a micro-vial, which was directly inserted into GC temperature-programmed injector, and the extracted target analytes were then thermally desorbed in the GC injection-port at 337°C for 3.8min. The limits of quantitation (LOQs) were determined to be 1.2-3.0ng/L. Precision, as indicated by relative standard deviations (RSDs), was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 and 90%. A preliminary analysis of the river water samples revealed that galaxolide (HHCB) and tonalide (AHTN) were the two most common synthetic polycyclic musks present. Using a standard addition method, their concentrations were determined to in the range from 11 to 140ng/L.

  18. Headspace analysis of volatile metabolites of Pseudomonas aeruginosa and related species by gas chromatography-mass spectrometry.

    OpenAIRE

    Labows, J N; McGinley, K J; Webster, G F; Leyden, J J

    1980-01-01

    Gas chromatographic-mass spectrometric analysis of headspace volatiles was performed on cultures of 11 strains of Pseudomonas aeruginosa and 1 strain each of Pseudomonas cepacia, Pseudomonas putida, Pseudomonas putrefaciens, Pseudomonas fluorescens, and Pseudomonas maltophilia. All strains of Pseudomonas aeruginosa produced a distinctive series of odd-carbon methyl ketones, particularly 2-nonanone and 2-undecanone, and 2-aminoacetophenone. The other strains failed to produce 2-aminoacetopheno...

  19. Simultaneous analysis of pesticides from different chemical classes by using a derivatisation step and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Raeppel, Caroline; Nief, Marie; Fabritius, Marie; Racault, Lucie; Appenzeller, Brice M; Millet, Maurice

    2011-11-01

    This work presents a new method to analyse simultaneously by GC-MS 31 pesticides from different chemical classes (2,4 D, 2,4 MCPA, alphacypermethrin, bifenthrin, bromoxynil, buprofezin, carbaryl, carbofuran, clopyralid, cyprodinil, deltamethrin dicamba, dichlobenil, dichlorprop, diflufenican, diuron, fenoxaprop, flazasulfuron, fluroxypyr, ioxynil, isoxaben, mecoprop-P, myclobutanil, oryzalin, oxadiazon, picloram, tau-fluvalinate tebuconazole, triclopyr, trifluralin and trinexapac-p-ethyl). This GC-MS method will be applied to the analysis of passive samplers (Tenax(®) tubes and SPME fiber) used for the evaluation of the indoor and outdoor atmospheric contamination by non-agricultural pesticides. The method involves a derivatisation step for thermo-labile or polar pesticides. Different agents were tested and MtBSTFA (N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide), a sylilation agent producing very specific fragments [M-57], was retained. However, diuron could not be derivatised and the isocyanate product was used for identification and quantification. Pesticides which did not need a derivatisation step were not affected by the presence of the derivatisation agent and they could easily be analysed in mixture with derivatised pesticides. The method can be coupled to a thermal-desorption unit or to SPME extraction for a multiresidue analysis of various pesticides in atmospheric samples. PMID:21962330

  20. Analysis of iodide and iodate in Lake Mead, Nevada using a headspace derivatization gas chromatography-mass spectrometry.

    Science.gov (United States)

    Dorman, James W; Steinberg, Spencer M

    2010-02-01

    We report here a derivatization headspace method for the analysis of inorganic iodine in water. Samples from Lake Mead, the Las Vegas Wash, and from Las Vegas tap water were examined. Lake Mead and the Las Vegas Wash contained a mixture of both iodide and iodate. The average concentration of total inorganic iodine (TII) for Lake Mead was approximately 90 nM with an iodide-to-iodate ratio of approximately 1. The TII concentration (approximately 160 nM) and the ratio of iodide to iodate were higher for the Las Vegas Wash (approximately 2). The TII concentration for tap water was close to that of Lake Mead (approximately 90 nM); however, tap water contained no detectable iodide as a result of ozonation and chlorine treatment which converts all of the iodide to iodate. PMID:19184627

  1. Pyrolysis-gas chromatography/mass spectrometry analysis as a useful tool in forensic examination of automotive paint traces.

    Science.gov (United States)

    Zieba-Palus, Janina; Zadora, Grzegorz; Milczarek, Jakub M; Kościelniak, Paweł

    2008-01-25

    Pyrolysis (Py)-GC/MS was applied in comparative analysis of polymer binder of 150 automobile clearcoat samples. It was found that binders of identical type and similar infrared spectra can be, in most cases, effectively differentiated, sometimes based only on the presence of peaks of very low intensity originating from minor paint components. The qualitative procedure of pyrograms comparison was developed. The results obtained, enable one to draw the conclusion that Py-GC/MS appears as valuable, very informative analytical technique of car paint samples examination. Providing identification of paint pyrolysis products, it enables discrimination of samples on the basis of their composition. However, in some cases, paint samples were still indistinguishable on the basis of their pyrograms. PMID:17931635

  2. Analysis of Mammalian Cell Proliferation and Macromolecule Synthesis Using Deuterated Water and Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Victoria C. Foletta

    2016-10-01

    Full Text Available Deuterated water (2H2O, a stable isotopic tracer, provides a convenient and reliable way to label multiple cellular biomass components (macromolecules, thus permitting the calculation of their synthesis rates. Here, we have combined 2H2O labelling, GC-MS analysis and a novel cell fractionation method to extract multiple biomass components (DNA, protein and lipids from the one biological sample, thus permitting the simultaneous measurement of DNA (cell proliferation, protein and lipid synthesis rates. We have used this approach to characterize the turnover rates and metabolism of a panel of mammalian cells in vitro (muscle C2C12 and colon cancer cell lines. Our data show that in actively-proliferating cells, biomass synthesis rates are strongly linked to the rate of cell division. Furthermore, in both proliferating and non-proliferating cells, it is the lipid pool that undergoes the most rapid turnover when compared to DNA and protein. Finally, our data in human colon cancer cell lines reveal a marked heterogeneity in the reliance on the de novo lipogenic pathway, with the cells being dependent on both ‘self-made’ and exogenously-derived fatty acid.

  3. Analysis of major congeners of polybromobiphenyls and polybromodiphenyl ethers in office dust using high resolution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kefeni, Kebede K; Okonkwo, Jonathan O

    2012-05-01

    The study focused on analysis of polybromobiphenyls (PBBs) and polybromodiphenyl ethers (PBDEs) congeners in office dust obtained in Pretoria, South Africa. Of the 32 congeners considered for identification, (BB-1, 2, 4, 10, 15, 26, 29, 30, 31, 38, 49, 80, 103, 153, 155, 209 and BDE-3, 15, 17, 28, 47, 66, 77, 85, 99, 100, 126, 138, 153, 154, 183, 209) only BB-2, 4, 30, 153, 209 and BDE-47, 66, 85, 99, 153 and 209 congeners were detected. The sum of PBBs concentration detected in office dust ranged from

  4. Molecularly imprinted solid phase extraction using stable isotope labeled compounds as template and liquid chromatography-mass spectrometry for trace analysis of bisphenol A in water sample

    International Nuclear Information System (INIS)

    We have developed a molecularly imprinted polymer (MIP) using a stable isotope labeled compound as the template molecule and called it the ''isotope molecularly imprinted polymer'' (IMIP). In this study, bisphenol A (BPA) was used as the model compound. None imprinted polymer (NIP), MIP, dummy molecularly imprinted polymer (DMIP) and IMIP were prepared by the suspension polymerization method using without template, BPA, 4-tert-butylphenol (BP) and bisphenol A-d16 (BPA-d16), respectively. The polymers were subjected to molecularly imprinted solid phase extraction (MI-SPE), and the extracted samples were subjected to liquid chromatography-mass spectrometry (LC-MS). Although the leakage of BPA-d16 from the IMIP was observed and that of BPA was not observed. The selectivity factors of MIP and IMIP for BPA were 4.45 and 4.43, respectively. Therefore, IMIP had the same molecular recognition ability as MIP. When MI-SPE with IMIP was used and followed by LC-MS in the analysis of river water sample, the detection limit of BPA was 1 ppt with high sensitivity. Moreover, the average recovery was higher than 99.8% (R.S.D.: 3.7%) by using bisphenol A-13C12 (BPA-13C12) as the surrogate standard. In addition, the IMIP were employed in MI-SPE of BPA in river water sample by LC-MS. The concentration of BPA in the river water sample was determined to be 32 pg ml-1. We confirmed that it was possible to measure trace amounts of a target analyte by MI-SPE using IMIP

  5. Validation of an isotope dilution gas chromatography-mass spectrometry method for combined analysis of oxysterols and oxyphytosterols in serum samples.

    Science.gov (United States)

    Schött, Hans-Frieder; Lütjohann, Dieter

    2015-07-01

    We describe the validation of a method for the analysis of oxysterols, i.e. oxycholesterols and oxyphytosterols, in human serum using gas chromatography-mass spectrometry selected ion monitoring (GC-MS-SIM). Concentrations of 7α- and 7β-hydroxy-, and 7oxo-cholesterol, -campesterol, and -sitosterol as well as 4β-hydroxycholesterol and side-chain oxygenated 24S-, 25-, and 27-hydroxycholesterol were determined by isotope dilution methodology. After saponification at room temperature the oxysterols were extracted, separated from their substrates, cholesterol, campesterol, and sitosterol, by solid phase extraction, and subsequently derivatised to their corresponding trimethylsilyl-ethers prior to GC-MS-SIM. In order to prevent artificial autoxidation butylated hydroxytoluene and ethylenediaminetetraacetic acid were added. The validation of the method was performed according to the International Conference on Harmonisation guidance, including limits of detection and quantification, ranges, recovery and precision. Due to improved instrumental settings and work-up procedure, limits of detection and quantification ranged between 8.0-202.0pg/mL and 28.0-674pg/mL, respectively. Recovery data in five calibration points varied between 91.9% and 116.8% and in serum samples between 93.1% and 118.1%. The mean coefficient of variation (CV) for the recovery of all compounds was <10%. Well satisfying CVs for within-day precision (2.1-10.8%) and for between-day precision (2.3-12.1%) were obtained. More than 20 samples could be processed in a single routine day and test series of about 300 samples can be realised without impairment of the validation parameters during a sequence. Comparison of oxysterol and oxyphytosterol content in serum and plasma revealed no difference. A fully validated isotope dilution methodology for the quantification of oxycholesterols and oxyphytosterols from human serum or plasma is presented. PMID:25701095

  6. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Michaela Vieriková

    2010-07-01

    Full Text Available  Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS. Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detection and limit of quantification for acrylamide were 7 µg.kg-1 and 20 µg.kg-1 by GC-MS, 9 µg.kg-1  and 30 µg.kg-1 by UPLC-MS. For both methods the reproducibility, given as relative standard deviation was    doi:10.5219/61  

  7. Urinary metabonomics study in a rat model in response to protein-energy malnutrition by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wu, Zeming; Li, Min; Zhao, Chunxia; Zhou, Jia; Chang, Yuwei; Li, Xiang; Gao, Peng; Lu, Xin; Li, Yousheng; Xu, Guowang

    2010-11-01

    Systematic studies were performed on the biological perturbations in metabolic phenotype responding to protein-energy malnutrition through global metabolic profiling analysis, in combination with pattern recognition. The malnutrition rat model was established through five weeks of strict diet restriction, and the metabonome data obtained from gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) were integrated to approximate the comprehensive metabolic signature. Principal component analysis and orthogonal projection to latent structure analysis were used for the classification of metabolic phenotypes and discovery of differentiating metabolites. The perturbations in the urine profiles of malnourished rats were marked by higher levels of creatine, threitol, pyroglutamic acid, gluconic acid and kynurenic acid, as well as decreased levels of succinic acid, cis-aconitic acid, citric acid, isocitric acid, threonic acid, trimethylglycine, N-methylnicotinic acid and uric acid. The alterations in these metabolites were associated with perturbations in energy metabolism, carbohydrate, amino acid, and fatty acid metabolism, purine metabolism, cofactor and vitamin metabolism, in response to protein and energy malnutrition. Our findings show the integration of GC-MS and LC-MS techniques for untargeted metabolic profiling analysis was promising for nutriology. PMID:20717558

  8. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography

    Science.gov (United States)

    Liu, Cui-ting; Zhang, Min; Yan, Ping; Liu, Hai-chan; Liu, Xing-yun; Zhan, Ruo-ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R2 ≥ 0.9992), precision (RSD protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs. PMID:26904360

  9. Analysis of chemical warfare agents in organic liquid samples with magnetic dispersive solid phase extraction and gas chromatography mass spectrometry for verification of the chemical weapons convention.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud, Raghavender D; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-05-27

    A simple, sensitive and low temperature sample preparation method is developed for detection and identification of Chemical Warfare Agents (CWAs) and scheduled esters in organic liquid using magnetic dispersive solid phase extraction (MDSPE) followed by gas chromatography-mass spectrometry analysis. The method utilizes Iron oxide@Poly(methacrylic acid-co-ethylene glycol dimethacrylate) resin (Fe2O3@Poly(MAA-co-EGDMA)) as sorbent. Variants of these sorbents were prepared by precipitation polymerization of methacrylic acid-co-ethylene glycol dimethacrylate (MAA-co-EGDMA) onto Fe2O3 nanoparticles. Fe2O3@poly(MAA-co-EGDMA) with 20% MAA showed highest recovery of analytes. Extractions were performed with magnetic microspheres by MDSPE. Parameters affecting the extraction efficiency were studied and optimized. Under the optimized conditions, method showed linearity in the range of 0.1-3.0μgmL(-1) (r(2)=0.9966-0.9987). The repeatability and reproducibility (relative standard deviations (RSDs) %) were in the range of 4.5-7.6% and 3.4-6.2% respectively for organophosphorous esters in dodecane. Limits of detection (S/N=3/1) and limit of quantification (S/N=10/1) were found to be in the range of 0.05-0.1μgmL(-1) and 0.1-0.12μgmL(-1) respectively in SIM mode for selected analytes. The method was successfully validated and applied to the extraction and identification of targeted analytes from three different organic liquids i.e. n-hexane, dodecane and silicon oil. Recoveries ranged from 58.7 to 97.3% and 53.8 to 95.5% at 3μgmL(-1) and 1μgmL(-1) spiking concentrations. Detection of diethyl methylphosphonate (DEMP) and O-Ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) in samples provided by the Organization for Prohibition of Chemical Weapons Proficiency Test (OPCW-PT) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals. PMID:27113675

  10. Analysis of volatile organic compounds in Turf by Gas Chromatography-Mass Spectrometry%泥碳中有机挥发物的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    王玲; 贾益群; 陈刚

    2004-01-01

    The volatile organic compounds have been separated from the sample in Northeast turf, and these were characterized by gas chromatography-mass spectrometry (GC/MS). 42 compounds were identified using GC/MS library search.

  11. Advances in Application of Chromatography and Chromatography- Mass Spectrometry in Analysis of Traditional Chinese Medicine%色谱及色谱-质谱联用技术在中药分析中的应用进展

    Institute of Scientific and Technical Information of China (English)

    张晶; 杨海龙; 臧恒昌

    2013-01-01

    The advances in the application of chromatography and chromatography- mass spectrometry in the analysis of traditional Chinese medicine (TCM) are reviewed in this paper. Characteristics, range of application and research status of each method are elaborated, which aim to provide reference for TCM researchers.%  对色谱及其质谱联用技术在中药领域的应用进展做一综述,阐述了各方法的特点、应用范围及研究现状,旨在为中药研究工作者提供参考依据。

  12. Assessment of the metabolic chiral inversion of D-leucine in rat by gas chromatography-mass spectrometry combined with a stable isotope dilution analysis.

    Science.gov (United States)

    Hasegawa, H; Matsukawa, T; Shinohara, Y; Hashimoto, T

    2000-08-01

    The stereoselective pharmacokinetics of leucine enantiomers in rats has been investigated to evaluate the inversion of D-leucine to L-enantiomer. After a bolus i.v. administration of D- or L-[2H7]leucine to rats, blood samples were obtained over 6 h after administration and analyzed by a stereoselective gas chromatography-mass spectrometry method. Racemic [2H3]leucine was used as an internal standard. The method involved methyl esterification and subsequent chiral derivatization with (+)-alpha-methoxy-alpha-trifluoromethylphenylacetyl chloride to form the diastereomeric amide. The derivatization made possible the separation of leucine enantiomers with good gas chromatographic behavior. Plasma concentration of both D- and L-[2H7]leucine declined biexponentially, with elimination half-lives of 60 and 14 min, respectively. In contrast to the L-enantiomer, the D-enantiomer had a lower systemic clearance. When D-[2H7]leucine was administered, the L-enantiomer was found to rapidly appear in plasma. About 30% of an administered dose of the D-isomer was stereospecifically inverted to the L-enantiomer. There was no measurable inversion of the L- to D-enantiomer. This methodology has made it possible to evaluate the pharmacokinetics of each enantiomer of amino acids and estimate of chiral inversion after administration of D-amino acids. PMID:10901701

  13. Trace analysis of chlorophenols in river water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, M.; Ishii, Y.; Okanouchi, N.; Sakui, N.; Ito, R.; Inoue, K.; Nakazawa, H. [Hoshi Univ., Tokyo (Japan). Dept. of Analytical Chemistry, Faculty of Pharmaceutical Sciences; Saito, K. [Saitama Institute of Public Health, Saitama (Japan). Dioxin Research Group

    2004-09-15

    Many analytical methods for the determination of chlorophenols in water samples have been reported including gas chromatography-mass spectrometry (GC-MS). However, GC-MS was initially used for the determination of phenol compounds even though derivatization was required. The derivatization leads to sharper peaks and hence to better separation and higher sensitivity for the phenols. However, the derivatization faces the risk of contamination and hence an overestimation of chlorophenols concentration. In order to overcome these problems, in situ derivatization has been developed, which involves the simple addition of a reagent to a liquid sample. Recently, a new sorptive extraction technique that uses a stir bar coated with polydimethylsiloxane (PDMS) was developed. The technique is known as stir bar sorptive extraction (SBSE). We already reported that determination of 4-tert-octylphenol (OP) and 4-nonylphenol (NP) in river water4 and body fluid samples by using SBSE. In addition, SBSE with in situ derivatization has been successfully used in the determination of bisphenol A (BPA) in human body fluid samples6 and phenolic xenoestrogens in river water samples. The aim of this study is to determine trace amounts of chlorophenols in water samples by SBSE with in situ derivatization, followed by thermal desorption (TD)-GC-MS. The developed method was applied to determination of chlorophenols in river water samples.

  14. Multiclass pesticide analysis in fruit-based baby food: A comparative study of sample preparation techniques previous to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Petrarca, Mateus H; Fernandes, José O; Godoy, Helena T; Cunha, Sara C

    2016-12-01

    With the aim to develop a new gas chromatography-mass spectrometry method to analyze 24 pesticide residues in baby foods at the level imposed by established regulation two simple, rapid and environmental-friendly sample preparation techniques based on QuEChERS (quick, easy, cheap, effective, robust and safe) were compared - QuEChERS with dispersive liquid-liquid microextraction (DLLME) and QuEChERS with dispersive solid-phase extraction (d-SPE). Both sample preparation techniques achieved suitable performance criteria, including selectivity, linearity, acceptable recovery (70-120%) and precision (⩽20%). A higher enrichment factor was observed for DLLME and consequently better limits of detection and quantification were obtained. Nevertheless, d-SPE provided a more effective removal of matrix co-extractives from extracts than DLLME, which contributed to lower matrix effects. Twenty-two commercial fruit-based baby food samples were analyzed by the developed method, being procymidone detected in one sample at a level above the legal limit established by EU. PMID:27374564

  15. Pathway confirmation and flux analysis of central metabolic pathways in Desulfovibrio vulgaris Hildenborough using Gas Chromatography-Mass Spectrometry and Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry

    International Nuclear Information System (INIS)

    Flux distribution in central metabolic pathways of Desulfovibrio vulgaris Hildenborough was examined using 13C tracer experiments. Consistent with the current genome annotation and independent evidence from enzyme activity assays, the isotopomer results from both GC-MS and Fourier Transform-Ion Cyclotron Resonance mass spectrometry (FT-ICR MS) indicate the lack of oxidatively functional TCA cycle and an incomplete pentose phosphate pathway. Results from this study suggest that fluxes through both pathways are limited to biosynthesis. The data also indicate that >80 percent of the lactate was converted to acetate and the reactions involved are the primary route of energy production (NAD(P)H and ATP production). Independent of the TCA cycle, direct cleavage of acetyl-CoA to CO and 5,10-methyl-THF also leads to production of NADH and ATP. Although the genome annotation implicates a ferredoxin-dependent oxoglutarate synthase, isotopic evidence does not support flux through this reaction in either the oxidative or reductive mode; therefore, the TCA cycle is incomplete. FT-ICR MS was used to locate the labeled carbon distribution in aspartate and glutamate and confirmed the presence of an atypical enzyme for citrate formation suggested in previous reports (the citrate synthesized by this enzyme is the isotopic antipode of the citrate synthesized by the (S)-citrate synthase). These findings enable a better understanding of the relation between genome annotation and actual metabolic pathways in D. vulgaris, and also demonstrate FT-ICR MS as a powerful tool for isotopomer analysis, overcoming problems in both GC-MS and NMR spectroscopy

  16. Screening for N-glycosylated proteins by liquid chromatography mass spectrometry

    DEFF Research Database (Denmark)

    Bunkenborg, Jakob; Pilch, Bartosz J; Podtelejnikov, Alexandre V;

    2004-01-01

    in complex mixtures by reducing sample complexity and enriching glycoprotein content. Glycosylated proteins are selected by an initial lectin chromatography step and digested with endoproteinase Lys-C. Glycosylated peptides are then selected from the digest mixture by a second lectin chromatography step....... The glycan components are removed with N-glycosidase F and the peptides digested with trypsin before analysis by on-line reversed-phase liquid chromatography mass spectrometry. Using two different lectins, concanavalin A and wheat germ agglutinin, this procedure was applied to human serum and a total of 86 N...

  17. The bridge between thin layer chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry: The realization of liquid thin layer chromatography-mass spectrometry (LTLC-MS).

    Science.gov (United States)

    Li, Yafeng; Wang, Jianing; Zhan, Lingpeng; Wleklinski, Michael; Wang, Jiyun; Xiong, Caiqiao; Liu, Huihui; Zhou, Yueming; Nie, Zongxiu

    2016-08-19

    The combination of thin layer chromatography (TLC) and mass spectrometry (MS) has been studied for decades, but for most cases MS detection is done after TLC separation is finished. Here, an online simultaneous TLC-MS analysis system, liquid thin layer chromatography-mass spectrometry (LTLC-MS), is developed which successfully synchronize TLC separation process and MS detection process like GC-MS and HPLC-MS do. And there's no need to use specially designed TLC, just regular TLC plates are enough. LTLC-MS method is composed of a newly developed ambient ionization method, glow discharge-matrix assisted infrared desorption ionization (GD-MAIRDI), and forced-flow TLC (FFTLC) technique, which guarantees the MS detection process does not disturb the TLC separation process throughout the whole analysis. The whole LTLC-MS analysis only need two steps and less than 15min. Mixtures as well as the two main components of a pain relief pills have been successfully analyzed by LTLC-MS. This proof of concept study opens up new possibilities of combining TLC with MS, and will further broaden the application abilities of TLC. PMID:27452991

  18. Gas chromatography mass spectrometry : key technology in metabolomics

    NARCIS (Netherlands)

    Koek, Maud Marijtje

    2009-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues. Gas chromatography coupled to mass spectrometry (GC-MS) is very suitable for metabolomics analysis, as it combines high separation power with sensiti

  19. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  20. Evaluation of Costus afer Ker Gawl. in vitro anti-inflammatory activity and its chemical constituents identiifed using gas chromatography-mass spectrometry analysis

    Institute of Scientific and Technical Information of China (English)

    Godswill Nduka Anyasor; Onajobi Funmilayo; Osilesi Odutola; Adebawo Olugbenga; Efere Martins Oboutor

    2015-01-01

    Objective:To evaluate the anti-inflammatory activity of a tropical African medicinal plant, Costus afer (C. afer) Ker Gawl. in vitro and identify the chemical constituents in the most active fraction. Methods:Hexane, ethyl acetate, n-butanol and aqueous fractions obtained through successive solvent partitioning of 70%methanolic leaf or stem extracts of C. afer were subjected to in vitro anti-inflammatory screening assays viz. anti-denaturation of protein, stabilization of human red blood cell (HRBC) membrane against hypotonicity-induced hemolysis and anti-proteinase activities. Diclofenac sodium was used as a standard drug. The chemical compounds in the most active fraction were determined using quantitative phytochemical and gas chromatography-mass spectrometry (GC/MS) analytical methods, comparing the mass spectra of the GC/MS identified compounds with those of the National Institute of Standards and Technology (NIST) database library. Results:The hexane fraction of C. afer leaf (HFCAL) with an IC50 of 33.36μg/mL, 33μg/mL and 212.77 μg/mL exhibited the highest anti-denaturation of protein, stabilization of HRBC membrane and anti-proteinase activities respectively when compared with other test fractions. The GC/MS identified compounds in HFCAL known to possess anti-inflammatory property were terpenoids (naphthalene 1,6-dimethyl-; naphthalene 2,3-dimethyl-; phytol), phenol [phenol 2,4-bis(1,1-dimethylethyl)], coumaran [2(4H)-benzofuranone, 5,6,7,7a-tetrahydro-4, 4,7atrimethyl and fatty acids (pentadecanoic acid;hexadecanoic acid;n-hexadecanoic acid;9,12-octadecanoic acid-methyl ester;9,12,15 octadecatrienoic acid and cis-vaccenic acid)]. Conclusion: Therefore, HFCAL could be considered as a potential source of anti-inflammatory agents for herbal formulation or pharmaceutical drug production.

  1. Methods of analysis by the U. S. Geological Survey National Water Quality Laboratory - determination of organonitrogen herbicides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Sandstrom, Mark W.; Wydoski, Duane S.; Schroeder, Michael P.; Zamboni, Jana L.; Foreman, William T.

    1992-01-01

    A method for the isolation of organonitrogen herbicides from natural water samples using solid-phase extraction and analysis by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction cartridges containing octadecyl-bonded porous silica to remove the herbicides. The cartridges are dried using carbon dioxide, and adsorbed herbicides are removed from the cartridges by elution with 1.8 milliliters of hexaneisopropanol (3:1). Extracts of the eluants are analyzed by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of at least three characteristic ions. The method detection limits are dependent on sample matrix and each particular herbicide. The method detection limits, based on a 100-milliliter sample size, range from 0.02 to 0.25 microgram per liter. Recoveries averaged 80 to 115 percent for the 23 herbicides and 2 metabolites in 1 reagent-water and 2 natural-water samples fortified at levels of 0.2 and 2.0 micrograms per liter.

  2. Quantitative analysis of trace levels ofβ-ionone in water by liquid-liquid- phase extraction-gas chromatography-mass spectrometry (LLE-GC-MS)

    Institute of Scientific and Technical Information of China (English)

    高梦鸿; 高乃云; 谢茴茴; 安娜; 邓扬; 戎文磊

    2015-01-01

    A simple and rapid technique based on liquid−liquid extraction coupled to gas chromatography-mass spectrometric detection (LLE-GC-MS) was developed for analysis of taste and odour compoundβ-ionone in water. Instrument parameters including programmed oven temperature, injection temperature and ion source temperature were evaluated and optimized. Effects of extraction time, ionic strength and pH on the detection efficiency were investigated and optimum conditions were 8 min of extraction time, without NaCl addition at pH=9. Good linearity (R2=0.9997) was obtained when the linear range was 10−500μg/L. The recoveries ofβ-ionone in ultrapure water and tap water samples were 88%−95% and 110%−114%, respectively. The relative standard deviations (RSD) were less than 10%. The method detection limit (MDL) and rejection quality level (RQL) were achieved at 1.98μg/L and 6.53μg/L, respectively. LLE-GC-MS was demonstrated to be a rapid and convenient method for the determination ofβ-ionone in water samples.

  3. 气相色谱-质谱联用分析倍花中化学成分%Compounds Analysis in Beihua by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    欧阳玉祝; 张辞海; 魏燕; 吴道宏

    2013-01-01

    Volatile oils and extracts were prepared from beihua.Compounds in volatile oil and fatty acids in extrats were analyzed by gas chromatography-mass spectrometry.The results showed that fifty compounds were detected from volatile oil with 17.94% of ethyl isopropyl ether,4.4% of hexanoic acid,3.43% of N,N-dimethylaniline,3.72% of dodecanoic acid,14.89% of tetradecanoic acid,8.88% of palmitic acid and 23.8% of cis,cis,cis-7,10,13-hexadecatrienal being the main components.Eighteen compounds were detected from extracts of methyl-esterification,and ten of them are fatty acids.The content of unsaturated fatty acids is 19.2% with linolenic acid being 16.13%,and that of saturated fatty acids is 51.7% with tetradecanoic acid and palmitic acid of 26.88% and 17.03%,respectively.%以植物倍花为原料制备倍花挥发油和倍花提取液,用气相色谱-质谱联用技术分析了挥发油的化学成分和提取液的脂肪酸组成与含量.实验结果表明,挥发油中共检出五十个组分,主要成分是乙基异丙醚、己酸、N,N-二甲基苯胺、月桂酸、肉豆蔻酸、棕榈酸、7(Z),10(Z),13 (Z)-十六碳三烯酮,其相对含量分别为17.94%、4.48%、3.43%、3.72%、14.89%、8.88%、23.8%.倍花提取液经甲酯化后共检出十八种物质,其中有十种脂肪酸,不饱和脂肪酸与饱和脂肪酸总含量分别为19.2%和51.7%;不饱和脂肪酸中亚麻酸含量达16.13%,饱和脂肪酸主要是肉豆蔻酸和棕榈酸,含量分别为26.88%和17.03%.

  4. Application of Gas Chromatography-Mass Spectrometry Method in Food Safety Analysis%气相色谱-质谱联用法在食品安全分析中的应用

    Institute of Scientific and Technical Information of China (English)

    王建玲; 候学会; 王国庆

    2013-01-01

    This paper had summarized the application of Gas Chromatography-Mass Spectrometry (GC-MS) methodology on food safety analysis field, such as analysis of food additive, pesticide residues, animal medicine residues, contamination and so on. Meanwhile, we predicted the broad application prospect of the GC-MS process.%  综述近年来气相色谱一质谱联用技术在食品安全分析中的应用,这些应用包括对食品中添加剂、农药残留、兽药残留和污染物质等的分析,并对该方法的应用前景进行了展望。

  5. 气相色谱-质谱联用法在食品安全分析中的应用%Application of Gas Chromatography-Mass Spectrometry Method in Food Safety Analysis

    Institute of Scientific and Technical Information of China (English)

    王建玲; 候学会; 王国庆

    2013-01-01

      综述近年来气相色谱一质谱联用技术在食品安全分析中的应用,这些应用包括对食品中添加剂、农药残留、兽药残留和污染物质等的分析,并对该方法的应用前景进行了展望。%This paper had summarized the application of Gas Chromatography-Mass Spectrometry (GC-MS) methodology on food safety analysis field, such as analysis of food additive, pesticide residues, animal medicine residues, contamination and so on. Meanwhile, we predicted the broad application prospect of the GC-MS process.

  6. Chlorinated hydrocarbons in the atmosphere - Analysis at the parts-per-trillion level by GC-MS. [Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Tyson, B. J.

    1975-01-01

    The propellant gases (Freons) used in aerosol spray cans can diffuse into the earth's upper atmosphere where they can react with the unfiltered ultraviolet radiation from the sun to reduce the earth's protective ozone layer. These Freons have been identified commonly by gas chromatography. Mass spectrometer data confirm other reports on the widespread concentrations of the Freons in the troposphere and demonstrate the presence of Freon 113 which has not been previously identified.

  7. Improved method for the determination of hydroxymethylfurfural in baby foods using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Gökmen, Vural; Senyuva, Hamide Z

    2006-04-19

    An improved analytical method for the rapid, reliable, and sensitive determination of hydroxymethylfurfural (HMF) in baby foods is described. It entailed aqueous extraction from food matrix with simultaneous clarification using Carrez I and II reagents, solid-phase extraction cleanup using Oasis HLB, and analysis by liquid chromatography-mass spectrometry. A narrow-bore column allowed fast chromatographic separation with good resolution of HMF and matrix coextractives. In positive atmospheric pressure chemical ionization conditions, precursor and compound-specific ions were sensitively detected in selected ion monitoring mode. Sample preparation with efficient cleanup followed by fast chromatographic analysis allowed the analysis to be completed in <20 min. Recovery ranged between 91.8 and 94.7% for spiking levels of 0.25, 1.0, and 5.0 mg/kg HMF in cereal-based baby foods. The method was shown to be successful when using liquid chromatography coupled to ultraviolet detection at 285 nm. PMID:16608199

  8. Analysis of the Nitrogen Isotope Compositions in Natural Gases by Gas Chromatography-Mass Spectrometry%天然气中氮同位素组成的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    李立武; 杜丽

    2004-01-01

    A test about nitrogen isotopic compositions in natural gases is preformed by a gas chromatography-mass spectrometry (GC/MS). GC can easily separate N2 and CO.The experimental standard deviation of nitrogen isotopic compositions is less than 1‰.The nitrogen isotopic compositions with N2 content of 0. 1% may be measured in this way.

  9. Pilot Study on Pyrolysis Analysis of Decabromodiphenyl Ether by Gas Chromatography-Mass Spectrometry%十溴二苯醚的裂解气相色谱-质谱初步研究

    Institute of Scientific and Technical Information of China (English)

    吴惠勤; 黄晓兰; 黄芳; 林晓珊; 李逸; 邓欣

    2004-01-01

    The pyrolysis products of decabromodiphenyl ether (DBDE)were researched using pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) and the thermal pyrolysis mechanism was discussed. The results showed the main pyrolysis products of decabromodiphenyl ether are boromoform, bromobenzene, tetrabromoethene, tetrabromobutadiene and tetrabromobenzene.

  10. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    Science.gov (United States)

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-01

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  11. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    Science.gov (United States)

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  12. Enhancement of the capabilities of liquid chromatography-mass spectrometry with derivatization: general principles and applications.

    Science.gov (United States)

    Xu, Fengguo; Zou, Li; Liu, Ying; Zhang, Zunjian; Ong, Choon Nam

    2011-01-01

    The integration of liquid chromatography-mass spectrometry (LC-MS) with derivatization is a relatively new and unique strategy that could add value and could enhance the capabilities of LC-MS-based technologies. The derivatization process could be carried out in various analytical steps, for example, sampling, storage, sample preparation, HPLC separation, and MS detection. This review presents an overview of derivatization-based LC-MS strategy over the past 10 years and covers both the general principles and applications in the fields of pharmaceutical and biomedical analysis, biomarker and metabolomic research, environmental analysis, and food-safety evaluation. The underlying mechanisms and theories for derivative reagent selection are summarized and highlighted to guide future studies.

  13. Characterization of volatile organic compounds by thermal desorption/gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Carbonaceous triple sorbent traps (TSTs) have been widely used to collect and concentrate volatile organic compounds (VOCs) in vapor phase samples for subsequent GC/MS analysis. Recently, this laboratory has been involved in sampling and analyzing VOCs collected from various emission sources, including headspace samples from underground storage tanks at the Department of Energy's Hanford site, in Richland, Washington. In order to evaluate the sampling adequacy and to assess any health-related impact based on the analysis results, a validated method must be employed. Therefore, the main objective of this study was to develop a methology for thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) determination of VOCs in the vapor phase samples collected on Carbotrap C/Carbotrap/Carbosieve S III triple sorbent traps. Techniques used in method validation included VOC standard generation, thermal desorption efficiency, reproducibility of spiking on and recovery from TST, use of internal standards, detection limits determination, linearity and reproducibility of calibration

  14. Determination of constituents of essential oil from Angelica sinensis by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU Ming-jian; SUN Xian-jun; DAI Yuan-hui; GUO Fang-qiu; HUANG Lan-fang; LIANG Yi-zeng

    2005-01-01

    Gas chromatography-mass spectrometry (GC-MS) coupled with chemometric resolution upon two-dimensional data was employed to analyze the constituents of essential oils of Angelica sinensis. Constituents in essential oils of Angelica sinensis root were identified by GC-MS with the help of subwindow factor analysis (SFA) method resolving two-dimensional original data into mass spectra and chromatograms. 76 of 97 separated constituents in essential oil of Angelica sinensis root were identified and quantified, and they account for about 91.36% of the total content. The results show that ligustilide, butylene phthalide, 2-methoxy-4-vinylphenol, carvacrol, allo-ocimene,2,6,6-trimethylbicyclo-[3,1,1]hept-2-ene are the main constituents in essential oil of Angelica sinensis root.

  15. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  16. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  17. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  18. Datura stramonium poisoning. Identification of tropane alkaloids in urine by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Nogué, S; Pujol, L; Sanz, P; de la Torre, R

    1995-01-01

    A case of acute poisoning by ingestion of Datura stramonium infusion is reported. The patient presented with a typical anticholinergic syndrome (dryness of mouth, mydriasis, flushing, tachycardia, agitation, hallucinations) and was treated with symptomatic and supportive measures. The presence of tropane belladona alkaloids in a urine sample was demonstrated by gas chromatography-mass spectrometry. PMID:7601297

  19. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2012-01-01

    Full Text Available The combination of liquid chromatography (LC with mass spectrometry (MS in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others since the same ones are continuously being released in the environment mainly as a result of the manufacturing processes, the disposal of unused or expired products, and the excreta. Because these micropollutants are not completely removed in the environment, very specific and sensitive analytical procedures are needed for their identification and quantification. High performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (or LC-MS2 and especially time-of-flight mass spectrometry (TOF/MS, has allowed that many environmental contaminants that are highly polar or nonvolatile or have a high molecular weight to be analyzed or identified. In this work we present an overview focused on the developments of liquid chromatography mass spectrometry applied to the analysis of the main classes of micropollutants in aqueous and solid environmental samples. Various aspects of methodologies based on these techniques, including sample preparation (extraction/preconcentration and matrix effects, are discussed.

  20. Analysis of wine volatile profile by purge-and-trap-gas chromatography-mass spectrometry. Application to the analysis of red and white wines from different Spanish regions.

    Science.gov (United States)

    Aznar, Margarita; Arroyo, Teresa

    2007-09-21

    The purge-and-trap extraction method, coupled to a gas chromatograph with mass spectrometry detection, has been applied to the determination of 26 aromatic volatiles in wine. The method was optimized, validated and applied to the analyses of 40 red and white wines from 7 different Spanish regions. Principal components analyses of data showed the correlation between wines of similar origin.

  1. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  2. Development and validation of confirmatory method for analysis of nitrofuran metabolites in milk, honey, poultry meat and fish by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fatih Alkan

    2016-03-01

    Full Text Available In this study we have devoloped and validated a confirmatory analysis method for nitrofuran metabolites, which is in accordance with European Commission Decision 2002/657/EC requirements. Nitrofuran metabolites in honey, milk, poultry meat and fish samples were acidic hydrolised followed by derivatisation with nitrobenzaldehyde and liquid-liquid extracted with ethylacetate. The quantitative and confirmative determination of nitrofuran metbolites was performed by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS in the positive ion mode. In-house method validation was performed and reported data of validation (specificity, linearity, recovery, CCα and CCβ. The advantage of this method is that it avoids the use of clean-up by Solid-Phase Extraction (SPE. Furthermore, low levels of nitrofuran metabolites are detectable and quantitatively confirmed at a rapid rate in all samples.

  3. Analysis of volatile components in mosquito.repellent sticks by headspace-gas chromatography/mass spectrometry%顶空气相色谱质谱法分析避蚊贴中挥发性成分

    Institute of Scientific and Technical Information of China (English)

    徐昕荣; 区雪连; 马瑜璐; 朱斌

    2011-01-01

    采用顶空-气相色谱-质谱联用技术分析鉴定了4种避蚊贴中的挥发性物质.样品经90℃、45 min顶空后,采用GC-MS进行定性分析.用面积归一化法得出各组分的相对含量.结果表明:经NIST质谱数据库检索和文献对照,样品Ⅰ、Ⅱ、Ⅲ和Ⅳ分别检出并确定了33、39、39和24种成分.样品Ⅰ、Ⅱ、Ⅲ和Ⅳ主要成分分别为桉树醇(相对含量39.61%)、蒎烷(相对含量32.61%)、柠檬烯(相对含量34.40%)和为香茅醛(相对含量41.31%),其他成分主要为烯、醇、酮、醚等.%The volatile components of four mosquito-repellent sticks were analyzed by headspace-gas chromatography/mass spectrometry(HS-GC/MS). Samples were extracted at 90℃ for 45 min by headspace and separated by VOC capillary column, then were determined by gas chromatography-mass spectrometry. After normalization of peak areas, the relative contents of the identified compounds were obtained. The results showed that the samples Ⅰ、Ⅱ、Ⅲ and Ⅳ were detected and the components 33、39、39 and 24 were identified by comparing their mass spectra with those contained in the NIST mass spectrometry library and in some references literatures. The largest quantities of compounds of the samples Ⅰ、Ⅱ、Ⅲ and Ⅳ were eucalyptol ( relative content of 39.61% ) 、pinane ( relative content of 32.61% ) 、 limonene ( relative content of 34.40% ) and citronellal (relative content of 41.31%), respectively. In addition, other components were mainly alkene 、alcohol 、ketones and ether. The method is simple, rapid, accurate and suitable for the analysis of volatile flavor components in mosquito-repellent sticks.

  4. Characterization and classification of pequi trees (Caryocar brasiliense Camb.) based on the profile of volatile constituents using headspace solid-phase microextraction - gas chromatography - mass spectrometry and multivariate analysis

    OpenAIRE

    Renata França Cassimiro Belo; Rodinei Augusti; Paulo Sérgio Nascimento Lopes; Roberto Gonçalves Junqueira

    2013-01-01

    In order to determine the variability of pequi tree (Caryocar brasiliense Camb.) populations, volatile compounds from fruits of eighteen trees representing five populations were extracted by headspace solid-phase microextraction and analyzed by gas chromatography-mass spectrometry. Seventy-seven compounds were identified, including esters, hydrocarbons, terpenoids, ketones, lactones, and alcohols. Several compounds had not been previously reported in the pequi fruit. The amount of total volat...

  5. β-sitosterol in different parts of Saraca asoca and herbal drug ashokarista: Quali-quantitative analysis by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Anjum Gahlaut

    2013-01-01

    Full Text Available β-sitosterol is an important component in food and herbal products and beneficial in hyperlipidemia. Its higher concentrations in serum may lead to coronary artery disease in case of sitosterolemia. Therefore, it is essential to determine the quantity of β-sitosterol in food and herbal drugs. Saraca asoca and its preparations have been widely used by traditional healers are also a source of β-sitosterol. In the present study, quantitative estimation of β-sitosterol present in hot and cold water extracts of bark, regenerated bark, leaves and flowers of the S. asoca and Ashokarista drugs were carried out first time using high performance liquid chromatography coupled (HPLC with quadrupole time-of-flight mass spectrometry. Different concentrations of β-sitosterol and crude extracts were estimated by HPLC and targeted mass spectrometry. Standard curve for β-sitosterol was prepared from the intensities of transitions (397.50 → 147.0987 m/z having regression coefficient (r 2 0.9952. Out of eight extracts and two drugs used in the study bark water, leaves water and leaves hot water extracts were found to have a considerable quantity of β-sitosterol, i.e. 170, 123.5 and 19.3 ng/mL, respectively. The results showed significant differences in the distribution of β-sitosterol among different organs of S. asoca and drugs prepared from its bark. HPLC/electrospray ionizationmass spectroscopy method is accurate, reproducible and requires less specimen, sample preparation and analysis time over HPLC assay. This type of approaches could be helpful for the quality control of herbal medicines and provides necessary information for the rational utilization of plant resources.

  6. Recent progress in polar metabolite quantification in plants using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Zhiqian Liu; Simone Rochfort

    2014-01-01

    Metabolite analysis or metabolomics is an impor-tant component of systems biology in the post-genomic era. Although separate liquid chromatography (LC) methods for quantification of the major classes of polar metabolites of plants have been available for decades, a single method that enables simultaneous determination of hundreds of polar metabolites is possible only with gas chromatography-mass spectrometry (GC-MS) techniques. The rapid expansion of new LC stationary phases in the market and the ready access of mass spectrometry in many laboratories provides an excellent opportunity for developing LC-MS based methods for multi-target quantification of polar metabolites. Although various LC-MS methods have been developed over the last 10 years with the aim to quantify one or more classes of polar compounds in different matrices, currently there is no consensus LC-MS method that is widely used in plant metabolomics studies. The most promising methods applicable to plant metabolite analysis wil be reviewed in this paper and the major problems encountered highlighted. The aim of this review is to provide plant scientists, with limited to moderate experience in analytical chemistry, with up-to-date and simplified information regarding the current status of polar metabolite analysis using LC-MS techniques.

  7. Pentafluorobenzyl esterification of haloacetic acids in tap water for simple and sensitive analysis by gas chromatography/mass spectrometry with negative chemical ionization.

    Science.gov (United States)

    Zhao, Can; Fujii, Yukiko; Yan, Junxia; Harada, Kouji H; Koizumi, Akio

    2015-01-01

    Chlorine is the most widely used disinfectant for control of waterborne diseases in drinking water treatment. It can react with natural organic matter in water and form haloacetic acids (HAAs). For analysis of HAA levels, derivatization with diazomethane is commonly recommended as the standard methodology in Japan. However, diazomethane is a carcinogenic alkylating agent. Therefore, in this study, a safe, simple, and sensitive quantification method was developed to monitor HAAs in drinking water. Pentafluorobenzyl esterification was used for pretreatment. The pentafluorobenzyl-ester derivative was detected by gas chromatography-negative ion chemical ionization-mass spectrometry analysis with very high sensitivity for HAAs analysis. The method has low detection limits (8-94 ng L(-1)) and good recovery rates (89-99%) for HAAs. The method was applied to 30 tap water samples from 15 cities in the Kansai region of Japan. The levels of HAAs detected were in the range 0.54-7.83 μg L(-1). Dichloroacetic acid, trichloroacetic acid, and bromochloroacetic acid were the major HAAs detected in most of the tap water, and accounted for 29%, 20% and 19% of the total HAAs, respectively. This method could be used for routine monitoring of HAAs in drinking water without exposure of workers to occupational hazards.

  8. Analytical Variables Affecting Analysis of F2-Isoprostanes and F4-Neuroprostanes in Human Cerebrospinal Fluid by Gas Chromatography/Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hsiu-Chuan Yen

    2013-01-01

    Full Text Available F2-isoprostanes (F2-IsoPs are a gold marker of lipid peroxidation in vivo, whereas F4-neuroprostanes (F4-NPs measured in cerebrospinal fluid (CSF or brain tissue selectively indicate neuronal oxidative damage. Gas chromatography/negative-ion chemical-ionization mass spectrometry (GC/NICI-MS is the most sensitive and robust method for quantifying these compounds, which is essential for CSF samples because abundance of these compounds in CSF is very low. The present study revealed potential interferences on the analysis of F2-IsoPs and F4-NPs in CSF by GC/NICI-MS due to the use of improper analytical methods that have been employed in the literature. First, simultaneous quantification of F2-IsoPs and F4-NPs in CSF samples processed for F4-NPs analysis could cause poor chromatographic separation and falsely higher F2-IsoPs values for CSF samples with high levels of F2-IsoPs and F4-NPs. Second, retention of unknown substances in GC columns from CSF samples during F4-NPs analysis and from plasma samples during F2-IsoPs analysis might interfere with F4-NPs analysis of subsequent runs, which could be solved by holding columns at a high temperature for a period of time after data acquisition. Therefore, these special issues should be taken into consideration when performing analysis of F2-IsoPs and F4-NPs in CSF to avoid misleading results.

  9. Analysis of aspartyl peptide degradation products by high-performance liquid chromatography and high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    De Boni, Silvia; Oberthür, Christine; Hamburger, Matthias; Scriba, Gerhard K E

    2004-01-01

    A reversed-phase HPLC method for the analysis of degradation products of the model aspartyl tripeptides Phe-Asp-GlyNH2 and Gly-Asp-PheNH2 after incubation at pH 2 and 10 was developed. Most of the compounds could be separated with a gradient of acetonitrile in water containing 0.1% trifluoroacetic acid. Resolution of the isomeric pairs L-Phe-alpha-L-Asp-GlyNH2/L-Phe-beta-L-Asp-GlyNH2 and L-Phe-alpha-D-Asp-GlyOH/L-Phe-beta-D-Asp-GlyOH was achieved with a gradient of acetonitrile in phosphate buffer, pH 5.0. Under acidic conditions the major degradation pathway was cleavage of the peptide backbone amide bonds yielding dipeptides and amino acids, C-terminal deamidation as well as formation of succidinimyl peptides. At alkaline pH both deamidation of the C-terminal amide as well as isomerization and concomitant enantiomerization of Asp were observed. The peaks were identified both by reference substances and by online electrospray mass spectrometry. The results were compared to a previous developed capillary electrophoresis method. Diastereomeric pairs ofpeptides that could not be separated by capillary electrophoresis were resolved by HPLC while the separation of corresponding pairs of alpha- and beta-Asp peptides was not always achieved by HPLC in contrast to capillary electrophoresis illustrating that both techniques can be complimentary in peptide analysis. PMID:14753775

  10. Application of pyrolysis-gas chromatography-mass spectrometry and multivariate analysis to study bacteria and fungi in biofilms used for bioremediation.

    Science.gov (United States)

    Melucci, Dora; Fedi, Stefano; Locatelli, Marcello; Locatelli, Clinio; Montalbani, Simona; Cappelletti, Martina

    2013-08-01

    Biofilms are communities of microorganisms adhering to a surface and embedded in an extracellular polymeric matrix, frequently associated with disease and contamination, and also used for engineering applications such as bioremediation. A mixed biofilm formed by bacteria and fungi may provide an optimal habitat for addressing contaminated areas. To exploit the potential of natural microbial communities consisting of bacteria and fungi, it is essential to understand and control their formation. In this work, a method to discriminate among bacteria of genera Bacillus, Pseudomonas, Rhodococcus with respect to the fungus Pleorotus in a biofilm by means of pyrolysis-gaschromatography-mass spectrometry and multivariate analysis is reported. Methylated fatty acids were chosen as biomarkers of microorganisms in the pyrolysates. In situ thermal hydrolysis and methylation was applied. Pyrograms were used as fingerprints, thus allowing for the characterization of whole cells analyzed without any sample pretreatment. Normalized pyrographic peak areas were chosen as variables for chemometric data processing. Principal components analysis was applied as a data exploration tool. Satisfactory results were obtained in analyzing a real biofilm. The influence of growth medium on whole bacteria fatty acid cell composition was also explored.

