WorldWideScience

Sample records for chromatography-mass spectrometry analysis

  1. VACUUM DISTILLATION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR THE ANALYSIS OF ENVIRONMENTAL SAMPLES

    Science.gov (United States)

    A procedure is presented that uses a vacuum distillation/gas chromatography/mass spectrometry system for analysis of problematic matrices of volatile organic compounds. The procedure compensates for matrix effects and provides both analytical results and confidence intervals from...

  2. Liquid chromatography mass spectrometry for analysis of microbial metabolites

    DEFF Research Database (Denmark)

    Klitgaard, Andreas

    are still to be discovered. The main analytical technique used to investigate production of products from these diverse organisms is liquid-chromatography coupled to mass spectrometry (LC-MS). With the development of new and improved analytical instrumentation for chemical analysis, the time needed...... to human health. Because of this, methods for detection and analysis of these compounds are vital. Estimates suggest that there are around 1.5 million different fungal species on Earth, dwarfing the number of plants estimated to 300,000, meaning that there potentially are many more interesting compounds...... to perform a single analytical run has decreased, while the amount of information obtained from each of these analytical runs has increased drastically. Consequently, the limiting step in chemical analysis of a microorganism is no longer the analytical run itself, but rather analysis of the resulting data...

  3. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry

    OpenAIRE

    Stepanov, Irina; Villalta, Peter W.; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S.

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified 8 different polycyclic aromatic hydrocarbons (PAH) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAH in smokeless tob...

  4. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  5. Analysis of estrogens and androgens in postmenopausal serum and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Qingqing; Bottalico, Lisa; Mesaros, Clementina; Blair, Ian A

    2015-07-01

    Liquid chromatography-selected reaction monitoring/mass spectrometry-based methodology has evolved to the point where accurate analyses of trace levels of estrogens and androgens in postmenopausal serum and plasma can be accomplished with high precision and accuracy. A suite of derivatization procedures has been developed, which together with modern mass spectrometry instrumentation provide investigators with robust and sensitive methodology. Pre-ionized derivatives are proving to be useful as they are not subject to suppression of the electrospray signal. Postmenopausal women with elevated plasma or serum estrogens are thought to be at increased risk for breast and endometrial cancer. Therefore, significant advances in risk assessment should be possible now that reliable methodology is available. It is also possible to conduct analyses of multiple estrogens in plasma or serum. Laboratories that are currently employing liquid chromatography/mass spectrometry methodology can now readily implement this strategy. This will help conserve important plasma and serum samples available in Biobanks, as it will be possible to conduct high sensitivity analyses using low initial sample volumes. Reported levels of both conjugated and non-conjugated estrogen metabolites are close to the limits of sensitivity of many assays to date, urging caution in the interpretation of these low values. The analysis of serum androgen precursors in postmenopausal women has not been conducted routinely in the past using liquid chromatography/mass spectrometry methodology. Integration of serum androgen levels into the panel of metabolites analyzed could provide additional information for assessing cancer risk and should be included in the future.

  6. Gas chromatography-mass spectrometry analysis of various organic extracts ofMerremia borneensisfrom Sabah

    Institute of Scientific and Technical Information of China (English)

    M Amzad Hossain; Muhammad Dawood Shah; Mahyar Sakari

    2011-01-01

    Objective:To analyse the chemical composition of different extracts ofMerremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).Methods: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts ofM. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol. Results: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further theM. borneensisleaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.Conclusions: The suitable extracts for respective compounds can be chosen on the basis of aboveGC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extractsM. borneensis might have some ecological significance.

  7. Use, history, and liquid chromatography/mass spectrometry chemical analysis of Aconitum

    Directory of Open Access Journals (Sweden)

    Mohamed El-Shazly

    2016-01-01

    Full Text Available Aconitum and its products have been used in Asia for centuries to treat various ailments, including arthritis, gout, cancer, and inflammation. In general, their preparations and dispensing have been restricted to qualified folk medicine healers due to their low safety index and reported toxicity. In the past few decades, official guidelines have been introduced in Asian pharmacopeias to control Aconitum herbal products. However, these guidelines were based on primitive analytical techniques for the determination of the whole Aconitum alkaloids and were unable to distinguish between toxic and nontoxic components. Recent advances in analytical techniques, especially high performance liquid chromatography (HPLC and electrophoresis coupled with highly sensitive detectors, allowed rapid and accurate determination of Aconitum secondary metabolites. Reports focusing on liquid chromatography/mass spectrometry analysis of Aconitum and its herbal products are discussed in the current review. This review can be used by the health regulatory authorities for updating pharmacopeial guidelines of Aconitum and its herbal products.

  8. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel; Borek, Theodore Thaddeus, III

    2010-09-01

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief

  9. ANALYSIS OF TRACE-LEVEL ORGANIC COMBUSTION PROCESS EMISSIONS USING NOVEL MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY PROCEDURES

    Science.gov (United States)

    The paper discusses the analysis of trace-level organic combustion process emissions using novel multidimensional gas chromatography-mass spectrometry (MDGC-MS) procedures. It outlines the application of the technique through the analyses of various incinerator effluent and produ...

  10. Comparative urine analysis by liquid chromatography-mass spectrometry and multivariate statistics : Method development, evaluation, and application to proteinuria

    NARCIS (Netherlands)

    Kemperman, Ramses F. J.; Horvatovich, Peter L.; Hoekman, Berend; Reijmers, Theo H.; Muskiet, Frits A. J.; Bischoff, Rainer

    2007-01-01

    We describe a platform for the comparative profiling of urine using reversed-phase liquid chromatography-mass spectrometry (LC-MS) and multivariate statistical data analysis. Urinary compounds were separated by gradient elution and subsequently detected by electrospray Ion-Trap MS. The lower limit o

  11. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  12. In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Cabane, M.; Coll, P.; Navarro-Gonzalez, R.; Mahaffy, P. R.

    2005-01-01

    One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

  13. Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.

    Science.gov (United States)

    Wang, Jian

    2009-01-01

    Macrolides are a group of antibiotics that have been widely used in human medical and veterinary practices. Analysis of macrolides and related compounds in food, biological, and environmental matrices continue to be the focus of scientists for the reasons of food safety, pharmacokinetic studies, and environmental concerns. This article presents an overview on the primary biological properties of macrolides and their associated analytical issues, including extraction, liquid chromatography-mass spectrometry (LC-MS), method validation, and measurement uncertainty. The main techniques that have been used to extract macrolides from various matrices are solid-phase extraction and liquid-liquid extraction. Conventional liquid chromatography (LC) with C18 columns plays a dominant role for the determination of macrolides, whereas ultra-performance liquid chromatography (UPLC) along with sub-2 microm particle C18 columns reduces run time and improves sensitivity. Mass spectrometry (MS), serving as a universal detection technique, has replaced ultraviolet (UV), fluorometric, and electrochemical detection for multi-macrolide analysis. The triple-quadrupole (QqQ), quadrupole ion trap (QIT), triple-quadrupole linear ion trap, time-of-flight (TOF), and quadrupole time-of-flight (QqTOF) mass spectrometers are current choices for the determination of macrolides, including quantification, confirmation, identification of their degradation products or metabolites, and structural elucidation. LC or UPLC coupled to a triple-quadrupole mass spectrometer operated in the multiple-reaction monitoring (MRM) mode (LC/MS/MS) is the first choice for quantification. UPLC-TOF or UPLC-QqTOF has been recognized as an emerging technique for accurate mass measurement and unequivocal identification of macrolides and their related compounds.

  14. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-03-23

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol.

  15. Liquid chromatography/mass spectrometry analysis of exhaled leukotriene B4 in asthmatic children

    Directory of Open Access Journals (Sweden)

    Barnes Peter J

    2005-10-01

    Full Text Available Abstract Background The role of leukotriene (LT B4, a potent inflammatory mediator, in atopic asthmatic and atopic nonasthmatic children is largely unknown. The lack of a gold standard technique for measuring LTB4 in exhaled breath condensate (EBC has hampered its quantitative assessment in this biological fluid. We sought to measure LTB4 in EBC in atopic asthmatic children and atopic nonasthmatic children. Exhaled nitric oxide (NO was measured as an independent marker of airway inflammation. Methods Fifteen healthy children, 20 atopic nonasthmatic children, 25 steroid-naïve atopic asthmatic children, and 22 atopic asthmatic children receiving inhaled corticosteroids were studied. The study design was of cross-sectional type. Exhaled LTB4 concentrations were measured using liquid chromatography/mass spectrometry-mass spectrometry (LC/MS/MS with a triple quadrupole mass spectrometer. Exhaled NO was measured by chemiluminescence with a single breath on-line method. LTB4 values were expressed as the total amount (in pg of eicosanoid expired in the 15-minute breath test. Kruskal-Wallis test was used to compare groups. Results Compared with healthy children [87.5 (82.5–102.5 pg, median and interquartile range], exhaled LTB4 was increased in steroid-naïve atopic asthmatic [255.1 (175.0–314.7 pg, p 4 than steroid-naïve asthmatics [125.0 (25.0–245.0 pg vs 255.1 (175.0–314.7 pg, p Conclusion In contrast to exhaled NO concentrations, exhaled LTB4 values are selectively elevated in steroid-naïve atopic asthmatic children, but not in atopic nonasthmatic children. Although placebo control studies are warranted, inhaled corticosteroids seem to reduce exhaled LTB4 in asthmatic children. LC/MS/MS analysis of exhaled LTB4 might provide a non-invasive, sensitive, and quantitative method for airway inflammation assessment in asthmatic children.

  16. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Stepanov, Irina; Villalta, Peter W; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified eight different polycyclic aromatic hydrocarbons (PAHs) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAHs in smokeless tobacco after a simple two-step extraction and purification procedure. The method produced coefficients of variation under 10% for most PAHs. The limits of quantitation for different PAHs varied between 0.3 and 11 ng/g tobacco, starting with a 300 mg sample. The recovery of the stable isotope-labeled internal standards averaged 87%. The method was applied to analysis of 23 moist snuff samples that included various flavors of the most popular U.S. moist snuff brands, as well as 17 samples representing the currently marketed brands of spit-free tobacco pouches, a relatively new type of smokeless tobacco. The sum of all detected PAHs in conventional moist snuff averaged 11.6 (+/-3.7) microg/g dry weight; 20% of this amount was comprised of carcinogenic PAHs. The levels of PAHs in new spit-free tobacco products were much lower than those in moist snuff; the sum of all detected PAHs averaged 1.3 (+/-0.28) microg/g dry weight. Our findings render PAHs one of the most prevalent groups of carcinogens in smokeless tobacco. Urgent measures are required from the U.S. tobacco industry to modify manufacturing processes so that the levels of these toxicants and carcinogens in U.S. moist snuff are greatly reduced.

  17. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate.

    Science.gov (United States)

    Lee, E A; Zimmerman, L R; Bhullar, B S; Thurman, E M

    2002-10-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solid-phase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 microg/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 microg/ L, relative standard deviation +/- 15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'EUSA gave a false positive rate of 18% between 0.1 and 1.0 microg/L and a false positive rate of only 1% above 1.0 microg/L The relative standard deviation was +/- 20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  18. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate

    Science.gov (United States)

    Lee, E.A.; Zimmerman, L.R.; Bhullar, B.S.; Thurman, E.M.

    2002-01-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solidphase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 ??g/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 ??g/L, relative standard deviation ??15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'ELISA gave a false positive rate of 18% between 0.1 and 1.0 ??g/L and a false positive rate of only 1% above 1.0 ??g/L. The relative standard deviation was ??20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  19. Analysis of acetylene in blood and urine using cryogenic gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kashiwagi, Masayuki; Hara, Kenji; Fujii, Hiroshi; Kageura, Mitsuyoshi; Takamoto, Mutsuo; Matsusue, Aya; Sugimura, Tomoko; Kubo, Shin-ichi

    2009-09-01

    A method for quantitative analysis of acetylene in blood and urine samples was investigated. Using cryogenic gas chromatography-mass spectrometry (GC-MS), acetylene was measured with isobutane as the internal standard in the headspace method, which revealed a linear response over the entire composite range with an excellent correlation coefficient, both in blood (R = 0.9968, range = 5.39-43.1 microg/ml) and urine (R = 0.9972, range = 2.16-10.8 microg/ml). The coefficients of variation (CV) for blood ranged from 2.62 to 11.6% for intra-day and 4.55 to 10.4% for inter-day. The CV for urine ranged from 2.38 to 3.10% for intra-day and 4.83 to 11.0% for inter-day. The recovery rate as an index of accuracy ranged from 83 to 111%. The present method showed good reliability, and is also simple and rapid. In actual samples from a charred cadaver due to acetylene explosion, the measured concentrations of acetylene by this method were 21.5 microg/ml for femoral vein blood, 17.9 microg/ml for right atrial blood, 25.5 microg/ml for left atrial blood and 7.49 microg/ml for urine. Quantification of acetylene provides important information, because the acetylene concentration is a vital reaction or sign. For example, when acetylene is filled in a closed space and then explodes, in antemortem explosion, the blood acetylene concentration of the cadaver might be significant. On the other hand, in postmortem explosion, acetylene is not detected in blood. Furthermore, when several victims are involved in one explosion, comparison of the sample concentrations can also provide useful information to establish the conditions at the accident scene; therefore, the present method is useful in forensics.

  20. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul; Haque; Rahima; Khatun; Zahira; Yaakob

    2015-01-01

    Objective:To evaluate the antibacterial activity of essential oil from Trigonella foenumgraecum seeds powder,and identify the compounds from the extracted oil.Methods:The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor.Seven strains of bacteria were used to test antibacterial activity of the extract.The activity against bacteria was tested by disk diffusion method using Whatman No.1filter paper.Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector.Results:The hydrodistillation of seeds powder yielded 0.285%(v/w)of oil.Disk diffusion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains.The inhibition zone ranged from(8±0)mm to(15.0±0.7)mm depending on microbial strains.Gas chromatography mass spectrometry analysis showed14 different compounds.The total compounds represented 80.96%of the oil.Conclusions:The antibacterial activity is due to the effects of different biological active compounds present in the extract.Identification of the compounds may help to develop new effective antimicrobial agent(s).Further researches on purification,characterization and toxicology of the active compounds are needed.

  1. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul Haque; Rahima Khatun; Zahira Yaakob

    2015-01-01

    Objective: To evaluate the antibacterial activity of essential oil from Trigonella foenum-graecum seeds powder, and identify the compounds from the extracted oil. Methods: The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor. Seven strains of bacteria were used to test antibacterial activity of the extract. The activity against bacteria was tested by disk diffusion method using Whatman No. 1 filter paper. Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector. Results: The hydrodistillation of seeds powder yielded 0.285%(v/w) of oil. Disk diffu-sion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains. The inhibition zone ranged from (8 ± 0) mm to (15.0 ± 0.7) mm depending on microbial strains. Gas chromatography mass spectrometry analysis showed 14 different compounds. The total compounds represented 80.96%of the oil. Conclusions: The antibacterial activity is due to the effects of different biological active compounds present in the extract. Identification of the compounds may help to develop new effective antimicrobial agent(s). Further researches on purification, characterization and toxicology of the active compounds are needed.

  2. Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Beach, Daniel G; Melanson, Jeremy E; Purves, Randy W

    2015-03-01

    The analysis of paralytic shellfish toxins (PSTs) by liquid chromatography-mass spectrometry remains a challenge because of their high polarity, large number of analogues and the complex matrix in which they occur. Here we investigate the potential utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) as a gas-phase ion separation tool for analysis of PSTs by mass spectrometry. We investigate the separation of PSTs using FAIMS with two divergent goals: using FAIMS as a primary separation tool for rapid screening by electrospray ionization (ESI)-FAIMS-MS or combined with LC in a multidimensional LC-ESI-FAIMS-MS separation. First, a survey of the parameters that affect the sensitivity and selectivity of PST analysis by FAIMS was carried out using ESI-FAIMS-MS. In particular, the use of acetonitrile as a gas additive in the carrier gas flow offered good separation of all PST epimeric pairs. A second set of FAIMS conditions was also identified, which focussed PSTs to a relatively narrow CV range allowing development of an LC-ESI-FAIMS-MS method for analysis of PST toxins in complex mussel tissue extracts. The quantitative capabilities of this method were evaluated by analysing a PST containing mussel tissue matrix material. Results compared favourably with analysis by an established LC-post-column oxidation-fluorescence method with recoveries ranging from 70 to 106%, although sensitivity was somewhat reduced. The current work represents the first successful separation of PST isomers using ion mobility and shows the promise of FAIMS as a tool for analysis of algal biotoxins in complex samples and outlines some critical requirements for its future improvement.

  3. Analysis of psilocybin and psilocin in Psilocybe subcubensis Guzmán by ion mobility spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W

    1999-01-11

    A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.

  4. Multiclass mycotoxin analysis in food, environmental and biological matrices with chromatography/mass spectrometry.

    Science.gov (United States)

    Capriotti, Anna Laura; Caruso, Giuseppe; Cavaliere, Chiara; Foglia, Patrizia; Samperi, Roberto; Laganà, Aldo

    2012-01-01

    Mold metabolites that can elicit deleterious effects on other organisms are classified as mycotoxins. Human exposure to mycotoxins occurs mostly through the intake of contaminated agricultural products or residues due to carry over or metabolite products in foods of animal origin such as milk and eggs, but can also occur by dermal contact and inhalation. Mycotoxins contained in moldy foods, but also in damp interiors, can cause diseases in humans and animals. Nephropathy, various types of cancer, alimentary toxic aleukia, hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders are the most common diseases that can be related to mycotoxicosis. The absence or presence of mold infestation and its propagation are seldom correlated with mycotoxin presence. Mycotoxins must be determined directly, and suitable analytical methods are necessary. Hundreds of mycotoxins have been recognized, but only for a few of them, and in a restricted number of utilities, a maximum acceptable level has been regulated by law. However, mycotoxins seldom develop alone; more often various types and/or classes form in the same substrate. The co-occurrence might render the individual mycotoxin tolerance dose irrelevant, and therefore the mere presence of multiple mycotoxins should be considered a risk factor. The advantage of chromatography/mass spectrometry (MS) is that many compounds can be determined and confirmed in one analysis. This review illustrates the state-of-the-art of mycotoxin MS-based analytical methods for multiclass, multianalyte determination in all the matrices in which they appear. A chapter is devoted to the history of the long-standing coexistence and interaction among humans, domestic animals and mycotoxicosis, and the history of the discovery of mycotoxins. Quality assurance, although this topic relates to analytical chemistry in general, has been also examined for mycotoxin analysis as a preliminary to the systematic literature excursus

  5. Gas Chromatography-Mass Spectrometry Based Isotopic Abundance Ratio Analysis of Biofield Energy Treated Methyl-2-napthylether (Nerolin)

    OpenAIRE

    2016-01-01

    Methyl-2-napthylether (nerolin) is an organic compound and has the applications in pharmaceutical, and perfume industry. The stable isotope ratio analysis is increasing importance in various field of scientific research. The objective of the current study was to evaluate the effect of the biofield energy treatment on the isotopic abundance ratios of PM+1/PM(2H/1H or 13C/12C or 17O/16O) and PM+2/PM (18O/16O) in nerolin using the gas chromatography-mass spectrometry (GC-MS). The compound neroli...

  6. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  7. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults.

  8. [Analysis of volatile constituents in leaves of three cypress species by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Hao, Dejun; Zhang, Yonghui; Dai, Huaguo; Wang, Yan

    2006-03-01

    Volatile oils in leaves of three cypress species were extracted by hydrodistillation method and analyzed by gas chromatography/mass spectrometry. Sixty-four constituents were separated and identified. The majority of the components were found to be monoterpenes and sesquiterpenes. There were 33, 37, 37 compounds in the oils of leaves of Sabina chinensis (L.) Ant, Cupressus lusitanica 'zhongshan' Mill and Sabina chinensis (L.) Ant. Cv. Kaizuca, respectively. Fourteen compounds were common to them, which were thujene, alpha-pinene, camphene, sabinene, beta-myrcene, alpha-terpinene, gamma-terpinene, alpha-terpinolene, bornyl acetate, beta-elemene, alpha-amorphene, germacrene D, delta-cadinene and elemol. In addition, each species had particular compounds. The main components were found to be: sabinene (20.99%), limonene (19.78%) and bornyl acetate (11.68%) for Sabina chinensis (L.) Ant; alpha-pinene (10.39%), sabinene (11.19%) and delta-3-carene (8.88%) for Cupressus lusitanica 'zhongshan' Mill; limonene (24.56%), beta-myrcene (8.04%) for Sabina chinensis (L.) Ant. Cv. Kaizuca.

  9. Analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Ramírez-Maya, Erika; Alvarado-Suárez, Luís Angel

    2009-04-01

    A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography-mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109-1.323 microg/mL for capsaicin and 0.107-1.713 microg/mL for dihydrocapsaicin with correlation coefficient up to r=0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0-25 459 microg/g) and dihydrocapsaicin (93-1 130 microg/g) was found in the pepper and pepper sauces samples (4.3-717.3 and 1.0-134.8 microg/g), respectively.

  10. Analysis of the venom of the Sydney funnel-web spider, Atrax robustus using gas chromatography mass spectrometry.

    Science.gov (United States)

    Duffield, P H; Duffield, A M; Carroll, P R; Morgans, D

    1979-03-01

    Thirteen compounds have been identified using gas chromatography mass spectrometry in the venom of the Sydney funnel-web spider, Atrax robustus. The compounds were identified as their trimethylsilyl or pentafluoropropionate derivatives and were citric acid, lactic acid, phosphoric acid, glycerol, urea, glucose, gamma-aminobutyric acid, glycine, spermidine, spermine, tyramine and octopamine. Female venom contained trace quantities of 5-methyoxytryptamine which was not detected in male venom. Quantitative determination of tyramine and octopamine was achieved using chemical ionization (CH4) gas chromatography mass spectrometry and deuterated internal standards.

  11. Headspace solvent microextraction-gas chromatography-mass spectrometry for the analysis of volatile compounds from Foeniculum vulgare Mill.

    Science.gov (United States)

    Fang, Lianghua; Qi, Meiling; Li, Ting; Shao, Qinglong; Fu, Ruonong

    2006-06-07

    A novel and rapid headspace solvent microextraction followed by gas chromatography-mass spectrometry (HSME-GC-MS) for the analysis of the volatile compounds of Foeniculum vulgare Mill is described. HSME parameters including extracting solvent, extraction temperature and time, headspace volume and particle size were optimized. As a result, benzyl alcohol was finally used for the extraction at 70 degrees C for 20 min with headspace volume of 12.1 ml and particle size of 120 mesh. Under the determined conditions, the powered samples of Foeniculum vulgare Mill were directly applied for the analysis. A comparison of HSME-GC-MS, solid phase microextraction (SPME)-GC-MS and steam distillation (SD)-GC-MS methods was made and showed that the HSME-GC-MS method was simple, inexpensive and effective and can be used for the analysis of volatile compounds in traditional Chinese medicines (TCMs).

  12. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    OpenAIRE

    Yong-Gang Xia; Bing-You Yang; Jun Liang; Qi Yang; Di Wang; Hai-Xue Kuang

    2014-01-01

    This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS). The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified b...

  13. Carbohydrate analysis of hemicelluloses by gas chromatography-mass spectrometry of acteylated methyl glycosides

    DEFF Research Database (Denmark)

    Sárossy, Zsuzsa; Plackett, David; Egsgaard, Helge

    2012-01-01

    A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C...

  14. Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuan-fan YANG; Shen-ru CHEN; Hui NI; Xing-qian YE

    2008-01-01

    Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl ace tate extraction fol-lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods.

  15. Gas Chromatography-Mass Spectrometry Analysis of Constituent Oil from Lingzhi or Reishi Medicinal Mushroom, Ganoderma lucidum (Agaricomycetes), from Nigeria.

    Science.gov (United States)

    Ohiri, Reginald Chibueze; Bassey, Essien Eka

    2016-01-01

    Gas chromatography-mass spectrometry analysis of constituent oil from dried Ganoderma lucidum was carried out. Fresh G. lucidum obtained from its natural environment was thoroughly washed with distilled water and air-dried for 2 weeks and the component oils were extracted and analyzed. Four predominant components identified were pentadecanoic acid, 14-methyl-ester (retention time [RT] = 19.752 minutes; percentage total = 25.489), 9,12-octadecadienoic acid (Z,Z)- (RT = 21.629 minutes and 21.663 minutes; percentage total = 25.054), n-hexadecanoic acid (RT = 20.153 minutes; percentage total = 24.275), and 9-octadecenoic acid (Z)-, methyl ester (RT = 21.297 minutes; percentage total = 13.027). The two minor oils identified were 9,12-octadecadienoic acid, methyl ester, (E,E)- and octadecanoic acid, methyl ester (RT = 21.246 minutes and 21.503 minutes; percentage total = 7.057 and 5.097, respectively).

  16. The analysis of tire rubber traces collected after braking incidents using Pyrolysis-GasChromatography/Mass Spectrometry.

    Science.gov (United States)

    Sarkissian, Garry

    2007-09-01

    Automobile tire marks can routinely be found at the scenes of crime, particularly hit-and-run accidents and are left on road surfaces because of sudden braking or the wheels spinning. The tire marks are left due to the friction between the tire rubber and the solid road surface, and do not always demonstrate the tire tread pattern. However, the tire mark will contain traces of the tire. In this study, Pyrolysis Gas Chromatography/Mass Spectrometry was used to analyze 12 tires from different manufacturer's and their traces collected after braking incidents. Tire marks were left on a conglomerate road surface with sudden braking. The samples were pyrolysed without removal of contaminant in a micro-furnace type pyrolyser. Quantitative and qualitative analysis were performed on all the samples. All 12 samples were distinguished from each other. Each of the tire traces were identified as coming from there original source.

  17. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From t

  18. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing additi

  19. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  20. Direct analysis of intact glycidyl fatty acid esters in edible oils using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    van Steenbergen, H.; Hrnčiřík, K.; Ermacora, A.; de Koning, S.; Janssen, H.-G.

    2013-01-01

    Glycidyl esters (GE), fatty acid esters of glycidol, are process contaminants formed during edible oil processing. A novel direct method for the determination of intact GE in oils and fats based on gas chromatography-mass spectrometry (GC-MS) is presented. The method consists of a simple extraction

  1. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    Science.gov (United States)

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  2. Analysis of swainsonine and swainsonine N-oxide as trimethylsilyl derivatives by Liquid Chromatography-Mass Spectrometry and their relative occurrence in plants toxic to livestock

    Science.gov (United States)

    A liquid chromatography-mass spectrometry method was developed for the analysis of the indolizidine alkaloid swainsonine and its N-oxide. The method is based on a one step solvent partitioning extraction procedure followed by trimethylsilylation of the dried extract and subsequent detection and qua...

  3. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yong-Gang Xia

    2014-01-01

    Full Text Available This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS. The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method.

  4. Targeted Chiral Analysis of Bioactive Arachidonic Acid Metabolites Using Liquid-Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Clementina Mesaros

    2012-04-01

    Full Text Available A complex structurally diverse series of eicosanoids arises from the metabolism of arachidonic acid. The metabolic profile is further complicated by the enantioselectivity of eicosanoid formation and the variety of regioisomers that arise. In order to investigate the metabolism of arachidonic acid in vitro or in vivo, targeted methods are advantageous in order to distinguish between the complex isomeric mixtures that can arise by different metabolic pathways. Over the last several years this targeted approach has become more popular, although there are still relatively few examples where chiral targeted approaches have been employed to directly analyze complex enantiomeric mixtures. To efficiently conduct targeted eicosanoid analyses, LC separations are coupled with collision induced dissociation (CID and tandem mass spectrometry (MS/MS. Product ion profiles are often diagnostic for particular regioisomers. The highest sensitivity that can be achieved involves the use of selected reaction monitoring/mass spectrometry (SRM/MS; whereas the highest specificity is obtained with an SRM transitions between an intense parent ion, which contains the intact molecule (M and a structurally significant product ion. This review article provides an overview of arachidonic acid metabolism and targeted chiral methods that have been utilized for the analysis of the structurally diverse eicosanoids that arise.

  5. Assessment of oil weathering by gas chromatography-mass spectrometry, time warping and principal component analysis

    DEFF Research Database (Denmark)

    Malmquist, Linus M.V.; Olsen, Rasmus R.; Hansen, Asger B.

    2007-01-01

    Detailed characterization and understanding of oil weathering at the molecular level is an essential part of tiered approaches for forensic oil spill identification, for risk assessment of terrestrial and marine oil spills, and for evaluating effects of bioremediation initiatives. Here......, a chemometricbased method is applied to data from two in vitro experiments in order to distinguish the effects of evaporation and dissolution processes on oil composition. The potential of the method for obtaining detailed chemical information of the effects from evaporation and dissolution processes, to determine...... weathering state and to distinguish between various weathering processes is investigated and discussed. The method is based on comprehensive and objective chromatographic data processing followed by principal component analysis (PCA) of concatenated sections of gas chromatography–mass spectrometry...

  6. Trace analysis in complex mixtures using a high-component filtering strategy with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Hui; Wang, Shao-Qing; Liu, Ying; Luo, Li-Ping; Liu, Peng; Qi, Lian-Wen; Li, Ping

    2012-11-01

    Trace constituents are widely present in complex mixtures, and trace analysis is challenging because of the unpredictable matrix. In this work, a high-component filtering strategy was developed for improved analysis of trace constituents in complex sample by liquid chromatography-mass spectrometry (LC-MS). Using a specifically designed chromatographic apparatus, the high-abundant fractions were filtered prior to LC-MS analysis. The samples complexity was reduced and the sample-loading amount for the rest low-level fractions can be considerably increased. The application of this approach was illustrated with an analytically challenging sample, a traditional Chinese herbal medicine named Compound Danshen Sample. We observed that the loss rate for 12 analytes during the filtering procedure ranged from 6.54 to 26.11%, but showed a stable repeatability with RSDanalysis, allowing six low compounds that cannot be quantified by the traditional methods to be tested by the filtering method. It can be predicted that the qualitative and quantitative trace analysis will be greatly improved when the loading samples is increased resulting from the filtration of high-level targets. The proposed strategy is promising to monitor trace constituents in diverse complex mixtures in the analytical field of pharmaceutics, metabonomics and environments.

  7. An improved, automated whole air sampler and gas chromatography mass spectrometry analysis system for volatile organic compounds in the atmosphere

    Science.gov (United States)

    Lerner, Brian M.; Gilman, Jessica B.; Aikin, Kenneth C.; Atlas, Elliot L.; Goldan, Paul D.; Graus, Martin; Hendershot, Roger; Isaacman-VanWertz, Gabriel A.; Koss, Abigail; Kuster, William C.; Lueb, Richard A.; McLaughlin, Richard J.; Peischl, Jeff; Sueper, Donna; Ryerson, Thomas B.; Tokarek, Travis W.; Warneke, Carsten; Yuan, Bin; de Gouw, Joost A.

    2017-01-01

    Volatile organic compounds were quantified during two aircraft-based field campaigns using highly automated, whole air samplers with expedited post-flight analysis via a new custom-built, field-deployable gas chromatography-mass spectrometry instrument. During flight, air samples were pressurized with a stainless steel bellows compressor into electropolished stainless steel canisters. The air samples were analyzed using a novel gas chromatograph system designed specifically for field use which eliminates the need for liquid nitrogen. Instead, a Stirling cooler is used for cryogenic sample pre-concentration at temperatures as low as -165 °C. The analysis system was fully automated on a 20 min cycle to allow for unattended processing of an entire flight of 72 sample canisters within 30 h, thereby reducing typical sample residence times in the canisters to less than 3 days. The new analytical system is capable of quantifying a wide suite of C2 to C10 organic compounds at part-per-trillion sensitivity. This paper describes the sampling and analysis systems, along with the data analysis procedures which include a new peak-fitting software package for rapid chromatographic data reduction. Instrument sensitivities, uncertainties and system artifacts are presented for 35 trace gas species in canister samples. Comparisons of reported mixing ratios from each field campaign with measurements from other instruments are also presented.

  8. [Serum metabolomics analysis on benign prostate hyperplasia in mice based on liquid chromatography-mass spectrometry].

    Science.gov (United States)

    Geng, Yue; Sun, Fengxia; Ma, Yu; Deng, Ligang; Lü, Jianyun; Li, Teng; Wang, Congcong

    2014-12-01

    Benign prostatic hyperplasia (BPH) increasingly becomes a common factor affecting the quality of life of aging men. Its pathogenesis has not yet been fully elucidated. Ultra-high pressure liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) was employed to detect the changes of serum metabolites in normal mice, benign prostatic hyperplasia model mice and BPH model mice with finasteride intervention. The serum metabolite profiles of the three groups of mice were analyzed. Partial least squares-discriminant analysis (PLS-DA) was used for group differentiation and biomarker selection. The results showed good distinction among the three groups of mice serum metabolite spectra. Three potential biomarkers, 1-hexadecanoyl-SN-glycero-3-phosphocholine, 1-O-hexadecyl-2-O-acetyl-sn-glyceryl-3-phosphorylcholine and (Z)-13-docosenamide, were discovered and identified. They all indicated the occurrence of benign prostatic hypertrophy is closely related to the disorders of lipid metabolism. Coinpared with the control group, the contents of the first two substances were significantly increased in the serum of BPH model mice, and significantly decreased after intervened by finasteride. The contents of (Z)-13-docosenamide decreased significantly in the serum of model group, and increased after intervened by finasteride. Compared with the control group, the contents of three biomarkers in finasteride group did not recover completely and had significant differences. This study is conductive to open new avenues of diagnosis and medical treatment for BPH.

  9. Systematic Optimization of Long Gradient Chromatography Mass Spectrometry for Deep Analysis of Brain Proteome

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong; Yang, Yanling; Li, Yuxin; Bai, Bing; Wang, Xusheng; Tan, Haiyan; Liu, Tao; Beach, Thomas G.; Peng, Junmun; Wu, Zhiping

    2015-02-06

    Development of high resolution liquid chromatography (LC) is essential for improving the sensitivity and throughput of mass spectrometry (MS)-based proteomics. Here we present systematic optimization of a long gradient LC-MS/MS platform to enhance protein identification from a complex mixture. The platform employed an in-house fabricated, reverse phase column (100 μm x 150 cm) coupled with Q Exactive MS. The column was capable of achieving a peak capacity of approximately 700 in a 720 min gradient of 10-45% acetonitrile. The optimal loading level was about 6 micrograms of peptides, although the column allowed loading as many as 20 micrograms. Gas phase fractionation of peptide ions further increased the number of peptide identification by ~10%. Moreover, the combination of basic pH LC pre-fractionation with the long gradient LC-MS/MS platform enabled the identification of 96,127 peptides and 10,544 proteins at 1% protein false discovery rate in a postmortem brain sample of Alzheimer’s disease. As deep RNA sequencing of the same specimen suggested that ~16,000 genes were expressed, current analysis covered more than 60% of the expressed proteome. Further improvement strategies of the LC/LC-MS/MS platform were also discussed.

  10. Serum metabolomics study and eicosanoid analysis of childhood atopic dermatitis based on liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, Yan; Chen, Guoyou; Liu, Xinyu; Shao, Yaping; Gao, Peng; Xin, Chenchen; Cui, Zhenze; Zhao, Xinjie; Xu, Guowang

    2014-12-05

    Atopic dermatitis (AD) is the most common inflammatory skin disease in children. In the study, ultra high performance liquid chromatography-mass spectrometry was used to investigate serum metabolic abnormalities of AD children. Two batch fasting sera were collected from AD children and healthy control; one of them was for nontargeted metabolomics analysis, the other for targeted eicosanoids analysis. AD children were divided into high immunoglobulin E (IgE) group and normal IgE group. On the basis of the two analysis approaches, it was found that the differential metabolites of AD, leukotriene B4, prostaglandins, conjugated bile acids, etc., were associated with inflammatory response and bile acids metabolism. Carnitines, free fatty acids, lactic acid, etc., increased in the AD group with high IgE, which revealed energy metabolism disorder. Amino acid metabolic abnormalities and increased levels of Cytochrome P450 epoxygenase metabolites were found in the AD group with normal IgE. The results provided a new perspective to understand the mechanism and find potential biomarkers of AD and may provide a new reference for personalized treatment.

  11. Evaluation of beer deterioration by gas chromatography-mass spectrometry/multivariate analysis: a rapid tool for assessing beer composition.

    Science.gov (United States)

    Rodrigues, João A; Barros, António S; Carvalho, Beatriz; Brandão, Tiago; Gil, Ana M; Ferreira, António C Silva

    2011-02-18

    Beer stability is a major concern for the brewing industry, as beer characteristics may be subject to significant changes during storage. This paper describes a novel non-targeted methodology for monitoring the chemical changes occurring in a lager beer exposed to accelerated aging (induced by thermal treatment: 18 days at 45 °C), using gas chromatography-mass spectrometry in tandem with multivariate analysis (GC-MS/MVA). Optimization of the chromatographic run was performed, achieving a threefold reduction of the chromatographic time. Although losing optimum resolution, rapid GC runs showed similar chromatographic profiles and semi-quantitative ability to characterize volatile compounds. To evaluate the variations on the global volatile signature (chromatographic profile and m/z pattern of fragmentation in each scan) of beer during thermal deterioration, a non-supervised multivariate analysis method, Principal Component Analysis (PCA), was applied to the GC-MS data. This methodology allowed not only the rapid identification of the degree of deterioration affecting beer, but also the identification of specific compounds of relevance to the thermal deterioration process of beer, both well established markers such as 5-hydroxymethylfufural (5-HMF), furfural and diethyl succinate, as well as other compounds, to our knowledge, newly correlated to beer aging.

  12. Fuzzy C-means clustering for chromatographic fingerprints analysis: A gas chromatography-mass spectrometry case study.

    Science.gov (United States)

    Parastar, Hadi; Bazrafshan, Alisina

    2016-03-18

    Fuzzy C-means clustering (FCM) is proposed as a promising method for the clustering of chromatographic fingerprints of complex samples, such as essential oils. As an example, secondary metabolites of 14 citrus leaves samples are extracted and analyzed by gas chromatography-mass spectrometry (GC-MS). The obtained chromatographic fingerprints are divided to desired number of chromatographic regions. Owing to the fact that chromatographic problems, such as elution time shift and peak overlap can significantly affect the clustering results, therefore, each chromatographic region is analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) to address these problems. Then, the resolved elution profiles are used to make a new data matrix based on peak areas of pure components to cluster by FCM. The FCM clustering parameters (i.e., fuzziness coefficient and number of cluster) are optimized by two different methods of partial least squares (PLS) as a conventional method and minimization of FCM objective function as our new idea. The results showed that minimization of FCM objective function is an easier and better way to optimize FCM clustering parameters. Then, the optimized FCM clustering algorithm is used to cluster samples and variables to figure out the similarities and dissimilarities among samples and to find discriminant secondary metabolites in each cluster (chemotype). Finally, the FCM clustering results are compared with those of principal component analysis (PCA), hierarchical cluster analysis (HCA) and Kohonon maps. The results confirmed the outperformance of FCM over the frequently used clustering algorithms.

  13. Simultaneous analysis of hemoglobin adducts of acrylamide and glycidamide by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pérez, H L; Cheong, H K; Yang, J S; Osterman-Golkar, S

    1999-10-01

    Acrylamide (AA) is a carcinogen in experimental animals. Glycidamide (GA), formed by metabolic epoxidation of AA, is believed to be responsible for the carcinogenicity of AA. Occupational exposure to AA has been assessed earlier by measurement of its adducts with N-terminal valine in hemoglobin. A background of AA adducts [N-(2-carbamoylethyl)valine (AAVal), about 30 pmol/g globin] was found in individuals without known exposure to the compound. The method previously available for adducts of GA only allowed analysis of samples from highly exposed individuals and showed similar levels of AAVal and adducts of GA [N-(2-hydroxy-2-carbamoylethyl)valine (GAVal)]. We have developed a sensitive method for simultaneous quantification of adducts of GA and AA, which is suitable down to low exposure levels. The method is based on the so-called modified Edman method, where globin is reacted with pentafluorophenyl isothiocyanate under neutral conditions. The valine adducts are then extracted in the form of pentafluorophenylthiohydantoin (PFPTH) derivatives. The analytical procedure included reaction of the PFPTH derivatives with acetic anhydride in order to protect the hydroxyl group of GAVal. The PFPTH derivatives of AAVal and GAVal were analyzed by gas chromatography/tandem mass spectrometry. ((2)H(3))AAVal-PFPTH was used as the internal standard. The method was applied to samples from 11 workers at an AA production plant, 1 nonexposed nonsmoker, and a few participants of a smoking cessation program. AAVal levels were in the range 27-1854 pmol/g globin. Recorded levels of GAVal were 3-12% of those of AAVal, suggesting that previous measurements of GAVal overestimate GAVal at low levels of exposure to AA.

  14. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSDchromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.).

  15. Gas Chromatography-Mass Spectrometry Analysis of Ulva fasciata (Green Seaweed) Extract and Evaluation of Its Cytoprotective and Antigenotoxic Effects.

    Science.gov (United States)

    Rodeiro, Idania; Olguín, Sitlali; Santes, Rebeca; Herrera, José A; Pérez, Carlos L; Mangas, Raisa; Hernández, Yasnay; Fernández, Gisselle; Hernández, Ivones; Hernández-Ojeda, Sandra; Camacho-Carranza, Rafael; Valencia-Olvera, Ana; Espinosa-Aguirre, Jesús Javier

    2015-01-01

    The chemical composition and biological properties of Ulva fasciata aqueous-ethanolic extract were examined. Five components were identified in one fraction prepared from the extract by gas chromatography-mass spectrometry, and palmitic acid and its ethyl ester accounted for 76% of the total identified components. Furthermore, we assessed the extract's antioxidant properties by using the DPPH, ABTS, and lipid peroxidation assays and found that the extract had a moderate scavenging effect. In an experiment involving preexposition and coexposition of the extract (1-500 µg/mL) and benzo[a]pyrene (BP), the extract was found to be nontoxic to C9 cells in culture and to inhibit the cytotoxicity induced by BP. As BP is biotransformed by CYP1A and CYP2B subfamilies, we explored the possible interaction of the extract with these enzymes. The extract (25-50 µg/mL) inhibited CYP1A1 activity in rat liver microsomes. Analysis of the inhibition kinetics revealed a mixed-type inhibitory effect on CYP1A1 supersome. The effects of the extract on BP-induced DNA damage and hepatic CYP activity in mice were also investigated. Micronuclei induction by BP and liver CYP1A1/2 activities significantly decreased in animals treated with the extract. The results suggest that Ulva fasciata aqueous-ethanolic extract inhibits BP bioactivation and it may be a potential chemopreventive agent.

  16. Gas Chromatography-Mass Spectrometry Analysis of Ulva fasciata (Green Seaweed Extract and Evaluation of Its Cytoprotective and Antigenotoxic Effects

    Directory of Open Access Journals (Sweden)

    Idania Rodeiro

    2015-01-01

    Full Text Available The chemical composition and biological properties of Ulva fasciata aqueous-ethanolic extract were examined. Five components were identified in one fraction prepared from the extract by gas chromatography-mass spectrometry, and palmitic acid and its ethyl ester accounted for 76% of the total identified components. Furthermore, we assessed the extract’s antioxidant properties by using the DPPH, ABTS, and lipid peroxidation assays and found that the extract had a moderate scavenging effect. In an experiment involving preexposition and coexposition of the extract (1–500 µg/mL and benzo[a]pyrene (BP, the extract was found to be nontoxic to C9 cells in culture and to inhibit the cytotoxicity induced by BP. As BP is biotransformed by CYP1A and CYP2B subfamilies, we explored the possible interaction of the extract with these enzymes. The extract (25–50 µg/mL inhibited CYP1A1 activity in rat liver microsomes. Analysis of the inhibition kinetics revealed a mixed-type inhibitory effect on CYP1A1 supersome. The effects of the extract on BP-induced DNA damage and hepatic CYP activity in mice were also investigated. Micronuclei induction by BP and liver CYP1A1/2 activities significantly decreased in animals treated with the extract. The results suggest that Ulva fasciata aqueous-ethanolic extract inhibits BP bioactivation and it may be a potential chemopreventive agent.

  17. Gas Chromatography-Mass Spectrometry Analysis of Ulva fasciata (Green Seaweed) Extract and Evaluation of Its Cytoprotective and Antigenotoxic Effects

    Science.gov (United States)

    Rodeiro, Idania; Olguín, Sitlali; Santes, Rebeca; Herrera, José A.; Pérez, Carlos L.; Mangas, Raisa; Hernández, Yasnay; Fernández, Gisselle; Hernández, Ivones; Hernández-Ojeda, Sandra; Camacho-Carranza, Rafael; Valencia-Olvera, Ana; Espinosa-Aguirre, Jesús Javier

    2015-01-01

    The chemical composition and biological properties of Ulva fasciata aqueous-ethanolic extract were examined. Five components were identified in one fraction prepared from the extract by gas chromatography-mass spectrometry, and palmitic acid and its ethyl ester accounted for 76% of the total identified components. Furthermore, we assessed the extract's antioxidant properties by using the DPPH, ABTS, and lipid peroxidation assays and found that the extract had a moderate scavenging effect. In an experiment involving preexposition and coexposition of the extract (1–500 µg/mL) and benzo[a]pyrene (BP), the extract was found to be nontoxic to C9 cells in culture and to inhibit the cytotoxicity induced by BP. As BP is biotransformed by CYP1A and CYP2B subfamilies, we explored the possible interaction of the extract with these enzymes. The extract (25–50 µg/mL) inhibited CYP1A1 activity in rat liver microsomes. Analysis of the inhibition kinetics revealed a mixed-type inhibitory effect on CYP1A1 supersome. The effects of the extract on BP-induced DNA damage and hepatic CYP activity in mice were also investigated. Micronuclei induction by BP and liver CYP1A1/2 activities significantly decreased in animals treated with the extract. The results suggest that Ulva fasciata aqueous-ethanolic extract inhibits BP bioactivation and it may be a potential chemopreventive agent. PMID:26612994

  18. Gas chromatography-mass spectrometry analysis of different organic crude extracts from the local medicinal plant of Thymus vulgaris L

    Institute of Scientific and Technical Information of China (English)

    Laila Salim Al Hashmi; Mohammad Amzad Hossain; Afaf Mohammed Weli; Qasim Al-Riyami; Jamal Nasser Al-Sabahi

    2013-01-01

    Objective: To isolate and analyze the chemical composition in different crude extracts of from the leaves of locally grown of Thymus vulgaris L (T. vulgaris) by gas chromatography-mass spectrometry (GC-MS). Methods: The shade dried leaves powder was extracted with methanol by using Soxhlet extractor. Methanol crude extracts of T. vulgaris and the derived fractions of hexane, chloroform, ethyl acetate and butanol were obtained. Results: Qualitative analyses of various organic crude extracts of T. vulgaris by using GC-MS showed that there were different types of high and low molecular weight compounds. Most of the isolated and identified compounds by GC-MS in the crude extracts are basically biologically important. Further, the T. vulgaris leaf possessed certain characteristics that can be ascribed to cultivation on a domestic plantation. The crude extracts were prepared from the powder leaves of T. vulgaris for respective compounds can be chosen on the basis of above GC-MS analysis. Conclusions: All the major compounds were identified and characterized by spectroscopic method in different organic crude extracts of T. vulgaris are biologically active molecules. Thus the identification of a good number of compounds in various crude extracts of T. vulgaris might have some ecological role.

  19. Gas chromatography-mass spectrometry analysis of different organic crude extracts from the local medicinal plant of Thymus vulgaris L

    Institute of Scientific and Technical Information of China (English)

    Laila; Salim; Al; Hashmi; Mohammad; Amzad; Hossain; Afaf; Mohammed; Weli; Qasim; Al-Riyami; Jamal; Nasser; Al-Sabahi

    2013-01-01

    Objective:To isolate and analyze the chemical composition in different crude extracts of from the leaves of locally grown of Thymus vulgaris L(T.vulgaris)by gas chromatography-mass spectrometry(GC-MS).Methods:The shade dried leaves powder was extracted with methanol by using Soxhlet extractor.Methanol crude extracts of T.vulgaris and the derived fractions of hexane,chloroform,ethyl acetate and butanol were obtained.Results:Qualitative analyses of various organic crude extracts of T.vulgaris by using GC-MS showed that there were different types of high and low molecular weight compounds.Most of the isolated and identified compounds by GC-MS in the crude extracts are basically biologically important.Further,the T.vulgaris leaf possessed certain characteristics that can be ascribed to cultivation on a domestic plantation.The crude extracts were prepared from the powder leaves of T.vulgaris for respective compounds can be chosen on the basis of above GC-MS analysis.Conclusions:All the major compounds were identified and characterized by spectroscopic method in different organic crude extracts of T.vulgaris are biologically active molecules.Thus the identification of a good number of compounds in various crude extracts of T.vulgaris might have some ecological role.

  20. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Jin; Shin, Yeon Jae; Oh, Se Yeon; Kim, Nam Sun; Kim, Kun; Lee, Dong Sun [Seoul Women' s University, Seoul (Korea, Republic of)

    2006-02-15

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (K{sub lh}) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

  1. Thermal degradation behavior of waste video cards using thermogravimetric analysis and pyrolysis gas chromatography/mass spectrometry techniques.

    Science.gov (United States)

    Duan, Huabo; Li, Jinhui

    2010-05-01

    The thermal degradation characteristics of a printed circuit board assembly (PCBA), specifically video cards from waste computers, was studied using pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS) and thermogravimetric analysis (TGA). The video-card waste was dismantled into substrate, integrated circuits (ICs), and plastic slots for comparable investigation. The results by TGA revealed that the initial temperature at which degradation began was 300 degrees C for substrate, but it was 330 degrees C for ICs and plastic slots. For a given type of scrap, the initial temperature leading to degradation is the same under air and N2 atmosphere. However, the degradation rate was lower using air than N2 during the weight-loss stage. Further Py-GC/MS application revealed that pyrolysis products derived from substrate consisted mainly of acetone, bromotoluene, and phenol that came from the brominated epoxy resins present in substrate. Unlike substrate, the relative amounts of some products (e.g., phenol) were higher in the ICs, and cyclotetrasiloxane was released; these were released from the phenolic resins and Si mixture present in that type of waste. Benzoic acid, rather than acetone or phenol, was the main product released from plastic slots. It was proved that this scrap was a mixture of various polyesters, cracking of which predicatively generated aromatic products. The results will be useful in developing pyrolysis or starved-air incineration systems for thermosetting plastic and PCBA waste and helpful to control pollution during the treatment of this waste.

  2. [Analysis of pesticide multiresidues in rice by gas chromatography-mass spectrometry coupled with solid phase extraction].

    Science.gov (United States)

    Liu, Pengyan; Liu, Qingxue; Ma, Yusong; Liu, Jinwei; Jia, Xuan

    2006-05-01

    A new analytical method was developed to simultaneously determine multiple pesticide residues in rice including organophosphorus, organochlorine, carbamate and pyrethroid. First, the solvents for pesticide extraction were selected for optimization. Eight solvents were screened to find that the extraction efficiency with dichloromethane was the best. Second, clean-up was performed by solid phase extraction using a Florisil cartridge. Various mixtures of hexane and acetone were tested to show that the mixture of hexane-acetone (4:1, v/v) had the best performance. The clean-up helped the sample purification significantly. The prepared sample was analyzed using gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. The pesticides were identified with retention time and selected ions and their relative abundances, and they were quantified based on extract of spiking standards in a blank sample. The limits of detection (LODs) were evaluated on the values of the lower concentration fortified sample under the signal-to-noise ratio of 3:1. The recoveries and relative standard deviations (RSDs) were checked by adding pesticide standard solution at two levels to untreated samples, and the triplicate analysis of the samples were carried out for each spiked level. The LODs were at microg/kg level. The average recoveries of most pesticides were from 75% to 120 %. The RSDs were less than 10.4% (n = 3). These results indicated that this method is simple, rapid, sensitive for the simultaneous determination requirements of multiple pesticide residues in rice.

  3. Analysis of aromatic hydrocarbons in petroleum fractions using gas chromatography, mass spectrometry and mass fragmentrography

    Energy Technology Data Exchange (ETDEWEB)

    Kubelka, V.

    1980-01-01

    Mass spectrometry in combination with gas chrom. used to analyze hydrocarbon mixtures results in qualit. and semi-quant. data regarding composition of the analyzed mixture. Use of mass fragmentrography during chromatographic separation will allow simultaneous recording of changes in intensity of characteristic ions and thus determine the retention index, for this substance. Combining mass spectre and retention index, it is possible to identify the given subst. or limit the number of possible combinations.

  4. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    Science.gov (United States)

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected.

  5. Analysis of glyphosate residues in cereals using liquid chromatography-mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Granby, Kit; Johannesen, S.; Gabrielsen, Martin Vahl

    2003-01-01

    A fast and specific method for the determination of glyphosate in cereals is described. The method is based on extraction with water by ultrasonication. The samples are cleaned up and separated by high-performance liquid chromatography on a polystyrene-based reverse-phase column (clean......-up) in series with an ion chromatography column (separation) using NaHCO3 as eluent. A micro-membrane suppressor was inserted after the separator column to remove the Na + ions before detection by electrospray ionization mass spectrometry in the negative-ion mode. In MS/MS, mode the following transitions were...

  6. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  7. Liquid chromatography/mass spectrometry analysis of branched fructans produced in vitro with C-13-labeled substrates

    DEFF Research Database (Denmark)

    Verspreet, Joran; Hansen, Anders Holmgaard; Dornez, Emmie

    2014-01-01

    . Liquid chromatography/mass spectrometry (LC/MS) was used for the structural identification of branched fructans. The MS2 fragmentation of these compounds is described for the first time. Analytes were charged by electrospray ionization in negative mode and a quadrupole mass analyzer was used for MS2....... CONCLUSIONSThe MS2 fragmentation patterns described in the current paper now allow rapid screening of large sample sets for the presence of branched, graminan-type fructans. Furthermore, the data enables the characterization of fructan-metabolizing enzymes by identification of the fructan structures produced...

  8. Application of acetate derivatives for gas chromatography-mass spectrometry: novel approaches on carbohydrates, lipids and amino acids analysis.

    Science.gov (United States)

    Sassaki, Guilherme L; Souza, Lauro M; Serrato, Rodrigo V; Cipriani, Thales R; Gorin, Philip A J; Iacomini, Marcello

    2008-10-24

    The structure of glycoconjugates has been determined by several chromatographic methods, however gas chromatography-mass spectrometry (GC-MS) has been widely used to identify and quantify the volatile trimethylsilyl and fluoroacyl derivatives. Adapting the reduction/acetylation strategies, we had performed the derivatization of all monosaccharide class, as well as amino acids and OH-fatty acids as from different glycoconjugates. Uronic acids gave characteristic ions at m/z 143, 156 and 173, and 19 amino acids derivatives, gave molecular ions [M]+ and daughter ions of [M-59]+ and [M-43]+ on electron impact (EI)-MS, which provide their rapid identification.

  9. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-01-01

    g/mL). All other extracts were nontoxic. A total of 145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. Conclusions: The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. SUMMARY Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. PMID:27279705

  10. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  11. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  12. Gas chromatography mass spectrometry computer analysis of volatile halogenated hydrocarbons in man and his environment--A multimedia environmental study.

    Science.gov (United States)

    Barkley, J; Bunch, J; Bursey, J T; Castillo, N; Cooper, S D; Davis, J M; Erickson, M D; Harris, B S; Kirkpatrick, M; Michael, L C; Parks, S P; Pellizzari, E D; Ray, M; Smith, D; Tomer, K B; Wagner, R; Zweidinger, R A

    1980-04-01

    As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatography mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.

  13. High-performance liquid chromatography-mass spectrometry analysis of plant metabolites in brassicaceae.

    Science.gov (United States)

    De Vos, Ric C H; Schipper, Bert; Hall, Robert D

    2012-01-01

    The Brassicaceae family comprises a variety of plant species that are of high economic importance as -vegetables or industrial crops. This includes crops such as Brassica rapa (turnip, Bok Choi), B. oleracea (cabbages, broccoli, cauliflower, etc.), and B. napus (oil seed rape), and also includes the famous genetic model of plant research, Arabidopsis thaliana (thale cress). Brassicaceae plants contain a large variety of interesting secondary metabolites, including glucosinolates, hydroxycinnamic acids, and flavonoids. These metabolites are also of particular importance due to their proposed positive effects on human health. Next to these well-known groups of phytochemicals, many more metabolites are of course also present in crude extracts prepared from Brassica and Arabidopsis plant material.High-pressure liquid chromatography coupled to mass spectrometry (HPLC-MS), especially if combined with a high mass resolution instrument such as a QTOF MS, is a powerful approach to separate, detect, and annotate metabolites present in crude aqueous-alcohol plant extracts. Using an essentially unbiased procedure that takes into account all metabolite mass signals from the raw data files, detailed information on the relative abundance of hundreds of both known and, as yet, unknown semipolar metabolites can be obtained. These comprehensive metabolomics data can then be used to, for instance, identify genetic markers regulating metabolic composition, determine effects of (a)biotic stress or specific growth conditions, or establish metabolite changes occurring upon food processing or storage.This chapter describes in detail a procedure for preparing crude extracts and performing comprehensive HPLC-QTOF MS-based profiling of semi-polar metabolites in Brassicaceae plant material. Compounds present in the extract can be (partially or completely) annotated based on their accurate mass, their MS/MS fragments and on other specific chemical characteristics such as retention time and UV

  14. Extraction, gas chromatography-mass spectrometry analysis and screening of fruits of Terminalia chebula Retz. for its antimicrobial potential

    Directory of Open Access Journals (Sweden)

    Geeta Singh

    2013-01-01

    Full Text Available Background: Terminalia chebula is called the "king of medicines" in Tibet and is always listed first in the Ayurvedic meteria medica because of its extraordinary powers of healing. Objective: Identification, isolation and screening of pyrogallol which are responsible for antimicrobial property of fruits of Terminalia chebula. Materials and Methods: Ethyl acetate fraction of fruits of Terminalia chebula was subjected to Gas chromatography-mass spectrometry (GC-MS for the components present in the extract. Results: Sixty four constituents were identified out of which kaempferol-3-O-rutinoside flavonoid and Vitamin E has been detected for the first time in fruits of this plant. Pyrogallol (46.26% which was the major component of the extract in GC-MS analysis was isolated and screened for antimicrobial activity against selected test pathogens by Disc Diffusion Assay. Crude ethyl acetate fraction of the fruits was showing the same activity potential as was observed for pure pyrogallol which was the major component as per GC-MS analysis. The most sensitive species among the bacteria was Enterobacter aerogenes with highest inhibition zone (IZ = 31 mm; AI = 1.409 ± 0.046 even at minimum inhibitory concentration (0.039 mg/ml. Conclusion: Hence activity shown by crude ethyl acetate fraction might be due to pyrogallol present in the extract. On the basis of results it can be advocate that achieved crude ethyl acetate fraction can be explored for preparing antimicrobial drugs in future for the infectious caused by the pathogens tested in the study.

  15. Multi-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS

    Directory of Open Access Journals (Sweden)

    Azadeh Emami

    2014-12-01

    Full Text Available Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket. Methods: We developed a "Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS method based on spiking blank samples and used the data for drawing calibration curves instead of standard solutions. Sample preparations were developed for determination of 12 pesticide residues in pistachio by gas chromatography-mass spectrometry (GC/MS. Results: Recovery of pesticides at 5 concentration levels (n=3 was in the range of 81.40% - 93.08 %. The method proved to be repeatable in the majority of samples with relative standard deviation (RSD of lower than 20%. The limits of detection and quantification for all pesticides were 2 ppb and 10 ppb, respectively. Conclusion: The calibration curves of pesticides were linear in the range of 10-500 (ng/g and correlation coefficient of entire pesticides was higher than 0.994. The recovery of pesticides at 5 concentration levels (n=3 was in range of 81.41- 91.80 %. The method was proved to be repeatable with the majority of RSDs being lower than 20%. The limits of detection and quantification for all pesticides were 2 and 10 ppb, respectively. The recoveries and repeatabilities were in accordance with the criteria set by SANCO Guideline (Commission of the European Communities, 2006.

  16. Liquid Chromatography-Mass Spectrometry Analysis of DNA Polymerase Reaction Products

    Science.gov (United States)

    Chowdhury, Goutam; Guengerich, F. Peter

    2013-01-01

    This unit describes experimental and analytical procedures for characterizing the efficiency and fidelity of translesion DNA synthesis across various DNA damages by DNA polymerases in vitro. This procedure utilizes primer extension assays followed by LC-MS and LC-MS/MS analysis of the extension products. Detailed explanations for the analysis of the LC-MS/MS data for deciphering the nucleotide sequences of the DNA fragments are also presented. This approach provides a significant improvement over conventional methods, as it allows detection of misincorporation, as well as frameshift products. PMID:22147421

  17. Analysis of acrylamide in green tea by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Mizukami, Yuzo; Kohata, Katsunori; Yamaguchi, Yuichi; Hayashi, Nobuyuki; Sawai, Yusuke; Chuda, Yoshihiro; Ono, Hiroshi; Yada, Hiroshi; Yoshida, Mitsuru

    2006-09-20

    Optimization of the solid-phase extraction cleanup procedure enabled the GC-MS analysis of acrylamide in tea samples without the interference of bromination by tea catechins. Although polyvinylpolypyrrolidone (PVPP) is available for removing tea catechins from tea extract, the peaks derived from PVPP had the same retention time as brominated acrylamide in mass chromatograms obtained by GC-MS. A considerable amount of acrylamide was formed at roasting temperatures of > or =120 degrees C; the highest acrylamide level was observed when tea samples were roasted at 180 degrees C for 10 min. Higher temperatures and longer processing times caused a decrease in the acrylamide content. Furthermore, an analysis of 82 tea samples showed that rather than the reducing sugar content, the asparagine content in tea leaves was a significant factor related to acrylamide formation in roasted products. The acrylamide level in roasted tea products was controlled by asparagine in the presence of reducing sugars.