  11. Biomedical applications of gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Gas chromatography coupled with mass-spectrometry (GC/MS) is a modern technique, which has very important applications in the biomedical area. A large number of qualitative and quantitative determinations of drugs, amino acids, vitamins, lipids, aroma compounds, important nutrients, herb extracts were developed. The extraction procedure is the first important step in the analytical work. The internal standard is usually added at the very begin ing of the quantitative work. The best one is the stable isotopic labeled compound, usually the analogue of the compound of interest. Stable isotopic internal standard or compounds from the same chemical class having boiling point close to that of the compound of interest were used. Quantitation needs very well selected standards and method validation. Some validated methods for the determination of drugs and some active principles in biological media are presented. Several preconcentration extraction procedures were used. The quantitative determinations by detection (GC-MS) were performed. Good validation parameters were obtained: precision, accuracy, linearity in the range of interest, good limit of detection and quantitation, selectivity and specificity. Chromatography was performed on a 5% phenyl methyl polysiloxane column (15 or 30 m x 0.25 mm I.D., 0.25 μm film thickness) operated in suitable temperature programs. Helium carrier gas flow was 1ml/min. Ionization was performed by electron impact and detection in scan or selected ion monitoring (SIM) modes. The methods provided high response linearity (mean r = 0.99), precision and accuracy (< 10% C.V.). Applications of the quantitative methods in biomedical area are described. (author)

  12. Nephron Toxicity Profiling via Untargeted Metabolome Analysis Employing a High Performance Liquid Chromatography-Mass Spectrometry-based Experimental and Computational Pipeline.

    Science.gov (United States)

    Ranninger, Christina; Rurik, Marc; Limonciel, Alice; Ruzek, Silke; Reischl, Roland; Wilmes, Anja; Jennings, Paul; Hewitt, Philip; Dekant, Wolfgang; Kohlbacher, Oliver; Huber, Christian G

    2015-07-31

    Untargeted metabolomics has the potential to improve the predictivity of in vitro toxicity models and therefore may aid the replacement of expensive and laborious animal models. Here we describe a long term repeat dose nephrotoxicity study conducted on the human renal proximal tubular epithelial cell line, RPTEC/TERT1, treated with 10 and 35 μmol·liter(-1) of chloroacetaldehyde, a metabolite of the anti-cancer drug ifosfamide. Our study outlines the establishment of an automated and easy to use untargeted metabolomics workflow for HPLC-high resolution mass spectrometry data. Automated data analysis workflows based on open source software (OpenMS, KNIME) enabled a comprehensive and reproducible analysis of the complex and voluminous metabolomics data produced by the profiling approach. Time- and concentration-dependent responses were clearly evident in the metabolomic profiles. To obtain a more comprehensive picture of the mode of action, transcriptomics and proteomics data were also integrated. For toxicity profiling of chloroacetaldehyde, 428 and 317 metabolite features were detectable in positive and negative modes, respectively, after stringent removal of chemical noise and unstable signals. Changes upon treatment were explored using principal component analysis, and statistically significant differences were identified using linear models for microarray assays. The analysis revealed toxic effects only for the treatment with 35 μmol·liter(-1) for 3 and 14 days. The most regulated metabolites were glutathione and metabolites related to the oxidative stress response of the cells. These findings are corroborated by proteomics and transcriptomics data, which show, among other things, an activation of the Nrf2 and ATF4 pathways. PMID:26055719

  13. Analysis of Volatile Components in Semen Sojae Praepatum with Automatic Static Headspace and Gas Chromatography-Mass Spectrometry%静态顶空-气质联用分析淡豆豉中挥发性成分

    Institute of Scientific and Technical Information of China (English)

    柴川; 于生; 崔小兵; 张爱华; 朱栋; 单晨啸; 文红梅

    2013-01-01

    It was the first report on the volatile components contained in Semen Sojae Praepatum. For the analysis, the Semen Sojae Praepatum was analyzed by automatic static headspace and gas Chromatography-mass Spectrometry. A total of 27 compounds were identified in Semen Sojae Praepatum through the computer retrieval on the NIST5 mass spectral library. They consisted of 11 generality components, such as 2-Butanone, Butanal 3-methyl-, Butanal 2-methyl-, Limonene and 16 special components, such as copaene, Pyrazine, tetramethyl-, 2,3,5-Trimethyl-6-ethylpyrazine, Bicyclo[2.2.1]heptan-2-ol,1,7,7-trimethyl-,acetate,(1S-endo)-. Meanwhile, the quantitative analysis was taken using area normalization method, which showed that some difference was detected among six batches of Semen Sojae Praepatum. The results indicated that automatic static headspace and gas chromatography-mass spectrometry was a fast,easy,efficient and accurate method to analyze the volatile components in Semen Sojae Praepatum , and we thought that the findings may promote the fingerprint research of the volatile components in Semen Sojae Praepatum , to provide a scientific basis for the establishment of the quality standard.%  采用自动化静态顶空(HS)-气质联用(GC-MS)技术对6个批次淡豆豉的挥发性成分进行快速分析鉴定。从测定到的40多种成分中确定了2-丁酮、3-甲基丁醛、2-甲基丁醛、香芹烯等11种共有化合物及2,3,5-三甲基吡嗪、L-乙酸冰片酯、古巴烯、四甲基吡嗪等16种非共有化合物;同时使用峰面积归一化法计算了27种挥发性成分的相对含量,各组分的质量分数存在一定差异。研究表明,使用自动化静态顶空气质联用法测定淡豆豉的挥发性成分快速简便,且在一定程度上促进了淡豆豉挥发性成分的指纹图谱构建,为淡豆豉质量标准的建立提供了参考。

  14. Proteomic analysis of prolactinoma cells by immuno-laser capture microdissection combined with online two-dimensional nano-scale liquid chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chen Luping

    2010-01-01

    Full Text Available Abstract Background Pituitary adenomas, the third most common intracranial tumor, comprise nearly 16.7% of intracranial neoplasm and 25%-44% of pituitary adenomas are prolactinomas. Prolactinoma represents a complex heterogeneous mixture of cells including prolactin (PRL, endothelial cells, fibroblasts, and other stromal cells, making it difficult to dissect the molecular and cellular mechanisms of prolactin cells in pituitary tumorigenesis through high-throughout-omics analysis. Our newly developed immuno-laser capture microdissection (LCM method would permit rapid and reliable procurement of prolactin cells from this heterogeneous tissue. Thus, prolactin cell specific molecular events involved in pituitary tumorigenesis and cell signaling can be approached by proteomic analysis. Results Proteins from immuno-LCM captured prolactin cells were digested; resulting peptides were separated by two dimensional-nanoscale liquid chromatography (2D-nanoLC/MS and characterized by tandem mass spectrometry. All MS/MS spectrums were analyzed by SEQUEST against the human International Protein Index database and a specific prolactinoma proteome consisting of 2243 proteins was identified. This collection of identified proteins by far represents the largest and the most comprehensive database of proteome for prolactinoma. Category analysis of the proteome revealed a widely unbiased access to various proteins with diverse functional characteristics. Conclusions This manuscript described a more comprehensive proteomic profile of prolactinomas compared to other previous published reports. Thanks to the application of immuno-LCM combined with online two-dimensional nano-scale liquid chromatography here permitted identification of more proteins and, to our best knowledge, generated the largest prolactinoma proteome. This enlarged proteome would contribute significantly to further understanding of prolactinoma tumorigenesis which is crucial to the management of

  15. 司法案例中芬那露的气相色谱-质谱分析%Analysis of Chlormethazanone by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    张莉英; 张春水; 郑珲

    2004-01-01

    Chlormethazanone was a medicine used for calming, A method the determination of chlormethazanone in human stomach and liver tissue by gas chromatographic-mass spectrometry was developed. This method had been successfully applied into judicial identification.

  16. Tandem Extraction/Liquid Chromatography-Mass Spectrometry Protocol for the Analysis of Acrylamide and Surfactant-related Compounds in Complex Aqueous Environmental Samples

    Science.gov (United States)

    The development of a liquid chromatography‐mass spectrometry (LC‐MS)‐based strategy for the detection and quantitation of acrylamide and surfactant‐related compounds in aqueous complex environmental samples.

  17. NEW RAPID ANALYSIS OF TWO CLASSES OF PESTICIDES IN FOOD WASTEWATER BY QuEChERS-LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Bożena Lozowicka

    2016-07-01

    Full Text Available The rapid analytical method was developed in response to increasing concern over the environmental impact of azoles (sterol biosynthesis inhibitors and neonicotinoids (nicotinic acetylcholine receptor site. These chemicals are commonly used to protect fruit and vegetables crops against fungi and pests. Seven insecticides and twenty one fungicides commonly occurring in food industrial wastewater have been determined. For this purpose, active substances from two new pesticide classes were extracted and isolated by QuEChERS by addition of acetonitrile, buffering salts and chitin as a clean-up sorbent. The novelty of this procedure was one step sample preparation including extraction and removing of co-extracts in short time. Instrumental analysis was conducted by liquid chromatography coupled with mass spectrometry using multiple reaction monitoring. The limits of detection ranged from 0.05 to 0.2 µg/L with satisfactory sensitivity (limits of detection below 30 ng/L, accuracy and precision. The recoveries for the pesticides ranged from 81-103%, with high repeatability (n = 3, RSD ≤ 9% and low LOQs (0.6-0.9 ng/L. Matrix effects calculated were less than 12% for all analyses. The method was applied to routine analysis of food industrial wastewater. Concerning the results, total pesticide levels in most cases were below 1 μg/L. The most significant pesticides in terms of concentration and frequency of detection were acetamiprid (0.07 μg L-1; tebuconazole (1.2 μg L-1 and thiacloprid (0.04 μg L-1.

  18. Analysis and quantitation of volatile organic compounds emitted from plastics used in museum construction by evolved gas analysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Samide, Michael J; Smith, Gregory D

    2015-12-24

    Construction materials used in museums for the display, storage, and transportation of artwork must be assessed for their tendency to emit harmful pollution that could potentially damage cultural treasures. Traditionally, a subjective metals corrosion test known as the Oddy test has been widely utilized in museums for this purpose. To augment the Oddy test, an instrumental sampling approach based on evolved gas analysis (EGA) coupled to gas chromatography (GC) with mass spectral (MS) detection has been implemented for the first time to qualitatively identify off-gassed pollutants under specific conditions. This approach is compared to other instrumental methods reported in the literature. This novel application of the EGA sampling technique yields several benefits over traditional testing, including rapidity, high sensitivity, and broad detectability of volatile organic compounds (VOCs). Furthermore, unlike other reported instrumental approaches, the EGA method was used to determine quantitatively the amount of VOCs emitted by acetate resins and polyurethane foams under specific conditions using both an external calibration method as well as surrogate response factors. EGA was successfully employed to rapidly characterize emissions from 12 types of common plastics. This analysis is advocated as a rapid pre-screening method to rule out poorly performing materials prior to investing time and energy in Oddy testing. The approach is also useful for rapid, routine testing of construction materials previously vetted by traditional testing, but which may experience detrimental formulation changes over time. As an example, a case study on batch re-orders of rigid expanded poly(vinyl chloride) board stock is presented.

  19. Analysis and quantitation of volatile organic compounds emitted from plastics used in museum construction by evolved gas analysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Samide, Michael J; Smith, Gregory D

    2015-12-24

    Construction materials used in museums for the display, storage, and transportation of artwork must be assessed for their tendency to emit harmful pollution that could potentially damage cultural treasures. Traditionally, a subjective metals corrosion test known as the Oddy test has been widely utilized in museums for this purpose. To augment the Oddy test, an instrumental sampling approach based on evolved gas analysis (EGA) coupled to gas chromatography (GC) with mass spectral (MS) detection has been implemented for the first time to qualitatively identify off-gassed pollutants under specific conditions. This approach is compared to other instrumental methods reported in the literature. This novel application of the EGA sampling technique yields several benefits over traditional testing, including rapidity, high sensitivity, and broad detectability of volatile organic compounds (VOCs). Furthermore, unlike other reported instrumental approaches, the EGA method was used to determine quantitatively the amount of VOCs emitted by acetate resins and polyurethane foams under specific conditions using both an external calibration method as well as surrogate response factors. EGA was successfully employed to rapidly characterize emissions from 12 types of common plastics. This analysis is advocated as a rapid pre-screening method to rule out poorly performing materials prior to investing time and energy in Oddy testing. The approach is also useful for rapid, routine testing of construction materials previously vetted by traditional testing, but which may experience detrimental formulation changes over time. As an example, a case study on batch re-orders of rigid expanded poly(vinyl chloride) board stock is presented. PMID:26687162

  20. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group : determination of triazine and phenylurea herbicides and their degradation products in water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, Edward Alan; Strahan, Alex P.; Thurman, Earl Michael

    2002-01-01

    An analytical method for the determination of 7 triazine and phenylurea herbicides and 12 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is presented in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using 0.5 gram graphitized carbon as the solid-phase extraction media followed by liquid chromatography/mass spectrometry. Three different water-sample matrices?ground-water, surface-water, and reagent-water samples?spiked at 0.2 and 2.0 micrograms per liter were analyzed. Method detection limits ranged from 0.013 to 0.168 microgram per liter for the parent triazine herbicides and the triazine degradation products. Method detection limits ranged from 0.042 to 0.141 microgram per liter for the parent phenylurea herbicides and their degradation products. Mean recoveries for the triazine compounds in the ground- and surface-water samples generally ranged from 72.6 to 117.5 percent, but deethyl-cyanazine amide was recovered at 140.5 percent. Mean recoveries from the ground- and surface-water samples for the phenylurea compounds spiked at the 2.0-micrograms-per-liter level ranged from 82.1 to 114.4 percent. The mean recoveries for the phenylureas spiked at 0.2-microgram per liter were less consistent, ranging from 87.0 to 136.0 percent. Mean recoveries from reagent-water samples ranged from 87.0 to 109.5 percent for all compounds. The triazine compounds and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter, with the exception of deethylcyanazine and deethylcyanazine amide which are reported at 0.20 to 2.0 micrograms per liter. The phenylurea compounds and their degradation products are reported in concentrations ranging from 0.20 to 2.0 micrograms per liter. The upper concentration limit was 2

  1. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group?Determination of acetamide herbicides and their degradation products in water using online solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, E.A.; Strahan, A.P.

    2003-01-01

    An analytical method for the determination of 6 acetamide herbicides (acetochlor, alachlor, dimethenamid, flufenacet, metolachlor, and propachlor) and 16 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is described in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using octadecylsilane as the solid-phase extraction media on online automated equipment followed by liquid chromatography/mass spectrometry. The method uses only 10 milliliters of sample per injection. Three different water-sample matrices, a reagent-water, a ground-water, and a surface-water sample spiked at 0.10 and 1.0 microgram per liter, were analyzed to determine method performance. Method detection limits ranged from 0.004 to 0.051 microgram per liter for the parent acetamide herbicides and their degradation products. Mean recoveries for the acetamide compounds in the ground- and surface-water samples ranged from 62.3 to 117.4 percent. The secondary amide of acetochlor/metolachlor ethanesulfonic acid (ESA) was recovered at an average rate of 43.5 percent. The mean recoveries for propachlor and propachlor oxanilic acid (OXA) were next lowest, ranging from 62.3 to 95.5 percent. Mean recoveries from reagent-water samples ranged from 90.3 to 118.3 percent for all compounds. Overall the mean of the mean recoveries of all compounds in the three matrices spiked at 0.10 and 1.0 microgram per liter ranged from 89.9 to 100.7 percent, including the secondary amide of acetochlor/metolachlor ESA and the propachlor compounds. The acetamide herbicides and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter. The upper concentration limit is 2.0 micrograms per liter for all compounds without dilution. With the exception of the secondary amide of

  2. A liquid chromatography-mass spectrometry approach to study "glucosinoloma" in broccoli sprouts.

    Science.gov (United States)

    Maldini, Mariateresa; Baima, Simona; Morelli, Giorgio; Scaccini, Cristina; Natella, Fausta

    2012-09-01

    Glucosinolates are an important class of secondary plant metabolites, possessing health-promoting properties. Young broccoli plants are a very good source of glucosinolates with concentrations several times greater than in mature plants. The aim of our study was to develop a liquid chromatography-mass spectrometry and liquid chromatography/tandem mass spectrometry qualitative and quantitative method for the measure of glucosinolates in broccoli sprouts. The described method provides high sensitivity and specificity, allowing a rapid and simultaneous determination of 14 glucosinolates. The proposed method has been validated for eight glucosinolates: glucobrassicin, glucoraphanin, glucoiberin, glucoerucin, progoitrin, gluconapin, sinigrin and glucocheirolin. The linear range was 1-150 µg ml(-1), the intra-day and inter-day precision values are within 6% and 8% at the lower limit of quantification, while the overall recovery of the eight glucosinolates was 99 ± 9%. This validated method was used successfully for analysis of glucosinolates content of broccoli sprouts grown in different conditions.

  3. Gas Chromatography-Mass Spectrometry (GC-MS Analysis of Indole Alkaloids Isolated from Catharanthus roseus (L. G. Don Cultivated Conventionally and Derived from In vitro Cultures

    Directory of Open Access Journals (Sweden)

    Aneta WESOŁOWSKA

    2016-06-01

    Full Text Available Catharanthus roseus (periwinkle is a medicinal plant commonly known for its wide biological activity. In many countries different parts of this plant are used for the treatment of diabetes, hypertension and for menstrual regulation. Due to the ability of production of alkaloids, which can be applied in cancer therapy, is still extensively investigated. Two, the most valuable alkaloids (vincristine and vinblastine are present in C. roseus in very low concentrations. Micropropagation is promising technique used to enhance the level of important secondary metabolites. The main objective of present study was alkaloids extraction from plants cultivated conventionally and derived from in vitro cultures. In this order the aerial parts of periwinkle were extracted with 96% ethanol at room temperature (method I and heated with 96% ethanol at 55 °C for 90 minutes (method II. The obtained mixtures of different indole alkaloids were analyzed by gas chromatography – mass spectrometry (GC-MS. Analysis revealed the presence of 15 alkaloids, among which vindoline, vindorosine, isovindolinine and ajmalicine were the most abundant. The obtained results indicated that the propagation method had a significant effect on the percentage content of alkaloids in C. roseus herb. Plants derived from in vitro cultures were richer in vindorosine and vindoline, while conventionally cultivated – in tetrahydroalstonine and ajmalicine. Moreover, in case of isovindolinine, vindolinine and ajmalicine, extraction at 55 °C was more effective, while for pericyclivine – maceration at room temperature. Interestingly, the pericyclivine was not detected in the mixture of alkaloids obtained from periwinkle herb by the extraction at 55 °C.

  4. Factors That Contribute to Assay Variation in Quantitative Analysis of Sex Steroid Hormones Using Liquid and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Xu, Xia; Veenstra, Timothy D.

    2012-01-01

    The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…

  5. Methods of analysis and quality-assurance practices of the U.S. Geological Survey organic laboratory, Sacramento, California; determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Crepeau, Kathryn L.; Domagalski, Joseph L.; Kuivila, Kathryn M.

    1994-01-01

    Analytical method and quality-assurance practices were developed for a study of the fate and transport of pesticides in the Sacramento-San Joaquin Delta and the Sacramento and San Joaquin River. Water samples were filtered to remove suspended parti- culate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide, and the pesticides were eluted with three 2-milliliter aliquots of hexane:diethyl ether (1:1). The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for analytes determined per 1,500-milliliter samples ranged from 0.006 to 0.047 microgram per liter. Recoveries ranged from 47 to 89 percent for 12 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.05 and 0.26 microgram per liter. The method was modified to improve the pesticide recovery by reducing the sample volume to 1,000 milliliters. Internal standards were added to improve quantitative precision and accuracy. The analysis also was expanded to include a total of 21 pesticides. The method detection limits for 1,000-milliliter samples ranged from 0.022 to 0.129 microgram per liter. Recoveries ranged from 38 to 128 percent for 21 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.10 and 0.75 microgram per liter.

  6. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  7. Data preprocessing method for liquid chromatography-mass spectrometry based metabolomics.

    Science.gov (United States)

    Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S; Binkley, Joe; McClain, Craig; Zhang, Xiang

    2012-09-18

    A set of data preprocessing algorithms for peak detection and peak list alignment are reported for analysis of liquid chromatography-mass spectrometry (LC-MS)-based metabolomics data. For spectrum deconvolution, peak picking is achieved at the selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into the z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers demonstrates that the developed data preprocessing method performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS(2), for peak picking, peak list alignment, and quantification.

  8. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  9. Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    HUANG Lan-fang; WU Ming-jian; SUN Xian-jun; ZHONG Ke-jun; GUO Zi-ming; DAI Yun-hui; HUANG Ke-long; GUO Fang-qiu

    2007-01-01

    Chromatography-mass spectrometry (GC-MS) was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections (HELP). After extracting with simultaneous distillation and extraction method, the volatile components in cut tobacco were detected by GC-MS. Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms. The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST) mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response. The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra. 107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 88.01% of the total content. The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.

  10. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    Science.gov (United States)

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased.

  11. Determination of Synthetic Cathinones in Urine Using Gas Chromatography-Mass Spectrometry Techniques.

    Science.gov (United States)

    Hong, Wei-Yin; Ko, Ya-Chun; Lin, Mei-Chih; Wang, Po-Yu; Chen, Yu-Pen; Chiueh, Lih-Ching; Shih, Daniel Yang-Chih; Chou, Hsiu-Kuan; Cheng, Hwei-Fang

    2016-01-01

    In recent years, the abuse of synthetic cathinones has increased considerably. This study proposes a method, based on gas chromatography/mass spectrometry (GC-MS), to analyze and quantify six synthetic cathinones in urine samples: mephedrone (4-MMC), methylone (bk-MDMA), butylone, ethylone, pentylone and methylenedioxypyrovalerone (MDPV). In our procedure, the urine samples undergo solid-phase extraction (SPE) and derivatization prior to injection into the GC-MS device. Separation is performed using a HP-5MS capillary column. The use of selective ion monitoring (SIM mode) makes it is good sensitivity in this method, and the entire analysis process is within 18 min. In addition, the proposed method maintains linearity in the calibration curve from 50 to 2,000 ng/mL (r(2) > 0.995). The limit of detection of this method is 5 ng/mL, with the exception of MDPV (20 ng/mL); the limit of quantification is 20 ng/mL, with the exception of MDPV (50 ng/mL). In testing, the extraction performance of SPE was between 82.34 and 104.46%. Precision and accuracy results were satisfactory MDMA. Our results demonstrate the efficacy of the proposed method in the identification of synthetic cathinones in urine, with regard to the limits of detection and quantification. This method is highly repeatable and accurate. PMID:26410364

  12. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively. PMID:26427497

  13. Determination of Morphine and Codeine in Human Urine by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xiaoqian Zhang

    2013-01-01

    Full Text Available A sensitive and selective gas chromatography-mass spectrometry (GC-MS method was developed and validated for the determination of morphine and codeine in human urine. The GC-MS conditions were developed. The analysis was carried out on a HP-1MS column (30 m × 0.25 mm, 0.25 μm with temperature programming, and Helium was used as the carrier gas with a flow rate of 1.0 mL/min. Selected ion monitoring (SIM mode was used to quantify morphine and codeine. The derivation solvent, temperature, and time were optimized. A mixed solvent of propionic anhydride and pyridine (5 : 2 was finally used for the derivation at 80°C for 3 min. Linear calibration curves were obtained in the concentration range of 25–2000.0 ng/mL, with a lower limit of quantification of 25 ng/mL. The intra- and interday precision (RSD values were below 13%, and the accuracy was in the range 87.2–108.5%. This developed method was successfully used for the determination of morphine and codeine in human urine for forensic identification study.

  14. Comparison of motor oils using high-temperature gas chromatography-mass spectrometry.

    Science.gov (United States)

    Reardon, Michelle R; Allen, Lance; Bender, Edward C; Boyle, Katherine M

    2007-05-01

    The analysis of motor oils has wide applications in the forensic science field from comparing lubricants transferred between an automobile and a victim or crime scene to differentiating the compositions of plastic explosives. In this study, 40 unused motor oils were analyzed and compared by high-temperature gas chromatography-mass spectrometry to determine the potential for oil individualization. Oil samples were also collected from the crankcase dipsticks of 30 cars. Twenty-six of these oils could be differentiated from each other based on visual comparisons of the unresolved envelope (baseline rise due to incomplete separation) and the resolved hydrocarbons in the raw total ion chromatograms (TICs) and smoothed TIC data. Four of these oils were analyzed as unknowns and were correctly related to the corresponding vehicle. The use of extracted ion profiles (EIPs) was explored as a means to further discriminate between the indistinct samples based on the polycyclic aromatic hydrocarbon (PAH) content. The research discussed in this paper demonstrated that differentiation of motor oils was possible by examining the TIC, smoothed TIC, and EIP data. PMID:17456092

  15. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively.

  16. 加速溶剂萃取-气相色谱-质谱法分析土壤中多氯联苯%Analysis of PCBs in Soil by Accelerate Solvent Extraction Coupled With Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    汤桦; 陈大舟; 邵明武; 戴新华; 王覃

    2004-01-01

    An effective method for determination of polychlorinated biphenyls (PCBs) in contaminated soil by means of accelerate solvent extraction (ASE) followed with gas chromatography-mass spectrometry (GC/MS) was studied. The reliability and efficiency of ASE for extracting PCBs from contaminated soil has been investigated by comparing with soxhlet extraction. The influence of extract parameters such as temperature, static cycle were discussed. RSD was 1.8%-9.3% .The detection limits is in the range of 0.33-1.33μg/kg. The result showed the method was rapid, sensitive and economic.

  17. 白酒中乙酯类成分的气相色谱-质谱分析%Analysis of Ester in Some Spirit by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    骆传环; 黄荣清; 肖炳坤; 梁乾德

    2004-01-01

    To determine fragrance character of Spirit “Bai” from Shandong. Spirit “Lu”was positive control, “Er”, egative control, three samples were extracted with either,then analyzed qualitatively and quantitatively with ISTD N-amyl acetate (EP) by gas chromatography-mass spectrometry (GC/MS). Fragranter components including ethyl acid ester(E),butanotic acid ester (B),lactic acid ester (L), pentoic acid ester(p), and hexanoic acid ester(H) were chosen. The result showed that the level of esters were higher in Bai close to “Lu”, so “Bai” can be called concentration fragrant type spirit.

  18. Identification of potentially toxic compounds in complex extracts of environmental samples using gas chromatography-mass spectrometry and multivariate data analysis.

    Science.gov (United States)

    Bergknut, Magnus; Kucera, Adam; Frech, Kristina; Andersson, Erika; Engwall, Magnus; Rannug, Ulf; Koci, Vladimir; Andersson, Patrik L; Haglund, Peter; Tysklind, Mats

    2007-02-01

    In this study, we examined 31 samples of varying chemical composition, including samples of soils from gasworks, coke production sites, and sites where wood preservatives were heavily used; ash and soot from municipal solid waste incinerators; antiskid sand; and dust from areas with heavy road traffic. The samples were comprehensively chemically characterized, especially their polycyclic aromatic compound contents, using gas chromatography-time-of-flight mass spectrometry, whereas their biological effects were assessed using dehydrogenase activity, root growth (Hordeum vulgare), reproduction of springtails (Folsomia candida), algal growth (Desmodesmus subspicatus), germinability (Sinapis alba), Vibrio fischeri, DR-CALUX, and Ames Salmonella assays. The number of compounds detected in the samples ranged from 123 to 527. Using the multivariate regression technique of partial-least-squares projections to latent structures, it was possible to find individual compounds that exhibited strong correlations with the different biological responses. Some of the results, however, indicate that a broader chemical characterization may be needed to identify all the compounds that may cause the measured biological responses.

  19. Ultra-high sensitivity analysis of estrogens for special populations in serum and plasma by liquid chromatography-mass spectrometry: Assay considerations and suggested practices.

    Science.gov (United States)

    Wang, Qingqing; Mesaros, Clementina; Blair, Ian A

    2016-09-01

    Estrogen measurements play an important role in the clinical evaluation of many endocrine disorders as well as in research on the role of hormones in human biology and disease. It remains an analytical challenge to quantify estrogens and their metabolites in specimens from special populations including older men, children, postmenopausal women and women receiving aromatase inhibitors. Historically, immunoassays have been used for measuring estrogens and their metabolites in biological samples for risk assessment. However, the lack of specificity and accuracy of immunoassay-based methods has caused significant problems when interpreting data generated from epidemiological studies and across different laboratories. Stable isotope dilution (SID) methodology coupled with liquid chromatography-selected reaction monitoring-mass spectrometry (LC-SRM/MS) is now accepted as the 'gold-standard' to quantify estrogens and their metabolites in serum and plasma due to improved specificity, high accuracy, and the ability to monitor multiple estrogens when compared with immunoassays. Ultra-high sensitivity can be obtained with pre-ionized derivatives when using triple quadruple mass spectrometers in the selected reaction monitoring (SRM) mode coupled with nanoflow LC. In this review, we have examined the special issues related to utilizing ultra-high sensitivity SID LC-SRM/MS-based methodology to accurately quantify estrogens and their metabolites in the serum and plasma from populations with low estrogen levels. The major issues that are discussed include: sample preparation for both unconjugated and conjugated estrogens, derivatization, chromatographic separation, matrix effects, and assay validation. PMID:26767303

  20. Optimization of solid-phase extraction for the liquid chromatography-mass spectrometry analysis of harpagoside, 8-para-coumaroyl harpagide, and harpagide in equine plasma and urine.

    Science.gov (United States)

    Colas, Cyril; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves; Bouchonnet, Stéphane

    2008-02-01

    Solid-phase extraction cartridges among those usually used for screening in horse doping analyses are tested to optimize the extraction of harpagoside (HS), harpagide (HG), and 8-para-coumaroyl harpagide (8PCHG) from plasma and urine. Extracts are analyzed by liquid chromatography coupled with multi-step tandem mass spectrometry. The extraction process retained for plasma applies BondElut PPL cartridges and provides extraction recoveries between 91% and 93%, with RSD values between 8 and 13% at 0.5 ng/mL. Two different procedures are needed to extract analytes from urine. HS and 8PCHG are extracted using AbsElut Nexus cartridges, with recoveries of 85% and 77%, respectively (RSD between 7% and 19%). The extraction of HG involves the use of two cartridges: BondElut PPL and BondElut C18 HF, with recovery of 75% and RSD between 14% and 19%. The applicability of the extraction methods is determined on authentic equine plasma and urine samples after harpagophytum or harpagoside administration. PMID:18366880

  1. Proteomic analysis of prolactinoma cells by immuno-laser capture microdissection combined with online two-dimensional nano-scale liquid chromatography/mass spectrometry

    OpenAIRE

    Chen Luping; Zhuang Dongxiao; Hou Ruiping; Yan Guoquan; Wu Jinsong; Liu Yingchao; Pang Qi; Zhu Jianhong

    2010-01-01

    Abstract Background Pituitary adenomas, the third most common intracranial tumor, comprise nearly 16.7% of intracranial neoplasm and 25%-44% of pituitary adenomas are prolactinomas. Prolactinoma represents a complex heterogeneous mixture of cells including prolactin (PRL), endothelial cells, fibroblasts, and other stromal cells, making it difficult to dissect the molecular and cellular mechanisms of prolactin cells in pituitary tumorigenesis through high-throughout-omics analysis. Our newly d...

  2. Preliminary construction of integral analysis for characteristic components in complex matrices by in-house fabricated solid-phase microextraction fibers combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tang, Zhentao; Hou, Wenqian; Liu, Xiuming; Wang, Mingfeng; Duan, Yixiang

    2016-08-26

    Integral analysis plays an important role in study and quality control of substances with complex matrices in our daily life. As the preliminary construction of integral analysis of substances with complex matrices, developing a relatively comprehensive and sensitive methodology might offer more informative and reliable characteristic components. Flavoring mixtures belonging to the representatives of substances with complex matrices have now been widely used in various fields. To better study and control the quality of flavoring mixtures as additives in food industry, an in-house fabricated solid-phase microextraction (SPME) fiber was prepared based on sol-gel technology in this work. The active organic component of the fiber coating was multi-walled carbon nanotubes (MWCNTs) functionalized with hydroxyl-terminated polydimethyldiphenylsiloxane, which integrate the non-polar and polar chains of both materials. In this way, more sensitive extraction capability for a wider range of compounds can be obtained in comparison with commercial SPME fibers. Preliminarily integral analysis of three similar types of samples were realized by the optimized SPME-GC-MS method. With the obtained GC-MS data, a valid and well-fit model was established by partial least square discriminant analysis (PLS-DA) for classification of these samples (R2X=0.661, R2Y=0.996, Q2=0.986). The validity of the model (R2=0.266, Q2=-0.465) has also approved the potential to predict the "belongingness" of new samples. With the PLS-DA and SPSS method, further screening out the markers among three similar batches of samples may be helpful for monitoring and controlling the quality of the flavoring mixtures as additives in food industry. Conversely, the reliability and effectiveness of the GC-MS data has verified the comprehensive and efficient extraction performance of the in-house fabricated fiber. PMID:27457562

  3. Characterization of the Authenticity of Pasta di Gragnano Protected Geographical Indication Through Flavor Component Analysis by Gas Chromatography-Mass Spectrometry and Chemometric Tools.

    Science.gov (United States)

    Giannetti, Vanessa; Boccacci Mariani, Maurizio; Mannino, Paola

    2016-09-01

    An authentication study based on headspace solid-phase microextraction/GC-MS was performed with a set of 60 samples representative of traditional "Pasta di Gragnano protected geographical indication (PGI)" and the most common Italian pasta brands. Multivariate chemometric tools were used to classify the samples based on the chemical information provided from 20 target flavor compounds, including Maillard reaction and lipid oxidation products. Pattern recognition by principal component analysis and linear discriminant analysis showed a natural grouping of samples according to the drying process adopted for their production (i.e., the traditional Cirillo method versus a high-temperature approach). Subsequently, soft independent modeling by class analogy (SIMCA) and unequal dispersed classes (UNEQ) were used to build class models at 95% confidence and 100% sensitivity levels (forced models) for predictive classification purposes. The good performance obtained from the models in terms of cross-validation efficiency (SIMCA, 57.01%; UNEQ, 86.60%; 100% for both forced models) highlighted that targeted analysis of flavor profiles could be used to assess the authenticity of Pasta di Gragnano PGI samples. Hence, the proposed method may help to protect Pasta di Gragnano PGI from label frauds by verifying whether samples comply with statements concerning drying process conditions as stated in the product specification. PMID:27619656

  4. Increasing productivity for the analysis of trace contaminants in food by gas chromatography-mass spectrometry using automated liner exchange, backflushing and heart-cutting.

    Science.gov (United States)

    David, Frank; Tienpont, Bart; Devos, Christophe; Lerch, Oliver; Sandra, Pat

    2013-10-25

    Laboratories focusing on residue analysis in food are continuously seeking to increase sample throughput by minimizing sample preparation. Generic sample extraction methods such as QuEChERS lack selectivity and consequently extracts are not free from non-volatile material that contaminates the analytical system. Co-extracted matrix constituents interfere with target analytes, even if highly sensitive and selective GC-MS/MS is used. A number of GC approaches are described that can be used to increase laboratory productivity. These techniques include automated inlet liner exchange and column backflushing for preservation of the performance of the analytical system and heart-cutting two-dimensional GC for increasing sensitivity and selectivity. The application of these tools is illustrated by the analysis of pesticides in vegetables and fruits, PCBs in milk powder and coplanar PCBs in fish. It is demonstrated that considerable increase in productivity can be achieved by decreasing instrument down-time, while analytical performance is equal or better compared to conventional trace contaminant analysis. PMID:23891373

  5. Increasing productivity for the analysis of trace contaminants in food by gas chromatography-mass spectrometry using automated liner exchange, backflushing and heart-cutting.

    Science.gov (United States)

    David, Frank; Tienpont, Bart; Devos, Christophe; Lerch, Oliver; Sandra, Pat

    2013-10-25

    Laboratories focusing on residue analysis in food are continuously seeking to increase sample throughput by minimizing sample preparation. Generic sample extraction methods such as QuEChERS lack selectivity and consequently extracts are not free from non-volatile material that contaminates the analytical system. Co-extracted matrix constituents interfere with target analytes, even if highly sensitive and selective GC-MS/MS is used. A number of GC approaches are described that can be used to increase laboratory productivity. These techniques include automated inlet liner exchange and column backflushing for preservation of the performance of the analytical system and heart-cutting two-dimensional GC for increasing sensitivity and selectivity. The application of these tools is illustrated by the analysis of pesticides in vegetables and fruits, PCBs in milk powder and coplanar PCBs in fish. It is demonstrated that considerable increase in productivity can be achieved by decreasing instrument down-time, while analytical performance is equal or better compared to conventional trace contaminant analysis.

  6. Characterization of the Authenticity of Pasta di Gragnano Protected Geographical Indication Through Flavor Component Analysis by Gas Chromatography-Mass Spectrometry and Chemometric Tools.

    Science.gov (United States)

    Giannetti, Vanessa; Boccacci Mariani, Maurizio; Mannino, Paola

    2016-09-01

    An authentication study based on headspace solid-phase microextraction/GC-MS was performed with a set of 60 samples representative of traditional "Pasta di Gragnano protected geographical indication (PGI)" and the most common Italian pasta brands. Multivariate chemometric tools were used to classify the samples based on the chemical information provided from 20 target flavor compounds, including Maillard reaction and lipid oxidation products. Pattern recognition by principal component analysis and linear discriminant analysis showed a natural grouping of samples according to the drying process adopted for their production (i.e., the traditional Cirillo method versus a high-temperature approach). Subsequently, soft independent modeling by class analogy (SIMCA) and unequal dispersed classes (UNEQ) were used to build class models at 95% confidence and 100% sensitivity levels (forced models) for predictive classification purposes. The good performance obtained from the models in terms of cross-validation efficiency (SIMCA, 57.01%; UNEQ, 86.60%; 100% for both forced models) highlighted that targeted analysis of flavor profiles could be used to assess the authenticity of Pasta di Gragnano PGI samples. Hence, the proposed method may help to protect Pasta di Gragnano PGI from label frauds by verifying whether samples comply with statements concerning drying process conditions as stated in the product specification.

  7. Analysis of Serum Metabolic Profile by Ultra-performance Liquid Chromatography-mass Spectrometry for Biomarkers Discovery: Application in a Pilot Study to Discriminate Patients with Tuberculosis

    Directory of Open Access Journals (Sweden)

    Shuang Feng

    2015-01-01

    Full Text Available Background: Tuberculosis (TB is a chronic wasting inflammatory disease characterized by multisystem involvement, which can cause metabolic derangements in afflicted patients. Metabolic signatures have been exploited in the study of several diseases. However, the serum that is successfully used in TB diagnosis on the basis of metabolic profiling is not by much. Methods: Orthogonal partial least-squares discriminant analysis was capable of distinguishing TB patients from both healthy subjects and patients with conditions other than TB. Therefore, TB-specific metabolic profiling was established. Clusters of potential biomarkers for differentiating TB active from non-TB diseases were identified using Mann-Whitney U-test. Multiple logistic regression analysis of metabolites was calculated to determine the suitable biomarker group that allows the efficient differentiation of patients with TB active from the control subjects. Results: From among 271 participants, 12 metabolites were found to contribute to the distinction between the TB active group and the control groups. These metabolites were mainly involved in the metabolic pathways of the following three biomolecules: Fatty acids, amino acids, and lipids. The receiver operating characteristic curves of 3D, 7D, and 11D-phytanic acid, behenic acid, and threoninyl-γ-glutamate exhibited excellent efficiency with area under the curve (AUC values of 0.904 (95% confidence interval [CI]: 0863-0.944, 0.93 (95% CI: 0.893-0.966, and 0.964 (95% CI: 00.941-0.988, respectively. The largest and smallest resulting AUCs were 0.964 and 0.720, indicating that these biomarkers may be involved in the disease mechanisms. The combination of lysophosphatidylcholine (18:0, behenic acid, threoninyl-γ-glutamate, and presqualene diphosphate was used to represent the most suitable biomarker group for the differentiation of patients with TB active from the control subjects, with an AUC value of 0.991. Conclusion: The

  8. Multiresidue analysis of plant growth regulators in grapes by triple quadrupole and quadrupole-time of flight-based liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Oulkar, Dasharath P; Banerjee, Kaushik; Kulkarni, Sunil

    2011-01-01

    A selective and sensitive LC-MS/MS method is presented for simultaneous determination of 12 plant growth regulators, viz., indol-3-acetic acid, indol-3-butyric acid, kinetin, zeatin, 6-benzyl aminopurine, gibberellic acid, abscisic acid, chlormequat chloride, forchlorfenuron, paclobutrazole, daminozide, and 2,4-dichlorophenoxy acetic acid, in bud sprouts and grape berries. The sample preparation method involved extraction of homogenized sample (5 g) with 40 mL methanol (80%), and final determination was by LC-MS/MS in the multiple reaction monitoring (MRM) mode with time segmentation for quantification supported by complementary analysis by quadrupole-time of flight (Q-TOF) MS with targeted high-resolution MS/MS scanning for confirmatory identification based on accurate mass measurements. The recovery of the test compounds ranged within 90-107% with precision RSD less than 5% (n = 6). The method could be successfully applied in analyzing incurred residue samples, and the strength of accurate mass analysis could be utilized in identifying the compounds in cases where the qualifier MRM ions were absent or at an S/N less than 3:1 due to low concentrations.

  9. Metabolic Flux Analysis of Lipid Biosynthesis in the Yeast Yarrowia lipolytica Using 13C-Labled Glucose and Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Zhang, Huaiyuan; Wu, Chao; Wu, Qingyu; Dai, Junbiao; Song, Yuanda

    2016-01-01

    The oleaginous yeast Yarrowia lipolytica has considerable potential for producing single cell oil, which can be converted to biodiesel, a sustainable alternative to fossil fuels. However, extensive fundamental and engineering efforts must be carried out before commercialized production become cost-effective. Therefore, in this study, metabolic flux analysis of Y. lipolytica was performed using 13C-labeled glucose as a sole carbon source in nitrogen sufficient and insufficient media. The nitrogen limited medium inhibited cell growth while promoting lipid accumulation (from 8.7% of their biomass to 14.3%). Metabolic flux analysis showed that flux through the pentose phosphate pathway was not significantly regulated by nitrogen concentration, suggesting that NADPH generation is not the limiting factor for lipid accumulation in Y. lipolytica. Furthermore, metabolic flux through malic enzyme was undetectable, confirming its non-regulatory role in lipid accumulation in this yeast. Nitrogen limitation significantly increased flux through ATP:citrate lyase (ACL), implying that ACL plays a key role in providing acetyl-CoA for lipid accumulation in Y. lipolytica. PMID:27454589

  10. Metabolic Flux Analysis of Lipid Biosynthesis in the Yeast Yarrowia lipolytica Using 13C-Labled Glucose and Gas Chromatography-Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Huaiyuan Zhang

    Full Text Available The oleaginous yeast Yarrowia lipolytica has considerable potential for producing single cell oil, which can be converted to biodiesel, a sustainable alternative to fossil fuels. However, extensive fundamental and engineering efforts must be carried out before commercialized production become cost-effective. Therefore, in this study, metabolic flux analysis of Y. lipolytica was performed using 13C-labeled glucose as a sole carbon source in nitrogen sufficient and insufficient media. The nitrogen limited medium inhibited cell growth while promoting lipid accumulation (from 8.7% of their biomass to 14.3%. Metabolic flux analysis showed that flux through the pentose phosphate pathway was not significantly regulated by nitrogen concentration, suggesting that NADPH generation is not the limiting factor for lipid accumulation in Y. lipolytica. Furthermore, metabolic flux through malic enzyme was undetectable, confirming its non-regulatory role in lipid accumulation in this yeast. Nitrogen limitation significantly increased flux through ATP:citrate lyase (ACL, implying that ACL plays a key role in providing acetyl-CoA for lipid accumulation in Y. lipolytica.

  11. Analysis of sterols and fatty acids in natural and cultured Cordyceps by one-step derivatization followed with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, F Q; Feng, K; Zhao, J; Li, S P

    2009-07-12

    Ten free fatty acids namely lauric acid, myristic acid, pentadecanoic acid, palmitoleic acid, palmitic acid, linoleic acid, oleic acid, stearic acid, docosanoic acid and lignoceric acid and four free sterols including ergosterol, cholesterol, campesterol and beta-sitosterol in natural (wild) Cordyceps sinensis, Cordyceps liangshanensis and Cordyceps gunnii, as well as cultured C. sinensis and Cordyceps militaris were first determined using pressurized liquid extraction (PLE), trimethylsilyl (TMS) derivatization and GC-MS analysis. The conditions such as the amount of reagent, temperature and time for TMS derivatization of analytes were optimized. Under the optimum conditions, all calibration curves showed good linearity within the tested ranges. The intra- and inter-day variations for 14 investigated compounds were less than 3.4% and 5.2%, respectively. The results showed that palmitic acid, linoleic acid, oleic acid, stearic acid and ergosterol are main components in natural and cultured Cordyceps which could be discriminated by hierarchical clustering analysis based on the contents of 14 investigated compounds or the 4 fatty acids, where the contents of palmitic acid and oleic acid in natural Cordyceps are significantly higher than those in the cultured ones.

  12. Comparison of electrospray ionization and atmospheric pressure photoionization liquid chromatography mass spectrometry methods for analysis of ergot alkaloids from endophyte-infected sleepygrass (Achnatherum robustum).

    Science.gov (United States)

    Jarmusch, Alan K; Musso, Ashleigh M; Shymanovich, Tatsiana; Jarmusch, Scott A; Weavil, Miranda J; Lovin, Mary E; Ehrmann, Brandie M; Saari, Susanna; Nichols, David E; Faeth, Stanley H; Cech, Nadja B

    2016-01-01

    Ergot alkaloids are mycotoxins with an array of biological effects. With this study, we investigated for the first time the application of atmospheric pressure photoionization (APPI) as an ionization method for LC-MS analysis of ergot alkaloids, and compared its performance to that of the more established technique of electrospray ionization (ESI). Samples of the grass Achnatherum robustum infected with the ergot producing Epichloë fungus were extracted using cold methanol and subjected to reserved-phase HPLC-ESI-MS and HPLC-APPI-MS analysis. The ergot alkaloids ergonovine and lysergic acid amide were detected in these samples, and quantified via external calibration. Validation parameters were recorded in accordance with ICH guidelines. A triple quadrupole MS operated in multiple reaction monitoring yielded the lowest detection limits. The performance of APPI and ESI methods was comparable. Both methods were subject to very little matrix interference, with percent recoveries ranging from 82% to 100%. As determined with HPLC-APPI-MS quantification, lysergic acid amide and ergonovine were extracted from an A. robustum sample infected with the Epichloë fungus at concentrations of 1.143±0.051 ppm and 0.2822±0.0071 ppm, respectively. There was no statistically significant difference between these concentrations and those determined using ESI for the same samples.

  13. Analysis of α,β,γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography--mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    SUN Tong-hua; FANG Neng-hu; ZHU Nan-wen; WANG Ya-lin; JIA Jin-ping

    2004-01-01

    A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were pressented. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, long lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water.

  14. Qualitative and quantitative analysis of vetiver essential oils by comprehensive two-dimensional gas chromatography and comprehensive two-dimensional gas chromatography/mass spectrometry.

    Science.gov (United States)

    Filippi, Jean-Jacques; Belhassen, Emilie; Baldovini, Nicolas; Brevard, Hugues; Meierhenrich, Uwe J

    2013-05-01

    Vetiver essential oils (VEO) are important raw ingredients used in perfume industry, entering the formula of numerous modern fragrances. Vetiver oils are considered to be among the most complex essential oils, resulting most of the time in highly coeluted chromatograms whatever the analytical technique. In this context, conventional gas chromatography has failed to provide a routine tool for the accurate qualitative and quantitative analysis of their constituents. Applying comprehensive two-dimensional gas chromatography techniques (GC×GC-FID/MS) afforded the mean to separate efficiently vetiver oil constituents in order to identify them in a more reliable way. Moreover, this is the first time that a complete true quantitation of each constituent is carried out on such complex oils by means of internal calibration. Finally, we have studied the influence of the injection mode on the determined chemical composition, and showed that several alcohols underwent dehydration under defined chromatographic conditions (splitless mode) usually recommended for quantitation purposes. PMID:23522261

  15. A new gas chromatography/mass spectrometry method for the simultaneous analysis of target and non-target organic contaminants in waters.

    Science.gov (United States)

    Gómez, M J; Gómez-Ramos, M M; Agüera, A; Mezcua, M; Herrera, S; Fernández-Alba, A R

    2009-05-01

    In this study we developed a GC-MS method for the analysis of priority pollutants, personal care products (PCPs) and other emerging contaminants in waters using large volume injection with backflushing. Analyses are performed in the SIM/scan mode, so that in addition to the targeted organic contaminants, this method allows the simultaneous screening of non-target compounds. The scan data are analysed using Deconvolution Reporting Software (DRS) which screens the results for 934 organic contaminants. Deconvolution helps identify contaminants that are buried in the chromatogram by co-extracted materials and significantly reduces chromatographic resolution requirements, allowing shorter analysis times. All compounds have locked retention times and we can continually update and extend the mass spectral library including new compounds. Linearity and limits of detection in SIM and full-scan mode were studied. Method detection limits (MDLs) in effluent wastewater ranged in most of the cases from 1 to 36 ng/L in SIM mode and from 4 to 66 ng/L in full-scan mode; while in river water from 0.4 to 14 and 2-29 ng/L in SIM and full-scan mode, respectively. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to the screening of a large number of organic contaminants--not only to a subset of targets--in urban wastewaters from different wastewater treatment plants and also in river waters. Most of the target compounds were detected at concentration levels ranging from 11 to 8697 ng/L and from 7 to 1861 ng/L in effluent wastewater and river waters, respectively. Additionally, a group of 12 new compounds were automatically identified using the AMDIS and NIST libraries. Other compounds, such as the 4-amino musk xylene, a synthetic fragrance metabolite, which was not included in the databases, but has been manually searched in the full-scan chromatograms.

  16. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  17. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou;

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations acetone+acetoacetate levels (~25 to 8300 µM) and D-ß-hydroxybutyrate levels (~30 to 16500 µM). Recovery values varied...

  18. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  19. Gas chromatography-Mass spectrometry analysis and antibacterial activity of essential oil from aerial parts and roots of Anisomeles indica Linn

    Directory of Open Access Journals (Sweden)

    Ushir Yogesh

    2010-01-01

    Full Text Available The essential oil from the aerial part and roots of Anisomeles indica Linn. from the Toranmal forest, Maharashtra (India, was obtained by hydrodistillation after drying and grounding of the herbal material. A total of 27 components were resolved in the essential oil by GC-MS analysis, while 18 compounds were identified comparing the recorded mass spectra with the Nist 98/Nbs 75 K GC-MS library of mass spectra. The microbiological activity of the isolated essential oils was investigated as well. It was found that the essential oil shows microbiological activity on Escherichia coli, Pseudomonas aeruginosa, Bacillus pumilus and Staphylococcus aureus with a range of minimum inhibitory concentration values extended from 31.25 to 250 μg/ml. The percentage inhibition values calculated also support the minimum inhibitory concentration findings. The MBCs also performed for the same pathogens. Limonene, pinene, isobornyl acetate and eugenol can be considered as the main antimicrobial constituents in the essential oils of plants.

  20. Development of a mixed-mode solid phase extraction method and further gas chromatography mass spectrometry for the analysis of 3-alkyl-2-methoxypyrazines in wine.

    Science.gov (United States)

    López, Ricardo; Gracia-Moreno, Elisa; Cacho, Juan; Ferrreira, Vicente

    2011-02-11

    A new method for analysing 3-isopropyl-2-methoxypyrazine, 3-sec-butyl-2-methoxypyrazine and 3-isobutyl-2-methoxypyrazine in wine has been developed and applied to wine. The analytes are extracted from 25 mL of wine in a solid-phase extraction cartridge filled with 60 mg of cation-exchange mixed-mode sorbent. Analytes are recovered with triethylamine in dichloromethane and the organic extract is analysed by GC-SIM-MS using 3-isopropyl-2-ethoxypyrazine as internal standard. The detection limits of the method are in all cases under 1 ng/L, below the olfactory thresholds of the compounds in wine. The repeatability of the method is around 15% for levels in wine of 2 ng/L. Linearity is satisfactory and recoveries are in all cases close to 100% with RSD between 13% and 20%. The method has been applied to the analysis of 12 Chilean white and 8 Spanish red wines. The levels found suggest that 3-alkyl-2-methoxypyrazines can exert a significant sensory contribution to the aroma of Chilean Sauvignon Blanc wines, while most likely they play a nearly negligible role on traditional Ribera and Rioja Spanish red wines.

  1. Comparative Analysis of the Volatile Components in the Fresh Roots and Rhizomes of Curcuma wenyujin by Static Headspace Gas Chromatography Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    FANG Fang; CHENG Zhi-Hong; GUO Yin-Long; CAI Yan-Ben

    2006-01-01

    Static headspace GC-MS method coupled with H/D exchange was firstly developed to determine and identify the volatile components in the fresh root and rhizome of Curcuma wenyujin. The TIC chromatograms of 3 batches of fresh roots harvested at different time showed significant difference in the volatile components: the constitution was the same but the content of them was different. More than 60 volatile components in fresh roots (Root of C.wenyujin) and rhizomes (Rhizome of C. wenyujin) of C. wenyujin were detected, of which 51 and 48 volatile components were identified respectively. The fresh roots and rhizomes of C. wenyujin were found to have the similar volatile components. The contents of these components were calibrated by the response of β-elemene. In addition,the principal active component, β-elemene, was further confirmed and relatively quantified by its standard.γ-terpinene showed obvious allylic hydrogen/deuterium exchange using deuterium oxide which gave a new method to identify some compounds containing allylic hydrogen. At the same time, the active hydrogen compounds were also further confirmed. The results show that HS-GC-MS method is a fast, simple and efficient way for the analysis of volatile components from medical plants.

  2. Multiresidue method for the analysis of five antifouling agents in marine and coastal waters by gas chromatography-mass spectrometry with large-volume injection.

    Science.gov (United States)

    Agüera, A; Piedra, L; Hernando, M D; Fernández-Alba, A R

    2000-08-11

    A simple multiresidue method has been developed for the determination of five pesticides, commonly used as active ingredients in antifouling paints, in seawater samples. The pesticides studied were: chlorothalonil (2,4,5,6-tetrachloroisophthalonitrile), dichlofluanid (N-dimethyl-N-phenylsulphamide), Sea-Nine 211 (4,5-dichloro-2-n-octyl-4-isothazolin-3-one), Irgarol 1051 (2-methylthio-4-tert.-butylamino-6-cyclopropylamino-s-triazine) and TCMTB (2-thiocyanomethylthiobenzothiazole). The analytes were extracted from 200 ml water samples, using solid-phase extraction. A copolymer with hydrophilic-lipophilic balance was used as sorbent yielding good recoveries (82-95%) for most compounds except dichlofluanid and Sea-Nine 211 (<60%). Large volume injection (10 microl) gas chromatography and electron impact ionization MS (selected ion monitoring mode) detection enabled these compounds to be identified and quantified at the 1.2-3.0 ng/l level. Analysis of samples performed in three marinas in Almería (Spain) revealed the presence of Irgarol 1051 in all the cases, at concentration levels between 25 and 450 ng/l. PMID:10985557

  3. Biological Fingerprinting Analysis of Interaction Between Taxoids in Taxus and Microtubule Protein by Microdialysis Coupled with High-performance Liquid Chromatography/Mass Spectrometry for Screening Antimicrotubule Agents

    Institute of Scientific and Technical Information of China (English)

    LEI Xiao-yuan; KONG Liang; SU Xing-ye; GUO Ming; ZOU Han-fa

    2008-01-01

    Some natural products,such as traditional Chinese medicines(TCMs),contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies,A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography(HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus)to microtubules is reported,It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis,and they were identified as the taxoids of taxol,baccatin Ⅲ,10-deacetylbaccatin Ⅲ(10-DAB),cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples,both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated,It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP,Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated.

  4. Simultaneous determination of glucose turnover, alanine turnover, and gluconeogenesis in human using a double stable-isotope-labeled tracer infusion and gas chromatography-mass spectrometry analysis

    Energy Technology Data Exchange (ETDEWEB)

    Martineau, A.; Lecavalier, L.; Falardeau, P.; Chiasson, J.L.

    1985-12-01

    We have developed and validated a new method to measure simultaneously glucose turnover, alanine turnover, and gluconeogenesis in human, in steady and non-steady states, using a double stable-isotope-labeled tracer infusion and GC-MS analysis. The method is based on the concomitant infusion and dilution of D-(2,3,4,6,6-2H5)glucose and L-(1,2,3-13C3)alanine. The choice of the tracers was done on the basis of a minimal overlap between the ions of interest and those arising from natural isotopic abundances. Alanine was chosen as the gluconeogenic substrate because it is the major gluconeogenic amino acid extracted by the liver and, with lactate, constitutes the bulk of the gluconeogenic precursors. The method was validated by comparing the results obtained during simultaneous infusion of trace amounts of both stable isotope labeled compounds with the radioactive tracers (D-(3-3H)glucose and L-(1,2,3-14C3)alanine) in a normal and a diabetic subject; the radiolabeled tracers were used as the accepted reference procedure. A slight overestimation of glucose turnover (7.3 versus 6.8 in normal and 10.8 versus 9.2 mumol/kg min in diabetic subject) was noticed when the stable isotope-labeled tracers were used. For the basal turnover rate of alanine, similar values were obtained with both methods (6.2 mumol/kg min). For gluconeogenesis, higher values were observed in the basal state with the stable isotopes (0.42 versus 0.21 mumol/kg min); however, these differences disappeared in the postprandial period after the ingestion of a mixed meal. Despite those minor differences, the overall correlation with the reference method was excellent for glucose turnover (r = 0.87) and gluconeogenesis (r = 0.86).

  5. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group : determination of selected herbicides and their degradation products in water using solid-phase extraction and gas chromatography/mass spectrometry

    Science.gov (United States)

    Kish, J.L.; Thurman, E.M.; Scribner, E.A.; Zimmerman, L.R.

    2000-01-01

    A method for the extraction and analysis of eight herbicides and five degradation products using solid-phase extraction from natural water samples followed by gas chromatography/mass spectrometry is presented in this report. This method was developed for dimethenamid; flufenacet; fluometuron and its degradation products, demethylfluometuron (DMFM), 3-(trifluromethyl)phenylurea (TFMPU), 3-(trifluromethyl)-aniline (TFMA); molinate; norflurazon and its degradation product, demethylnorflurazon; pendamethalin; the degradation product of prometryn, deisopropylprometryn; propanil; and trifluralin. The eight herbicides are used primarily in the southern United States where cotton, rice, and soybeans are produced. The exceptions are dimethenamid and flufenacet, which are used on corn in the Midwest. Water samples received by the U.S. Geological Survey's Organic Geochemistry Research Group in Lawrence, Kansas, are filtered to remove suspended particulate matter and then passed through disposable solid-phase extraction columns containing octadecyl-bonded porous silica (C-18) to extract the compounds. The herbicides and their degradation products are removed from the column by ethyl acetate elution. The eluate is evaporated under nitrogen, and components then are separated, identified, and quantified by injecting an aliquot of the concentrated extract into a high-resolution, fused-silica capillary column of a gas chromatograph/mass spectrometer under selected-ion mode. Method detection limits ranged from 0.02 to 0.05 ?g/L for all compounds with the exception of TFMPU, which has a method detection limit of 0.32 ?g/L. The mean absolute recovery is 107 percent. This method for the determination of herbicides and their degradation products is valuable for acquiring information about water quality and compound fate and transport in water.

  6. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group-Update and Additions to the Determination of Chloroacetanilide Herbicide Degradation Compounds in Water Using High-Performance Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Lee, E.A.; Kish, J.L.; Zimmerman, L.R.; Thurman, E.

    2001-01-01

    An analytical method using high-performance liquid chromatography/mass spectrometry (HPLC/MS) was developed by the U.S. Geological Survey in 1999 for the analysis of selected chloroacetanilide herbicide degradation compounds in water. These compounds were acetochlor ethane sulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. The HPLC/MS method was updated in 2000, and the method detection limits were modified accordingly. Four other degradation compounds also were added to the list of compounds that can be analyzed using HPLC/MS; these compounds were dimethenamid ESA, dimethenamid OXA, flufenacet ESA, and flufenacet OXA. Except for flufenacet OXA, good precision and accuracy were demonstrated for the updated HPLC/MS method in buffered reagent water, surface water, and ground water. The mean HPLC/MS recoveries of the degradation compounds from water samples spiked at 0.20 and 1.0 ?g/L (microgram per liter) ranged from 75 to 114 percent, with relative standard deviations of 15.8 percent or less for all compounds except flufenacet OXA, which had relative standard deviations ranging from 11.3 to 48.9 percent. Method detection levels (MDL's) using the updated HPLC/MS method varied from 0.009 to 0.045 ?g/L, with the flufenacet OXA MDL at 0.072 ?g/L. The updated HPLC/MS method is valuable for acquiring information about the fate and transport of the parent chloroacetanilide herbicides in water.

  7. Analysis of inherited metabolic disease in Beijing by gas chromatography-mass spectrometry%气相色谱-质谱法检测遗传代谢性疾病高危患儿

    Institute of Scientific and Technical Information of China (English)

    彭薇; 张万巧; 封志纯

    2014-01-01

    Objective To learn the incidence of the inherited metabolic diseases in Beijing. Methods Urine samples were analyzed by gas chromatography-mass spectrometry(GC-MS)for inherited metabolic diseases in high risky infants in Beijing . Results Urine samples from 411 high risky infants were analyzed by gas chromatography-mass spectrometry. 269 cases (65.5%) were detected to have metabolic abnormalities, including 19 cases (4.6%) diagnosed of inherited metabolic diseases in which there were 15 cases of methylmalonic academia and 1 case each of propionic academia, hyperphenylalaninemia, urea cycle abnormality and pyroglutamic aciduria. There were 22 suspected cases (5.4%) of inherited metabolic diseases including 13 cases of lactic acidosis, 5 cases of primary glycerol aciduria, 4 cases of fatty acid metabolic disorders including 1 case each of Citrin defects, tyrosinemia, galactosemia 3-methylcrotonoyl coenzyme A carboxylase deifciency and maple syrup urine disease. There were also 228 cases (55.5%) of metabolic abnormalities, such as increasing urine levels of lactic acid, sucrose,lactose, galactose, N-acetyl tyrosine, succinic acid, dicarboxylic acid and abnormal serine/threonine ratio. Conclusions Methylmalonic academia might be the most common inherited metabolic diseases in high risky infants in Beijing. For infants with clinical manifestations but unclear etiology, GC-MS should be performed. MS-MS and gene analysis could be combined if necessary.%目的:了解北京地区遗传性代谢性疾病(IMD)的发病情况。方法利用气相色谱-质谱法(GC-MS)对IMD高危儿进行尿液化学分析。结果411例IMD高危儿中检测出代谢异常269例(65.5%),其中确诊IMD 19例(4.6%),包括甲基丙二酸血症15例,丙酸血症、高苯丙氨酸血症、尿素循环异常和焦谷氨酸尿症各1例;疑似IMD 22例(5.4%),包括乳酸血症13例,原发性甘油尿症5例,脂肪酸代谢异常4例,Citrin缺陷症、酪氨

  8. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    International Nuclear Information System (INIS)

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4 degree C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range

  9. [Determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Wang, Ghengyun; Zhang, Weiya; Li, Lixia; Shen, Yalei; Lin, Junfeng; Xie, Tangtang; Chu, Naiqing

    2014-08-01

    An effective method was established for the simultaneous determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry. Glycol ethers in leather and leather products were ultrasonically extracted at 45 °C, using ethyl acetate as the extraction solvent. The extracts were purified by solid phase extraction (SPE) columns, and then analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode. The content of each analyte was calibrated by external standard method. The limit of detection of ethylene glycol ethyl ether (EGEE) was 0. 10 mg/kg under the condition of signal to noise (S/N) of 3 and the limits of the other 11 glycol ethers were all less than 0.05 mg/kg. The spiked recoveries varied from 81. 2% to 95. 5% at three different spiked levels with the relative standard deviations (RSDs) ranged from 1.4% to 6. 6%. The proposed method is simple, rapid and accurate, with the limits of detection much less than the requirements of the Regulation Concerning Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) of European Union. It is applicable to the determination of residual glycol ethers in leather and leather products, and provides a reference for the relevant testing standards.

  10. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS) was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA). Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV) of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP) value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1) and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms

  11. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification. PMID:27313979

  12. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  13. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification. PMID:27313979

  14. Identification of Unknown Contaminants in Water Samples from ISS Employing Liquid Chromatography/Mass Spectrometry/Mass Spectrometry

    Science.gov (United States)

    Rutz, Jeffrey A.; Schultz, John R.

    2008-01-01

    Mass Spectrometry/Mass Spectrometry (MS/MS) is a powerful technique for identifying unknown organic compounds. For non-volatile or thermally unstable unknowns dissolved in liquids, liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) is often the variety of MS/MS used for the identification. One type of LC/MS/MS that is rapidly becoming popular is time-of-flight (TOF) mass spectrometry. This technique is now in use at the Johnson Space Center for identification of unknown nonvolatile organics in water samples from the space program. An example of the successful identification of one unknown is reviewed in detail in this paper. The advantages of time-of-flight instrumentation are demonstrated through this example as well as the strategy employed in using time-of-flight data to identify unknowns.

  15. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by C-18 solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Zaugg, Steven D.; Sandstrom, Mark W.; Smith, Steven G.; Fehlberg, Kevin M.

    1995-01-01

    A method for the isolation of 41 pesticides and pesticide metabolites in natural-water samples using C-18 solid-phase extraction and determination by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction columns containing octadecyl-bonded porous silica to extract the pesticides. The columns are dried using carbon dioxide or nitrogen gas, and adsorbed pesticides are removed from the columns by elution with 3.0 milliliters of hexane-isopropanol (3:1). Extracted pesticides are determined by capillary- column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 4 micrograms per liter (g/L) for most pesticides, with the exception of widely used corn herbicides--atrazine, alachlor, cyanazine, and metolachlor--which have upper concentration limits of 20 g/L. Single- operator method detection limits in reagent-water samples range from 0.001 to 0.018 g/L. Average short-term single-operator precision in reagent- water samples is 7 percent at the 0.1- and 1.0-g/L levels and 8 percent at the 0.01-g/L level. Mean recoveries in reagent-water samples are 73 percent at the 0.1- and 1.0-g/L levels and 83 percent at the 0.01-g/L level. The estimated holding time for pesticides after extraction on the solid-phase extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time.

  16. Analysis of gas chromatography - mass spectrometry in detection of pesticide residues in vegetables%GC-MS检测蔬菜有机磷农药残留的效果分析

    Institute of Scientific and Technical Information of China (English)

    齐志彩

    2012-01-01

    目的:用比较法对气相色谱-质谱法检测蔬菜农药残留的效果进行综合分析.方法:用气相色谱-质谱法对已知的5种农药标准品连续稀释计算出检出限,并随机抽取本地菜农种植的四种蔬菜进行农药残留量检测.同时用气相色谱法同步进行比较试验.结果:两种方法比较,气相色谱-质谱法具有更高的灵敏度和准确度,差异有统计学意义(P<0.05).对蔬菜残留农药的检测结果表明GC-MS在蔬菜农残检测中具有更广泛的用途.结论:GC- MS在检测蔬菜农药残留方面具有更好的效果.%Objective: To analyze the effect of gas chromatography - mass spectrometry in detection of pesticide residues in vegetables. Methods: 5 known pesticide standards were detected by GC - MS continuously after dilution to calculate the detection limit, and 4 kinds of vegetables were randomly selected for pesticide residues detection by GC - MS and GC simultaneously for comparison test. Results: Compared to GC, GC - MS had better sensitivity and accuracy, the difference of the two methods had statistical significance (P < 0. 05). GC - MS was more suitable for detection of pesticide residues in vegetables. Conclusion: Gas chromatography - mass spectrometry in the detection of pesticide residues in vegetables has better effect.

  17. Analysis of acrylonitrile, 1,3-butadiene, and related compounds in acrylonitrile-butadiene-styrene copolymers for kitchen utensils and children's toys by headspace gas chromatography/mass spectrometry.

    Science.gov (United States)

    Ohno, Hiroyuki; Kawamura, Yoko

    2010-01-01

    A headspace gas chromatography/mass spectrometry method was developed for the simultaneous determination of the residual levels of acrylonitrile (AN), 1,3-butadiene (1,3-BD), and their related compounds containing propionitrile (PN) and 4-vinyl-1-cyclohexene (4-VC) in acrylonitrile-butadiene-styrene (ABS) copolymers for kitchen utensils and children's toys. A sample was cut into small pieces, then N,N-dimethylacetamide and an internal standard were added in a sealed headspace vial. The vial was incubated for 1 h at 90 degrees C and the headspace gas was analyzed by gas chromatography/mass spectrometry. The recovery rates of the analytes were 93.3-101.8% and the coefficients of variation were 0.3-6.5%. In ABS copolymers, the levels were 0.3-50.4 microg/g for AN, ND-4.5 microg/g for PN, 0.06-1.58 microg/g for 1,3-BD, and 1.1-295 microg/g for 4-VC. The highest level was found for 4-VC, which is a dimer of 1,3-BD, and the next highest was for AN, which is one of the monomers of the ABS copolymer. Furthermore, the method was also applied to acrylonitrile-styrene (AS) copolymers and polystyrenes (PS) for kitchen utensils, and nitrile-butadiene rubber (NBR) gloves. In AS copolymers, AN and PN were detected at 16.8-54.5 and 0.8-6.9 microg/g, respectively. On the other hand, the levels in PS and NBR samples were all low. PMID:21313827

  18. 液相色谱-质谱联用技术分析环氧大豆油改性PF结构%Structure Analysis of Epoxidized Soybean Oil Modiifed Phenol Formaldehyde Resin with Liquid Chromatography-Mass Spectrometry Technology

    Institute of Scientific and Technical Information of China (English)

    赵彦芝; 周菊英; 李浩; 于畅

    2014-01-01

    Under the conditions of acid catalysis or alkaline catalysis,the epoxidized soybean oil modified phenolic compounds was synthesized by using epoxidized soybean oil to react with phenol and bisphenol A,then acid catalytic or alkaline catalytic epoxidized soybean oil modified phenol formaldehyde resin (PF) was prepared through the reaction of the compounds and formaldehyde solution. The compounds were analyzed by the liquid phase chromatography-mass spectrometry technology. From the analysis results,it is gained that phenol and bisphenol A all react with epoxidized soybean oil under the conditions of acid catalysis but bisphenol A is more easy to react with epoxidized soybean oil under the conditions of alkaline catalysis. FTIR analysis results show that the compounds synthesized under the two catalysis conditions all can react with formaldehyde for shaping epoxidized soybean oil modified PF with the body conformation. Comparing with acid catalytic epoxidized soybean oil modified PF,the heat resistance of the alkaline catalytic epoxidized soybean oil modified PF is better and the tensile strength is higher.%在酸性或碱性催化条件下,先将环氧大豆油与苯酚及双酚A反应,合成环氧大豆油改性酚类产物,然后将该产物与甲醛水溶液反应制备了酸催化或碱催化环氧大豆油改性酚醛树脂(PF)。利用液相色谱-质谱联用技术对合成的环氧大豆油改性酚类产物进行分析,发现在酸性催化条件下苯酚和双酚A均与环氧大豆油发生了反应,在碱性催化条件下双酚A更易与环氧大豆油发生反应。傅立叶变换红外光谱分析结果表明,两种催化条件下合成的环氧大豆油改性酚类产物均可与甲醛反应生成具有体型结构的环氧大豆油改性PF。相对于酸催化环氧大豆油改性PF,碱催化的耐热性更好,拉伸强度更高。

  19. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    Science.gov (United States)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to

  20. Analysis of Odorants in Marking Fluid of Siberian Tiger (Panthera tigris altaica) Using Simultaneous Sensory and Chemical Analysis with Headspace Solid-Phase Microextraction and Multidimensional Gas Chromatography-Mass Spectrometry-Olfactometry.

    Science.gov (United States)

    Soso, Simone B; Koziel, Jacek A

    2016-01-01

    Scent-marking is the most effective method of communication in the presence or absence of a signaler. These complex mixtures result in a multifaceted interaction triggered by the sense of smell. The objective was to identify volatile organic compound (VOC) composition and odors emitted by total marking fluid (MF) associated with Siberian tigers (Panthera tigris altaica). Siberian tiger, an endangered species, was chosen because its MF had never been analyzed. Solid phase microextraction (SPME) for headspace volatile collection combined with multidimensional gas chromatography-mass spectrometry-olfactometry for simultaneous chemical and sensory analyses were used. Thirty-two VOCs emitted from MF were identified. 2-acetyl-1-pyrroline, the sole previously identified compound responsible for the "characteristic" odor of P. tigris MF, was identified along with two additional compounds confirmed with standards (urea, furfural) and four tentatively identified compounds (3-methylbutanamine, (R)-3-methylcyclopentanone, propanedioic acid, and 3-hydroxybutanal) as being responsible for the characteristic aroma of Siberian tiger MF. Simultaneous chemical and sensory analyses improved characterization of scent-markings and identified compounds not previously reported in MF of other tiger species. This research will assist animal ecologists, behaviorists, and zookeepers in understanding how scents from specific MF compounds impact tiger and wildlife communication and improve management practices related to animal behavior. Simultaneous chemical and sensory analyses is applicable to unlocking scent-marking information for other species. PMID:27347921

  1. Analysis of Odorants in Marking Fluid of Siberian Tiger (Panthera tigris altaica Using Simultaneous Sensory and Chemical Analysis with Headspace Solid-Phase Microextraction and Multidimensional Gas Chromatography-Mass Spectrometry-Olfactometry

    Directory of Open Access Journals (Sweden)

    Simone B. Soso

    2016-06-01

    Full Text Available Scent-marking is the most effective method of communication in the presence or absence of a signaler. These complex mixtures result in a multifaceted interaction triggered by the sense of smell. The objective was to identify volatile organic compound (VOC composition and odors emitted by total marking fluid (MF associated with Siberian tigers (Panthera tigris altaica. Siberian tiger, an endangered species, was chosen because its MF had never been analyzed. Solid phase microextraction (SPME for headspace volatile collection combined with multidimensional gas chromatography-mass spectrometry-olfactometry for simultaneous chemical and sensory analyses were used. Thirty-two VOCs emitted from MF were identified. 2-acetyl-1-pyrroline, the sole previously identified compound responsible for the “characteristic” odor of P. tigris MF, was identified along with two additional compounds confirmed with standards (urea, furfural and four tentatively identified compounds (3-methylbutanamine, (R-3-methylcyclopentanone, propanedioic acid, and 3-hydroxybutanal as being responsible for the characteristic aroma of Siberian tiger MF. Simultaneous chemical and sensory analyses improved characterization of scent-markings and identified compounds not previously reported in MF of other tiger species. This research will assist animal ecologists, behaviorists, and zookeepers in understanding how scents from specific MF compounds impact tiger and wildlife communication and improve management practices related to animal behavior. Simultaneous chemical and sensory analyses is applicable to unlocking scent-marking information for other species.

  2. Gas Chromatography-Mass Spectrometry Analysis for Volatile Compounds in Bidens biternata by Headspace Injection%基于顶空静态进样技术的中药鬼针草挥发性成分GC-MS分析

    Institute of Scientific and Technical Information of China (English)

    李勇; 蒋海强; 巩丽丽

    2011-01-01

    目的:建立顶空静态进样快速分析鬼针草低温易挥发性成分的方法.方法:采用顶空静态加热萃取技术,提取鬼针草低温易挥发性成分,进行气相色谱-质谱(GC-MS)分析.结果:经GC-MS分析,鉴定出鬼针草中24个挥发性化学成分,其中α-蒎烯、α-人参烯含量最高,分别为25.19%,12.29%.结论:GC-MS结合顶空进样技术,分析鬼针草中的低温易挥发性化学成分信息,寻求中药气味主观认识的化学成分客观表征,为中药采集术语和采集经验的客观化研究提供科学依据,从而有效推进中药现代化的进程.%Objective:To establish a rapid analysis of volatile components in Bidens biternata by static headspace injection. Method; Using head-space injection technology,extract the volatile components,analyzed by gas chromatography-mass spectrometry(GC-MS). Result; By GC-MS, 24 volatile components can be identified,the content of a-pinene and α-panasinsen is the highest up to 30.666 0% and 14.966 5%. Conclusion; GC-MS combined with static headspace injection technology can provide the low boiling point volatile components, search the component objective characterization of the smell of traditional Chinese medicine(TCM) ,the experiment provide a scientific basis for the objective research on collection terminology and experiences of TCM and effectively promote the modernization process of TCM.

  3. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air. PMID:24370860

  4. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs

  5. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dubbels, R.; Klenke, E.; Schnakenberg, E.; Ehlers, C.; Schloot, W. [Univ. of Bremen, Center of Human Genetics and Genetic Counselling, Bremen (Germany); Reiter, R.J. [The Univ. of Texas Health Science Center at San Antonio, Dept. of Cellular and Structural Biology, San Antonio, Texas (United States); Goebel, A.; Schiware, H.W. [Gemeinschaftslabor Dr. Schiwara et al., Breman (Germany)

    1995-01-01

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs.

  6. The determination of 5-fluorouracil in human plasma by a gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A gas chromatography-mass spectrometry method for the determination of 5-fluorouracil in human plasma is described. The method involves a single extraction procedure with 10 ml of isopropanol-eth-er(20:80) solution and pentafluoro-benzylation. Samples were injected using an automatic injector, followed by separation on a nonpolar capillary column and detection with a mass selective detector(MSD). No en-dogeneous compounds were found to interfere. The detection limit, based upon an assayed plasma volume of 0.5, was 3 ng/ml. The extraction yield was found to be above 80%. Plasma 5-FU concentrations were det-ermined by this method in about 500 plasma samples from cancer patients undergoing treatment with 5-FU. This method is suitable for monitoring of 5-FU in plasma of cancer patients

  7. Capillary ion chromatography-mass spectrometry for simultaneous determination of glucosylglycerol and sucrose in intracellular extracts of cyanobacteria.

    Science.gov (United States)

    Fa, Yun; Liang, Wenhui; Cui, He; Duan, Yangkai; Yang, Menglong; Gao, Jun; Liu, Huizhou

    2015-09-15

    A capillary ion chromatography-mass spectrometry (MS) method was proposed to determine glucosylglycerol (GG), sucrose, and five other carbohydrates. MS conditions and make-up flow parameters were optimized. This method is accurate and sensitive for simultaneous analysis of carbohydrates, with mean correlation coefficients of determination greater than 0.99, relative standard deviation of 0.91-2.81% for eight replicates, and average spiked recoveries of 97.3-104.9%. Limits of detection of sodium adduct were obtained with MS detection in selected ion mode for GG (0.006mg/L), sucrose (0.02mg/L), and other carbohydrates (0.03mg/L). This method was successfully applied to determine GG and sucrose in intracellular extracts of salt-stressed cyanobacteria.

  8. Identification and quantitation of glycosidically bound aroma compounds in three tobacco types by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cai, Kai; Xiang, Zhangmin; Pan, Wenjie; Zhao, Huina; Ren, Zhu; Lei, Bo; Geng, Zhaoliang

    2013-10-11

    Glycosidically bound aroma compounds in three different types of tobacco were investigated. After isolation of extracts obtained by Amberlite XAD-2 adsorption and ethyl acetate elution, glycosides were analyzed after enzymatic hydrolysis by gas chromatography-mass spectrometry (GC-MS) or directly after trifluoroacetylated (TFA) derivatization by GC-MS in electron ionization (EI) and negative chemical ionization (NCI) mode. In total 21 bound aglycones were identified by β-glucosidase hydrolysis. These aglycones mainly consisted of C13-norisoprenoids, aromatic components and sesquiterpenoids. Additionally, with the aid of enzymatic hydrolysis, 15 β-d-glucopyranosides and 1 β-d-rutinoside were tentatively identified by TFA derivatization. TFA method was validated by repeatability and successfully employed to analyze different types of tobacco. Principal component analysis (PCA) was carried out on identified glycoside variables to visualize the difference between the tobacco types and the relationship between the glycoside variables and the tobacco types was established. PMID:24011421

  9. Headspace solid-phase microextraction for characterization of fragrances of lemon verbena (Aloysia triphylla) by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Nam-Sun; Lee, Dong-Sun

    2004-01-01

    Natural fragrances from lemon verbena (Aloysia triphylla) were studied by headspace solid phase microextraction (HS-SPME) techniques followed by gas chromatography-mass spectrometry (GC-MS), with six different fibre coatings being tested to evaluate the extraction efficiencies of several selected compounds. A total of 14 compounds were identified in the fragrances of lemon verbena. Geranial and neral were detected as major components and alpha-pinene, beta-pinene, beta-caryophyllene, and curcumene as minor components. Enantiomeric analysis of chiral compounds from lemon verbena was carried out on a chiral column. alpha-Pinene, limonene, and camphor in the fragrances emitted from lemon verbena were found in the (+), (-), and (-) forms, respectively. PMID:15335064

  10. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared t

  11. THE DETERMINATION OF DELTA-5-ANDROSTENEDIOL AND ITS SULFATE IN SERUM AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    DIKKESCHEI, LD; WOLTHERS, BG; WILLEMSE, PHB; VANDERPOL, H; DERUYTERBUITENHUIS, AW; NAGEL, GT

    1993-01-01

    OBJECTIVES We developed an assay for delta-5-androstenediol (adiol) and delta-5-androstenediol-3-sulphate (adiol-3S) in serum and adiol and total adiol sulphate (adiol-S) in urine. DESIGN An analytical procedure using HPLC and gas chromatography-mass spectrometry was devised and tested for its relia

  12. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    N.A. Dang; M. Mourão; S. Kuijper; E. Walters; H.-G. Janssen; A.H.J. Kolk

    2015-01-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in b

  13. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory method

  14. Different comparison analysis of lipstick and nail polish by microscopic spectrophotometry and gas chromatography-mass spectrometry%化妆品痕迹物证差异性的比对分析

    Institute of Scientific and Technical Information of China (English)

    吴国萍

    2014-01-01

    The comparison analysis of different lipstick and nail polish was studied by using microscopic spectrophotometry( MISP) and gas chromatography-mass spectrometry(GC-MS). Twenty-one similar color lipstick samples of different brands were collected from the same factory. Thirty nail polish of different factory were divided into three categories based on color. The MISP spectra were used for chromatic aberration calculation to distinguish the chromaticity of the samples. GC-MS were used for total ion chromato-grams to distinguish the component of the samples with similarΔE. GC-MS were used for structural formula and mass chromatogram of specified impurity to distinguish the component of the samples with similar ΔE and similar total ion chromatograms. 210 data of chromatic aberration(ΔE) between each pair of lipstick samples were obtained and only 5 samples whose chromaticities were less than 1. 5. 147 data of chromatic aberration(ΔE) between each pair of nail polish samples were obtained and only 6 samples whose chromaticities were less than 1. 5. It was found that similar ΔE was observed for samples with low similarity of total ion chromato-grams,while similar ΔE and similar total ion chromatograms were observed for samples with low similarity of structural formula and mass chromatogram of specified impurity. Thereby, the lipstick and nail polish can be identified according to the above informa-tions. It provided a new method for comparison analysis of different lipstick and nail polish.%本文以口红和指甲油为研究对象,共收集了21个同一品牌不同型号颜色相近的口红样本和30个三种颜色、不同品牌不同型号的指甲油样本。使用显微分光分光度计测定样本的色度数据并结合色度学理论计算色差;使用气质联用法对色差很小样本的总离子流图进行比对分析和结构解析,并进一步对总离子流图差异较小的样本选择邻苯二甲酸酯这类特定杂质结构

  15. Multiple Reaction Monitoring Mode Based Liquid Chromatography-Mass Spectrometry Method for Simultaneous Quantification of Brassinolide and Other Plant Hormones Involved in Abiotic Stresses

    OpenAIRE

    Deepak M. Kasote; Ritesh Ghosh; Jun Young Chung; Jonggeun Kim; Inhwan Bae; Hanhong Bae

    2016-01-01

    Plant hormones are the key regulators of adaptive stress response. Abiotic stresses such as drought and salt are known to affect the growth and productivity of plants. It is well known that the levels of plant hormones such as zeatin (ZA), abscisic acid (ABA), salicylic acid (SA), jasmonic acid (JA), and brassinolide (BR) fluctuate upon abiotic stress exposure. At present, there is not any single suitable liquid chromatography-mass spectrometry (LC-MS) method for simultaneous analysis of BR a...

  16. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  17. Analysis and Determmination of Fatty Acid in Donkey Milk Powder by Gas Chromatography - Mass Spectrometry%气质联用技术分析测定驴奶粉中脂肪酸

    Institute of Scientific and Technical Information of China (English)

    钱宗耀; 刘河疆; 王建梅; 周晓龙

    2012-01-01

    [Method]The aim was to analyze and determine the chemical constituents and contents of fatty acid in donkey milk powder.[Method]The chemical constituents of donkey milk powder fatty acid was analyzed and determined by gas chromatography-mass spectrometry technique.[Result]There are thirty fatty acids in donkey milk powder,among which the content of unsaturated fatty acid reaches 60.0%.[Conclusion]The study provides references for the rapid and accurate determination of fatty acid contents in milk powder,and the further development of donkey milk powder prodocts.%[目的]分析测定驴奶粉中的脂肪酸类化学成分和含量.[方法]采用气相色谱-质谱联用技术对驴奶粉中全部脂肪酸的化学成分进行分析与测定.[结果]驴奶粉中含有30多种脂肪酸,其中不饱和脂肪酸约占总脂肪酸含量的60%.[结论]该研究可为快速、准确测定奶粉中脂肪酸含量和进一步开发驴奶粉产品提供参考.

  18. Analysis of Common Volatile Components in Different Batchs of Saffron by Gas Chromatography-Mass Spectrometry%藏红花挥发油共有组分的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    隋吴彬

    2011-01-01

    The volatile components in saffron were detected by gas chromatography-mass spectrometry to compare the volatile components and contents in different batches of saffron from the same origin. The relative contents of each component were determined by peak area normalization, and the volatile components variation of different batches of saffron was investigated. As a result, 42 components were identified and certain similarity has been found in different batches of saffron from the same origin.%本文采用气相色谱-质谱(GC-MS)法分析不同批次的藏红花挥发性成分,探讨同一产地不同批次藏红花挥发组分的成分与含量,并用峰面积归一化法确定各成分的相对含量,以其中的主要挥发组分作为考察指标,观察不同批次藏红花挥发组分的变化情况.初步鉴定出42种成分,且同一产地不同批次藏红花挥发性成分具有一定相似性.

  19. Method of analysis and quality-assurance practices by the U.S. Geological Survey Organic Geochemistry Research Group; determination of geosmin and methylisoborneol in water using solid-phase microextraction and gas chromatography/mass spectrometry

    Science.gov (United States)

    Zimmerman, L.R.; Ziegler, A.C.; Thurman, E.M.

    2002-01-01

    A method for the determination of two common odor-causing compounds in water, geosmin and 2-methylisoborneol, was modified and verified by the U.S. Geological Survey's Organic Geochemistry Research Group in Lawrence, Kansas. The optimized method involves the extraction of odor-causing compounds from filtered water samples using a divinylbenzene-carboxen-polydimethylsiloxane cross-link coated solid-phase microextraction (SPME) fiber. Detection of the compounds is accomplished using capillary-column gas chromatography/mass spectrometry (GC/MS). Precision and accuracy were demonstrated using reagent-water, surface-water, and ground-water samples. The mean accuracies as percentages of the true compound concentrations from water samples spiked at 10 and 35 nanograms per liter ranged from 60 to 123 percent for geosmin and from 90 to 96 percent for 2-methylisoborneol. Method detection limits were 1.9 nanograms per liter for geosmin and 2.0 nanograms per liter for 2-methylisoborneol in 45-milliliter samples. Typically, concentrations of 30 and 10 nanograms per liter of geosmin and 2-methylisoborneol, respectively, can be detected by the general public. The calibration range for the method is equivalent to concentrations from 5 to 100 nanograms per liter without dilution. The method is valuable for acquiring information about the production and fate of these odor-causing compounds in water.

  20. Adulteration and Quality Analysis of Olive Oil by Near-Infrared Spectrometry and Gas Chromatography-Mass Spectrometry%近红外光谱和气相色谱-质谱联用技术对橄榄油掺杂及品质分析研究

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    分别采用近红外光谱技术及气相色谱-质谱联用技术对橄榄油样品进行分析。采用透射方式采集橄榄油样品的近红外光谱比漫反射方式可以获得更好的重现性;通过直观分析、二阶求导以及主成分分析可快速判别橄榄油与掺杂橄榄油。0.10 g橄榄油样品经过10 mL的KOH-甲醇溶液甲酯化处理后,加入10 mL正己烷和10 mL水进行液液萃取,并对正己烷提取液进行气相色谱-质谱分析,对39种橄榄油脂肪酸甲酯含量的分析结果与近红外光谱的主成分分析图对比得出,油酸和亚油酸是影响橄榄油近红外光谱扫描结果的主要成分。%Olive oil was analyzed by near-infrared spectrometry and gas chromatography-mass spectrometry.The reproducibility of near-infrared spectrum acquired through transmission is better than that acquired through diffuse reflection.The adulteration of olive oil was differentiated rapidly by visual analysis,derivation of two order analysis and principal component analysis(PCA).0.10 g of olive oil was added 10 mL of KOH-methanol to methyl-etherification.Then 10 mL of n-hexane and 10 mL of water were added to liquid-liquid extraction.The extracts of n-hexane were analyzed by gas chromatography-mass spectrometry and the fatty acid methyl ester(FAME) of 39 olive oil samples were compared with the PCA of near-infrared spectrometry.The results indicated that oleic acid and linoleic acid were major impact components to the near-infrared spectrums of olive oil.

  1. Determination of terpenes in tequila by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Capella, Santiago; Juárez, Rocío; Labastida, Carmen

    2006-11-17

    Solid phase microextraction and capillary gas chromatography-mass spectrometry were used for the determination of seven terpenes in tequila. The method was selected based on the following parameters: coating selection (PA, PDMS, CW/DVB, and PDMS/DVB), extraction temperature, addition of salt, and extraction time profile. The extraction conditions were: PDMS/DVB fiber, Headspace, 100% NaCl, 25 degrees C extraction temperature, 30 min extraction time and stirring at 1200 rpm. The calibration curves (50-1000 ng/ml) for the terpenes followed linear relationships with correlation coefficients (r) greater than 0.99, except for trans,trans-farnesol (r = 0.98). RSD values were smaller than 10% confirmed that the technique was precise. Samples from 18 different trade brands of "Aged" tequila analyzed with the developed method showed the same terpenes in different concentrations. The analytical procedure used is selective, robust (more than 100 analyses with the same fiber), fast and of low-cost.

  2. Postmortem interval estimation: a novel approach utilizing gas chromatography/mass spectrometry-based biochemical profiling.

    Science.gov (United States)

    Kaszynski, Richard H; Nishiumi, Shin; Azuma, Takeshi; Yoshida, Masaru; Kondo, Takeshi; Takahashi, Motonori; Asano, Migiwa; Ueno, Yasuhiro

    2016-05-01

    While the molecular mechanisms underlying postmortem change have been exhaustively investigated, the establishment of an objective and reliable means for estimating postmortem interval (PMI) remains an elusive feat. In the present study, we exploit low molecular weight metabolites to estimate postmortem interval in mice. After sacrifice, serum and muscle samples were procured from C57BL/6J mice (n = 52) at seven predetermined postmortem intervals (0, 1, 3, 6, 12, 24, and 48 h). After extraction and isolation, low molecular weight metabolites were measured via gas chromatography/mass spectrometry (GC/MS) and examined via semi-quantification studies. Then, PMI prediction models were generated for each of the 175 and 163 metabolites identified in muscle and serum, respectively, using a non-linear least squares curve fitting program. A PMI estimation panel for muscle and serum was then erected which consisted of 17 (9.7%) and 14 (8.5%) of the best PMI biomarkers identified in muscle and serum profiles demonstrating statistically significant correlations between metabolite quantity and PMI. Using a single-blinded assessment, we carried out validation studies on the PMI estimation panels. Mean ± standard deviation for accuracy of muscle and serum PMI prediction panels was -0.27 ± 2.88 and -0.89 ± 2.31 h, respectively. Ultimately, these studies elucidate the utility of metabolomic profiling in PMI estimation and pave the path toward biochemical profiling studies involving human samples. PMID:26931122

  3. Identification of tartary buckwheat tea aroma compounds with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Qin, Peiyou; Ma, Tingjun; Wu, Li; Shan, Fang; Ren, Guixing

    2011-08-01

    Tartary buckwheat tea, which is an important and healthy product, has a distinct malty aroma. However, its characteristic aroma compounds have not been elucidated. The aims of present study were identification and quantification of its aroma compounds. The analyses were performed by gas chromatography-mass spectrometry (GC-MS) after 3 different isolation techniques. Seventy-seven compounds were identified. Among these compounds, 35 were quantified by available standards. The compounds with a high probability of contribution to the tartary buckwheat tea aroma (OAV ≥ 10) were as follows: 2,5-dimethyl-4-hydroxy-3(2H)-furanone, nonanal, 2,3-diethyl-5-methylpyrazine, benzeneacetaldehyde, maltol, 2,5-dimethylpyrazine, 2-ethyl-5-methylpyrazine, trimethylpyrazine. Some nutritional and bioactive compounds were also identified in this study, such as linoleic acid, niacin, vanillic acid, 7-hydroxycoumarin, butylated hydroxytoluene. Practical Application: Tartary buckwheat, one type of buckwheat, has gained much attention from nutritionists and medical doctors in recent years. It is rich in rutin, quercetin, and other nutrients that are good for health. Tartary buckwheat-based product such as tartary buckwheat tea is an important and popular healthy product in China, Japan,South Korea, European countries as well as in American countries. It has a distinct malty aroma. The present study first identified and quantified of its aroma compounds. The results will draw attention to other researchers in food flavor and buckwheat filed. PMID:22417522

  4. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  5. Presence of phthalate esters in intravenous solution evaluated using gas chromatography-mass spectrometry method.

    Science.gov (United States)

    Strac, Ivona Vidić; Pušić, Maja; Gajski, Goran; Garaj-Vrhovac, Vera

    2013-03-01

    Di-(2-ethylhexyl) phthalate (DEHP) is a plasticizer widely used in the production of poly-(vinyl) chloride (PVC) materials. It is a reproductive and developmental toxicant in animals and a suspected endocrine modulator in humans. DEHP is not covalently bound within the PVC molecule, which is why migration into a suitable medium can be expected. Since application of infusion solutions is one of the most common medical treatments, the objective of this study was to determine the migration of phthalates from softened PVC storage bags into infusion solution in different time periods within one year from date of production using a gas chromatography-mass spectrometry method. The measured values of DEHP ranged between 0.22 and 14.00 µg l(-1) , but the unexpected presence of other phthalate esters was also detected. It was concluded that values obtained in infusion solutions match the reference data and represent a minor risk for the patient. The presence of other phthalate esters leads to the conclusion that the pharmacopeic requirement for polymer cleanness was not fully met. Since phthalate esters are among the most extensively used industrial chemicals and are widely distributed in the environment, special precautions and further monitoring should be conducted to minimize any possible health risks. PMID:22034089

  6. Discriminating Hodgdon Pyrodex(®) and Triple Seven(®) using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Routon, Benjamin J; Kocher, Brandon B; Goodpaster, John V

    2011-01-01

    Pyrodex(®) and Triple Seven(®) are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex(®) contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven(®) lacks sulfur but also contains 3-nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography-mass spectrometry. Each derivative was clearly resolved from other components, and high-quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.

  7. Metabolic Profiling and Quantification of Neurotransmitters in Mouse Brain by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Jäger, Christian; Hiller, Karsten; Buttini, Manuel

    2016-01-01

    Metabolites are key mediators of cellular functions, and have emerged as important modulators in a variety of diseases. Recent developments in translational biomedicine have highlighted the importance of not looking at just one disease marker or disease inducing molecule, but at populations thereof to gain a global understanding of cellular function in health and disease. The goal of metabolomics is the systematic identification and quantification of metabolite populations. One of the most pressing issues of our times is the understanding of normal and diseased nervous tissue functions. To ensure high quality data, proper sample processing is crucial. Here, we present a method for the extraction of metabolites from brain tissue, their subsequent preparation for non-targeted gas chromatography-mass spectrometry (GC-MS) measurement, as well as giving some guidelines for processing of raw data. In addition, we present a sensitive screening method for neurotransmitters based on GC-MS in selected ion monitoring mode. The precise multi-analyte detection and quantification of amino acid and monoamine neurotransmitters can be used for further studies such as metabolic modeling. Our protocol can be applied to shed light on nervous tissue function in health, as well as neurodegenerative disease mechanisms and the effect of experimental therapeutics at the metabolic level. © 2016 by John Wiley & Sons, Inc. PMID:27584556

  8. Quantification of busulfan in plasma by gas chromatography-mass spectrometry following derivatization with tetrafluorothiophenol.

    Science.gov (United States)

    Quernin, M H; Poonkuzhali, B; Montes, C; Krishnamoorthy, R; Dennison, D; Srivastava, A; Vilmer, E; Chandy, M; Jacqz-Aigrain, E

    1998-05-01

    A specific and highly sensitive method has been developed for the determination of busulfan in plasma by gas chromatography-mass spectrometry using a deuterium-labeled busulfan (busulfan-d8) as internal standard. Plasma containing busulfan and busulfan-d8 were extracted with ethyl acetate and derivatized with 2,3,5,6-tetrafluorothiophenol prior to the monitoring of specific ions. The limit of quantification of the assay was 20 ng/ml and the calibration curve was linear over the range of 10 to 2000 ng/ml of derivatized busulfan. This method was in good agreement with the GC-MS assay using derivatization with sodium iodide and measuring diiodobutane. In addition, a pharmacokinetic study of busulfan was conducted in six children. The apparent oral clearance was 5.7+/-1.9 ml/kg/min and the volume of distribution was 1.0+/-0.4 l/kg and were similar to those previously reported in pediatric patients.

  9. Enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Hasegawa, Takashi; Takahashi, Kazunaga; Fukiwake, Tomohide; Saijo, Masaaki; Motoki, Yuji

    2013-01-01

    We developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens. L- and D-DOPA were ultrasonically extracted with 1% formic acid aqueous solution. The isolated extracts were analyzed by LC/MS using a Crownpak CR (-) column at 30℃. The mass spectrometer was operated in the positive mode of electrospray ionization, and the mobile phase was aqueous formic acid (pH 2.0). L-DOPA-ring-d3 was used as an internal standard. The method was validated for a dietary supplement spiked with L- and D-DOPA at 50 and 500 μg/g, respectively, and the recoveries of the DOPA enantiomers were between 97.5% and 101.3%. Relative standard deviation values of repeatability and intermediate precision were less than 7%. The method was applied to 14 dietary supplements. L-DOPA was detected in these supplements in the range of 0.88-12.8 mg/unit. D-DOPA was not detected. PMID:24190293

  10. [Identification of Kweichow Moutai liquor by gas chromatography-mass spectrometry fingerprint].

    Science.gov (United States)

    Sun, Qiran; Xiang, Ping; Shen, Baohua; Shen, Min

    2010-09-01

    The fingerprint of Kweichow Moutai liquor was established by gas chromatography-mass spectrometry (GC-MS) and the similarity of fingerprints was evaluated by the fingerprint similarity calculation software designed by Zhejiang University based on included angle cosine. One milliliter of liquor sample was mixed with ten microliter of 2% n-pentyl acetate solution used as internal standard. One microliter of the prepared sample was injected into a GC-MS. The separation was performed on an HP-INNOWAX 19091N-113 capillary column. The precision and repeatability of the method were good as the relative standard deviation (RSD) of intrabatch was less than 5%. A total of 35 characteristic components of Kweichow Moutai liquor were identified. The fingerprints of 38 batches of Kweichow Moutai, 5 Moutai-flavor liquors produced by Kweichow Moutai Company Limited, the same manufacturer as Kweichow Moutai, and 12 other brand liquors were compared in characteristic components and similarity. The results demonstrated that different batches of Kweichow Moutai had good similarity (> or = 0.9), and Kweichow Moutai was differentiated from the liquors of different alcohol contents and flavors, but it was poorly distinguished from the Moutai-flavor liquors by fingerprint similarity calculation software. Therefore, only in combining characteristic components and fingerprint similarity results, Kweichow Moutai can be distinguished from other liquors. The established method offers technical basis for the identification of Kweichow Moutai. PMID:21171278

  11. Determination of phthalate esters in teas and tea infusions by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Liping; Ma, Lijuan; Qiao, Yang; Lu, Yan; Xiao, Dongguang

    2016-04-15

    Phthalate esters (PAEs), a group of environmental pollutants which are carcinogenic to human body, have been detected in teas. In this work, five PAEs in teas and tea infusions were quantitatively determined by a modified simultaneous distillation extraction (SDE) coupled with gas chromatography-mass spectrometry. After the optimization of SDE, the proposed method afforded a wide range of linearity and high linear regression coefficients with the limits of detection range of 0.24-3.72 μg/kg. The average recoveries were 79.83-116.67% for tea samples and 78.22-101.64% for tea infusions with all the relative standard deviations below 20%. The total content of five PAEs in teas was 1.135-3.734 mg/kg and the total dissolving ratio of five PAEs from tea to infusion was 19.05-28.07% for the selected tea samples. The risk assessment result of all the selected tea samples demonstrated that the population with the habit of drinking tea won't cause risk to human health.