  18. Recent advances and trends in the liquid-chromatography-mass spectrometry analysis of flavonoids.

    Science.gov (United States)

    de Villiers, André; Venter, Pieter; Pasch, Harald

    2016-01-22

    Flavonoids have elicited significant attention as a result of their importance in plants, their influence on the properties of natural-product derived commodities and especially as a consequence of their purported health benefits. Research in all of these fields relies heavily on accurate analytical data, and in this LC-MS has come to play an influential role by allowing relatively fast tentative identification and accurate quantification of low levels of flavonoids in a variety of matrices. The field has undergone rapid expansion in the last decade due to important developments in both HPLC and MS instrumentation, which nowadays allow much faster and more accurate analysis of flavonoids. This contribution aims to provide an overview of these developments and their application in flavonoid analysis since 2009. The discussion is focussed first on methodologies which provide improved LC separation of flavonoids in terms of speed and/or resolution, including ultra high pressure LC (UHPLC), monolithic and superficially porous phases, high temperature LC (HTLC) and comprehensive two-dimensional LC (LC×LC). The fundamental background relevant to each of these will be briefly outlined, as well as the implications and promise of their hyphenation to MS. Secondly, the possibilities and limitations of a range of the latest MS instruments available in combination with advanced LC analysis will be discussed, including ion trap, triple quadrupole, time-of-flight, Orbitrap, ion mobility and various hybrid instruments. Examples from the latest literature will be used to illustrate the performance gains achievable in flavonoid analysis by the hyphenation of advanced LC separation and high-end MS instrumentation.

  19. Analysis of Indole Alkaloids from Rhazya stricta Hairy Roots by Ultra-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Akhgari, Amir; Laakso, Into; Seppänen-Laakso, Tuulikki; Yrjönen, Teijo; Vuorela, Heikki; Oksman-Caldentey, Kirsi-Marja; Rischer, Heiko

    2015-12-17

    Rhazya stricta Decne. (Apocynaceae) contains a large number of terpenoid indole alkaloids (TIAs). This study focused on the composition of alkaloids obtained from transformed hairy root cultures of R. stricta employing ultra-performance liquid chromatography-mass spectrometry (UPLC-MS). In the UPLC-MS analyses, a total of 20 TIAs were identified from crude extracts. Eburenine and vincanine were the main alkaloids followed by polar glucoalkaloids, strictosidine lactam and strictosidine. Secodine-type alkaloids, tetrahydrosecodinol, tetrahydro- and dihydrosecodine were detected too. The occurrence of tetrahydrosecodinol was confirmed for the first time for R. stricta. Furthermore, two isomers of yohimbine, serpentine and vallesiachotamine were identified. The study shows that a characteristic pattern of biosynthetically related TIAs can be monitored in Rhazya hairy root crude extract by this chromatographic method.

  20. Gas Chromatography-mass Spectrometry (GC-MS analysis of alkaloids isolated from Epipremnum aureum (Linden and Andre Bunting

    Directory of Open Access Journals (Sweden)

    Anju Meshram

    2015-02-01

    Full Text Available Recent advances in the use of GC coupled to MS have allowed a chemically guided isolation of uncommon and bioactive alkaloids. The present study was aimed to focus on the extraction and screening of alkaloids from Epipremnum aureum (Linden and Andre Bunting. It has been observed that the plant is very rich in alkaloids and the modified method employed for the extraction of alkaloid is efficient and selective, where the interference of other secondary metabolites is negligible. The identification of each compound was made through gas chromatography-mass spectrometry (GC-MS. A total of twenty six structurally different alkaloids were identified for the first time from this plant. E. aureum is highly rich in alkaloids and twenty six different alkaloids were characterized. The present study may help in the field of natural products’ chemistry and pharmaceuticals as well as drug discovery science and technology.

  1. Gas chromatography-mass spectrometry analysis of fatty acid profiles of Antarctic and non-Antarctic yeasts.

    Science.gov (United States)

    Bhuiyan, Mohammad; Tucker, David; Watson, Kenneth

    2014-08-01

    The fatty acid profiles of Antarctic (n = 7) and non-Antarctic yeasts (n = 7) grown at different temperatures were analysed by gas chromatography-mass spectrometry. The Antarctic yeasts were enriched in oleic 18:1 (20-60 %), linoleic 18:2 (20-50 %) and linolenic 18:3 (5-40 %) acids with lesser amounts of palmitic 16:0 (Antarctic yeasts (n = 4) were enriched in 18:1 (20-55 %, with R. mucilaginosa at 75-80 %) and 18:2 (10-40 %) with lesser amounts of 16:0 (Antarctic yeasts (enriched in 18:1 and 18:2) and the third to the Antarctic yeasts (enriched in 18:2 and 18:3).

  2. Analysis of Indole Alkaloids from Rhazya stricta Hairy Roots by Ultra-Performance Liquid Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Amir Akhgari

    2015-12-01

    Full Text Available Rhazya stricta Decne. (Apocynaceae contains a large number of terpenoid indole alkaloids (TIAs. This study focused on the composition of alkaloids obtained from transformed hairy root cultures of R. stricta employing ultra-performance liquid chromatography-mass spectrometry (UPLC-MS. In the UPLC-MS analyses, a total of 20 TIAs were identified from crude extracts. Eburenine and vincanine were the main alkaloids followed by polar glucoalkaloids, strictosidine lactam and strictosidine. Secodine-type alkaloids, tetrahydrosecodinol, tetrahydro- and dihydrosecodine were detected too. The occurrence of tetrahydrosecodinol was confirmed for the first time for R. stricta. Furthermore, two isomers of yohimbine, serpentine and vallesiachotamine were identified. The study shows that a characteristic pattern of biosynthetically related TIAs can be monitored in Rhazya hairy root crude extract by this chromatographic method.

  3. Response to weaning and dietary L-glutamine supplementation:metabolomic analysis in piglets by gas chromatography/mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Ying-ping XIAO; Tian-xing WU; Qi-hua HONG; Jiang-ming SUN; An-guo CHEN; Cai-mei YANG; Xiao-yan LI

    2012-01-01

    A novel metabolomic method based on gas chromatography/mass spectrometry (GC-MS) was applied to determine the metabolites in the serum of piglets in response to weaning and dietary L-glutamine (Gln) supplementation.Thirty six 21-d-old piglets were randomly assigned into three groups.One group continued to suckle from the sows (suckling group),whereas the other two groups were weaned and their diets were supplemented with 1% (w/w) Gln or isonitrogenous L-alanine,respectively,representing Gin group or control group.Serum samples were collected to characterize metabolites after a 7-d treatment.Results showed that twenty metabolites were down-regulated signifi cantly (P<0.05) in control piglets compared with suckling ones.These data demonstrated that early weaning causes a wide range of metabolic changes across arginine and proline metabolism,aminosugar and nucleotide metabolism,galactose metabolism,glycerophospholipid metabolism,biosynthesis of unsaturated fatty acid,and fatty acid metabo lism.Dietary Gin supplementation increased the levels of creatinine,o-xylose,2-hydroxybutyric acid,palmitelaidic acid,and α-L- galactofuranose (P<0.05) in early weaned piglets,and were involved in the arginine and proline metabolism,carbohydrate metabolism,and fatty acid metabolism.A leave one out cross validation of random forest analysis indi cated that creatinine was the most important metabolite among the three groups.Notably,the concentration of craatinine in control piglets was decreased (P=0.00001) compared to the suckling piglets,and increased (P=0.0003) in Gin-supplemented piglets.A correlation network for weaned and suckling piglets revealed that eady weaning changed the metabolic pathways,leading to the abnormality of carbohydrate metabolism,amino acid metabolism,and lipid metabolism,which could be partially improved by dietary Gin supplementation.These findings provide fresh insight into the complex metabolic changes in response to early weaning and dietary Gin

  4. Titan's organic aerosols: Molecular composition and structure of laboratory analogues inferred from pyrolysis gas chromatography mass spectrometry analysis

    Science.gov (United States)

    Morisson, Marietta; Szopa, Cyril; Carrasco, Nathalie; Buch, Arnaud; Gautier, Thomas

    2016-10-01

    Analogues of Titan's aerosols are of primary interest in the understanding of Titan's atmospheric chemistry and climate, and in the development of in situ instrumentation for future space missions. Numerous studies have been carried out to characterize laboratory analogues of Titan aerosols (tholins), but their molecular composition and structure are still poorly known. If pyrolysis gas chromatography mass spectrometry (pyr-GCMS) has been used for years to give clues about their chemical composition, highly disparate results were obtained with this technique. They can be attributed to the variety of analytical conditions used for pyr-GCMS analyses, and/or to differences in the nature of the analogues analyzed, that were produced with different laboratory set-ups under various operating conditions. In order to have a better description of Titan's tholin's molecular composition by pyr-GCMS, we carried out a systematic study with two major objectives: (i) exploring the pyr-GCMS analytical parameters to find the optimal ones for the detection of a wide range of chemical products allowing a characterization of the tholins composition as comprehensive as possible, and (ii) highlighting the role of the CH4 ratio in the gaseous reactive medium on the tholin's molecular structure. We used a radio-frequency plasma discharge to synthetize tholins with different concentrations of CH4 diluted in N2. The samples were pyrolyzed at temperatures covering the 200-700°C range. The extracted gases were then analyzed by GCMS for their molecular identification. The optimal pyrolysis temperature for characterizing the molecular composition of our tholins by GCMS analysis is found to be 600°C. This temperature choice results from the best compromise between the number of compounds released, the quality of the signal and the appearance of pyrolysis artifacts. About a hundred molecules are identified as pyrolysates. A common major chromatographic pattern appears clearly for all the

  5. Pressurized liquid extraction-gas chromatography-mass spectrometry analysis of fragrance allergens, musks, phthalates and preservatives in baby wipes.

    Science.gov (United States)

    Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria

    2015-03-01

    Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between

  6. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  7. Analysis of pharmaceutical and other organic wastewater compounds in filtered and unfiltered water samples by gas chromatography/mass spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Phillips, Patrick J.; Smith, Steven G.

    2014-01-01

    types were determined by use of the capillary-column gas chromatography/mass spectrometry. The performance of each method was assessed by using data on recoveries of compounds in fortified surface-water, wastewater, and reagent-water samples. These experiments (referred to as spike experiments) consist of fortifying (or spiking) samples with known amounts of target analytes. Surface-water-spike experiments were performed by using samples obtained from a stream in Colorado (unfiltered method) and a stream in New York (filtered method). Wastewater spike experiments for both the filtered and unfiltered methods were performed by using a treated wastewater obtained from a single wastewater treatment plant in New York. Surface water and wastewater spike experiments were fortified at both low and high concentrations and termed low- and high-level spikes, respectively. Reagent water spikes were assessed in three ways: (1) set spikes, (2) a low-concentration fortification experiment, and (3) a high-concentration fortification experiment. Set spike samples have been determined since 2009, and consist of analysis of fortified reagent water for target compounds included for each group of 10 to18 environmental samples analyzed at the NWQL. The low-concentration and high-concentration reagent spike experiments, by contrast, represent a one-time assessment of method performance. For each spike experiment, mean recoveries ranging from 60 to 130 percent indicate low bias, and relative standard deviations (RSDs) less than ( Of the compounds included in the filtered method, 21 had mean recoveries ranging from 63 to 129 percent for the low-level and high-level surface-water spikes, and had low ()132 percent]. For wastewater spikes, 24 of the compounds included in the filtered method had recoveries ranging from 61 to 130 percent for the low-level and high-level spikes. RSDs were 130 percent) or variable recoveries (RSDs >30 percent) for low-level wastewater spikes, or low recoveries ( Of

  8. Rapid method for the determination of 16 organochlorine pesticides in sesame seeds by microwave-assisted extraction and analysis of extracts by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Papadakis, Emmanouil N; Vryzas, Zisis; Papadopoulou-Mourkidou, Euphemia

    2006-09-15

    A method for the multiresidue analysis of 16 organochlorine insecticides in sesame seeds has been developed. The method is based on the microwave-assisted extraction (MAE) of the sesame seeds by the use of a water-acetonitrile mixture followed by Florisil clean-up of the extracts and subsequent analysis by gas chromatography-mass spectrometry (GC/MS) in the selected ion monitoring (SIM) mode. MAE operational parameters (extraction solvent, temperature and time, extractant volume) were optimized with respect to extraction efficiency of the target compounds from sesame seeds with 46% oil content. Recoveries >80% with relative standard deviations (RSD) seed samples imported to Greece.

  9. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    OpenAIRE

    Michaela Vieriková; Miriam Vlčáková

    2010-01-01

     Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS) after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS). Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detect...

  10. Derivatisation/solid-phase microextraction followed by gas chromatography-mass spectrometry for the analysis of phenoxy acid herbicides in aqueous samples

    DEFF Research Database (Denmark)

    Nilsson, Torben; Baglio, Daniela; Galdo-Miguez, Isabel

    1998-01-01

    Different combinations of derivatisation and solid-phase microextraction followed by gas chromatography-mass spectrometry were optimised and evaluated for the analysis of phenoxy acid herbicides in water. The most successful derivatisation approach was aqueous-phase derivatisation with benzyl...... bromide. The benzyl esters were extracted most efficiently by the solid-phase microextraction fibre coated with polydimethylsiloxane-divinylbenzene. No carry-over problems were encountered with this fibre upon desorption at 250 degrees C. Detection limits in the ng/l range were obtained, while...

  11. Ultrasonic Nebulization Extraction Coupled with Gas Chromatography-Mass Spectrometry for Analysis of Volatile Components in Traditional Chinese Patent Medicine

    Institute of Scientific and Technical Information of China (English)

    LIANG Yue; WANG Lu; WANG Zi-ming; YU Cui; ZHANG Han-qi; SHI Yu-hua

    2011-01-01

    The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization extraction including the sample particle size, solvent volume, extraction time and ultrasonic power were studied and selected. As a result, 2.4 g of sample with particle size of 80 mesh was extracted with 15 mL of n-hexane for 20 min at an ultrasonic power of 35 W. The volatile components were analyzed by gas chromatography-mass spectrometry (GC-MS) under the optimal conditions and 57 compounds were identified. The precision, repeatability and stability of the proposed method were also studied. Compared with ultrasonic-assisted extraction(UAE) and hydrodistillation(HD) extraction, the proposed method is more efficient, faster and easier to be operated at room temperature with smaller sample and energy consumption. It is suggested that the ultrasonic nebulization extraction can be used as a novel alternative method for the extraction of volatile components from traditional Chinese patent medicine.

  12. A metabolic profiling analysis of the nephrotoxicity of acyclovir in rats using ultra performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Xing, Wenmin; Gu, Lili; Zhang, Xinyue; Xu, Jiadong; Lu, Hong

    2016-09-01

    Acyclovir (ACV) exposure is a common cause of acute kidney injury (AKI). The toxicity mechanism of ACV has always been a matter of debate. The present study investigated into the time-effect relationship and dose-effect relationship of ACV-induced nephrotoxicity in rats using metabonomics. Twenty-four rats were randomly divided into four groups: a 0.9% NaCl solution group, and 100, 300, and 600mg/kg ACV-treated groups; the ACV or vehicle solution was administered with a single intravenous injection. Urine was collected at different time periods (12h before administration, and 0-6h, 7-12h, and 13-24h after administration). Routine urinalysis was conducted by a urine automatic analyzer. Renal markers, including urine urea nitrogen, urine creatinine, and urinary N-acetyl-β-d-glucosaminidase (NAG) activity, were determined using established protocols. Urinary metabolites were evaluated using ultra performance liquid chromatography/mass spectrometry (UPLC/MS). In the ACV-treated rats, increased levels of protein (PRO), occult blood (BLD), white blood cell (WBC), and NAG activity in urine were observed, while the urine creatinine and urea nitrogen levels showed a decrease compared with the control. Moreover, urine metabolites significantly changed after the treatment with ACV, and all the effects induced by ACV were dose-time dependent. Finally, 4 metabolites (guanine, 4-guanidinobutyric acid, creatinine, and urea) were identified, which can be used for further research on the mechanism of ACV-induced nephrotoxicity.

  13. Differentiation of the volatile profile of microbiologically contaminated canned tomatoes by dynamic headspace extraction followed by gas chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Bianchi, F; Careri, M; Mangia, A; Mattarozzi, M; Musci, M; Concina, I; Falasconi, M; Gobbi, E; Pardo, M; Sberveglieri, G

    2009-01-15

    The aromatic profile of microbiologically contaminated canned tomatoes was analyzed by the dynamic headspace extraction technique coupled with gas chromatography-mass spectrometry. Canned tomatoes contaminated with Escherichia coli, Saccharomyces cerevisiae and Aspergillus carbonarius were analyzed after 2 and 7 days. About 100 volatiles were detected, among which alcohols, aldehydes and ketones were the most abundant compounds. Gas chromatographic peak areas were used for statistical purposes. First, principal component analysis was carried out in order to visualize data trends and clusters. Then, linear discriminant analysis was performed in order to detect the set of volatile compounds ables to differentiate groups of analyzed samples. Five volatile compounds, i.e. ethanol, beta-myrcene, o-methyl styrene, 6-methyl-5-hepten-2-ol and 1-octanol, were found to be able to better discriminate between uncontaminated and contaminated samples. Prediction ability of the calculated model was estimated to be 100% by the "leave-one-out" cross-validation. An electronic nose device was then used to analyze the same contaminated and not contaminated canned tomato samples. Preliminary results were compared with those obtained by dynamic headspace gas chromatography-mass spectrometry, showing a good agreement.

  14. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  15. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    Science.gov (United States)

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  16. Selective pressurized liquid extraction of estrogenic compounds in soil and analysis by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Zulin; Rhind, Stewart M; Kerr, Christine; Osprey, Mark; Kyle, Carol E

    2011-01-24

    A selective pressurized liquid extraction (SPLE) method, followed by gas chromatography-mass spectrometry (GC-MS), for the simultaneous extraction and clean-up of estrone (E1), 17β-estradiol (E2), 17α-ethynylestradiol (EE2), estriol (E3) and bisphenol A (BPA) from soil samples is described. The on-line clean-up of soil by SPLE was achieved using different organic matter retainers, including silica, alumina and Florisil, the most effective being silica. Thus, different amounts of silica, in conjunction with different extraction solvents (acetone, ethyl acetate, isohexane and dichloromethane), either alone or in combination, were used to extract the target chemicals from spiked soil samples. It was shown that 3g silica resulted in satisfactory rates of recovery of target compounds and acetone:dichloromethane (1:3, v/v) was efficient in extracting and eluting estrogenic compounds for SPLE. Variables affecting the SPLE efficiency, including temperature and pressure were studied; the optimum parameters were 60°C and 1500 psi, respectively. The limits of detection (LODs) of the proposed method were 0.02-0.37 ng g(-1) for the different estrogenic chemicals studied. The outputs using the proposed method were linear over the range from 0.1 to 120 ng g(-1) for E1, E2, EE2, 0.2-120 ng g(-1) for E3, and 0.5-120 ng g(-1) for BPA. The optimized method was further verified by performing spiking experiments in natural soil matrices; good rates of recovery and reproducibility were achieved for all selected compounds and the method was successfully applied to soil samples from Northeast Scotland, for the determination of the target compounds.

  17. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  18. Pyrolysis - gas chromatography - mass spectrometry of lignins

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F.; Saiz-Jimenez, C.; Gonzalez-Vila, F.J.

    1979-01-01

    Milled wood lignins from spruce, beech and bamboo were pyrolysed. The high-boiling products of pyrolysis were studied by GLC and mass spectrometry. The forty-three products identified provide information on the structural units of lignin.

  19. Microextraction and Gas Chromatography/Mass Spectrometry for improved analysis of geosmin and other fungal "off" volatiles in grape juice.

    Science.gov (United States)

    Morales-Valle, H; Silva, L C; Paterson, R R M; Oliveira, J M; Venâncio, A; Lima, N

    2010-10-01

    Geosmin is a volatile fungal metabolite with an earthy aroma produced in grape products from rotten grapes. The accumulation of geosmin in grapes is caused by the interaction of Botrytis cinerea and Penicillium expansum. Solid Phase Microextraction (SPME) has great utility for collecting volatile compounds in wine. However, contamination with earthy odours may have occurred previously in the must and novel methods are required for this commodity. In the present report, several parameters of the SPME were evaluated to optimize geosmin extraction. The method permitted quantification of geosmin and other fungal volatiles by Gas Chromatography-Mass Spectrometer (GC-MS) at very low concentrations. Limits of detection and quantification (L(D) and L(Q)) for geosmin were 4.7 ng L(-1) and 15.6 ng L(-1) respectively. The RSD was 4.1% and the recovery rates ranged from 115% to 134%. Uniquely, haloanisoles were analyzed by using only one internal standard (2,3,6-trichloroanisole) thus avoiding the synthesis of deuterated anisole analogues that are used as internal standard in other methods. The method was used for the analysis of grape juice samples inoculated with B. cinerea and P. expansum. Geosmin and methylisoborneol were the compounds that appeared to contribute most to earthy odours, although other fungal compounds which are claimed to cause earthy or mouldy off-odours were detected (e.g. 1-octen-3-ol and fenchol).

  20. Rapid analysis of fatty acid profiles in raw nuts and seeds by microwave-ultrasonic synergistic in situ extraction-derivatisation and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Liu, Rui-Lin; Song, Shuang-Hong; Wu, Mei; He, Tian; Zhang, Zhi-Qi

    2013-12-15

    Based on microwave-ultrasonic synergistic in situ extraction-derivatisation (MUED), gas chromatography-mass spectrometry was proposed for rapid analysis of fatty acid profiles in raw nut and seed materials. Several critical experimental parameters for MUED, including reaction temperature, microwave power, amounts of catalyst and derivatisation reagent, have been optimised using response surface methodology. The results showed that the chromatographic peak areas of total fatty acids and the content of total unsaturated fatty acids obtained with MUED were markedly higher than those obtained by the conventional method (P<0.05 and P<0.01, respectively). The MUED method simplified the handling steps compared to the conventional procedure, shortened the sample preparation time whilst improving the extraction and derivatisation efficiency of lipids, and reduced oxidisation and decomposition of the unsaturated fatty acids. The simplicity, robustness and practicality of this method highlighted its significant potential for application in the rapid analysis of fatty acids in natural food resource samples.

  1. Studies on the metabolism and the toxicological analysis of the nootropic drug fipexide in rat urine using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Staack, Roland F; Maurer, Hans H

    2004-05-25

    Qualitative studies are described on the metabolism and the toxicological analysis of the nootropic fipexide (FIP) in rat urine using gas chromatography-mass spectrometry (GC-MS). FIP was extensively metabolized to 1-(3,4-methylenedioxybenzyl)piperazine (MDBP), 4-chlorophenoxyacetic acid, 1-[2-(4-chlorophenoxy)acetyl]piperazine, N-(4-hydroxy-3-methoxy-benzyl)piperazine, piperazine, N-(3,4-methylenedioxybenzyl)ethylenediamine, and N-[2-(4-chlorophenoxy)acetyl]ethylenediamine. The authors' systematic toxicological analysis (STA) procedure using full-scan GC-MS after acid hydrolysis of one urine aliquot, liquid-liquid extraction and acetylation allowed the detection of FIP via its metabolites in rat urine after administration of a common FIP dose. Therefore, this qualitative procedure should also be suitable for detection of a FIP intake in human urine. Differentiation of an intake of FIP from that of other drugs which form common metabolites is discussed.

  2. Carbon isotope ratio analysis of organic moieties from fossil mummified wood: establishing optimum conditions for off-line pyrolysis extraction using gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Poole, I.J.; Bergen, P.F. van

    2002-01-01

    Mummified fossil wood was studied using off-line pyrolysis-gas chromatography/mass spectrometry to reveal detailed insights into the pyrolysis conditions that are needed to obtain simultaneously sufficient amounts of both cellulose and lignin markers for stable carbon isotope analyses. The off-line

  3. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    Science.gov (United States)

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  4. Odor and odorous chemical emissions from dairy and swine facilities: Part 5-Simultaneous chemical and sensory analysis with Gas Chromatography - Mass Spectrometry - Olfactometry

    Science.gov (United States)

    Simultaneous chemical and sensory analyses using gas chromatography-mass spectrometry-olfactometry (GC-MS-O) for air samples collected at barn exhaust fans were used for quantification and ranking of odor impact of target odorous gases. Fifteen target odorous VOCs (odorants) were selected. Air sampl...

  5. Analysis of Mixed Aryl/Alkyl Esters by Pyrolysis Gas Chromatography-Mass Spectrometry in the Presence of Perchlorate

    Science.gov (United States)

    Burton, A. S.; Locke, D. R.; Lewis, E. K.

    2017-01-01

    Mars is an important target for Astrobiology. A key goal of the MSL mission was to determine whether Mars was habitable in the past, a que-tion that has now been definitely determined to be yes. Another key goal for Mars exploration is to understand the origin and distribution of organic material on Mars; this question is being addressed by the SAM instrument on MSL, and will also be informed by two upcoming Mars exploration missions, ExoMars and Mars 2020. These latter two missions have instrumentation capable of detecting and characterize organic molecules. Over the next decade, these missions will analyze organics in surface, near-surface and sub-surface samples. Each mission has the capability to analyze organics by different methods (pyrolysis gas chromatography-mass spectrometry [py-GC-MS]; laser desorption and thermal volatilization GC-MS; and Raman spectroscopy). Plausibly extraterrestrial organics were recently discovered by the Mars Science Laboratory (MSL), providing an important first step towards understanding the organic inventory on Mars [1]. The compounds detected were chlorobenzenes and chloroalkanes, but it was argued that chlorination of these compounds occurred during pyrolysis of samples containing unchlorinated organics in the presence of perchlorate. A recent report analyzed a suite of aromatic (benzene, toluene, benzoic acid, phthalic acid, and mellitic acid) and aliphatic (acetic acid, propane, propanol, and hexane) by pyrolysis under SAM-like conditions in the presence of perchlorate to attempt to constrain possible precursor molecules for the organic molecules detected on Mars. For aromatic compounds, the aromatic acids all readily produced SAM-relevant chlorobenzes, whereas benzene and toluene did not. This observation suggests that the chlorobenzene detected on Mars could have derived from compounds like mellitic acid, consistent with the previous hypothesis by Benner et al. [3]. Among the aliphatic molecules, it was shown that

  6. Triclosan and methyl-triclosan monitoring study in the northeast of Spain using a magnetic particle enzyme immunoassay and confirmatory analysis by gas chromatography mass spectrometry

    Science.gov (United States)

    Kantiani, Lina; Farré, Marinella; Asperger, Danijela; Rubio, Fernando; González, Susana; López de Alda, Maria J.; Petrović, Mira; Shelver, Weilin L.; Barceló, Damià

    2008-10-01

    SummaryFor the first time, the occurrence of triclosan and its metabolite methyl-triclosan was investigated in a typical Mediterranean area using a two-step methodology based on screening using a magnetic particle immunoassay (IA) and confirmatory analysis by solid phase extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS). In this study, 95 environmental samples were analyzed. A commercial immunoassay was assessed for use in the different types of water selected for this study. A large monitoring study was performed on the influent and the effluent of eight wastewater treatment plants (WWTPs), water samples from Ebro and Llobregat rivers, and drinking water. All wastewater samples tested in this study (influents and effluents) showed the presence of triclosan, with concentrations for raw influents being high (10 μg/L as average value). The percentages of triclosan removal for the WWTPs were evaluated (30-70%) along the different treatment processes showing that the best removal rates were obtained by the processes equipped with membrane bioreactors (MBRs). However, important concentrations of triclosan were detected even after treatment by MBRs. The presence of this biocide was confirmed in 50% of the river samples analyzed. Twenty two drinking water samples from the Barcelona city area were investigated, and in this case no triclosan was detected. Due to its properties and the widespread usage of triclosan, there is a need for monitoring and controlling the amounts present in wastewater effluents, river water, drinking water catchments areas, and drinking water. To this end, we present a feasible methodology using a magnetic particle-based immunoassay as a screening, followed by confirmatory analysis using solid phase extraction-gas chromatography-mass spectrometry (SPE-GC-MS).

  7. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-04-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry (MHSE), respectively. The monoterpenes were 1st extracted by means of supercritical fluid extraction (SFE) and analyzed by an optimized DHS-GC-MS. The optimization of the dynamic extraction step and the desorption/cryo-focusing step were tackled independently by experimental design assays. The best working conditions were set at 30 °C for the incubation temperature, 5 min of incubation time, and 40 mL of purge volume for the dynamic extraction step of these bioactive molecules. The conditions of the desorption/cryo-trapping step from the Tenax TA trap were set at follows: the temperature was increased from 30 to 300 °C at 150 °C/min, although the cryo-trapping was maintained at -70 °C. In order to estimate the efficiency of the SFE process, the analysis of monoterpenes in the 4 aromatic plants was directly carried out by means of MHSE because it did not require any sample preparation. Good linearity (r2) > 0.99) and reproducibility (relative standard deviation % <12) was obtained for solid and liquid quantification approaches, in the ranges of 0.5 to 200 ng and 10 to 500 ng/mL, respectively. The developed methods were applied to analyze the concentration of 7 monoterpenes in aromatic plants obtaining concentrations in the range of 2 to 6000 ng/g and 0.25 to 110 μg/mg, respectively.

  8. Rapid differentiation of three Chamaecyparis species (Cupressaceae) grown in Taiwan using solid-phase microextraction-gas chromatography/mass spectrometry, cluster analysis, and principal component analysis.

    Science.gov (United States)

    Lin, Chun-Ya; Chen, Ying-Ju; Cheng, Sen-Sung; Chang, Shang-Tzen

    2011-10-26

    Three Chamaecyparis species (C. formosensis, C. obtusa, and C. obtusa var. formosana) are difficult to distinguish by the naked eye. Therefore, from the chemotaxonomic point of view, it would be valuable to find a simple and rapid method to differentiate these three Chamaecyparis species. In this study, the chemical compositions of biogenic volatile organic compounds (BVOCs) from mature leaves were analyzed using solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS). Then cluster analysis (CA) and principal component analysis (PCA) were conducted for the BVOC constituents to reveal the differences among these three species. Results from SPME-GC/MS showed that the compositions of BVOCs from the three species were distinctly different. Moreover, these species were clearly differentiated according to the results of CA and PCA. In conclusion, the findings of this study suggest that SPME-GC/MS coupled with CA and PCA is a feasible and rapid technique to differentiate Chamaecyparis species with similar morphological characteristics.

  9. Analysis of Volatile Metabolites Released by Staphylococcus Aureus using Gas Chromatography-Mass Spectrometry and Determination of its Antifungal Activity

    Directory of Open Access Journals (Sweden)

    Hayfaa Hussein Jaddoa

    2016-08-01

    Full Text Available Bacterial volatile organic compounds (VOCs have been considered as sensitive and specific biomarkers for bacterial detection in human specimens and culture media. The possibility of using VOCs markers as one of the largest groups of bacterial metabolites would open a new frontier for developing more efficient techniques in the diagnosis of bacterial infections. The aims of this research were analysis of the bioactive chemical products and evaluation of antibacterial and antifungal activity. Bioactives (chemical compounds often referred to as secondary metabolites were analyzed using gas chromatography-mass spectroscopy (GC-MS techniques, then the in vitro antibacterial and antifungal activity of the methanolic extract was evaluated. Thirty five bioactive compounds were identified in the methanolic extract of Staphylococcus aureus. GC-MS analysis of Staphylococcus aureus revealed the existence of the: Hexanoic acid , 2-methyl, 12,15-Octadecadiynoic acid , methyl ester, 1-Aminononadecane ,N-trifluoroacetyl-, N-[3-[N-Aziridyl]propylidene]hexylamine, N-(2,5-Dicyano-3,4-dihydro-2H-pyrrol-2-yl-acetamide, 3-Cyclohex-3-enyl-propionic acid, 1-Methyl-4-[nitromethyl]-4-piperidinol, 3-Azonia-5-hexyn-1-ol , N,N-dimethyl-O-acetyl-,bromide, 1-Hexadecanol -2-methyl-, 1-Propyl-3,6-diazahomoadamantan, 9-Borabicyclo[3.3.1]nonane , 9-mercapto-, Benzyl methyl ketone, L-Aspartic acid ,N-glycyl-, Aminoacetamide , N-methyl-N-[4-(1-pyrrolidinyl-2-butynyl]-, Tertbutyloxyformamide , N-methyl-N-[4-(1-pyrrolidinyl-2-butyn, 5,7-Dodecadiyn-1,12-diol, Deoxyspergualin, D-Streptamine , O-6-deoxy-α-D-glucopyranosyl-(1-4, dl-Citrulline, N-[3-Diethylaminopropyl]-4-oxo-1,2,3,4,5,6,7,8-octahydroqui, N-Propionyl-D-glucoseamine, Cystine, 3,4-Dihydrocoumarin ,6-fluoro-4,4-dimethyl-, 4-(2,5-Dihydro-3-methoxyphenylbutylamine, 3-methoxy-2-(1-methylethyl-5-(2-methylpropylpyrazine, Uric acid, Thiocyanic acid 4-methoxy-2,6-dimethyl-3-pyridyl ester, 12-Dimethylamino-10-oxododecanoic acid

  10. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Willemse, S.; Zeng, T.; Asten, A. van; Koeberg, M.; Heijden, A.E.D.M. van der; Bolck, A.; Schoenmakers, P.

    2014-01-01

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times the analysis of impurities in TNT was performed in

  11. Comparative analysis of essential oils found in Rhizomes Curcumae and Radix Curcumae by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Di-Ya Lu; Yan Cao; Ling Li; Zhen-Yu Zhu; Xin Dong; Hai Zhang; Yi-Feng Chai; Zi-Yang Lou

    2011-01-01

    A comparison of the volatile compounds in Rhizomes Curcumae (Ezhu) and Radix Curcumae (Yujin) was undertaken using gas chromatography mass spectrometi-y (GC-MS). Ultrasonic extraction and GC-MS methods were developed for the simultaneous determination of five sesquiterpenes, namely, α-pinene, β-elemene, curcumol, germacrone and curdione, in Ezhu and Yunjin. Good linearity (r〉0.999) and high inter-day precision were observed over the investigated concentration ranges. The validated method was successfully used for the simultaneous determination of five sesquiterpenes in Ezhu and Yujin. The quantitative method can be effectively used to evaluate and monitor the quality of Chinese curcuma in clinical use.

  12. Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón Fernando; del Carmen Estrada-Montoya, María

    2004-09-08

    Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

  13. Analysis of liposoluble carboxylic acids metabolome in human serum by stable isotope labeling coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zhu, Quan-Fei; Zhang, Zheng; Liu, Ping; Zheng, Shu-Jian; Peng, Ke; Deng, Qian-Yun; Zheng, Fang; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-08-19

    Fatty acids (FAs) are groups of liposoluble carboxylic acids (LCAs) and play important roles in various physiological processes. Abnormal contents or changes of FAs are associated with a series of diseases. Here we developed a strategy with stable isotope labeling combined with liquid chromatography-tandem mass spectrometry (IL-LC-MS) analysis for comprehensive profiling and relative quantitation of LCAs in human serum. In this strategy, a pair of isotope labeling reagents (2-dimethylaminoethylamine (DMED)) and d4-2-dimethylaminoethylamine (d4-DMED) were employed to selectively label carboxyl groups of LCAs. The DMED and d4-DMED labeled products can lose four characteristic neutral fragments of 45 and 49Da or 63 and 67Da in collision-induced dissociation. Therefore, quadruple neutral loss scan (QNLS) mode was established and used for non-targeted profiling of LCAs. The peak pairs of DMED and d4-DMED labeling with the same retention time, intensity and characteristic mass differences were extracted from the two NLS spectra respectively, and assigned as potential LCA candidates. Using this strategy, 241 LCA candidates were discovered in the human serum; 156 carboxylic acid compounds could be determined by searching HMDB and METLIN databases (FAs are over 90%) and 21 of these LCAs were successfully identified by standards. Subsequently, a modified pseudo-targeted method with multiple reaction monitoring (MRM) detection mode was developed and used for relative quantification of LCAs in human serum from type 2 diabetes mellitus (T2DM) patients and healthy controls. As a result, 81 LCAs were found to have significant difference between T2DM patients and healthy controls. Taken together, the isotope labeling combined with tandem mass spectrometry analysis demonstrated to be a powerful strategy for identification and quantification of LCA compounds in serum samples.

  14. A micellar electrokinetic chromatography-mass spectrometry approach using in-capillary diastereomeric derivatization for fully automatized chiral analysis of amino acids.

    Science.gov (United States)

    Moldovan, Radu-Cristian; Bodoki, Ede; Kacsó, Timea; Servais, Anne-Catherine; Crommen, Jacques; Oprean, Radu; Fillet, Marianne

    2016-10-07

    In the context of bioanalytical method development, process automatization is nowadays a necessity in order to save time, improve method reliability and reduce costs. For the first time, a fully automatized micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) method with in-capillary derivatization was developed for the chiral analysis of d- and l-amino acids using (-)-1-(9-fluorenyl) ethyl chloroformate (FLEC) as labeling reagent. The derivatization procedure was optimized using an experimental design approach leading to the following conditions: sample and FLEC plugs in a 2:1 ratio (15s, 30mbar: 7.5s, 30mbar) followed by 15min of mixing using a voltage of 0.1kV. The formed diastereomers were then separated using a background electrolyte (BGE) consisting of 150mM ammonium perfluorooctanoate (APFO) (pH=9.5) and detected by mass spectrometry (MS). Complete chiral resolution was obtained for 8 amino acids, while partial separation was achieved for 6 other amino acid pairs. The method showed good reproducibility and linearity in the low micromolar concentration range. The applicability of the method to biological samples was tested by analyzing artificial cerebrospinal fluid (aCSF) samples.

  15. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  16. Simultaneous Organic and Inorganic Analysis of Colored Oriental Lacquerware by Pyrolysis-Gas Chromatography/Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yoshimi Kamiya

    2015-01-01

    Full Text Available Organic analysis and inorganic analysis are generally based on different physical principles, and for this reason it is difficult to analyze resins and pigments simultaneously. For these reasons, we have performed Py-GC/MS measurements of red-, yellow-, and green-colored lacquer films applied to lacquerware items to assess the feasibility of simultaneously detecting resin ingredients together with certain pigments. We have also compared our findings to the results of SEM-EDS, X-ray fluorescence spectrometry (XRF, and X-ray diffractometry (XRD measurements. XRD analysis yielded molecular-level information (information on binding states regarding mercury (Hg and iron (Fe; however, the information obtained for arsenic (As and sulfur (S was insufficient. In contrast, Py-GC/MS analyses simultaneously yielded molecular-level information on arsenic (As and sulfur (S together with detection of the primary ingredients of the lacquer. For this reason, it shows that several pieces of information is provided easily and quickly when the colored lacquer cultural heritage is measured using the Py-GC/MS method.

  17. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Feng

    2013-01-01

    Full Text Available Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  18. Atmospheric Pressure Chemical Ionization Gas Chromatography Mass Spectrometry for the Analysis of Selected Emerging Brominated Flame Retardants in Foods

    Science.gov (United States)

    Lv, Surong; Niu, Yumin; Zhang, Jing; Shao, Bing; Du, Zhenxia

    2017-03-01

    Emerging brominated flame retardants (eBFRs) other than polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls (PBBs) and their derivatives in foods have been in focus in recent years due to their increasing production volumes, indefinite information on toxicities and the lack of data on occurrence in environments, foods as well as humans. In this study, gas chromatography was coupled to an atmospheric pressure chemical ionization-tandem mass spectrometry (APGC-MS/MS) for the analysis of six eBFRs in pork, chicken, egg, milk and fish. A short section of unpacked capillary column coupled to the end of the analytical column was applied to improve the chromatographic behaviors of high boiling point compounds. The method was comprehensively validated with method limit of quantification (mLOQ) lower than 8 pg/g wet weight (w.w.). Samples from Chinese Total Diet study were quantified following the validated APGC-MS/MS method. 2,3,4,5-pentabromo-6-ethylbenzene (PBEB), hexabromobenzene (HBB), pentabromotoluene (PBT) and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) were most frequently detected in samples. The highest concentration was found in fish with 351.9 pg/g w.w. of PBT. This is the first report on the presence of PBT in food samples with non-ignorable concentrations and detection rate.

  19. Analysis of organic acids in fruit juices by liquid chromatography-mass spectrometry: an enhanced tool for authenticity testing.

    Science.gov (United States)

    Ehling, Stefan; Cole, Shannon

    2011-03-23

    Organic acid analysis plays a fundamental role in the testing of authenticity of fruit juices. Analytical methods used routinely for organic acids suffer from poor reproducibility, often give false positives/negatives for tartaric acid, and do not offer the possibility of analyte confirmation. There are conflicting reports in the literature on the presence/absence of tartaric acid in pomegranate juice, a potential indicator of adulteration with grape juice. In this work, a method based on stable isotope dilution liquid chromatography-tandem mass spectrometry is described for citric, malic, quinic, and tartaric acid in fruit juices. Validation data including precision and recovery in six types of juice are presented. Tartaric and quinic acids were confirmed in pomegranate juice at concentrations of 1-5 and ∼1 mg/L, respectively. These concentrations are much lower than those resulting from adulteration with grape juice and apple juice, respectively, at the 5% level. A separate method for isocitric acid in orange juice based on the single standard addition method is also described.

  20. Simultaneous analysis of some club drugs in whole blood using solid phase extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Castro, André L; Tarelho, Sónia; Silvestre, Armando; Teixeira, Helena M

    2012-02-01

    The use of psychoactive substances to improve social relations and increase body energy, in Rave Culture, has raised many legal and health public concerns, both for illicit trade and consumption. Therefore, forensic toxicology plays an important role in this area, mainly linked to the detection and quantitation of these substances, both in vivo and in post-mortem samples. In fact, at the moment, forensic sciences have been under public authorities' scrutiny and critical look, due to the increasing attention of the media and public opinion, always applying for the use of scientific knowledge to help solving forensic cases. However, forensic toxicology results are only reliable to solve legal cases if all the analytical methodologies used are appropriately validated. In this work, a methodology for the extraction and analysis of 7-aminoflunitrazepam, buprenorphine, flunitrazepam, ketamine, methadone, phencyclidine (PCP) and d-propoxyphene was developed for whole blood samples, with solid phase extraction (SPE), using OASIS(®) MCX SPE columns, and gas chromatography coupled to mass spectrometry. The procedure presented here proved to be reliable, specific, selective and sensitive, with good LODs and LOQs and good precision.The adoption of a SPE procedure with an automatic SPE extraction device, allowed an increased level of automation in sample treatment, being contemporarily less time-consuming, increasing productiveness, and allowing good recovery and appropriate selectivity being, also, simple and reproducible. The simultaneous detection and quantitation of all compounds by the same extraction and detection methodology is crucial and has a great potential for forensic toxicology and clinical analysis.

  1. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi, E-mail: yqfeng@whu.edu.cn

    2016-01-28

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d{sub 5}-Girard reagent P (d{sub 5}-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones

  2. Development of a fast extraction method and optimization of liquid chromatography-mass spectrometry for the analysis of phenolic compounds in lentil seed coats.

    Science.gov (United States)

    Mirali, Mahla; Ambrose, Stephen J; Wood, Stephen A; Vandenberg, Albert; Purves, Randy W

    2014-10-15

    A systematic set of optimization experiments was conducted to design an efficient extraction and analysis protocol for screening six different sub-classes of phenolic compounds in the seed coat of various lentil (Lens culinaris Medik.) genotypes. Different compounds from anthocyanidins, flavan-3-ols, proanthocyanidins, flavanones, flavones, and flavonols sub-classes were first optimized for use as standards for liquid chromatography mass spectrometry (LC-MS) with UV detection. The effect of maceration duration, reconstitution solvent, and extraction solvent were investigated using lentil genotype CDC Maxim. Chromatographic conditions were optimized by examining column separation efficiencies, organic composition, and solvent gradient. The results showed that a 1h maceration step was sufficient and that non-acidified solvents were more appropriate; a 70:30 acetone: water (v/v) solvent was ultimately selected. Using a Kinetex PFP column, the organic concentration, gradient, and flow rate were optimized to maximize the resolution of phenolic compounds in a short 30-min analysis time. The optimized method was applied to three lentil genotypes with different phenolic compound profiles to provide information of value to breeding programs.

  3. Gas chromatography-mass spectrometry following microwave distillation and headspace solid-phase microextraction for fast analysis of essential oil in dry traditional Chinese medicine.

    Science.gov (United States)

    Li, Ning; Deng, Chunhui; Li, Yan; Ye, Hao; Zhang, Xiangmin

    2006-11-10

    In this paper, a novel method based on gas chromatography-mass spectrometry (GC-MS) following microwave distillation-headspace solid-phase microextraction (MD-HS-SPME) was developed for the determination of essential oil in dry traditional Chinese medicine (TCM). TCM is dried before being preserved and used, there is too little water to absorb microwave energy and heat the TCM samples. In the work, carbonyl iron powders (CIP) was added and mixed with the dried TCM sample, which was used as microwave absorption solid medium for dry distillation of the TCM. At the same time, SPME was used for the extraction and concentration of essential oil after MD. The dry rhizomes of Atractylodes lancea DC was used as the model TCM, and used in the study. The MD-HS-SPME parameters including fiber coating, microwave power, irradiation time, and the amount of added CIP, were studied. To demonstrate the method feasibility, the conventional HS-SPME method was also used for the analysis of essential oil in the TCM. Experimental results show that more compounds were isolated and identified by MD-HS-SPME than those by HS-SPME. Compared to conventional HS-SPME, the advantages of the proposed method are: short extraction time and high extraction efficiency. All experimental results show that the proposed method is an alternative tool for fast analysis of essential oils in dry TCMs.

  4. Development of solid-phase microextraction followed by gas chromatography-mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke.

    Science.gov (United States)

    Ye, Qing

    2008-12-12

    In this work, a novel, simple and efficient method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed to the analysis of volatile organic chemicals (VOCs) in mainstream cigarette smoke (MCS). Using a simple home-made smoking machine device, extraction and concentration of VOCs in MCS were performed by SPME fiber, and the VOCs adsorbed on fiber were desorbed, and analyzed by GC-MS. The extraction fiber types and the desorption conditions were studied, and the method precision was also investigated. After the investigation, the optimal fiber was divinylbenzene/carboxen/polydemethylsiloxane (DVB/CAR/PDMS), and the optimal desorption condition was 250 degrees C for 3 min. The method precision was from 2% to 11%. Finally, the proposed method was tested by its application of the analysis of VOCs in MCS from 10 brands of cigarettes and one reference cigarette. A total of 70 volatile compounds were identified by the proposed method. The experimental results showed that the proposed method was a simple, rapid, reliable, and solvent-free technique for the determination of VOCs in MCS.

  5. Analysis of dialkyl phosphate metabolites in hair using gas chromatography-mass spectrometry: a biomarker of chronic exposure to organophosphate pesticides.

    Science.gov (United States)

    Margariti, Maria G; Tsatsakis, Aristidis M

    2009-05-01

    The aim of our study was to develop and validate an analytical approach for the quantitative determination of three dialkyl phosphate (DAP) metabolites, dimethyl phosphate (DMP), dimethyl thiophosphate (DMTP) and diethyl phosphate (DEP), of organophosphate pesticides (OPs) in hair samples. The proposed methodology comprises a decontamination step, solid-liquid extraction, followed by liquid-liquid extraction, pentafluorobenzyl bromide derivatization, clean-up on Florisil/PSA column and analysis by gas chromatography-mass spectrometry (GC-MS). Extraction recovery, obtained from 50 mg hair samples spiked at two concentration levels, ranged from 56.1 to 107.9% and the within-day precision ranged from 13.5 to 17.5%. Limits of detection (LODs) ranged from 0.02 to 0.10 ng mg(-1). The results obtained from the analysis of hair samples of 30 agricultural workers show the suitability of the proposed method for monitoring people occupationally exposed to OPs. The most frequently detected compound was DEP followed by DMP. This is the first report on the detection of dialkyl phosphates in human hair which reflects the ability of hair testing to assess chronic exposure to OPs.

  6. Use of hydrogen as a carrier gas for the analysis of steroids with anabolic activity by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Muñoz-Guerra, J A; Prado, P; García-Tenorio, S Vargas

    2011-10-14

    Due to the impact in the media and the requirements of sensitivity and robustness, the detection of the misuse of forbidden substances in sports is a really challenging area for analytical chemistry, where any study focused on enhancing the performance of the analytical methods will be of great interest. The aim of the present study was to evaluate the usefulness of using hydrogen instead of helium as a carrier gas for the analysis of anabolic steroids by gas chromatography-mass spectrometry with electron ionization. There are several drawbacks related with the use of helium as a carrier gas: it is expensive, is a non-renewable resource, and has limited availability in many parts of the world. In contrast, hydrogen is readily available using a hydrogen generator or high-pressure bottled gas, and allows a faster analysis without loss of efficiency; nevertheless it should not be forgotten that due to its explosiveness hydrogen must be handled with caution. Throughout the study the impact of the change of the carrier gas will be evaluated in terms of: performance of the chromatographic system, saving of time and money, impact on the high vacuum in the analyzer, changes in the fragmentation behaviour of the analytes, and finally consequences for the limits of detection achieved with the method.

  7. Characterization of Penicillium species isolated from grape berries by their internal transcribed spacer (ITS1) sequences and by gas chromatography-mass spectrometry analysis of geosmin production.

    Science.gov (United States)

    La Guerche, Stéphane; Garcia, Carole; Darriet, Philippe; Dubourdieu, Denis; Labarère, Jacques

    2004-06-01

    Geosmin (trans-1,10-dimethyl-trans-9-decalol), an earthy-musty compound, has been identified in wines and in grape juice, in which its presence is highly detrimental to the aromatic quality. Geosmin has a biological origin, and the analysis of rotten grape microflora has been done on two grape varieties (Semillon, Cabernet Sauvignon) from six parcels of the Bordeaux region over 3 years (1999, 2000, 2001). Forty-three Penicillium-related species have been analyzed by gas chromatography-mass spectrometry (GC-MS) for their geosmin production. GC-MS analysis has demonstrated that the earthy odor was always correlated with the presence of geosmin. Phenotypic characterization of Penicillium spp. being ambiguous, a molecular characterization by rDNA internal transcribed spacer (ITS1) sequencing was performed for all strains. The results evidenced that all strains producing geosmin belonged to only one species, P. expansum, and that the other strains, not producing geosmin, belonged to three species: P. purpurogenum, P. thomii, and Talaromyces wortmanii.

  8. Simple and sensitive analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Namera, A; Watanabe, T; Yashiki, M; Kojima, T; Urabe, T

    1999-03-01

    A simple method for the analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) is developed. A vial containing a serum sample, 5M sodium hydroxide, and benzylacetone (internal standard) is heated to 70 degrees C, and an SPME fiber is exposed for 30 min in the headspace of the vial. The compounds extracted by the fiber are desorbed by exposing the fiber in the injection port of the GC-MS. The calibration curves show linearity in the range of 0.05-5.0 micrograms/mL for nereistoxin and N-methyl-N-(2-methylthio-1-methylthiomethyl)ethylamine, 0.01-5.0 micrograms/mL for S,S'-dimethyl dihydronereistoxin, and 0.5-10 micrograms/mL for 2-methylthio-1-methylthiomethylethylamine in serum. No interferences are found, and the analysis time is 50 min for one sample. In addition, this proposed method is applied to a patient who attempted suicide by ingesting Padan 4R, a herbicide. Padan 4R contains 4% cartap hydrochloride, which is an analogue of nereistoxin. Nereistoxin and its metabolites are detected in the serum samples collected from the patient during hospitalization. The concentration ranges of nereistoxin in the serum are 0.09-2.69 micrograms/mL.

  9. Seized cannabis seeds cultivated in greenhouse: A chemical study by gas chromatography-mass spectrometry and chemometric analysis.

    Science.gov (United States)

    Mariotti, Kristiane de Cássia; Marcelo, Marcelo Caetano Alexandre; Ortiz, Rafael S; Borille, Bruna Tassi; Dos Reis, Monique; Fett, Mauro Sander; Ferrão, Marco Flôres; Limberger, Renata Pereira

    2016-01-01

    Cannabis sativa L. is cultivated in most regions of the world. In 2013, the Brazilian Federal Police (BFP) reported 220 tons of marijuana seized and about 800,000 cannabis plants eradicated. Efforts to eradicate cannabis production may have contributed to the development of a new form of international drug trafficking in Brazil: the sending of cannabis seeds in small amounts to urban centers by logistics postal. This new and increasing panorama of cannabis trafficking in Brazil, encouraged the chemical study of cannabis seeds cultivated in greenhouses by gas-chromatography coupled with mass spectrometry (GC-MS) associated with exploratory and discriminant analysis. Fifty cannabis seeds of different varieties and brands, seized by the BFP were cultivated under predefined conditions for a period of 4.5 weeks, 5.5 weeks, 7.5 weeks, 10 weeks and 12 weeks. Aerial parts were analyzed and cannabigerol, cannabinol, cannabidiol, cannabichromene Δ9-tetrahydrocannabinol (THC) and other terpenoids were detected. The chromatographic chemical profiles of the samples were significantly different, probably due to different variety, light exposition and age. THC content increased with the age of the plant, however, for other cannabinoids, this correlation was not observed. The chromatograms were plotted in a matrix with 50 rows (samples) and 3886 columns (abundance in a retention time) and submitted to PCA, HCA and PLS-DA after pretreatment (normalization, first derivative and autoscale). The PCA and HCA showed age separation between samples however it was not possible to verify the separation by varieties and brands. The PLS-DA classification provides a satisfactory prediction of plant age.

  10. Ultraperformance liquid chromatography-mass spectrometry based comprehensive metabolomics combined with pattern recognition and network analysis methods for characterization of metabolites and metabolic pathways from biological data sets.

    Science.gov (United States)

    Zhang, Ai-hua; Sun, Hui; Han, Ying; Yan, Guang-li; Yuan, Ye; Song, Gao-chen; Yuan, Xiao-xia; Xie, Ning; Wang, Xi-jun

    2013-08-06

    Metabolomics is the study of metabolic changes in biological systems and provides the small molecule fingerprints related to the disease. Extracting biomedical information from large metabolomics data sets by multivariate data analysis is of considerable complexity. Therefore, more efficient and optimizing metabolomics data processing technologies are needed to improve mass spectrometry applications in biomarker discovery. Here, we report the findings of urine metabolomic investigation of hepatitis C virus (HCV) patients by high-throughput ultraperformance liquid chromatography-mass spectrometry (UPLC-MS) coupled with pattern recognition methods (principal component analysis, partial least-squares, and OPLS-DA) and network pharmacology. A total of 20 urinary differential metabolites (13 upregulated and 7 downregulated) were identified and contributed to HCV progress, involve several key metabolic pathways such as taurine and hypotaurine metabolism, glycine, serine and threonine metabolism, histidine metabolism, arginine and proline metabolism, and so forth. Metabolites identified through metabolic profiling may facilitate the development of more accurate marker algorithms to better monitor disease progression. Network analysis validated close contact between these metabolites and implied the importance of the metabolic pathways. Mapping altered metabolites to KEGG pathways identified alterations in a variety of biological processes mediated through complex networks. These findings may be promising to yield a valuable and noninvasive tool that insights into the pathophysiology of HCV and to advance the early diagnosis and monitor the progression of disease. Overall, this investigation illustrates the power of the UPLC-MS platform combined with the pattern recognition and network analysis methods that can engender new insights into HCV pathobiology.

  11. High performance liquid chromatography-mass spectrometry analysis of high antioxidant australian fruits with antiproliferative activity against cancer cells

    Directory of Open Access Journals (Sweden)

    Joseph Sirdaarta

    2016-01-01

    Abbreviations used: DPPH: di (phenyl- (2,4,6-trinitrophenyl iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. Ian Edwin Cock

  12. Supported liquid membrane-liquid chromatography-mass spectrometry analysis of cyanobacterial toxins in fresh water systems

    Science.gov (United States)

    Mbukwa, Elbert A.; Msagati, Titus A. M.; Mamba, Bhekie B.

    Harmful algal blooms (HABs) are increasingly becoming of great concern to water resources worldwide due to indiscriminate waste disposal habits resulting in water pollution and eutrophication. When cyanobacterial cells lyse (burst) they release toxins called microcystins (MCs) that are well known for their hepatotoxicity (causing liver damage) and have been found in eutrophic lakes, rivers, wastewater ponds and other water reservoirs. Prolonged exposure to low concentrated MCs are equally of health importance as they are known to be bioaccumulative and even at such low concentration do exhibit toxic effects to aquatic animals, wildlife and human liver cells. The application of common treatment processes for drinking water sourced from HABs infested reservoirs have the potential to cause algal cell lyses releasing low to higher amounts of MCs in finished water. Trace microcystins in water/tissue can be analyzed and quantified using Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) following solid-phase extraction (SPE) sample clean-up procedures. However, extracting MCs from algal samples which are rich in chlorophyll pigments and other organic matrices the SPE method suffers a number of drawbacks, including cartridge clogging, long procedural steps and use of larger volumes of extraction solvents. We applied a supported liquid membrane (SLM) based technique as an alternative sample clean-up method for LC-ESI-MS analysis of MCs from both water and algal cells. Four (4) MC variants (MC-RR, -YR, -LR and -WR) from lyophilized cells of Microcystis aeruginosa and water collected from a wastewater pond were identified) and quantified using LC-ESI-MS following a SLM extraction and liquid partitioning step, however, MC-WR was not detected from water extracts. Within 45 min of SLM extraction all studied MCs were extracted and pre-concentrated in approximately 15 μL of an acceptor phase at an optimal pH 2.02 of the donor phase (sample). The highest

  13. Rapid analysis of Fructus forsythiae essential oil by ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jiao, Jiao; Ma, Dan-Hui; Gai, Qing-Yan; Wang, Wei; Luo, Meng; Fu, Yu-Jie; Ma, Wei

    2013-12-04

    A rapid, green and effective miniaturized sample preparation and analytical technique, i.e. ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction (ILAMD-HS-SDME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of essential oil (EO) in Fructus forsythiae. In this work, ionic liquids (ILs) were not only used as the absorption medium of microwave irradiation but also as the destruction agent of plant cell walls. 1-Ethyl-3-methylimidazolium acetate ([C2mim]OAc) was chosen as the optimal ILs. Moreover, n-heptadecane (2.0 μL) was selected as the appropriate suspended solvent for the extraction and concentration of EO. Extraction conditions of the proposed method were optimized using the relative peak area of EO constituents as the index, and the optimal operational parameters were obtained as follows: irradiation power (300 W), sample mass (0.7 g), mass ratio of ILs to sample (2.4), temperature (78°C) and time (3.4 min). In comparison to previous reports, the proposed method was faster and required smaller sample amount but could equally monitor all EO constituents with no significant differences.

  14. Ultrasonic nebulization extraction coupled with headspace single drop microextraction and gas chromatography-mass spectrometry for analysis of the essential oil in Cuminum cyminum L.

    Science.gov (United States)

    Wang, Lu; Wang, Ziming; Zhang, Huihui; Li, Xueyuan; Zhang, Hanqi

    2009-08-04

    A novel method for analysis of essential oil in Cuminum cyminum L. using simultaneous ultrasonic nebulization extraction and headspace single drop microextraction (UNE-HS-SDME) followed by gas chromatography-mass spectrometry was developed. Experimental parameters, including the kind of suspended solvent, microdrop volume, sample amount, extraction time, enrichment time and salt concentration were examined and optimized. Compared with hydrodistillation (HD), UNE-HS-SDME provides the advantages of a small amount of sample (50 mg), time-saving (20 min), simplicity, cheapness and low toxicity. In addition, UNE-HS-SDME also provided higher enrichment efficiency and sensitivity compared with stirring extraction (SE)-HS-SDME, ultrasonic assistant extraction (UAE) and UNE. Some constituents in the essential oil, were identified and the detection limits for beta-pinene, p-cymene and gamma-terpinene range from 6.67 pLL(-1) to 14.8 pLL(-1). The results indicated that the UNE-HS-SDME is simple and highly efficient extraction and enrichment technique.

  15. High-resolution gas chromatography/mass spectrometry method for characterization and quantitative analysis of ginkgolic acids in Ginkgo biloba plants, extracts, and dietary supplements.