  12. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  13. Bioassay- and liquid chromatography/mass spectrometry-guided acetylcholinesterase inhibitors from Picriafel-terrae

    Directory of Open Access Journals (Sweden)

    Lu Wen

    2013-01-01

    Full Text Available Background: Picria fel-terrae is a traditional Chinese medicine. Materials and Methods: A new approach to the search for acetylcholinesterase (AChE inhibitors from Picria fel-terrae is presented. Results: Bioassay- and LC-MS-guided fractionation of the ethyl acetate extract was from traditional Chinese medicine P.fel-terrae. Following primary extraction, the ethyl acetate extracts fraction of P.fel-terrae showed strong AChE inhibitory activities. So the sample was separated using highperformance liquid chromatography (HPLC. The effluent was split towards two identical 96-well fraction collectors, and the presence of the biologically interesting portion and chromatographic fractions could be readily detected by analyzing selected ion chromatograms through an electrophoresis-electrospray ionization mass spectrometry (ESIMS system for accurate mass measurement. One 96-well plate was used for a bioassay (AChE-inhibitory assay and detected the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate was used for identification by LC-(+ ESIMS. Conclusion: As abovementioned, the AChE inhibitory constituents from P.fel-terrae by LC-bioassay-ESIMS were rapid identified. Liquid chromatography/ mass spectrometry (LC-MS screening detected the presence of six active compounds, identified as picfeltarraenin IA (1, picfeltarraenin IB (2, picfeltarraenin IV (3, picfeltarraenin X (4, picfeltarraenin XI (5, and one unknown compound. The structures were further determined by 13C NMR. The six compounds expressed stronger AChE inhibition than the known AChE inhibitorTacrine. Above all, the value of this LC-bioassay-ESIMS methodology is highlighted by the finding and structure elucidation of the active constituents from many other structural families of natural products.

  14. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Wastewater Compounds by Polystyrene-Divinylbenzene Solid-Phase Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.; Barber, Larry B.; Burkhardt, Mark R.

    2002-01-01

    A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides. Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent ? 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

  15. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  16. Analysis of phenolic compounds by high-performance liquid chromatography and liquid chromatography/mass spectrometry in potato plant flowers, leaves, stems, and tubers and in home-processed potatoes.

    Science.gov (United States)

    Im, Hyon Woon; Suh, Bong-Soon; Lee, Seung-Un; Kozukue, Nobuyuki; Ohnisi-Kameyama, Mayumi; Levin, Carol E; Friedman, Mendel

    2008-05-14

    Potato plants synthesize phenolic compounds as protection against bruising and injury from bacteria, fungi, viruses, and insects. Because antioxidative phenolic compounds are also reported to participate in enzymatic browning reactions and to exhibit health-promoting effects in humans, a need exists for accurate methods to measure their content in fresh and processed potatoes. To contribute to our knowledge about the levels of phenolic compounds in potatoes, we validated and used high-performance liquid chromatography and liquid chromatography/mass spectrometry to measure levels of chlorogenic acid, a chlorogenic isomer, and caffeic acid in flowers, leaves, stems, and tubers of the potato plant and in home-processed potatoes. The total phenolic acid content of flowers (626 mg/100 g fresh wt) was 21 and 59 times greater than that of leaves and stems, respectively. For all samples, chlorogenic acid and its isomer contributed 96-98% to the total. Total phenolic acid levels (in g/100 g fresh wt) of peels of five potato varieties grown in Korea ranged from 6.5 to 42.1 and of the flesh (pulp) from 0.5 to 16.5, with peel/pulp ratios ranging from 2.6 to 21.1. The total phenolic acid content for 25 American potatoes ranged from 1.0 to 172. The highest amounts were present in red and purple potatoes. Home processing of pulp with various forms of heat induced reductions in the phenolic content. The described methodology should facilitate future studies on the role of potato phenolic compounds in the plant and the diet. PMID:18386928

  17. [Simultaneous determination of 16 organic acids in feed additives by on-line enrichment and ion chromatography-mass spectrometry].

    Science.gov (United States)

    Xiong, Zhiyu; Dong, Ying; Zhou, Hongbin; Yu, Yang; Li, Jing; Sun, Li

    2014-02-01

    A novel analytical method for simultaneous determination of sixteen organic acids by on-line enrichment and ion chromatography-mass spectrometry (IC-MS) was developed. Online enrichment and separation of the organic acids were performed by ion chromatography on a homemade enrichment column and a homemade separation column. The qualitative and quantitative analyses of the organic acids were performed by mass spectrometry in selected ion monitoring (SIM) mode on the basis of atmospheric pressure chemical ionization (APCI) source in negative mode. The sample of 200 microL was injected for the analysis, and the on-line enrichment time was 3 min. The sodium hydroxide solution was used as a gradient elution system. The two columns made it possible to have a low limit of detection due to the good enrichment and separation capability. The sixteen organic acids were separated completely within 30 min. All curves showed good linearity within the test concentration ranges. The limits of detection (LODs) were between 0.01 and 0.22 mg/L, and the average recoveries were between 70.6% and 110.8%. The relative standard deviations (RSDs) were less than 6.3%. The results indicate that this method is simple, rapid, sensitive and accurate for the determination of the organic acids in feed additives.

  18. Detection of 2-eicosanol by gas chromatography-mass spectrometry in sputa from patients with pulmonary mycobacterial infections.

    OpenAIRE

    Alugupalli, S; Olsson, B; Larsson, L.

    1993-01-01

    A total of 96 sputum specimens from patients with suspected or known mycobacterial and nonmycobacterial pulmonary infections were analyzed by gas chromatography-mass spectrometry for the presence of 2-eicosanol. This secondary alcohol was detected in all of the 25 sputum specimens culture positive for Mycobacterium tuberculosis, in 7 of the 9 sputum specimens culture positive for M. avium complex, and in all 3 of the studied sputum specimens associated with M. malmoense. The alcohol was not d...

  19. Development of a Gas Chromatography-Mass Spectrometry Method for the Quantification of Glucaric Acid Derivatives in Beverage Substrates

    OpenAIRE

    Ana Paula Craig; Fields, Christine C.; Simpson, John V.

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method using the standard addition methodology was developed for the determination of glucuronolactone (GL) and glucuronic acid (DGuA) in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) and TMCS (trimethylchlorosilane) to silylate the analytes. The sample pretreatment required no extraction, filtrat...

  20. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    OpenAIRE

    Maryam Zokaei; Marzieh Kamankesh; Saeideh Shojaei; Abdorreza Mohammadi

    2016-01-01

    Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatizat...

  1. Urine Mescaline Screening With a Biochip Array Immunoassay and Quantification by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Battal, Dilek; Barnes, Allan J; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-12-01

    Mescaline, the primary psychoactive chemical in peyote cactus, has been consumed for thousands of years in ancient religious ceremonies. The US military wanted to determine if mescaline intake was a problem for personnel readiness. Twenty thousand seventeen urine specimens negative for cannabinoids, cocaine, opiates, and amphetamines were tested for mescaline with the Randox Drugs of Abuse V (DOA-V) biochip array immunoassay at the manufacturer's recommended cutoff of 6 mcg/L. A sensitive and specific method for mescaline quantification in urine was developed and fully validated. Extracted analytes were derivatized with pentafluoropropionic anhydride and pentafluoropropanol and quantified by gas chromatography-mass spectrometry (GC/MS) with electron impact ionization. Standard curves, using linear least squares regression with 1/x weighting, were linear from 1 to 250 mcg/L with coefficients of determination >0.994. Intra- and inter-assay imprecision was 90.4%. Mean extraction efficiencies were >92.0% across the linear range. This fully validated method was applied for the confirmation of urinary mescaline in 526 presumptive-positive specimens and 198 randomly selected presumptive-negative specimens at the manufacturer's 6 mcg/L cutoff. No specimen confirmed positive at the GC/MS limit of quantification of 1 mcg/L. Results indicated that during this time frame, there was insufficient mescaline drug use in the military to warrant routine screening in the drug testing program. However, mescaline stability, although assessed, could have contributed to lower prevalence. We also present a validated GC/MS method for mescaline quantification in urine for reliable confirmation of suspected mescaline intake.

  2. Determination of endogenous ethanol in blood and breath by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jones, A W; Mårdh, G; Anggård, E

    1983-01-01

    We describe methods for the determination of endogenous ethanol in biological specimens from healthy abstaining subjects. The analytical methods were headspace gas chromatography (GC) for plasma samples and gas chromatography-mass spectometry (GC/MS) with deuterium labelled species 2H3-ethanol and 2H5-ethanol as internal standards for breath analysis. Ethanol in rebreathed air was about 10% higher than in directly analysed end-expired alveolar air. Known volumes of rebreathed air were passed through a liquid-N2 freeze trap and the volatile constituents of breath were concentrated prior to analysis by GC or GC/MS. Besides endogenous ethanol, peaks were seen on the chromatograms for methanol, acetone and acetaldehyde as well as several as yet unidentified substances. The endogenous alcohols ethanol and methanol were confirmed from their mass chromatograms and the GC/MS profile also indicated the presence of endogenous propan-1-ol. The concentration of endogenous ethanol in plasma showed wide inter-subject variations ranging from below detection limits to 1.6 micrograms/ml (34.8 mumol/l) and with mean +/- SD of 0.39 +/- 0.45 micrograms/ml (8.5 +/- 9.8 mumol/l). We aim to characterise further the role of endogenous ethanol with the main focus on dynamic aspects such as the rate of formation and turnover.

  3. Metabolomic Profile Analysis of Human Follicular Fluid in Repeated IVF Failure Patients Using Gas Chromatography/Mass Spectrometry%反复IVF失败患者卵泡液代谢组学的检测分析

    Institute of Scientific and Technical Information of China (English)

    夏兰; 胡双纲; 赵晓明; 孙赟; 洪燕; 郑菊芬; 向祖琼; 姚宁; 赵磊文; 郭毅

    2012-01-01

    目的:探讨与卵子发育潜能相关的代谢物质.方法:运用气相色谱-质谱仪(GC-MS)回顾性分析13例反复IVF失败(RIF组)和15例同期第1次行IVF-ET成功妊娠患者(对照组)的卵泡液代谢组学.结果:用偏最小二乘法分析样本主成分,结果显示RIF组和对照组的主成分积分值集中分布于2个不同区域,且反复IVF失败组较对照组有11种氨基酸含量显著升高,而二元羧酸、胆固醇及部分有机酸含量显著降低.结论:升高的缬氨酸、苏氨酸、异亮氨酸、半胱氨酸、丝氨酸、脯氨酸、丙氨酸、苯丙氨酸、赖氨酸、甲硫氨酸、鸟氨酸,和降低的二元羧酸、胆固醇可能成为预测卵子发育潜能的代谢标志物.%Objective: To explore the metabolomic profile which can access the oocyte developmental capacity. Methods: The follicular fluid (FF) samples were collected from 13 patients with repeated IVF failure (RIF) and 15 patients who got pregnant at the first IVF-ET theropy. Gas chromatography/mass spectrometry (GC-MS) was utilized to obtain the metabolomic information. Results: The PCA-DA scores showed that the different samples were scattered into two different regions, 20 metabolites were detected differently between the two groups. Conclusion: Elevated amino acid such as valine, threonine, isoleucine, cysteine, serine, proline, alanine, phenylalanine, lysine, methionine, ornithine and the decline of dual-carboxylic acid and cholesterol may predict the oocyte developmental capacity.

  4. 气相色谱-质谱法分析棕榈果脂肪酸组成%Analysis of Fatty Acid Composition in Oil Palm Fruit by Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    沈丹玉; 汤富彬; 钟冬莲; 倪张林; 屈明华; 莫润宏

    2012-01-01

    Palm oil and palm kernel oil were extracted by a soxhlet extractor, and esterfied with potassium hydroxide - methanol. The fatty acid compositions were determined by gas chromatography - mass spectrometry. Nine fatty acids were identified and quantified respectively. The relative content of saturated fatty acids from palm oil was 49.5 % , and existing forms were mainly palmitic acid and stearic acid. The unsaturated fatty acids were constituted of oleic acid, linoleic acid, linolenic acid and cis -13,16 - docosadienoic acid. The relative content of saturated fatty acids from palm kernel oil was more than 80, and lauric acid had the highest content obtained with content of 41.5% among them. The other main compositions were myristic acid, palmitic acid, hexanoic acid, octanoic acid, capric acid and stearic acid. Oleic acid and linoleic acid constituted the unsaturated fatty acids.%采用索氏抽提法分别提取棕榈果肉和棕榈果仁中的油脂,以氢氧化钾—甲醇溶液对油脂进行甲酯化处理,用气相色谱-质谱( GC-MS)法分析.从棕榈果肉和棕榈仁的油脂中均分离并鉴定了9种脂肪酸,其中棕榈果肉中饱和脂肪酸质量分数为49.5%,主要有棕榈酸和硬脂酸,不饱和脂肪酸主要有油酸、亚油酸以及少量的亚麻酸和13,16-二十二碳二烯酸.棕榈仁中饱和脂肪酸80%以上,其中月桂酸质量分数达到41.5%,肉豆蔻酸和棕榈酸含量也较高,此外还含有少量的己酸、辛酸、癸酸和硬脂酸,不饱和脂肪酸有油酸和亚油酸.

  5. Analysis of Volatile Compounds from Litsea cubeba Female Flower by Solid Phase Microextraction and Gas Chromatography Mass Spectrometry%山苍子雌花挥发性成分的 SPME -GC/MS 分析

    Institute of Scientific and Technical Information of China (English)

    陈萍; 王建刚

    2015-01-01

    The research aimed to analyze the chemical compounds in female flowers of Litsea cubeba and their relative content.Under optimized extraction conditions , headspace solid -phase micro extraction (HS -SPME) coupled with gas chromatography -mass spectrometry (GC -MS) was used to the extraction and determination of the volatile compounds in female flowers of Litsea cubeba.66 peaks were separated and 59 compounds were identified.The relative of each compound was determined, including alpha -Pinene (5.52 %),4(10) -Thujen(30.20%),beta -Pinene(4.95 %),alpha -Phellandrene(8.97 %),D -Limonene(8.56 %),Eucalyptol(10.05 %),alpha -Terpineol(5.41 %)etc.The study on the volatile compounds from female flowers of Litsea cubeba provided the test basis for the further development and utilization of Litsea cubeba resources .%采用顶空固相微萃取(HS -SPME)和气相色谱质谱联用(GC -MS)技术对山苍子雌花挥发性化学成分进行分离鉴定,用色谱峰面积归一化法确定各组分的相对含量。从山苍子雌花挥发性物质中分离出了66个组分,鉴定出了59个组分,并测定了各组分相对含量,包括α-蒎烯(5.52%),桧烯(30.20%),β-蒎烯(4.95%),α-水芹烯(8.97%),D -柠檬烯(8.56%),桉叶油醇(10.05%),α-松油醇(5.41%)等。通过对山苍子雌花挥发性成分的研究,为山苍子资源的进一步开发利用提供了参考依据。

  6. Exploration of the serum metabolite signature in patients with rheumatoid arthritis using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhou, Jia; Chen, Jiao; Hu, Changfeng; Xie, Zhijun; Li, Haichang; Wei, Shuangshuang; Wang, Dawei; Wen, Chengping; Xu, Guowang

    2016-08-01

    Rheumatoid arthritis (RA) is a systemic autoimmune disease with complicated pathogeny. There could be obvious alterations of metabolism in the patients with RA and the discovery of metabolic signature may be helpful for the accurate diagnosis of RA. In order to explore the distinctive metabolic patterns in RA patients, a gas chromatography-mass spectrometry (GC-MS) method was employed. Serum samples from 33 RA patients and 32 healthy controls were collected and analyzed. Acquired metabolic data were assessed by the principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA), and the data analysis results showed RA patients and healthy controls have very different metabolic profiles. Variable importance for project values (VIP) and Student's t-test were combined to screen the significant metabolic changes caused by RA. Serums from RA patients were featured by decreased levels of amino acids and glucose, increased levels of fatty acids and cholesterol, which were primarily associated with glycolytic pathway, fatty acid and amino acid metabolism, and other related pathways including TCA cycle and the urea cycle. These preliminary results suggest that GC-MS based metabolic profiling study appears to be a useful tool in the exploration of the metabolic signature of RA, and the revealed disease-associated metabolic perturbations could help to elucidate the pathogenesis of RA and provide a probable aid for the accurate diagnosis of RA. PMID:26879423

  7. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  8. Determination of Volatile Compounds in Four Commercial Samples of Japanese Green Algae Using Solid Phase Microextraction Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Masayoshi Yamamoto

    2014-01-01

    Full Text Available Green algae are of great economic importance. Seaweed is consumed fresh or as seasoning in Japan. The commercial value is determined by quality, color, and flavor and is also strongly influenced by the production area. Our research, based on solid phase microextraction gas chromatography mass spectrometry (SPME-GC-MS, has revealed that volatile compounds differ intensely in the four varieties of commercial green algae. Accordingly, 41 major volatile compounds were identified. Heptadecene was the most abundant compound from Okayama (Ulva prolifera, Tokushima (Ulva prolifera, and Ehime prefecture (Ulva linza. Apocarotenoids, such as ionones, and their derivatives were prominent volatiles in algae from Okayama (Ulva prolifera and Tokushima prefecture (Ulva prolifera. Volatile, short chained apocarotenoids are among the most potent flavor components and contribute to the flavor of fresh, processed algae, and algae-based products. Benzaldehyde was predominant in seaweed from Shizuoka prefecture (Monostroma nitidum. Multivariant statistical analysis (PCA enabled simple discrimination of the samples based on their volatile profiles. This work shows the potential of SPME-GC-MS coupled with multivariant analysis to discriminate between samples of different geographical and botanical origins and form the basis for development of authentication methods of green algae products, including seasonings.

  9. Different Analytical Procedures for the Study of Organic Residues in Archeological Ceramic Samples with the Use of Gas Chromatography-mass Spectrometry.

    Science.gov (United States)

    Kałużna-Czaplińska, Joanna; Rosiak, Angelina; Kwapińska, Marzena; Kwapiński, Witold

    2016-01-01

    The analysis of the composition of organic residues present in pottery is an important source of information for historians and archeologists. Chemical characterization of the materials provides information on diets, habits, technologies, and original use of the vessels. This review presents the problem of analytical studies of archeological materials with a special emphasis on organic residues. Current methods used in the determination of different organic compounds in archeological ceramics are presented. Particular attention is paid to the procedures of analysis of archeological ceramic samples used before gas chromatography-mass spectrometry. Advantages and disadvantages of different extraction methods and application of proper quality assurance/quality control procedures are discussed. PMID:25830900

  10. Comparison of gas chromatography/mass spectrometry and immunoassay techniques on concentrations of atrazine in storm runoff

    Science.gov (United States)

    Lydy, Michael J.; Carter, D.S.; Crawford, Charles G.

    1996-01-01

    Gas chromatography/mass spectrometry (GC/MS) and enzyme-linked immunosorbent assay (ELISA) techniques were used to measure concentrations of dissolved atrazine in 149 surface-water samples. Samples were collected during May 1992–September 1993 near the mouth of the White River (Indiana) and in two small tributaries of the river. GC/MS was performed on a Hewlett-Packard 5971 A, with electron impact ionization and selected ion monitoring of filtered water samples extracted by C-18 solid phase extraction; ELISA was performed with a magnetic-particle-based assay with photometric analysis. ELISA results compared reasonably well to GC/MS measurements at concentrations below the Maximum Contaminant Level for drinking water set by the U.S. Environmental Protection Agency (3.0 μg/L), but a systematic negative bias was observed at higher concentrations. When higher concentration samples were diluted into the linear range of calibration, the relation improved. A slight positive bias was seen in all of the ELISA data compared to the GC/MS results, and the bias could be partially explained by correcting the ELISA data for cross reactivity with other triazine herbicides. The highest concentrations of atrazine were found during the first major runoff event after the atrazine was applied. Concentrations decreased throughout the rest of the sampling period even though large runoff events occurred during this time, indicating that most atrazine loading to surface waters in the study area occurs within a few weeks after application.

  11. Rapid determination of polysaccharides in BianTi Soft extract by spectrophotometry coupled with gas chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Minxia Zheng

    2010-01-01

    Full Text Available A simple approach for the rapid determination of polysaccharides in BianTi Soft Extract using spectrophotometry coupled with gas chromatography-mass spectrometry (GC-MS was developed. The mixed standard solution composed of D-glucose, D-mannose, galactose and D-xylose in different proportions (1.00: 1.01: 0.12: 0.05 was prepared according to the monosaccharide composition analysis of the polysaccharides by GC-MS. The determination of polysaccharides by UV-Vis spectrophotometer was performed after 35-min color reaction, in which 1 ml 5% phenol and 4 ml sulfate was used. The assay of the method validation has shown that the method was stable, reliable and feasible. Furthermore, the proposed method was successfully applied in the preparation procedure of BianTi Soft Extract, selecting out optimal decoction conditions and suitable decoction container. It suggests that the convenient method could be useful for the quality control of BianTi Soft Extract. Meanwhile, it may be an alternative for polysaccharides determination of other formulations.

  12. Analytical Approaches Based on Gas Chromatography Mass Spectrometry (GC/MS) to Study Organic Materials in Artworks and Archaeological Objects.

    Science.gov (United States)

    Bonaduce, Ilaria; Ribechini, Erika; Modugno, Francesca; Colombini, Maria Perla

    2016-02-01

    Gas chromatography/mass spectrometry (GC/MS), after appropriate wet chemical sample pre-treatments or pyrolysis, is one of the most commonly adopted analytical techniques in the study of organic materials from cultural heritage objects. Organic materials in archaeological contexts, in classical art objects, or in modern and contemporary works of art may be the same or belong to the same classes, but can also vary considerably, often presenting different ageing pathways and chemical environments. This paper provides an overview of the literature published in the last 10 years on the research based on the use of GC/MS for the analysis of organic materials in artworks and archaeological objects. The latest progresses in advancing analytical approaches, characterising materials and understanding their degradation, and developing methods for monitoring their stability are discussed. Case studies from the literature are presented to examine how the choice of the working conditions and the analytical approaches is driven by the analytical and technical question to be answered, as well as the nature of the object from which the samples are collected. PMID:27572989

  13. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS. PMID:27566339

  14. Simultaneous determination of five anti-epilepsy drugs in human plasma using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    STEFANIE; WeiBig

    2010-01-01

    A new liquid chromatography-mass spectrometry method for the determination of carbamazepine,clonazepam,alprazolam,estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard.Chromatographic separation was performed on a Zorbax SB-C18 column(30 mm × 2.1 mm,3.5 ?m) with a mobile phase consisting of methanol and aqueous 25 mM ammonium acetate using gradient elution.A diethyl ether extraction method was used for the extraction of five anti-epilepsy drugs.The final extract was injected for analysis by LC-MS/MS.The method was validated within the concentration range of 50-5000 ng mL-1 for five anti-epilepsy drugs.The precision of the assay(RSD%) was less than 10% at all concentration levels within the tested range.The method recoveries for all samples were more than 90%.The results indicate that the method is specific,sensitive and accurate,and suitable to study the pharmacokinetics,to adjust the dosage for individual administration,and to monitor the drug-concentration and drug abuse of the five anti-epilepsy drugs.

  15. Determination of Panthenol, Cholecalciferol and Tocopherol in Cosmetic Products by Gas Chromatography-Mass Spectrometry in SIM Mode.

    Science.gov (United States)

    Jeong, H J; Lee, M H; Ro, K W; Hur, C W; Kim, J W

    1999-02-01

    A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry (GC-MS) has been developed. Three vitamins (panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran (ThF), and silylated with bis-trimethylsilyltri-fluoroacetamide- trichloromethylsilane (BSTFA). Silylated vitamins were separated on a fused-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring (SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50 pg of panthenol, 285 pg of cholecalciferol and 130 pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product (i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, convenient and exact determination of panthenol, cholecalciferol and tocopherol. PMID:18505529

  16. [Determination of short chain chlorinated paraffins in leather products by solid phase extraction coupled with gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun

    2014-10-01

    The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.

  17. Determination of dimethyl trisulfide in rabbit blood using stir bar sorptive extraction gas chromatography-mass spectrometry.

    Science.gov (United States)

    Manandhar, Erica; Maslamani, Nujud; Petrikovics, Ilona; Rockwood, Gary A; Logue, Brian A

    2016-08-26

    Cyanide poisoning by accidental or intentional exposure poses a severe health risk. The current Food and Drug Administration approved antidotes for cyanide poisoning can be effective, but each suffers from specific major limitations concerning large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. Dimethyl trisulfide (DMTS), a sulfur donor that detoxifies cyanide by converting it into thiocyanate (a relatively nontoxic cyanide metabolite), is a promising next generation cyanide antidote. Although a validated analytical method to analyze DMTS from any matrix is not currently available, one will be vital for the approval of DMTS as a therapeutic agent against cyanide poisoning. Hence, a stir bar sorptive extraction (SBSE) gas chromatography - mass spectrometry (GC-MS) method was developed and validated for the analysis of DMTS from rabbit whole blood. Following acid denaturation of blood, DMTS was extracted into a polydimethylsiloxane-coated stir bar. The DMTS was then thermally desorbed from the stir bar and analyzed by GC-MS. The limit of detection of DMTS using this method was 0.06μM with dynamic range from 0.5-100μM. For quality control standards, the precision, as measured by percent relative standard deviation, was below 10%, and the accuracy was within 15% of the nominal concentration. The method described here will allow further investigations of DMTS as a promising antidote for cyanide poisoning. PMID:27477518

  18. Direct detection of Mycobacterium tuberculosis in sputum: A validation study using solid phase extraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Mourão, Marta P B; Kuijper, Sjoukje; Dang, Ngoc A; Walters, Elisabetta; Janssen, Hans-Gerd; Kolk, Arend H J

    2016-02-15

    Tuberculosis (TB) remains a worldwide health problem, especially in developing countries. Correct identification of Mycobacterium tuberculosis (MTB) infection is extremely important for providing appropriate treatment and care to patients. Here we describe a solid phase extraction-gas chromatography-mass spectrometry method (SPE-THM-GC-MS) for the detection of five biomarkers for M. tuberculosis. The method for classification is developed and validated through the analysis of 112 sputum samples from patients suspected of having TB. Twenty of twenty-five MTB culture-positive sputum samples were correctly classified as positive by our improved SPE-THM-GC-MS method. Eighty-five of eighty-seven MTB culture-negative samples were also negative by SPE-THM-GC-MS. The overall sensitivity of the new SPE-THM-GC-MS method is 80% (20/25) and the specificity is 98% (85/87) compared with culture. The method proved to be reliable and, although complex in principle, easy to operate due to the high degree of automation. PMID:26807702

  19. Oligosaccharide substrate preferences of human extracellular sulfatase Sulf2 using liquid chromatography-mass spectrometry based glycomics approaches.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Sulfs are extracellular endosulfatases that selectively remove the 6-O-sulfate groups from cell surface heparan sulfate (HS chain. By altering the sulfation at these particular sites, Sulfs function to remodel HS chains. As a result of the remodeling activity, HSulf2 regulates a multitude of cell-signaling events that depend on interactions between proteins and HS. Previous efforts to characterize the substrate specificity of human Sulfs (HSulfs focused on the analysis of HS disaccharides and synthetic repeating units. In this study, we characterized the substrate preferences of human HSulf2 using HS oligosaccharides with various lengths and sulfation degrees from several naturally occurring HS sources by applying liquid chromatography mass spectrometry based glycomics methods. The results showed that HSulf2 preferentially digests highly sulfated HS oligosaccharides with zero acetyl groups and this preference is length dependent. In terms of length of oligosaccharides, HSulf2 digestion induced more sulfation decrease on DP6 (DP: degree of polymerization compared to DP2, DP4 and DP8. In addition, the HSulf2 preferentially digests the oligosaccharide domain located at the non-reducing end (NRE of the HS and heparin chain. In addition, the HSulf2 digestion products were altered only for specific isomers. HSulf2 treated NRE oligosaccharides also showed greater decrease in cell proliferation than those from internal domains of the HS chain. After further chromatographic separation, we identified the three most preferred unsaturated hexasaccharide for HSulf2.

  20. Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F

    2013-11-15

    This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. PMID:24148498

  1. Trace determination of the flame retardant tetrabromobisphenol A in the atmosphere by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xie Zhiyong [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany) and Johann Wolfgang Goethe-University Frankfurt at Main, Institute of Atmospheric and Environmental Sciences, Department of Analytical Environmental Chemistry, Georg-Voigt-Str. 14, 60054 Frankfurt (Germany)]. E-mail: zhiyong.xie@gkss.de; Ebinghaus, Ralf [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany); Lohmann, Rainer [Graduate School of Oceanography, University of Rhode Island, Narragansett, RI 02882-1197 (United States); Heemken, Olaf [LAVES, Philosophenweg 36/38, D-26121 Oldenburg (Germany); Caba, Armando [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany); Puettmann, Wilhelm [Johann Wolfgang Goethe-University Frankfurt at Main, Institute of Atmospheric and Environmental Sciences, Department of Analytical Environmental Chemistry, Georg-Voigt-Str. 14, 60054 Frankfurt (Germany)

    2007-02-19

    A simple and effective method has been developed for analysis of the flame retardant tetrabromobisphenol A (TBBPA) in environmental samples by using modified soxhlet extraction in combination with silica gel clean-up, derivatization with silylation reagent and gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring mode (SIM). Satisfactory recoveries were achieved for the large volume sampling, soxhlet extraction and silica gel clean-up. The overall recovery is 79 {+-} 1%. The derivatization procedure is simple and fast, and produces stable TBBPA derivative. GC-MS with electronic impact (EI) ionization mode shows better detection power than using negative chemical ionization (NCI) mode. EI gives a method detection limit of 0.04 pg m{sup -3} and enables to determine trace TBBPA in ambient air in remote area. The method was successfully applied to the determination of TBBPA in atmospheric samples collected over land and coastal regions. The concentrations of TBBPA ranged from below the method detection limit (0.04 pg m{sup -3}) to 0.85 pg m{sup -3}. A declining trend with increasing latitude was present from the Wadden Sea to the Arctic. The atmospheric occurrence of TBBPA in the Arctic is significant and might imply that TBBPA has long-range transport potential.

  2. Evaluation of dried blood spots as sample matrix for gas chromatography/mass spectrometry based metabolomic profiling.

    Science.gov (United States)

    Kong, Sing Teang; Lin, Hai-Shu; Ching, Jianhong; Ho, Paul C

    2011-06-01

    We propose using dried blood spots (DBS) as sample matrix for gas chromatography/mass spectrometry (GC/MS) based metabolomic profiling for the benefits of higher sample stability, more convenient sample acquisition with DBS, higher analyte separation power, and more readily biomarker identification with GC/MS. To establish this proposition, the metabolomic profiles generated from DBS were compared with that obtained from the conventional whole blood and plasma matrixes and also with dried plasma spots (DPS) as another covariate control. Our findings indicated that whole blood produced the most number of detectable markers (866), whereas DPS yielded the least number (614). DBS and plasma matrix, on the other hand, produced the most similar numbers of detectable (695 vs 749) and identifiable markers (137 vs 147, matching with Fiehn library). From the analysis of the DBS and plasma metabolomic profiles, it was concluded that when l-lysine 2, iminodiacetic acid 2, dl-threo-beta-hydroxyaspartic acid, citric acid, or adenosine-5-monophosphate 2 are not involved as markers, DBS could be a suitable substitute for plasma for metabolomic profiling.

  3. Metabolic Toxicity Screening Using Electrochemiluminescence Arrays Coupled with Enzyme-DNA Biocolloid Reactors and Liquid Chromatography-Mass Spectrometry

    Science.gov (United States)

    Hvastkovs, Eli, G.; Schenkman, John B.; Rusling, James, F.

    2012-07-01

    New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography-mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates.

  4. Analytical Approaches Based on Gas Chromatography Mass Spectrometry (GC/MS) to Study Organic Materials in Artworks and Archaeological Objects.

    Science.gov (United States)

    Bonaduce, Ilaria; Ribechini, Erika; Modugno, Francesca; Colombini, Maria Perla

    2016-02-01

    Gas chromatography/mass spectrometry (GC/MS), after appropriate wet chemical sample pre-treatments or pyrolysis, is one of the most commonly adopted analytical techniques in the study of organic materials from cultural heritage objects. Organic materials in archaeological contexts, in classical art objects, or in modern and contemporary works of art may be the same or belong to the same classes, but can also vary considerably, often presenting different ageing pathways and chemical environments. This paper provides an overview of the literature published in the last 10 years on the research based on the use of GC/MS for the analysis of organic materials in artworks and archaeological objects. The latest progresses in advancing analytical approaches, characterising materials and understanding their degradation, and developing methods for monitoring their stability are discussed. Case studies from the literature are presented to examine how the choice of the working conditions and the analytical approaches is driven by the analytical and technical question to be answered, as well as the nature of the object from which the samples are collected.

  5. Validation of biomarkers for distinguishing Mycobacterium tuberculosis from non-tuberculous mycobacteria using gas chromatography-mass spectrometry and chemometrics.

    Directory of Open Access Journals (Sweden)

    Ngoc A Dang

    Full Text Available Tuberculosis (TB remains a major international health problem. Rapid differentiation of Mycobacterium tuberculosis complex (MTB from non-tuberculous mycobacteria (NTM is critical for decisions regarding patient management and choice of therapeutic regimen. Recently we developed a 20-compound model to distinguish between MTB and NTM. It is based on thermally assisted hydrolysis and methylation gas chromatography-mass spectrometry and partial least square discriminant analysis. Here we report the validation of this model with two independent sample sets, one consisting of 39 MTB and 17 NTM isolates from the Netherlands, the other comprising 103 isolates (91 MTB and 12 NTM from Stellenbosch, Cape Town, South Africa. All the MTB strains in the 56 Dutch samples were correctly identified and the model had a sensitivity of 100% and a specificity of 94%. For the South African samples the model had a sensitivity of 88% and specificity of 100%. Based on our model, we have developed a new decision-tree that allows the differentiation of MTB from NTM with 100% accuracy. Encouraged by these findings we will proceed with the development of a simple, rapid, affordable, high-throughput test to identify MTB directly in sputum.

  6. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS.

  7. Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method

    Directory of Open Access Journals (Sweden)

    Simona Nicoara

    2009-01-01

    Full Text Available The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B, toluene (T, ethyl benzene (E, and o-, m-, p-xylenes (X. Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m3 (B, 13–90 μg/m3 (T, 7–50 μg/m3 (E, 10–70 μg/m3 (X-m,p, and 20–130 μg/m3 (X-o. The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m3 (Xo, 5/3 μg/m3 (B, E, X-m,p, and of 3/1 μg/m3 (T, respectively.

  8. Determination of organotin compounds in-water by headspace solid phase microextraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chou, Chi-Chi; Lee, Maw-Rong

    2005-01-28

    This investigation evaluates headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to determine trace levels of organotins in water. The organotins were derivatized in situ with sodium tetraethylborate and adsorbed on a poly(dimethysiloxane) (PDMS)-coated fused silica fiber. The SPME experimental procedures to extract organotins in water were at pH 5, with extraction and derivatization simultaneously at 45 degrees C for 30 min in a 2% sodium tetraethylborate solution and a sample solution volume in the ratio of 1:1, and desorption in the splitless injection port of the GC at 260 degrees C for 2 min. Detection limits are determined to be in the low ng/L range. According to the analysis, the linearity range is from 10 to 10,000 ng/L with R.S.D. values below 12% except triphenyltin (24%). The proposed method was tested by analyzing surface seawater from the harbors on the Taiwanese coast for organotins residues. Some organotins studied were detected in the analyzed samples. Results of this study demonstrate the adequacy of the headspace SPME-GC-MS method for analyzing organotins in sea water samples. PMID:15729814

  9. Speciation of butyltin compounds in marine sediments with headspace solid phase microextraction and gas chromatography - mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cardellicchio, N.; Giandomenico, S.; Decataldo, A.; Di Leo, A. [CNR - Istituto Sperimentale Talassografico, Taranto (Italy)

    2001-03-01

    A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry.The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown. (orig.)

  10. Speciation of butyltin compounds in marine sediments with headspace solid phase microextraction and gas chromatography mass spectrometry.

    Science.gov (United States)

    Cardellicchio, N; Giandomenico, S; Decataldo, A; Di Leo, A

    2001-03-01

    A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown. PMID:11336336

  11. 分子蒸馏技术拆分独活油及GC-MS分析%Gas chromatography/Mass Spectrometry (GC-MS) Analysis of the Essential Oil from Angelica Pubescens Maxim. by Molecular Distillation Separation

    Institute of Scientific and Technical Information of China (English)

    侯召华; 邹飞雪

    2015-01-01

    The essential oil was extracted from Angelica pubescens Maxim. by steam distillation and fractionated by molecular distillation ( MD ) . The crude essential oil was used as the feed for two molecular distillation processes. One residue ( RF2 ) and two distillate ( DF1 and DF2 ) fractions were prepared by MD. Three fractions were obtained under the operation parameters of 30 ℃,5. 0mbar;and 60℃, 5. 0mbar, respectively. The chemical components of different fractions were analyzed by Gas chromatography/mass spectrometry ( GC-MS) . Results:The yields of distilled fractions ( DF1 ,and DF2 ) and residued fractions (RF2)were 33. 65%,61. 39%,and 3. 88% (w/w),respectively. GC-MS results revealed that 21 ingredients were detected in the essential oil, including (+)-Limonene,α-Pinene,β-Pinene, Terpinen-4-ol, Eucalyptol, Terpinolene, and (-)-Carveol et. Concentrations and compositions of chemical components in different factions were significantly different. In conclusion, the technology of molecular distillation is a feasible separaction method for essential oil.%独活原油由水蒸汽蒸馏法得到,经过分子蒸馏拆分,得到不同馏分,进行气相色谱-质谱( GC-MS)分析。分子蒸馏为二级,一级条件:蒸发温度30℃、真空度500 Pa、刮膜转速150 r/min;二级条件:蒸发温度60℃、真空度500 Pa、刮膜转速200 r/min;两级进样温度30℃、冷凝水温度10℃。两级分子蒸馏共得到3部分,总上样量336.17 g,回收得到332.51 g,回收率98.92%;一级轻组分(DF1)113.12 g(33.65%);二级轻组分(DF2)206.36 g (61.39%);二级重组分(RF2)13.03 g,所占质量比3.88%。原油和馏分物中共确定21种化合物,主要是右旋萜二烯、α-蒎烯、4-异丙基甲苯、萜品烯、月桂烯等;三部分馏分物( DF1,DF2和RF2)和原油中组分数量分别为8、10、17和6种;且不同组分中成分数量及浓度差异显著。分子蒸馏是一种有效的分离纯化技术,可应用于挥发油的加工利用。

  12. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  13. Systematic analysis of glycerol: colourimetric screening and gas chromatography-mass spectrometric confirmation.

    Science.gov (United States)

    Sardela, Vinícius F; Scalco, Fernanda B; Cavalcante, Karina M; Simoni, Ruth E; Silva, Deyvison R; Pereira, Henrique Marcelo G; de Oliveira, Maria Lúcia L Costa; Aquino Neto, Francisco R

    2015-10-01

    Glycerol is a naturally occurring polyol in the human body, essential for several metabolic processes. It is widely used in the food, pharmaceutical, and medical industries and in clinical practice as a plasma volume expander (PVE). Athletes, however, may use glycerol to mask the presence of forbidden substances or to enhance performance, inclusively through hyperhydration achieved by glycerol ingestion with added fluid. These practices are considered doping, and are prohibited by the World Anti-Doping Agency (WADA). Therefore, glycerol was introduced in the prohibited list. Doping through glycerol ingestion can readily be identified by detection of elevated glycerol concentrations in urine. In this paper, a protocol for the fast detection of glycerol in urine is proposed. It consists of a previous visual colourimetric screening, followed by a quantitative/qualitative confirmation analysis by mass spectrometry. The screening procedure involves a reaction in which polyhydric alcohols are oxidized by periodate to formic acid and formaldehyde, which is detected by the addition of a fuchsin solution. For the subsequent qualitative/quantitative confirmation analysis, a gas chromatography-mass spectrometry based approach with a non-deuterated internal standard and a drying step of only 10 min is proposed. The linear correlation was demonstrated within WADA´s threshold range. The calculated RSD were 2.1% for within-day precision and 2.8% for between-day precision. The uncertainty estimation was calculated, and a value of 2.7% was obtained. The procedure may also be used for the analysis of other polyols in urine, as for example the PVE mannitol. PMID:26112364

  14. Systematic analysis of glycerol: colourimetric screening and gas chromatography-mass spectrometric confirmation.

    Science.gov (United States)

    Sardela, Vinícius F; Scalco, Fernanda B; Cavalcante, Karina M; Simoni, Ruth E; Silva, Deyvison R; Pereira, Henrique Marcelo G; de Oliveira, Maria Lúcia L Costa; Aquino Neto, Francisco R

    2015-10-01

    Glycerol is a naturally occurring polyol in the human body, essential for several metabolic processes. It is widely used in the food, pharmaceutical, and medical industries and in clinical practice as a plasma volume expander (PVE). Athletes, however, may use glycerol to mask the presence of forbidden substances or to enhance performance, inclusively through hyperhydration achieved by glycerol ingestion with added fluid. These practices are considered doping, and are prohibited by the World Anti-Doping Agency (WADA). Therefore, glycerol was introduced in the prohibited list. Doping through glycerol ingestion can readily be identified by detection of elevated glycerol concentrations in urine. In this paper, a protocol for the fast detection of glycerol in urine is proposed. It consists of a previous visual colourimetric screening, followed by a quantitative/qualitative confirmation analysis by mass spectrometry. The screening procedure involves a reaction in which polyhydric alcohols are oxidized by periodate to formic acid and formaldehyde, which is detected by the addition of a fuchsin solution. For the subsequent qualitative/quantitative confirmation analysis, a gas chromatography-mass spectrometry based approach with a non-deuterated internal standard and a drying step of only 10 min is proposed. The linear correlation was demonstrated within WADA´s threshold range. The calculated RSD were 2.1% for within-day precision and 2.8% for between-day precision. The uncertainty estimation was calculated, and a value of 2.7% was obtained. The procedure may also be used for the analysis of other polyols in urine, as for example the PVE mannitol.

  15. [Progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes].

    Science.gov (United States)

    Wang, Huanhuan; Lu, Yayao; Peng, Bo; Qian, Xiaohong; Zhang, Yangjun

    2015-06-01

    Cytochrome P450 (CYP) enzymes and uridine 5-diphospho-glucuronosyltransferase (UGT) enzymes are critical enzymes for drug metabolism. Both chemical drugs and traditional Chinese medicines are converted to more readily excreted compounds by drug metabolizing enzymes in human livers. Because of the disparate expression of CYP and UGT enzymes among different individuals, accurate quantification of these enzymes is essential for drug pharmacology, drug-drug interactions and drug clinical applications. The research progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes in the recent decade is reviewed.

  16. Application of capillary gas chromatography mass spectrometry/computer techniques to synoptic survey of organic material in bed sediment

    Science.gov (United States)

    Steinheimer, T.R.; Pereira, W.E.; Johnson, S.M.

    1981-01-01

    A bed sediment sample taken from an area impacted by heavy industrial activity was analyzed for organic compounds of environmental significance. Extraction was effected on a Soxhlet apparatus using a freeze-dried sample. The Soxhlet extract was fractionated by silica gel micro-column adsorption chromatography. Separation and identification of the organic compounds was accomplished by capillary gas chromatography/mass spectrometry techniques. More than 50 compounds were identified; these include saturated hydrocarbons, olefins, aromatic hydrocarbons, alkylated polycyclic aromatic hydrocarbons, and oxygenated compounds such as aldehydes and ketones. The role of bed sediments as a source or sink for organic pollutants is discussed. ?? 1981.

  17. Development of a Rapid Microbore Metabolic Profiling Ultraperformance Liquid Chromatography-Mass Spectrometry Approach for High-Throughput Phenotyping Studies.

    Science.gov (United States)

    Gray, Nicola; Adesina-Georgiadis, Kyrillos; Chekmeneva, Elena; Plumb, Robert S; Wilson, Ian D; Nicholson, Jeremy K

    2016-06-01

    A rapid gradient microbore ultraperformance liquid chromatography-mass spectrometry (UPLC-MS) method has been developed to provide a high-throughput analytical platform for the metabolic phenotyping of urine from large sample cohorts. The rapid microbore metabolic profiling (RAMMP) approach was based on scaling a conventional reversed-phase UPLC-MS method for urinary profiling from 2.1 mm × 100 mm columns to 1 mm × 50 mm columns, increasing the linear velocity of the solvent, and decreasing the gradient time to provide an analysis time of 2.5 min/sample. Comparison showed that conventional UPLC-MS and rapid gradient approaches provided peak capacities of 150 and 50, respectively, with the conventional method detecting approximately 19 000 features compared to the ∼6 000 found using the rapid gradient method. Similar levels of repeatability were seen for both methods. Despite the reduced peak capacity and the reduction in ions detected, the RAMMP method was able to achieve similar levels of group discrimination as conventional UPLC-MS when applied to rat urine samples obtained from investigative studies on the effects of acute 2-bromophenol and chronic acetaminophen administration. When compared to a direct infusion MS method of similar analysis time the RAMMP method provided superior selectivity. The RAMMP approach provides a robust and sensitive method that is well suited to high-throughput metabonomic analysis of complex mixtures such as urine combined with a 5-fold reduction in analysis time compared with the conventional UPLC-MS method. PMID:27116471

  18. Simultaneous Determination of Hexoestrol, Diethylstilbestrol, Estrone and 17-Beta-estradiol in Feed by Gas Chromatography-mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Huo Feng; Li Ning; Lin Xiao-Li

    2016-01-01

    A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatography-mass spectrometry. The results showed that the linear detectable ranged from 2.5 ng•mL-1 to 250 ng•mL-1 for hexoestrol and from 5 ng•mL-1 to 500 ng•mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug•kg-1 and 20 ug•kg-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples.

  19. Potential of needle trap microextraction-portable gas chromatography-mass spectrometry for measurement of atmospheric volatile compounds

    Science.gov (United States)

    Feijó Barreira, Luís Miguel; Xue, Yu; Duporté, Geoffroy; Parshintsev, Jevgeni; Hartonen, Kari; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2016-08-01

    Volatile organic compounds (VOCs) play a key role in atmospheric chemistry and physics. They participate in photochemical reactions in the atmosphere, which have direct implications on climate through, e.g. aerosol particle formation. Forests are important sources of VOCs, and the limited resources and infrastructures often found in many remote environments call for the development of portable devices. In this research, the potential of needle trap microextraction and portable gas chromatography-mass spectrometry for the study of VOCs at forest site was evaluated. Measurements were performed in summer and autumn 2014 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. During the first part of the campaign (summer) the applicability of the developed method was tested for the determination of monoterpenes, pinonaldehyde, aldehydes, amines and anthropogenic compounds. The temporal variation of aerosol precursors was determined, and evaluated against temperature and aerosol number concentration data. The most abundant monoterpenes, pinonaldehyde and aldehydes were successfully measured, their relative amounts being lower during days when particle number concentration was higher. Ethylbenzene, p- and m-xylene were also found when wind direction was from cities with substantial anthropogenic activity. An accumulation of VOCs in the snow cover was observed in the autumn campaign. Results demonstrated the successful applicability of needle trap microextraction and portable gas chromatography-mass spectrometry for the rapid in situ determination of organic gaseous compounds in the atmosphere.

  20. High-performance liquid chromatography-mass spectrometry for mapping and sequencing glycosaminoglycan-derived oligosaccharides

    OpenAIRE

    Volpi, Nicola; Linhardt, Robert J.

    2010-01-01

    Glycosaminoglycans (GAGs) have proven to be very difficult to analyze and characterize because of their high negative charge density, polydispersity and sequence heterogeneity. As the specificity of the interactions between GAGs and proteins results from the structure of these polysaccharides, an understanding of GAG structure is essential for developing a structure–activity relationship. Electrospray ionization (ESI) mass spectrometry (MS) is particularly promising for the analysis of oligos...

  1. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  2. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. PMID:26585206

  3. Determination of capsaicin, dihydrocapsaicin, and nonivamide in self-defense weapons by liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Reilly, C A; Crouc, D J; Yost, G S; Fatah, A A

    2001-04-01

    Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the analysis of capsaicin, dihydrocapsaicin, and nonivamide in pepper spray products have been developed. Chromatographic separation of the capsaicinoid analogues was achieved using a reversed-phase HPLC column and a stepwise gradient of methanol and distilled water containing 0.1% (v/v) formic acid. Identification and quantification of the capsaicinoids was achieved by electrospray ionization single-stage mass spectrometry monitoring the protonated molecules of the internal standard (m/z 280), capsaicin (m/z 306), dihydrocapsaicin (m/z 308), and nonivamide (m/z 294) or by tandem mass spectrometry monitoring the appropriate precursor-to-product-ion transitions. The plot of concentration versus peak area ratio was linear over the range of 10-750 ng/ml using LC-MS and 10-500 ng/ml using LC-MS-MS. However, to accurately quantify the capsaicinoids in the pepper spray products calibration curves between 10 and 1000 ng were constructed and fit using a weighted quadratic equation. Using the quadratic curve, the accuracy of the assay ranged from 91 to 102% for all analytes. The intra-assay precision (RSD) for capsaicin was 2% at 25 ng/ml, 10% at 500 ng/ml, and 3% at 800 ng/ml. The inter-assay precision (RSD) for capsaicin was 6% at 25 ng/ml, 6% at 500 ng/ml, and 9% at 800 ng/ml. Similar values for inter- and intra-assay precision were experimentally obtained for both dihydrocapsaicin and nonivamide. The analysis of selected pepper spray products demonstrated that the capsaicinoid concentration in the products ranged from 0.7 to 40.5 microg/microl. PMID:11330795

  4. Assessment of the degradation of polyurethane foams after artificial and natural ageing by using pyrolysis-gas chromatography/mass spectrometry and headspace-solid phase microextraction-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Lattuati-Derieux, A; Thao-Heu, S; Lavédrine, B

    2011-07-15

    Polyurethane foams are widely present in museum collections either as part of the artefacts, or as a material for their conservation. Unfortunately many of PU foam artefacts are in poor condition and often exhibit specific conservation issues. Their fast thermal and photochemical degradations have been the aim of previous researches. It is now accepted that hydrolysis predominates for polyester-based polyurethane PU(ES) whereas oxidation is the principal cause of degradation for polyether-based polyurethane PU(ET) variety. Only a few studies have been devoted to volatile organic compounds (VOCs) emitted by polyurethanes and, to our knowledge, none were performed on polyurethane foams by using headspace-solid phase microextraction (HS-SPME). The objective of the work described here is to assess the impact of some environmental factors (humidity, temperature and daylight) on the degradation of PU foams by evaluating their volatile fractions. We investigated morphological changes, polymerized fractions and volatile fractions of (i) one modern produced PU(ES) foam and one modern PU(ET) foam artificially aged in different conditions as well as (ii) four naturally aged foams collected from various daily life objects and selected for the representativeness of their analytical data. Characterization procedure used was based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) and non-invasive headspace solid-phase microextraction coupled with gas chromatography and mass spectrometry (HS-SPME-GC/MS). In this paper, the formation of alcohol and acid raw products for PU(ES) and glycol derivatives for PU(ET) during natural and artificial ageing is confirmed. These main products can be considered as degradation markers for PU foams. Results show that artificial and natural ageing provide similar analytical results, and confirm that the dominant degradation paths for PU(ES) and for PU(ET) are

  5. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg-1, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  6. Application of Pyrolysis Gas Chromatography/Mass Spectrometry in Lacquer Research: A Review

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Ma

    2014-01-01

    Full Text Available Examination of thermal degradation of natural and synthetic lacquer films by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS is reviewed. Due to the instantaneous heating decomposition, side reactions of internal or intermediate samples hardly occur, and the pyrolysis products can be retrieved without any change. Py-GC/MS has been used to analyze the composition of insoluble polymers and investigate degradation of resin materials. Lacquer film is a cross-linked polymer that is insoluble in any solvent. The aim of this review is to describe the application of Py-GC/MS to the analysis of lacquer, including natural lacquer saps, synthetic lacquer derivatives, and their films. After analyzing the chemical structures of the specific pyrolysis products by mass spectrometry, the lacquer tree species and growing region can be determined. These results have great significance for the protection and restoration of lacquer-coated cultural treasures.