    Science.gov (United States)

    Wang, Mei; Zhao, Jianping; Avula, Bharathi; Wang, Yan-Hong; Avonto, Cristina; Chittiboyina, Amar G; Wylie, Philip L; Parcher, Jon F; Khan, Ikhlas A

    2014-12-17

    A high-resolution gas chromatography/mass spectrometry (GC/MS) with selected ion monitor method focusing on the characterization and quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba L. plant materials, extracts, and commercial products was developed and validated. The method involved sample extraction with (1:1) methanol and 10% formic acid, liquid-liquid extraction with n-hexane, and derivatization with trimethylsulfonium hydroxide (TMSH). Separation of two saturated (C13:0 and C15:0) and six unsaturated ginkgolic acid methyl esters with different positional double bonds (C15:1 Δ8 and Δ10, C17:1 Δ8, Δ10, and Δ12, and C17:2) was achieved on a very polar (88% cyanopropyl) aryl-polysiloxane HP-88 capillary GC column. The double bond positions in the GAs were determined by ozonolysis. The developed GC/MS method was validated according to ICH guidelines, and the quantitation results were verified by comparison with a standard high-performance liquid chromatography method. Nineteen G. biloba authenticated and commercial plant samples and 21 dietary supplements purported to contain G. biloba leaf extracts were analyzed. Finally, the presence of the marker compounds, terpene trilactones and flavonol glycosides for Ginkgo biloba in the dietary supplements was determined by UHPLC/MS and used to confirm the presence of G. biloba leaf extracts in all of the botanical dietary supplements.

  16. Automated resolution of chromatographic signals by independent component analysis-orthogonal signal deconvolution in comprehensive gas chromatography/mass spectrometry-based metabolomics.

    Science.gov (United States)

    Domingo-Almenara, Xavier; Perera, Alexandre; Ramírez, Noelia; Brezmes, Jesus

    2016-07-01

    Comprehensive gas chromatography-mass spectrometry (GC×GC-MS) provides a different perspective in metabolomics profiling of samples. However, algorithms for GC×GC-MS data processing are needed in order to automatically process the data and extract the purest information about the compounds appearing in complex biological samples. This study shows the capability of independent component analysis-orthogonal signal deconvolution (ICA-OSD), an algorithm based on blind source separation and distributed in an R package called osd, to extract the spectra of the compounds appearing in GC×GC-MS chromatograms in an automated manner. We studied the performance of ICA-OSD by the quantification of 38 metabolites through a set of 20 Jurkat cell samples analyzed by GC×GC-MS. The quantification by ICA-OSD was compared with a supervised quantification by selective ions, and most of the R(2) coefficients of determination were in good agreement (R(2)>0.90) while up to 24 cases exhibited an excellent linear relation (R(2)>0.95). We concluded that ICA-OSD can be used to resolve co-eluted compounds in GC×GC-MS.

  17. A peaklet-based generic strategy for the untargeted analysis of comprehensive two-dimensional gas chromatography mass spectrometry data sets.

    Science.gov (United States)

    Egert, Björn; Weinert, Christoph H; Kulling, Sabine E

    2015-07-31

    Comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) is a well-established key technology in analytical chemistry and increasingly used in the field of untargeted metabolomics. However, automated processing of large GC×GC-MS data sets is still a major bottleneck in untargeted, large-scale metabolomics. For this reason we introduce a novel peaklet-based alignment strategy. The algorithm is capable of an untargeted deterministic alignment exploiting a density based clustering procedure within a time constrained similarity matrix. Exploiting minimal (1)D and (2)D retention time shifts between peak modulations, the alignment is done without the need for peak merging which also eliminates the need for linear or nonlinear retention time correction procedures. The approach is validated in detail using data of urine samples from a large human metabolomics study. The data was acquired by a Shimadzu GCMS-QP2010 Ultra GC×GC-qMS system and consists of 512 runs, including 312 study samples and 178 quality control sample injections, measured within a time period of 22 days. The final result table consisted of 313 analytes, each of these being detectable in at least 75% of the study samples. In summary, we present an automated, reliable and fully transparent workflow for the analysis of large GC×GC-qMS metabolomics data sets.

  18. Pyrolysis kinetic and product analysis of different microalgal biomass by distributed activation energy model and pyrolysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Xuewei; Zhang, Rui; Fu, Juan; Geng, Shu; Cheng, Jay Jiayang; Sun, Yuan

    2014-07-01

    To assess the energy potential of different microalgae, Chlorella sorokiniana and Monoraphidium were selected for studying the pyrolytic behavior at different heating rates with the analytical method of thermogravimetric analysis (TG), distributed activation energy model (DAEM) and pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS). Results presented that Monoraphidium 3s35 showed superiority for pyrolysis at low heating rate. Calculated by DAEM, during the conversion rate range from 0.1 to 0.7, the activation energies of C. sorokiniana 21 were much lower than that of Monoraphidium 3s35. Both C. sorokiniana 21 and Monoraphidium 3s35 can produce certain amount (up to 20.50%) of alkane compounds, with 9-Octadecyne (C18H34) as the primary compound. Short-chain alkanes (C7-C13) with unsaturated carbon can be released in the pyrolysis at 500°C for both microalgal biomass. It was also observed that the pyrolysis of C. sorokiniana 21 released more alcohol compounds, while Monoraphidium 3s35 produced more saccharides.

  19. Quantitative analysis of fatty-acid-based biofuels produced by wild-type and genetically engineered cyanobacteria by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Guan, Wenna; Zhao, Hui; Lu, Xuefeng; Wang, Cong; Yang, Menglong; Bai, Fali

    2011-11-11

    Simple and rapid quantitative determination of fatty-acid-based biofuels is greatly important for the study of genetic engineering progress for biofuels production by microalgae. Ideal biofuels produced from biological systems should be chemically similar to petroleum, like fatty-acid-based molecules including free fatty acids, fatty acid methyl esters, fatty acid ethyl esters, fatty alcohols and fatty alkanes. This study founded a gas chromatography-mass spectrometry (GC-MS) method for simultaneous quantification of seven free fatty acids, nine fatty acid methyl esters, five fatty acid ethyl esters, five fatty alcohols and three fatty alkanes produced by wild-type Synechocystis PCC 6803 and its genetically engineered strain. Data obtained from GC-MS analyses were quantified using internal standard peak area comparisons. The linearity, limit of detection (LOD) and precision (RSD) of the method were evaluated. The results demonstrated that fatty-acid-based biofuels can be directly determined by GC-MS without derivation. Therefore, rapid and reliable quantitative analysis of fatty-acid-based biofuels produced by wild-type and genetically engineered cyanobacteria can be achieved using the GC-MS method founded in this work.

  20. Optimization of two different dispersive liquid-liquid microextraction methods followed by gas chromatography-mass spectrometry determination for polycyclic aromatic hydrocarbons (PAHs) analysis in water.

    Science.gov (United States)

    Tseng, Wan-Chi; Chen, Pai-Shan; Huang, Shang-Da

    2014-03-01

    Novel sample preparation methods termed "up-and-down shaker-assisted dispersive liquid-liquid microextraction (UDSA-DLLME)" and "water with low concentration of surfactant in dispersed solvent-assisted emulsion dispersive liquid-liquid microextraction (WLSEME)" coupled with gas chromatography-mass spectrometry (GC-MS) have been developed for the analysis of 11 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. For UDSA-DLLME, an up-and-down shaker-assisted emulsification was employed. Extraction was complete in 3min. Only 14 μL of 1-heptanol was required, without a dispersive solvent. Under the optimum conditions, the linear range was 0.08-100 µg L(-1), and the LODs were in the range 0.022-0.060 µg L(-1). The enrichment factors (EFs) ranged from 392 to 766. Relative recoveries were between 84% and 113% for river, lake, and field water. In WLSEME, 9 μL of 1-nonanol as extraction solvent and 240 μL of 1 mg L(-1) Triton X-100 as surfactant were mixed in a microsyringe to form a cloudy emulsified solution, which was then injected into the samples. Compared with other surfactant-assisted emulsion methods, WLSEME uses much less surfactant. The linear range was 0.08-100 µg L(-1), and the LODs were 0.022-0.13 µg L(-1). The EFs ranged from 388 to 649. The relative recoveries were 86-114% for all three water specimens.

  1. Analysis of trace levels of sulfonamide and tetracycline antimicrobials in groundwater and surface water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lindsey, M.E.; Meyer, M.; Thurman, E.M.

    2001-01-01

    A method has been developed for the trace analysis of two classes of antimicrobials consisting of six sulfonamides (SAs) and five tetracyclines (TCs), which commonly are used for veterinary purposes and agricultural feed additives and are suspected to leach into ground and surface water. The method used solid-phase extraction and liquid chromatography/mass spectrometry (LC/MS) with positive ion electrospray. The unique combination of a metal chelation agent (Na2EDTA) with a macroporous copolymer resulted in quantitative recoveries by solid-phase extraction (mean recovery, 98 ?? 12%) at submicrogram-per-liter concentrations. An ammonium formate/formic acid buffer with a methanol/water gradient was used to separate the antimicrobials and to optimize the signal intensity. Mass spectral fragmentation and ionization characteristics were determined for each class of compounds for unequivocal identification. For all SAs, a characteristic m/z 156 ion representing the sulfanilyl fragment was identified. TCs exhibited neutral losses of 17 amu resulting from the loss of ammonia and 35 amu from the subsequent loss of water. Unusual matrix effects were seen only for TCs in this first survey of groundwater and surface water samples from sites around the United States, requiring that TCs be quantitated using the method of standard additions.

  2. Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Oh, Min-Seok; Lee, Seon-Hwa; Moon, Myeong Hee; Lee, Dong Soo; Park, Hyun-Mee

    2014-01-01

    A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standard deviations (RSDs) of 0.92-10.6% and spiked sample recoveries of 80.6-97.8% were obtained. Limits of detection for PAHs were in the range of 0.15-0.77 µg/kg and those for phthalates were in the range of 4.6-10.0 µg/kg. The calibration curves exhibited good linearities with regression coefficients of R(2) ≥ 0.99. Twelve edible oils were examined to evaluate the efficiency of this method. Among the 12 analytes, dibutyl phthalates (DBP), diethylhexyl phthalates (DEHP), diethylhexyl adipate (DEHA), benzo[a]anthracene (B[a]A), chrysene (Chry) and benzo[b]fluoranthene (B[b]F) were detected in the range of 1.17-806 µg/kg.

  3. Recombinant factor C (rFC) assay and gas chromatography/mass spectrometry (GC/MS) analysis of endotoxin variability in four agricultural dusts.

    Science.gov (United States)

    Saito, Rena; Cranmer, Brian K; Tessari, John D; Larsson, Lennart; Mehaffy, John M; Keefe, Thomas J; Reynolds, Stephen J

    2009-10-01

    Endotoxin exposure is a significant concern in agricultural environments due to relatively high exposure levels. The goals of this study were to determine patterns of 3-hydroxy fatty acid (3-OHFA) distribution in dusts from four types of agricultural environments (dairy, cattle feedlot, grain elevator, and corn farm) and to evaluate correlations between the results of gas chromatography/mass spectrometry (GC/MS) analysis (total endotoxin) and biological recombinant factor C (rFC) assay (free bioactive endotoxin). An existing GC/MS-MS method (for house dust) was modified to reduce sample handling and optimized for small amount (rFC assay and the modified GC/EI-MS results was feedlot (0.72) > dairy (0.53) > corn farm (0.33) > grain elevator (0.11). In livestock environments, both odd- and even-numbered carbon chain length 3-OHFAs correlated with rFC assay response. The GC/EI-MS method should be especially useful for identification of specific 3-OHFAs for endotoxins from various agricultural environments and may provide useful information for evaluating the relationship between bacterial exposure and respiratory disease among agricultural workers.

  4. Analysis of linear alkylbenzene sulfonate homologues in environmental water samples by mixed admicelle-based extraction and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Lunar, Loreto; Rubio, Soledad; Pérez-Bendito, Dolores

    2006-07-01

    Hemimicelles and admicelles of cetyltrimethylammonium bromide (CTAB) and cetylpyridinium chloride (CPC), adsorbed onto silica, were tested as sorbents for the solid phase extraction (SPE) of linear alkylbenzene sulfonate (LAS) homologues from environmental water samples. LASs were quantitatively retained on both surfactants due to high hydrophobic and ionic interactions, which led to the formation of analyte-extractant mixed aggregates. Parameters affecting the SPE of LASs were optimised. Recoveries of analytes from wastewater influent and effluent and river water samples ranged between 86 and 110%. Combination of SPE with liquid chromatography/mass spectrometry provided detection limits for the different LAS homologues of about 4 ng L(-1). The precision of the method, expressed as relative standard deviation, ranged from 5 to 9%. The method was applied to the analysis of LASs in wastewater and river samples using sample volumes between 10 and 25 mL. The LAS concentrations found ranged from 9 to 503 microg L(-1). No cleaning step was required to get accurate results.

  5. Analysis of cytochrome P450 metabolites of arachidonic acid by stable isotope probe labeling coupled with ultra high-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Zhu, Quan-Fei; Hao, Yan-Hong; Liu, Ming-Zhou; Yue, Jiang; Ni, Jian; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-09-04

    Cytochrome P450 metabolites of arachidonic acid (AA) belong to eicosanoids and are potent lipid mediators of inflammation. It is well-known that eicosanoids play an important role in numerous pathophysiological processes. Therefore, quantitative analysis of cytochrome P450 metabolites of AA, including hydroxyeicosatetraenoic acids (HETEs), epoxyeicosatreinoic acids (EETs), and dihydroxyeicosatrienoic acids (DHETs) can provide crucial information to uncover underlying mechanisms of cytochrome P450 metabolites of AA related diseases. Herein, we developed a highly sensitive method to identify and quantify HETEs, EETs, and DHETs in lipid extracts of biological samples based on stable isotope probe labeling coupled with ultra high-performance liquid chromatography/mass spectrometry. To this end, a pair of stable isotope probes, 2-dimethylaminoethylamine (DMED) and d4-2-dimethylaminoethylamine (d4-DMED), were utilized to facilely label eicosanoids. The heavy labeled eicosanoid standards were prepared and used as internal standards for quantification to minimize the matrix and ion suppression effects in mass spectrometry analysis. In addition, the detection sensitivities of DMED labeled eicosanoids improved by 3-104 folds in standard solution and 5-138 folds in serum matrix compared with unlabeled analytes. Moreover, a good separation of eicosanoids isomers was achieved upon DMED labeling. The established method provided substantial sensitivity (limit of quantification at sub-picogram), high specificity, and broad linear dynamics range (3 orders of magnitude). We further quantified cytochrome P450 metabolites of AA in rat liver, heart, brain tissues and human serum using the developed method. The results showed that 19 eicosanoids could be distinctly detected and the contents of 11-, 15-, 16-, 20-HETE, 5,6-EET, and 14,15-EET in type 2 diabetes mellitus patients and 5-, 11-, 12-, 15-, 16-, 20-HETE, 8,9-EET, and 5,6-DHET in myeloid leukemia patients had significant changes

  6. Ion chromatography-mass spectrometry: a review of recent technologies and applications in forensic and environmental explosives analysis.

    Science.gov (United States)

    Barron, Leon; Gilchrist, Elizabeth

    2014-01-01

    The development and application of ion chromatography (IC) coupled to mass spectrometry (MS) is discussed herein for the quantitative determination of low-order explosives-related ionic species in environmental and forensic sample types. Issues relating to environmental explosives contamination and the need for more confirmatory IC-MS based applications in forensic science are examined. In particular, the compatibility of a range of IC separation modes with MS detection is summarised along with the analytical challenges that have been overcome to facilitate determinations at the ng-μg L(-1) level. Observed trends in coupling IC to inductively coupled plasma and electrospray ionisation mass spectrometry form a particular focus. This review also includes a discussion of the relative performance of reported IC-MS methods in comparison to orthogonal ion separation-based, spectrometric and spectroscopic approaches to confirmatory detection of low-order explosives. Finally, some promising areas for future research are highlighted and discussed with respect to potential IC-MS applications.

  7. Extraction of essential oil from shaddock peel and analysis of its components by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Essential oil, with more than thirty kinds of compounds separated and identified by gas chromatographymass spectrometry, was extracted from Shatian shaddock peel and Sweet shaddock peel by squeeze-steam distillation and direct steam distillation method. Among their composition, the main components are terpene compounds, which account for 93. 926% (mass fraction, the same below) and 85. 843% of essential oils extracted from Shatian shaddock peel and Sweet shaddock peel, respectively. Although nootkatone is the major contributor of shaddock characteristic scent, and its contents are 1. 069 % and 1. 749 % of essential oils from Sweet shaddock peel and Shatian shaddock peel, respectively. The results show that squeeze-steam distillation gives higher yield and good quality of essential oil and the compositions of essential oils from two kinds of shaddock peels are different, but the main contributors of the shaddock scent are the same.

  8. Volatile Profiles of Emissions from Different Activities Analyzed Using Canister Samplers and Gas Chromatography-Mass Spectrometry (GC/MS) Analysis: A Case Study

    Science.gov (United States)

    Orecchio, Santino; Fiore, Michele; Barreca, Salvatore; Vara, Gabriele

    2017-01-01

    The objective of present study was to identify volatile organic compounds (VOCs) emitted from several sources (fuels, traffic, landfills, coffee roasting, a street-food laboratory, building work, indoor use of incense and candles, a dental laboratory, etc.) located in Palermo (Italy) by using canister autosamplers and gas chromatography-mass spectrometry (GC-MS) technique. In this study, 181 VOCs were monitored. In the atmosphere of Palermo city, propane, butane, isopentane, methyl pentane, hexane, benzene, toluene, meta- and para-xylene, 1,2,4 trimethyl benzene, 1,3,5 trimethyl benzene, ethylbenzene, 4 ethyl toluene and heptane were identified and quantified in all sampling sites. PMID:28212294

  9. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; Smalling, Kelly L.; Kuivila, Kathryn M.

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  10. [Analysis of the components of floral scent in Glochidion puberum using gas chromatography-mass spectrometry with dynamic headspace adsorption].

    Science.gov (United States)

    Huang, Daihong; Zhang, Zhenguo; Chen, Guoping; Li, Houhun; Shi, Fuchen

    2015-03-01

    The floral scent plays the important key role in maintaining the obligate pollination mutualism between Glochidion plants and Epicephala moths. In the study, the dynamic headspace adsorption technique was employed to collect the floral scent emitted by Glochidion puberum, gas chromatography coupled with mass spectrometry (GC-MS) was used for the detection and identification of volatile chemical components in headspace samples of flowers from G. puberum. The peak area normalization was used to determine the relative contents of each odour component. The results showed that 45 compounds mainly consisting of monoterpenes and sesquiterpenes were isolated from the floral scent produced by G. puberum. Especially, both linalool (38.06%) and β-elemene (23.84%) were considered as the major scent components of G. puberum. It was speculated that linalool and β-elemene may be the two potential compounds attracting female Epicephala moths. The study provided the basic data for further electroantennographic detection and bioassays to identify the compounds having the actual physiological activity to female Epicephala moths.

  11. Estimation of brassylic acid by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed J. Nasrullah, Erica N. Pfarr, Pooja Thapliyal, Nicholas S. Dusek, Kristofer L. Schiele, Christy Gallagher-Lein, and James A. Bahr

    2010-10-29

    The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.

  12. [Analysis of fatty acids in Gmnocypris przewalskii oil by gas chromatography/mass spectrometry with base-catalyzed transesterification].

    Science.gov (United States)

    Bo, Haibo; Wang, Xia; Zhai, Zongde; Li, Yongmin; Chen, Liren

    2006-03-01

    The composition of fatty acids (FA) in Gymnocypris przewalskii oil was identified and quantified by gas chromatography (GC)/electron impact (EI) mass spectrometry (MS). A base-catalyzed transesterification method was used to convert fatty acids to methyl esters. The lipids were extracted using petroleum ether and the total lipids in dried meat and skin of Gymnocypris przewalskii were about 25%. Forty-seven fatty acids were identified in the current study. Main types of fatty acids found in the oils were normal saturated, mono-branched, multi-branched, cyclopropane, furanoid, normal monounsaturated and polyunsaturated fatty acids. Saturated fatty acids were approximately 25. 7% of the total, and the main components were C(14:0) (3.4%), C(16:0) (19.4%) and C(18:0) (1.1%). Unsaturated fatty acids were totally 73.6%, and the major components of monounsaturated fatty acids were C(16:1 (9)) (19.8%), C(18:1) (9)) (18. 6%) and C(18:1 (11)) (7.3%); polyunsaturated fatty acids were mainly composed of C(18:2 (9,12)) (4.8%), C(18:3 (9, 12, 15)) (3.1%), C(20:4 (5, 8, 1, 14)) (1.2%), C(20:5 (5, 8, 11, 14, 17)) (EPA, 9.4%) and C(22:6 (4, 7, 10, 13, 16, 19)) (DHA, 6.7%). Especially, furyl-, cyclopropane- and several odd and branched chain fatty acids were found in Gymnocypris przewalskii oil. It is thus an important dietary resource of functional fatty acids.

  13. Improved detection of multiple environmental antibiotics through an optimized sample extraction strategy in liquid chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi

    2015-12-01

    A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.

  14. Dispersive micro solid-phase extraction for the rapid analysis of synthetic polycyclic musks using thermal desorption gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chung, Wu-Hsun; Tzing, Shin-Hwa; Ding, Wang-Hsien

    2013-09-13

    A simple and solvent-free method for the rapid analysis of five synthetic polycyclic musks in water samples is described. The method involves the use of dispersive micro solid-phase extraction (D-μ-SPE) coupled with direct thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) operating in the selected-ion-storage (SIS) mode. The parameters affecting the extraction efficiency of the target analytes from water sample and the thermal desorption conditions in the GC injection-port were optimized using a central composite design method. The optimal extraction conditions involved immersing 3.2mg of a typical octadecyl (C18) bonded silica adsorbent (i.e., ENVI-18) in a 10mL water sample. After extraction by vigorously shaking for 1.0min, the adsorbents were collected and dried on a filter. The adsorbents were transferred to a micro-vial, which was directly inserted into GC temperature-programmed injector, and the extracted target analytes were then thermally desorbed in the GC injection-port at 337°C for 3.8min. The limits of quantitation (LOQs) were determined to be 1.2-3.0ng/L. Precision, as indicated by relative standard deviations (RSDs), was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 and 90%. A preliminary analysis of the river water samples revealed that galaxolide (HHCB) and tonalide (AHTN) were the two most common synthetic polycyclic musks present. Using a standard addition method, their concentrations were determined to in the range from 11 to 140ng/L.

  15. Metabonomics analysis of urine and plasma from rats given long-term and low-dose dimethoate by ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Feng, Zhijing; Sun, Xiaowei; Yang, Jindan; Hao, Dongfang; Du, Longfei; Wang, Hong; Xu, Wei; Zhao, Xiujuan; Sun, Changhao

    2012-09-30

    This study assessed the effects of long-term, low-dose dimethoate administration to rats by ultra-performance liquid chromatography-mass spectrometry (UPLC-MS). Dimethoate (0.04, 0.12, and 0.36 mg/kg body weight/day) was administered daily to male Wistar rats through their drinking water for 24 weeks. Significant changes in serum clinical chemistry were observed in the middle- and high-dose groups. UPLC-MS revealed evident separate clustering among the different dose groups using global metabolic profiling by supervised partial least squares-discriminant analysis. Metabonomic analysis showed alterations in a number of metabolites (12 from urine and 13 from plasma), such as L-tyrosine, dimethylthiophosphate (DMTP), dimethyldithiophosphate (DMDTP), citric acid, uric acid, suberic acid, glycylproline, allantoin, isovalerylglutamic acid and kinds of lipids. The results suggest that long-term, low-dose exposure to dimethoate can cause disturbances in liver function, antioxidant and nervous systems, as well as the metabolisms of lipids, glucose, fatty acids, amino acids, and collagen in rats. DMTP and DMDTP, which had the most significant changes among all other studied biomarkers, were considered as early, sensitive biomarkers of exposure to dimethoate. The other aforementioned proposed toxicity biomarkers in metabonomic analysis may be useful in the risk assessment of the toxic effects of dimethoate. Metabonomics as a systems toxicology approach was able to provide comprehensive information on the dynamic process of dimethoate induced toxicity. In addition, the results indicate that metabonomic approach could detect systemic toxic effects at an earlier stage compared to clinical chemistry. The combination of metabonomics and clinical chemistry made the toxicity of dimethoate on rats more comprehensive.

  16. Analysis of trace contamination of phthalate esters in ultrapure water using a modified solid-phase extraction procedure and automated thermal desorption-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Liu, Hsu-Chuan; Den, Walter; Chan, Shu-Fei; Kin, Kuan Tzu

    2008-04-25

    The present study was aimed to develop a procedure modified from the conventional solid-phase extraction (SPE) method for the analysis of trace concentration of phthalate esters in industrial ultrapure water (UPW). The proposed procedure allows UPW sample to be drawn through a sampling tube containing hydrophobic sorbent (Tenax TA) to concentrate the aqueous phthalate esters. The solid trap was then demoisturized by two-stage gas drying before subjecting to thermal desorption and analysis by gas chromatography-mass spectrometry. This process removes the solvent extraction procedure necessary for the conventional SPE method, and permits automation of the analytical procedure for high-volume analyses. Several important parameters, including desorption temperature and duration, packing quantity and demoisturizing procedure, were optimized in this study based on the analytical sensitivity for a standard mixture containing five different phthalate esters. The method detection limits for the five phthalate esters were between 36 ng l(-1) and 95 ng l(-1) and recovery rates between 15% and 101%. Dioctyl phthalate (DOP) was not recovered adequately because the compound was both poorly adsorbed and desorbed on and off Tenax TA sorbents. Furthermore, analyses of material leaching from poly(vinyl chloride) (PVC) tubes as well as the actual water samples showed that di-n-butyl phthalate (DBP) and di(2-ethylhexyl) phthalate (DEHP) were the common contaminants detected from PVC contaminated UPW and the actual UPW, as well as in tap water. The reduction of DEHP in the production processes of actual UPW was clearly observed, however a DEHP concentration of 0.20 microg l(-1) at the point of use was still being quantified, suggesting that the contamination of phthalate esters could present a barrier to the future cleanliness requirement of UPW. The work demonstrated that the proposed modified SPE procedure provided an effective method for rapid analysis and contamination

  17. Rapid enzymatic hydrolysis of masked deoxynivalenol and zearalenone prior to liquid chromatography mass spectrometry or immuniassay analysis

    NARCIS (Netherlands)

    Nielen, M.W.F.; Weijers, C.A.G.M.; Peters, J.; Weignerová, L.; Zuilhof, H.; Franssen, M.C.R.

    2014-01-01

    Recently it has been shown that conjugates (‘masked mycotoxins’) may contribute to the total daily intake of hazardous mycotoxins. Therefore, there is an urgent need for rapid analysis methods that assess the level of both free and masked mycotoxins in food and feed. However, the analysis of masked

  18. Separation of Caffeine from Beverages and Analysis Using Thin-Layer Chromatography and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Torres y Torres, Janelle L.; Hiley, Shauna L.; Lorimor, Steven P.; Rhoad, Jonathan S.; Caldwell, Benjamin D.; Zweerink, Gerald L.; Ducey, Michael

    2015-01-01

    The Characterization and Analysis of a Product (CAP) project is used to introduce first-semester general chemistry students to chemical instrumentation through the analysis of caffeine-containing beverage products. Some examples of these products have included coffee, tea, and energy drinks. Students perform at least three instrumental experiments…

  19. Direct Analysis of Leucine and Its Metabolites β-Hydroxy-β-methylbutyric Acid, α-Ketoisocaproic Acid, and α-Hydroxyisocaproic Acid in Human Breast Milk by Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ehling, Stefan; Reddy, Todime M

    2015-09-02

    A direct, quantitative, and confirmatory method based on stable isotope dilution liquid chromatography-mass spectrometry was developed and validated for the analysis of leucine and metabolites β-hydroxy-β-methylbutyric acid (HMB), α-ketoisocaproic acid (KIC), and α-hydroxyisocaproic acid (HICA) in human breast milk. Chromatographic resolution was achieved between isobaric leucine and isoleucine. Accuracy and intermediate precision were 89-117% and breast milk composition and its effect on protein turnover in developing infants.

  20. Measurement of abscisic acid and gibberellins by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Okamoto, Masanori; Hanada, Atsushi; Kamiya, Yuji; Yamaguchi, Shinjiro; Nambara, Eiji

    2009-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based analysis is an accurate and sensitive method to quantify plant hormones. This method is commonly used for analysis of low-molecular-weight compounds, such as abscisic acid (ABA), gibberellins (GAs), auxins, and brassinosteroids. Procedures are composed of four major steps: extraction, fractionation, derivatization, and detection. Here, we describe a protocol for quantification of ABA and GAs.

  1. Analysis of yohimbine alkaloid from Pausinystalia yohimbe by non-aqueous capillary electrophoresis and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Qinhua; Li, Peng; Zhang, Zhuo; Li, Kaijun; Liu, Jia; Li, Qiang

    2008-07-01

    In the present work, the qualitative and quantitative analysis of Pausinystalia yohimbe-type alkaloids in the barks of Rubiaceae species is presented using different analytical approaches. Extracts of P. yohimbe were first examined by GC-MS and the major alkaloids were identified. The quantitation of yohimbine was then accomplished by non-aqueous CE (NACE) with diode array detection. This approach was selected in order to use a running buffer fully compatible with samples in organic solvent. In particular, a mixture of methanol containing ammonium acetate (20 mM) and glacial acetic acid was used as a BGE. The same analytical sample was subjected to GC-MS and NACE analysis; the different selectivity displayed by these techniques allowed different separation profiles that can be useful in phytochemical characterization of the extracts. The linear calibration ranges were all 10-1000 microg/mL for yohimbine by GC-MS and NACE analysis. The recovery of yohimbine was 91.2-94.0% with RSD 1.4-4.3%. The LOD for yohimbine were 0.6 microg/mL by GC-MS and 1.0 microg/mL by NACE, respectively. The GC-MS and NACE methods were successfully validated and applied to the quantitation of yohimbine.

  2. Analysis of neutral nitromusks in incenses by capillary electrophoresis in organic solvents and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gotti, Roberto; Fiori, Jessica; Mancini, Francesca; Cavrini, Vanni

    2005-09-01

    Nitromusks used as fragrances in a variety of personal-care products, cleansers, and domestic deodorants, including incense sticks, are neutral nitro aromatic compounds; some of these have been reported as photosensitizers. In this work, their analysis was performed by capillary electrophoresis (CE) in a methanol-based background electrolyte (BGE). In particular, a 10 mM solution of citric acid in methanol was used; under these conditions the strong suppression of the electroosmotic flow favored the use of negatively charged surfactants as additives for the anodic migration of the studied analytes. To this end, sodium taurodeoxycholate (TDC) was supplemented at high concentration (190 mM) to the organic background electrolyte (BGE), showing strong indication of the ability to give micelle-like aggregates. Since nitromusks are characterized by the presence of a nitroaromatic ring with low charge density, their association with TDC aggregates can be ascribed to donor-acceptor interactions. Separation of musk xylene, musk ketone, and the banned musk moskene and musk ambrette was obtained under full nonaqueous BGE; the addition of relatively small water percentages (15% v/v) was found to be useful in improving the separation of pairs of adjacent peaks. Under optimized conditions (190 mM sodium TDC in methanol-water, 85-15 v/v containing citric acid 10 mM) the system was applied to the analysis of nitromusks in incense sticks extracted with methanol. The results were compared with those obtained by the analysis of the same samples using gas chromatography with mass detector. The expected different selectivity of separation obtained using the two techniques can be useful in the unambiguous determination of the analytes; furthermore, a substantial accord of the preliminary quantitative results achieved with the two methods was assumed as the confirmation of the potential reliability of CE performed with high percentage of organic solvent.

  3. Direct analysis of volatile fatty acids in marine sediment porewater by two-dimensional ion chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Glombitza, Clemens; Pedersen, Jeanette; Røy, Hans

    2014-01-01

    Volatile fatty acids (VFAs) are key intermediates in the microbial food web. However, the analysis of low concentrations of VFAs in marine porewater is hampered by interference from high concentrations of inorganic ions. Published methods often use sample pretreatment, including distillation...... or derivatization, to overcome this problem. This is not only labor intensive but also increases the risk of contamination. We have developed an analytical procedure that enables the direct quantification of several VFAs (formate, acetate, propionate, butyrate, valerate, pyruvate, and lactate) in marine porewater...

  4. Improved high sensitivity analysis of polyphenols and their metabolites by nano-liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wilson, Landon; Arabshahi, Ali; Simons, Brigitte; Prasain, Jeevan K; Barnes, Stephen

    2014-10-01

    This study was conducted to assess the value of a high resolution, high mass accuracy time-of-flight analyzer in combination with nanoliquid chromatography for the analysis of polyphenols and their metabolites. The goal was to create a method that utilizes small volumes of biological fluids and provides a significant improvement in sensitivity compared with existing methods. Accordingly, nanoLC-MS and nanoLC-pseudo-multiple reaction monitoring (MRM) methods were developed that had a lower limit of quantification of 0.5 nM for several polyphenols and were linear over 2-3 orders of magnitude (R(2)>0.999). Using urine samples, the ability to observe and quantify polyphenols in such a complex biological fluid depended on much narrower mass windows (0.050 amu or less) on a TOF analyzer than those used on a quadrupole analyzer (0.7 amu). Although a greater selectivity was possible with the low mass resolution of a triple quadrupole instrument using the MRM approach, for the daidzein metabolite O-DMA, a chromatographically resolvable second peak could only be substantially reduced by using a 0.01 amu mass window. The advantage of a TOF analyzer for product ion data is that the whole MSMS spectrum is collected at high mass accuracy and MRM experiments are conducted in silico after the analysis.

  5. Determination of acidic pharmaceuticals and potential endocrine disrupting compounds in wastewaters and spring waters by selective elution and analysis by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gibson, Richard; Becerril-Bravo, Elías; Silva-Castro, Vanessa; Jiménez, Blanca

    2007-10-26

    Although the trend in development of analytical methods for emerging contaminants is towards reduced sample preparation and increased detector selectivity, there are still benefits from removal of matrix material during sample preparation. This paper describes a simple method for acidic pharmaceuticals and a range of potential endocrine disrupting compounds in untreated wastewaters and spring waters. It is based on separation of the two classes during elution from the extraction cartridge with final analysis by gas chromatography-mass spectrometry. 3,4-D was used as the recovery standard for the acids while 4-n-nonylphenol and [2H4]estrone were used for the endocrine disrupters; mean recoveries varied between 89% and 111%. The method was also extensively validated by fortification with the target compounds. Recoveries of acids were from 68% to 97% with relative standard deviations generally less than 10% and recoveries of endocrine disrupters were 68-109% with relative standard deviations less than 20%. Detection limits varied from 0.005 to 1 ng/L in spring water, and from 0.5 to 100 ng/L in untreated wastewater. Concentrations of the analytes in the wastewater ranged from 0.018 to 22.4 microg/L. Values were comparable to reported data, although concentrations were generally relatively high, probably because of a lack of treatment. Triclosan, phthalates, estrone, 17beta-estradiol, ibuprofen, and naproxen were present in the spring water from aquifers recharged indirectly with this wastewater after its use for irrigation; concentrations ranged from 0.01 to 25.0 ng/L. The much lower concentrations compared to wastewater indicate effective removal processes on passage through the soil and subsoil.

  6. Imidacloprid Extraction from Citrus Leaves and Analysis by Liquid Chromatography-Mass Spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Leiva, Jorge A; Nkedi-Kizza, Peter; Borejsza-Wysocki, Wlodzimierz S; Bauder, Victor S; Morgan, Kelly T

    2016-05-01

    A procedure was developed to extract Imidacloprid (IMD) from newly-flushed and fully-expanded citrus leaves. The extraction was conducted in a bullet blender, using a small sample mass (0.5 g of fresh tissue), stainless-steel beads (24 g), and methanol as extractant (10 mL). The extracts did not require further clean-up before analysis by HPLC-MS/MS. The method was validated with control samples from IMD-untreated Hamlin orange trees. The method limit of detection and limit of quantitation were 0.04 and 0.12 μg g(-1), respectively. IMD recoveries from fortified leaf tissue were between 92 % and 102 %, with relative standard deviations of leaves from Hamlin orange trees treated with IMD. The treated trees showed maximum concentrations of 10.8 and 21.8 µg g(-1), observed at 20 days after applying two soil-drenching rates (0.51 and 1.02 kg IMD ha(-1)), respectively. This extraction technique will generate useful data on IMD plant uptake, foliar concentration, and correlations with Asian citrus psyllid (ACP) mortality or control. The method could be used to generate baseline data to improve IMD soil-drenching applications as the main management practice to control the ACP.

  7. Lipidome and metabolome analysis of fresh tobacco leaves in different geographical regions using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Lili; Lu, Xin; Zhao, Jieyu; Zhang, Junjie; Zhao, Yanni; Zhao, Chunxia; Xu, Guowang

    2015-07-01

    The combination of the lipidome and the metabolome can provide much more information in plant metabolomics studies. A method for the simultaneous extraction of the lipidome and the metabolome of fresh tobacco leaves was developed. Method validation was performed on the basis of the optimal ratio of methanol to methyl tert-butyl ether to water (37:45:68) from the design of experiments. Good repeatability was obtained. We found that 92.2% and 91.6% of the peaks for the lipidome and the metabolome were within a relative standard deviation of 20%, accounting for 94.6% and 94.6% of the total abundance, respectively. The intraday and interday precisions were also satisfactory. A total of 230 metabolites, including 129 lipids, were identified. Significant differences were found in lipidomic and metabolomic profiles of fresh tobacco leaves in different geographical regions. Highly unsaturated galactolipids, phosphatidylethanolamines, predominant phosphatidylcholines, most of the polyphenols, amino acids, and polyamines had a higher content in Yunnan province, and low-unsaturation-degree galactolipids, triacylglycerols, glucosylceramides with trihydroxy long-chain bases, acylated sterol glucosides, and some organic acids were more abundant in Henan province. Correlation analysis between differential metabolites and climatic factors indicated the vital importance of temperature. The fatty acid unsaturation degree of galactolipids could be influenced by temperature. Accumulation of polyphenols and decreases in the ratios of stigmasterols to sitosterols and glucosylstigmasterols to glucosylsitosterols were also correlated with lower temperature in Yunnan province. Furthermore, lipids were more sensitive to climatic variations than other metabolites.

  8. Field-Free Atmospheric Pressure Photoionization - Liquid Chromatography - Mass Spectrometry for the Analysis of Steroids within Complex Biological Matrices.

    Science.gov (United States)

    McCulloch, Ross David; Robb, Damon B

    2017-03-06

    A comparison study is presented in which the relative performance of a new orthogonal geometry field-free atmospheric pressure photoionization (FF-APPI) source was evaluated against both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) for the analysis of a small panel of clinically relevant steroids, spiked within various complex biological matrices. Critical performance factors like sensitivity and susceptibility to matrix effects were assessed using a simple, isocratic, high throughput LC-MS workflow. FF-APPI was found to provide the best performance in terms of both sensitivity and detection limit for all of the steroids included in the survey. Order-of-magnitude sensitivity advantages were realized for some low polarity analytes including both estradiol and estrone. A robust linear regression, post extraction addition method was used to evaluate the relative impact of matrix effects upon each ionization method using protein precipitated human serum, plasma and Surine (simulated urine) as standard clinical matrices. Under conditions optimized for sensitivity, both the field-free APPI and APCI sources were found to provide similarly high resistance to matrix suppression effects, while ESI performance was impacted the most dramatically. For the prototype FF-APPI source, a strong relationship was established between optimizable source parameters and the degree of ion suppression observed. Through careful optimization of vaporization temperature and nebulizer gas flow rates it was possible to significantly reduce or even eliminate the impact of matrix effects, even for high throughput LC-MS methods.

  9. Analysis of Mammalian Cell Proliferation and Macromolecule Synthesis Using Deuterated Water and Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Victoria C. Foletta

    2016-10-01

    Full Text Available Deuterated water (2H2O, a stable isotopic tracer, provides a convenient and reliable way to label multiple cellular biomass components (macromolecules, thus permitting the calculation of their synthesis rates. Here, we have combined 2H2O labelling, GC-MS analysis and a novel cell fractionation method to extract multiple biomass components (DNA, protein and lipids from the one biological sample, thus permitting the simultaneous measurement of DNA (cell proliferation, protein and lipid synthesis rates. We have used this approach to characterize the turnover rates and metabolism of a panel of mammalian cells in vitro (muscle C2C12 and colon cancer cell lines. Our data show that in actively-proliferating cells, biomass synthesis rates are strongly linked to the rate of cell division. Furthermore, in both proliferating and non-proliferating cells, it is the lipid pool that undergoes the most rapid turnover when compared to DNA and protein. Finally, our data in human colon cancer cell lines reveal a marked heterogeneity in the reliance on the de novo lipogenic pathway, with the cells being dependent on both ‘self-made’ and exogenously-derived fatty acid.

  10. Analysis of major congeners of polybromobiphenyls and polybromodiphenyl ethers in office dust using high resolution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kefeni, Kebede K; Okonkwo, Jonathan O

    2012-05-01

    The study focused on analysis of polybromobiphenyls (PBBs) and polybromodiphenyl ethers (PBDEs) congeners in office dust obtained in Pretoria, South Africa. Of the 32 congeners considered for identification, (BB-1, 2, 4, 10, 15, 26, 29, 30, 31, 38, 49, 80, 103, 153, 155, 209 and BDE-3, 15, 17, 28, 47, 66, 77, 85, 99, 100, 126, 138, 153, 154, 183, 209) only BB-2, 4, 30, 153, 209 and BDE-47, 66, 85, 99, 153 and 209 congeners were detected. The sum of PBBs concentration detected in office dust ranged from

  11. Optimization of the derivatization protocol of pentacyclic triterpenes prior to their gas chromatography-mass spectrometry analysis in plant extracts.

    Science.gov (United States)

    Jemmali, Zaineb; Chartier, Agnes; Dufresne, Christelle; Elfakir, Claire

    2016-01-15

    This paper focuses on the application of a two-level full factorial design to optimize the key derivatization step before the GC-FID and GC-MS analysis of pentacyclic triterpenes. The derivatization reaction was screened for influential factors and statistically significant parameters with a p value less than 0.05. A multi-response optimization based on a desirability function was then applied, while simultaneously considering overall detection enhancement of compounds. Results showed that derivatization using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and trimethylchlorosilane (TMCS) in pyridine (22:13:65v/v/v) for 2h at 30°C was the most efficient method of derivatizing all the hydroxyl and carboxylic acid groups contained in the triterpene structures. The validity of the method was demonstrated using GC-MS analyzes of a mixture containing eleven standards (β-amyrin, α-amyrin, lupeol, erythrodiol, uvaol, betulin, oleanolic acid, betulinic acid, ursolic acid, maslinic acid and corosolic acid). These compounds are representative of different classes of terpene compounds bearing different functional groups such as alcohols, diols, and carboxylic acids. The derivatization procedure was then tested on four plant extracts: apple pomace, salvia sclarea (dried leaves and flowers), sea buckthorn (Hyppophae rhammnoides L.) berries, and B. serrata resin. The identification of triterpenes was based on the comparison of their retention time and mass spectra to those of standards. The presence of compounds already identified in the literature was confirmed and new ones such as maslinic and corosolic acids were identified in apples, sea buckthorn and salvia sclarea.

  12. Comparison of gravimetry and hydrolysis/derivatization/gas chromatography-mass spectrometry for quantitative analysis of fat from standard reference infant formula powder using supercritical fluid extraction.

    Science.gov (United States)

    Ashraf-Khorassani, M; Ude, M; Doane-Weideman, T; Tomczak, J; Taylor, L T

    2002-03-27

    This paper describes a comparative study of the gravimetric versus hydrolysis/derivatization/gas chromatography-mass spectrometry determination of fat in infant formula. Fat was extracted using supercritical carbon dioxide modified with a small amount of ethanol, the extract was weighed, and the total fat was determined gravimetrically. Subsequently, another sample of the supercritical fluid fat extract was hydrolyzed to yield free fatty acids, which were converted to their methyl ester derivatives (FAMEs). Quantification was performed by GC-MS. NIST Standard Reference Material (SRM-1846) was used to validate both fat determination methods. Results showed that the gravimetric average percent fat was 26.86%, whereas the GC-MS method yielded 24.64%. Some peaks were detected in the ion chromatogram from the GC-MS that were identified as nonfatty acids such as aldehydes, which may account for the higher percentage fat measured as weight of extract rather than measured as FAMEs expressed as triglycerides.

  13. Microwave distillation followed by headspace single drop microextraction coupled to gas chromatography-mass spectrometry (GC-MS) for fast analysis of volatile components of Echinophora platyloba DC.

    Science.gov (United States)

    Gholivand, Mohammad Bagher; Abolghasemi, Mir Mahdi; Piryaei, Marzieh; Maassoumi, Sayed Mohammad; Papzan, Abdolhamid

    2013-05-01

    To avoid the traditional and time consuming hydrodistillation, the analyses of volatile components in aerial parts of Echinophora platyloba DC was carried out by a simple microwave distillation followed by headspace single drop microextraction (MD-HS-SDME) coupled to gas chromatography-mass spectrometry (GC-MS). The headspace volatile compounds were collected after irradiation using a single drop of n-heptadecan. The extraction conditions were optimised using the relative peak areas as index. The chemical composition of the MD-HS-SDME extracts was confirmed according to their retention indexes and mass spectra. Fifty-three components were extracted and identified by using the MD-HS-SDME method. E-β-ocimene (53.81%), R-D-decalactone (12.75%), α-pinene (6.43%), n-heptanol (6.27%), β-phellanderne (2.70%) and linalool (1.89%) were the major constituents.

  14. Analysis of chemical warfare agents in organic liquid samples with magnetic dispersive solid phase extraction and gas chromatography mass spectrometry for verification of the chemical weapons convention.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud, Raghavender D; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-05-27

    A simple, sensitive and low temperature sample preparation method is developed for detection and identification of Chemical Warfare Agents (CWAs) and scheduled esters in organic liquid using magnetic dispersive solid phase extraction (MDSPE) followed by gas chromatography-mass spectrometry analysis. The method utilizes Iron oxide@Poly(methacrylic acid-co-ethylene glycol dimethacrylate) resin (Fe2O3@Poly(MAA-co-EGDMA)) as sorbent. Variants of these sorbents were prepared by precipitation polymerization of methacrylic acid-co-ethylene glycol dimethacrylate (MAA-co-EGDMA) onto Fe2O3 nanoparticles. Fe2O3@poly(MAA-co-EGDMA) with 20% MAA showed highest recovery of analytes. Extractions were performed with magnetic microspheres by MDSPE. Parameters affecting the extraction efficiency were studied and optimized. Under the optimized conditions, method showed linearity in the range of 0.1-3.0μgmL(-1) (r(2)=0.9966-0.9987). The repeatability and reproducibility (relative standard deviations (RSDs) %) were in the range of 4.5-7.6% and 3.4-6.2% respectively for organophosphorous esters in dodecane. Limits of detection (S/N=3/1) and limit of quantification (S/N=10/1) were found to be in the range of 0.05-0.1μgmL(-1) and 0.1-0.12μgmL(-1) respectively in SIM mode for selected analytes. The method was successfully validated and applied to the extraction and identification of targeted analytes from three different organic liquids i.e. n-hexane, dodecane and silicon oil. Recoveries ranged from 58.7 to 97.3% and 53.8 to 95.5% at 3μgmL(-1) and 1μgmL(-1) spiking concentrations. Detection of diethyl methylphosphonate (DEMP) and O-Ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) in samples provided by the Organization for Prohibition of Chemical Weapons Proficiency Test (OPCW-PT) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals.

  15. Characterisation of beeswax in works of art by gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry procedures.

    Science.gov (United States)

    Bonaduce, Ilaria; Colombini, Maria Perla

    2004-03-05

    Pyrolysis (Py) with in situ derivatisation with hexamethyldisilazane-gas chroma-break tography-mass spectrometry (GC-MS) and a gas chromatography-mass spectrometry procedure based on microwave-assisted saponification were used to identify the organic components in small sized beeswax samples. With the latter procedure quantitative recoveries can be made and hydrocarbons, alcohols and omega-1-diols in the neutral fraction, and fatty acids and omega-1-hydroxy acids in the acidic fraction can be efficiently separated and detected. Both procedures were used to characterise a wax anatomic sculpture "The Plague" (1691-1694) by Gaetano Zumbo, resulting in the identification of beeswax and a Pinaceae resin. The GC-MS analysis brought to light some essential differences in beeswax composition between the raw material and the old modelled wax thus giving some clear indications about the recipe used by the sculptor.

  16. Analysis of Oxidation Product of Cyclohexane by Gas Chromatography-Mass Spectrometry%环己烷氧化产物的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    陆慧宁; 任三香

    2004-01-01

    The catalyze oxidation products of cyclohexane were analyzed by gas chromatography-mass spectrometry (GC/MS). An unknown main component had been identified by manual solution and chemical reaction as peroxy-cyclohexanol.

  17. 热裂解气相色谱-质谱联用技术在材料检测中的应用%Application of pyrolysis gas chromatography-mass spectrometry technology in material analysis

    Institute of Scientific and Technical Information of China (English)

    董海峰; 刘伟丽; 高峡; 周明强; 胡光辉

    2016-01-01

    Pyrolysis gas chromatography-mass spectrometry (Py-GC-MS) technology is a kind of pyrolysis technology combined with gas chromatography-mass spectrometry. Py-GC-MS is not only suitable for the qualitative detection of conventional polymers, but also suitable for the analysis of refractory and complex of organic matters, especially for the analysis of complex polymer materials. This technology can be used for accurate qualitative analysis of complex samples by changing the pyrolysis conditions of Py-GC-MS and combining with infrared spectroscopy technology and etc. This paper introduced the development process, basic principles, characteristics, pyrolysis unit types and application scopes of Py-GC-MS and its applications in the analysis of trace substances, food packaging materials and unknown materials.%热裂解气相色谱-质谱联用(pyrolysis gas chromatography-mass spectrometry, Py-GC-MS)技术是将热裂解技术与气相色谱-质谱联用技术相结合。Py-GC-MS不仅适用于常规聚合物的定性检测,还适用于分析难溶以及复杂的有机物质,尤其适用于分析复杂高分子物质。通过改变Py-GC-MS的裂解条件以及结合红外光谱等技术可以对复杂样品进行准确的定性分析。本文介绍了 Py-GC-MS 的发展过程、基本原理、特点、裂解装置的类型及其应用范围,并介绍了该技术在微量物质、食品包装材料和未知物分析中的应用。

  18. Advances in Application of Chromatography and Chromatography- Mass Spectrometry in Analysis of Traditional Chinese Medicine%色谱及色谱-质谱联用技术在中药分析中的应用进展

    Institute of Scientific and Technical Information of China (English)

    张晶; 杨海龙; 臧恒昌

    2013-01-01

    The advances in the application of chromatography and chromatography- mass spectrometry in the analysis of traditional Chinese medicine (TCM) are reviewed in this paper. Characteristics, range of application and research status of each method are elaborated, which aim to provide reference for TCM researchers.%  对色谱及其质谱联用技术在中药领域的应用进展做一综述,阐述了各方法的特点、应用范围及研究现状,旨在为中药研究工作者提供参考依据。

  19. Improvement of a headspace solid phase microextraction-gas chromatography/mass spectrometry method for the analysis of wheat bread volatile compounds.

    Science.gov (United States)

    Raffo, Antonio; Carcea, Marina; Castagna, Claudia; Magrì, Andrea

    2015-08-07

    An improved method based on headspace solid phase microextraction combined with gas chromatography-mass spectrometry (HS-SPME/GC-MS) was proposed for the semi-quantitative determination of wheat bread volatile compounds isolated from both whole slice and crust samples. A DVB/CAR/PDMS fibre was used to extract volatiles from the headspace of a bread powdered sample dispersed in a sodium chloride (20%) aqueous solution and kept for 60min at 50°C under controlled stirring. Thirty-nine out of all the extracted volatiles were fully identified, whereas for 95 other volatiles a tentative identification was proposed, to give a complete as possible profile of wheat bread volatile compounds. The use of an array of ten structurally and physicochemically similar internal standards allowed to markedly improve method precision with respect to previous HS-SPME/GC-MS methods for bread volatiles. Good linearity of the method was verified for a selection of volatiles from several chemical groups by calibration with matrix-matched extraction solutions. This simple, rapid, precise and sensitive method could represent a valuable tool to obtain semi-quantitative information when investigating the influence of technological factors on volatiles formation in wheat bread and other bakery products.

  20. Multiclass pesticide analysis in fruit-based baby food: A comparative study of sample preparation techniques previous to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Petrarca, Mateus H; Fernandes, José O; Godoy, Helena T; Cunha, Sara C

    2016-12-01

    With the aim to develop a new gas chromatography-mass spectrometry method to analyze 24 pesticide residues in baby foods at the level imposed by established regulation two simple, rapid and environmental-friendly sample preparation techniques based on QuEChERS (quick, easy, cheap, effective, robust and safe) were compared - QuEChERS with dispersive liquid-liquid microextraction (DLLME) and QuEChERS with dispersive solid-phase extraction (d-SPE). Both sample preparation techniques achieved suitable performance criteria, including selectivity, linearity, acceptable recovery (70-120%) and precision (⩽20%). A higher enrichment factor was observed for DLLME and consequently better limits of detection and quantification were obtained. Nevertheless, d-SPE provided a more effective removal of matrix co-extractives from extracts than DLLME, which contributed to lower matrix effects. Twenty-two commercial fruit-based baby food samples were analyzed by the developed method, being procymidone detected in one sample at a level above the legal limit established by EU.

  1. Trace analysis of chlorophenols in river water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, M.; Ishii, Y.; Okanouchi, N.; Sakui, N.; Ito, R.; Inoue, K.; Nakazawa, H. [Hoshi Univ., Tokyo (Japan). Dept. of Analytical Chemistry, Faculty of Pharmaceutical Sciences; Saito, K. [Saitama Institute of Public Health, Saitama (Japan). Dioxin Research Group

    2004-09-15

    Many analytical methods for the determination of chlorophenols in water samples have been reported including gas chromatography-mass spectrometry (GC-MS). However, GC-MS was initially used for the determination of phenol compounds even though derivatization was required. The derivatization leads to sharper peaks and hence to better separation and higher sensitivity for the phenols. However, the derivatization faces the risk of contamination and hence an overestimation of chlorophenols concentration. In order to overcome these problems, in situ derivatization has been developed, which involves the simple addition of a reagent to a liquid sample. Recently, a new sorptive extraction technique that uses a stir bar coated with polydimethylsiloxane (PDMS) was developed. The technique is known as stir bar sorptive extraction (SBSE). We already reported that determination of 4-tert-octylphenol (OP) and 4-nonylphenol (NP) in river water4 and body fluid samples by using SBSE. In addition, SBSE with in situ derivatization has been successfully used in the determination of bisphenol A (BPA) in human body fluid samples6 and phenolic xenoestrogens in river water samples. The aim of this study is to determine trace amounts of chlorophenols in water samples by SBSE with in situ derivatization, followed by thermal desorption (TD)-GC-MS. The developed method was applied to determination of chlorophenols in river water samples.

  2. Heparin stability by determining unsubstituted amino groups using hydrophilic interaction chromatography mass spectrometry.

    Science.gov (United States)

    Fu, Li; Li, Lingyun; Cai, Chao; Li, Guoyun; Zhang, Fuming; Linhardt, Robert J

    2014-09-15

    The thermal instability of the anticoagulant heparin is associated, in part, with the solvolytic loss of N-sulfo groups. This study describes a new method to assess the increased content of unsubstituted amino groups present in thermally stressed and autoclave-sterilized heparin formulations. N-Acetylation of heparin samples with acetic anhydride-d6 is followed by exhaustive heparinase treatment and disaccharide analysis by hydrophilic interaction chromatography mass spectrometry (HILIC-MS). The introduction of a stable isotopic label provides a sensitive probe for the detection and localization of the lost N-sulfo groups, potentially providing valuable insights into the degradation mechanism and the reasons for anticoagulant potency loss.

  3. Screening of Brazilian fruit aromas using solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Augusto, F; Valente, A L; dos Santos Tada, E; Rivellino, S R

    2000-03-17

    Manual headspace solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) was used for the qualitative analysis of the aromas of four native Brazilian fruits: cupuassu (Theobroma grandiflorum, Spreng.), cajá (Spondias lutea. L.), siriguela (Spondias purpurea, L.) and graviola (Anona reticulata, L). Industrialized pulps of these fruits were used as samples, and extractions with SPME fibers coated with polydimethylsiloxane, polyacrylate, Carbowax and Carboxen were carried out. The analytes identified included several alcohols, esters, carbonyl compounds and terpernoids. The highest amounts extracted, evaluated from the sum of peak areas, were achieved using the Carboxen fiber.

  4. Identification of a flunixin metabolite in camel by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Wasfi, I A; Hadi, A A; Alkatheeri, N A; Barezaiq, I M; ElGhazali, M; Boni, N S; Zorob, O

    1998-05-29

    A flunixin metabolite, a hydroxylated product, has been identified in camel urine and plasma samples using gas chromatography-mass spectrometry (GC-MS) and GC-MS-MS in the electron impact and chemical ionization modes. Its major fragmentation pattern has been verified by GC-MS-MS in daughter ion and parent ion scan modes. The method could detect flunixin and its metabolite in camel urine after a single intravenous dose of 2.2 mg of flunixin/kg body weight for 96 and 48 h, respectively, which increases the reliability of antidoping control analysis.

  5. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  6. The bridge between thin layer chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry: The realization of liquid thin layer chromatography-mass spectrometry (LTLC-MS).

    Science.gov (United States)

    Li, Yafeng; Wang, Jianing; Zhan, Lingpeng; Wleklinski, Michael; Wang, Jiyun; Xiong, Caiqiao; Liu, Huihui; Zhou, Yueming; Nie, Zongxiu

    2016-08-19

    The combination of thin layer chromatography (TLC) and mass spectrometry (MS) has been studied for decades, but for most cases MS detection is done after TLC separation is finished. Here, an online simultaneous TLC-MS analysis system, liquid thin layer chromatography-mass spectrometry (LTLC-MS), is developed which successfully synchronize TLC separation process and MS detection process like GC-MS and HPLC-MS do. And there's no need to use specially designed TLC, just regular TLC plates are enough. LTLC-MS method is composed of a newly developed ambient ionization method, glow discharge-matrix assisted infrared desorption ionization (GD-MAIRDI), and forced-flow TLC (FFTLC) technique, which guarantees the MS detection process does not disturb the TLC separation process throughout the whole analysis. The whole LTLC-MS analysis only need two steps and less than 15min. Mixtures as well as the two main components of a pain relief pills have been successfully analyzed by LTLC-MS. This proof of concept study opens up new possibilities of combining TLC with MS, and will further broaden the application abilities of TLC.

  7. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  8. Magnetic nanoparticles of nitrogen enriched carbon (mnNEC) for analysis of pesticides and metabolites in zebrafish by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhou, Youe; Xia, Qian; Ding, Mengjie; Kageruka, Hubert; Jiang, Haiying; Jiang, Yan; Jing, Huifen; Xiao, Xiao; Zhong, Hongying

    2013-02-01

    Nanosized carbon based sorbents have been widely used for separation, enrichment and desalting of biological samples because of their distinguished characteristics. In this work, magnetic nanoparticles of nitrogen enriched carbon (mnNEC) have been developed for enrichment of organochlorine pesticide DDT and metabolite DDE that have been accumulated in zebrafish during the course of environmental exposure. Polymerization of pyrrole was performed in the aqueous suspension of Fe(3)O(4) nanoparticles. Resultant core-shell nanoparticules coated with polypyrrole were then subjected to a process of carbonization under high temperature and nitrogen atmospheric condition. The presence of nitrogen atoms in carbon nanoparticles increases the hydrophilicity and dispersability in aqueous samples. It has been experimentally demonstrated that mnNEC can be effectively dispersed in aqueous samples and rapidly isolated by the application of an external magnetic field. Recoveries of DDT and DDE from water range from 90% to 102% and 85-97% respectively. In combination with Selected Ion Monitoring (SIM) experiments of gas chromatography-mass spectrometry, the detection limit can be down to low ng/mL level. By using mnNEC approach, two interesting results have been found for zebrafish with 60 days exposure to DDT (1 μg/l). (1) There is higher concentration of DDT (37-143 ng/g) and DDE (173-1108 ng/g) in male zebrafish body tissues than that of female (7-52 ng/g and 146-362 ng/g for DDT and DDE respectively). (2) There is high ratio of DDE/DDT for both female and male zebrafish, implying high environmental persistence and ongoing bioaccumulation.