  7. Analysis of Organic Molecules Extracted from Mars Analogues and Influence of Their Mineralogy Using N-Methyl-N-(tert-butyldimethylsilyl)Trifluoroacetamide Derivatization Coupled with Gas Chromatography Mass Spectrometry in Preparation for the Sample Analysis at Mars Derivatization Experiment on the Mars Science Laboratory Mission

    Science.gov (United States)

    Stalport, F.; Glavin, D. P.; Eigenbrode, J. L.; Bish, D.; Blake, D.; Coll, P.; Szopa, C.; Buch, A.; McAdam, A.; Dworkin, J. P.; Mahaffy, P. R.

    2012-01-01

    The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids will require a chemical extraction and derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed, a one-pot extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment on the Mars Science Laboratory (MSL). The temperature and duration the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 C for several minutes of a variety of terrestrial Mars analogue materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analogue materials that contained high abundances of hydrated minerals and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA, The combination of pyrolysis and two different chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars,

  8. The off-line combination of high performance liquid chromatography and comprehensive two-dimensional gas chromatography-mass spectrometry: a powerful approach for highly detailed essential oil analysis.

    Science.gov (United States)

    Tranchida, Peter Q; Zoccali, Mariosimone; Bonaccorsi, Ivana; Dugo, Paola; Mondello, Luigi; Dugo, Giovanni

    2013-08-30

    The present contribution is focused on the off-line combination of high performance liquid chromatography (HPLC) and comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC×GC-quadMS), and its application to the detailed qualitative analysis of essential oils. Specifically, a silica column was exploited for the separation of the essential oil constituents in two groups, namely hydrocarbon and oxygenated compounds. After, each HPLC-fraction was reduced in volume, and then subjected to cryogenically modulated GC×GC-quadMS analysis. The volatiles were separated on a normal-phase GC×GC column set, and identified through database matching and linear retention index information. The concentrated HPLC fractions gave origin to unexpectably crowded chromatograms, due to two fundamental GC×GC characteristics, namely the enhanced separation power and sensitivity. The results attained were particularly stimulating with regards to the oxygenated compounds, namely those constituents which contribute most to the essential oil aroma, and are of more use for the evaluation of quality and genuineness. Two genuine Citrus essential oils, bergamot and sweet orange, were subjected to analysis, and compared to applications carried out with a GC-quadMS instrument. PMID:23890548

  9. Rapid Preconcentration for Liquid Chromatography-Mass Spectrometry Assay of Trace Level Neuropeptides

    Science.gov (United States)

    Zhou, Ying; Mabrouk, Omar S.; Kennedy, Robert T.

    2013-11-01

    Measurement of neuropeptides in the brain through in vivo microdialysis sampling provides direct correlation between neuropeptide concentration and brain function. Capillary liquid chromatography-multistage mass spectrometry (CLC-MSn) has proven to be effective at measuring endogenous neuropeptides in microdialysis samples. In the method, microliter samples are concentrated onto nanoliter volume packed beds before ionization and mass spectrometry analysis. The long times required for extensive preconcentration present a barrier to routine use because of the many samples that must be analyzed and instability of neuropeptides. In this study, we evaluated the capacity of 75 μm inner diameter (i.d.) capillary column packed with 10 μm reversed phase particles for increasing the throughput in CLC-MSn based neuropeptide measurement. Coupling a high injection flow rate for fast sample loading/desalting with a low elution flow rate to maintain detection sensitivity, this column has reduced analysis time from ˜30 min to 3.8 min for 5 μL sample, with 3 pM limit of detection (LOD) for enkephalins and 10 pM LOD for dynorphin A1-8 in 5 μL sample. The use of isotope-labeled internal standard lowered peptide signal variation to less than 5 %. This method was validated for in vivo detection of Leu and Met enkephalin with microdialysate collected from rat globus pallidus. The improvement in speed and stability makes CLC-MSn measurement of neuropeptides in vivo more practical.

  10. Analysis of the chemical composition of the essential oils extracted from Lippia lacunosa Mart. and Schauer and Lippia rotundifolia Cham. (Verbenaceae) by gas chromatography and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Suzana G.; Barbosa, Ymira Galico [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Fac. de Farmacia; Oliveira, Danilo R. de; Leitao, Gilda G. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Nucleo de Pesquisas de Produtos Naturais]. E-mail: sgleitao@pharma.ufrj.br; Suelsen, Valeria; Martino, Virginia [Universidad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica; Bizzo, Humberto R.; Lopes, Daise [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil); Viccini, Lyderson F.; Salimena, Fatima R.G.; Peixoto, Paulo H.P. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Inst. de Ciencias Biolgicas

    2008-07-01

    Lippia lacunosa and L. rotundifolia (Verbenaceae) are two Brazilian species of complex taxonomic delimitation. The composition of the essential oils from leaves and flowers of these plants was investigated by gas chromatography (GC) and gas chromatography coupled with mass spectrometry (GC-MS) analysis. The major components of the essential oils of flowers and leaves of L. lacunosa were: myrcene (14.7% and 11.9%), myrcenone (45.2% and 64.2%), Z-ocimenone (5.7% and 5.2%), and E-ocimenone (14.7% and 4.1%), respectively; whereas in L. rotundifolia (flowers and leaves) were ..-pinene (8.7% and 1.8%), myrcene (5.1% and 3.6%), limonene (26.0% and 7.9 %), cis-pinocamphone (4.5% and 3.1%) and myrtenal (22.3% and 16.7%), respectively. The essential oils from L. lacunosa exhibited a strong and pleasant mango aroma, which was related to the presence of myrcene and myrcenone. The marked differences in the chemical composition of their essential oils may represent a powerful tool for the botanical classification. (author)

  11. Analysis of the chemical composition of the essential oils extracted from Lippia lacunosa Mart. and Schauer and Lippia rotundifolia Cham. (Verbenaceae) by gas chromatography and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Lippia lacunosa and L. rotundifolia (Verbenaceae) are two Brazilian species of complex taxonomic delimitation. The composition of the essential oils from leaves and flowers of these plants was investigated by gas chromatography (GC) and gas chromatography coupled with mass spectrometry (GC-MS) analysis. The major components of the essential oils of flowers and leaves of L. lacunosa were: myrcene (14.7% and 11.9%), myrcenone (45.2% and 64.2%), Z-ocimenone (5.7% and 5.2%), and E-ocimenone (14.7% and 4.1%), respectively; whereas in L. rotundifolia (flowers and leaves) were ..-pinene (8.7% and 1.8%), myrcene (5.1% and 3.6%), limonene (26.0% and 7.9 %), cis-pinocamphone (4.5% and 3.1%) and myrtenal (22.3% and 16.7%), respectively. The essential oils from L. lacunosa exhibited a strong and pleasant mango aroma, which was related to the presence of myrcene and myrcenone. The marked differences in the chemical composition of their essential oils may represent a powerful tool for the botanical classification. (author)

  12. Application of Gas Chromatography-mass Spectrometry in Analyzing Pharmacokinetics and Distribution of Deltamethrin in Miniature Pig Tissues

    Institute of Scientific and Technical Information of China (English)

    ZHU Pan; FAN Sai; ZOU Jian Hong; MIAO Hong; LI Jing Guang; ZHANG Guo Wen; WU Yong Ning

    2014-01-01

    Objective To characterize the pharmacokinetics and distribution profiles of deltamethrin in miniature pig tissues by gas chromatography-mass spectrometry (GC-MS). Methods Pharmacokinetics and distribution of deltamethrin in blood and tissues of 30 miniature pigs were studied by GC-MS after oral administration of deltamethrin (5 mg/kg bw). Data were processed by 3P97 software. Results The serum deltamethrin level was significantly lower in tissues than in blood of miniature pigs. The AUC0-72 h, Cmax, of deltamethrin were 555.330±316.987 ng h/mL and 17.861±11.129 ng/mL, respectively. The Tmax, of deltamethrin was 6.004±3.131 h. Conclusion The metabolism of deltamethrin in miniature pigs is fit for a one-compartment model with a weighting function of 1/C2. Deltamethrin is rapidly hydrolyzed and accumulated in miniature pig tissues.

  13. Hydrocarbon gases emitted from vehicles on the road. 1. A qualitative gas chromatography/mass spectrometry survey

    Energy Technology Data Exchange (ETDEWEB)

    Hampton, C.V.; Pierson, W.R.; Harvey, T.M.; Updegrove, W.S.; Marano, R.S.

    1982-05-01

    The gas-phase hydrocarbons greater than or equal to C/sub 5/ generated by motor vehicles in highway operation were surveyed in the Allegheny Mountain Tunnel of the Pennsylvania Turnpike in 1979. The samples were collected on Tenax GC polymer adsorbent and analyzed by glass-capillary gas chromatography/mass spectrometry. Approximately 400 vehicle-generated compounds were detected. Of these, over 300 were either completely or partially identified. In the various tunnel samples the same peaks are always present, with relative intensities varying according to the traffic composition. The compounds identified fall largely into homolgous series of normal and branched alkanes, alkenes, and various alkyl series based on cyclopentane, cyclohexane, benzene, styrene, indan, naphthalene, and decalin. Compounds not associated with homolgous series include indene, divinylbenzene, phenylacetylene, benzaldehyde, phenol, and a few halocarbons. Results from a preliminary experiment in 1977 at the Tuscarora Mountain Tunnell are also reported.

  14. Coal liquefaction process streams characterization and evaluation. Characterization of coal-derived materials by field desorption mass spectrometry, two-dimensional nuclear magnetic resonance, supercritical fluid extraction, and supercritical fluid chromatography/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Linehan, J.C.; Robins, W.H. [Battelle Pacific Northwest Lab., Richland, WA (United States)

    1992-07-01

    Under contract from the DOE , and in association with CONSOL Inc., Battelle, Pacific Northwest Laboratory (PNL) evaluated four principal and several complementary techniques for the analysis of non-distillable direct coal liquefaction materials in support of process development. Field desorption mass spectrometry (FDMS) and nuclear magnetic resonance (NMR) spectroscopic methods were examined for potential usefulness as techniques to elucidate the chemical structure of residual (nondistillable) direct coal liquefaction derived materials. Supercritical fluid extraction (SFE) and supercritical fluid chromatography/mass spectrometry (SFC/MS) were evaluated for effectiveness in compound-class separation and identification of residual materials. Liquid chromatography (including microcolumn) separation techniques, gas chromatography/mass spectrometry (GC/MS), mass spectrometry/mass spectrometry (MS/MS), and GC/Fourier transform infrared (FTIR) spectroscopy methods were applied to supercritical fluid extracts. The full report authored by the PNL researchers is presented here. The following assessment briefly highlights the major findings of the project, and evaluates the potential of the methods for application to coal liquefaction materials. These results will be incorporated by CONSOL into a general overview of the application of novel analytical techniques to coal-derived materials at the conclusion of CONSOL`s contract.

  15. Extraction and gas chromatography-mass spectrometry analysis of basella rubra seed oil%落葵籽油的提取及其气相色谱质谱联用分析

    Institute of Scientific and Technical Information of China (English)

    赵建芬; 梁巧荣; 佘银荣

    2012-01-01

    Basella rubra seed oil was extracted through organic solvent extraction(SE),microwave-assisted circum rotation reflux extraction(ME) and ultrasonic extraction(UE) and then analyzed by gas chromatography- mass spectrometry(GC-MS). The result showed that the yield of basella rubra seed oil extracted by ME was 15.06%,close to that by UE(15.09%) and higher than that by SE(9.20%).There were 14 components in basella rubra seed oil made by SE, 11 components by ME and 21 components by UE,and 11 components were the same. The relative contents of fatty acids in basella rubra seed oil were more that 85% ,saturated fatty acids were 25%, unsaturated fatty acids were more that 60%. Main components of fatty acids were oleic acid(31%), linoleic acid(23%) and palmitic acid(18%).%采用有机溶剂浸提(SE)、微波辅助旋转回流提取(ME)和超声波提取(UE)三种方法提取落葵籽油并进行气相色谱质谱联用(GC-MS)分析。结果表明,ME法和UE法的提取率十分接近,分别为15.06%、15.09%,均高于SE法的提取率9.20%;经GC-MS分离鉴定,SE法、ME法和UE法提取的落葵籽油分别有14、11、21种成分,其中共有成分为11种;脂肪酸相对含量占总含量85%以上,其中饱和脂肪酸相对含量占总含量25%以上,主要成分为棕榈酸(18%),不饱和脂肪酸相对含量占总含量60%以上,主要成分为油酸(31%)和亚油酸(23%)。

  16. An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kim Seongho

    2011-10-01

    Full Text Available Abstract Background Mass spectrometry (MS based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS. Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. Results With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. Conclusions We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http

  17. Development and validation of a solid-phase extraction method using anion exchange sorbent for the analysis of cannabinoids in plasma and serum by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga; Schürenkamp, Jennifer

    2016-07-01

    The aim of this work was to develop and validate a solid-phase extraction (SPE) method for the analysis of cannabinoids with emphasis on a very extensive and effective matrix reduction in order to ensure constant good results in selectivity and sensitivity regardless of the applied measuring technology. This was obtained by the use of an anion exchange sorbent (AXS) and the purposive ionic interaction between matrix components and this sorbent material. In a first step, the neutral cannabinoids ∆9-tetrahydrocannabinol (THC) and 11-hydroxy-∆9-tetrahydrocannabinol (11-OH-THC) were eluted, leaving 11-nor-9-carboxy-∆9-tetrahydrocannabinol (THC-COOH) and the main interfering matrix components bound to the AXS. In a second step, exploiting differences in pH and polarity, it was possible to separate matrix components and THC-COOH, thereby yielding a clean elution of THC-COOH into the same collecting tube as THC and 11-OH-THC. Even when using a simple measuring technology like gas chromatography with single quadrupole mass spectrometry, this two-step elution allows for an obvious decrease in number and intensity of matrix interference in the chromatogram. Hence, in both plasma and serum, the AXS extracts resulted in very good selectivity. Limits of detection and limits of quantification were below 0.25 and 0.35 ng/mL for the neutral cannabinoids in both matrices, 2.0 and 3.0 ng/mL in plasma and 1.6 and 3.3 ng/mL in serum for THC-COOH. The recoveries were ≥79.8 % for all analytes. Interday and intraday imprecisions ranged from 0.8 to 6.1 % relative standard deviation, and accuracy bias ranged from -12.6 to 3.6 %.

  18. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  19. Gas chromatography-mass spectrometry of ethyl palmitate calibration and resolution with ethyl oleate as biomarker ethanol sub acute in urine application study

    Science.gov (United States)

    Suaniti, Ni Made; Manurung, Manuntun

    2016-03-01

    Gas Chromatography-Mass Spectrometry is used to separate two and more compounds and identify fragment ion specific of biomarker ethanol such as palmitic acid ethyl ester (PAEE), as one of the fatty acid ethyl esters as early detection through conyugated reaction. This study aims to calibrate ethyl palmitate and develop analysis with oleate acid. This methode can be used analysis ethanol and its chemistry biomarker in ethanol sub-acute consumption as analytical forensic toxicology. The result show that ethanol level in urine rats Wistar were 9.21 and decreased 6.59 ppm after 48 hours consumption. Calibration curve of ethyl palmitate was y = 0.2035 x + 1.0465 and R2 = 0.9886. Resolution between ethyl palmitate and oleate were >1.5 as good separation with fragment ion specific was 88 and the retention time was 18 minutes.

  20. Characterization of odor-active compounds of various Chrysanthemum essential oils by gas chromatography-olfactometry, gas chromatography-mass spectrometry and their correlation with sensory attributes.

    Science.gov (United States)

    Xiao, Zuobing; Fan, Binbin; Niu, Yunwei; Wu, Minling; Liu, Junhua; Ma, Shengtao

    2016-01-15

    Volatiles of five kinds of Chrysanthemum essential oils with different manufactures were characterized by descriptive sensory analysis, gas chromatography-olfactometry (GC-O), gas chromatography-mass spectrometry (GC-MS) and statistics analysis. Six sensory attributes (floral, woody, grassy, fruity, sour and minty) were selected to assess Chrysanthemum essential oils. A total of 38 volatile compounds were detected and quantified using standard substances by GC-O and GC-MS. Terpenes constituted the largest chemical group among the volatiles of the essential oils. Then partial least squares regression (PLSR) was used to elucidate the relationship between sensory attributes and aroma compounds. The result showed that α-pinene, β-thujene, α-terpinolen, β-cubebene, caryophyllene, (Z)β-farnesene, (-)-spathulenol, linalool, camphor, camphene, 4-terpineol, Z-citral and 4-isopropyltoluene were typical aroma compounds covaried with characteristic aroma of Chrysanthemum essential oils. PMID:26735711

  1. Gas chromatography-mass spectrometry metabolomics of goat milk with different polymorphism at the αS1-casein genotype locus.

    Science.gov (United States)

    Caboni, Pierluigi; Murgia, Antonio; Porcu, Alessandra; Demuru, Martina; Pulina, Giuseppe; Nudda, Anna

    2016-08-01

    Hyphenated gas chromatography-mass spectrometry (GC-MS) and multivariate data analysis techniques were used to uncover milk metabolite differences in different αS1-casein genotypes of goats. By a discriminant GC-MS metabolomics approach, we characterized milk polar metabolites of 28 goats. Animals were selected on the basis of their genotypes as 7 goats classified heterozygous for weak or null alleles, 5 for the genotype EE, 9 for the genotypes AE and BE, and finally 7 for the strong genotype AA. Low molecular weight polar metabolite profile was tightly related to the different goat genotypes, milk production, and protein levels. Results of multivariate statistical analysis of GC-MS data demonstrate that different heterozygous and homozygous genotypes expressed different metabolites such as citric and aconitic acid for the strong allele class with different sugars and polyols for the weak class. PMID:27289154

  2. Determination of "new psychoactive substances" in postmortem matrices using microwave derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Margalho, Cláudia; Castanheira, Alice; Real, Francisco Corte; Gallardo, Eugenia; López-Rivadulla, Manuel

    2016-05-01

    Despite worldwide efforts aiming to ban the marketing and subsequent abuse of psychoactive substances such as synthetic cathinones and phenethylamines, there has been an alarming growth of both in recent years. Different compounds similar to those already existing are continuously appearing in the market in order to circumvent the legislation. An analytical methodology has been validated for qualitative and quantitative determinations of D-cathine (D-norpseudoehedrine), ephedrine, methcathinone, 1-(4-methoxyphenyl)-propan-2-amine (PMA), mephedrone, methedrone, 2,5-dimethoxy-4-methylamphetamine (DOM), 4-bromo-2,5-dimethoxyamphetamine (DOB), 2,5-dimethoxyphenethylamine (2C-H), 4-bromo-2,5-dimethoxyphenethylamine (2C-B), 4-iodo-2,5-dimethoxyphenethylamine (2C-I), 2-[2,5-dimethoxy-4-(ethylthio)phenyl]ethanamine (2C-T-2), 2,5-dimethoxy-4-isopropylthiophenethylamine (2C-T-4) and 2-[2,5-dimethoxy-4-(propylthio)phenyl]ethanamine (2C-T-7), in low volumes of vitreous humor (100 μL), pericardial fluid (250 μL) and whole blood (250 μL), using deutered amphetamine, ephedrine and mephedrone as internal standards. The validation parameters included selectivity, linearity and limits of detection and quantification, intra- and interday precision and trueness, recovery and stability. The method included mixed-mode solid phase extraction, followed by microwave fast derivatization and analysis by gas chromatography-mass spectrometry operated in selected ion monitoring mode. The procedure was linear between 5 and 600 ng/mL, with determination coefficients higher than 0.99 for all analytes. Intra- and interday precision ranged from 0.1 to 13.6%, while accuracy variability was within 80-120% interval from the nominal concentration at all studied levels. The extraction efficiencies ranged from 76.6 to 112.8%. Stability was considered acceptable for all compounds in the studied matrices. The developed assay was applied to authentic samples of the Laboratory of Chemistry and Forensic

  3. Direct analysis of acetate and other volatile fatty acids in marine pore water by 2-dimensional ion chromatography-mass spectrometry (2D IC-MS) – A case study from Aarhus Bay (Denmark)

    DEFF Research Database (Denmark)

    Glombitza, Clemens; Lever, Mark; Jørgensen, Bo Barker

    answered. We now use a novel combination of 2-dimensional ion chromatography (ICS 3000, Thermo Scientific) with mass spectrometry (MSQ PLUS, Thermo Scientific) (2D IC-MS) that enables the qualification and quantification of several VFAs directly within marine pore water samples without sample pre...

  4. Prediction of Molar Extinction Coefficients of Proteins and Peptides Using UV Absorption of the Constituent Amino Acids at 214 nm To Enable Quantitative Reverse Phase High-Performance Liquid Chromatography-Mass Spectrometry Analysis

    NARCIS (Netherlands)

    Kuipers, B.J.H.; Gruppen, H.

    2007-01-01

    The molar extinction coefficients of 20 amino acids and the peptide bond were measured at 214 nm in the presence of acetonitrile and formic acid to enable quantitative comparison of peptides eluting from reversed-phase high-performance liquid chromatography, once identified with mass spectrometry (R

  5. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn M.

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  6. Gluten Detection and Speciation by Liquid Chromatography Mass Spectrometry (LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Stephen Lock

    2013-12-01

    Full Text Available Liquid chromatography tandem mass spectrometry (LC-MS/MS has been used historically in proteomics research for over 20 years. However, until recently LC-MS/MS has only been routinely used in food testing for small molecule contaminant detection, for example pesticide and veterinary residue detection, and not as a replacement of microbiological food testing methods, specifically allergen analysis. Over the last couple of years, articles have started to be published which describe the detection of allergens by LC-MS/MS. In this article we will describe how LC-MS/MS can be applied in the area of gluten detection and how it can be used to specifically differentiate the species of gluten used in food, where specific markers for each variety of gluten can be simultaneously acquired and detected at the same time. The article will discuss the effect of variety on the peptide response observed from different wheat grain varieties and will describe the sample preparation protocol which is essential for generating the peptide markers used for speciation.

  7. Online Hydrophobic Interaction Chromatography-Mass Spectrometry for Top-Down Proteomics.

    Science.gov (United States)

    Chen, Bifan; Peng, Ying; Valeja, Santosh G; Xiu, Lichen; Alpert, Andrew J; Ge, Ying

    2016-02-01

    Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.

  8. Liquid Chromatography Mass Spectrometry-Based Proteomics: Biological and Technological Aspects

    Energy Technology Data Exchange (ETDEWEB)

    Karpievitch, Yuliya V.; Polpitiya, Ashoka D.; Anderson, Gordon A.; Smith, Richard D.; Dabney, Alan R.

    2010-12-01

    Mass spectrometry-based proteomics has become the tool of choice for identifying and quantifying the proteome of an organism. Though recent years have seen a tremendous improvement in instrument performance and the computational tools used, significant challenges remain, and there are many opportunities for statisticians to make important contributions. In the most widely used "bottom-up" approach to proteomics, complex mixtures of proteins are first subjected to enzymatic cleavage, the resulting peptide products are separated based on chemical or physical properties and analyzed using a mass spectrometer. The two fundamental challenges in the analysis of bottom-up MS-based proteomics are: (1) Identifying the proteins that are present in a sample, and (2) Quantifying the abundance levels of the identified proteins. Both of these challenges require knowledge of the biological and technological context that gives rise to observed data, as well as the application of sound statistical principles for estimation and inference. We present an overview of bottom-up proteomics and outline the key statistical issues that arise in protein identification and quantification.

  9. Solid-phase microextraction and gas chromatography-mass spectrometry for the rapid screening of triazole residues in wine and strawberries.

    Science.gov (United States)

    Zambonin, C G; Cilenti, A; Palmisano, F

    2002-08-23

    A solid-phase microextraction gas chromatography-mass spectrometry method has been developed for the determination of triazole residues, such as triadimefon, propiconazole, myclobutanil and penconazole. The method has been successfully applied to the analysis of strawberries and wine samples. The procedure is solvent-free, simple and highly sensitive. Within-day and day-to-day RSDs ranged between 2-11% and 7-28%, respectively. Detection limits estimated at a signal-to-noise ratio of 3 ranged between 30 (propiconazole) and 100 ng/kg (triadimefon). Since the detection limits achieved by this method are well below the maximum residue levels for wine (or grapes) and strawberries recommended by the European legislation, it can be conveniently used as a low-cost rapid screening method for the contamination of the considered samples. PMID:12685572

  10. Determination of musty odorants, 2-methylisoborneol and geosmin, in environmental water by headspace solid-phase microextraction and gas chromatography--mass spectrometry.

    Science.gov (United States)

    Saito, Keita; Okamura, Kota; Kataoka, Hiroyuki

    2008-04-01

    A simple and sensitive method for the determination of musty odorants, 2-methylisoborneol (MIB) and geosmin (GSM), in environmental water was developed by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry. MIB and GSM were separated within 10 min using a DB-1 capillary column and detected in the selective ion monitoring mode. HS-SPME using a polydimethylsiloxane/divinylbenzene fiber provided effective sample enrichment, and was carried out by fiber exposition at 70 degrees C for 30 min. Using this method, the calibration curves of MIB and GSM were linear in the range of 0-500 pg/mL, with a correlation coefficient above 0.9977 (n=24). The detection limits (S/N=3) of MIB and GSM were 0.9 and 0.6 pg/mL, respectively. This method was successfully applied to the analysis of environmental water samples without interference peaks.

  11. Hydrolytic degradation of poly(D,L-lactide-co-glycolide 50/50)-di-acrylate network as studied by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    R. Peters; J. Lebouille; B. Plum; P. Schoenmakers; S. van der Wal

    2011-01-01

    The soluble products of the hydrolytic degradation of photochemically cross-linked poly-(d,l-lactide-co-glycolide 50/50)-di-acrylate film were analysed at different stages to obtain insight into the complex (bio)degradation processes. Liquid chromatography-mass spectrometry analyses have been used t

  12. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    Leeuwen, van Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Feijen, J.; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an -caprolactone (CL

  13. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    van Leeuwen, Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Fejen, Jan; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an epsilon-caprolact

  14. Lipid fatty acid profile analyses in liver and serum in rats with nonalcoholic steatohepatitis using improved gas chromatography-mass spectrometry methodology

    Science.gov (United States)

    Fatty acids (FA) are essential components of lipids and exhibit important biological functions. The analyses of FAs are routinely carried out by gas chromatography-mass spectrometry, after multi-step sample preparation. In this study, several key experimental factors were carefully examined, validat...

  15. METHOD 530 DETERMINATION OF SELECT SEMIVOLATILE ORGANIC CHEMICALS IN DRINKING WATER BY SOLID PHASE EXTRACTION AND GAS CHROMATOGRAPHY/ MASS SPECTROMETRY (GC/MS)

    Science.gov (United States)

    1.1. This is a gas chromatography/mass spectrometry (GC/MS) method for the determination of selected semivolatile organic compounds in drinking waters. Accuracy and precision data have been generated in reagent water, and in finished ground and surface waters for the compounds li...

  16. 氟乙酰胺中毒个案的气相色谱-质谱检验%Determination of Fluoroacetamide by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    郑珲; 张春水; 欧阳津

    2004-01-01

    A method of the determination of fluoroacetamide in a poison case was developed. Fluoroacetamide was extracted from stomach tissue, then was derived by PFBBr and determined by gas chromatography mass spectrometry(GC/MS). The results provided scientific proof for the justice identification.

  17. Gas chromatography/mass spectrometry based component profiling and quality prediction for Japanese sake.

    Science.gov (United States)

    Mimura, Natsuki; Isogai, Atsuko; Iwashita, Kazuhiro; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-10-01

    Sake is a Japanese traditional alcoholic beverage, which is produced by simultaneous saccharification and alcohol fermentation of polished and steamed rice by Aspergillus oryzae and Saccharomyces cerevisiae. About 300 compounds have been identified in sake, and the contribution of individual components to the sake flavor has been examined at the same time. However, only a few compounds could explain the characteristics alone and most of the attributes still remain unclear. The purpose of this study was to examine the relationship between the component profile and the attributes of sake. Gas chromatography coupled with mass spectrometry (GC/MS)-based non-targeted analysis was employed to obtain the low molecular weight component profile of Japanese sake including both nonvolatile and volatile compounds. Sake attributes and overall quality were assessed by analytical descriptive sensory test and the prediction model of the sensory score from the component profile was constructed by means of orthogonal projections to latent structures (OPLS) regression analysis. Our results showed that 12 sake attributes [ginjo-ka (aroma of premium ginjo sake), grassy/aldehydic odor, sweet aroma/caramel/burnt odor, sulfury odor, sour taste, umami, bitter taste, body, amakara (dryness), aftertaste, pungent/smoothness and appearance] and overall quality were accurately explained by component profiles. In addition, we were able to select statistically significant components according to variable importance on projection (VIP). Our methodology clarified the correlation between sake attribute and 200 low molecular components and presented the importance of each component thus, providing new insights to the flavor study of sake. PMID:25060729

  18. The Circadian Variation of Cortisol Secretion in Patients with Anorexia Nervosa in Childhood and Adolescence after Recovery of Body Weight by Treatment Using Gas Chromatography/Mass Spectrometry in Selected Ion Monitoring

    OpenAIRE

    Homma, Keiko; Sato, Akihiro; Watanabe, Hisako; Hasegawa, Tomonobu

    2007-01-01

    Anorexia nervosa (AN) is a chronic psychiatric disorder which is characterized by patient-induced weight loss. Complications in many organ systems can be seen in AN such as cardiovascular, gastrointestinal, and endocrine system including hypothalamic-pituitary-adrenal axis, even after recovery of body weight by treatment. Urinary steroid profile analysis using gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) has been reported to be useful for the diagnosis of abno...

  19. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  20. Determination of naphthenic acid profile in Ghana's Jubilee Oil using gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Crude oil is the life-blood of the global economy. Its importance stems from the fact that it is a base product for a wide variety of goods [Drugs, Plastics, Liquefied Petroleum Gas (LPG)]. The oil discovery (over 3 billion barrel reserves in hydrocarbon and gas), about 60 km offshore between the Deepwater Tano and Cape Three Points Block in South western Ghana is a valuable natural asset and it has the potential of boosting the Ghanaian economy. During petroleum processing, various waste products are generated. One of such products is Naphthenic acids (NA). Naphthenic acids are organic acids naturally occurring in crude oil and a constituent of waste associated with oil refinery. Naphthenic acids serve as biomarkers for identification of the source of crude oil. The presence of Naphthenic acid in the aquatic environment causes toxic effects due to their weak biodegradable nature; the toxicity of Naphthenic acids depends on the class of Naphthenic acids present in the crude oil. The study assessed the profile of Naphthenic acids in Ghana’s Jubilee crude oil using Low Resolution Electron Impact – Gas Chromatography Mass Spectrometry (LREI-GCMS) after isolation of Naphthenic acids in the Jubilee oil by a modified Kupchan’s Partitioning Process. The Mass Spectrometric (MS) Work Station Software was used for the identification of the Naphthenic acids present in the Jubilee crude oil. The quality of the Jubilee oil was also evaluated through the use of some key physico-chemical parameters [Total Acid Number (TAN), Sulphur Content, Viscosity, Pour Point, Flashpoint, Water Content and Densities] based on the American Standards for Testing and Materials (ASTM, 2007). The Total Acid Number was determined by Colorimetric Titration (ASTM D974); Sulphur Content by X-ray Fluorescent Spectrometry (ASTM D4294); Pour Point by the use of the SETA cloud and Pour Point Refrigerator Technique (ASTM D97); Viscosity by Gravity Timed Method (ASTM D445); Density by the Hydrometer

  1. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  2. Quantification of almond skin polyphenols by liquid chromatography-mass spectrometry

    Science.gov (United States)

    Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic compounds from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-da...

  3. Analysis of protein composition of red wine in comparison with rosé and white wines by electrophoresis and high-pressure liquid chromatography-mass spectrometry (HPLC-MS).

    Science.gov (United States)

    Wigand, Petra; Tenzer, Stefan; Schild, Hansjoerg; Decker, Heinz

    2009-05-27

    Wine proteins not only influence wine stability but are also being discussed as potential allergens. Proteins from red, rosé, and white wines were enriched by dialysis and lyophilization followed by separation by SDS-PAGE. Significant differences were detected in the protein compositions of the analyzed wine varieties, and the major protein bands were identified by mass spectrometry after in-gel digestion with trypsin. In German Portugieser red wine, a total of 121 tryptic peptides were identified, which were attributed to 12 grape proteins and 6 proteins derived from yeast. Among the identified constituents are several proteins considered to influence wine stability and previously described potential grape allergens. The pathogenesis-related proteins represent the main proteins in all of the wines, but only some red wines show a band with a molecular mass of 12 kDa, identified as a lipid transfer protein (LTP). The occurrence and distribution of LTP depend on the wine variety.

  4. Identification of bound alcohols in soil humic acids by gas chromatography-mass spectrometry

    OpenAIRE

    Berthier, Gersende; Dou, Sen; Peakman, Torren; Lichtfouse, Eric

    2000-01-01

    International audience Humic acids are complex, partly macromolecular, yellow-brownish substances occurring in soils, waters and sediments. In order to shed some light on their molecular structure, crop humic acids were cleaved by alkaline hydrolysis (KOH). The products were fractionated by thin layer chromatography to give mono-alcohols which were analysed as acetate derivatives by gas chromatography coupled to mass spectrometry. Linear alcohols, sterols, stanols and plant-derived triterp...

  5. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    OpenAIRE

    Zoraida Sosa-Ferrera; Cristina Mahugo-Santana; José Juan Santana-Rodríguez

    2012-01-01

    The combination of liquid chromatography (LC) with mass spectrometry (MS) in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others) since the same ones are continuously being released in the environment mai...

  6. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    OpenAIRE

    2014-01-01

    Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS) using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs). The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrumen...

  7. Liquid chromatography mass spectrometry-based proteomics: Biological and technological aspects

    OpenAIRE

    Karpievitch, Yuliya V.; Polpitiya, Ashoka D.; Anderson, Gordon A.; Smith, Richard D.; Dabney, Alan R.

    2011-01-01

    Mass spectrometry-based proteomics has become the tool of choice for identifying and quantifying the proteome of an organism. Though recent years have seen a tremendous improvement in instrument performance and the computational tools used, significant challenges remain, and there are many opportunities for statisticians to make important contributions. In the most widely used “bottom-up” approach to proteomics, complex mixtures of proteins are first subjected to enzymati...

  8. Stir-bar-sorptive extraction and liquid desorption combined with large-volume injection gas chromatography-mass spectrometry for ultra-trace analysis of musk compounds in environmental water matrices.

    Science.gov (United States)

    Silva, Ana Rita M; Nogueira, J M F

    2010-03-01

    Stir-bar-sorptive extraction with liquid desorption followed by large-volume injection and capillary gas chromatography coupled to mass spectrometry in selected ion monitoring acquisition mode (SBSE-LD/LVI-GC-MS(SIM)) has been developed to monitor ultra-traces of four musks (celestolide (ADBI), galaxolide (HHCB), tonalide (AHTN) and musk ketone (MK)) in environmental water matrices. Instrumental calibration (LVI-GC-MS(SIM)) and experimental conditions that could affect the SBSE-LD efficiency are discussed. Assays performed on 30-mL water samples spiked at 200 ng L(-1) under optimized experimental conditions yielded recoveries ranging from 83.7 ± 8.1% (MK) to 107.6 ± 10.8% (HHCB). Furthermore, the experimental data were in very good agreement with predicted theoretical equilibria described by octanol-water partition coefficients (K (PDMS/W) ≈ K (O/W)). The methodology also showed excellent linear dynamic ranges for the four musks studied, with correlation coefficients higher than 0.9961, limits of detection and quantification between 12 and 19 ng L(-1) and between 41 and 62 ng L(-1), respectively, and suitable precision (ultra-trace level, overcoming several disadvantages presented by other sample-preparation techniques. PMID:20049588

  9. Combining peak- and chromatogram-based retention time alignment algorithms for multiple chromatography-mass spectrometry datasets

    Directory of Open Access Journals (Sweden)

    Hoffmann Nils

    2012-08-01

    Full Text Available Abstract Background Modern analytical methods in biology and chemistry use separation techniques coupled to sensitive detectors, such as gas chromatography-mass spectrometry (GC-MS and liquid chromatography-mass spectrometry (LC-MS. These hyphenated methods provide high-dimensional data. Comparing such data manually to find corresponding signals is a laborious task, as each experiment usually consists of thousands of individual scans, each containing hundreds or even thousands of distinct signals. In order to allow for successful identification of metabolites or proteins within such data, especially in the context of metabolomics and proteomics, an accurate alignment and matching of corresponding features between two or more experiments is required. Such a matching algorithm should capture fluctuations in the chromatographic system which lead to non-linear distortions on the time axis, as well as systematic changes in recorded intensities. Many different algorithms for the retention time alignment of GC-MS and LC-MS data have been proposed and published, but all of them focus either on aligning previously extracted peak features or on aligning and comparing the complete raw data containing all available features. Results In this paper we introduce two algorithms for retention time alignment of multiple GC-MS datasets: multiple alignment by bidirectional best hits peak assignment and cluster extension (BIPACE and center-star multiple alignment by pairwise partitioned dynamic time warping (CeMAPP-DTW. We show how the similarity-based peak group matching method BIPACE may be used for multiple alignment calculation individually and how it can be used as a preprocessing step for the pairwise alignments performed by CeMAPP-DTW. We evaluate the algorithms individually and in combination on a previously published small GC-MS dataset studying the Leishmania parasite and on a larger GC-MS dataset studying grains of wheat (Triticum aestivum. Conclusions We

  10. Chapter 3. Determination of semivolatile organic compounds and polycyclic aromatic hydrocarbons in solids by gas chromatography/mass spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Burkhardt, Mark R.; Burbank, Teresa L.; Olson, Mary C.; Iverson, Jana L.; Schroeder, Michael P.

    2006-01-01

    A method for the determination of 38 polycyclic aromatic hydrocarbons (PAHs) and semivolatile organic compounds in solid samples is described. Samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from the solid sample twice at 13,800 kilopascals; first at 120 degrees Celsius using a water/isopropyl alcohol mixture (50:50, volume-to-volume ratio), and then the sample is extracted at 200 degrees Celsius using a water/isopropyl alcohol mixture (80:20, volume-to-volume ratio). The compounds are isolated using disposable solid-phase extraction (SPE) cartridges containing divinylbenzene-vinylpyrrolidone copolymer resin. The cartridges are dried with nitrogen gas, and then sorbed compounds are eluted from the SPE material using a dichloromethane/diethyl ether mixture (80:20, volume-to-volume ratio) and passed through a sodium sulfate/Florisil SPE cartridge to remove residual water and to further clean up the extract. The concentrated extract is solvent exchanged into ethyl acetate and the solvent volume reduced to 0.5 milliliter. Internal standard compounds are added prior to analysis by capillary-column gas chromatography/mass spectrometry. Comparisons of PAH data for 28 sediment samples extracted by Soxhlet and the accelerated solvent extraction (ASE) method described in this report produced similar results. Extraction of PAH compounds from standard reference material using this method also compared favorably with Soxhlet extraction. The recoveries of PAHs less than molecular weight 202 (pyrene or fluoranthene) are higher by up to 20 percent using this ASE method, whereas the recoveries of PAHs greater than or equal to molecular weight 202 are equivalent. This ASE method of sample extraction of solids has advantages over conventional Soxhlet extraction by increasing automation of the extraction process, reducing extraction time, and using less solvent. Extract cleanup also is greatly simplified because SPE replaces

  11. 气-质联用分析雷公藤中萜和生物碱%Gas chromatography-mass spectrometry analysis of terpenes and alkaloids in Tripterygium wilfordii

    Institute of Scientific and Technical Information of China (English)

    郭志峰; 武晓阳; 张晓璇; 高志力

    2013-01-01

    Terpenes and Alkaloids in Tripterygium wilfordii were analyzed using GC-MS. Before alkaloids and terpenes were striped the extracted liquids of Tripterygium wilfordii had been defatted by e-ther, which was separated 130 peaks by gas chromatographic. 58 compounds were identified through their corresponding to the mass spectrometry. These substances included mainly alcohols, aldehydes, acids, esters, ether, terpenoids and alkyls etc. The liquid extracted alkaloids were separated 111 peaks and 40 substances were identified. The relative content of terpenoids and alkaloids were 30% , and others were mainly acid compound and lipid compounds.%采用GC-MS法对雷公藤中的帖和生物碱进行了定性分析.雷公藤提取液先经去脂,再萃取萜和生物碱.去除的脂类经气相色谱分析共分离了130个峰,由它们所对应的质谱,通过谱图检索和谱图解析,鉴定推断出58种化合物.这些物质主要为醇、醛、酸、酯、醚、酮等.雷公藤生物碱提取液色谱分离出111个峰,鉴定出40种物质.其中萜类和生物碱相质量分数30%,其余化合物绝大多数是酸脂类化合物.

  12. Stress degradation study and structure characterization of oxidation degradation product of dexlansoprazole using liquid chromatography-mass spectrometry/time of flight, liquid chromatography-tandem mass spectrometry and nuclear magnetic resonance

    Institute of Scientific and Technical Information of China (English)

    Lakkireddy PRAKASH; M HIMAJA

    2016-01-01

    The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation( ICH)prescribed stress conditions. The drug was found to be more labile under acid,base,neutral,oxidative hydrolysis and thermal stress,while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stability-indicating method. Liquid chromatography-mass spectrometry( LC-MS)analysis was performed for all the deg-radation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools,viz. preparative high performance liquid chromatography( HPLC),liquid chromatography-mass spectrometry/time of flight( LC-MS/TOF),liquid chromatography-tandem mass spectrometry( LC-MS/MS),and nuclear magnetic resonance( NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole,which helps in the development and stability study of active pharmaceutical ingredients and formulated products.

  13. Non-targeted metabolomics study for the analysis of chemical compositions in three types of tea by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry%基于气相色谱-质谱联用与液相色谱-质谱联用的非靶向代谢组学用于3类茶叶中化学成分分析

    Institute of Scientific and Technical Information of China (English)

    张磊; 曾仲大; 叶国注; 赵春霞; 路鑫; 许国旺

    2014-01-01

    茶叶中的化学成分是构成其风味特征的物质基础。本研究建立了基于气相色谱-质谱联用和液相色谱-质谱联用的非靶向代谢组学方法。完成预处理及分析条件优化后,使用标准样品考察方法的线性、回收率及重复性,结果表明方法整体稳定且结果可靠。将该方法用于绿茶、乌龙茶和红茶中化学成分的分析。通过超声辅助溶剂提取及气相色谱-质谱联用分析共获得1812个特征峰,而使用加热溶剂提取及液相色谱-质谱联用分析可获得2608个特征峰。结合保留规律及质谱数据库,共定性173种化合物(109种随后经标准样品验证),其中只有9种化合物在上述两类分析中被同时检出,表明方法互补性良好。3类茶叶数据的偏最小二乘判别分析结果表明,三者间存在显著差异。结合模型的变量重要因子( VIP)与非参数检验共筛选出90种化合物,其中包含儿茶素、氨基酸、糖、有机酸和黄酮苷类等众多与茶叶滋味密切相关的化学成分。%Tea is one of the most widely consumed beverages in the world for its benefits to daily life and health. To discover the difference and correlation of chemical compositions in the three typical types of tea,a non-targeted metabolomics method was developed. After the optimization of extraction methods,gas chroma-tography-time-of-flight mass spectrometry and liquid chromatography-quadrupole time-of-flight mass spectrome-try were applied for metabolomics analysis,1 812 and 2 608 features were obtained,respectively. By comparing with the known compounds in public and/or commercial databases,173 compounds were tentatively identified, and 109 of them were experimentally confirmed by standards. Totally,33 tea samples including 12,12 and 9 samples of green,oolong and black tea,respectively,were analyzed by using the above two methods. Multiva-riate analysis,Mann-Whitney U test and hierarchical cluster

  14. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  15. Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study.

    Science.gov (United States)

    Jalali, Amir; Hatamie, Amir; Saferpour, Tahere; Khajeamiri, Alireza; Safa, Tahere; Buazar, Foad

    2016-01-01

    In this study, a simple and reliable method by gas chromatograph-mass spectrometry (GC-MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC-MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method showed that unambiguous identification can be achieved for MDMA from 3, 4-methylenedioxyamphetamine (MDA), Amphetamine (AM), methamphetamine (MA) and ketamine (Keta) compounds, respectively. The experimental results indicated the acceptable time window without interfering peaks. It is found that GC-MS was provided a suitable and rapid identification approach for MDMA (Ecstacy) tablets, particularly in the Forensic labs. Consequently, the intense MDMA levels would support the police to develop a simple quantification of impurity in Ecstasy tablets. PMID:27610162

  16. Determination of heat purgeable and ambient purgeable volatile organic compounds in water by gas chromatography/mass spectrometry

    Science.gov (United States)

    Rose, Donna L.; Sandstrom, Mark W.; Murtagh, Lucinda K.

    2016-09-08

    Two new analytical methods have been developed by the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) that allow the determination of 37 heat purgeable volatile organic compounds (VOCs) (USGS Method O-4437-16 [NWQL Laboratory Schedule (LS) 4437]) and 49 ambient purgeable VOCs (USGS Method O-4436-16 [NWQL LS 4436]) in unfiltered water. This report documents the procedures and initial performance of both methods. The compounds chosen for inclusion in the methods were determined as having high priority by the USGS National Water-Quality Assessment (NAWQA) Program. Both methods use a purge-and-trap technique with gas chromatography/mass spectrometry. The compounds are extracted from the sample by bubbling helium through a 25-milliliter sample. For the polar and less volatile compounds, the sample is heated at 60 degrees Celsius, whereas the less polar and more volatile compounds are purged using a separate analytical procedure at ambient temperature. The compounds are trapped on a sorbent trap, desorbed into a gas chromatograph/mass spectrometer for separation, and then identified and quantified. Sample preservation is recommended for both methods by adding a 1:1 solution of hydrochloric acid (HCl [1:1]) to water samples to adjust the pH to 2. Analysis within 14 days from sampling is recommended.The heat purgeable method (USGS Method O-4437-16) operates with the mass spectrometer in the simultaneous full scan/selected ion monitoring mode. This method supersedes USGS Method O-4024-03 (NWQL LS 4024). Method detection limits (MDLs) for fumigant compounds 1,2-dibromoethane, 1,2-dichloropropane, 1,2,3-trichloropropane, chloropicrin, and 1,2-dibromo-3-chloropropane range from 0.002 to 0.010 microgram per liter (µg/L). The MDLs for all remaining heat purgeable VOCs range from 0.006 µg/L for tert-butyl methyl ether to 3 µg/L for alpha-terpineol. Calculated holding times indicate that 36 of the 37 heat purgeable VOCs are stable for a minimum of 14 days

  17. Dual dispersive liquid-liquid microextraction for determination of phenylpropenes in oils by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsai, Chia-Ju; Li, Jih-Heng; Feng, Chia-Hsien

    2015-09-01

    A novel, simple and quick sample preparation method was developed and used for pre-concentration and extraction of six phenylpropenes, including anethole, estragole, eugenol, methyl eugenol, safrole and myristicin, from oil samples by dual dispersive liquid-liquid microextraction. Gas chromatography-mass spectrometry was used for determination and separation of compounds. Several experimental parameters affecting extraction efficiency were evaluated and optimized, including forward-extractant type and volume, surfactant type and concentration, water volume, and back-extractant type and volume. For all analytes (10-1000ng/mL), the limits of detection (S/N≧3) ranged from 1.0 to 3.0ng/mL; the limits of quantification (S/N≧10) ranged from 2.5 to 10.0ng/mL; and enrichment factors ranged from 3.2 to 37.1 times. Within-run and between-run relative standard deviations (n=6) were less than 2.61% and less than 4.33%, respectively. Linearity was excellent with determination coefficients (r(2)) above 0.9977. The experiments showed that the proposed method is a simple, effective, and environmentally friendly method of analyzing phenylpropenes in oil samples.

  18. LaCyTools: A Targeted Liquid Chromatography-Mass Spectrometry Data Processing Package for Relative Quantitation of Glycopeptides.

    Science.gov (United States)

    Jansen, Bas C; Falck, David; de Haan, Noortje; Hipgrave Ederveen, Agnes L; Razdorov, Genadij; Lauc, Gordan; Wuhrer, Manfred

    2016-07-01

    Bottom-up glycoproteomics by liquid chromatography-mass spectrometry (LC-MS) is an established approach for assessing glycosylation in a protein- and site-specific manner. Consequently, tools are needed to automatically align, calibrate, and integrate LC-MS glycoproteomics data. We developed a modular software package designed to tackle the individual aspects of an LC-MS experiment, called LaCyTools. Targeted alignment is performed using user defined m/z and retention time (tr) combinations. Subsequently, sum spectra are created for each user defined analyte group. Quantitation is performed on the sum spectra, where each user defined analyte can have its own tr, minimum, and maximum charge states. Consequently, LaCyTools deals with multiple charge states, which gives an output per charge state if desired, and offers various analyte and spectra quality criteria. We compared throughput and performance of LaCyTools to combinations of available tools that deal with individual processing steps. LaCyTools yielded relative quantitation of equal precision (relative standard deviation https://github.com/Tarskin/LaCyTools ). PMID:27267458

  19. Evaluation of a sunscreen photoprotective effect by ascorbic acid assessment in human dermis using microdialysis and gas chromatography mass spectrometry.

    Science.gov (United States)

    Lévêque, Nathalie; Mac-Mary, Sophie; Muret, Patrice; Makki, Safwat; Aubin, Francois; Kantelip, Jean-Pierre; Heusèle, Catherine; S, Schnebert; Humbert, Philippe

    2005-03-01

    Ultraviolet irradiation causes adverse effects like sunburn, photosensitivity reactions or immunologic suppression. The aim of this study was to evaluate the photo-protective outcome of a sunscreen cream (SPF8) by the determination of erythema indexes and the assessment of ascorbic acid and its metabolites in human dermis. These substances were used as markers of oxidative effect. Eight healthy female subjects were enrolled in this study. Two abdominal areas were exposed to solar simulated irradiation with three minimal erythema dose, one with SPF8 application and the other site without SPF8 application. Two other areas were used as control, one without SPF8 application and the other site after SPF8 application. Ascorbic acid and its metabolites (dehydroascorbic acid, threonic acid, oxalic acid and xylose) were collected from human dermis by microdialysis and assessed by gas chromatography mass spectrometry. Irradiated site without sunscreen application had significantly demonstrated lower dermis ascorbic acid concentrations and a higher erythema index than the three other sites (P creams against undesirable UV effects. PMID:15740589

  20. [Determination of bisphenol A from toys and food contact materials by derivatization and gas chromatography-mass spectrometry].

    Science.gov (United States)

    Gao, Yonggang; Zhang, Yanyan; Gao, Jianguo; Zhang, Huiling; Zheng, Lisha; Chen, Jing

    2012-10-01

    A method was developed for the determination of bisphenol A (BPA) in toys and food contact materials. The BPA was extracted with Soxhlet extraction method from the sample and reacted with acetic anhydride. The final product was determined by gas chromatography-mass spectrometry (GC-MS). To achieve the optimum derivatization performance, the derivatization time and dosage of derivatization reagent etc. were investigated. Under the optimized experimental conditions, the final product was stable and the peak shape was good. The linearity of the derivative was good in the range of 0.05 to 50 mg/L with the correlation coefficient (r2) above 0.999. The recoveries ranged from 80% to 93% at the spiked levels of 0.05, 1.00, 10.00 mg/kg with the relative standard deviations (RSDs) less than 3.7%. The limit of detection (S/N = 3) was 10 microg/kg. The method is accurate and has high recovery. The method is suitable for the inspection of bisphenol A in toys and food contact materials.

  1. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Dang, Ngoc A; Mourão, Marta; Kuijper, Sjoukje; Walters, Elisabetta; Janssen, Hans-Gerd; Kolk, Arend H J

    2015-04-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in bacterial cultures. This model provided better than 95% accuracy. In our current work a hexane/methanol/water extraction followed by a solid phase extraction (SPE) clean-up procedure was developed for use before THM-GC-MS, to make the test suitable for the identification of mycobacteria in sputum. The 20 biomarker model had to be adapted since many compounds were also found in the sputum of non-tuberculosis patients. An algorithm was established based on tuberculostearic acid, hexacosanoic acid and mycoserosates. The detection limit of the method was approximately 1×10(4) bacteria/mL sputum. Sputum specimens from 32 patients from South Africa who were suspected of having tuberculosis were blindly tested using the new method. Eight of the nine culture-positive sputum specimens were detected by the new SPE-THM-GC-MS method, resulting in a sensitivity of 89%. The specimen that was missed by the new method was also microscopy negative. The specificity of the test was 100%; all 23 microscopy- and culture-negative specimens were correctly identified as negative by SPE-THM-GC-MS. PMID:25728368

  2. Simultaneous Determination of 10 Photoinitiators in Milk by Solid-Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Liu, Pengyan; Zhao, Chunxia; Zhang, Yajing; Chen, Yanjie

    2016-05-01

    Photoinitiators (PIs) are widely used in food packaging materials, can migrate easily from packaging materials to food, and cause food contamination. It is essential to establish a method of determining PIs residues in food. A new method for simultaneously determining 10 kinds of PIs in milk has been established by using solid-phase microextraction (SPME) combined with a simple method of protein precipitation as the pretreatment approach and gas chromatography/mass spectrometry as the detecting technique. The limits of detection for 10 PIs in different milks were between 0.05 and 1.4 μg/L (skimmed milk), between 0.07 and 2.2 μg/L (semi-skimmed milk), between 0.11 and 4.4 μg/L (whole milk), respectively. The recoveries were from 71.5% to 133.5%, and the relative standard deviations were less than 15%. Twelve kinds of packed milk with different brands and fat contents were determined using this method. PMID:27010861

  3. Automated storage of gas chromatography-mass spectrometry data in a relational database to facilitate compound screening and identification.

    Science.gov (United States)

    Staeb, J A; Epema, O J; van Duijn, P; Steevens, J; Klap, V A; Freriks, I L

    2002-10-18

    This paper describes a database containing massspectra from gas chromatography-mass spectrometry(GC-MS) measurements as a tool for easy screening for multiple compounds. In this way additional compounds can be reported from the same run together with routine pesticide monitoring with little effort. The relevant analytical data from the GC-MS measurements are transferred automatically to a database. Search algorithms in the database, containing the US EPA and Dutch NEN GC-MS identification criteria as standard settings, are used to identify compounds in the data. Screening of samples analysed in our laboratory show the ubiquitous presence of--up until now in monitoring largely overlooked--compounds in surface waters in The Netherlands. Most frequently found compounds include TAED (complexing agent), 2-methyl quinoline (industrial solvent), atrazin and desethylatrazin (pesticide and degradation product), caffeine (human consumption), surfinol-104 (anti foaming agent), HHCB (Galaxolide) and AHTN (Tonalide; fragrances). The database can also be used to quickly search a large number of datafiles for rare contaminants. This way, some interesting compounds such as pentoxifilin (a pharmaceutical) and Irgarol 1051 (an antifouling compound) were found. PMID:12458939

  4. Identification of fentanyl metabolites in rat urine by gas chromatography-mass spectrometry with stable-isotope tracers

    Energy Technology Data Exchange (ETDEWEB)

    Goromaru, T.; Matsuura, H.; Furuta, T.; Baba, S.; Yoshimura, N.; Miyawaki, T.; Sameshima, T.

    The metabolites of fentanyl (l), which has been widely used as a neuroleptic analgesic agent, were identified in urine of rats by gas chromatography-mass spectrometry combined with a stable-isotope tracer technique. After the oral administration of an equimolar mixture of l and deuterium-labeled l (l/l-d5), the urinary metabolites were extracted with chloroform at pH 9.0. Extracts were derivatized and analyzed by GC/MS. Metabolites were identified by the presence of doublet ion peaks separated by 5 amu, and chemical structures were established from analyses of fragmentation pathways. The metabolites were identified as 4-N-(N-propionylanilino)-piperidine, 4-N-(N-hydroxypropionylanilino)piperidine, 4-N-(N-propionylanilino) hydroxypiperidine, 1-(2-phenethyl)-4-N-(N-hydroxypropionylanilino)piperidine and 1-(2-phenethyl)-4-N-(N-propionylanilino)hydroxypiperidine. These metabolites, together with unchanged l, were also detected in urine of rats receiving l/l-d5 intravenously, by selected-ion monitoring of the specific cluster ions.

  5. Development of a Gas Chromatography-Mass Spectrometry Method for the Quantification of Glucaric Acid Derivatives in Beverage Substrates

    Directory of Open Access Journals (Sweden)

    Ana Paula Craig

    2014-01-01

    Full Text Available A gas chromatography-mass spectrometry (GC-MS method using the standard addition methodology was developed for the determination of glucuronolactone (GL and glucuronic acid (DGuA in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyltrifluoroacetamide and TMCS (trimethylchlorosilane to silylate the analytes. The sample pretreatment required no extraction, filtration, or reduction step prior to the injection. The quantification of the analytes was performed using a five-point standard addition protocol. The proposed method presented excellent intraday precision (%RSD 0.995 and acceptable linearity for DGuA calibration curves (correlation coefficients > 0.97. The estimated limits of detection (LOD and quantification (LOQ for GL ranged from 0.006 ppm to 0.14 ppm, and 0.02 ppm to 0.47 ppm, respectively. The estimated LOD and LOQ for DGuA determination ranged, respectively, from 0.06 ppm to 1.1 ppm and 0.2 ppm to 3.8 ppm. The results demonstrated that the method should be regarded as a reliable alternative to the simultaneous determination of GL and DGuA.

  6. Development of a gas chromatography-mass spectrometry method for the quantification of glucaric Acid derivatives in beverage substrates.

    Science.gov (United States)

    Craig, Ana Paula; Fields, Christine C; Simpson, John V

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method using the standard addition methodology was developed for the determination of glucuronolactone (GL) and glucuronic acid (DGuA) in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) and TMCS (trimethylchlorosilane) to silylate the analytes. The sample pretreatment required no extraction, filtration, or reduction step prior to the injection. The quantification of the analytes was performed using a five-point standard addition protocol. The proposed method presented excellent intraday precision (%RSD 0.995) and acceptable linearity for DGuA calibration curves (correlation coefficients > 0.97). The estimated limits of detection (LOD) and quantification (LOQ) for GL ranged from 0.006 ppm to 0.14 ppm, and 0.02 ppm to 0.47 ppm, respectively. The estimated LOD and LOQ for DGuA determination ranged, respectively, from 0.06 ppm to 1.1 ppm and 0.2 ppm to 3.8 ppm. The results demonstrated that the method should be regarded as a reliable alternative to the simultaneous determination of GL and DGuA. PMID:25024704

  7. Applications of Hadamard transform-gas chromatography/mass spectrometry for the detection of hexamethyldisiloxane in a wafer cleanroom.

    Science.gov (United States)

    Cheng, Yuan-Kai; Lin, Cheng-Huang; Kuo, Samuel; Yang, Jonathan; Hsiung, Szu-Yuan; Wang, Jia-Lin

    2012-01-13

    The Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) technique was successfully employed for the detection of hexamethyldisiloxane (HMDSO, C(6)H(18)OSi(2)) at the sub-nL/L level in a semiconductor wafer cleanroom. Indoor air samples were collected from the room, according to EPA Method TO-17 using a Tedlar bag where the air samples were allowed to pass through an absorption tube for 24 h. The condensed components were then heated and simultaneously injected into a GC column through a Hadamard-injector, which was operated in accordance with the Hadamard codes. Compared to the single injection used in most GC/MS systems, the signal-to-noise (S/N) ratios were substantially improved after the inverse Hadamard transformation of the encoded chromatogram. Under optimized conditions, when cyclic S-matrix orders of 255, 1023 and 2047 were used, the S/N ratios of the HMDSO signals were substantially improved by 7.4-, 15.1- and 20.1-fold, respectively. These improvements are in good agreement with theoretically calculated values (8.0-, 16.0- and 22.6-fold, respectively). We found that when the HT-GC/MS technique was applied, HMDSO could be detected at the 0.1 nL/L level.

  8. Determination of seventeen polar/thermolabile pesticides in apples and apricots by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Zrostlíková, Jitka; Hajslová, Jana; Kovalczuk, Tomás; Stĕpán, Radim; Poustka, Jan

    2003-01-01

    A simple liquid chromatography/mass spectrometry (LC/MS) approach for the determination of widely used representatives of polar/thermolabile pesticides in fruits was developed and validated. The group of pesticides comprised benzimidazoles and azoles (carbendazim, thiabendazole, imazalil, propiconazole, prochloraz, epoxiconazole, flusilazole, tebuconazole, bitertanol); N-methylcarbamates (carbaryl, carbofuran, methiocarb); and phenylureas and benzoylphenylureas (linuron, diflubenzuron, triflumuron, teflubenzuron, flufenoxuron). Matrixes (apple, apricot) were extracted with acetonitrile and crude extracts were cleaned up by solid-phase extraction (SPE) using either mixed cation exchange or hydrophilic lipophilic balance cartridges. LC separation of pesticides was performed on a reversed-phase column, Discovery C18. Electrospray ionization and ion trap MS/MS detection were applied. For most pesticides, overall recoveries ranged from 75 to 122%, and repeatability (as relative standard deviation) from 5 repetitive determinations of recovery ranged from 3 to 21%. Carbofuran was the only compound for which recovery was not satisfactory due to its loss in the SPE cleanup step. Limits of detection were 0.1-3 microg/kg for benzimidazole and azole fungicides and carbamate insecticides. For urea insecticides, detection limits were slightly higher (3-10 microg/kg). PMID:12852583

  9. A study on the separation and extraction of polycyclic aromatic hydrocarbons in water sample by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    The separation and sample extraction methods of 19 polycyclic aromatic hydrocarbons (PAHS) in water samples were investigated by gas chromatography/mass spectrometry (GC/MS) and some ex-traction methods involved liquid-liquid extraction, disk extraction and solid-phase extraction methods. The separation of 19 PAHs was possible by partial variation of oven temperature of GC/MS in temperature range 80∼310.deg.C. Extraction procedures of PAHs in water samples were somewhat modified and com-pared as extraction recoveries and the simplicity of methods. Extraction recoveries of PAHs were 71.3∼109.5% by liquid-liquid extraction method. By using disk extraction, good extraction recoveries (80.7∼94.9%) were obtained in case of C18 disk extraction method by filtration. And extraction recoveries of PAHs by C18 solid-phase were in the range of 51.8∼77.9%. Method detection limits (S/N=5) of 19 PAHs were in the range of 0.25∼6.25 ppb by liquid-liquid extraction and solid-phase extraction and 0.05∼1.25 ppb by disk extraction methods

  10. Simultaneous enantioselective determination of amphetamine and congeners in hair specimens by negative chemical ionization gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martins, Liliane; Yegles, Michel; Chung, Heesun; Wennig, Robert

    2005-10-15

    Enantioselective quantification of amphetamine (AM), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) enantiomers in hair using gas chromatography-mass spectrometry (GC-MS) is described. Hair specimens were digested with 1M sodium hydroxide at 100 degrees C for 30 min and extracted by a solid phase procedure using Cleanscreen ZSDAU020. Extracted analytes were derivatised with (S)-heptafluorobutyrylprolyl chloride and the resulting diastereoisomers were quantified by GC-MS operating in the negative chemical ionization mode. Extraction yields were between 73.0 and 97.9%. Limits of detection varied in the range of 2.1-45.9 pg/mg hair, whereas the lowest limits of quantification varied between 4.3 and 91.8 pg/mg hair. Intra- and inter-assay precision and respective accuracy were acceptable. The enantiomeric ratios (R versus S) of AM, MA, MDA, MDMA and MDEA were determined in hair from suspected amphetamine abusers. Only MA and AM enantiomers were detectable in this collective and the quantification data showed in most cases higher concentrations of (R)-MA and (R)-AM than those of the corresponding (S)-enantiomers. PMID:16154523

  11. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Maryam Zokaei

    2016-02-01

    Full Text Available Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatization and measurement processes were optimized using the one-factor-at-a-time method. The peak areas were assumed as the GC-MS response to evaluate the extraction efficiency of acrylamide, and optimization for all tests was performed two times. Figures of merit of the proposed method were evaluated. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method. Results: The optimum amounts of effective parameters, including derivatization temperature at 25oC, derivatization time (40 min, xanthydrol volume (40 µL, extracted solvent volume (500 µL and pH=7 were determined. The figures of merit for the proposed method were at the ideal range. The maximum and minimum amounts of acrylamide in the chip samples were also measured. Conclusions: The performance and reliability of proposed method as a simple, efficient and rapid method for determining acrylamide in potato chip samples were demonstrated.

  12. Solid phase microextraction and gas chromatography-mass spectrometry methods for residual solvent assessment in seized cocaine and heroin.

    Science.gov (United States)

    Cabarcos, Pamela; Herbello-Hermelo, Paloma; Álvarez-Freire, Iván; Moreda-Piñeiro, Antonio; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar

    2016-09-01

    A simple sample pre-treatment method based on solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized and validated for the assessment of 15 residual solvents (2-propanol, 2-methylpentane, 3-methylpentane, acetone, ethyl acetate, benzene, hexane, methylcyclohexane, methylcyclopentane, m-xylene, propyl acetate, toluene, 1,2,4-trimethylbenzene, dichloromethane, and ethylbenzene) in seized illicit cocaine and heroin. DMSO and DMF as sample diluents were found to offer the best residual solvent transference to the head space for further adsorption onto the SPME fiber, and the developed method therefore showed high sensitivity and analytical recovery. Variables affecting SPME were fully evaluated by applying an experimental design approach. Best conditions were found when using an equilibration time of 5 min at 70 °C and headspace sampling of residual solvents at the same temperature for 15 min. Method validation, performed within the requirements of international guidelines, showed excellent sensitivity, as well as intra- and inter-day precision and accuracy. The proposed methodology was applied to 96 cocaine samples and 14 heroin samples seized in Galicia (northwestern Spain) within 2013 and 2014. PMID:27405875

  13. Sol-gel hybrid methyltrimethoxysilane-tetraethoxysilane as a new dispersive solid-phase extraction material for acrylamide determination in food with direct gas chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Omar, Mei Musa Ali; Wan Ibrahim, Wan Aini; Elbashir, Abdalla Ahmed

    2014-09-01

    A sol-gel hybrid sorbent, methyltrimethoxysilane-tetraethoxysilane (MTMOS-TEOS) was successfully used as new dispersive solid phase extraction (dSPE) sorbent material in the determination of acrylamide in several Sudanese foods and analysis using GC-MS. Several important dSPE parameters were optimised. Under the optimised conditions, excellent linearity (r(2)>0.9998) was achieved using matrix matched standard calibration in the concentration range 50-1000 μg kg(-1). The limits of detection (LOD) and limit of quantification ranged from 9.1 to 12.8 μg/kg and 27.8-38.9 μg/kg, respectively. The precision (RSD%) of the method was ⩽6.6% and recoveries of acrylamide obtained were in the range of 88-103%, (n=3). The LOD obtained is comparable with the LODs of primary secondary amine dSPE. The proposed MTMOS-TEOS dSPE method is direct and safe for acrylamide analysis, showed reliable method validation performances and good cleanup effects. It was successfully applied to the analysis of acrylamide in real food samples.

  14. Simultaneous analysis of non-steroidal anti-inflammatory drugs and estrogenic hormones in water and wastewater samples using gas chromatography-mass spectrometry and gas chromatography with electron capture detection

    Energy Technology Data Exchange (ETDEWEB)

    Migowska, Natalia; Caban, Magda; Stepnowski, Piotr; Kumirska, Jolanta, E-mail: kumirska@chem.univ.gda.pl

    2012-12-15

    Non-steroidal anti-inflammatory drugs are the group of pharmaceuticals that is most often found in the environment, whereas estrogenic hormones are considered to be potent endocrine disruptors. However, the fate and persistence of these compounds in the environment are still unclear. In this study we propose two approaches for determining these compounds in environmental water samples: GC-MS using time windows and operating in selected ion-monitoring mode (SIM) and, for the first time, gas chromatography with electron capture detection (GC-ECD). The identification criteria of both methods fulfilled the requirements of Directive 2002/657/EC. The use of time windows improved the sensitivity of GC-MS measurements. In GC-MS analysis the pharmaceuticals were determined as trimethylsilyl, in GC-ECD as pentafluoropropionyl derivatives. The influence of such parameters as the type of reagent, type of solvent, reaction time, reaction temperature and microwave irradiation in a household microwave oven on the efficacy of silylation was investigated. Derivatization using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and 1% trimethylchlorosilane (TMCS) in pyridine (1:1, v/v) for 30 min in 60 Degree-Sign C was found to be optimal. Optimization of the solid phase extraction procedure (SPE) confirmed that the application of Oasis HLB cartridges, the acidification of loading samples to pH 2 and the use of methanol as eluent gave the best absolute recoveries (ARs) of the target compounds. The following ARs of all the compounds were achieved: 58.2-106.8% in influent wastewater, 77.8-103.4% in effluent wastewater and 81.2-101.9% in surface water samples. Validation of the SPE-GC-MS method enables 13 pharmaceuticals to be determined with MDLs between 3.3 and 343.6 ng/L, depending on the analytes and matrices. GC-ECD analysis enables the determination of 6 pharmaceuticals in surface water samples with MDLs between 0.7 and 5.4 ng/L. The proposed methods were successfully used for

  15. Screening procedure for detection of non-steroidal anti-inflammatory drugs and their metabolites in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons by gas chromatography-mass spectrometry after extractive methylation.

    Science.gov (United States)

    Maurer, H H; Tauvel, F X; Kraemer, T

    2001-01-01

    Non-steroidal anti-inflammatory drugs (NSAIDs) are widely used as analgesic and anti-rheumatic drugs, and they are often misused. A gas chromatographic-mass spectrometric (GC-MS) screening procedure was developed for their detection in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons after extractive methylation. The compounds were separated by capillary GC and identified by computerized MS in the full-scan mode. Using mass chromatography with the ions m/z 119, 135, 139, 152, 165, 229, 244, 266, 272, and 326, the possible presence of NSAIDs and their metabolites could be indicated. The identity of positive signals in such mass chromatograms was confirmed by comparison of the peaks underlying full mass spectra with the reference spectra recorded during this study. This method allowed the detection of therapeutic concentrations of acemetacin, acetaminophen (paracetamol), acetylsalicylic acid, diclofenac, diflunisal, etodolac, fenbufen, fenoprofen, flufenamic acid, flurbiprofen, ibuprofen, indometacin, kebuzone, ketoprofen, lonazolac, meclofenamic acid, mefenamic acid, mofebutazone, naproxen, niflumic acid, phenylbutazone, suxibuzone, tiaprofenic acid, tolfenamic acid, and tolmetin in urine samples. The overall recoveries of the different NSAIDs ranged between 50 and 80% with coefficients of variation of less than 15% (n = 5), and the limits of detection of the different NSAIDs were between 10 and 50 ng/mL (S/N = 3) in the full-scan mode. Extractive methylation has proved to be a versatile method for STA of various acidic drugs, poisons, and their metabolites in urine. It has also successfully been used for plasma analysis.

  16. Determination of O6-butylguanine in DNA by immunoaffinity extraction/gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive, specific, and rapid method for quantitating the minor adduct O6-butylguanine (O6BuG) in hydrolyzed DNA has been developed by combining immunoaffinity chromatography and high resolution gas chromatography-negative ion chemical ionization-mass spectrometry. Polyclonal antibodies raised against O6BuG were coupled to CNBr-activated Sepharose 4B and used for sample clean-up and extraction of the specific O6-alkylguanine. After addition of O6BuG and its deuterium labeled analogue (O6BuG-D7), used as internal standard, hydrolyzed DNA was applied on the immunoaffinity column and washed with water, and the immunoadsorbed butylated guanines were eluted with acetone/water cetome/water (95/5) before gas chromatographic derivatization. O6BuG and O6BuG-D7 were analyzed and quantitated by high resolution gas chromatography-negative ion chemical ionization-mass spectrometry as their pentafluorobenzyl-trimethylsilyl derivatives. Immunoaffinity column capacity and O6BuG recovery from this column were 1.53 nmol O6BuG/column and 62 +/- 5%, respectively. The method was applied to evaluate O6BuG levels in DNA butylated in vitro with 10 mM N-nitroso-Nr-butylurea or isolated from rats given an i.p. dose of 185 mg/kg N-nitroso-N-butylurea or N-nitrosodibutylamine. In the first case the level of modifications present in calf thymus DNA was 104 mumol O6BuG/mol guanine, and in the second case O6BuG in liver DNA was about 6 times higher after N-nitroso-N-butylurea (2.11 mumol O6BuG/mol guanine) than after N-nitrosodibutylamine (0.34 mumol O6BuG/mol guanine) treatment. These results indicate that O6BuG formed in vivo can be isolated and quantitated by this method, which may also be useful for studying DNA damage and repair mechanisms

  17. Vinegar Metabolomics: An Explorative Study of Commercial Balsamic Vinegars Using Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Pinu, Farhana R.; de Carvalho-Silva, Samuel; Trovatti Uetanabaro, Ana Paula; Villas-Boas, Silas G.

    2016-01-01

    Balsamic vinegar is a popular food condiment produced from cooked grape must by two successive fermentation (anaerobic and aerobic) processes. Although many studies have been performed to determine the composition of major metabolites, including sugars and aroma compounds, no study has been undertaken yet to characterize the comprehensive metabolite composition of balsamic vinegars. Here, we present the first metabolomics study of commercial balsamic vinegars by gas chromatography coupled to mass spectrometry (GC-MS). The combination of three GC-MS methods allowed us to detect >1500 features in vinegar samples, of which 123 metabolites were accurately identified, including 25 amino acids, 26 carboxylic acids, 13 sugars and sugar alcohols, four fatty acids, one vitamin, one tripeptide and over 47 aroma compounds. Moreover, we identified for the first time in vinegar five volatile metabolites: acetin, 2-methylpyrazine, 2-acetyl-1-pyroline, 4-anisidine and 1,3-diacetoxypropane. Therefore, we demonstrated the capability of metabolomics for detecting and identifying large number of metabolites and some of them could be used to distinguish vinegar samples based on their origin and potentially quality. PMID:27455339

  18. Sensitive quantification of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hofmann, Ute; Schwab, Matthias; Treiber, Gerd; Klotz, Ulrich

    2006-02-01

    A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions. PMID:16338182

  19. Determination of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kanazawa, Hideko; Okada, Akiko; Matsushima, Yoshikazu; Yokota, Hiromitsu; Okubo, Shigeo; Mashige, Fumiko; Nakahara, Kazuhiko

    2002-03-01

    Omeprazole is a benzimidazole compound that acts as a proton-pump inhibitor. Because the metabolism of omeprazole is mainly catalyzed by cytochrome P-450 (CYP) 3A4 and CYP2C19. the genetic polymorphism of CYP2C19 could be of clinical concern in the treatment of acid-related diseases with omeprazole. Therefore, a reliable method for omeprazole phenotyping is desirable in clinical situations. This study has demonstrated the determination of omeprazole and its metabolites in human plasma by liquid chromatography-three-dimensional quadrupole mass spectrometry with a sonic spray ionization interface. The analytical column was YMC-Pack Pro C18(50x2.0 mm I.D.) using acetonitrile-50 mM ammonium acetate (pH 7.25) (1:4) at a flow-rate of 0.2 ml/min. The drift voltage was 30 V. The sampling aperture was heated at 110 degrees C and Shield temperature was 230 degrees C. In the mass spectrum, the molecular ions of omeprazole, hydroxyomeprazole and omeprazole sulfone were clearly observed as base peaks. This method is sufficiently sensitive and accurate for pharmacokinetic studies of omeprazol. PMID:11999727

  20. Determination of fenbendazole and oxfendazole in liver and muscle using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Blanchflower, W J; Cannavan, A; Kennedy, D G

    1994-06-01

    A method has been developed for the determination of the anthelmintics fenbendazole and oxfendazole in liver and muscle samples using liquid chromatography-thermospray mass spectrometry (LC-MS). The samples were homogenized with water, sonicated with methanol and centrifuged. The supernatants were washed with light petroleum and extracted with diethyl ether-ethyl acetate. The extracts were evaporated to dryness, dissolved in mobile phase and injected into the LC-MS system. Fenbendazole and oxfendazole were measured separately using two different mobile phases. Single-ion monitoring of the positive ion at m/z 300 was used for fenbendazole and of m/z 316 for oxfendazole. The detection limits for the assay were 0.05 microgram g-1 for fenbendazole and 0.1 microgram g-1 for oxfendazole. The mean recoveries were 91% for fenbendazole and 86% for oxfendazole. The assay has been used for statutory testing purposes and for measuring the levels of fenbendazole and oxfendazole in liver and muscle from sheep after dosing with a commercial anthelmintic containing fenbendazole.

  1. Structural investigations of neuromelanin by pyrolysis-gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Pyrolysis combined with gas chromatography and mass spectrometry (Py-GC/MS) was applied for structural investigations of the human substantia nigra neuromelanin. Using synthetic neuromelanins, we have demonstrated that Py-GC/MS is suitable for identification and differentiation of both eumelanin (dopamine-derived) and pheomelanin (cysteinyldopamine-derived) component of the pigment. Structural information on melanin monomers was inferred from their pyrolytic markers. When the human neuromelanin was subjected to pyrolysis, none of the heterocyclic, sulfur-containing markers of pheomelanin component was detected among the thermal degradation products. We have concluded that nigral pigment isolated from normal brain tissue does not contain benzothiazine-type monomers, and that cysteinyldopamine-originated units may be incorporated into the polymer in uncyclized form. The most abundant pyrolysis product was identified as limonene, which indicates that nigral pigment is tightly associated with an isoprenoid-type compound. Pyrolysis in the presence of the methylating reagent allowed identification of high levels of saturated and monounsaturated straight-chain C14-C18 fatty acid species chemically bound to the pigment macromolecule. (author)

  2. Simultaneous liquid chromatography-mass spectrometry quantification of cefixime and clavulanic acid in human plasma.

    Science.gov (United States)

    Dubala, Anil; Nagarajan, Janaki Sankarachari Krishnan; Vimal, Chandran Sathish; George, Renjith

    2015-01-01

    A simple and specific liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) assay method has been developed and fully validated for the simultaneous quantification of cefixime (CX) and clavulanic acid (CA) in human plasma. Analytes and internal standard were extracted from human plasma by a solid phase extraction technique using a Sam prep (3 mL, 100 mg) extraction cartridge. The extracted samples were chromatographed on a reverse phase C18 column using a mixture of methanol : acetonitrile : 2 mM ammonium acetate (pH 3.5) (25 : 25 : 50, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Quantification of the analytes were carried out using single quadrupole LC-APCI-MS through selected ion monitoring at m/z 452 and 198, respectively, for CX and CA. The assay was linear over the concentration range of 0.05-10.0 and 0.1-10.0 μg/mL, respectively, for CX and CA. The mean plasma extraction recoveries of the CX and CA were found to be 95.20-96.27% and 94.67-95.58%, respectively. The method was successfully applied for the determination of pharmacokinetics of CX and CA after oral administration of single dosage CX/CA (200/125 mg) pill to the humans (n = 12).

  3. Hydrocarbon phenotyping of algal species using pyrolysis-gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kothari Shankar L

    2010-05-01

    Full Text Available Abstract Background Biofuels derived from algae biomass and algae lipids might reduce dependence on fossil fuels. Existing analytical techniques need to facilitate rapid characterization of algal species by phenotyping hydrocarbon-related constituents. Results In this study, we compared the hydrocarbon rich algae Botryococcus braunii against the photoautotrophic model algae Chlamydomonas reinhardtii using pyrolysis-gas chromatography quadrupole mass spectrometry (pyGC-MS. Sequences of up to 48 dried samples can be analyzed using pyGC-MS in an automated manner without any sample preparation. Chromatograms of 30-min run times are sufficient to profile pyrolysis products from C8 to C40 carbon chain length. The freely available software tools AMDIS and SpectConnect enables straightforward data processing. In Botryococcus samples, we identified fatty acids, vitamins, sterols and fatty acid esters and several long chain hydrocarbons. The algae species C. reinhardtii, B. braunii race A and B. braunii race B were readily discriminated using their hydrocarbon phenotypes. Substructure annotation and spectral clustering yielded network graphs of similar components for visual overviews of abundant and minor constituents. Conclusion Pyrolysis-GC-MS facilitates large scale screening of hydrocarbon phenotypes for comparisons of strain differences in algae or impact of altered growth and nutrient conditions.

  4. Quantitative metabolomics based on gas chromatography mass spectrometry: Status and perspectives

    NARCIS (Netherlands)

    Koek, M.M.; Jellema, R.H.; Greef, J. van der; Tas, A.C.; Hankemeier, T.

    2011-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues (the metabolome). By analyzing differences between metabolomes using biostatistics (multivariate data analysis; pattern recognition), metabolites rele

  5. Coupled in-tube and on-fibre solid-phase microextractions for cleanup and preconcentration of organic micropollutants from aqueous samples and analysis by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gupta, Manju; Pillai, Aradhana K K V; Jain, Archana; Verma, Krishna K

    2008-06-16

    Matrix interference removal is an important step when large volumes of aqueous samples are required to be processed to detect trace levels of analytes. A combination of two sample extraction methods has been used in this work with the aim of cleanup and preconcentration of analytes. For first objective, mild but preferential sorption of a range of analytes has been performed with in-tube solid-phase microextraction (SPME) using polytetrafluoroethylene (PTFE) tubing, and for the second, the eluate from in-tube SPME was subjected to on-fibre SPME using DVB/Caboxen/PDMS (30/50 microm) fibre. Knitting of PTFE tubing created secondary flow pattern that enhanced radial diffusion and retention of organic analytes. Up to 2 mgL(-1) of a broad range of substances that are not extracted by PTFE include nitrogen containing aromatic heterocyclic compounds, anilines, phenols and certain organophosphorus pesticides, thus providing a clean extract using this method of sample preparation. The proposed combination of in-tube and on-fibre SPME produced a rectilinear calibration graph over 0.03-150 microgL(-1) of a range of analytes using 60 mL of aqueous sample. The overall recovery of analytes was in the range 27-78%. The detection limits were between 6.1 and 21.8 ngL(-1). The R.S.D. was in range 5.4-8.2% and 4.2-6.5% in the analysis of respectively 2 and 20 microgL(-1) of analytes. PMID:18501246

  6. Analysis of chemical constituents in waste gas pollutant of paint industry by gas chromatography-mass spectrometry and chemometrics resolution method%GC-MS法测定油漆行业废气化学成分及化学计量学解析

    Institute of Scientific and Technical Information of China (English)

    张斌

    2011-01-01

    A new method of analyzing the chemical constituents in waste gas polluta nt of paint was industry were introduced. Analysis of chemical constituents in waste gas pollutant of paint industry was performed with two dimensional gas chromatography-mass spectrometry (GC/MS) coupled with chemometrics resolution method (CRM). By means of these methods two-dimensional data, 49 chemical components in waste gas pollutant of paint industry were obtained from 25 chromatographic peaks and 40 compounds were determined qualitatively and quantitatively, amounting to 92.3% total contents of waste gas pollutant of paint industry. The main components in waste gas pollutant of paint industry were benzene series and alkane, amounting to 46. 8% and 27.2%,respectively.%采用GU/MS法分离测定油漆行业废气污染物化学成分,利用化学计量学解析法(CRM)对重叠的色谱峰进行解析,得到各成分的纯色谱曲线和质谱,通过质谱库对解析的纯组分进行定性,用解析色谱曲线积分法进行定量.从25个色谱峰中解析出了49个组分,按检索相似度大于90%的原则,鉴定出了其中40个化合物,占总含量的92.3%.废气污染物的主要成分为苯系物和烷烃,分别占总含量的46.8%和27.2%.

  7. Investigating the in vitro metabolism of fipexide: characterization of reactive metabolites using liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Sleno, Lekha; Staack, Roland F; Varesio, Emmanuel; Hopfgartner, Gérard

    2007-01-01

    The in vitro metabolism of the nootropic drug fipexide was studied using different liquid chromatography/mass spectrometry (LC/MS) techniques. This drug has been withdrawn from the market due to toxic effects. No previous reports have investigated the possible involvement of reactive metabolites in the toxicity of fipexide. The hydrolysis of this drug leads to the formation of two potentially toxic species, 3,4-methylenedioxybenzylpiperazine (MDBP) and 4-chlorophenoxyacetic acid (4-CPA). Here, we investigate the in vitro metabolism of fipexide in human, rat, mouse and dog, as well as of MDBP and 4-CPA in human and rat, while focusing on the formation of reactive metabolites. A combination of LC/MS analyses on a hybrid quadrupole-linear ion trap instrument and accurate mass data from QqTOF measurements was employed for the characterization of these metabolites. Microsomal metabolites of fipexide were MDBP, 4-CPA, fipexide N-oxide or hydroxyl, demethylenated fipexide and other minor ones, all of which were investigated by tandem mass spectrometry. Reactive metabolites were detected using several trapping procedures with small molecules such as glutathione, its ethyl ester derivative and N-acetylcysteine. The demethylenated metabolite, a catechol, formed its corresponding ortho-quinone, which readily reacts with these nucleophiles. MDBP was studied in a similar manner, due to its ability to form an analogous catechol. Because of its acidic nature, 4-CPA was assessed for possible acylglucuronide and acyl-CoA thioester metabolites, which could also be involved in bioactivation pathways. Several important metabolites were identified as potential mediators of toxicity via protein binding. PMID:17577876

  8. Quantitative liquid chromatography/mass spectrometry/mass spectrometry warfarin assay for in vitro cytochrome P450 studies.

    Science.gov (United States)

    Zhang, Z Y; King, B M; Wong, Y N

    2001-11-01

    A sensitive assay using high-performance liquid chromatography tandem mass spectrometry (MS/MS) has been established for the quantitative analysis of cytochrome P450 form-specific activities using warfarin as a probe substrate. Four metabolites, 6-, 7-, 8-, and 10-hydroxywarfarin, were chromatographically resolved within 10 min using gradient mobile phases. The mass spectrometry was operated under negative ionization mode. The MS/MS product ion spectra of warfarin and the metabolites were generated using collision-activated dissociation and interpreted. The abundant product ions of the metabolites were selected for quantification applying multiple reaction monitoring. Quantification was based on a quadratic or power curve of the peak area ratio of the metabolite over the internal standard against the respective concentration of the metabolite. This assay has been validated from 2 to 1000 nM for 10-hydroxywarfarin and from 2 to 5000 nM for 6-, 7-, and 8-hydroxywarfarin and successfully applied to evaluate cytochrome P450-mediated drug-drug interactions in vitro using human hepatocytes and liver microsomal preparations. PMID:11673893

  9. Analysis of benzene polycarboxylic acids and nitro-benzene polycarboxylic acids as molecular tracers of black carbon by using liquid chromatography-mass spectrometry%液相色谱-质谱法分析黑碳的分子标志物--苯多羧酸和硝基苯多羧酸

    Institute of Scientific and Technical Information of China (English)

    黄国培; 陈颖军; 田崇国; 刘莺

    2016-01-01

    苯多羧酸法是定量检测黑碳和溶解态黑碳的重要分子标志物法,其中苯多羧酸和硝基苯多羧酸的分离和定量是关键环节。本文建立了苯多羧酸和硝基苯多羧酸的液相色谱-质谱分析方法,利用质谱的定性能力解决了部分苯多羧酸和硝基苯多羧酸化合物在缺乏标准品情况下的定性问题。用 Phenomenex Synergi Polar RP 分离柱,柱温为35℃,流动相为0.5%(体积分数)甲酸水溶液和甲醇,流速为0.5 mL/min,梯度洗脱,以电喷雾离子源负离子全扫描和选择扫描模式进行离子阱质谱检测,同时利用串联的二极管阵列检测器采集三维紫外光谱数据。在实际样品检测中,14个含3个及以上羧基的苯多羧酸和硝基苯多羧酸化合物获得良好分离。此方法简化并加快了苯多羧酸法定量黑碳和溶解态黑碳的分析过程,可满足环境样品中黑碳和溶解态黑碳的分析,促进了苯多羧酸法应用的普及。%The benzene polycarboxylic acid( BPCA)method is an important molecular marker method for black carbon and dissolved black carbon quantification while the separation and quantification of benzene polycarboxylic acids and nitro-benzene polycarboxylic acids are the key process. In order to use mass spectrometer to solve the issue of identification of benzene polycarboxylic acids and nitro-benzene polycarboxylic acids due to the lack of the standards of some of the target compounds,a liquid chromatography-mass spectrometry method was pro-posed. It made the experimental procedures easier and faster than using the gas chromatogra-phy mass spectrometry,and would promote the use of the BPCA method. A Phenomenex Syn-ergi Polar RP column was used. The digestion productions of black carbon and dissolved black carbon were gradiently eluted by the mobile phases of 0. 5%( v/v)aqueous formic acid solution and methanol with the flow rate of 0. 5 mL/min at 35 ℃. The determination

  10. Ion and gas chromatography mass spectrometry investigations of organophosphates in lithium ion battery electrolytes by electrochemical aging at elevated cathode potentials

    Science.gov (United States)

    Weber, Waldemar; Wagner, Ralf; Streipert, Benjamin; Kraft, Vadim; Winter, Martin; Nowak, Sascha

    2016-02-01

    The electrochemical aging of commercial non-aqueous lithium hexafluorophosphate (LiPF6)/organic carbonate solvent based lithium ion battery electrolyte has been investigated in view of the formation of ionic and non-ionic alkylated phosphates. Subject was a solvent mixture of ethylene carbonate/ethyl methyl carbonate EC:EMC (1:1, by wt.) with 1 M LiPF6 (LP50 Selectilyte™, BASF). The analysis was carried out by ion chromatography coupled with electrospray ionization mass spectrometry (ESI-MS) for ionic compounds and (headspace) gas chromatography mass spectrometry ((HS)-GC-MS) for non-ionic compounds. The electrochemical aging was performed by galvanostatic charge/discharge cycling and potentiostatic experiments with LiNi0.5Mn1.5O4 (LMNO) as cathode material at increased cut-off potentials (>4.5 V vs. Li/Li+). A strong dependence of the formation of organophosphates on the applied electrode potential was observed and investigated by quantitative analysis of the formed phosphates. In addition, new possible "fingerprint" compounds for describing the electrolyte status were investigated and compared to existing compounds.

  11. Exploring symbiotic nitrogen fixation and assimilation in pea root nodules by in vivo 15N nuclear magnetic resonance spectroscopy and liquid chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Scharff, A.M.; Egsgaard, H.; Hansen, P.E.;

    2003-01-01

    Nitrogen (N) fixation and assimilation in pea (Pisum sativum) root nodules were studied by in vivo N-15 nuclear magnetic resonance (NMR) by exposing detached nodules to N-15, via a perfusion medium, while recording a time course of spectra. In vivo P-31 NMR spectroscopy was used to monitor...... the physiological state of the metabolically active nodules. The nodules were extracted after the NMR studies and analyzed for total soluble amino acid pools and N-15 labeling of individual amino acids by liquid chromatography-mass spectrometry. A substantial pool of free ammonium was observed by N-15 NMR...... labeling of Asn was observed by liquid chromatography-mass spectrometry, which is consistent with the generally accepted role of Asn as the end product of primary N assimilation in pea nodules. However, the Asn N-15 amino signal was absent in in vivo N-15 NMR spectra, which could be because...

  12. Atmospheric pressure photoionisation : An ionization method for liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Robb, DB; Covey, TR; Bruins, AP

    2000-01-01

    Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from a

  13. Field measurements of biogenic volatile organic compounds in the atmosphere by dynamic solid-phase microextraction and portable gas chromatography-mass spectrometry

    Science.gov (United States)

    Barreira, Luís Miguel Feijó; Parshintsev, Jevgeni; Kärkkäinen, Niina; Hartonen, Kari; Jussila, Matti; Kajos, Maija; Kulmala, Markku; Riekkola, Marja-Liisa

    2015-08-01

    Biogenic volatile organic compounds (BVOCs) participate in many physicochemical processes in the atmosphere. Studies indicate that some of these volatile compounds can be photo-oxidized to non-volatile species that contribute to atmospheric formation and growth of secondary organic aerosols (SOA). In this study, the applicability of dynamic solid-phase microextraction (SPME) for the sampling of atmospheric BVOCs and their oxidation products was tested. These compounds were then analysed via portable gas chromatography-mass spectrometry (GC-MS). The measurements were performed in mid-summer 2013 at the Station for Measuring Ecosystem-Atmosphere Relations, SMEAR II in Hyytiälä, Finland. Numerous classes of compounds were efficiently sampled on PDMS/DVB coated SPME, thermally desorbed and analysed by GC-MS, including monoterpenes, their oxidation products, and amines. Results were analysed against meteorological conditions observed during the sampling campaign and the total amount of monoterpenes obtained by proton-transfer-reaction mass spectrometry (PTR-MS). The comparison of the referred data with obtained results demonstrated the capability of the dynamic SPME method for fast in-situ sampling and analysis of organic gaseous compounds in the atmosphere with minimal analytical steps.

  14. Recent applications of liquid chromatography-mass spectrometry in natural products bioanalysis.

    Science.gov (United States)

    Xing, Jie; Xie, Chunfeng; Lou, Hongxiang

    2007-06-28

    Natural flavonoids, alkaloids, saponins and sesquiterpenoids have been extensively investigated because of their biological and physiological significances, as well as their promising clinical uses. It is necessary to monitor them or their metabolites in biological fluids for both pre-clinical studies and routine clinical uses. The successful hyphenation of LC and MS, which was thought as "the bird wants to marry with fish", has been conducted widely in biological samples analysis. This present paper reviewed the feasibility of LC-MS techniques in the identification and quantification of natural products (flavonoids, alkaloids, saponins and sesquiterpenoids) in biological fluids, dealing with sample preparation, LC techniques, suitability of different MS techniques. Perspective of LC-MS was also discussed to show the potential of this technology. The citations cover the period 2002-2006. We conclude that LC-MS is an extremely powerful tool for the analysis of natural products in biological samples. PMID:17317073

  15. Liquid Chromatography-Mass Spectrometry Interface for Detection of Extraterrestrial Organics

    Science.gov (United States)

    Southard, Adrian E.; Getty, Stephanie A.; Balvin, Manuel; Cook, Jamie E.; Espiritu, Ana Mellina; Kotecki, Carl; Towner, Deborah W.; Dworkin, J. P.; Glavin, Daniel P.; Mahaffy, Paul R.; Ferrance, J.

    2014-01-01

    The OASIS (Organics Analyzer for Sampling Icy surfaces) microchip enables electrospray or thermospray of analyte for subsequent analysis by the OASIS time-of-flight mass spectrometer. Electrospray of buffer solution containing the nucleobase adenine was performed using the microchip and detected by a commercial time-of-flight mass spectrometer. Future testing of thermospray and electrospray capability will be performed using a test fixture and vacuum chamber developed especially for optimization of ion spray at atmosphere and in low pressure environments.

  16. Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry

    OpenAIRE

    Cortada Cortés, Carolina; Costa dos Reis, Luciana; Vidal Martínez, Lorena; Llorca, Julio; Canals Hernández, Antonio

    2013-01-01

    A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was la...

  17. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine:Method validation and application to real samples

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    A fast screening protocol was developed for the simultaneous determination of nine antiestrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/ mass spectrometry (...

  18. Metabolomic profiling of human follicular fluid from patients with repeated failure of in vitro fertilization using gas chromatography/mass spectrometry

    OpenAIRE

    Xia, Lan; Zhao, Xiaoming; Sun, Yun; Hong, Yan; Gao, Yuping; Hu, Shuanggang

    2014-01-01

    Objective: To establish a gas chromatography/mass spectrometry (GC/MS)-based metabolomics method to compare the metabolites in the follicular fluid (FF) from patients with in vitro fertilization (IVF) and repeated IVF failure (RIF). Methods: A prospective study was employed in Center for Reprodutive Medcine, Renji Hospital, Shanghai, China, between January and October 2010. FF samples were collected from 13 patients with RIF and 15 patients who achieved pregnancy after the first IVF cycle. Re...

  19. A high expression EGFR/cell membrane chromatography and online high performance liquid chromatography/mass spectrometry method for screening EGFR antagonists from Rhizoma Polygoni Cuspidati

    OpenAIRE

    Meng Sun; Yan-min Zhang; Jie Zhang; Si-cen Wang; Lang-chong He

    2011-01-01

    The epidermal growth factor receptors (EGFRs) in some tumor cells are significant targets for drug discovery. In this work, we have developed an EGFR cell membrane chromatography and online high performance liquid chromatography/mass spectrometry system for screening active component from Rhizoma Polygoni Cuspidati. As a result, resveratrol from Rhizoma Polygoni Cuspidati was found to be the active component acting on EGFR like gefitinib. There was a good relationship between their inhibiting...

  20. Detection of chloramphenicol residue in bovine meat using Liquid Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Widiastuti R

    2014-03-01

    Full Text Available Chloramphenicol (CAP is a broad spectrum antibiotic that has been banned in many countries due to its serius side effect to human. Detection of CAP residue in food has been determined to a minimum required performance limit (MRPL of 0.3 ng/g. The purpose of this research was to conduct the analysis of CAP residue in bovine meat by using LCMS and to study the presence of CAP residue in marketed bovine meat samples. LC separation was done on a Shimpack column C18 with ammonium acetate 10 mM/water as mobile phase, and ESI-MS analysis in negative ion mode. The coefficient of determination, R2 = 0.9981 at concentration of 0.125, 0.25, 0.63, 1,00 and 2.00 ng/g. Recovery at three fortification levels (0.25, 0.50 and 1.00 ng/g was in the range 77.5, 97.3 and 83.4%. The decision limit and the detection capability were 0.15 ng/g and 0.17 ng/g respectively. Analysis results of 52 marketed samples showed that CAP residue were detected in 9 samples in the concentration range of 0.14 to 2.70 ng/g and 6 among those positive samples were above the MRPL value. Therefore, it is important to increase the awareness and also to monitor regularly CAP residues in food originated from animal to provide safe food for the consumers.

  1. Broad spectrum drug screening using electron-ionization gas chromatography-mass spectrometry (EI-GCMS).

    Science.gov (United States)

    Stone, Judy

    2010-01-01

    A liquid-liquid extraction (LLE) of drugs and internal standard (promazine) is performed by mixing urine at basic pH with 1-chlorobutane. There are no hydrolysis or derivatization steps. After centrifugation the organic (upper) layer is transferred to another tube and evaporated. The dried extract is reconstituted with ethyl acetate and 1 microL is injected onto the GCMS. Drugs are volatilized in the GC inlet and separated on a capillary column. In the EI source drugs become positively charged and fragment. Mass analysis of ionized fragments occurs with a single quadrupole. The resulting full scan mass spectra are automatically searched against three libraries. PMID:20077071

  2. Determination of 4-nitrocatechol in biodegradation samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zdráhal, Z

    1998-01-01

    4-Nitrocatechol was identified as a product of transformation of 4-nitrophenol by bacterial strain Corynebacterium sp.8/3 using direct acetylation of biodegradation samples by acetic anhydride followed by GC-MS analysis. The identity of 4-nitrocatechol, in the form of diacetate, was confirmed by electron-impact spectra and spectra recorded under chemical ionization conditions (positive and negative modes). Negative-ion chemical ionization was used for quantification of 4-nitrocatechol in biodegradation samples in a concentration range of 1-25 mg/l.

  3. New lysine-acetylated proteins screened by immunoaffinity and liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The lack of selective extraction specific for lysine-acetylated proteins has been a major problem in the field of acetylation biology,though acetylation plays a key role in many biological processes.In this paper,we report for the first time the proteomic screening of lysine-acetylated proteins from a mouse liver tissue,by a new approach of immunoaffinity purification of lysine-acetylated peptides combined with nano-HPLC/MS/MS analysis.We have found 20 lysine-acetylated proteins with 21 lysine-acetylated sites,among which 12 lysine-acetylated proteins and 16 lysine-acetylated sites have never been reported before.Notably,three acetyltransferases harboring in mitochondrion are newly discovered acetyltransferases responsible for the acetylation of nonhistone proteins.We have explored the significant patterns of residue preference by the hierarchical clustering analysis of amino acid residues surrounding acetylation sites,which could be helpful to the prediction of new sites of lysine acetylation.Our findings provide more candidates for studying the important roles played by acetylation in diverse cellular pathways and related human diseases.

  4. Improved sensitivity gas chromatography-mass spectrometry determination of parabens in waters using ionic liquids.

    Science.gov (United States)

    Cacho, Juan Ignacio; Campillo, Natalia; Viñas, Pilar; Hernández-Córdoba, Manuel

    2016-01-01

    A new procedure for the introduction of ionic liquid samples in gas chromatography (GC) is proposed. This procedure, based on microvial insert thermal desorption, allows the direct analysis of the compounds preconcentrated by ionic liquid based liquid-liquid microextraction (IL-LLME) using the combination of a thermal desorption unit (TDU) and a programmed temperature vaporization injector (PTV). Two different IL-LLME methodologies, one based on the formation of a microdroplet emulsion by dispersive liquid-liquid microextraction (DLLME) and other through ultrasound-assisted emulsification microextraction (USAEME) were studied and evaluated. IL-DLLME proved advantageous and consequently, it was adopted for preconcentration purposes. This easy to apply approach was used for the determination of five parabens (methyl-, ethyl-, propyl-, butyl- and isobutyl paraben) in swimming pool waters, after in situ acetylation. The optimized conditions of TDU/PTV allowed the analytes contained in 20 µL of the enriched IL to be transferred to the capillary column. Quantification of the samples was carried out against aqueous standards, and quantification limits of between 4.3 and 8.1 ng L(-1) were obtained, depending on the compound. Concentrations of between 9 and 47 ng L(-1) for some analytes were obtained in the analysis of ten samples. PMID:26695305

  5. Improving Liquid Chromatography-Mass Spectrometry Sensitivity Using a Subambient Pressure Ionization with Nanoelectrospray (SPIN) Interface

    Science.gov (United States)

    Tang, Keqi; Page, Jason S.; Marginean, Ioan; Kelly, Ryan T.; Smith, Richard D.