  9. Evaluation of Costus afer Ker Gawl. in vitro anti-inflammatory activity and its chemical constituents identiifed using gas chromatography-mass spectrometry analysis

    Institute of Scientific and Technical Information of China (English)

    Godswill Nduka Anyasor; Onajobi Funmilayo; Osilesi Odutola; Adebawo Olugbenga; Efere Martins Oboutor

    2015-01-01

    Objective:To evaluate the anti-inflammatory activity of a tropical African medicinal plant, Costus afer (C. afer) Ker Gawl. in vitro and identify the chemical constituents in the most active fraction. Methods:Hexane, ethyl acetate, n-butanol and aqueous fractions obtained through successive solvent partitioning of 70%methanolic leaf or stem extracts of C. afer were subjected to in vitro anti-inflammatory screening assays viz. anti-denaturation of protein, stabilization of human red blood cell (HRBC) membrane against hypotonicity-induced hemolysis and anti-proteinase activities. Diclofenac sodium was used as a standard drug. The chemical compounds in the most active fraction were determined using quantitative phytochemical and gas chromatography-mass spectrometry (GC/MS) analytical methods, comparing the mass spectra of the GC/MS identified compounds with those of the National Institute of Standards and Technology (NIST) database library. Results:The hexane fraction of C. afer leaf (HFCAL) with an IC50 of 33.36μg/mL, 33μg/mL and 212.77 μg/mL exhibited the highest anti-denaturation of protein, stabilization of HRBC membrane and anti-proteinase activities respectively when compared with other test fractions. The GC/MS identified compounds in HFCAL known to possess anti-inflammatory property were terpenoids (naphthalene 1,6-dimethyl-; naphthalene 2,3-dimethyl-; phytol), phenol [phenol 2,4-bis(1,1-dimethylethyl)], coumaran [2(4H)-benzofuranone, 5,6,7,7a-tetrahydro-4, 4,7atrimethyl and fatty acids (pentadecanoic acid;hexadecanoic acid;n-hexadecanoic acid;9,12-octadecanoic acid-methyl ester;9,12,15 octadecatrienoic acid and cis-vaccenic acid)]. Conclusion: Therefore, HFCAL could be considered as a potential source of anti-inflammatory agents for herbal formulation or pharmaceutical drug production.

  10. Analysis of volatile oil in Rhizoma Ligustici Chuanxiong-Radix Paeoniae Rubra by gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    Xiao-ru LI; Yi-zeng LIANG; Fang-qiu GUO

    2006-01-01

    Aim:To analyze the volatile chemical components of the herbal pair Rhizoma Ligustici Chuanxiong-Radix Paeoniae Rubra (RLC-RPR) and compare them with those of each of the herbs alone.Methods:Gas chromatography-mass spectrometry (GC-MS) ,a chemometric resolution technique using the heuristic evolving latent projections (HELP) method.and the overall volume integration method were used.Results:In total,52,38,and 61 volatile chemical components in RLC,RPR,and RLC-RPR essential oils were determined,respectively,accounting for 95.14%,95.19%,and 89.68%ofthe total contents ofessential oil ofRLC,RPR,and RLC-RPR,respectively.The majn volatile chemical components were butyldienephthalide (20.65%) and ligustilide (50.15%) for RLC;and n-hexadecanoic acid (20.18%) ,[Z,Z]9,12-octadecadienoic acid (30.11%) ,2-hydroxy-benzaldehyde (17.08%) for RPR,and butyldienephthalide (14.80%) ,and ligustilide (38.91%) for RLC-RPR.The main volatile chemical components of RLC-RPR were almost the same as those of RLC,but the relative amounts were altered.Conclusion:The number of volatile chemical components in RLC-RPR was almost equal to the sum of the number in the 2 constituent herbs.but the relative amounts were altered.Furthermore,an acid-base reaction takes place during the process of decocting the herbs.The data gathered in this study may be helpful for understanding the synergistic nature of this herb pair in traditional Chinese medicine.

  11. MICELLAR ELECTROKINETIC CHROMATOGRAPHY-MASS SPECTROMETRY (R823292)

    Science.gov (United States)

    The combination of micellar electrokinetic chromatography (MEKC) with mass spectrometry (MS) is very attractive for the direct identification of analyte molecules, for the possibility of selectivity enhancement, and for the structure confirmation and analysis in a MS-MS mode. The...

  12. Methods of analysis by the U. S. Geological Survey National Water Quality Laboratory - determination of organonitrogen herbicides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Sandstrom, Mark W.; Wydoski, Duane S.; Schroeder, Michael P.; Zamboni, Jana L.; Foreman, William T.

    1992-01-01

    A method for the isolation of organonitrogen herbicides from natural water samples using solid-phase extraction and analysis by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction cartridges containing octadecyl-bonded porous silica to remove the herbicides. The cartridges are dried using carbon dioxide, and adsorbed herbicides are removed from the cartridges by elution with 1.8 milliliters of hexaneisopropanol (3:1). Extracts of the eluants are analyzed by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of at least three characteristic ions. The method detection limits are dependent on sample matrix and each particular herbicide. The method detection limits, based on a 100-milliliter sample size, range from 0.02 to 0.25 microgram per liter. Recoveries averaged 80 to 115 percent for the 23 herbicides and 2 metabolites in 1 reagent-water and 2 natural-water samples fortified at levels of 0.2 and 2.0 micrograms per liter.

  13. Quantitative analysis of trace levels ofβ-ionone in water by liquid-liquid- phase extraction-gas chromatography-mass spectrometry (LLE-GC-MS)

    Institute of Scientific and Technical Information of China (English)

    高梦鸿; 高乃云; 谢茴茴; 安娜; 邓扬; 戎文磊

    2015-01-01

    A simple and rapid technique based on liquid−liquid extraction coupled to gas chromatography-mass spectrometric detection (LLE-GC-MS) was developed for analysis of taste and odour compoundβ-ionone in water. Instrument parameters including programmed oven temperature, injection temperature and ion source temperature were evaluated and optimized. Effects of extraction time, ionic strength and pH on the detection efficiency were investigated and optimum conditions were 8 min of extraction time, without NaCl addition at pH=9. Good linearity (R2=0.9997) was obtained when the linear range was 10−500μg/L. The recoveries ofβ-ionone in ultrapure water and tap water samples were 88%−95% and 110%−114%, respectively. The relative standard deviations (RSD) were less than 10%. The method detection limit (MDL) and rejection quality level (RQL) were achieved at 1.98μg/L and 6.53μg/L, respectively. LLE-GC-MS was demonstrated to be a rapid and convenient method for the determination ofβ-ionone in water samples.

  14. Quantitative analysis of polar lipids in the nanoliter level of rat serum by liquid chromatography/mass spectrometry/mass spectrometry

    Science.gov (United States)

    Polar lipids in serum, including lysophospholipids (LPLs) and free fatty acids (FFAs), have a broad range of biological activities and require a suitable method for their quantitative analysis. Conventional methods use multistep procedures to simultaneously purify and analyze polar lipids and non-po...

  15. Multiresidue pesticide analysis of ginseng powders using acetonitrile- or acetone-based extraction, solid-phase extraction cleanup, and gas chromatography-mass spectrometry/selective ion monitoring (GC-MS/SIM) or -tandem mass spectrometry (GC-MS/MS).

    Science.gov (United States)

    Wong, Jon W; Zhang, Kai; Tech, Katherine; Hayward, Douglas G; Krynitsky, Alexander J; Cassias, Irene; Schenck, Frank J; Banerjee, Kaushik; Dasgupta, Soma; Brown, Don

    2010-05-26

    A multiresidue method for the analysis of 168 pesticides in dried powdered ginseng has been developed using acetonitrile or acetone mixture (acetone/cyclohexane/ethyl acetate, 2:1:1 v/v/v) extraction, solid-phase extraction (SPE) cleanup with octyl-bonded silica (C(8)), graphitized carbon black/primary-secondary amine (GCB/PSA) sorbents and toluene, and capillary gas chromatography-mass spectrometry/selective ion monitoring (GC-MS/SIM) or -tandem mass spectrometry (GC-MS/MS). The geometric mean limits of quantitation (LOQs) were 53 and 6 microg/kg for the acetonitrile extraction and 48 and 7 microg/kg for the acetone-based extraction for GC-MS/SIM and GC-MS/MS, respectively. Mean percent recoveries and standard deviations from the ginseng fortified at 25, 100, and 500 microg/kg using GC-MS/SIM were 87 +/- 10, 88 +/- 8, and 86 +/- 10% from acetonitrile extracts and 88 +/- 13, 88 +/- 12, and 88 +/- 14% from acetone mixture extracts, respectively. The mean percent recoveries from the ginseng at the 25, 100, and 500 microg/kg levels using GC-MS/MS were 83 +/- 19, 90 +/- 13, and 89 +/- 11% from acetonitrile extracts and 98 +/- 20, 91 +/- 13, and 88 +/- 14% from acetone extracts, respectively. Twelve dried ginseng products were found to contain one or more of the following pesticides and their metabolites: BHCs (benzene hexachlorides, alpha-, beta-, gamma-, and delta-), chlorothalonil, chlorpyrifos, DDT (dichlorodiphenyl trichloroethane), dacthal, diazinon, iprodione, quintozene, and procymidone ranging from 4000 microg/kg. No significant differences were found between the two extraction solvents, and GC-MS/MS was found to be more specific and sensitive than GC-MS/SIM. The procedures described were shown to be effective in screening, identifying, confirming, and quantitating pesticides in commercial ginseng products.

  16. 气相色谱-质谱联用分析倍花中化学成分%Compounds Analysis in Beihua by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    欧阳玉祝; 张辞海; 魏燕; 吴道宏

    2013-01-01

    Volatile oils and extracts were prepared from beihua.Compounds in volatile oil and fatty acids in extrats were analyzed by gas chromatography-mass spectrometry.The results showed that fifty compounds were detected from volatile oil with 17.94% of ethyl isopropyl ether,4.4% of hexanoic acid,3.43% of N,N-dimethylaniline,3.72% of dodecanoic acid,14.89% of tetradecanoic acid,8.88% of palmitic acid and 23.8% of cis,cis,cis-7,10,13-hexadecatrienal being the main components.Eighteen compounds were detected from extracts of methyl-esterification,and ten of them are fatty acids.The content of unsaturated fatty acids is 19.2% with linolenic acid being 16.13%,and that of saturated fatty acids is 51.7% with tetradecanoic acid and palmitic acid of 26.88% and 17.03%,respectively.%以植物倍花为原料制备倍花挥发油和倍花提取液,用气相色谱-质谱联用技术分析了挥发油的化学成分和提取液的脂肪酸组成与含量.实验结果表明,挥发油中共检出五十个组分,主要成分是乙基异丙醚、己酸、N,N-二甲基苯胺、月桂酸、肉豆蔻酸、棕榈酸、7(Z),10(Z),13 (Z)-十六碳三烯酮,其相对含量分别为17.94%、4.48%、3.43%、3.72%、14.89%、8.88%、23.8%.倍花提取液经甲酯化后共检出十八种物质,其中有十种脂肪酸,不饱和脂肪酸与饱和脂肪酸总含量分别为19.2%和51.7%;不饱和脂肪酸中亚麻酸含量达16.13%,饱和脂肪酸主要是肉豆蔻酸和棕榈酸,含量分别为26.88%和17.03%.

  17. Quantitative analysis of aberrant fatty acid composition of zebrafish hepatic lipids induced by organochlorine pesticide using stable isotope-coded transmethylation and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhong, Hongying; Dong, Linjie; Dong, Qingjian; Ke, Changshu; Fu, Jieying; Wang, Xiaoli; Liu, Cong; Dai, Ling

    2012-07-01

    Organochlorine pesticides have been extensively used worldwide for agricultural purposes. Due to their resistance to metabolism, a major public health concern has been raised. Aberrant hepatic lipid composition has been a hallmark of many liver diseases associated with exposure to various toxins and chemicals. And thus lots of efforts have been focused on the development of analytical techniques that can rapidly and quantitatively determine the changes in fatty acid composition of hepatic lipids. In this work, changes in fatty acid composition of hepatic lipids in response to DDT (dichlorodiphenyltrichloroethane) exposure were quantitatively analyzed by a gas chromatography-mass spectrometric approach based on stable isotope-coded transmethylation. It has been quantitatively demonstrated that polyunsaturated fatty acids including C20:3n3, C20:4n6, and C22:6n3 decrease in response to DDT exposure. However, saturated long chain fatty acids including C16:0, C18:0, as well as monounsaturated long chain fatty acid C18:1n9 consistently increase in a DDT-concentration-dependent manner. In particular, much higher changes in the level of hepatic C16:0 and C18:0 for male fish were observed than that for female fish. These experimental results are in accordance with qualitative histopathological analysis that revealed liver morphological alterations. The stable isotope-coded mass spectrometric approach provides a reliable means for investigating hepatotoxicity associated with fatty acid synthesis, desaturation, mitochondrial beta-oxidation, and lipid mobilization. It should be useful in elucidation of hepatotoxic mechanisms and safety assessment of environmental toxins.

  18. Comprehensive analysis of a multidimensional liquid chromatography mass spectrometry dataset acquired on a quadrupole selecting, quadrupole collision cell, time-of-flight mass spectrometer: I. How much of the data is theoretically interpretable by search engines?

    Science.gov (United States)

    Chalkley, Robert J; Baker, Peter R; Hansen, Kirk C; Medzihradszky, Katalin F; Allen, Nadia P; Rexach, Michael; Burlingame, Alma L

    2005-08-01

    An in-depth analysis of a multidimensional chromatography-mass spectrometry dataset acquired on a quadrupole selecting, quadrupole collision cell, time-of-flight (QqTOF) geometry instrument was carried out. A total of 3269 CID spectra were acquired. Through manual verification of database search results and de novo interpretation of spectra 2368 spectra could be confidently determined as predicted tryptic peptides. A detailed analysis of the non-matching spectra was also carried out, highlighting what the non-matching spectra in a database search typically are composed of. The results of this comprehensive dataset study demonstrate that QqTOF instruments produce information-rich data of which a high percentage of the data is readily interpretable.

  19. Capillary supercritical fluid chromatography-mass spectrometry (SFC-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Kalinoski, H.T.; Udseth, H.R.; Chess, E.K.; Smith, R.D.

    1986-10-01

    The physical and chemical characteristics of supercritical fluids have prompted the development of supercritical fluid chromatography (SFC) for the analysis of labile and less volatile compounds. High resolution chromatographic separations with efficiencies approaching those of gas chromatography and high speed analyses are possible in capillary SFC using pressure programming methods and narrow bore columns. Further refinement of the SFC-mass spectrometry interface (SFC-MS) provides the basis for extension to more polar fluid systems with greater solvating power and the selectivity and sensitivity of mass spectrometric detection. The use of polar modified fluids has been facilitated by advances in understanding of supercritical fluid phase behavior. Fluid mixtures have been prepared for analysis of more polar, higher molecular weight analytes, that allow mild chromatographic temperatures and allow full exploitation of selectivity offered through control of fluid pressure (i.e., density). Continuing development of the SFC-MS interface has led to designs which can be near routinely applied with fluids such as CO/sub 2/, and providing enhanced transport of truly nonvolatile compounds to the mass spectrometer ionization regions. These advances also include an SFC interface to a high resolution, dual electric magnetic sector instrument, allowing supercritical fluid solvents to be explited for on-line extraction-mass spectrometry for characterization of complex, often otherwise intractable, materials. 26 refs., 5 figs., 1 tab.

  20. Pilot Study on Pyrolysis Analysis of Decabromodiphenyl Ether by Gas Chromatography-Mass Spectrometry%十溴二苯醚的裂解气相色谱-质谱初步研究

    Institute of Scientific and Technical Information of China (English)

    吴惠勤; 黄晓兰; 黄芳; 林晓珊; 李逸; 邓欣

    2004-01-01

    The pyrolysis products of decabromodiphenyl ether (DBDE)were researched using pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) and the thermal pyrolysis mechanism was discussed. The results showed the main pyrolysis products of decabromodiphenyl ether are boromoform, bromobenzene, tetrabromoethene, tetrabromobutadiene and tetrabromobenzene.

  1. ON-SITE SOLID-PHASE EXTRACTION AND LABORATORY ANALYSIS OF ULTRA-TRACE SYNTHETIC MUSKS IN MUNICIPAL SEWAGE EFFLUENT USING GAS CHROMATOGRAPHY-MASS SPECTROMETRY IN THE FULL-SCAN MODE

    Science.gov (United States)

    Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are requ...

  2. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    Science.gov (United States)

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-01

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  3. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    Science.gov (United States)

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  4. Enhancement of the capabilities of liquid chromatography-mass spectrometry with derivatization: general principles and applications.

    Science.gov (United States)

    Xu, Fengguo; Zou, Li; Liu, Ying; Zhang, Zunjian; Ong, Choon Nam

    2011-01-01

    The integration of liquid chromatography-mass spectrometry (LC-MS) with derivatization is a relatively new and unique strategy that could add value and could enhance the capabilities of LC-MS-based technologies. The derivatization process could be carried out in various analytical steps, for example, sampling, storage, sample preparation, HPLC separation, and MS detection. This review presents an overview of derivatization-based LC-MS strategy over the past 10 years and covers both the general principles and applications in the fields of pharmaceutical and biomedical analysis, biomarker and metabolomic research, environmental analysis, and food-safety evaluation. The underlying mechanisms and theories for derivative reagent selection are summarized and highlighted to guide future studies.

  5. A Gas Chromatography-Mass Spectrometry Based Study on Urine Metabolomics in Rats Chronically Poisoned with Hydrogen Sulfide

    OpenAIRE

    Mingjie Deng; Meiling Zhang; Fa Sun; Jianshe Ma; Lufeng Hu; Xuezhi Yang; Guanyang Lin; Xianqin Wang

    2015-01-01

    Gas chromatography-mass spectrometry (GS-MS) in combination with multivariate statistical analysis was applied to explore the metabolic variability in urine of chronically hydrogen sulfide- (H2S-) poisoned rats relative to control ones. The changes in endogenous metabolites were studied by partial least squares-discriminate analysis (PLS-DA) and independent-samples t-test. The metabolic patterns of H2S-poisoned group are separated from the control, suggesting that the metabolic profiles of H2...

  6. Determination of constituents of essential oil from Angelica sinensis by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU Ming-jian; SUN Xian-jun; DAI Yuan-hui; GUO Fang-qiu; HUANG Lan-fang; LIANG Yi-zeng

    2005-01-01

    Gas chromatography-mass spectrometry (GC-MS) coupled with chemometric resolution upon two-dimensional data was employed to analyze the constituents of essential oils of Angelica sinensis. Constituents in essential oils of Angelica sinensis root were identified by GC-MS with the help of subwindow factor analysis (SFA) method resolving two-dimensional original data into mass spectra and chromatograms. 76 of 97 separated constituents in essential oil of Angelica sinensis root were identified and quantified, and they account for about 91.36% of the total content. The results show that ligustilide, butylene phthalide, 2-methoxy-4-vinylphenol, carvacrol, allo-ocimene,2,6,6-trimethylbicyclo-[3,1,1]hept-2-ene are the main constituents in essential oil of Angelica sinensis root.

  7. Electrospray liquid chromatography/mass spectrometry fingerprinting of Acanthophis (death adder) venoms: taxonomic and toxinological implications.

    Science.gov (United States)

    Fry, Bryan G; Wickramaratna, Janith C; Hodgson, Wayne C; Alewood, Paul F; Kini, R M; Ho, Hao; Wüster, Wolfgang

    2002-01-01

    Death adders (genus Acanthophis) are unique among elapid snakes in both morphology and venom composition. Despite this genus being among the most divergent of all elapids, the venom has been historically regarded as relatively quite simple. In this study, liquid chromatography/mass spectrometry (LC/MS) analysis has revealed a much greater diversity in venom composition, including the presence of molecules of novel molecular weights that may represent a new class of venom component. Furthermore, significant variation exists between species and populations, which allow for the LC/MS fingerprinting of each species. Mass profiling of Acanthophis venoms clearly demonstrates the effectiveness of this technique which underpins fundamental studies ranging from chemotaxonomy to drug design.

  8. Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Robbat, Albert; Considine, Thomas; Antle, Patrick M

    2010-09-01

    This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140 degrees C temperature limit restricts analyte collection in soil to C(2)-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater.

  9. Use of Gas Chromatography-Mass Spectrometry (GC-MS) in Nonscience Major Course Laboratory Experiments

    Science.gov (United States)

    Kostecka, Keith S.; Lerman, Zafra M.; Angelos, Sanford A.

    1996-06-01

    Gas chromatography-mass spectrometry (GC-MS) has been utilized with nonscience majors in the courses: "Modern Methods in Science: Discovering Molecular Secrets"; "The Extraordinary Chemistry of Ordinary Things"; "From Ozone to Oil Spills: Chemistry, the Environment and You"; and "Crime Lab Chemistry: Solving Crime through Analytical Chemistry". Our efforts have centered on introducing prospective science communicators (film, video, radio, television, and journalism majors) to science relative to their majors and personal interests. Quality lecture-discussion topics, "mystery"-based laboratory activities have assisted in introducing and/or explaining specific areas of chemistry that attempt to reduce fear of subject matter. Students have also used GC-MS, as a form of alternative assessment, in course projects that have been based on their majors, personal interests, and cultural backgrounds. Students have also conducted advanced independent work in different areas of chemistry, including the analysis of nail polishes and lacquers and eleven aromatic compounds present in three different brands of gasoline.

  10. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  11. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  12. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  13. Identifying Ca2+-Binding Sites in Proteins by Liquid Chromatography-Mass Spectrometry Using Ca2+-Directed Dissociations

    NARCIS (Netherlands)

    Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.

    2014-01-01

    Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry app

  14. Quasi-targeted analysis of hydroxylation-related metabolites of polycyclic aromatic hydrocarbons in human urine by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Tang, Caiming; Tan, Jianhua; Fan, Ruifang; Zhao, Bo; Tang, Caixing; Ou, Weihui; Jin, Jiabin; Peng, Xianzhi

    2016-08-26

    Metabolite identification is crucial for revealing metabolic pathways and comprehensive potential toxicities of polycyclic aromatic hydrocarbons (PAHs) in human body. In this work, a quasi-targeted analysis strategy was proposed for metabolite identification of monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in human urine using liquid chromatography triple quadruple mass spectrometry (LC-QqQ-MS/MS) combined with liquid chromatography high resolution mass spectrometry (LC-HRMS). Potential metabolites of OH-PAHs were preliminarily screened out by LC-QqQ-MS/MS in association with filtering in a self-constructed information list of possible metabolites, followed by further identification and confirmation with LC-HRMS. The developed method can provide more reliable and systematic results compared with traditional untargeted analysis using LC-HRMS. In addition, data processing for LC-HRMS analysis were greatly simplified. This quasi-targeted analysis method was successfully applied to identifying phase I and phase II metabolites of OH-PAHs in human urine. Five metabolites of hydroxynaphthalene, seven of hydroxyfluorene, four of hydroxyphenanthrene, and three of hydroxypyrene were tentatively identified. Metabolic pathways of PAHs in human body were putatively revealed based on the identified metabolites. The experimental results will be valuable for investigating the metabolic processes of PAHs in human body, and the quasi-targeted analysis strategy can be expanded to the metabolite identification and profiling of other compounds in vivo.

  15. Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method

    OpenAIRE

    Simona Nicoara; Loris Tonidandel; Pietro Traldi; Jonathan Watson; Geraint Morgan; Ovidiu Popa

    2009-01-01

    The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. T...

  16. Analysis of wine volatile profile by purge-and-trap-gas chromatography-mass spectrometry. Application to the analysis of red and white wines from different Spanish regions.

    Science.gov (United States)

    Aznar, Margarita; Arroyo, Teresa

    2007-09-21

    The purge-and-trap extraction method, coupled to a gas chromatograph with mass spectrometry detection, has been applied to the determination of 26 aromatic volatiles in wine. The method was optimized, validated and applied to the analyses of 40 red and white wines from 7 different Spanish regions. Principal components analyses of data showed the correlation between wines of similar origin.

  17. Detecting trace components in liquid chromatography/mass spectrometry data sets with two-dimensional wavelets

    Science.gov (United States)

    Compton, Duane C.; Snapp, Robert R.

    2007-09-01

    TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.

  18. Quantitation of acrylamide in food products by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Eberhart, B Loye; Ewald, Deborah K; Sanders, Robert A; Tallmadge, Daniel H; Zyzak, David V; Strothers, Melissa A

    2005-01-01

    A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.

  19. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  20. Advancing liquid chromatography- mass spectrometry based technologies for proteome research

    NARCIS (Netherlands)

    Boersema, P.J.

    2010-01-01

    In proteomics, high-tech nano-liquid chromatography (LC) and mass spectrometry (MS) instrumentation is used to routinely sequence proteins at a large scale. In this thesis, several technological developments are described to advance proteomics and their applicability is demonstrated in several diffe

  1. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    Science.gov (United States)

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  2. Direct thermal desorption in the analysis of cheese volatiles by gas chromatography and gas chromatography-mass spectrometry: comparison with simultaneous distillation-extraction and dynamic headspace.

    Science.gov (United States)

    Valero, E; Sanz, J; Martínez-Castro, I

    2001-06-01

    Direct thermal desorption (DTD) has been used as a technique for extracting volatile components of cheese as a preliminary step to their gas chromatographic (GC) analysis. In this study, it is applied to different cheese varieties: Camembert, blue, Chaumes, and La Serena. Volatiles are also extracted using other techniques such as simultaneous distillation-extraction and dynamic headspace. Separation and identification of the cheese components are carried out by GC-mass spectrometry. Approximately 100 compounds are detected in the examined cheeses. The described results show that DTD is fast, simple, and easy to automate; requires only a small amount of sample (approximately 50 mg); and affords quantitative information about the main groups of compounds present in cheeses.

  3. Analysis of volatile components in mosquito.repellent sticks by headspace-gas chromatography/mass spectrometry%顶空气相色谱质谱法分析避蚊贴中挥发性成分

    Institute of Scientific and Technical Information of China (English)

    徐昕荣; 区雪连; 马瑜璐; 朱斌

    2011-01-01

    采用顶空-气相色谱-质谱联用技术分析鉴定了4种避蚊贴中的挥发性物质.样品经90℃、45 min顶空后,采用GC-MS进行定性分析.用面积归一化法得出各组分的相对含量.结果表明:经NIST质谱数据库检索和文献对照,样品Ⅰ、Ⅱ、Ⅲ和Ⅳ分别检出并确定了33、39、39和24种成分.样品Ⅰ、Ⅱ、Ⅲ和Ⅳ主要成分分别为桉树醇(相对含量39.61%)、蒎烷(相对含量32.61%)、柠檬烯(相对含量34.40%)和为香茅醛(相对含量41.31%),其他成分主要为烯、醇、酮、醚等.%The volatile components of four mosquito-repellent sticks were analyzed by headspace-gas chromatography/mass spectrometry(HS-GC/MS). Samples were extracted at 90℃ for 45 min by headspace and separated by VOC capillary column, then were determined by gas chromatography-mass spectrometry. After normalization of peak areas, the relative contents of the identified compounds were obtained. The results showed that the samples Ⅰ、Ⅱ、Ⅲ and Ⅳ were detected and the components 33、39、39 and 24 were identified by comparing their mass spectra with those contained in the NIST mass spectrometry library and in some references literatures. The largest quantities of compounds of the samples Ⅰ、Ⅱ、Ⅲ and Ⅳ were eucalyptol ( relative content of 39.61% ) 、pinane ( relative content of 32.61% ) 、 limonene ( relative content of 34.40% ) and citronellal (relative content of 41.31%), respectively. In addition, other components were mainly alkene 、alcohol 、ketones and ether. The method is simple, rapid, accurate and suitable for the analysis of volatile flavor components in mosquito-repellent sticks.

  4. Multivariate analysis of the volatile components in tobacco based on infrared-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Yanqin; Pan, Yuanjiang; Zhou, Guojun; Chu, Guohai; Jiang, Jian; Yuan, Kailong; Xia, Qian; Cheng, Changhe

    2016-11-01

    A novel infrared-assisted extraction coupled to headspace solid-phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane-divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water-bath heating and nonheating extraction methods, the extraction efficiency of infrared-assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above-mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost-effective, and highly efficient method, the infrared-assisted extraction coupled to headspace solid-phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics.

  5. Recent progress in polar metabolite quantification in plants using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Zhiqian Liu; Simone Rochfort

    2014-01-01

    Metabolite analysis or metabolomics is an impor-tant component of systems biology in the post-genomic era. Although separate liquid chromatography (LC) methods for quantification of the major classes of polar metabolites of plants have been available for decades, a single method that enables simultaneous determination of hundreds of polar metabolites is possible only with gas chromatography-mass spectrometry (GC-MS) techniques. The rapid expansion of new LC stationary phases in the market and the ready access of mass spectrometry in many laboratories provides an excellent opportunity for developing LC-MS based methods for multi-target quantification of polar metabolites. Although various LC-MS methods have been developed over the last 10 years with the aim to quantify one or more classes of polar compounds in different matrices, currently there is no consensus LC-MS method that is widely used in plant metabolomics studies. The most promising methods applicable to plant metabolite analysis wil be reviewed in this paper and the major problems encountered highlighted. The aim of this review is to provide plant scientists, with limited to moderate experience in analytical chemistry, with up-to-date and simplified information regarding the current status of polar metabolite analysis using LC-MS techniques.

  6. β-sitosterol in different parts of Saraca asoca and herbal drug ashokarista: Quali-quantitative analysis by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Anjum Gahlaut

    2013-01-01

    Full Text Available β-sitosterol is an important component in food and herbal products and beneficial in hyperlipidemia. Its higher concentrations in serum may lead to coronary artery disease in case of sitosterolemia. Therefore, it is essential to determine the quantity of β-sitosterol in food and herbal drugs. Saraca asoca and its preparations have been widely used by traditional healers are also a source of β-sitosterol. In the present study, quantitative estimation of β-sitosterol present in hot and cold water extracts of bark, regenerated bark, leaves and flowers of the S. asoca and Ashokarista drugs were carried out first time using high performance liquid chromatography coupled (HPLC with quadrupole time-of-flight mass spectrometry. Different concentrations of β-sitosterol and crude extracts were estimated by HPLC and targeted mass spectrometry. Standard curve for β-sitosterol was prepared from the intensities of transitions (397.50 → 147.0987 m/z having regression coefficient (r 2 0.9952. Out of eight extracts and two drugs used in the study bark water, leaves water and leaves hot water extracts were found to have a considerable quantity of β-sitosterol, i.e. 170, 123.5 and 19.3 ng/mL, respectively. The results showed significant differences in the distribution of β-sitosterol among different organs of S. asoca and drugs prepared from its bark. HPLC/electrospray ionizationmass spectroscopy method is accurate, reproducible and requires less specimen, sample preparation and analysis time over HPLC assay. This type of approaches could be helpful for the quality control of herbal medicines and provides necessary information for the rational utilization of plant resources.

  7. Pentafluorobenzyl esterification of haloacetic acids in tap water for simple and sensitive analysis by gas chromatography/mass spectrometry with negative chemical ionization.

    Science.gov (United States)

    Zhao, Can; Fujii, Yukiko; Yan, Junxia; Harada, Kouji H; Koizumi, Akio

    2015-01-01

    Chlorine is the most widely used disinfectant for control of waterborne diseases in drinking water treatment. It can react with natural organic matter in water and form haloacetic acids (HAAs). For analysis of HAA levels, derivatization with diazomethane is commonly recommended as the standard methodology in Japan. However, diazomethane is a carcinogenic alkylating agent. Therefore, in this study, a safe, simple, and sensitive quantification method was developed to monitor HAAs in drinking water. Pentafluorobenzyl esterification was used for pretreatment. The pentafluorobenzyl-ester derivative was detected by gas chromatography-negative ion chemical ionization-mass spectrometry analysis with very high sensitivity for HAAs analysis. The method has low detection limits (8-94 ng L(-1)) and good recovery rates (89-99%) for HAAs. The method was applied to 30 tap water samples from 15 cities in the Kansai region of Japan. The levels of HAAs detected were in the range 0.54-7.83 μg L(-1). Dichloroacetic acid, trichloroacetic acid, and bromochloroacetic acid were the major HAAs detected in most of the tap water, and accounted for 29%, 20% and 19% of the total HAAs, respectively. This method could be used for routine monitoring of HAAs in drinking water without exposure of workers to occupational hazards.

  8. Analytical Variables Affecting Analysis of F2-Isoprostanes and F4-Neuroprostanes in Human Cerebrospinal Fluid by Gas Chromatography/Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hsiu-Chuan Yen

    2013-01-01

    Full Text Available F2-isoprostanes (F2-IsoPs are a gold marker of lipid peroxidation in vivo, whereas F4-neuroprostanes (F4-NPs measured in cerebrospinal fluid (CSF or brain tissue selectively indicate neuronal oxidative damage. Gas chromatography/negative-ion chemical-ionization mass spectrometry (GC/NICI-MS is the most sensitive and robust method for quantifying these compounds, which is essential for CSF samples because abundance of these compounds in CSF is very low. The present study revealed potential interferences on the analysis of F2-IsoPs and F4-NPs in CSF by GC/NICI-MS due to the use of improper analytical methods that have been employed in the literature. First, simultaneous quantification of F2-IsoPs and F4-NPs in CSF samples processed for F4-NPs analysis could cause poor chromatographic separation and falsely higher F2-IsoPs values for CSF samples with high levels of F2-IsoPs and F4-NPs. Second, retention of unknown substances in GC columns from CSF samples during F4-NPs analysis and from plasma samples during F2-IsoPs analysis might interfere with F4-NPs analysis of subsequent runs, which could be solved by holding columns at a high temperature for a period of time after data acquisition. Therefore, these special issues should be taken into consideration when performing analysis of F2-IsoPs and F4-NPs in CSF to avoid misleading results.

  9. Application of pyrolysis-gas chromatography-mass spectrometry and multivariate analysis to study bacteria and fungi in biofilms used for bioremediation.

    Science.gov (United States)

    Melucci, Dora; Fedi, Stefano; Locatelli, Marcello; Locatelli, Clinio; Montalbani, Simona; Cappelletti, Martina

    2013-08-01

    Biofilms are communities of microorganisms adhering to a surface and embedded in an extracellular polymeric matrix, frequently associated with disease and contamination, and also used for engineering applications such as bioremediation. A mixed biofilm formed by bacteria and fungi may provide an optimal habitat for addressing contaminated areas. To exploit the potential of natural microbial communities consisting of bacteria and fungi, it is essential to understand and control their formation. In this work, a method to discriminate among bacteria of genera Bacillus, Pseudomonas, Rhodococcus with respect to the fungus Pleorotus in a biofilm by means of pyrolysis-gaschromatography-mass spectrometry and multivariate analysis is reported. Methylated fatty acids were chosen as biomarkers of microorganisms in the pyrolysates. In situ thermal hydrolysis and methylation was applied. Pyrograms were used as fingerprints, thus allowing for the characterization of whole cells analyzed without any sample pretreatment. Normalized pyrographic peak areas were chosen as variables for chemometric data processing. Principal components analysis was applied as a data exploration tool. Satisfactory results were obtained in analyzing a real biofilm. The influence of growth medium on whole bacteria fatty acid cell composition was also explored.

  10. Nickel Oxide Nanoparticle-Deposited Silica Composite Solid-Phase Extraction for Benzimidazole Residue Analysis in Milk and Eggs by Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Sun, Huan; Yu, Qiong-Wei; He, Hai-Bo; Lu, Qian; Shi, Zhi-Guo; Feng, Yu-Qi

    2016-01-13

    A novel nickel oxide nanoparticle-deposited silica (SiO2@NiO) composite was prepared via liquid-phase deposition (LPD) and then employed as a solid-phase extraction (SPE) sorbent. When the SPE was coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI/MS) analysis, an analytical platform for the sensitive determination of benzimidazole residues in egg and milk was established. The limits of detection of nine benzimidazoles were in the range of 0.8-2.2 ng/mL in milk and 0.3-2.1 ng/g in eggs, respectively, which was 5-10 times superior to the methods with other adsorbents for SPE. The recoveries of nine benzimidazoles spiked in milk and egg ranged from 70.8 to 118.7%, with relative standard deviations (RSDs) being less than 18.9%. This work presented the excellent extraction performance of NiO on benzimidazoles for the first time, and the applicability of the LPD technique used as sorbents for trace analysis in complex matrices was also demonstrated.

  11. Nephron Toxicity Profiling via Untargeted Metabolome Analysis Employing a High Performance Liquid Chromatography-Mass Spectrometry-based Experimental and Computational Pipeline*

    Science.gov (United States)

    Ranninger, Christina; Rurik, Marc; Limonciel, Alice; Ruzek, Silke; Reischl, Roland; Wilmes, Anja; Jennings, Paul; Hewitt, Philip; Dekant, Wolfgang; Kohlbacher, Oliver; Huber, Christian G.

    2015-01-01

    Untargeted metabolomics has the potential to improve the predictivity of in vitro toxicity models and therefore may aid the replacement of expensive and laborious animal models. Here we describe a long term repeat dose nephrotoxicity study conducted on the human renal proximal tubular epithelial cell line, RPTEC/TERT1, treated with 10 and 35 μmol·liter−1 of chloroacetaldehyde, a metabolite of the anti-cancer drug ifosfamide. Our study outlines the establishment of an automated and easy to use untargeted metabolomics workflow for HPLC-high resolution mass spectrometry data. Automated data analysis workflows based on open source software (OpenMS, KNIME) enabled a comprehensive and reproducible analysis of the complex and voluminous metabolomics data produced by the profiling approach. Time- and concentration-dependent responses were clearly evident in the metabolomic profiles. To obtain a more comprehensive picture of the mode of action, transcriptomics and proteomics data were also integrated. For toxicity profiling of chloroacetaldehyde, 428 and 317 metabolite features were detectable in positive and negative modes, respectively, after stringent removal of chemical noise and unstable signals. Changes upon treatment were explored using principal component analysis, and statistically significant differences were identified using linear models for microarray assays. The analysis revealed toxic effects only for the treatment with 35 μmol·liter−1 for 3 and 14 days. The most regulated metabolites were glutathione and metabolites related to the oxidative stress response of the cells. These findings are corroborated by proteomics and transcriptomics data, which show, among other things, an activation of the Nrf2 and ATF4 pathways. PMID:26055719

  12. Analysis of Volatile Components in Semen Sojae Praepatum with Automatic Static Headspace and Gas Chromatography-Mass Spectrometry%静态顶空-气质联用分析淡豆豉中挥发性成分

    Institute of Scientific and Technical Information of China (English)

    柴川; 于生; 崔小兵; 张爱华; 朱栋; 单晨啸; 文红梅

    2013-01-01

    It was the first report on the volatile components contained in Semen Sojae Praepatum. For the analysis, the Semen Sojae Praepatum was analyzed by automatic static headspace and gas Chromatography-mass Spectrometry. A total of 27 compounds were identified in Semen Sojae Praepatum through the computer retrieval on the NIST5 mass spectral library. They consisted of 11 generality components, such as 2-Butanone, Butanal 3-methyl-, Butanal 2-methyl-, Limonene and 16 special components, such as copaene, Pyrazine, tetramethyl-, 2,3,5-Trimethyl-6-ethylpyrazine, Bicyclo[2.2.1]heptan-2-ol,1,7,7-trimethyl-,acetate,(1S-endo)-. Meanwhile, the quantitative analysis was taken using area normalization method, which showed that some difference was detected among six batches of Semen Sojae Praepatum. The results indicated that automatic static headspace and gas chromatography-mass spectrometry was a fast,easy,efficient and accurate method to analyze the volatile components in Semen Sojae Praepatum , and we thought that the findings may promote the fingerprint research of the volatile components in Semen Sojae Praepatum , to provide a scientific basis for the establishment of the quality standard.%  采用自动化静态顶空(HS)-气质联用(GC-MS)技术对6个批次淡豆豉的挥发性成分进行快速分析鉴定。从测定到的40多种成分中确定了2-丁酮、3-甲基丁醛、2-甲基丁醛、香芹烯等11种共有化合物及2,3,5-三甲基吡嗪、L-乙酸冰片酯、古巴烯、四甲基吡嗪等16种非共有化合物;同时使用峰面积归一化法计算了27种挥发性成分的相对含量,各组分的质量分数存在一定差异。研究表明,使用自动化静态顶空气质联用法测定淡豆豉的挥发性成分快速简便,且在一定程度上促进了淡豆豉挥发性成分的指纹图谱构建,为淡豆豉质量标准的建立提供了参考。

  13. Proteomic analysis of prolactinoma cells by immuno-laser capture microdissection combined with online two-dimensional nano-scale liquid chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chen Luping

    2010-01-01

    Full Text Available Abstract Background Pituitary adenomas, the third most common intracranial tumor, comprise nearly 16.7% of intracranial neoplasm and 25%-44% of pituitary adenomas are prolactinomas. Prolactinoma represents a complex heterogeneous mixture of cells including prolactin (PRL, endothelial cells, fibroblasts, and other stromal cells, making it difficult to dissect the molecular and cellular mechanisms of prolactin cells in pituitary tumorigenesis through high-throughout-omics analysis. Our newly developed immuno-laser capture microdissection (LCM method would permit rapid and reliable procurement of prolactin cells from this heterogeneous tissue. Thus, prolactin cell specific molecular events involved in pituitary tumorigenesis and cell signaling can be approached by proteomic analysis. Results Proteins from immuno-LCM captured prolactin cells were digested; resulting peptides were separated by two dimensional-nanoscale liquid chromatography (2D-nanoLC/MS and characterized by tandem mass spectrometry. All MS/MS spectrums were analyzed by SEQUEST against the human International Protein Index database and a specific prolactinoma proteome consisting of 2243 proteins was identified. This collection of identified proteins by far represents the largest and the most comprehensive database of proteome for prolactinoma. Category analysis of the proteome revealed a widely unbiased access to various proteins with diverse functional characteristics. Conclusions This manuscript described a more comprehensive proteomic profile of prolactinomas compared to other previous published reports. Thanks to the application of immuno-LCM combined with online two-dimensional nano-scale liquid chromatography here permitted identification of more proteins and, to our best knowledge, generated the largest prolactinoma proteome. This enlarged proteome would contribute significantly to further understanding of prolactinoma tumorigenesis which is crucial to the management of

  14. Gas Purge Microextraction Coupled with Stable Isotope Labeling-Liquid Chromatography/Mass Spectrometry for the Analysis of Bromophenols in Aquatic Products.

    Science.gov (United States)

    Zhang, Shijuan; Yu, Qiuhui; Sheng, Cuncun; You, Jinmao

    2016-12-14

    A green, sensitive, and accurate method was developed for the extraction and determination of bromophenols (BPs) from aquatic products by using organic solvent-free gas purge microsyringe extraction (GP-MSE) technique in combination with stable isotope labeling (SIL) strategy. BPs were extracted by NaHCO3 buffer solution, with recoveries varying from 92.0% to 98.5%. The extracted solution was analyzed by SIL strategy, during which analytes and standards were labeled by 10-methyl-acridone-2-sulfonyl chloride (d0-MASC) and its deuterated counterpart d3-MASC, respectively. The labeling reaction was finished within 10 min with good stability. The liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) sensitivity of BPs was greatly enhanced due to the mass-enhancing property of MASC, while the matrix effect was effectively minimized by the SIL strategy. The limits of detection (LODs) were in the range of 0.10-0.30 μg/kg, while the limits of quantitations (LOQs) were in the range of 0.32-1.0 μg/kg. The proposed method also showed great potential in the qualitative analysis of other bromophenols in the absence of standard.

  15. 司法案例中芬那露的气相色谱-质谱分析%Analysis of Chlormethazanone by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    张莉英; 张春水; 郑珲

    2004-01-01

    Chlormethazanone was a medicine used for calming, A method the determination of chlormethazanone in human stomach and liver tissue by gas chromatographic-mass spectrometry was developed. This method had been successfully applied into judicial identification.

  16. Tandem Extraction/Liquid Chromatography-Mass Spectrometry Protocol for the Analysis of Acrylamide and Surfactant-related Compounds in Complex Aqueous Environmental Samples

    Science.gov (United States)

    The development of a liquid chromatography‐mass spectrometry (LC‐MS)‐based strategy for the detection and quantitation of acrylamide and surfactant‐related compounds in aqueous complex environmental samples.

  17. Sensitive Determination of Onco-metabolites of D- and L-2-hydroxyglutarate Enantiomers by Chiral Derivatization Combined with Liquid Chromatography/Mass Spectrometry Analysis.

    Science.gov (United States)

    Cheng, Qing-Yun; Xiong, Jun; Huang, Wei; Ma, Qin; Ci, Weimin; Feng, Yu-Qi; Yuan, Bi-Feng

    2015-10-13

    2-hydroxyglutarate (2HG) is a potent competitor of α-ketoglutarate (α-KG) and can inhibit multiple α-KG dependent dioxygenases that function on the epigenetic modifications. The accumulation of 2HG contributes to elevated risk of malignant tumors. 2HG carries an asymmetric carbon atom in its carbon backbone and differentiation between D-2-hydroxyglutarate (D-2HG) and L-2-hydroxyglutarate (L-2HG) is crucially important for accurate diagnosis of 2HG related diseases. Here we developed a strategy by chiral derivatization combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis for highly sensitive determination of D-2HG and L-2HG enantiomers. N-(p-toluenesulfonyl)-L-phenylalanyl chloride (TSPC) was used to derivatize 2HG. The formed diastereomers by TSPC labeling can efficiently improve the chromatographic separation of D-2HG and L-2HG. And derivatization by TSPC could also markedly increase the detection sensitivities by 291 and 346 folds for D-2HG and L-2HG, respectively. Using the developed method, we measured the contents of D-2HG and L-2HG in clear cell renal cell carcinoma (ccRCC) tissues. We observed 12.9 and 29.8 folds increase of D-2HG and L-2HG, respectively, in human ccRCC tissues compared to adjacent normal tissues. The developed chiral derivatization combined with LC-ESI-MS/MS analysis offers sensitive determination of D-2HG and L-2HG enantiomers, which benefits the precise diagnosis of 2HG related metabolic diseases.

  18. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group?Determination of acetamide herbicides and their degradation products in water using online solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, E.A.; Strahan, A.P.

    2003-01-01

    An analytical method for the determination of 6 acetamide herbicides (acetochlor, alachlor, dimethenamid, flufenacet, metolachlor, and propachlor) and 16 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is described in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using octadecylsilane as the solid-phase extraction media on online automated equipment followed by liquid chromatography/mass spectrometry. The method uses only 10 milliliters of sample per injection. Three different water-sample matrices, a reagent-water, a ground-water, and a surface-water sample spiked at 0.10 and 1.0 microgram per liter, were analyzed to determine method performance. Method detection limits ranged from 0.004 to 0.051 microgram per liter for the parent acetamide herbicides and their degradation products. Mean recoveries for the acetamide compounds in the ground- and surface-water samples ranged from 62.3 to 117.4 percent. The secondary amide of acetochlor/metolachlor ethanesulfonic acid (ESA) was recovered at an average rate of 43.5 percent. The mean recoveries for propachlor and propachlor oxanilic acid (OXA) were next lowest, ranging from 62.3 to 95.5 percent. Mean recoveries from reagent-water samples ranged from 90.3 to 118.3 percent for all compounds. Overall the mean of the mean recoveries of all compounds in the three matrices spiked at 0.10 and 1.0 microgram per liter ranged from 89.9 to 100.7 percent, including the secondary amide of acetochlor/metolachlor ESA and the propachlor compounds. The acetamide herbicides and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter. The upper concentration limit is 2.0 micrograms per liter for all compounds without dilution. With the exception of the secondary amide of

  19. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group : determination of triazine and phenylurea herbicides and their degradation products in water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, Edward Alan; Strahan, Alex P.; Thurman, Earl Michael

    2002-01-01

    An analytical method for the determination of 7 triazine and phenylurea herbicides and 12 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is presented in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using 0.5 gram graphitized carbon as the solid-phase extraction media followed by liquid chromatography/mass spectrometry. Three different water-sample matrices?ground-water, surface-water, and reagent-water samples?spiked at 0.2 and 2.0 micrograms per liter were analyzed. Method detection limits ranged from 0.013 to 0.168 microgram per liter for the parent triazine herbicides and the triazine degradation products. Method detection limits ranged from 0.042 to 0.141 microgram per liter for the parent phenylurea herbicides and their degradation products. Mean recoveries for the triazine compounds in the ground- and surface-water samples generally ranged from 72.6 to 117.5 percent, but deethyl-cyanazine amide was recovered at 140.5 percent. Mean recoveries from the ground- and surface-water samples for the phenylurea compounds spiked at the 2.0-micrograms-per-liter level ranged from 82.1 to 114.4 percent. The mean recoveries for the phenylureas spiked at 0.2-microgram per liter were less consistent, ranging from 87.0 to 136.0 percent. Mean recoveries from reagent-water samples ranged from 87.0 to 109.5 percent for all compounds. The triazine compounds and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter, with the exception of deethylcyanazine and deethylcyanazine amide which are reported at 0.20 to 2.0 micrograms per liter. The phenylurea compounds and their degradation products are reported in concentrations ranging from 0.20 to 2.0 micrograms per liter. The upper concentration limit was 2

  20. Enantiomeric resolution of biomarkers in space analysis: Chemical derivatization and signal processing for gas chromatography-mass spectrometry analysis of chiral amino acids.

    Science.gov (United States)

    Pietrogrande, M C; Basaglia, G

    2010-02-12

    The work compares two GC-MS methods for enantioselective separation of amino acids as suitable candidate for stereochemical analysis of chiral amino acids on board spacecrafts in space exploration missions of solar system body environments. Different derivatization reagents are used: a mixture of alkyl chloroformate-alcohol-pyridine to obtain the alkyl alkoxy carbonyl esters and a mixture of perfluorinated alcohols and anhydrides to form perfluoroacyl perfluoroalkyl esters. 20 proteinogenic amino acids were derivatized with the two procedures and submitted to GC-MS analysis on a Chirasil-l-Val stationary phase. The results were then compared in terms of the enantiomeric separation achieved and intensity of MS response. The combination of methyl chloroformate (MCF) and heptafluoro-1-butanol (HFB) allows separation of 14 enantiomeric pairs, five of which display a resolution (R(s)>or=1.2) supposed to be sufficient to quantify the enantiomeric excess. Three mixtures of trifluoroacetic (TFAA) and heptafluorobutyric (HFBA) anhydrides were combined with the corresponding perfluorinated alcohols - TFE (2,2,2-trifluoro-1-ethanol) and HFB (2,2,3,3,4,4,4-heptafluoro-1-butanol) - to give three different reagents (TFAA-TFE, TFAA-HFB, HFBA-HFB): the derivatives obtained show separation of the same number of proteinogenic amino acids (14 of 20) at a temperature lower than column bleeding limit (200 degrees C) and 8 of them give a separation with R(s)>or=1.2. Linearity study and limit of detection (X(LOD)) computation show that both methods are suitable for quantitative determination of several amino acid diastereomers at trace level (X(LOD) approximately 0.5nmol as derivatized quantity). Both the procedures were coupled with automatic data handling to increase their suitability for space analysis: the simplified data treatment is especially helpful to handle the low quality data recovered from space experiments and labor and time are saved, as imposed by the space experiments

  1. Analysis and quantitation of volatile organic compounds emitted from plastics used in museum construction by evolved gas analysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Samide, Michael J; Smith, Gregory D

    2015-12-24

    Construction materials used in museums for the display, storage, and transportation of artwork must be assessed for their tendency to emit harmful pollution that could potentially damage cultural treasures. Traditionally, a subjective metals corrosion test known as the Oddy test has been widely utilized in museums for this purpose. To augment the Oddy test, an instrumental sampling approach based on evolved gas analysis (EGA) coupled to gas chromatography (GC) with mass spectral (MS) detection has been implemented for the first time to qualitatively identify off-gassed pollutants under specific conditions. This approach is compared to other instrumental methods reported in the literature. This novel application of the EGA sampling technique yields several benefits over traditional testing, including rapidity, high sensitivity, and broad detectability of volatile organic compounds (VOCs). Furthermore, unlike other reported instrumental approaches, the EGA method was used to determine quantitatively the amount of VOCs emitted by acetate resins and polyurethane foams under specific conditions using both an external calibration method as well as surrogate response factors. EGA was successfully employed to rapidly characterize emissions from 12 types of common plastics. This analysis is advocated as a rapid pre-screening method to rule out poorly performing materials prior to investing time and energy in Oddy testing. The approach is also useful for rapid, routine testing of construction materials previously vetted by traditional testing, but which may experience detrimental formulation changes over time. As an example, a case study on batch re-orders of rigid expanded poly(vinyl chloride) board stock is presented.

  2. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    2016-01-01

    Background A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated. Results This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recovery of analyte ...

  3. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    Shah, Iltaf; Barker, James; Naughton, Declan P; Barton, Stephen J.; Ashraf, Syed Salman

    2016-01-01

    Background\\ud A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated.\\ud \\ud Results\\ud This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recover...

  4. Evaluation of noni (Morinda citrifolia) volatile profile by dynamic headspace and gas chromatography-mass spectrometry

    OpenAIRE

    Sousa, A.; M. A. SOUZA NETO; GARRUTI, D. dos S.; Sousa, J. A.; BRITO, E. S. de

    2010-01-01

    Noni is a fruit that has interested the scientific community due to its medicinal and functional activities. Different products that contain noni are already in the market, but their consumption could be impaired by their distinctive unpleasant aroma and flavor. The aim of this work was to evaluate the noni pulp volatile profile by dynamic headspace and gas chromatography-mass spectrometry. Thirty seven volatile compounds were detected, mainly alcohols (63.3%), esters (26.9%), cetones (7.4%),...

  5. Construction and analysis of correlation networks based on gas chromatography-mass spectrometry metabonomics data for lipopolysaccharide-induced inflammation and intervention with volatile oil from Angelica sinensis in rats.

    Science.gov (United States)

    Hua, Yong-li; Ji, Peng; Xue, Zi-yu; Wei, Yan-ming

    2015-11-01

    Angelica sinensis (AS) is a well-known important traditional Chinese medicine that yields a volatile oil with anti-inflammatory effects. However, the holistic therapeutic effects and the mechanism underlying such effects of the volatile oil of A. sinensis (VOAS) are not yet well understood. Here, a gas chromatography-mass spectrometry-based metabonomic study was conducted to explore the significantly altered metabolites for better understanding of VOAS and to assess the integral efficacy of VOAS on a lipopolysaccharide (LPS)-induced inflammation rat model. Principal component analysis was used to investigate the global metabonomic alterations and to evaluate the therapeutic effects of VOAS in rats. Clear separations were observed in the comparison of the metabolite profiles of the normal control (NC) group, the LPS-stimulated group (MI), the VOAS group, and the dexamethasone (Dex) group. VOAS exerted therapeutic effects on the LPS-stimulated group, which were in accordance with the results of cytokine analyses and blood physiobiochemical assay. Furthermore, a total of 20, 17, and 22 metabolites distributed in 27 metabolic pathways were respectively identified in plasma, liver, and lung samples as significantly altered metabolites of MI, VOAS, Dex, and NC of the same background. Network analysis revealed that glycine, glutamate, malic acid, succinate, arachidonic acid, glycerol, galactose, and glucose were hub metabolites of the inflammation correlation network. Results indicated that VOAS exhibited an anti-inflammatory effect by adjusting the Krebs cycle, improving the glucose content, and restoring the fatty acid metabolism.

  6. Gas Chromatography-Mass Spectrometry (GC-MS Analysis of Indole Alkaloids Isolated from Catharanthus roseus (L. G. Don Cultivated Conventionally and Derived from In vitro Cultures

    Directory of Open Access Journals (Sweden)

    Aneta WESOŁOWSKA

    2016-06-01

    Full Text Available Catharanthus roseus (periwinkle is a medicinal plant commonly known for its wide biological activity. In many countries different parts of this plant are used for the treatment of diabetes, hypertension and for menstrual regulation. Due to the ability of production of alkaloids, which can be applied in cancer therapy, is still extensively investigated. Two, the most valuable alkaloids (vincristine and vinblastine are present in C. roseus in very low concentrations. Micropropagation is promising technique used to enhance the level of important secondary metabolites. The main objective of present study was alkaloids extraction from plants cultivated conventionally and derived from in vitro cultures. In this order the aerial parts of periwinkle were extracted with 96% ethanol at room temperature (method I and heated with 96% ethanol at 55 °C for 90 minutes (method II. The obtained mixtures of different indole alkaloids were analyzed by gas chromatography – mass spectrometry (GC-MS. Analysis revealed the presence of 15 alkaloids, among which vindoline, vindorosine, isovindolinine and ajmalicine were the most abundant. The obtained results indicated that the propagation method had a significant effect on the percentage content of alkaloids in C. roseus herb. Plants derived from in vitro cultures were richer in vindorosine and vindoline, while conventionally cultivated – in tetrahydroalstonine and ajmalicine. Moreover, in case of isovindolinine, vindolinine and ajmalicine, extraction at 55 °C was more effective, while for pericyclivine – maceration at room temperature. Interestingly, the pericyclivine was not detected in the mixture of alkaloids obtained from periwinkle herb by the extraction at 55 °C.

  7. Online capillary solid-phase microextraction coupled liquid chromatography-mass spectrometry for analysis of chiral secondary alcohol products in yeast catalyzed stereoselective reduction cell culture.

    Science.gov (United States)

    Cheng, Cheanyeh; Nian, Yu-Chuan

    2015-02-06

    An online solid-phase microextraction coupled liquid chromatography-electrospray ionization-ion trap mass spectrometry was developed for the analysis of trace R- and S-4-phenyl-2-butanol (R- and S-pbol) in salt rich cell culture of Saccharomyces cerevisiae catalyzed stereoselective reduction of 4-pheny-2-butanone (pbone). A Supel-Q PLOT capillary column was used for the extraction and deionized distilled water was used as the extraction mobile phase. The extraction flow rate and extraction time were at 0.1 mL min(-1) and 0.95 min, respectively. The three target analytes, pbone, R-pbol, and S-4-pbol, were desorbed and eluted by the mobile phase of water/methanol/isopropanol (55/25/20, v/v/v) with a flow rate of 0.5 mL min(-1) and analyzed by a chiral column. The mass spectrometric detection of the three target analytes was in positive ion mode with the signal [M+Na](+). The matrix-matched external standard calibration curves with linear concentration range between 0 and 50 μg mL(-1) were used for quantitative analysis. The linear regression correlation coefficients (r(2)) of the standard calibration curves were between 0.9950 and 0.9961. The yeast mediated reduction was performed with a recation culture of yeast incubation culture/glycerol (70/30, v/v) for 4 days. This biotransformation possessed 82.3% yield and 92.9% S-enantomeric excess. The limit of detection (LOD)/limit of quantification (LOQ) for pbone, R-pbol, and S-pbol was 0.02/0.067, 0.01/0.033, and 0.01/0.033 μg mL(-1), respectively. The intra-day and inter-day precisions from repeated measurements were 10.8-21.1% and 11.6-18.7%, respectively. The analysis accuracy from spike recovery was 84-91%.

  8. Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    Science.gov (United States)

    Freeman, K. H.; Ricci, S. A.; Studley, A.; Hayes, J. M.

    1989-01-01

    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

  9. Factors That Contribute to Assay Variation in Quantitative Analysis of Sex Steroid Hormones Using Liquid and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Xu, Xia; Veenstra, Timothy D.

    2012-01-01

    The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…

  10. Serum Metabonomics Analysis of Phlegm and Blood Stasis Syndrome in Patients with Coronary Heart Disease by Gas Chromatogra-phy Mass Spectrometry Combined with Liquid Chromatography Mass Spectrometry%基于气相色谱质谱联用对冠心病“痰”“瘀”证候血清代谢组学的研究

    Institute of Scientific and Technical Information of China (English)

    鹿小燕; 顾焕; 徐浩; 赵铁; 李耿

    2016-01-01

    Objective To investigate the serum metabonomics characteristics of phlegm and blood stasis syndrome in patients with coronary heart disease(CHD).Methods Metabolites spectral differences were compared between 102 patients with CHD (52 pa-tients with phlegm syndrome and 51 with blood stasis syndrome)and 31 healthy individuals by analysis techniques of gas chromatog-raphy– mass spectrometry (GC MS),liquid chromatography mass spectrometry (LC/MS)and pattern recognition technology.Re-sults CHD group compared to healthy controls showed obvious difference in the metabolites including many kinds of amino acids, organic acids,long chain fatty acids,lysophospholipids,phospholipids,sphingomyelin;the most different metabolites also were com-mon metabolites of phlegm and blood stasis group.The contents of organic acids,maltose,a variety of amino acids in CHD patients obviously increased than that in healthy control;while the contents of a variety of unsaturated fatty acids,derivatives,VitE,and cho-lesterol obviously decreased in CHD patients.Characteristic different metabolites in phlegm group and blood stasis group were mainly malic acid and succinic acid,fructose and glucose,glycine and alanine and palmitoleic acid.Among them,in phlegm group the con-tents of 7,10 Hexadecadienoic acid and DPA reduced,while the rest of them in blood stasis group increased.Conclusion CHD had specific metabolic group characteristics,phlegm and blood stasis had both characteristic different metabolites,also had common me-tabolites,which had important significance in improving identification ability of phlegm and blood stasis syndrome of coronary heart disease,also provided objective basis for CHD syndrome essence research.Phlegm and blood stasis had common material basis, which was coincident with Chinese medicine phlegm and blood stasis homologous theory. As pathogenic factors,both in the body could change into each other,and caused disease commonly,so treating phlegm and blood stasis

  11. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  12. Analysis of gamma-hydroxybutyric acid (GHB) in spiked water and beverage samples using solid phase microextraction (SPME) on fiber derivatization/gas chromatography-mass spectrometry (GC/MS).

    Science.gov (United States)

    Meyers, Jodi E; Almirall, José R

    2005-01-01

    Gamma-Hydroxybutyric acid (GHB) is a CNS depressant that has been abused recreationally for its purported euphoric and relaxation effects and for the purposes of drug facilitated sexual assault due to its sedative and amnesic effects at higher doses. The dramatic increase in the abuse of GHB and association in criminal investigations over the past decade has created the need for forensic laboratories to develop analytical methods to detect GHB in a variety of matrices. The method developed in this work used solid-phase microextraction (SPME) to extract GHB from aqueous samples followed by on-fiber derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). This method detected GHB in aqueous matrices with good sensitivity, high precision, excellent linearity from 0.01 mg/mL to 0.25 mg/mL, and without the need for sample manipulation that could cause interconversion between GHB and its lactone, GBL. The method was successfully applied for detection of GHB in spiked water and beverage samples.

  13. Methods of analysis and quality-assurance practices of the U.S. Geological Survey organic laboratory, Sacramento, California; determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Crepeau, Kathryn L.; Domagalski, Joseph L.; Kuivila, Kathryn M.

    1994-01-01

    Analytical method and quality-assurance practices were developed for a study of the fate and transport of pesticides in the Sacramento-San Joaquin Delta and the Sacramento and San Joaquin River. Water samples were filtered to remove suspended parti- culate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide, and the pesticides were eluted with three 2-milliliter aliquots of hexane:diethyl ether (1:1). The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for analytes determined per 1,500-milliliter samples ranged from 0.006 to 0.047 microgram per liter. Recoveries ranged from 47 to 89 percent for 12 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.05 and 0.26 microgram per liter. The method was modified to improve the pesticide recovery by reducing the sample volume to 1,000 milliliters. Internal standards were added to improve quantitative precision and accuracy. The analysis also was expanded to include a total of 21 pesticides. The method detection limits for 1,000-milliliter samples ranged from 0.022 to 0.129 microgram per liter. Recoveries ranged from 38 to 128 percent for 21 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.10 and 0.75 microgram per liter.

  14. Data preprocessing method for liquid chromatography-mass spectrometry based metabolomics.

    Science.gov (United States)

    Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S; Binkley, Joe; McClain, Craig; Zhang, Xiang

    2012-09-18

    A set of data preprocessing algorithms for peak detection and peak list alignment are reported for analysis of liquid chromatography-mass spectrometry (LC-MS)-based metabolomics data. For spectrum deconvolution, peak picking is achieved at the selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into the z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers demonstrates that the developed data preprocessing method performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS(2), for peak picking, peak list alignment, and quantification.

  15. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry.

    Science.gov (United States)

    Brust, Hanneke; Willemse, Sander; Zeng, Tuoyu; van Asten, Arian; Koeberg, Mattijs; van der Heijden, Antoine; Bolck, Annabel; Schoenmakers, Peter

    2014-12-29

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed in 4min. This study shows that impurity profiling of TNT can be used to investigate relations between TNT samples encountered in forensic casework. A wide variety of TNT samples were analyzed with the developed method. Dinitrobenzene, dinitrotoluene, trinitrotoluene and amino-dinitrotoluene isomers were detected at very low levels (<1wt.%) by applying the MS in selected-ion monitoring (SIM) mode. Limits of detection ranged from 6ng/mL for 2,6-dinitrotoluene to 43ng/mL for 4-amino-2,6-dinitrotoluene. Major impurities in TNT were 2,4-dinitrotoluene and 2,3,4-trinitrotoluene. Impurity profiles based on seven compounds showed to be useful to TNT samples from different sources. Statistical analysis of these impurity profiles using likelihood ratios demonstrated the potential to investigate whether two questioned TNT samples encountered in forensic casework are from the same source.

  16. Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    HUANG Lan-fang; WU Ming-jian; SUN Xian-jun; ZHONG Ke-jun; GUO Zi-ming; DAI Yun-hui; HUANG Ke-long; GUO Fang-qiu

    2007-01-01

    Chromatography-mass spectrometry (GC-MS) was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections (HELP). After extracting with simultaneous distillation and extraction method, the volatile components in cut tobacco were detected by GC-MS. Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms. The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST) mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response. The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra. 107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 88.01% of the total content. The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.

  17. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  18. Identification and differentiation of dragon's blood in works of art using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Baumer, Ursula; Dietemann, Patrick

    2010-06-01

    Dragon's blood is a common but non-specific name for red-coloured resins that are produced by various plants, particularly exudations from plant species belonging to the genera Dracaena and Daemonorops. Although dragon's blood is mentioned in historic sources as a colourant, it has hardly ever been identified in real artworks. This paper reports the identification and discrimination of dragon's blood produced by Dracaena cinnabari, Dracaena draco as well as Daemonorops draco and Daemonorops micracantha by means of gas chromatography/mass spectrometry (GC/MS) within the context of a routine analysis of binding media used in works of art. The detection of specific flavonoid marker compounds in both underivatised and methylated methanol extracts provided the first evidence for the use of dragon's blood from all four species in various works of art from the fifteenth to nineteenth centuries. Dragon's blood was mainly used as a red colourant in gold lacquers as well as translucent glazes and paints, e.g. in reverse-glass paintings (Hinterglasmalerei).

  19. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively.

  20. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    Science.gov (United States)

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased.

  1. 白酒中乙酯类成分的气相色谱-质谱分析%Analysis of Ester in Some Spirit by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    骆传环; 黄荣清; 肖炳坤; 梁乾德

    2004-01-01

    To determine fragrance character of Spirit “Bai” from Shandong. Spirit “Lu”was positive control, “Er”, egative control, three samples were extracted with either,then analyzed qualitatively and quantitatively with ISTD N-amyl acetate (EP) by gas chromatography-mass spectrometry (GC/MS). Fragranter components including ethyl acid ester(E),butanotic acid ester (B),lactic acid ester (L), pentoic acid ester(p), and hexanoic acid ester(H) were chosen. The result showed that the level of esters were higher in Bai close to “Lu”, so “Bai” can be called concentration fragrant type spirit.

  2. Identification of potentially toxic compounds in complex extracts of environmental samples using gas chromatography-mass spectrometry and multivariate data analysis.

    Science.gov (United States)

    Bergknut, Magnus; Kucera, Adam; Frech, Kristina; Andersson, Erika; Engwall, Magnus; Rannug, Ulf; Koci, Vladimir; Andersson, Patrik L; Haglund, Peter; Tysklind, Mats

    2007-02-01

    In this study, we examined 31 samples of varying chemical composition, including samples of soils from gasworks, coke production sites, and sites where wood preservatives were heavily used; ash and soot from municipal solid waste incinerators; antiskid sand; and dust from areas with heavy road traffic. The samples were comprehensively chemically characterized, especially their polycyclic aromatic compound contents, using gas chromatography-time-of-flight mass spectrometry, whereas their biological effects were assessed using dehydrogenase activity, root growth (Hordeum vulgare), reproduction of springtails (Folsomia candida), algal growth (Desmodesmus subspicatus), germinability (Sinapis alba), Vibrio fischeri, DR-CALUX, and Ames Salmonella assays. The number of compounds detected in the samples ranged from 123 to 527. Using the multivariate regression technique of partial-least-squares projections to latent structures, it was possible to find individual compounds that exhibited strong correlations with the different biological responses. Some of the results, however, indicate that a broader chemical characterization may be needed to identify all the compounds that may cause the measured biological responses.

  3. Optimization of solid-phase extraction for the liquid chromatography-mass spectrometry analysis of harpagoside, 8-para-coumaroyl harpagide, and harpagide in equine plasma and urine.

    Science.gov (United States)

    Colas, Cyril; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves; Bouchonnet, Stéphane

    2008-02-01

    Solid-phase extraction cartridges among those usually used for screening in horse doping analyses are tested to optimize the extraction of harpagoside (HS), harpagide (HG), and 8-para-coumaroyl harpagide (8PCHG) from plasma and urine. Extracts are analyzed by liquid chromatography coupled with multi-step tandem mass spectrometry. The extraction process retained for plasma applies BondElut PPL cartridges and provides extraction recoveries between 91% and 93%, with RSD values between 8 and 13% at 0.5 ng/mL. Two different procedures are needed to extract analytes from urine. HS and 8PCHG are extracted using AbsElut Nexus cartridges, with recoveries of 85% and 77%, respectively (RSD between 7% and 19%). The extraction of HG involves the use of two cartridges: BondElut PPL and BondElut C18 HF, with recovery of 75% and RSD between 14% and 19%. The applicability of the extraction methods is determined on authentic equine plasma and urine samples after harpagophytum or harpagoside administration.

  4. The detection and quantitative analysis of the psychoactive component of Salvia divinorum, salvinorin A, in human biological fluids using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    McDonough, Pamela C; Holler, Justin M; Vorce, Shawn P; Bosy, Thomas Z; Magluilo, Joseph; Past, Marilyn R

    2008-01-01

    Salvia divinorum, a member of the mint plant family, has hallucinogenic properties that have become increasingly sought after by recreational drug users. The main psychoactive component, salvinorin A, has potency comparable to lysergic acid diethylamide. Though still legal to possess in most of the United States and much of Europe, little is known regarding the compound's long-term health effects, addiction liability, and pharmacokinetics. Limited data are available in the scientific literature, and few analytical methods are published for the detection in human biological fluids. These factors contribute to the unfamiliarity of the compound and complicate the method development process necessary to accommodate special requested testing for salvinorin A. A sensitive analytical method for the detection and quantitation of salvinorin A in human biological fluids was developed and validated to resolve analytical shortcomings. The method utilizes a solid-phase extraction technique coupled with liquid chromatography-electrospray ionization mass spectrometry operated in selected ion monitoring mode. The assay has a linear range of 5.0-100 ng/mL with a correlation coefficient of 0.997. The limit of detection and limit of quantitation were experimentally determined as 2.5 and 5.0 ng/mL, respectively. The method has been applied to blood and urine samples successfully and can be used to detect the presence of salvinorin A in forensic testing.

  5. Preliminary construction of integral analysis for characteristic components in complex matrices by in-house fabricated solid-phase microextraction fibers combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tang, Zhentao; Hou, Wenqian; Liu, Xiuming; Wang, Mingfeng; Duan, Yixiang

    2016-08-26

    Integral analysis plays an important role in study and quality control of substances with complex matrices in our daily life. As the preliminary construction of integral analysis of substances with complex matrices, developing a relatively comprehensive and sensitive methodology might offer more informative and reliable characteristic components. Flavoring mixtures belonging to the representatives of substances with complex matrices have now been widely used in various fields. To better study and control the quality of flavoring mixtures as additives in food industry, an in-house fabricated solid-phase microextraction (SPME) fiber was prepared based on sol-gel technology in this work. The active organic component of the fiber coating was multi-walled carbon nanotubes (MWCNTs) functionalized with hydroxyl-terminated polydimethyldiphenylsiloxane, which integrate the non-polar and polar chains of both materials. In this way, more sensitive extraction capability for a wider range of compounds can be obtained in comparison with commercial SPME fibers. Preliminarily integral analysis of three similar types of samples were realized by the optimized SPME-GC-MS method. With the obtained GC-MS data, a valid and well-fit model was established by partial least square discriminant analysis (PLS-DA) for classification of these samples (R2X=0.661, R2Y=0.996, Q2=0.986). The validity of the model (R2=0.266, Q2=-0.465) has also approved the potential to predict the "belongingness" of new samples. With the PLS-DA and SPSS method, further screening out the markers among three similar batches of samples may be helpful for monitoring and controlling the quality of the flavoring mixtures as additives in food industry. Conversely, the reliability and effectiveness of the GC-MS data has verified the comprehensive and efficient extraction performance of the in-house fabricated fiber.

  6. Development of a dynamic headspace gas chromatography-mass spectrometry method for on-site analysis of sulfur mustard degradation products in sediments.

    Science.gov (United States)

    Magnusson, R; Nordlander, T; Östin, A

    2016-01-15

    Sampling teams performing work at sea in areas where chemical munitions may have been dumped require rapid and reliable analytical methods for verifying sulfur mustard leakage from suspected objects. Here we present such an on-site analysis method based on dynamic headspace GC-MS for analysis of five cyclic sulfur mustard degradation products that have previously been detected in sediments from chemical weapon dumping sites: 1,4-oxathiane, 1,3-dithiolane, 1,4-dithiane, 1,4,5-oxadithiephane, and 1,2,5-trithiephane. An experimental design involving authentic Baltic Sea sediments spiked with the target analytes was used to develop an optimized protocol for sample preparation, headspace extraction and analysis that afforded recoveries of up to 60-90%. The optimized method needs no organic solvents, uses only two grams of sediment on a dry weight basis and involves a unique sample presentation whereby sediment is spread uniformly as a thin layer inside the walls of a glass headspace vial. The method showed good linearity for analyte concentrations of 5-200 ng/g dw, good repeatability, and acceptable carry-over. The method's limits of detection for spiked sediment samples ranged from 2.5 to 11 μg/kg dw, with matrix interference being the main limiting factor. The instrumental detection limits were one to two orders of magnitude lower. Full-scan GC-MS analysis enabled the use of automated mass spectral deconvolution for rapid identification of target analytes. Using this approach, analytes could be identified in spiked sediment samples at concentrations down to 13-65 μg/kg dw. On-site validation experiments conducted aboard the research vessel R/V Oceania demonstrated the method's practical applicability, enabling the successful identification of four cyclic sulfur mustard degradation products at concentrations of 15-308μg/kg in sediments immediately after being collected near a wreck at the Bornholm Deep dumpsite in the Baltic Sea.

  7. Characterization of the Authenticity of Pasta di Gragnano Protected Geographical Indication Through Flavor Component Analysis by Gas Chromatography-Mass Spectrometry and Chemometric Tools.

    Science.gov (United States)

    Giannetti, Vanessa; Boccacci Mariani, Maurizio; Mannino, Paola

    2016-09-01

    An authentication study based on headspace solid-phase microextraction/GC-MS was performed with a set of 60 samples representative of traditional "Pasta di Gragnano protected geographical indication (PGI)" and the most common Italian pasta brands. Multivariate chemometric tools were used to classify the samples based on the chemical information provided from 20 target flavor compounds, including Maillard reaction and lipid oxidation products. Pattern recognition by principal component analysis and linear discriminant analysis showed a natural grouping of samples according to the drying process adopted for their production (i.e., the traditional Cirillo method versus a high-temperature approach). Subsequently, soft independent modeling by class analogy (SIMCA) and unequal dispersed classes (UNEQ) were used to build class models at 95% confidence and 100% sensitivity levels (forced models) for predictive classification purposes. The good performance obtained from the models in terms of cross-validation efficiency (SIMCA, 57.01%; UNEQ, 86.60%; 100% for both forced models) highlighted that targeted analysis of flavor profiles could be used to assess the authenticity of Pasta di Gragnano PGI samples. Hence, the proposed method may help to protect Pasta di Gragnano PGI from label frauds by verifying whether samples comply with statements concerning drying process conditions as stated in the product specification.

  8. Analysis of Serum Metabolic Profile by Ultra-performance Liquid Chromatography-mass Spectrometry for Biomarkers Discovery: Application in a Pilot Study to Discriminate Patients with Tuberculosis

    Directory of Open Access Journals (Sweden)

    Shuang Feng

    2015-01-01

    Full Text Available Background: Tuberculosis (TB is a chronic wasting inflammatory disease characterized by multisystem involvement, which can cause metabolic derangements in afflicted patients. Metabolic signatures have been exploited in the study of several diseases. However, the serum that is successfully used in TB diagnosis on the basis of metabolic profiling is not by much. Methods: Orthogonal partial least-squares discriminant analysis was capable of distinguishing TB patients from both healthy subjects and patients with conditions other than TB. Therefore, TB-specific metabolic profiling was established. Clusters of potential biomarkers for differentiating TB active from non-TB diseases were identified using Mann-Whitney U-test. Multiple logistic regression analysis of metabolites was calculated to determine the suitable biomarker group that allows the efficient differentiation of patients with TB active from the control subjects. Results: From among 271 participants, 12 metabolites were found to contribute to the distinction between the TB active group and the control groups. These metabolites were mainly involved in the metabolic pathways of the following three biomolecules: Fatty acids, amino acids, and lipids. The receiver operating characteristic curves of 3D, 7D, and 11D-phytanic acid, behenic acid, and threoninyl-γ-glutamate exhibited excellent efficiency with area under the curve (AUC values of 0.904 (95% confidence interval [CI]: 0863-0.944, 0.93 (95% CI: 0.893-0.966, and 0.964 (95% CI: 00.941-0.988, respectively. The largest and smallest resulting AUCs were 0.964 and 0.720, indicating that these biomarkers may be involved in the disease mechanisms. The combination of lysophosphatidylcholine (18:0, behenic acid, threoninyl-γ-glutamate, and presqualene diphosphate was used to represent the most suitable biomarker group for the differentiation of patients with TB active from the control subjects, with an AUC value of 0.991. Conclusion: The

  9. Metabolic Flux Analysis of Lipid Biosynthesis in the Yeast Yarrowia lipolytica Using 13C-Labled Glucose and Gas Chromatography-Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Huaiyuan Zhang

    Full Text Available The oleaginous yeast Yarrowia lipolytica has considerable potential for producing single cell oil, which can be converted to biodiesel, a sustainable alternative to fossil fuels. However, extensive fundamental and engineering efforts must be carried out before commercialized production become cost-effective. Therefore, in this study, metabolic flux analysis of Y. lipolytica was performed using 13C-labeled glucose as a sole carbon source in nitrogen sufficient and insufficient media. The nitrogen limited medium inhibited cell growth while promoting lipid accumulation (from 8.7% of their biomass to 14.3%. Metabolic flux analysis showed that flux through the pentose phosphate pathway was not significantly regulated by nitrogen concentration, suggesting that NADPH generation is not the limiting factor for lipid accumulation in Y. lipolytica. Furthermore, metabolic flux through malic enzyme was undetectable, confirming its non-regulatory role in lipid accumulation in this yeast. Nitrogen limitation significantly increased flux through ATP:citrate lyase (ACL, implying that ACL plays a key role in providing acetyl-CoA for lipid accumulation in Y. lipolytica.

  10. Metabolic Flux Analysis of Lipid Biosynthesis in the Yeast Yarrowia lipolytica Using 13C-Labled Glucose and Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Zhang, Huaiyuan; Wu, Chao; Wu, Qingyu; Dai, Junbiao; Song, Yuanda

    2016-01-01

    The oleaginous yeast Yarrowia lipolytica has considerable potential for producing single cell oil, which can be converted to biodiesel, a sustainable alternative to fossil fuels. However, extensive fundamental and engineering efforts must be carried out before commercialized production become cost-effective. Therefore, in this study, metabolic flux analysis of Y. lipolytica was performed using 13C-labeled glucose as a sole carbon source in nitrogen sufficient and insufficient media. The nitrogen limited medium inhibited cell growth while promoting lipid accumulation (from 8.7% of their biomass to 14.3%). Metabolic flux analysis showed that flux through the pentose phosphate pathway was not significantly regulated by nitrogen concentration, suggesting that NADPH generation is not the limiting factor for lipid accumulation in Y. lipolytica. Furthermore, metabolic flux through malic enzyme was undetectable, confirming its non-regulatory role in lipid accumulation in this yeast. Nitrogen limitation significantly increased flux through ATP:citrate lyase (ACL), implying that ACL plays a key role in providing acetyl-CoA for lipid accumulation in Y. lipolytica.

  11. Comparison of electrospray ionization and atmospheric pressure photoionization liquid chromatography mass spectrometry methods for analysis of ergot alkaloids from endophyte-infected sleepygrass (Achnatherum robustum).

    Science.gov (United States)

    Jarmusch, Alan K; Musso, Ashleigh M; Shymanovich, Tatsiana; Jarmusch, Scott A; Weavil, Miranda J; Lovin, Mary E; Ehrmann, Brandie M; Saari, Susanna; Nichols, David E; Faeth, Stanley H; Cech, Nadja B

    2016-01-05

    Ergot alkaloids are mycotoxins with an array of biological effects. With this study, we investigated for the first time the application of atmospheric pressure photoionization (APPI) as an ionization method for LC-MS analysis of ergot alkaloids, and compared its performance to that of the more established technique of electrospray ionization (ESI). Samples of the grass Achnatherum robustum infected with the ergot producing Epichloë fungus were extracted using cold methanol and subjected to reserved-phase HPLC-ESI-MS and HPLC-APPI-MS analysis. The ergot alkaloids ergonovine and lysergic acid amide were detected in these samples, and quantified via external calibration. Validation parameters were recorded in accordance with ICH guidelines. A triple quadrupole MS operated in multiple reaction monitoring yielded the lowest detection limits. The performance of APPI and ESI methods was comparable. Both methods were subject to very little matrix interference, with percent recoveries ranging from 82% to 100%. As determined with HPLC-APPI-MS quantification, lysergic acid amide and ergonovine were extracted from an A. robustum sample infected with the Epichloë fungus at concentrations of 1.143±0.051 ppm and 0.2822±0.0071 ppm, respectively. There was no statistically significant difference between these concentrations and those determined using ESI for the same samples.

  12. Analysis of sterols and fatty acids in natural and cultured Cordyceps by one-step derivatization followed with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, F Q; Feng, K; Zhao, J; Li, S P

    2009-07-12

    Ten free fatty acids namely lauric acid, myristic acid, pentadecanoic acid, palmitoleic acid, palmitic acid, linoleic acid, oleic acid, stearic acid, docosanoic acid and lignoceric acid and four free sterols including ergosterol, cholesterol, campesterol and beta-sitosterol in natural (wild) Cordyceps sinensis, Cordyceps liangshanensis and Cordyceps gunnii, as well as cultured C. sinensis and Cordyceps militaris were first determined using pressurized liquid extraction (PLE), trimethylsilyl (TMS) derivatization and GC-MS analysis. The conditions such as the amount of reagent, temperature and time for TMS derivatization of analytes were optimized. Under the optimum conditions, all calibration curves showed good linearity within the tested ranges. The intra- and inter-day variations for 14 investigated compounds were less than 3.4% and 5.2%, respectively. The results showed that palmitic acid, linoleic acid, oleic acid, stearic acid and ergosterol are main components in natural and cultured Cordyceps which could be discriminated by hierarchical clustering analysis based on the contents of 14 investigated compounds or the 4 fatty acids, where the contents of palmitic acid and oleic acid in natural Cordyceps are significantly higher than those in the cultured ones.

  13. Focused microwave-assisted extraction combined with solid-phase microextraction and gas chromatography-mass spectrometry for the selective analysis of cocaine from coca leaves.

    Science.gov (United States)

    Bieri, Stefan; Ilias, Yara; Bicchi, Carlo; Veuthey, Jean-Luc; Christen, Philippe

    2006-04-21

    An effective combination of focused microwave-assisted extraction (FMAE) with solid-phase microextraction (SPME) prior to gas chromatography (GC) is described for the selective extraction and quantitative analysis of cocaine from coca leaves (Erythroxylum coca). This approach required switching from an organic extraction solvent to an aqueous medium more compatible with SPME liquid sampling. SPME was performed in the direct immersion mode with a universal 100 microm polydimethylsiloxane (PDMS) coated fibre. Parameters influencing this extraction step, such as solution pH, sampling time and temperature are discussed. Furthermore, the overall extraction process takes into account the stability of cocaine in alkaline aqueous solutions at different temperatures. Cocaine degradation rate was determined by capillary electrophoresis using the short end injection procedure. In the selected extraction conditions, less than 5% of cocaine was degraded after 60 min. From a qualitative point of view, a significant gain in selectivity was obtained with the incorporation of SPME in the extraction procedure. As a consequence of SPME clean-up, shorter columns could be used and analysis time was reduced to 6 min compared to 35 min with conventional GC. Quantitative results led to a cocaine content of 0.70 +/- 0.04% in dry leaves (RSD <5%) which agreed with previous investigations.

  14. Multiresidue analysis of plant growth regulators in grapes by triple quadrupole and quadrupole-time of flight-based liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Oulkar, Dasharath P; Banerjee, Kaushik; Kulkarni, Sunil

    2011-01-01

    A selective and sensitive LC-MS/MS method is presented for simultaneous determination of 12 plant growth regulators, viz., indol-3-acetic acid, indol-3-butyric acid, kinetin, zeatin, 6-benzyl aminopurine, gibberellic acid, abscisic acid, chlormequat chloride, forchlorfenuron, paclobutrazole, daminozide, and 2,4-dichlorophenoxy acetic acid, in bud sprouts and grape berries. The sample preparation method involved extraction of homogenized sample (5 g) with 40 mL methanol (80%), and final determination was by LC-MS/MS in the multiple reaction monitoring (MRM) mode with time segmentation for quantification supported by complementary analysis by quadrupole-time of flight (Q-TOF) MS with targeted high-resolution MS/MS scanning for confirmatory identification based on accurate mass measurements. The recovery of the test compounds ranged within 90-107% with precision RSD less than 5% (n = 6). The method could be successfully applied in analyzing incurred residue samples, and the strength of accurate mass analysis could be utilized in identifying the compounds in cases where the qualifier MRM ions were absent or at an S/N less than 3:1 due to low concentrations.

  15. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations acetone+acetoacetate levels (~25 to 8300 µM) and D-ß-hydroxybutyrate levels (~30 to 16500 µM). Recovery values varied...

  16. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  17. Analysis of α,β,γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography--mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    SUN Tong-hua; FANG Neng-hu; ZHU Nan-wen; WANG Ya-lin; JIA Jin-ping

    2004-01-01

    A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were pressented. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, long lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water.

  18. A new gas chromatography/mass spectrometry method for the simultaneous analysis of target and non-target organic contaminants in waters.

    Science.gov (United States)

    Gómez, M J; Gómez-Ramos, M M; Agüera, A; Mezcua, M; Herrera, S; Fernández-Alba, A R

    2009-05-01

    In this study we developed a GC-MS method for the analysis of priority pollutants, personal care products (PCPs) and other emerging contaminants in waters using large volume injection with backflushing. Analyses are performed in the SIM/scan mode, so that in addition to the targeted organic contaminants, this method allows the simultaneous screening of non-target compounds. The scan data are analysed using Deconvolution Reporting Software (DRS) which screens the results for 934 organic contaminants. Deconvolution helps identify contaminants that are buried in the chromatogram by co-extracted materials and significantly reduces chromatographic resolution requirements, allowing shorter analysis times. All compounds have locked retention times and we can continually update and extend the mass spectral library including new compounds. Linearity and limits of detection in SIM and full-scan mode were studied. Method detection limits (MDLs) in effluent wastewater ranged in most of the cases from 1 to 36 ng/L in SIM mode and from 4 to 66 ng/L in full-scan mode; while in river water from 0.4 to 14 and 2-29 ng/L in SIM and full-scan mode, respectively. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to the screening of a large number of organic contaminants--not only to a subset of targets--in urban wastewaters from different wastewater treatment plants and also in river waters. Most of the target compounds were detected at concentration levels ranging from 11 to 8697 ng/L and from 7 to 1861 ng/L in effluent wastewater and river waters, respectively. Additionally, a group of 12 new compounds were automatically identified using the AMDIS and NIST libraries. Other compounds, such as the 4-amino musk xylene, a synthetic fragrance metabolite, which was not included in the databases, but has been manually searched in the full-scan chromatograms.

  19. Preparation of phenyl group-functionalized magnetic mesoporous silica microspheres for fast extraction and analysis of acetaldehyde in mainstream cigarette smoke by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, Danni; Sha, Yunfei; Zheng, Saijing; Liu, Baizhan; Deng, Chunhui

    2013-10-15

    Acetaldehyde is regarded as a toxic mainstream cigarette smoke constituent, and measurement of acetaldehyde in complex real samples is difficult owing to its high volatility and reactivity. In this work, phenyl group-functionalized magnetic mesoporous microspheres were developed as the solid-phase extraction sorbents for enrichment and analysis of acetaldehyde in mainstream cigarette smoke. The functional magnetic microspheres were first synthesized through a facile one-pot co-condensation approach. The prepared nanomaterials possessed abundant silanol groups in the exterior surface and numerous phenyl groups in the interior pore-walls, as well as a large surface area (273.5m(2)/g), strong superparamagnetism and uniform mesopores (3.3 nm). Acetaldehyde in mainstream cigarette smoke was collected in water and derivatizated with O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine. The formed acetaldehyde oximes were extracted and enriched by the prepared adsorbents via π-π interactions and subsequently analyzed using GC-MS. Extraction conditions such as amounts of sorbents, eluting solvent, adsorption and desorption time were investigated and optimized to achieve the best efficiency. Method validations including linearity, recovery, repeatability, and limit of detection were also studied. It was found that the suggested methodology provided low detection limit of 0.04 mg/mL, good recovery of 88-92%, intra-day and inter-day RSD values of 4.5% and 10.1%, and linear range of 0.25-4 mg/mL (R(2)=0.999). The results indicated that the proposed method based on phenyl-functionalized magnetic mesoporous microspheres was rapid, efficient and convenient for the enrichment and analysis of acetaldehyde in tobacco.

  20. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group-Update and Additions to the Determination of Chloroacetanilide Herbicide Degradation Compounds in Water Using High-Performance Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Lee, E.A.; Kish, J.L.; Zimmerman, L.R.; Thurman, E.

    2001-01-01

    An analytical method using high-performance liquid chromatography/mass spectrometry (HPLC/MS) was developed by the U.S. Geological Survey in 1999 for the analysis of selected chloroacetanilide herbicide degradation compounds in water. These compounds were acetochlor ethane sulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. The HPLC/MS method was updated in 2000, and the method detection limits were modified accordingly. Four other degradation compounds also were added to the list of compounds that can be analyzed using HPLC/MS; these compounds were dimethenamid ESA, dimethenamid OXA, flufenacet ESA, and flufenacet OXA. Except for flufenacet OXA, good precision and accuracy were demonstrated for the updated HPLC/MS method in buffered reagent water, surface water, and ground water. The mean HPLC/MS recoveries of the degradation compounds from water samples spiked at 0.20 and 1.0 ?g/L (microgram per liter) ranged from 75 to 114 percent, with relative standard deviations of 15.8 percent or less for all compounds except flufenacet OXA, which had relative standard deviations ranging from 11.3 to 48.9 percent. Method detection levels (MDL's) using the updated HPLC/MS method varied from 0.009 to 0.045 ?g/L, with the flufenacet OXA MDL at 0.072 ?g/L. The updated HPLC/MS method is valuable for acquiring information about the fate and transport of the parent chloroacetanilide herbicides in water.

  1. Age determination of ballpoint pen ink by thermal desorption and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Bügler, Jürgen H; Buchner, Hans; Dallmayer, Anton

    2008-07-01

    Two main approaches can be used for determining the age of an ink: indirect dating and direct dating. Indirect dating is based on the chemical analysis of an ink followed by comparison with known samples in a reference collection. The collection should contain information about the inks including the market introduction dates. This approach may allow for an anachronism to be detected. The second concept is based on measuring ink components that change with age. The analysis of solvents in ballpoint inks may be a useful parameter for determining the age of ink on paper. In a previous study, the authors demonstrated that thermal desorption of ink directly from paper, followed by chemical analysis using gas chromatography-mass spectrometry (GC-MS), is a promising procedure for characterizing ink-binder resins and solvents. Preliminary tests showed that monitoring the evaporation of ink solvent from ink on paper is not a suitable method for ink dating. Thermal analysis of ink on paper in two steps revealed that fresh ink releases a relative amount of solvent at a certain low temperature in a defined period of time, which decreases as the ink ages. As a consequence, this relative amount of solvent released at a certain low temperature, and its decrease with time, can be used to estimate ink age. This age-dependent parameter was studied in 85 different inks ranging in age from 1 week to 1.5 years. It was found that some inks showed a significant decrease of this parameter up to an age of several months, and that the aging process can be monitored within this period. For other inks, however, the age-dependent parameter decreases relatively fast, e.g., within a few days, to a constant level, which can be too fast for casework. Based on these results, a general procedure for assessing the age of ballpoint pen inks on paper was developed.

  2. The role of the acquisition methods in the analysis of natural and synthetic steroids and cholic acids by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Andrási, N; Helenkár, A; Vasanits-Zsigrai, A; Záray, Gy; Molnár-Perl, I

    2011-11-11

    An exhaustive GC-MS acquisition study was performed, for the simultaneous analysis of natural and synthetic steroids and cholic acids (in order to insert them into the last tierce of our multiresidue analysis system), such as androsterone, β-estradiol, transdehydroandro-sterone, transdehyroandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxyprogesterone-acetate, lithocholic acid, stigmasterol, cholic acid, chenodeoxycholic acid, β-sitosterol, ursodeoxycholic acid, 3-hydroxy-7-ketocholic acid and dehydrocholic acid, in total 26 compounds. As novelties to the field, for the trimethylsilyl (TMS) oxime ether/ester derivatives of steroids and cholic acids, at first, a tandem mass spectrometric (MS/MS), multiple reaction monitoring (MRM) type acquisition method has been developed in a single run; also for the first time, the three acquisition techniques, the full scan (FS), the selective ion monitoring (SIM), in our case the multiple ion monitoring (MIM) and the currently optimized MRM methods, have been compared; all three, in parallel, under strictly the same derivatization/instrumental conditions, both in matrix free solutions and municipal wastewater from two Hungarian wastewater treatment plants (WWTPs). Critical evaluation of the three acquisition protocols was collated on their analytical performances and validated under the same conditions. The data of six point calibration curves for FS, MIM and MRM methods, showed that both R² (0.9995, 0.9858, 0.9975) and RSD (5.3, 5.8, 5.0), for two parallel derivatizations, each injected three times, proved to be independent of the acquisition processes. Whereas, for the method limit of quantification (LOQ) and the instrument limit of quantification (ILQ) values showed considerable differences. LOQ data, were decreasing in the FS, MIM, MRM line (expressed in ng

  3. Gas chromatography - Mass spectrometry analysis and antibacterial activity of Cinnamomum burmanii essential oil to Staphylococcus aureus and Escherichia coli by gaseous contact

    Science.gov (United States)

    Chairunnisa, Tamhid, Hady Anshory; Nugraha, Arde Toga

    2017-03-01

    Infectious diseases and antibiotic resistance becomes a problem that must be resolved. Plant based products are among the alternative agents examined in order to replace conventional antibiotics. Cinnamaldehyde is one of the compound in cinnamon oil that has antibacterial activity. But the other compounds in cinnamon oil has also the potential antibacterial activity. The purpose of this study to conduct GC-MS analysis of cinnamon oil and its antibacterial activity to Staphylococcus aureus and Escherichia coli by gaseous contact. Cinnamomum burmannii was distilled by water-steam distillation to obtain essential oil. Identification of compounds was analyzed by GC-MS. Antibacterial activity was observed by gaseous contact method in airtight boxes. The GC-MS analyzed showed that there are four major compounds of cinnamon oil, trans-cinnamaldehyde (56,10%), 1,8-cineole (16,53%), α-pinene (3,44%) and α -terpineol (3,05%). The Minimum Inhibitory Dose (MID) of cinnamon oil to E. coli and S. aureus was 12.5 µL/L and 6.26 µL/L respectively. Gas compounds of cinnamon oil has more effective to gram-positive bacteria than gram-negative bacteria.

  4. Biological Fingerprinting Analysis of Interaction Between Taxoids in Taxus and Microtubule Protein by Microdialysis Coupled with High-performance Liquid Chromatography/Mass Spectrometry for Screening Antimicrotubule Agents

    Institute of Scientific and Technical Information of China (English)

    LEI Xiao-yuan; KONG Liang; SU Xing-ye; GUO Ming; ZOU Han-fa

    2008-01-01

    Some natural products,such as traditional Chinese medicines(TCMs),contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies,A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography(HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus)to microtubules is reported,It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis,and they were identified as the taxoids of taxol,baccatin Ⅲ,10-deacetylbaccatin Ⅲ(10-DAB),cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples,both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated,It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP,Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated.

  5. Development of a mixed-mode solid phase extraction method and further gas chromatography mass spectrometry for the analysis of 3-alkyl-2-methoxypyrazines in wine.

    Science.gov (United States)

    López, Ricardo; Gracia-Moreno, Elisa; Cacho, Juan; Ferrreira, Vicente

    2011-02-11

    A new method for analysing 3-isopropyl-2-methoxypyrazine, 3-sec-butyl-2-methoxypyrazine and 3-isobutyl-2-methoxypyrazine in wine has been developed and applied to wine. The analytes are extracted from 25 mL of wine in a solid-phase extraction cartridge filled with 60 mg of cation-exchange mixed-mode sorbent. Analytes are recovered with triethylamine in dichloromethane and the organic extract is analysed by GC-SIM-MS using 3-isopropyl-2-ethoxypyrazine as internal standard. The detection limits of the method are in all cases under 1 ng/L, below the olfactory thresholds of the compounds in wine. The repeatability of the method is around 15% for levels in wine of 2 ng/L. Linearity is satisfactory and recoveries are in all cases close to 100% with RSD between 13% and 20%. The method has been applied to the analysis of 12 Chilean white and 8 Spanish red wines. The levels found suggest that 3-alkyl-2-methoxypyrazines can exert a significant sensory contribution to the aroma of Chilean Sauvignon Blanc wines, while most likely they play a nearly negligible role on traditional Ribera and Rioja Spanish red wines.

  6. Comparative Analysis of the Volatile Components in the Fresh Roots and Rhizomes of Curcuma wenyujin by Static Headspace Gas Chromatography Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    FANG Fang; CHENG Zhi-Hong; GUO Yin-Long; CAI Yan-Ben

    2006-01-01

    Static headspace GC-MS method coupled with H/D exchange was firstly developed to determine and identify the volatile components in the fresh root and rhizome of Curcuma wenyujin. The TIC chromatograms of 3 batches of fresh roots harvested at different time showed significant difference in the volatile components: the constitution was the same but the content of them was different. More than 60 volatile components in fresh roots (Root of C.wenyujin) and rhizomes (Rhizome of C. wenyujin) of C. wenyujin were detected, of which 51 and 48 volatile components were identified respectively. The fresh roots and rhizomes of C. wenyujin were found to have the similar volatile components. The contents of these components were calibrated by the response of β-elemene. In addition,the principal active component, β-elemene, was further confirmed and relatively quantified by its standard.γ-terpinene showed obvious allylic hydrogen/deuterium exchange using deuterium oxide which gave a new method to identify some compounds containing allylic hydrogen. At the same time, the active hydrogen compounds were also further confirmed. The results show that HS-GC-MS method is a fast, simple and efficient way for the analysis of volatile components from medical plants.

  7. Gas chromatography-Mass spectrometry analysis and antibacterial activity of essential oil from aerial parts and roots of Anisomeles indica Linn

    Directory of Open Access Journals (Sweden)

    Ushir Yogesh

    2010-01-01

    Full Text Available The essential oil from the aerial part and roots of Anisomeles indica Linn. from the Toranmal forest, Maharashtra (India, was obtained by hydrodistillation after drying and grounding of the herbal material. A total of 27 components were resolved in the essential oil by GC-MS analysis, while 18 compounds were identified comparing the recorded mass spectra with the Nist 98/Nbs 75 K GC-MS library of mass spectra. The microbiological activity of the isolated essential oils was investigated as well. It was found that the essential oil shows microbiological activity on Escherichia coli, Pseudomonas aeruginosa, Bacillus pumilus and Staphylococcus aureus with a range of minimum inhibitory concentration values extended from 31.25 to 250 μg/ml. The percentage inhibition values calculated also support the minimum inhibitory concentration findings. The MBCs also performed for the same pathogens. Limonene, pinene, isobornyl acetate and eugenol can be considered as the main antimicrobial constituents in the essential oils of plants.

  8. Analysis of inherited metabolic disease in Beijing by gas chromatography-mass spectrometry%气相色谱-质谱法检测遗传代谢性疾病高危患儿

    Institute of Scientific and Technical Information of China (English)

    彭薇; 张万巧; 封志纯

    2014-01-01

    Objective To learn the incidence of the inherited metabolic diseases in Beijing. Methods Urine samples were analyzed by gas chromatography-mass spectrometry(GC-MS)for inherited metabolic diseases in high risky infants in Beijing . Results Urine samples from 411 high risky infants were analyzed by gas chromatography-mass spectrometry. 269 cases (65.5%) were detected to have metabolic abnormalities, including 19 cases (4.6%) diagnosed of inherited metabolic diseases in which there were 15 cases of methylmalonic academia and 1 case each of propionic academia, hyperphenylalaninemia, urea cycle abnormality and pyroglutamic aciduria. There were 22 suspected cases (5.4%) of inherited metabolic diseases including 13 cases of lactic acidosis, 5 cases of primary glycerol aciduria, 4 cases of fatty acid metabolic disorders including 1 case each of Citrin defects, tyrosinemia, galactosemia 3-methylcrotonoyl coenzyme A carboxylase deifciency and maple syrup urine disease. There were also 228 cases (55.5%) of metabolic abnormalities, such as increasing urine levels of lactic acid, sucrose,lactose, galactose, N-acetyl tyrosine, succinic acid, dicarboxylic acid and abnormal serine/threonine ratio. Conclusions Methylmalonic academia might be the most common inherited metabolic diseases in high risky infants in Beijing. For infants with clinical manifestations but unclear etiology, GC-MS should be performed. MS-MS and gene analysis could be combined if necessary.%目的:了解北京地区遗传性代谢性疾病(IMD)的发病情况。方法利用气相色谱-质谱法(GC-MS)对IMD高危儿进行尿液化学分析。结果411例IMD高危儿中检测出代谢异常269例(65.5%),其中确诊IMD 19例(4.6%),包括甲基丙二酸血症15例,丙酸血症、高苯丙氨酸血症、尿素循环异常和焦谷氨酸尿症各1例;疑似IMD 22例(5.4%),包括乳酸血症13例,原发性甘油尿症5例,脂肪酸代谢异常4例,Citrin缺陷症、酪氨

  9. Highly sensitive detection of melamine based on reversed phase liquid chromatography mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU QingQing; FAN KeXin; SHA Wei; RUAN HongQiang; ZENG Rong; SHIEH ChiaHui

    2009-01-01

    In this work, we developed a highly sensitive method to detect melamine based on reversed phase liquid chromatography mass spectrometry. A mass spectrometry compatible ion pair, heptafluorobu-tyric acid(HFBA), was used to separate melamine by reversed phase liquid chromatography prior to electrospray mass spectrometry. The incorporation of isotope internal standard and multiple reaction monitoring improved the accuracy and linearity of quantification. Based on this strategy, the method limit of quantification was 0.1 ng/g. The limits of quantification were 8 ng/g for liquid milk and 15 ng/g for dry milk powder. This method provided a reproducible and stable approach to sensitive detection and quantification of melamine.

  10. Evaluation of Antifungal and Antibacterial Activity and Analysis of Bioactive Phytochemical Compounds of Cinnamomum Zeylanicum (Cinnamon Bark using Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Imad Hadi Hameed

    2016-08-01

    Full Text Available Phytochemicals are chemical compounds often referred to as secondary metabolites. Thirty nine bioactive phytochemical compounds were identified in the methanolic extract of Cinnamon bark. The identification of phytochemical compounds is based on the peak area, retention time molecular weight and molecular formula. GC-MS analysis of Cinnamomum zeylanicum revealed the existence of the 6 -Oxa-bicyclo[3.1.0]hexan-3-one, Benzaldehyde, Cyclohexene,4-isopropenyl-1-methoxymethoxymethyl, Benzoic acid- methyl ester, Benzaldehyde dimethyl acetal, Benzenepropanal, Benzylidenemalonaldehyde, 3-Phenylpropanol, Cinnamaldehyde, (E, 2-Propen- 1- ol,3-phenyl, 9-Methoxybicyclo[6.1.0]nona – 2,4,6- triene , 1,3-Bis(cinnamoyloxymethyladamantine, Alfa.– Copaene, Naphthalene , 1,2,3,5,6,7,8,8a-octahydro-1,8a-dimethyl-7-(1-methyl, Cis – 2-Methoxycinnamic acid, Bicyclo[3.1.1]hept-2-ene,2,6- dimethyl-6-(4-methyl-3-pentenyl, Trans-2-Hydroxycinnamic acid , methyl ester, y-Muurolene, ß-Guaiene, Cadala-1(10,3,8-triene, Isolongifolene,4,5,9,10-dehydro, Cubenol, Tau-Muurolol, Α-Cadinol , Spiro[tricyclo[4.4.0.0(5.9]decane-10.2oxirane],1-methyl-4-isoprol, 6-Isopropenyl-4,8q-dimethyl-1,2,3,5,6,7,8,8a-octahydronaphthalen, Ethyl9,9-difomylnona-2,4,6,8-tetraenoate, Trans-13-Octadecenoic acid, Tributyl acetylcitrate, 9,12,15-Octadecatrienoic acid ,2,3-dihydroxypropyl ester, 9-Octadecenamide, 17.alfa.-21ß-28,30-Bisnorhopane, 17.alfa.-21ß-28,30-Bisnorhopane, Androstan-3-one,cyclic 1,2-ethanediyl mercaptole , (5α, (4H4a,5,6,7,8,8a-Hexahydrobenzopyran-5-one-3-carboxamide,2, 4H-Cyclopropa[5´,6´]benz [1´,2´,7,8]azuleno[5,6]oxiren-4-one,8,8a, (22S-21-Acetoxy-6α,11ß-dihydroxy-16α,17α-propylmethylenediox, (+-γ-Tocopherol,O-methyl and Stigmasterol. Cinnamomum zeylanicum contain chemical constitutions which may be useful for various herbal formulation as anti-inflammatory, analgesic, antipyretic, cardiac tonic and antiasthamatic. Cinnamomum zeylanicum was highly active against

  11. Extraction of pure components from overlapped signals in gas chromatography-mass spectrometry (GC-MS

    Directory of Open Access Journals (Sweden)

    Likić Vladimir A

    2009-10-01

    Full Text Available Abstract Gas chromatography-mass spectrometry (GC-MS is a widely used analytical technique for the identification and quantification of trace chemicals in complex mixtures. When complex samples are analyzed by GC-MS it is common to observe co-elution of two or more components, resulting in an overlap of signal peaks observed in the total ion chromatogram. In such situations manual signal analysis is often the most reliable means for the extraction of pure component signals; however, a systematic manual analysis over a number of samples is both tedious and prone to error. In the past 30 years a number of computational approaches were proposed to assist in the process of the extraction of pure signals from co-eluting GC-MS components. This includes empirical methods, comparison with library spectra, eigenvalue analysis, regression and others. However, to date no approach has been recognized as best, nor accepted as standard. This situation hampers general GC-MS capabilities, and in particular has implications for the development of robust, high-throughput GC-MS analytical protocols required in metabolic profiling and biomarker discovery. Here we first discuss the nature of GC-MS data, and then review some of the approaches proposed for the extraction of pure signals from co-eluting components. We summarize and classify different approaches to this problem, and examine why so many approaches proposed in the past have failed to live up to their full promise. Finally, we give some thoughts on the future developments in this field, and suggest that the progress in general computing capabilities attained in the past two decades has opened new horizons for tackling this important problem.

  12. [Determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Wang, Ghengyun; Zhang, Weiya; Li, Lixia; Shen, Yalei; Lin, Junfeng; Xie, Tangtang; Chu, Naiqing

    2014-08-01

    An effective method was established for the simultaneous determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry. Glycol ethers in leather and leather products were ultrasonically extracted at 45 °C, using ethyl acetate as the extraction solvent. The extracts were purified by solid phase extraction (SPE) columns, and then analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode. The content of each analyte was calibrated by external standard method. The limit of detection of ethylene glycol ethyl ether (EGEE) was 0. 10 mg/kg under the condition of signal to noise (S/N) of 3 and the limits of the other 11 glycol ethers were all less than 0.05 mg/kg. The spiked recoveries varied from 81. 2% to 95. 5% at three different spiked levels with the relative standard deviations (RSDs) ranged from 1.4% to 6. 6%. The proposed method is simple, rapid and accurate, with the limits of detection much less than the requirements of the Regulation Concerning Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) of European Union. It is applicable to the determination of residual glycol ethers in leather and leather products, and provides a reference for the relevant testing standards.

  13. Methods of analysis by the U. S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by graphitized carbon-based solid-phase extraction and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Anderson, Bruce D.; Werner, Stephen L.; Soliven, Paul P.; Coffey, Laura J.; Burkhardt, Mark R.

    2001-01-01

    In 1996, the U.S. Geological Survey National Water Quality Laboratory (NWQL) developed and implemented a graphitized carbon-based solid-phase extraction and high-performance liquid chromatographic analytical method to determine polar pesticide concentrations in surface- and ground-water samples. Subsequently, the NWQL developed a complementary analysis that uses high-performance liquid chromatography/mass spectrometry to detect, identify, and quantify polar pesticides and pesticide metabolites in filtered water at concentrations as low as 10 nanograms per liter. This new method was designed to improve sensitivity and selectivity over the prior method, and to reduce known interferences from natural organic matter. In this new method, pesticides are extracted from filtered water samples by useing a 0.5-gram graphitized carbon-based solid-phase extraction cartridge, eluted from the cartridge, and concentrations determined by using high-perforance liquid chromatography with elecrospray ionization-mass spectrometry. The upper concentratoin limit is 1.000 microgram per liter (ug/L) for most compounds. Single-operator method detection limits in organic-free water samples fortified with pesticdes at a concentration of 0.025 ug/L ranged from 0.0019 to 0.022 ug/L for all compunds in the method. The grand mean (mean of mean recoveries for individual compounds) recoveries in organic-free water samples ranged from 72 to 89 percent, fortified wit hpesticides at three concentrations between 0.025 and 0.5 ug/L. Grand mean recoveries in ground- and surface-water samples ranged from 46 to 119 percent, also fortified with pesticies at three concentrations between 0.025 and 0.5 ug/L. Long-term recoveries from reagent water spikes were used to demonstrate that 38 of 65 compounds can be reported without qualification of the quantitative result across the analytical range of the method. The remaining 27 are reported with qualified estimates of concentration because of greater variability

  14. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hu Song

    2012-01-01

    Full Text Available Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA. Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1 and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms.

  15. Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of bacteriochlorophylls from Chlorobiaceae: characteristic fragmentations.

    Science.gov (United States)

    Airs, Ruth L; Keely, Brendan J

    2002-01-01

    Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.

  16. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  17. Identification of Unknown Contaminants in Water Samples from ISS Employing Liquid Chromatography/Mass Spectrometry/Mass Spectrometry

    Science.gov (United States)

    Rutz, Jeffrey A.; Schultz, John R.

    2008-01-01

    Mass Spectrometry/Mass Spectrometry (MS/MS) is a powerful technique for identifying unknown organic compounds. For non-volatile or thermally unstable unknowns dissolved in liquids, liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) is often the variety of MS/MS used for the identification. One type of LC/MS/MS that is rapidly becoming popular is time-of-flight (TOF) mass spectrometry. This technique is now in use at the Johnson Space Center for identification of unknown nonvolatile organics in water samples from the space program. An example of the successful identification of one unknown is reviewed in detail in this paper. The advantages of time-of-flight instrumentation are demonstrated through this example as well as the strategy employed in using time-of-flight data to identify unknowns.

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by C-18 solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    Science.gov (United States)

    Zaugg, Steven D.; Sandstrom, Mark W.; Smith, Steven G.; Fehlberg, Kevin M.

    1995-01-01

    A method for the isolation of 41 pesticides and pesticide metabolites in natural-water samples using C-18 solid-phase extraction and determination by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction columns containing octadecyl-bonded porous silica to extract the pesticides. The columns are dried using carbon dioxide or nitrogen gas, and adsorbed pesticides are removed from the columns by elution with 3.0 milliliters of hexane-isopropanol (3:1). Extracted pesticides are determined by capillary- column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 4 micrograms per liter (g/L) for most pesticides, with the exception of widely used corn herbicides--atrazine, alachlor, cyanazine, and metolachlor--which have upper concentration limits of 20 g/L. Single- operator method detection limits in reagent-water samples range from 0.001 to 0.018 g/L. Average short-term single-operator precision in reagent- water samples is 7 percent at the 0.1- and 1.0-g/L levels and 8 percent at the 0.01-g/L level. Mean recoveries in reagent-water samples are 73 percent at the 0.1- and 1.0-g/L levels and 83 percent at the 0.01-g/L level. The estimated holding time for pesticides after extraction on the solid-phase extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time.

  19. Analysis of acrylonitrile, 1,3-butadiene, and related compounds in acrylonitrile-butadiene-styrene copolymers for kitchen utensils and children's toys by headspace gas chromatography/mass spectrometry.

    Science.gov (United States)

    Ohno, Hiroyuki; Kawamura, Yoko

    2010-01-01

    A headspace gas chromatography/mass spectrometry method was developed for the simultaneous determination of the residual levels of acrylonitrile (AN), 1,3-butadiene (1,3-BD), and their related compounds containing propionitrile (PN) and 4-vinyl-1-cyclohexene (4-VC) in acrylonitrile-butadiene-styrene (ABS) copolymers for kitchen utensils and children's toys. A sample was cut into small pieces, then N,N-dimethylacetamide and an internal standard were added in a sealed headspace vial. The vial was incubated for 1 h at 90 degrees C and the headspace gas was analyzed by gas chromatography/mass spectrometry. The recovery rates of the analytes were 93.3-101.8% and the coefficients of variation were 0.3-6.5%. In ABS copolymers, the levels were 0.3-50.4 microg/g for AN, ND-4.5 microg/g for PN, 0.06-1.58 microg/g for 1,3-BD, and 1.1-295 microg/g for 4-VC. The highest level was found for 4-VC, which is a dimer of 1,3-BD, and the next highest was for AN, which is one of the monomers of the ABS copolymer. Furthermore, the method was also applied to acrylonitrile-styrene (AS) copolymers and polystyrenes (PS) for kitchen utensils, and nitrile-butadiene rubber (NBR) gloves. In AS copolymers, AN and PN were detected at 16.8-54.5 and 0.8-6.9 microg/g, respectively. On the other hand, the levels in PS and NBR samples were all low.

  20. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    Science.gov (United States)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to

  1. Analysis of Odorants in Marking Fluid of Siberian Tiger (Panthera tigris altaica Using Simultaneous Sensory and Chemical Analysis with Headspace Solid-Phase Microextraction and Multidimensional Gas Chromatography-Mass Spectrometry-Olfactometry

    Directory of Open Access Journals (Sweden)

    Simone B. Soso

    2016-06-01

    Full Text Available Scent-marking is the most effective method of communication in the presence or absence of a signaler. These complex mixtures result in a multifaceted interaction triggered by the sense of smell. The objective was to identify volatile organic compound (VOC composition and odors emitted by total marking fluid (MF associated with Siberian tigers (Panthera tigris altaica. Siberian tiger, an endangered species, was chosen because its MF had never been analyzed. Solid phase microextraction (SPME for headspace volatile collection combined with multidimensional gas chromatography-mass spectrometry-olfactometry for simultaneous chemical and sensory analyses were used. Thirty-two VOCs emitted from MF were identified. 2-acetyl-1-pyrroline, the sole previously identified compound responsible for the “characteristic” odor of P. tigris MF, was identified along with two additional compounds confirmed with standards (urea, furfural and four tentatively identified compounds (3-methylbutanamine, (R-3-methylcyclopentanone, propanedioic acid, and 3-hydroxybutanal as being responsible for the characteristic aroma of Siberian tiger MF. Simultaneous chemical and sensory analyses improved characterization of scent-markings and identified compounds not previously reported in MF of other tiger species. This research will assist animal ecologists, behaviorists, and zookeepers in understanding how scents from specific MF compounds impact tiger and wildlife communication and improve management practices related to animal behavior. Simultaneous chemical and sensory analyses is applicable to unlocking scent-marking information for other species.

  2. Dansylation isotope labeling liquid chromatography mass spectrometry for parallel profiling of human urinary and fecal submetabolomes

    Energy Technology Data Exchange (ETDEWEB)

    Su, Xiaoling [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Wang, Nan [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Chen, Deying [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Lu, Yingfeng [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Huan, Tao [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Xu, Wei [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Li, Lanjuan, E-mail: ljli@zju.edu.cn [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China)

    2016-01-15

    Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on {sup 12}C-labeling of individual samples and {sup 13}C-labeling of a pooled urine or pooled feces and subsequent analysis of the {sup 13}C-/{sup 12}C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome

  3. The identification of synthetic organic pigments in modern paints and modern paintings using pyrolysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Russell, Joanna; Singer, Brian W; Perry, Justin J; Bacon, Anne

    2011-05-01

    A collection of more than 70 synthetic organic pigments were analysed using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We report on the analysis of diketo-pyrrolo-pyrrole, isoindolinone and perylene pigments which are classes not previously reported as being analysed by this technique. We also report on a number of azo pigments (2-naphthol, naphthol AS, arylide, diarylide, benzimidazolone and disazo condensation pigments) and phthalocyanine pigments, the Py-GC-MS analysis of which has not been previously reported. The members of each class were found to fragment in a consistent way and the pyrolysis products are reported. The technique was successfully applied to the analysis of paints used by the artist Francis Bacon (1909-1992), to simultaneously identify synthetic organic pigments and synthetic binding media in two samples of paint taken from Bacon's studio and micro-samples taken from three of his paintings and one painting attributed to him.

  4. Qualitative Gas Chromatography-Mass Spectrometry Analyses Using Amines as Chemical Ionization Reagent Gases

    Science.gov (United States)

    Little, James L.; Howard, Adam S.

    2013-12-01

    Ammonia is a very useful chemical ionization (CI) reagent gas for the qualitative analyses of compounds by positive ion gas chromatography-mass spectrometry (GCMS). The gas is readily available, inexpensive, and leaves no carbon contamination in the MS source. Compounds of interest to our laboratory typically yield abundant protonated or ammoniated species, which are indicative of a compound's molecular weight. Nevertheless, some labile compounds fragment extensively by substitution and elimination reactions and yield no molecular weight information. In these cases, a CI reagent gas mixture of methylamine in methane prepared dynamically was found to be very useful in obtaining molecular weight data. Likewise, deuterated ammonia and deuterated methylamine are useful CI reagent gases for determining the exchangeable protons in organic compounds. Deuterated methylamine CI reagent gas is conveniently prepared by dynamically mixing small amounts of methylamine with excess deuterated ammonia.

  5. Simultaneous determination of amphetamines and ketamines in urine by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Lin, Huei Ru; Lua, Ahai Chang

    2006-01-01

    A method for the simultaneous determination of amphetamines and ketamines (ketamine, norketamine and dehydronorketamine) in urine samples by gas chromatography/mass spectrometry was developed and validated. Urine samples were extracted with organic solvent and derivatized with trifluoroacetic anhydride (TFAA). The limits of detection and limits of quantification for each analyte were lower than 19 and 30 ng/mL, respectively. Within-day and between-day precisions were within 0.5% and 10.6%, respectively. Biases for three levels of control samples were within -10.6% and +7.8%. The concentration of dehydronorketamine was greater than those of ketamine or norketamine in 19 of 35 ketamine-positive samples. A group of 110 human urine samples previously determined to contain at least one of the target analytes was analyzed using the new method, and excellent agreement was observed with previous results.

  6. Current Applications of Liquid Chromatography/Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation

    Science.gov (United States)

    Ackermann, Bradley L.; Berna, Michael J.; Eckstein, James A.; Ott, Lee W.; Chaudhary, Ajai K.

    2008-07-01

    Current drug discovery involves a highly iterative process pertaining to three core disciplines: biology, chemistry, and drug disposition. For most pharmaceutical companies the path to a drug candidate comprises similar stages: target identification, biological screening, lead generation, lead optimization, and candidate selection. Over the past decade, the overall efficiency of drug discovery has been greatly improved by a single instrumental technique, liquid chromatography/mass spectrometry (LC/MS). Transformed by the commercial introduction of the atmospheric pressure ionization interface in the mid-1990s, LC/MS has expanded into almost every area of drug discovery. In many cases, drug discovery workflow has been changed owing to vastly improved efficiency. This review examines recent trends for these three core disciplines and presents seminal examples where LC/MS has altered the current approach to drug discovery.

  7. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dubbels, R.; Klenke, E.; Schnakenberg, E.; Ehlers, C.; Schloot, W. [Univ. of Bremen, Center of Human Genetics and Genetic Counselling, Bremen (Germany); Reiter, R.J. [The Univ. of Texas Health Science Center at San Antonio, Dept. of Cellular and Structural Biology, San Antonio, Texas (United States); Goebel, A.; Schiware, H.W. [Gemeinschaftslabor Dr. Schiwara et al., Breman (Germany)

    1995-01-01

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs.