    2011-08-01

    In this work, the subambient pressure ionization with nanoelectrospray (SPIN) ion source and interface, which operates at ~15-30 Torr, is demonstrated to be compatible with gradient reversed-phase liquid chromatography-MS applications, exemplified here with the analysis of complex samples (a protein tryptic digest and a whole cell lysate). A low liquid chromatographic flow rate (100-400 nL/min) allowed stable electrospray to be established while avoiding electrical breakdown. Efforts to increase the operating pressure of the SPIN source relative to previously reported designs prevented solvent freezing and enhanced charged cluster/droplet desolvation. A 5- to 12-fold improvement in sensitivity relative to a conventional atmospheric pressure nanoelectrospray ionization (ESI) source was obtained for detected peptides.

  6. Comparative evaluation of preprocessing freeware on chromatography/mass spectrometry data for signature discovery.

    Science.gov (United States)

    Coble, Jamie B; Fraga, Carlos G

    2014-09-01

    Preprocessing software, which converts large instrumental data sets into a manageable format for data analysis, is crucial for the discovery of chemical signatures in metabolomics, chemical forensics, and other signature-focused disciplines. Here, four freely available and published preprocessing tools known as MetAlign, MZmine, SpectConnect, and XCMS were evaluated for impurity profiling using nominal mass GC/MS data and accurate mass LC/MS data. Both data sets were previously collected from the analysis of replicate samples from multiple stocks of a nerve-agent precursor and method blanks. Parameters were optimized for each of the four tools for the untargeted detection, matching, and cataloging of chromatographic peaks from impurities present in the stock samples. The peak table generated by each preprocessing tool was analyzed to determine the number of impurity components detected in all replicate samples per stock and absent in the method blanks. A cumulative set of impurity components was then generated using all available peak tables and used as a reference to calculate the percent of component detections for each tool, in which 100% indicated the detection of every known component present in a stock. For the nominal mass GC/MS data, MetAlign had the most component detections followed by MZmine, SpectConnect, and XCMS with detection percentages of 83, 60, 47, and 41%, respectively. For the accurate mass LC/MS data, the order was MetAlign, XCMS, and MZmine with detection percentages of 80, 45, and 35%, respectively. SpectConnect did not function for the accurate mass LC/MS data. Larger detection percentages were obtained by combining the top performer with at least one of the other tools such as 96% by combining MetAlign with MZmine for the GC/MS data and 93% by combining MetAlign with XCMS for the LC/MS data. In terms of quantitative performance, the reported peak intensities from each tool had averaged absolute biases (relative to peak intensities obtained

  7. Cinnamaldehyde content in foods determined by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Friedman, M; Kozukue, N; Harden, L A

    2000-11-01

    trans-Cinnamaldehyde, the principal component of cinnamon flavor, is a potent antimicrobial compound present in essential oils such as cinnamon. In the course of studies designed to discover its maximum microbial lethality under food-processing conditions, a gas chromatographic-mass spectrophotometric procedure was developed for the extraction and analysis of essential oil components such as cinnamaldehyde from commercial cinnamon-containing foods (several brands of cinnamon breads, cereals, cookies, puddings, applesauces, and fruit juices). The cinnamaldehyde content ranged from trace amounts in orange juice to 12.2 mg/100 g (122 ppm) in apple cinnamon cereals and 31.1 mg/100 g (311 ppm) for cinnamon swirl bread (highest value). To ascertain the heat stability of cinnamaldehyde, pure cinnamaldehyde, pure eugenol, cinnamon oil, and mixtures consisting of cinnamaldehyde plus eugenol or cinnamon oil were heated at graded temperatures up to 210 degrees C and 60 min, and then possible compositional changes were examined. Eugenol was stable to heat, as were the components of cinnamon oil: carvone, eugenol, and linalool. In contrast, starting at approximately 60 degrees C, pure cinnamaldehyde undergoes a temperature-dependent transformation to benzaldehyde under the influence of heat. Eugenol, both pure and in cinnamon oil, when added to pure cinnamaldehyde protected the aldehyde against heat destruction. The protection may due to an antioxidative action of eugenol. The possible mechanism of this effect and the significance of these findings for food chemistry and microbiology are discussed. PMID:11087542

  8. Integration of Gas Chromatography Mass Spectrometry Methods for Differentiating Ricin Preparation Methods

    Energy Technology Data Exchange (ETDEWEB)

    Wunschel, David S.; Melville, Angela M.; Ehrhardt, Christopher J.; Colburn, Heather A.; Victry, Kristin D.; Antolick, Kathryn C.; Wahl, Jon H.; Wahl, Karen L.

    2012-05-17

    The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of the castor plant Ricinus communis. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatographic - mass spectrometric (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method and independent of the seed source. In particular the abundance of mannose, arabinose, fucose, ricinoleic acid and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation.

  9. Confirmation of patulin and 5-hydroxymethylfurfural in apple juice by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Rupp, H S; Turnipseed, S B

    2000-01-01

    A gas chromatographic/mass spectrometric (GC/MS) method was developed for the confirmation of patulin and 5-hydroxymethylfurfural (HMF) extracted from apple juice. The extraction is based on the official AOAC method for liquid chromatographic analysis. Juice extracts are quickly and easily derivatized with bis(trimethylsilyl)trifluoracetamide under mild conditions, and the trimethylsilyl ethers of the analytes are stable for at least several hours. The analytes are determined by GC/MS using an electron-impact source and selected ion monitoring of characteristic ions. For both analytes, the interassay differences between base-peak ratios for samples and standards were all <7.1% (absolute). The presence of patulin was confirmed at fortification levels of about 30-400 microg/L and naturally occurring levels of about 80-400 microg/L. The presence of HMF was also confirmed at levels < or = 2 mg/L. The proposed mass spectral fragmentation pathways of the analytes are presented. PMID:10868584

  10. Chromatographic behaviour of steroidal saponins studied by high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kite, Geoffrey C; Porter, Elaine A; Simmonds, Monique S J

    2007-05-01

    The chromatographic behaviour of steroidal saponins found in Anemarrhena asphodeloides, Asparagus officinalis, Convallaria majalis, Digitalis purpurea and Ruscus aculeatus was studied by HPLC-MS using a C-18 reversed-phase column and aqueous acetonitrile or aqueous methanol mobile phase gradients, with or without the addition of 1% acetic acid. The behaviour was compared to that of triterpene saponins found in Aesculus hippocastanum, Centella asiatica, Panax notoginseng and Potentilla tormentilla. Inclusion of methanol in the mobile phase under acidic conditions was found to cause furostanol saponins hydroxylated at C-22 to chromatograph as broad peaks, whereas the peak shapes of the spirostanol saponins and triterpene saponins studied remained acceptable. In aqueous methanol mobile phases without the addition of acid, furostanol saponins chromatographed with good peak shape, but each C-22 hydroxylated furostanol saponin was accompanied by a second chromatographic peak identified as its C-22 methyl ether. Methanolic extracts analysed in non-acidified aqueous acetonitrile mobile phases also resolved pairs of C-22 hydroxy and C-22 methoxy furostanol saponins. The C-22 methyl ether of deglucoruscoside was found to convert to deglucoruscoside during chromatography in acidified aqueous acetonitrile, or by dissolving in water. Poor chromatography of furostanol saponins in acidified aqueous methanol is due to the interconversion of the C-22 hydroxy and C-22 methoxy forms. It is recommended that initial analysis of saponins by HPLC-MS using a C-18 stationary phase is performed using acidified aqueous acetonitrile mobile phase gradients. The existence of naturally-occurring furostanol saponins methoxylated at C-22 can be investigated with aqueous acetonitrile mobile phases and avoiding methanol in the extraction solvent. PMID:17391684

  11. Constituents of the essential oil from different brands of Syzigium caryophyllatum L by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Mohammad Amzad Hossain; Roudha Ali Al-Hashmi; Afaf Mohammed Weli; Qasim Al-Riyami; Jamal Nasser Al-Sabahib

    2012-01-01

    Objective: The aim of this present study was to isolate and analyze the chemical composition of essential oils from two different imported brands of Syzigium caryophyllatum (clove) samples using gas chromatography-mass spectrometry (GC-MS). Methods: The two essential oils were isolated by hydrodistillation from two different brands of Syzigium caryophyllatum (clove) such as Guzal and Shahi clove samples using Clevenger type apparatus. Results: Eleven chemical components were identified in the essential oil isolated from Guzal clove imported from Indonesia. The isolated components representing 99.03% of the Guzal clove oil were identified as eugenol (51.51%), caryophyllene (36.20%), α- caryophyllene (4.26%), acetyleugenol (2.64%), carvacrol (2.42%), α-cubebene (0.77%) and thymol (0.42%) were the major components with some other minor components isolated from the same. About twenty two components representing 99.73% were identified within the essential oil isolated from the Shahi brand clove which was imported from India with the main components being eugenol (46.53%), caryophyllene (43.03%),α-caryophyllene (4.61%), aceteugenol (2.54%), copaene (0.80%), α-farnesene (0.72%), germacrene (0.43%) and δ-cadinene (0.27%). Conclusions: Both the isolated essential oils were found to be rich in eugenol and caryophyllene. The clove essential oil from Guzal and Shahi was found to be comparable in terms of its eugenol and caryophyllene contents. According to the above findings, it is suggested that both brands of clove are of similar quality.

  12. Estimation of D-Arabinose by Gas Chromatography/Mass Spectrometry as Surrogate for Mycobacterial Lipoarabinomannan in Human Urine.

    Directory of Open Access Journals (Sweden)

    Prithwiraj De

    Full Text Available Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb, in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10-40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis.

  13. Assessing gibberellins oxidase activity by anion exchange/hydrophobic polymer monolithic capillary liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Ming-Luan; Su, Xin; Xiong, Wei; Liu, Jiu-Feng; Wu, Yan; Feng, Yu-Qi; Yuan, Bi-Feng

    2013-01-01

    Bioactive gibberellins (GAs) play a key regulatory role in plant growth and development. In the biosynthesis of GAs, GA3-oxidase catalyzes the final step to produce bioactive GAs. Thus, the evaluation of GA3-oxidase activity is critical for elucidating the regulation mechanism of plant growth controlled by GAs. However, assessing catalytic activity of endogenous GA3-oxidase remains challenging. In the current study, we developed a capillary liquid chromatography--mass spectrometry (cLC-MS) method for the sensitive assay of in-vitro recombinant or endogenous GA3-oxidase by analyzing the catalytic substrates and products of GA3-oxidase (GA1, GA4, GA9, GA20). An anion exchange/hydrophobic poly([2-(methacryloyloxy)ethyl]trimethylammonium-co-divinylbenzene-co-ethylene glycol dimethacrylate)(META-co-DVB-co-EDMA) monolithic column was successfully prepared for the separation of all target GAs. The limits of detection (LODs, Signal/Noise = 3) of GAs were in the range of 0.62-0.90 fmol. We determined the kinetic parameters (K m) of recombinant GA3-oxidase in Escherichia coli (E. coli) cell lysates, which is consistent with previous reports. Furthermore, by using isotope labeled substrates, we successfully evaluated the activity of endogenous GA3-oxidase that converts GA9 to GA4 in four types of plant samples, which is, to the best of our knowledge, the first report for the quantification of the activity of endogenous GA3-oxidase in plant. Taken together, the method developed here provides a good solution for the evaluation of endogenous GA3-oxidase activity in plant, which may promote the in-depth study of the growth regulation mechanism governed by GAs in plant physiology. PMID:23922762

  14. Assessing gibberellins oxidase activity by anion exchange/hydrophobic polymer monolithic capillary liquid chromatography-mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Ming-Luan Chen

    Full Text Available Bioactive gibberellins (GAs play a key regulatory role in plant growth and development. In the biosynthesis of GAs, GA3-oxidase catalyzes the final step to produce bioactive GAs. Thus, the evaluation of GA3-oxidase activity is critical for elucidating the regulation mechanism of plant growth controlled by GAs. However, assessing catalytic activity of endogenous GA3-oxidase remains challenging. In the current study, we developed a capillary liquid chromatography--mass spectrometry (cLC-MS method for the sensitive assay of in-vitro recombinant or endogenous GA3-oxidase by analyzing the catalytic substrates and products of GA3-oxidase (GA1, GA4, GA9, GA20. An anion exchange/hydrophobic poly([2-(methacryloyloxyethyl]trimethylammonium-co-divinylbenzene-co-ethylene glycol dimethacrylate(META-co-DVB-co-EDMA monolithic column was successfully prepared for the separation of all target GAs. The limits of detection (LODs, Signal/Noise = 3 of GAs were in the range of 0.62-0.90 fmol. We determined the kinetic parameters (K m of recombinant GA3-oxidase in Escherichia coli (E. coli cell lysates, which is consistent with previous reports. Furthermore, by using isotope labeled substrates, we successfully evaluated the activity of endogenous GA3-oxidase that converts GA9 to GA4 in four types of plant samples, which is, to the best of our knowledge, the first report for the quantification of the activity of endogenous GA3-oxidase in plant. Taken together, the method developed here provides a good solution for the evaluation of endogenous GA3-oxidase activity in plant, which may promote the in-depth study of the growth regulation mechanism governed by GAs in plant physiology.

  15. A Search for Amino Acids and Nucleobases in the Martian Meteorite Roberts Massif 04262 Using Liquid Chromatography-Mass Spectrometry

    Science.gov (United States)

    Callahan, Michael P.; Burton, Aaron S.; Elsila, Jamie E.; Baker, Eleni M.; Smith, Karen E.; Glavin, Daniel P.; Dworkin, Jason P.

    2013-01-01

    The investigation into whether Mars contains signatures of past or present life is of great interest to science and society. Amino acids and nucleobases are compounds that are essential for all known life on Earth and are excellent target molecules in the search for potential Martian biomarkers or prebiotic chemistry. Martian meteorites represent the only samples from Mars that can be studied directly in the laboratory on Earth. Here, we analyzed the amino acid and nucleobase content of the shergottite Roberts Massif (RBT) 04262 using liquid chromatography-mass spectrometry. We did not detect any nucleobases above our detection limit in formic acid extracts; however, we did measure a suite of protein and nonprotein amino acids in hot-water extracts with high relative abundances of beta-alanine and gamma-amino-eta-butyric acid. The presence of only low (to absent) levels of several proteinogenic amino acids and a lack of nucleobases suggest that this meteorite fragment is fairly uncontaminated with respect to these common biological compounds. The distribution of straight-chained amine-terminal eta-omega-amino acids in RBT 04262 resembled those previously measured in thermally altered carbonaceous meteorites. A carbon isotope ratio of -24(0/00) +/- 6(0/00) for beta-alanine in RBT 04262 is in the range of reduced organic carbon previously measured in Martian meteorites (Steele et al. 2012). The presence of eta-omega-amino acids may be due to a high temperature Fischer-Tropschtype synthesis during igneous processing on Mars or impact ejection of the meteorites from Mars, but more experimental data are needed to support these hypotheses.

  16. Comparative Evaluation of Preprocessing Freeware on Chromatography/Mass Spectrometry Data for Signature Discovery

    Energy Technology Data Exchange (ETDEWEB)

    Coble, Jamie B.; Fraga, Carlos G.

    2014-07-07

    Preprocessing software is crucial for the discovery of chemical signatures in metabolomics, chemical forensics, and other signature-focused disciplines that involve analyzing large data sets from chemical instruments. Here, four freely available and published preprocessing tools known as metAlign, MZmine, SpectConnect, and XCMS were evaluated for impurity profiling using nominal mass GC/MS data and accurate mass LC/MS data. Both data sets were previously collected from the analysis of replicate samples from multiple stocks of a nerve-agent precursor. Each of the four tools had their parameters set for the untargeted detection of chromatographic peaks from impurities present in the stocks. The peak table generated by each preprocessing tool was analyzed to determine the number of impurity components detected in all replicate samples per stock. A cumulative set of impurity components was then generated using all available peak tables and used as a reference to calculate the percent of component detections for each tool, in which 100% indicated the detection of every component. For the nominal mass GC/MS data, metAlign performed the best followed by MZmine, SpectConnect, and XCMS with detection percentages of 83, 60, 47, and 42%, respectively. For the accurate mass LC/MS data, the order was metAlign, XCMS, and MZmine with detection percentages of 80, 45, and 35%, respectively. SpectConnect did not function for the accurate mass LC/MS data. Larger detection percentages were obtained by combining the top performer with at least one of the other tools such as 96% by combining metAlign with MZmine for the GC/MS data and 93% by combining metAlign with XCMS for the LC/MS data. In terms of quantitative performance, the reported peak intensities had average absolute biases of 41, 4.4, 1.3 and 1.3% for SpectConnect, metAlign, XCMS, and MZmine, respectively, for the GC/MS data. For the LC/MS data, the average absolute biases were 22, 4.5, and 3.1% for metAlign, MZmine, and XCMS

  17. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    Science.gov (United States)

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-01

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  18. Usefulness of pyrolysis coupled to gas chromatography/mass spectrometry for evaluating the reproducibility of commercial samples of Cymbopogon citratus Stapf., Poaceae

    Directory of Open Access Journals (Sweden)

    Eduardo J. Oliveira

    2010-03-01

    Full Text Available The usefulness of pyrolysis coupled to gas chromatography/mass spectrometry (Py-GC/MS to evaluate the identity and reproducibility of different brands and batches of commercially available samples of Cymbopogon citratus Stapf (sold as tea was investigated. Samples of the vegetable material were extracted using hexane and the extract was pyrolysed at 450 ºC using a vertical microfurnace pyrolyser interfaced directly with a gas chromatograph/mass spectrometer operated using electron impact ionization at 70 eV. The relative peak areas of the different compounds identified on the pyrograms were used for multivariate data analysis using principal component analysis (PCA and hierarchical cluster analysis (HCA techniques. Principal component analysis of pyrolysis data from samples of different brands was able to represent 84.7% of the total variability within the first two principal components, and led to the correct classification of the samples tested. The method was also able to reveal important differences between samples when different batches of the same brand were compared.

  19. Simultaneous determination of amoxicillin and clavulanic acid in the human plasma by high performance liquid chromatography: Mass spectrometry (UPLC/MS

    Directory of Open Access Journals (Sweden)

    Ćirić Biljana

    2010-01-01

    Full Text Available Background/Aim. Quantitative analysis of amoxicillin and clavulanic acid in biological matrices requires sensitive and specific methods which allow determination of therapeutic concentration in μg/mL range. Analytical methods for determination of their concentrations in body fluids described in literature include high performance liquid chromatography coupled to UV detector (HPLC-UV and liquid chromatography-mass spectrometry (LC-MS. The aim of this study was to develop sensitive and specific ultra performance liquid chromatography/ mass spectrometry (UPLC/MS method which could be used for the spectral identification and quantification of the low concentrations of amoxicillin and clavulanic acid in the human plasma. Method. A sensitive and specific UPLC/MS method for amoxicillin and clavulanic acid determination was developed in this study. The samples were taken from the adult healthy volunteers receiving per os one tablet of amoxicillin (875 mg in combination with clavulanic acid (125 mg. Results. Plasma samples were pretreated by direct deproteinization with perchloric acid. Quantification limit of 0.01 μg/ml for both amoxicillin and clavulanic acid was achieved. The method was reproducible day by day (RSD < 7 %. Analytical recoveries for amoxicillin ranged from 98.82% to 100.9% (for concentrations of 1, 5 and 20 μg/mL, and recoveries for clavulanic acid were 99,89% to 100.1% (for concentrations of 1, 2 and 5 μg/mL. This assay was successfully applied to a pilot pharmacokinetic study in healthy volunteers after a single-oral administration of amoxicillin/ clavulanic combination. The determined plasma concentrations of both amoxicillin and clavulanic acid were in the range of the expected values upon the literature data for HPLC-UV and LC-MS methods. Conclusion. The described method provided a few advantages comparing with LC/MS-MS method. The method is faster using running time of 5 minute, has lower limit of quantification (LOQ and it

  20. Determination of chlorophenols in landfill leachate using headspace sampling with ionic liquid-coated solid-phase microextraction fibers combined with gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Tse-Tsung; Chen, Chung-Yu [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China); Li Zuguang [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China); College of Chemical Engineering and Materials Science, Zhejiang University of Technology, Hangzhou 310014, Zhejiang (China); Yang, Thomas Ching-Cherng [Department of Chemistry, National Kaohsiung Normal University, Kaohsiung 82444, Taiwan (China); Lee, Maw-Rong, E-mail: mrlee@dragon.nchu.edu.tw [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China)

    2012-01-27

    Highlights: Black-Right-Pointing-Pointer Ionic liquid (IL), ([C{sub 4}MIM][PF{sub 6}]), was rapid synthesized by microwave radiation. Black-Right-Pointing-Pointer Trace chlorophenols in landfill leachate were extract by SPME coated IL. Black-Right-Pointing-Pointer The IL-coated SPME-GC/MS method is low-cost, solvent-free and sensitive. - Abstract: A new microextraction technique based on ionic liquid solid-phase microextraction (IL-SPME) was developed for determination of trace chlorophenols (CPs) in landfill leachate. The synthesized ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C{sub 4}MIM][PF{sub 6}]), was coated onto the spent fiber of SPME for extraction of trace CPs. After extraction, the absorbed analytes were desorbed and quantified using gas chromatography-mass spectrometry (GC/MS). The term of the proposed method is as ionic liquid-coated of solid-phase microextraction combined with gas chromatography-mass spectrometry (IL-SPME-GC/MS). No carryover effect was found, and every laboratory-made ionic liquids-coated-fiber could be used for extraction at least eighty times without degradation of efficiency. The chlorophenols studied were 2,4-dichlorophenol (2,4-DP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and pentachlorophenol (PCP). The best results of chlorophenols analysis were obtained with landfill leachate at pH 2, headspace extraction for 4 min, and thermal desorption with the gas chromatograph injector at 240 Degree-Sign C for 4 min. Linearity was observed from 0.1 to 1000 {mu}g L{sup -1} with relative standard deviations (RSD) less than 7% and recoveries were over 87%. The limit of detection (LOD) for pentachlorophenol was 0.008 {mu}g L{sup -1}. The proposed method was tested by analyzing landfill leachate from a sewage farm. The concentrations of chlorophenols were detected to range from 1.1 to 1.4 {mu}g L{sup -1}. The results demonstrate that the IL-SPME-GC/MS method is highly effective in

  1. An in situ derivatization - dispersive liquid-liquid microextraction combined with gas-chromatography - mass spectrometry for determining biogenic amines in home-made fermented alcoholic drinks.

    Science.gov (United States)

    Płotka-Wasylka, Justyna; Simeonov, Vasil; Namieśnik, Jacek

    2016-07-01

    A novel dispersive liquid-liquid microextraction (DLLME) gas chromatography mass-spectrometry (GC-MS) method was developed for the determination of 13 biogenic amines in home-made wine samples. The method allows to simultaneous extraction and derivatization of the amines providing a simple and fast mode of extract enrichment. During the study, two different procedures were examined. Statistical analysis was performed to choose better procedure, as well as the conditions of derivatization reaction. At least, a mixture of methanol (dispersive solvent; 215μL), chloroform (extractive solvent; 400μL), and isobutyl choloroformate (derivatizing reagent; 90μL) was used as extractive/derivatizing reagent, added to 5mL of sample. The addition of mixture of pyridine and HCl was necessary to eliminate the by-products. The proposed method showed good linearity (correlation coefficients >0.9961), good recoveries (from 77 to 105%), and good intra-day precision (below 13%) and inter-day precision (below 10%). Moreover, detection limits were never over 4.1μg/L. The developed method was successfully applied to the analysis of 17 home-made wine samples not regulated by law. All of the biogenic amines analyzed were found in most of the wines.

  2. Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cortada, Carol; dos Reis, Luciana Costa; Vidal, Lorena; Llorca, Julio; Canals, Antonio

    2014-03-01

    A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L(-1). Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71 and 116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples. PMID:24468359

  3. Studies on the human metabolism and the toxicologic detection of the cough suppressant dropropizine in urine using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Staack, Roland F; Theobald, Denis S; Maurer, Hans H

    2004-08-01

    Studies are described on the metabolism and the toxicologic analysis of the nonopioid cough suppressant dropropizine [R,S-3-(4-phenyl-1-piperazinyl)1,2-propandiol, DRO] in human urine using gas chromatography-mass spectrometry (GC-MS). The metabolism studies showed that DRO was metabolized in humans mainly by hydroxylation of the aromatic ring, by N-dealkylation of the parent drug and of the hydroxyl-metabolite to the corresponding N-phenylpiperazines, and by degradation of the piperazine moiety. The authors' systematic toxicologic analysis (STA) procedure using full-scan GC-MS after acid hydrolysis, liquid-liquid extraction, and microwave-assisted acetylation allowed the unambiguous detection of DRO and its above-mentioned metabolites in human urine up to about 32 hours after intake of a single common therapeutic dose. The target analytes were found to be the parent compound DRO (earlier phase of excretion) and the hydroxylated metabolite para-hydroxy-DRO (later phase of excretion). Both allowed unambiguous detection of an intake of DRO and also differentiation from other phenylpiperazine derivatives. PMID:15257075

  4. Identification of resinous materials on 16th and 17th century reverse-glass objects by gas chromatography/mass spectrometry

    Science.gov (United States)

    Baumer, Ursula; Dietemann, Patrick; Koller, Johann

    2009-07-01

    Objects of hinterglasmalerei, reverse-glass paintings, are painted on the back side of glass panels. Obviously, the paint layers are applied in reverse order, starting with the uppermost layer. The finished hinterglas painting is viewed through the glass, thus revealing an impressive gloss and depth of colour. The binding media of two precious objects of hinterglasmalerei from the 16th and 17th century have been identified as almost exclusively resinous. Identification was performed by a special optimised analysis procedure, which is discussed in this paper: solvent extracts are analysed by gas chromatography/mass spectrometry, both with and without derivatisation or hydrolysis. In an additional step, oxalic acid is added to the methanol extracts prior to injection. This attenuates the peaks of the non-acidic compounds, whereas the acids elute with good resolution. The non-acidic compounds are emphasised after injection of the underivatised extracts. This approach minimises compositional changes caused by the sample preparation and derivatisation steps. Chromatograms of aged samples with a very complex composition are simplified, which allows a more reliable and straightforward identification of significant markers for various materials. The binding media of the hinterglas objects were thus shown to consist of mixtures of different natural resins, larch turpentine, heat-treated Pinaceae resin or mastic. Typical compounds of dragon's blood, a natural red resin, were also detectable in red glazes by the applied analysis routine. Identification of the binding media provides valuable information that can be used in the development of an adequate conservation treatment.

  5. A novel quantitation approach for maximizing detectable targets for offensive/volatile odorants with diverse functional groups by thermal desorption-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2016-01-01

    A multitude of analytical systems are needed to analyze diverse odorants with various functionalities. In this study, an experimental method was developed to assess the maximum covering range of odorants using a single experimental setup consisting of a thermal desorber-gas chromatography-mass spectrometry system. To this end, a total of 20 offensive odorants (aldehyde, ketone, ester, alcohol, aromatic, sulfide, amine, and carboxyl) were selected and tested by a single system. The analytical results of standards and environmental samples were evaluated in a number of respects. In the analysis of the standards, all targets were quantified via Carbopack (C + B + X) tube sampling while operating the thermal desorber at -25 °C. The method detection limits of 18 targets (exception of 2 out of the 20 targets: acetaldehyde and methanethiol) were excellent (mean 0.04 ± 0.03 ppb) in terms of their odor threshold values (74.7 ± 140 ~ 624 ± 1,729 ppb). The analysis of organic fertilizer plant samples at a pig farm (slurry treatment facility, compost facility, and ambient air) confirmed the presence of 18 odorants from 0.03 ppb (dimethyldisulfide, ambient sample) to 522 ppb (methyl ethyl ketone, slurry treatment facility). As such, our method allowed simultaneous quantitation of most key odorants with sufficient reliability and sensitivity. PMID:27404037

  6. An evaluation of liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization for the rapid and simultaneous measurement of carbamate pesticides and organophorus pesticides

    International Nuclear Information System (INIS)

    Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 μg/mL. The peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to tun. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng

  7. An in situ derivatization - dispersive liquid-liquid microextraction combined with gas-chromatography - mass spectrometry for determining biogenic amines in home-made fermented alcoholic drinks.

    Science.gov (United States)

    Płotka-Wasylka, Justyna; Simeonov, Vasil; Namieśnik, Jacek

    2016-07-01

    A novel dispersive liquid-liquid microextraction (DLLME) gas chromatography mass-spectrometry (GC-MS) method was developed for the determination of 13 biogenic amines in home-made wine samples. The method allows to simultaneous extraction and derivatization of the amines providing a simple and fast mode of extract enrichment. During the study, two different procedures were examined. Statistical analysis was performed to choose better procedure, as well as the conditions of derivatization reaction. At least, a mixture of methanol (dispersive solvent; 215μL), chloroform (extractive solvent; 400μL), and isobutyl choloroformate (derivatizing reagent; 90μL) was used as extractive/derivatizing reagent, added to 5mL of sample. The addition of mixture of pyridine and HCl was necessary to eliminate the by-products. The proposed method showed good linearity (correlation coefficients >0.9961), good recoveries (from 77 to 105%), and good intra-day precision (below 13%) and inter-day precision (below 10%). Moreover, detection limits were never over 4.1μg/L. The developed method was successfully applied to the analysis of 17 home-made wine samples not regulated by law. All of the biogenic amines analyzed were found in most of the wines. PMID:27237593

  8. A novel quantitation approach for maximizing detectable targets for offensive/volatile odorants with diverse functional groups by thermal desorption-gas chromatography-mass spectrometry

    Science.gov (United States)

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2016-07-01

    A multitude of analytical systems are needed to analyze diverse odorants with various functionalities. In this study, an experimental method was developed to assess the maximum covering range of odorants using a single experimental setup consisting of a thermal desorber-gas chromatography-mass spectrometry system. To this end, a total of 20 offensive odorants (aldehyde, ketone, ester, alcohol, aromatic, sulfide, amine, and carboxyl) were selected and tested by a single system. The analytical results of standards and environmental samples were evaluated in a number of respects. In the analysis of the standards, all targets were quantified via Carbopack (C + B + X) tube sampling while operating the thermal desorber at -25 °C. The method detection limits of 18 targets (exception of 2 out of the 20 targets: acetaldehyde and methanethiol) were excellent (mean 0.04 ± 0.03 ppb) in terms of their odor threshold values (74.7 ± 140 ~ 624 ± 1,729 ppb). The analysis of organic fertilizer plant samples at a pig farm (slurry treatment facility, compost facility, and ambient air) confirmed the presence of 18 odorants from 0.03 ppb (dimethyldisulfide, ambient sample) to 522 ppb (methyl ethyl ketone, slurry treatment facility). As such, our method allowed simultaneous quantitation of most key odorants with sufficient reliability and sensitivity.

  9. Identification of chemical constituents in two traditional Chinese medicine formulae by liquid chromatography-mass spectrometry and off-line nuclear magnetic resonance.

    Science.gov (United States)

    Wang, Shufang; Zhu, Yunxiang; Shao, Qing; Wang, Yi; Fan, Xiaohui; Cheng, Yiyu

    2016-01-01

    There have been increasing works on identification of the chemical constituents in traditional Chinese medicines (TCMs) by liquid chromatography-mass spectrometry (LC-MS). However, isomers cannot be distinguished generally only by MS data, and the structures of unknown compounds cannot be confirmed. In this study, semi-preparative LC guided by LC-MS was used to prepare the isomers in microscale followed by off-line NMR analysis to confirm their structures. This approach was applied to identifying the constituents in two TCM formulae, Zhi-Zi-Gan-Cao-Chi-Tang (ZZGCCT) and Zhi-Zi-Bai-Pi-Tang (ZZBPT). A total number of 119 constituents were identified tentatively or unambiguously by LC-IT-MS, LC-Q-TOF-MS, and NMR. Among them, 20 constituents were characterized unambiguously by comparing with the reference substances. In addition, 21 constituents without reference substances were prepared for the following 1D-NMR and/or 2D-NMR analysis, and their structures were unambiguously identified by MS, 1D-NMR, and 2D-NMR. Two triterpenoid glycosides (compounds 134 and 140) and one flavonoid glycoside (compound 62a or 62b) were showed to be novel compounds. Compounds 125 and 129, as well as 62a,b, were epimers.

  10. Optimization of a gas chromatography-mass spectrometry method with methyl chloroformate derivatization for quantification of amino acids in plant tissue.

    Science.gov (United States)

    Vancompernolle, Bram; Croes, Kim; Angenon, Geert

    2016-04-01

    Rapid, easy and reliable quantification of amino acids is crucial in research on plant amino acid metabolism and nutritional improvement of crops via enrichment of essential amino acids. A recently reported analysis method, based on solid phase extraction (SPE), derivatization with methyl chloroformate and gas chromatography-mass spectrometry was optimized and tested on three-week-old Arabidopsis thaliana leaf tissues. Optimization of the SPE cleanup yielded recovery rates of minimum 95% for all amino acids (except arginine). Variations in accuracy and precision did not exceed 12.5%, except for cysteine, histidine and tryptophane, which were excluded from analysis. Quantification of overlapping peaks for isoleucine/threonine and proline/asparagine was possible by selection of two specific fragment ions for each amino acid. Of the 16 selected amino acids, 14 were quantified successfully in at least 75% of the samples, while methionine and tyrosine were only quantifiable in 6% and 42%, respectively. A case study on the aspartate super pathway confirmed the applicability of the optimized method on wild type and genetically modified plants: external supplementation of methionine or lysine yielded a 146-fold or 27-fold increase in the respective absolute amino acid levels compared with the control treatment. Induced expression of dhdps-r1 (a mutated lysine biosynthesis gene encoding a feedback insensitive enzyme) caused an 83-fold increase in absolute lysine levels. PMID:26994331

  11. Development and validation of a gas chromatography-mass spectrometry method for the determination of phenazopyridine in rat plasma: application to the pharmacokinetic study.

    Science.gov (United States)

    Chen, Qinhua; Li, Kaijun; Zhang, Zhuo; Li, Peng; Liu, Jia; Li, Qiang

    2007-11-01

    Phenazopyridine hydrochloride is a strong analgesic used in the treatment of urinary tract infections. The aim of the present study was to develop a procedure based on gas chromatography-mass spectrometry (GC-MS) for the analysis of phenazopyridine in rat plasma. The method was set up and adapted for the analysis of small biological samples taken from rats. Biological samples were extracted by liquid-liquid extraction. The extraction agent was ethyl acetate. The samples were separated by GC on a DB-5MS analytical column and determined by a quadrupole mass spectrometer detector operated under selected ion monitoring mode. Excellent linearity was found between 0.01 and 1.00 microg/ml (r = 0.9991, n = 9) for plasma samples. The limit of detection (LOD) was 0.3 ng/ml. Within-day and between-day precisions expressed as the relative standard deviation (RSD) for the method were 1.83-4.91% and 2.12-4.76%, respectively. The recoveries for all samples were >90%. The main pharmacokinetic parameters obtained were T(max) = (0.35+/-0.01) h, C(max) = (0.396+/-0.079) microg/ml, AUC = (0.373+/-0.065) h microg/ml and CL = (94.2+/-5.9) ml/g/h. The results presented here clearly indicate that this proposed method could be applicable to investigate the pharmacokinetic of phenazopyridine in rats after administration. (c) PMID:17847064

  12. A novel quantitation approach for maximizing detectable targets for offensive/volatile odorants with diverse functional groups by thermal desorption-gas chromatography-mass spectrometry

    Science.gov (United States)

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2016-01-01

    A multitude of analytical systems are needed to analyze diverse odorants with various functionalities. In this study, an experimental method was developed to assess the maximum covering range of odorants using a single experimental setup consisting of a thermal desorber-gas chromatography-mass spectrometry system. To this end, a total of 20 offensive odorants (aldehyde, ketone, ester, alcohol, aromatic, sulfide, amine, and carboxyl) were selected and tested by a single system. The analytical results of standards and environmental samples were evaluated in a number of respects. In the analysis of the standards, all targets were quantified via Carbopack (C + B + X) tube sampling while operating the thermal desorber at −25 °C. The method detection limits of 18 targets (exception of 2 out of the 20 targets: acetaldehyde and methanethiol) were excellent (mean 0.04 ± 0.03 ppb) in terms of their odor threshold values (74.7 ± 140 ~ 624 ± 1,729 ppb). The analysis of organic fertilizer plant samples at a pig farm (slurry treatment facility, compost facility, and ambient air) confirmed the presence of 18 odorants from 0.03 ppb (dimethyldisulfide, ambient sample) to 522 ppb (methyl ethyl ketone, slurry treatment facility). As such, our method allowed simultaneous quantitation of most key odorants with sufficient reliability and sensitivity. PMID:27404037

  13. 基于柱前衍生-超高效液相色谱-质谱联用技术的植物提取液中氨基化合物代谢谱分析%Metabolic profiling analysis of amino metabolites in plant extract based on pre-column derivatization-ultra high performance liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    张俊杰; 赵春霞; 赵燕妮; 赵洁妤; 李丽丽; 路鑫; 许国旺

    2015-01-01

    Amino metabolites are important compounds that play a key role in plant growth and development. A metabolic profiling analysis method of amino metabolites in plant extract was developed based on pre-column derivatization-ultra high performance liquid chromatography-mass spectrometry. Using the tobacco leaf as an example,a total of 87 amino metabolites, including amino acids,amines,peptides,alkaloids etc. were detected. The repeatability of the method was good with RSDs of 85 amino metabolites between 1. 5% and 18. 8%. Forty-three amino metabolites validated by standard samples showed good linearity with the correlation coefficients of 0. 993-0. 999,covered linear range of four orders of magnitude. The limits of detection were 0. 03-6. 58 ng/mL. The intra-day and inter-day precisions were 0. 7%-15. 6% and 0. 8%-22. 9%,respectively. The recoveries were 74. 4%-122. 7%. The influence of topping on metabolic profiling of amino metabolites in fresh tobacco was investigated using the developed method. The results showed that the amino metabolites in the upper tobacco leaves were most affected than those in the middle and lower leaves. Metabolism of amino metabolites in the upper leaves after topping was mainly towards the alkaloid synthesis. The method integrated the advantages of triple quadrupole mass spectrometry and high resolution quadrupole-time of flight mass spectrometry. It can be used for metabolic profiling analysis of amino metabolites in plant extract with high sensitivity and selectivity.%氨基化合物在植物生长发育中起着重要作用。本文建立了一种基于柱前衍生-超高效液相色谱-质谱联用技术的植物提取液中氨基化合物代谢谱的分析方法。以烟草鲜叶为例,共检测出87种氨基化合物。其中43种氨基化合物的定量分析结果表明,方法的线性相关系数在0.993~0.999之间,线性范围可达到4个数量级,检出限为0.03~6.58 ng/mL,日内、日间精密度分别为0.7

  14. Rapid screening of haloacetamides in water using salt-assisted liquid-liquid extraction coupled injection-port silylation gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Tzu-Ling; Tzing, Shin-Hwa; Ding, Wang-Hsien

    2015-11-27

    The rapid screening of trace amounts of the nitrogenous disinfection by-products, haloacetamides (HAcAms), in drinking and swimming pool water was performed by a simple and reliable procedure based on salt-assisted liquid-liquid extraction (SALLE) combined with injection-port silylation gas chromatography-mass spectrometry (IPS-GC-MS) method. The optimal SALLE conditions involved the injection of 4-mL of ethyl acetate into a 10-mL water sample (pH 7) containing 3-g of sodium sulfate. After vortex extraction for 1min and centrifugation, 10μL of the extract (mixed with 1μL of MTBSTFA) was directly determined by IPS-GC-MS. The limits of quantitation (LOQs) were determined to be 0.03-0.3μg/L. Precision, as indicated by relative standard deviations (RSDs), was less than 10% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 76% and 94%. The SALLE plus IPS-GC-MS was successfully applied to quantitatively determine HAcAms from drinking and swimming pool water samples, and the total concentrations of the compounds ranged from 0.43 to 4.03μg/L.

  15. Gas chromatography-mass spectrometry based metabolomic approach for optimization and toxicity evaluation of earthworm sub-lethal responses to carbofuran.

    Science.gov (United States)

    Mudiam, Mohana Krishna Reddy; Ch, Ratnasekhar; Saxena, Prem Narain

    2013-01-01

    Despite recent advances in understanding mechanism of toxicity, the development of biomarkers (biochemicals that vary significantly with exposure to chemicals) for pesticides and environmental contaminants exposure is still a challenging task. Carbofuran is one of the most commonly used pesticides in agriculture and said to be most toxic carbamate pesticide. It is necessary to identify the biochemicals that can vary significantly after carbofuran exposure on earthworms which will help to assess the soil ecotoxicity. Initially, we have optimized the extraction conditions which are suitable for high-throughput gas chromatography mass spectrometry (GC-MS) based metabolomics for the tissue of earthworm, Metaphire posthuma. Upon evaluation of five different extraction solvent systems, 80% methanol was found to have good extraction efficiency based on the yields of metabolites, multivariate analysis, total number of peaks and reproducibility of metabolites. Later the toxicity evaluation was performed to characterize the tissue specific metabolomic perturbation of earthworm, Metaphire posthuma after exposure to carbofuran at three different concentration levels (0.15, 0.3 and 0.6 mg/kg of soil). Seventeen metabolites, contributing to the best classification performance of highest dose dependent carbofuran exposed earthworms from healthy controls were identified. This study suggests that GC-MS based metabolomic approach was precise and sensitive to measure the earthworm responses to carbofuran exposure in soil, and can be used as a promising tool for environmental eco-toxicological studies.

  16. Gas chromatography-mass spectrometry based metabolomic approach for optimization and toxicity evaluation of earthworm sub-lethal responses to carbofuran.

    Directory of Open Access Journals (Sweden)

    Mohana Krishna Reddy Mudiam

    Full Text Available Despite recent advances in understanding mechanism of toxicity, the development of biomarkers (biochemicals that vary significantly with exposure to chemicals for pesticides and environmental contaminants exposure is still a challenging task. Carbofuran is one of the most commonly used pesticides in agriculture and said to be most toxic carbamate pesticide. It is necessary to identify the biochemicals that can vary significantly after carbofuran exposure on earthworms which will help to assess the soil ecotoxicity. Initially, we have optimized the extraction conditions which are suitable for high-throughput gas chromatography mass spectrometry (GC-MS based metabolomics for the tissue of earthworm, Metaphire posthuma. Upon evaluation of five different extraction solvent systems, 80% methanol was found to have good extraction efficiency based on the yields of metabolites, multivariate analysis, total number of peaks and reproducibility of metabolites. Later the toxicity evaluation was performed to characterize the tissue specific metabolomic perturbation of earthworm, Metaphire posthuma after exposure to carbofuran at three different concentration levels (0.15, 0.3 and 0.6 mg/kg of soil. Seventeen metabolites, contributing to the best classification performance of highest dose dependent carbofuran exposed earthworms from healthy controls were identified. This study suggests that GC-MS based metabolomic approach was precise and sensitive to measure the earthworm responses to carbofuran exposure in soil, and can be used as a promising tool for environmental eco-toxicological studies.

  17. Two-dimensional gas chromatography/mass spectrometry, physical property modeling and automated production of component maps to assess the weathering of pollutants.

    Science.gov (United States)

    Antle, Patrick M; Zeigler, Christian D; Livitz, Dimitri G; Robbat, Albert

    2014-10-17

    Local conditions influence how pollutants will weather in subsurface environments and sediment, and many of the processes that comprise environmental weathering are dependent upon these substances' physical and chemical properties. For example, the effects of dissolution, evaporation, and organic phase partitioning can be related to the aqueous solubility (SW), vapor pressure (VP), and octanol-water partition coefficient (KOW), respectively. This study outlines a novel approach for estimating these physical properties from comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC/MS) retention index-based polyparameter linear free energy relationships (LFERs). Key to robust correlation between GC measurements and physical properties is the accurate and precise generation of retention indices. Our model, which employs isovolatility curves to calculate retention indices, provides improved retention measurement accuracy for families of homologous compounds and leads to better estimates of their physical properties. Results indicate that the physical property estimates produced from this approach have the same error on a logarithmic-linear scale as previous researchers' log-log estimates, yielding a markedly improved model. The model was embedded into a new software program, allowing for automated determination of these properties from a single GC×GC analysis with minimal model training and parameter input. This process produces component maps that can be used to discern the mechanism and progression of how a particular site weathers due to dissolution, organic phase partitioning, and evaporation into the surrounding environment.

  18. Headspace solid-phase microextraction with on-fiber derivatization for the determination of aldehydes in algae by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ma, Jiping; Xiao, Ronghui; Li, Jinhua; Li, Jie; Shi, Benzhang; Liang, Yanjuan; Lu, Wenhui; Chen, Lingxin

    2011-06-01

    A simple, fast, sensitive and cost-effective method based on headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization coupled with gas chromatography-mass spectrometry was developed for the determination of six typical aldehydes, 2E-hexenal, heptanal, 2E-heptenal, 2E,4E-heptadienal, 2E-decenal and 2E,4E-decadienal in laboratory algae cultures. As derivatization reagent, O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride, was loaded onto the poly(dimethylsiloxane)/divinylbenzene fiber for aldehydes on-fiber derivatization prior to HS-SPME. Various influence factors of extraction efficiency were systematically investigated. Under optimized extraction conditions, excellent method performances for all the six aldehydes were attained, such as satisfactory extraction recoveries ranging from 67.1 to 117%, with the precision (relative standard deviation) within 5.3-11.1%, and low detection limits in the range of 0.026-0.044 μg/L. The validated method was successfully applied for the analysis of the aldehydes in two diatoms (Skeletonema costatum and Chaetoceros muelleri), two pyrrophytas (Prorocentrum micans and Scrippsiella trochoidea) and Calanus sinicus eggs (feeding on the two diatoms above). PMID:21567947

  19. High-Performance Chemical Isotope Labeling Liquid Chromatography-Mass Spectrometry for Profiling the Metabolomic Reprogramming Elicited by Ammonium Limitation in Yeast.

    Science.gov (United States)

    Luo, Xian; Zhao, Shuang; Huan, Tao; Sun, Difei; Friis, R Magnus N; Schultz, Michael C; Li, Liang

    2016-05-01

    Information about how yeast metabolism is rewired in response to internal and external cues can inform the development of metabolic engineering strategies for food, fuel, and chemical production in this organism. We report a new metabolomics workflow for the characterization of such metabolic rewiring. The workflow combines efficient cell lysis without using chemicals that may interfere with downstream sample analysis and differential chemical isotope labeling liquid chromatography mass spectrometry (CIL LC-MS) for in-depth yeast metabolome profiling. Using (12)C- and (13)C-dansylation (Dns) labeling to analyze the amine/phenol submetabolome, we detected and quantified a total of 5719 peak pairs or metabolites. Among them, 120 metabolites were positively identified using a library of 275 Dns-metabolite standards, and 2980 metabolites were putatively identified based on accurate mass matches to metabolome databases. We also applied (12)C- and (13)C-dimethylaminophenacyl (DmPA) labeling to profile the carboxylic acid submetabolome and detected over 2286 peak pairs, from which 33 metabolites were positively identified using a library of 188 DmPA-metabolite standards, and 1595 metabolites were putatively identified. Using this workflow for metabolomic profiling of cells challenged by ammonium limitation revealed unexpected links between ammonium assimilation and pantothenate accumulation that might be amenable to engineering for better acetyl-CoA production in yeast. We anticipate that efforts to improve other schemes of metabolic engineering will benefit from application of this workflow to multiple cell types. PMID:26947805

  20. Rapid determination of caffeine in one drop of beverages and foods using drop-to-drop solvent microextraction with gas chromatography/mass spectrometry.

    Science.gov (United States)

    Shrivas, Kamlesh; Wu, Hui-Fen

    2007-11-01

    A simple and rapid sample cleanup and preconcentration method for the quantitative determination of caffeine in one drop of beverages and foods by gas chromatography/mass spectrometry (GC/MS) has been proposed using drop-to-drop solvent microextraction (DDSME). The best optimum experimental conditions for DDSME were: chloroform as the extraction solvent, 5 min extraction time, 0.5 microL exposure volume of the extraction phase and no salt addition at room temperature. The optimized methodology exhibited good linearity between 0.05 and 5.0 microg/mL with correlation coefficient of 0.980. The relative standard deviation (RSD) and limits of detection (LOD) of the DDSME/GC/MS method were 4.4% and 4.0 ng/mL, respectively. Relative recovery of caffeine in beverages and foods were found to be 96.6-101%, which showing good reliability of this method. This DDSME excludes the major disadvantages of conventional method of caffeine extraction, like large amount of organic solvent and sample consumption and long sample pre-treatment process. So, this approach proves that the DDSME/GC/MS technique can be applied as a simple, fast and feasible diagnosis tool for environmental, food and biological application for extremely small amount of real sample analysis. PMID:17904565

  1. Determination of aromatic amines in hair dye and henna samples by ion-pair extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Akyüz, Mehmet; Ata, Sevket

    2008-05-12

    A gas chromatography-mass spectrometry (GC-MS) method has been proposed for the determination of carcinogenic and toxic aromatic amines in hair dye, henna and dyed hair samples. The method includes ion-pair extraction of aromatic amines from aqueous samples with bis-2-ethylhexylphosphate (BEHPA) released after solving the samples in acidic solution followed by sonication, derivatisation of compounds with isobutyl chloroformate (IBCF) and their GC-MS analysis in both electron impact (EI) and positive and negative ion chemical ionisation (PNICI) mode as their isobutyloxycarbonyl (isoBOC) derivatives. The obtained recoveries of aromatic amines ranged from 92.2 to 98.4% and the precision of this method, as indicated by the relative standard deviations (RSDs) was within the range of 0.7-4.2%. The detection limits obtained from calculations by using GC-MS results based on signal-to-noise ratio (S/N)=3 were within the range from 0.02 to 0.20 ng/g. In the present study, the commercially available 54 permanent hair dye, 35 modified or natural henna and 15 dyed hair samples were analysed for the aromatic amines by the proposed method and the method was shown to be suitable to determine the aromatic amine ingredients and metabolites of these commercial products. PMID:18280687

  2. Agarose film liquid phase microextraction combined with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in water.

    Science.gov (United States)

    Sanagi, Mohd Marsin; Loh, Saw Hong; Wan Ibrahim, Wan Aini; Hasan, Mohamed Noor

    2012-11-01

    Agarose film liquid phase microextraction (AF-LPME) procedure for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) in water has been investigated. Agarose film was used for the first time as an interface between donor and acceptor phases in liquid phase microextraction which allowed for selective extraction of the analytes prior to gas chromatography-mass spectrometry. Using 1-octanol as acceptor phase, high enrichment factors in the range of 57-106 for the targeted analytes (fluorene, phenanthrene, fluoranthene and pyrene) were achieved. Under the optimum extraction conditions, the method showed good linearity in the range of 0.1-200 μgL(-1), good correlation coefficients in the range of 0.9963-0.9999, acceptable reproducibility (RSD 6.1-9.2%, n=3), low limits of detection (0.01-0.04 μgL(-1)) and satisfactory relative recoveries (92.9-104.7%). As the AF-LPME device was non-expensive, reuse or recycle of the film was not required, thus eliminating the possibility of analytes carry-over between runs. The AF-LPME technique is environment-friendly and compatible with the green chemistry concept as agarose is biodegradable polysaccharide extracted from seaweed and the procedure requires small volume of organic solvent and generates little waste. The validated method was successfully applied to the analysis of the four analytes in river water samples.