  8. Simultaneous determination of steviol and steviol glycosides by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Shah, Romina; De Jager, Lowri S; Begley, Timothy H

    2012-01-01

    A direct, versatile method for the determination of steviol and nine steviol glycosides in food products has been developed by using electrospray ionisation liquid chromatography-mass spectrometry in the negative-ion mode. Ten stevia compounds were readily separated on an amino column by using a gradient separation. Data for analyte quantification were collected in the selected ion monitoring mode, giving the method limit of detection of 0.01-0.34 µg g⁻¹ and repeatability at the limit of quantitation of 2%-15% relative standard deviation. Thirty-four commercially available food products were tested by using the optimised method, and in these products rebaudioside A and stevioside comprised 52%-100% of the total steviol glycosides. Multiple reaction monitoring data were collected to provide analyte confirmation. Stability data for rebaudioside A stored at room temperature, 40°C and 60°C over a period of 1-14 days are shown.

  9. Solid-phase microcolumn extraction and gas chromatography-mass spectrometry identification of volatile organic compounds emitted by paper.

    Science.gov (United States)

    Hrivnák, Ján; Tölgyessy, Peter; Figedyová, Sona; Katuscák, Svetozár

    2009-11-15

    A rapid non-destructive sampling technique for the analysis of volatile organic compounds (VOCs) emitted by paper sheets is described. A capillary, which is connected to a microcolumn packed with Tenax TA, is inserted between two sheets at the centre of a paper stack encapsulated inside a PET/Al/PE composite foil. The other end of the microcolumn is connected to a gas-tight syringe and an appropriate volume of gaseous phase is aspirated. The microcolumn is then thermally desorbed in a modified GC inlet (modification is presented) and analysed by gas chromatography-mass spectrometry (GC-MS). In the chromatogram from the analysis of artificially aged paper sample 21 compounds were identified. Advantages of the method including the short sampling time (1 min), simplicity and economic aspect are discussed.

  10. Effect of ginseng polysaccharide on the urinary excretion of type 2 diabetic rats studied by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Niu, Jun; Pi, Zifeng; Yue, Hao; Wang, Yang; Yu, Qing; Liu, Shuying

    2012-10-15

    Ginseng polysaccharide is known to have anti-hyperglycemic and anti-hyperlipidemic effects in vivo and its precise mechanism of action is not clear. A urinary metabolomics method based on rapid-resolution liquid chromatography/mass spectrometry (RRLC/MS) was developed to investigate the effect of water-soluble ginseng polysaccharide (WGP) on type 2 diabetes in rats. Principal component analysis (PCA) was carried out for pattern recognition and a clear separation between type 2 diabetic rats and those treated with WGP was achieved. Eight potential biomarkers were found and identified. Significantly increased inosine, serotonin, phenylpropionylglycine and dodecanedioic acid showed the effect of WGP on purine metabolism, tryptophan metabolism, fatty acid metabolism and energy metabolism. 1-Methyladenine, 4-deoxyerythronic acid, 5-hydroxyhexanoic acid and tetrahydrocortisol were significantly decreased which indicated that WGP can regulate DNA metabolism, organic acids metabolism and steroid hormone metabolism. This work is helpful in the effect mechanism study of ginseng polysaccharide.

  11. Capillary ion chromatography-mass spectrometry for simultaneous determination of glucosylglycerol and sucrose in intracellular extracts of cyanobacteria.

    Science.gov (United States)

    Fa, Yun; Liang, Wenhui; Cui, He; Duan, Yangkai; Yang, Menglong; Gao, Jun; Liu, Huizhou

    2015-09-15

    A capillary ion chromatography-mass spectrometry (MS) method was proposed to determine glucosylglycerol (GG), sucrose, and five other carbohydrates. MS conditions and make-up flow parameters were optimized. This method is accurate and sensitive for simultaneous analysis of carbohydrates, with mean correlation coefficients of determination greater than 0.99, relative standard deviation of 0.91-2.81% for eight replicates, and average spiked recoveries of 97.3-104.9%. Limits of detection of sodium adduct were obtained with MS detection in selected ion mode for GG (0.006mg/L), sucrose (0.02mg/L), and other carbohydrates (0.03mg/L). This method was successfully applied to determine GG and sucrose in intracellular extracts of salt-stressed cyanobacteria.

  12. Headspace solid-phase microextraction for characterization of fragrances of lemon verbena (Aloysia triphylla) by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Nam-Sun; Lee, Dong-Sun

    2004-01-01

    Natural fragrances from lemon verbena (Aloysia triphylla) were studied by headspace solid phase microextraction (HS-SPME) techniques followed by gas chromatography-mass spectrometry (GC-MS), with six different fibre coatings being tested to evaluate the extraction efficiencies of several selected compounds. A total of 14 compounds were identified in the fragrances of lemon verbena. Geranial and neral were detected as major components and alpha-pinene, beta-pinene, beta-caryophyllene, and curcumene as minor components. Enantiomeric analysis of chiral compounds from lemon verbena was carried out on a chiral column. alpha-Pinene, limonene, and camphor in the fragrances emitted from lemon verbena were found in the (+), (-), and (-) forms, respectively.

  13. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Dang, N.A.; Mourão, M.; Kuijper, S.; Walters, E.; Janssen, H.-G.; Kolk, A.H.J.

    2015-01-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in b

  14. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared t

  15. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory method

  16. Environmental and biological determination of acrolein using new cold fiber solid phase microextraction with gas chromatography mass spectrometry.

    Science.gov (United States)

    Dias, Cláudia M; Menezes, Helvécio C; Cardeal, Zenilda L

    2017-04-01

    Acrolein is a pollutant released daily to the indoor environment from different sources. The present study reports the development of a simple and sensitive cold fiber solid phase microextraction sampling method for the determination of acrolein in exhaled air and indoor air by gas chromatography mass spectrometry. O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine was used as derivatizing agent supported on a 65-μm polydimethylsiloxane-divinylbenzene SPME fiber. An acrolein permeation tube at 326.25 ng min(-1) rate was used to generate gaseous standards. The method shows good results for main validation parameters. The limits of detection and quantification were 2.88 and 5.08 μg m(-3), respectively, for indoor analysis; and 2.40 and 3.79 μg m(-3), respectively, for exhaled air analysis. The precision showed standard deviation ranges from 6.00 to 8.00% for intra-assay analyses and from 8.00 to 10.00% for inter-assay analyses. After optimizing the conditions, analyses of real samples were performed on indoor environments contaminated by cigarette smoke, or heated oil, including pastry shops, restaurants, churros stands, and closed parking cars located in the city of Belo Horizonte, Brazil. Acrolein breaths of exposed people were also determined. A good Pearson correlation coefficient (r = 0.901) was observed between the concentration of acrolein in indoor air and exhaled air, allowing to propose acrolein breath as environmental exposure biomarker. Graphical Abstract Cold fiber solid phase microextraction gas chromatography/mass spectrometry.

  17. Different comparison analysis of lipstick and nail polish by microscopic spectrophotometry and gas chromatography-mass spectrometry%化妆品痕迹物证差异性的比对分析

    Institute of Scientific and Technical Information of China (English)

    吴国萍

    2014-01-01

    The comparison analysis of different lipstick and nail polish was studied by using microscopic spectrophotometry( MISP) and gas chromatography-mass spectrometry(GC-MS). Twenty-one similar color lipstick samples of different brands were collected from the same factory. Thirty nail polish of different factory were divided into three categories based on color. The MISP spectra were used for chromatic aberration calculation to distinguish the chromaticity of the samples. GC-MS were used for total ion chromato-grams to distinguish the component of the samples with similarΔE. GC-MS were used for structural formula and mass chromatogram of specified impurity to distinguish the component of the samples with similar ΔE and similar total ion chromatograms. 210 data of chromatic aberration(ΔE) between each pair of lipstick samples were obtained and only 5 samples whose chromaticities were less than 1. 5. 147 data of chromatic aberration(ΔE) between each pair of nail polish samples were obtained and only 6 samples whose chromaticities were less than 1. 5. It was found that similar ΔE was observed for samples with low similarity of total ion chromato-grams,while similar ΔE and similar total ion chromatograms were observed for samples with low similarity of structural formula and mass chromatogram of specified impurity. Thereby, the lipstick and nail polish can be identified according to the above informa-tions. It provided a new method for comparison analysis of different lipstick and nail polish.%本文以口红和指甲油为研究对象,共收集了21个同一品牌不同型号颜色相近的口红样本和30个三种颜色、不同品牌不同型号的指甲油样本。使用显微分光分光度计测定样本的色度数据并结合色度学理论计算色差;使用气质联用法对色差很小样本的总离子流图进行比对分析和结构解析,并进一步对总离子流图差异较小的样本选择邻苯二甲酸酯这类特定杂质结构

  18. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  19. Identification of novel circulating coffee metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Redeuil, Karine; Smarrito-Menozzi, Candice; Guy, Philippe; Rezzi, Serge; Dionisi, Fabiola; Williamson, Gary; Nagy, Kornél; Renouf, Mathieu

    2011-07-22

    This study reports a liquid chromatography-mass spectrometry method for the detection of polyphenol-derived metabolites in human plasma without enzymatic treatment after coffee consumption. Separation of available standards was achieved by reversed-phase ultra performance liquid chromatography and detection was performed by high resolution mass spectrometry in negative electrospray ionization mode. This analytical method was then applied for the identification and relative quantification of circulating coffee metabolites. A total of 34 coffee metabolites (mainly reduced, sulfated and methylated forms of caffeic acid, coumaric acid, caffeoylquinic acid and caffeoylquinic acid lactone) were identified based on mass accuracy (<4 ppm for most metabolites), specific fragmentation pattern and co-chromatography (when standard available). Among them, 19 circulating coffee metabolites were identified for the first time in human plasma such as feruloylquinic acid lactone, sulfated and glucuronidated forms of feruloylquinic acid lactone and sulfated forms of coumaric acid. Phenolic acid derivatives such as dihydroferulic acid, dihydroferulic acid 4'-O-sulfate, caffeic acid 3'-O-sulfate, dimethoxycinnamic acid, dihydrocaffeic acid and coumaric acid O-sulfate appeared to be the main metabolites circulating in human plasma after coffee consumption. The described method is a sensitive and reliable approach for the identification of coffee metabolites in biological fluids. In future, this analytical method will give more confidence in compound identification to provide a more comprehensive assessment of coffee polyphenol bioavailability studies in humans.

  20. Analysis of enantiomeric and non-enantiomeric monoterpenes in plant emissions using portable dynamic air sampling/solid-phase microextraction (PDAS-SPME) and chiral gas chromatography/mass spectrometry

    Science.gov (United States)

    Yassaa, Noureddine; Williams, Jonathan

    A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.

  1. Method of analysis and quality-assurance practices by the U.S. Geological Survey Organic Geochemistry Research Group; determination of geosmin and methylisoborneol in water using solid-phase microextraction and gas chromatography/mass spectrometry

    Science.gov (United States)

    Zimmerman, L.R.; Ziegler, A.C.; Thurman, E.M.

    2002-01-01

    A method for the determination of two common odor-causing compounds in water, geosmin and 2-methylisoborneol, was modified and verified by the U.S. Geological Survey's Organic Geochemistry Research Group in Lawrence, Kansas. The optimized method involves the extraction of odor-causing compounds from filtered water samples using a divinylbenzene-carboxen-polydimethylsiloxane cross-link coated solid-phase microextraction (SPME) fiber. Detection of the compounds is accomplished using capillary-column gas chromatography/mass spectrometry (GC/MS). Precision and accuracy were demonstrated using reagent-water, surface-water, and ground-water samples. The mean accuracies as percentages of the true compound concentrations from water samples spiked at 10 and 35 nanograms per liter ranged from 60 to 123 percent for geosmin and from 90 to 96 percent for 2-methylisoborneol. Method detection limits were 1.9 nanograms per liter for geosmin and 2.0 nanograms per liter for 2-methylisoborneol in 45-milliliter samples. Typically, concentrations of 30 and 10 nanograms per liter of geosmin and 2-methylisoborneol, respectively, can be detected by the general public. The calibration range for the method is equivalent to concentrations from 5 to 100 nanograms per liter without dilution. The method is valuable for acquiring information about the production and fate of these odor-causing compounds in water.

  2. Analysis of Common Volatile Components in Different Batchs of Saffron by Gas Chromatography-Mass Spectrometry%藏红花挥发油共有组分的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    隋吴彬

    2011-01-01

    The volatile components in saffron were detected by gas chromatography-mass spectrometry to compare the volatile components and contents in different batches of saffron from the same origin. The relative contents of each component were determined by peak area normalization, and the volatile components variation of different batches of saffron was investigated. As a result, 42 components were identified and certain similarity has been found in different batches of saffron from the same origin.%本文采用气相色谱-质谱(GC-MS)法分析不同批次的藏红花挥发性成分,探讨同一产地不同批次藏红花挥发组分的成分与含量,并用峰面积归一化法确定各成分的相对含量,以其中的主要挥发组分作为考察指标,观察不同批次藏红花挥发组分的变化情况.初步鉴定出42种成分,且同一产地不同批次藏红花挥发性成分具有一定相似性.

  3. Analysis and Determmination of Fatty Acid in Donkey Milk Powder by Gas Chromatography - Mass Spectrometry%气质联用技术分析测定驴奶粉中脂肪酸

    Institute of Scientific and Technical Information of China (English)

    钱宗耀; 刘河疆; 王建梅; 周晓龙

    2012-01-01

    [Method]The aim was to analyze and determine the chemical constituents and contents of fatty acid in donkey milk powder.[Method]The chemical constituents of donkey milk powder fatty acid was analyzed and determined by gas chromatography-mass spectrometry technique.[Result]There are thirty fatty acids in donkey milk powder,among which the content of unsaturated fatty acid reaches 60.0%.[Conclusion]The study provides references for the rapid and accurate determination of fatty acid contents in milk powder,and the further development of donkey milk powder prodocts.%[目的]分析测定驴奶粉中的脂肪酸类化学成分和含量.[方法]采用气相色谱-质谱联用技术对驴奶粉中全部脂肪酸的化学成分进行分析与测定.[结果]驴奶粉中含有30多种脂肪酸,其中不饱和脂肪酸约占总脂肪酸含量的60%.[结论]该研究可为快速、准确测定奶粉中脂肪酸含量和进一步开发驴奶粉产品提供参考.

  4. Analysis of MC-LR and MC-RR in tissue from freshwater fish (Tinca tinca) and crayfish (Procambarus clarkii) in tench ponds (Cáceres, Spain) by liquid chromatography-mass spectrometry (LC-MS).

    Science.gov (United States)

    Ríos, Victoria; Moreno, Isabel; Prieto, Ana I; Puerto, María; Gutiérrez-Praena, Daniel; Soria-Díaz, Ma Eugenia; Cameán, Ana M

    2013-07-01

    In the present study a new method has been developed and validated for detecting free microcystins (MCs) (MC-RR, MC-LR and MC-YR) by liquid chromatography-mass spectrometry (LC-MS) in the cyprinid Tinca tinca and in the crayfish Procambarus clarkii collected from three ponds in Extremadura (Spain) where the presence of the cyanobacteria species Microcystis aeruginosa and Anabaena spiroides has been confirmed. Once the method had been validated, free MCs were determined in fish (tench, T. tinca) and crayfish from different ponds in order to understand how they are bioaccumulated through the food web. MCs were not detected in any of the fish samples analyzed. It was confirmed that P. clarkii accumulated MCs in their tissues without losing their organoleptic characteristics, with MC-LR (2.3-18.1 μg MC-LR/g body weight) being the predominant MC variant detected in all the crayfish samples. MC-RR was measured in 50% of the samples analyzed, ranging between 1.4 and 7.8 μg MC-RR/g body weight and no MC-YR was detected. The results indicated that crayfish can accumulate free MCs in higher quantities than tench that live in ponds contaminated by toxic cyanobacteria species, and emphasized the need for regular monitoring if the health risks associated with their consumption are to be avoided.

  5. Analysis of the Volatile Components in Peel Oil of Yuzu byGas Chromatography/Mass Spectrometry%柚子果皮油挥发性成分的气相色谱-质谱分析

    Institute of Scientific and Technical Information of China (English)

    杨荣华

    2001-01-01

    采用溶剂萃取法提取柚子果皮的精油,经气相色谱和质谱联机分析,同时依据各成分的保留指数,鉴定出71种挥发性物质,其中有21种碳氢化合物,50种含氧化合物。在碳氢化合物中以柠烯、γ-萜品烯为主要成分;而在含氧化合物中主要是沉香醇、α-萜品醇、百里酚以及一些脂肪族醛。%The essential oil of Yuzu was extracted from the peel by solvent extraction, and analyzed by combined capillary gas chromatography/mass spectrometry and retention indices. Among 71 identified compounds, there were 21 hydrocarbons which were mainly limonene and γ-terpinene, and 50 oxygenated compounds in representative of linalool, α-terpineol, thymol and aliphatic aldehydes.

  6. Adulteration and Quality Analysis of Olive Oil by Near-Infrared Spectrometry and Gas Chromatography-Mass Spectrometry%近红外光谱和气相色谱-质谱联用技术对橄榄油掺杂及品质分析研究

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    分别采用近红外光谱技术及气相色谱-质谱联用技术对橄榄油样品进行分析。采用透射方式采集橄榄油样品的近红外光谱比漫反射方式可以获得更好的重现性;通过直观分析、二阶求导以及主成分分析可快速判别橄榄油与掺杂橄榄油。0.10 g橄榄油样品经过10 mL的KOH-甲醇溶液甲酯化处理后,加入10 mL正己烷和10 mL水进行液液萃取,并对正己烷提取液进行气相色谱-质谱分析,对39种橄榄油脂肪酸甲酯含量的分析结果与近红外光谱的主成分分析图对比得出,油酸和亚油酸是影响橄榄油近红外光谱扫描结果的主要成分。%Olive oil was analyzed by near-infrared spectrometry and gas chromatography-mass spectrometry.The reproducibility of near-infrared spectrum acquired through transmission is better than that acquired through diffuse reflection.The adulteration of olive oil was differentiated rapidly by visual analysis,derivation of two order analysis and principal component analysis(PCA).0.10 g of olive oil was added 10 mL of KOH-methanol to methyl-etherification.Then 10 mL of n-hexane and 10 mL of water were added to liquid-liquid extraction.The extracts of n-hexane were analyzed by gas chromatography-mass spectrometry and the fatty acid methyl ester(FAME) of 39 olive oil samples were compared with the PCA of near-infrared spectrometry.The results indicated that oleic acid and linoleic acid were major impact components to the near-infrared spectrums of olive oil.

  7. Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) in toxicological analysis. Studies on the detection of clobenzorex and its metabolites within a systematic toxicological analysis procedure by GC-MS and by immunoassay and studies on the detection of alpha- and beta-amanitin in urine by atmospheric pressure ionization electrospray LC-MS.

    Science.gov (United States)

    Maurer, H H; Kraemer, T; Ledvinka, O; Schmitt, C J; Weber, A A

    1997-02-07

    GC-MS is the method of choice for toxicological analysis of toxicants volatile in GC while non-volatile and/or thermally labile toxicants need LC-MS for their determination. Studies are presented on the toxicological detection of the amphetamine-like anorectic clobenzorex in urine by GC-MS after acid hydrolysis, extraction and acetylation and by fluorescence polarization immunoassay (FPIA, TDx (meth)amphetamine II). After ingestion of 60 mg of clobenzorex, the parent compound and/or its metabolites could be detected by GC-MS for up to 84 h or by FPIA for up to 60 h. Since clobenzorex shows no cross-reactivity with the used immunoassay, the N-dealkylated metabolite amphetamine is responsible for the positive TDx results. The intake of clobenzorex instead of amphetamine can be differentiated by GC-MS detection of hydroxyclobenzorex which is detectable for at least as long as amphetamine. In addition, the described GC-MS procedure allows the simultaneous detection of most of the toxicologically relevant drugs. Furthermore, studies are described on the atmospheric pressure ionization electrospray LC-MS detection of alpha- and beta-amanitin, toxic peptides of amanita mushrooms, in urine after solid-phase extraction on RP-18 columns. Using the single ion monitoring mode with the ions m/z 919 and 920 the amanitins could be detected down to 10 ng/ml of urine which allows us to diagnose intoxications with amanita mushrooms.

  8. Discriminating Hodgdon Pyrodex(®) and Triple Seven(®) using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Routon, Benjamin J; Kocher, Brandon B; Goodpaster, John V

    2011-01-01

    Pyrodex(®) and Triple Seven(®) are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex(®) contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven(®) lacks sulfur but also contains 3-nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography-mass spectrometry. Each derivative was clearly resolved from other components, and high-quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.

  9. Determination of free and ethoxylated alkylphenols in leather with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ma, He-Wei; Cheng, Ya

    2010-12-10

    An analytical approach was developed to determine nonylphenol (NP), octylphenol (OP), nonylphenol ethoxylates (NPEO(n)) and octylphenol ethoxylates (OPEO(n)) in leather samples involving the conversion of NPEO(n) and OPEO(n) into the corresponding NP and OP. The four targets were extracted from samples using ultrasonic-assisted acetonitrile extraction. NP and OP in the extracts were directly isolated with hexane and quantitatively determined with 4-n-nonylphenol as internal standard by gas chromatography-mass spectrometry (GC-MS). For NPEO(n) and OPEO(n) in the extracts, they were first converted into NP and OP with aluminum triiodide as cleavage agent, and the yielded NP and OP were determined by GC-MS. The contents of NPEO(n) and OPEO(n) were calculated by normalizing to NPEO(9) and OPEO(9), respectively. This method was properly validated and the real sample tests revealed the pollution significance of leather by NPEO(n) and OPEO(n).

  10. Saccharomyces cerevisiae oxidative response evaluation by cyclic voltammetry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Castro, Cristiana C; Gunning, Caitriona; Oliveira, Carla M; Couto, José A; Teixeira, José A; Martins, Rui C; Ferreira, António C Silva

    2012-07-25

    This study is focused on the evaluation of the impact of Saccharomyces cerevisiae metabolism in the profile of compounds with antioxidant capacity in a synthetic wine during fermentation. A bioanalytical pipeline, which allows for biological systems fingerprinting and sample classification by combining electrochemical features with biochemical background, is proposed. To achieve this objective, alcoholic fermentations of a minimal medium supplemented with phenolic acids were evaluated daily during 11 days, for electrochemical profile, phenolic acids, and the volatile fermentation fraction, using cyclic voltametry, high-performance liquid chromatography-diode array detection, and headspace/solid-phase microextraction/gas chromatography-mass spectrometry (target and nontarget approaches), respectively. It was found that acetic acid, 2-phenylethanol, and isoamyl acetate are compounds with a significative contribution for samples metabolic variability, and the electrochemical features demonstrated redox-potential changes throughout the alcoholic fermentations, showing at the end a similar pattern to normal wines. Moreover, S. cerevisiae had the capacity of producing chlorogenic acid in the supplemented medium fermentation from simple precursors present in the minimal medium.

  11. Gas chromatography-mass spectrometry profiles of urinary organic acids in healthy captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Tordiffe, Adrian Stephen Wolferstan; van Reenen, Mari; Reyers, Fred; Mienie, Lodewyk Jacobus

    2017-04-01

    In captivity, cheetahs (Acinonyx jubatus) frequently suffer from several unusual chronic diseases that rarely occur in their free-ranging counterparts. In order to develop a better understanding of their metabolism and health we documented the urine organic acids of 41 apparently healthy captive cheetahs, in an untargeted metabolomic study, using gas chromatography-mass spectrometry. A total of 339 organic acids were detected and annotated. Phenolic compounds, thought to be produced by the anaerobic fermentation of aromatic amino acids in the distal colon, as well as their corresponding glycine conjugates, were present in high concentrations. The most abundant organic acids in the cheetahs' urine were an as yet unidentified compound and a novel cadaverine metabolite, tentatively identified as N(1),N(5)-dimethylpentane-1,5-diamine. Pantothenic acid and citramalic acid concentrations correlated negatively with age, while glutaric acid concentrations correlated positively with age, suggesting possible dysregulation of coenzyme A metabolism in older cheetahs. This study provides a baseline of urine organic acid reference values in captive cheetahs and suggests important avenues for future research in this species.

  12. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  13. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  14. Determination of ortho-phenylphenol in human urine by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Bartels, M J; Brzak, K A; Bormett, G A

    1997-12-05

    A sensitive gas chromatographic-mass spectrometric method was developed to quantitate total o-phenylphenol (OPP) (free plus conjugates) in human urine. Conjugates of OPP were acid-hydrolyzed to free OPP, derivatized to the pentafluorobenzoyl ester derivative and analyzed via negative-ion chemical ionization gas chromatography-mass spectrometry. Two stable isotope analogs of OPP were shown to be suitable as internal standards for this method (D2-phenol ring, 13C6-phenyl ring). A synthetic method is presented for the preparation of the D2-OPP internal standard. The 13C6-OPP analog was also shown to be useful as an alternate test material for laboratory-based exposure studies. The limit of quantitation for this method was 1 ng OPP/ml urine. Calibration curves were linear for the analyte over the concentration range of 0.5-1117 ng OPP/ml urine. Relative recovery of OPP from urine ranged from 97.0 to 104.7%. Low levels of OPP (mean=6+/-7 ng/ml; n=22) were found in control human urine samples. The method was validated with urine samples obtained from human volunteers undergoing a dermal exposure study with 12C-/13C6-/14C-OPP. This method was developed to aid in assessments of human exposure to OPP during a variety of uses of the compound.

  15. [Determination of acrylamide in foods by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Shen, Weijian; Shen, Chongyu; Zhao, Zengyun; Chen, Huilan; Xu, Jinzhong

    2006-11-01

    A confirmatory method is presented for the determination of acrylamide in different food products by gas chromatography-mass spectrometry (GC-MS). The method is based on the extraction of acrylamide with and methanol, and purification with Carrez I zinc sulfate) and Carrez II (potassium hexacyanoferrate) solution, followed by bromination onto the acrylamide double bond. The derivative was extracted with ethyl acetate/hexane (4: 1, v/v), and converted to the stable 2-bromopropenamide by dehydrobromination using 10% triethylamine, then analyzed by GC-MS, employing 13C3-acrylamide as internal standard. In-house validation data for flour and bread showed good accuracy and precision of the method. The recoveries of acrylamide in the French fries and bread were all in the range from 80% to 110% after correction of analyte loss by the internal standard at three spike levels of 0.02, 0.05 and 0.2 mg/kg, and relative standard deviations (RSDs) no more than 12.7%. The limits of detection for flour and bread were estimated at 5 microg/kg.

  16. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  17. Determination of Menthol in Plasma and Urine by Gas Chromatography/Mass Spectrometry (GC/MS).

    Science.gov (United States)

    Peat, Judy; Frazee, Clint; Kearns, Gregory; Garg, Uttam

    2016-01-01

    Menthol, a monoterpene, is a principal component of peppermint oil and is used extensively in consumer products as a flavoring aid. It is also commonly used medicinally as a topical skin coolant; to treat inflammation of the mucous membranes, digestive problems, and irritable bowel syndrome (IBS); and in preventing spasms during endoscopy and for its spasmolytic effect on the smooth muscle of the gastrointestinal tract. Menthol has a half life of 3-6 h and is rapidly metabolized to menthol glucuronide which is detectable in urine and serum following menthol use. We describe a method for the determination of total menthol in human plasma and urine using liquid/liquid extraction, gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode and menthol-d4 as the internal standard. Controls are prepared with menthol glucuronide and all samples undergo enzymatic hydrolysis for the quantification of total menthol. The method has a linear range of 5-1000 ng/mL, and coefficient of variation <10%.

  18. Determination of terpenes in tequila by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Capella, Santiago; Juárez, Rocío; Labastida, Carmen

    2006-11-17

    Solid phase microextraction and capillary gas chromatography-mass spectrometry were used for the determination of seven terpenes in tequila. The method was selected based on the following parameters: coating selection (PA, PDMS, CW/DVB, and PDMS/DVB), extraction temperature, addition of salt, and extraction time profile. The extraction conditions were: PDMS/DVB fiber, Headspace, 100% NaCl, 25 degrees C extraction temperature, 30 min extraction time and stirring at 1200 rpm. The calibration curves (50-1000 ng/ml) for the terpenes followed linear relationships with correlation coefficients (r) greater than 0.99, except for trans,trans-farnesol (r = 0.98). RSD values were smaller than 10% confirmed that the technique was precise. Samples from 18 different trade brands of "Aged" tequila analyzed with the developed method showed the same terpenes in different concentrations. The analytical procedure used is selective, robust (more than 100 analyses with the same fiber), fast and of low-cost.

  19. Determination of phthalate esters in teas and tea infusions by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Liping; Ma, Lijuan; Qiao, Yang; Lu, Yan; Xiao, Dongguang

    2016-04-15

    Phthalate esters (PAEs), a group of environmental pollutants which are carcinogenic to human body, have been detected in teas. In this work, five PAEs in teas and tea infusions were quantitatively determined by a modified simultaneous distillation extraction (SDE) coupled with gas chromatography-mass spectrometry. After the optimization of SDE, the proposed method afforded a wide range of linearity and high linear regression coefficients with the limits of detection range of 0.24-3.72 μg/kg. The average recoveries were 79.83-116.67% for tea samples and 78.22-101.64% for tea infusions with all the relative standard deviations below 20%. The total content of five PAEs in teas was 1.135-3.734 mg/kg and the total dissolving ratio of five PAEs from tea to infusion was 19.05-28.07% for the selected tea samples. The risk assessment result of all the selected tea samples demonstrated that the population with the habit of drinking tea won't cause risk to human health.

  20. Bioassay- and liquid chromatography/mass spectrometry-guided acetylcholinesterase inhibitors from Picriafel-terrae

    Directory of Open Access Journals (Sweden)

    Lu Wen

    2013-01-01

    Full Text Available Background: Picria fel-terrae is a traditional Chinese medicine. Materials and Methods: A new approach to the search for acetylcholinesterase (AChE inhibitors from Picria fel-terrae is presented. Results: Bioassay- and LC-MS-guided fractionation of the ethyl acetate extract was from traditional Chinese medicine P.fel-terrae. Following primary extraction, the ethyl acetate extracts fraction of P.fel-terrae showed strong AChE inhibitory activities. So the sample was separated using highperformance liquid chromatography (HPLC. The effluent was split towards two identical 96-well fraction collectors, and the presence of the biologically interesting portion and chromatographic fractions could be readily detected by analyzing selected ion chromatograms through an electrophoresis-electrospray ionization mass spectrometry (ESIMS system for accurate mass measurement. One 96-well plate was used for a bioassay (AChE-inhibitory assay and detected the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate was used for identification by LC-(+ ESIMS. Conclusion: As abovementioned, the AChE inhibitory constituents from P.fel-terrae by LC-bioassay-ESIMS were rapid identified. Liquid chromatography/ mass spectrometry (LC-MS screening detected the presence of six active compounds, identified as picfeltarraenin IA (1, picfeltarraenin IB (2, picfeltarraenin IV (3, picfeltarraenin X (4, picfeltarraenin XI (5, and one unknown compound. The structures were further determined by 13C NMR. The six compounds expressed stronger AChE inhibition than the known AChE inhibitorTacrine. Above all, the value of this LC-bioassay-ESIMS methodology is highlighted by the finding and structure elucidation of the active constituents from many other structural families of natural products.

  1. Analysis of the Volatile Organic Components in Malus hupenhensis Rehd Leaves by Direct Thermal Desorption Gas Chromatography-mass Spectrometry%湖北海棠叶挥发性成分的 DTD-GC/MS 分析∗

    Institute of Scientific and Technical Information of China (English)

    王宵; 杜业云; 杨志斌; 李晖; 杨柳

    2015-01-01

    The method of direct thermal desorption (DTD)combed with gas chromatography-mass spectrometry (GC/MS)was applied to analyze the volatile organic components in leaves of Malus hupenhensis for the first time,and 46 kinds of volatile organic components were identified.The main chemical components were hydrocarbons,esters,alcohols,ke-tones,vinyl,aldehydes and so on.8 kinds of components can be used as spice additives,5 types can be used for medical purposes,2 kinds can be used as insecticides.This method of analyzing Malus hupenhensis leaves components had good re-peatability,and was simple,efficient,sensitive and environment-friendly.%采用直接热脱附—气相色谱/质谱联用技术(DTD-GC/MS)首次分析了湖北海棠叶挥发性成分,共检测鉴定出有效成分46种,主要包括烷烃类、酯类、醇类、酮类、烯类、醛类等化合物。其中,8种可用作香料添加剂,5种可作医疗用途,2种可用于杀虫剂。采用直接热脱附—气相色谱/质谱法分析湖北海棠叶挥发成分重现性好、操作简单、效率高、绿色环保。

  2. Simultaneous extraction and clean-up of polybrominated diphenyl ethers and polychlorinated biphenyls from sheep liver tissue by selective pressurized liquid extraction and analysis by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Zulin; Ohiozebau, Ehimai; Rhind, Stewart M

    2011-02-25

    We describe a selective pressurized liquid extraction (SPLE) method, followed by gas chromatography-mass spectrometry (GC-MS), for the simultaneous extraction and clean-up of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep liver tissue samples. The on-line clean-up of liver tissue by SPLE was tested using differing amount of acid-modified silica (sulphuric acid:silica gel, 1:2, w/w), the most effective amount being 20 g. Different extraction solvents (iso-hexane and dichloromethane), either alone or in various combinations, were used to extract these target compounds from spiked liver samples. Variables affecting the SPLE extraction efficiency, including temperature, pressure, number of extraction cycles and static extraction time were studied; the optimum parameters were 80 °C, 10.3 MPa, 2 cycles and 5 min, respectively. The SPLE based method was compared with more traditional Soxhlet, off-line PLE, ultrasonic and heating extraction methods. Overall the mean percentage recoveries for all target chemicals using SPLE were 86-103% (n=3, SD extraction methods. The limits of detection of the proposed method were 5-96 pg g⁻¹ and 2-29 pg g⁻¹ for the different PBDE and PCB chemicals studied, respectively. The outputs of the proposed method were linear over the range from 0.02 to 30 ng g⁻¹, for all PCB and PBDE congeners except for PBDE 100 and 153 (0.05-30 ng g⁻¹) and PBDE 183 (0.1-30 ng g⁻¹). The method was successfully applied to sheep liver samples for the determination of the target PBDE and PCB compounds.

  3. Analysis of nicotine solution of electronic cigarette by pyrolysis-gas chromatography mass spectrometry%热裂解气相色谱质谱检测电子烟烟碱液

    Institute of Scientific and Technical Information of China (English)

    张伟童; 王小伍

    2014-01-01

    在电子烟烟碱液未经预处理以及经历在空气中多次蒸馏预处理两种条件下,采用热裂解气相色谱质谱(Py-GCMS)检测了电子烟烟碱液组分变化情况。未经预处理进行Py-GCMS时,由于烟碱液气化时与空气隔绝,气体组分的物质类型稳定,包含丙二醇、丙三醇和尼古丁,尼古丁含量低于10%;经历高温下空气中反复蒸馏预处理的烟碱液,气化后组分的物质类型和比例都与预处理的温度有关,蒸馏温度160℃时,尼古丁含量达到了21.07%。%Pyrolysis-Gas chromatography mass spectrometry method is used to analyze the relation between temperature and component and content of nicotine solution of electronic cigarette at two situations, namely without pretreatment on nicotine solution and after nicotine solution being evaporated five times in the air at set temperature. For the former situation, nicotine solution shows stable components, Propylene Glycol, Glycerin and nicotine, in which the content of nicotine is always lower than 10%. This is because nicotine solution is isolated from air when evaporating. For the latter situation, the component and content all change with evaporating temperature. When evaporating temperature is 160 ℃, the content of nicotine comes to 21.07%.

  4. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Wastewater Compounds by Polystyrene-Divinylbenzene Solid-Phase Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.; Barber, Larry B.; Burkhardt, Mark R.

    2002-01-01

    A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides. Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent ? 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  6. 气相色谱/质谱法分析长白山脉松茸中的脂肪酸%Analysis of fatty acid content in Changbai mountains Tricholoma matsutake sing by gas chromatography/mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    南京熙; 高明; 孙佳; 李官浩; 金炯国

    2012-01-01

    建立了长白山脉松茸中脂肪酸的气相色谱/质谱(GC/MS)的测定方法。采用索氏提取法提取松茸中的粗脂肪,经过0.8mol/LKOH-甲醇溶液的甲酯化处理,并运用GC/MS联用技术对其脂肪酸进行了分离分析,同时结合有机质谱学规律,分别对饱和脂肪酸甲酯、单不饱和脂肪酸甲酯、多不饱和脂肪酸甲酯的裂解规律和质谱特征进行了分析归纳。通过质谱数据库检索,鉴定出长白山脉松茸中的9种主要脂肪酸,其中不饱和脂肪酸含量达86.2%,以油酸和亚油酸为主,油酸和亚油酸相对含量分别为34.2%和51.6%。通过对长白山区松茸中脂肪酸的分析,表明松茸是一种良好的保健营养植物,具有很好的开发利用前景。%A method of gas chromatography/mass spectrometry(GC/MS) was established to determine the fatty acids of Changbai mountain Tricholoma matsutake sing.The Tricholoma matsutake sing were extracted using Soxhlet extration method,derivatized with KOH-CH3OH solution,and analyzed by GC/MS.The fragmentation patterns and mass spectrometry characteristics of satutated fatty acids,monounsaturated,polyunsaturated fatty acids were analyzed and concluded by regular patterns of organic mass spectrometry.According to the database index,nine fatty acid components in Tricholoma matsutake sing were identified and the content of unsaturated fatty acid was 86.2%.The oleic acid(34.2%) and linoleic acid(51.6%) were main components among them.The qualitatived results of fatty acids in Tricholoma matsutake sing show that it is a good nutritional phant for health and it has better development and utilization prospect.

  7. [Simultaneous determination of 16 organic acids in feed additives by on-line enrichment and ion chromatography-mass spectrometry].

    Science.gov (United States)

    Xiong, Zhiyu; Dong, Ying; Zhou, Hongbin; Yu, Yang; Li, Jing; Sun, Li

    2014-02-01

    A novel analytical method for simultaneous determination of sixteen organic acids by on-line enrichment and ion chromatography-mass spectrometry (IC-MS) was developed. Online enrichment and separation of the organic acids were performed by ion chromatography on a homemade enrichment column and a homemade separation column. The qualitative and quantitative analyses of the organic acids were performed by mass spectrometry in selected ion monitoring (SIM) mode on the basis of atmospheric pressure chemical ionization (APCI) source in negative mode. The sample of 200 microL was injected for the analysis, and the on-line enrichment time was 3 min. The sodium hydroxide solution was used as a gradient elution system. The two columns made it possible to have a low limit of detection due to the good enrichment and separation capability. The sixteen organic acids were separated completely within 30 min. All curves showed good linearity within the test concentration ranges. The limits of detection (LODs) were between 0.01 and 0.22 mg/L, and the average recoveries were between 70.6% and 110.8%. The relative standard deviations (RSDs) were less than 6.3%. The results indicate that this method is simple, rapid, sensitive and accurate for the determination of the organic acids in feed additives.

  8. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    OpenAIRE

    Maryam Zokaei; Marzieh Kamankesh; Saeideh Shojaei; Abdorreza Mohammadi

    2016-01-01

    Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatizat...

  9. Determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, S C; Hung, C F; Wu, W B; Chen, B H

    2008-09-10

    The objectives of this study were to develop a high performance liquid chromatography-mass spectrometry (HPLC-MS) method for determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino, a traditional Chinese herb possessing vital biological activities. Chlorophylls were extracted with a quaternary solvent system of hexane-acetone-ethanol-toluene (10:7:6:7, v/v/v/v), followed by separation of a total of 15 chlorophylls and their derivatives within 32 min using a gradient mobile phase of acetone, acetonitrile and methanol and a HyPURITY C18 column, with detection at 660 nm and flow rate at 1 mL/min. Identification was carried out on the basis of retention behavior, absorption spectra and mass spectra using atmospheric pressure chemical ionization (APCI) in positive ion mode for detection. Of the 15 analytes, chlorophyll a, chlorophyll b, pheophytin a and pheophytin b were quantified by using standard calibration curves, with the other 11 being quantified with an internal standard Fast Green FCF. Chlorophyll extracts in G. pentaphyllum were found to contain pheophytin a (2508.3 microg/g), pheophytin a' (111.2 microg/g), chlorophyll a (113.8 microg/g), chlorophyll a' (11.0 microg/g), hydroxypheophytin a (88.6 microg/g), hydroxypheophytin a' (66.5 microg/g), pyropheophytin a (76.0 microg/g), hydroxychlorophyll a (23.8 microg/g), pheophytin b (319.6 microg/g), pheophytin b' (13.2 microg/g), chlorophyll b (287.9 microg/g), chlorophyll b' (11.1 microg/g), hydroxychlorophyll b (15.0 microg/g), hydroxypheophytin b (11.2 microg/g) and hydroxypheophytin b' (8.5 microg/g).

  10. Urine Mescaline Screening With a Biochip Array Immunoassay and Quantification by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Battal, Dilek; Barnes, Allan J; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-12-01

    Mescaline, the primary psychoactive chemical in peyote cactus, has been consumed for thousands of years in ancient religious ceremonies. The US military wanted to determine if mescaline intake was a problem for personnel readiness. Twenty thousand seventeen urine specimens negative for cannabinoids, cocaine, opiates, and amphetamines were tested for mescaline with the Randox Drugs of Abuse V (DOA-V) biochip array immunoassay at the manufacturer's recommended cutoff of 6 mcg/L. A sensitive and specific method for mescaline quantification in urine was developed and fully validated. Extracted analytes were derivatized with pentafluoropropionic anhydride and pentafluoropropanol and quantified by gas chromatography-mass spectrometry (GC/MS) with electron impact ionization. Standard curves, using linear least squares regression with 1/x weighting, were linear from 1 to 250 mcg/L with coefficients of determination >0.994. Intra- and inter-assay imprecision was 90.4%. Mean extraction efficiencies were >92.0% across the linear range. This fully validated method was applied for the confirmation of urinary mescaline in 526 presumptive-positive specimens and 198 randomly selected presumptive-negative specimens at the manufacturer's 6 mcg/L cutoff. No specimen confirmed positive at the GC/MS limit of quantification of 1 mcg/L. Results indicated that during this time frame, there was insufficient mescaline drug use in the military to warrant routine screening in the drug testing program. However, mescaline stability, although assessed, could have contributed to lower prevalence. We also present a validated GC/MS method for mescaline quantification in urine for reliable confirmation of suspected mescaline intake.

  11. Determination of endogenous ethanol in blood and breath by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jones, A W; Mårdh, G; Anggård, E

    1983-01-01

    We describe methods for the determination of endogenous ethanol in biological specimens from healthy abstaining subjects. The analytical methods were headspace gas chromatography (GC) for plasma samples and gas chromatography-mass spectometry (GC/MS) with deuterium labelled species 2H3-ethanol and 2H5-ethanol as internal standards for breath analysis. Ethanol in rebreathed air was about 10% higher than in directly analysed end-expired alveolar air. Known volumes of rebreathed air were passed through a liquid-N2 freeze trap and the volatile constituents of breath were concentrated prior to analysis by GC or GC/MS. Besides endogenous ethanol, peaks were seen on the chromatograms for methanol, acetone and acetaldehyde as well as several as yet unidentified substances. The endogenous alcohols ethanol and methanol were confirmed from their mass chromatograms and the GC/MS profile also indicated the presence of endogenous propan-1-ol. The concentration of endogenous ethanol in plasma showed wide inter-subject variations ranging from below detection limits to 1.6 micrograms/ml (34.8 mumol/l) and with mean +/- SD of 0.39 +/- 0.45 micrograms/ml (8.5 +/- 9.8 mumol/l). We aim to characterise further the role of endogenous ethanol with the main focus on dynamic aspects such as the rate of formation and turnover.

  12. 气质联用分析云南老树茶香气成分%The Analysis of Aroma Compositions in the Old Plant Tea by Gas Chromatography-mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    杨明容; 夏凯国; 张劲松; 马燕; 杨四润; 吴绍帅; 周红杰; 张春花; 袁文侠; 李亚莉; 任洪涛

    2012-01-01

    Old plant tea has a unique aroma and quality distinctive from other tea types. In order to better understand and develop it,and to solve the problem that old plant tea trees' information on the market is confusing. In this paper,the aroma compounds of nine representative old plant tea samples were extracted using simultaneous distillation and extraction method (SDE) and determined by capillary gas chromatography-mass spectrometry (GC-MS). In a total,63 aroma compounds were identified,including 20 kinds of hydrocarbons,15 kinds of alcohols,14 kinds of aldehydes,9 species of ketenes,8 kinds of organic acids,4 kinds of esters. The major aroma compounds are benzyl linalool as well as it' s oxidation products,α-terpineol,geraniol,methyl salicylate,furfur alcohol,β-ionone,benzaldehyde,benzeneacetaldehyde and (E,E)-2,4-Heptadienal. This paper revealed the aromatic compositions and features of old plant tea,and provided a scientific basis for the development and consumption of old plant tea.%老树茶是一种有别于其他茶类的茶,具有特殊的香气和品质,为了更好的认识和研发老树茶,解决老树茶在市场上信息混乱的问题,应用同时蒸馏萃取法(SDE)提取和气质联用色谱(GC/MS)分析9个具有代表的老树茶样品的香气成分.试验共鉴定出63种香气化合物,其中醇类15种、碳氢化合物13种、醛类14种、酮类9种、酸类8种、酯类4种;主要香气成分有芳樟醇及其氧化产物、α-松油醇、香叶醇、水杨酸甲酯、糠醇、β-紫罗兰酮、苯甲醛、苯乙醛、(E,E)-2,4-庚二烯醛等.研究初步探明老树茶的香气组成与特点,为老树茶的科学开发、消费提供科学依据.

  13. GC-MS法分析不同产地酿酒葡萄的香气成分%Analysis of aromatic components in the different wine-grapes from different geographic origin by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    商敬敏; 牟京霞; 刘建民; 张家荣; 邓波; 史涛涛; 赵新节

    2011-01-01

    The aromatic components from fresh grape were extracted by steam distillation, analyzed by Gas Chromatography/Mass Spec-trometry (GC/MS). The materials were from Hebei Changli and Yantai Penglai. Including Sauvignon Cabernet, Muscat Hambourg and Sauvignon Gerniseht. There were 85 components identified in the three varieties from the two geographic origin, they are mainly alcohols, esters. In the aroma compounds, palmitic acid and 2,4-Di-tert-butyl phenol lies in all the varieties, and the falcarinol was ana-lized in the Sauvignon Gerniseht of Penglai, which were the first determined in the grape and wine. The result determined that the contents of the same variety aroma components in the same varieties were similar, but the aroma trace components were significantly different, which led to characteristic aroma and style for the different varieties, and they would contribute to the protection of the geographic origin.%以昌黎和蓬莱的酿酒葡萄浆果为试验材料,采用水蒸汽蒸馏法提取赤霞珠、玫瑰香和蛇龙珠葡萄浆果中的香气成分,并用气相色谱-质谱对样品进行分析.结果表明,6个样品共检出85种香气成分,以醇类和酯类最为主.在检出的香气物质中,棕榈酸和2,4-二叔丁基苯酚是6个样品共有的,同时在蓬莱蛇龙珠中还检出具有强抗癌抑癌活性的镰叶芹醇.说明相同成分在同一品种中的含量相差不大,但微量香气成分有较大差别,为葡萄酒原产地保护提供了理论依据.

  14. 气相色谱-质谱法分析棕榈果脂肪酸组成%Analysis of Fatty Acid Composition in Oil Palm Fruit by Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    沈丹玉; 汤富彬; 钟冬莲; 倪张林; 屈明华; 莫润宏

    2012-01-01

    Palm oil and palm kernel oil were extracted by a soxhlet extractor, and esterfied with potassium hydroxide - methanol. The fatty acid compositions were determined by gas chromatography - mass spectrometry. Nine fatty acids were identified and quantified respectively. The relative content of saturated fatty acids from palm oil was 49.5 % , and existing forms were mainly palmitic acid and stearic acid. The unsaturated fatty acids were constituted of oleic acid, linoleic acid, linolenic acid and cis -13,16 - docosadienoic acid. The relative content of saturated fatty acids from palm kernel oil was more than 80, and lauric acid had the highest content obtained with content of 41.5% among them. The other main compositions were myristic acid, palmitic acid, hexanoic acid, octanoic acid, capric acid and stearic acid. Oleic acid and linoleic acid constituted the unsaturated fatty acids.%采用索氏抽提法分别提取棕榈果肉和棕榈果仁中的油脂,以氢氧化钾—甲醇溶液对油脂进行甲酯化处理,用气相色谱-质谱( GC-MS)法分析.从棕榈果肉和棕榈仁的油脂中均分离并鉴定了9种脂肪酸,其中棕榈果肉中饱和脂肪酸质量分数为49.5%,主要有棕榈酸和硬脂酸,不饱和脂肪酸主要有油酸、亚油酸以及少量的亚麻酸和13,16-二十二碳二烯酸.棕榈仁中饱和脂肪酸80%以上,其中月桂酸质量分数达到41.5%,肉豆蔻酸和棕榈酸含量也较高,此外还含有少量的己酸、辛酸、癸酸和硬脂酸,不饱和脂肪酸有油酸和亚油酸.

  15. Analysis of Volatile Compounds from Litsea cubeba Female Flower by Solid Phase Microextraction and Gas Chromatography Mass Spectrometry%山苍子雌花挥发性成分的 SPME -GC/MS 分析

    Institute of Scientific and Technical Information of China (English)

    陈萍; 王建刚

    2015-01-01

    The research aimed to analyze the chemical compounds in female flowers of Litsea cubeba and their relative content.Under optimized extraction conditions , headspace solid -phase micro extraction (HS -SPME) coupled with gas chromatography -mass spectrometry (GC -MS) was used to the extraction and determination of the volatile compounds in female flowers of Litsea cubeba.66 peaks were separated and 59 compounds were identified.The relative of each compound was determined, including alpha -Pinene (5.52 %),4(10) -Thujen(30.20%),beta -Pinene(4.95 %),alpha -Phellandrene(8.97 %),D -Limonene(8.56 %),Eucalyptol(10.05 %),alpha -Terpineol(5.41 %)etc.The study on the volatile compounds from female flowers of Litsea cubeba provided the test basis for the further development and utilization of Litsea cubeba resources .%采用顶空固相微萃取(HS -SPME)和气相色谱质谱联用(GC -MS)技术对山苍子雌花挥发性化学成分进行分离鉴定,用色谱峰面积归一化法确定各组分的相对含量。从山苍子雌花挥发性物质中分离出了66个组分,鉴定出了59个组分,并测定了各组分相对含量,包括α-蒎烯(5.52%),桧烯(30.20%),β-蒎烯(4.95%),α-水芹烯(8.97%),D -柠檬烯(8.56%),桉叶油醇(10.05%),α-松油醇(5.41%)等。通过对山苍子雌花挥发性成分的研究,为山苍子资源的进一步开发利用提供了参考依据。

  16. Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry.

    Science.gov (United States)

    De Pinho, P Guedes; Gonçalves, Rui F; Valentão, Patrícia; Pereira, David M; Seabra, Rosa M; Andrade, Paula B; Sottomayor, Mariana

    2009-04-05

    A total of 88 volatile and semi-volatile components were formally or tentatively identified in flowers, leaves and stems of Catharanthus roseus (L.) G. Don (cv. Little Bright Eye), by headspace solid-phase microextraction (HS-SPME) and by dichloromethane extraction, combined with gas chromatography-mass spectrometry (GC-MS). These include some diterpenic compounds (manool and manoyl oxides), a sesquiterpen (alpha-bisabolol), and some pyridine, pyrazine, indol and carotenoid derivatives. Applying multivariate analysis (principal component analysis and agglomerative hierarchic cluster analysis) to the HS-SPME-GC-MS data, it was possible to characterize each part of the vegetal material using a relative small number of compounds. Hence, flowers were richer in terpenic molecules (including limonene), alpha-bisabolol, methyljasmonate, cis-jasmone, 2-phenylethanol, phenylacetaldehyde, trans-2-octenal, benzylic alcohol and 2-isobutyl-3-methoxypyrazine. Leaves can be characterized by the methyl and propyl esters of fatty acids, mono- and disaturated, trans-phytol, carotenoid derivative compounds, hydrofarnesylacetone, methylanthranilate, manool and epi-manool oxide, while stems have high levels of volatile aldehydes, such as hexanal, octanal, cis-2-nonenal, cis-2-decenal, cis, trans-2,6-nonadienal, trans, trans-2,4-decadienal and cis, trans-2,4-decadienal. Dichloromethane extraction allowed also the identification of some alkaloid-like compounds that were not detected by HS-SPME.

  17. An evaluation of acute hydrogen sulfide poisoning in rats through serum metabolomics based on gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Meiling; Deng, Mingjie; Ma, Jianshe; Wang, Xianqin

    2014-01-01

    Hydrogen sulfide (H2S) is the second leading cause of toxin-related deaths in the operational site. Its main target organs of toxic effects are the central nervous system and respiratory system. In this study, we developed a serum metabonomic method, based on gas chromatography-mass spectrometry (GC/MS), to evaluate the effect of acute poisoning by hydrogen sulfide on rats. Pattern recognition analysis, including both principal component analysis (PCA) and partial least squares-discriminate analysis (PLS-DA), revealed that acute hydrogen sulfide poisoning induced metabolic perturbations. Compared to the control group, the level of urea, glucose, glyceryl stearate in rat serum of the poisoning group increased after two hours, and the level of glucose, docosahexaenoic acid, glyceryl stearate and arachidonic acid in rat serum of the poisoning group increased after 48 h, while the L-valine, galactose, L-tyrosine levels decreased. Our results indicate that metabonomic methods based on GC/MS may be useful to elucidate acute hydrogen sulfide poisoning through the exploration of biomarkers.

  18. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  19. A gas chromatography-mass spectrometry based study on urine metabolomics in rats chronically poisoned with hydrogen sulfide.

    Science.gov (United States)

    Deng, Mingjie; Zhang, Meiling; Sun, Fa; Ma, Jianshe; Hu, Lufeng; Yang, Xuezhi; Lin, Guanyang; Wang, Xianqin

    2015-01-01

    Gas chromatography-mass spectrometry (GS-MS) in combination with multivariate statistical analysis was applied to explore the metabolic variability in urine of chronically hydrogen sulfide- (H2S-) poisoned rats relative to control ones. The changes in endogenous metabolites were studied by partial least squares-discriminate analysis (PLS-DA) and independent-samples t-test. The metabolic patterns of H2S-poisoned group are separated from the control, suggesting that the metabolic profiles of H2S-poisoned rats were markedly different from the controls. Moreover, compared to the control group, the level of alanine, d-ribose, tetradecanoic acid, L-aspartic acid, pentanedioic acid, cholesterol, acetate, and oleic acid in rat urine of the poisoning group decreased, while the level of glycine, d-mannose, arabinofuranose, and propanoic acid increased. These metabolites are related to amino acid metabolism as well as energy and lipid metabolism in vivo. Studying metabolomics using GC-MS allows for a comprehensive overview of the metabolism of the living body. This technique can be employed to decipher the mechanism of chronic H2S poisoning, thus promoting the use of metabolomics in clinical toxicology.

  20. A Gas Chromatography-Mass Spectrometry Based Study on Urine Metabolomics in Rats Chronically Poisoned with Hydrogen Sulfide

    Directory of Open Access Journals (Sweden)

    Mingjie Deng

    2015-01-01

    Full Text Available Gas chromatography-mass spectrometry (GS-MS in combination with multivariate statistical analysis was applied to explore the metabolic variability in urine of chronically hydrogen sulfide- (H2S- poisoned rats relative to control ones. The changes in endogenous metabolites were studied by partial least squares-discriminate analysis (PLS-DA and independent-samples t-test. The metabolic patterns of H2S-poisoned group are separated from the control, suggesting that the metabolic profiles of H2S-poisoned rats were markedly different from the controls. Moreover, compared to the control group, the level of alanine, d-ribose, tetradecanoic acid, L-aspartic acid, pentanedioic acid, cholesterol, acetate, and oleic acid in rat urine of the poisoning group decreased, while the level of glycine, d-mannose, arabinofuranose, and propanoic acid increased. These metabolites are related to amino acid metabolism as well as energy and lipid metabolism in vivo. Studying metabolomics using GC-MS allows for a comprehensive overview of the metabolism of the living body. This technique can be employed to decipher the mechanism of chronic H2S poisoning, thus promoting the use of metabolomics in clinical toxicology.

  1. [Determination of nonylphenol in wastewater by solid phase extraction gas chromatography mass spectrometry and multi-selective ions].

    Science.gov (United States)

    Hao, Rui-Xia; Liang, Peng; Zhao, Man; Wang, Jun-An; Zhou, Yu-Wen

    2006-11-01

    Nonylphenol (NP) having endocrine disrupter activity is an ultra trace component in sewage and reuse wastewater. There are many NP isomers in the wastewater because nonyl structure is different. The background impurity of the samples is very complex with many other components. So it is difficulty for quantitative analysis of NP in the samples. About seventy sewages and recycled wastewater samples were measured for the content of NP isomer mixtures by solid-phase extraction-gas chromatography-mass spectrometry and multi-selected ions monitoring (shortened as SPE-GC-MS-SIM). The results show that hydrophilic-lipophilic-equilibrium solid-phase extraction pole has selective adsorption for NP, so that the samples can be concentrated from 50 to 200 times. The five kinds of mass spectrum ions, i. e. 107, 121, 135, 149, 163, have higher abundance and distinct character. The sum of five selected ion monitoring (sigmaSIM) is from 54.4 to 73 percent of the total ion current for NP, which can accurately represent different NP isomers. Quantitative analysis base on the spectral integralof the sigmaSIM chromatograph can eliminate interference with background signal and ensure selectivity, accuracy and precision ofthe method.

  2. Evaluation of dried blood spots as sample matrix for gas chromatography/mass spectrometry based metabolomic profiling.

    Science.gov (United States)

    Kong, Sing Teang; Lin, Hai-Shu; Ching, Jianhong; Ho, Paul C

    2011-06-01

    We propose using dried blood spots (DBS) as sample matrix for gas chromatography/mass spectrometry (GC/MS) based metabolomic profiling for the benefits of higher sample stability, more convenient sample acquisition with DBS, higher analyte separation power, and more readily biomarker identification with GC/MS. To establish this proposition, the metabolomic profiles generated from DBS were compared with that obtained from the conventional whole blood and plasma matrixes and also with dried plasma spots (DPS) as another covariate control. Our findings indicated that whole blood produced the most number of detectable markers (866), whereas DPS yielded the least number (614). DBS and plasma matrix, on the other hand, produced the most similar numbers of detectable (695 vs 749) and identifiable markers (137 vs 147, matching with Fiehn library). From the analysis of the DBS and plasma metabolomic profiles, it was concluded that when l-lysine 2, iminodiacetic acid 2, dl-threo-beta-hydroxyaspartic acid, citric acid, or adenosine-5-monophosphate 2 are not involved as markers, DBS could be a suitable substitute for plasma for metabolomic profiling.

  3. Trace determination of the flame retardant tetrabromobisphenol A in the atmosphere by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xie Zhiyong [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany) and Johann Wolfgang Goethe-University Frankfurt at Main, Institute of Atmospheric and Environmental Sciences, Department of Analytical Environmental Chemistry, Georg-Voigt-Str. 14, 60054 Frankfurt (Germany)]. E-mail: zhiyong.xie@gkss.de; Ebinghaus, Ralf [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany); Lohmann, Rainer [Graduate School of Oceanography, University of Rhode Island, Narragansett, RI 02882-1197 (United States); Heemken, Olaf [LAVES, Philosophenweg 36/38, D-26121 Oldenburg (Germany); Caba, Armando [GKSS Research Centre, Institute for Coastal Research, Department of Environmental Chemistry, Max-Planck-Str. 1, D-21502 Geesthacht (Germany); Puettmann, Wilhelm [Johann Wolfgang Goethe-University Frankfurt at Main, Institute of Atmospheric and Environmental Sciences, Department of Analytical Environmental Chemistry, Georg-Voigt-Str. 14, 60054 Frankfurt (Germany)

    2007-02-19

    A simple and effective method has been developed for analysis of the flame retardant tetrabromobisphenol A (TBBPA) in environmental samples by using modified soxhlet extraction in combination with silica gel clean-up, derivatization with silylation reagent and gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring mode (SIM). Satisfactory recoveries were achieved for the large volume sampling, soxhlet extraction and silica gel clean-up. The overall recovery is 79 {+-} 1%. The derivatization procedure is simple and fast, and produces stable TBBPA derivative. GC-MS with electronic impact (EI) ionization mode shows better detection power than using negative chemical ionization (NCI) mode. EI gives a method detection limit of 0.04 pg m{sup -3} and enables to determine trace TBBPA in ambient air in remote area. The method was successfully applied to the determination of TBBPA in atmospheric samples collected over land and coastal regions. The concentrations of TBBPA ranged from below the method detection limit (0.04 pg m{sup -3}) to 0.85 pg m{sup -3}. A declining trend with increasing latitude was present from the Wadden Sea to the Arctic. The atmospheric occurrence of TBBPA in the Arctic is significant and might imply that TBBPA has long-range transport potential.

  4. Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method

    Directory of Open Access Journals (Sweden)

    Simona Nicoara

    2009-01-01

    Full Text Available The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B, toluene (T, ethyl benzene (E, and o-, m-, p-xylenes (X. Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m3 (B, 13–90 μg/m3 (T, 7–50 μg/m3 (E, 10–70 μg/m3 (X-m,p, and 20–130 μg/m3 (X-o. The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m3 (Xo, 5/3 μg/m3 (B, E, X-m,p, and of 3/1 μg/m3 (T, respectively.

  5. Simultaneous determination of five anti-epilepsy drugs in human plasma using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    STEFANIE; WeiBig

    2010-01-01

    A new liquid chromatography-mass spectrometry method for the determination of carbamazepine,clonazepam,alprazolam,estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard.Chromatographic separation was performed on a Zorbax SB-C18 column(30 mm × 2.1 mm,3.5 ?m) with a mobile phase consisting of methanol and aqueous 25 mM ammonium acetate using gradient elution.A diethyl ether extraction method was used for the extraction of five anti-epilepsy drugs.The final extract was injected for analysis by LC-MS/MS.The method was validated within the concentration range of 50-5000 ng mL-1 for five anti-epilepsy drugs.The precision of the assay(RSD%) was less than 10% at all concentration levels within the tested range.The method recoveries for all samples were more than 90%.The results indicate that the method is specific,sensitive and accurate,and suitable to study the pharmacokinetics,to adjust the dosage for individual administration,and to monitor the drug-concentration and drug abuse of the five anti-epilepsy drugs.

  6. [Determination of short chain chlorinated paraffins in leather products by solid phase extraction coupled with gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun

    2014-10-01

    The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.

  7. Metabolic Toxicity Screening Using Electrochemiluminescence Arrays Coupled with Enzyme-DNA Biocolloid Reactors and Liquid Chromatography-Mass Spectrometry

    Science.gov (United States)

    Hvastkovs, Eli, G.; Schenkman, John B.; Rusling, James, F.

    2012-07-01

    New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography-mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates.

  8. Analytical Approaches Based on Gas Chromatography Mass Spectrometry (GC/MS) to Study Organic Materials in Artworks and Archaeological Objects.

    Science.gov (United States)

    Bonaduce, Ilaria; Ribechini, Erika; Modugno, Francesca; Colombini, Maria Perla

    2016-02-01

    Gas chromatography/mass spectrometry (GC/MS), after appropriate wet chemical sample pre-treatments or pyrolysis, is one of the most commonly adopted analytical techniques in the study of organic materials from cultural heritage objects. Organic materials in archaeological contexts, in classical art objects, or in modern and contemporary works of art may be the same or belong to the same classes, but can also vary considerably, often presenting different ageing pathways and chemical environments. This paper provides an overview of the literature published in the last 10 years on the research based on the use of GC/MS for the analysis of organic materials in artworks and archaeological objects. The latest progresses in advancing analytical approaches, characterising materials and understanding their degradation, and developing methods for monitoring their stability are discussed. Case studies from the literature are presented to examine how the choice of the working conditions and the analytical approaches is driven by the analytical and technical question to be answered, as well as the nature of the object from which the samples are collected.

  9. Characterisation and discrimination of various types of lac resin using gas chromatography mass spectrometry techniques with quaternary ammonium reagents.

    Science.gov (United States)

    Sutherland, K; del Río, J C

    2014-04-18

    A variety of lac resin samples obtained from artists' suppliers, industrial manufacturers, and museum collections were analysed using gas chromatography mass spectrometry (GCMS) and reactive pyrolysis GCMS with quaternary ammonium reagents. These techniques allowed a detailed chemical characterisation of microgram-sized samples, based on the detection and identification of derivatives of the hydroxy aliphatic and cyclic (sesquiterpene) acids that compose the resin. Differences in composition could be related to the nature of the resin, e.g. wax-containing (unrefined), bleached, or aged samples. Furthermore, differences in the relative abundances of aliphatic hydroxyacids appear to be associated with the biological source of the resin. The diagnostic value of newly characterised lac components, including 8-hydroxyacids, is discussed here for the first time. Identification of derivatised components was aided by AMDIS deconvolution software, and discrimination of samples was enhanced by statistical evaluation of data using principal component analysis. The robustness of the analyses, together with the minimal sample size required, make these very powerful approaches for the characterisation of lac resin in museum objects. The value of such analyses for enhancing the understanding of museum collections is illustrated by two case studies of objects in the collection of the Philadelphia Museum of Art: a restorer's varnish on a painting by Luca Signorelli, and a pictorial inlay in an early nineteenth-century High Chest by George Dyer.

  10. Rapid determination of polysaccharides in BianTi Soft extract by spectrophotometry coupled with gas chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Minxia Zheng

    2010-01-01

    Full Text Available A simple approach for the rapid determination of polysaccharides in BianTi Soft Extract using spectrophotometry coupled with gas chromatography-mass spectrometry (GC-MS was developed. The mixed standard solution composed of D-glucose, D-mannose, galactose and D-xylose in different proportions (1.00: 1.01: 0.12: 0.05 was prepared according to the monosaccharide composition analysis of the polysaccharides by GC-MS. The determination of polysaccharides by UV-Vis spectrophotometer was performed after 35-min color reaction, in which 1 ml 5% phenol and 4 ml sulfate was used. The assay of the method validation has shown that the method was stable, reliable and feasible. Furthermore, the proposed method was successfully applied in the preparation procedure of BianTi Soft Extract, selecting out optimal decoction conditions and suitable decoction container. It suggests that the convenient method could be useful for the quality control of BianTi Soft Extract. Meanwhile, it may be an alternative for polysaccharides determination of other formulations.

  11. Determination of carbon number distributions of complex phthalates by gas chromatography-mass spectrometry with ammonia chemical ionization.

    Science.gov (United States)

    Di Sanzo, Frank P; Lim, Peniel J; Han, Wenning W

    2015-01-01

    An assay method for phthalate esters with a complex mixture of isomer of varying carbon numbers, such as di-isononyl phthalate (DINP) and di-isodecyl phthalate (DIDP), using gas chromatography-mass spectrometry (GC-MS) positive chemical ionization (PCI) with 5% ammonia in methane is described. GC-MS-PCI-NH3, unlike GC-MS electron ionization (EI) (GC-MS-EI) that produces generally m/z 149 ion as the main base peak and low intensity M(+) peaks, produces higher intensity (M + 1) ions that allow the determination of total (R + R') carbon number distributions based on the various R and R' alkyl groups of the di-esters moiety. The technique allows distinguishing among the various commercial DINP and DIDP plasticizers. The carbon number distributions are determined in the acceptable range of 85 mole percent (m/m). Several examples of analysis made on commercial DINP and DIDP are presented. The use of only 5% instead of 100% ammonia simplifies use of GC-MS-PCI-NH3 but still produces sufficient M + 1 ion intensities that are appropriate for the assay. In addition, use of low concentrations of ammonia mitigates potential safety aspects related to use of ammonia and provides less corrosion for the instrument hardware.

  12. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS.

  13. [Characterization of pyrolysis of waste printed circuit boards by high-resolution pyrolysis gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhang, Yanhong; Huang, Hong; Xia, Zhengbin; Chen, Huanqin

    2008-07-01

    Thermal degradation of pyrolysis of waste circuit boards was investigated by high-resolution pyrolysis gas chromatography-mass spectrometry (PyGC-MS) and thermogravimetry (TG). In helium atmosphere, the products of FR-4 waste printed circuit board were pyrolyzed at 350, 450, 550, 650, and 750 degrees degrees C, separately, and the pyrolysis products were identified by online MS. The results indicated that the pyrolysis products of the FR-4 waste circuit board were three kinds of substances, such as the low boiling point products, phenol, bisphenol and their related products. Moreover, under 300 degrees degrees C, only observed less pyrolysis products. As the increase of pyrolysis temperature, the relative content of the low boiling point products increased. In the range of 450-650 degrees degrees C, the qualitative analysis and character were similar, and the relative contents of phenol and bisphenol were higher. The influence of pyrolysis temperature on pyrolyzate yields was studied. On the basis of the pyrolyzate profile and the dependence of pyrolyzate yields on pyrolysis temperature, the thermal degradation mechanism of brominated epoxy resin was proposed.

  14. Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assay.

    Science.gov (United States)

    Wang, Xiu-Li; Zhu, Ying; Fang, Qun

    2014-01-07

    In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10-100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.

  15. Comparison of gas chromatography/mass spectrometry and immunoassay techniques on concentrations of atrazine in storm runoff

    Science.gov (United States)

    Lydy, Michael J.; Carter, D.S.; Crawford, Charles G.

    1996-01-01

    Gas chromatography/mass spectrometry (GC/MS) and enzyme-linked immunosorbent assay (ELISA) techniques were used to measure concentrations of dissolved atrazine in 149 surface-water samples. Samples were collected during May 1992–September 1993 near the mouth of the White River (Indiana) and in two small tributaries of the river. GC/MS was performed on a Hewlett-Packard 5971 A, with electron impact ionization and selected ion monitoring of filtered water samples extracted by C-18 solid phase extraction; ELISA was performed with a magnetic-particle-based assay with photometric analysis. ELISA results compared reasonably well to GC/MS measurements at concentrations below the Maximum Contaminant Level for drinking water set by the U.S. Environmental Protection Agency (3.0 μg/L), but a systematic negative bias was observed at higher concentrations. When higher concentration samples were diluted into the linear range of calibration, the relation improved. A slight positive bias was seen in all of the ELISA data compared to the GC/MS results, and the bias could be partially explained by correcting the ELISA data for cross reactivity with other triazine herbicides. The highest concentrations of atrazine were found during the first major runoff event after the atrazine was applied. Concentrations decreased throughout the rest of the sampling period even though large runoff events occurred during this time, indicating that most atrazine loading to surface waters in the study area occurs within a few weeks after application.

  16. Oligosaccharide substrate preferences of human extracellular sulfatase Sulf2 using liquid chromatography-mass spectrometry based glycomics approaches.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Sulfs are extracellular endosulfatases that selectively remove the 6-O-sulfate groups from cell surface heparan sulfate (HS chain. By altering the sulfation at these particular sites, Sulfs function to remodel HS chains. As a result of the remodeling activity, HSulf2 regulates a multitude of cell-signaling events that depend on interactions between proteins and HS. Previous efforts to characterize the substrate specificity of human Sulfs (HSulfs focused on the analysis of HS disaccharides and synthetic repeating units. In this study, we characterized the substrate preferences of human HSulf2 using HS oligosaccharides with various lengths and sulfation degrees from several naturally occurring HS sources by applying liquid chromatography mass spectrometry based glycomics methods. The results showed that HSulf2 preferentially digests highly sulfated HS oligosaccharides with zero acetyl groups and this preference is length dependent. In terms of length of oligosaccharides, HSulf2 digestion induced more sulfation decrease on DP6 (DP: degree of polymerization compared to DP2, DP4 and DP8. In addition, the HSulf2 preferentially digests the oligosaccharide domain located at the non-reducing end (NRE of the HS and heparin chain. In addition, the HSulf2 digestion products were altered only for specific isomers. HSulf2 treated NRE oligosaccharides also showed greater decrease in cell proliferation than those from internal domains of the HS chain. After further chromatographic separation, we identified the three most preferred unsaturated hexasaccharide for HSulf2.

  17. Validation of biomarkers for distinguishing Mycobacterium tuberculosis from non-tuberculous mycobacteria using gas chromatography-mass spectrometry and chemometrics.

    Directory of Open Access Journals (Sweden)

    Ngoc A Dang

    Full Text Available Tuberculosis (TB remains a major international health problem. Rapid differentiation of Mycobacterium tuberculosis complex (MTB from non-tuberculous mycobacteria (NTM is critical for decisions regarding patient management and choice of therapeutic regimen. Recently we developed a 20-compound model to distinguish between MTB and NTM. It is based on thermally assisted hydrolysis and methylation gas chromatography-mass spectrometry and partial least square discriminant analysis. Here we report the validation of this model with two independent sample sets, one consisting of 39 MTB and 17 NTM isolates from the Netherlands, the other comprising 103 isolates (91 MTB and 12 NTM from Stellenbosch, Cape Town, South Africa. All the MTB strains in the 56 Dutch samples were correctly identified and the model had a sensitivity of 100% and a specificity of 94%. For the South African samples the model had a sensitivity of 88% and specificity of 100%. Based on our model, we have developed a new decision-tree that allows the differentiation of MTB from NTM with 100% accuracy. Encouraged by these findings we will proceed with the development of a simple, rapid, affordable, high-throughput test to identify MTB directly in sputum.

  18. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis.

  19. Effect of piperine on pharmacokinetics of sodium valproate in plasma samples of rats using gas chromatography-mass spectrometry method

    Directory of Open Access Journals (Sweden)

    Bushra Parveen

    2015-01-01

    Full Text Available Piperine (PIP is used as anticonvulsant in traditional Chinese medicine. Co-administration of low-dose sodium valproate with PIP has been regarded to have potential anticonvulsant activity. Aim: This study was intended to investigate the effect of PIP on the pharmacokinetics of sodium valproate (SVP in the plasma samples of rats using gas chromatography-mass spectrometry (GC-MS method. Materials and Methods: The plasma samples obtained after oral administration of SVP, 150 mg/kg and SVP, 150 mg/kg + PIP, and 5 mg/kg to male Wistar rats were used to quantify the concentrations in plasma using GC-MS method. Results: A simple and accurate method developed in-house was applied for the analysis of plasma samples of Wistar rats after oral administration of SVP and PIP + sodium valproate, respectively. The pharmacokinetic parameters reported 14.8-fold increase in plasma concentration (maximum observed concentration in the concentration-time profile, 4.6-fold increase in area under the curve and slightly prolonged time to reach that concentration (1 h of SVP in presence of PIP. Conclusion: The study reaffirms the bioenhancing effect of PIP suggesting possibility of dose reduction of SVP while co-adminstering with PIP.

  20. Sequential derivatization of polar organic compounds in cloud water using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride, N,O-bis(trimethylsilyl)trifluoroacetamide, and gas-chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A

    2014-10-03

    Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and

  1. Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Mahaffy, P. R.

    2004-01-01

    One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds

  2. Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Mahaffy, P. R.

    2004-01-01

    One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds

  3. Application of Solid-phase Microextraction Gas Chromatography-Mass Spectrometry in Analysis of Poison%固相微萃取-气相色谱-质谱-SIR技术在痕量毒物分析中的应用

    Institute of Scientific and Technical Information of China (English)

    蔡锡兰; 吴国萍

    2004-01-01

    A simple and sensitive liquid chromatography-mass spectrometric technique coupled with solid-phase microextraction (SPE) method was describéd for the determination of fluoroacetamide in a poison case. The experimental conditions of SPE and the probe of SPE were discussed, recovery rate and precision were investigated. The results showed that the detection limit of fluoroacetamide is 0. 1mg/L, the average recovery is 99.2%.

  4. Detection of VX contamination in soil through solid-phase microextraction sampling and gas chromatography/mass spectrometry of the VX degradation product bis(diisopropylaminoethyl)disulfide.

    Science.gov (United States)

    Hook, Gary L; Kimm, Gregory; Koch, David; Savage, Paul B; Ding, Bangwei; Smith, Philip A

    2003-04-11

    A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) sampling and analysis method was developed for bis(diisopropylaminoethyl)disulfide (a degradation product of the nerve agent VX) in soil. A 30-min sampling time with a polydimethylsiloxane-coated fiber and high temperature alkaline hydrolysis allowed detection with 1.0 microg of VX spiked per g of agricultural soil. The method was successfully used in the field with portable GC-MS instrumentation. This method is relatively rapid (less than 1 h), avoids the use of complex preparation steps, and enhances analyst safety through limited use of solvents and decontamination of the soil before sampling.

  5. 分子蒸馏技术拆分独活油及GC-MS分析%Gas chromatography/Mass Spectrometry (GC-MS) Analysis of the Essential Oil from Angelica Pubescens Maxim. by Molecular Distillation Separation

    Institute of Scientific and Technical Information of China (English)

    侯召华; 邹飞雪

    2015-01-01

    The essential oil was extracted from Angelica pubescens Maxim. by steam distillation and fractionated by molecular distillation ( MD ) . The crude essential oil was used as the feed for two molecular distillation processes. One residue ( RF2 ) and two distillate ( DF1 and DF2 ) fractions were prepared by MD. Three fractions were obtained under the operation parameters of 30 ℃,5. 0mbar;and 60℃, 5. 0mbar, respectively. The chemical components of different fractions were analyzed by Gas chromatography/mass spectrometry ( GC-MS) . Results:The yields of distilled fractions ( DF1 ,and DF2 ) and residued fractions (RF2)were 33. 65%,61. 39%,and 3. 88% (w/w),respectively. GC-MS results revealed that 21 ingredients were detected in the essential oil, including (+)-Limonene,α-Pinene,β-Pinene, Terpinen-4-ol, Eucalyptol, Terpinolene, and (-)-Carveol et. Concentrations and compositions of chemical components in different factions were significantly different. In conclusion, the technology of molecular distillation is a feasible separaction method for essential oil.%独活原油由水蒸汽蒸馏法得到,经过分子蒸馏拆分,得到不同馏分,进行气相色谱-质谱( GC-MS)分析。分子蒸馏为二级,一级条件:蒸发温度30℃、真空度500 Pa、刮膜转速150 r/min;二级条件:蒸发温度60℃、真空度500 Pa、刮膜转速200 r/min;两级进样温度30℃、冷凝水温度10℃。两级分子蒸馏共得到3部分,总上样量336.17 g,回收得到332.51 g,回收率98.92%;一级轻组分(DF1)113.12 g(33.65%);二级轻组分(DF2)206.36 g (61.39%);二级重组分(RF2)13.03 g,所占质量比3.88%。原油和馏分物中共确定21种化合物,主要是右旋萜二烯、α-蒎烯、4-异丙基甲苯、萜品烯、月桂烯等;三部分馏分物( DF1,DF2和RF2)和原油中组分数量分别为8、10、17和6种;且不同组分中成分数量及浓度差异显著。分子蒸馏是一种有效的分离纯化技术,可应用于挥发油的加工利用。

  6. Quantitative proteomic analysis of Pseudomonas pseudoalcaligenes CECT5344 in response to industrial cyanide-containing wastewaters using Liquid Chromatography-Mass Spectrometry/Mass Spectrometry (LC-MS/MS)

    Science.gov (United States)

    Ibáñez, María Isabel; Cabello, Purificación; Luque-Almagro, Víctor Manuel; Sáez, Lara P.; Olaya, Alfonso; Sánchez de Medina, Verónica; Luque de Castro, María Dolores; Moreno-Vivián, Conrado; Roldán, María Dolores

    2017-01-01

    Biological treatments to degrade cyanide are a powerful technology for cyanide removal from industrial wastewaters. It has been previously demonstrated that the alkaliphilic bacterium Pseudomonas pseudoalcaligenes CECT5344 is able to use free cyanide and several metal−cyanide complexes as the sole nitrogen source. In this work, the strain CECT5344 has been used for detoxification of the different chemical forms of cyanide that are present in alkaline wastewaters from the jewelry industry. This liquid residue also contains large concentrations of metals like iron, copper and zinc, making this wastewater even more toxic. To elucidate the molecular mechanisms involved in the bioremediation process, a quantitative proteomic analysis by LC-MS/MS has been carried out in P. pseudoalcaligenes CECT5344 cells grown with the jewelry residue as sole nitrogen source. Different proteins related to cyanide and cyanate assimilation, as well as other proteins involved in transport and resistance to metals were induced by the cyanide-containing jewelry residue. GntR-like regulatory proteins were also induced by this industrial residue and mutational analysis revealed that GntR-like regulatory proteins may play a role in the regulation of cyanide assimilation in P. pseudoalcaligenes CECT5344. The strain CECT5344 has been used in a batch reactor to remove at pH 9 the different forms of cyanide present in industrial wastewaters from the jewelry industry (0.3 g/L, ca. 12 mM total cyanide, including both free cyanide and metal−cyanide complexes). This is the first report describing the biological removal at alkaline pH of such as elevated concentration of cyanide present in a heterogeneous mixture from an industrial source. PMID:28253357

  7. Metabolomics study with gas chromatography-mass spectrometry for predicting valproic acid-induced hepatotoxicity and discovery of novel biomarkers in rat urine.

    Science.gov (United States)

    Lee, Min Sun; Jung, Byung Hwa; Chung, Bong Chul; Cho, Sung Hee; Kim, Ki Young; Kwon, Oh Seoung; Nugraha, Boya; Lee, Young-Joo

    2009-01-01

    Three different doses of valproic acid (20, 100, and 500 mg/kg/d) are administered orally to Sprague-Dawley rats for 5 days, and the feasibility of metabolomics with gas chromatography-mass spectrometry as a predictor of the hepatotoxicity of valproic acid is evaluated. Body weight is found to decrease with the 100-mg/kg/d dose and significantly decrease with the 500-mg/kg/d dose. Mean excreted urine volume is lowest in the 500-mg/kg/d group among all groups. The plasma level of alpha-glutathione-S-transferase, a sensitive and earlier biomarker for hepatotoxicity, increases significantly with administration of 100 and 500 mg/kg/d; however, there is not a significant difference in alpha-glutathione-S-transferase plasma levels between the control and 20-mg/kg/d groups. Clusters in partial least squares discriminant analysis score plots show similar patterns, with changes in physiological conditions and plasma levels of alpha-glutathione-S-transferase; the cluster for the control and 20-mg/kg/d groups does not clearly separate, but the clusters are separate for 100- and 500-mg/kg/d groups. A biomarker of hepatotoxicity, 8-hydroxy-2'-deoxyguanosine and octanoylcarnitine, is identified from nontargeted and targeted metabolic profiling. These results validate that metabolic profiling using gas chromatography-mass spectrometry could be a useful tool for finding novel biomarkers. Thus, a nontargeted metabolic profiling method is established to evaluate the hepatotoxicity of valproic acid and demonstrates proof-of-concept that metabolomic approach with gas chromatography-mass spectrometry has great potential for predicting valproic acid-induced hepatotoxicity and discovering novel biomarkers.

  8. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  9. Comprehensive characterisation of flame retardants in textile furnishings by ambient high resolution mass spectrometry, gas chromatography-mass spectrometry and environmental forensic microscopy.

    Science.gov (United States)

    Ionas, Alin C; Ballesteros Gómez, Ana; Uchida, Natsuyo; Suzuki, Go; Kajiwara, Natsuko; Takata, Kyoko; Takigami, Hidetaka; Leonards, Pim E G; Covaci, Adrian

    2015-10-01

    The presence and levels of flame retardants (FRs), such as polybrominated diphenyl ethers (PBDEs) and organophosphate flame retardants (PFRs), was determined in textile home furnishings, such as carpets and curtains from stores in Belgium. A comprehensive characterisation of FRs in textile was done by ambient high resolution mass spectrometry (qualitative screening), gas chromatography-mass spectrometry (GC-MS) (quantitation), and environmental forensic microscopy (surface distribution). Ambient ionisation coupled to a time-of-flight (TOF) high resolution mass spectrometer (direct probe-TOF-MS) was investigated for the rapid screening of FRs. Direct probe-TOF-MS proved to be useful for a first screening step of textiles to detect FRs below the levels required to impart flame retardancy and to reduce, in this way, the number of samples for further quantitative analysis. Samples were analysed by GC-MS to confirm the results obtained by ambient mass spectrometry and to obtain quantitative information. The levels of PBDEs and PFRs were typically too low to impart flame retardancy. Only high levels of BDE-209 (11-18% by weight) were discovered and investigated in localised hotspots by employing forensic microscopy techniques. Most of the samples were made of polymeric materials known to be inherently flame retarded to some extent, so it is likely that other alternative and halogen-free FR treatments/solutions are preferred for the textiles on the Belgian market.

  10. The composition of volatile components in olivines from Yakutian kimberlites of various ages: Evidence from gas chromatography-mass spectrometry

    Science.gov (United States)

    Tomilenko, A. A.; Bul'bak, T. A.; Khomenko, M. O.; Kuzmin, D. V.; Sobolev, N. V.

    2016-06-01

    The composition of volatiles from fluid and melt inclusions in olivine phenocrysts from Yakutian kimberlite pipes of various ages (Olivinovaya, Malokuonapskaya, and Udachnaya-East) were studied for the first time by gas chromatography-mass spectrometry. It was shown that hydrocarbons and their derivatives, as well as nitrogen-, halogen-, and sulfur-bearing compounds, played a significant role in the mineral formation. The proportion of hydrocarbons and their derivatives in the composition of mantle fluids could reach 99%, including up to 4.9% of chlorineand fluorine-bearing compounds.

  11. Application of capillary gas chromatography mass spectrometry/computer techniques to synoptic survey of organic material in bed sediment

    Science.gov (United States)

    Steinheimer, T.R.; Pereira, W.E.; Johnson, S.M.

    1981-01-01

    A bed sediment sample taken from an area impacted by heavy industrial activity was analyzed for organic compounds of environmental significance. Extraction was effected on a Soxhlet apparatus using a freeze-dried sample. The Soxhlet extract was fractionated by silica gel micro-column adsorption chromatography. Separation and identification of the organic compounds was accomplished by capillary gas chromatography/mass spectrometry techniques. More than 50 compounds were identified; these include saturated hydrocarbons, olefins, aromatic hydrocarbons, alkylated polycyclic aromatic hydrocarbons, and oxygenated compounds such as aldehydes and ketones. The role of bed sediments as a source or sink for organic pollutants is discussed. ?? 1981.

  12. [Progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes].

    Science.gov (United States)

    Wang, Huanhuan; Lu, Yayao; Peng, Bo; Qian, Xiaohong; Zhang, Yangjun

    2015-06-01

    Cytochrome P450 (CYP) enzymes and uridine 5-diphospho-glucuronosyltransferase (UGT) enzymes are critical enzymes for drug metabolism. Both chemical drugs and traditional Chinese medicines are converted to more readily excreted compounds by drug metabolizing enzymes in human livers. Because of the disparate expression of CYP and UGT enzymes among different individuals, accurate quantification of these enzymes is essential for drug pharmacology, drug-drug interactions and drug clinical applications. The research progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes in the recent decade is reviewed.

  13. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats.

    Science.gov (United States)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    2014-04-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared to a control group. Urine samples were collected at day zero, four and eight, and analyzed by HILIC-MS. Multivariate data analysis was applied to the urinary metabolic profiles to identify biochemical variation between the treatment groups. Principal component analysis found a clear distinction between those animals receiving antibiotics and the control animals, with twenty-nine discriminatory compounds of which twenty were down-regulated and nine up-regulated upon treatment. In the treatment group receiving antibiotics for four days, a recovery effect was observed for seven compounds after cessation of antibiotic administration. Thirteen discriminatory compounds could be putatively identified based on their accurate mass, including aconitic acid, benzenediol sulfate, ferulic acid sulfate, hippuric acid, indoxyl sulfate, penicillin G, phenol and vanillin 4-sulfate. The rat urine samples had previously been analyzed by capillary electrophoresis (CE) with MS detection and proton nuclear magnetic resonance ((1)H NMR) spectroscopy. Using CE-MS and (1)H NMR spectroscopy seventeen and twenty-five discriminatory compounds were found, respectively. Both hippuric acid and indoxyl sulfate were detected across all three platforms. Additionally, eight compounds were observed with both HILIC-MS and CE-MS. Overall, HILIC-MS appears to be highly complementary to CE-MS and (1)H NMR spectroscopy, identifying additional compounds that discriminate the urine samples from antibiotic-treated and control rats.

  14. Determination of alcohol sulfates in wastewater treatment plant influents and effluents by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fernández-Ramos, C; Ballesteros, O; Blanc, R; Zafra-Gómez, A; Jiménez-Díaz, I; Navalón, A; Vílchez, J L

    2012-08-30

    In the present paper, we developed an accurate method for the analysis of alcohol sulfates (AS) in wastewater samples from wastewater treatment plant (WWTP) influents and effluents. Although many methodologies have been published in the literature concerning the study of anionic surfactants in environmental samples, at present, the number of analytical methodologies that focus in the determination of AS by gas chromatography in the different environmental compartments is limited. The reason for this is that gas chromatography-mass spectrometry (GC-MS) technique requires a previous hydrolysis reaction followed by derivatization reactions. In the present work, we proposed a new procedure in which the hydrolysis and derivatization reactions take place in one single step and AS are directly converted to trimethylsilyl derivatives. The main factors affecting solid-phase extraction (SPE), hydrolysis/derivatization and GC-MS procedures were accurately optimised. Quantification of the target compounds was performed by using GC-MS in selected ion monitoring (SIM) mode. The limits of detection (LOD) obtained ranged from 0.2 to 0.3 μg L(-1), and limits of quantification (LOQ) from 0.5 to 1.0 μg L(-1), while inter- and intra-day variability was under 5%. A recovery assay was also carried out. Recovery rates for homologues in spiked samples ranged from 96 to 103%. The proposed method was successfully applied for the determination of anionic surfactants in wastewater samples from one WWTP located in Granada (Spain). Concentration levels for the homologues up to 39.4 μg L(-1) in influent and up to 8.1 μg L(-1) in effluent wastewater samples.

  15. Development and validation of a gas chromatography/mass spectrometry method for the assessment of genomic DNA methylation.

    Science.gov (United States)

    Rossella, Federica; Polledri, Elisa; Bollati, Valentina; Baccarelli, Andrea; Fustinoni, Silvia

    2009-09-01

    A method for the determination of DNA global methylation, taken as the ratio (%) of 5-methylcytosine (5mCyt) versus the sum of cytosine (Cyt) and 5mCyt, via gas chromatography/mass spectrometry (GC/MS), was developed and validated. DNA (2.5 microg) was hydrolyzed with aqueous formic acid 88%, spiked with cytosine-2,4-(13)C(2),(15)N(3) and 5-methyl-(2)H(3)-cytosine-6-(2)H(1) as internal standards, and derivatized with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide and 1% tert-butyldimethylchlorosilane, in the presence of acetonitrile and pyridine. GC/MS, operating in single ion monitoring mode, separated and specifically detected all nucleobases as tert-butyldimethylsilyl derivatives, without interferences, with the exception of guanosine. The method was linear throughout the range of clinical interest and had good sensitivity, with a limit of quantification of 3.2 pmol for Cyt and 0.056 pmol for 5mCyt, the latter corresponding to a methylation level of 0.41%. Intra- and inter-day precision and accuracy were below 4.0% for both analytes and methylation. The matrix absolute effect, process efficiency and coefficient of variation ranged from 96.5 to 101.2%. The matrix relative effect was below 1%. The method was applied to the analysis of different human DNAs, including: nonmethylated DNA from PCR (methylation 0.00%), hypermethylated DNA prepared using M.SssI CpG methyltransferase (methylation 18.05%), DNA from peripheral blood leukocytes of healthy subjects (N = 6, median methylation 5.45%), DNA from bone marrow of leukemia patients (N = 5, 3.58%) and DNA from myeloma cell lines (N = 4, 2.74%).

  16. Comparison of four mass analyzers for determining carbosulfan and its metabolites in citrus by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Soler, Carla; Hamilton, Brett; Furey, Ambrose; James, Kevin J; Mañes, Jordi; Picó, Yolanda

    2006-01-01

    Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.

  17. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  18. Development of a thermal desorption-gas chromatography-mass spectrometry method for determining personal care products in air.

    Science.gov (United States)

    Ramírez, Noelia; Marcé, Rosa Maria; Borrull, Francesc

    2010-06-25

    This study describes the development of a new analytical method for determining 14 personal care products (PCPs) - nine synthetic musks, four parabens and one insect repellent - in air samples. The method is based on active sampling on sorbent tubes and thermal desorption-gas chromatography-mass spectrometry analysis, and is rapid, sensitive and drastically reduces the risk of sample contamination. Three kinds of tubes and traps were tested, those filled with Tenax TA being the most suitable for this study. Method validation showed good repeatability and reproducibility, low detection limits (between 0.03 ng m(-3) for DPMI and 12.5 ng m(-3) for propyl paraben) and good linearity for all compounds. Stability during storage indicated that samples must be kept refrigerated at 4 degrees C and analysed within 1 week of collection. The applicability of the technique to real samples was tested in different indoor and outdoor atmospheres. The total PCP values for indoor air ranged from 135 ng m(-3) in a pharmacy to 2838 ng m(-3) in a hairdresser's, whereas the values for outdoor air ranged from 14 ng m(-3) for a suburban environment to 26 ng m(-3) for an urban environment. In general, the most abundant synthetic musks were galaxolide (5.9-1256 ng m(-3)), musk xylene (1.6-766 ng m(-3)) and tonalide (1.1-138 ng m(-3)). Methyl and ethyl paraben (2.4-313 ng m(-3) and 1.8-117 ng m(-3), respectively) were the most abundant parabens. Although thermal desorption methods have been widely used for determining volatile organic compounds, they are rarely used with semi-volatile compounds. This study thus demonstrates that the thermal desorption method performs well with semi-volatile compounds and, for the first time, that it can be used for determining PCPs.

  19. Metabolic Profiling with Gas Chromatography-Mass Spectrometry and Capillary Electrophoresis-Mass Spectrometry Reveals the Carbon-Nitrogen Status of Tobacco Leaves Across Different Planting Areas.

    Science.gov (United States)

    Zhao, Jieyu; Zhao, Yanni; Hu, Chunxiu; Zhao, Chunxia; Zhang, Junjie; Li, Lili; Zeng, Jun; Peng, Xiaojun; Lu, Xin; Xu, Guowang

    2016-02-05

    The interaction between carbon (C) and nitrogen (N) metabolism can reflect plant growth status and environmental factors. Little is known regarding the connections between C-N metabolism and growing regions under field conditions. To comprehensively investigate the relationship in mature tobacco leaves, we established metabolomics approaches based on gas chromatography-mass spectrometry (GC-MS) and capillary electrophoresis-time-of-flight-mass spectrometry (CE-TOF-MS). Approximately 240 polar metabolites were determined. Multivariate statistical analysis revealed that the growing region greatly influenced the metabolic profiles of tobacco leaves. A metabolic correlation network and related pathway maps were used to reveal the global overview of the alteration of C-N metabolism across three typical regions. In Yunnan, sugars and tricarboxylic acid (TCA) cycle intermediates were closely correlated with amino acid pools. Henan tobacco leaves showed positive correlation between the pentose phosphate pathway (PPP) intermediates and C-rich secondary metabolism. In Guizhou, the proline and asparagine had significant links with TCA cycle intermediates and urea cycle, and antioxidant accumulation was observed in response to drought. These results demonstrate that combined analytical approaches have great potential to detect polar metabolites and provide information on C-N metabolism related to planting regional characteristics.

  20. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China); Shen Jianzhong, E-mail: sjz@cau.edu.cn [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China)

    2009-10-05

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 {mu}g kg{sup -1}, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  1. Application of Pyrolysis Gas Chromatography/Mass Spectrometry in Lacquer Research: A Review

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Ma

    2014-01-01

    Full Text Available Examination of thermal degradation of natural and synthetic lacquer films by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS is reviewed. Due to the instantaneous heating decomposition, side reactions of internal or intermediate samples hardly occur, and the pyrolysis products can be retrieved without any change. Py-GC/MS has been used to analyze the composition of insoluble polymers and investigate degradation of resin materials. Lacquer film is a cross-linked polymer that is insoluble in any solvent. The aim of this review is to describe the application of Py-GC/MS to the analysis of lacquer, including natural lacquer saps, synthetic lacquer derivatives, and their films. After analyzing the chemical structures of the specific pyrolysis products by mass spectrometry, the lacquer tree species and growing region can be determined. These results have great significance for the protection and restoration of lacquer-coated cultural treasures.

  2. Analysis of Organic Molecules Extracted from Mars Analogues and Influence of Their Mineralogy Using N-Methyl-N-(tert-butyldimethylsilyl)Trifluoroacetamide Derivatization Coupled with Gas Chromatography Mass Spectrometry in Preparation for the Sample Analysis at Mars Derivatization Experiment on the Mars Science Laboratory Mission

    Science.gov (United States)

    Stalport, F.; Glavin, D. P.; Eigenbrode, J. L.; Bish, D.; Blake, D.; Coll, P.; Szopa, C.; Buch, A.; McAdam, A.; Dworkin, J. P.; Mahaffy, P. R.

    2012-01-01

    The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids will require a chemical extraction and derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed, a one-pot extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment on the Mars Science Laboratory (MSL). The temperature and duration the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 C for several minutes of a variety of terrestrial Mars analogue materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analogue materials that contained high abundances of hydrated minerals and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA, The combination of pyrolysis and two different chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars,

  3. Rapid Preconcentration for Liquid Chromatography-Mass Spectrometry Assay of Trace Level Neuropeptides

    Science.gov (United States)

    Zhou, Ying; Mabrouk, Omar S.; Kennedy, Robert T.

    2013-11-01

    Measurement of neuropeptides in the brain through in vivo microdialysis sampling provides direct correlation between neuropeptide concentration and brain function. Capillary liquid chromatography-multistage mass spectrometry (CLC-MSn) has proven to be effective at measuring endogenous neuropeptides in microdialysis samples. In the method, microliter samples are concentrated onto nanoliter volume packed beds before ionization and mass spectrometry analysis. The long times required for extensive preconcentration present a barrier to routine use because of the many samples that must be analyzed and instability of neuropeptides. In this study, we evaluated the capacity of 75 μm inner diameter (i.d.) capillary column packed with 10 μm reversed phase particles for increasing the throughput in CLC-MSn based neuropeptide measurement. Coupling a high injection flow rate for fast sample loading/desalting with a low elution flow rate to maintain detection sensitivity, this column has reduced analysis time from ˜30 min to 3.8 min for 5 μL sample, with 3 pM limit of detection (LOD) for enkephalins and 10 pM LOD for dynorphin A1-8 in 5 μL sample. The use of isotope-labeled internal standard lowered peptide signal variation to less than 5 %. This method was validated for in vivo detection of Leu and Met enkephalin with microdialysate collected from rat globus pallidus. The improvement in speed and stability makes CLC-MSn measurement of neuropeptides in vivo more practical.

  4. Seasonal variations of particle-associated nitrosamines by gas chromatography-mass spectrometry in the atmospheric environment of Zonguldak, Turkey.

    Science.gov (United States)

    Akyüz, Mehmet; Ata, Şevket

    2013-10-01

    A gas chromatography-mass spectrometry method has been proposed for the determination of low-level mutagenic and carcinogenic nitrosamines in particulate matter. The method includes the collection of particulate matters (PM2.5 and PM10) using a dichotomous Partisol 2025 sampler and extraction of the compounds from aqueous solution with dichloromethane/2-propanol after sonication with a slightly basic water solution prior to their GC-MS analysis in electron impact mode. The obtained recoveries of nitrosamines ranged from 92.4 to 99.2 %, and the precision of this method, as indicated by the relative standard deviations, was within the range of 0.95-2.46 %. The detection limits obtained from calculations using the GC-MS results based on S/N=3 were found within the range from 4 to 22 pg/m(3). The predominant nitrosamines determined in particulate matter were N-nitrosodimethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine and N-nitrosomorpholine. Furthermore, N-mono- and dinitrosopiperazine and N-nitrosoethylbutylamine were also determined. N-dinitrosopiperazine was detected in PM2.5 samples at the highest concentrations of up to 22.85 ng/m(3) and in PM2.5-10 samples at concentrations up to 7.60 ng/m(3) in winter, whereas it was found in PM2.5 samples up to 5.15 ng/m(3) and in PM2.5-10 samples up to 3.12 ng/m(3) in summer. The total concentrations of nitrosamines were up to 161.4 ng/m(3) in fine and 53.90 ng/m(3) in coarse fractions in winter, whereas in summer were up to 35.24 and 12.60 ng/m(3), respectively. The concentration levels of nitrosamines fluctuated significantly within a year, with higher means and peak concentrations in the winter compared to that in the summertime. The seasonal variations of particle-associated nitrosamine concentrations were investigated together with their relationships with meteorological parameters using Pearson's correlation analysis in the winter and summer periods. Analysis of variance was used to determine which

  5. Monitoring the ripening process of Cheddar cheese based on hydrophilic component profiling using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ochi, H; Sakai, Y; Koishihara, H; Abe, F; Bamba, T; Fukusaki, E

    2013-01-01

    We proposed an application methodology that combines metabolic profiling with multiple appropriate multivariate analyses and verified it on the industrial scale of the ripening process of Cheddar cheese to make practical use of hydrophilic low-molecular-weight compound profiling using gas chromatography-mass spectrometry to design optimal conditions and quality monitoring of the cheese ripening process. Principal components analysis provided an overview of the effect of sodium chloride content and kind of lactic acid bacteria starter on the metabolic profile in the ripening process of Cheddar cheese and orthogonal partial least squares-discriminant analysis unveiled the difference in characteristic metabolites. When the sodium chloride contents were different (1.6 and 0.2%) but the same lactic acid bacteria starter was used, the 2 cheeses were classified by orthogonal partial least squares-discriminant analysis from their metabolic profiles, but were not given perfect discrimination. Not much difference existed in the metabolic profile between the 2 cheeses. Compounds including lactose, galactose, lactic acid, 4-aminobutyric acid, and phosphate were identified as contents that differed between the 2 cheeses. On the other hand, in the case of the same salt content of 1.6%, but different kinds of lactic acid bacteria starter, an excellent distinctive discrimination model was obtained, which showed that the difference of lactic acid bacteria starter caused an obvious difference in metabolic profiles. Compounds including lactic acid, lactose, urea, 4-aminobutyric acid, galactose, phosphate, proline, isoleucine, glycine, alanine, lysine, leucine, valine, and pyroglutamic acid were identified as contents that differed between the 2 cheeses. Then, a good sensory prediction model for "rich flavor," which was defined as "thick and rich, including umami taste and soy sauce-like flavor," was constructed based on the metabolic profile during ripening using partial least

  6. Determination of five abused drugs in nitrite-adulterated urine by immunoassays and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsai, S C; ElSohly, M A; Dubrovsky, T; Twarowska, B; Towt, J; Salamone, S J

    1998-10-01

    The adulteration of urine specimens with nitrite ion hasseen shown to mask the gas chromatography-mass spectrometry (GC-MS) confirmation testing of marijuana use. This study was designed to further investigate the effect of nitrite adulteration on the detection of five commonly abused drugs by immunoassay screening and GC-MS analysis. The drugs tested are cocaine metabolite (benzoylecgonine), morphine, 11-nor-delta-tetrahydrocannabinol-9-carboxylic acid (THCCOOH), amphetamine, and phencyclidine. The immunoassays evaluated included the instrument-based Abuscreen ONLINE assays, the on-site Abuscreen ONTRAK assays, and the one-step ONTRAK TESTCUP-5 assay. Multianalyte standards containing various levels of drugs were used to test the influence of both potassium and sodium nitrite. In the ONLINE immunoassays, the presence of up to 1.0M nitrite in the multianalyte standards had no significant effect for benzoylecgonine, morphine, and phencyclidine assays. With a high concentration of nitrite, ONLINE became more sensitive for amphetamine (detected more drug than what was expected) and less sensitive for THCCOOH (detected less drug than what was expected). No effects of nitrite were observed on the results of the Abuscreen ONTRAK assays. Similarly, no effects were observed on the absolute qualitative results of the TESTCUP-5 when testing the nitrite-adulterated standards. However, the produced intensities of the signals that indicate the negative test results were slightly lowered in the THC and phencyclidine assays. The presence of 1.0M of nitrite did not show dramatic interference with the GC-MS analysis of benzoylecgonine, morphine, amphetamine, and phencyclidine. In contrast, nitrite ion significantly interfered with the detection of THCCOOH by GC-MS. The presence of 0.03M of nitrite ion resulted in significant loss in the recovery of THCCOOH and its internal standard by GC-MS. The problem of nitrite adulteration could be alleviated by sodium bisulfite treatment even

  7. Coordinating fingerprint determination of solid-phase microextraction/gas chromatography-mass spectrometry and chemometric methods for quality control of oxidized tallow.

    Science.gov (United States)

    Song, Shiqing; Zhang, Xiaoming; Hayat, Khizar; Xiao, Zuobing; Niu, Yunwei; Eric, Karangwa

    2013-02-22

    Based on optimized solid-phase microextraction/gas chromatography-mass spectrometry (SPME/GC-MS) and chemometric methods, simple, reliable and reproducible methods were described for the first time for developing a chromatographic fingerprint of oxidized tallow. Eight optimal oxidized tallow samples were used to establish the chromatographic fingerprint. Spectral correlative chromatogram was adopted to identify 33 "common components". The validation of fingerprint analysis was performed based on the relative retention time, the relative peak area of common peaks, sample stability and similarity analysis. The correlation coefficient of similarity of eight optimal oxidized tallow samples was more than 0.962, which showed that samples from different batches were consistent to some extent in spite of slightly different chemical indexes. Through principal component analysis (PCA), 14 constituents were further screened out to be the main chemical markers, which could be applied to more accurate quantitative discrimination and quality control of oxidized tallow.

  8. Analysis of the chemical composition of the essential oils extracted from Lippia lacunosa Mart. and Schauer and Lippia rotundifolia Cham. (Verbenaceae) by gas chromatography and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Suzana G.; Barbosa, Ymira Galico [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Fac. de Farmacia; Oliveira, Danilo R. de; Leitao, Gilda G. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Nucleo de Pesquisas de Produtos Naturais]. E-mail: sgleitao@pharma.ufrj.br; Suelsen, Valeria; Martino, Virginia [Universidad de Buenos Aires (Argentina). Facultad de Farmacia y Bioquimica; Bizzo, Humberto R.; Lopes, Daise [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil); Viccini, Lyderson F.; Salimena, Fatima R.G.; Peixoto, Paulo H.P. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Inst. de Ciencias Biolgicas

    2008-07-01

    Lippia lacunosa and L. rotundifolia (Verbenaceae) are two Brazilian species of complex taxonomic delimitation. The composition of the essential oils from leaves and flowers of these plants was investigated by gas chromatography (GC) and gas chromatography coupled with mass spectrometry (GC-MS) analysis. The major components of the essential oils of flowers and leaves of L. lacunosa were: myrcene (14.7% and 11.9%), myrcenone (45.2% and 64.2%), Z-ocimenone (5.7% and 5.2%), and E-ocimenone (14.7% and 4.1%), respectively; whereas in L. rotundifolia (flowers and leaves) were ..-pinene (8.7% and 1.8%), myrcene (5.1% and 3.6%), limonene (26.0% and 7.9 %), cis-pinocamphone (4.5% and 3.1%) and myrtenal (22.3% and 16.7%), respectively. The essential oils from L. lacunosa exhibited a strong and pleasant mango aroma, which was related to the presence of myrcene and myrcenone. The marked differences in the chemical composition of their essential oils may represent a powerful tool for the botanical classification. (author)

  9. Volatile constituents of Murraya koenigii fresh leaves using headspace solid phase microextraction--gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sukkaew, Sayamol; Pripdeevech, Patcharee; Thongpoon, Chalermporn; Machan, Theeraphan; Wongchuphan, Rattana

    2014-12-01

    The volatile components of Murraya koenigii fresh leaves, collected from Surat Thani province, Thailand were studied by using headspace (HS) solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS). The four fibers employed to extract the volatiles were polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), carboxane-polydimethylsiloxane (CAR-PDMS) and polydimethylsiloxane-divinylbenzene-carboxane (PDMS-DVB-CAR). The volatile constituents of M. koenigii fresh leaves were also extracted by hydrodistillation and analyzed by GC-MS. Fifty-one compounds were identified by these fibers. Five major compounds, γ-terpinene, β-caryophyllene, β-phellandrene, a-selinene and a-pinene, were detected in all fibers. The PDMS-DVB-CAR fiber was considered as the best for trapping key volatiles of M. koenigii fresh leaves.

  10. Determination of benzene in soft drinks and other beverages by isotope dilution headspace gas chromatography/mass spectrometry.

    Science.gov (United States)

    Cao, Xu-Liang; Casey, Valerie; Seaman, Steve; Tague, Brett; Becalski, Adam

    2007-01-01

    An automated, simple, and reproducible method was developed for the determination of benzene in soft drinks, based on isotope dilution headspace gas chromatography/mass spectrometry in the selected-ion monitoring mode. The method was used to assess benzene levels in samples of 124 soft drinks and beverages. Benzene was not detected in 60% of the 124 products. The average benzene levels in 6 products exceeded the Canadian maximum acceptable concentration of 5 microg/L for benzene in drinking water, and 2 of the 6 products had benzene levels above the World Health Organization guideline of 10 microg/L. The highest level of benzene, 23 microg/L, was found in a soft drink product specifically marketed to children.

  11. [Determination of chemical components of volatile oil from Cuminum cyminum L. by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Yan, Jian-hui; Tang, Ke-wen; Zhong, Ming; Deng, Ning-hua

    2002-11-01

    Volatile oil was extracted from Cuminum cyminum L. by using steam distillation. More than sixty peaks were separated and 49 compounds were identified by gas chromatography-mass spectrometry (GC-MS). The relative amounts of the components were determined by area normalization method. Among the 49 compounds identified, there were 16 hydrocarbons and 32 oxygenated compounds. The main compnents were cuminal and safranal (accounting for 32.26% and 24.46% respectively in the components identified). The other nine compounds with contents all over 1%, were monterpenes, sesquiterpenes, aromatic aldehydes and aromatic oxides etc. The other components with relatively small amounts were chiefly terpenes, terpenols, terpenals, terpenones, terpene esters and aromatic compounds. It is good to separate polar and apolar components in the volatile oil from Cuminum cyminum L. on the GC capillary column of moderate polarity.

  12. Measurement uncertainty for the determination of amphetamines in urine by liquid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Franco de Oliveira, Sarah Carobini Werner de Souza Eller; Yonamine, Mauricio

    2016-08-01

    A gas chromatography-mass spectrometry method for the determination of amphetamines in urine samples by means of liquid-phase microextraction was validated, including calculation of measurement uncertainty. After extraction in the three-phase mode, acceptor phase was withdrawn from the fiber and the residue was derivatized with trifluoroacetic anhydride. The method showed to be very simple, rapid and it required a significantly low amount of organic solvent for extraction. The limits of detection were 10 and 20μg/L for amphetamine and methamphetamine, respectively. The calibration curves were linear over the specified range (20μg/L to 1400μg/L; r(2)>0.99). The method showed to be both precise and accurate and a relative combined uncertainty of 2% was calculated. In order of importance, the factors which were more determinant for the calculation of method uncertainty were: analyte concentration, sample volume, trueness and method precision.

  13. Analyzing salvia divinorum and its active ingredient salvinorin a utilizing thin layer chromatography and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Jermain, John D; Evans, Hiram K

    2009-05-01

    In recent years, Salvia divinorum has become a major focus by state legislatures throughout the United States looking to prohibit the sale of the psychoactive plant. After researching testing procedures presented in the literature and those employed by crime laboratories throughout the country, it was decided that thin layer chromatography (TLC) and gas chromatography/mass spectrometry (GC/MS) were the methods to use to analyze plant material for salvinorin A. With TLC, salvinorin A was detected from extracted plant material and was easily distinguishable from 13 other Salvia species as well as Cannabis sativa L. (marijuana). When using GC/MS, salvinorin A was best extracted from plant material with chloroform at ambient temperature when using a nonpolar solvent and acetone at ambient temperature when using a polar solvent. By utilizing these techniques, criminalists are now able to confirm the presence of salvinorin A in a submitted plant material suspected to be Salvia divinorum.

  14. Application of Gas Chromatography-mass Spectrometry in Analyzing Pharmacokinetics and Distribution of Deltamethrin in Miniature Pig Tissues

    Institute of Scientific and Technical Information of China (English)

    ZHU Pan; FAN Sai; ZOU Jian Hong; MIAO Hong; LI Jing Guang; ZHANG Guo Wen; WU Yong Ning

    2014-01-01

    Objective To characterize the pharmacokinetics and distribution profiles of deltamethrin in miniature pig tissues by gas chromatography-mass spectrometry (GC-MS). Methods Pharmacokinetics and distribution of deltamethrin in blood and tissues of 30 miniature pigs were studied by GC-MS after oral administration of deltamethrin (5 mg/kg bw). Data were processed by 3P97 software. Results The serum deltamethrin level was significantly lower in tissues than in blood of miniature pigs. The AUC0-72 h, Cmax, of deltamethrin were 555.330±316.987 ng h/mL and 17.861±11.129 ng/mL, respectively. The Tmax, of deltamethrin was 6.004±3.131 h. Conclusion The metabolism of deltamethrin in miniature pigs is fit for a one-compartment model with a weighting function of 1/C2. Deltamethrin is rapidly hydrolyzed and accumulated in miniature pig tissues.

  15. The future of liquid chromatography-mass spectrometry in metabolic profiling and metabolomic studies for biomarker discovery.

    Energy Technology Data Exchange (ETDEWEB)

    Metz, Thomas O.; Zhang, Qibin; Page, Jason S.; Shen, Yufeng; Callister, Stephen J.; Jacobs, Jon M.; Smith, Richard D.

    2007-06-01

    The future utility of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discover will be discussed, beginning with a brief description of the evolution of metabolomics and the utilization of the three most popular analytical platforms in such studies: NMR, GC-MS, and LC-MS. Emphasis is placed on recent developments in high-efficiency LC separations and sensitive electrospray ionization approaches and the benefits to incorporating both in LC-MS-based approaches. The advantages and disadvantages of various quantitative approaches are reviewed, followed by the current LC-MS-based tools available for candidate biomarker characterization and identification. Finally, a brief prediction on the future path of LC-MS-based methods in metabolic profiling and metabolomic studies is given.

  16. [Metabonomics study of lung cancer cells based on liquid l chromatography-mass spectrometry].

    Science.gov (United States)

    Yu, Xinwei; Wu, Qian; Lu, Wang; Wang, Yan; Ma, Xiaoqiong; Chen, Zhe; Yan, Chao

    2013-07-01

    The metabolic profiles of the polar metabolites and the non-polar metabolites in lung tumor cell lines H358, A549, HCC827, H1299, Calu-3, Calu-l, PC-9 and normal cell line MRC-5 were analyzed separately using high performance liquid chromatography-quadrupole time-of flight mass spectrometry (HPLC-Q-TOF/MS). Partial least square discriminant analysis ( PLS-DA) was used to process the metabolic data. The results showed that the metabolites of the lung cancer cell lines and normal cell line have significant differences. Further, 10 polar metabolites and 21 non-polar metabolites which had a significant contribution to classification were selected and preliminarily identified due to the accurate mass. Comparing with the normal cell line, the lung tumor cell lines present an abnormal metabolism in protein, fatty acid, and phospholipids. These results may provide important information for the early diagnosis of lung cancer.

  17. Coal liquefaction process streams characterization and evaluation. Characterization of coal-derived materials by field desorption mass spectrometry, two-dimensional nuclear magnetic resonance, supercritical fluid extraction, and supercritical fluid chromatography/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Linehan, J.C.; Robins, W.H. [Battelle Pacific Northwest Lab., Richland, WA (United States)

    1992-07-01

    Under contract from the DOE , and in association with CONSOL Inc., Battelle, Pacific Northwest Laboratory (PNL) evaluated four principal and several complementary techniques for the analysis of non-distillable direct coal liquefaction materials in support of process development. Field desorption mass spectrometry (FDMS) and nuclear magnetic resonance (NMR) spectroscopic methods were examined for potential usefulness as techniques to elucidate the chemical structure of residual (nondistillable) direct coal liquefaction derived materials. Supercritical fluid extraction (SFE) and supercritical fluid chromatography/mass spectrometry (SFC/MS) were evaluated for effectiveness in compound-class separation and identification of residual materials. Liquid chromatography (including microcolumn) separation techniques, gas chromatography/mass spectrometry (GC/MS), mass spectrometry/mass spectrometry (MS/MS), and GC/Fourier transform infrared (FTIR) spectroscopy methods were applied to supercritical fluid extracts. The full report authored by the PNL researchers is presented here. The following assessment briefly highlights the major findings of the project, and evaluates the potential of the methods for application to coal liquefaction materials. These results will be incorporated by CONSOL into a general overview of the application of novel analytical techniques to coal-derived materials at the conclusion of CONSOL`s contract.

  18. Development and application of a method for analysis of lufenuron in wheat flour by gas chromatography-mass spectrometry and confirmation of bio-efficacy against Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae).

    Science.gov (United States)

    Ahire, Kedar C; Arora, Manjit S; Mukherjee, Samindra N

    2008-01-01

    A new analytical method using gas chromatography with mass spectrometry (GC-MS) for the quantitative determination of lufenuron, a benzoylphenylurea (BPU) class of insecticide, from wheat flour has been developed and applied for time-dependent residue monitoring in treated wheat flour. The analyte was extracted from wheat flour by a single step solid-liquid extraction by using ethyl acetate and subsequently cleaned up using the Primary Secondary Amine as a sorbent prior to GC-MS analysis. The present method provides sufficient sensitivity as reflected by the values of limit of detection (LOD) and limit of quantification (LOQ), 5 ng/mL (S/N approximately 3) and 50 ng/mL (the lowest validation point on the calibration curve), respectively. The calibration curve showed an excellent linearity in the concentration range of 50-1000 ng/mL (r2=0.998). The average recovery for spiked samples at three concentrations (150, 300, and 450 ng/g) was 98.23+/-2.52% R.S.D. The method was applied for the determination of lufenuron residues in treated wheat flour samples. Simultaneous determination of bio-efficacy of lufenuron residues was also carried out against the red flour beetle, Tribolium castaneum to correlate the actual residual effect of lufenuron as detected by the analytical method, over a period of 3 months. The findings revealed that the residual concentration of lufenuron were neither uniform nor in descending order over a period of 3 months in wheat flour, possibly because of an uneven dispersal in the treated wheat which was subsequently milled into flour, as confirmed by GC-MS analysis. However, the residues of lufenuron were sufficient to produce 100% mortality of T. castaneum larvae up to 3 months. The results have been discussed in view of the potential of lufenuron as a candidate molecule for the control of stored product pests.

  19. Comparison of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry with electron ionization for determination of N-nitrosamines in environmental water.

    Science.gov (United States)

    Chen, Wenwen; Li, Xiaoshui; Huang, Huanfang; Zhu, Xuetao; Jiang, Xiaoyu; Zhang, Yuan; Cen, Kuang; Zhao, Lunshan; Liu, Xiuli; Qi, Shihua

    2017-02-01

    N-nitrosamines are trace organic contaminants of environmental concern when present in groundwater and river water due to their potent carcinogenicity. Therefore, N-nitrosamine analysis is increasingly in demand. Gas chromatography-mass spectrometry (GC-MS) and GC-tandem mass spectrometry (GC-MS/MS), both with electron ionization (EI), were compared for analysis of nine N-nitrosamines extracted from environmental water matrices. A total of 20 fishpond water, river water, and groundwater samples from Sihui and Shunde, China were collected for a survey of N-nitrosamine concentrations in real water samples. Various solid-phase extraction (SPE) conditions and GC conditions were first examined for the pre-concentration and separation steps. The analysis of N-nitrosamines in environmental waters demonstrated that their quantification with GC-MS poses a challenge due to the occurrence of co-eluting interferences. Conversely, the use of GC-MS/MS increased selectivity because of the fragmentation generated from precursor ions in the 'multiple reaction monitoring' (MRM) mode, which is expected to extract target analytes from the environmental water matrix. Thus, the high performance of GC-MS/MS with EI was used to quantify nine N-nitrosamines in environmental waters with detection limits of 1.1-3.1 ng L(-1). N-nitrosodimethylamine (NDMA) concentrations were in the range of N.D. to 258 ng L(-1). Furthermore, other N-nitrosamines, except N-nitrosomethylethylamine (NMEA), N-nitroso-di-n-propylamine (NDPA) and N-nitrosopiperidine (NPIP), were also detected. Our findings suggest that GC-MS/MS with EI would be widely applicable in identifying N-nitrosamines in environmental waters and can be used for routine monitoring of these chemicals.

  20. Prediction of Gas Chromatography-Mass Spectrometry Retention Times of Pesticide Residues by Chemometrics Methods

    Directory of Open Access Journals (Sweden)

    Elaheh Konoz

    2013-01-01

    Full Text Available A quantitative structure-retention relationships (QSRRs method is employed to predict the retention time of 300 pesticide residues in animal tissues separated by gas chromatography-mass spectroscopy (GC-MS. Firstly, a six-parameter QSRR model was developed by means of multiple linear regression. The six molecular descriptors that were considered to account for the effect of molecular structure on the retention time are number of nitrogen, Solvation connectivity index-chi 1, Balaban Y index, Moran autocorrelation-lag 2/weighted by atomic Sanderson electronegativity, total absolute charge, and radial distribution function-6.0/unweighted. A 6-7-1 back propagation artificial neural network (ANN was used to improve the accuracy of the constructed model. The standard error values of ANN model for training, test, and validation sets are 1.559, 1.517, and 1.249, respectively, which are less than those obtained reveals by multiple linear regressions model (2.402, 1.858, and 2.036, resp.. Results obtained the reliability and good predictability of nonlinear QSRR model to predict the retention time of pesticides.