  3. [Determination of 28 organochlorine and pyrethroid pesticides in pine nuts using solid-phase extraction and on-line gel permeation chromatography-gas chromatography/mass spectrometry].

    Science.gov (United States)

    Kang, Qinghe; Wu, Yan; Gao, Kaiyang; Li, Zhibin

    2009-03-01

    An analytical method has been developed for the determination of 28 organochlorine pesticides and pyrethroid pesticides in pine nuts. The sample was extracted With acetonitrile-water (4:1, v/v) as the extraction solution by means of high-speed homogenization. The crude extract was purified by an Aluminium-N solid phase extraction column to remove most of the fat and sterols in the sample, then on-line gel permeation chromatography-gas chromatography/ mass spectrometry (GPC-GC/MS) analysis was performed. The recoveries for the most of pesticides in the sample spiked with the standards of 0.05 mg/kg were 70%-120%, and the relative standard deviations were less than 15%. The limits of detection of 28 organochlorine pesti- and pyrethroid pesticides were 0.002-0.05 mg/kg. The linear relationship and the recovery results were satisfactory. The method is rapid, accurate, highly senstive, and can be used for the simultaneous determination of pesticide residues in pine nuts.

  4. Plant- versus microbial signature in densimetric fractions of mediterranean forest soils: a study by thermochemolysis gas chromatography mass spectrometry

    Science.gov (United States)

    Rovira, Pere; Grasset, Laurent

    2015-04-01

    Plant- versus microbial signature in densimetric fractions of mediterranean forest soils: a study by thermochemolysis gas chromatography mass spectrometry The ageing of a given organic substrate decomposing in soil is strongly dependant of its microbial utilization and transformation (reworking) by the soil microflora. How far a given substrate or soil fraction has gone in this evolution is usually measured by means of molecular signatures, ratios between organic compounds which enlighten us about the origin and/or the degree of microbial reworking of a specific group of compounds: lipids, proteins, lignin, carbohydrates, etc. Owing to the biochemical heterogeneity of decomposing substrates it is unlikely that the degree of microbial reworking can be approached with a single signature. Applying a couple of them is much better, but obtaining a wide collection of molecular signatures can be time consuming. Here, instead of applying specific methods to obtain a collection of specific signatures, we apply TMAH-thermochemolysis to obtain a panoramic view of the biochemical composition of a series of densimetric fractions of soils. From the compounds identified after TMAH-thermochemolysis, a collection of indicators was obtained: (a) ratio between short and long-chained linear alkanoic acids; (b) ratio between branched and long-chained linear alkanoic acids; (c) ratio between C16 and total alpha-omega-alkanedioic acids; (d) ratio microbial to plant-derived 1-methoxyalkanes; (e) ratio syringyl to total lignin-derived phenolic compounds; (f) vanillic acid to vanillin ratio; (g) fucose/glucose ratio; and (h) xylose/glucose ratio. From these indicators a single numerical value is distilled, allowing to order a couple of densimetric fractions of soil organic matter according to its degree of microbial reworking. This approach was applied to the comparison of a couple of densimetric fractions of soil organic matter of three organic H horizons from mediterranean forest soils

  5. Determination of N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) in the general population using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Käfferlein, H U; Angerer, J

    1999-10-01

    Carbamoylation of glutathione, peptides and DNA is thought to be one of the most important reactions occurring in an organism after exposure to nitrosoureas, methylformamides or isocyanates. The carcinogenic effects of carbamoylation are not yet fully clarified. Although carbamoylation is known to occur after occupational exposure, it has never been reported in the general population. To clarify the situation, we investigated the levels of N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) in urine samples from persons without occupational exposure using a sensitive and specific method (gas chromatography-mass spectrometry, GC-MS). AMCC is the degradation product of N-methylcarbamoylated glutathione. The clean-up procedure of urine samples includes two liquid-liquid extraction steps and solid phase extraction using a cation-exchange resin to separate AMCC from other urinary components. N,N-Dimethylpropionic acid amide (DMPA) is used as internal standard. During the preparation of the samples, AMCC is converted to ethyl-N-methylcarbamate (EMC) in the presence of anhydrous potassium carbonate (K2CO3) and ethanol. The reliability and accuracy of this method have been proven in detail. The relative standard deviation for the within-series imprecision for three different concentrations was determined to be between 10.9% and 14.3%, while the relative standard deviation for the between-day imprecision was between 11.3% and 14.8%. The mean recovery for AMCC was determined to be between 79.2% and 85.6%. The limit of detection for the simultaneous measurement of two fragment masses was 30 micrograms L-1. Using this GC-MS method, we analysed urine samples from 42 individuals of the general population in order to determine their urinary excretion of AMCC. It was identified in 40 samples. The mean concentration was 40 micrograms L-1. AMCC can be formed in two ways. The first possibility is the dietary intake of isothiocyanates, especially methyl isothiocyanate, which is a component

  6. Detection of Volatile Aroma Compounds of Morchella by Headspace Gas Chromatography Mass Spectrometry (HS-GC/MS

    Directory of Open Access Journals (Sweden)

    Hatira TAŞKIN

    2013-05-01

    Full Text Available   This study was conducted at the Horticulture Department of Çukurova University, Adana, Turkey, in 2010 to determine the volatile aroma compounds of Morchella mushroom. Fresh samples of Morchella esculenta (Sample 1 and Morchella elata (Sample 2 were collected from Çanakkale (Sample 1 and Mersin (Sample 2 provinces in Turkey in the spring of 2010. Volatile aroma compounds were analyzed by headspace gas chromatography mass spectrometry (HS-GC/MS. A total of 31 aroma compounds were identified in the 2 analyzed samples: 7 alcohols, 7 esters, 7 ketones, 3 acids, 2 aldehydes, 1 terpene, phenol, 1-propanamine, geranyl linalool, and quinoline. Seventeen aroma components were identified in Sample 1, and 18 compounds were found in Sample 2. Phenol was determined as the major aroma compound in both Sample 1 and Sample 2, at 50.888% and 58.293% content, respectively. Alcohols, especially 1-octen-3-ol, were detected as the second major aroma components in Sample 1 and Sample 2, at 15.500% and 5.660% content, respectively. Carbamic acid, methyl ester was found only in Sample 1, at 11.379% content. The aroma components detected in the two samples differed. 1-Octadecanol; cyclooctylalcohol; trans-2-undecen-1-ol; butanoic acid, butyl ester (CAS; carbamic acid, methyl ester; 2-ethylhexyl-2-ethylhexanoate; phthalic acid, decyl isobutyl ester; 2,2,4-trimethyl-1,3-pentanediol diisobutyrate; decanal; nonanal; 7,9-di-tert-butyl-1-oxaspiro(4.5deca-6,9-diene-2,8-dione; 2,5-cyclohexadiene-1,4-dione; 2,6-bis(1,1-dimethylethyl; and trans-alpha-bisabolene were detected only in Sample 1. Ethanol; silanediol, 2-methylaminoethanol; L-alanine, ethyl ester; carbonic acid, dodecyl isobutyl ester; acetic acid; butanoic acid; 2,3,4H-pyran-4-one; 5,9-undecadien-2-one; cyclooctene; 2-cyclopenten-1-one; 1-propanamine; geranyl linalool; and quinoline were determined only in Sample 2.

  7. Solid-phase microextraction/gas chromatography-mass spectrometry method optimization for characterization of surface adsorption forces of nanoparticles.

    Science.gov (United States)

    Omanovic-Miklicanin, Enisa; Valzacchi, Sandro; Simoneau, Catherine; Gilliland, Douglas; Rossi, Francois

    2014-10-01

    A complete characterization of the different physico-chemical properties of nanoparticles (NPs) is necessary for the evaluation of their impact on health and environment. Among these properties, the surface characterization of the nanomaterial is the least developed and in many cases limited to the measurement of surface composition and zetapotential. The biological surface adsorption index approach (BSAI) for characterization of surface adsorption properties of NPs has recently been introduced (Xia et al. Nat Nanotechnol 5:671-675, 2010; Xia et al. ACS Nano 5(11):9074-9081, 2011). The BSAI approach offers in principle the possibility to characterize the different interaction forces exerted between a NP's surface and an organic--and by extension biological--entity. The present work further develops the BSAI approach and optimizes a solid-phase microextraction gas chromatography-mass spectrometry (SPME/GC-MS) method which, as an outcome, gives a better-defined quantification of the adsorption properties on NPs. We investigated the various aspects of the SPME/GC-MS method, including kinetics of adsorption of probe compounds on SPME fiber, kinetic of adsorption of probe compounds on NP's surface, and optimization of NP's concentration. The optimized conditions were then tested on 33 probe compounds and on Au NPs (15 nm) and SiO2 NPs (50 nm). The procedure allowed the identification of three compounds adsorbed by silica NPs and nine compounds by Au NPs, with equilibrium times which varied between 30 min and 12 h. Adsorption coefficients of 4.66 ± 0.23 and 4.44 ± 0.26 were calculated for 1-methylnaphtalene and biphenyl, compared to literature values of 4.89 and 5.18, respectively. The results demonstrated that the detailed optimization of the SPME/GC-MS method under various conditions is a critical factor and a prerequisite to the application of the BSAI approach as a tool to characterize surface adsorption properties of NPs and therefore to draw any further

  8. Solid-phase microextraction/gas chromatography-mass spectrometry method optimization for characterization of surface adsorption forces of nanoparticles.

    Science.gov (United States)

    Omanovic-Miklicanin, Enisa; Valzacchi, Sandro; Simoneau, Catherine; Gilliland, Douglas; Rossi, Francois

    2014-10-01

    A complete characterization of the different physico-chemical properties of nanoparticles (NPs) is necessary for the evaluation of their impact on health and environment. Among these properties, the surface characterization of the nanomaterial is the least developed and in many cases limited to the measurement of surface composition and zetapotential. The biological surface adsorption index approach (BSAI) for characterization of surface adsorption properties of NPs has recently been introduced (Xia et al. Nat Nanotechnol 5:671-675, 2010; Xia et al. ACS Nano 5(11):9074-9081, 2011). The BSAI approach offers in principle the possibility to characterize the different interaction forces exerted between a NP's surface and an organic--and by extension biological--entity. The present work further develops the BSAI approach and optimizes a solid-phase microextraction gas chromatography-mass spectrometry (SPME/GC-MS) method which, as an outcome, gives a better-defined quantification of the adsorption properties on NPs. We investigated the various aspects of the SPME/GC-MS method, including kinetics of adsorption of probe compounds on SPME fiber, kinetic of adsorption of probe compounds on NP's surface, and optimization of NP's concentration. The optimized conditions were then tested on 33 probe compounds and on Au NPs (15 nm) and SiO2 NPs (50 nm). The procedure allowed the identification of three compounds adsorbed by silica NPs and nine compounds by Au NPs, with equilibrium times which varied between 30 min and 12 h. Adsorption coefficients of 4.66 ± 0.23 and 4.44 ± 0.26 were calculated for 1-methylnaphtalene and biphenyl, compared to literature values of 4.89 and 5.18, respectively. The results demonstrated that the detailed optimization of the SPME/GC-MS method under various conditions is a critical factor and a prerequisite to the application of the BSAI approach as a tool to characterize surface adsorption properties of NPs and therefore to draw any further

  9. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  10. Analyses of nitrobenzene,benzene and aniline in environmental water samples by headspace solid phase micro-extraction coupled with gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    CHEN Ming; YIN Yongguang; TAI Chao; ZHANG Qinghua; LIU Jiyan; HU Jingtian; JIANG Guibin

    2006-01-01

    A headspace solid phase microextraction coupled with gas chromatography mass spectrometry (HS-SPME/GC-MS) method was established for analyzing nitrobenzene, benzene and aniline in environmental water samples simultaneously.Factors affecting extraction efficiency (SPME fiber selection, acidity, temperature, salt addition, extraction time, headspace, etc) were verified. Under optimal extraction conditions, the detection limits are 0.50, 0.11 and 1.00 μg/L for nitrobenzene, benzene and aniline, respectively. The results indicate that this method is capable of making sensitive and accuracy analyses on nitrobenzene, benzene and aniline in environmental water samples.

  11. Chemometric-based determination of polycyclic aromatic hydrocarbons in aqueous samples using ultrasound-assisted emulsification microextraction combined to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ahmadvand, Mohammad; Sereshti, Hassan; Parastar, Hadi

    2015-09-25

    In the present research, ultrasonic-assisted emulsification-microextraction (USAEME) coupled with gas chromatography-mass spectrometry (GC-MS) has been proposed for analysis of thirteen environmental protection agency (EPA) polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Tetrachloroethylene was selected as extraction solvent. The main parameters of USAEME affecting the efficiency of the method were modeled and optimized using a central composite design (CCD). Under the optimum conditions (9μL for extraction solvent, 1.15% (w/v) NaCl (salt concentration) and 10min for ultrasonication time), preconcentration factor (PF) of the PAHs was in the range of 500-950. In order to have a comprehensive analysis, multivariate curve resolution-alternating least squares (MCR-ALS) as a second-order calibration algorithm was used for resolution, identification and quantification of the target PAHs in the presence of uncalibrated interferences. The regression coefficients and relative errors (REs, %) of calibration curves of the PAHs were in the satisfactory range of 0.9971-0.9999 and 1.17-6.59%, respectively. Furthermore, analytical figures of merit (AFOM) for univariate and second-order calibrations were obtained and compared. As an instance, the limit of detections (LODs) of target PAHs were in the range of 1.87-18.9 and 0.89-6.49ngmL(-1) for univariate and second-order calibration, respectively. Finally, the proposed strategy was used for determination of target PAHs in real water samples (tap and hookah waters). The relative recoveries (RR) and the relative standard deviations (RSDs) were 68.4-109.80% and 2.15-6.93%, respectively. It was concluded that combination of multivariate chemometric methods with USAEME-GC-MS can be considered as a new insight for the analysis of target analytes in complex sample matrices. PMID:26319375

  12. Two-dimensional turbulent flow chromatography coupled on-line to liquid chromatography-mass spectrometry for solution-based ligand screening against multiple proteins.

    Science.gov (United States)

    Zhou, Jian-Liang; An, Jing-Jing; Li, Ping; Li, Hui-Jun; Jiang, Yan; Cheng, Jie-Fei

    2009-03-20

    We present herein a novel bioseparation/chemical analysis strategy for protein-ligand screening and affinity ranking in compound mixtures, designed to increase screening rates and improve sensitivity and ruggedness in performance. The strategy is carried out by combining on-line two-dimensional turbulent flow chromatography (2D-TFC) with liquid chromatography-mass spectrometry (LC-MS), and accomplished through the following steps: (1) a reversed-phase TFC stage to separate the protein/ligand complex from the unbound free molecules, (2) an on-line dissociation process to release the bound ligands from the complexes, and (3) a second mixed-mode cation-exchange/reversed-phase TFC stage to trap the bound ligands and to remove the proteins and salts, followed by LC-MS analysis for identification and determination of the binding affinities. The technique can implement an ultra-fast isolation of protein/ligand complex with the retention time of a complex peak in about 5s, and on-line prepare the "clean" sample to be directly compatible with the LC-MS analysis. The improvement in performance of this 2D-TFC/LC-MS approach over the conventional approach has been demonstrated by determining affinity-selected ligands of the target proteins acetylcholinesterase and butyrylcholinesterase from a small library with known binding affinities and a steroidal alkaloid library composed of structurally similar compounds. Our results show that 2D-TFC/LC-MS is a generic and efficient tool for high-throughput screening of ligands with low-to-high binding affinities, and structure-activity relationship evaluation. PMID:19203758

  13. Ultrasound-assisted dispersive liquid-liquid microextraction for the determination of synthetic musk fragrances in aqueous matrices by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Homem, Vera; Alves, Alice; Alves, Arminda; Santos, Lúcia

    2016-01-01

    A rapid and simple method for the simultaneous determination of twelve synthetic musks in water samples, using ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was successfully developed. The influence of seven factors (volume of the extraction solvent and disperser solvent, sample volume, extraction time, ionic strength, type of extraction and disperser solvent) affecting the UA-DLLME extraction efficiency was investigated using a screening design. The significant factors were selected and optimised employing a central composite design: 80 μL of chloroform, 880 μL of acetonitrile, 6 mL of sample volume, 3.5% (wt) of NaCl and 2 min of extraction time. Under the optimised conditions, this methodology was successfully validated for the analysis of 12 synthetic musk compounds in different aqueous samples (tap, sea and river water, effluent and influent wastewater). The proposed method showed enrichment factors between 101 and 115 depending on the analyte, limits of detection in the range of 0.004-54 ng L(-1) and good repeatability (most relative standard deviation values below 10%). No significant matrix effects were found, since recoveries ranged between 71% and 118%. Finally, the method was satisfactorily applied to the analysis of five different aqueous samples. Results demonstrated the existence of a larger amount of synthetic musks in wastewaters than in other water samples (average concentrations of 2800 ng L(-1) in influent and 850 ng L(-1) in effluent). Galaxolide, tonalide and exaltolide were the compounds most detected.

  14. Ultrasound-assisted dispersive liquid-liquid microextraction for the determination of synthetic musk fragrances in aqueous matrices by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Homem, Vera; Alves, Alice; Alves, Arminda; Santos, Lúcia

    2016-02-01

    A rapid and simple method for the simultaneous determination of twelve synthetic musks in water samples, using ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was successfully developed. The influence of seven factors (volume of the extraction solvent and disperser solvent, sample volume, extraction time, ionic strength, type of extraction and disperser solvent) affecting the UA-DLLME extraction efficiency was investigated using a screening design. The significant factors were selected and optimised employing a central composite design: 80 μL of chloroform, 880 μL of acetonitrile, 6 mL of sample volume, 3.5% (wt) of NaCl and 2 min of extraction time. Under the optimised conditions, this methodology was successfully validated for the analysis of 12 synthetic musk compounds in different aqueous samples (tap, sea and river water, effluent and influent wastewater). The proposed method showed enrichment factors between 101 and 115 depending on the analyte, limits of detection in the range of 0.004-54 ng L(-1) and good repeatability (most relative standard deviation values below 10%). No significant matrix effects were found, since recoveries ranged between 71% and 118%. Finally, the method was satisfactorily applied to the analysis of five different aqueous samples. Results demonstrated the existence of a larger amount of synthetic musks in wastewaters than in other water samples (average concentrations of 2800 ng L(-1) in influent and 850 ng L(-1) in effluent). Galaxolide, tonalide and exaltolide were the compounds most detected. PMID:26653427

  15. Graphitic carbon nitrides modified hollow fiber solid phase microextraction for extraction and determination of uric acid in urine and serum coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sun, Ying-pei; Chen, Juan; Qi, Huan-yang; Shi, Yan-ping

    2015-11-01

    An elevated uric acid (UA) in urine or serum can affect renal function and blood pressure, which is an indicator of gout, cardiovascular and renal diseases, hypertension, etc. In this work, a new type of mixed matrix membrane (MMM), based on graphitic carbon nitrides (g-CNs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine UA in urine and serum followed by gas chromatography-mass spectrometry (GC/MS). The porous g-CNs were dispersed in ammonia, and then the exfoliated g-CNs nanosheets were held in the pores of HF by capillary forces and sonification. The prepared g-CNs modified HF (g-CNs-HF) was immersed in biofluid directly to extract UA with SPME mode and the solvent-free mode is convenient for further derivatization and analysis. To achieve the highest extraction efficiency (EF), main extraction and derivatization parameters, such as g-CNs-HF immobilizing time, sonification power and time of extraction, derivatization and desorption time, were optimized. Under the optimum extraction conditions, a favorable linearity of UA was obtained in the range 0.1-200μgmL(-1) with correlation coefficients higher than 0.9990, and the average recoveries at three spiked levels of UA in urine and serum ranged from 80.7% to 121.6%, from 84.7% to 101.1%, respectively. The obtained results demonstrated the developed g-CNs-HF-SPME is a simple, rapid, cost-effective, solvent-free method for the analysis of UA in biofluid.

  16. [Determination of 21 organophosphorus pesticides in tea by gas chromatography-mass spectrometry coupled with hydroxylated multi-walled carbon nanotubes based on dispersive solid-phase extraction].

    Science.gov (United States)

    Rong, Jiefeng; Wei, Hang; Li, Yijun; Huang, Huoshui; Xu, Meizhu

    2016-02-01

    A rapid determination method of 21 organophosphorus pesticides in tea was developed by QuEChERS method using modified multi-walled carbon nanotubes (MWCNTs-OH), primary-secondary amine (PSA) and MgSO4 coupled with gas chromatography-mass spectrometry. The pesticide residues in tea were extracted with a hexane-acetone (2:1, v/v) mixture, and cleaned up by dispersive solid-phase extraction using MWCNTs-OH and primary-secondary amine (PSA) as the sorbents. After centrifugation and filtration, the target compounds were analyzed by gas chromatography-mass spectrometry and quantified by the external standard method. Under the optimized conditions, good linearities were obtained in the range of 0. 01- 0. 50 mg/kg. The average recoveries were in the range of 81. 5% -109. 4% at three spiked levels, with relative standard deviations (RSDs, n = 5 ) of 2. 3% - 10. 6%. The limits of quantification were 0. 001-0. 040 mg/kg. This method is simple, fast, sensitive, cheap, and can meet the requirements of the rapid detection of organophosphorus pesticides in tea.

  17. [Determination of 21 organophosphorus pesticides in tea by gas chromatography-mass spectrometry coupled with hydroxylated multi-walled carbon nanotubes based on dispersive solid-phase extraction].

    Science.gov (United States)

    Rong, Jiefeng; Wei, Hang; Li, Yijun; Huang, Huoshui; Xu, Meizhu

    2016-02-01

    A rapid determination method of 21 organophosphorus pesticides in tea was developed by QuEChERS method using modified multi-walled carbon nanotubes (MWCNTs-OH), primary-secondary amine (PSA) and MgSO4 coupled with gas chromatography-mass spectrometry. The pesticide residues in tea were extracted with a hexane-acetone (2:1, v/v) mixture, and cleaned up by dispersive solid-phase extraction using MWCNTs-OH and primary-secondary amine (PSA) as the sorbents. After centrifugation and filtration, the target compounds were analyzed by gas chromatography-mass spectrometry and quantified by the external standard method. Under the optimized conditions, good linearities were obtained in the range of 0. 01- 0. 50 mg/kg. The average recoveries were in the range of 81. 5% -109. 4% at three spiked levels, with relative standard deviations (RSDs, n = 5 ) of 2. 3% - 10. 6%. The limits of quantification were 0. 001-0. 040 mg/kg. This method is simple, fast, sensitive, cheap, and can meet the requirements of the rapid detection of organophosphorus pesticides in tea. PMID:27382726

  18. Salt-assisted dispersive liquid-liquid microextraction coupled with programmed temperature vaporization gas chromatography-mass spectrometry for the determination of haloacetonitriles in drinking water.

    Science.gov (United States)

    Ma, Huilian; Li, Yun; Zhang, Haijun; Shah, Syed Mazhar; Chen, Jiping

    2014-09-01

    We report here a new analytical method for the simultaneous determination of seven haloacetonitriles (HANs) in drinking water by coupling salt-assisted dispersive liquid-liquid microextraction (SADLLME) with programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS). The newly developed method involves the dispersion of the extractant in aqueous sample by addition of a few grams of salt and no dispersion liquid was required as compared to the traditional DLLME methods. The extractant (CH2Cl2, 50μL) and the salt (Na2SO4, 2.4g) were successively added to water (8mL) in a conical centrifuge tube that was shaken for 1min and centrifuged (3500rpm, 3min). The aliquot of sedimented phase (4μL) was then directly injected into the PTV-GC-MS system. The limits of detection and quantification for the HANs were 0.4-13.2ngL(-1) and 1.2-43.9ngL(-1), respectively. The calibration curves showed good linearity (r(2)≥0.9904) over 3 orders of magnitude. The repeatability of the method was investigated by evaluating the intra- and inter-day precisions. The relative standard deviations (RSDs) obtained were lower than 10.2% and 7.8% at low and high concentration levels. The relative recoveries ranged from 79.3% to 105.1%. The developed methodology was applied for the analysis of seven HANs in several drinking water samples in coastal and inland cities of China. It was demonstrated to be a simple, sensible, reproducible and environment friendly method for the determination of trace HANs in drinking water samples.

  19. [Determination of tris (2-chloroethyl) phosphate in leather by gas chromatography-mass spectrometry coupled with mixed-mode sorbent solid phase extraction].

    Science.gov (United States)

    Zhang, Weiya; Zhu, Yuling; Wang, Chengyun; Li, Lixia; Zhang, Junqing; Xing, Jun

    2014-10-01

    Leather is one of the important exporting products to European Union (EU), and tris(2-chloroethyl) phosphate (TCEP) is a commonly used flame retardant in leather and leather products. Recently, TCEP has been classified as a kind of substance of very high concern (SVHC) by EU for its carcinogenicity and reproductive toxicity. But to date, there is not a recognized method for the determination of TCEP in leather and leather products due to the serious matrix interferences and relatively low recovery of TCEP. In this work, a home-made mixed-mode sorbent (Silica-WCX) with carboxyl and alkyl groups was tested as the sorbent of solid phase extraction (SPE) to extract TECP from leather. The results demonstrated that, making the carboxyl groups protonized under acidic condition, Silica-WCX exhibited better extraction performance towards TCEP over some frequently used commercial sorbents tested. After the optimization of the SPE conditions based on Silica-WCX, a method of gas chromatography/mass spectrometry (GC-MS) was established for the determination of TCEP in leather samples. The linear range for TCEP ranged from 0.10 to 100.0 μg/L and the limit of quantification (LOQ, S/N = 10) was 44.46 ng/kg. The recoveries of TCEP spiked in samples at varied levels were in the range of 91.45%-99.98% with the relative standard deviations (RSDs) of 4.33%-5.97%. The method is simple, sensitive and reliable for the analysis of TCEP in leather and leather products.

  20. Study on seafood volatile profile characteristics during storage and its potential use for freshness evaluation by headspace solid phase microextraction coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Zhuomin; Li, Gongke; Luo, Lin; Chen, Guonan

    2010-02-01

    Seafood volatile profile characteristics at different storage phases are various and can be used for freshness evaluation during storage. It is imperative to obtain the full volatile information prior to the further study of seafood volatile profile characteristics during storage. Also, the efficient data-processing method is another important factor for the interpretation of seafood volatile profile characteristics during storage and related potential volatile markers. In this work, a new analytical strategy, including the efficient sampling technique, sensitive detection and suitable data-processing method, for seafood freshness evaluation was developed based on the volatile profile characteristics during storage. First, the study of volatiles of seafood samples including razor clam, redspot swimming crab and prawn at different storage phases were conducted by headspace solid phase microextraction (HSSPME) followed by gas chromatography-mass spectrometry (GC-MS) detection. Then, seafood volatile profile characteristics at different storage phases were statistically interpreted by a combination data-processing method including normalization, principle component analysis (PCA) and common model strategy. The different seafood volatile profile characteristics and potential volatile markers were attempted to be distilled. The results tentatively suggested that the different seafood volatile profile characteristics during storage could reflect the transitional changing seafood freshness and provide more precise warning information for seafood spoilage during storage than any single chemical markers. This work developed an analytical method for study of seafood volatile profile characteristics and tentatively proposed a new idea of using seafood volatile profile characteristics during storage for the freshness evaluation from the point of view of analytical chemistry. PMID:20103118

  1. [Exploring the mechanism of rhizoma coptidis in treating type II diabetes mellitus based on metabolomics by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Wang, Jing; Yuan, Zimin; Kong, Hongwei; Li, Yong; Lu, Xin; Xu, Guowang

    2012-01-01

    Metabolomics was used to explore the mechanism of Rhizoma coptidis in treating type II diabetes mellitus. The rat model of type II diabetes mellitus was constructed by an injection of streptozocin (40 mg/kg), along with diets of fat emulsion. The rats were divided into four groups, the control group, the model group, the Rhizoma coptidis group (10 g/kg) and the metformin group (0.08 g/kg). After the treatment for 30 d, blood samples were collected to test biomedical indexes, and 24 h urine samples were collected for the metabolomics experiment. In the Rhizoma coptidis group, fasting blood glucose (FBG), total cholesterol (TC) and total plasma triglycerides (TG) were significantly decreased by 59.26%, 58.66% and 42.18%, respectively, compared with those in the model group. Based on gas chromatography-mass spectrometry, a urinary metabolomics method was used to study the mechanism of Rhizoma coptidis in treating diabetes mellitus. Based on the principal component analysis, it was found that the model group and control group were separated into two different clusters. The Rhizoma coptidis group was located between the model group and the control group, closer to the control group. Twelve significantly changed metabolites of diabetes mellitus were detected and identified, including 4-methyl phenol, benzoic acid, aminomalonic acid, and so on. After diabetic rats were administered with Rhizoma coptidis, 7 metabolites were significantly changed, and L-ascorbic acid and aminomalonic acid which related with the oxidative stress were significantly regulated to normal. The pharmacological results showed that Rhizoma coptidis could display anti-hyperglycemic and anti-hyperlipidemic effects. The Rhizoma coptidis had antioxidation function in preventing the occurrence of complications with diabetes mellitus to some extent. The work illustrates that the metabolomics method is a useful tool to study the treatment mechanism of traditional Chinese medicine.

  2. Determination of geosmin and 2-methylisoborneol in water and wine samples by ultrasound-assisted dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cortada, Carol; Vidal, Lorena; Canals, Antonio

    2011-01-01

    A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USADLLME) procedure has been developed to preconcentrate geosmin and 2-methylisoborneol (MIB) from water and wine samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach was developed by means of a Plackett-Burman design for screening and selecting the significant variables involved in the USADLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: solvent volume, 8μL; solvent type: tetrachloroethylene; sample volume, 12 mL; centrifugation speed, 2300 rpm; extraction temperature 20 °C; extraction time, 3 min; and centrifugation time, 3 min. Under the optimized experimental conditions the method gave good levels of repeatability with coefficient of variation under 11% (n=10). Limits of detection were 2 and 9 ng L⁻¹ for geosmin and MIB, respectively. Calculated calibration curves gave high levels of linearity with correlation coefficient values of 0.9988 and 0.9994 for geosmin and MIB, respectively. Finally, the proposed method was applied to the analysis of two water (reservoir and tap) samples and three wine (red, rose and white) samples. The samples were previously analyzed and confirmed free of target analytes. Recovery values ranged between 70 and 113% at two spiking levels (0.25 μg L⁻¹ and 30 ng L⁻¹) showing that the matrix had a negligible effect upon extraction. Only red wine showed a noticeable matrix effect (70-72% recovery). Similar conclusions have been obtained from an uncertainty budget evaluation study.

  3. Determination of alkylphenols and phthalate esters in vegetables and migration studies from their packages by means of stir bar sorptive extraction coupled to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2012-06-01

    This paper describes a method for the determination of three alkylphenols (APs), 4-tert-octylphenol (tOP), 4-n-octylphenol (OP) and 4-nonylphenol (NP), and six phthalate esters (PEs), dimethylphthalate (DMP), diethylphthalate (DEP), di-n-butylphthalate (DBP), n-butylbenzylphthalate (BBP), di-2-ethylhexylphthalate (DEHP) and di-n-octylphthalate (DOP), in vegetables using stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Ultrasonic radiation was used to extract the analytes from the solid food matrix, and the extract obtained was preconcentrated by SBSE. The different parameters affecting both stages were carefully optimized. The method was applied to analyze commercial vegetables, in the form of plastic packed salads and canned greens, as well as the corresponding filling liquids of the canned food. Quantification of the samples was carried out against aqueous standards using an internal standard (anthracene). The analysis of a 2 g vegetable sample provided detection limits between 12.7 and 105.8 pg g⁻¹ for OP and DEHP, respectively. Migration studies from the plastic packages of the vegetables samples analyzed were carried out. DEP, DBP and DEHP were found to have migrated from the bags to the simulant and the same compounds were quantified in lettuce, corn salad, arugula, parsley and chard, at concentration levels in the 8-51 ng g⁻¹ range. However, OP and NP were found in only two vegetable samples and one filling liquid, but neither was detected in any package. The proposed method provided recoveries of 83-118%.

  4. Static headspace gas chromatography-mass spectrometry for the one-step derivatisation and extraction of eleven aldehydes in drinking water.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2013-09-13

    Low-molecular-mass aldehydes (LMMAs) are water disinfection by-products formed by the reaction of ozone and/or chlorine with natural organic matter in water. LMMAs are mutagenic and carcinogenic compounds, which are detected at ng/L levels in water. An analytical method that allows simultaneous derivatisation and extraction of LMMAs in water has been developed using the classical static headspace technique coupled with gas chromatography-mass spectrometry (HS-GC-MS). Important parameters controlling the derivatisation of LMMAs with o-2,3,4,5,6-pentafluorobenzylhydroxylamine, oxime-products extraction and headspace generation were optimised to obtain the highest sensitivity, completing the entire process in 20min. For the first time the derivatisation reaction was carried out at alkaline pH adjusted with sodium hydrogen carbonate which exerts a significant enhancement effect on the derivatisation efficiency of the aldehydes; up to 20-fold with respect to those obtained in weak acid media as recommended by EPA Method 556.1. The addition of 200μL of n-hexane, as a chemical modifier, favoured the volatilisation of oxime-products, increasing the sensitivity of the method. The proposed method allows the achieving of detection limits from 2 to 80ng/L and has excellent precision (RSD average value of 6.4%) and accuracy (recovery ranging from 97% to 99%) for LMMA quantifications in drinking water samples. Finally, the HS-GC-MS method was validated relative to EPA Method 556.1 for the analysis of drinking water samples subjected to several disinfection treatments.

  5. A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry.

    Science.gov (United States)

    Jumaah, Firas; Plaza, Merichel; Abrahamsson, Victor; Turner, Charlotta; Sandahl, Margareta

    2016-08-01

    In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for α-carotene and astaxanthin, respectively, whereas limit of quantification (LOQ) was in the range of 7.8 and 58.0 ng/mL for α-carotene and astaxanthin, respectively. Repeatability and intermediate precision of the developed UHPSFC-MS method were determined and found to be RSD high performance supercritical fluid chromatography-a rapid separation method for the analysis of carotenoids in rosehip and microalgae samples. PMID:27349917

  6. Analysis of odors from veal by Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry%固相微萃取-气相色谱-质谱联用法检测小白牛肉的挥发性成分

    Institute of Scientific and Technical Information of China (English)

    魏晋梅; 罗玉柱; 王继卿; 师希雄; 刘秀; 胡江; 成述儒; 李少斌

    2011-01-01

    A method for the determination of volatile compounds from veal using Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry(SPME-GC-MS)was presented.Totally 125 volatile flavor compounds were detected,and 49 components were identified by qualitative and quantitative analysis.The content of them account for 93.994%,and they were 15 aldehydes,10 alcohols,8 hydrocarbons,3 ester,3 phenols,2 acids,6 ketones and 2 heterocyclic compounds.Among these compounds,Hexanal,Nonanal,Octanal,1-Octen-3-ol,1-(2-nitropropyl)-Cyclohexanol,Heptanal,Butylated Hydroxytoluene,n-Caproic acid vinyl ester,2-pentyl-Furan and 1-Octanol were the important flavor compounds in veal.%采用固相微萃取-气相色谱-质谱联用法(Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry)分析检测了小白牛肉的挥发性风味物质,共分离检测得到125种化合物,定性和定量鉴定得到49种化合物,占总化合物的93.994%,其中醛类15种、醇类10种、烃类8种、酯类3种、酚类3种、酸类2种、杂环类2种、酮类6种。初步判断己醛、壬醛、辛醛、1-辛烯-3-醇、1-(2-硝基丙基)-环己醇、庚醛、二叔丁基对甲酚、N-己酸乙烯酯、2-戊基呋喃、1-辛醇等为小白牛肉的主体香味成分。

  7. Abuse of nutmeg (Myristica fragrans Houtt.): studies on the metabolism and the toxicologic detection of its ingredients elemicin, myristicin, and safrole in rat and human urine using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Beyer, Jochen; Ehlers, Dorothea; Maurer, Hans H

    2006-08-01

    Seeds of nutmeg are used as spice, but they are also abused because of psychotropic effects described after ingestion of large doses. It was postulated that these effects could be attributable to metabolic formation of amphetamine derivatives from the main nutmeg ingredients elemicin (EL), myristicin (MY), and safrole (SA). In a case of a suspected nutmeg abuse, neither such amphetamine derivatives nor the main nutmeg ingredients could be detected in urine. The metabolites of EL, MY, and SA were identified using gas chromatography-mass spectrometry in rat urine and their presence in human urine of the nutmeg abuser was confirmed. The identified metabolites indicated that EL, MY, and SA were once and twice hydroxylated at the side chain. In addition, EL was O-demethylated at 2 positions followed by side chain hydroxylation. MY and SA were demethylenated and subsequently methylated. In the human urine sample, the following metabolites could be identified: O-demethyl elemicin, O-demethyl dihydroxy elemicin, demethylenyl myristicin, dihydroxy myristicin, and demethylenyl safrole. As in the human urine sample, neither amphetamine derivatives nor the main nutmeg ingredients could be detected in the rat urine samples. Finally, toxicologic detection of nutmeg abuse was possible by identification of the described metabolites of the EL, MY, and SA in urine applying the authors' systematic toxicologic analysis procedure using full-scan gas chromatography-mass spectrometry after acid hydrolysis, liquid-liquid extraction of analytes, and microwave-assisted acetylation of extracted analytes.

  8. IDENTIFICATION OF PHYTO-COMPONENTS AND ITS BIOLOGICAL ACTIVITIES OF ALOE VERA THROUGH THE GAS CHROMATOGRAPHY-MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    P.T.V Lakshmi

    2011-05-01

    Full Text Available In this study, the bioactive components of Aloe vera leaves have been evaluated using GC/MS. The chemical compositions of the n-hexane extract of Aloe vera were investigated using Perkin-Elmer Gas Chromatography–Mass Spectrometry, while the mass spectra of the compounds found in the extract was matched with the National Institute of Standards and Technology (NIST library. GC/MS analysis of n-hexane extract of Aloe vera revealed the existence of twenty six bioactive compounds. The results of this study offer a platform of using Aloe vera as herbal drug for cancer studies.

  9. IDENTIFICATION OF PHYTO-COMPONENTS AND ITS BIOLOGICAL ACTIVITIES OF ALOE VERA THROUGH THE GAS CHROMATOGRAPHY-MASS SPECTROMETRY

    OpenAIRE

    P T.V Lakshmi; Pa Rajalakshmi

    2011-01-01

    In this study, the bioactive components of Aloe vera leaves have been evaluated using GC/MS. The chemical compositions of the n-hexane extract of Aloe vera were investigated using Perkin-Elmer Gas Chromatography–Mass Spectrometry, while the mass spectra of the compounds found in the extract was matched with the National Institute of Standards and Technology (NIST) library. GC/MS analysis of n-hexane extract of Aloe vera revealed the existence of twenty six bioactive compounds. The results of ...

  10. Method Development and Validation for Determining 1,3-Butadiene in Human Blood by Gas Chromatography-Mass Spectrometry and Head-Space Gas Chromatography%Method Development and Validation for Determining1,3-Butadiene in Human Blood by Gas Chromatography-Mass Spectrometry and Head-Space Gas Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG Su-jing; SHEN Bao-hua; ZHUO Xian-yi

    2013-01-01

    To develop a simple,validated method for identifying and quantifying 1,3-butadiene (BD) in human blood by gas chromatography-mass spectrometry (GC-MS) and head-space gas chromatography (HS-GC).BD was identified by GC-MS and HS-GC,and quantified by HS-GC.The method showed that BD had a good linearity from 50 to 500 μg/mL (r>0.99).The limits of detection and quantification were 10 μg/mL and 50 μg/mL,respectively.Both the intra-day precision and inter-day precision were <6.08%,and the accuracy was 96.98%-103.81%.The method was applied to an actual case,and the concentration of BD in the case was 242 μg/mL in human blood.This simple method is found to be useful for the routine forensic analysis of acute exposure to BD.

  11. Tissue-specific metabolite profiling of Cyperus rotundus L. rhizomes and (+)-nootkatone quantitation by laser microdissection, ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry, and gas chromatography-mass spectrometry techniques.

    Science.gov (United States)

    Jaiswal, Yogini; Liang, Zhitao; Guo, Ping; Ho, Hing-Man; Chen, Hubiao; Zhao, Zhongzhen

    2014-07-23

    Cyperus rotundus L. is a plant species commonly found in both India and China. The caused destruction of this plant is of critical concern for agricultural produce. Nevertheless, it can serve as a potential source of the commercially important sesquiterpenoid (+)-nootkatone. The present work describes comparative metabolite profiling and (+)-nootkatone content determination in rhizome samples collected from these two countries. Laser dissected tissues, namely, the cortex, hypodermal fiber bundles, endodermis, amphivasal vascular bundles, and whole rhizomes were analyzed by ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Gas chromatography-mass spectrometry (GC-MS) analysis was used for profiling of essential oil constituents and quantitation of (+)-nootkatone. The content of (+)-nootkatone was found to be higher in samples from India (30.47 μg/10 g) compared to samples from China (21.72 μg/10 g). The method was validated as per International Conference on Harmonisation (ICH) guidelines (Q2 R1). The results from this study can be applied for quality control and efficient utilization of this terpenoid-rich plant for several applications in food-based industries. PMID:24938835

  12. A Novel Method for Quantitative Analysis of Oil Content in Polyurethane Fiber Waste by Pyrolysis Gas Chromatography-Mass Spectrometry%裂解气相色谱-质谱法测定氨纶废丝中油剂的含量

    Institute of Scientific and Technical Information of China (English)

    周静; 项超力; 刘亚辉; 曹代利; 陈铃; 唐劲松; 费长书

    2014-01-01

    Spandex is a polyurethane elastic fiber known for its wide range of applications. A large amount of spandex waste is generated during the production process, which needs to be recycled. Because the filature oil of the spandex waste would block the spin system during the production process, to control the content of filature oil before the spandex waste is recycled is necessary. In this paper, a new method to determine the residual oil content in spandex waste is established using the pyrolysis gas chromatography-mass spectrometry. The method is simple, efficient, and without any sample pretreatment, the method can provide accurate and reliable residual oil data for the cleaning work of spandex waste, especially for the industrial cleaning purpose.%氨纶是一种聚氨酯弹性纤维,应用领域广阔。在对氨纶生产过程中产生的大量废丝进行回收重复利用时,所添加的油剂会对甬道发生堵塞,因此在氨纶废丝回收之前需要对其进行清洗来控制油剂的含量。运用裂解气相色谱-质谱法( PY-GC/MS)建立了1种测试氨纶废丝中油剂残余含量的方法。方法简单快捷,无需任何样品前处理,为氨纶废丝的清洗工作,尤其是工业化清洗生产提供了准确可靠的数据。

  13. 在线热裂解-气相色谱/质谱联用技术分析葫芦巴净油的热裂解产物%Analysis of Pyrolysates from Fenugreek Absolute by On-Line Pyrolysis-Gas Chromatography/Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    叶荣飞; 程侠; 宋森川; 李峰; 黄飞; 任成龙; 宋化灿

    2015-01-01

    采用在线热裂解-气相色谱/质谱(Py-GC/MS)联用技术研究了氦气氛围中葫芦巴净油在300、400、500、600、700、800℃下的热裂解行为。结果表明:①在上述条件下共鉴定出86种裂解产物,主要是酯、酸、醇、烯烃类化合物;②裂解温度低于500℃时,检测到的成分基本相同;③裂解温度从600℃升至800℃,检测到危害性的苯系物种类增多、相对含量增大。此外,对葫芦巴净油裂解产物的致香机理和苯系物的形成机理进行了简单讨论。%Fenugreek absolute was pyrolyzed under helium atmospheres at 300,400,500,600,700 and 800 ℃,respectively.The pyrolysates were analyzed by on-line gas chromatography/mass spectrometry (GC/MS).The results showed that,first,eighty-six constituents were identified,and the major of the pyrolysates were esters,acids,alcohols and alkenes.Second,the pyrolysates were almost same at lower temperature (300~500 ℃).Third,more and more benzene derivates were identified with higher per-centage with increasing temperature (600~800 ℃).In addition,the flavor mechanism and the attribu-tion of benzene compounds were investigated.

  14. 搅拌棒磁子萃取-热脱附-气相色谱质谱联用分析葫芦巴浸膏的挥发性成分%Analysis of volatile components in fenugreek extract( Trigonella foenum-graecum L) by stir bar sorptive extraction-thermal desorption and gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    苏勇; 冒德寿; 曲荣芬; 李智宇; 毛多斌

    2012-01-01

    Volatile components from fenugreek extract were analyzed by using stir bar soptive extraction-thermal desoption and gas chromatography-mass spectrometry,and sixty-seven compounds were identified. 1,2- propylene glycol (38.83%), 2-phenylethyl2-phenylacetate (7.32%) ,2,4-dimethy1-1,3-dioxolane-2-methanol (5.33%), rinalool (3.67%) ,2-acetoxy- 1 -propanol (3.54%), isovaleric acid (2.75%) and 2-acetylfuran (2.06%) were the main components. In addition,the flavor mechanism was discussed. The research provided technological basis for quality control and exploit of fenugreek extract.%应用搅拌棒磁子萃取和热脱附系统,并结合气相色谱-质谱联用仪,测定了葫芦巴浸膏中的挥发性成分。从中鉴定出67个挥发性物质,主要成分为:l,2-丙二醇(38.83%)、苯乙酸苯乙酯(7.32%)、羟基丙酮丙二醇缩酮(5.33%)、芳樟醇(3.67%)、丙二醇单醋酸酯(3.54%)、异戊酸(2.75%)和2-乙酰基呋喃(2.06%)。此外,对葫芦巴浸膏的致香机理进行了探讨,研究为葫芦巴浸膏的品质控制和开发应用提供了技术依据。

  15. 裂解气相色谱-质谱法测定氨纶废丝中油剂的含量%A Novel Method for Quantitative Analysis of Oil Content in Polyurethane Fiber Waste by Pyrolysis Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    周静; 项超力; 刘亚辉; 曹代利; 陈铃; 唐劲松; 费长书

    2014-01-01

    氨纶是一种聚氨酯弹性纤维,应用领域广阔。在对氨纶生产过程中产生的大量废丝进行回收重复利用时,所添加的油剂会对甬道发生堵塞,因此在氨纶废丝回收之前需要对其进行清洗来控制油剂的含量。运用裂解气相色谱-质谱法( PY-GC/MS)建立了1种测试氨纶废丝中油剂残余含量的方法。方法简单快捷,无需任何样品前处理,为氨纶废丝的清洗工作,尤其是工业化清洗生产提供了准确可靠的数据。%Spandex is a polyurethane elastic fiber known for its wide range of applications. A large amount of spandex waste is generated during the production process, which needs to be recycled. Because the filature oil of the spandex waste would block the spin system during the production process, to control the content of filature oil before the spandex waste is recycled is necessary. In this paper, a new method to determine the residual oil content in spandex waste is established using the pyrolysis gas chromatography-mass spectrometry. The method is simple, efficient, and without any sample pretreatment, the method can provide accurate and reliable residual oil data for the cleaning work of spandex waste, especially for the industrial cleaning purpose.

  16. Profiling post-translational modifications of histones in neural differentiation of embryonic stem cells using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zheng, Shuzhen; Sun, Ming; Zhang, Kai; Gu, Junjie; Guo, Zhenchang; Tian, Shanshan; Zhai, Guijin; He, Xiwen; Jin, Ying; Zhang, Yukui

    2016-04-01

    The neural differentiation of embryonic stem cells (ESCs) is of great significance for understanding of the mechanism of diseases. Histone post-translational modifications (HPTMs) play a key role in the regulation of ESCs differentiation. Here, we combined the stable isotope chemical derivatization with nano-HPLC-mass spectrometry (MS) for comprehensive analysis and quantification of histone post-translational modifications (HPTMs) in mouse embryonic stem cells (mESCs) and neural progenitor cells (mNPCs) that was derived from ESCs. We identified 85 core HPTM sites in ESCs and 78HPTM sites in NPCs including some novel lysine modifications. Our quantitative analysis results further revealed the changes of HPTMs from ESCs to NPCs and suggested effect of combinational HPTMs in the differentiation. This study demonstrates that HPLC-MS-based quantitative proteomics has a considerable advantage on quantification of combinational PTMs and expands our understanding of HPTMs in the differentiation.

  17. Profiling of urinary amino-carboxylic metabolites by in-situ heptafluorobutyl chloroformate mediated sample preparation and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Hušek, Petr; Švagera, Zdeněk; Hanzlíková, Dagmar; Řimnáčová, Lucie; Zahradníčková, Helena; Opekarová, Iva; Šimek, Petr

    2016-04-22

    A novel 1,1,1,2,2,3,3-heptafluorobutyl chloroformate reagent (HFBCF) was examined for in-situ derivatization of amino-carboxylic metabolites in human urine. The arising reaction products exhibit greatly reduced polarity which facilitates combining the derivatization and liquid-liquid microextraction (LLME) from an aqueous urine into an isooctane phase and immediate gas chromatographic-mas spectrometric analysis (GC-MS). The sample preparation protocol is simple, proceeds without an alcohol excess and provides cleaner extracts than other urinary GC-MS based methods. Moreover, thiol metabolites bound in disulfide bonds can be released by reduction with tris(3-hydroxypropyl)phosphine (THP) prior to the developed derivatization and LLME step. In order to evaluate potential of the novel method for GC-MS metabolomics, reaction products of 153 urinary metabolites with HFBCF, particularly those possessing amino and carboxyl groups (56 amino acids and their conjugates, 84 organic acids, 9 biogenic amines, 4 other polar analytes) and two internal standards were investigated in detail by GC-MS and liquid chromatography-mass spectrometry (LC-MS). One hundred and twenty metabolites (78%) yielded a single product, 25 (16%) and 2 metabolites (2-methylcitrate, citrate) generated two and more derivatives. From the examined set, analytically applicable products of 5 metabolites were not detected; the derivatives of 3 metabolites were only suitable for LC-MS