  1. An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kim Seongho

    2011-10-01

    Full Text Available Abstract Background Mass spectrometry (MS based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS. Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. Results With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. Conclusions We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http

  2. Development and validation of a solid-phase extraction method using anion exchange sorbent for the analysis of cannabinoids in plasma and serum by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga; Schürenkamp, Jennifer

    2016-07-01

    The aim of this work was to develop and validate a solid-phase extraction (SPE) method for the analysis of cannabinoids with emphasis on a very extensive and effective matrix reduction in order to ensure constant good results in selectivity and sensitivity regardless of the applied measuring technology. This was obtained by the use of an anion exchange sorbent (AXS) and the purposive ionic interaction between matrix components and this sorbent material. In a first step, the neutral cannabinoids ∆9-tetrahydrocannabinol (THC) and 11-hydroxy-∆9-tetrahydrocannabinol (11-OH-THC) were eluted, leaving 11-nor-9-carboxy-∆9-tetrahydrocannabinol (THC-COOH) and the main interfering matrix components bound to the AXS. In a second step, exploiting differences in pH and polarity, it was possible to separate matrix components and THC-COOH, thereby yielding a clean elution of THC-COOH into the same collecting tube as THC and 11-OH-THC. Even when using a simple measuring technology like gas chromatography with single quadrupole mass spectrometry, this two-step elution allows for an obvious decrease in number and intensity of matrix interference in the chromatogram. Hence, in both plasma and serum, the AXS extracts resulted in very good selectivity. Limits of detection and limits of quantification were below 0.25 and 0.35 ng/mL for the neutral cannabinoids in both matrices, 2.0 and 3.0 ng/mL in plasma and 1.6 and 3.3 ng/mL in serum for THC-COOH. The recoveries were ≥79.8 % for all analytes. Interday and intraday imprecisions ranged from 0.8 to 6.1 % relative standard deviation, and accuracy bias ranged from -12.6 to 3.6 %.

  3. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  4. Full evaporation dynamic headspace and gas chromatography-mass spectrometry for uniform enrichment of odor compounds in aqueous samples.

    Science.gov (United States)

    Ochiai, Nobuo; Sasamoto, Kikuo; Hoffmann, Andreas; Okanoya, Kazunori

    2012-06-01

    A method for analysis of a wide range of odor compounds in aqueous samples at sub-ng mL⁻¹ to μg mL⁻¹ levels was developed by full evaporation dynamic headspace (FEDHS) and gas chromatography-mass spectrometry (GC-MS). Compared to conventional DHS and headspace solid phase microextraction (HS-SPME), FEDHS provides more uniform enrichment over the entire polarity range for odor compounds in aqueous samples. FEDHS at 80°C using 3 L of purge gas allows complete vaporization of 100 μL of an aqueous sample, and trapping and drying it in an adsorbent packed tube, while providing high recoveries (85-103%) of the 18 model odor compounds (water solubility at 25°C: log0.54-5.65 mg L⁻¹, vapor pressure at 25°C: 0.011-3.2 mm Hg) and leaving most of the low volatile matrix behind. The FEDHS-GC-MS method showed good linearity (r²>0.9909) and high sensitivity (limit of detection: 0.21-5.2 ng mL⁻¹) for the model compounds even with the scan mode in the conventional MS. The feasibility and benefit of the method was demonstrated with analyses of key odor compounds including hydrophilic and less volatile characteristics in beverages (whiskey and green tea). In a single malt whiskey sample, phenolic compounds including vanillin could be determined in the range of 0.92-5.1 μg mL⁻¹ (RSD<7.4%, n=6). For a Japanese green tea sample, 48 compounds including 19 potent odorants were positively identified from only 100 μL of sample. Heat-induced artifact formation for potent odorants was also examined and the proposed method does not affect the additional formation of thermally generated compounds. Eighteen compounds including 12 potent odorants (e.g. coumarin, furaneol, indole, maltol, and pyrazine congeners) were determined in the range of 0.21-110 ng mL⁻¹ (RSD<10%, n=6).

  5. Determination of "new psychoactive substances" in postmortem matrices using microwave derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Margalho, Cláudia; Castanheira, Alice; Real, Francisco Corte; Gallardo, Eugenia; López-Rivadulla, Manuel

    2016-05-01

    Despite worldwide efforts aiming to ban the marketing and subsequent abuse of psychoactive substances such as synthetic cathinones and phenethylamines, there has been an alarming growth of both in recent years. Different compounds similar to those already existing are continuously appearing in the market in order to circumvent the legislation. An analytical methodology has been validated for qualitative and quantitative determinations of D-cathine (D-norpseudoehedrine), ephedrine, methcathinone, 1-(4-methoxyphenyl)-propan-2-amine (PMA), mephedrone, methedrone, 2,5-dimethoxy-4-methylamphetamine (DOM), 4-bromo-2,5-dimethoxyamphetamine (DOB), 2,5-dimethoxyphenethylamine (2C-H), 4-bromo-2,5-dimethoxyphenethylamine (2C-B), 4-iodo-2,5-dimethoxyphenethylamine (2C-I), 2-[2,5-dimethoxy-4-(ethylthio)phenyl]ethanamine (2C-T-2), 2,5-dimethoxy-4-isopropylthiophenethylamine (2C-T-4) and 2-[2,5-dimethoxy-4-(propylthio)phenyl]ethanamine (2C-T-7), in low volumes of vitreous humor (100 μL), pericardial fluid (250 μL) and whole blood (250 μL), using deutered amphetamine, ephedrine and mephedrone as internal standards. The validation parameters included selectivity, linearity and limits of detection and quantification, intra- and interday precision and trueness, recovery and stability. The method included mixed-mode solid phase extraction, followed by microwave fast derivatization and analysis by gas chromatography-mass spectrometry operated in selected ion monitoring mode. The procedure was linear between 5 and 600 ng/mL, with determination coefficients higher than 0.99 for all analytes. Intra- and interday precision ranged from 0.1 to 13.6%, while accuracy variability was within 80-120% interval from the nominal concentration at all studied levels. The extraction efficiencies ranged from 76.6 to 112.8%. Stability was considered acceptable for all compounds in the studied matrices. The developed assay was applied to authentic samples of the Laboratory of Chemistry and Forensic

  6. Gas chromatography/mass spectrometry based component profiling and quality prediction for Japanese sake.

    Science.gov (United States)

    Mimura, Natsuki; Isogai, Atsuko; Iwashita, Kazuhiro; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-10-01

    Sake is a Japanese traditional alcoholic beverage, which is produced by simultaneous saccharification and alcohol fermentation of polished and steamed rice by Aspergillus oryzae and Saccharomyces cerevisiae. About 300 compounds have been identified in sake, and the contribution of individual components to the sake flavor has been examined at the same time. However, only a few compounds could explain the characteristics alone and most of the attributes still remain unclear. The purpose of this study was to examine the relationship between the component profile and the attributes of sake. Gas chromatography coupled with mass spectrometry (GC/MS)-based non-targeted analysis was employed to obtain the low molecular weight component profile of Japanese sake including both nonvolatile and volatile compounds. Sake attributes and overall quality were assessed by analytical descriptive sensory test and the prediction model of the sensory score from the component profile was constructed by means of orthogonal projections to latent structures (OPLS) regression analysis. Our results showed that 12 sake attributes [ginjo-ka (aroma of premium ginjo sake), grassy/aldehydic odor, sweet aroma/caramel/burnt odor, sulfury odor, sour taste, umami, bitter taste, body, amakara (dryness), aftertaste, pungent/smoothness and appearance] and overall quality were accurately explained by component profiles. In addition, we were able to select statistically significant components according to variable importance on projection (VIP). Our methodology clarified the correlation between sake attribute and 200 low molecular components and presented the importance of each component thus, providing new insights to the flavor study of sake.

  7. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  8. Prediction of Molar Extinction Coefficients of Proteins and Peptides Using UV Absorption of the Constituent Amino Acids at 214 nm To Enable Quantitative Reverse Phase High-Performance Liquid Chromatography-Mass Spectrometry Analysis

    NARCIS (Netherlands)

    Kuipers, B.J.H.; Gruppen, H.

    2007-01-01

    The molar extinction coefficients of 20 amino acids and the peptide bond were measured at 214 nm in the presence of acetonitrile and formic acid to enable quantitative comparison of peptides eluting from reversed-phase high-performance liquid chromatography, once identified with mass spectrometry (R

  9. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn M.

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  10. Identification of intact long-chain p-hydroxycinnamate esters in leaf fibers of abaca (Musa textilis) using gas chromatography/mass spectrometry.

    Science.gov (United States)

    del Río, José C; Rodríguez, Isabel M; Gutiérrez, Ana

    2004-01-01

    The study of acetone-extractable components from the leaf fibers of the non-wood plant abaca (Musa textilis) resulted in the isolation and identification of series of intact hydroxycinnamate esters consisting of ferulic and p-coumaric acids esterified to long-chain fatty alcohols (C20 to C28) and omega-hydroxyfatty acids (C22 to C28). These series of compounds were characterized by high-temperature gas chromatography/mass spectrometry (GC/MS) using capillary columns (12 m length) with thin films that allowed the analysis of intact (i.e., without prior saponification) hydroxycinnamate esters. Characterization of intact individual compounds was achieved based on the mass spectra obtained by GC/MS of the underivatized compounds and their methyl and/or trimethylsilyl ether derivatives.

  11. Determination of musty odorants, 2-methylisoborneol and geosmin, in environmental water by headspace solid-phase microextraction and gas chromatography--mass spectrometry.

    Science.gov (United States)

    Saito, Keita; Okamura, Kota; Kataoka, Hiroyuki

    2008-04-01

    A simple and sensitive method for the determination of musty odorants, 2-methylisoborneol (MIB) and geosmin (GSM), in environmental water was developed by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry. MIB and GSM were separated within 10 min using a DB-1 capillary column and detected in the selective ion monitoring mode. HS-SPME using a polydimethylsiloxane/divinylbenzene fiber provided effective sample enrichment, and was carried out by fiber exposition at 70 degrees C for 30 min. Using this method, the calibration curves of MIB and GSM were linear in the range of 0-500 pg/mL, with a correlation coefficient above 0.9977 (n=24). The detection limits (S/N=3) of MIB and GSM were 0.9 and 0.6 pg/mL, respectively. This method was successfully applied to the analysis of environmental water samples without interference peaks.

  12. Characterization of aroma-active compounds in three Chinese Moutai liquors by gas chromatography-olfactometry, gas chromatography-mass spectrometry and sensory evaluation.

    Science.gov (United States)

    Niu, Yunwei; Chen, Xiaomei; Xiao, Zuobing; Ma, Ning; Zhu, Jiancai

    2017-04-01

    The aroma-active compounds in three Chinese Moutai liquors, aged 1 year, 15 years and 30 years were investigated in this study. The aroma compounds were analysed by gas chromatography-olfactometry (GC-O) coupled with gas chromatography-mass spectrometry (GC-MS). A total of 79 aroma compounds were identified. Aroma extract dilution analysis (AEDA) was further employed to identify the aroma-active compounds. A total of 35 aroma-active compounds with flavour dilution (FD) values ≧ 64 simultaneously in three Chinese Moutai liquors were quantitated. Among them, ethyl acetate, ethyl lactate and acetic acid appeared with the highest concentrations. They were all >1000 mg/L. Then, the relationships between the aroma-active compounds and seven sensory attributes were studied.

  13. Prenatal diagnosis of methylmalonic aciduria by measuring methylmalonic acid in dried amniotic fluid on filter paper using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Inoue, Yoshito; Ohse, Morimasa

    2011-06-01

    Methylmalonic aciduria is a common inherited metabolic disorder. Methylmalonic acid (MMA), a key indicator of methylmalonic aciduria, increases in the amniotic fluid of affected fetuses. For prenatal diagnosis, the MMA in amniotic fluid can be measured by stable-isotope dilution gas chromatography-mass spectrometry. Here, we quantified the MMA in cell-free amniotic fluid samples that had been dried on filter paper and transported at ambient temperatures, and compared the results with data obtained from the original amniotic fluid. Our results indicated that the filter paper method was reproducible and accurate enough to be applied to clinical analysis. We also used the filter paper method to screen at-risk fetuses and obtained a clear diagnosis in each case. We conclude that our method enables the prenatal diagnosis of methylmalonic aciduria using practical procedures and a simplified method for transporting the samples.

  14. Applications of Solid-Phase Microextraction and Gas Chromatography/Mass Spectrometry (SPME-GC/MS in the Study of Grape and Wine Volatile Compounds

    Directory of Open Access Journals (Sweden)

    Annarita Panighel

    2014-12-01

    Full Text Available Volatile compounds are responsible for the wine “bouquet”, which is perceived by sniffing the headspace of a glass, and of the aroma component (palate-aroma of the overall flavor, which is perceived on drinking. Grape aroma compounds are transferred to the wine and undergo minimal alteration during fermentation (e.g., monoterpenes and methoxypyrazines; others are precursors of aroma compounds which form in winemaking and during wine aging (e.g., glycosidically-bound volatile compounds and C13-norisoprenoids. Headspace solid phase microextraction (HS-SPME is a fast and simple technique which was developed for analysis of volatile compounds. This review describes some SPME methods coupled with gas chromatography/mass spectrometry (GC/MS used to study the grape and wine volatiles.

  15. Yield effects on 2-methoxy-3-isobutylpyrazine concentration in cabernet sauvignon using a solid phase microextraction gas chromatography/mass spectrometry method.

    Science.gov (United States)

    Chapman, Dawn M; Thorngate, John H; Matthews, Mark A; Guinard, Jean-Xavier; Ebeler, Susan E

    2004-08-25

    A rapid and automated solid phase microextraction (SPME) stable isotope dilution gas chromatography/mass spectrometry (GC-MS) method for 2-methoxy-3-isobutylpyrazine (MIBP) quantification in red wine was developed. Wines with 30% (w/v) NaCl and 2-methoxy-(2)H(3)-3-isobutylpyrazine internal standard were sampled with a 2 cm divinylbenzene/carboxen/poly(dimethylsiloxane) SPME fiber for 30 min at 40 degrees C and analyzed by GC-MS. The method was used to measure MIBP concentrations in Cabernet Sauvignon wines that were produced from six winter pruning treatments over two vintages. MIBP concentrations were significantly negatively correlated with buds per vine. In addition, the MIBP concentration was directly related to sensory vegetal intensity ratings obtained by descriptive analysis.

  16. Immunoaffinity purification of peptide hormones prior to liquid chromatography-mass spectrometry in doping controls.

    Science.gov (United States)

    Thomas, Andreas; Schänzer, Wilhelm; Delahaut, Philippe; Thevis, Mario

    2012-02-01

    For most peptide hormones prohibited in elite sports the concentrations in plasma or urine are very low (pg/mL). Accordingly, hyphenated purification and enrichment steps prior to mass spectrometric detection are required to obtain sufficient doping control assays. Immunoaffinity purification in combination with nano-scale liquid chromatography coupled to high resolution/high accuracy mass spectrometry was found to have the potential of providing the necessary sensitivity and unambiguous specificity to produce reliable results. With the presented methodology 12 prohibited peptides (porcine insulin, Novolog, Apidra, Lantus DesB30-32 metabolite, Humalog and human insulin, Synacthen (synthetic ACTH analogue), luteinizing hormone-releasing hormone (LH-RH), growth hormone releasing hormone (GH-RH(1-29)) and CJC-1295 (GH-RH analogue), LongR(3)-IGF-1 and IFG-1) were simultaneously purified from plasma/serum or urine. With limits of detection for each target compound ranging in the low pg/mL level (urine), the method enables the determination of urinary peptides at physiologically relevant concentrations. For each class of peptides an appropriate antibody and a respective internal standard was implemented ensuring robust analysis conditions. Due to the fast and simple sample preparation procedure (∼25 samples per day) and the fact that all materials are commercial available, the implementation of the methodology to laboratories from other analytical fields (forensics, pharmacokinetic sciences, etc.) is enabled.

  17. Gluten Detection and Speciation by Liquid Chromatography Mass Spectrometry (LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Stephen Lock

    2013-12-01

    Full Text Available Liquid chromatography tandem mass spectrometry (LC-MS/MS has been used historically in proteomics research for over 20 years. However, until recently LC-MS/MS has only been routinely used in food testing for small molecule contaminant detection, for example pesticide and veterinary residue detection, and not as a replacement of microbiological food testing methods, specifically allergen analysis. Over the last couple of years, articles have started to be published which describe the detection of allergens by LC-MS/MS. In this article we will describe how LC-MS/MS can be applied in the area of gluten detection and how it can be used to specifically differentiate the species of gluten used in food, where specific markers for each variety of gluten can be simultaneously acquired and detected at the same time. The article will discuss the effect of variety on the peptide response observed from different wheat grain varieties and will describe the sample preparation protocol which is essential for generating the peptide markers used for speciation.

  18. Mapping of low molecular weight heparins using reversed phase ion pair liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Daoyuan; Chi, Lequan; Jin, Lan; Xu, Xiaohui; Du, Xuzhao; Ji, Shengli; Chi, Lianli

    2014-01-01

    Low molecular weight heparins (LMWHs) are structurally complex, highly sulfated and negatively charged, linear carbohydrate polymers prepared by chemical or enzymatic depolymerization of heparin. They are widely used as anticoagulant drugs possessing better bioavailability, longer half-life, and lower side effects than heparin. Comprehensive structure characterization of LMWHs is important for drug quality assurance, generic drug application, and new drug research and development. However, fully characterization of all oligosaccharide chains in LMWHs is not feasible for current available analytical technologies due to their structure complexity and heterogeneity. Fingerprinting profiling is an efficient way for LMWHs' characterization and comparison. In this work, we present a simple, sensitive, and powerful analytical approach for structural characterization of LMWHs. Two different LMWHs, enoxaparin and nadroparin, were analyzed using reversed phase ion pair electrospray ionization mass spectrometry (RPIP-ESI-MS). More than 200 components were identified, including major structures, minor structures, and process related impurities. This approach is robust for high resolution and complementary fingerprinting analysis of LMWHs.

  19. Online Hydrophobic Interaction Chromatography-Mass Spectrometry for Top-Down Proteomics.

    Science.gov (United States)

    Chen, Bifan; Peng, Ying; Valeja, Santosh G; Xiu, Lichen; Alpert, Andrew J; Ge, Ying

    2016-02-01

    Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.

  20. Determination of polyphenolic compounds by liquid chromatography-mass spectrometry in Thymus species.

    Science.gov (United States)

    Boros, Borbála; Jakabová, Silvia; Dörnyei, Agnes; Horváth, Györgyi; Pluhár, Zsuzsanna; Kilár, Ferenc; Felinger, Attila

    2010-12-17

    Polyphenolic compounds represent a wide group of phytochemicals, including well-known subgroups of phenolic acids, flavonoids, natural dyes, lignans etc., which are produced by plants. These natural bioactive compounds possess a variety of beneficial effects including antioxidant and anticarcinogenic activities, protection against coronary diseases as well as antimicrobial properties. Thymus species have already been reported as sources of different phenolic acids and flavonoids. Moreover, the composition and content of flavonoids in Thymus species play important role as taxonomic markers providing distinction of species. High-performance liquid chromatography (HPLC) coupled with diode array detector (DAD) and on-line mass spectrometry (ESI-MS) method was used for analysis. The method was evaluated for a number of validation characteristics (repeatability and intermediate precision, LOD, LOQ, calibration range, and recovery). The polyphenolic pattern of five native Hungarian Thymus species (T. glabrescens Willd., T. pannonicus All., T. praecox Opiz, T. pulegioides L., and T. serpyllum L.) was characterized. The dominant compound was rosmarinic acid, which ranged between 83.49 μg g(-1) and 1.436 mg g(-1). Other phenolic acids (ferulic acid, caffeic acid and its other derivatives, chlorogenic acid and p-coumaric acids) were present in every examined Thymus species, as well as flavanones: naringenin, eriodictyol and dihydroquercetin; flavones: apigenin and apigenin-7-glucoside, flavonols: quercetin and rutin. The polyphenolic pattern was found to be a useful additional chemotaxonomic tool for classification purposes and determination of the locality of origin.

  1. Quantitation of a recombinant monoclonal antibody in monkey serum by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Liu, Hongcheng; Manuilov, Anton V; Chumsae, Chris; Babineau, Michelle L; Tarcsa, Edit

    2011-07-01

    A method including protein A purification, limited Lys-C digestion, and mass spectrometry analysis was used in the study to quantify a recombinant monoclonal antibody in cynomolgus monkey serum. The same antibody that was isotopically labeled was used as an internal standard. Interferences from serum proteins were first significantly reduced by protein A purification and then by limited Lys-C digestion of protein A bound IgG, including both monkey and the recombinant IgG. Fab fragment of the recombinant human IgG was analyzed directly by LC-MS, while monkey IgG and the Fc fragment of the recombinant human IgG remained bound to protein A resin. Quantitation was achieved by measuring the peak intensity of the Fab from the recombinant human IgG and comparing it to that of the Fab from the stable isotope-labeled internal standard. The results were in good agreement with the values from ELISA. LC-MS can therefore be used as a complementary approach to ELISA to quantify recombinant monoclonal antibodies in serum for pharmacokinetics studies and it can also be used where specific reagents such as antigens are not readily available for ELISA.

  2. Lipid fatty acid profile analyses in liver and serum in rats with nonalcoholic steatohepatitis using improved gas chromatography-mass spectrometry methodology

    Science.gov (United States)

    Fatty acids (FA) are essential components of lipids and exhibit important biological functions. The analyses of FAs are routinely carried out by gas chromatography-mass spectrometry, after multi-step sample preparation. In this study, several key experimental factors were carefully examined, validat...

  3. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    Leeuwen, van Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Feijen, J.; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an -caprolactone (CL

  4. Characterization of the chemical composition of a block copolymer by liquid chromatography/mass spectrometry using atmospheric pressure chemical ionization and electrospray ionization

    NARCIS (Netherlands)

    van Leeuwen, Suze M.; Tan, BoonHua; Grijpma, Dirk W.; Fejen, Jan; Karst, Uwe

    2007-01-01

    Liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in the positive and negative ion modes was used for the characterization of a block copolymer consisting of methoxy poly(ethylene oxide) (mPEO), an epsilon-caprolact

  5. 氟乙酰胺中毒个案的气相色谱-质谱检验%Determination of Fluoroacetamide by Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    郑珲; 张春水; 欧阳津

    2004-01-01

    A method of the determination of fluoroacetamide in a poison case was developed. Fluoroacetamide was extracted from stomach tissue, then was derived by PFBBr and determined by gas chromatography mass spectrometry(GC/MS). The results provided scientific proof for the justice identification.

  6. Hydrolytic degradation of poly(D,L-lactide-co-glycolide 50/50)-di-acrylate network as studied by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Peters, R.; Lebouille, J.; Plum, B.; Schoenmakers, P.; van der Wal, S.

    2011-01-01

    The soluble products of the hydrolytic degradation of photochemically cross-linked poly-(d,l-lactide-co-glycolide 50/50)-di-acrylate film were analysed at different stages to obtain insight into the complex (bio)degradation processes. Liquid chromatography-mass spectrometry analyses have been used t

  7. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  8. Development and validation of liquid chromatography-Mass spectrometry method for the estimation of rifampicin in plasma

    Directory of Open Access Journals (Sweden)

    J S Patil

    2011-01-01

    Full Text Available A selective, rapid and sensitive liquid chromatography-mass spectrometry method was developed for the quantitative estimation of rifampicin in plasma. With phenacetin as internal standard, sample pretreatment involved a one-step extraction with ethyl acetate from plasma. The sample was analyzed using methanol: 2mM ammonium acetate: 80:20 v/v as mobile phase. Chromatographic separation was achieved on a BDS Hypersil Gold C 18 column which was followed by detection with mass spectrometry. Linear calibration curves were obtained in the concentration range of 5.021-1008.315 ng/ml. The inter- and intra-day accuracy values were below 15% at all quality control levels. Percent recoveries for rifampicin at high, middle and low quality control samples was obtained 55.15, 48.65 and 49.62%, respectively and for internal standard was 60.22%. Rifampicin was found stable through all validation parameters. Developed method was found to be simple, precise, accurate and rapid for estimation of rifampicin in plasma. Thus, the method can be employed for routine pharmacokinetic and bioequivalence studies.

  9. [Quantification of acrylamide in foods by gas chromatography-mass spectrometry coupled with pro-column derivatization].

    Science.gov (United States)

    Yang, Sichao; Zhang, Hui; Wang, Junhan; Chen, Fang

    2011-05-01

    The quantification of acrylamide in foods was investigated by gas chromatography-mass spectrometry (GC-MS). In this method, (13)C3-acrylamide was used as an internal standard. The samples were homogenized, defatted with hexane and extracted with ethyl acetate for twice. The derivatization of acrylamide into 2-bromopropenamide (2-BPA) was done using potassium bromide/potassium bromate at 4 degrees C for 90 min. Selective ion monitoring mode was chosen to monitor objective chromatography. This method had a good linearity between 0.05-2.00 mg/kg (r2 = 0.9995), and the limits of detection and quantification were 3 microg/kg and 7 microg/kg, respectively. The recoveries of acrylamide were in the range of 62.7%-65.5%. In order to confirm this GC-MS method, the acrylamide in foods was also determined by high performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS), which had been proved in our laboratory. The concentrations of acrylamide in the samples quantified by GC-MS were slightly higher than those detected by HPLC-MS/MS. This method can be used to quantify acrylamide in normal foods.

  10. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  11. Ion-pairing reversed-phased chromatography/mass spectrometry of heparin

    DEFF Research Database (Denmark)

    Henriksen, Jens; Roepstorff, Peter; Ringborg, Lene Hoffmeyer

    2006-01-01

    not well characterised. In order to further characterise such mixtures, two on-line ion-pairing reverse-phased chromatography electrospray ionisation (ESI) mass spectrometry methods have been developed. One of the systems allows the determination of more than 200 components in a medium molecular weight...

  12. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with dif

  13. Analysis of protein composition of red wine in comparison with rosé and white wines by electrophoresis and high-pressure liquid chromatography-mass spectrometry (HPLC-MS).

    Science.gov (United States)

    Wigand, Petra; Tenzer, Stefan; Schild, Hansjoerg; Decker, Heinz

    2009-05-27

    Wine proteins not only influence wine stability but are also being discussed as potential allergens. Proteins from red, rosé, and white wines were enriched by dialysis and lyophilization followed by separation by SDS-PAGE. Significant differences were detected in the protein compositions of the analyzed wine varieties, and the major protein bands were identified by mass spectrometry after in-gel digestion with trypsin. In German Portugieser red wine, a total of 121 tryptic peptides were identified, which were attributed to 12 grape proteins and 6 proteins derived from yeast. Among the identified constituents are several proteins considered to influence wine stability and previously described potential grape allergens. The pathogenesis-related proteins represent the main proteins in all of the wines, but only some red wines show a band with a molecular mass of 12 kDa, identified as a lipid transfer protein (LTP). The occurrence and distribution of LTP depend on the wine variety.

  14. Combining peak- and chromatogram-based retention time alignment algorithms for multiple chromatography-mass spectrometry datasets

    Directory of Open Access Journals (Sweden)

    Hoffmann Nils

    2012-08-01

    Full Text Available Abstract Background Modern analytical methods in biology and chemistry use separation techniques coupled to sensitive detectors, such as gas chromatography-mass spectrometry (GC-MS and liquid chromatography-mass spectrometry (LC-MS. These hyphenated methods provide high-dimensional data. Comparing such data manually to find corresponding signals is a laborious task, as each experiment usually consists of thousands of individual scans, each containing hundreds or even thousands of distinct signals. In order to allow for successful identification of metabolites or proteins within such data, especially in the context of metabolomics and proteomics, an accurate alignment and matching of corresponding features between two or more experiments is required. Such a matching algorithm should capture fluctuations in the chromatographic system which lead to non-linear distortions on the time axis, as well as systematic changes in recorded intensities. Many different algorithms for the retention time alignment of GC-MS and LC-MS data have been proposed and published, but all of them focus either on aligning previously extracted peak features or on aligning and comparing the complete raw data containing all available features. Results In this paper we introduce two algorithms for retention time alignment of multiple GC-MS datasets: multiple alignment by bidirectional best hits peak assignment and cluster extension (BIPACE and center-star multiple alignment by pairwise partitioned dynamic time warping (CeMAPP-DTW. We show how the similarity-based peak group matching method BIPACE may be used for multiple alignment calculation individually and how it can be used as a preprocessing step for the pairwise alignments performed by CeMAPP-DTW. We evaluate the algorithms individually and in combination on a previously published small GC-MS dataset studying the Leishmania parasite and on a larger GC-MS dataset studying grains of wheat (Triticum aestivum. Conclusions We

  15. Stress degradation study and structure characterization of oxidation degradation product of dexlansoprazole using liquid chromatography-mass spectrometry/time of flight, liquid chromatography-tandem mass spectrometry and nuclear magnetic resonance

    Institute of Scientific and Technical Information of China (English)

    Lakkireddy PRAKASH; M HIMAJA

    2016-01-01

    The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation( ICH)prescribed stress conditions. The drug was found to be more labile under acid,base,neutral,oxidative hydrolysis and thermal stress,while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stability-indicating method. Liquid chromatography-mass spectrometry( LC-MS)analysis was performed for all the deg-radation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools,viz. preparative high performance liquid chromatography( HPLC),liquid chromatography-mass spectrometry/time of flight( LC-MS/TOF),liquid chromatography-tandem mass spectrometry( LC-MS/MS),and nuclear magnetic resonance( NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole,which helps in the development and stability study of active pharmaceutical ingredients and formulated products.

  16. 气-质联用分析雷公藤中萜和生物碱%Gas chromatography-mass spectrometry analysis of terpenes and alkaloids in Tripterygium wilfordii

    Institute of Scientific and Technical Information of China (English)

    郭志峰; 武晓阳; 张晓璇; 高志力

    2013-01-01

    Terpenes and Alkaloids in Tripterygium wilfordii were analyzed using GC-MS. Before alkaloids and terpenes were striped the extracted liquids of Tripterygium wilfordii had been defatted by e-ther, which was separated 130 peaks by gas chromatographic. 58 compounds were identified through their corresponding to the mass spectrometry. These substances included mainly alcohols, aldehydes, acids, esters, ether, terpenoids and alkyls etc. The liquid extracted alkaloids were separated 111 peaks and 40 substances were identified. The relative content of terpenoids and alkaloids were 30% , and others were mainly acid compound and lipid compounds.%采用GC-MS法对雷公藤中的帖和生物碱进行了定性分析.雷公藤提取液先经去脂,再萃取萜和生物碱.去除的脂类经气相色谱分析共分离了130个峰,由它们所对应的质谱,通过谱图检索和谱图解析,鉴定推断出58种化合物.这些物质主要为醇、醛、酸、酯、醚、酮等.雷公藤生物碱提取液色谱分离出111个峰,鉴定出40种物质.其中萜类和生物碱相质量分数30%,其余化合物绝大多数是酸脂类化合物.

  17. Non-targeted metabolomics study for the analysis of chemical compositions in three types of tea by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry%基于气相色谱-质谱联用与液相色谱-质谱联用的非靶向代谢组学用于3类茶叶中化学成分分析

    Institute of Scientific and Technical Information of China (English)

    张磊; 曾仲大; 叶国注; 赵春霞; 路鑫; 许国旺

    2014-01-01

    茶叶中的化学成分是构成其风味特征的物质基础。本研究建立了基于气相色谱-质谱联用和液相色谱-质谱联用的非靶向代谢组学方法。完成预处理及分析条件优化后,使用标准样品考察方法的线性、回收率及重复性,结果表明方法整体稳定且结果可靠。将该方法用于绿茶、乌龙茶和红茶中化学成分的分析。通过超声辅助溶剂提取及气相色谱-质谱联用分析共获得1812个特征峰,而使用加热溶剂提取及液相色谱-质谱联用分析可获得2608个特征峰。结合保留规律及质谱数据库,共定性173种化合物(109种随后经标准样品验证),其中只有9种化合物在上述两类分析中被同时检出,表明方法互补性良好。3类茶叶数据的偏最小二乘判别分析结果表明,三者间存在显著差异。结合模型的变量重要因子( VIP)与非参数检验共筛选出90种化合物,其中包含儿茶素、氨基酸、糖、有机酸和黄酮苷类等众多与茶叶滋味密切相关的化学成分。%Tea is one of the most widely consumed beverages in the world for its benefits to daily life and health. To discover the difference and correlation of chemical compositions in the three typical types of tea,a non-targeted metabolomics method was developed. After the optimization of extraction methods,gas chroma-tography-time-of-flight mass spectrometry and liquid chromatography-quadrupole time-of-flight mass spectrome-try were applied for metabolomics analysis,1 812 and 2 608 features were obtained,respectively. By comparing with the known compounds in public and/or commercial databases,173 compounds were tentatively identified, and 109 of them were experimentally confirmed by standards. Totally,33 tea samples including 12,12 and 9 samples of green,oolong and black tea,respectively,were analyzed by using the above two methods. Multiva-riate analysis,Mann-Whitney U test and hierarchical cluster

  18. Determination of heat purgeable and ambient purgeable volatile organic compounds in water by gas chromatography/mass spectrometry

    Science.gov (United States)

    Rose, Donna L.; Sandstrom, Mark W.; Murtagh, Lucinda K.

    2016-09-08

    Two new analytical methods have been developed by the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) that allow the determination of 37 heat purgeable volatile organic compounds (VOCs) (USGS Method O-4437-16 [NWQL Laboratory Schedule (LS) 4437]) and 49 ambient purgeable VOCs (USGS Method O-4436-16 [NWQL LS 4436]) in unfiltered water. This report documents the procedures and initial performance of both methods. The compounds chosen for inclusion in the methods were determined as having high priority by the USGS National Water-Quality Assessment (NAWQA) Program. Both methods use a purge-and-trap technique with gas chromatography/mass spectrometry. The compounds are extracted from the sample by bubbling helium through a 25-milliliter sample. For the polar and less volatile compounds, the sample is heated at 60 degrees Celsius, whereas the less polar and more volatile compounds are purged using a separate analytical procedure at ambient temperature. The compounds are trapped on a sorbent trap, desorbed into a gas chromatograph/mass spectrometer for separation, and then identified and quantified. Sample preservation is recommended for both methods by adding a 1:1 solution of hydrochloric acid (HCl [1:1]) to water samples to adjust the pH to 2. Analysis within 14 days from sampling is recommended.The heat purgeable method (USGS Method O-4437-16) operates with the mass spectrometer in the simultaneous full scan/selected ion monitoring mode. This method supersedes USGS Method O-4024-03 (NWQL LS 4024). Method detection limits (MDLs) for fumigant compounds 1,2-dibromoethane, 1,2-dichloropropane, 1,2,3-trichloropropane, chloropicrin, and 1,2-dibromo-3-chloropropane range from 0.002 to 0.010 microgram per liter (µg/L). The MDLs for all remaining heat purgeable VOCs range from 0.006 µg/L for tert-butyl methyl ether to 3 µg/L for alpha-terpineol. Calculated holding times indicate that 36 of the 37 heat purgeable VOCs are stable for a minimum of 14 days

  19. Fast analysis of volatile components of Achillea tenuifolia Lam with microwave distillation followed by headspace single-drop microextraction coupled to gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Piryaei, Marzieh; Nazemiyeh, Hossein

    2016-01-01

    This article investigates the effect of microwaves on the amount of volatile compounds Achillea tenuifolia Lam with two methods, headspace single-drop microextraction and microwave-assisted headspace single-drop microextraction (MA-SDME), for the analysis of essential oil. Solvent selection, solvent volume, microwave power, irradiation time and sample mass were optimised by the simplex method.

  20. Assessment of stability of ketamine-xylazine preparations with or without acepromazine using high performance liquid chromatography-mass spectrometry

    Science.gov (United States)

    Dodelet-Devillers, Aurore; Zullian, Chiara; Vachon, Pascal; Beaudry, Francis

    2016-01-01

    The objective of this study was to evaluate the stability of 3 distinct preparations of ketamine and xylazine, with or without acepromazine, stored at room temperature or at 4°C for 1, 2, and 3 mo. Drug concentrations were compared to fresh solutions, using a high performance liquid chromatography-mass spectrometry/selected-ion monitoring (HPLC-MS/SIM) assay. The concentrations of ketamine and xylazine, diluted in physiological saline, did not change over time at room temperature or at 4°C. However, acepromazine concentrations decreased over time when stored at room temperature. In contrast, undiluted ketamine-xylazine preparations gradually decreased in concentration when stored at room temperature. All of the drug concentrations remained above 90% of their original concentration when stored at 4°C. In conclusion, when diluted in physiological saline, ketamine-xylazine cocktails can be stored for 3 mo, whereas undiluted cocktails can lose efficacy over 3 mo at room temperature. Storage at 4°C could preserve drug stability. PMID:26733737

  1. DETERMINATION AND CLASSIFICATION OF VOLATILE COMPOUNDS OF PASTIRMA USING SOLID PHASE MICROEXTRACTION/GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Eda Demirok

    2013-10-01

    Full Text Available Pastırma, a traditional dry cured Turkish meat product, has a great number of specific aroma compounds, which occur as a result of lipid oxidation, protein degradation and formulation of çemen paste. These compounds give characteristic flavor to pastırma and the main objective of this study was to determine the nature of these compounds. Fifty-eight volatile compounds, grouped into nine chemical classes were identified using solid phase microextraction technique (SPME coupled to gas chromatography/mass spectrometry (GC-MS. Aldehydes, mostly lipid oxidation products, were determined as the major chemical group, representing 17.54-78.02% of total volatile compounds. The major volatile aldehyde was hexanal (2.36-55.41%, followed by 2-methyl-2-butenal (0.97-14.69% and then heptanal (0.29-4.77%. Sulfur compounds possibly derived from spices or formed by proteolysis of sulfur-containing amino acids, were the second most abundant group, with concentrations ranging between 6.04 and 50.60%. Other important volatile compounds of pastırma were aliphatic hydrocarbons, aromatic ketones, hydrocarbons, esters, alcohols, acids, terpenes, and furans.

  2. Identifying acetylated lignin units in non-wood fibers using pyrolysis-gas chromatography/mass spectrometry.

    Science.gov (United States)

    del Río, José C; Gutiérrez, Ana; Martínez, Angel T

    2004-01-01

    A series of non-wood plant fibers, namely kenaf, jute, sisal and abaca, have been analyzed upon pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) of the whole material. The pyrolysis products mainly arise from the carbohydrate and lignin moieties of the fibers. The lignin-derived phenols belonged to the p-hydroxyphenylpropanoid (H), guaiacylpropanoid (G) and syringylpropanoid (S) structures, and showed a high S/G ratio of between 2.0 and 5.4, the highest corresponding to kenaf. Among the lignin-derived phenols released, small amounts of sinapyl and coniferyl acetates (in both cis- and trans-forms) were identified for the first time upon Py-GC/MS of lignocellulosic materials. Acetylation of the sinapyl and coniferyl alcohols was at the gamma-position of the side chain. The release of these alcohols derived from intact acetylated lignin units upon pyrolysis seems to indicate that the native lignin in the fibers selected for this study is at least partially acetylated. Sinapyl (and coniferyl) acetates have recently been suggested to be authentic lignin precursors involved in the polymerization of lignin along with the normal sinapyl and coniferyl alcohols. Py-GC/MS will offer a convenient and rapid tool for analyzing naturally acetylated lignins, as well as to screen plant materials for the presence of acetylated units in lignin.

  3. Identification and quantitation of urinary dicarboxylic acids as their dicyclohexyl esters in disease states by gas chromatography mass spectrometry.

    Science.gov (United States)

    Norman, E J; Berry, H K; Denton, M D

    1979-12-01

    Clinical studies were conducted by gas chromatography mass spectrometry selected ion monitoring of urinary dicarboxylic acids as dicyclohexyl esters. The dicyclohexyl esters of the dicarboxylic acids give characteristic electron impact mass spectra suitable for selected ion monitoring. The mass spectra exhibit a prominent acid + 1H ion and an (acid + 1H)-H2O ion for use as quantitating and confirming ions. The cyclohexyl esters are stable for days at room temperature and have excellent chromatographic properties. Dicarboxylic acid quantitation is performed within one hour using only 50 microliter of unpurified urine. A rapid method specifically for methylmalonic acid quantitation is described which has assisted physicians in the diagnosis of pernicious anemia and methylmalonic aciduria. This procedure is applicable for screening urinary organic acids for detection of inborn errors of metabolism. The detection of a child with elevated medium length dicarboxylic acids in the terminal urine specimen is reported. This condition, previously described as an inborn error, is attributed to a terminal event. Finally, an increase in urinary succinic acid paralleling putrescine levels is described during a response to cancer chemotherapy.

  4. Identification of fentanyl metabolites in rat urine by gas chromatography-mass spectrometry with stable-isotope tracers

    Energy Technology Data Exchange (ETDEWEB)

    Goromaru, T.; Matsuura, H.; Furuta, T.; Baba, S.; Yoshimura, N.; Miyawaki, T.; Sameshima, T.

    The metabolites of fentanyl (l), which has been widely used as a neuroleptic analgesic agent, were identified in urine of rats by gas chromatography-mass spectrometry combined with a stable-isotope tracer technique. After the oral administration of an equimolar mixture of l and deuterium-labeled l (l/l-d5), the urinary metabolites were extracted with chloroform at pH 9.0. Extracts were derivatized and analyzed by GC/MS. Metabolites were identified by the presence of doublet ion peaks separated by 5 amu, and chemical structures were established from analyses of fragmentation pathways. The metabolites were identified as 4-N-(N-propionylanilino)-piperidine, 4-N-(N-hydroxypropionylanilino)piperidine, 4-N-(N-propionylanilino) hydroxypiperidine, 1-(2-phenethyl)-4-N-(N-hydroxypropionylanilino)piperidine and 1-(2-phenethyl)-4-N-(N-propionylanilino)hydroxypiperidine. These metabolites, together with unchanged l, were also detected in urine of rats receiving l/l-d5 intravenously, by selected-ion monitoring of the specific cluster ions.

  5. Identification and Quantification of Several Contaminated Compounds in Replacement Liquids of Electronic Cigarettes by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Oh, Jin-Aa; Shin, Ho-Sang

    2015-07-01

    Electronic cigarettes (E-cigarettes) are devices that are refilled with replacement liquids, which normally contain propylene glycol, nicotine and the desired flavor blend. Many consumers suspect that hazardous substances are present in addition to nicotine content. In this study, eight contaminated compounds in 105 replacement liquids from 11 types of E-cigarettes sold in the Republic of Korea were identified and quantified by gas chromatography-mass spectrometry. Diethyl phthalate and diethylhexyl phthalate were detected in concentration ranges of 0.01-1745.20 mg/L (47.6% detection frequency) and 0.06-81.89 mg/L (79.1% detection frequency) in the replacement liquids. Triethylene glycol, tetraethylene glycol and pentaethylene glycol were quantified in concentration ranges of 0.1-19.3 mg/L (10.5% detection frequency), 0.1-30.1 mg/L (12.4% detection frequency) and 0.1-24.9 mg/L (6.7% detection frequency) in the same samples. cis-3-Hexene-1-ol, methyl cinnamate and dodecane were quantified in concentration ranges of 0.03-3267.46 mg/L (70.5% detection frequency), 4.41-637.54 mg/L (6.7% detection frequency) and 0.01-639.96 mg/L (47.6% detection frequency) in the samples.

  6. Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Greyce Kelly Steinhorst Alcantara

    2016-01-01

    Full Text Available Levetiracetam (LEV is an antiepileptic drug that is clinically effective in generalized and partial epilepsy syndromes. The use of this drug has been increasing in clinical practice and intra- or -interindividual variability has been exhibited for special population. For this reason, bioanalytical methods are required for drug monitoring in biological matrices. So this work presents a dispersive liquid-liquid microextraction method followed by gas chromatography-mass spectrometry (DLLME-GC-MS for LEV quantification in human plasma. However, due to the matrix complexity a previous purification step is required. Unlike other pretreatment techniques presented in the literature, for the first time, a procedure employing ultrafiltration tubes Amicon® (10 kDa porous size without organic solvent consumption was developed. GC-MS analyses were carried out using a linear temperature program, capillary fused silica column, and helium as the carrier gas. DLLME optimized parameters were type and volume of extraction and dispersing solvents, salt addition, and vortex agitation time. Under chosen parameters (extraction solvent: chloroform, 130 μL; dispersing solvent: isopropyl alcohol, 400 μL; no salt addition and no vortex agitation time, the method was completely validated and all parameters were in agreement with the literature recommendations. LEV was quantified in patient’s plasma sample using less than 550 μL of organic solvent.

  7. Determination of perfluorinated compounds in packaging materials and textiles using pressurized liquid extraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lv, Gang; Wang, Libing; Liu, Shaocong; Li, Shufen

    2009-03-01

    A simultaneous determination method of trace amounts of perfluorinated compounds, such as perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in packaging materials and textiles, has been developed, using pressurized liquid extraction (PLE) with gas chromatography-mass spectrometry (GC/MS). The perfluorinated compounds were primarily extracted from the samples by a PLE procedure, in which the parameters were optimized by response surface methodology. The solvent was then removed by blowing nitrogen and a silylation step was carried out with N,N-bis(trimethylsilyl)trifluoroacetamide. The silylated compounds were identified and quantified by GC/MS. The proposed method was applied to determine the PFOA and PFOS in polytetrafluoroethylene packaging materials and textiles, where the detection limits of the two compounds were 1.6 and 13.9 ng mL(-1), respectively. The results showed that the concentrations of PFOA and PFOS in the packaging materials and textiles ranged from 17.5 to 45.9 and 33.7 to 81.3 ng g(-1), respectively.

  8. Simultaneous Determination of Tramadol and Its Metabolite in Human Urine by the Gas Chromatography-Mass Spectrometry Method.

    Science.gov (United States)

    Yilmaz, Bilal; Erdem, Ali Fuat

    2015-08-01

    A sensitive and efficient method was developed for determination of tramadol and its metabolite (O-desmethyltramadol) in human urine by gas chromatography-mass spectrometry. Tramadol, O-desmethyltramadol and medazepam (internal standard) were extracted from human urine with a mixture of ethylacetate and diethylether mixture (1 : 1, v/v) at basic pH with liquid-liquid extraction. The calibration curves were linear (r = 0.99) over tramadol and O-desmethyltramadol concentrations ranging from 10 to 200 ng/mL and 7.5 to 300 ng/mL, respectively. The method had an accuracy of >95% and intra- and interday precision (relative standard deviation %) of ≤4.93 and ≤4.62% for tramadol and O-desmethyltramadol, respectively. The extraction recoveries were found to be 94.1 ± 2.91 and 96.3 ± 3.46% for tramadol and O-desmethyltramadol, respectively. The limit of quantification using 0.5 mL human urine was 10 ng/mL for tramadol and 7.5 ng/mL for O-desmethyltramadol. After oral administration of 100 mg of tramadol hydrochloride to a patient, the urinary excretion was monitored during 24 h. About 15% of the dose was excreted as unchanged tramadol.

  9. The anti-atherosclerotic effect of tanshinol borneol ester using fecal metabolomics based on liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Jia, Pu; Wang, Shixiang; Xiao, Chaoni; Yang, Lumeng; Chen, Yongyong; Jiang, Wei; Zheng, Xiaopu; Zhao, Guifang; Zang, Weijin; Zheng, Xiaohui

    2016-02-07

    Tanshinol borneol ester (DBZ) is a novel experimental compound that consists of two chemical structural units from danshensu and borneol. It exhibits efficacious anti-ischemic and anti-atherosclerosis activities in rats. A fecal metabolomics based on Liquid Chromatography-Mass Spectrometry combined with clinical histopathology and blood lipid estimation was employed to assess the efficacy and the metabolic changes caused by administration of DBZ in atherosclerotic rats. There were the typical pathological features of atherosclerosis and significantly increased levels of TC, TG and LDL-C in the atherosclerotic rat group. Nevertheless, atherosclerotic rats administered both DBZ (at a dose of 40 mg kg(-1)) and simvastatin (at a dose of 20 mg kg(-1)) showed good therapeutic effects. The results of the metabolomics studies showed that 55 differential metabolites such as sebacic acid, enterodiol, nonanedioic acid, dodecanedioic acid, cholic acid, 13(S)-HPODE, deoxycholic acid, some phosphatidylglycerol and phosphatidic acids were found, indicating that abnormal metabolism occurred in the pathways of fatty acid oxidation, linoleic acid metabolism, bile acid biosynthesis and glycerophospholipid metabolism in atherosclerotic rats. Compared to those in the model group, the contents of 41 differential metabolites showed a tendency to recover to a healthy level after DBZ administration. Metabolomics studies suggested that DBZ exhibited good treatment efficacy against atherosclerosis by adjusting disturbed metabolic pathways related to atherosclerosis. This study could provide an experimental basis for DBZ's application to act as a candidate drug with anti-atherosclerosis activity.

  10. Dual dispersive liquid-liquid microextraction for determination of phenylpropenes in oils by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsai, Chia-Ju; Li, Jih-Heng; Feng, Chia-Hsien

    2015-09-01

    A novel, simple and quick sample preparation method was developed and used for pre-concentration and extraction of six phenylpropenes, including anethole, estragole, eugenol, methyl eugenol, safrole and myristicin, from oil samples by dual dispersive liquid-liquid microextraction. Gas chromatography-mass spectrometry was used for determination and separation of compounds. Several experimental parameters affecting extraction efficiency were evaluated and optimized, including forward-extractant type and volume, surfactant type and concentration, water volume, and back-extractant type and volume. For all analytes (10-1000ng/mL), the limits of detection (S/N≧3) ranged from 1.0 to 3.0ng/mL; the limits of quantification (S/N≧10) ranged from 2.5 to 10.0ng/mL; and enrichment factors ranged from 3.2 to 37.1 times. Within-run and between-run relative standard deviations (n=6) were less than 2.61% and less than 4.33%, respectively. Linearity was excellent with determination coefficients (r(2)) above 0.9977. The experiments showed that the proposed method is a simple, effective, and environmentally friendly method of analyzing phenylpropenes in oil samples.

  11. Dynamic headspace gas chromatography/mass spectrometry characterization of volatiles produced in fish oil enriched mayonnaise during storage.

    Science.gov (United States)

    Hartvigsen, K; Lund, P; Hansen, L F; Holmer, G

    2000-10-01

    Protection against lipid oxidation and formation of unpleasant fishy and rancid off-flavors in oil-in-water food emulsions, such as fish oil enriched mayonnaise, is difficult to achieve. Volatile profiles from stored mayonnaises with different oil phase compositions were collected using a developed dynamic headspace sampling technique, in which interfering acetic acid was removed in situ with potassium hydroxide, and subsequently 148 volatiles were characterized and monitored by gas chromatography/mass spectrometry. Multivariate statistics showed correlation between the concentration of 62 volatiles and the fish oil and storage parameters, indicating the formation of lipid oxidation products, which impose fishy off-flavors. Further verification was obtained by gas chromatography/olfactometry, by which, among 78 odors, cis-4-heptenal and trans,cis-2,4-heptadienal were detected as distinct fishy notes. In total, 27 volatiles, including 1-penten-3-one, cis-2-penten-1-ol, cis-3-hexenal, cis-4-heptenal, 1-octen-3-one, 1,cis-5-octadien-3-one, 1-octen-3-ol, trans,cis-2, 4-heptadienal, and trans,cis-2,6-nonadienal, were suggested to contribute to the developed unpleasant fishy and rancid off-flavors.

  12. High-performance liquid chromatography-mass spectrometry profiling of phenolic compounds for evaluation of olive oil bitterness and pungency.

    Science.gov (United States)

    Dierkes, Georg; Krieger, Sonja; Dück, Roman; Bongartz, Annette; Schmitz, Oliver J; Hayen, Heiko

    2012-08-08

    Bitterness and pungency are important parameters for olive oil quality. Therefore, two instrumental methods for evaluation of these taste attributes were developed. The first one is based on the photometric measurement of total phenolic compounds content, whereas the second one is based on the semiquantitative evaluation of hydrophilic compounds by high-performance liquid chromatography-mass spectrometry (HPLC-MS). Evaluation of total phenolic compounds content was performed by a modified method for the determination of the K(225) value using a more specific detection based on the pH value dependency of absorbance coefficients of phenols at λ = 274 nm. The latter method was not suitable for correct prediction, because no significant correlation between bitterness/pungency and total phenolic compounds content could be found. For the second method, areas of 25 peaks detected in 54 olive oil samples by a HPLC-MS profiling method were correlated with the bitterness and pungency by partial least-squares regression. Six compounds (oleuropein aglycon, ligstroside aglycon, decarboxymethyl oleuropein aglycon, decarboxymethyl ligstroside aglycon, elenolic acid, and elenolic acid methyl ester) show high correlations to bitterness and pungency. The computed model using these six compounds was able to predict bitterness and pungency of olive oil in the error margin of the sensory evaluation (±0.5) for most of the samples.

  13. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins.

    Science.gov (United States)

    Tang, Yanan; Li, Liang

    2013-08-20

    The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC-MS) with the use of isotope analog standards.

  14. Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    2016-01-01

    Levetiracetam (LEV) is an antiepileptic drug that is clinically effective in generalized and partial epilepsy syndromes. The use of this drug has been increasing in clinical practice and intra- or -interindividual variability has been exhibited for special population. For this reason, bioanalytical methods are required for drug monitoring in biological matrices. So this work presents a dispersive liquid-liquid microextraction method followed by gas chromatography-mass spectrometry (DLLME-GC-MS) for LEV quantification in human plasma. However, due to the matrix complexity a previous purification step is required. Unlike other pretreatment techniques presented in the literature, for the first time, a procedure employing ultrafiltration tubes Amicon® (10 kDa porous size) without organic solvent consumption was developed. GC-MS analyses were carried out using a linear temperature program, capillary fused silica column, and helium as the carrier gas. DLLME optimized parameters were type and volume of extraction and dispersing solvents, salt addition, and vortex agitation time. Under chosen parameters (extraction solvent: chloroform, 130 μL; dispersing solvent: isopropyl alcohol, 400 μL; no salt addition and no vortex agitation time), the method was completely validated and all parameters were in agreement with the literature recommendations. LEV was quantified in patient's plasma sample using less than 550 μL of organic solvent. PMID:27830105

  15. Direct determination of melamine in dairy products by gas chromatography/mass spectrometry with coupled column separation

    Energy Technology Data Exchange (ETDEWEB)

    Xu Xiaomin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou, 310028 (China); Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Ren Yiping [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Zhu Yun [Xinjiang Uygur Autonomous Region Center for Disease Control and Prevention, Urumchi, 830002 (China); Cai Zengxuan; Han Jianlong; Huang Baifen [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310051 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou, 310028 (China)

    2009-09-14

    A coupled capillary column system was developed for the qualitative and quantitative determination of melamine with isotope internal standard in dairy products by gas chromatography/mass spectrometry (GC/MS) without derivatization. A 30 m of DB-5ms ((5%-phenyl)-methylpolysiloxane, 0.25 mm i.d., 0.25 {mu}m df) coupled with a 1.5 m of Innowax (polyethylene glycol, 0.32 mm i.d., 0.25 {mu}m df) by a quartz capillary column connector was introduced as separation column. Three advantages were discussed for the coupled system. The sample was fortified with a ring-labeled {sup 13}C{sub 3}{sup 15}N{sub 3}-melamine as an isotope internal standard and extracted by 1% of trichloroacetic acid aqueous solution. 2.2% of lead acetate solution was then added to deposit protein in the sample matrix. After purification by cation exchange cartridge, the sample solution was directly injected and detected by GC/MS. A six-point calibration curve ranging from 0.05 to 2 mg kg{sup -1} of melamine in sample was used to establish instrument response. The recovery was 93.9-102% with relative standard deviation from 3.1 to 8.7% when isotope internal standard used. The calculated method detection limit was 0.01 mg kg{sup -1}.

  16. [Determination of gomisin A (TJN-101) and its metabolite in rat serum by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Matsuzaki, Y; Ishibashi, E; Koguchi, S; Wakui, Y; Takeda, S; Aburada, M; Oyama, T

    1991-10-01

    Gomisin A (TJN-101) is one of the lignan components isolated from Schisandra Fruits. A high sensitive and precise method for the determination of TJN-101 and its major metabolite (Met. B) in the rat serum was developed by selected ion monitoring (SIM) with gas chromatography-mass spectrometry (GC/MS) using a fused silica capillary column (SPB-1, Supelco). A 100 microliter serum sample was used for the solid phase extraction. The calibration curves of TJN-101 and Met.B both showed a good linearity between 2.0 and 2000.0 ng/ml. The analytical precision (intra-assay, C.V. less than 4.7%), recoveries (98.4 +/- 10.1%), and detection limit (2 ng/ml) of TJN-101 indicated that this system was suited for the determination of TJN-101 in biological fluid. In case of Met.B, the same results as TJN-101, were obtained. After oral administration of TJN-101 at a dose of 10 mg/kg to male rats, the average values of the maximal serum concentration of TJN-101 and Met.B were 1446.1 +/- 131.8 and 317.4 +/- 18.5 ng/ml, respectively. The serum concentrations of these substances could be monitored sufficiently for 8 h after dosing.

  17. [Determination of bisphenol A from toys and food contact materials by derivatization and gas chromatography-mass spectrometry].

    Science.gov (United States)

    Gao, Yonggang; Zhang, Yanyan; Gao, Jianguo; Zhang, Huiling; Zheng, Lisha; Chen, Jing

    2012-10-01

    A method was developed for the determination of bisphenol A (BPA) in toys and food contact materials. The BPA was extracted with Soxhlet extraction method from the sample and reacted with acetic anhydride. The final product was determined by gas chromatography-mass spectrometry (GC-MS). To achieve the optimum derivatization performance, the derivatization time and dosage of derivatization reagent etc. were investigated. Under the optimized experimental conditions, the final product was stable and the peak shape was good. The linearity of the derivative was good in the range of 0.05 to 50 mg/L with the correlation coefficient (r2) above 0.999. The recoveries ranged from 80% to 93% at the spiked levels of 0.05, 1.00, 10.00 mg/kg with the relative standard deviations (RSDs) less than 3.7%. The limit of detection (S/N = 3) was 10 microg/kg. The method is accurate and has high recovery. The method is suitable for the inspection of bisphenol A in toys and food contact materials.

  18. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Maryam Zokaei

    2016-02-01

    Full Text Available Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatization and measurement processes were optimized using the one-factor-at-a-time method. The peak areas were assumed as the GC-MS response to evaluate the extraction efficiency of acrylamide, and optimization for all tests was performed two times. Figures of merit of the proposed method were evaluated. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method. Results: The optimum amounts of effective parameters, including derivatization temperature at 25oC, derivatization time (40 min, xanthydrol volume (40 µL, extracted solvent volume (500 µL and pH=7 were determined. The figures of merit for the proposed method were at the ideal range. The maximum and minimum amounts of acrylamide in the chip samples were also measured. Conclusions: The performance and reliability of proposed method as a simple, efficient and rapid method for determining acrylamide in potato chip samples were demonstrated.

  19. [Structural characterization of Astragalus polysaccharides using partial acid hydrolysis-hydrophilic interaction liquid chromatography-mass spectrometry].

    Science.gov (United States)

    Liang, Tu; Fu, Qing; Xin, Huaxia; Li, Fangbing; Jin, Yu; Liang, Xinmiao

    2014-12-01

    Water-soluble polysaccharides from traditional Chinese medicine (TCM) have properties of broad-spectrum treatment and low toxicity, making them as important components in natural medicines and health products. In order to solve the problem of polysaccharides characterization caused by their complex structures, a "bottom-up" approach was developed to complete the characterization of polysaccharides from Astragalus. Firstly, Astragalus pieces were extracted with hot water and then were precipitated by ethanol to obtain Astragalus polysaccharides. Secondly, a partial acid hydrolysis method was carried out and the effects of time, acid concentration and temperature on hydrolysis were investigated. The degree of hydrolysis increased along with the increase of hydrolysis time and acid concentration. The temperature played a great role in the hydrolysis process. No hydrolysis of the polysaccharides occurred at low temperature, while the polysaccharides were almost hydrolyzed to monosaccharide at high temperature. Under the optimum hydrolysis conditions (4 h, 1.5 mol/L trifluoroacetic acid, and 80 °C), Astragalus polysaccharides were hydrolyzed to characteristic oligosaccharide fragments. At last, a hydrophilic liquid chromatography-mass spectrometry method was used for the separation and structural characterization of the polysaccharide hydrolysates. The results showed that the resulting polysaccharides were mainly 1--> 4 linear glucan, and gluco-oligosaccharides with the degrees of polymerization (DP) of 4 - 11 were obtained after partial acid hydrolysis. The significance of this study is that it is the guidance for the characterization of other TCM polysaccharides.

  20. Applications of Hadamard transform-gas chromatography/mass spectrometry for the detection of hexamethyldisiloxane in a wafer cleanroom.

    Science.gov (United States)

    Cheng, Yuan-Kai; Lin, Cheng-Huang; Kuo, Samuel; Yang, Jonathan; Hsiung, Szu-Yuan; Wang, Jia-Lin

    2012-01-13

    The Hadamard transform-gas chromatography/mass spectrometry (